WorldWideScience

Sample records for lead magnesium niobate-lead

  1. The effects of dopants on the electrical resistivity in lead magnesium niobate multilayer ceramic capacitors

    International Nuclear Information System (INIS)

    Chang, D.D.; Ling, H.C.

    1989-01-01

    Electrical resistivity studies were performed on multilayer ceramic capacitors (MLC) based on lead magnesium niobate and containing dopants of lead titanate, lead zinc niobate, and lead cobalt niobate. The results showed that lead titanate and/or lead zinc niobate had no effect on the electrical resistivity while lead cobalt niobate decreased the resistivity. In samples without lead cobalt niobate, we observed a conduction mechanism with an activation energy of --1 eV, which is commonly observed in barium titanate based dielectrics. This is attributed to ionic conduction via the motion of oxygen vacancies. The increase in conductivity (or decrease in resistivity) resulting from the addition of lead cobalt niobate was rationalized as due to electronic conduction through charge hopping among the cations. This conduction mechanism was characterized by an activation energy of --0.5 eV. Since the activation energy associated with the long-term failure was previously determined by a matrix of temperature and voltage accelerated life tests to be -- 1 eV, they conclude that conduction through charge hopping is not affecting the long-term reliability of these devices

  2. Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications

    International Nuclear Information System (INIS)

    Lau, S.T.; Lam, K.H.; Chan, H.L.W.; Choy, C.L.; Luo, H.S.; Yin, Q.R.; Yin, Z.W.

    2004-01-01

    Ferroelectric lead magnesium niobate-lead titanate (PMN-PT) single crystals with a composition around the rhombohedral-tetragonal morphotropic phase boundary (65 mol% of PMN) were used to fabricate single-element needle-type hydrophones for measuring the spatial and temporal characteristics of medical ultrasonic transducers. PMN-PT single crystal was grown by a modified Bridgman method. Discs (0.5 mm thick) with normal along the direction were cut and then poled by a dc field in the thickness direction. The single crystal has a high relative permittivity (ε r ∼4000) making it appropriate for small area hydrophone applications. Single-element needle-type hydrophones with this material as the sensing element have been fabricated and characterized. The hydrophones have flat frequency response and good receiving sensitivity over certain frequency range in the megahertz region

  3. Phenomenological theory of the dielectric response of lead magnesium niobate and lead scandium tantalate

    International Nuclear Information System (INIS)

    Qian, H.; Bursill, L.A.

    1997-01-01

    The influence of the random field effects originating from charges chemical defects and non-domain textures of the formation and dynamics of polar clusters is analyzed. The spatial distribution of the local fields is not totally random but contains some correlations in direction and strength. Polar clusters are classified to be dynamic or frozen according to their dynamic characteristics in the random fields. The relaxation formula of a dipolar moment in an anisotropic double-well potential is deduced. Two percolation models are introduced, one to account for frustration effects associated with multiple orientations of polar clusters, which results in a broad diffuse dielectric response and the second to account for the case whereby there may be a phase transition to a ferroelectric state. The dielectric permittivity and dissipation factor of the typical relaxors lead magnesium niobate and lead scandium tantalate are predicted as a function of both temperature and frequency, which results are in good agreement with the experimental measurements. 30 refs., 9 figs

  4. Random-field Potts model for the polar domains of lead magnesium niobate and lead scandium tantalate

    Energy Technology Data Exchange (ETDEWEB)

    Qian, H.; Bursill, L.A

    1997-06-01

    A random filed Potts model is used to establish the spatial relationship between the nanoscale distribution of charges chemical defects and nanoscale polar domains for the perovskite-based relaxor materials lead magnesium niobate (PMN) and lead scandium tantalate (PST). The random fields are not set stochastically but are determined initially by the distribution of B-site cations (Mg, Nb) or (Sc, Ta) generated by Monte Carlo NNNI-model simulations for the chemical defects. An appropriate random field Potts model is derived and algorithms developed for a 2D lattice. It is shown that the local fields are strongly correlated with the chemical domain walls and that polar domains as a function of decreasing temperature is simulated for the two cases of PMN and PST. The dynamics of the polar clusters is also discussed. 33 refs., 9 figs.

  5. Observation and analysis of nanodomain textures in dielectric relaxor lead magnesium niobate

    International Nuclear Information System (INIS)

    Bursill, L.A.; Qian, Hua; Peng, Julin; Fan, X.D.

    1995-01-01

    High-resolution (0.2nm) images are used to locate chemical domains occurring with length scales of 1-5nm in the dielectric relaxor lead magnesium niobate (PMN). The experimental HRTEM images are analysed using computer-simulations and image matching in order to clarify and characterize the nature of the chemical ordering. Madelung electrostatic energy calculations are used to rank a set of structural models for possible ordered and disordered distributions of Nb and Mg over the B-sites of perovskite ABO 3 . Next, the chemical domain textures are modelled using next-nearest-neighbour Ising (NNNI) models and Monte Carlo methods. This results in a preferred model for the B-site distribution (the extended NNN-Ising model), which is used for image simulations. Both HRTEM many-beam bright-and dark-field and single-beam dark-field TEM images are obtained and compared with the experimental images. The final result is a realistic atomic model for the Nb, Mg distribution of PMN. 42 refs., 2 tabs., 10 figs

  6. Observation and analysis of nanodomain textures in dielectric relaxor lead magnesium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Bursill, L A; Qian, Hua; Peng, Julin; Fan, X D

    1995-10-01

    High-resolution (0.2nm) images are used to locate chemical domains occurring with length scales of 1-5nm in the dielectric relaxor lead magnesium niobate (PMN). The experimental HRTEM images are analysed using computer-simulations and image matching in order to clarify and characterize the nature of the chemical ordering. Madelung electrostatic energy calculations are used to rank a set of structural models for possible ordered and disordered distributions of Nb and Mg over the B-sites of perovskite ABO{sub 3}. Next, the chemical domain textures are modelled using next-nearest-neighbour Ising (NNNI) models and Monte Carlo methods. This results in a preferred model for the B-site distribution (the extended NNN-Ising model), which is used for image simulations. Both HRTEM many-beam bright-and dark-field and single-beam dark-field TEM images are obtained and compared with the experimental images. The final result is a realistic atomic model for the Nb, Mg distribution of PMN. 42 refs., 2 tabs., 10 figs.

  7. Electric field tuning of magnetism in heterostructure of yttrium iron garnet film/lead magnesium niobate-lead zirconate titanate ceramic

    Science.gov (United States)

    Lian, Jianyun; Ponchel, Freddy; Tiercelin, Nicolas; Chen, Ying; Rémiens, Denis; Lasri, Tuami; Wang, Genshui; Pernod, Philippe; Zhang, Wenbin; Dong, Xianlin

    2018-04-01

    In this paper, the converse magnetoelectric (CME) effect by electric field tuning of magnetization in an original heterostructure composed of a polycrystalline yttrium iron garnet (YIG) film and a lead magnesium niobate-lead zirconate titanate (PMN-PZT) ceramic is presented. The magnetic performances of the YIG films with different thicknesses under a DC electric field applied to the PMN-PZT ceramics and a bias magnetic field are investigated. All the magnetization-electric field curves are found to be in good agreement with the butterfly like strain curve of the PMN-PZT ceramic. Both the sharp deformation of about 2.5‰ of PMN-PZT and the easy magnetization switching of YIG are proposed to be the reasons for the strongest CME interaction in the composite at the small electric coercive field of PMN-PZT (4.1 kV/cm) and the small magnetic coercive field of YIG (20 Oe) where the magnetic susceptibility reaches its maximum value. A remarkable CME coefficient of 3.1 × 10-7 s/m is obtained in the system with a 600 nm-thick YIG film. This heterostructure combining multiferroics and partially magnetized ferrite concepts is able to operate under a small or even in the absence of an external bias magnetic field and is more compact and power efficient than the traditional magnetoelectric devices.

  8. Sol-gel preparation of lead magnesium niobate (PMN) powders and thin films

    Science.gov (United States)

    Boyle, T.J.

    1999-01-12

    A method of preparing a lead magnesium niobium oxide (PMN), Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}, precursor solution by a solvent method wherein a liquid solution of a lead-complex PMN precursor is combined with a liquid solution of a niobium-complex PMN precursor, the combined lead- and niobium-complex liquid solutions are reacted with a magnesium-alkyl solution, forming a PMN precursor solution and a lead-based precipitate, and the precipitate is separated from the reacted liquid PMN precursor solution to form a precipitate-free PMN precursor solution. This precursor solution can be processed to form both ferroelectric powders and thin films. 3 figs.

  9. Giant piezoelectricity in potassium-sodium niobate lead-free ceramics.

    Science.gov (United States)

    Wang, Xiaopeng; Wu, Jiagang; Xiao, Dingquan; Zhu, Jianguo; Cheng, Xiaojing; Zheng, Ting; Zhang, Binyu; Lou, Xiaojie; Wang, Xiangjian

    2014-02-19

    Environment protection and human health concern is the driving force to eliminate the lead from commercial piezoelectric materials. In 2004, Saito et al. [ Saito et al., Nature , 2004 , 432 , 84 . ] developed an alkali niobate-based perovskite solid solution with a peak piezoelectric constant d33 of 416 pC/N when prepared in the textured polycrystalline form, intriguing the enthusiasm of developing high-performance lead-free piezoceramics. Although much attention has been paid on the alkali niobate-based system in the past ten years, no significant breakthrough in its d33 has yet been attained. Here, we report an alkali niobate-based lead-free piezoceramic with the largest d33 of ∼490 pC/N ever reported so far using conventional solid-state method. In addition, this material system also exhibits excellent integrated performance with d33∼390-490 pC/N and TC∼217-304 °C by optimizing the compositions. This giant d33 of the alkali niobate-based lead-free piezoceramics is ascribed to not only the construction of a new rhombohedral-tetragonal phase boundary but also enhanced dielectric and ferroelectric properties. Our finding may pave the way for "lead-free at last".

  10. X-band EPR studies of ferroelectric lead titanate (PT), piezoelectric lead magnesium niobate (PMN), and PMN/PT powders at 10 and 85 K

    International Nuclear Information System (INIS)

    Huang, J.; Fitzgerald, J.J.; Chasteen, N.D.

    1998-01-01

    X-band EPR spectra of lead titanate (PT) and lead magnesium niobate (PMN) powders prepared by different synthetic methods and a PMN/PT powder of the composition 0.9 PMN/01 PT were obtained at 85 and 10 K. Several EPR signals due to adventitious Fe 3+ ion impurities, a signal due to the Ti 3+ ion, and a signal due to the Pb 3+ ion are observed for PT, PMN, and PMN/PT powders. The EPR signals observed at g = 2.0 and 6.0 are assigned to Fe 3+ ions in the B-sites of the perovskite lattice structure of lad titanate with axial symmetry. The EPR signals observed at g = 1.99 and 4.25 are assigned to Fe 3+ ions in the B-sites of the perovskite lattice structure of PMN and 0.9 PMN/0.1 PT materials with cubic and rhombic symmetries, respectively. The sharp EPR signal observed at g = 1.94 is assigned to Ti 3= ion for PT and 0.9 PMN/0.1 PT powders. In addition, a broader EPR signal at g = 2.28--2.30 for PMN obtained by the molten salt method is assigned to axial Pb 3+ ion sites in this PMN material. EPR results obtained here for the e 3+ ions in the B-sites of the PMN materials, in particular, suggest that both cubic and rhombic symmetry sites corresponding to a range of Nb(OMg) x (ONb) 6-x site configurations exist in the PMN. These EPR results indicate that PMN likely exists with partial B-site cation (Mg/Nb) ordering in the perovskite lattice structure

  11. Linear Thermal Expansion Measurements of Lead Magnesium Niobate (PMN) Electroceramic Material for the Terrestrial Planet Finder Coronagraph

    Science.gov (United States)

    Karlmann, Paul B.; Halverson, Peter G.; Peters, Robert D.; Levine, Marie B.; VanBuren, David; Dudik, Matthew J.

    2005-01-01

    Linear thermal expansion measurements of nine samples of Lead Magnesium Niobate (PMN) electroceramic material were recently performed in support of NASA's Terrestrial Planet Finder Coronagraph (TPF-C) mission. The TPF-C mission is a visible light coronagraph designed to look at roughly 50 stars pre- selected as good candidates for possessing earth-like planets. Upon detection of an earth-like planet, TPF-C will analyze the visible-light signature of the planet's atmosphere for specific spectroscopic indicators that life may exist there. With this focus, the project's primary interest in PMN material is for use as a solid-state actuator for deformable mirrors or compensating optics. The nine test samples were machined from three distinct boules of PMN ceramic manufactured by Xinetics Inc. Thermal expansion measurements were performed in 2005 at NASA Jet Propulsion Laboratory (JPL) in their Cryogenic Dilatometer Facility. All measurements were performed in vacuum with sample temperature actively controlled over the range of 270K to 3 10K. Expansion and contraction of the test samples with temperature was measured using a JPL developed interferometric system capable of sub-nanometer accuracy. Presented in this paper is a discussion of the sample configuration, test facilities, test method, data analysis, test results, and future plans.

  12. Potassium Sodium Niobate-Based Lead-Free Piezoelectric Multilayer Ceramics Co-Fired with Nickel Electrodes

    Directory of Open Access Journals (Sweden)

    Shinichiro Kawada

    2015-11-01

    Full Text Available Although lead-free piezoelectric ceramics have been extensively studied, many problems must still be overcome before they are suitable for practical use. One of the main problems is fabricating a multilayer structure, and one solution attracting growing interest is the use of lead-free multilayer piezoelectric ceramics. The paper reviews work that has been done by the authors on lead-free alkali niobate-based multilayer piezoelectric ceramics co-fired with nickel inner electrodes. Nickel inner electrodes have many advantages, such as high electromigration resistance, high interfacial strength with ceramics, and greater cost effectiveness than silver palladium inner electrodes. However, widely used lead zirconate titanate-based ceramics cannot be co-fired with nickel inner electrodes, and silver palladium inner electrodes are usually used for lead zirconate titanate-based piezoelectric ceramics. A possible alternative is lead-free ceramics co-fired with nickel inner electrodes. We have thus been developing lead-free alkali niobate-based multilayer ceramics co-fired with nickel inner electrodes. The normalized electric-field-induced thickness strain (Smax/Emax of a representative alkali niobate-based multilayer ceramic structure with nickel inner electrodes was 360 pm/V, where Smax denotes the maximum strain and Emax denotes the maximum electric field. This value is about half that for the lead zirconate titanate-based ceramics that are widely used. However, a comparable value can be obtained by stacking more ceramic layers with smaller thicknesses. In the paper, the compositional design and process used to co-fire lead-free ceramics with nickel inner electrodes are introduced, and their piezoelectric properties and reliabilities are shown. Recent advances are introduced, and future development is discussed.

  13. Flexible Piezoelectric Touch Sensor by Alignment of Lead-Free Alkaline Niobate Microcubes in PDMS

    NARCIS (Netherlands)

    Deutz, D.B.; Mascarenhas, N.T.; Schelen, J.B.J.; de Leeuw, D.M.; van der Zwaag, S.; Groen, W.A.

    2017-01-01

    A highly sensitive, lead-free, and flexible piezoelectric touch sensor is reported based on composite films of alkaline niobate K0.485Na0.485Li0.03NbO3 (KNLN) powders aligned in a polydimethylsiloxane (PDMS) matrix. KNLN powder is fabricated by

  14. Ridge Waveguide Structures in Magnesium-Doped Lithium Niobate, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this NASA Phase I STTR effort, the feasibility of fabricating isolated ridge waveguides in 5% magnesium-doped lithium niobate (5% MgO:LN) will be established....

  15. Magnesium Diboride Current Leads

    Science.gov (United States)

    Panek, John

    2010-01-01

    A recently discovered superconductor, magnesium diboride (MgB2), can be used to fabricate conducting leads used in cryogenic applications. Dis covered to be superconducting in 2001, MgB2 has the advantage of remaining superconducting at higher temperatures than the previously used material, NbTi. The purpose of these leads is to provide 2 A of electricity to motors located in a 1.3 K environment. The providing environment is a relatively warm 17 K. Requirements for these leads are to survive temperature fluctuations in the 5 K and 11 K heat sinks, and not conduct excessive heat into the 1.3 K environment. Test data showed that each lead in the assembly could conduct 5 A at 4 K, which, when scaled to 17 K, still provided more than the required 2 A. The lead assembly consists of 12 steelclad MgB2 wires, a tensioned Kevlar support, a thermal heat sink interface at 4 K, and base plates. The wires are soldered to heavy copper leads at the 17 K end, and to thin copper-clad NbTi leads at the 1.3 K end. The leads were designed, fabricated, and tested at the Forschungszentrum Karlsruhe - Institut foer Technische Physik before inclusion in Goddard's XRS (X-Ray Spectrometer) instrument onboard the Astro-E2 spacecraft. A key factor is that MgB2 remains superconducting up to 30 K, which means that it does not introduce joule heating as a resistive wire would. Because the required temperature ranges are 1.3-17 K, this provides a large margin of safety. Previous designs lost superconductivity at around 8 K. The disadvantage to MgB2 is that it is a brittle ceramic, and making thin wires from it is challenging. The solution was to encase the leads in thin steel tubes for strength. Previous designs were so brittle as to risk instrument survival. MgB2 leads can be used in any cryogenic application where small currents need to be conducted at below 30 K. Because previous designs would superconduct only at up to 8 K, this new design would be ideal for the 8-30 K range.

  16. Some Structural Properties of the Mixed Lead-Magnesium Hydroxyapatites

    Science.gov (United States)

    Kaaroud, K.; Ben Moussa, S.; Brigui, N.; Badraoui, B.

    2018-02-01

    Lead-magnesium hydroxyapatite solid solutions Pb(10- x)Mg x (PO4)6(OH)2 have been prepared via a hydrothermal process. They were characterized by X-ray powder diffraction, Transmission Electron Microscopy (TEM), chemical and IR spectroscopic analyses. The results of the structural refinement indicated that the limits of lead-magnesium solid solutions ( x ≤ 1.5), a regular decrease of the lattice constant a and a preferential magnesium distribution in site S(I). Through the progressive replacement of Pb2+ ( r = 0.133 nm) by the smaller cation Mg2+ ( r = 0.072 nm), all interatomic distances decrease in accordance with the decrease of the cell parameters. According to what could be expected from the coordinance of the metallic sites S(I) (hexacoordination) and S(II) (heptacoordination), the small magnesium cation preferentially occupies the four sites S(I). The results of the TEM analysis confirm the presence of magnesium in the starting solution and reveals the decrease in the average size of crystals. The IR spectra show the presence of the absorption bands characteristic for the apatite structure.

  17. Influence of Fe{sup 3+} substitution on the dielectric and ferroelectric characteristics of Lead Indium Niobate

    Energy Technology Data Exchange (ETDEWEB)

    Divya, A.S.; Kumar, V., E-mail: vkumar10@yahoo.com

    2015-07-15

    Highlights: • Prepared phase-pure Fe{sup 3+}-substituted Lead Indium Niobate, Pb[(In{sub 0.50−x}Fe{sub x})Nb{sub 0.50}]O{sub 3} by sol–gel method. • Spontaneous Relaxor (R) → Ferroelectric (FE) transition observed for the composition with x = 0.20. • Local structural rearrangement responsible for R → FE transition has been confirmed by Raman spectroscopy. - Abstract: Lead Indium Niobate, Pb(In{sub 0.50}Nb{sub 0.50})O{sub 3} (PIN) is a complex perovskite that exhibits Relaxor (R) characteristics. In this study, we report the synthesis of phase-pure compositions in the system Pb[(In{sub 0.50−x}Fe{sub x})Nb{sub 0.50}]O{sub 3} by sol–gel method and discuss the influence of isovalent substitution of Indium by Iron on the dielectric and ferroelectric characteristics. Spontaneous transition to the Ferroelectric (FE) phase has been observed for the composition having x = 0.20. Local structural rearrangements responsible for R → FE transition have also been studied by Raman spectroscopy and are discussed in detail.

  18. Atomization of magnesium, strontium, barium and lead nitrates on surface of graphite atomizers

    International Nuclear Information System (INIS)

    Nagdaev, V.K.; Pupyshev, A.A.

    1982-01-01

    Modelling of the processes on graphite surface using differential-thermal analysis and graphite core with identification of decomposition products of magnesium, strontium, barium and lead nitrates by X-ray analysis has shown that carbon promotes the formation of strontium, barium and lead carbonates. The obtained temperatures of strontium and barium carbonate decomposition to oxides agree satisfactorily with calculation ones. Magnesium nitrate does not react with carbon. Formation of strontium and barium carbonates results in considerable slowing down of the process of gaseous oxide dissociation. Lead carbonate is unstable and rapidly decomposes to oxide with subsequent reduction to free metal. Formation of magnesium, strontium and barium free atoms is connected with appearance of gaseous oxides in analytical zone. Oxide and free metal lead are present on graphite surface simultaneously

  19. Processing and characterization of lead-free ceramics on the base of sodium-potassium niobate

    Science.gov (United States)

    Politova, E. D.; Golubko, N. V.; Kaleva, G. M.; Mosunov, A. V.; Sadovskaya, N. V.; Stefanovich, S. Yu.; Kiselev, D. A.; Kislyuk, A. M.; Panda, P. K.

    Lead-free sodium-potassium niobate-based piezoelectric materials are most intensively studied in order to replace the widely used Pb-based ones. In this work, the effects of modification of compositions by donor and acceptor dopants in the A- and B-sites of perovskite lattice on structure, dielectric, ferroelectric, and piezoelectric properties of ceramics from Morphotropic Phase Boundary in the (1-x)(K0.5Na0.5)NbO3-xBaTiO3 system and in compositions with x=0.05 and 0.06 additionally doped by Ni3+ cations have been studied.

  20. Processing and characterization of lead-free ceramics on the base of sodium–potassium niobate

    Directory of Open Access Journals (Sweden)

    E. D. Politova

    2018-02-01

    Full Text Available Lead-free sodium–potassium niobate-based piezoelectric materials are most intensively studied in order to replace the widely used Pb-based ones. In this work, the effects of modification of compositions by donor and acceptor dopants in the A- and B-sites of perovskite lattice on structure, dielectric, ferroelectric, and piezoelectric properties of ceramics from Morphotropic Phase Boundary in the (1−x(K0.5Na0.5NbO3–xBaTiO3 system and in compositions with x=0.05 and 0.06 additionally doped by Ni3+ cations have been studied.

  1. Radiation-damage-assisted ferroelectric domain structuring in magnesium-doped lithium niobate

    Science.gov (United States)

    Jentjens, L.; Peithmann, K.; Maier, K.; Steigerwald, H.; Jungk, T.

    2009-06-01

    Irradiation of 5% magnesium-doped lithium niobate crystals (LiNbO3:Mg) with high-energy, low-mass 3He ions, which are transmitted through the crystal, changes the domain reversal properties of the material. This enables easier domain engineering compared to non-irradiated material and assists the formation of small-sized periodically poled domains in LiNbO3:Mg. Periodic domain structures exhibiting a width of ≈520 nm are obtained in radiation-damaged sections of the crystals. The ferroelectric poling behavior between irradiated and non-treated material is compared.

  2. Ridge Waveguide Structures in Magnesium-Doped Lithium Niobate

    Science.gov (United States)

    Himmer, Phillip; Battle, Philip; Suckow, William; Switzer, Greg

    2011-01-01

    This work proposes to establish the feasibility of fabricating isolated ridge waveguides in 5% MgO:LN. Ridge waveguides in MgO:LN will significantly improve power handling and conversion efficiency, increase photonic component integration, and be well suited to spacebased applications. The key innovation in this effort is to combine recently available large, high-photorefractive-damage-threshold, z-cut 5% MgO:LN with novel ridge fabrication techniques to achieve high-optical power, low-cost, high-volume manufacturing of frequency conversion structures. The proposed ridge waveguide structure should maintain the characteristics of the periodically poled bulk substrate, allowing for the efficient frequency conversion typical of waveguides and the high optical damage threshold and long lifetimes typical of the 5% doped bulk substrate. The low cost and large area of 5% MgO:LN wafers, and the improved performance of the proposed ridge waveguide structure, will enhance existing measurement capabilities as well as reduce the resources required to achieve high-performance specifications. The purpose of the ridge waveguides in MgO:LN is to provide platform technology that will improve optical power handling and conversion efficiency compared to existing waveguide technology. The proposed ridge waveguide is produced using standard microfabrication techniques. The approach is enabled by recent advances in inductively coupled plasma etchers and chemical mechanical planarization techniques. In conjunction with wafer bonding, this fabrication methodology can be used to create arbitrarily shaped waveguides allowing complex optical circuits to be engineered in nonlinear optical materials such as magnesium doped lithium niobate. Researchers here have identified NLO (nonlinear optical) ridge waveguide structures as having suitable value to be the leading frequency conversion structures. Its value is based on having the low-cost fabrication necessary to satisfy the challenging pricing

  3. Piezoelectric and ferroelectric properties of lead-free niobium-rich potassium lithium tantalate niobate single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun, E-mail: lijuna@hit.edu.cn [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); Li, Yang [Department of chemistry, Harbin Institute of Technology, Harbin 150001 (China); Zhou, Zhongxiang [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); Guo, Ruyan; Bhalla, Amar S. [Multifunctional Electronic Materials and Device Research Lab, Department of Electrical and Computer Engineering, The University of Texas at San Antonio, San Antonio 78249 (United States)

    2014-01-01

    Graphical abstract: - Highlights: • Lead-free K{sub 0.95}Li{sub 0.05}Ta{sub 1−x}Nb{sub x}O{sub 3} single crystals were grown using the top-seeded melt growth method. • The piezoelectric and ferroelectric properties of as-grown crystals were systematically investigated. • The piezoelectric properties are very attractive, e.g. for x = 0.60 composition, k{sub t} ≈ 70%, k{sub 31} ≈ 70%, k{sub 33} ≈ 77%, d{sub 31} ≈ 230 pC/N, d{sub 33} ≈ 600 pC/N. • The coercive fields of P–E hysteresis loops are quite small, about or less than 1 kV/mm. - Abstract: Lead-free potassium lithium tantalate niobate single crystals with the composition of K{sub 0.95}Li{sub 0.05}Ta{sub 1−x}Nb{sub x}O{sub 3} (abbreviated as KLTN, x = 0.51, 0.60, 0.69, 0.78) were grown using the top-seeded melt growth method. Their piezoelectric and ferroelectric properties in as-grown crystals have been systematically investigated. The phase transitions and Curie temperatures were determined from dielectric and pyroelectric measurements. Piezoelectric coefficients and electromechanical coupling factors in thickness mode, length-extensional mode and longitudinal mode were obtained. The piezoelectric properties are very attractive, e.g. for x = 0.60 composition, k{sub t} ≈ 70%, k{sub 31} ≈ 70%, k{sub 33} ≈ 77%, d{sub 31} ≈ 230 pC/N, d{sub 33} ≈ 600 pC/N are comparable to the lead-based PZT composition. The polarization versus electric field hysteresis loops show saturated shapes. In short, lead-free niobium-rich KLTN system possesses comparable properties to those in important lead-based piezoelectric material nowadays.

  4. Lead-free piezoceramics.

    Science.gov (United States)

    Saito, Yasuyoshi; Takao, Hisaaki; Tani, Toshihiko; Nonoyama, Tatsuhiko; Takatori, Kazumasa; Homma, Takahiko; Nagaya, Toshiatsu; Nakamura, Masaya

    2004-11-04

    Lead has recently been expelled from many commercial applications and materials (for example, from solder, glass and pottery glaze) owing to concerns regarding its toxicity. Lead zirconium titanate (PZT) ceramics are high-performance piezoelectric materials, which are widely used in sensors, actuators and other electronic devices; they contain more than 60 weight per cent lead. Although there has been a concerted effort to develop lead-free piezoelectric ceramics, no effective alternative to PZT has yet been found. Here we report a lead-free piezoelectric ceramic with an electric-field-induced strain comparable to typical actuator-grade PZT. We achieved this through the combination of the discovery of a morphotropic phase boundary in an alkaline niobate-based perovskite solid solution, and the development of a processing route leading to highly textured polycrystals. The ceramic exhibits a piezoelectric constant d33 (the induced charge per unit force applied in the same direction) of above 300 picocoulombs per newton (pC N(-1)), and texturing the material leads to a peak d33 of 416 pC N(-1). The textured material also exhibits temperature-independent field-induced strain characteristics.

  5. Electromechanical properties of engineered lead free potassium sodium niobate based materials =

    Science.gov (United States)

    Rafiq, Muhammad Asif

    K0.5Na0.5NbO3 (KNN), is the most promising lead free material for substituting lead zirconate titanate (PZT) which is still the market leader used for sensors and actuators. To make KNN a real competitor, it is necessary to understand and to improve its properties. This goal is pursued in the present work via different approaches aiming to study KNN intrinsic properties and then to identify appropriate strategies like doping and texturing for designing better KNN materials for an intended application. Hence, polycrystalline KNN ceramics (undoped, non-stoichiometric; NST and doped), high-quality KNN single crystals and textured KNN based ceramics were successfully synthesized and characterized in this work. Polycrystalline undoped, non-stoichiometric (NST) and Mn doped KNN ceramics were prepared by conventional ceramic processing. Structure, microstructure and electrical properties were measured. It was observed that the window for mono-phasic compositions was very narrow for both NST ceramics and Mn doped ceramics. For NST ceramics the variation of A/B ratio influenced the polarization (P-E) hysteresis loop and better piezoelectric and dielectric responses could be found for small stoichiometry deviations (A/B = 0.97). Regarding Mn doping, as compared to undoped KNN which showed leaky polarization (P-E) hysteresis loops, B-site Mn doped ceramics showed a well saturated, less-leaky hysteresis loop and a significant properties improvement. Impedance spectroscopy was used to assess the role of Mn and a relation between charge transport - defects and ferroelectric response in K0.5Na0.5NbO3 (KNN) and Mn doped KNN ceramics could be established. At room temperature the conduction in KNN which is associated with holes transport is suppressed by Mn doping. Hence Mn addition increases the resistivity of the ceramic, which proved to be very helpful for improving the saturation of the P-E loop. At high temperatures the conduction is dominated by the motion of ionized oxygen

  6. Lead-free piezoelectric materials and ultrasonic transducers for medical imaging

    Directory of Open Access Journals (Sweden)

    Elaheh Taghaddos

    2015-06-01

    Full Text Available Piezoelectric materials have been vastly used in ultrasonic transducers for medical imaging. In this paper, firstly, the most promising lead-free compositions with perovskite structure for medical imaging applications have been reviewed. The electromechanical properties of various lead-free ceramics, composites, and single crystals based on barium titanate, bismuth sodium titanate, potassium sodium niobate, and lithium niobate are presented. Then, fundamental principles and design considerations of ultrasonic transducers are briefly described. Finally, recent developments in lead-free ultrasonic probes are discussed and their acoustic performance is compared to lead-based transducers. Focused transducers with different beam focusing methods such as lens focusing and mechanical shaping are explained. Additionally, acoustic characteristics of lead-free probes including the pulse-echo results as well as their imaging capabilities for various applications such as phantom imaging, in vitro intravascular ultrasound imaging of swine aorta, and in vivo or ex vivo imaging of human eyes and skin are reviewed.

  7. The determination of lead, zinc, and magnesium in dolomite and its benefication products by use of x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Jacobs, J.J.

    1985-01-01

    An investigation was undertaken on the development of fast, simple, and accurate methods of analysis for lead and zinc in tailings and middlings from dolomite, and for lead, zinc, and magnesium in concentrates obtained from dolomite. A pressed-powder technique and X-ray-fluorescence spectrometry (XRFS) were used. Good agreement was found between the XRFS values for lead and zinc in low concentrations and the values obtained by other techniques of analysis when the calibration for the XRFS method was effected by the use of synthetic standards comprising lead and zinc oxides in a dolomite matrix. For high concentrations of the analytes, all the oxides and sulphides of lead and zinc in the samples had to be converted to the sulphate form, and a matrix correction had to be applied to the assigned values of the oxide calibration standards. The lower limits of detection for lead, zinc, and magnesium were 0,004, 0,003, and 0,18 per cent respectively. The recommended methods are detailed in two appendices

  8. Activity of Catalase (CAT, ALT and AST in Different Organs of Swiss Albino Mice Treated with Lead Acetate, Vitamin C and Magnesium-L-Threonate

    Directory of Open Access Journals (Sweden)

    Ilir Nazmi Mazreku

    2017-11-01

    Full Text Available Introduction: Lead is a natural element with toxic properties and is widespread in the environment. Lead toxicity is associated with generation of reactive oxygen and nitrogen species and consumption of antioxidants elements (vitamin E and C, glutathione, thioredoxin and lipoic acid, melatonin, carotenoids and natural flavonoids in the cell, and unbalancing oxidantsantioxidants levels. Aim: To evaluate the effects of different chemical combinations (lead acetate, Vitamin C and Magnesium-L-threonate on antioxidant enzyme activity (catalase-CAT of liver, kidney, spleen, pancreas and brain, and serum transaminases [Serum Alanine Transaminase (ALT and Serum Aspartate Transaminase (AST]. Materials and Methods: Experimental animals (49 male Mus musculus-swiss albino mice were separated into five different groups. The first group was used as a control, hence the other four groups were treated with sub-lethal doses (90 mg/kg of lead acetate (group 2, lead acetate (90 mg/kg and Vitamin C dose 40mg/kg (group 3, lead acetate (90 mg/kg and Magnesium-Lthreonate dose 100 mg/kg (group 4 and only with MagnesiumL-threonate dose 100 mg/kg (group 5, during the treatment period (40 days. Blood samples were taken from the facial vein and used for transaminase analysis. Organ tissue was collected after euthanizing anaesthetized animals with neck dislocation technique. Results: The results showed that lead acetate treatment has caused significant elevation in the activity of AST (group 2 and 3 and ALT (group 3. Also, CAT activity was significantly (p<0.05 increased in groups treated with lead acetate (liver, pancreas, kidney and brain but not in spleen. Treatment of lead intoxicated groups with Vitamin C and Magnesium L-threonate increased significantly CAT activity in brain. Conclusion: Lead effects by interacting with different molecular systems and increasing enzyme activity (CAT, ALT and AST. Effects on CAT activity of Magnesium-L-threonate and Vitamin C treatment

  9. Temperature behavior of electrical properties of high-k lead-magnesium-niobium titanate thin-films

    Energy Technology Data Exchange (ETDEWEB)

    Chen Wenbin, E-mail: cwb0201@163.com [Electromechanical Engineering College, Guilin University of Electronic Technology (China); McCarthy, Kevin G. [Department of Electrical and Electronic Engineering, University College Cork (Ireland); Copuroglu, Mehmet; O' Brien, Shane; Winfield, Richard; Mathewson, Alan [Tyndall National Institute, University College Cork (Ireland)

    2012-05-01

    This paper reports on the temperature dependence of the electrical properties of high-k lead-magnesium-niobium titanate thin films processed with different compositions (with and without nanoparticles) and with different annealing temperatures (450 Degree-Sign C and 750 Degree-Sign C). These characterization results support the ongoing investigation of the material's electrical properties which are necessary before the dielectric can be used in silicon-based IC applications.

  10. Trace elements studies on Karachi populations, part III: blood copper, zinc, magnesium and lead levels in psychiatric patients with disturbed behavior

    International Nuclear Information System (INIS)

    Manser, W.T.

    1989-01-01

    Blood levels of copper, zinc, magnesium and lead were determined in 29 males and 15 females suffering from disturbed behavior. As far as we could ascertain they were under no medication and belong to low income groups. Male patients had significantly higher levels than female patients for zinc but there was no sexual difference for magnesium or cooper. In patients copper and lead levels were higher than for normals, but no difference could be found for Mg and Zn. At least one metal abnormality was observed in 19 of the males and 9 (60.0%) of the female patients. (author)

  11. Determination of temperature dependency of material parameters for lead-free alkali niobate piezoceramics by the inverse method

    Directory of Open Access Journals (Sweden)

    K. Ogo

    2016-06-01

    Full Text Available Sodium potassium niobate (NKN piezoceramics have been paid much attention as lead-free piezoelectric materials in high temperature devices because of their high Curie temperature. The temperature dependency of their material parameters, however, has not been determined in detail up to now. For this purpose, we exploit the so-called Inverse Method denoting a simulation-based characterization approach. Compared with other characterization methods, the Inverse Method requires only one sample shape of the piezoceramic material and has further decisive advantages. The identification of material parameters showed that NKN is mechanically softer in shear direction compared with lead zirconate titanate (PZT at room temperature. The temperature dependency of the material parameters of NKN was evaluated in the temperature range from 30 °C to 150 °C. As a result, we figured out that dielectric constants and piezoelectric constants show a monotonous and isotropic increment with increasing temperature. On the other hand, elastic stiffness constant c 44 E of NKN significantly decreased in contrast to other elastic stiffness constants. It could be revealed that the decrement of c 44 E is associated with an orthorhombic-tetragonal phase transition. Furthermore, ratio of elastic compliance constants s 44 E / s 33 E exhibited similar temperature dependent behavior to the ratio of piezoelectric constants d15/d33. It is suspected that mechanical softness in shear direction is one origin of the large piezoelectric shear mode of NKN. Our results show that NKN are suitable for high temperature devices, and that the Inverse Method should be a helpful approach to characterize material parameters under their practical operating conditions for NKN.

  12. Preparation of Lead Magnesium Niobate-Lead Zirconate Titanate Films and Their Crystallization Behaviors

    International Nuclear Information System (INIS)

    Tursiloadi, Silvester

    2002-01-01

    The thin films with composition near morpotropic phase boundary (MPB) of the system xPb(Mg 1 /3, Nb 2 /3) O 3 -yPbTiO 3 -zPbZrO 3 (x = 0-0.35, y = 0.47 and z = 0.53), were prepared by sol-gel method. The starting materials were consisted of Pb(iso-OC 3 H 7 ) 2 , Zr(n-OC 4 H 9 ) 4 , Ti(iso-OC 3 H 7 ) 4 , Mg(CH 3 COO) 2 4H 2 O and Nb(OC 2 H 5 ) 5 . The l-propanol was used as solvent. The concentration of PMN-PT-PZ in coating solution was 0.7 M, and the pH of the solution was 4.5. The thin films were prepared by dip coating and spin coating. The crystallization behaviors of the PMN-PT-PZ thin films showed that the formation of perovskite phase at low temperature becomes difficult with increasing the content of PMN. The amounts of pyrochlore and perovskite phase in PMN-PT-PZ films depended on the heating temperatures, and PMN contents. Single-phase perovskite was found for the coated films containing 0 and 12.5 mol% after calculating at 600 o C, 21 mol% after calculating at 700 o C, and 30 mol% after calculating at 750 o C. Single-phase perovskite of coated films will never be found when the content of PMN was 35 mol%

  13. Progress in engineering high strain lead-free piezoelectric ceramics

    International Nuclear Information System (INIS)

    Leontsev, Serhiy O; Eitel, Richard E

    2010-01-01

    Environmental concerns are strongly driving the need to replace the lead-based piezoelectric materials currently employed as multilayer actuators. The current review describes both compositional and structural engineering approaches to achieve enhanced piezoelectric properties in lead-free materials. The review of the compositional engineering approach focuses on compositional tuning of the properties and phase behavior in three promising families of lead-free perovskite ferroelectrics: the titanate, alkaline niobate and bismuth perovskites and their solid solutions. The 'structural engineering' approaches focus instead on optimization of microstructural features including grain size, grain orientation or texture, ferroelectric domain size and electrical bias field as potential paths to induce large piezoelectric properties in lead-free piezoceramics. It is suggested that a combination of both compositional and novel structural engineering approaches will be required in order to realize viable lead-free alternatives to current lead-based materials for piezoelectric actuator applications. (topical review)

  14. Progress in engineering high strain lead-free piezoelectric ceramics

    Science.gov (United States)

    Leontsev, Serhiy O; Eitel, Richard E

    2010-01-01

    Environmental concerns are strongly driving the need to replace the lead-based piezoelectric materials currently employed as multilayer actuators. The current review describes both compositional and structural engineering approaches to achieve enhanced piezoelectric properties in lead-free materials. The review of the compositional engineering approach focuses on compositional tuning of the properties and phase behavior in three promising families of lead-free perovskite ferroelectrics: the titanate, alkaline niobate and bismuth perovskites and their solid solutions. The ‘structural engineering’ approaches focus instead on optimization of microstructural features including grain size, grain orientation or texture, ferroelectric domain size and electrical bias field as potential paths to induce large piezoelectric properties in lead-free piezoceramics. It is suggested that a combination of both compositional and novel structural engineering approaches will be required in order to realize viable lead-free alternatives to current lead-based materials for piezoelectric actuator applications. PMID:27877343

  15. Texturation of lead-free BaTiO3-based piezoelectric ceramics

    OpenAIRE

    Ngueteu-Kamlo , A; Levassort , F; Pham Thi , M; Marchet , Pascal

    2014-01-01

    International audience; Nowadays, piezoelectric ceramics are integrated in a wide range of devices, in particular in ultrasonic applications (underwater sonar systems, medical imaging, non-destructive testing…). Most of them use Pb(Zr,Ti)O3 (PZT). However, due to health care and environmental problems, lead content must be reduced in such applications [1]. Recent reviews demonstrated that few lead-free materials families can be considered: the alkaline-niobates (K0.5Na0.5NbO3), the alkaline-b...

  16. Optical cleaning of lithium niobate crystals

    International Nuclear Information System (INIS)

    Koesters, Michael

    2010-01-01

    An all-optical method for the removal of photoexcitable electrons from photorefractive centers to get rid of optical damage in lithium niobate crystals is presented, the so-called ''optical cleaning''. The method combines the photovoltaic drift of electrons with ionic charge compensation at sufficiently high temperatures of about 180 C. Optimum choice of the light pattern plus heat dramatically decreases the concentration of photoexcitable electrons in the exposed region leading to a suppression of optical damage. Experiments with slightly iron-doped lithium niobate crystals have shown an increase of the threshold for optical damage of more than 1000 compared to those of untreated crystals. (orig.)

  17. Optical cleaning of lithium niobate crystals

    Energy Technology Data Exchange (ETDEWEB)

    Koesters, Michael

    2010-01-15

    An all-optical method for the removal of photoexcitable electrons from photorefractive centers to get rid of optical damage in lithium niobate crystals is presented, the so-called ''optical cleaning''. The method combines the photovoltaic drift of electrons with ionic charge compensation at sufficiently high temperatures of about 180 C. Optimum choice of the light pattern plus heat dramatically decreases the concentration of photoexcitable electrons in the exposed region leading to a suppression of optical damage. Experiments with slightly iron-doped lithium niobate crystals have shown an increase of the threshold for optical damage of more than 1000 compared to those of untreated crystals. (orig.)

  18. TOPICAL REVIEW: Progress in engineering high strain lead-free piezoelectric ceramics

    Science.gov (United States)

    Leontsev, Serhiy O.; Eitel, Richard E.

    2010-08-01

    Environmental concerns are strongly driving the need to replace the lead-based piezoelectric materials currently employed as multilayer actuators. The current review describes both compositional and structural engineering approaches to achieve enhanced piezoelectric properties in lead-free materials. The review of the compositional engineering approach focuses on compositional tuning of the properties and phase behavior in three promising families of lead-free perovskite ferroelectrics: the titanate, alkaline niobate and bismuth perovskites and their solid solutions. The 'structural engineering' approaches focus instead on optimization of microstructural features including grain size, grain orientation or texture, ferroelectric domain size and electrical bias field as potential paths to induce large piezoelectric properties in lead-free piezoceramics. It is suggested that a combination of both compositional and novel structural engineering approaches will be required in order to realize viable lead-free alternatives to current lead-based materials for piezoelectric actuator applications.

  19. Study of lead free ferroelectrics using overlay technique on thick film microstrip ring resonator

    Directory of Open Access Journals (Sweden)

    Shridhar N. Mathad

    2016-03-01

    Full Text Available The lead free ferroelectrics, strontium barium niobates, were synthesized via the low cost solid state reaction method and their fritless thick films were fabricated by screen printing technique on alumina substrate. The X band response (complex permittivity at very high frequencies of Ag thick film microstrip ring resonator perturbed with strontium barium niobates (SrxBa1-xNb2O6 in form of bulk and thick film was measured. A new approach for determination of complex permittivity (ε′ and ε′′ in the frequency range 8–12 GHz, using perturbation of Ag thick film microstrip ring resonator (MSRR, was applied for both bulk and thick film of strontium barium niobates (SrxBa1-xNb2O6. The microwave conductivity of the bulk and thick film lie in the range from 1.779 S/cm to 2.874 S/cm and 1.364 S/cm to 2.296 S/cm, respectively. The penetration depth of microwave in strontium barium niobates is also reported.

  20. Mechanical Pre-Stressing a Transducer through a Negative DC Biasing Field

    Science.gov (United States)

    2017-04-21

    Undersea Warfare Center ONR Office of Naval Research PMN-PT Lead Magnesium Niobate-Lead Titanate PZT Lead Zirconate Titanate 1 MECHANICAL...stiff material (such as aluminum or magnesium ). With the ceramic stack sandwiched between the two masses, a two degree-of-freedom system is...Aerotech, Inc., Pittsburgh, PA. Sayer, M., Judd, B.A., EI -Assal, K., Prasad, E., “Poling of Piezoelectric Ceramics,” Journal of the Canadian

  1. Towards bio monitoring of toxic (lead) and essential elements in ...

    African Journals Online (AJOL)

    The degree of lead intoxication in all the children studied was low; The established reference intervals for Cu, Zn, Ca and Mg provide an important guidance for the reasonable supplementation of essential elements during different age groups. Keywords: prenatal biomonitoring, copper, zinc, calcium, magnesium, iron, lead ...

  2. Gamma radiation effects on photorefractive and photoelectric properties of lithium niobate crystals

    Energy Technology Data Exchange (ETDEWEB)

    Vartanyan, Eh.S.; Ovsepyan, R.K.; Pogosyan, A.R.; Timofeev, A.L.

    1984-08-01

    Investigations into the gamma radiation effect on the photorefractive aned photoelectric properties of lithium niobate crystals have been carried out for the first time. Gamma irradiation has been found to lead to an increase in the photorefractive sensitivity. The effect of optical decoloration has been discovered for the first time along with photorelaxation currents resulting from radiation center decay under the action of light. It has been shown that an increase of photorefractive sensitivity in gamma-irradiated lithium niobate crystals is caused by a new photorefraction mechanism - photorelaxation currents.

  3. Nano-Structured Magnesium Oxide Coated Iron Ore: Its Application to the Remediation of Wastewater Containing Lead.

    Science.gov (United States)

    Nagarajah, Ranjini; Jang, Min; Pichiah, Saravanan; Cho, Jongman; Snyder, Shane A

    2015-12-01

    Magnetically separable nano-structured magnesium oxide coated iron ore (IO(MgO)) was prepared using environmentally benign chemicals, such as iron ore (IO), magnesium(II) nitrate hexahydrate [Mg(NO3)2 x 6H2O] and urea; via an easy and fast preparation method. The lO(MgO) was characterized using X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS) and alternating gradient magnetometer (AGM) analyses. The isotherm and kinetic studies indicated that lO(MgO) has a comparably higher Langmuir constant (K(L), 1.69 L mg(-1)) and maximum sorption capacity (33.9 mg g(-1)) for lead (Pb) than other inorganic media. Based on MgO amount, the removal capacity of Pb by IO(MgO) was 2,724 mg Pb (g MgO)(-1), which was higher than that (1,980 mg g(-1)) for flowerlike magnesium oxide nanostructures reported by Cao et al. The kinetics, FE-SEM, elemental mapping and XRD results revealed that the substitution followed by precipitation was identified as the mechanism of Pb removal and plumbophyllite (Pb2Si4O10 x H2O) was the precipitated phase of Pb. A leaching test revealed that IOMgO) had negligible concentrations of leached Fe at pH 4-9. Since the base material, IO, is cheap and easily available, lO(MgO) could be produced in massive amounts and used for remediation of wastewater containing heavy metals, applying simple and fast magnetic separation.

  4. Potential containment materials for liquid-lead and lead-bismuth eutectic spallation neutron source

    International Nuclear Information System (INIS)

    Park, J.J.; Butt, D.P.; Beard, C.A.

    1997-11-01

    Lead (Pb) and lead-bismuth eutectic (44Pb-56Bi) have been the two primary candidate liquid-metal target materials for the production of spallation neutrons. Selection of a container material for the liquid-metal target will greatly affect the lifetime and safety of the target subsystem. For the lead target, niobium-1 (wt%) zirconium (Nb-1Zr) is a candidate containment material for liquid lead, but its poor oxidation resistance has been a major concern. The oxidation rate of Nb-1Zr was studied based on the calculations of thickness loss due to oxidation. According to these calculations, it appeared that uncoated Nb-1Zr may be used for a one-year operation at 900 C at P O 2 = 1 x 10 -6 torr, but the same material may not be used in argon with 5-ppm oxygen. Coating technologies to reduce the oxidation of Nb-1Zr are reviewed, as are other candidate refractory metals such as molybdenum, tantalum, and tungsten. For the Pb-Bi target, three candidate containment materials are suggested based on a literature survey of the materials compatibility and proton irradiation tests: Croloy 2-1/4, modified 9Cr-1Mo, and 12Cr-1Mo (HT-9) steel. These materials seem to be used only if the lead-bismuth is thoroughly deoxidized and treated with zirconium and magnesium

  5. Chemical transport of niobium(V) oxide and of lithium niobate with sulphur

    International Nuclear Information System (INIS)

    Schaefer, H.

    1988-01-01

    Niobium(V) oxide is transported by means of sulphur (calculated for 10 bar at 1223 K) from 1273 → 1173 K. The same applies for lithium niobate. Similar experiments of lithium oxide lead to turbidity of the quartz ampoule. (author)

  6. Lead-free piezoelectric transducers for vibration-based energy harvesting devices

    Energy Technology Data Exchange (ETDEWEB)

    Roescher, Mark

    2011-11-15

    Future applications like piezoelectric energy harvesters in addition with increasing environmental awareness ultimately demand novel sophisticated material systems in the field of piezoelectrics as an alternative to the long-established system lead-zirconate-titanate. In this publication state-of-the-art microgenerators have been designed to possess nonlinear Duffing oscillator characteristics. It is shown by measurement and simulation that lead-zirconate-titanate may hence no longer be the first choice in material selection for a piezoelectric microgenerator. Polyvinylidene fluoride has been integrated in a piezoelectric microgenerator and identified as an extraordinarily promising material system for transducer applications being highly insusceptible to stretching induced material failure. Finally, a fundamentally new chemical synthesis approach has been developed for the fabrication of potassium-sodium-niobate films that may also be suitable for other complex oxides.

  7. Lead line in rodents: an old sign of lead intoxication turned into a new method for environmental surveillance.

    Science.gov (United States)

    de Figueiredo, Fellipe Augusto Tocchini; Ramos, Junia; Kawakita, Erika R Hashimoto; Bilal, Alina S; de Sousa, Frederico B; Swaim, William D; Issa, Joao P Mardegan; Gerlach, Raquel F

    2016-11-01

    The "lead line" was described by Henry Burton in 1840. Rodents are used as sentinels to monitor environmental pollution, but their teeth have not been used to determine lead. To determine whether lead deposits can be observed in the teeth of lead-exposed animals, since the gingival deposits known as "lead line" would likely have a correlate in the calcified tissue to which the gums are opposed during life. Male Wistar rats were exposed to lead in the drinking water (30 mg/L) since birth until 60 days-old. Molars and the incisors of each hemimandible were analyzed by scanning electron microscopy (SEM) on regular and backscattered electrons (BSE) mode. Elements were determined using electron dispersive spectroscopy (EDS). Clean cervical margins were observed on control teeth, as opposed to the findings of extensive deposits on lead-exposed animals, even in hemimandibles that had been exhumed after being buried for 90 days. BSE/EDS indicated that those deposits were an exogenous material compatible with lead sulfite. Presence of calcium, phosphorus, magnesium, carbon, lead, and oxygen is presented. Lead-exposed animals presented marked root resorption. The lead deposits characterized here for the first time show that the "lead line" seen in gums has a calcified tissue counterpart, that is detectable post-mortem even in animals exposed to a low dose of lead. This is likely a good method to detect undue lead exposure and will likely have wide application for pollution surveillance using sentinels.

  8. Processing, properties, and application of textured 0.72lead(magnesium niobate)-0.28lead titanate ceramics

    Science.gov (United States)

    Brosnan, Kristen H.

    In this study, XRD and electron backscatter diffraction (EBSD) techniques were used to characterize the fiber texture in oriented PMN-28PT and the intensity data were fit with a texture model (the March-Dollase equation) that describes the texture in terms of texture fraction (f), and the width of the orientation distribution (r). EBSD analysis confirmed the orientation of the microstructure, with no distinguishable randomly oriented, fine grain matrix. Although XRD rocking curve and EBSD data analysis gave similar f and r values, XRD rocking curve analysis was the most efficient and gave a complete description of texture fraction and texture orientation (f = 0.81 and r = 0.21, respectively). XRD rocking curve analysis was the preferred approach for characterization of the texture volume and the orientation distribution of texture in fiber-oriented PMN-PT. The dielectric, piezoelectric and electromechanical properties for random ceramic, 69 vol% textured, 81 vol% textured, and single crystal PMN-28PT were fully characterized and compared. The room temperature dielectric constant at 1 kHz for highly textured PMN-28PT was epsilonr ≥ 3600 with low dielectric loss (tan delta = 0.004). The temperature dependence of the dielectric constant for 81 vol% textured ceramic followed a similar trend as the single crystal PMN-28PT up to the rhombohedral to tetragonal transition temperature (TRT) at 104°C. 81 vol% textured PMN-28PT consistently displayed 60 to 65% of the single crystal PMN-28PT piezoelectric coefficient (d33) and 1.5 to 3.0 times greater than the random ceramic d33 (measured by Berlincourt meter, unipolar strain-field curves, IEEE standard resonance method, and laser vibrometry). The 81 vol% textured PMN-28PT displayed similarly low piezoelectric hysteresis as single crystal PMN-28PT measured by strain-field curves at 5 kV/cm. 81 vol% textured PMN-28PT and single crystal PMN-28PT displayed similar mechanical quality factors of QM = 74 and 76, respectively. The electromechanical coupling (k 33) of 81 vol% textured PMN-28PT (k33 = 0.79) was a significant fraction of single crystal (k33 = 0.91) and was higher than a commercial PMN-PT ceramic (k33 ˜ 0.74). The nonlinearity of the dielectric and piezoelectric response were investigated in textured ceramics and single crystal PMN-28PT using the Rayleigh approach. The reversible piezoelectric coefficient was found to increase significantly and the hysteretic contribution to the piezoelectric coefficient decreased significantly with an increase in texture volume. This indicates that increasing the texture volume decreases the non-180° domain wall contribution to the piezoelectric response in PMN-28PT. Finally, 81 vol% textured ceramics were also integrated into a Navy SONAR transducer design. In-water characterization of the transducers showed higher source levels, higher in-water coupling, higher acoustic intensity, and more bandwidth for the 81 vol% textured PMN-28PT tonpilz single elements compared to the ceramic PMN-28PT tonpilz element. In addition, an 81 vol% textured PMN-28PT tonpilz element showed large scale linearity in sound pressure levels as a function of drive level under high drive conditions (up to 2.33 kV/cm). The maximum electromechanical coupling obtained by the 81 vol% textured PMN-28PT transducer under high drive conditions was keff = 0.69. However, the resonance frequency shifted significantly during high drive tests (Deltafs = -19% at 3.7 kV/cm), evidence of a "soft" characteristic of the 81 vol% textured PMN-28PT, possibly caused by Sr2+ from the template particles. The results suggest there are limitations on the preload compressive stress (and thus drive level) for these textured ceramics, but this could be addressed with compositional modifications. The dielectric, piezoelectric and electromechanical properties have been significantly improved in textured PMN-PT ceramics of this study. Furthermore, scale-up in processing for incorporation into devices of highly textured ceramics with reproducible texture (and hence narrow properties distribution) was achieved in these materials. SONAR applications could benefit from textured ceramic parts because of their ease of processing, compositional homogeneity and potentially lower cost. (Abstract shortened by UMI.)

  9. Possible Lead Free Nanocomposite Dielectrics for High Energy Storage Applications

    Directory of Open Access Journals (Sweden)

    Srinivas Kurpati

    2017-03-01

    Full Text Available There is an increasing demand to improve the energy density of dielectric capacitors for satisfying the next generation material systems. One effective approach is to embed high dielectric constant inclusions such as lead zirconia titanate in polymer matrix. However, with the increasing concerns on environmental safety and biocompatibility, the need to expel lead (Pb from modern electronics has been receiving more attention. Using high aspect ratio dielectric inclusions such as nanowires could lead to further enhancement of energy density. Therefore, the present brief review work focuses on the feasibility of development of a lead-free nanowire reinforced polymer matrix capacitor for energy storage application. It is expected that Lead-free sodium Niobate nanowires (NaNbO3 and Boron nitride will be a future candidate to be synthesized using simple hydrothermal method, followed by mixing them with polyvinylidene fluoride (PVDF/ divinyl tetramethyl disiloxanebis (benzocyclobutene matrix using a solution-casting method for Nanocomposites fabrication. The energy density of NaNbO3 and BN based composites are also be compared with that of lead-containing (PbTiO3/PVDF Nano composites to show the feasibility of replacing lead-containing materials from high-energy density dielectric capacitors. Further, this paper explores the feasibility of these materials for space applications because of high energy storage capacity, more flexibility and high operating temperatures. This paper is very much useful researchers who would like to work on polymer nanocomposites for high energy storage applications.

  10. Trace elements studies on Karachi population part IV: blood copper, zinc, magnesium and lead levels in psychiatric patients with depression, mental retardation and seizure disorder

    International Nuclear Information System (INIS)

    Manser, W.T.

    1989-01-01

    Blood copper, zinc, magnesium and lead levels were determined by atomic absorption spectroscopy for 15 males and 16 female suffering from depression, 6 males and 1 female with mental retardation and 3 males and 4 females with seizure disorders. They were all under no medication and belong to low income groups. No difference in copper levels was found between the sexes in any of the groups. The levels in all the groups were significantly higher than in the normals. In depressives, males had significantly higher zinc levels than females and only female depressives had lower levels from normals. In both depressives and normals, males had higher magnesium levels than females but no group of patients had significantly different levels from normals. Lead levels were significantly higher in female depressives and for those with seizure disorders than for controls. At least one metal abnormality was found in 21 (67.7%) depressive, 5 (71.4%) of those with mental retardation and 6 (85.7%) with seizure disorders. (author)

  11. Lead-Free Antiferroelectric Silver Niobate Tantalate with High Energy Storage Performance.

    Science.gov (United States)

    Zhao, Lei; Liu, Qing; Gao, Jing; Zhang, Shujun; Li, Jing-Feng

    2017-08-01

    Antiferroelectric materials that display double ferroelectric hysteresis loops are receiving increasing attention for their superior energy storage density compared to their ferroelectric counterparts. Despite the good properties obtained in antiferroelectric La-doped Pb(Zr,Ti)O 3 -based ceramics, lead-free alternatives are highly desired due to the environmental concerns, and AgNbO 3 has been highlighted as a ferrielectric/antiferroelectric perovskite for energy storage applications. Enhanced energy storage performance, with recoverable energy density of 4.2 J cm -3 and high thermal stability of the energy storage density (with minimal variation of ≤±5%) over 20-120 °C, can be achieved in Ta-modified AgNbO 3 ceramics. It is revealed that the incorporation of Ta to the Nb site can enhance the antiferroelectricity because of the reduced polarizability of B-site cations, which is confirmed by the polarization hysteresis, dielectric tunability, and selected-area electron diffraction measurements. Additionally, Ta addition in AgNbO 3 leads to decreased grain size and increased bulk density, increasing the dielectric breakdown strength, up to 240 kV cm -1 versus 175 kV cm -1 for the pure counterpart, together with the enhanced antiferroelectricity, accounting for the high energy storage density. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  13. Textured and tungsten-bronze-niobate-doped (K,Na,Li)(Nb,Ta)O3 piezoceramic materials

    International Nuclear Information System (INIS)

    Soller, Thomas; Bathelt, Robert; Benkert, Katrin; Bodinger, Hermann; Schuh, Carsten; Schlenkrich, Falko

    2010-01-01

    In this study, the effects of an alkaline-earth niobate doping in tungsten-bronze (TB) stoichiometry on the piezoelectric properties and the phase transition temperatures of lead-free (K,Na,Li)(Nb,Ta)O 3 ceramics were investigated. In particular, the TB compounds barium niobate (BN), barium sodium niobate (BNN) and strontium calcium sodium niobate (SCNN) were investigated. The TB-modified ceramics show promising piezoelectric properties with large-signal piezo coefficients, d 33 * lose to 400 pm/V, planar coupling coefficients, k p , up to 0.45 and Curie temperatures of approximately 310 .deg. C. In addition, the effect of texturing on the undoped (K,Na,Li)(Nb,Ta)O 3 base composition via templated grain growth (TGG) with microcrystalline NaNbO 3 templates was examined. Lotgering factors up to 81% and strain enhancements by a factor 1.5 with large-signal values of d 33 * up to 550 pm/V could be achieved in the textured samples.

  14. Lead-free piezoelectrics based on potassium-sodium niobate with giant d(33).

    Science.gov (United States)

    Zhang, Binyu; Wu, Jiagang; Cheng, Xiaojing; Wang, Xiaopeng; Xiao, Dingquan; Zhu, Jianguo; Wang, Xiangjian; Lou, Xiaojie

    2013-08-28

    High-performance lead-free piezoelectrics (d33 > 400 pC/N) based on 0.96(K0.5Na0.5)0.95Li0.05Nb1-xSbxO3-0.04BaZrO3 with the rhombohedral-tetragonal (R-T) phase boundary have been designed and prepared. The R-T phase boundary lies the composition range of 0.04 ≤ x ≤ 0.07, and the dielectric and piezoelectric properties of the ceramics with the compositions near the phase boundary are significantly enhanced. In addition, the ceramic with x = 0.07 has a giant d33 of ~425 pC/N, which is comparable to that (~416 pC/N) of textured KNN-based ceramics (Saito, Y.; Takao, H.; Tani, T.; Nonoyama, T.; Takatori, K.; Homma, T.; Nagaya, T.; Nakamura, M. Nature 2004, 432, 84). The underlying physical mechanisms for enhanced piezoelectric properties are addressed. We believe that the material system is the most promising lead-free piezoelectric candidates for the practical applications.

  15. Towards bio monitoring of toxic (lead) and essential elements in ...

    African Journals Online (AJOL)

    Towards bio monitoring of toxic (lead) and essential elements in whole blood from ... Objectives: Minerals such as zinc, copper, selenium, calcium, and magnesium are essential for normal human development ... One study on the interaction of.

  16. Calcium and magnesium content in hard tissues of rats under condition of subchronic lead intoxication.

    Science.gov (United States)

    Todorovic, Tatjana; Vujanovic, Dragana; Dozic, Ivan; Petkovic-Curcin, Aleksandra

    2008-03-01

    Lead manifests toxic effects in almost all organs and tissues, especially in: the nervous system, hematopoietic system, kidney and liver. This metal has a special affinity for deposition in hard tissue, i.e., bones and teeth. It is generally believed that the main mechanism of its toxicity relies on its interaction with bioelements, especially with Ca and Mg. This article analyses the influence of Pb poisoning on Ca and Mg content in hard tissues, (mandible, femur, teeth and skull) of female and young rats. Experiments were carried out on 60 female rats, AO breed, and on 80 of their young rats (offspring). Female rats were divided into three groups: the first one was a control group, the second one received 100 mg/kg Pb2+ kg b.wt. per day in drinking water, the third one received 30 mg/kg Pb(2+) kg b.wt. per day in drinking water. Young rats (offspring) were divided into the same respective three groups. Lead, calcium and magnesium content in hard tissues (mandible, femur, teeth-incisors and skull) was determined by flame atomic absorption spectrophotometry in mineralized samples. There was a statistically significant Pb deposition in all analyzed female and young rat hard tissues. Ca and Mg contents were significantly reduced in all female and young rat hard tissues. These results show that Pb poisoning causes a significant reduction in Ca and Mg content in animal hard tissues, which is probably the consequence of competitive antagonism between Pb and Ca and Mg.

  17. Blood lead level and its relationship to essential elements in preschool children from Nanning, China.

    Science.gov (United States)

    Chen, Jingwen; Li, Muyan; Lv, Qun; Chen, Guoli; Li, Yong; Li, Shaojun; Mo, Yuhuan; Ou, Shiyan; Yuan, Zongxiang; Huang, Mingli; Jiang, Yueming

    2015-04-01

    Our study aimed to assess the distribution of blood lead level and its relationship to essential elements in preschool children in an urban area of China. A total of 6741 children aged 0- to 6-year-old were recruited. Levels of lead, zinc, copper, iron, calcium, and magnesium in whole blood samples were determined using atomic absorption spectrometry. The mean blood lead level (BLL) and the prevalence of BLL≥10μg/dl (5.26±4.08μg/dl and 6.84%, respectively) increased with age gradually, and there was a gender-difference for blood lead, copper, zinc and iron levels. Compared with the group of children who had BLLslead with zinc, iron and magnesium, and a negative correlation of lead with calcium were found in the group of children with BLLintoxication prevalence in preschool children. Metabolic disorder of essential elements was found even with a low level of lead exposure. Copyright © 2014 Elsevier GmbH. All rights reserved.

  18. High Frequency Magneto Dielectric Effects In Self Assembled Ferrite Ferroelectric Core Shell Nanoparticles

    Science.gov (United States)

    2014-09-10

    ferrimagnetic metals, alloys or oxides and ferroelectrics such as barium titanate (BTO), lead zirconate titanate ( PZT ), and lead magnesium niobate-lead...estimate the magneto-capacitance effect in BTO or PZT films on substrates of ferromagnetic alloys.25 This work is on the observation and theory of MDE...transmission and reflection coefficients were done to estimate the complex permittivity. During the measurements a bias static magnetic field was

  19. Silver Niobate Lead-Free Antiferroelectric Ceramics: Enhancing Energy Storage Density by B-Site Doping.

    Science.gov (United States)

    Zhao, Lei; Gao, Jing; Liu, Qing; Zhang, Shujun; Li, Jing-Feng

    2018-01-10

    Lead-free dielectric ceramics with high recoverable energy density are highly desired to sustainably meet the future energy demand. AgNbO 3 -based lead-free antiferroelectric ceramics with double ferroelectric hysteresis loops have been proved to be potential candidates for energy storage applications. Enhanced energy storage performance with recoverable energy density of 3.3 J/cm 3 and high thermal stability with minimal energy density variation (<10%) over a temperature range of 20-120 °C have been achieved in W-modified AgNbO 3 ceramics. It is revealed that the W 6+ cations substitute the B-site Nb 5+ and reduce the polarizability of B-site cations, leading to the enhanced antiferroelectricity, which is confirmed by the polarization hysteresis and dielectric tunability. It is believed that the polarizability of B-site cations plays a dominant role in stabilizing the antiferroelectricity in AgNbO 3 system, in addition to the tolerance factor, which opens up a new design approach to achieve stable antiferroelectric materials.

  20. Influence of minerals on lead-induced alterations in liver function in rats exposed to long-term lead exposure

    International Nuclear Information System (INIS)

    Herman, D'souza Sunil; Geraldine, Menezes; T, Venkatesh

    2009-01-01

    The objective of this study was to evaluate the role of minerals on lead-induced effect on the liver. Differentiation of minerals and heavy metals pose an inherent problem due to certain common properties shared by them. With this approach to the problem of heavy metal toxicity, in the present study two groups of male Wistar albino rats, one group (well-nourished) fed on mineral rich diet and other group (undernourished) fed on diet without mineral supplements were used. Both the groups of rats were subjected to long-term lead exposure. The diet of well-nourished group was supplemented with calcium (Ca); 1.2%, phosphorous (P); 0.6%, iron (Fe); 90 mg/kg, zinc (Zn); 50 mg/kg, magnesium (Mg); 0.08%, manganese (Mn); 70 mg/kg, selenium (Se); 0.2 mg/kg, copper (Cu); 5 mg/kg, molybdenum (Mo); 0.8 mg/kg, iodine (I); 0.6 mg/kg, cobalt (Co); 3.0 mg/kg. Their blood lead and parameters of liver function were monitored periodically. Results of the study showed a very high statistically significant increase (p < 0.001) in the blood lead (PbB) levels and liver function test parameters in the undernourished subjects compared to the well-nourished subjects. Nutritional management of lead poisoning is of importance since essential elements and toxic heavy metals may interact to minimize the absorption of lead.

  1. Influence of minerals on lead-induced alterations in liver function in rats exposed to long-term lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D' souza Sunil, E-mail: hermansdsouza@rediffmail.com [Department of Biotechnology, Manipal Life Sciences Centre, KMC, Manipal University, Manipal (India); Geraldine, Menezes, E-mail: gere1@rediffmail.com [Department of Biochemistry and Biophysics, St. John' s Medical College, Koramangala, Bangalore 560034, Karnataka (India); T, Venkatesh, E-mail: venky_tv@hotmail.com [Department of Biochemistry and Biophysics, St. John' s Medical College, Koramangala, Bangalore 560034, Karnataka (India)

    2009-07-30

    The objective of this study was to evaluate the role of minerals on lead-induced effect on the liver. Differentiation of minerals and heavy metals pose an inherent problem due to certain common properties shared by them. With this approach to the problem of heavy metal toxicity, in the present study two groups of male Wistar albino rats, one group (well-nourished) fed on mineral rich diet and other group (undernourished) fed on diet without mineral supplements were used. Both the groups of rats were subjected to long-term lead exposure. The diet of well-nourished group was supplemented with calcium (Ca); 1.2%, phosphorous (P); 0.6%, iron (Fe); 90 mg/kg, zinc (Zn); 50 mg/kg, magnesium (Mg); 0.08%, manganese (Mn); 70 mg/kg, selenium (Se); 0.2 mg/kg, copper (Cu); 5 mg/kg, molybdenum (Mo); 0.8 mg/kg, iodine (I); 0.6 mg/kg, cobalt (Co); 3.0 mg/kg. Their blood lead and parameters of liver function were monitored periodically. Results of the study showed a very high statistically significant increase (p < 0.001) in the blood lead (PbB) levels and liver function test parameters in the undernourished subjects compared to the well-nourished subjects. Nutritional management of lead poisoning is of importance since essential elements and toxic heavy metals may interact to minimize the absorption of lead.

  2. Phase transition characteristics and associated piezoelectricity of potassium-sodium niobate lead-free ceramics.

    Science.gov (United States)

    Wang, Yuanyu; Hu, Liang; Zhang, Qilong; Yang, Hui

    2015-08-14

    To achieve high piezoelectric activity and a wide sintering temperature range, the ceramic system concerning (1 - x)(K(0.48)Na(0.52))(Nb(0.96)Sb(0.04))O(3)-x[Bi(0.5)(Na(0.7)Ag(0.3))(0.5)](0.90) Zn(0.10)ZrO(3) was designed, and the rhombohedral-tetragonal (R-T) phase boundary can drive a high d(33). Phase transition characteristics as well as their effects on the electrical properties were investigated systematically. The R-T coexistence phase boundary (0.04 ≤ x ≤ 0.05) can be driven via modification with BNAZZ, and has been confirmed by XRD and temperature-dependent dielectric constants as well as Raman analysis, and the ceramics possess enhanced piezoelectric properties (d(33) ∼ 425 pC N(-1) and k(p) ∼ 0.43) and a high unipolar strain (∼0.3%). In addition, a wide sintering temperature range of 1050-1080 °C can warrant a large d(33) of 400-430 pC N(-1), which can benefit practical applications. As a result, the addition of BNAZZ is an effective method to improve the electrical properties (piezoelectricity and strain) and sintering behavior of potassium-sodium niobate ceramics.

  3. In vivo x-ray fluorescence of bone lead in the study of human lead metabolism: Serum lead, whole blood lead, bone lead, and cumulative exposure

    International Nuclear Information System (INIS)

    Cake, K.M.; Chettle, D.R.; Webber, C.E.; Gordon, C.L.

    1995-01-01

    Traditionally, clinical studies of lead's effect on health have relied on blood lead levels to indicate lead exposure. However, this is unsatisfactory because blood lead levels have a half-life of approximately 5 weeks, and thus reflect recent exposure. Over 90% of the lead body burden is in bone, and it is thought to have a long residence time, thus implying that measurements of bone lead reflect cumulative exposure. So, measurements of bone lead are useful in understanding the long-term health effects of lead. Ahlgren reported the first noninvasive measurements of bone lead in humans, where γ-rays from 57 Co were used to excite the K series x-rays of lead. The lead detection system at McMaster University uses a 109 Cd source which is positioned at the center of the detector face (HPGe) and a near backscatter (∼160 degrees) geometry. This arrangement allows great flexibility, since one can sample lead in a range of different bone sites due to a robust normalization technique which eliminates the need to correct for bone geometry, thickness of overlying tissue, and other related factors. The effective radiation dose to an adult during an x-ray fluorescence bone lead measurement is extremely low, being 35 nSv. This paper addresses the issue of how bone, whole blood, and serum lead concentrations can be related in order to understand a person's lead exposure history

  4. Influence of lead on stabilization/solidification by ordinary Portland cement and magnesium phosphate cement.

    Science.gov (United States)

    Wang, Yan-Shuai; Dai, Jian-Guo; Wang, Lei; Tsang, Daniel C W; Poon, Chi Sun

    2018-01-01

    Inorganic binder-based stabilization/solidification (S/S) of Pb-contaminated soil is a commonly used remediation approach. This paper investigates the influences of soluble Pb species on the hydration process of two types of inorganic binders: ordinary Portland cement (OPC) and magnesium potassium phosphate cement (MKPC). The environmental leachability, compressive strength, and setting time of the cement products are assessed as the primary performance indicators. The mechanisms of Pb involved in the hydration process are analyzed through X-ray diffraction (XRD), hydration heat evolution, and thermogravimetric analyses. Results show that the presence of Pb imposes adverse impact on the compressive strength (decreased by 30.4%) and the final setting time (prolonged by 334.7%) of OPC, but it exerts much less influence on those of MKPC. The reduced strength and delayed setting are attributed to the retarded hydration reaction rate of OPC during the induction period. These results suggest that the OPC-based S/S of soluble Pb mainly depends on physical encapsulation by calcium-silicate-hydrate (CSH) gels. In contrast, in case of MKPC-based S/S process, chemical stabilization with residual phosphate (pyromorphite and lead phosphate precipitation) and physical fixation of cementitious struvite-K are the major mechanisms. Therefore, MKPC is a more efficient and chemically stable inorganic binder for the Pb S/S process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. PHYSICAL AND ELECTRICAL PROPERTIES ENHANCEMENT OF RARE-EARTH DOPED-POTASSIUM SODIUM NIOBATE (KNN: A REVIEW

    Directory of Open Access Journals (Sweden)

    Akmal Mat Harttat Maziati

    2015-06-01

    Full Text Available Alkaline niobate mainly potassium sodium niobate, (KxNa1-x NbO3 (abreviated as KNN has long attracted attention as piezoelectric materials as its high Curie temperature (Tc and piezoelectric properties. The volatility of alkaline element (K, Na is, however detrimental to the stoichiometry of KNN, contributing to the failure to achieve high-density structure and lead to the formation of intrinsic defects. By partially doping of several rare-earth elements, the inherent defects could be improved significantly. Therefore, considerable attempts have been made to develop doped-KNN based ceramic materials with high electrical properties. In this paper, these research activities are reviewed, including dopants type and doping role in KNN perovskite structure.

  6. Lithium niobate packaging challenges

    International Nuclear Information System (INIS)

    Murphy, E.J.; Holmes, R.J.; Jander, R.B.; Schelling, A.W.

    1988-01-01

    The use of lithium niobate integrated optic devices outside of the research laboratory is predicated on the development of a sound packaging method. The authors present a discussion of the many issues that face the development of a viable, robust packaging technology. The authors emphasize the interaction of lithium niobate's physical properties with available packaging materials and technologies. The broad range of properties (i.e. electro-optic, piezo-electric, pyro-electric, photorefractive...) that make lithium niobate an interesting material in many device applications also make it a packaging challenge. The package design, materials and packaging technologies must isolate the device from the environment so that lithium niobate's properties do not adversely affect the device performance

  7. Review and Perspectives of Aurivillius Structures as a Lead-Free Piezoelectric System

    Directory of Open Access Journals (Sweden)

    Alberto Moure

    2018-01-01

    Full Text Available According to the EU-Directives 2002/95/EC, 2002/96/EC, lead-based piezoceramics must be substituted in the future with more environmentally friendly alternatives, only when a reliable alternative is found. This is why an increasing interest has grown in the research community to find lead free piezoelectric materials that fulfil the requirements for this substitution. Different families of compounds have been shown to be possible candidates for this use, such as bismuth and niobates based perovskites, pyrochlores, etc. However, a material with piezoelectric coefficients similar to those of PZT (lead zirconate titanate, Pb[ZrxTi1-x]O3 has not been yet found. Besides, each of these families has its specific characteristics in terms of remnant polarization, coercive field or application temperature. Thus, the choice of each material should be made according to the specific needs of the application. In this sense, Aurivillius-type structure materials (also known as Bismuth Layered Structure Ferroelectrics, BLSF can take advantage of their specific properties for uses as Lead Free Piezoelectric systems. Some of them have a high Curie temperature, which make them good candidates to be used as high temperature piezoelectrics; high coercive fields, which facilitates their use as actuators; or a high switching fatigue resistance, which can be useful for future applications as Ferroelectric Random Access Memories (FERAM.

  8. Irradiation-induced modification of the material parameters in magnesium-doped lithium niobate

    International Nuclear Information System (INIS)

    Jentjens, Lena

    2010-01-01

    In the framework of this thesis the material properties of lithium niobate are directedly influenced by the irradiation with 3 He ions with an energy of 40 MeV. In the first part the irradiation-induced material changes are intensively studied. Long-time stable changes of the refractive index are measured in the range of up to 6.10 -3 , which depend on the radiation dose and exhibit until now no saturation behaviour. Accompanied is this change by an also dose-dependent deformation as well as a brownish change of color of the crystals. Furthermore a by several orders of magnitude increased electrical dark- and photoconductivity, which depends on the ion dose and exhibits until now also no saturation behaviour. An effect independent on the ion dose is the reduction of the coercive field strength by about 10%. Furthermore it was stated the quantity of the effects not only depends on the absolute dose, but also on the irradiation direction in view of the crystallographic c-axis. The second part of this thesis deals with the generation of microscopic structures in lithium niobate. By an ion microbeam respectively a shiftable slit aperture the fabrication of refractive-index gratings is pursued. Grating with periodicity lengths in the range of 12-160 μm could until now be detected and promise in comparison with photorefractive gratings the advance of larger stability.

  9. Essential elements, cadmium, and lead in raw and pasteurized cow and goat milk

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, A.; Collins, W.F.; Williams, H.L.

    1985-08-01

    Fifteen essential elements plus cadmium and lead were determined in raw and pasteurized cow and goat milks by atomic absorption spectrophotometry. When results were compared on a wet weight basis, there were no significant differences between the raw and pasteurized milks except for cobalt, iron, and lead in goat milk. When copper in goat milk was expressed on a dry weight basis, there was a significant difference between raw and pasteurized milk. There were significantly higher amounts of cobalt, copper, iron, lead, magnesium, and phosphorus, wet weight basis, in pasteurized goat milk than in pasteurized cow milk. Significantly more nickel and sodium were in pasteurized cow milk. No difference in the content of chloride, calcium, potassium, and zinc was significant between the two milks. When dry weights of the two milks were compared, statistical differences were the same, except there was significantly more calcium and potassium in pasteurized cow milk than in pasteurized goat milk and there were no significant differences in the content of lead and phosphorus between the two milks. Percentages of the established and estimated recommended daily allowances show both cow and goat milk to be excellent sources of calcium, phosphorus, and potassium and fair sources of iron, magnesium, and sodium.

  10. Total contribution of airborne lead to blood lead.

    OpenAIRE

    Manton, W I

    1985-01-01

    A nine year study of blood lead concentrations and isotope ratios carried out on a married couple shows that pulmonary deposition cannot account for all the airborne lead in blood; that lead from bone may comprise 70% of blood lead; and that during pregnancy blood lead may double due to mobilisation of lead from bone.

  11. Total contribution of airborne lead to blood lead.

    Science.gov (United States)

    Manton, W I

    1985-01-01

    A nine year study of blood lead concentrations and isotope ratios carried out on a married couple shows that pulmonary deposition cannot account for all the airborne lead in blood; that lead from bone may comprise 70% of blood lead; and that during pregnancy blood lead may double due to mobilisation of lead from bone. PMID:3970881

  12. Lead- or Lead-bismuth-cooled fast reactors

    International Nuclear Information System (INIS)

    Bouchter, J.C.; Courouau, J.L.; Dufour, P.; Guidez, J.; Latge, C.; Martinelli, L.; Renault, C.; Rimpault, G.

    2014-01-01

    Lead-cooled fast reactors are one of the 6 concepts retained for the 4. generation of nuclear reactors. So far no lead-cooled reactors have existed in the world except lead-bismuth-cooled reactors in soviet submarines. Some problems linked to the use of the lead-bismuth eutectic appeared but were satisfactorily solved by a more rigorous monitoring of the chemistry of the lead-bismuth coolant. Lead presents various advantages as a coolant: no reactivity with water and the air,a high boiling temperature and low contamination when irradiated. The main asset of the lead-bismuth alloy is the drop of the fusion temperature from 327 C degrees to 125 C degrees. The main drawback of using lead (or lead-bismuth) is its high corrosiveness with metals like iron, chromium and nickel. The high corrosiveness of the coolant implies low flow velocities which means a bigger core and consequently a bigger reactor containment. Different research programs in the world (in Europe, Russia and the USA) are reviewed in the article but it appears that the development of this type of reactor requires technological breakthroughs concerning materials and the resistance to corrosion. Furthermore the concept of lead-cooled reactors seems to be associated to a range of low output power because of the compromise between the size of the reactor and its resistance to earthquakes. (A.C.)

  13. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  14. Shape manipulation of ion irradiated Ag nanoparticles embedded in lithium niobate

    International Nuclear Information System (INIS)

    Wolf, Steffen; Rensberg, Jura; Johannes, Andreas; Ronning, Carsten; Thomae, Rainer; Smit, Frederick; Neveling, Retief; Bharuth-Ram, Krish; Moodley, Mathew; Bierschenk, Thomas; Rodriguez, Matias; Afra, Boshra; Ridgway, Mark; Hasan, Shakeeb Bin; Rockstuhl, Carsten

    2016-01-01

    Spherical silver nanoparticles were prepared by means of ion beam synthesis in lithium niobate. The embedded nanoparticles were then irradiated with energetic "8"4Kr and "1"9"7Au ions, resulting in different electronic energy losses between 8.1 and 27.5 keV nm"−"1 in the top layer of the samples. Due to the high electronic energy losses of the irradiating ions, molten ion tracks are formed inside the lithium niobate in which the elongated Ag nanoparticles are formed. This process is strongly dependent on the initial particle size and leads to a broad aspect ratio distribution. Extinction spectra of the samples feature the extinction maximum with shoulders on either side. While the maximum is caused by numerous remaining spherical nanoparticles, the shoulders can be attributed to elongated particles. The latter could be verified by COMSOL simulations. The extinction spectra are thus a superposition of the spectra of all individual particles. (paper)

  15. Effect of the structure and mechanical properties of the near-surface layer of lithium niobate single crystals on the manufacture of integrated optic circuits

    Science.gov (United States)

    Sosunov, A. V.; Ponomarev, R. S.; Yur'ev, V. A.; Volyntsev, A. B.

    2017-01-01

    This paper shows that the near-surface layer of a lithium niobate single layer 15 μm in depth is essentially different from the rest of the volume of the material from the standpoint of composition, structure, and mechanical properties. The pointed out differences are due to the effect of cutting, polishing, and smoothing of the lithium niobate plates, which increase the density of point defects and dislocations. The increasing density of the structural defects leads to uncontrollable changes in the conditions of the formations of waveguides and the drifting of characteristics of integrated optical circuits. The results obtained are very important for the manufacture of lithium niobate based integrated optical circuits.

  16. The optimum lead thickness for lead-activation detectors

    International Nuclear Information System (INIS)

    Si Fenni; Hu Qingyuan

    2009-01-01

    The optimum lead thickness for lead-activation detectors has been studied in this paper. First existence of the optimum lead thickness is explained theoretically. Then the optimum lead thickness is obtained by two methods, MCNP5 calculation and mathematical estimation. At last factors which affect the optimum lead thickness are discussed. It turns out that the optimum lead thickness is irrelevant to incident neutron energies. It is recommended 2.5 cm generally.

  17. Effects of lead accumulation on the Azolla caroliniana-Anabaena association.

    Science.gov (United States)

    Roberts, Anne E; Boylen, Charles W; Nierzwicki-Bauer, Sandra A

    2014-04-01

    The effect of lead accumulation on photopigment production, mineral nutrition, and Anabaena vegetative cell size and heterocyst formation in Azolla caroliniana was investigated. Plants were exposed to 0, 1, 5, 10, and 20 mg L(-1) lead acetate for ten days. Lead accumulation increased when plants were treated with higher lead concentrations. Results revealed a statistically significant decline in total chlorophyll, chlorophyll a, chlorophyll b, and carotenoids in 5, 10, and 20 mg Pb L(-1) treatment groups as compared to plants with 0 or 1 mg Pb L(-1) treatments. No statistically significant change in anthocyanin production was observed. Calcium, magnesium, and zinc concentrations in plants decreased in increasing treatment groups, whereas sodium and potassium concentrations increased. Nitrogen and carbon were also found to decrease in plant tissue. Anabaena vegetative cells decreased in size and heterocyst frequency declined rapidly in a Pb dose-dependent manner. These results indicate that, while A. caroliniana removes lead from aqueous solution, the heavy metal causes physiological and biochemical changes by impairing photosynthesis, changing mineral nutrition, and impeding the growth and formation of heterocysts of the symbiotic cyanobacteria that live within leaf cavities of the fronds. Copyright © 2014. Published by Elsevier Inc.

  18. Dietary magnesium deficiency alters gut microbiota and leads to depressive-like behaviour.

    Science.gov (United States)

    Winther, Gudrun; Pyndt Jørgensen, Betina M; Elfving, Betina; Nielsen, Denis Sandris; Kihl, Pernille; Lund, Sten; Sørensen, Dorte Bratbo; Wegener, Gregers

    2015-06-01

    Gut microbiota (GM) has previously been associated with alterations in rodent behaviour, and since the GM is affected by the diet, the composition of the diet may be an important factor contributing to behavioural changes. Interestingly, a magnesium restricted diet has been shown to induce anxiety and depressive-like behaviour in humans and rodents, and it could be suggested that magnesium deficiency may mediate the effects through an altered GM. The present study therefore fed C57BL/6 mice with a standard diet or a magnesium deficient diet (MgD) for 6 weeks, followed by behavioural testing in the forced swim test (FST) to evaluate depressive-like behaviour. An intraperitoneal glucose tolerance test (GTT) was performed 2 day after the FST to assess metabolic alterations. Neuroinflammatory markers were analysed from hippocampus. GM composition was analysed and correlated to the behaviour and hippocampal markers. It was found that mice exposed to MgD for 6 weeks were more immobile than control mice in the FST, suggesting an increased depressive-like behaviour. No significant difference was detected in the GTT. GM composition correlated positively with the behaviour of undisturbed C57BL/6 mice, feeding MgD diet altered the microbial composition. The altered GM correlated positively to the hippocampal interleukin-6. In conclusion, we hypothesise that imbalances of the microbiota-gut-brain axis induced by consuming a MgD diet, contributes to the development of depressive-like behaviour.

  19. Lead poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Beijers, J A

    1952-01-01

    Three cases of acute lead poisoning of cattle herds via ingestion are reported, and reference is made to several other incidents of lead in both humans and animals. The quantity of lead which was found in the livers of the dead cows varied from 6.5 to 19 mg/kg, while 1160 mg/kg of lead in the liver was found for a young cow which was poisoned experimentally with 5 gms of lead acetate per day; hence, there appears to be great variability in the amounts deposited that can lead to intoxication and death. No evidence was found for a lead seam around the teeth, prophyrinuria, or basophil granules in the erythrocytes during acute or chronic lead poisoning of cattle or horses examined. Reference is made to attempts of finding the boundary line between increased lead absorption and lead intoxication in humans, and an examination of 60 laborers in an offset-printing office containing a great deal of inhalable lead (0.16 to 1.9 mg/cu m air) is reviewed. Physical deviation, basophylic granulation of erythrocytes, increased lead content of the urine, and porphyrinuria only indicate an increased absorption of lead; the use of the term intoxication is justified if, in addition, there are complaints of lack of appetite, constipation, fatigue, abdominal pain, and emaciation.

  20. Biosorption of lead phosphates by lead-tolerant bacteria as a mechanism for lead immobilization.

    Science.gov (United States)

    Rodríguez-Sánchez, Viridiana; Guzmán-Moreno, Jesús; Rodríguez-González, Vicente; Flores-de la Torre, Juan Armando; Ramírez-Santoyo, Rosa María; Vidales-Rodríguez, Luz Elena

    2017-08-01

    The study of metal-tolerant bacteria is important for bioremediation of contaminated environments and development of green technologies for material synthesis due to their potential to transform toxic metal ions into less toxic compounds by mechanisms such as reduction, oxidation and/or sequestration. In this study, we report the isolation of seven lead-tolerant bacteria from a metal-contaminated site at Zacatecas, México. The bacteria were identified as members of the Staphylococcus and Bacillus genera by microscopic, biochemical and 16S rDNA analyses. Minimal inhibitory concentration of these isolates was established between 4.5 and 7.0 mM of Pb(NO 3 ) 2 in solid and 1.0-4.0 mM of Pb(NO 3 ) 2 in liquid media. A quantitative analysis of the lead associated to bacterial biomass in growing cultures, revealed that the percentage of lead associated to biomass was between 1 and 37% in the PbT isolates. A mechanism of complexation/biosorption of lead ions as inorganic phosphates (lead hydroxyapatite and pyromorphite) in bacterial biomass, was determined by Fourier transform infrared spectroscopy and X-ray diffraction analyses. Thus, the ability of the lead-tolerant isolates to transform lead ions into stable and highly insoluble lead minerals make them potentially useful for immobilization of lead in mining waste.

  1. Electronic and Optical Properties of Sodium Niobate: A Density Functional Theory Study

    Directory of Open Access Journals (Sweden)

    Daniel Fritsch

    2018-01-01

    Full Text Available In recent years, much effort has been devoted to replace the most commonly used piezoelectric ceramic lead zirconate titanate Pb[ZrxTi1−x]O3 (PZT with a suitable lead-free alternative for memory or piezoelectric applications. One possible alternative to PZT is sodium niobate as it exhibits electrical and mechanical properties that make it an interesting material for technological applications. The high-temperature simple cubic perovskite structure undergoes a series of structural phase transitions with decreasing temperature. However, particularly the phases at room temperature and below are not yet fully characterised and understood. Here, we perform density functional theory calculations for the possible phases at room temperature and below and report on the structural, electronic, and optical properties of the different phases in comparison to experimental findings.

  2. Phase formation, dielectric and magnetic properties of bismuth ferrite–lead magnesium niobate multiferroic composites

    Energy Technology Data Exchange (ETDEWEB)

    Wongmaneerung, R., E-mail: re_nok@yahoo.com [Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Padchasri, J.; Tipakontitikul, R. [Department of Physics, Ubonratchathani University, Ubonratchathani 31490 (Thailand); Loan, T.H. [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology, No. 1, Dai Co Viet, Hanoi (Viet Nam); Jantaratana, P. [Department of Physics, Kasetsart University, Bangkok 10900 (Thailand); Yimnirun, R. [School of Physics, Institute of Science, and NANOTEC-SUT Center of Excellence of Advanced Functional Nanomaterials, Suranaree University of Technology, Nakhon Ratchasima 30000 (Thailand); Ananta, S. [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2014-09-01

    Highlights: • A bimodal particle size concept was designed in the production of BF–PMN composites. • A very abnormal diffuse dielectric pattern is observed during the heating process. • BF–PMN composites show highly saturated magnetization. - Abstract: Binary multiferroic composites (1−x)BiFeO{sub 3}–xPb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3} (BF–PMN; x = 0.0–50 wt%) were fabricated through a traditional ceramic process. The effect of the PMN contents on the phase assemblage, microstructure, dielectric and magnetic properties of the samples were investigated by X-ray diffraction (XRD), scanning electron microscope (SEM), LCR meter and vibrating sample magnetometer (VSM), respectively. The results indicate that all composites show that perovskite structure and PMN phase is compatible with the BF phase. The microstructure displays the mix phases between BF, PMN, Bi-rich BF and Fe-rich BF phases. Dielectric anomalies of these composites are totally different from BiFeO{sub 3} single phase. Moreover, the dielectric constant is found to increase as the content of PMN decreases. Magnetic transition temperatures are in the range of 270–440 °C. Interestingly, the M–H hysteresis loop measurements indicated that all composites exhibited weak ferromagnetism behavior at room temperature. The maximum remanent magnetization M{sub r} is observed for x = 30 wt% and then decreases when the PMN content is more than 40 wt%.

  3. Interaction of copper, magnesium, zinc, cadmium and lead formiates

    International Nuclear Information System (INIS)

    Gyunner, Eh.A.; Mel'nichenko, L.M.; Yakhkind, N.D.; Vel'mozhnyj, I.S.; Katseva, G.N.

    1979-01-01

    Measurements of the residual concentrations of the interacting ions and refraction index of liquid phases were useful in determining the precipitate composition in the system MA 2 -NaOH-H 2 O(A - -HCOO - ; M 2+ -Cu 2+ , Mg 2+ , Zn 2+ , Cd 2+ , Pb 2+ ). It is shown that in the system CdA 2 -NaOH-H 2 O containing as high as 40 mole% of NaOH the precipitate composition is approximately constant and corresponds to hydroxoformiate Cd(OH)A which is formed by the equation Cd 2+ +OH - +A - =Cd(OH)A. Further increase in the NaOH content leads to the formation of varying-composition precipitates and, at a NaOH content >=66.6 mole%, - to cadmium hydroxide

  4. Lead and lead-based alloys as waste matrix materials

    International Nuclear Information System (INIS)

    Arustamov, A.E.; Ojovan, M.I.; Kachalov, M.B.

    1999-01-01

    Metals and alloys with relatively low melting temperatures such as lead and lead-based alloys are considered in Russia as prospective matrices for encapsulation of spent nuclear fuel in containers in preparation for final disposal in underground repositories. Now lead and lead-based alloys are being used for conditioning spent sealed radioactive sources at radioactive waste disposal facilities

  5. Lead poisoning

    Science.gov (United States)

    ... drinking water in homes containing pipes that were connected with lead solder . Although new building codes require ... lead in their bodies when they put lead objects in their mouths, especially if they swallow those ...

  6. Lead Poisoning

    Science.gov (United States)

    Lead is a metal that occurs naturally in the earth's crust. Lead can be found in all parts of our ... from human activities such as mining and manufacturing. Lead used to be in paint; older houses may ...

  7. Magnesium alleviates adverse effects of lead on growth, photosynthesis and ultrastructural alterations of Torreya grandis seedlings

    Directory of Open Access Journals (Sweden)

    Jie Shen

    2016-11-01

    Full Text Available Magnesium (Mg2+ has been shown to reduce the physiological and biochemical stress in plants caused by heavy metals. To date our understanding of how Mg2+ ameliorates the adverse effects of heavy metals in plants is scarce. The potential effect of Mg2+ on lead (Pb2+ toxicity in plants has not yet been studied. This study was designed to clarify the mechanism of Mg2+-induced alleviation of lead (Pb2+ toxicity. Torreya grandis (T. grandis seedlings were grown in substrate contaminated with 0, 700 and 1400 mg Pb2+ per kg-1 and with or without the addition of 1040 mg kg-1 Mg2+. Growth parameters, concentrations of Pb2+ and Mg2+ in the plants’ shoots and roots, photosynthetic pigment, gas exchange parameters, the maximum quantum efficiency (Fv/Fm, root oxidative activity, ultrastructure of chloroplasts and root growth were determined to analyze the effect of different Pb2+ concentrations in the seedlings as well as the potential ameliorating effect of Mg2+ on the Pb2+ induced toxicity. The growth of T. grandis seedlings cultivated in soils treated with 1400 mg kg-1 Pb2+ was significantly reduced compared with that of plants cultivated in soils treated with 0 or 700 mg kg-1 Pb2+. The addition of 1040 mg kg-1 Mg2+ improved the growth of the Pb2+-stressed seedlings, which was accompanied by increased chlorophyll content, the net photosynthetic rate and Fv/Fm, and enhanced chloroplasts development. In addition, the application of Mg2+ induced plants to accumulate five times higher concentrations of Pb2+ in the roots and to absorb and translocate four times higher concentrations of Mg2+ to the shoots than those without Mg2+ application. Furthermore, Mg2+ addition increased root growth and oxidative activity, and protected the root ultrastructure. To the best of our knowledge, our study is the first report on the mechanism of Mg2+-induced alleviation of Pb2+ toxicity. The gener¬ated results may have important implications for understanding the

  8. Magnesium-DNA interactions and the possible relation of magnesium to carcinogenesis. Irradiation and free radicals.

    Science.gov (United States)

    Anastassopoulou, J; Theophanides, T

    2002-04-01

    Magnesium deficiency causes renal complications. The appearance of several diseases is related to its depletion in the human body. In radiotherapy, as well as in chemotherapy, especially in treatment of cancers with cis-platinum, hypomagnesaemia is observed. The site effects of chemotherapy that are due to hypomagnesaemia are decreased using Mg supplements. The role of magnesium in DNA stabilization is concentration dependent. At high concentrations there is an accumulation of Mg binding, which induces conformational changes leading to Z-DNA, while at low concentration there is deficiency and destabilization of DNA. The biological and clinical consequences of abnormal concentrations are DNA cleavage leading to diseases and cancer. Carcinogenesis and cell growth are also magnesium-ion concentration dependent. Several reports point out that the interaction of magnesium in the presence of other metal ions showed that there is synergism with Li and Mn, but there is magnesium antagonism in DNA binding with the essential metal ions in the order: Zn>Mg>Ca. In the case of toxic metals such as Cd, Ga and Ni there is also antagonism for DNA binding. It was found from radiolysis of deaerated aqueous solutions of the nucleoside 5'-guanosine monophosphate (5'-GMP) in the presence as well as in the absence of magnesium ions that, although the addition of hydroxyl radicals (*OH) has been increased by 2-fold, the opening of the imidazole ring of the guanine base was prevented. This effect was due to the binding of Mg2+ ions to N7 site of the molecule by stabilizing the five-member ring imitating cis-platinum. It was also observed using Fourier Transform Infrared spectroscopy, Raman spectroscopy and Fast Atom Bombardment mass spectrometry that *OH radicals subtract H atoms from the C1', C4' and C5' sites of the nucleotide. Irradiation of 5'-GMP in the presence of oxygen (2.5 x 10(-4) M) shows that magnesium is released from the complex. There is spectroscopic evidence that

  9. Lead Test

    Science.gov (United States)

    ... to do renovation and repair projects using lead-safe work practices to avoid creating more lead dust or ... in a dangerous area? Yes. If you are working in a potentially harmful environment with exposure to lead dust or fumes: Wash ...

  10. Annealed proton exchanged optical waveguides in lithium niobate differences between the X- and Z-cuts

    CERN Document Server

    Nekvindova, P; Cervena, J; Budnar, M; Razpet, A; Zorko, B; Pelicon, P; 10.1016/S0925-3467(01)00186-0

    2002-01-01

    Summarizes results and assessments of our systematic fabrication and characterization of proton exchanged (PE) and annealed proton exchanged (APE) waveguides in lithium niobate. This study focused on different behavior of crystallographically diverse X(1120) and Z (0001) substrate cuts during waveguide fabrication, and differences in characteristics of the resulting waveguides. Non-toxic adipic acid was used as a proton source, and the waveguides properties were defined by mode spectroscopy (waveguide characteristics) and neutron depth profiling (NDP, lithium concentration and distribution), infrared vibration spectra and elastic recoil detection analysis (ERDA, concentration and depth distribution of hydrogen). It was discovered that the X-cut structure is more permeable for moving particles (lithium and hydrogen ions), which leads to a higher effectiveness of the PE process within the X-cut. The explanation of this phenomenon is based on fitting X-cut orientation towards cleavage planes of lithium niobate c...

  11. Bulk diffusion and solubility of silver and nickel in lead, lead-silver and lead-nickel solid solutions

    International Nuclear Information System (INIS)

    Amenzou-Badrour, H.; Moya, G.; Bernardini, J.

    1988-01-01

    The results of a study of solubility and bulk diffusion of /sup 110/Ag and /sup 63/Ni in lead, lead-silver and lead-nickel solid solutions in the temperature range 220 to 88 0 C are reported. Owing to the low solubility of silver and nickel in lead, Fick's solution corresponding to the boundary condition of a constant concentration of solute at the surface has been used. Depth profile concentration analysis suggests a fundamental difference between the diffusion mechanisms of silver and nickel. Since silver penetration profiles in pure lead give diffusion coefficients independent of the penetration depth and silver concentration, it is suggested that slight decreases of silver diffusivity in lead-silver solid solutions have no significance. This implies that the interstitial silver atoms do not associate significantly with each other to form Ag-Ag dimers. In contrast, different behaviors of /sup 63/Ni depth profile concentration in pure lead and saturated PbNi solid solutions agree with a Ni-Ni interaction leading to the formation of less mobile dimers near the surface in pure lead

  12. Electrical properties of a novel lead alkoxide precursor: Lead glycolate

    International Nuclear Information System (INIS)

    Tangboriboon, Nuchnapa; Pakdeewanishsukho, Kittikhun; Jamieson, Alexander; Sirivat, Anuvat; Wongkasemjit, Sujitra

    2006-01-01

    The reaction of lead acetate trihydrate Pb(CH 3 COO) 2 .3H 2 O and ethylene glycol, using triethylenetetramine (TETA) as a catalyst, provides in one step access to a polymer-like precursor of lead glycolate [-PbOCH 2 CH 2 O-]. On the basis of high-resolution mass spectroscopy, chemical analysis composition, FTIR, 13 C-solid state NMR and TGA, the lead glycolate precursor can be identified as a trimer structure. The FTIR spectrum demonstrates the characteristics of lead glycolate; the peaks at 1086 and 1042 cm -1 can be assigned to the C-O-Pb stretchings. The 13 C-solid state NMR spectrum gives notably only one peak at 68.639 ppm belonging to the ethylene glycol ligand. The phase transformations of lead glycolate and lead acetate trihydrate to lead oxide, their microstructures, and electrical properties were found to vary with increasing temperature. The lead glycolate precursor has superior electrical properties relative to those of lead acetate trihydrate, suggesting that the lead glycolate precursor can possibly be used as a starting material for producing electrical and semiconducting ceramics, viz. ferroelectric, anti-ferroelectric, and piezoelectric materials

  13. Relational Leading

    DEFF Research Database (Denmark)

    Larsen, Mette Vinther; Rasmussen, Jørgen Gulddahl

    2015-01-01

    This first chapter presents the exploratory and curious approach to leading as relational processes – an approach that pervades the entire book. We explore leading from a perspective that emphasises the unpredictable challenges and triviality of everyday life, which we consider an interesting......, relevant and realistic way to examine leading. The chapter brings up a number of concepts and contexts as formulated by researchers within the field, and in this way seeks to construct a first understanding of relational leading....

  14. Correlation between some parameters of lead absorption and lead intoxication

    Science.gov (United States)

    Waldron, H. A.

    1971-01-01

    Waldron, H. A. (1971).Brit. J. industr. Med.,28, 195-199. Correlation between some parameters of lead absorption and lead intoxication. Use has been made of data collected over a number of years from workers exposed to a lead hazard in a motor-car factory. The correlations between various parameters of lead absorption and lead intoxication were computed, including blood and urine lead concentrations, urinary coproporphyrin, ALA and PBG concentrations, and haemoglobin concentration. In all, 15 correlation coefficients were calculated, of which only six showed a statistically significant result (i.e., Plead and urine lead (r = 0·38, Plead and coproporphyrin (r = 0·42, Plead and ALA (r = 0·43, Plead and PBG (r = 0·19, P<0·05). PMID:5572689

  15. Lead and silver extraction from waste cake from hydrometallurgical zinc production

    Directory of Open Access Journals (Sweden)

    DUSAN D. STANOJEVIC

    2008-05-01

    Full Text Available This paper presents the experimental results of the extraction of lead and silver from a lead–silver waste cake obtained in the process of hydrometallurgical zinc production. While controlling the pH value, the lead–silver cake was leached at a temperature close to boiling point in different concentrations of aqueous calcium chloride solutions. The experiments were performed applying different ratios between the mass of cake and the volume of the leaching agent under different durations of the process. It was concluded that at the optimal process parameters (pH 2.0–2.5; CaCl2 concentration, 3.6 mol dm-3; temperature, 95 °C; solid/liquid ratio, 1:5, the leaching efficiency of lead and silver could reach the approximate value of 94 %. Applying the same optimal process parameters, the method was applied to the leaching of a lead–silver cake in a magnesium chloride solution, but with significantly lower efficiencies. The results show that leaching of lead and silver in a calcium chloride solution could be a prospective method for increasing the recovery of lead and silver during hydrometallurgical zinc production.

  16. Effect of Magnesium Hydride on the Corrosion Behavior of Pure Magnesium in 0.1 M NaCl Solution

    OpenAIRE

    Xu, Shanna; Dong, Junhua; Ke, Wei

    2010-01-01

    The effect of magnesium hydride on the corrosion behavior of pure magnesium in 0.1 M NaCl solution was investigated using the gas collection method, potentiostatic current decay test, and in situ Raman spectrum. The formation of magnesium hydride (MgH2, Mg2H4) was observed at the cathodic region. Applying anodic potential leads to decomposition of magnesium hydride. Magnesium hydride plays an important role on the negative difference effect (NDE) in both the cathodic and anodic regions.

  17. The identification of lead ammunition as a source of lead exposure in First Nations: The use of lead isotope ratios

    International Nuclear Information System (INIS)

    Tsuji, Leonard J.S.; Wainman, Bruce C.; Martin, Ian D.; Sutherland, Celine; Weber, Jean-Philippe; Dumas, Pierre; Nieboer, Evert

    2008-01-01

    The use of lead shotshell to hunt water birds has been associated with lead-contamination in game meat. However, evidence illustrating that lead shotshell is a source of lead exposure in subsistence hunting groups cannot be deemed definitive. This study seeks to determine whether lead shotshell constitutes a source of lead exposure using lead isotope ratios. We examined stable lead isotope ratios for lichens, lead shotshell and bullets, and blood from residents of Fort Albany and Kashechewan First Nations, and the City of Hamilton, Ontario, Canada. Data were analyzed using ANOVA and regression analyses. ANOVA of isotope ratios for blood revealed significant differences with respect to location, but not sex. Hamilton differed from both Kashechewan and Fort Albany; however, the First Nations did not differ from each other. ANOVA of the isotope ratios for lead ammunition and lichens revealed no significant differences between lichen groups (north and south) and for the lead ammunition sources (pellets and bullets). A plot of 206 Pb/ 204 Pb and 206 Pb/ 207 Pb values illustrated that lichens and lead ammunition were distinct groupings and only the 95% confidence ellipse of the First Nations group overlapped that of lead ammunition. In addition, partial correlations between blood-lead levels (adjusted for age) and isotope ratios revealed significant (p 206 Pb/ 204 Pb and 206 Pb/ 207 Pb, and a significant negative correlation for 208 Pb/ 206 Pb, as predicted if leaded ammunition were the source of lead exposure. In conclusion, lead ammunition was identified as a source of lead exposure for First Nations people; however, the isotope ratios for lead shotshell pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden

  18. Effect on blood lead of airborne lead particles characterized by size.

    Science.gov (United States)

    Park, Dong-Uk; Paik, Nam-Won

    2002-03-01

    Worker exposure to airborne lead particles was evaluated for a total of 117 workers in 12 work-places of four different industrial types in Korea. The particle sizes were measured using 8-stage cascade impactors worn by the workers. Mass median aerodynamic diameters (MMAD) were determined by type of industry and percentage of lead particles as a fraction of airborne lead (PbA) concentration was determined by particle size. Blood lead (PbB) levels of workers who matched airborne lead samples were also examined. A Scheffé's pairwise comparison test showed that MMAD and the fractions of each of respirable particles and lead particles lead particles lead particles (r = 0.82) than that between concentrations of small particles and PbA (r = 0.61). A simple linear regression indicated that PbB correlated better with respirable lead concentration (r2 = 0.35, P = 0.0001) than with PbA concentration and had a higher slope coefficient. Controlling for respirable lead concentration reduced the partial correlation coefficient between PbA concentration and PbB level from 0.56 to 0.20 (P = 0.053). The results indicate that the contribution of respirable lead particles to lead absorption would be greater than that of PbA. This study concludes that the measurement of PbA only may not properly reflect a worker's exposure to lead particles with diverse characteristics. For the evaluation of a worker's exposure to various types of lead particles, it is recommended that respirable lead particles as well as PbA be measured.

  19. Chemical stabilisation of lead in shooting range soils with phosphate and magnesium oxide: Synchrotron investigation

    International Nuclear Information System (INIS)

    Sanderson, Peter; Naidu, Ravi; Bolan, Nanthi; Lim, Jung Eun; Ok, Yong Sik

    2015-01-01

    Highlights: • Quantitative speciation of Pb by XAS as a result of Phosphate and MgO treatment revealed Pb converted to pyromorphite was limited. • Subsequent MgO addition increased pyromorphite formation. • Pb was precipitated on the surface of MgO as PbO. • Bioaccessibility of Pb decreased with P treatments, but not with MgO only. - Abstract: Three Australian shooting range soils were treated with phosphate and magnesium oxide, or a combination of both to chemically stabilize Pb. Lead speciation was determined after 1 month ageing by X-ray absorption spectroscopy combined with linear combination fitting in control and treated soils. The predominant Pb species in untreated soils were iron oxide bound Pb, humic acid bound Pb and the mineral litharge. Treatment with phosphate resulted in substantial pyromorphite formation in two of the soils (TV and PE), accounting for up to 38% of Pb species present, despite the addition of excess phosphate. In MgO treated soils only, up to 43% of Pb was associated with MgO. Litharge and Pb hydroxide also formed as a result of MgO addition in the soils. Application of MgO after P treatment increased hydroxypyromorphite/pyromorphite formation relative to soils teated with phosphate only. X-ray diffraction and Scanning electron microscopy revealed PbO precipitate on the surface of MgO. Soil pH, (5.3–9.3) was an important parameter, as was the solubility of existing Pb species. The use of direct means of determination of the stabilisation of metals such as by X-ray absorption spectroscopy is desirable, particularly in relation to understanding long term stability of the immobilised contaminants.

  20. Chemical stabilisation of lead in shooting range soils with phosphate and magnesium oxide: Synchrotron investigation

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, Peter [Centre for Environmental Risk Assessment and Remediation and CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of South Australia, University Parade, 5095 Mawson Lakes (Australia); Naidu, Ravi, E-mail: ravi.naidu@crccare.com [Centre for Environmental Risk Assessment and Remediation and CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of South Australia, University Parade, 5095 Mawson Lakes (Australia); Bolan, Nanthi [Centre for Environmental Risk Assessment and Remediation and CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of South Australia, University Parade, 5095 Mawson Lakes (Australia); Lim, Jung Eun; Ok, Yong Sik [Korea Biochar Research Center & Department of Biological Environment, Kangwon National University, Chuncheon 200-701 (Korea, Republic of)

    2015-12-15

    Highlights: • Quantitative speciation of Pb by XAS as a result of Phosphate and MgO treatment revealed Pb converted to pyromorphite was limited. • Subsequent MgO addition increased pyromorphite formation. • Pb was precipitated on the surface of MgO as PbO. • Bioaccessibility of Pb decreased with P treatments, but not with MgO only. - Abstract: Three Australian shooting range soils were treated with phosphate and magnesium oxide, or a combination of both to chemically stabilize Pb. Lead speciation was determined after 1 month ageing by X-ray absorption spectroscopy combined with linear combination fitting in control and treated soils. The predominant Pb species in untreated soils were iron oxide bound Pb, humic acid bound Pb and the mineral litharge. Treatment with phosphate resulted in substantial pyromorphite formation in two of the soils (TV and PE), accounting for up to 38% of Pb species present, despite the addition of excess phosphate. In MgO treated soils only, up to 43% of Pb was associated with MgO. Litharge and Pb hydroxide also formed as a result of MgO addition in the soils. Application of MgO after P treatment increased hydroxypyromorphite/pyromorphite formation relative to soils teated with phosphate only. X-ray diffraction and Scanning electron microscopy revealed PbO precipitate on the surface of MgO. Soil pH, (5.3–9.3) was an important parameter, as was the solubility of existing Pb species. The use of direct means of determination of the stabilisation of metals such as by X-ray absorption spectroscopy is desirable, particularly in relation to understanding long term stability of the immobilised contaminants.

  1. Common ECG Lead Placement Errors. Part I: Limb Lead Reversals

    Directory of Open Access Journals (Sweden)

    Allison V. Rosen

    2015-10-01

    Full Text Available Background: Electrocardiography (ECG is a very useful diagnostic tool. However, errors in placement of ECG leads can create artifacts, mimic pathologies, and hinder proper ECG interpretation. It is important for members of the health care team to be able to recognize the common patterns resulting from lead placement errors. Methods: 12-lead ECGs were recorded in a single male healthy subject in his mid 20s. Six different limb lead reversals were compared to ECG recordings from correct lead placement. Results: Classic ECG patterns were observed when leads were reversed. Methods of discriminating these ECG patterns from true pathologic findings were described. Conclusion: Correct recording and interpretation of ECGs is key to providing optimal patient care. It is therefore crucial to be able to recognize common ECG patterns that are indicative of lead reversals.

  2. LEADING WITH LEADING INDICATORS

    International Nuclear Information System (INIS)

    PREVETTE, S.S.

    2005-01-01

    This paper documents Fluor Hanford's use of Leading Indicators, management leadership, and statistical methodology in order to improve safe performance of work. By applying these methods, Fluor Hanford achieved a significant reduction in injury rates in 2003 and 2004, and the improvement continues today. The integration of data, leadership, and teamwork pays off with improved safety performance and credibility with the customer. The use of Statistical Process Control, Pareto Charts, and Systems Thinking and their effect on management decisions and employee involvement are discussed. Included are practical examples of choosing leading indicators. A statistically based color coded dashboard presentation system methodology is provided. These tools, management theories and methods, coupled with involved leadership and employee efforts, directly led to significant improvements in worker safety and health, and environmental protection and restoration at one of the nation's largest nuclear cleanup sites

  3. Secondary lead production

    Energy Technology Data Exchange (ETDEWEB)

    Hollis, R.G.

    1990-10-16

    This invention is concerned with the efficient recovery of soft lead from the paste component of used automobile lead-acid storage batteries. According to the invention, a scrap which contains lead oxide, lead sulfate, and antimony in an oxidized state is processed in the following steps to recover lead. A refractory lined reaction vessel is continuously charged with the scrap, along with a reductant effective for reducing lead oxide. The charged material is melted and agitated by means of a submerged lance at 900-1150{degree}C whereby some of the lead oxide of the scrap is reduced to form molten lead. A slag layer is then formed above the molten lead, and an amount of lead oxide is maintained in the slag layer. The molten lead, now containing under 0.5 wt % of antimony, is removed, and the antimony oxide in the scrap is concentrated as oxide in the slag layer. Preferred embodiments of the invention result in the production, in a single step, of a soft lead substantially free of antimony. The slag may be subsequently treated to reduce the antimony oxide and produce a valuable antimony-lead product. Further advantages of the process are that a wet battery paste may be used as the feed without prior drying, and the process can be conducted at a temperature 100-150{degree}C lower than in previously known methods. In addition, a smaller reactor can be employed which reduces both capital cost and fuel costs. The process of the invention is illustrated by descriptions of pilot plant tests. 1 fig.

  4. Comparison of the properties of tonpilz transducers fabricated with 001 fiber-textured lead magnesium niobate-lead titanate ceramic and single crystals.

    Science.gov (United States)

    Brosnan, Kristen H; Messing, Gary L; Markley, Douglas C; Meyer, Richard J

    2009-11-01

    Tonpilz transducers are fabricated from 001 fiber-textured 0.72Pb(Mg(1/3)Nb(2/3))O(3)-0.28PbTiO(3) (PMN-28PT) ceramics, obtained by the templated grain growth process, and PMN-28PT ceramic and Bridgman grown single crystals of the same composition. In-water characterization of single element transducers shows higher source levels, higher in-water coupling, and more usable bandwidth for the 81 vol % textured PMN-28PT device than for the ceramic PMN-28PT element. The 81 vol % textured PMN-28PT tonpilz element measured under large signals shows linearity in sound pressure levels up to 0.23 MV/m drive field but undergoes a phase transition due to a lowered transition temperature from the SrTiO(3) template particles. Although the textured ceramic performs well in this application, it could be further improved with compositional tailoring to raise the transition temperature and better processing to improve the texture quality. With these improvements textured piezoelectric ceramics will be viable options for medical ultrasound, actuators, and sonar applications because of their ease of processing, compositional homogeneity, and potentially lower cost than single crystal.

  5. Lake sediments record prehistoric lead pollution related to early copper production in North America.

    Science.gov (United States)

    Pompeani, David P; Abbott, Mark B; Steinman, Byron A; Bain, Daniel J

    2013-06-04

    The mining and use of copper by prehistoric people on Michigan's Keweenaw Peninsula is one of the oldest examples of metalworking. We analyzed the concentration of lead, titanium, magnesium, iron, and organic matter in sediment cores recovered from three lakes located near mine pits to investigate the timing, location, and magnitude of ancient copper mining pollution. Lead concentrations were normalized to lithogenic metals and organic matter to account for processes that can influence natural (or background) lead delivery. Nearly simultaneous lead enrichments occurred at Lake Manganese and Copper Falls Lake ∼8000 and 7000 years before present (yr BP), indicating that copper extraction occurred concurrently in at least two locations on the peninsula. The poor temporal coherence among the lead enrichments from ∼6300 to 5000 yr BP at each lake suggests that the focus of copper mining and annealing shifted through time. In sediment younger than ∼5000 yr BP, lead concentrations remain at background levels at all three lakes, excluding historic lead increases starting ∼150 yr BP. Our work demonstrates that lead emissions associated with both the historic and Old Copper Complex tradition are detectable and can be used to determine the temporal and geographic pattern of metal pollution.

  6. Effect of Magnesium Hydride on the Corrosion Behavior of Pure Magnesium in 0.1 M NaCl Solution

    Directory of Open Access Journals (Sweden)

    Shanna Xu

    2010-01-01

    Full Text Available The effect of magnesium hydride on the corrosion behavior of pure magnesium in 0.1 M NaCl solution was investigated using the gas collection method, potentiostatic current decay test, and in situ Raman spectrum. The formation of magnesium hydride (MgH2, Mg2H4 was observed at the cathodic region. Applying anodic potential leads to decomposition of magnesium hydride. Magnesium hydride plays an important role on the negative difference effect (NDE in both the cathodic and anodic regions.

  7. Kinetics of oil saponification by lead salts in ancient preparations of pharmaceutical lead plasters and painting lead mediums.

    Science.gov (United States)

    Cotte, M; Checroun, E; Susini, J; Dumas, P; Tchoreloff, P; Besnard, M; Walter, Ph

    2006-12-15

    Lead soaps can be found in archaeological cosmetics as well as in oil paintings, as product of interactions of lead salts with oil. In this context, a better understanding of the formation of lead soaps allows a follow-up of the historical evolution of preparation recipes and provides new insights into conservation conditions. First, ancient recipes of both pharmaceutical lead plasters and painting lead mediums, mixtures of oil and lead salts, were reconstructed. The ester saponification by lead salts is determined by the preparation parameters which were quantified by FT-IR spectrometry. In particular, ATR/FT-IR spectrometer was calibrated by the standard addition method to quantitatively follow the kinetics of this reaction. The influence of different parameters such as temperature, presence of water and choice of lead salts was assessed: the saponification is clearly accelerated by water and heating. This analysis provides chemical explanations to the historical evolution of cosmetic and painting preparation recipes.

  8. Lead levels - blood

    Science.gov (United States)

    Blood lead levels ... is used to screen people at risk for lead poisoning. This may include industrial workers and children ... also used to measure how well treatment for lead poisoning is working. Lead is common in the ...

  9. Lead and osteoporosis: Mobilization of lead from bone in postmenopausal women

    Energy Technology Data Exchange (ETDEWEB)

    Silbergeld, E.K. (Environmental Defense Fund, WA (USA)); Schwartz, J. (Environmental Protection Agency, Washington, DC (USA)); Mahaffey, K. (National Institute of Environmental Health Sciences, Research Triangle Park, NC (USA))

    1988-10-01

    Although it has been known that humans accumulate lead in bone, mineralized tissue has been considered primarily as a sequestering compartment and not as a site of toxic action for lead. However, experimental data indicate that bone lead can be released during conditions of demineralization, such as pregnancy and lactation. We have examined lead status in women, before and after menopause, using the NHANES II dataset compiled between 1976 and 1980. In 2981 black and white women there was a highly significant increase in both whole blood and calculated plasma lead concentrations after menopause. The results indicate that bone lead is not an inert storage site for absorbed lead. Moreover, lead may interact with other factors in the course of postmenopausal osteoporosis, to aggravate the course of the disease, since lead is known to inhibit activation of vitamin D, uptake of dietary calcium, and several regulatory aspects of bone cell function. The consequences of this mobilization may also be of importance in assessing the risks of maternal lead exposure to fetal and infant health.

  10. Towards bio monitoring of toxic (lead) and essential elements in whole blood from 1- to 72-month old children: a cross-sectional study.

    Science.gov (United States)

    Kang-Sheng, Liu; Xiao-Dong, Mao; Juan, Shi; Chun-Fan, Dai; Pingqing, Gu

    2015-06-01

    Minerals such as zinc, copper, selenium, calcium, and magnesium are essential for normal human development and functioning of the body. They have been found to play important roles in immuno-physiologic functions. The study is to evaluate the distribution and correlation of nonessential (lead) and essential elements in whole blood from 1- to 72-month old children. The cross-sectional study was performed in 1551 children. Six element concentrations, including copper (Cu), zinc (Zn), calcium (Ca), magnesium (Mg), iron (Fe) and lead (Pb) in the blood were determined by atomic absorption spectrometry. Distributions and correlations of trace elements in different age groups were analyzed and compared. A Pearson correlation controlled for age and gender was used to assess the relationship of non essential (lead) and essential elements. Levels of copper and magnesium were 18.09 ± 4.42 µmol/L and 1.42 ± 0.12 mmol/L, respectively. 6.04% of all children showed copper levels below the normal threshold, the levels of Magnesium were stable in different age groups. Though the overall mean blood zinc and iron concentrations (61.19 ± 11.30 µmol/L and 8.24 ± 0.59 mmol/L, respectively) gradually increased with age and the overall deficiency levels (24.1% and 36.0%, respectively) decreased with age, zinc and iron deficiencies were still very stable. Controlling for gender and age, significant positive correlations were found when comparing copper to zinc, calcium, magnesium, and iron ((r = 0.333, 0.241, 0.417, 0.314 ,p lead levels (41.16 ± 16.10) were relatively unstable among different age groups. The prevalence of lead intoxication in all children was 1.3% .Calcium levels decreased gradually with age, with an overall concentration of 1.78 ± 0.13 mmol/L. Significant negative correlations were also noted between Pb and Zn, Fe (r = -0.179, -0.124.p lead intoxication in all the children studied was low; The established reference intervals for Cu, Zn, Ca and Mg provide an

  11. Safe leads and lead changes in competitive team sports

    Science.gov (United States)

    Clauset, A.; Kogan, M.; Redner, S.

    2015-06-01

    We investigate the time evolution of lead changes within individual games of competitive team sports. Exploiting ideas from the theory of random walks, the number of lead changes within a single game follows a Gaussian distribution. We show that the probability that the last lead change and the time of the largest lead size are governed by the same arcsine law, a bimodal distribution that diverges at the start and at the end of the game. We also determine the probability that a given lead is "safe" as a function of its size L and game time t . Our predictions generally agree with comprehensive data on more than 1.25 million scoring events in roughly 40 000 games across four professional or semiprofessional team sports, and are more accurate than popular heuristics currently used in sports analytics.

  12. [Environmental lead poisoning from lead-glazed earthenware used for storing drinks].

    Science.gov (United States)

    Sabouraud, S; Coppéré, B; Rousseau, C; Testud, F; Pulce, C; Tholly, F; Blanc, M; Culoma, F; Facchin, A; Ninet, J; Chambon, P; Medina, B; Descotes, J

    2009-12-01

    Current unusual environmental sources of lead exposure mainly include traditional medicines, either ayurvedic remedies or others, traditional cosmetics (kohl, surma), and the use of traditional earthenware, for storage or cooking. We report two cases of lead poisoning in adults initially identified by paroxysmal abdominal pain or anemia. In both cases, the environmental investigation evidenced one main source of lead exposure, namely a lead-glazed earthenware jug in which a drink was stored, "kefir" in the first case, and "kombucha" tea in the second one. It is recommended to search for lead intoxication in patients with unexplained anemia. Environmental sources of lead can be multiple. Their relative importance has to be ranked during the environmental investigation and among these, lead-glazed earthenware must be considered as a source of high lead exposure when drinks are stored inside and thus can soak.

  13. Lead pollution: lead content in milk from cows fed on contaminated forages

    Energy Technology Data Exchange (ETDEWEB)

    Sapetti, C; Arduino, E; Durio, P

    1973-01-01

    Lead toxicity is reviewed, and the history of the lead poisoning is described. Much of the lead pollution in soil is due to automobile exhaust. Two milk cows were fed forage with added lead acetate. The 20 kg of lead corresponded to 50 ppm, a level that is often found in hays near major highways. The cows milk was then analyzed for lead content. During the first and second phase of administration of lead salts, the milk cows did not show any evident symptoms of intoxication. The lead in the milk did have a marked correlation with the administered lead. The lead doses did not last long enough for chronic symptoms to begin. The dosage of lead in milk, due to the facility of drawing samples and the relevant levels of response, could represent a valid method for diagnosing incipient chronic intoxications.

  14. Effect measure modification of blood lead-air lead slope factors.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Meng, Qingyu; Cohen, Jonathan; Davis, J Allen; Svendsgaard, David; Brown, James S; Tuttle, Lauren; Hubbard, Heidi; Rice, Joann; Kirrane, Ellen; Vinikoor-Imler, Lisa; Kotchmar, Dennis; Hines, Erin; Ross, Mary

    2015-01-01

    There is abundant literature finding that susceptibility factors, including race and ethnicity, age, and housing, directly influence blood lead levels. No study has explored how susceptibility factors influence the blood lead-air lead relationship nationally. The objective is to evaluate whether susceptibility factors act as effect measure modifiers on the blood lead-air lead relationship. Participant level blood lead data from the 1999 to 2008 National Health and Nutrition Examination Survey were merged with air lead data from the US Environmental Protection Agency. Linear mixed effects models were run with and without an air lead interaction term for age group, sex, housing age, or race/ethnicity to determine whether these factors are effect measure modifiers for all ages combined and for five age brackets. Age group and race/ethnicity were determined to be effect measure modifiers in the all-age model and for some age groups. Being a child (1-5, 6-11, and 12-19 years) or of Mexican-American ethnicity increased the effect estimate. Living in older housing (built before 1950) decreased the effect estimate for all models except for the 1-5-year group, where older housing was an effect measure modifier. These results are consistent with the peer-reviewed literature of time-activity patterns, ventilation, and toxicokinetics.

  15. Lead - nutritional considerations

    Science.gov (United States)

    ... billion people had toxic (poisonous) blood lead levels. Food Sources Lead can be found in canned goods if there is lead solder in the ... to bottled water for drinking and cooking. Avoid canned goods from foreign ... cans goes into effect. If imported wine containers have a lead foil ...

  16. The refining of secondary lead for use in advanced lead-acid batteries

    International Nuclear Information System (INIS)

    Ellis, Timothy W.; Mirza, Abbas H.

    2010-01-01

    Secondary lead, i.e. material produced by the recycling of lead-acid batteries has become the primary source of lead in much of the world. This has been important to the secondary lead industry as other uses have dwindled, e.g. lead based pigments, chemicals, fuel additives, solders and CRT glasses. Presently, battery manufacturing accounts for greater than 80% of lead consumption while recycled lead accounts for approximately the same market share of lead supply. These two facts strongly demonstrate the battery manufacturing and recycled lead are intimately coupled in everyday life. In this paper we will explore how recycled lead has become the material of choice for battery construction through the development of a recovery and refining process that exceeds the industries requirements. Particular focus will be on addressing the results presented by Prengaman on the effects of contaminant or tramp elements on gassing in lead-acid batteries. (author)

  17. The effect of lead-based paint hazard remediation on blood lead levels of lead poisoned children in New York City.

    Science.gov (United States)

    Leighton, Jessica; Klitzman, Susan; Sedlar, Slavenka; Matte, Thomas; Cohen, Neal L

    2003-07-01

    Despite the widespread use of lead paint hazard control for children with lead poisoning, few controlled studies that estimate the effect of such control on children's blood lead levels have been published. This retrospective follow-up study examined the effects of lead hazard remediation and its timing on the blood lead levels of lead-poisoned children. From the New York City child blood lead registry, 221 children were selected who had an initial blood lead level of 20-44 micro g/dL between 1 July 1994 and 31 December 1996; were 6 months to 6 years of age; had a report of a follow-up blood lead test between 10 and 14 months after the initial test; had a lead-based paint hazard identified in the primary dwelling unit prior to the 10- to 14-month follow-up blood lead test; had resided or spent time at only one address with an identified lead-based paint hazard; and were not chelated. The decline in geometric mean blood lead levels from baseline to 10-14 months later was compared for children whose homes were remediated and whose homes were not remediated during the follow-up period. Regardless of remediation, geometric mean blood lead levels declined significantly from 24.3 micro g/dL at the initial diagnosis to 12.3 micro g/dL at the 10- to 14-month follow-up blood lead test (Premediated the geometric mean blood lead levels declined 53% compared to 41% among the 75 children whose homes were not remediated by the follow-up blood lead test, a remediation effect of approximately 20% (Premediation effect was 11%, although it was no longer significant. Race was the only factor that appeared to confound the relationship: Black children had higher follow-up blood lead levels even after controlling for other factors, including the natural logarithm of the initial blood lead level. The effect of remediation appeared to be stronger for younger (10 to remediation (within less than 3 months) appeared to have greater declines in blood lead levels at the follow-up test than

  18. Melatonin reduces lead levels in blood, brain and bone and increases lead excretion in rats subjected to subacute lead treatment.

    Science.gov (United States)

    Hernández-Plata, Everardo; Quiroz-Compeán, Fátima; Ramírez-Garcia, Gonzalo; Barrientos, Eunice Yáñez; Rodríguez-Morales, Nadia M; Flores, Alberto; Wrobel, Katarzina; Wrobel, Kazimierz; Méndez, Isabel; Díaz-Muñoz, Mauricio; Robles, Juvencio; Martínez-Alfaro, Minerva

    2015-03-04

    Melatonin, a hormone known for its effects on free radical scavenging and antioxidant activity, can reduce lead toxicity in vivo and in vitro.We examined the effects of melatonin on lead bio-distribution. Rats were intraperitoneally injected with lead acetate (10, 15 or 20mg/kg/day) with or without melatonin (10mg/kg/day) daily for 10 days. In rats intoxicated with the highest lead doses, those treated with melatonin had lower lead levels in blood and higher levels in urine and feces than those treated with lead alone, suggesting that melatonin increases lead excretion. To explore the mechanism underlying this effect, we first assessed whether lead/melatonin complexes were formed directly. Electronic density functional (DFT) calculations showed that a lead/melatonin complex is energetically feasible; however, UV spectroscopy and NMR analysis showed no evidence of such complexes. Next, we examined the liver mRNA levels of metallothioneins (MT) 1 and 2. Melatonin cotreatment increased the MT2 mRNA expression in the liver of rats that received the highest doses of lead. The potential effects of MTs on the tissue distribution and excretion of lead are not well understood. This is the first report to suggest that melatonin directly affects lead levels in organisms exposed to subacute lead intoxication. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Lead elimination by ICRF 158 in rats after chronic lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    Witting, U; Hultsch, E

    1981-02-01

    Lead elimination by ICRF 158, a lipophilic derivative of ethylene-diaminetetra-acetate (EDTA), was investigated in rats after chronic lead exposure. The animals had received a lead concentration of 550 ppm in their drinking water for 140 days. Subsequent treatment with ICRF 158 for 30 days led to increased mobilization and elimination of incorporated lead, and the lead-induced inhibition of hemosynthesis was removed. ICR 158 produced no renal damage in excess to lead-induced tubular nephrosis. Separate toxicity tests in mice demonstrated that is less toxic than CaNa/sub 2/EDTA. ICRF 158 does not form stable complexes with lead ions in vitro. The mechanism of action of this lipophilic EDTA derivative is compared to that of its hydrophilic correspondent, the chelating agent CaNa/sub 2/EDTA.

  20. Cryogenic current leads

    Energy Technology Data Exchange (ETDEWEB)

    Zizek, F.

    1982-01-01

    Theoretical, technical and design questions are examined of cryogenic current leads for SP of magnetic systems. Simplified mathematical models are presented for the current leads. To illustrate modeling, the calculation is made of the real current leads for 500 A and three variants of current leads for 1500 A for the enterprise ''Shkoda.''

  1. The effect of lead-based paint hazard remediation on blood lead levels of lead poisoned children in New York City

    International Nuclear Information System (INIS)

    Leighton, Jessica; Klitzman, Susan; Sedlar, Slavenka; Matte, Thomas; Cohen, Neal L.

    2003-01-01

    Despite the widespread use of lead paint hazard control for children with lead poisoning, few controlled studies that estimate the effect of such control on children's blood lead levels have been published. This retrospective follow-up study examined the effects of lead hazard remediation and its timing on the blood lead levels of lead-poisoned children. From the New York City child blood lead registry, 221 children were selected who had an initial blood lead level of 20-44 μg/dL between 1 July 1994 and 31 December 1996; were 6 months to 6 years of age; had a report of a follow-up blood lead test between 10 and 14 months after the initial test; had a lead-based paint hazard identified in the primary dwelling unit prior to the 10- to 14-month follow-up blood lead test; had resided or spent time at only one address with an identified lead-based paint hazard; and were not chelated. The decline in geometric mean blood lead levels from baseline to 10-14 months later was compared for children whose homes were remediated and whose homes were not remediated during the follow-up period. Regardless of remediation, geometric mean blood lead levels declined significantly from 24.3 μg/dL at the initial diagnosis to 12.3 μg/dL at the 10- to 14-month follow-up blood lead test (P<0.01). Among the 146 children whose homes were remediated the geometric mean blood lead levels declined 53% compared to 41% among the 75 children whose homes were not remediated by the follow-up blood lead test, a remediation effect of approximately 20% (P<0.01). After adjusting for potential confounders, the remediation effect was 11%, although it was no longer significant. Race was the only factor that appeared to confound the relationship: Black children had higher follow-up blood lead levels even after controlling for other factors, including the natural logarithm of the initial blood lead level. The effect of remediation appeared to be stronger for younger (10 to <36 months old) than for older (36

  2. Work function of oxygen exposed lead and lead/indium alloy films

    International Nuclear Information System (INIS)

    Gundlach, K.H.; Hellemann, H.P.; Hoelzl, J.

    1982-01-01

    The effect of indium in superconducting tunnel junctions with lead/indium alloy base electrodes is investigated by measuring the vacuum work function of lead, indium, and lead/indium alloy films. It is found that the anomalous decrease of the work function of lead upon exposure to oxygen, explained by the penetration of oxygen into the inner surface of the lead film, is reversed into a slight increase in work function when some indium is added to the lead. This result indicates that the addition of indium provides a protection by suppressing the penetration of oxygen (and probably other gases) into the interior of the thin film

  3. Blood lead and lead-210 origins in residents of Toulouse

    International Nuclear Information System (INIS)

    Servant, J.; Delapart, M.

    1981-01-01

    Blood lead and lead-210 analyses were performed on blood samples from non-smoking residents of Toulouse (city of 400,000 inhabitants). Simultaneous surface soil lead content determinations were carried out by the same procedure on rural zone samples of southwestern France. The observed isotopic ratios were compared in order to evaluate food chain contamination. For an average of 19.7 +- 5.8 μg 100 cc -1 of lead in blood, atmospheric contamination amounts to 20%, estimated as follows: 6% from direct inhalation and 14% from dry deposits on vegetation absorbed as food. The natural levels carried over by the food chain reach 14.9 μg 100 cc -1 and have a 210 Pb/Pb concentration ratio of 0.055 dpmμg -1 . These results lead to a maximum value of 15 μg 100 cc -1 for natural lead in human blood according to the ICRP model. (author)

  4. Lead-Free Piezoelectrics

    CERN Document Server

    Nahm, Sahn

    2012-01-01

    Ecological restrictions in many parts of the world are demanding the elimination of Pb from all consumer items. At this moment in the piezoelectric ceramics industry, there is no issue of more importance than the transition to lead-free materials. The goal of Lead-Free Piezoelectrics is to provide a comprehensive overview of the fundamentals and developments in the field of lead-free materials and products to leading researchers in the world. The text presents chapters on demonstrated applications of the lead-free materials, which will allow readers to conceptualize the present possibilities and will be useful for both students and professionals conducting research on ferroelectrics, piezoelectrics, smart materials, lead-free materials, and a variety of applications including sensors, actuators, ultrasonic transducers and energy harvesters.

  5. Lead Toxicity

    Science.gov (United States)

    ... o Do not use glazed ceramics, home remedies, cosmetics, or leaded-crystal glassware unless you know that they are lead safe. o If you live near an industry, mine, or waste site that may have contaminated ...

  6. The lead and lead-acid battery industries during 2002 and 2007 in China

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.Y.; Li, A.J.; Finlow, D.E. [Key Lab of Electrochemical Technology on Energy Storage and Power Generation in Guangdong Universities, School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China)

    2009-06-01

    In the past 15 years, the center of the international lead market has shifted to China. China has become the largest producer of raw and refined lead, plus the largest consumer. This paper reviews the status of the lead and lead-acid battery industries in China, including lead mining, lead refining, secondary lead production, the lead-acid battery industry, new opportunities for lead-acid batteries, and the environmental problems associated with lead and lead-acid batteries. The output of raw and refined lead has increased annually in China, and now accounts for more than 30% of the world total. As a result of a change in the Chinese government's policy regarding the export of lead, plus an increase in the price of lead, the profits of Chinese lead manufacturers were significantly reduced, the trade deficit of the Chinese lead industry increased, the operating rates of lead smelter enterprises greatly reduced, and some small enterprises were forced to shut down. At the present time, an increasing number of enterprises have begun to produce secondary lead, and the scale of production has expanded from tens of tons to tens of thousands of tons. In 2006, the output of secondary lead in China reached 700,000 tons, but outdated technology and equipment limited development of the secondary lead industry. Because of serious pollution problems, raw material shortages, and fierce price competition in the battery market, changes in the development of the lead-acid battery industry have been dramatic; approximately one thousand medium-sized and small lead-acid battery producers have been closed in the past 3 years. The output of large lead-acid battery enterprises has not been reduced, however, as a result of their manufacturing technology and equipment being comparable to those in other advanced industrial countries. In China, the flourishing development of electric bicycles, electric tricycles, and photovoltaic energy systems should provide ongoing opportunities for

  7. The lead and lead-acid battery industries during 2002 and 2007 in China

    International Nuclear Information System (INIS)

    Chen, H.Y.; Li, A.J.; Finlow, D.E.

    2009-01-01

    In the past 15 years, the center of the international lead market has shifted to China. China has become the largest producer of raw and refined lead, plus the largest consumer. This paper reviews the status of the lead and lead-acid battery industries in China, including lead mining, lead refining, secondary lead production, the lead-acid battery industry, new opportunities for lead-acid batteries, and the environmental problems associated with lead and lead-acid batteries. The output of raw and refined lead has increased annually in China, and now accounts for more than 30% of the world total. As a result of a change in the Chinese government's policy regarding the export of lead, plus an increase in the price of lead, the profits of Chinese lead manufacturers were significantly reduced, the trade deficit of the Chinese lead industry increased, the operating rates of lead smelter enterprises greatly reduced, and some small enterprises were forced to shut down. At the present time, an increasing number of enterprises have begun to produce secondary lead, and the scale of production has expanded from tens of tons to tens of thousands of tons. In 2006, the output of secondary lead in China reached 700,000 tons, but outdated technology and equipment limited development of the secondary lead industry. Because of serious pollution problems, raw material shortages, and fierce price competition in the battery market, changes in the development of the lead-acid battery industry have been dramatic; approximately one thousand medium-sized and small lead-acid battery producers have been closed in the past 3 years. The output of large lead-acid battery enterprises has not been reduced, however, as a result of their manufacturing technology and equipment being comparable to those in other advanced industrial countries. In China, the flourishing development of electric bicycles, electric tricycles, and photovoltaic energy systems should provide ongoing opportunities for the

  8. A green lead hydrometallurgical process based on a hydrogen-lead oxide fuel cell.

    Science.gov (United States)

    Pan, Junqing; Sun, Yanzhi; Li, Wei; Knight, James; Manthiram, Arumugam

    2013-01-01

    The automobile industry consumed 9 million metric tons of lead in 2012 for lead-acid batteries. Recycling lead from spent lead-acid batteries is not only related to the sustainable development of the lead industry, but also to the reduction of lead pollution in the environment. The existing lead pyrometallurgical processes have two main issues, toxic lead emission into the environment and high energy consumption; the developing hydrometallurgical processes have the disadvantages of high electricity consumption, use of toxic chemicals and severe corrosion of metallic components. Here we demonstrate a new green hydrometallurgical process to recover lead based on a hydrogen-lead oxide fuel cell. High-purity lead, along with electricity, is produced with only water as the by-product. It has a >99.5% lead yield, which is higher than that of the existing pyrometallurgical processes (95-97%). This greatly reduces lead pollution to the environment.

  9. Lead Contamination and Microbial Lead Tolerance in Soils at Major ...

    African Journals Online (AJOL)

    Devika

    ABSTRACT: Lead pollution and lead tolerance levels of microbes in soil at major road junctions in Benin. City were investigated. Results revealed that distance from the road junctions affected the concentrations of lead in soil, as well as the microbial population density and types of microbes present in the soil. The highest ...

  10. Lead Contamination and Microbial Lead Tolerance in Soils at Major ...

    African Journals Online (AJOL)

    Lead pollution and lead tolerance levels of microbes in soil at major road junctions in Benin City were investigated. Results revealed that distance from the road junctions affected the concentrations of lead in soil, as well as the microbial population density and types of microbes present in the soil. The highest concentrations ...

  11. The effects of thiamin on lead metabolism: organ distribution of lead 203.

    Science.gov (United States)

    Kim, J S; Hamilton, D L; Blakley, B R; Rousseaux, C G

    1992-01-01

    The effect of thiamin on the organ distribution of lead was evaluated in CD-1 mice exposed intragastrically or intraperitoneally to a single dose of lead acetate (100 micrograms) containing 100 microCi lead 203. They were treated with either thiamin (25 or 50 mg/kg body weight), calcium ethylenediaminetetraacetic acid (CaEDTA) (50 mg/kg body weight), or combinations of thiamin and CaEDTA. The whole body retention and the organ distribution of lead 203 varied depending upon the route of lead administration, dose of thiamin and the specific treatment combination. Thiamin (25 or 50 mg/kg) treatment increased the whole body retention of both intragastric and intraperitoneal lead by approximately 10% in each instance. Calcium ethylenediaminetetraacetic acid, either alone or in combination with thiamin (50 mg/kg) reduced the whole body retention of lead by as much as 14% regardless of route of lead exposure. The relative retention of lead by the liver, kidney and spleen was greater in mice exposed to lead by the intragastric route. Regardless of route, CaEDTA in the combined treatment reduced the relative retention of lead in both the liver and kidney, whereas thiamin alone only reduced the retention of lead in the kidney. The results of this study indicate that thiamin in combination with CaEDTA alters the distribution and retention of lead in a manner which may have therapeutic application as it relates to chelation therapy. PMID:1423063

  12. Lead shot from hunting as a source of lead in human blood

    International Nuclear Information System (INIS)

    Johansen, Poul; Pedersen, Henning Sloth; Asmund, Gert; Riget, Frank

    2006-01-01

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 μg/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 μg/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood

  13. Lead shot from hunting as a source of lead in human blood

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, Poul [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: poj@dmu.dk; Pedersen, Henning Sloth [Primary Health Care Center, DK-3900 Nuuk (Greenland); Asmund, Gert [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Riget, Frank [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2006-07-15

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 {mu}g/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 {mu}g/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood.

  14. The leaching of lead from lead-based paint in landfill environments.

    Science.gov (United States)

    Wadanambi, Lakmini; Dubey, Brajesh; Townsend, Timothy

    2008-08-30

    Lead leaching from lead-based paint (LBP) was examined using standardized laboratory protocols and tests with leachate from actual and simulated landfill environments. Two different LBP samples were tested; leaching solutions included leachates from three municipal solid waste (MSW) landfills and three construction and demolition (C&D) debris landfills. The toxicity characteristic leaching procedure (TCLP) and the synthetic precipitation leaching procedure (SPLP) were also performed. Lead concentrations were many times higher using the TCLP compared to the SPLP and the landfill leachates. No significant difference (alpha=0.05) was observed in leached lead concentrations from the MSW landfill and C&D debris landfill leachates. The impact of other building materials present in LBP debris on lead leaching was examined by testing mixtures of LBP (2%) and different building materials (98%; steel, wood, drywall, concrete). The type of substrate present impacted lead leaching results, with concrete demonstrating the most dramatic impact; the lowest lead concentrations were measured in the presence of concrete under both TCLP and SPLP extractions.

  15. Relationship between soil lead and airborne lead concentrations at Springfield, Missouri, USA

    Energy Technology Data Exchange (ETDEWEB)

    Sheets, R W; Kyger, J R; Biagioni, R N; Probst, S [Department of Chemistry, Southwest Missouri State University, 65804 Springfield, MO (United States); Boyer, R; Barke, K [Greene County Health Department, 65802 Springfield, MO (United States)

    2001-04-23

    This study tests whether lead deposited to soil from automobiles during past years in a medium-sized US city (population 150000) may present a current health risk. It examines the relationship between current soil lead concentrations at nine locations within the city of Springfield, Missouri, and airborne lead levels measured at the same locations during years (1975-1981) when lead emissions from automobiles were much greater than at present. A strong, significant correlation is found between soil and airborne lead levels at eight of the sites (r=0.91, P<0.005 for soil lead vs. 1979 airborne lead), in low-traffic areas as well as in areas adjacent to heavy traffic flow. Residual lead concentrations in these soils are relatively low, even for the high-traffic sites, as expected for a medium sized city.

  16. Corrosion by liquid lead and lead-bismuth: experimental results review and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jinsuo [Los Alamos National Laboratory

    2008-01-01

    Liquid metal technologies for liquid lead and lead-bismuth alloy are under wide investigation and development for advanced nuclear energy systems and waste transmutation systems. Material corrosion is one of the main issues studied a lot recently in the development of the liquid metal technology. This study reviews corrosion by liquid lead and lead bismuth, including the corrosion mechanisms, corrosion inhibitor and the formation of the protective oxide layer. The available experimental data are analyzed by using a corrosion model in which the oxidation and scale removal are coupled. Based on the model, long-term behaviors of steels in liquid lead and lead-bismuth are predictable. This report provides information for the selection of structural materials for typical nuclear reactor coolant systems when selecting liquid lead or lead bismuth as heat transfer media.

  17. Relationship between soil lead and airborne lead concentrations at Springfield, Missouri, USA.

    Science.gov (United States)

    Sheets, R W; Kyger, J R; Biagioni, R N; Probst, S; Boyer, R; Barke, K

    2001-04-23

    This study tests whether lead deposited to soil from automobiles during past years in a medium-sized US city (population 150,000) may present a current health risk. It examines the relationship between current soil lead concentrations at nine locations within the city of Springfield, Missouri, and airborne lead levels measured at the same locations during years (1975-1981) when lead emissions from automobiles were much greater than at present. A strong, significant correlation is found between soil and airborne lead levels at eight of the sites (r = 0.91, P lead vs. 1979 airborne lead), in low-traffic areas as well as in areas adjacent to heavy traffic flow. Residual lead concentrations in these soils are relatively low, even for the high-traffic sites, as expected for a medium sized city.

  18. Uranium-lead systematics

    International Nuclear Information System (INIS)

    Wickman, F.E.

    1983-01-01

    The method of Levchenkov and Shukolyukov for calculating age and time disturbance of minerals without correction for original lead is generalized to include the cases when (1) original lead and radiogenic lead leach differently, and (2) the crystals studied consist of a core and a mantle. It is also shown that a straight line obtained from the solution of the equations is the locus of the isotopic composition of original lead. (Auth.)

  19. Lead dust in Broken Hill homes: effect of remediation on indoor lead levels.

    Science.gov (United States)

    Boreland, F; Lyle, D M

    2006-02-01

    This study was undertaken to determine whether home remediation effectively reduced indoor lead levels in Broken Hill, a long-established silver-lead-zinc mining town in outback Australia. A before-after study of the effect of home remediation on indoor lead levels was embedded into a randomized controlled trial of the effectiveness of remediation for reducing elevated blood lead levels in young children. Moist towelettes were used to measure lead loading (microg/m2) on internal windowsills and internal and entry floors of 98 homes; samples were collected before, immediately after, and 2, 4, 6, 8, and 10 months after remediation. Data were log(10) transformed for the analysis. Remediation reduced average indoor lead levels by approximately 50%, and lead levels remained low for the duration of the follow-up period (10 months). The greatest gains were made in homes with the highest initial lead levels; homes with low preremediation lead levels showed little or no benefit. Before remediation, homes located in areas with high soil lead levels or with "poor" dust proofing had higher lead levels than those in areas with lower soil lead levels or with "medium" or "good" dust proofing; these relative differences remained after remediation. There was no evidence that lead loading was reduced by an increased opportunity to become aware of lead issues. We conclude that remediation is an effective strategy for reducing the lead exposure of children living in homes with high indoor lead levels.

  20. High human exposure to lead through consumption of birds hunted with lead shot

    International Nuclear Information System (INIS)

    Johansen, P.; Asmund, G.; Riget, F.

    2004-01-01

    Lead shot contaminates the edible parts of birds so that tolerable human lead intake is exceeded. - We assess lead contamination of Greenland seabirds killed with lead shot having studied thick-billed murre and common eider, the two most important species in the diet. The lead concentration is very high in meat of eiders killed with lead shot (mean 6.1 μg/g-wet wt, 95% CL 2.1-12). This level is about 44 times higher than in drowned eiders and eight times higher than in shot murres. Analyzing whole breasts instead of sub-samples reveals about seven times higher lead levels in birds' meat. We conclude that in some cases the lead intake by Greenland bird eaters will largely exceed the FAO/WHO tolerable lead intake guideline and that lead shot is a more important source of lead in the diet than previously estimated

  1. Lead in the environment

    Science.gov (United States)

    Pattee, Oliver H.; Pain, Deborah J.; Hoffman, David J.; Rattner, Barnett A.; Burton, G. Allen; Cairns, John

    2003-01-01

    Anthropogenic uses of lead have probably altered its availability and environmental distribution more than any other toxic element. Consequently, lead concentrations in many living organisms may be approaching thresholds of toxicity for the adverse effects of lead. Such thresholds are difficult to define, as they vary with the chemical and physical form of lead, exposure regime, other elements present and also vary both within and between species. The technological capability to accurately quantify low lead concentrations has increased over the last decade, and physiological and behavioral effects have been measured in wildlife with tissue lead concentrations below those previously considered safe for humans.s.236 Consequently. lead criteria for the protection of wildlife and human health are frequently under review, and 'thresholds' of lead toxicity are being reconsidered. Proposed lead criteria for the protection of natural resources have been reviewed by Eisler. Uptake of lead by plants is limited by its generally low availability in soils and sediments, and toxicity may be limited by storage mechanisms and its apparently limited translocation within most plants. Lead does not generally accumulate within the foliar parts of plants, which limits its transfer to higher trophic levels. Although lead may concentrate in plant and animal tissues, no evidence of biomagnification exists. Acid deposition onto surface waters and soils with low buffering capacity may influence the availability of lead for uptake by plants and animals, and this may merit investigation at susceptible sites. The biological significance of chronic low-level lead exposure to wildlife is sometimes difficult to quantify. Animals living in urban environments or near point sources of lead emission are inevitably subject to greater exposure to lead and enhanced risk of lead poisoning. Increasingly strict controls on lead emissions in many countries have reduced exposure to lead from some sources

  2. Anemia risk in relation to lead exposure in lead-related manufacturing

    Directory of Open Access Journals (Sweden)

    Nan-Hung Hsieh

    2017-05-01

    Full Text Available Abstract Background Lead-exposed workers may suffer adverse health effects under the currently regulated blood lead (BPb levels. However, a probabilistic assessment about lead exposure-associated anemia risk is lacking. The goal of this study was to examine the association between lead exposure and anemia risk among factory workers in Taiwan. Methods We first collated BPb and indicators of hematopoietic function data via health examination records that included 533 male and 218 female lead-exposed workers between 2012 and 2014. We used benchmark dose (BMD modeling to estimate the critical effect doses for detection of abnormal indicators. A risk-based probabilistic model was used to characterize the potential hazard of lead poisoning for job-specific workers by hazard index (HI. We applied Bayesian decision analysis to determine whether BMD could be implicated as a suitable BPb standard. Results Our results indicated that HI for total lead-exposed workers was 0.78 (95% confidence interval: 0.50–1.26 with risk occurrence probability of 11.1%. The abnormal risk of anemia indicators for male and female workers could be reduced, respectively, by 67–77% and 86–95% by adopting the suggested BPb standards of 25 and 15 μg/dL. Conclusions We conclude that cumulative exposure to lead in the workplace was significantly associated with anemia risk. This study suggests that current BPb standard needs to be better understood for the application of lead-exposed population protection in different scenarios to provide a novel standard for health management. Low-level lead exposure risk is an occupational and public health problem that should be paid more attention.

  3. Synthesis of lithium niobate and monocrystal growth by Czochralski method

    International Nuclear Information System (INIS)

    Balzuweit, K.

    1988-01-01

    The qualitative analysis of lithium niobate by x-ray analysis and optical microscopy is presented. The lithium niobate compound was obtained by synthesis using niobium oxides and lithium carbonates. The lithium niobate monocrystal growth was done by Czochralski method. (M.C.K.)

  4. Lead exposure from lead pellets: age-related accumulation in mute swans

    Energy Technology Data Exchange (ETDEWEB)

    Eskildsen, J.; Grandjean, P.

    1984-05-01

    In a cross-sectional study of adult swans and their successfully fledged young in Ringkobing Fjord, West Jutland, Denmark, 128 venous blood samples were taken during the moulting period and analyzed for lead. While the juveniles generally showed blood lead levels below 15 micrograms/100 ml (median, 11 micrograms/100 ml), the values were significantly higher in adults (median, 25 micrograms/100 ml). Adult females showed slightly higher levels than did adult males. None of the birds examined showed signs of acute lead toxicity, and increased blood levels in adults may reflect increased lead body burdens from previous ingestion of lead shot as gizzard stones.

  5. A Novel GH-92 Nano-Adsorbent Using the Sponge from the Persian Gulf for Lead and Cadmium Removal

    Directory of Open Access Journals (Sweden)

    Hossein Ghafourian

    2015-05-01

    Full Text Available Removing pollutants from aquatic ecosystems, especially from drinking water, has always been a major concern for scientists. Recent decades have witnessed the widespread application of natural compounds used as adsorbents to remove various pollutants. On the other hand, studies have proved nanotechnology to be an effective way of removing pollutants. A new type of sponge belonging to the family Demospongiae that has nano holes and is native to the Persian Gulf was investigated for the first time in the present study for use as an adsorbent to remove calcium, magnesium, cobalt, cadmium, and lead ions from water. For this purpose, adbsorption in sponges of different aggregate sizes, contact time, particle size, and ambient pH were measured. The results showed that the proposed sponge is capable of adsorbing the above-mentioned metal ions to various degrees. While small amounts of calcium, magnesium, and cobalt were adsorbed by this sponge, cadmium recorded a higher adsorption of 2.37 mg/g at pH=5. The highest adsorption level of 79.19 mg per gram of adsorbent was recorded for lead at a pH range of 4.5-5 with a mesh size of 230. This is the highest adsorption ever recorded for lead in the literature on selective separation of lead from the other ions.

  6. Specificities of reactor coolant pumps units with lead and lead-bismuth coolant

    International Nuclear Information System (INIS)

    Beznosov, A.V.; Anotonenkov, M.A.; Bokov, P.A.; Baranova, V.S.; Kustov, M.S.

    2009-01-01

    The analysis results of impact of lead and lead-bismuth coolants specific properties on the coolants flow features in flow channels of the main and auxiliary circulating pumps are presented. Impossibility of cavitation initiation in flow channels of vane pumps pumping lead and lead-bismuth coolants was demonstrated. The experimental research results of discontinuity of heavy liquid metal coolant column were presented and conditions of gas cavitation initiation in coolant flow were discussed. Invalidity of traditional calculation methods of water and sodium coolants circulation pumps calculations for lead and lead-bismuth coolants circulation pumps was substantiated [ru

  7. Photocatalyzed removal of lead ion from lead-chelator solution

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Hyun; Na, Jung Won; Sung, Ki Woung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    The present study was undertaken to examine the influence of such chelating agents on the ease and speed of photocatalyzed metal removal and deposition. With excess EDTA, the free EDTA competes with Pb for oxidation, and at a ten fold excess, no lead oxidation (hence removal) occurs. With insufficient EDTA, the corresponding initial concentration of Pb-EDTA is decreased; after its destruction, the remaining Pb{sup 2+} is removed more slowly, at rates found with lead nitrate solution. The net result is that the maximum rate of lead deposition occurs at the stoichiometric ratio of 1:1 EDTA : Pb{sup 2+}.

  8. Vector boson and Charmonium production in proton-lead and lead-lead collisions with ATLAS at the LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00241320; The ATLAS collaboration

    2016-01-01

    Electroweak bosons do not interact strongly with the dense and hot medium formed in nuclear collisions, and thus should be sensitive to the nuclear modification of parton distribution functions (nPDFs). The in-medium modification of heavy charmonium states plays an important role in studying the hot and dense medium. The ATLAS detector, optimized to search for new physics in proton-proton collisions, is well equipped to measure Z and W bosons as well as quarkonium in the high occupancy environment produced in heavy ion collisions. Results from the ATLAS experiment on W and Z boson yields as a function of centrality, transverse momentum and rapidity, in lead-lead and proton-lead collisions are presented. Quarkonium results from proton-lead collisions are also presented.

  9. Influence of Lead on the Interpretation of Bone Samples with Laser-Induced Breakdown Spectroscopy

    Directory of Open Access Journals (Sweden)

    Abdolhamed Shahedi

    2016-01-01

    Full Text Available This study is devoted to tracing and identifying the elements available in bone sample using Laser-Induced Breakdown Spectroscopy (LIBS. The bone samples were prepared from the thigh of laboratory rats, which consumed 325.29 g/mol lead acetate having 4 mM concentration in specified time duration. About 76 atomic lines have been analyzed and we found that the dominant elements are Ca I, Ca II, Mg I, Mg II, Fe I, and Fe II. Temperature curve and bar graph were drawn to compare bone elements of group B which consumed lead with normal group, group A, in the same laboratory conditions. Plasma parameters including plasma temperature and electron density were determined by considering Local Thermodynamic Equilibrium (LTE condition in the plasma. An inverse relationship has been detected between lead absorption and elements like Calcium and Magnesium absorption comparing elemental values for both the groups.

  10. Lead-elevated activity of xanthine oxidase in lead-exposed workers

    Directory of Open Access Journals (Sweden)

    Sławomir Kasperczyk

    2013-04-01

    Full Text Available Background: The aim of the present study was to explore the connection between lead toxicity and the activity of xanthine oxidase (XO. In addition, we indicated the uric acid (UA and creatinine levels and concentration of erythrocyte malondialdehyde (MDA to estimate oxidative stress intensity. Materials and Methods: The examined group consisted of 125 healthy male employees of zinc and lead works. The examined group was divided into tertiles according to blood lead levels. In the collected blood samples, concentrations of lead-exposure indices, UA, creatinine, and MDA as well as activity of XO were measured concomitantly. The control group consisted of 32 healthy male administrative workers who were exposed to lead only environmentally. Results: XO activity and MDA level were significantly elevated in all tertiles compared to the control group. Creatinine level was significantly elevated in the medium and high tertiles. However, the level of UA was significantly elevated in the high tertile, while in the low and medium tertile only a tendency toward higher values was observed. Conclusions: Occupational exposure to lead induces activity of XO. This induction may contribute to the observed simultaneously increased oxidative stress, measured as MDA level, and the increased level of UA. Med Pr 2013;64(2:175–180

  11. Role of Airborne Lead in Increased Body Burden of Lead in Hartford Children*

    Science.gov (United States)

    Lepow, Martha L.; Bruckman, Leonard; Rubino, Robert A.; Markowitz, Steven; Gillette, Marybeth; Kapish, Janet

    1974-01-01

    The ingestion of airborne lead fallout is the mechanism responsible for increased lead body burdens found in 10 urban Connecticut children. The mean indoor lead levels found in housedust was 11,000 μg/g; highest concentrations occurred on windowsills and in floor dust. The mean lead content of Hartford street dirt was 1,200 μg/g; levels were highest near the street and next to the buildings. The mean lead concentration of hand samples taken from the subject children was 2,400 μg/g; the mean weight of hand samples was 11 mg. The concentration of lead in dirt and househould dust was high enough to theoretically result in excessive lead accumulation in young children who are putting their dusty, dirty hands in their mouths during play. While we believe that lead emitted from automobiles contributes significantly to air, dirt and dust lead levels the environmental impact of reducing or eliminating lead from gasoline is not yet completely understood. PMID:4133903

  12. Lead Poisoning Prevention Tips

    Science.gov (United States)

    ... or removed safely. How are children exposed to lead? Lead-based paint and lead contaminated dust are ... What can be done to prevent exposure to lead? It is important to determine the construction year ...

  13. The effects of thiamin on lead metabolism: organ distribution of lead 203.

    OpenAIRE

    Kim, J S; Hamilton, D L; Blakley, B R; Rousseaux, C G

    1992-01-01

    The effect of thiamin on the organ distribution of lead was evaluated in CD-1 mice exposed intragastrically or intraperitoneally to a single dose of lead acetate (100 micrograms) containing 100 microCi lead 203. They were treated with either thiamin (25 or 50 mg/kg body weight), calcium ethylenediaminetetraacetic acid (CaEDTA) (50 mg/kg body weight), or combinations of thiamin and CaEDTA. The whole body retention and the organ distribution of lead 203 varied depending upon the route of lead a...

  14. Method of handling of scrap lead from lead-acid batteries

    Energy Technology Data Exchange (ETDEWEB)

    Sytschev, A P; Kim, G V; Larin, V F; Sidorova, G D; Vicharev, I G; Kuur, V P; Achmetov, R S; Moiseev, G L; Maslov, V I; Kabatschek, V G

    1979-12-13

    Scrap lead and the casings of accumulators are mined and molten together in oxidixing atmosphere at a temperature of 1300 to 1500/sup 0/C. The lead oxide contained in the melt is then reduced to blue lead. Due to the combustion of the accumulator casings consisting of organic substances the fuel consumption in the melting process is reduced in accordance. The oxidizing atmosphere in the melting process is produced by use of air or oxygen.

  15. Lead isotope ratios in artists' lead white: a progress report

    Energy Technology Data Exchange (ETDEWEB)

    Keisch, B; Callahan, R C [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA)

    1976-07-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described.

  16. Activity of lead deposited in the tissues in conditions of occupational lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    The author measured urinary excretion of delta-aminolevulinic acid (ALA), coproporphyrins and lead, before and after administration of chelating agents (CaEDTA and D-penicillamine) to subjects presenting clinical symptoms of lead poisoning and workers occupationally exposed to lead. He found a great increase in lead following its mobilization in subjects with lead poisoning who had previously shown a high level of haemoglobin precursors and a low urinary lead level. In these subjects ALA excretion was proportional to the duration of exposure. A correlation was found between urinary ALA and coproporphyrins, on the one hand, and lead excretion after provocation, on the other. This suggests that the lead deposited in the tissues, as well as that in circulation, retains all its activity.

  17. Health care of people at work. Workers exposed to lead. I. Inorganic lead

    Energy Technology Data Exchange (ETDEWEB)

    Waldron, H.A.

    1978-01-01

    The risks associated with exposure to inorganic lead and the means by which these risks can be minimized are outlined. Lead is used to make a variety of metal products, the grids and oxides in storage batteries, pigments, chemicals, and also for lead plating. In the United States about 70% of the total lead consumption is related to transportation. Uptake of inorganic lead is by ingestion and inhalation. About 90% of the total body burden of lead is contained within the skeletal tissues. Lead is excreted in the kidney, in sweat, and in milk. Toxic effects are directed against the blood, the nervous system, and the kidney. Symptoms of lead poisoning are abdominal pain, constipation, vomiting, asthenia, paresthesia, psychological symptoms, and diarrhea. Physical and biological monitoring can serve to protect workers. Diagnosis of lead poisoning is not easy. Treatment involves removal from exposure and/or treatment with a chelating agent.

  18. Leading Democratically

    Science.gov (United States)

    Brookfield, Stephen

    2010-01-01

    Democracy is the most venerated of American ideas, the one for which wars are fought and people die. So most people would probably agree that leaders should be able to lead well in a democratic society. Yet, genuinely democratic leadership is a relative rarity. Leading democratically means viewing leadership as a function or process, rather than…

  19. Raman spectroscopy study of Na.sub.1/2./sub.Bi.sub.1/2./sub.TiO.sub.3./sub.-BaTiO.sub.3./sub. lead-free single crystal relaxor piezoelectrics

    Czech Academy of Sciences Publication Activity Database

    Gregora, Ivan; Ondrejkovič, Petr; Simon, Elizabeth; Berta, Milan; Savinov, Maxim; Hlinka, Jiří; Luo, H.; Zhang, Q.

    2010-01-01

    Roč. 404, č. 1 (2010), s. 220-2 ISSN 0015-0193 R&D Projects: GA AV ČR KAN301370701; GA ČR GA202/06/0411; GA ČR GD202/09/H041 Institutional research plan: CEZ:AV0Z10100520 Keywords : bismuth sodium niobate * lead-free titanates * relaxor * Raman spectra Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.511, year: 2010

  20. Nonlinear optical oscillation dynamics in high-Q lithium niobate microresonators.

    Science.gov (United States)

    Sun, Xuan; Liang, Hanxiao; Luo, Rui; Jiang, Wei C; Zhang, Xi-Cheng; Lin, Qiang

    2017-06-12

    Recent advance of lithium niobate microphotonic devices enables the exploration of intriguing nonlinear optical effects. We show complex nonlinear oscillation dynamics in high-Q lithium niobate microresonators that results from unique competition between the thermo-optic nonlinearity and the photorefractive effect, distinctive to other device systems and mechanisms ever reported. The observed phenomena are well described by our theory. This exploration helps understand the nonlinear optical behavior of high-Q lithium niobate microphotonic devices which would be crucial for future application of on-chip nonlinear lithium niobate photonics.

  1. Who Leads China's Leading Universities?

    Science.gov (United States)

    Huang, Futao

    2017-01-01

    This study attempts to identify the major characteristics of two different groups of institutional leaders in China's leading universities. The study begins with a review of relevant literature and theory. Then, there is a brief introduction to the selection of party secretaries, deputy secretaries, presidents and vice presidents in leading…

  2. Remediation of lead contaminated soil

    International Nuclear Information System (INIS)

    Urban, W.; Krishnamurthy, S.

    1992-01-01

    Lead contaminated soil in urban area is of major concern because of the potential health risk to children. Many studies have established a direct correlation between lead in soil and elevated blood lead levels in children. In Minneapolis, Minnesota, Mielke et al. (1983) reported that 50% of the Hmong children with lead poisioning were in areas where soil lead levels were between 500 and 1000 micrograms per gram (ug/g), and 40% of the children suffering from lead poisioning lived in areas where soil lead levels exceeded 1000 ug/g. In urban areas, lead pollution in soil has come from many different sources. The sources include lead paint, lead batteries and automobile exhaust. Olson and Skogerbee (1975) found the following lead compounds in soils where the primary source of pollution was from automobiles: lead sulfate, lead oxide, lead dioxide, lead sulfide, and metallic lead. The primary form of lead found was lead sulfate. Lead sulfate, lead tetraoxide, white lead, and other forms of lead have been used in the manufacture of paints for houses. At present, two remediation techniques, solidification and Bureau of Mines fluosilicic acid leaching, are available for lead-contaminated sites. The objective of the present investigation at the Risk Reduction Engineering Laboratory (RREL), Edison, was to try to solubilize the lead species by appropriate reagents and then recover the contaminants by precipitation as lead sulfate, using environmentally acceptable methods. The apparatus used for mixing was a LabMaster mixer, with variable speed and high-shear impeller. Previous work had used nitric acid for dissolving metallic lead. Owing to the environmental concerns, it was decided to use acetic acid in the presence of oxygen. The theoretical justification for this approach is the favorable redox potential for the reaction between metallic lead, acetic acid, and gaseous oxygen

  3. Lead theft--a study of the "uniqueness" of lead from church roofs.

    Science.gov (United States)

    Bond, John W; Hainsworth, Sarah V; Lau, Tien L

    2013-07-01

    In the United Kingdom, theft of lead is common, particularly from churches and other public buildings with lead roofs. To assess the potential to distinguish lead from different sources, 41 samples of lead from 24 church roofs in Northamptonshire, U.K, have been analyzed for relative abundance of trace elements and isotopes of lead using X-ray fluorescence (XRF) and inductively coupled plasma mass spectrometry, respectively. XRF revealed the overall presence of 12 trace elements with the four most abundant, calcium, phosphorus, silicon, and sulfur, showing a large weight percentage standard error of the mean of all samples suggesting variation in the weight percentage of these elements between different church roofs. Multiple samples from the same roofs, but different lead sheets, showed much lower weight percentage standard errors of the mean suggesting similar trace element concentrations. Lead isotope ratios were similar for all samples. Factors likely to affect the occurrence of these trace elements are discussed. © 2013 American Academy of Forensic Sciences.

  4. Lead isotope ratios in artists' lead white: a progress report

    International Nuclear Information System (INIS)

    Keisch, B.; Callahan, R.C.

    1976-01-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described. (author)

  5. Quantification of atmospheric lead emissions from 70 years of leaded petrol consumption in Australia

    Science.gov (United States)

    Kristensen, Louise Jane

    2015-06-01

    Lead is a persistent pollutant and the subject of many environmental studies, yet, in Australia, the extent of atmospheric lead emissions from the use of leaded petrol is unquantified. This paper details the first comprehensive account of leaded petrol sales and its lead concentrations over the 70 years of use in Australia. The resulting atmospheric lead emissions are calculated to provide the most complete understanding of the volume of lead released to the Australian continent from the consumption of leaded petrol. Atmospheric emissions of lead to the entire Australian continent from leaded petrol are calculated to total 240,510 tonnes over seven decades of use, peaking at 7869 tonnes in 1974. Total emissions for individual states and territories range from 1745 to 67,893 tonnes, with New South Wales responsible for the largest emissions. The effect of regulations on allowable concentrations of tetraethyl-lead additives are observed in the reduction of lead emissions in New South Wales and Victoria. The consequences to human health and the environment of leaded petrol consumption in Australia's populous cities are examined against historical air quality data and blood lead levels.

  6. Large-capacity current leads

    International Nuclear Information System (INIS)

    Ballarino, A.

    2008-01-01

    Feeding superconducting magnets with reliable low-loss devices is a key issue for any cryo-electrical system. Conventional or HTS current leads can be used, and cooling methods, materials, and geometries can be chosen to optimize the thermo-electrical performance of the system. The LHC magnets are powered via more than 3000 current leads transporting altogether about 3 MA of current. With thousands of leads, the LHC lead project represents today the largest project of its kind ever undertaken. Following a review of the LHC lead project, an overview of the choices that can be made for the optimization of large capacity current leads is presented. Examples are given of other leads for large scale magnet systems for which the use of HTS is being envisaged

  7. Performance of Lead-Free versus Lead-Based Hunting Ammunition in Ballistic Soap

    Science.gov (United States)

    Gremse, Felix; Krone, Oliver; Thamm, Mirko; Kiessling, Fabian; Tolba, René Hany; Rieger, Siegfried; Gremse, Carl

    2014-01-01

    Background Lead-free hunting bullets are an alternative to lead-containing bullets which cause health risks for humans and endangered scavenging raptors through lead ingestion. However, doubts concerning the effectiveness of lead-free hunting bullets hinder the wide-spread acceptance in the hunting and wildlife management community. Methods We performed terminal ballistic experiments under standardized conditions with ballistic soap as surrogate for game animal tissue to characterize dimensionally stable, partially fragmenting, and deforming lead-free bullets and one commonly used lead-containing bullet. The permanent cavities created in soap blocks are used as a measure for the potential wound damage. The soap blocks were imaged using computed tomography to assess the volume and shape of the cavity and the number of fragments. Shots were performed at different impact speeds, covering a realistic shooting range. Using 3D image segmentation, cavity volume, metal fragment count, deflection angle, and depth of maximum damage were determined. Shots were repeated to investigate the reproducibility of ballistic soap experiments. Results All bullets showed an increasing cavity volume with increasing deposited energy. The dimensionally stable and fragmenting lead-free bullets achieved a constant conversion ratio while the deforming copper and lead-containing bullets showed a ratio, which increases linearly with the total deposited energy. The lead-containing bullet created hundreds of fragments and significantly more fragments than the lead-free bullets. The deflection angle was significantly higher for the dimensionally stable bullet due to its tumbling behavior and was similarly low for the other bullets. The deforming bullets achieved higher reproducibility than the fragmenting and dimensionally stable bullets. Conclusion The deforming lead-free bullet closely resembled the deforming lead-containing bullet in terms of energy conversion, deflection angle, cavity shape

  8. Performance of lead-free versus lead-based hunting ammunition in ballistic soap.

    Directory of Open Access Journals (Sweden)

    Felix Gremse

    Full Text Available BACKGROUND: Lead-free hunting bullets are an alternative to lead-containing bullets which cause health risks for humans and endangered scavenging raptors through lead ingestion. However, doubts concerning the effectiveness of lead-free hunting bullets hinder the wide-spread acceptance in the hunting and wildlife management community. METHODS: We performed terminal ballistic experiments under standardized conditions with ballistic soap as surrogate for game animal tissue to characterize dimensionally stable, partially fragmenting, and deforming lead-free bullets and one commonly used lead-containing bullet. The permanent cavities created in soap blocks are used as a measure for the potential wound damage. The soap blocks were imaged using computed tomography to assess the volume and shape of the cavity and the number of fragments. Shots were performed at different impact speeds, covering a realistic shooting range. Using 3D image segmentation, cavity volume, metal fragment count, deflection angle, and depth of maximum damage were determined. Shots were repeated to investigate the reproducibility of ballistic soap experiments. RESULTS: All bullets showed an increasing cavity volume with increasing deposited energy. The dimensionally stable and fragmenting lead-free bullets achieved a constant conversion ratio while the deforming copper and lead-containing bullets showed a ratio, which increases linearly with the total deposited energy. The lead-containing bullet created hundreds of fragments and significantly more fragments than the lead-free bullets. The deflection angle was significantly higher for the dimensionally stable bullet due to its tumbling behavior and was similarly low for the other bullets. The deforming bullets achieved higher reproducibility than the fragmenting and dimensionally stable bullets. CONCLUSION: The deforming lead-free bullet closely resembled the deforming lead-containing bullet in terms of energy conversion

  9. Penetration of a magnetic field into superconducting lead and lead-indium alloys

    International Nuclear Information System (INIS)

    Egloff, C.; Raychaudhuri, A.K.; Rinderer, L.

    1983-01-01

    The temperature dependence of the magnetic field penetration depth of superconducting lead and lead-indium alloys has been studied over the temperature range between about 2 K and T/sub c/. Data are analyzed in terms of the microscopic theory. The difficulties of a unique analysis of the penetration data are pointed out and a strategy for the analysis is discussed. The penetration depth at T = 0K for pure lead is determined as 522 A. This value, though higher than the previously accepted value for lead, is nevertheless consistent with the strong coupling character of lead

  10. Lead inclusions in aluminium

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Andersen, H.H.; Grabaek, L.; Bohr, J.

    1990-01-01

    Ion implantation at room temperature of lead into aluminum leads to spontaneous phase separation and formation of lead precipitates growing topotactically with the matrix. Unlike the highly pressurized (∼ 1-5 GPa) solid inclusions formed after noble gas implantations, the pressure in the lead precipitates is found to be less than 0.12 GPa. Recently the authors have observed the result that the lead inclusions in aluminum exhibit both superheating and supercooling. In this paper they review and elaborate on these results. Small implantation-induced lead precipitates embedded in an aluminum matrix were studied by x-ray diffraction

  11. EP toxicity testing of lead to resolve disposition of radioactively contaminated lead

    International Nuclear Information System (INIS)

    Larsen, M.M.; Boehmer, A.M.

    1986-03-01

    The Department of Energy (DOE), in its efforts to comply with the requirements of the Resource Conservation and Recovery Act (RCRA) of 1976, is concerned with hazardous waste which is also radioactively contaminated. There are no existing facilities to treat or dispose of these wastes. One such waste is lead, which is extensively used in the nuclear industry as shielding. This paper reports the results of leach testing of lead (both solid lead samples and lead shot) to resolve questions as to whether or not radioactively contaminated waste lead must be treated as a hazardous waste. The results of these tests showed that: some samples passed the leach test. Results of development efforts performed to date to recycle lead and those planned for the future are included in this report

  12. Elution of lead from lead zirconate titanate ceramics to acid rain

    Science.gov (United States)

    Tsurumi, Takaaki; Takezawa, Shuhei; Hoshina, Takuya; Takeda, Hiroaki

    2017-10-01

    The amount of lead that eluted from lead zirconate titanate (PZT) ceramics to artificial acid rain was evaluated. Four kinds of PZT ceramics, namely, pure PZT at MPB composition, CuO-added PZT, PZT with 10 mol % substitution of Ba for Pb, and CuO-added PZT with 10 mol % substitution of Ba for Pb, were used as samples of the elution test. These PZT ceramics of 8 mm2 and 1.1-1.2 mm thickness were suspended in 300 ml of H2SO4 solution of pH 4.0. The concentration of lead eluted from PZT was in the range from 0.2 to 0.8 ppm. It was found that both liquid phase formation by the addition of CuO and the substitution of Ba for Pb were effective to reduce the amount of lead that eluted. By fitting the leaching out curve with a classical equation, a master curve assuming no sampling effect was obtained. The lead concentration evaluated from the amount of lead that eluted from a commercial PZT plate to H2SO4 solution of pH 5.3 was almost the same as the limit in city water. It is concluded that PZT is not harmful to health and the environment and the amount of lead that eluted from PZT can be controlled by modifying PZT composition.

  13. Long range correlations, leading particle spectrum and correlations with leading particles

    International Nuclear Information System (INIS)

    Ilgenfritz, E.M.

    1976-05-01

    The unitary cluster emission model by de Groot and Ruijgrok is discussed as an approach to understand the leading particle behaviour. Consequences of the model concerning co--rrelations between leading particles and produced particles in the central region are considered. No satisfactory agreement was found. Production of leading clusters is argued for being an essential feature of these correlations. (author)

  14. Comparative toxicity of tetra ethyl lead and lead oxide to earthworms, Eisenia fetida (Savigny)

    International Nuclear Information System (INIS)

    Venkateswara Rao, J.; Kavitha, P.; Padmanabha Rao, A.

    2003-01-01

    Leaded gasoline contains tetra ethyl lead (TEL) as an antiknocking agent, which produces major amounts of lead oxide in automobile exhaust along with traces of TEL. To minimize the lead contamination, methyl tertiary butyl ether (MTBE) is used as a substitute for producing unleaded gasoline. It has become increasingly apparent that young children are highly susceptible to the harmful effects of lead. Hence, a study was carried out to monitor lead toxicity in soil, using adult earthworms (Eisenia fetida, Savigny). Leaded gasoline (TEL) and lead oxide are 383- and 211-fold more toxic than unleaded gasoline (MTBE) in 7 days of exposure and 627- and 290-fold more toxic in 14 days, respectively. Results indicate that the presence of TEL in leaded gasoline and lead oxide has a significant effect on behavior, morphology, and histopathology of earthworms. Absorption of TEL into the tissues is comparatively less than that of lead oxide but toxic effects were severe. Rupture of the cuticle, extrusion of coelomic fluid and inflexible metameric segmentation were observed, causing desensitization of the posterior region leading to fragmentation in earthworms

  15. Lead-resistant Providencia alcalifaciens strain 2EA bioprecipitates Pb+2 as lead phosphate.

    Science.gov (United States)

    Naik, M M; Khanolkar, D; Dubey, S K

    2013-02-01

    A lead-resistant bacteria isolated from soil contaminated with car battery waste were identified as Providencia alcalifaciens based on biochemical characteristics, FAME profile and 16S rRNA sequencing and designated as strain 2EA. It resists lead nitrate up to 0·0014 mol l(-1) by precipitating soluble lead as insoluble light brown solid. Scanning electron microscopy coupled with energy-dispersive X-ray spectrometric analysis (SEM-EDX) and X-ray diffraction spectroscopy (XRD) revealed extracellular light brown precipitate as lead orthophosphate mineral, that is, Pb(9) (PO(4))(6) catalysed by phosphatase enzyme. This lead-resistant bacterial strain also demonstrated tolerance to high levels of cadmium and mercury along with multiple antibiotic resistance. Providencia alcalifaciens strain 2EA could be used for bioremediation of lead-contaminated environmental sites, as it can efficiently precipitate lead as lead phosphate. © 2012 The Society for Applied Microbiology.

  16. Lead isotopes in soils near five historic American lead smelters and refineries

    International Nuclear Information System (INIS)

    Rabinowitz, Michael B.

    2005-01-01

    This survey of soil lead in the vicinity of old industrial sites examines how the stable isotope patterns vary among the sites according to the sources of the lead ore processed at each site. Lead smelters and refineries, which closed down decades ago, are the basis of this investigation. Samples were taken from near five old factory sites in Collinsville and Alton (Illinois), Ponderay (Idaho), East Chicago (Indiana) and Omaha (Nebraska). Historical records were searched for accounts of the sources of the lead. Lead concentrations were measured by atomic absorption flame spectrophotometry, and stable isotopic analysis was done by plasma ionization mass spectrometry. At every site visited, remnants of the old factories, in terms of soil lead pollution, could be found. In spite of potential complications of varying smelter feedstock sourced from mines of different geological age, it was possible to match the isotopic patterns in the soils with the documented sources of the ores. The Collinsville and Alton sites resembled Missouri lead. The Ponderay value was higher than major Bunker Hill, Idaho deposits, but closer to the minor, nearby Oreille County, Washington ores. Mostly Utah ore was used in East Chicago. The Omaha soil reflects lead from Mexico, Colorado and Montana

  17. The void nucleation mechanism within lead phase during spallation of leaded brass

    Science.gov (United States)

    Yang, Yang; Wang, Can; Chen, Xingzhi; Chen, Kaiguo; Hu, Haibo; Fu, Yanan

    2018-07-01

    The incipient spall behaviours of Cu-34%Zn-3%Pb leaded brass samples with annealed and cryogenic-treated conditions were loaded using one-stage light gas gun experiments. The effect of Pb-phase on dynamic damage nucleation in leaded brass specimens was investigated by means of optical microscopy, scanning electron microscopy and x-ray computer tomography. It was found that the voids of incipient spall were mainly nucleated in the interior of the lead (no tensile stress would be produced within lead according to the impact theory) instead of nucleated at the phase interface as expected by quasi-static damage fracture theory. A nucleation model is proposed in the present work that is the asymmetry high compression zones in the centre of the lead-phase were formed by the rarefaction wave convergence effects of matrix/quasi-spherical lead interface, which caused adiabatic temperature rise that exceeded melting point of lead due to severe plastic deformation, finally led to local melting and void nucleation. In addition, the spall strength and damage rate increased with the increase in the Pb-phase number.

  18. Lead toxicity on hematological parameters in workers with occupational exposure to lead

    International Nuclear Information System (INIS)

    Dursun, N.; Koese, K.

    1998-01-01

    The effects of lead on hematological parameters were studied in lead exposed male workers occupied for 17.84+-4.22 years in a metal powder producing factory in Kayseri, Turkey and control male workers in same city. Blood lead and plasma zinc levels were measured by Atomic Absorption Spectrophotometry (AAS) and hematological parameters by Culture Counter S. The lead exposure workers had higher lead levels (13.81+- 9.21 mug/dl) as compared to control subjects (2.37+-0.10 mug/dl). No difference was observed in the plasma zinc levels of both groups. As indices of lead exposure, red blood cell (RBC) counts, hemoglobin (Hb), and hematocrit (Hct) values significantly decreased. Mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular haemoglobin concentration (MCHC) significantly increased except MCV. There was also an increase in MCV, but it was not significant. (author)

  19. Monetary benefits of preventing childhood lead poisoning with lead-safe window replacement

    OpenAIRE

    Nevin, Rick; Jacobs, David / E.; Berg, Michael; Cohen, Jonathan

    2007-01-01

    Previous estimates of childhood lead poisoning prevention benefits have quantified the present value of some health benefits, but not the costs of lead paint hazard control or the benefits associated with housing and energy markets. Because older housing with lead paint constitutes the main exposure source today in the U.S., we quantify health benefits, costs, market value benefits, energy savings, and net economic benefits of lead-safe window replacement (which includes paint stabilization ...

  20. Pacemaker lead fracture without an increase in lead impedance caused by cardiac fibroma

    Directory of Open Access Journals (Sweden)

    Daisuke Sato

    2013-12-01

    Full Text Available We report the case of a 64-year-old man who had a permanent pacemaker with a unipolar silicone electrode positioned in the right ventricle in 1989 for sinus node dysfunction. On a routine checkup in June 2011, a 28-mm-diameter mass was discovered, which appeared to adhere to the tricuspid valve and the ventricular lead. The size of the mass did not change for the next 6 months, and the lead impedance was maintained at around 500–600 Ω. Because pacing failure was observed in January 2012, he underwent an urgent pacemaker check; however, the lead impedance was found not to have increased greatly (689 Ω. Nevertheless, the pacemaker lead was noted to be fractured at the tricuspid level. His echocardiogram showed new severe tricuspid regurgitation and a floating mass around the lead. We extracted the fractured lead, enucleated the tumor, replaced the tricuspid valve, and placed an epicardial lead. Macroscopic examination revealed that the tumor surrounded the fractured lead and covered the stump. Pathological examination revealed that the tumor was composed of fibrous connective tissue. We presumed that electric current continued to flow through the stump of the fractured unipolar lead to the generator, and this might have caused the limited increase in lead impedance.

  1. Regular Breakfast and Blood Lead Levels among Preschool Children

    Directory of Open Access Journals (Sweden)

    Needleman Herbert

    2011-04-01

    Full Text Available Abstract Background Previous studies have shown that fasting increases lead absorption in the gastrointestinal tract of adults. Regular meals/snacks are recommended as a nutritional intervention for lead poisoning in children, but epidemiological evidence of links between fasting and blood lead levels (B-Pb is rare. The purpose of this study was to examine the association between eating a regular breakfast and B-Pb among children using data from the China Jintan Child Cohort Study. Methods Parents completed a questionnaire regarding children's breakfast-eating habit (regular or not, demographics, and food frequency. Whole blood samples were collected from 1,344 children for the measurements of B-Pb and micronutrients (iron, copper, zinc, calcium, and magnesium. B-Pb and other measures were compared between children with and without regular breakfast. Linear regression modeling was used to evaluate the association between regular breakfast and log-transformed B-Pb. The association between regular breakfast and risk of lead poisoning (B-Pb≥10 μg/dL was examined using logistic regression modeling. Results Median B-Pb among children who ate breakfast regularly and those who did not eat breakfast regularly were 6.1 μg/dL and 7.2 μg/dL, respectively. Eating breakfast was also associated with greater zinc blood levels. Adjusting for other relevant factors, the linear regression model revealed that eating breakfast regularly was significantly associated with lower B-Pb (beta = -0.10 units of log-transformed B-Pb compared with children who did not eat breakfast regularly, p = 0.02. Conclusion The present study provides some initial human data supporting the notion that eating a regular breakfast might reduce B-Pb in young children. To our knowledge, this is the first human study exploring the association between breakfast frequency and B-Pb in young children.

  2. Highly reversible lead-carbon battery anode with lead grafting on the carbon surface

    KAUST Repository

    Yin, Jian; Lin, Nan; Zhang, Wenli; Lin, Zheqi; Zhang, Ziqing; Wang, Yue; Shi, Jun; Bao, Jinpeng; Lin, Haibo

    2018-01-01

    A novel C/Pb composite has been successfully prepared by electroless plating to reduce the hydrogen evolution and achieve the high reversibility of the anode of lead-carbon battery (LCB). The deposited lead on the surface of C/Pb composite was found to be uniform and adherent to carbon surface. Because lead has been stuck on the surface of C/Pb composite, the embedded structure suppresses the hydrogen evolution of lead-carbon anode and strengthens the connection between carbon additive and sponge lead. Compared with the blank anode, the lead-carbon anode with C/Pb composite displays excellent charge–discharge reversibility, which is attributed to the good connection between carbon additives and lead that has been stuck on the surface of C/Pb composite during the preparation process. The addition of C/Pb composite maintains a solid anode structure with high specific surface area and power volume, and thereby, it plays a significant role in the highly reversible lead-carbon anode.

  3. Highly reversible lead-carbon battery anode with lead grafting on the carbon surface

    KAUST Repository

    Yin, Jian

    2018-03-27

    A novel C/Pb composite has been successfully prepared by electroless plating to reduce the hydrogen evolution and achieve the high reversibility of the anode of lead-carbon battery (LCB). The deposited lead on the surface of C/Pb composite was found to be uniform and adherent to carbon surface. Because lead has been stuck on the surface of C/Pb composite, the embedded structure suppresses the hydrogen evolution of lead-carbon anode and strengthens the connection between carbon additive and sponge lead. Compared with the blank anode, the lead-carbon anode with C/Pb composite displays excellent charge–discharge reversibility, which is attributed to the good connection between carbon additives and lead that has been stuck on the surface of C/Pb composite during the preparation process. The addition of C/Pb composite maintains a solid anode structure with high specific surface area and power volume, and thereby, it plays a significant role in the highly reversible lead-carbon anode.

  4. Impact of lead tolerant plant growth promoting rhizobacteria on growth, physiology, antioxidant activities, yield and lead content in sunflower in lead contaminated soil.

    Science.gov (United States)

    Saleem, Muhammad; Asghar, Hafiz Naeem; Zahir, Zahir Ahmad; Shahid, Muhammad

    2018-03-01

    Present study was conducted to evaluate the effect of lead tolerant plant growth promoting rhizobacteria (LTPGPR) on growth, physiology, yield, antioxidant activities and lead uptake in sunflower in soil contaminated with lead under pot conditions. Three pre-characterized LTPGP strains (S2 (Pseudomonas gessardii strain BLP141), S5 (Pseudomonas fluorescens A506) and S10 (Pseudomonas fluorescens strain LMG 2189)) were used to inoculate sunflower growing in soil contaminated with different levels (300, 600 and 900 mg kg -1 ) of lead by using lead nitrate salt as source of lead. Treatments were arranged according to completely randomized design with factorial arrangements. At harvesting, data regarding growth attributes (root shoot length, root shoot fresh and dry weights), yield per plant, physiological attributes (Chlorophyll 'a', 'b' and carotenoids content), antioxidant activities (Ascorbate peroxidase, catalase, superoxide dismutase and glutathione reductase), proline and malanodialdehyde content, and lead content in root, shoot and achenes of sunflower were recorded. Data were analysed by standard statistical procedures. Results showed that lead contamination reduced the plants growth, physiology and yield at all levels of lead stress. But application of LTPGPR in soil contaminated with lead improved plant growth, physiology, yield, and antioxidant activities, proline, and reduced the malanodialdehyde content (that is reduced by the application of different strains in lead contamination) of sunflower as compared to plants grown in soil without inoculation. Inoculation also promoted the uptake of lead in root, shoots and reduced the uptake of lead in achenes of plants as compared to plants in lead contamination without inoculation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Effect of Ion Irradiation in Cadmium Niobate Pyrochlores

    International Nuclear Information System (INIS)

    Jiang, Weilin; Weber, William J.; Thevuthasan, Suntharampillai; Boatner, Lynn A.

    2003-01-01

    Irradiation experiments have been performed for cadmium niobate pyrochlore (CdNb2O) single crystals at both 150 and 300 K using 1.0 MeV Au ions over fluences ranging from 0.01 to 0.10 ions/nm. In-situ 3.0 MeV He Rutherford backscattering spectrometry along the -axial channeling direction (RBS/C) has been applied to study the damage states ranging from small defect concentrations to a fully amorphous state. Results show that the crystal can be readily amorphized under the irradiation conditions. Room-temperature recovery of the defects produced at 150 K has been observed, while the defects produced at 300 K are thermally stable at room temperature. Results also indicate that the RBS/C analysis used in this study induced negligible damage in the near-surface regime. In addition, irradiation at and below room temperature using He and C3 ions leads to surface exfoliation at the corresponding damage peaks

  6. Temporal stability of blood lead concentrations in adults exposed only to environmental lead

    Energy Technology Data Exchange (ETDEWEB)

    Delves, H T; Sherlock, J C; Quinn, M J

    1984-08-01

    The temporal stability of blood lead concentrations of 21 health adults (14 men and 7 women) exposed only to environmental lead was assessed by analysis of 253 blood specimens collected serially over periods from 7 to 11 months. The women had lower blood lead concentrations (mean 8.5, range 7.4-10.8 micrograms/100 ml) than did the men (mean 12.2, range 8.6-15.8 micrograms/100 ml). These are within the expected ranges for non-occupationally exposed persons. Blood lead concentrations in the serial specimens from both men and women changed very little over the study period, with standard deviations of less than 0.5 micrograms/100 ml for the majority of individual mean concentrations: for all except low subjects the standard deviations were less than 0.8 micrograms/100 ml. Two subjects showed significant changes in blood lead concentrations during the study. A temporary increase in oral lead intake was identified for one of these subjects. In the absence of substantial changes in lead exposure blood lead levels in adults are remarkably stable and for their environmental monitoring a single blood lead concentration is an excellent biological indicator.

  7. Correlations in particle production in proton-lead and lead-lead collisions at the LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00361447

    In high-energy heavy-ion collisions at the Large Hadron Collider (LHC), a hot and dense state of matter called the Quark-Gluon Plasma (QGP) is formed. The initial collision geometry and the subsequent expansion during the QGP stage result in the correlations of produced particles, through which the properties of the QGP can be investigated. Two analyses based on the geometrical correlations of produced particles, one in proton-lead (p–Pb) collisions and the other in lead-lead (Pb–Pb) collisions, are presented in this thesis. The data analyzed in this thesis were collected with the ALICE detector at the LHC in p– Pb collisions at a nucleon–nucleon center-of-mass energy of 5.02 TeV, and Pb–Pb collisions at a nucleon–nucleon center-of-mass energy of 2.76 TeV. In the forward-central two-particle correlation analysis in p–Pb collisions, two-particle an- gular correlations between trigger particles in the forward pseudorapidity range (2.5 < |η| < 4.0) and associated particles in the central ran...

  8. Levels and source apportionment of children's lead exposure: could urinary lead be used to identify the levels and sources of children's lead pollution?

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-04-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as (207)Pb/(206)Pb, (208)Pb/(206)Pb and (204)Pb/(206)Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Determining tissue-lead levels in large game mammals harvested with lead bullets: human health concerns.

    Science.gov (United States)

    Tsuji, L J S; Wainman, B C; Jayasinghe, R K; VanSpronsen, E P; Liberda, E N

    2009-04-01

    Recently, the use of lead isotope ratios has definitively identified lead ammunition as a source of lead exposure for First Nations people, but the isotope ratios for lead pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden; however, few studies have determined if lead bullet fragments are present in big game carcasses. We found elevated tissue-lead concentrations (up to 5,726.0 microg/g ww) in liver (5/9) and muscle (6/7) samples of big game harvested with lead bullets and radiographic evidence of lead fragments. Thus, we would advise that the tissue surrounding the wound channel be removed and discarded, as this tissue may be contaminated by lead bullet fragments.

  10. Lead intoxication in dogs: risk assessment of feeding dogs trimmings of lead-shot game.

    Science.gov (United States)

    Høgåsen, Helga R; Ørnsrud, Robin; Knutsen, Helle K; Bernhoft, Aksel

    2016-07-25

    Expanding lead-based bullets, commonly used for hunting of big game, produce a scattering of lead particles in the carcass around the wound channel. Trimmings around this channel, which are sometimes fed to dogs, may contain lead particles. The aim of this study was to assess potential health effects of feeding dogs such trimmings. Lead ingestion most commonly causes gastrointestinal and neurological clinical signs, although renal, skeletal, haematological, cardiovascular and biochemical effects have also been reported. Experimental data indicate that a daily dose of around 1 mg lead as lead acetate/kg body weight for ten days may be considered as a Lowest Observed Effect Level in dogs. Acute toxicity documentation from the Centers for Disease Control and Prevention indicates 300 mg/kg body weight as the lowest dose of lead acetate causing death in dogs after oral ingestion. Our assessment suggests that dogs fed trimmings of lead-shot game may be affected by the amounts of lead present, and that even deadly exposure could occasionally occur. The intestinal absorption of lead from bullets was assumed to be 10-80 % of that of lead acetate, reflecting both the variability in particle size and uncertainty about the bioavailability of metallic lead in dogs. Despite data gaps, this study indicates that feeding dogs trimmings of lead-shot game may represent a risk of lead intoxication. More research is needed to assess the exact consequences, if lead-based bullets are still to be used. Meanwhile, we recommend that trimmings close to the wound channel should be made inaccessible to dogs, as well as to other domestic or wild animals.

  11. NA49: lead-lead collision

    CERN Multimedia

    1996-01-01

    This is an image of an actual lead ion collision taken from tracking detectors on the NA49 experiment, part of the heavy ion project at CERN. These collisions produce a very complicated array of hadrons as the heavy ions break up. It is hoped that one of these collisions will eventually create a new state of matter known as quark-gluon plasma.

  12. Eryptosis in lead-exposed workers

    International Nuclear Information System (INIS)

    Aguilar-Dorado, Itzel-Citlalli; Hernández, Gerardo; Quintanar-Escorza, Martha-Angelica; Maldonado-Vega, María; Rosas-Flores, Margarita; Calderón-Salinas, José-Víctor

    2014-01-01

    Eryptosis is a physiological phenomenon in which old and damaged erythrocytes are removed from circulation. Erythrocytes incubated with lead have exhibited major eryptosis. In the present work we found evidence of high levels of eryptosis in lead exposed workers possibly via oxidation. Blood samples were taken from 40 male workers exposed to lead (mean blood lead concentration 64.8 μg/dl) and non-exposed workers (4.2 μg/dl). The exposure to lead produced an intoxication characterized by 88.3% less δ-aminolevulinic acid dehydratase (δALAD) activity in lead exposed workers with respect to non-lead exposed workers. An increment of oxidation in lead exposed workers was characterized by 2.4 times higher thiobarbituric acid-reactive substance (TBARS) concentration and 32.8% lower reduced/oxidized glutathione (GSH/GSSG) ratio. Oxidative stress in erythrocytes of lead exposed workers is expressed in 192% higher free calcium concentration [Ca 2+ ] i and 1.6 times higher μ-calpain activity with respect to non-lead exposed workers. The adenosine triphosphate (ATP) concentration was not significantly different between the two worker groups. No externalization of phosphatidylserine (PS) was found in non-lead exposed workers (< 0.1%), but lead exposed workers showed 2.82% externalization. Lead intoxication induces eryptosis possibly through a molecular pathway that includes oxidation, depletion of reduced glutathione (GSH), increment of [Ca 2+ ], μ-calpain activation and externalization of PS in erythrocytes. Identifying molecular signals that induce eryptosis in lead intoxication is necessary to understand its physiopathology and chronic complications. - Graphical abstract: Fig. 1. (A) Blood lead concentration (PbB) and (B) phosphatidylserine externalization on erythrocyte membranes of non-lead exposed (□) and lead exposed workers (■). Values are mean ± SD. *Significantly different (P < 0.001). - Highlights: • Erythrocytes of lead exposed workers showed higher PS

  13. Eryptosis in lead-exposed workers

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Dorado, Itzel-Citlalli [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Hernández, Gerardo [Section of Methodology of Science, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Quintanar-Escorza, Martha-Angelica [Faculty of Medicine, UJED, Durango, DGO (Mexico); Maldonado-Vega, María [CIATEC, León, GTO (Mexico); Rosas-Flores, Margarita [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Calderón-Salinas, José-Víctor, E-mail: jcalder@cinvestav.mx [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico)

    2014-12-01

    Eryptosis is a physiological phenomenon in which old and damaged erythrocytes are removed from circulation. Erythrocytes incubated with lead have exhibited major eryptosis. In the present work we found evidence of high levels of eryptosis in lead exposed workers possibly via oxidation. Blood samples were taken from 40 male workers exposed to lead (mean blood lead concentration 64.8 μg/dl) and non-exposed workers (4.2 μg/dl). The exposure to lead produced an intoxication characterized by 88.3% less δ-aminolevulinic acid dehydratase (δALAD) activity in lead exposed workers with respect to non-lead exposed workers. An increment of oxidation in lead exposed workers was characterized by 2.4 times higher thiobarbituric acid-reactive substance (TBARS) concentration and 32.8% lower reduced/oxidized glutathione (GSH/GSSG) ratio. Oxidative stress in erythrocytes of lead exposed workers is expressed in 192% higher free calcium concentration [Ca{sup 2+}]{sub i} and 1.6 times higher μ-calpain activity with respect to non-lead exposed workers. The adenosine triphosphate (ATP) concentration was not significantly different between the two worker groups. No externalization of phosphatidylserine (PS) was found in non-lead exposed workers (< 0.1%), but lead exposed workers showed 2.82% externalization. Lead intoxication induces eryptosis possibly through a molecular pathway that includes oxidation, depletion of reduced glutathione (GSH), increment of [Ca{sup 2+}], μ-calpain activation and externalization of PS in erythrocytes. Identifying molecular signals that induce eryptosis in lead intoxication is necessary to understand its physiopathology and chronic complications. - Graphical abstract: Fig. 1. (A) Blood lead concentration (PbB) and (B) phosphatidylserine externalization on erythrocyte membranes of non-lead exposed (□) and lead exposed workers (■). Values are mean ± SD. *Significantly different (P < 0.001). - Highlights: • Erythrocytes of lead exposed workers

  14. Micromachining Lithium Niobate for Rapid Prototyping of Resonant Biosensors

    International Nuclear Information System (INIS)

    Al-Shibaany, Zeyad Yousif Abdoon; Hedley, John; Huo, Dehong; Hu, Zhongxu

    2014-01-01

    Lithium niobate material is widely used in MEMS application due to its piezoelectric properties. This paper presents the micromachining process of lithium niobate to rapid prototype a resonant biosensor design. A high precision CNC machine was used to machine a sample of lithium niobate material at 5 different spindle speeds to find out the best conditions to machine this brittle material. A qualitative visual check of the surface was performed by using scanning electron microscopy, surface roughness was quantitatively investigated using an optical surface profiler and Raman spectroscopy to check the strain of the surface. Results show that the surface quality of the lithium niobate was significantly affected by the spindle speed with optimum conditions at 70k rpm giving a strained surface with 500 nm rms roughness

  15. Lead Leached into Water from Select Plumbing Fixtures” Could Lead to Health Hazard

    Directory of Open Access Journals (Sweden)

    Ramsey Coles

    2014-01-01

    Full Text Available Background: Lead is an inert metal and is resistant to corrosion. It also increases tensile strength of many common materials in daily use. Lead was used during the Roman period to transport water (hence the name plumbing/plumber is common terminology even in the present day. Lead enters the biological system through the air, water, and dust. Fine particles of lead, having diameter less than 5 nm are directly absorbed by lungs. Inorganic lead is absorbed by the gastrointestinal tract, and organic lead is absorbed by the skin. Lead has long been known to be a toxic heavy metal and exposure is associated with many deleterious health effects. Still, lead remains a popular ingredient in products ranging from paint to batteries. The lead content in any given material is estimated using various methods. The least cumbersome method is found to be X-Ray Fluorescence technique (XRF. A portable XRF device was used in the present study. Aim: The main aim of this study to investigate whether lead is present in various commonly used plumbing materials. Material and Methods: All types of branded and commonly used pipes were gathered from a market in Bangalore and tested using the XRF machine. In order to evaluate to what extent lead from the pipes could leach into water, seven pipes were randomly selected and filled with Aquafina water (having undetectable level of lead for a 24 hour period. This water was tested at an NABL accredited laboratory in Bangalore, India for lead content. Result: It was determined that lead was present in many of the samples, at an unacceptable levels ranging from, well above the globally accepted level of 0.01 mg/L proof that lead was able to leach from the samples into water. Conclusions: As lead in drinking water represents a direct pathway for human exposure, the authors recommend that significant measures be taken to prevent use of lead in the plumbing industry for prevention of it’s deleterious effects. Authors have also

  16. Lead Poison Detection

    Science.gov (United States)

    1976-01-01

    With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

  17. Lead remediation and changes in human lead exposure: some physiological and biokinetic dimensions.

    Science.gov (United States)

    Mushak, Paul

    2003-02-15

    This paper presents a qualitative and quantitative analysis of the various aspects of lead remediation effectiveness with particular reference to human health risk assessment. One of the key elements of lead remediation efforts at such sites as those under the Superfund program deals with populations at elevated exposure and toxicity risk in the proximity of, or at, the site of remediation, especially remediation workers, workers at other tasks on sites that were remediated down to some action level of lead concentration in soils, and groups at risk in nearby communities. A second element has to do with how one measures or models lead exposure changes with special reference to baseline and post-remediation conditions. Various biomarkers of lead exposure can be employed, but their use requires detailed knowledge of what results using each means. The most commonly used approach is measurement of blood lead (Pb-B). Recognized limitations in the use of Pb-B has led to the use of predictive Pb exposure models, which are less vulnerable to the many behavioral, physiological, and environmental parameters that can distort isolated or 'single shot' Pb-B testings. A third aspect covered in this paper presents various physiological factors that affect the methods by which one evaluates Pb remediation effectiveness. Finally, this article offers an integrated look at how lead remediation actions directed at one lead source or pathway affect the total lead exposure picture for human populations at elevated lead exposure and toxicity risk.

  18. Superconductivity in nanostructured lead

    Science.gov (United States)

    Lungu, Anca; Bleiweiss, Michael; Amirzadeh, Jafar; Saygi, Salih; Dimofte, Andreea; Yin, Ming; Iqbal, Zafar; Datta, Timir

    2001-01-01

    Three-dimensional nanoscale structures of lead were fabricated by electrodeposition of pure lead into artificial porous opal. The size of the metallic regions was comparable to the superconducting coherence length of bulk lead. Tc as high as 7.36 K was observed, also d Tc/d H was 2.7 times smaller than in bulk lead. Many of the characteristics of these differ from bulk lead, a type I superconductor. Irreversibility line and magnetic relaxation rates ( S) were also studied. S( T) displayed two maxima, with a peak value about 10 times smaller than that of typical high- Tc superconductors.

  19. Lead (Pb) Air Pollution

    Science.gov (United States)

    ... Regional Offices Labs and Research Centers Lead (Pb) Air Pollution Contact Us Share As a result of EPA's ... and protect aquatic and terrestrial ecosystems. Lead (Pb) Air Pollution Basic Information How does lead get in the ...

  20. Lead poisoning: The invisible disease

    Science.gov (United States)

    Friend, Milton

    1989-01-01

    Lead poisoning is an intoxication resulting from absorption of hazardous levels of lead into body tissues. Lead pellets from shot shells, when ingested, are the most common source of lead poisoning in migratory birds. Other far less common sources include lead fishing sinkers, mine wastes, paint pigments, bullets, and other lead objects that are swallowed.

  1. Taking the Lead : Gender, Social Context and Preference to Lead

    NARCIS (Netherlands)

    Hong, A.P.C.I.; Schaafsma, J.; van der Wijst, P.J.

    2014-01-01

    Previous research has demonstrated that women tend to emerge as leaders less often than men. In the present study, we examined to what extent women's and men's preference to lead is influenced by social context. It was hypothesized that women have a less strong preference to lead than men in a

  2. Biological fractionation of lead isotopes in Sprague-Dawley rats lead poisoned via the respiratory tract.

    Directory of Open Access Journals (Sweden)

    Jing Wu

    Full Text Available It was considered that lead isotope ratios did not change during physical, chemical, or biological processes. Thus, lead isotope ratios have been used as fingerprints to identify possible lead sources. However, recent evidence has shown that the lead isotope ratios among different biological samples in human are not always identical from its lead origins in vitro. An animal experiment was conducted to explore the biological fractionation of lead isotopes in biological systems.24 male Sprague-Dawley (SD rats were divided into groups that received acute lead exposure (0, 0.02, 0.2, or 2 mg/kg body weight of lead acetate via the respiratory route every day for 5 days. Biological samples (i.e., blood, urine, and feces were collected for comparison with the lead acetate (test substance and the low-lead animal feed (diet administered to the rats. The lead isotope ratios were determined by inductively coupled plasma mass spectrometry (ICP-MS.There are significant differences (p<0.05 in lead isotope ratios between blood, urine, and feces. Moreover, a nonlinear relationship between the blood lead concentration and the blood lead isotope ratios was observed. There is also a threshold effect to the fractionation function. Only the blood isotope ratio of (204Pb/(206Pb matches the test substance well. As for feces, when (204Pb/(206Pb ratio is considered, there is no significant difference between feces-test substance pairs in medium and high dose group.The biological fractionation of lead isotopes in SD rats was observed. Moreover, there might be a threshold for the biological fractionation of lead isotopes which is depending on whole blood lead level. It is considered to be more reliable that we compared the isotope ratios of potential lead hazards with both blood and feces lead fingerprints especially for (204Pb/(206Pb ratio under high-dose exposure.

  3. Catalytic oxidation of soot over alkaline niobates

    International Nuclear Information System (INIS)

    Pecchi, G.; Cabrera, B.; Buljan, A.; Delgado, E.J.; Gordon, A.L.; Jimenez, R.

    2013-01-01

    Highlights: ► No previous reported studies about alkaline niobates as catalysts for soot oxidation. ► NaNbO 3 and KNbO 3 perovskite-type oxides show lower activation energy than other lanthanoid perovskite-type oxides. ► The alkaline niobate does not show deactivation by metal loss. - Abstract: The lack of studies in the current literature about the assessment of alkaline niobates as catalysts for soot oxidation has motivated this research. In this study, the synthesis, characterization and assessment of alkaline metal niobates as catalysts for soot combustion are reported. The solids MNbO 3 (M = Li, Na, K, Rb) are synthesized by a citrate method, calcined at 450 °C, 550 °C, 650 °C, 750 °C, and characterized by AAS, N 2 adsorption, XRD, O 2 -TPD, FTIR and SEM. All the alkaline niobates show catalytic activity for soot combustion, and the activity depends basically on the nature of the alkaline metal and the calcination temperature. The highest catalytic activity, expressed as the temperature at which combustion of carbon black occurs at the maximum rate, is shown by KNbO 3 calcined at 650 °C. At this calcination temperature, the catalytic activity follows an order dependent on the atomic number, namely: KNbO 3 > NaNbO 3 > LiNbO 3 . The RbNbO 3 solid do not follow this trend presumably due to the perovskite structure was not reached. The highest catalytic activity shown by of KNbO 3 , despite the lower apparent activation energy of NaNbO 3 , stress the importance of the metal nature and suggests the hypothesis that K + ions are the active sites for soot combustion. It must be pointed out that alkaline niobate subjected to consecutive soot combustion cycles does not show deactivation by metal loss, due to the stabilization of the alkaline metal inside the perovskite structure.

  4. Preventive maintenance basis: Volume 24 -- Battery -- flooded lead-acid (lead-calcium, lead antimony, plante). Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-12-01

    US nuclear power plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This document provides a program of preventive maintenance tasks suitable for application to flooded lead-acid batteries. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. This document provides a program of preventive maintenance (PM) tasks suitable for application to flooded lead-acid batteries. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, system engineers, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs

  5. Lead-Binding Proteins: A Review

    Directory of Open Access Journals (Sweden)

    Harvey C. Gonick

    2011-01-01

    Full Text Available Lead-binding proteins are a series of low molecular weight proteins, analogous to metallothionein, which segregate lead in a nontoxic form in several organs (kidney, brain, lung, liver, erythrocyte. Whether the lead-binding proteins in every organ are identical or different remains to be determined. In the erythrocyte, delta-aminolevulinic acid dehydratase (ALAD isoforms have commanded the greatest attention as proteins and enzymes that are both inhibitable and inducible by lead. ALAD-2, although it binds lead to a greater degree than ALAD-1, appears to bind lead in a less toxic form. What may be of greater significance is that a low molecular weight lead-binding protein, approximately 10 kDa, appears in the erythrocyte once blood lead exceeds 39 μg/dL and eventually surpasses the lead-binding capacity of ALAD. In brain and kidney of environmentally exposed humans and animals, a cytoplasmic lead-binding protein has been identified as thymosin β4, a 5 kDa protein. In kidney, but not brain, another lead-binding protein has been identified as acyl-CoA binding protein, a 9 kDa protein. Each of these proteins, when coincubated with liver ALAD and titrated with lead, diminishes the inhibition of ALAD by lead, verifying their ability to segregate lead in a nontoxic form.

  6. Gas cooled leads

    International Nuclear Information System (INIS)

    Shutt, R.P.; Rehak, M.L.; Hornik, K.E.

    1993-01-01

    The intent of this paper is to cover as completely as possible and in sufficient detail the topics relevant to lead design. The first part identifies the problems associated with lead design, states the mathematical formulation, and shows the results of numerical and analytical solutions. The second part presents the results of a parametric study whose object is to determine the best choice for cooling method, material, and geometry. These findings axe applied in a third part to the design of high-current leads whose end temperatures are determined from the surrounding equipment. It is found that cooling method or improved heat transfer are not critical once good heat exchange is established. The range 5 5 but extends over a large of values. Mass flow needed to prevent thermal runaway varies linearly with current above a given threshold. Below that value, the mass flow is constant with current. Transient analysis shows no evidence of hysteresis. If cooling is interrupted, the mass flow needed to restore the lead to its initially cooled state grows exponentially with the time that the lead was left without cooling

  7. EPA Leads the Way on Lead Exposure Science and Risk Management

    Science.gov (United States)

    EPA researchers have developed a modeling approach that improves our understanding of the relationship between lead concentrations of various sources (drinking water, soil and dust, food, and air) and children’s blood-lead levels.

  8. Lead Poisoning (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Lead Poisoning KidsHealth / For Parents / Lead Poisoning What's in ... Print en español La intoxicación por plomo About Lead Poisoning If you have young kids, it's important ...

  9. VOLUMETRIC LEAD ASSAY

    International Nuclear Information System (INIS)

    Ebadian, M.A.; Dua, S.K.; Roelant, David; Kumar, Sachin

    2001-01-01

    This report describes a system for handling and radioassay of lead, consisting of a robot, a conveyor, and a gamma spectrometer. The report also presents a cost-benefit analysis of options: radioassay and recycling lead vs. disposal as waste

  10. EMERGING TECHNOLOGY BULLETIN: RECLAMATION OF LEAD FROM SUPERFUND WASTE MATERIAL USING SECONDARY LEAD SMELTERS

    Science.gov (United States)

    This process involves incorporating lead-contaminated Superfund waste with the regular feed to a secondary lead smelter. Since secondary lead smelters already recover lead from recycled automobile batteries, it seems likely that this technology could be used to treat waste from ...

  11. Biological fractionation of lead isotopes in Sprague-Dawley rats lead poisoned via the respiratory tract.

    Science.gov (United States)

    Wu, Jing; Liu, Duojian; Xie, Qing; Wang, Jingyu

    2012-01-01

    It was considered that lead isotope ratios did not change during physical, chemical, or biological processes. Thus, lead isotope ratios have been used as fingerprints to identify possible lead sources. However, recent evidence has shown that the lead isotope ratios among different biological samples in human are not always identical from its lead origins in vitro. An animal experiment was conducted to explore the biological fractionation of lead isotopes in biological systems. 24 male Sprague-Dawley (SD) rats were divided into groups that received acute lead exposure (0, 0.02, 0.2, or 2 mg/kg body weight of lead acetate) via the respiratory route every day for 5 days. Biological samples (i.e., blood, urine, and feces) were collected for comparison with the lead acetate (test substance) and the low-lead animal feed (diet) administered to the rats. The lead isotope ratios were determined by inductively coupled plasma mass spectrometry (ICP-MS). There are significant differences (pblood, urine, and feces. Moreover, a nonlinear relationship between the blood lead concentration and the blood lead isotope ratios was observed. There is also a threshold effect to the fractionation function. Only the blood isotope ratio of (204)Pb/(206)Pb matches the test substance well. As for feces, when (204)Pb/(206)Pb ratio is considered, there is no significant difference between feces-test substance pairs in medium and high dose group. The biological fractionation of lead isotopes in SD rats was observed. Moreover, there might be a threshold for the biological fractionation of lead isotopes which is depending on whole blood lead level. It is considered to be more reliable that we compared the isotope ratios of potential lead hazards with both blood and feces lead fingerprints especially for (204)Pb/(206)Pb ratio under high-dose exposure.

  12. Two cases of acute lead poisoning due to occupational exposure to lead.

    Science.gov (United States)

    Ogawa, Masanori; Nakajima, Yoshiaki; Kubota, Ryuichi; Endo, Yoko

    2008-04-01

    We experienced two cases of acute lead poisoning due to occupational exposure to lead. The patients were engaged in stripping off antirust compounds including Pb from a bridge and re-painting it at the same work place. Both patients exhibited colic, arthralgia, and anemia. Blood lead levels were 73.1 microg/dl and 96.3 microg/dl. Intravenous CaEDTA chelation therapy was therefore performed. After chelation, blood lead levels decreased and symptoms gradually disappeared. Although the patients were working with protective equipment, the workplace was in the mountains and there was no water for washing. The patients were thus unable to washing their hands and faces. We assume that they swallowed lead dust left on their hands and faces when they removed their clothing, and believe that this poisoning occurred due to lack of knowledge sufficient for protection.

  13. Moisture damage with magnesium oxide boards in Danish facade structures

    DEFF Research Database (Denmark)

    Rode, Carsten; Bunch-Nielsen, Tommy; Hansen, Kurt Kielsgaard

    2017-01-01

    Magnesium oxide boards have been widely used on facades in Denmark during 2010-2015. However, the magnesium salts absorb humidity from the ambient, and they begin to leak salty water, which is highly corrosive, and leads to moisture and mould problems in wooden members of the structures. Mg...

  14. Arkansas People Participating in Lead Education (APPLE): results of a lead-safe training program.

    Science.gov (United States)

    Ferguson, Alesia; Bursac, Zoran; Kern, David F

    2011-06-01

    Lead is still seen as one of the most harmful environmental toxins for young children, with the predominant source being deteriorating lead-based paint. Those at continued risk include those living in homes built before 1978, renovators and remodelers, and especially those with limited access to proper healthcare and diets. Proper training on lead-safe work practices focused on preventing and reducing the spread of lead dust can help reduce lead exposure. Presented in this paper are experiences in delivering lead-safe work practices training in six Arkansas cities, and results from pre- and post- surveys delivered before and immediately after the training. Pre- and post-surveys assess strong and weak areas of training. Participants demonstrated positive shifts in attitude and behavior towards lead-safe work practices following training. However, our research found that more emphasis should be focused on clarifying current lead exposure sources and routes for children.

  15. Magnesium analysis. Determination of 5 elements by impulse polarography

    International Nuclear Information System (INIS)

    Anon.

    Determination of cadmium, copper, nickel, lead and zinc in magnesium used in magnesiothermics. The process is as follow: magnesium dissolution in hydrochloric acid, neutralisation by ammonia, addition of ammonium chloride and citric acid, ammonia is added until pH8. Addition of pyridine, polarographic determination of zinc and then of cadmium and copper [fr

  16. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions

    International Nuclear Information System (INIS)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-01-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM 2.5 ), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM 2.5 are significantly higher than them in the surface soil and street dust (p  206 Pb/ 207 Pb vs. 208 Pb/ 206 Pb and 206 Pb/ 207 Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM 2.5 ) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM 2.5 ), while the deposition of airborne lead is an important lead source for urban surface soil. - Highlights: • Lead levels and isotope ratios in atmospheric particles, street dust and surface soil. • Significant enrichment of lead in atmospheric particles was observed. • Street dust and atmospheric particles have similar lead sources. • Endmembers of soil lead differ from street dust and atmospheric particles. • Airborne lead poses the main risks to unban environmental quality. - Transfer of airborne particle bound lead into street dust and surface soil in unban environmental based on lead levels and isotopic compositions

  17. X-ray analysis of phase coexistence and electric poling processing in alkaline niobate-based compositions

    International Nuclear Information System (INIS)

    Fu Jian; Zuo Ruzhong; Liu Yi

    2010-01-01

    The characteristic and origin of two-phase coexistence and the content of each phase in typical alkaline niobate-based lead-free compositions were investigated through the refinement of X-ray diffraction peaks and the measurement of dielectric constant versus temperature curves. The diffuse nature of polymorphic phase transition has resulted in the coexistence of two ferroelectric phases within a wide composition and temperature range. As a result, the optimum piezoelectric properties appear in the composition rich in tetragonal phases and there is a remarkable poling temperature effect. Discussions on the difference between morphotropic phase boundary and polymorphic phase boundary were made in combination with the variation of electrical properties.

  18. The use of one-dimensional Niobate to improve MgH{sub 2} hydrogen sorption

    Energy Technology Data Exchange (ETDEWEB)

    Brum, M.C., E-mail: mbrum@metalmat.ufrj.br; Conceição, M.O.T. da; Jardim, P.M.; Santos, D.S. dos

    2014-12-05

    Highlights: • The 1-D Niobate W and Niobate C catalysts were synthesized. • The composites MgH{sub 2} + 5 wt.% catalysts were obtained by 20 min of mechanical milling. • The synthesized wired-like material 1-D Niobate W showed to be a promising catalyst. • A desorption capacity of 6.0 wt.%. of H{sub 2} was attained in 10 min with MgH{sub 2} + 5 wt.% 1-D Niobate W. - Abstract: A study was performed on the hydrogen absorption/desorption properties of MgH{sub 2} with the addition of Niobates synthesized by hydrothermal treatment of Nb{sub 2}O{sub 5} in 10 M NaOH. Scanning Electron Microscopy (SEM) and X-ray diffraction (XRD) were used to evaluate their synthesis and show the morphological and crystallographic differences between Nb{sub 2}O{sub 5} used as a precursor and the Niobates produced, the one-dimensional wired type, 1-D Niobate W and the cuboid one, Niobate C. The ball milling of MgH{sub 2} with the Niobates was performed within only 20 min and afterwards the Differential Scanning Calorimetry (DSC) examination of MgH{sub 2} + 1-D Niobate W and MgH{sub 2} + Niobate C showed the shifting of the peaks for both composites in comparison to pure MgH{sub 2}. The influence of the two different types of Niobates and also the Nb{sub 2}O{sub 5} on the hydrogen absorption/desorption capacity was evaluated at 350 °C. The higher absorption and desorption values were attained by the MgH{sub 2} + 5 wt.% 1-D Niobate W composite, reaching, in 10 min, approximately 5.0 wt.% and 6.0 wt.%, respectively. The possible mechanism involved in such property improvement upon adding niobium based catalysts with different morphology and structure was discussed.

  19. Lead pollution sources and Impacts

    International Nuclear Information System (INIS)

    El-Haggar, S.M.; Saad, S.G.; Saleh, S.K.; El-Kady, M.A.

    1996-01-01

    Despite the medical awareness of lead toxicity, and despite legislation designed to reduce environmental contamination, lead is one of the most widely used heavy metals. Significant human exposure occurs from automobile exhaust fumes, cigarette smoking, lead-based paints and plumbing systems lead spread in the environment can take place in several ways, the most important of which is through the lead compounds released in automobile exhaust as a direct result of the addition of tetraethyl or tetraethyl lead to gasoline as octane boosting agents. Of special is the effect of lead pollution on children, which affects their behavioral and educational attributes considerably. The major channel through through which lead is absorbed is through inhalation of lead compounds in the atmosphere. Lead is a heavy metal characterized its malleability, ductility and poor conduction of electricity. So, it has a wide range of applications ranging from battery manufacturing to glazing ceramics. It is rarely found free in nature but is present in several minerals and compounds. The aim of this paper is to discuss natural and anthropogenic sources of lead together with its distribution and trends with emphasis on egypt. The effects of lead pollution on human health, vegetation and welfare are also presented. It could be concluded that, the excessive release of lead into the environment, especially through the atmosphere, can produce many detrimental and sometimes fatal effects on human, agriculture and zoological life. Besides, it is very plain that there is a serious problem of pollution lead in egypt and specially in cairo. 7 figs

  20. Eryptosis in lead-exposed workers.

    Science.gov (United States)

    Aguilar-Dorado, Itzel-Citlalli; Hernández, Gerardo; Quintanar-Escorza, Martha-Angelica; Maldonado-Vega, María; Rosas-Flores, Margarita; Calderón-Salinas, José-Víctor

    2014-12-01

    Eryptosis is a physiological phenomenon in which old and damaged erythrocytes are removed from circulation. Erythrocytes incubated with lead have exhibited major eryptosis. In the present work we found evidence of high levels of eryptosis in lead exposed workers possibly via oxidation. Blood samples were taken from 40 male workers exposed to lead (mean blood lead concentration 64.8μg/dl) and non-exposed workers (4.2μg/dl). The exposure to lead produced an intoxication characterized by 88.3% less δ-aminolevulinic acid dehydratase (δALAD) activity in lead exposed workers with respect to non-lead exposed workers. An increment of oxidation in lead exposed workers was characterized by 2.4 times higher thiobarbituric acid-reactive substance (TBARS) concentration and 32.8% lower reduced/oxidized glutathione (GSH/GSSG) ratio. Oxidative stress in erythrocytes of lead exposed workers is expressed in 192% higher free calcium concentration [Ca(2+)]i and 1.6 times higher μ-calpain activity with respect to non-lead exposed workers. The adenosine triphosphate (ATP) concentration was not significantly different between the two worker groups. No externalization of phosphatidylserine (PS) was found in non-lead exposed workers (lead exposed workers showed 2.82% externalization. Lead intoxication induces eryptosis possibly through a molecular pathway that includes oxidation, depletion of reduced glutathione (GSH), increment of [Ca(2+)], μ-calpain activation and externalization of PS in erythrocytes. Identifying molecular signals that induce eryptosis in lead intoxication is necessary to understand its physiopathology and chronic complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. What is lead-based paint?

    International Nuclear Information System (INIS)

    Vernon, L.S.

    1994-01-01

    The number of variety of lead-abatement regulations and requirements make it difficult and confusing to identify and properly respond to dangerous levels of lead in every situation. Definitions of ''lead-based paint'' and three test methods for lead detection are described to help determine when and how to test for the presence of lead

  2. Lead identification in soil surrounding a used lead acid battery smelter area in Banten, Indonesia

    International Nuclear Information System (INIS)

    Adventini, N; Santoso, M; Lestiani, D D; Syahfitri, W Y N; Rixson, L

    2017-01-01

    A used lead acid battery smelter generates particulates containing lead that can contaminate the surrounding environment area. Lead is a heavy metal which is harmful to health if it enters the human body through soil, air, or water. An identification of lead in soil samples surrounding formal and informal used lead acid battery smelters area in Banten, Indonesia using EDXRF has been carried out. The EDXRF accuracy and precision evaluated from marine sediment IAEA 457 gave a good agreement to the certified value. A number of 16 soil samples from formal and informal areas and 2 soil samples from control area were taken from surface and subsurface soils. The highest lead concentrations from both lead smelter were approximately 9 folds and 11 folds higher than the reference and control samples. The assessment of lead contamination in soils described in C f index was in category: moderately and strongly polluted by lead for formal and informal lead smelter. Daily lead intake of children in this study from all sites had exceeded the recommended dietary allowance. The HI values for adults and children living near both lead smelter areas were greater than the value of safety threshold 1. This study finding confirmed that there is a potential health risk for inhabitants surrounding the used lead acid battery smelter areas in Banten, Indonesia. (paper)

  3. Stable lead isotopic analyses of historic and contemporary lead contamination of San Francisco Bay estuary

    Science.gov (United States)

    Ritson, P.I.; Bouse, R.M.; Flegal, A.R.; Luoma, S.N.

    1999-01-01

    Variations in stable lead isotopic composition (240Pb, 206Pb, 207Pb, 208Pb) in three sediment cores from the San Francisco Bay estuary document temporal changes in sources of lead during the past two centuries. Sediment, with lead from natural geologic sources, and relatively homogeneous lead isotopic compositions are overlain by sediments whose isotopic compositions indicate change in the sources of lead associated with anthropogenic modification of the estuary. The first perturbations of lead isotopic composition in the cores occur in the late 1800s concordant with the beginning of industrialization around the estuary. Large isotopic shifts, toward lower 206Pb/207Pb, occur after the turn of the century in both Richardson and San Pablo Bays. A similar relationship among lead isotopic compositions and lead concentrations in both Bays suggest contamination from the same source (a lead smelter). The uppermost sediments (post 1980) of all cores also have a relatively homogenous lead isotopic composition distinct from pre-anthropogenic and recent aerosol signatures. Lead isotopic compositions of leachates from fourteen surface sediments and five marsh samples from the estuary were also analyzed. These analyses suggest that the lead isotopic signature identified in the upper horizons of the cores is spatially homogeneous among recently deposited sediments throughout the estuary. Current aerosol lead isotopic compositions [Smith, D.R., Niemeyer, S., Flegal, A.R., 1992. Lead sources to California sea otters: industrial inputs circumvent natural lead biodepletion mechanisms. Environmental Research 57, 163-175] are distinct from the isotopic compositions of the surface sediments, suggesting that the major source of lead is cycling of historically contaminated sediments back through the water column. Both the upper core sediments and surface sediments apparently derive their lead predominantly from sources internal to the estuary. These results support the idea that

  4. Heavy flavour production in proton-lead and lead-lead collisions with LHCb

    Science.gov (United States)

    Winn, Michael

    2017-11-01

    The LHCb experiment offers the unique opportunity to study heavy-ion interactions in the forward region (2 kinematic domain complementary to the other 3 large experiments at the LHC. The detector has excellent capabilities for reconstructing quarkonia and open charm states, including baryons, down to zero pT. It can separate the prompt and displaced charm components. In pPb collisions, both forward and backward rapidities are covered thanks to the possibility of beam reversal. Results include measurements of the nuclear modification factor and forward-backward ratio for charmonium, open charm and bottomonium states. These quantities are sensitive probes for nuclear effects in heavy flavour production. Perspectives are given with the large accumulated luminosity during the 2016 pPb run at the LHC. In 2015, LHCb participated successfully for the first time in the PbPb data-taking. The status of the forward prompt J/ψ nuclear modification factor measurement in lead-lead collisions is discussed.

  5. Electric-regulated enhanced in-plane uniaxial anisotropy in FeGa/PMN-PT composite using oblique pulsed laser deposition

    Science.gov (United States)

    Zhang, Yi; Huang, Chaojuan; Turghun, Mutellip; Duan, Zhihua; Wang, Feifei; Shi, Wangzhou

    2018-04-01

    The FeGa film with in-plane uniaxial magnetic anisotropy was fabricated onto different oriented single-crystal lead magnesium niobate-lead titanate using oblique pulsed laser deposition. An enhanced in-plane uniaxial magnetic anisotropy field of FeGa film can be adjusted from 18 Oe to 275 Oe by tuning the oblique angle and polarizing voltage. The competitive relationship of shape anisotropy and strain anisotropy has been discussed, which was induced by oblique angle and polarizing voltage, respectively. The (100)-oriented and (110)-oriented PMN-PT show completely different characters on voltage-dependent magnetic properties, which could be attributed to various anisotropy directions depended on different strain directions.

  6. Large microwave tunability of GaAs-based multiferroic heterostructure for applications in monolithic microwave integrated circuits

    International Nuclear Information System (INIS)

    Chen Yajie; Gao Jinsheng; Vittoria, C; Harris, V G; Heiman, D

    2010-01-01

    Microwave magnetoelectric coupling in a ferroelectric/ferromagnetic/semiconductor multiferroic (MF) heterostructure, consisting of a Co 2 MnAl epitaxial film grown on a GaAs substrate bonded to a lead magnesium niobate-lead titanate (PMN-PT) crystal, is reported. Ferromagnetic resonance measurements were carried out at X-band under the application of electric fields. Results indicate a frequency tuning of 125 MHz for electric field strength of 8 kV cm -1 resulting in a magnetoelectric coupling coefficient of 3.4 Oe cm kV -1 . This work explores the potential of electronically controlled MF devices for use in future monolithic microwave integrated circuits.

  7. Comparison of different bonding techniques for efficient strain transfer using piezoelectric actuators

    Science.gov (United States)

    Ziss, Dorian; Martín-Sánchez, Javier; Lettner, Thomas; Halilovic, Alma; Trevisi, Giovanna; Trotta, Rinaldo; Rastelli, Armando; Stangl, Julian

    2017-04-01

    In this paper, strain transfer efficiencies from a single crystalline piezoelectric lead magnesium niobate-lead titanate substrate to a GaAs semiconductor membrane bonded on top are investigated using state-of-the-art x-ray diffraction (XRD) techniques and finite-element-method (FEM) simulations. Two different bonding techniques are studied, namely, gold-thermo-compression and polymer-based SU8 bonding. Our results show a much higher strain-transfer for the "soft" SU8 bonding in comparison to the "hard" bonding via gold-thermo-compression. A comparison between the XRD results and FEM simulations allows us to explain this unexpected result with the presence of complex interface structures between the different layers.

  8. Ecotoxicology: Lead

    Science.gov (United States)

    Scheuhammer, A.M.; Beyer, W.N.; Schmitt, C.J.; Jorgensen, Sven Erik; Fath, Brian D.

    2008-01-01

    Lead (Pb) is a naturally occurring metallic element; trace concentrations are found in all environmental media and in all living things. However, certain human activities, especially base metal mining and smelting; combustion of leaded gasoline; the use of Pb in hunting, target shooting, and recreational angling; the use of Pb-based paints; and the uncontrolled disposal of Pb-containing products such as old vehicle batteries and electronic devices have resulted in increased environmental levels of Pb, and have created risks for Pb exposure and toxicity in invertebrates, fish, and wildlife in some ecosystems.

  9. Developmental immunotoxicology of lead

    International Nuclear Information System (INIS)

    Dietert, Rodney R.; Lee, Ji-Eun; Hussain, Irshad; Piepenbrink, Michael

    2004-01-01

    The heavy metal, lead, is a known developmental immunotoxicant that has been shown to produce immune alterations in humans as well as other species. Unlike many compounds that exert adverse immune effects, lead exposure at low to moderate levels does not produce widespread loss of immune cells. In contrast, changes resulting from lead exposure are subtle at the immune cell population level but, nevertheless, can be functionally dramatic. A hallmark of lead-induced immunotoxicity is a pronounced shift in the balance in T helper cell function toward T helper 2 responses at the expense of T helper 1 functions. This bias alters the nature and range of immune responses that can be produced thereby influencing host susceptibility to various diseases. Immunotoxic responses to lead appear to differ across life stages not only quantitatively with regard to dose response, but also qualitatively in terms of the spectrum of immune alterations. Experimental studies in several lab animal species suggest the latter stages of gestation are a period of considerable sensitivity for lead-induced immunotoxicity. This review describes the basic characteristics of lead-induced immunotoxicity emphasizing experimental animal results. It also provides a framework for the consideration of toxicant exposure effects across life stages. The existence of and probable basis for developmental windows of immune hyper-susceptibility are presented. Finally, the potential for lead to serve as a perinatal risk factor for childhood asthma as well as other diseases is considered

  10. High Burden of Subclinical Lead Toxicity after Phase Out of Lead from Petroleum in Pakistan.

    Science.gov (United States)

    Majid, Hafsa; Khan, Aysha Habib; Khan, Nadeem Ullah; Siddiqui, Imran; Ghani, Farooq; Jafri, Lena

    2017-12-01

    To evaluate the frequency of subclinical lead toxicity. Cross-sectional study. Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Karachi, from January 2011 to December 2014. Analysis of laboratory data for blood lead levels (BLL) was performed. Lead was tested by atomic absorption spectrometer. For all subjects, only initial test results were included while the results of repeated testing were excluded. Exemption was sought from institutional ethical review committee. BLL of 2-10 ug/dl and 10-70 ug/dl in children and adults, respectively were taken as subclinical lead toxicity. Amongst the total number of subjects tested (n=524), 26.5% (n=139) were children (lead level 16.9 ug/dl (36.1-4)] and lower level [4.2 ug/dl (6.8-2.6)] in children with lead levels while most had either subclinical (76%, n=106) or toxic lead levels (8%, n=11). In adults, (55%, n=212) subjects had desired lead levels, and 40% (n=154) and 4.99% (n=19) had subclinical and toxic lead levels. Presence of subclinical lead poisoning even after phasing out of lead petroleum in Pakistanis is alarming, especially in children. A national population-based study to determine the lead status and targeted intervention to identify potential sources is need of the time.

  11. Lead isotopes reveal different sources of lead in balsamic and other vinegars

    International Nuclear Information System (INIS)

    Ndung'u, Kuria; Hibdon, Sharon; Veron, Alain; Flegal, A. Russell

    2011-01-01

    Fifty-eight brands of balsamic vinegars were analyzed for lead concentrations and isotopic compositions ( 204 Pb, 206 Pb, 207 Pb, and 208 Pb) to test the findings of a previous study indicating relatively high levels of lead contamination in some of those vinegars - more than two thirds (70%) of them exceeded California's State Maximum Level (34 μg/L) based on consumption rates ≥ 0.5 μg Pb per day. The Lead isotopic fingerprints of all those vinegars with high lead concentrations were then found to be primarily anthropogenic. This isotopic analysis unquestionably reveals multiple contamination sources including atmospheric pollutant Pb and an unidentified contamination source, likely occurring after grape harvest. Organically grown grape vinegars display the same Pb content and isotopic signatures as other vinegars. This implies that pesticides might not be a significant source of pollutant Pb in vinegars. A significant post-harvest contamination would be inherited from chemicals added during production and/or material used during transport, processing or storage of these vinegars. This is consistent with the highest Pb levels being found in aged vinegars (112 ± 112 μg/L) in contrast to other vinegars (41.6 ± 28.9 μg/L) suggesting contamination during storage. It is, therefore, projected that lead levels in most vinegars, especially aged balsamic and wine vinegars, will decrease with improvements in their manufacture and storage processes consequential to recent concerns of elevated levels of lead in some vinegars. - Highlights: → First extensive study on content and possible sources of lead in balsamic vinegars. → Half of the vinegars exceed California's State Maximum Level for human consumption. → Lead content in vinegars seems to be mainly post-harvest from industrial processes.

  12. Safety and Health Topics: Lead

    Science.gov (United States)

    ... ammunition, pipes, cable covering, building material, solder, radiation shielding, collapsible tubes, and fishing weights. Lead is also ... lead linings in tanks and radiation protection, leaded glass, work involving soldering, and other work involving lead ...

  13. High-temperature thermal conductivity of uranium chromite and uranium niobate

    International Nuclear Information System (INIS)

    Fedoseev, D.V.; Varshavskaya, I.G.; Lavrent'ev, A.V.; Oziraner, S.N.; Kuznetsova, D.G.

    1979-01-01

    The technique of determining thermal conductivity coefficient of uranium niobate and uranium chromite on heating with laser radiation is described. Determined is the coefficient of free-convective heat transfer (with provision for a conduction component) by means of a standard specimen. The thermal conductivity coefficients of uranium chromite and niobate were measured in the 1300-1700 K temperature range. The results are presented in a diagram form. It has been calculated, that the thermal conductivity coefficient for uranium niobate specimens is greater in comparison with uranium chromite specimens. The thermal conductivity coefficients of the materials mentioned depend on temperature very slightly. Thermal conductivity of the materials considerably depends on their porosity. The specimens under investigation were fabricated by the pressing method and had the following porosity: uranium chromite - 30 %, uranium niobate - 10 %. Calculation results show, that thermal conductivity of dense uranium chromite is higher than thermal conductivity of dense uranium niobate. The experimental error equals approximately 20 %, that is mainly due to the error of measuring the temperature equal to +-25 deg, with a micropyrometer

  14. Leading by example to protect the environment : Do the costs of leading matter?

    NARCIS (Netherlands)

    van der Heijden, E.C.M.; Moxnes, E.

    2013-01-01

    Environmentalists often urge their home countries to take a leading role in reducing global environmental problems like climate change. A pertinent question is, Will examples set by leading nations influence others to follow suit, and if so, do the costs of leading matter? For instance, will costly

  15. Leading by Example to Protect the Environment; Do the Costs of Leading Matter?

    NARCIS (Netherlands)

    van der Heijden, E.C.M.; Moxnes, E.

    2011-01-01

    Environmentalists often urge their home countries to take a leading role in reducing global environmental problems like climate change. A pertinent question is: will examples set by leading nations influence others to follow suit, and if so, do the costs of leading matter? For instance, will costly

  16. Decontaminating lead bricks and shielding

    International Nuclear Information System (INIS)

    Lussiez, G.

    1994-01-01

    Lead used for shielding is often surface contaminated with radioisotopes and is therefore a RCRA D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Laboratory decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 50 tons and likely to grow substantially of planned decommissioning operations. Thus lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for contaminated lead is removing the superficial layer of contamination with an abrasive medium under pressure. For lead, a mixture of alumina with water and air at about 40 psig rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a scaled-off area. The slurry of abrasive and particles of lead falls through a floor and is collected in a sump. A pump sends the slurry mixture back to the spray gun, creating a continuous process. The process generates small volumes of lead slurry that can be solidified and, because it passes the TCLP, is not a mixed waste. The decontaminated lead can be released for recycling

  17. High-temperature superconducting current leads

    Science.gov (United States)

    Hull, J. R.

    1992-07-01

    The use of high-temperature superconductors (HTSs) for current leads to deliver power to devices at liquid helium temperature is near commercial realization. The use of HTSs in this application has the potential to reduce refrigeration requirements and helium boiloff to values significantly lower than the theoretical best achievable with conventional leads. Considerable advantage is achieved by operating these leads with an intermediate temperature heat sink. The HTS part of the lead can be made from pressed and sintered powder. Powder-in-tube fabrication is also possible, however, the normal metal part of the lead acts as a thermal short and cannot provide much stabilization without increasing the refrigeration required. Lead stability favors designs with low current density. Such leads can be manufactured with today's technology, and lower refrigeration results from the same allowable burnout time. Higher current densities result in lower boiloff for the same lead length, but bumout times can be very short. In comparing experiment to theory, the density of helium vapor needs to be accounted for in calculating the expected boiloff. For very low-loss leads, two-dimensional heat transfer and the state of the dewar near the leads may play a dominant role in lead performance.

  18. Lead, arsenic, and copper content of crops grown on lead arsenate-treated and untreated soils

    Energy Technology Data Exchange (ETDEWEB)

    Chisholm, D

    1972-01-01

    Increased lead and arsenic concentrations in the surface soil (0-15 cm), resulting from applications of lead arsenate (PbHAs0/sub 1/), increased both lead and arsenic levels in crops grown on treated plots. The lead levels in some crops approached or exceeded the Canadian residue tolerance of 2.0 ppM. Lead arsenate soil treatments did not affect copper absorption by crops. On areas such as old orchard land contaminated with lead arsenate residues it may be advisable to ascertain crops, and also to determine the lead affinity and arsenic sensitivity of the plants to be grown.

  19. Lead poisoning in dogs

    International Nuclear Information System (INIS)

    Zook, B.C.; Carpenter, J.L.; Leeds, E.B.

    1969-01-01

    Lead poisoning was diagnosed and studied in 60 dogs. It was found that lead poisoning is a common disease of young dogs, especially in the summer and fall, and is related to their chewing and eating habits resulting in the ingestion of paint, linoleum, or other lead-containing materials. The signs were characterized by gastrointestinal dysfunction (colic, vomiting, and diarrhea) and nervous disorders (convulsions, hysteria, nervousness, behavioral changes). The blood findings, which the authors consider nearly pathognomonic, consisted of numerous stippled and immature (especially nucleated) erythrocytes in the absence of severe anemia. Protein and casts were frequently found in the urine. Radiography sometimes revealed lead-containing particles in the gastro-intestinal tract, and lead lines were occasionally detected in the metaphysis of long bones in immature dogs. Treatment with calcium ethylenediamine-tetraacetic acid resulted in rapid and often dramatic recoveries in nearly all instances. Removal of lead from the gastrointestinal tract and treatment to relieve pronounced central nervous disorders was sometimes necessary. 40 references, 6 figures, 7 tables

  20. ALICE: Simulated lead-lead collision

    CERN Multimedia

    2003-01-01

    This track is an example of simulated data modelled for the ALICE detector on the Large Hadron Collider (LHC) at CERN, which will begin taking data in 2008. ALICE will focus on the study of collisions between nuclei of lead, a heavy element that produces many different particles when collided. It is hoped that these collisions will produce a new state of matter known as the quark-gluon plasma, which existed billionths of a second after the Big Bang.

  1. Experimental lead poisoning in chickens

    Energy Technology Data Exchange (ETDEWEB)

    Silven, L.

    1967-01-01

    Poisoning of water fowl due to the intake of lead shot is not rare in the USA. In order to study this kind of poisoning more closely domestic fowl were given varying amounts of lead shot and lead powder. This treatment did not provoke any symptoms of poisoning. Chemical analyses of different organs, muscles, skeleton and eggs yielded low lead values. It is concluded that the low toxicity of lead administered as lead shot to the domestic fowl is due to a low absorption rate from the gastro-intestinal tract.

  2. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Vernon G., E-mail: vthomas@uoguelph.ca [Department of Integrative Biology, College of Biological Science, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada); Scheuhammer, Anton M.; Bond, Della E. [Metals Toxicology Laboratory, National Wildlife Research Centre, Carleton University, Ottawa, Ontario, K1A 0H3 (Canada)

    2009-05-15

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  3. The effect of interior lead hazard controls on children's blood lead concentrations: a systematic evaluation.

    Science.gov (United States)

    Haynes, Erin; Lanphear, Bruce P; Tohn, Ellen; Farr, Nick; Rhoads, George G

    2002-01-01

    Dust control is often recommended to prevent children's exposure to residential lead hazards, but the effect of these controls on children's blood lead concentrations is uncertain. We conducted a systematic review of randomized, controlled trials of low-cost, lead hazard control interventions to determine the effect of lead hazard control on children's blood lead concentration. Four trials met the inclusion criteria. We examined mean blood lead concentration and elevated blood lead concentrations (> or = 10 microg/dL, > or = 15 microg/dL, and > or = 20 microg/dL) and found no significant differences in mean change in blood lead concentration for children by random group assignment (children assigned to the intervention group compared with those assigned to the control group). We found no significant difference between the intervention and control groups in the percentage of children with blood lead > or = 10 microg/dL, 29% versus 32% [odds ratio (OR), 0.85; 95% confidence interval (CI), 0.56-1.3], but there was a significant difference in the percentage of children with blood lead > or = 15 microg/dL between the intervention and control groups, 6% versus 14% (OR, 0.40; 95% CI, 0.21-0.80) and in the percentage of children with blood lead > or = 20 microg/dL between the intervention and control groups, 2% versus 6% (OR, 0.29; 95% CI, 0.10-0.85). We conclude that although low-cost, interior lead hazard control was associated with 50% or greater reduction in the proportion of children who had blood lead concentrations exceeding 15 microg/dL and > or = 20 microg/dL, there was no substantial effect on mean blood lead concentration.

  4. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    International Nuclear Information System (INIS)

    Thomas, Vernon G.; Scheuhammer, Anton M.; Bond, Della E.

    2009-01-01

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  5. Decontaminating lead bricks and shielding

    International Nuclear Information System (INIS)

    Lussiez, G.W.

    1993-01-01

    Lead used for shielding is often surface contaminated with radioisotopes and is therefore a RCRA D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Laboratory decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 50 tons and likely to grow substantially because of planned decommissioning operations. This lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for decontaminating lead is removing the thin superficial layer of contamination with an abrasive medium trader pressure. For lead, a mixture of alumina with water and air at about 40 psig rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a sealed-off area. The slurry of abrasive and particles of lead falls through a floor grating and is collected in a sump. A pump sends the slurry mixture back to the spray gun, creating a continuous process. The process generates small volumes of contaminated lead slurry that can be solidified and, because it passes the TCLP, is not a mixed waste. The decontaminated lead can be released for recycling

  6. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions.

    Science.gov (United States)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-04-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM2.5), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM2.5 are significantly higher than them in the surface soil and street dust (p lead to the major crustal elements (Al, Sr, Ti and Fe) indicates significant lead enrichment in atmospheric particles. The plots of (206)Pb/(207)Pb vs.(208)Pb/(206)Pb and (206)Pb/(207)Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM2.5) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM2.5), while the deposition of airborne lead is an important lead source for urban surface soil. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. INAA, AAS, and lead isotope analysis of ancient lead anchors from the black SEA

    International Nuclear Information System (INIS)

    Kuleff, I.; Djingova, R.; Alexandrova, A.

    1995-01-01

    Lead stock of wooden-lead anchors found along the Bulgarian Black Sea coast and typo logically dated VI c. B.C. - III c. A.D. have been analyzed for chemical composition and lead isotope ratios by INAA, AAS and mass spectrometry. Using multivariate methods for analysis as well as simple bi variate plots the lead for production of the stocks was localized as originating from Laurion, Thassos, Troas, Chalkidike and the Rhodopes. In general, the chemical composition is not recommended to be used for provenance study of lead artefacts. Combining the results from this study with the existing typo logical classification certain conclusion about the production and distribution of lead anchors in the Aegean region are made. (author). 22 refs., 3 figs., 4 tabs

  8. Horizontal and Vertical Distribution of Heavy Metals in Farm Produce and Livestock around Lead-Contaminated Goldmine in Dareta and Abare, Zamfara State, Northern Nigeria

    Directory of Open Access Journals (Sweden)

    O. E. Orisakwe

    2017-01-01

    Full Text Available Background. Hitherto studies in response to the June 2010 lead poisoning, Zamfara State, Nigeria, have focused on clinical interventions without information on livestock and other metals. Objective. This study has investigated the distribution of heavy metals in farm produce and livestock around lead-contaminated goldmine in Dareta and Abare, Zamfara State, Nigeria. Methods. Vegetables, soil, water, blood, and different meat samples were harvested from goat, sheep, cattle, and chicken from Dareta, Abare, and Gusau communities. The samples were digested with 10 mL of a mix of nitric and perchloric acids; the mixture was then heated to dryness. Lead, cadmium, zinc, chromium, copper, magnesium, and nickel were analysed using flame Atomic Absorption Spectrophotometer. The daily intake, bioaccumulation factor, and target hazard quotient (THQ were calculated. Results. Chicken bone-muscles from Dareta had the highest concentrations of lead, zinc, and nickel (28.2750, 16.1650, and 4.2700 mg/kg, resp., while chicken brain had the highest levels of cadmium, magnesium (0.3800 and 67.5400 mg/kg, and chromium (6.1650 mg/kg, kidney tissue inclusive. Conclusion. In addition to lead, cadmium may also be of concern in the contaminated mining communities of Zamfara State, Nigeria, given the high levels of cadmium in meat and vegetables samples from these areas.

  9. Atrioventricular Pacemaker Lead Reversal

    Directory of Open Access Journals (Sweden)

    Mehmet K Aktas, MD

    2007-01-01

    Full Text Available During cardiac surgery temporary epicardial atrial and ventricular leads are placed in case cardiac pacing is required postoperatively. We present the first reported series of patients with reversal of atrioventricular electrodes in the temporary pacemaker without any consequent deleterious hemodynamic effect. We review the electrocardiographic findings and discuss the findings that lead to the discovery of atrioventricular lead reversal.

  10. Lead accumulation in the straw mushroom, Volvariella volvacea, from lead contaminated rice straw and stubble.

    Science.gov (United States)

    Kumhomkul, Thapakorn; Panich-pat, Thanawan

    2013-08-01

    Straw mushrooms were grown on lead contaminated rice straw and stubble. Study materials were dried, acid digested, and analyzed for lead using flame atomic absorption spectrophotometry. The results showed the highest lead concentration in substrate was 445.350 mg kg⁻¹ in Treatment 3 (T3) and the lowest was BD (below detection) in Treatment 1 (T1). The maximum lead content in straw mushrooms was 5.072 mg kg⁻¹ dw in pileus of T3 and the minimum lead content in straw mushrooms was BD in egg and mature (stalk and pileus) stage of T1. The lead concentration in straw mushrooms was affected by the age of the mycelium and the morphology of mushrooms. Mushrooms' lead uptake produced the highest accumulation in the cell wall. Some lead concentrations in straw mushrooms exceeded the EU standard (>3 mg kg⁻¹ dw).

  11. Basic principles of lead and lead-bismuth eutectic application in blanket of fusion reactors

    International Nuclear Information System (INIS)

    Beznosov, A.V.; Pinaev, S.S.; Muraviev, E.V.; Romanov, P.V.

    2005-01-01

    High magnetohydrodynamic pressure drop is an important issue for liquid metal blanket concepts. To decrease magnetohydrodynamic resistance authors propose to form insulating coatings on internal surface of blanket ducts at any moment of fusion reactor exploitation. It may be achieved easily if lead or lead-bismuth eutectic is used and technology of oxidative potential handling is applied. A number of experiments carried out in NNSTU show the availability of the proposed technology. It bases on formation of the insulating coatings that consist of the oxides of components of the structural materials and of the coolant components. In-situ value of the insulating coatings characteristics ρδ is ∼ 10 -5 Ohm·m 2 for steels and 5,0x10 -6 - 5,0x10 -5 Ohm·m 2 for vanadium alloys. Thermal cycling is possible during exploitation of a blanket. The experimental research of the insulating coatings properties during thermal cycling have shown that the coatings formed into the lead and lead-bismuth coolants save there insulating properties. Experience of many years is an undoubted advantage of the lead-bismuth coolant and less of the lead coolant in comparison with lithium. Russian Federation possesses of experience of exploitation of the research and industrial facilities, of experience of creation of the pumps, steamgenerators and equipment with heavy liquid metal coolants. The unique experience of designing, assembling and exploitation of the fission reactors with lead-bismuth coolant is also available. The problem of technology of lead and lead-bismuth coolants for power high temperature radioactive facilities has been solved. Accidents, emergency situations such as leakage of steamgenerators or depressurization of gas system in facilities with lead and lead-bismuth coolants have been explored and suppressed. (author)

  12. Manurial properties of lead nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Berry, R A

    1924-01-01

    Water culture, pot and field experiments were conducted in order to determine the toxic and stimulating limit of lead nitrate in solution. Oats and rye grass were evaluated for evidence of lead poisoning. Results indicate that except in solutions of fairly high concentration, soil adsorbs the lead and destroys the toxicity of soluble lead salts. There was evidence to show that the addition of lead salts increased the rate of nitrification in soil.

  13. Children’s Blood Lead Seasonality in Flint, Michigan (USA), and Soil-Sourced Lead Hazard Risks

    Science.gov (United States)

    Laidlaw, Mark A.S.; Filippelli, Gabriel M.; Sadler, Richard C.; Gonzales, Christopher R.; Ball, Andrew S.; Mielke, Howard W.

    2016-01-01

    In Flint; MI; USA; a public health crisis resulted from the switching of the water supply from Lake Huron to a more corrosive source from the Flint River in April 2014; which caused lead to leach from water lines. Between 2010 and 2015; Flint area children’s average blood lead patterns display consistent peaks in the third quarter of the year. The third quarter blood lead peaks displayed a declining trend between 2010 and 2013; then rose abruptly between the third quarters of 2013 from 3.6% blood lead levels ≥5 µg/dL to a peak of about 7% in the third quarter of 2014; an increase of approximately 50%. The percentage of blood lead level ≥5 µg/dL in the first quarter of 2015 then dropped to 2.3%; which was the same percentage as the first quarter of 2014 (prior to the Flint River water source change). The Flint quarterly blood lead level peak then rose to about 6% blood lead levels ≥ 5 µg/dL in the third quarter of 2015; and then declined to about 2.5% in the fourth quarter of 2015. Soil lead data collected by Edible Flint food collaborative reveal generally higher soil lead values in the metropolitan center for Flint; with lower values in the outskirts of the city. The questions that are not being asked is why did children’s blood lead levels display a seasonal blood lead pattern before the introduction of the new water supply in Flint; and what are the implications of these seasonal blood lead patterns? Based upon previous findings in Detroit and other North American cities we infer that resuspension to the air of lead in the form of dust from lead contaminated soils in Flint appears to be a persistent contribution to lead exposure of Flint children even before the change in the water supply from Lake Huron to the Flint River. PMID:27023578

  14. Micro- and nanostructuration of lithium niobate

    International Nuclear Information System (INIS)

    Hartung, Holger

    2010-01-01

    In the framework of this thesis the application of the ion-beam-enhanced-etching (IBEE) technique for the fabrication of different optical elements, among these photonic crystals, in lithium niobate, was studied. The development of a mask technology fitted to the requirements of the IBEE technique as well as a simulation of the process were performed. Hereby the limitations of the technique in view on minimal structure sizes and structure quality were analyzed. In chapter 1 first the material lithium niobate with its properties and the structuration procedures studied hitherto in the literature is presented. Chapter 2 presents the functionality of the IBEE process and describes the studies on the application of IBEE in lithium niobate performed in the framework of this thesis. In chapter 3 the experimental conditions of all applied processes of the IBEE procedure, the processes used for the mask fabrication, as well all further applied methods and technologies are summarized. Chapter 4 deals with the mask fabrication. The requirements on the masks and the developments necessary for their fulfilment are studied. In chapter 5 the performed simulation of the irradiation, annealing, and etching process is described. This simulation makes the prediciton of the geometry of the components from the process parameters and vice versa the determination of parameters for the reaching of an optimal element geometry possible. In chapter 6 the application of the technique for the fabrication of photonic-crystal membranes and their optical characterization is described. Chapter 7 shows the fabrication of different waveguide and diffractive elements in lithium niobate by means of IBEE.

  15. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  16. Archives of Atmospheric Lead Pollution

    Science.gov (United States)

    Weiss, Dominik; Shotyk, William; Kempf, Oliver

    Environmental archives such as peat bogs, sediments, corals, trees, polar ice, plant material from herbarium collections, and human tissue material have greatly helped to assess both ancient and recent atmospheric lead deposition and its sources on a regional and global scale. In Europe detectable atmospheric lead pollution began as early as 6000years ago due to enhanced soil dust and agricultural activities, as studies of peat bogs reveal. Increased lead emissions during ancient Greek and Roman times have been recorded and identified in many long-term archives such as lake sediments in Sweden, ice cores in Greenland, and peat bogs in Spain, Switzerland, the United Kingdom, and the Netherlands. For the period since the Industrial Revolution, other archives such as corals, trees, and herbarium collections provide similar chronologies of atmospheric lead pollution, with periods of enhanced lead deposition occurring at the turn of the century and since 1950. The main sources have been industry, including coal burning, ferrous and nonferrous smelting, and open waste incineration until c.1950 and leaded gasoline use since 1950. The greatest lead emissions to the atmosphere all over Europe occurred between 1950 and 1980 due to traffic exhaust. A marked drop in atmospheric lead fluxes found in most archives since the 1980s has been attributed to the phasing out of leaded gasoline. The isotope ratios of lead in the various archives show qualitatively similar temporal changes, for example, the immediate response to the introduction and phasing out of leaded gasoline. Isotope studies largely confirm source assessments based on lead emission inventories and allow the contributions of various anthropogenic sources to be calculated.

  17. Decontaminating lead bricks and shielding

    International Nuclear Information System (INIS)

    Lussiez, G.W.

    1993-01-01

    Lead used for shielding is often surface contaminated with radionuclides and is therefore a Resource Conservation and Recovery Act (RCRA) D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Lab. decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 100 metric tons and likely to grow substantially because of planned decommissioning operations. This lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for decontaminating lead is removing the thin superficial layer of contamination with an abrasive medium under pressure. For lead, a mixture of alumina with water and air at about 280 kPa (40 psig) rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a sealed-off area. The slurry of abrasive and particles of lead falls through a floor grating and is collected in a pump. A pump sends the slurry mixture back to the spray gun, creating a continuous process

  18. Erythrocyte fluorescence and lead intoxication.

    Science.gov (United States)

    Clark, K G

    1976-01-01

    Blood samples from people exposed to inorganic lead were examined by fluorescence microscopy for excess erythrocyte porphyrin. With continued lead absorption, fluorescent erythrocytes appeared in the circulation of workers handling this metal or its compounds, and they progressively increased in number and brilliance. These changes ensued if the blood lead concentration was maintained above 2-42 mumol/l (50 mug/100 ml), and preceded any material fall in the haemoglobin value. At one factory, 62-5% of 81 symptomless workers showed erythrocyte fluorescence attributable to the toxic effects of lead. Excess fluorocytes were found in blood samples from a child with pica and three of her eight siblings. These four were subsequently shown to have slightly increased blood lead concentrations (2-03 to 2-32 mumol/l). Fluorescence microscopy for excess erythrocyte porphyrin is a sensitive method for the detection of chronic lead intoxication. A relatively slight increase in the blood lead is associated with demonstrabel changes in erythrocyte porphyrin content. The procedure requires little blood, and may be performed upon stored samples collected for lead estimation. The results are not readily influenced by contamination, and provide good confirmatory evidence for the absorption of biochemically active lead. PMID:963005

  19. Leaded gasoline - an environmental problem

    International Nuclear Information System (INIS)

    Petrushevska, Ljubica

    2001-01-01

    In the European countries it is a clear trend towards the increasing consumption of unleaded gasolines. Driving force of this trend is, on the one hand the high toxicity of lead compounds and on the other, the necessity of purification of exhaust gases by catalytic converters, for which the lead represent a catalyst poison. In Macedonia, the limit lead content in the leaded gasolines is relatively high (0,6 g/l), as well as the consumption of the leaded gasolines. Rapid and complete transition to unleaded gasolines can be realized by the concept of step by step reduction of lead in our gasolines. (Original)

  20. Decontamination and coating of lead

    International Nuclear Information System (INIS)

    Rankin, W.N.; Bush, S.P.; Lyon, C.E.; Walker, V.

    1988-01-01

    Technology is being developed to decontaminate lead used in shielding applications in contaminated environments for recycle as shieldings. Technology is also being developed to coat either decontaminated lead or new lead before it is used in contaminated environments. The surface of the coating is expected to be much easier to decontaminate than the original lead surface. If contamination becomes severely embedded in the coating and cannot be removed, it can be easily cut with a knife and removed from the lead. The used coating can be disposed of as radioactive (hot hazardous) waste. The lead can then be recoated for further use as a shielding material

  1. Contamination of wells completed in the Roubidoux aquifer by abandoned zinc and lead mines, Ottawa County, Oklahoma

    Science.gov (United States)

    Christenson, Scott C.

    1995-01-01

    The Roubidoux aquifer in Ottawa County Oklahoma is used extensively as a source of water for public supplies, commerce, industry, and rural water districts. Water in the Roubidoux aquifer in eastern Ottawa County has relatively low dissolved-solids concentrations (less than 200 mg/L) with calcium, magnesium, and bicarbonate as the major ions. The Boone Formation is stratigraphically above the Roubidoux aquifer and is the host rock for zinc and lead sulfide ores, with the richest deposits located in the vicinity of the City of Picher. Mining in what became known as the Picher mining district began in the early 1900's and continued until about 1970. The water in the abandoned zinc and lead mines contains high concentrations of calcium, magnesium, bicarbonate, sulfate, fluoride, cadmium, copper, iron, lead, manganese, nickel, and zinc. Water from the abandoned mines is a potential source of contamination to the Roubidoux aquifer and to wells completed in the Roubidoux aquifer. Water samples were collected from wells completed in the Roubidoux aquifer in the Picher mining district and from wells outside the mining district to determine if 10 public supply wells in the mining district are contaminated. The chemical analyses indicate that at least 7 of the 10 public supply wells in the Picher mining district are contaminated by mine water. Application of the Mann-Whitney test indicated that the concentrations of some chemical constituents that are indicators of mine-water contamination are different in water samples from wells in the mining area as compared to wells outside the mining area. Application of the Wilcoxon signed-rank test showed that the concentrations of some chemical constituents that are indicators of mine-water contamination were higher in current (1992-93) data than in historic (1981-83) data, except for pH, which was lower in current than in historic data. pH and sulfate, alkalinity, bicarbonate, magnesium, iron, and tritium concentrations consistently

  2. Consumption of lead-shot cervid meat and blood lead concentrations in a group of adult Norwegians.

    Science.gov (United States)

    Meltzer, H M; Dahl, H; Brantsæter, A L; Birgisdottir, B E; Knutsen, H K; Bernhoft, A; Oftedal, B; Lande, U S; Alexander, J; Haugen, M; Ydersbond, T A

    2013-11-01

    Several recent investigations have reported high concentrations of lead in samples of minced cervid meat. This paper describes findings from a Norwegian study performed in 2012 among 147 adults with a wide range of cervid game consumption. The main aim was to assess whether high consumption of lead-shot cervid meat is associated with increased concentration of lead in blood. A second aim was to investigate to what extent factors apart from game consumption explain observed variability in blood lead levels. Median (5 and 95 percentile) blood concentration of lead was 16.6 µg/L (7.5 and 39 µg/L). An optimal multivariate linear regression model for log-transformed blood lead indicated that cervid game meat consumption once a month or more was associated with approximately 31% increase in blood lead concentrations. The increase seemed to be mostly associated with consumption of minced cervid meat, particularly purchased minced meat. However, many participants with high and long-lasting game meat intake had low blood lead concentrations. Cervid meat together with number of bullet shots per year, years with game consumption, self-assembly of bullets, wine consumption and smoking jointly accounted for approximately 25% of the variation in blood lead concentrations, while age and sex accounted for 27% of the variance. Blood lead concentrations increased approximately 18% per decade of age, and men had on average 30% higher blood lead concentrations than women. Hunters who assembled their own ammunition had 52% higher blood lead concentrations than persons not making ammunition. In conjunction with minced cervid meat, wine intake was significantly associated with increased blood lead. Our results indicate that hunting practices such as use of lead-based ammunition, self-assembling of lead containing bullets and inclusion of lead-contaminated meat for mincing to a large extent determine the exposure to lead from cervid game consumption. © 2013 Elsevier Inc. All rights

  3. Occupational exposure to lead--granulometric distribution of airborne lead in relation to risk assessment.

    Science.gov (United States)

    Carelli, G; Masci, O; Altieri, A; Castellino, N

    1999-07-01

    The amount of airborne lead absorbed by the body during occupational exposure depends not only on lead concentration in workplace air, but also on the granulometric distribution of the aerosol. The Occupational Safety and Health Administration (OSHA) set the lead Permissible Exposure Limit (PEL) at 50 micrograms/m3 on the basis of Bernard's model and a number of assumptions, including assumption "C", which predicts that the first 12.5 micrograms/m3 are made up of fine particles (aerodynamic diameter 1 micron. Occupational exposure to airborne lead at a concentration of 50 micrograms/m3 and a granulometric distribution calculated according to the above mentioned assumption, leads, in the model, to a mean blood level of 40 micrograms/dl. In the present study, we tested the validity of assumption "C" in the environmental air of a factory that manufactured crystal glassware containing 24% lead oxide. An 8-stage impactor was used to measure the particle size of airborne dust collected from personal and area samplings. Results indicate that, on the whole, assumption "C" cannot be considered valid in the work environment investigated in this study. As a result, lead absorption levels in exposed workers may be noticeably different from those predicted by the OSHA model. We therefore suggest that in order to make a correct evaluation of the risk of occupational exposure to lead, it is essential to integrate total airborne lead concentration with a measurement of the granulometric distribution of the aerosol.

  4. Lead-210, polonium-210, and stable lead in the food-chain lichen, reindeer and man

    International Nuclear Information System (INIS)

    Persson, B.R.

    1972-01-01

    The measurements of stable lead and the natural fallout radionuclides lead-210 and polonium-210 in communities of lichen (Cladonia alpestris) in central Sweden from 1961 to 1970 indicate a quite constant level. The average lead-210 content per unit area in lichen carpets was found to be 15 +- 2 nCi m -2 , the average lead-210 activity concentration 6.7 +- 0.9 nCi per kg dry weight and the lead-210 specific activity 630 +- 60 nCi per g of stable lead. The polonium-210/lead-210 activity ratio was about 0.9 +- 0.1. The vertical distribution of lead-210 in the lichen carpet showed a maximum concentration in the top layer. The distribution was similar during 1967 and 1968 but the low amount of precipitation during 1968 and 1969 disturbed the distribution pattern in 1969 and 1970. The transfer of lead-210, polonium-210 and stable lead through the food chain: lichen, reindeer, and man was characterized. The absorbed dose rate in Lapps due to polonium-210 was estimated to be about 6 to 8 mrad per year in gonads and 8 to 20 mrad per year in bone tissues. This is about ten percent of their entire absorbed dose contribution from all natural radiation sources. (U.S.)

  5. Involving Lead Users in Innovation

    DEFF Research Database (Denmark)

    Brem, Alexander; Bilgram, Volker; Gutstein, Adele

    2018-01-01

    Research on the lead user method has been conducted for more than thirty years and has shown that the method is more likely to generate breakthrough innovation than traditional market research tools. Based on a systematic literature review, this paper shows a detailed view on the broad variety...... of research on lead user characteristics, lead user processes, lead user identification and application, and success factors. The main challenge of the lead user method as identified in literature is the resource issue regarding time, manpower, and costs. Also, internal acceptance and the processing...... of the method have been spotted in literature, as well as the intellectual property protection issue. From the starting point of the initial lead user method process introduced by Lüthje and Herstatt (2004), results are integrated into a revisited view on the lead user method process. In addition, concrete...

  6. The relationship between environmental lead and blood lead in children : a study in environmental epidemiology

    NARCIS (Netherlands)

    Brunekreef, B.

    1985-01-01

    This study deals with the relationship between environmental lead and blood lead in children.
    Chapter 1 provides a summary of the environmental health aspects of lead. The occurrence of lead in the environment and in man is described; children are discussed as a population at

  7. Lead: Aspects of its ecology and environmental toxicity. [physiological effects of lead compound contamination of environment

    Science.gov (United States)

    Siegel, S. M.

    1973-01-01

    An analysis of lead toxicity in the Hawaiian environment was conducted. It was determined that lead enters the environment as an industrial contaminant resulting from the combustion of leaded gasoline. The amount of lead absorbed by the plants in various parts of the Hawaiian Islands is reported. The disposition of lead in the sediments of canals and yacht basins was investigated. The methods for conducting the surveys of lead content are described. Possible consequences of continued environmental pollution by burning leaded gasoline are discussed.

  8. Investigations on organolead compounds V. Lead---lead bond cleavage reactions of hexaphenyldilead

    NARCIS (Netherlands)

    Willemsens, L.C.; Kerk, G.J.M. van der

    1968-01-01

    It has been shown that a number of nucleophilic and weakly electrophilic reagents (organolithium and organomagnesium compounds, metallic lithium, potassium permanganate, sodium ethoxide, diaryl disulphides, sulphur, ozone, hypochlorous acid and iodine/iodide) selectively cleave the lead---lead bond

  9. Childhood lead poisoning investigations: evaluating a portable instrument for testing soil lead.

    Science.gov (United States)

    Reames, Ginger; Lance, Larrie L

    2002-04-01

    The Childhood Lead Poisoning Prevention Branch of the California Department of Health Services evaluated a portable X-ray fluorescence (XRF) instrument for use as a soil lead-testing tool during environmental investigations of lead-poisoned children's homes. A Niton XRF was used to test soil at 119 sampling locations in the yards of 11 San Francisco Bay Area houses. Niton XRF readings were highly correlated with laboratory results and met the study criteria for an acceptable screening method. The data suggest that the most health-protective and time-efficient approach to testing for soil lead above regulatory levels is to take either surface readings or readings of a test cup of soil prepared by grinding with a mortar and pestle. The advantage of the test cup method is that the test cup with soil may be submitted to a laboratory for confirmatory analysis.

  10. Lead Poisoning in Wild Birds

    Science.gov (United States)

    Lahner, Lesanna L.; Franson, J. Christian

    2009-01-01

    Lead in its various forms has been used for thousands of years, originally in cooking utensils and glazes and more recently in many industrial and commercial applications. However, lead is a potent, potentially deadly toxin that damages many organs in the body and can affect all animals, including humans. By the mid 1990s, lead had been removed from many products in the United States, such as paint and fuel, but it is still commonly used in ammunition for hunting upland game birds, small mammals, and large game animals, as well as in fishing tackle. Wild birds, such as mourning doves, bald eagles, California condors, and loons, can die from the ingestion of one lead shot, bullet fragment, or sinker. According to a recent study on loon mortality, nearly half of adult loons found sick or dead during the breeding season in New England were diagnosed with confirmed or suspected lead poisoning from ingestion of lead fishing weights. Recent regulations in some states have restricted the use of lead ammunition on certain upland game hunting areas, as well as lead fishing tackle in areas frequented by common loons and trumpeter swans. A variety of alternatives to lead are available for use in hunting, shooting sports, and fishing activities.

  11. Blood Lead Levels in Children and Environmental Lead Contamination in Miami Inner City, Florida

    Directory of Open Access Journals (Sweden)

    Theophile Niyonsenga

    2006-09-01

    Full Text Available Studies have shown that the environmental conditions of the home are important predictors of health, especially in low-income communities. Understanding the relationship between the environment and health is crucial in the management of certain diseases. One health outcome related to the home environment among urban, minority, and low-income children is childhood lead poisoning. The most common sources of lead exposure for children are lead paint in older, dilapidated housing and contaminated dust and soil produced by accumulated residue of leaded gasoline. Blood lead levels (BLL as low as 10 μg/dL in children are associated with impaired cognitive function, behavior difficulties, and reduced intelligence. Recently, it is suggested that the standard for intervention be lowered to BLL of 5 μg /dl. The objectives of our report were to assess the prevalence of lead poisoning among children under six years of age and to quantify and test the correlations between BLL in children and lead exposure levels in their environment. This cross-sectional analysis was restricted to 75 children under six years of age who lived in 6 zip code areas of inner city Miami. These locations exhibited unacceptably high levels of lead dust and soil in areas where children live and play. Using the 5 μg/dL as the cutoff point, the prevalence of lead poisoning among the study sample was 13.33%. The study revealed that lead levels in floor dust and window sill samples were positively and significantly correlated with BLL among children (p < 0.05. However, the correlations between BLL and the soil, air, and water samples were not significant. Based on this pilot study, a more comprehensive environmental study in surrounding inner city areas is warranted. Parental education on proper housecleaning techniques may also benefit those living in the high lead-exposed communities of inner city Miami.

  12. Neurophysiological effects of lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, I.; Wildt, K.; Gullberg, B.; Berlin, M.

    1983-10-01

    A series of neurophysiological variables was measured for men occupationally exposed to lead. The results were related to the degree of lead exposure and to the concentrations of lead and zinc protoporphyrin in blood. A small but significant correlation was observed between lead exposure and motor and sensory conduction velocities in the lower limbs, the conduction velocities of slow motor fibers in the upper limbs, and also sensory nerve action potentials. It is suggested that a neurophysiological examination should be considered in the surveillance of the health of lead workers.

  13. Environmental lead exposure among preschool children in Shanghai, China: blood lead levels and risk factors.

    Directory of Open Access Journals (Sweden)

    Jia Cao

    Full Text Available OBJECTIVE: To determine blood lead levels and to identify related risk factors among children in Shanghai; to explore the lead change trend of children after industrial transformation and to provide data for policy development to control environmental lead pollution in Shanghai. METHODS: A stratified-clustered-random sampling method was used. A tungsten atomizer absorption spectrophotometer was employed to determine blood lead levels. RESULTS: The arithmetic mean, geometric mean and median of blood lead levels of 0- to 6-year-old children from Shanghai were 22.49 µg/L, 19.65 µg/L and 19.5 µg/L, including 0.26% (6/2291 with concentrations ≥100 µg/L and 2.7% (61/2291 with concentrations ≥50 µg/L. Boys' levels (23.57 µg/L were greater than those of girls (21.2 µg/L. The blood lead levels increased with age. This survey showed that the Chongming district was the highest and Yangpu district was the lowest, this result is completely opposite with the earlier survey in Shanghai. Risk factors for lead contamination included housing environment, parents' education levels, social status, hobbies, and children's nutritional status. CONCLUSIONS: The blood lead levels of children in Shanghai were lower than the earlier data of Shanghai and those of published studies in China, but higher than the blood lead levels of developed countries. The blood lead levels of urban districts are higher than the central districts with the industrial transformation. Society and the government should take an active interest in childhood lead poisoning of urban areas.

  14. Behavior of active deposit of lead (Teisinger) in the Japanese free from occupational exposure to lead

    Energy Technology Data Exchange (ETDEWEB)

    Araki, S

    1973-12-01

    Intravenous infusion of calcium disodium ethylenediamine tetraacetate (CaEDTA) was given to 45 Japanese adults without occupational exposure to lead for 1 hr at a dosage of 20 mg/kg body weight in 250 ml of 5 percent glucose solution. The urinary excretion of lead was estimated for 24 hr before, and for 2 hr and 24 hr after the administration. The least variation of the lead content was recognized in the 24-hour urinary excretion after the injection of CaEDTA. No sexual difference was noted in the creatinine-corrected lead concentration. By multiple linear regression and correlation analyses, age was found to be significant in determining positively the lead level mobilized in 24-hour urine samples. Height was significant in determining positively the spontaneous 24-hour urinary lead excretion. Certain significant correlations existed among lead in blood, delta-aminolevulinic acid dehydratase in erythrocytes, delta-aminolevulinic acid in urine, coproporphyrin in urine, lead in urine, and lead mobilized by CaEDTA. The existence of active body burden of lead was suggested in human subjects under usual urban conditions where the total ambient lead concentration averaged 1.7 micrograms/cm m of air. Based on a few assumptions, it was calculated that about 3 micrograms of lead was retained on the average per day by a Japanese adult. Daily retention of lead by Japanese adults was formularized as lead in micrograms equals a constant (K) times daily creatinine excretion in grams, where K is 1.77 in men and 2.73 in women. (Air Pollut. Abstr.)

  15. Environmental lead hazard to children.

    Science.gov (United States)

    Mittal, S K

    1992-01-01

    Clinically evident lead poisoning is rare in Indian children but is more common than in adults. In children, lead poisoning may appear as fever, seizures, anemia, or abdominal pain, while in adults it is more likely to manifest as chronic minor peripheral neuropathy or gum pigmentation. Children with acute lead poisoning can be treated with chelators such as EDTA and BAL, but many are left with permanent brain damage. The most common sources of acute lead poisoning in Indian children are inhalation of fumes from burned car batteries, ingestion of flaking paint, consuming food cooked in cheap aluminum or brass utensils, and eating contaminated soil. The sources of chronic lead poisoning are water from lead pipes and fumes from industrial or automotive exhaust. Another common source in India is application of "kajjal" to children's eyes. Sources of lead in Western countries, such as drinking water, canned food, residential paint, automotive fuel, and ambient air quality, are regulated by law. None of these are regulated in India.

  16. Levels and source apportionment of children's lead exposure: Could urinary lead be used to identify the levels and sources of children's lead pollution?

    International Nuclear Information System (INIS)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-01-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as 207 Pb/ 206 Pb, 208 Pb/ 206 Pb and 204 Pb/ 206 Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. - Highlights: • Pb isotopes of environmental media and children's blood and urine were analyzed. • Pb exposure and pollution source were studied in lead-acid battery and coking areas. • Pb isotope ratios in blood and urine were similar to those of food, water and PM. • Urine Pb level may not be used as a proxy for indicating the lead levels in blood. • Urine Pb isotope ratios is an alternative to identify source and exposure pathways. - Urinary lead is not a preferable proxy to estimate blood lead level, but urinary lead isotope ratios could be an alternative for identifying the sources of lead exposure in children

  17. Neurological aspects of lead intoxication

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, H

    1980-05-08

    This study gives a survey over the medical and scientific literature on lead intoxications, which were published until 1979. Neurologic aspects are of particular interest. At present dramatic cases of lead intoxications occur only rarely. However, there are numerous studies about cases of chronical, partly subclinical intoxications. This chronical type of lead intoxication can become manifest clinically as relatively vague symptoms, for example vertigos, insomnia, headaches and weakness. Contrary to this, serious encephalopathies, even with fatal outcome, and polyneuropathies with typical paresis of the radial nerve are preferably observed in acute lead intoxications. Besides the numerous sources of intoxication, also the different opinions found in literature are discussed, concerning the effects of lead on the human body. The fact that there are differing opinions about the limiting value of the blood-lead level at which intoxication symptoms have to be expected, becomes apparent when the determined blood-lead level values are compared and evaluated. Besides the description of general intoxication effects, the discussion of the neurologic aspects found in literature - not only those concerning the central, but also the peripheral system - are preferably concerned. Reports about neuropsychical alterations due to lead exposure, which are mainly found in children, supplement the numerous descriptions of the macroscopic and microscopic alterations of the nervous system provoked by lead. Finally the therapeutic and prophylactic measures given in the literature are discussed.

  18. Optical properties of calcium barium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Heine, Urs; Betzler, Klaus [Department of Physics, University of Osnabrueck (Germany); Burianek, Manfred; Muehlberg, Manfred [Institute of Crystallography, University of Cologne (Germany)

    2010-07-01

    We report on optical measurements on the novel tungsten bronze type calcium barium niobate. [001]-oriented transparent and colorless single crystals were grown by the Czochralski method with dimensions of 12 mm in diameter and about 80 mm in length. With its relatively high Curie temperature of about 538 K for the congruently melting composition of 28.1 mole% calcium and its high nonlinear coefficients, CBN is a promising material for future applications. Recent experiments revealed, that the application of an external electric field of several kV/cm to CBN at room temperature leads to an increasing opacity of the sample. This might be a drawback considering the future usability of CBN in optical systems. We present investigations on the transmittance behaviour of CBN under external electric fields, demonstrating the erasement of the clouding without affecting the polarization. Experiments have been performed at temperatures ranging from room temperature to approximately 480 K. When heating up the sample, its colorless appearance changes to a light yellow, which can be attributed to a shift of the band edge to longer wavelengths with increasing temperature. To further investigate the transmittance properties of CBN, measurements of the band edge under various temperatures up to the ferroelectric phase transition have been performed.

  19. Monetary benefits of preventing childhood lead poisoning with lead-safe window replacement.

    Science.gov (United States)

    Nevin, Rick; Jacobs, David E; Berg, Michael; Cohen, Jonathan

    2008-03-01

    Previous estimates of childhood lead poisoning prevention benefits have quantified the present value of some health benefits, but not the costs of lead paint hazard control or the benefits associated with housing and energy markets. Because older housing with lead paint constitutes the main exposure source today in the US, we quantify health benefits, costs, market value benefits, energy savings, and net economic benefits of lead-safe window replacement (which includes paint stabilization and other measures). The benefit per resident child from improved lifetime earnings alone is $21,195 in pre-1940 housing and $8685 in 1940-59 housing (in 2005 dollars). Annual energy savings are $130-486 per housing unit, with or without young resident children, with an associated increase in housing market value of $5900-14,300 per housing unit, depending on home size and number of windows replaced. Net benefits are $4490-5,629 for each housing unit built before 1940, and $491-1629 for each unit built from 1940-1959, depending on home size and number of windows replaced. Lead-safe window replacement in all pre-1960 US housing would yield net benefits of at least $67 billion, which does not include many other benefits. These other benefits, which are shown in this paper, include avoided Attention Deficit Hyperactivity Disorder, other medical costs of childhood lead exposure, avoided special education, and reduced crime and juvenile delinquency in later life. In addition, such a window replacement effort would reduce peak demand for electricity, carbon emissions from power plants, and associated long-term costs of climate change.

  20. Functional engineering of perovskite nanosheets. Impact of lead substitution on exfoliation in the solid solution RbCa{sub 2-x}Pb{sub x}Nb{sub 3}O{sub 10}

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, Christian; Lotsch, Bettina V. [Max Planck Institute for Solid State Research, Stuttgart (Germany); Department of Chemistry, University of Munich (LMU), Munich (Germany); Nanosystems Initiative Munich (NIM) and Center for Nanoscience (CeNS), Munich (Germany); Dennenwaldt, Teresa [Max-Planck-Institut fuer Eisenforschung GmbH, Duesseldorf (Germany); Ecole Polytechnique Federale de Lausanne (Switzerland); Weber, Daniel; Duppel, Viola; Kamella, Claudia; Tuffy, Brian; Moudrakovski, Igor [Max Planck Institute for Solid State Research, Stuttgart (Germany); Podjaski, Filip [Max Planck Institute for Solid State Research, Stuttgart (Germany); Ecole Polytechnique Federale de Lausanne (Switzerland); Scheu, Christina [Max-Planck-Institut fuer Eisenforschung GmbH, Duesseldorf (Germany)

    2017-11-17

    Tuning the chemical composition and structure for targeted functionality in two-dimensional (2D) nanosheets has become a major objective in the rapidly growing area of 2D materials. In the context of photocatalysis, both miniaturization and extending the light absorption of UV active photocatalysts are major assets. Here, we investigate the solid solution between two photocatalytic systems known from literature to evolve H{sub 2} from water/methanol under UV - RbCa{sub 2}Nb{sub 3}O{sub 10} (E{sub g} = 3.7 eV) - and visible light irradiation - RbPb{sub 2}Nb{sub 3}O{sub 10} (E{sub g} = 3.0 eV) - by synthesizing hypothetical RbCa{sub 2-x}Pb{sub x}Nb{sub 3}O{sub 10}. While the calcium niobate can easily be exfoliated into individual nanosheets via cation-proton exchange and subsequent treatment with tetra-n-butylammonium hydroxide (TBAOH), the lead niobate barely yields nanosheets. Spectroscopic and microscopic analysis suggest that this is caused by volatilization of Pb during synthesis, leading to a local 3D linkage of RbPb{sub 2}Nb{sub 3}O{sub 10} perovskite units with Pb deficient units. On the one hand, this linkage progressively prevents exfoliation along with an increasing Pb content. On the other hand, introducing Pb into the perovskite blocks successively leads to bandgap narrowing, thus gradually enhancing the light harvesting capability of the solid solution. Finding a compromise between this narrowing of the bandgap and the possibility of exfoliation, visible light sensitized nanosheets can be engineered in good yield for an initial molar ratio of Ca:Pb ≥ 1:1. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Characterization of sources of lead in the urban air of Asia using ratios of stable lead isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, H.; Furuta, N.; Fujii, T.; Ambe, Y.; Sakamoto, K.; Hashimoto, Y. (National Institute of Environmental Studies, Tsukuba (Japan). Environmental Chemistry Division)

    1993-07-01

    Airborne particulate matter was collected at urban sites in six Asian countries (Japan, South Korea, China, Thailand, Sri Lanka, and Indonesia), and the stable lead isotope ratios were measured. Some source-related materials, such as coal and leaded gasoline, were also analyzed and compared to the ratios observed in airborne lead. Airborne lead isotope ratios differed considerably from each other, and these differences corresponded to differences in the regional source of lead. Leaded gasoline was still the primary source of lead in some cities in Asia, and the lead isotope ratios were strongly influenced by those of leaded gasoline. In Chinese and Korean cities, however, the considerable effect from coal combustion and industrial activity was also observed in their isotope ratios, despite leaded gasoline use. On the other hand, only refuse incineration was a possible single source of lead in Japanese air from the view of lead isotope ratios. 49 refs., 13 figs., 3 tabs.

  2. Australian atmospheric lead deposition reconstructed using lead concentrations and isotopic compositions of archival lichen and fungi

    International Nuclear Information System (INIS)

    Wu, Liqin; Taylor, Mark Patrick; Handley, Heather K.; Wu, Michael

    2016-01-01

    Lead concentrations and their isotopic compositions were measured in lichen genera Cladonia and Usnea and fungi genus Trametes from the Greater Sydney region (New South Wales, Australia) that had been collected and archived over the past 120 years. The median lead concentrations were elevated in lichens and fungi prior to the introduction of leaded petrol (Cladonia 12.5 mg/kg; Usnea 15.6 mg/kg; Trametes 1.85 mg/kg) corresponding to early industrial development. During the period of leaded petrol use in Australian automobiles from 1932 to 2002, total median lead concentrations rose: Cladonia 18.8 mg/kg; Usnea 21.5 mg/kg; Trametes 4.3 mg/kg. Following the cessation of leaded petrol use, median total lead concentrations decreased sharply in the 2000s: Cladonia 4.8 mg/kg; Usnea 1.7 mg/kg. The lichen and fungi isotopic compositions reveal a significant decrease in "2"0"6Pb/"2"0"7Pb ratios from the end of 19th century to the 1970s. The following decades were characterised by lower allowable levels of lead additive in fuel and the introduction of unleaded petrol in 1985. The environmental response to these regulatory changes was that lichen and fungi "2"0"6Pb/"2"0"7Pb ratios increased, particularly from 1995 onwards. Although the lead isotope ratios of lichens continued to increase in the 2000s they do not return to pre-leaded petrol values. This demonstrates that historic leaded petrol emissions, inter alia other sources, remain a persistent source of anthropogenic contamination in the Greater Sydney region. - Highlights: • Total lead and isotopic composition can be measured in historic lichen and fungi. • Historic lichen and fungi samples can distinguish polluted and unpolluted areas. • Former leaded petrol depositions remain a significant environmental contaminant. - Analysis of a 120-year record of lichens and fungi from the Greater Sydney basin reveal marked shifts in total lead concentrations and lead isotope ratios in response to geogenic inputs

  3. Current leads for superconducting magnets

    International Nuclear Information System (INIS)

    Ishibashi, Kenji

    1989-01-01

    Current leads for superconducting magnets have been studied since 1960's. The technology of current leads may seem to have been established both in theory and experiment before the middle of 1970's. Nevertheless, a wide variety of superconducting magnets have been introduced in the last 15 years, and the demands for special current leads have increased in accordance to the variety. A steady advance has been made in the design theory and fabrication of current leads. This paper describes the recent current lead technology regarding the design theory, safety in accidents, and high current capability. (author)

  4. Assessment of the body burden of chelatable lead: a model and its application to lead workers

    Energy Technology Data Exchange (ETDEWEB)

    Araki, S.; Ushio, K.

    1982-05-01

    A hypothetical model was introduced to estimate the body burden of chelatable lead from the mobilisation yield of lead by calcium disodium ethylenediamine tetra-acetate. It was estimated that, on average, 14 and 19% of the body burden was mobilized into the urine during the 24 hours after an injection of 53.4 mumol and 107 mumol CaEDTA per kg bodyweight, respectively. The body burden of chelatable lead ranged from 4 mumol to 120 mumol in lead workers with blood lead concentrations of 0.3-2.9 mumol/kg. There were linear relationships between blood lead concentrations and body burden of chelatable lead on a log scale.

  5. Lead contamination of inexpensive plastic jewelry

    Energy Technology Data Exchange (ETDEWEB)

    Yost, Jamie L. [Department of Chemistry, Ashland University, Ashland, Ohio (United States); Weidenhamer, Jeffrey D. [Department of Chemistry, Ashland University, Ashland, Ohio (United States)], E-mail: jweiden@ashland.edu

    2008-04-15

    The neurological hazards of lead to children are well-known. As a result of recent documented cases of lead poisoning, regulatory attention in the United States has focused on the lead content of children's metal jewelry. By contrast, little is known about the possible hazards of plastic jewelry items. The objective of this study was to determine whether inexpensive plastic jewelry is a possible source of toxic lead for children. Samples of more than 100 inexpensive plastic jewelry items were analyzed for lead content. Beads were screened by soaking in 1 M nitric acid. Nine items found to release more than 30 {mu}g of lead per bead were further tested for accessible lead, and scrapings of the bead coatings were analyzed for total lead content. The maximum accessible lead found was 49 {mu}g per bead, which is below the current US Consumer Product Safety Commission limit of 175 {mu}g. However, when the number of beads in each item was taken into account, six of the nine leaded samples contained more than 175 {mu}g accessible lead per item. The lead in these items appears to be associated with lead-based paints used to produce glossy coatings on imitation pearls and similar items. Coatings obtained by scraping individual beads contained 3.5-23% lead, which far exceeds the US regulatory limit of 0.06% lead in paints on items intended for children. Our results demonstrate that plastic jewelry items merit the attention of public health and consumer protection agencies seeking to limit the exposure of children to lead.

  6. Lead contamination of inexpensive plastic jewelry

    International Nuclear Information System (INIS)

    Yost, Jamie L.; Weidenhamer, Jeffrey D.

    2008-01-01

    The neurological hazards of lead to children are well-known. As a result of recent documented cases of lead poisoning, regulatory attention in the United States has focused on the lead content of children's metal jewelry. By contrast, little is known about the possible hazards of plastic jewelry items. The objective of this study was to determine whether inexpensive plastic jewelry is a possible source of toxic lead for children. Samples of more than 100 inexpensive plastic jewelry items were analyzed for lead content. Beads were screened by soaking in 1 M nitric acid. Nine items found to release more than 30 μg of lead per bead were further tested for accessible lead, and scrapings of the bead coatings were analyzed for total lead content. The maximum accessible lead found was 49 μg per bead, which is below the current US Consumer Product Safety Commission limit of 175 μg. However, when the number of beads in each item was taken into account, six of the nine leaded samples contained more than 175 μg accessible lead per item. The lead in these items appears to be associated with lead-based paints used to produce glossy coatings on imitation pearls and similar items. Coatings obtained by scraping individual beads contained 3.5-23% lead, which far exceeds the US regulatory limit of 0.06% lead in paints on items intended for children. Our results demonstrate that plastic jewelry items merit the attention of public health and consumer protection agencies seeking to limit the exposure of children to lead

  7. Lead transfer in maternal milk, and the absorption, retention, distribution and excretion of lead in suckling mice

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Charles Arthur [Univ. of Rochester, NY (United States). Dept. of Radiation Biology and Biophysics

    1980-01-01

    Suckling mice were found to absorb and retain a greater fraction of an oral lead dose than did adult mice. Pinocytotic activity and lead uptake (in vivo) were found to be greatest in the distal small intestinal tissue. Cortisone pretreatment results in precocious cessation of pinocytotic activity in the intestine of suckling mice. Cortisone pretreatment of adult mice had no effect on whole body lead retention or intestinal tissue content of lead following an oral dose. The data indicate that the distal small intestine is the site of active pinocytosis of lead, and that pinocytosis is the major mechanism involved in lead absorption in suckling mice. Developmental differences were also observed in the percentage of lead retained in the whole body. Both groups exhibited dose-independent lead retention, indicating a first-order absorption process for each age group. Lead distribution and elimination from organs also differed between suckling and adult mice. Developmental differences were observed in organ lead concentration for kidneys and brain following oral doses. Relative distribution of lead to the brains of suckling mice were greater than to adult brains. Whole body and bone lead elimination rates were reduced in suckling compared to adult mice. Brain lead elimination rates did not differ in suckling and adult mice. A lactating mouse model was developed to study lead transfer to suckling offspring. Lead was transferred in milk to suckling offspring from mothers which had previously ingested lead in the drinking water. Relative lead transfer to suckled offspring during lactation greatly exceeded transfer to fetuses during gestation. Lactation resulted in an increased rate of maternal lead elimination. Lead concentration in milk exceeded plasma concentration by a factor of approximately 25. (ERB)

  8. Blood lead levels among rural Thai children exposed to lead-acid batteries from solar energy conversion systems.

    Science.gov (United States)

    Swaddiwudhipong, Witaya; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Sanreun, Cherd

    2013-11-01

    We evaluate blood lead levels among Thai children to determine if exposure to lead-acid batteries is associated with elevated blood lead levels (EBLL). We screened 254 children aged 1-14 years old from 2 rural Thai villages for blood lead levels. We also screened 18 of 92 houses in these 2 villages for the presence of environmental lead. The overall prevalence of EBLL (> or = 10 microg/dl) was 43.3% and the mean lead level among study subjects was 9.8 +/- 5.1 microg/dl. The blood lead levels significantly decreased with increasing age. Fifty point eight percent of children who lived in a house with vented lead-acid batteries had EBLL while 23.3% of children who lived in a house without vented lead-acid batteries had EBLL. Multiple logistic regression analysis revealed a significant positive association between the presence of vented lead-acid batteries and EBLL, after adjusting for other variables. Forty-two point nine percent of house floor dust samples collected near the batteries had elevated lead levels, 7.1% of house floor dust samples collected from other areas in the house had elevated lead levels and 0% of the house floor dust samples collected in houses without vented lead-acid batteries had elevated lead levels. In the sampled houses with vented lead-acid batteries, lead contamination was found in the drinking-water kept in household containers, but not in the tap water or other village sources of water. Improper care and placement of vented lead-acid batteries can result in lead contamination in the home environment causing EBLL in exposed children.

  9. Spent lead-acid battery recycling in China - A review and sustainable analyses on mass flow of lead.

    Science.gov (United States)

    Sun, Zhi; Cao, Hongbin; Zhang, Xihua; Lin, Xiao; Zheng, Wenwen; Cao, Guoqing; Sun, Yong; Zhang, Yi

    2017-06-01

    Lead is classified to be one of the top heavy metal pollutants in China. The corresponding environmental issues especially during the management of spent lead-acid battery have already caused significant public awareness and concern. This research gives a brief overview on the recycling situation based on an investigation of the lead industry in China and also the development of technologies for spent lead-acid batteries. The main principles and research focuses of different technologies including pyrometallurgy, hydrometallurgy and greener technologies are summarized and compared. Subsequently, the circulability of lead based on the entire life cycle analyses of lead-acid battery is calculated. By considering different recycling schemes, the recycling situation of spent lead-acid battery in China can be understood semi-quantitatively. According to this research, 30% of the primary lead production can be shut down that the lead production can still ensure consecutive life cycle operation of lead-acid battery, if proper management of the spent lead-acid battery is implemented according to current lead industry situation in China. This research provides a methodology on the view of lead circulability in the whole life cycle of a specific product and is aiming to contribute more quantitative guidelines for efficient organization of lead industry in China. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Childhood lead exposure and uptake in teeth in the Cleveland area during the era of leaded gasoline

    International Nuclear Information System (INIS)

    Robbins, Norman; Zhang, Zhong-Fa; Sun, Jiayang; Ketterer, Michael E.; Lalumandier, James A.; Shulze, Richard A.

    2010-01-01

    Childhood uptake of lead from exposure to atmospheric leaded gasoline in the United States has been studied using mainly blood lead levels. Since reliable blood lead techniques were used only after the peak use of leaded gasoline, the prior exposure history is unclear. The well-documented decline in blood lead levels after the mid-1970s could represent the continuation of a historic steady decline in exposure from many sources. Alternatively, the post-1970s decline might represent the declining phase of a unimodal rise and fall corresponding closely to usage of leaded gasoline. To assess these possibilities, lead concentration and 207Pb/206Pb isotope ratios were measured in the enamel of permanent molar teeth formed between 1936 and 1993 in mainly African-American donors who grew up in the Cleveland area. Tooth enamel preserves the lead concentration and isotope ratio that prevails during tooth formation. Historical trends in enamel lead concentration were significantly correlated with surrogates of atmospheric lead exposure: lead in sediments of two dated Lake Erie cores, and lead consumed in gasoline. About two-thirds of the total lead uptake into enamel in this period was attributable to leaded gasoline, and the remainder to other sources (e.g. paint). Enamel 207Pb/206Pb isotope ratios were similar to those of one lake sediment. Multivariate analysis revealed significant correlation in neighborhoods with higher levels of traffic, and including lake sediment data, accounted for 53% of the variation in enamel lead levels. Enamel lead concentration was highly correlated with reported African-American childhood blood levels. The extrapolated peak level of 48 μg/dL (range 40 to 63) is associated with clinical and behavioral impairments, which may have implications for adults who were children during the peak gasoline lead exposure. In sum, leaded gasoline emission was the predominant source of lead exposure of African-American Cleveland children during the latter

  11. Ingestion of lead from ammunition and lead concentrations in white-tailed sea eagles (Haliaeetus albicilla) in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Helander, B., E-mail: bjorn.helander@nrm.se [Department of Contaminant Research, Swedish Museum of Natural History, Box 50007, SE-104 05 Stockholm (Sweden); Axelsson, J., E-mail: jeanette.axelsson@hgen.slu.se [Department of Environmental Toxicology, Evolutionary Biology Centre, Uppsala University, SE-752 36 Uppsala (Sweden); Borg, H., E-mail: hans.borg@itm.su.se [Department of Applied Environmental Science/ITM, Stockholm University, SE-106 91 Stockholm (Sweden); Holm, K. [Department of Applied Environmental Science/ITM, Stockholm University, SE-106 91 Stockholm (Sweden); Bignert, A., E-mail: anders.bignert@nrm.se [Department of Contaminant Research, Swedish Museum of Natural History, Box 50007, SE-104 05 Stockholm (Sweden)

    2009-10-15

    In this study we show for the first time that lead poisoning from ammunition is a significant mortality factor for white-tailed sea eagle (WSE) (Haliaeetus albicilla) in Sweden. We analyzed 118 WSEs collected between 1981 and 2004 from which both liver and kidney samples could be taken. A total of 22% of all eagles examined had elevated (> 6 {mu}g/g d.w.) lead concentrations, indicating exposure to leaded ammunition, and 14% of the individuals had either liver or kidney lead concentrations diagnostic of lethal lead poisoning (> 20 {mu}g/g d.w.). Lead concentrations in liver and kidney were significantly correlated. In individuals with lead levels < 6 {mu}g/g, concentrations were significantly higher in kidney than in liver; in individuals with lead levels > 20 {mu}g/g, concentrations were significantly higher in liver. The lead isotope ratios indicate that the source of lead in individuals with lethal concentrations is different from that of individuals exhibiting background concentrations of lead (< 6 {mu}g/g d.w.) There were no significant sex or age differences in lead concentrations. A study from the Baltic reported in principle no biomagnification of lead, but background lead concentrations in WSE liver in this study were still four to > 10 times higher than concentrations reported for Baltic fish from the same time period. In contrast to other biota there was no decrease in lead concentrations in WSE over the study period. The proportion of lead poisoned WSE remained unchanged over the study period, including two years after a partial ban of lead shot was enforced in 2002 for shallow wetlands. The use of lead in ammunition poses a threat to all raptors potentially feeding on shot game or offal. The removal of offal from shot game and alternatives to leaded ammunition needs to be implemented in order to prevent mortality from lead in raptors and scavengers.

  12. Blood lead levels and risk factors for lead poisoning among children in Jakarta, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Albalak, Rachel; Noonan, Gary; Buchanan, Sharunda; Flanders, W. Dana; Gotway-Crawford, Carol; Blumenthal, Wendy; Curtis, Gerald; McGeehin, Michael A. [Division of Environmental Hazards and Health Effects, National Center for Environmental Health, Centers for Disease Control and Prevention, 1600 Clifton Rd. Mailstop E-19, Atlanta, GA 30333 (United States); Kim, Dennis; Tan, Regina [Epidemic Intelligence Service, Epidemiology Program Office, Centers for Disease Control and Prevention, 1600 Clifton Rd. Mailstop D-18, Atlanta, GA 30333 (United States); Jones, Robert L. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 1600 Clifton Rd. Mailstop F-18, Atlanta, GA 30333 (United States); Sulaiman, Rini [Swisscontact, Jl. Wijaya XII No. 44, Jakarta (Indonesia) 12160

    2003-01-01

    The phase-out of leaded gasoline began in Jakarta, Indonesia on July 1, 2001. We evaluated mean blood lead levels (BLLs) and the prevalence of elevated BLLs of Jakarta school children and assessed risk factors for lead exposure in these children before the beginning of the phase-out activities. The study involved a population-based, cross-sectional blood lead survey that included capillary blood lead sampling and a brief questionnaire on risk factors for lead poisoning. A cluster survey design was used. Forty clusters, defined as primary schools in Jakarta, and 15 2nd- and 3rd-grade children in each cluster were randomly selected for participation in the study. The average age of children in this study was 8.6 years (range 6-12) and the geometric mean BLL of the children was 8.6 {mu}g/dl (median: 8.6 {mu}g/dl; range: 2.6-24.1 {mu}g/dl) (n=397). Thirty-five percent of children had BLLs {>=}10 {mu}g/dl and 2.4% had BLLs {>=}20 {mu}g/dl. Approximately one-fourth of children had BLLs 10-14.9 {mu}g/dl. In multivariate models, level of education of the child's primary caregiver, water collection method, home varnishing and occupational recycling of metals, other than lead, by a family member were predictors of log BLLs after adjustment for age and sex. BLLs of children who lived near a highway or major intersection were significantly higher than those of children who lived near a street with little or no traffic when level of education was not included in the model. Water collection method was a significant predictor of BLLs {>=}10 {mu}g/dl after adjustment for age and sex. BLLs in children in this study were moderately high and consistent with BLLs of children in other countries where leaded gasoline is used. With the phase-out of leaded gasoline, BLLs of children in Jakarta are expected to rapidly decline as they have in other countries that have phased lead out of gasoline.

  13. Some Interesting Events from Lead-Lead Collisions in ATLAS at the LHC (individual captions in abstract)

    CERN Multimedia

    The ATLAS Experiment, ATLAS, First collisions, Splash events

    2010-01-01

    Image Captions CERN-EX-1011310 01 -- Event display of a highly asymmetric dijet event, with one jet with ET > 100 GeV and no evident recoiling jet, recorded by ATLAS in LHC lead-lead collisions. CERN-EX-1011310 02 -- Event display of a highly asymmetric dijet event, with one jet with ET > 100 GeV and no evident recoiling jet, recorded by ATLAS in LHC lead-lead collisions. CERN-EX-1011310 03 -- Event display of a highly asymmetric dijet event, with one jet with ET > 100 GeV and no evident recoiling jet, recorded by ATLAS in LHC lead-lead collisions. CERN-EX-1011310 04 -- LHC lead-lead collisions recorded by ATLAS with a candidate Z to μ+μ- decay. The two muons shown in purple are the candidates to originate from the Z decay. The transverse momenta of these two muons are 44 and 45 GeV, and the invariant mass of the dimuon system is 93 GeV. CERN-EX-1011310 05 -- LHC lead-lead collisions recorded by ATLAS with a candidate Z to μ+μ- decay. The two muons shown in red are the candidates to originate from the...

  14. Small for Gestational Age and Magnesium: Intrauterine magnesium deficiency may induce metabolic syndrome in later life

    Directory of Open Access Journals (Sweden)

    Junji Takaya

    2015-12-01

    Full Text Available Magnesium deficiency during pregnancy as a result of insufficient or low intake of magnesium is common in developing and developed countries. Previous reports have shown that intracellular magnesium of cord blood platelets is lower among small for gestational age (SGA groups than that of appropriate for gestational age (AGA groups, suggesting that intrauterine magnesium deficiency may result in SGA. Additionally, the risk of adult-onset diseases such as insulin resistance syndrome is greater among children whose mothers were malnourished during pregnancy, and who consequently had a low birth weight. In a number of animal models, poor nutrition during pregnancy leads to offspring that exhibit pathophysiological changes similar to human diseases. The offspring of pregnant rats fed a magensium restricted diet have developed hypermethylation in the hepatic 11β-hydroxysteroid dehydrogenase-2 promoter. These findings indicate that maternal magnesium deficiencies during pregnancy influence regulation of non-imprinted genes by altering the epigenetic regulation of gene expression, thereby inducing different metabolic phenotypes. Magnesium deficiency during pregnancy may be responsible for not only maternal and fetal nutritional problems, but also lifelong consequences that affect the offspring throughout their life. Epidemiological, clinical, and basic research on the effects of magnesium deficiency now indicates underlying mechanisms, especially epigenetic processes.

  15. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  16. Radiation shielding lead shield

    International Nuclear Information System (INIS)

    Dei, Shoichi.

    1991-01-01

    The present invention concerns lead shields for radiation shielding. Shield boxes are disposed so as to surround a pipeline through which radioactive liquids, mists or like other objects are passed. Flanges are formed to each of the end edges of the shield boxes and the shield boxes are connected to each other by the flanges. Upon installation, empty shield boxes not charged with lead particles and iron plate shields are secured at first at the periphery of the pipeline. Then, lead particles are charged into the shield boxes. This attains a state as if lead plate corresponding to the depth of the box is disposed. Accordingly, operations for installation, dismantling and restoration can be conducted in an empty state with reduced weight to facilitate the operations. (I.S.)

  17. Presence of lead in opium.

    Science.gov (United States)

    Aghaee-Afshar, Mahmoud; Khazaeli, Payam; Behnam, Behzad; Rezazadehkermani, Mohammad; Ashraf-Ganjooei, Narges

    2008-09-01

    Opium addiction is a common form of addiction in Middle East countries such as Iran. Recently several reports suggested some kinds of pathologic findings such as abdominal pain, nephropathy, and anemia in opium addict patients. Such pathologic findings suggest lead poisoning in the patients. In this study, the concentration of lead in 10 opium samples was evaluated. The mean concentration of lead in the opium samples was 1.88 ppm. This may explain some of the pathologic findings found in addict patients. The authors would suggest further investigations to evaluate the lead concentration in opium addicts' sera and also routine screening for lead poisoning in opium addict patients.

  18. Ingestion of lead from ammunition and lead concentrations in white-tailed sea eagles (Haliaeetus albicilla) in Sweden

    International Nuclear Information System (INIS)

    Helander, B.; Axelsson, J.; Borg, H.; Holm, K.; Bignert, A.

    2009-01-01

    In this study we show for the first time that lead poisoning from ammunition is a significant mortality factor for white-tailed sea eagle (WSE) (Haliaeetus albicilla) in Sweden. We analyzed 118 WSEs collected between 1981 and 2004 from which both liver and kidney samples could be taken. A total of 22% of all eagles examined had elevated (> 6 μg/g d.w.) lead concentrations, indicating exposure to leaded ammunition, and 14% of the individuals had either liver or kidney lead concentrations diagnostic of lethal lead poisoning (> 20 μg/g d.w.). Lead concentrations in liver and kidney were significantly correlated. In individuals with lead levels 20 μg/g, concentrations were significantly higher in liver. The lead isotope ratios indicate that the source of lead in individuals with lethal concentrations is different from that of individuals exhibiting background concentrations of lead ( 10 times higher than concentrations reported for Baltic fish from the same time period. In contrast to other biota there was no decrease in lead concentrations in WSE over the study period. The proportion of lead poisoned WSE remained unchanged over the study period, including two years after a partial ban of lead shot was enforced in 2002 for shallow wetlands. The use of lead in ammunition poses a threat to all raptors potentially feeding on shot game or offal. The removal of offal from shot game and alternatives to leaded ammunition needs to be implemented in order to prevent mortality from lead in raptors and scavengers.

  19. Lead-contaminated health food. Association with lead poisoning and leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Crosby, W.H.

    1977-06-13

    A doctor prescribed a dietary supplement prepared from powdered animal bone for a young woman with dysmenorrhea. Severe lead poisoning developed while she was taking the powder, which was shown to be contaminated with lead. The diagnosis eluded more than 20 physicians and was finally made by the patient herself. The Food and Drug Administration, informed of the contamination, declined to take action, stating that a food supplement is neither a food nor a drug and, besides, there are no maximal limits for heavy-metal contamination of foods and drugs.

  20. Lead poisoning in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M R; Lewis, G

    1963-08-03

    Within a short period, 14 cases of lead poisoning in the dogs have been encountered. A detailed record appears justified as no published reference can be found to this condition occurring in Britain and because reports from other countries stress the similarity of the clinical manifestations of lead poisoning to those of the common infections of the dog. Five of the 14 clinical cases of lead poisoning are described. The available literature is reviewed and the diagnosis and significance of the condition discussed. 19 references, 2 tables.

  1. Irradiation-induced modification of the material parameters in magnesium-doped lithium niobate; Bestrahlungsinduzierte Modifikation der Materialparameter in Magnesiumdotiertem Lithiumniobat

    Energy Technology Data Exchange (ETDEWEB)

    Jentjens, Lena

    2010-07-01

    In the framework of this thesis the material properties of lithium niobate are directedly influenced by the irradiation with {sup 3}He ions with an energy of 40 MeV. In the first part the irradiation-induced material changes are intensively studied. Long-time stable changes of the refractive index are measured in the range of up to 6.10{sup -3}, which depend on the radiation dose and exhibit until now no saturation behaviour. Accompanied is this change by an also dose-dependent deformation as well as a brownish change of color of the crystals. Furthermore a by several orders of magnitude increased electrical dark- and photoconductivity, which depends on the ion dose and exhibits until now also no saturation behaviour. An effect independent on the ion dose is the reduction of the coercive field strength by about 10%. Furthermore it was stated the quantity of the effects not only depends on the absolute dose, but also on the irradiation direction in view of the crystallographic c-axis. The second part of this thesis deals with the generation of microscopic structures in lithium niobate. By an ion microbeam respectively a shiftable slit aperture the fabrication of refractive-index gratings is pursued. Grating with periodicity lengths in the range of 12-160 {mu}m could until now be detected and promise in comparison with photorefractive gratings the advance of larger stability.

  2. Microwave-induced electrostatic etching: generation of highly reactive magnesium for application in Grignard reagent formation.

    Science.gov (United States)

    van de Kruijs, Bastiaan H P; Dressen, Mark H C L; Meuldijk, Jan; Vekemans, Jef A J M; Hulshof, Lumbertus A

    2010-04-07

    A detailed study regarding the influence of microwave irradiation on the formation of a series of Grignard reagents in terms of rates and selectivities has revealed that these heterogeneous reactions may display a beneficial microwave effect. The interaction between microwaves and magnesium turnings generates violent electrostatic discharges. These discharges on magnesium lead to melting of the magnesium surface, thus generating highly active magnesium particles. As compared to conventional operation the microwave-induced discharges on the magnesium surface lead to considerably shorter initiation times for the insertion of magnesium in selected substrates (i.e. halothiophenes, halopyridines, octyl halides, and halobenzenes). Thermographic imaging and surface characterization by scanning electron microscopy showed that neither selective heating nor a "specific" microwave effect was causing the reduction in initiation times. This novel and straightforward initiation method eliminates the use of toxic and environmentally adverse initiators. Thus, this initiation method limits the formation of by-products. We clearly demonstrated that microwave irradiation enables fast Grignard reagent formation. Therefore, microwave technology is promising for process intensification of Grignard based coupling reactions.

  3. Mass lead intoxication from informal used lead-acid battery recycling in dakar, senegal.

    Science.gov (United States)

    Haefliger, Pascal; Mathieu-Nolf, Monique; Lociciro, Stephanie; Ndiaye, Cheikh; Coly, Malang; Diouf, Amadou; Faye, Absa Lam; Sow, Aminata; Tempowski, Joanna; Pronczuk, Jenny; Filipe Junior, Antonio Pedro; Bertollini, Roberto; Neira, Maria

    2009-10-01

    Between November 2007 and March 2008, 18 children died from a rapidly progressive central nervous system disease of unexplained origin in a community involved in the recycling of used lead-acid batteries (ULAB) in the suburbs of Dakar, Senegal. We investigated the cause of these deaths. Because autopsies were not possible, the investigation centered on clinical and laboratory assessments performed on 32 siblings of deceased children and 23 mothers and on 18 children and 8 adults living in the same area, complemented by environmental health investigations. All 81 individuals investigated were poisoned with lead, some of them severely. The blood lead level of the 50 children tested ranged from 39.8 to 613.9 microg/dL with a mean of 129.5 microg/dL. Seventeen children showed severe neurologic features of toxicity. Homes and soil in surrounding areas were heavily contaminated with lead (indoors, up to 14,000 mg/kg; outdoors, up to 302,000 mg/kg) as a result of informal ULAB recycling. Our investigations revealed a mass lead intoxication that occurred through inhalation and ingestion of soil and dust heavily contaminated with lead as a result of informal and unsafe ULAB recycling. Circumstantial evidence suggested that most or all of the 18 deaths were due to encephalopathy resulting from severe lead intoxication. Findings also suggest that most habitants of the contaminated area, estimated at 950, are also likely to be poisoned. This highlights the severe health risks posed by informal ULAB recycling, in particular in developing countries, and emphasizes the need to strengthen national and international efforts to address this global public health problem.

  4. Evaluation of electromechanical coupling parameters of piezoelectric materials by using piezoelectric cantilever with coplanar electrode structure in quasi-stasis.

    Science.gov (United States)

    Zheng, Xuejun; Zhu, Yuankun; Liu, Xun; Liu, Jing; Zhang, Yong; Chen, Jianguo

    2014-02-01

    Based on Timoshenko beam theory, a principle model is proposed to establish the relationship between electric charge and excitation acceleration, and in quasi-stasis we apply the direct piezoelectric effect of multilayer cantilever with coplanar electrode structure to evaluate the piezoelectric strain coefficient d15 and electromechanical coupling coefficient k15. They are measured as 678 pC/N and 0.74 for the commercial piezoelectric ceramic lead zirconate titanate (PZT-51) bulk specimen and 656 pC/N and 0.63 for the lead magnesium niobate (PMN) bulk specimen, and they are in agreement with the calibration and simulation values. The maximum of relative errors is less than 4.2%, so the proposed method is reliable and convenient.

  5. A study on lead equivalent

    International Nuclear Information System (INIS)

    Lin Guanxin

    1991-01-01

    A study on the rules in which the lead equivalent of lead glass changes with the energy of X rays or γ ray is described. The reason of this change is discussed and a new testing method of lead equivalent is suggested

  6. Superconducting magnets and leads thereto

    International Nuclear Information System (INIS)

    Biltcliffe, M.N.; Hanley, P.E.; McKinnon, J.B.; Wheatley, R.W.

    1975-01-01

    The magnet described comprises a cryostat containing a superconducting coil for the generation of a magnetic field, with a short-circuiting superconducting link connected across the coil, and electrical leads extending through the cryostat to the coil; these leads are provided with joints within the cryostat to enable them to be detached from the coil and removed from the cryostat without interrupting the current through the coil, thus reducing heat conduction to the cryostat through the leads. The joints are arranged so that the leads can be readily detached and re-attached to the coil from outside the cryostat. Gas-tight seals are provided where the leads pass through the outer wall of the cryostat, with caps that can be secured after removal of the leads. This kind of magnet can provide a stable magnetic field continuously over long periods, such as is required in nuclear magnetic resonance spectrometers. (U.K.)

  7. Stability of lithium niobate on irradiation at elevated temperature

    International Nuclear Information System (INIS)

    Primak, W.; Gavin, A.P.; Anderson, T.T.; Monahan, E.

    1977-01-01

    In contrast to results obtained for neutron irradiation in a thermal reactor near room temperature, lithium niobate plates irradiated in the Experimental Breeder Reactor II (EBR-II) did not become metamict. This is attributed to the elevated temperature of the EBR-II. Ion bombardment experiments indicate that to avoid disordering of lithium niobate on irradiation, its temperature should be maintained above 673 K. Evidence for ionic conductivity was found at 873 K, indicating that it would be inadvisable to permit the temperature to rise that high, particularly with voltage across the plate. In reactor application as a microphone transducer, it is tentatively recommended that the lithium niobate be maintained in the middle of this temperature range for a major portion of reactor operating time

  8. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  9. Forming lead-based anodes

    Energy Technology Data Exchange (ETDEWEB)

    Ogorodnichuk, V I; Voitsekhovich, R I

    1972-01-01

    Lead-based anodes can be produced by forming a layer of lead dioxide by chemical treatment in a solution of sulfuric acid in potassium permanganate at 80 to 100/sup 0/. The solution is mixed by compressed air. (RWR)

  10. Uptake and accumulation of lead by plants from the Bo Ngam lead mine area in Thailand

    International Nuclear Information System (INIS)

    Rotkittikhun, P.; Kruatrachue, M.; Chaiyarat, R.; Ngernsansaruay, C.; Pokethitiyook, P.; Paijitprapaporn, A.; Baker, A.J.M.

    2006-01-01

    A field survey of terrestrial plants growing on Bo Ngam lead mine area, Thailand, was conducted to identify species accumulating exceptionally high concentrations of lead. Plant and soil samples were collected from five areas. Lead concentrations in surface soil ranged from 325 to 142 400 mg/kg. The highest lead concentration in soil was found at the ore dressing plant area and lowest at a natural pond area. In different areas, the concentrations of lead in plants were different when comparing various study sites. A total of 48 plant species belonging to 14 families were collected from five sampling sites. Twenty-six plant species had lead concentrations more than 1000 mg/kg in their shoots. Three species (Microstegium ciliatum, Polygala umbonata, Spermacoce mauritiana) showed extremely high lead concentrations in their shoots (12 200-28 370 mg/kg) and roots (14 580-128 830 mg/kg). - Uptake and accumulation of lead by plants

  11. Lead exposures from varnished floor refinishing.

    Science.gov (United States)

    Schirmer, Joseph; Havlena, Jeff; Jacobs, David E; Dixon, Sherry; Ikens, Robert

    2012-01-01

    We evaluated the presence of lead in varnish and factors predicting lead exposure from floor refinishing and inexpensive dust suppression control methods. Lead in varnish, settled dust, and air were measured using XRF, laboratory analysis of scrape and wipe samples, and National Institute for Occupational Safety and Health (NIOSH) Method 7300, respectively, during refinishing (n = 35 homes). Data were analyzed using step-wise logistic regression. Compared with federal standards, no lead in varnish samples exceeded 1.0 mg/cm(2), but 52% exceeded 5000 ppm and 70% of settled dust samples after refinishing exceeded 40 μg/ft(2). Refinishing pre-1930 dwellings or stairs predicted high lead dust on floors. Laboratory analysis of lead in varnish was significantly correlated with airborne lead (r = 0.23, p = 0.014). Adding dust collection bags into drum sanders and HEPA vacuums to edgers and buffers reduced mean floor lead dust by 8293 μg Pb/ft(2) (pairborne lead exposures to less than 50 μg/m(3). Refinishing varnished surfaces in older housing produces high but controllable lead exposures.

  12. Lead and Hyperactivity: Lead Levels Among Hyperactive Children

    Science.gov (United States)

    David, Oliver J.; And Others

    1977-01-01

    In the study it is shown that within a group of 84 hyperactive children (4 to 11 years old) those for whom an organic etiology is present have lead burdens lower than in those for whom no apparent cause could be found. (Author/SBH)

  13. Magnesium and uranium ignition in different gaseous atmospheres

    International Nuclear Information System (INIS)

    Darras, R.; Baque, P.; Leclercq, D.

    1960-01-01

    Magnesium, uranium and some of their alloys burning temperatures have been systematically determined in an air or carbon dioxide atmosphere, either dry or wet. Two different ways of heating have been used: either continuously rising up the temperature, or heating to and then maintaining a constant temperature. The results are clearly different in the two cases. Besides, if moisture has little effect on the magnesium burning temperatures in air, it does lower them by about 130-140 deg. C in CO 2 . The differences of sight between the burning of magnesium and uranium have been noticed; this leads to distinguish between an 'ignition' and an 'inflammation'. (author) [fr

  14. Macroscopic polarization and thermoluminescence of barium niobate - sodium niobate

    International Nuclear Information System (INIS)

    Gorban', I.S.; Gumenyuk, A.F.; Omel'yanenko, V.A.

    1989-01-01

    Thermoluminescence (TL) of initial and thermally treated purposely undoped crystals of barium niobate - sodium has been studied within 85-400 K. The TL intensity is found to depend on the temperature to which the sample has been heated. A conclusion is drawn that nonstationarity of the TL properties is due to slowly occuring processes of compensation of pyrocharge, which depend on the temperatural prehistory of the sample. A mechanism of the traps transformation in a strong pyrofield of high-impedance crystals is discussed

  15. The impact of the new 36 V lead-acid battery systems on lead consumption

    Science.gov (United States)

    Prengaman, R. David

    The production of vehicles utilizing 36 V battery systems has begun with the introduction of the Toyota Crown. Other vehicles with 36 V batteries are in the near horizon. These vehicles may contain single or dual battery systems. These vehicles will most likely contain valve-regulated lead-acid (VRLA) batteries. The battery systems developed to date utilize significantly more lead than conventional 12 V batteries. This paper will evaluate the different proposed 36 V battery systems and estimate the lead requirements for each of the competing systems. It will also project the penetration of and resultant increased lead usage of these new batteries into the future.

  16. Biological characterization of lead-enhanced exopolysaccharide produced by a lead resistant Enterobacter cloacae strain P2B.

    Science.gov (United States)

    Naik, Milind Mohan; Pandey, Anju; Dubey, Santosh Kumar

    2012-09-01

    A lead resistant bacterial strain isolated from effluent of lead battery manufacturing company of Goa, India has been identified as Enterobacter cloacae strain P2B based on morphological, biochemical characters, FAME profile and 16S rDNA sequence data. This bacterial strain could resist lead nitrate up to 1.6 mM. Significant increase in exopolysaccharide (EPS) production was observed as the production increased from 28 to 108 mg/L dry weight when exposed to 1.6 mM lead nitrate in Tris buffered minimal medium. Fourier-transformed infrared spectroscopy of this EPS revealed presence of several functional groups involved in metal binding viz. carboxyl, hydroxyl and amide groups along with glucuronic acid. Gas chromatography coupled with mass spectrometry analysis of alditol-acetate derivatives of acid hydrolysed EPS produced in presence of 1.6 mM lead nitrate demonstrated presence of several neutral sugars such as rhamnose, arabinose, xylose, mannose, galactose and glucose, which contribute to lead binding hydroxyl groups. Scanning electron microscope coupled with energy dispersive X-ray spectrometric analysis of this lead resistant strain exposed to 1.6 mM lead nitrate interestingly revealed mucous EPS surrounding bacterial cells which sequestered 17 % lead (as weight %) extracellularly and protected the bacterial cells from toxic effects of lead. This lead resistant strain also showed multidrug resistance. Thus these results significantly contribute to better understanding of structure, function and environmental application of lead-enhanced EPSs produced by bacteria. This lead-enhanced biopolymer can play a very important role in bioremediation of several heavy metals including lead.

  17. Lead Intoxication in Children in Birmingham

    Science.gov (United States)

    Betts, P. R.; Astley, R.; Raine, D. N.

    1973-01-01

    Of 38 children investigated between 1966 and 1971 who had a blood lead concentration greater than 37 μg/100 ml eight had encephalopathy and one died; all these eight had a blood lead concentration of 99 μg/100 ml or above. Blood lead levels are related to haemoglobin concentrations and anaemia is common in children with blood lead concentrations of 37-60 μg/100 ml, levels previously accepted as harmless. Children with blood lead concentrations greater than 60 μg/100 ml show radiological evidence of lead intoxication, and treatment for this should be considered when blood lead concentration exceeds 37 μg/100 ml. Children presenting with unexplained encephalopathy should be radiographed for evidence of lead intoxication. ImagesFIG. 2FIG. 1 PMID:4691065

  18. Distribution of lead in teeth

    Energy Technology Data Exchange (ETDEWEB)

    Fremlin, J H; Tanti-Wipawin, W [Birmingham Univ. (UK). Dept. of Physics

    1976-07-01

    There is currently much concern with the amount of lead in the environment. Measurement of lead in teeth is being used to give information on the integrated uptake of lead by the individual over a period. The distribution of lead within individual teeth, is examined with the object of distinguishing lead deposited during formation or calcification from that taken up by the tooth over its working life after eruption. A tooth is sectioned and bombarded with 30-MeV ions of helium-3 from the Birmingham 1.52-m cyclotron, which produces polonium isotopes. The main useful activity is due to polonium-206, an ..cap alpha.. emitter, half-life 8 d. These ..cap alpha.. particles can be recorded by a plastic solid-state track detector.

  19. Distribution of lead in teeth

    International Nuclear Information System (INIS)

    Fremlin, J.H.; Tanti-Wipawin, W.

    1976-01-01

    There is currently much concern with the amount of lead in the environment. Measurement of lead in teeth is being used to give information on the integrated uptake of lead by the individual over a period. The distribution of lead within individual teeth, is examined with the object of distinguishing lead deposited during formation or calcification from that taken up by the tooth over its working life after eruption. A tooth is sectioned and bombarded with 30-MeV ions of helium-3 from the Birmingham 1.52-m cyclotron, which produces polonium isotopes. The main useful activity is due to polonium-206, an α emitter, half-life 8 d. These α particles can be recorded by a plastic solid-state track detector. (U.K.)

  20. Assessment of the body burden of chelatable lead: a model and its application to lead workers.

    Science.gov (United States)

    Araki, S; Ushio, K

    1982-01-01

    A hypothetical model was introduced to estimate the body burden of chelatable lead from the mobilisation yield of lead by calcium disodium ethylenediamine tetra-acetate (CaEDTA). It was estimated that, on average, 14 and 19% of the body burden was mobilised into the urine during the 24 hours after an injection of 53.4 mumol (20 mg) and 107 mumol (40 mg) CaEDTA per kg bodyweight, respectively. The body burden of chelatable lead ranged from 4 mumol (0.8 mg) to 120 mumol (24.9 mg) (mean 37 mumol (7.7 mg) in lead workers with blood lead concentrations of 0.3-2.9 mumol/kg (6-60 microgram/100 g) (mean 1.4 mumol/kg (29 microgram/100 g)). There were linear relationships between blood lead concentrations and body burden of chelatable lead on a log scale. PMID:6802167

  1. Lead poisoning following ingestion of pieces of lead roofing plates: pica-like behavior in an adult.

    Science.gov (United States)

    Sabouraud, Sabine; Testud, François; Descotes, Jacques; Benevent, Monique; Soglu, Gilbert

    2008-03-01

    A 37-year-old man was admitted to hospital after complaining of abdominal pain for the past two weeks. On admission the abdominal radiograph showed multiple radio-opaque flecks dispersed throughout the gastrointestinal tract. Blood testing showed hemoglobin level 8.7 g/dL and a blood lead level of 112.4 microg/dL. The family interview revealed that the patient had pica-like behavior since childhood. He was a site foreman and had been ingesting pieces of roofing plates for a few weeks. The patient was treated with laxatives and CaNa(2)EDTA therapy was initiated. The blood lead level then dropped to 69.9 microg/dL. The patient received two subsequent courses of oral succimer and the blood lead level decreased to 59 microg/dL 21 days after the first course. The follow-up abdominal X-ray 20 days after the first examination was normal. Four months later, an outpatient follow-up visit showed a blood lead level within normal limits (14.5 microg/dL) and a psychiatric follow-up was initiated. Lead poisoning following the ingestion of lead-containing foreign bodies is particularly rare in adults, while it is sometimes observed in children. Pica behavior is a well-identified risk factor of lead intoxication in children but is quite exceptional in adults, where it is usually considered to be a psychiatric condition. Other unusual sources of lead poisoning include the ingestion of lead bullets, ceramic lead glaze or glazed earthenware, lead-contaminated candies, ethnic or herbal remedies.

  2. Triple leads with longitudinal guarded cathodes in spinal cord stimulation-effect of transversal lead separation

    NARCIS (Netherlands)

    Sankarasubramanian, V.; Buitenweg, Jan R.; Holsheimer, J.

    2009-01-01

    In spinal cord stimulation (SCS) clinical practice, longitudinal guarded cathode stimulation by a single lead, placed on the spinal cord midline provides the broadest parasthesia coverage. This study uses a triple lead longitudinal tripole with the center lead placed on the midline. The transversal

  3. Lead-Related Genetic Loci, Cumulative Lead Exposure and Incident Coronary Heart Disease: The Normative Aging Study

    Science.gov (United States)

    Weisskopf, Marc G.; Sparrow, David; Schwartz, Joel; Hu, Howard; Park, Sung Kyun

    2016-01-01

    Background Cumulative exposure to lead is associated with cardiovascular outcomes. Polymorphisms in the δ-aminolevulinic acid dehydratase (ALAD), hemochromatosis (HFE), heme oxygenase-1 (HMOX1), vitamin D receptor (VDR), glutathione S-transferase (GST) supergene family (GSTP1, GSTT1, GSTM1), apolipoprotein E (APOE),angiotensin II receptor-1 (AGTR1) and angiotensinogen (AGT) genes, are believed to alter toxicokinetics and/or toxicodynamics of lead. Objectives We assessed possible effect modification by genetic polymorphisms in ALAD, HFE, HMOX1, VDR, GSTP1, GSTT1, GSTM1, APOE, AGTR1 and AGT individually and as the genetic risk score (GRS) on the association between cumulative lead exposure and incident coronary heart disease (CHD) events. Methods We used K-shell-X-ray fluorescence to measure bone lead levels. GRS was calculated on the basis of 22 lead-related loci. We constructed Cox proportional hazard models to compute adjusted hazard ratios (HRs) and 95% confidence intervals (CIs) for incident CHD. We applied inverse probability weighting to account for potential selection bias due to recruitment into the bone lead sub-study. Results Significant effect modification was found by VDR, HMOX1, GSTP1, APOE, and AGT genetic polymorphisms when evaluated individually. Further, the bone lead-CHD associations became larger as GRS increases. After adjusting for potential confounders, a HR of CHD was 2.27 (95%CI: 1.50–3.42) with 2-fold increase in patella lead levels, among participants in the top tertile of GRS. We also detected an increasing trend in HRs across tertiles of GRS (p-trend = 0.0063). Conclusions Our findings suggest that lead-related loci as a whole may play an important role in susceptibility to lead-related CHD risk. These findings need to be validated in a separate cohort containing bone lead, lead-related genetic loci and incident CHD data. PMID:27584680

  4. Lead user projects in practice

    DEFF Research Database (Denmark)

    Brem, Alexander; Gutstein, Adele

    2018-01-01

    Earlier research on the lead user method is focused on individual case studies and how the method was applied in a specific context. In this paper, we take a broader approach, analyzing a sample of 24 lead user projects, which included working with 188 lead users. These projects were analyzed...

  5. Determination of lead in human calculi and its effects on renal function of lead occupational workers

    International Nuclear Information System (INIS)

    Memon, F.; Vasandani, A.G.M.

    2016-01-01

    Seventy five samples of renal and eighteen samples of supra gingival calculi of lead recycling workers were collected over the period of seven years (2008-2014) and studied for the accumulation of lead. The results were compared with those of non exposed subjects. The lead content of calculi was investigated for its dependence on type and composition of calculi, blood lead, job status and duration of exposure. The effect of blood lead and renal calculi was also investigated in relation to kidney function of respective subjects. The mean lead levels of various types of calculi were found to follow the order as phosphate > oxalate > urate > cystine while single principal group of supra gingival calculi resulted in lower levels of metal. The lead content of calculi positively correlated with phosphate content of both of the renal (r = 0.655) and supra gingival calculi (r= 0.866). Impaired renal function was more pronounced in active workers and depended on blood lead levels in addition to presence of metal in renal calculi. (author)

  6. Giant Piezoelectricity and High Curie Temperature in Nanostructured Alkali Niobate Lead-Free Piezoceramics through Phase Coexistence.

    Science.gov (United States)

    Wu, Bo; Wu, Haijun; Wu, Jiagang; Xiao, Dingquan; Zhu, Jianguo; Pennycook, Stephen J

    2016-11-30

    Because of growing environmental concerns, the development of lead-free piezoelectric materials with enhanced properties has become of great interest. Here, we report a giant piezoelectric coefficient (d 33 ) of 550 pC/N and a high Curie temperature (T C ) of 237 °C in (1-x-y)K 1-w Na w Nb 1-z Sb z O 3- xBiFeO 3- yBi 0.5 Na 0.5 ZrO 3 (KN w NS z -xBF-yBNZ) ceramics by optimizing x, y, z, and w. Atomic-resolution polarization mapping by Z-contrast imaging reveals the intimate coexistence of rhombohedral (R) and tetragonal (T) phases inside nanodomains, that is, a structural origin for the R-T phase boundary in the present KNN system. Hence, the physical origin of high piezoelectric performance can be attributed to a nearly vanishing polarization anisotropy and thus low domain wall energy, facilitating easy polarization rotation between different states under an external field.

  7. Lead user projects in practice

    DEFF Research Database (Denmark)

    Brem, Alexander; Gutstein, Adele

    2018-01-01

    Earlier research on the lead user method is focused on individual case studies and how the method was applied in a specific context. In this paper, we take a broader approach, analyzing a sample of 24 lead user projects, which included working with 188 lead users. These projects were analyzed....... Moreover, crowdsourcing contests and netnography proved to be of significant value for the need, trend, and lead user identification phases. This paper concludes by discussing theoretical and practical implications, the limitations of this study, and recommendations for future studies....

  8. Rare-Earth Tantalates and Niobates Single Crystals: Promising Scintillators and Laser Materials

    Directory of Open Access Journals (Sweden)

    Renqin Dou

    2018-01-01

    Full Text Available Rare-earth tantalates, with high density and monoclinic structure, and niobates with monoclinic structure have been paid great attention as potential optical materials. In the last decade, we focused on the crystal growth technology of rare-earth tantalates and niobates and studied their luminescence and physical properties. A series of rare-earth tantalates and niobates crystals have been grown by the Czochralski method successfully. In this work, we summarize the research results on the crystal growth, scintillation, and laser properties of them, including the absorption and emission spectra, spectral parameters, energy levels structure, and so on. Most of the tantalates and niobates exhibit excellent luminescent properties, rich physical properties, and good chemical stability, indicating that they are potential outstanding scintillators and laser materials.

  9. Isotopic analysis of bullet lead samples

    International Nuclear Information System (INIS)

    Sankar Das, M.; Venkatasubramanian, V.S.; Sreenivas, K.

    1976-01-01

    The possibility of using the isotopic composition of lead for the identification of bullet lead is investigated. Lead from several spent bullets were converted to lead sulphide and analysed for the isotopic abundances using an MS-7 mass spectrometer. The abundances are measured relative to that for Pb 204 was too small to permit differentiation, while the range of variation of Pb 206 and Pb 207 and the better precision in their analyses permitted differentiating samples from one another. The correlation among the samples examined has been pointed out. The method is complementary to characterisation of bullet leads by the trace element composition. The possibility of using isotopically enriched lead for tagging bullet lead is pointed out. (author)

  10. Effect of Glycine on Lead Mobilization, Lead-Induced Oxidative Stress, and Hepatic Toxicity in Rats

    Directory of Open Access Journals (Sweden)

    Yolanda Alcaraz-Contreras

    2011-01-01

    Full Text Available The effectiveness of glycine in treating experimental lead intoxication was examined in rats. Male Wistar rats were exposed to 3 g/L lead acetate in drinking water for 5 weeks and treated thereafter with glycine (100 and 500 mg/kg, orally once daily for 5 days or glycine (1000 mg/kg, orally once daily for 28 days. The effect of these treatments on parameters indicative of oxidative stress (glutathione and malondialdehyde levels, the activity of blood -aminolevulinic acid dehydratase, and lead concentration in blood, liver, kidney, brain, and bone were investigated. Liver samples were observed for histopathological changes. Glycine was found to be effective in (1 increasing glutathione levels; (2 reducing malondialdehyde levels; (3 decreasing lead levels in bone with the highest dose. However, glycine had no effect on lead mobilization when 100 and 500 mg/kg glycine were administered. In microscopic examination, glycine showed a protective effect against lead intoxication.

  11. Leading change.

    Science.gov (United States)

    2017-02-27

    In response to feedback from nursing, midwifery and other care staff who wanted to understand better how the Leading Change, Adding Value framework applies to them, NHS England has updated its webpage to include practice examples.

  12. Lead concentration in meat from lead-killed moose and predicted human exposure using Monte Carlo simulation.

    Science.gov (United States)

    Lindboe, M; Henrichsen, E N; Høgåsen, H R; Bernhoft, A

    2012-01-01

    Lead-based hunting ammunitions are still common in most countries. On impact such ammunition releases fragments which are widely distributed within the carcass. In Norway, wild game is an important meat source for segments of the population and 95% of hunters use lead-based bullets. In this paper, we have investigated the lead content of ground meat from moose (Alces alces) intended for human consumption in Norway, and have predicted human exposure through this source. Fifty-two samples from different batches of ground meat from moose killed with lead-based bullets were randomly collected. The lead content was measured by atomic absorption spectroscopy. The lead intake from exposure to moose meat over time, depending on the frequency of intake and portion size, was predicted using Monte Carlo simulation. In 81% of the batches, lead levels were above the limit of quantification of 0.03 mg kg(-1), ranging up to 110 mg kg(-1). The mean lead concentration was 5.6 mg kg(-1), i.e. 56 times the European Commission limit for lead in meat. For consumers eating a moderate meat serving (2 g kg(-1) bw), a single serving would give a lead intake of 11 µg kg(-1) bw on average, with maximum of 220 µg kg(-1) bw. Using Monte Carlo simulation, the median (and 97.5th percentile) predicted weekly intake of lead from moose meat was 12 µg kg(-1) bw (27 µg kg(-1) bw) for one serving per week and 25 µg kg(-1) bw (45 µg kg(-1) bw) for two servings per week. The results indicate that the intake of meat from big game shot with lead-based bullets imposes a significant contribution to the total human lead exposure. The provisional tolerable weekly intake set by the World Health Organization (WHO) of 25 µg kg(-1) bw is likely to be exceeded in people eating moose meat on a regular basis. The European Food Safety Authority (EFSA) has recently concluded that adverse effects may be present at even lower exposure doses. Hence, even occasional consumption of big game meat with lead levels as

  13. Large Piezoelectric Strain with Superior Thermal Stability and Excellent Fatigue Resistance of Lead-Free Potassium Sodium Niobate-Based Grain Orientation-Controlled Ceramics.

    Science.gov (United States)

    Quan, Yi; Ren, Wei; Niu, Gang; Wang, Lingyan; Zhao, Jinyan; Zhang, Nan; Liu, Ming; Ye, Zuo-Guang; Liu, Liqiang; Karaki, Tomoaki

    2018-03-19

    Environment-friendly lead-free piezoelectric materials with high piezoelectric response and high stability in a wide temperature range are urgently needed for various applications. In this work, grain orientation-controlled (with a 90% ⟨001⟩ c -oriented texture) (K,Na)NbO 3 -based ceramics with a large piezoelectric response ( d 33 *) = 505 pm V -1 and a high Curie temperature ( T C ) of 247 °C have been developed. Such a high d 33 * value varies by less than 5% from 30 to 180 °C, showing a superior thermal stability. Furthermore, the high piezoelectricity exhibits an excellent fatigue resistance with the d 33 * value decreasing within only by 6% at a field of 20 kV cm -1 up to 10 7 cycles. These exceptional properties can be attributed to the vertical morphotropic phase boundary and the highly ⟨001⟩ c -oriented textured ceramic microstructure. These results open a pathway to promote lead-free piezoelectric ceramics as a viable alternative to lead-based piezoceramics for various practical applications, such as actuators, transducers, sensors, and acoustic devices, in a wide temperature range.

  14. Petrol with isotopically differentiated lead added

    International Nuclear Information System (INIS)

    Magi, F.; Facchetti, S.; Garibaldi, P.

    1975-01-01

    An experiment is proposed aimed at determining the role of motor traffic in the pollution of the environment by lead, in particular of air, soil, vegetation, food and the human body. The technique of determining the isotopic composition of lead, used in the right way, should enable the whole problem to be solved. It is intended to add lead with a constant isotopic composition different from that of normally occuring lead, whether natural in origin or otherwise, to petrol in at least two regions of Italy. Analyses of lead samples taken from the principal mines have shown that Australian lead (Broken Hill Mine) has quite a different isotopic composition. This lead will therefore be used to prepare the antiknock additives for petrol sold in the regions in question. Adequate sampling should make it possible to determine the contribution to pollution of lead from motor vehicle exhausts. The regions chosen for the experiment are Piedmont (city and province of Turin) and Sardinia (city and province of Cagliari) - the first because of its high traffic density and level of industrialization, the second because of its remoteness and the lead content of the soil, which may affect food. Both regions present favourable conditions for supplying petrol of the intended type. The experiment is intended to last three years; the petrol with Australian lead will be marketed for a period of 18 months. The first results of analyses of the isotopic composition of lead contained in atmospheric dust in the city of Turin and of lead from a number of blood samples are reported in the paper

  15. Radioactive lead studies in the human

    International Nuclear Information System (INIS)

    Blake, K.C.H.

    1980-08-01

    The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, 203 Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when 203 Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested 203 Pb in control meals from which one dietary constituent at a time was omitted. Calcium and phosphorous were found to reduce the absorption of 203 Pb to approximately the same level as that produced by the total minerals. Calcium reduced absorption more than phosphorous when these minerals were ingested separately with 203 Pb. It was concluded that the calcium and phosphorous in the diet could influence susceptibility to lead toxicity through changes in the absorption of food and water lead and in the distribution of lead in the body. The results suggest that the prophylactic effect of calcium on lead absorption should be recognised and applied in this time of increased environmental levels of lead

  16. Lead poisoning in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Bond, E; Kubin, R

    1949-01-01

    Diagnosis was made from clinical observation and laboratory examination of nine cases. A successful treatment is described based on the similarity of the metabolism of lead and calcium, the lead being deposited in the bones where it is harmless, if it remains there. Details are given of the treatment.

  17. Identification of sources of lead exposure in French children by lead isotope analysis: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Lucas Jean-Paul

    2011-08-01

    Full Text Available Abstract Background The amount of lead in the environment has decreased significantly in recent years, and so did exposure. However, there is no known safe exposure level and, therefore, the exposure of children to lead, although low, remains a major public health issue. With the lower levels of exposure, it is becoming more difficult to identify lead sources and new approaches may be required for preventive action. This study assessed the usefulness of lead isotope ratios for identifying sources of lead using data from a nationwide sample of French children aged from six months to six years with blood lead levels ≥25 μg/L. Methods Blood samples were taken from 125 children, representing about 600,000 French children; environmental samples were taken from their homes and personal information was collected. Lead isotope ratios were determined using quadrupole ICP-MS (inductively coupled plasma - mass spectrometry and the isotopic signatures of potential sources of exposure were matched with those of blood in order to identify the most likely sources. Results In addition to the interpretation of lead concentrations, lead isotope ratios were potentially of use for 57% of children aged from six months to six years with blood lead level ≥ 25 μg/L (7% of overall children in France, about 332,000 children, with at least one potential source of lead and sufficiently well discriminated lead isotope ratios. Lead isotope ratios revealed a single suspected source of exposure for 32% of the subjects and were able to eliminate at least one unlikely source of exposure for 30% of the children. Conclusions In France, lead isotope ratios could provide valuable additional information in about a third of routine environmental investigations.

  18. Leading change: a concept analysis.

    Science.gov (United States)

    Nelson-Brantley, Heather V; Ford, Debra J

    2017-04-01

    To report an analysis of the concept of leading change. Nurses have been called to lead change to advance the health of individuals, populations, and systems. Conceptual clarity about leading change in the context of nursing and healthcare systems provides an empirical direction for future research and theory development that can advance the science of leadership studies in nursing. Concept analysis. CINAHL, PubMed, PsycINFO, Psychology and Behavioral Sciences Collection, Health Business Elite and Business Source Premier databases were searched using the terms: leading change, transformation, reform, leadership and change. Literature published in English from 2001 - 2015 in the fields of nursing, medicine, organizational studies, business, education, psychology or sociology were included. Walker and Avant's method was used to identify descriptions, antecedents, consequences and empirical referents of the concept. Model, related and contrary cases were developed. Five defining attributes of leading change were identified: (a) individual and collective leadership; (b) operational support; (c) fostering relationships; (d) organizational learning; and (e) balance. Antecedents were external or internal driving forces and organizational readiness. The consequences of leading change included improved organizational performance and outcomes and new organizational culture and values. A theoretical definition and conceptual model of leading change were developed. Future studies that use and test the model may contribute to the refinement of a middle-range theory to advance nursing leadership research and education. From this, empirically derived interventions that prepare and enable nurses to lead change to advance health may be realized. © 2016 John Wiley & Sons Ltd.

  19. Exciton-relaxation dynamics in lead halides

    International Nuclear Information System (INIS)

    Iwanaga, Masanobu; Hayashi, Tetsusuke

    2003-01-01

    We survey recent comprehensive studies of exciton relaxation in the crystals of lead halides. The luminescence and electron-spin-resonance studies have revealed that excitons in lead bromide spontaneously dissociate and both electrons and holes get self-trapped individually. Similar relaxation has been also clarified in lead chloride. The electron-hole separation is ascribed to repulsive correlation via acoustic phonons. Besides, on the basis of the temperature profiles of self-trapped states, we discuss the origin of luminescence components which are mainly induced under one-photon excitation into the exciton band in lead fluoride, lead chloride, and lead bromide

  20. Lead in soils, plants and animals

    Energy Technology Data Exchange (ETDEWEB)

    Scheltinga, H

    1955-01-01

    The toxicity of lead for plants is small, except in the case of water cultures. Animals can absorb more lead without toxic effect than was previously expected. This applies to acute poisoning as well as chronic poisoning. As a result of experiments over many years (Allcroft and Blaxter, 1950) the possibility of chronic lead poisoning has been found to be minute. Rations containing 240 mg lead/kg dried fodder, given daily over a period of three years, did not cause any poisoning at all in cattle thus fed. Where lead poisoning did take place, it was observed that the ratio of lead in the dried fodder was > 1000 mg/kg; the proportion was generally much higher. In normal cases grass contains only 5 to 15 mg lead/kg. The total lead content of samples from arable land was 10 to 25 mg/kg soil. For grassland on peat or clay the amount was slightly higher. The influence on the lead status of soils and plants of fertilizing with compost or copper slag flour, both containing a small percentage of lead, proved to be negligible. It is definite that in normal use, these fertilizers cannot cause any danger for either plant or animal. 24 references, 3 tables.

  1. Results from the Cooler and Lead Tests

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10 6 m -1 . The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10 6 A m -1 . This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  2. Leading Educational Change Wisely

    Science.gov (United States)

    Forrester, Gillian

    2011-01-01

    In this article, the author reviews Christopher Branson's book entitled "Leading Educational Change Wisely". The book provides an alternative and engaging perspective on leading educational change. Branson utilises "wisdom" as its central conceptual device to present a thought-provoking and philosophical account on how leaders are able to build a…

  3. Hunting with lead: association between blood lead levels and wild game consumption.

    Science.gov (United States)

    Iqbal, Shahed; Blumenthal, Wendy; Kennedy, Chinaro; Yip, Fuyuen Y; Pickard, Stephen; Flanders, W Dana; Loringer, Kelly; Kruger, Kirby; Caldwell, Kathleen L; Jean Brown, Mary

    2009-11-01

    Wild game hunting is a popular activity in many regions of the United States. Recently, the presence of lead fragments in wild game meat, presumably from the bullets or shot used for hunting, has raised concerns about health risks from meat consumption. This study examined the association between blood lead levels (PbB) and wild game consumption. We recruited 742 participants, aged 2-92 years, from six North Dakota cities. Blood lead samples were collected from 736 persons. Information on socio-demographic background, housing, lead exposure source, and types of wild game consumption (i.e., venison, other game such as moose, birds) was also collected. Generalized estimating equations (GEE) were used to determine the association between PbB and wild game consumption. Most participants reported consuming wild game (80.8%) obtained from hunting (98.8%). The geometric mean PbB were 1.27 and 0.84 microg/dl among persons who did and did not consume wild game, respectively. After adjusting for potential confounders, persons who consumed wild game had 0.30 microg/dl (95% confidence interval: 0.16-0.44 microg/dl) higher PbB than persons who did not. For all game types, recent (game consumption was associated with higher PbB. PbB was also higher among those who consumed a larger serving size (> or = 2 oz vs. game' consumption only. Participants who consumed wild game had higher PbB than those who did not consume wild game. Careful review of butchering practices and monitoring of meat-packing processes may decrease lead exposure from wild game consumption.

  4. {beta}-adrenergic receptor density and adenylate cyclase activity in lead-exposed rat brain after cessation of lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Huoy-Rou [I-Shou University, Department of Biomedical Engineering, Dashu Shiang, Kaohsiung County (Taiwan); Tsao, Der-An [Fooyin University of Technology, Department of Medical Technology (Taiwan); Yu, Hsin-Su [Taiwan University, Department of Dermatology, College of Medicine (Taiwan); Ho, Chi-Kung [Kaohsiung Medical University, Occupational Medicine (Taiwan); Kaohsiung Medical University, Graduate Institute of Medicine, Research Center for Occupational Disease (Taiwan)

    2005-01-01

    To understanding the reversible or irreversible harm to the {beta}-adrenergic system in the brain of lead-exposed rats, this study sets up an animal model to estimate the change in the sympathetic nervous system of brain after lead exposure was withdrawn. We address the following topics in this study: (a) the relationship between withdrawal time of lead exposure and brain {beta}-adrenergic receptor, blood lead level, and brain lead level in lead-exposed rats after lead exposure was stopped; and (b) the relationship between lead level and {beta}-adrenergic receptor and cyclic AMP (c-AMP) in brain. Wistar rats were chronically fed with 2% lead acetate and water for 2 months. Radioligand binding was assayed by a method that fulfilled strict criteria of {beta}-adrenergic receptor using the ligand [{sup 125}I]iodocyanopindolol. The levels of lead were determined by electrothermal atomic absorption spectrometry. The c-AMP level was determined by radioimmunoassay. The results showed a close relationship between decreasing lead levels and increasing numbers of brain {beta}-adrenergic receptors and brain adenylate cyclase activity after lead exposure was withdrawn. The effect of lead exposure on the {beta}-adrenergic system of the brain is a partly reversible condition. (orig.)

  5. Lead (Pb) isotopic fingerprinting and its applications in lead pollution studies in China: A review

    International Nuclear Information System (INIS)

    Cheng Hefa; Hu Yuanan

    2010-01-01

    As the most widely scattered toxic metal in the world, the sources of lead (Pb) observed in contamination investigation are often difficult to identify. This review presents an overview of the principles, analysis, and applications of Pb isotopic fingerprinting in tracing the origins and transport pathways of Pb in the environment. It also summarizes the history and current status of lead pollution in China, and illustrates the power of Pb isotopic fingerprinting with examples of its recent applications in investigating the effectiveness of leaded gasoline phase-out on atmospheric lead pollution, and the sources of Pb found in various environmental media (plants, sediments, and aquatic organisms) in China. The limitations of Pb isotopic fingerprinting technique are discussed and a perspective on its development is also presented. Further methodological developments and more widespread instrument availability are expected to make isotopic fingerprinting one of the key tools in lead pollution investigation. - This review presents an overview of the principles, applications, and limitations of Pb isotopic fingerprinting in lead pollution investigation, and provides a perspective on its future development.

  6. Lead poisoning in domestic ducks

    Energy Technology Data Exchange (ETDEWEB)

    Rac, R; Crisp, C S

    1954-05-01

    The death of wild ducks, due to the ingestion of lead shop, occurs frequently and is well documented. This paper discusses the death of domestic ducks due to the ingestion of lead. It describes the symptoms, and pathology of the lead poisoning of a clutch of 11 ducklings which were being raised on a farm in Australia. 3 references, 1 table.

  7. Lead-free primary explosives

    Science.gov (United States)

    Huynh, My Hang V.

    2010-06-22

    Lead-free primary explosives of the formula (cat).sub.Y[M.sup.II(T).sub.X(H.sub.2O).sub.6-X].sub.Z, where T is 5-nitrotetrazolate, and syntheses thereof are described. Substantially stoichiometric equivalents of the reactants lead to high yields of pure compositions thereby avoiding dangerous purification steps.

  8. Remediation of lead-contaminated soils

    International Nuclear Information System (INIS)

    Peters, R.W.; Shem, L.

    1992-01-01

    Excavation and transport of soil contaminated with heavy metals has generally been the standard remediation technique for treatment of heavy-metal-contaminated soils. This approach is not a permanent solution; moreover, off-site shipment and disposal of contaminated soil involves high expense, liability, and appropriate regulatory approval. Recently, a number of other techniques have been investigated for treating such contaminated sites, including flotation, solidification/stabilization, vitrification, and chemical extraction. This paper reports the results of a laboratory investigation determining the efficiency of using chelating agents to extract lead from contaminated soils. Lead concentrations in the soils ranged from 500 to 10,000 mg/kg. Ethylenediaminetetraacetic acid (EDTA) and nitrilotriacetic acid (NTA) were examined for their potential extractive capabilities. Concentrations of the chelating agents ranged from 0.01 to 0.10 M. The pH of the suspensions in which the extractions were performed ranged from 4 to 12. Results showed that the removal of lead using NTA and water was ph-dependent, whereas the removal of lead using EDTA was ph-insensitive. Maximum removals of lead were 68.7%,19.1%, and 7.3% using EDTA, NTA, and water, respectively (as compared with initial lead concentrations)

  9. Investigation of lead workers for subclinical effects of lead using three performance tests

    Energy Technology Data Exchange (ETDEWEB)

    Milburn, H; Mitran, E; Crockford, G W

    1976-12-01

    Using three performance tests, lead exposed workers were studied for signs of subclinical neurological effects. The three tests were: two flash fusion threshold, a test considered to indicate the level of arousal; reaction time to a touch stimulus and the rate at which hand grip pressure is developed, both influenced by the conduction velocity of the peripheral nerves and impulse transmission across the motor end plates. Sixteen male lead workers were tested and compared with a non-exposed matched control group of fifteen. The occupational history, neurological symptoms and blood lead levels were recorded. The three performance tests revealed no differences between the exposed and the non-exposed groups.

  10. Lead-iron phosophate glass

    International Nuclear Information System (INIS)

    Sales, B.C.; Boatner, L.A.

    1988-01-01

    The lead-iron phosphate nuclear waste glasses (LIPNWG) are the subject of the present chapter. They were discovered in 1984 while the authors were attempting to find a sintering aid for certain types of crystalline monazite ceramic high-level nuclear waste forms. In the present chapter, the term waste glass is synonymous with nuclear waste glass (NWG), and the acronym LIP is often used for lead-iron phosphate. Lead-iron phosphate glasses, like many of the previously studied phosphate glasses, are corrosion resistant in aqueous solutions at temperatures below 100 degrees C, and they can be melted and poured at temperatures that are relatively low in comparison with the processing temperatures required for current silicate glass compositions. Unlike the phosphate glasses investigated previously, however, LIPNWGs do not suffer from alteration due to devitrification during realistic and readily, achievable cooling periods. Additionally, lead-iron phosphate glass melts are not nearly as corrosive as the sodium phosphate melts investigated during the 1960s; and, therefore, they can be melted and processed using crucibles made from a variety of materials

  11. Lead pollution in Islamabad

    International Nuclear Information System (INIS)

    Mohammad, D.; Khatoon, N.; Ishaque, M.; Ahmed, I.

    1997-01-01

    Lead pollution of urban area emanating from the vehicular exhaust alone is being labeled as one of the worst form of environmental degradation attracting our attention for remediation. For factual assessment samples were collected from different areas of Islamabad. These samples consisted of tree scrapings / peelings, which were dried and ground before undertaking analysis for the lead content. The samples were digested with an acid mixture to remove the organic matter and analyzed using GFAAS technique. A total of 81 samples have been analyzed. The results sowed a lead content varying in the range of 8-474 Mu g g/sup -1/) and 23 samples with Pb content <50 Mu g g-1 (8.0-50.0 Mu g g/sup -1/). Most of the samples also contained some growth which consisted of bacterial, algae and fugal cells and the results have been explained on the basis of Pb absorption by these cells. The procedure followed in this study is recommended for evaluation of lead pollution in urban areas. (author)

  12. QUALITY OF YOGHURTS FROM GOAT'S MILK ENRICHED WITH MAGNESIUM CHLORIDE

    Directory of Open Access Journals (Sweden)

    Agata Znamirowska

    2015-02-01

    Full Text Available Goat’s milk can be enriched with magnesium in the form of chloride before pasteurization with a save dose, i.e. 20 mg of magnesium for 100 g of milk. Higher doses of magnesium can lead to coagulation of proteins since together with the increase of the dose of fortification there increases general acidity while pH of milk decreases. Together with the increase of the dose of fortification of yoghurts with magnesium there was shown an essential proportional increase of acidity and hardness of curds persisting for 21 days of storage. Enriching goat’s milk yoghurts with magnesium decreased the intensity of „goat” smell and aftertaste and did not cause a change in colour. The most favourable solution is the production of goat’s milk yoghurts enriched with 10-20 mg of magnesium in the form of magnesium chloride. Such doses of enrichment caused successive lowering of perceptibility of „goat” aftertaste and smell together with extension of storage time.

  13. SU-E-P-09: Radiation Transmission Measurements and Evaluation of Diagnostic Lead-Based and Lead-Free Aprons

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2014-06-01

    Purpose: This study was conducted to ensure that various lead shield apron manufacturers provided accurate attenuation factors regardless of whether the apron was made of lead-based or lead-free equivalent material. Methods: A calibrated ionization survey meter was placed at chest height and 36 cm horizontally away from a solid water phantom on a simulator couch. Measurements were done with or without apron. Radiation field was set to 24cmx24cm with the phantom at 100cm source-to-surface distance. Irradiation time was set for 1 minute at voltages of 60, 80, 100 and 120 kVp. Current was set at 6mA. Results: Between 60 kVp and 120 kVp, the transmission through 0.50 mm of lead-based apron was between 1.0% and 6.5% with a mean value of 3.2% and a standard deviation (s.d.) of 1.4%. The transmissions through the 0.50 mm lead-free aprons were 1.0 % to 12.0% with a mean value of 6.1% and s.d. of 2.6%. At 120 kVp, the transmission value was 6.5% for 0.50 mm lead-based apron and 11.1% to 12.0% for 0.50 mm lead-free aprons. The radiation transmissions at 80 kVp, measured in two different 0.5 mm lead-free aprons, were 4.3% each. However, only 1.4% transmission was found through the lead-based apron. Overall, the radiation transmitted through the lead-based apron was 1/3 transmission of lead-free at 80kVp, and half value of lead-free aprons at 100 and 120 kVp. Conclusion: Even though lead-based and lead-free aprons all claimed to have the same lead equivalent thickness, the transmission might not be the same. The precaution was needed to exercise diligence in quality assurance program to assure adequate protection to staff who wear it during diagnostic procedures. The requirement for aprons not only should be in certain thickness to meet state regulation but also to keep reasonably achievable low exposure with the accurate labeling from manufacturers.

  14. SU-E-P-09: Radiation Transmission Measurements and Evaluation of Diagnostic Lead-Based and Lead-Free Aprons

    International Nuclear Information System (INIS)

    Syh, J

    2014-01-01

    Purpose: This study was conducted to ensure that various lead shield apron manufacturers provided accurate attenuation factors regardless of whether the apron was made of lead-based or lead-free equivalent material. Methods: A calibrated ionization survey meter was placed at chest height and 36 cm horizontally away from a solid water phantom on a simulator couch. Measurements were done with or without apron. Radiation field was set to 24cmx24cm with the phantom at 100cm source-to-surface distance. Irradiation time was set for 1 minute at voltages of 60, 80, 100 and 120 kVp. Current was set at 6mA. Results: Between 60 kVp and 120 kVp, the transmission through 0.50 mm of lead-based apron was between 1.0% and 6.5% with a mean value of 3.2% and a standard deviation (s.d.) of 1.4%. The transmissions through the 0.50 mm lead-free aprons were 1.0 % to 12.0% with a mean value of 6.1% and s.d. of 2.6%. At 120 kVp, the transmission value was 6.5% for 0.50 mm lead-based apron and 11.1% to 12.0% for 0.50 mm lead-free aprons. The radiation transmissions at 80 kVp, measured in two different 0.5 mm lead-free aprons, were 4.3% each. However, only 1.4% transmission was found through the lead-based apron. Overall, the radiation transmitted through the lead-based apron was 1/3 transmission of lead-free at 80kVp, and half value of lead-free aprons at 100 and 120 kVp. Conclusion: Even though lead-based and lead-free aprons all claimed to have the same lead equivalent thickness, the transmission might not be the same. The precaution was needed to exercise diligence in quality assurance program to assure adequate protection to staff who wear it during diagnostic procedures. The requirement for aprons not only should be in certain thickness to meet state regulation but also to keep reasonably achievable low exposure with the accurate labeling from manufacturers

  15. Lead poisoning in cattle and sheep

    Energy Technology Data Exchange (ETDEWEB)

    Allcroft, R

    1951-09-15

    The danger of paint and other lead compounds to the bovine is well recognized and has been recorded and discussed fairly extensively from time to time. The literature indicates that the calf is extremely susceptible to lead poisoning, but relatively little has been reported regarding the levels of lead in tissues of animals which have died as a result of lead poisoning, and still less in animals suspected of suffering from sub-lethal doses of lead compounds. In order to provide sufficient data to enable interpretation of figures obtained from tissues in cases of suspected lead poisoning sent in from the field, and to provide information on the metabolic fate of lead in ruminants, investigations were made at Weybridge on the absorption, excretion, retention and general metabolic effects of lead in both cattle and sheep and the results have been published in a series of five papers. In this brief review it is intended to discuss points from these and subsequent investigations which are likely to be of interest to the veterinarian.

  16. Community blood lead survey with emphasis on preschool children following lead dust pollution in Esperance, Western Australia.

    Science.gov (United States)

    Rossi, Enrico; McLaughlin, Virginia; Joseph, John; Bulsara, Max; Coleman, Kerryn; Douglas, Charles; Robertson, Andrew

    2012-04-01

    To assess the impact of airborne lead dust on blood lead levels in residents of Esperance, a regional Western Australian town, with particular reference to preschool children. Following identification of significant airborne lead contamination, residents were notified that a blood lead clinic was available to all, with testing of preschool children encouraged. About 40% (333 children) of the preschool group and about 20% of the remaining population were tested. The main measures were blood lead levels, prevalence of elevated results and comparisons to other Western Australian surveys. In preschoolers, 2.1% (seven children) had blood lead levels exceeding the current 10 μg/dL level of concern. This was not significantly different to two previous community-based surveys elsewhere in Western Australia. However, at a lower cut-off of 5 μg/dL, the prevalence of elevated lead levels was 24.6%, significantly higher than children tested in a previous Western Australian survey. The prevalence of blood lead levels of 10 μg/dL or greater in adults was 1.3% (26 adults), not significantly different from a previous Western Australian survey. The prevalence of preschool children with blood lead levels exceeding the current level of concern was not significantly increased. However, the increased prevalence of children with lead levels at or above 5 μg/dL demonstrates exposure to lead dust pollution. This episode of lead dust contamination highlights the need for strict adherence to environmental controls and effective monitoring processes to ensure the prevention of future events. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.

  17. Stable lead isotopes and lake sediments. A useful combination for the study of atmospheric lead pollution history

    Energy Technology Data Exchange (ETDEWEB)

    Renberg, I.; Braennvall, M.-L.; Bindler, R. [Department of Ecology and Environmental Science, Umea University, SE-901 87 Umea (Sweden); Emteryd, O. [Department of Forest Ecology, Swedish University of Agricultural Sciences, SE-901 83 Umea (Sweden)

    2002-06-20

    Analysis of stable lead isotopes and lead concentrations in lake-sediment deposits, not least in varved (annually-laminated) sediments, is a useful method to study lead pollution history. This paper presents details from a study of 31 lakes in Sweden. Using a strong acid digestion of sediment samples and ICP-MS analyses, we have found that Swedish lake sediments have a high natural (pre-pollution) 206[Pb]/207[Pb] ratio (mean 1.52{+-}0.18, range 1.28-2.01, n=31 lakes). In contrast, atmospheric lead pollution derived from metal smelting processes, coal burning and from alkyl-lead added to petrol has a lower ratio (<1.2). Consequently, when pollution lead deposition began approximately 3500 years ago, the lead isotope ratio of the sediments started to decline, and in modern sediments it is typically <1.2. Using the isotope and concentration values and a mixing model, the relative contribution of pollution and natural lead in sediment samples can be calculated. The pollution lead records of the Swedish lake sediments show a consistent picture of the atmospheric lead pollution history. Some noticeable features are the Roman peak, the large and permanent Medieval increase, peaks at approximately 1200 and 1530 ad, the rapid increase after World War II, the peak in the 1970s, and the large modern decline.

  18. Leading men

    DEFF Research Database (Denmark)

    Bekker-Nielsen, Tønnes

    2016-01-01

    Through a systematic comparison of c. 50 careers leading to the koinarchate or high priesthood of Asia, Bithynia, Galatia, Lycia, Macedonia and coastal Pontus, as described in funeral or honorary inscriptions of individual koinarchs, it is possible to identify common denominators but also disting...

  19. Features of an emergency heat-conducting path in reactors about lead-bismuth and lead heat-carriers

    International Nuclear Information System (INIS)

    Beznosov, A.V.; Bokova, T.A.; Molodtsov, A.A.

    2006-01-01

    The reactor emergency heat removal systems should transfer heat from the surface of reactor core fuel element claddings to the primary circuit followed by heat transfer to the environment. One suggests three design approaches for emergency heat removal systems in lead-bismuth and lead cooled reactor circuits that take account of the peculiar nature of their features. Application of the discussed systems for emergency heat removal improves safety of lead-bismuth and lead cooled reactor plants [ru

  20. Chronic lead intoxication in calves

    Energy Technology Data Exchange (ETDEWEB)

    Wagenaar, G

    1963-01-01

    Four calves born in the winter of 1961-1962 died on a farm after a disease which had run its course for periods ranging from six weeks to a few months. A calf had also died showing similar symptoms during the previous year. All calves showed identical symptoms. Initially, their liveliness diminished; subsequently, they drank less and showed signs of pica. They finally died after the disease had run its course for about six weeks. The last calf, born late in February 1962, was in poor health as early as May, improved slightly when it had been sent out to grass but died in September, having fallen ill again in August. Autopsy was performed on three calves; all three were affected with chronic interstitial nephritis and uraemic endocarditis of the left auricle was present as well. The results obtained on toxicological investigation were indicative of lead poisoning. The liver of the calf was found to contain two mg of lead per kg, the cortex of the kidney containing twenty-five mg of lead per kg. These figures did not provide direct evidence of lead poisoning, but in evaluating these figures the fact was taken into account that the calf had no longer been able to ingest any lead for several months. Meanwhile, it was found that the stock-owner had fitted an old painted door in the calf-shed, which door was constantly being licked by the calves. The paint contained 18.6% of lead. This finding was followed by examination of the liver of a calf that had died previously. It was found to contain 49.7 mg of lead per kg. Accordingly, the calves had been affected with a form of lead poisoning running a relatively slow course, as a result of which the animals had developed chronic interstitial nephritis. The calves eventually died from uraemia. 4 references.

  1. Prospective evaluation of cinefluoroscopy and chest radiography for Riata lead defects: implications for future lead screening.

    Science.gov (United States)

    Lorvidhaya, Peem; Mendoza, Ivan; Sehli, Sharmila; Atalay, Michael K; Kim, Michael H

    2013-11-01

    Lead insulation defects with externalization of the conductors exist in Riata defibrillator leads. Cinefluoroscopy is currently the gold standard to detect such defects. Prospective evaluation of alternative screening options such as chest radiography (CXR), which has been recommended by the FDA, is not well described. Patients with Riata leads underwent cinefluoroscopy, CXR, and device interrogation. Leads were classified as abnormal (clear cable separation), borderline, or normal by independent evaluation of cinefluoroscopy and CXR. CXR evaluation was done in two ways as follows: (1) routine CXR read by daily staff radiologists for lead screening and (2) CXR evaluation by a radiologist educated about the lead defect. One hundred two patients were evaluated at our institution. Cinefluoroscopy showed externalized conductors in 33 patients (32 %). Twenty-five of 33 patients (76 %) who had abnormal cinefluoroscopic findings had abnormal CXR findings on blinded review by the educated radiologist. All 25 patients with abnormal CXR had abnormal findings on cinefluoroscopy. Daily staff radiologists without direct education other than prompts for lead screening detected CXR abnormalities in only 8 out of 102 (8 %) cases. Cinefluoroscopy appears to be more sensitive than CXR for the detection of Riata cable extrusion. Interpretation of CXR by a radiologist with education in lead defects correlates highly with cinefluoroscopy with very high specificity. Depending on available resources for screening, CXR may be a reasonable alternative to cinefluoroscopy. Multidisciplinary collaboration across specialties (radiology and electrophysiology) can lead to improved diagnostic capability and thus the potential for enhanced quality of care.

  2. Remediation of lead from lead electroplating industrial effluent using sago waste.

    Science.gov (United States)

    Jeyanthi, G P; Shanthi, G

    2007-01-01

    Heavy metals are known toxicants, which inflict acute disorders to the living beings. Electroplating industries pose great threat to the environment through heavy load of metals in the wastewater discharged on land and water sources. In the present study, sago processing waste, which is both a waste and a pollutant, was used to adsorb lead ions from lead electroplating industrial effluent. Two types of sago wastes, namely, coarse sago waste and fine sago waste were used to study their adsorption capacity with the batch adsorption and Freundlich adsorption isotherm. The parameters that were considered for batch adsorption were pH (4, 5 and 6), time of contact (1, 2 and 3 hrs), temperature (30, 37 and 45 degrees C) and dosage of the adsorbent (2,4 and 6 g/L). The optimal condition for the effective removal of lead was found to be pH 5, time of contact 3 hrs, temperature 30 degrees C and dosage 4 g/L with coarse sago waste than fine sago waste.

  3. Association of tibia lead and blood lead with end-stage renal disease: A pilot study of African-Americans

    International Nuclear Information System (INIS)

    Muntner, Paul; Menke, Andy; Batuman, Vecihi; Rabito, Felicia A.; He Jiang; Todd, Andrew C.

    2007-01-01

    The association between body lead burden and kidney disease remains controversial. Fifty-five African-American end-stage renal disease (ESRD) cases and 53 age- and sex-matched African-American controls without known renal disease were recruited from Tulane University-affiliated dialysis clinics and out-patient clinics, respectively. Blood lead was measured via atomic absorption spectrophotometry and tibia lead (a measure of body lead) was measured via 109 Cd-based K shell X-ray fluorescence. Median blood lead levels were significantly higher among ESRD cases (6 μg/dL) compared to their control counterparts (3 μg/dL; P<0.001). Although no participants had overt lead poisoning (blood lead ≥25 μg/dL), seven cases but no controls had blood lead levels above 10 μg/dL (P=0.006). The median tibia lead level was 17 micrograms of lead per gram of bone mineral (μg/g) and 13 μg/g among ESRD cases and their control counterparts, respectively (P=0.134). Four ESRD cases (7%), but no controls, had a tibia lead level above 40 μg/g (P=0.115) while a similar proportion of cases and controls had tibia lead between 20 and 39 μg/g (33% and 32%, respectively; P=0.726). After adjustment for potential confounders, the odds ratios of ESRD associated with a tibia lead ≥20 μg/g and each four-fold higher tibia lead (e.g., 5-20 μg/g) were 1.55 (95% CI: 0.55, 4.41) and 1.88 (95% CI: 0.53, 6.68), respectively. These findings support the need for prospective cohort studies of body lead burden and renal disease progression

  4. Effect of lead pollution control on environmental and childhood blood lead level in Nantong, China: an interventional study.

    Science.gov (United States)

    Chen, Kai; Huang, Lei; Yan, Beizhan; Li, Hongbo; Sun, Hong; Bi, Jun

    2014-11-04

    Children's blood lead levels and prevalence of lead poisoning in China are significantly higher than in developed countries, though a substantial decrease has been observed. Since 2011, strict lead control policies in lead-related industries have been implemented in China, but the success of these policies is unknown. In this study, we collected environmental samples, questionnaire data, and blood samples from 106 children from 1 to 14 years old, before and after implementation of lead-usage control policy in wire rope factories by local government in Zhuhang, Nantong in 2012. Results showed that, one year after the lead control, lead concentrations sharply decreased in both environmental and biological samples with a decrease of 0.43 μg/m3 (-84.3%) in ambient air samples, 0.22 mg/kg (-36.1%) in vegetable samples, 441.1 mg/kg (-43.7%) in dust samples, and 6.24 μg/dL (-51.5%) in childhood blood lead levels (BLL). This study demonstrates the success of lead control policies in promoting the prevention and control of childhood lead poisoning in Nantong, China.

  5. Optimization of the precordial leads of the 12-lead electrocardiogram may improve detection of ST-segment elevation myocardial infarction.

    Science.gov (United States)

    Scott, Peter J; Navarro, Cesar; Stevenson, Mike; Murphy, John C; Bennett, Johan R; Owens, Colum; Hamilton, Andrew; Manoharan, Ganesh; Adgey, A A Jennifer

    2011-01-01

    For the assessment of patients with chest pain, the 12-lead electrocardiogram (ECG) is the initial investigation. Major management decisions are based on the ECG findings, both for attempted coronary artery revascularization and risk stratification. The aim of this study was to determine if the current 6 precordial leads (V(1)-V(6)) are optimally located for the detection of ST-segment elevation in ST-segment elevation myocardial infarction (STEMI). We analyzed 528 (38% anterior [200], 44% inferior [233], and 18% lateral [95]) patients with STEMI with both a 12-lead ECG and an 80-lead body surface map (BSM) ECG (Prime ECG, Heartscape Technologies, Bangor, Northern Ireland). Body surface map was recorded within 15 minutes of the 12-lead ECG during the acute event and before revascularization. ST-segment elevation of each lead on the BSM was compared with the corresponding 12-lead precordial leads (V(1)-V(6)) for anterior STEMI. In addition, for lateral STEMI, leads I and aVL of the BSM were also compared; and limb leads II, III, aVF of the BSM were compared with inferior unipolar BSM leads for inferior STEMI. Leads with the greatest mean ST-segment elevation were selected, and significance was determined by analysis of variance of the mean ST segment. For anterior STEMI, leads V(1), V(2), 32, 42, 51, and 57 had the greatest mean ST elevation. These leads are located in the same horizontal plane as that of V(1) and V(2). Lead 32 had a significantly greater mean ST elevation than the corresponding precordial lead V(3) (P = .012); and leads 42, 51, and 57 were also significantly greater than corresponding leads V(4), V(5), V(6), respectively (P mean ST-segment elevation; and lead III was significantly superior to the inferior unipolar leads (7, 17, 27, 37, 47, 55, and 61) of the BSM (P optimal placement for the diagnosis of anterior and lateral STEMI and appear superior to leads V(3), V(4), V(5), and V(6). This is of significant clinical interest, not only for ease and

  6. Leading healthcare in complexity.

    Science.gov (United States)

    Cohn, Jeffrey

    2014-12-01

    Healthcare institutions and providers are in complexity. Networks of interconnections from relationships and technology create conditions in which interdependencies and non-linear dynamics lead to surprising, unpredictable outcomes. Previous effective approaches to leadership, focusing on top-down bureaucratic methods, are no longer effective. Leading in complexity requires leaders to accept the complexity, create an adaptive space in which innovation and creativity can flourish and then integrate the successful practices that emerge into the formal organizational structure. Several methods for doing adaptive space work will be discussed. Readers will be able to contrast traditional leadership approaches with leading in complexity. They will learn new behaviours that are required of complexity leaders, along with challenges they will face, often from other leaders within the organization.

  7. Blood Lead Levels and Risk Factors among Preschool Children in a Lead Polluted Area in Taizhou, China

    Directory of Open Access Journals (Sweden)

    Zhenyan Gao

    2017-01-01

    Full Text Available Objective. To determine the blood lead levels and identify related risk factors among preschool children in a lead polluted area (Taizhou, China and provide theoretical support for prevention of lead pollution. Methods. A stratified-clustered-random sampling method was used to determine the survey sample. Blood lead levels were determined by the tungsten atomizer absorption spectrophotometer. Results. A total of 2,018 subjects (average age of 59 months; 1,087 boys and 931 girls were included. The arithmetic mean, geometric mean, and median blood lead levels of the preschool children were 56.4 μg/L, 48.9 μg/L, and 46 μg/L. A total of 8.8% children had blood lead levels >100 μg/L and 43.9% had blood lead levels >50 μg/L. Mother’s education level, father’s occupation, decorative tableware, exposure to makeup, and the residential floor were all risk factors for elevated blood lead levels (odds ratios of 1.42, 1.21, 1.11, 1.19, and 1.27, resp., while hand washing before eating food was a protective factor (odds ratio of 0.88. Conclusions. The blood lead levels of preschool children in Taizhou were higher than in other areas in China and in developed countries. Therefore, policies ensuring lead-based industries are not placed in close proximity to residential areas are required.

  8. New, dense, and fast scintillators based on rare-earth tantalo-niobates

    International Nuclear Information System (INIS)

    Voloshyna, O.V.; Boiaryntseva, I.A.; Baumer, V.N.; Ivanov, A.I.; Korjik, M.V.; Sidletskiy, O.Ts.

    2014-01-01

    Samples of undoped yttrium and gadolinium tantalo-niobates with common formulae RE(Nb x Ta 1−x )O 4 , where RE=Y or Gd and x=0–1, have been obtained by solid-state reaction. Systematic study of structural, luminescent, and scintillation properties of these compounds was carried out. Lattice parameters and space groups of the mixed compounds were identified. UV- and X-ray luminescence spectra, as well as relative light outputs and scintillation decay times are measured. Gadolinium tantalo-niobate with the formulae GdNb 0.2 Ta 0.8 O 4 showed the light output around 13 times larger than PbWO 4 and fast decay with time constant 12 ns without additional slow component. Gadolinium tantalo-niobates may be considered as promising materials for high energy physics due to extremely high density, substantial light output, and fast decay. -- Highlights: •Structural, optical and scintillation properties of the rare earth tantalo-niobates were studied. •Light output shows about gradual increase with Nb content in GdTa x Nb 1−x O 4 . •Light output increases by 2–7 times relatively to yttrium tantalate and niobate in YTa x Nb 1−x O 4 . •GdTa 0.8 Nb 0.2 O 4 demonstrates the most promising scintillation parameters

  9. Lead (Pb) isotopic fingerprinting and its applications in lead pollution studies in China: a review.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan

    2010-05-01

    As the most widely scattered toxic metal in the world, the sources of lead (Pb) observed in contamination investigation are often difficult to identify. This review presents an overview of the principles, analysis, and applications of Pb isotopic fingerprinting in tracing the origins and transport pathways of Pb in the environment. It also summarizes the history and current status of lead pollution in China, and illustrates the power of Pb isotopic fingerprinting with examples of its recent applications in investigating the effectiveness of leaded gasoline phase-out on atmospheric lead pollution, and the sources of Pb found in various environmental media (plants, sediments, and aquatic organisms) in China. The limitations of Pb isotopic fingerprinting technique are discussed and a perspective on its development is also presented. Further methodological developments and more widespread instrument availability are expected to make isotopic fingerprinting one of the key tools in lead pollution investigation. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. The Role of Magnesium in Neurological Disorders

    Directory of Open Access Journals (Sweden)

    Anna E. Kirkland

    2018-06-01

    Full Text Available Magnesium is well known for its diverse actions within the human body. From a neurological standpoint, magnesium plays an essential role in nerve transmission and neuromuscular conduction. It also functions in a protective role against excessive excitation that can lead to neuronal cell death (excitotoxicity, and has been implicated in multiple neurological disorders. Due to these important functions within the nervous system, magnesium is a mineral of intense interest for the potential prevention and treatment of neurological disorders. Current literature is reviewed for migraine, chronic pain, epilepsy, Alzheimer’s, Parkinson’s, and stroke, as well as the commonly comorbid conditions of anxiety and depression. Previous reviews and meta-analyses are used to set the scene for magnesium research across neurological conditions, while current research is reviewed in greater detail to update the literature and demonstrate the progress (or lack thereof in the field. There is strong data to suggest a role for magnesium in migraine and depression, and emerging data to suggest a protective effect of magnesium for chronic pain, anxiety, and stroke. More research is needed on magnesium as an adjunct treatment in epilepsy, and to further clarify its role in Alzheimer’s and Parkinson’s. Overall, the mechanistic attributes of magnesium in neurological diseases connote the macromineral as a potential target for neurological disease prevention and treatment.

  11. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT...

  12. Significance of Lead Residues in Mallard Tissues

    Science.gov (United States)

    Longcore, J.R.; Locke, L.N.; Bagley, George E.; Andrews, R.

    1974-01-01

    Tissues of adult, lead-dosed mallards that either died or were sacrificed were analyzed for lead. Lead levels in brains, tibiae, and breast muscle of ducks that died and in tibiae of ducks that were sacrificed increased significantly from dosage until death. Lead in the heart, lung, and blood from sacrificed ducks decreased significantly from dosage until death. Lead concentrations in tissues from ducks in the two groups were not significantly different except for the liver, kidney, and lung. Average lead levels in the livers and kidneys of ducks that died were significantly higher than those in ducks that were sacrificed. The mean concentration of lead in the lungs of the ducks sacrificed was significantly higher than the mean level in the lungs of ducks that died. Measurements of the lead concentrations in this study, when compared with lead levels reported in the literature for avian and non-avian species, showed that arbitrary diagnostic levels indicating lead poisoning could be set. In mallard ducks, lead levels exceeding 3 ppm in the brain, 6 to 20 ppm in the kidney or liver, or 10 ppm in clotted blood from the heart indicated acute exposure to lead.

  13. Contaminated lead environments of man: reviewing the lead isotopic evidence in sediments, peat, and soils for the temporal and spatial patterns of atmospheric lead pollution in Sweden.

    Science.gov (United States)

    Bindler, Richard

    2011-08-01

    Clair Patterson and colleagues demonstrated already four decades ago that the lead cycle was greatly altered on a global scale by humans. Moreover, this change occurred long before the implementation of monitoring programs designed to study lead and other trace metals. Patterson and colleagues also developed stable lead isotope analyses as a tool to differentiate between natural and pollution-derived lead. Since then, stable isotope analyses of sediment, peat, herbaria collections, soils, and forest plants have given us new insights into lead biogeochemical cycling in space and time. Three important conclusions from our studies of lead in the Swedish environment conducted over the past 15 years, which are well supported by extensive results from elsewhere in Europe and in North America, are: (1) lead deposition rates at sites removed from major point sources during the twentieth century were about 1,000 times higher than natural background deposition rates a few thousand years ago (~10 mg Pb m(-2) year(-1) vs. 0.01 mg Pb m(-2) year(-1)), and even today (~1 mg Pb m(-2) year(-1)) are still almost 100 times greater than natural rates. This increase from natural background to maximum fluxes is similar to estimated changes in body burdens of lead from ancient times to the twentieth century. (2) Stable lead isotopes ((206)Pb/(207)Pb ratios shown in this paper) are an effective tool to distinguish anthropogenic lead from the natural lead present in sediments, peat, and soils for both the majority of sites receiving diffuse inputs from long range and regional sources and for sites in close proximity to point sources. In sediments >3,500 years and in the parent soil material of the C-horizon, (206)Pb/(207)Pb ratios are higher, 1.3 to >2.0, whereas pollution sources and surface soils and peat have lower ratios that have been in the range 1.14-1.18. (3) Using stable lead isotopes, we have estimated that in southern Sweden the cumulative anthropogenic burden of

  14. Photovoltaic effect and photopolarization in Pb [(Mg1/3Nb2/3) 0.68Ti0.32] O3 crystal

    Science.gov (United States)

    Makhort, A. S.; Chevrier, F.; Kundys, D.; Doudin, B.; Kundys, B.

    2018-01-01

    Ferroelectric materials are an alternative to semiconductor-based photovoltaics and offer the advantage of above bandgap photovoltage generation. However, there are few known compounds, and photovoltaic efficiencies remain low. Here, we report the discovery of a photovoltaic effect in undoped lead magnesium niobate-lead titanate crystal and a significant improvement in the photovoltaic response under suitable electric fields and temperatures. The photovoltaic effect is maximum near the electric-field-driven ferroelectric dipole reorientation, and increases threefold near the Curie temperature (Tc). Moreover, at ferroelectric saturation, the photovoltaic response exhibits clear remanent and transient effects. The transient-remanent combinations together with electric and thermal tuning possibilities indicate photoferroelectric crystals as emerging elements for photovoltaics and optoelectronics, relevant to all-optical information storage and beyond.

  15. An exploratory study of lead recovery in lead-acid battery lifecycle in US market: An evidence-based approach

    International Nuclear Information System (INIS)

    Genaidy, A.M.; Sequeira, R.; Tolaymat, T.; Kohler, J.; Rinder, M.

    2008-01-01

    Background: This research examines lead recovery and recycling in lead-acid batteries (LAB) which account for 88% of US lead consumption. We explore strategies to maximize lead recovery and recycling in the LAB lifecycle. Currently, there is limited information on recycling rates for LAB in the published literature and is derived from a single source. Therefore, its recycling efforts in the US has been unclear so as to determine the maximum opportunities for metal recovery and recycling in the face of significant demands for LAB particularly in the auto industry. Objectives: The research utilizes an evidence-based approach to: (1) determine recycling rates for lead recovery in the LAB product lifecycle for the US market; and (2) quantify and identify opportunities where lead recovery and recycling can be improved. Methods: A comprehensive electronic search of the published literature was conducted to gather information on different LAB recycling models and actual data used to calculate recycling rates based on product lifecycle for the US market to identify strategies for increasing lead recovery and recycling. Results: The electronic search yielded five models for calculating LAB recycling rates. The description of evidence was documented for each model. Furthermore, an integrated model was developed to identify and quantify the maximum opportunities for lead recovery and recycling. Results showed that recycling rates declined during the period spanning from 1999 to 2006. Opportunities were identified for recovery and recycling of lead in the LAB product lifecycle. Concluding remarks: One can deduce the following from the analyses undertaken in this report: (1) lead recovery and recycling has been stable between 1999 and 2006; (2) lead consumption has increased at an annual rate of 2.25%, thus, the values derived in this study for opportunities dealing with lead recovery and recycling underestimate the amount of lead in scrap and waste generated; and (3) the

  16. Skin toxicology of lead species evaluated by their permeability and proteomic profiles: a comparison of organic and inorganic lead.

    Science.gov (United States)

    Pan, Tai-Long; Wang, Pei-Wen; Al-Suwayeh, Saleh A; Chen, Chih-Chieh; Fang, Jia-You

    2010-08-01

    Lead compounds are known to cause cytotoxicity and genotoxicity. Lead absorption by the skin is an important route through which this metal enters the body. The purpose of this work was to evaluate the skin permeability and toxicological profiles of two lead species, lead acetate and lead nitrate. This study assessed lead-induced toxicity mechanisms by focusing on the histopathology, proteomics, cell growth, and cellular ATP. In vitro skin permeation assays showed that there was no significant difference of lead accumulation within and across the skin between the two lead species. The presence of simulated sweat reduced the skin uptake of lead. The skin deposition of lead acetate was greater than that of lead nitrate with in vivo topical application. On the other hand, lead nitrate produced greater changes in the skin's histology and proteomic profiles compared to lead acetate. Four protein spots which showed significant changes were identified and are discussed in this study. These included glucose-related protein precursor (GRP) 78, K14, alpha-actin, and Rho GDP-dissociation inhibitor 2 (RhoGDI2). These proteins are respectively associated with oxidative stress, apoptosis, wound healing, and proliferation. Lead presented a biphasic pattern on cell growth and intracellular ATP content, with a stimulating effect at low concentrations and an inhibitory effect on cell proliferation at higher concentrations. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Occurrence and determinants of increases in blood lead levels in children shortly after lead hazard control activities

    International Nuclear Information System (INIS)

    Clark, Scott; Grote, JoAnn; Wilson, Jonathan; Succop, Paul; Chen Mei; Galke, Warren; McLaine, Pat

    2004-01-01

    This study is an examination of the effect of lead hazard control strategies on children's blood lead levels immediately after an intervention was conducted as part of the US Department of Housing and Urban Development's Lead-Based Paint Hazard Control Grant Program. Fourteen state and local government grantees participated in the evaluation. The findings indicated an overall average reduction in the blood lead levels of 869 children soon after the implementation of lead hazard controls. However, 9.3% of these children (n=81) had blood lead increases of 5 μg/dL or more. Data routinely collected as part of the evaluation, as well as additional information supplied by the individual programs, were used to determine potential reasons for these observed increases in blood lead. A logistic regression analysis indicated that three principal factors were associated with the blood lead increases: the number of exterior deteriorations present in the child's home (prior to intervention), the educational level of the female parent or guardian of the child, and the child's age. The statistical analysis did not find evidence that children living in households that either did not relocate or relocated for less than the full work period were significantly more likely to have a blood lead increase equal to or greater than 5 μg/dL than children living in households that fully relocated. Statistical analyses also did not reveal any single interior strategy to be more or less likely than others to be associated with a blood lead increase of 5 μg/dL or more

  18. Lead level in mallard (Anas platyrhynchos

    Directory of Open Access Journals (Sweden)

    Ioan Macinic

    2012-12-01

    Full Text Available The study was carried out on a hunting ground belonging to AJVPS Arad, county Arad. Lead (Pb was determined in Mallard (Anas platyrhynchos tissues (muscles and organs (liver, kidneys to see the contamination level of this tissues and organs and also the impact on humans health because in our days more and more wild game meat take a increasing percentage in humans food ratio. The Mallard is one of the most widespread duck species. Mallard has 50-62 cm length, 800-1400 g weight and lives about 11 years. It prefers rivers and shallow pounds with a lot of reed. It is a migratory species that is flying long distances to find food and unfrozen water, so it is a exposed to lead contamination that is under dust form in atmosphere. But another reason why lead level in Mallard can be higher that in other flying specie (pheasant, woodcock, quail, and pigeons are the lead shot shells that are used for duck hunting. It is known that the ducks can ingest these lead shot shells and so they are often exposed to lead intoxications. This is why in our days more ammunition for waterfowl are steel made or different type of alloys. Lead is known to be one of the most common pollutants with a large range of effects on human health: lead affects nervous system, digestive tract, kidneys, bones, enzymes. Lead has also mutagenic effect, carcinogenic effect, teratogenic effect.

  19. Investigation and Evaluation of Children’s Blood Lead Levels around a Lead Battery Factory and Influencing Factors

    Directory of Open Access Journals (Sweden)

    Feng Zhang

    2016-05-01

    Full Text Available Lead pollution incidents have occurred frequently in mainland China, which has caused many lead poisoning incidents. This paper took a battery recycling factory as the subject, and focused on measuring the blood lead levels of environmental samples and all the children living around the factory, and analyzed the relationship between them. We collected blood samples from the surrounding residential area, as well as soil, water, vegetables. The atomic absorption method was applied to measure the lead content in these samples. The basic information of the generation procedure, operation type, habit and personal protect equipment was collected by an occupational hygiene investigation. Blood lead levels in 43.12% of the subjects exceeded 100 μg/L. The 50th and the 95th percentiles were 89 μg/L and 232 μg/L for blood lead levels in children, respectively, and the geometric mean was 94 μg/L. Children were stratified into groups by age, gender, parents’ occupation, distance and direction from the recycling plant. The difference of blood lead levels between groups was significant (p < 0.05. Four risk factors for elevated blood lead levels were found by logistic regression analysis, including younger age, male, shorter distance from the recycling plant, and parents with at least one working in the recycling plant. The rate of excess lead concentration in water was 6.25%, 6.06% in soil and 44.44% in leaf vegetables, which were all higher than the Chinese environment standards. The shorter the distance to the factory, the higher the value of BLL and lead levels in vegetable and environment samples. The lead level in the environmental samples was higher downwind of the recycling plant.

  20. Detection of lead nanoparticles in game meat by single particle ICP-MS following use of lead-containing bullets.

    Science.gov (United States)

    Kollander, Barbro; Widemo, Fredrik; Ågren, Erik; Larsen, Erik H; Loeschner, Katrin

    2017-03-01

    This study investigated whether game meat may contain nanoparticles of lead from ammunition. Lead nanoparticles in the range 40 to 750 nm were detected by ICP-MS in single particle mode in game shot with lead-containing bullets. The median diameter of the detected nanoparticles was around 60 nm. The particle mass concentration ranged from 290 to 340 ng/g meat and the particle number concentrations from 27 to 50 million particles/g meat. The size limit of detection strongly depended on the level of dissolved lead and was in the range of 40 to 80 nm. In game meat sampled more than 10 cm away from the wound channel, no lead particles with a diameter larger than 40 nm were detected. In addition to dissolved lead in meat that originated from particulates, the presence of lead nano particles in game meat represents a hitherto unattended source of lead with a largely unknown toxicological impact to humans. Graphical Abstract Detection of lead nanoparticles in game meat by single particle ICP-MS following use of leadcontaining bullets.

  1. Apparatus and methods for purifying lead

    Science.gov (United States)

    Tunison, Harmon M.

    2016-01-12

    Disclosed is an exemplary method of purifying lead which includes the steps of placing lead and a fluoride salt blend in a container; forming a first fluid of molten lead at a first temperature; forming a second fluid of the molten fluoride salt blend at a second temperature higher than the first temperature; mixing the first fluid and the second fluid together; separating the two fluids; solidifying the molten fluoride salt blend at a temperature above a melting point of the lead; and removing the molten lead from the container. In certain exemplary methods the molten lead is removed from the container by decanting. In still other exemplary methods the molten salt blend is a Lewis base fluoride eutectic salt blend, and in yet other exemplary methods the molten salt blend contains sodium fluoride, lithium fluoride, and potassium fluoride.

  2. 75 FR 35086 - Magnesium From China and Russia

    Science.gov (United States)

    2010-06-21

    ... China and Russia AGENCY: United States International Trade Commission. ACTION: Notice of Commission... and Russia. SUMMARY: The Commission hereby gives notice that it will proceed with full reviews... revocation of the antidumping duty orders on magnesium from China and Russia would be likely to lead to...

  3. Influence of experimental distemper infection on the distribution of lead in dogs previously subacutely intoxicated with lead carbonate

    Energy Technology Data Exchange (ETDEWEB)

    White, D.J.; Marshall, A.J.; McLeod, S.

    1975-01-01

    The ability of experimental canine distemper infection to mobilize body lead deposits has been studied in Beagle dogs previously subacutely intoxicated with lead carbonate. For comparative purposes dogs were included which had either received lead only or distemper only or remained undosed. It was found that in dogs predosed with lead, distemper infection resulted in a significant increase in lead levels in blood and urine; this coincided with the peak body temperatures reached on the third day post infection. It was also found that the lead content of the liver and bone of these dogs was considerably higher than that of dogs receiving lead alone; at the same time bone phosphorus showed a marked decrease while bone calcium values remained similar to undosed controls.

  4. Toxicity of lead-contaminated sediment to mallards

    Science.gov (United States)

    Heinz, G.H.; Hoffman, D.J.; Sileo, L.; Audet, D.J.; LeCaptain, L.J.

    1999-01-01

    Because consumption of lead-contaminated sediment has been suspected as the cause of waterfowl mortality in the Coeur d?Alene River basin in Idaho, we studied the bioavailability and toxicity of this sediment to mallards (Anas platyrhynchos). In experiment 1, one of 10 adult male mallards died when fed a pelleted commercial duck diet that contained 24% lead-contaminated sediment (with 3,400 μg/g lead in the sediment). Protoporphyrin levels in the blood increased as the percentage of lead-contaminated sediment in the diet increased. Birds fed 24% lead-contaminated sediment exhibited atrophy of the breast muscles, green staining of the feathers around the vent, viscous bile, green staining of the gizzard lining, and renal tubular intranuclear inclusion bodies. Mallards fed 24% lead-contaminated sediment had means of 6.1 μg/g of lead in the blood and 28 μg/g in the liver (wet-weight basis) and 1,660 μg/g in the feces (dry-weight basis). In experiment 2, we raised the dietary concentration of the lead-contaminated sediment to 48%, but only about 20% sediment was actually ingested due to food washing by the birds. Protoporphyrin levels were elevated in the lead-exposed birds, and all of the mallards fed 48% lead-contaminated sediment had renal tubular intranuclear inclusion bodies. The concentrations of lead in the liver were 9.1 μg/g for mallards fed 24% lead-contaminated sediment and 16 μg/g for mallards fed 48% lead-contaminated sediment. In experiment 3, four of five mallards died when fed a ground corn diet containing 24% lead-contaminated sediment (with 4,000 μg/g lead in this sample of sediment), but none died when the 24% lead-contaminated sediment was mixed into a nutritionally balanced commercial duck diet; estimated actual ingestion rates for sediment were 14% and 17% for the corn and commercial diets. Lead exposure caused elevations in protoporphyrin, and four of the five mallards fed 24% lead-contaminated sediment in a commercial diet and all five

  5. 76 FR 69284 - Pure Magnesium From China

    Science.gov (United States)

    2011-11-08

    ... China Determination On the basis of the record \\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the...), entitled Pure Magnesium from China: Investigation No. 731-TA-696 (Third Review). Issued: November 2, 2011...

  6. 40 CFR 52.58 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985, and...

  7. Neurobehavioural effects of occupational exposure to lead.

    Science.gov (United States)

    Williamson, A M; Teo, R K

    1986-06-01

    A set of neurobehavioural tests selected on the basis of information processing theory was used to study the effect of low level occupational lead exposure on 59 lead workers compared with a matched control group of the same number. Only one of the lead exposed group had a blood lead concentration above the current threshold limit value of 3.81 mumol/l at the time of testing (mean 2.36 mumol/l, range 1.19-3.92 mumol/l) and none had been detected above that level in the previous three years. Nevertheless, most neurobehavioural functions tested showed some impairment in the lead workers. Visual sensory function was affected and, perhaps as a consequence, sustained attention and psychomotor tasks were performed more slowly by the lead exposed group. Cognitive functions were also impaired, with sensory store memory, short term memory, and learning abilities all showing deficits in lead workers. Such cognitive deficits may also be partly due to initial degradation of the visual input. Long term memory performance compared equally with control levels possibly because of development of a compensatory strategy such as rehearsal by the lead exposed subjects. Multiple linear regression analysis relating to lead workers test performance and their lead exposure showed that performance on the sensory store memory test alone was significantly related to exposure. This was probably due to the homogeneity of the lead exposed group with regard to blood lead concentrations and the use of blood lead as a measure of chronic lead exposure.

  8. Neurobehavioural effects of occupational exposure to lead

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, A.M.; Teo, R.K.

    1986-06-01

    A set of neurobehavioural tests selected on the basis of information processing theory was used to study the effect of low level occupational lead exposure on 59 lead workers compared with a matched control group of the same number. Only one of the lead exposed group had a blood lead concentration above the current threshold limit value of 3.81 mumol/l at the time of testing (mean 2.36 mumol/l, range 1.19-3.92 mumol/l) and none had been detected above that level in the previous three years. Nevertheless, most neurobehavioural functions tested showed some impairment in the lead workers. Visual sensory function was affected and, perhaps as a consequence, sustained attention and psychomotor tasks were performed more slowly by the lead exposed group. Cognitive functions were also impaired, with sensory store memory, short term memory, and learning abilities all showing deficits in lead workers. Such cognitive deficits may also be partly due to initial degradation of the visual input. Long term memory performance compared equally with control levels possibly because of development of a compensatory strategy such as rehearsal by the lead exposed subjects. Multiple linear regression analysis relating to lead workers test performance and their lead exposure showed that performance on the sensory store memory test alone was significantly related to exposure. This was probably due to the homogeneity of the lead exposed group with regard to blood lead concentrations and the use of blood lead as a measure of chronic lead exposure.

  9. Lightweight, durable lead-acid batteries

    Science.gov (United States)

    Lara-Curzio, Edgar; An, Ke; Kiggans, Jr., James O; Dudney, Nancy J; Contescu, Cristian I; Baker, Frederick S; Armstrong, Beth L

    2013-05-21

    A lightweight, durable lead-acid battery is disclosed. Alternative electrode materials and configurations are used to reduce weight, to increase material utilization and to extend service life. The electrode can include a current collector having a buffer layer in contact with the current collector and an electrochemically active material in contact with the buffer layer. In one form, the buffer layer includes a carbide, and the current collector includes carbon fibers having the buffer layer. The buffer layer can include a carbide and/or a noble metal selected from of gold, silver, tantalum, platinum, palladium and rhodium. When the electrode is to be used in a lead-acid battery, the electrochemically active material is selected from metallic lead (for a negative electrode) or lead peroxide (for a positive electrode).

  10. Childhood Blood Lead Reductions Following Removal of Leaded Ceramic Glazes in Artisanal Pottery Production: A Success Story

    OpenAIRE

    Donald E. Jones, MS; Mario Covarrubias Pérez; Bret Ericson; Daniel Estrada Sánchez; Sandra Gualtero; Andrea Smith-Jones, MS; Jack Caravanos, DrPH, CIH

    2013-01-01

    Background. Lead exposure within artisanal ceramics workshop communities in Mexico continues to be a major source of childhood lead poisoning. Artisanal ceramics workshops expose children through direct ingestion, contaminated soil, and food prepared in lead-glazed pottery. Conversion to non-lead glazes alone may not effectively reduce exposure. This paper describes a model comprehensive intervention and environmental remediation of an artisanal ceramics workshop in the state of Hidalgo, Mexi...

  11. Structural features of epitaxial NiFe2O4 thin films grown on different substrates by direct liquid injection chemical vapor deposition

    Science.gov (United States)

    Datta, R.; Loukya, B.; Li, N.; Gupta, A.

    2012-04-01

    NiFe2O4 (NFO) thin films are grown on four different substrates, i.e., Lead Zinc Niobate-Lead Titanate (PZN-PT), Lead Magnesium Niobate-Lead Titanate (PMN-PT), MgAl2O4 (MAO) and SrTiO3 (STO), by a direct liquid injection chemical vapor deposition technique (DLI-CVD) under optimum growth conditions where relatively high growth rate (˜20 nm/min), smooth surface morphology and high saturation magnetization values in the range of 260-290 emu/ cm3 are obtained. The NFO films with correct stoichiometry (Ni:Fe=1:2) grow epitaxially on all four substrates, as confirmed by energy dispersive X-ray spectroscopy, transmission electron microscopy and x-ray diffraction. While the films on PMN-PT and PZN-PT substrates are partially strained, essentially complete strain relaxation occurs for films grown on MAO and STO. The formations of threading dislocations along with dark diffused contrast areas related to antiphase domains having a different cation ordering are observed on all four substrates. These crystal defects are correlated with lattice mismatch between the film and substrate and result in changes in magnetic properties of the films. Atomic resolution HAADF imaging and EDX line profiles show formation of a sharp interface between the film and the substrate with no inter-diffusion of Pb or other elements across the interface. Antiphase domains are observed to originate at the film-substrate interface.

  12. Cumulant generating function formula of heat transfer in ballistic systems with lead-lead coupling

    Science.gov (United States)

    Li, Huanan; Agarwalla, Bijay Kumar; Wang, Jian-Sheng

    2012-10-01

    Based on a two-time observation protocol, we consider heat transfer in a given time interval tM in a lead-junction-lead system taking coupling between the leads into account. In view of the two-time observation, consistency conditions are carefully verified in our specific family of quantum histories. Furthermore, its implication is briefly explored. Then using the nonequilibrium Green's function method, we obtain an exact formula for the cumulant generating function for heat transfer between the two leads, valid in both transient and steady-state regimes. Also, a compact formula for the cumulant generating function in the long-time limit is derived, for which the Gallavotti-Cohen fluctuation symmetry is explicitly verified. In addition, we briefly discuss Di Ventra's repartitioning trick regarding whether the repartitioning procedure of the total Hamiltonian affects the nonequilibrium steady-state current fluctuation. All kinds of properties of nonequilibrium current fluctuations, such as the fluctuation theorem in different time regimes, could be readily given according to these exact formulas.

  13. Incidence of nephrolithiasis in relation to environmental exposure to lead and cadmium in a population study

    Energy Technology Data Exchange (ETDEWEB)

    Hara, Azusa; Yang, Wen-Yi; Petit, Thibault; Zhang, Zhen-Yu; Gu, Yu-Mei; Wei, Fang-Fei; Jacobs, Lotte [Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Leuven (Belgium); Odili, Augustine N. [Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Leuven (Belgium); Department of Internal Medicine, Faculty of Clinical Sciences, College of Health Sciences University of Abuja (Nigeria); Thijs, Lutgarde [Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Leuven (Belgium); Nawrot, Tim S. [Centre for Environmental Sciences, University of Hasselt (Belgium); Staessen, Jan A., E-mail: jan.staessen@med.kuleuven.be [Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Leuven (Belgium); R& D Group VitaK, Maastricht University, Maastricht (Netherlands)

    2016-02-15

    Whether environmental exposure to nephrotoxic agents that potentially interfere with calcium homeostasis, such as lead and cadmium, contribute to the incidence of nephrolithiasis needs further clarification. We investigated the relation between nephrolithiasis incidence and environmental lead and cadmium exposure in a general population. In 1302 participants randomly recruited from a Flemish population (50.9% women; mean age, 47.9 years), we obtained baseline measurements (1985–2005) of blood lead (BPb), blood cadmium (BCd), 24-h urinary cadmium (UCd) and covariables. We monitored the incidence of kidney stones until October 6, 2014. We used Cox regression to calculate multivariable-adjusted hazard ratios for nephrolithiasis. At baseline, geometric mean BPb, BCd and UCd was 0.29 µmol/L, 9.0 nmol/L, and 8.5 nmol per 24 h, respectively. Over 11.5 years (median), nephrolithiasis occurred in 40 people. Contrasting the low and top tertiles of the distributions, the sex- and age-standardized rates of nephrolithiasis expressed as events per 1000 person-years were 0.68 vs. 3.36 (p=0.0016) for BPb, 1.80 vs. 3.28 (p=0.11) for BCd, and 1.65 vs. 2.95 (p=0.28) for UCd. In continuous analysis, with adjustments applied for sex, age, serum magnesium, and 24-h urinary volume and calcium, the hazard ratios expressing the risk associated with a doubling of the exposure biomarkers were 1.35 (p=0.015) for BPb, 1.13 (p=0.22) for BCd, and 1.23 (p=0.070) for UCd. In conclusion, our results suggest that environmental lead exposure is a risk factor for nephrolithiasis in the general population. - Highlights: • Prevalence and incidence rates of nephrolithiasis are increasing worldwide. • Lead and cadmium interfere with calcium homeostasis and might cause nephrolithiasis. • Environmental exposure to lead, not cadmium, predicts nephrolithiasis in the population. • Safety standards for environmental lead exposure need to account for nephrolithiasis. • Reducing environmental

  14. Detection of lead nanoparticles in game meat by single particle ICP-MS following use of lead-containing bullets

    DEFF Research Database (Denmark)

    Kollander, Barbro; Widemo, Fredrik; Ågren, Erik

    2017-01-01

    This study investigated whether game meat may contain nanoparticles of lead from ammunition. Lead nanoparticles in the range 40 to 750 nm were detected by ICP-MS in single particle mode in game shot with lead-containing bullets. The median diameter of the detected nanoparticles was around 60 nm....... The particle mass concentration ranged from 290 to 340 ng/g meat and the particle number concentrations from 27 to 50 million particles/g meat. The size limit of detection strongly depended on the level of dissolved lead and was in the range of 40 to 80 nm. In game meat sampled more than 10 cm away from...... the wound channel, no lead particles with a diameter larger than 40 nm were detected. In addition to dissolved lead in meat that originated from particulates, the presence of lead nano particles in game meat represents a hitherto unattended source of lead with a largely unknown toxicological impact...

  15. Solubility of iron in liquid lead

    International Nuclear Information System (INIS)

    Ali-Khan, I.

    1981-01-01

    The use of liquid lead in high temperature chemical and metallurgical processes is well known. The structural materials applied for the containment of these processes are either iron base alloys or possess iron as an alloying element. Besides that, lead itself is alloyed in some steels to achieve some very useful properties. For understanding the effect of liquid lead in such structural materials, it is important to determine the solubility of iron in liquid lead which would also be indicative of the stability of these alloys. At the institute of reactor materials of KFA Juelich, investigations have been conducted to determine the solubility of iron in liquid lead up to a temperature of about 1000 0 C. In this presentation the data concerning the solubility of iron in liquid lead are brought up to date and discussed including the results of our previous investigations. (orig.)

  16. The effect of the hemochromatosis (HFE) genotype on lead load and iron metabolism among lead smelter workers.

    Science.gov (United States)

    Fan, Guangqin; Du, Guihua; Li, Huijun; Lin, Fen; Sun, Ziyong; Yang, Wei; Feng, Chang; Zhu, Gaochun; Li, Yanshu; Chen, Ying; Jiao, Huan; Zhou, Fankun

    2014-01-01

    Both an excess of toxic lead (Pb) and an essential iron disorder have been implicated in many diseases and public health problems. Iron metabolism genes, such as the hemochromatosis (HFE) gene, have been reported to be modifiers for lead absorption and storage. However, the HFE gene studies among the Asian population with occupationally high lead exposure are lacking. To explore the modifying effects of the HFE genotype (wild-type, H63D variant and C282Y variant) on the Pb load and iron metabolism among Asian Pb-workers with high occupational exposure. Seven hundred and seventy-one employees from a lead smelter manufacturing company were tested to determine their Pb intoxication parameters, iron metabolic indexes and identify the HFE genotype. Descriptive and multivariate analyses were conducted. Forty-five H63D variant carriers and no C282Y variant carrier were found among the 771 subjects. Compared with subjects with the wild-type genotype, H63D variant carriers had higher blood lead levels, even after controlling for factors such as age, sex, marriage, education, smoking and lead exposure levels. Multivariate analyses also showed that the H63D genotype modifies the associations between the blood lead levels and the body iron burden/transferrin. No C282Y variant was found in this Asian population. The H63D genotype modified the association between the lead and iron metabolism such that increased blood lead is associated with a higher body iron content or a lower transferrin in the H63D variant. It is indicated that H63D variant carriers may be a potentially highly vulnerable sub-population if they are exposed to high lead levels occupationally.

  17. Comparative assessment of thermophysical and thermohydraulic characteristics of lead, lead-bismuth and sodium coolants for fast reactors

    International Nuclear Information System (INIS)

    2002-06-01

    All prototype, demonstration and commercial liquid metal cooled fast reactors (LMFRs) have used liquid sodium as a coolant. Sodium cooled systems, operating at low pressure, are characterised by very large thermal margins relative to the coolant boiling temperature and a very low structural material corrosion rate. In spite of the negligible thermal energy stored in the liquid sodium available for release in case of leakage, there is some safety concern because of its chemical reactivity with respect to air and water. Lead, lead-bismuth or other alloys of lead, appear to eliminate these concerns because the chemical reactivity of these coolants with respect to air and water is very low. Some experts believe that conceptually, these systems could be attractive if high corrosion activity inherent in lead, long term materials compatibility and other problems will be resolved. Extensive research and development work is required to meet this goal. Preliminary studies on lead-bismuth and lead cooled reactors and ADS (accelerator driven systems) have been initiated in France, Japan, the United States of America, Italy, and other countries. Considerable experience has been gained in the Russian Federation in the course of development and operation of reactors cooled with lead-bismuth eutectic, in particular, propulsion reactors. Studies on lead cooled fast reactors are also under way in this country. The need to exchange information on alternative fast reactor coolants was a major consideration in the recommendation by the Technical Working Group on Fast Reactors (TWGFRs) to collect, review and document the information on lead and lead-bismuth alloy coolants: technology, thermohydraulics, physical and chemical properties, as well as to make an assessment and comparison with respective sodium characteristics

  18. Acute and chronic lead poisoning in cattle

    Energy Technology Data Exchange (ETDEWEB)

    Iosif, C

    1966-02-01

    Three cases of acute plumbism in cows are detailed: one of a six-year-old cow who accidentally ate about 100 gm. of lead (in 1956); the second of a 12-year-old cow who accidentally ate a packet containing about 100 gm. of lead used in painting; and the third of a three-week-old heifer who licked a freshly painted bucket. Route of exposure to lead can be gastrointestinal following deposition of lead fumes (lead oxide, sulfide, and sulfate) on pasturage and in exposed drinking water, or respiratory following the inhalation of such fumes. The presence of CO/sub 2/ in the respiratory tract is thought to provide a favorable situation for the dissolution of lead and the formation of soluble lead complexes. One author has calculated that 12% of respired lead is absorbed into the organism, while only 1-2% of ingested lead is absorbed.

  19. Lithium niobate ultrasonic transducer design for Enhanced Oil Recovery.

    Science.gov (United States)

    Wang, Zhenjun; Xu, Yuanming; Gu, Yuting

    2015-11-01

    Due to the strong piezoelectric effect possessed by lithium niobate, a new idea that uses lithium niobate to design high-power ultrasonic transducer for Enhanced Oil Recovery technology is proposed. The purpose of this paper is to lay the foundation for the further research and development of high-power ultrasonic oil production technique. The main contents of this paper are as follows: firstly, structure design technique and application of a new high-power ultrasonic transducer are introduced; secondly, the experiment for reducing the viscosity of super heavy oil by this transducer is done, the optimum ultrasonic parameters for reducing the viscosity of super heavy oil are given. Experimental results show that heavy large molecules in super heavy oil can be cracked into light hydrocarbon substances under strong cavitation effect caused by high-intensity ultrasonic wave. Experiment proves that it is indeed feasible to design high-power ultrasonic transducer for ultrasonic oil production technology using lithium niobate. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Lead contamination of paint remediation workers' vehicles.

    Science.gov (United States)

    Boraiko, Carol; Wright, Eva M; Ralston, Faye

    2013-03-01

    Exposure to lead has been shown to be harmful to adults; it is a teratogen, it can damage the peripheral nervous system, and it adversely affects the reproductive system. Professional lead-based paint remediation workers are at risk of exposure to lead dust. The authors' study was conducted to determine if these remediation workers transfer lead from their work site to their vehicles and then potentially expose their families. It was hypothesized that remediation workers transported the lead from the remediation work site to the floorboards of their vehicles due to not following required protective equipment use. The laboratory's level of quantitation for lead on the wipe samples, 10 microg/ft2, was used to indicate lead contamination. This level was exceeded in 50% of the floorboards sampled. These results confirm that many vehicle floorboards used by remediation workers are contaminated with lead dust, potentially resulting in transfer of lead dust. The ultimate detrimental outcome could be the transfer of lead particles to other family members, causing the poisoning of a child or other at-risk person.

  1. Some hallways lead to other hallways and some lead to dead ends

    OpenAIRE

    Tam, Nancy Y.S

    2013-01-01

    Some Hallways Lead To Other Hallways And Some Lead To Dead Ends is a one-hour long synchronized audio tour for ten people. Listening to their assigned tracks played through headphones, the audience is mobilized through the SFU Woodward’s building. The aural content is comprised of choreographic instructions and my personal stories as a third culture kid in finding home. Appendix A is a research paper written for FPA 812, where I examine Henri Lefebvre’s ideas of space and how these ideas are ...

  2. The influence of lead length on the fractures associated with leading corners and sidings

    CSIR Research Space (South Africa)

    Turner, PA

    1989-02-01

    Full Text Available leading and lagging panels was found generally to extend further into the lagging panel with increasing lead length. Curves fitted to the data seem to be asymptotic to a limiting fracture extent of about 15 to 20 m. More information is needed on the siding...

  3. Lead phytotoxicity in soils and nutrient solutions is related to lead induced phosphorus deficiency

    International Nuclear Information System (INIS)

    Cheyns, Karlien; Peeters, Sofie; Delcourt, Dorien; Smolders, Erik

    2012-01-01

    This study was set up to relate lead (Pb) bioavailability with its toxicity to plants in soils. Tomato and barley seedlings were grown in six different PbCl 2 spiked soils (pH: 4.7–7.4; eCEC: 4.2–41.7 cmol c /kg). Soils were leached and pH corrected after spiking to exclude confounding factors. Plant growth was halved at 1600–6500 mg Pb/kg soil for tomato and at 1900–8300 mg Pb/kg soil for barley. These soil Pb threshold were unrelated to soil pH, organic carbon, texture or eCEC and neither soil solution Pb nor Pb 2+ ion activity adequately explained Pb toxicity among soils. Shoot phosphorus (P) concentrations significantly decreased with increasing soil Pb concentrations. Tomato grown in hydroponics at either varying P supply or at increasing Pb (equal initial P) illustrated that shoot P explained growth response in both scenarios. The results suggest that Pb toxicity is partially related to Pb induced P deficiency, likely due to lead phosphate precipitation. - Highlights: ► Tomato and barley shoot growth was affected by Pb toxicity in six different soils. ► Soil properties did not explain differences in plant Pb toxicity among soils. ► Neither soil solution Pb nor Pb 2+ ion activity explained Pb toxicity among soils. ► Shoot phosphorus concentration decreased with increasing soil Pb concentrations. ► Lead induced a P deficiency in plants, likely due to lead phosphate precipitation. - Soil properties did not explain differences in plant lead toxicity among different soils. Shoot phosphorus concentration decreased with increasing soil lead concentrations.

  4. The influence of declining air lead levels on blood lead-air lead slope factors in children.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Meng, Qingyu; Davis, Allen; Cohen, Jonathan; Lu, Shou-En; Svendsgaard, David; Brown, James S; Tuttle, Lauren; Hubbard, Heidi; Rice, Joann; Kirrane, Ellen; Vinikoor-Imler, Lisa C; Kotchmar, Dennis; Hines, Erin P; Ross, Mary

    2014-07-01

    It is difficult to discern the proportion of blood lead (PbB) attributable to ambient air lead (PbA), given the multitude of lead (Pb) sources and pathways of exposure. The PbB-PbA relationship has previously been evaluated across populations. This relationship was a central consideration in the 2008 review of the Pb national ambient air quality standards. The objectives of this study were to evaluate the relationship between PbB and PbA concentrations among children nationwide for recent years and to compare the relationship with those obtained from other studies in the literature. We merged participant-level data for PbB from the National Health and Nutrition Examination Survey (NHANES) III (1988-1994) and NHANES 9908 (1999-2008) with PbA data from the U.S. Environmental Protection Agency. We applied mixed-effects models, and we computed slope factor, d[PbB]/d[PbA] or the change in PbB per unit change in PbA, from the model results to assess the relationship between PbB and PbA. Comparing the NHANES regression results with those from the literature shows that slope factor increased with decreasing PbA among children 0-11 years of age. These findings suggest that a larger relative public health benefit may be derived among children from decreases in PbA at low PbA exposures. Simultaneous declines in Pb from other sources, changes in PbA sampling uncertainties over time largely related to changes in the size distribution of Pb-bearing particulate matter, and limitations regarding sampling size and exposure error may contribute to the variability in slope factor observed across peer-reviewed studies.

  5. Lead exposure from aluminum cookware in Cameroon

    International Nuclear Information System (INIS)

    Weidenhamer, Jeffrey D.; Kobunski, Peter A.; Kuepouo, Gilbert; Corbin, Rebecca W.; Gottesfeld, Perry

    2014-01-01

    Blood lead levels have decreased following the removal of lead from gasoline in most of the world. However, numerous recent studies provide evidence that elevated blood lead levels persist in many low and middle-income countries around the world at much higher prevalence than in the more developed countries. One potential source of lead exposure that has not been widely investigated is the leaching of lead from artisanal aluminum cookware, which is commonly used in the developing world. Twenty-nine samples of aluminum cookware and utensils manufactured by local artisans in Cameroon were collected and analyzed for their potential to release lead during cooking. Source materials for this cookware included scrap metal such as engine parts, radiators, cans, and construction materials. The lead content of this cookware is relatively low (< 1000 ppm by X-ray fluorescence), however significant amounts of lead, as well as aluminum and cadmium were released from many of the samples using dilute acetic acid extractions at boiling and ambient temperatures. Potential exposures to lead per serving were estimated to be as high as 260 μg, indicating that such cookware can pose a serious health hazard. We conclude that lead, aluminum and cadmium can migrate from this aluminum cookware during cooking and enter food at levels exceeding recommended public health guidelines. Our results support the need to regulate lead content of materials used to manufacture these pots. Artisanal aluminum cookware may be a major contributor to lead poisoning throughout the developing world. Testing of aluminum cookware in other developing countries is warranted. - Highlights: • Cookware is manufactured in Cameroon from scrap aluminum including car parts. • Twenty-nine cookware samples were evaluated for their potential to leach lead. • Boiling extractions to simulate the effects of cooking released significant lead. • Potential lead exposures per serving are estimated as high as 260 μg.

  6. Lead exposure from aluminum cookware in Cameroon

    Energy Technology Data Exchange (ETDEWEB)

    Weidenhamer, Jeffrey D.; Kobunski, Peter A. [Department of Chemistry, Geology and Physics, 401 College Ave., Ashland University, Ashland, OH 44805 (United States); Kuepouo, Gilbert [Research and Education Centre for Development (CREPD), Yaounde (Cameroon); Corbin, Rebecca W. [Department of Chemistry, Geology and Physics, 401 College Ave., Ashland University, Ashland, OH 44805 (United States); Gottesfeld, Perry, E-mail: pgottesfeld@okinternational.org [Occupational Knowledge International, San Francisco, CA (United States)

    2014-10-15

    Blood lead levels have decreased following the removal of lead from gasoline in most of the world. However, numerous recent studies provide evidence that elevated blood lead levels persist in many low and middle-income countries around the world at much higher prevalence than in the more developed countries. One potential source of lead exposure that has not been widely investigated is the leaching of lead from artisanal aluminum cookware, which is commonly used in the developing world. Twenty-nine samples of aluminum cookware and utensils manufactured by local artisans in Cameroon were collected and analyzed for their potential to release lead during cooking. Source materials for this cookware included scrap metal such as engine parts, radiators, cans, and construction materials. The lead content of this cookware is relatively low (< 1000 ppm by X-ray fluorescence), however significant amounts of lead, as well as aluminum and cadmium were released from many of the samples using dilute acetic acid extractions at boiling and ambient temperatures. Potential exposures to lead per serving were estimated to be as high as 260 μg, indicating that such cookware can pose a serious health hazard. We conclude that lead, aluminum and cadmium can migrate from this aluminum cookware during cooking and enter food at levels exceeding recommended public health guidelines. Our results support the need to regulate lead content of materials used to manufacture these pots. Artisanal aluminum cookware may be a major contributor to lead poisoning throughout the developing world. Testing of aluminum cookware in other developing countries is warranted. - Highlights: • Cookware is manufactured in Cameroon from scrap aluminum including car parts. • Twenty-nine cookware samples were evaluated for their potential to leach lead. • Boiling extractions to simulate the effects of cooking released significant lead. • Potential lead exposures per serving are estimated as high as 260 μg.

  7. Lead isotope analyses of standard rock samples

    International Nuclear Information System (INIS)

    Koide, Yoshiyuki; Nakamura, Eizo

    1990-01-01

    New results on lead isotope compositions of standard rock samples and their analytical procedures are reported. Bromide form anion exchange chromatography technique was adopted for the chemical separation lead from rock samples. The lead contamination during whole analytical procedure was low enough to determine lead isotope composition of common natural rocks. Silica-gel activator method was applied for emission of lead ions in the mass spectrometer. Using the data reduction of 'unfractionated ratios', we obtained good reproducibility, precision and accuracy on lead isotope compositions of NBS SRM. Here we present new reliable lead isotope compositions of GSJ standard rock samples and USGS standard rock, BCR-1. (author)

  8. Health impact from lead: IQ decrement

    Energy Technology Data Exchange (ETDEWEB)

    Easterly, C

    1994-07-01

    The effects of lead, once it is in the body, are the same no matter how it enters. Exposure to lead is especially dangerous for unborn children, with high levels associated with premature birth and low birth weight. Young children are at risk because they swallow lead when they put toys or other objects soiled with lead-containing dirt in their mouths. A greater proportion of the lead ingested by children enters their bodies than enters the bodies of adults. For infants and young children, lead exposure has been shown in some studies to decrease intelligence (IQ) scores, slow growth, and cause hearing problems. These effects can last as children get older and can be permanent. Realistic risk assessment for lead-induced neurobehavioral deficit in environmentally exposed children must stem from consistent results from independent studies, as well as the documentation of dose-response relationships. At present, studies investigating such effects have not been definitive. However, taken as a whole, there is growing support for the absence of a threshold for adverse effects in exposed children. Summary of selected recent studies and the obtained data are analyzed.

  9. Health impact from lead: IQ decrement

    International Nuclear Information System (INIS)

    Easterly, C.

    1994-01-01

    The effects of lead, once it is in the body, are the same no matter how it enters. Exposure to lead is especially dangerous for unborn children, with high levels associated with premature birth and low birth weight. Young children are at risk because they swallow lead when they put toys or other objects soiled with lead-containing dirt in their mouths. A greater proportion of the lead ingested by children enters their bodies than enters the bodies of adults. For infants and young children, lead exposure has been shown in some studies to decrease intelligence (IQ) scores, slow growth, and cause hearing problems. These effects can last as children get older and can be permanent. Realistic risk assessment for lead-induced neurobehavioral deficit in environmentally exposed children must stem from consistent results from independent studies, as well as the documentation of dose-response relationships. At present, studies investigating such effects have not been definitive. However, taken as a whole, there is growing support for the absence of a threshold for adverse effects in exposed children. Summary of selected recent studies and the obtained data are analyzed

  10. Lead and Drinking Water from Private Wells

    Science.gov (United States)

    ... type=”submit” value=”Submit” /> Healthy Water Home Lead and Drinking Water from Private Wells Recommend on ... remove lead from my drinking water? What is lead? Lead is a naturally occurring bluish-gray metal ...

  11. Superconducting lead particles produced by chemical techniques

    Science.gov (United States)

    Fariss, T. L.; Nixon, W. E.; Bucelot, T. J.; Deaver, B. S., Jr.; Mitchell, J. W.

    1982-09-01

    The superconductivity of extremely small lead particles has been studied as a function of size, surface condition, and connectivity using chemical techniques to produce particles of well-controlled size and shape suspended in insulating media. Approximately monodisperse suspensions of equiaxed, rod, and lath-shaped particles of lead halides and other lead compounds suspended in gelatin, polyacrylamide, polyvinylpyrrolidone, polyvinyl alcohol, methyl cellulose, and hydroxyethyl cellulose have been produced. These particles have been reduced to pseudomorphs of lead in the liquid phase or the suspensions have been coated on substrates and dried before reduction. Reducing solutions containing aminoiminomethanesulfinic acid are effective with particles of lead halides, lead phosphate, lead sulfate, and lead tartrate. Suspensions of smaller discrete lead particles have also been produced by direct reduction of solutions of soluble lead salts containing suitable polymers, chelating, and stabilizing agents. Dispersions with mean particle dimensions between 3 nm and 5 μm, and a narrow size-frequency distribution, have been produced. The superconductivity of the particles has been characterized by measurements of the magnetization as a function of temperature and magnetic field. The larger particles have a transition temperature of 7.2 K, the same as bulk lead; however, for particles of characteristic dimensions less than 20 nm, the transition temperature is lower by ˜0.1 K.

  12. Superconducting lead particles produced by chemical techniques

    International Nuclear Information System (INIS)

    Fariss, T.L.; Nixon, W.E.; Bucelot, T.J.; Deaver, B.S. Jr.; Mitchell, J.W.

    1982-01-01

    The superconductivity of extremely small lead particles has been studied as a function of size, surface condition, and connectivity using chemical techniques to produce particles of well-controlled size and shape suspended in insulating media. Approximately monodisperse suspensions of equiaxed, rod, and lath-shaped particles of lead halides and other lead compounds suspended in gelatin, polyacrylamide, polyvinylpyrrolidone, polyvinyl alcohol, methyl cellulose, and hydroxyethyl cellulose have been produced. These particles have been reduced to pseudomorphs of lead in the liquid phase or the suspensions have been coated on substrates and dried before reduction. Reducing solutions containing aminoiminomethanesulfinic acid are effective with particles of lead halides, lead phosphate, lead sulfate, and lead tartrate. Suspensions of smaller discrete lead particles have also been produced by direct reduction of solutions of soluble lead salts containing suitable polymers, chelating, and stabilizing agents. Dispersions with mean particle dimensions between 3 nm and 5 μm, and a narrow size-frequency distribution, have been produced. The superconductivity of the particles has been characterized by measurements of the magnetization as a function of temperature and magnetic field. The larger particles have a transition temperature of 7.2 K, the same as bulk lead; however, for particles of characteristic dimensions less than 20 nm, the transition temperature is lower by approx.0.1 K

  13. Current lead thermal analysis code 'CURRENT'

    International Nuclear Information System (INIS)

    Yamaguchi, Masahito; Tada, Eisuke; Shimamoto, Susumu; Hata, Kenichiro.

    1985-08-01

    Large gas-cooled current lead with the capacity more than 30 kA and 22 kV is required for superconducting toroidal and poloidal coils for fusion application. The current lead is used to carry electrical current from the power supply system at room temperature to the superconducting coil at 4 K. Accordingly, the thermal performance of the current lead is significantly important to determine the heat load requirements of the coil system at 4 K. Japan Atomic Energy Research Institute (JAERI) has being developed the large gas-cooled current leads with the optimum condition in which the heat load is around 1 W per 1 kA at 4 K. In order to design the current lead with the optimum thermal performances, JAERI developed thermal analysis code named as ''CURRENT'' which can theoretically calculate the optimum geometric shape and cooling conditions of the current lead. The basic equations and the instruction manual of the analysis code are described in this report. (author)

  14. 76 FR 11813 - Magnesium From China and Russia

    Science.gov (United States)

    2011-03-03

    ... and Russia Determinations On the basis of the record \\1\\ developed in the subject five-year reviews... in the United States within a reasonably foreseeable time. The Commission also determines,\\2... antidumping duty order on magnesium from Russia would not be likely to lead to continuation or recurrence of...

  15. Enhanced Cherenkov phase matching terahertz wave generation via a magnesium oxide doped lithium niobate ridged waveguide crystal

    Directory of Open Access Journals (Sweden)

    K. Takeya

    2017-01-01

    Full Text Available When combined with a nonlinear waveguide crystal, Cherenkov phase matching allows for highly effective generation of high power and broadband terahertz (THz waves. Using a ridged Lithium Niobate (LiNbO3 waveguide coupled with a specially designed silicon lens, we successfully generated THz waves with intensity of approximately three orders of magnitude stronger than those from conventional photoconductive antenna. The broadband spectrum was from 0.1 THz to 7 THz with a maximum dynamic range of 80 dB. The temporal shape of time domain pulse is a regular single cycle which could be used for high depth resolution time of flight tomography. The generated THz wave can also be easily monitored by compact room-temperature THz camera, enabling us to determine the spatial characteristics of the THz propagation.

  16. A comparison of the diminution rates of lead in blood and lead mobilized by CaEDTA after termination of occupational exposure: a long-term observation in two lead workers.

    Science.gov (United States)

    Araki, S; Murata, K; Aono, H; Yanagihara, S; Ushio, K

    1983-07-01

    CaEDTA 20 mg/kg was administered weekly for 3.5 years after termination of occupational exposure to two lead workers. The diminution half-lives for lead in blood and urine lead mobilized by CaEDTA were 4.8 and 3.3 years respectively for subject 1 following 28 years exposure and 3.3 and 2.0 years respectively for subject 2 following 26 years exposure. The difference in the diminution rate between lead in blood and lead mobilized by CaEDTA was significant in subject 2 (p less than 0.05).

  17. The effect of the hemochromatosis (HFE genotype on lead load and iron metabolism among lead smelter workers.

    Directory of Open Access Journals (Sweden)

    Guangqin Fan

    Full Text Available Both an excess of toxic lead (Pb and an essential iron disorder have been implicated in many diseases and public health problems. Iron metabolism genes, such as the hemochromatosis (HFE gene, have been reported to be modifiers for lead absorption and storage. However, the HFE gene studies among the Asian population with occupationally high lead exposure are lacking.To explore the modifying effects of the HFE genotype (wild-type, H63D variant and C282Y variant on the Pb load and iron metabolism among Asian Pb-workers with high occupational exposure.Seven hundred and seventy-one employees from a lead smelter manufacturing company were tested to determine their Pb intoxication parameters, iron metabolic indexes and identify the HFE genotype. Descriptive and multivariate analyses were conducted.Forty-five H63D variant carriers and no C282Y variant carrier were found among the 771 subjects. Compared with subjects with the wild-type genotype, H63D variant carriers had higher blood lead levels, even after controlling for factors such as age, sex, marriage, education, smoking and lead exposure levels. Multivariate analyses also showed that the H63D genotype modifies the associations between the blood lead levels and the body iron burden/transferrin.No C282Y variant was found in this Asian population. The H63D genotype modified the association between the lead and iron metabolism such that increased blood lead is associated with a higher body iron content or a lower transferrin in the H63D variant. It is indicated that H63D variant carriers may be a potentially highly vulnerable sub-population if they are exposed to high lead levels occupationally.

  18. Measurements of vector boson production in lead–lead and proton–lead collisions with the ATLAS detector

    International Nuclear Information System (INIS)

    Grabowska-Bold, Iwona

    2014-01-01

    Photons and weak bosons do not interact strongly and, thus, their production yields provide direct tests of scaling with a number of binary nucleon–nucleon collisions in the heavy-ion environment. In addition, they should be sensitive to the nuclear modification of parton distribution functions (nPDF). Proton-lead collisions also provide an excellent opportunity to test nPDF in a less dense environment than lead–lead via looking at forward–backward production of weak bosons. The ATLAS detector has proven to be an excellent apparatus in measurements involving photons, electrons and muons, the latter being products of weak boson decays, in the high occupancy environment produced in heavy-ion collisions. The experiment has recorded 30nb −1 of proton–lead data and 140μb −1 of lead–lead data, both of which have similar integrated partonic luminosities. We present the prompt photon, Z and W boson yields as a function of centrality, and also differentially in transverse momentum and rapidity, in lead–lead and proton–lead collisions from the ATLAS experiment. For W ± bosons, a lepton charge asymmetry has also been studied, which may also shed light on nPDF

  19. Environmental lead pollution and elevated blood lead levels among children in a rural area of China.

    Science.gov (United States)

    Lin, Sihao; Wang, Xiaorong; Yu, Ignatius Tak Sun; Tang, Wenjuan; Miao, Jianying; Li, Jin; Wu, Siying; Lin, Xing

    2011-05-01

    We investigated environmental lead pollution and its impact on children's blood lead levels (BLLs) in a rural area of China. In 2007, we studied 379 children younger than 15 years living in 7 villages near lead mines and processing plants, along with a control group of 61 children from another village. We determined their BLLs and collected environmental samples, personal data, and information on other potential exposures. We followed approximately 86% of the children who had high BLLs (> 15 μg/dL) for 1 year. We determined factors influencing BLLs by multivariate linear regression. Lead concentrations in soil and household dust were much higher in polluted villages than in the control village, and more children in the polluted area than in the control village had elevated BLLs (87%, 16.4 μg/dL vs 20%, 7.1 μg/dL). Increased BLL was independently associated with environmental lead levels. We found a significant reduction of 5 micrograms per deciliter when we retested children after 1 year. Our data show that the lead industry caused serious environmental pollution that led to high BLLs in children living nearby.

  20. Early Reading Proficiency. Leading Indicator Spotlight

    Science.gov (United States)

    Musen, Lindsey

    2010-01-01

    In "Beyond Test Scores: Leading Indicators for Education," Foley and colleagues (2008) define leading indicators as those that "provide early signals of progress toward academic achievement" (p. 1) and stress that educators "need leading indicators to help them see the direction their efforts are going in and to take…

  1. Association of Lead Levels and Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Neha Bansal MD

    2017-03-01

    Full Text Available Background: Cerebral palsy is a common motor disability in childhood. Raised lead levels affect cognition. Children with cerebral palsy may have raised lead levels, further impairing their residual cognitive motor and behavioral abilities. Environmental exposure and abnormal eating habits may lead to increased lead levels. Aims and Objectives: To measure blood lead levels in children with cerebral palsy and compare them with healthy neurologically normal children. To correlate blood lead levels with environmental factors. Material and Methods: Design: Prospective case-control study. Setting: Tertiary care hospital. Participants: Cases comprised 34 children with cerebral palsy, and controls comprised 34 neurologically normal, age- and sex-matched children. Methods: Clinical and demographic details were recorded as per proforma. Detailed environmental history was recorded to know the source of exposure to lead. These children were investigated and treated as per protocol. Venous blood was collected in ethylenediaminetetraacetic acid vials for analysis of blood lead levels. Lead levels were estimated by Schimadzu Flame AA-6800 (atomic absorption spectrophotometer. Data were analyzed using SPSS version 17. P < .05 was taken as significant. Results: Mean blood lead levels were 9.20 ± 8.31 µg/dL in cerebral palsy cases and 2.89 ± 3.04 µg/dL in their controls (P < .001. Among children with cerebral palsy, 19 (55.88% children had blood lead levels ≥5 µg/dL. Lead levels in children with pica were 12.33 ± 10.02 µg/dL in comparison to children with no history of pica, 6.70 ± 4.60 µg/dL (P = .029. No correlation was found between hemoglobin and blood lead levels in cases and controls. Conclusion: In our study, blood lead levels are raised in children with cerebral palsy. However, further studies are required to show effects of raised levels in these children.

  2. The impact of using lead pellets on lead contamination of mallards (Anas platyrhynchos in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Zdeňka Hutařová

    2013-01-01

    Full Text Available The aim of the study was to assess the degree of lead contamination in mallards in the Czech Republic as a result of using lead shots for wildfowling. Two sites used for mallard hunting were chosen, namely a flood-control reservoir in Moravia and a small fishpond in Bohemia. Lead concentrations were determined in the tissues of 20 mallards (Anas platyrhynchos raised at those standing open water sites (n = 10 at each site and killed there during the autumn hunting season with a steel shot. Control groups were made up of 20 mallards from the same breeding facility as experimental groups but raised in an enclosure without access to water (n = 10 at each site. Lead concentrations were determined in selected tissues (breast muscle, heart, liver, gizzard, kidney, feathers - quill base, lung, brain and humerus by high resolution continuum source atomic absorption spectrometry. The results showed elevated lead concentrations in all tissues of mallards compared with control in the reservoir in Southern Moravia. The highest lead concentrations (mg/kg were found in the humerus (14.254 ± 4.525 and 5.083 ± 0.748 for experimental and control mallards, respectively. In contrast, lead concentrations in mallards from small fishpond in Southern Bohemia were lower compared to control. Similarly, the highest lead concentrations were found in the humerus (2.219 ± 0.349 and 8.930 ± 1.012 for experimental and control mallards, respectively. This study extends very limited information about lead contamination of wild ducks in the Czech Republic in connection with hunting activities.

  3. Effect of pH, temperature, and lead concentration on the bioremoval of lead from water using Lemna minor.

    Science.gov (United States)

    Uysal, Yağmur; Taner, Fadime

    2009-09-01

    This study examined the ability of the aquatic plant Lemna minor (duckweed) to remove soluble lead under various laboratory conditions. In a batch process L. minor was exposed to different pH values (4.5-8.0) and temperature (15-35 degrees C) in presence of different lead concentrations (0.1-10.0 mg L(-1)) for 168 h. The amount of biomass obtained in the study period on a dry weight basis, the concentrations of lead in tissue and in medium and net uptake of lead by Lemna all have been determined in each condition. The percentages of lead uptake ratios (PMU) and bioconcentration factors (BCF) were also calculated for these conditions. Bioaccumulated lead concentrations and the PMU were obtained at lowest pH of 4.5, and at 30 degrees C. The highest accumulated lead concentration was found at pH 4.5 as 3.599 mg Pb g(-1) in 10.0 mg L(-1). It decreased to pH 6.0, but it did not change at pH 6.0-8.0 range. The maximum lead accumulation was obtained at 30 degrees C as 8.622 mg Pb g(-1) in 10 mg L(-1) at pH 5.0, and the minimum was at 15 degrees C as 0.291 mg g(-1) in 0.1 mg L(-1). Lead accumulation gradually increased with increasing lead in medium, but the opposite trend was observed for PMU. Lead accumulation increased up to 50 mg L(-1), but did not change significantly in the 50.0-100.0 mg L(-1) range. The lead uptake from water was modeled and the equation fit the experimental data very well

  4. Air pollution from lead added to gasoline

    Energy Technology Data Exchange (ETDEWEB)

    Dingeon, B; Collombel, C

    1973-01-01

    General hygienic and toxicological problems of lead added to gasoline are discussed. Lead emitted by motor vehicles pollutes the air especially in cities and along highways, and is accumulated by soil and plants. The lead levels found in the blood of subjects living in cities and near highways was significantly higher than in rural dwellers. Close correlation between the atmospheric lead concentration and the carbon monoxide concentration as well as the traffic density was established, indicating traffic as the source of atmospheric lead. The effect of traffic on the atmospheric lead concentration extended over a distance of up to 4 km. The lead, emitted by motor vehicles in the form of submicron particles, is retained in the organism at rates of 5-10 percent following ingestion, and at rates of 30-50 percent when inhaled. Lead is partially excreted by the liver, kidney, hair, and nails. Some 95 percent of the retained lead is found in the blood, and accumulation in the bones with potential mobilization due to increases in the corticosteroid level was observed. Exposure to lead can be diagnosed by basophil granulation test, urine delta-aminolevulinic acid test, and delta-aminolevulinic acid dehydratase test.

  5. Lead arthritis and lead poisoning following bullet wounds: a clinicopathologic, ultrastructural, and microanalytic study of two cases.

    Science.gov (United States)

    Slavin, R E; Swedo, J; Cartwright, J; Viegas, S; Custer, E M

    1988-02-01

    Bullet wounds causing lead synovitis in the wrist and knee are reported in two patients, one of whom also developed clinical plumbism. Very high lead levels in the synovial fluid are believed to be responsible for toxicity changes that occurred in the synovium and bone. Ultrastructurally, these alterations included the formation of nuclear lead inclusions, dilation, and degranulation of the rough endoplasmic reticulum and deposition of crystalline precipitates in the matrix of the mitochondria in macrophages, osteoclasts, and synoviocytes, as well as the development of cytoplasmic lead inclusions in osteoclasts. Energy-dispersive x-ray elemental analysis (EDXEA) indicated that the nuclear inclusions contained only lead, whereas precipitates within the mitochondria and elsewhere in the cytoplasm were composed of complexes containing lead, calcium, and phosphorus. Similarly constituted extracellular complexes were incorporated into newly formed trabecular bone laid down as a physiologic response to the bullet lodged within the wrist bones. This bone subsequently exhibited defects in bone resorption, which were characterized by depressed osteoclastic function and a unique lesion termed incomplete osteocytic osteolysis. The genesis of this latter lesion is uncertain. The sequestration of the partially degraded bone fragments containing lead complexes into the marrow and eventually into the joint spaces and synovium permitted the recycling of bone lead, and this may have played an important role in inducing clinical plumbism in one of the patients in this study.

  6. Experimental lead intoxication in dogs: a comparison of blood lead and urinary delta-aminolevulinic acid following intoxication and chelation therapy.

    Science.gov (United States)

    Green, R A; Selby, L A; Zumwalt, R W

    1978-01-01

    Intravenous lead administration to dogs produced an acute syndrome of lead intoxication charcterized by depression, vomiting, anorexia and weight loss. The effect of chelation therapy with calcium disodium ethylene diamine tetraacetate, penicillamine or both was determined by serially monitoring changes in blood lead and urine delta-aminolevulinic acid. Following therapy, blood lead values were significantly lower in chelated dogs than non-treated lead exposed dogs on days 7 and 10. Urine delta-aminolevulinic acid at day 7 was significantly higher in untreated lead exposed dogs than in other groups. There was no significant difference in blood lead or urine delta-aminolevulinic acid between lead intoxicated dogs which underwent the indicated chelation therapy protocols. There was, however, a trend for higher urinary delta-aminolevulinic acid excretion in those intoxicated dogs undergoing calcium disodium ethylene diamine tetraacetate therapy as opposed to those undergoing penicilamine therapy. There was no significant correlation between blood lead and urinary delta-aminolevulinic acid previous to lead exposure. However, after lead exposure significant correlation was present at days 4, 7, 10 and 14. Certain lead exposed dogs following chelation therapy were noted to have normal blood lead levels but elevated urinary delta-aminolevulinic acid suggesting that blood lead does not always correlate with metabolic effects of lead in the body. Urinary delta-aminolevulinic acid was therefore recommended as an additional laboratory parameter which improved assessment of lead exposure in dogs, particularly in determining adequacy of chelation therapy. PMID:667707

  7. Leading gravitational corrections and a unified universe

    DEFF Research Database (Denmark)

    Codello, Alessandro; Jain, Rajeev Kumar

    2016-01-01

    Leading order gravitational corrections to the Einstein-Hilbert action can lead to a consistent picture of the universe by unifying the epochs of inflation and dark energy in a single framework. While the leading local correction induces an inflationary phase in the early universe, the leading...... nonlocal term leads to an accelerated expansion of the universe at the present epoch. We argue that both the leading UV and IR terms can be obtained within the framework of a covariant effective field theory of gravity. The perturbative gravitational corrections therefore provide a fundamental basis...

  8. Integrating amplifiers for PHENIX lead-glass and lead-scintillator calorimeters

    International Nuclear Information System (INIS)

    Wintenberg, A.L.; Simpson, M.L.; Britton, C.L. Jr.; Palmer, R.L.; Jackson, R.G.

    1995-01-01

    Two types of integrating amplifier systems have been developed for use with lead-glass and lead-scintillator calorimeters with photomultiplier tube readout. Requirements for the amplifier system include termination of the line from the photomultiplier, compact size and low power dissipation to allow multiple channels per chip, dual range outputs producing 10-bit accuracy over a 14-bit dynamic range, rms noise levels of one LSB or less, and compatibility with timing filter amplifiers, tower sum circuits for triggering and calibration circuits to be built on the same integrated circuit (IC). Advantages and disadvantages of an active integrator system are compared and contrasted to those of a passive integrator-based system. In addition, details of the designs and results from prototype devices including an 8-channel active integrator IC fabricated in 1.2 microm Orbit CMOS are presented

  9. 40 CFR 1508.16 - Lead agency.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Lead agency. 1508.16 Section 1508.16 Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY TERMINOLOGY AND INDEX § 1508.16 Lead agency. Lead agency means the agency or agencies preparing or having taken primary responsibility for preparing the...

  10. Neutronic design for a 100MWth Small modular natural circulation lead or lead-alloy cooled fast reactors core

    International Nuclear Information System (INIS)

    Chen, C.; Chen, H.; Zhang, H.; Chen, Z.; Zeng, Q.

    2015-01-01

    Lead or lead-alloy cooled fast reactor with good fuel proliferation and nuclear waste transmutation capability, as well as high security and economy, is a great potential for the development of fourth-generation nuclear energy systems. Small natural circulation reactor is an important technical route lead cooled fast reactors industrial applications, which has been chosen as one of the three reference technical for solution lead or lead-alloy cooled fast reactors by GIF lead-cooled fast reactor steering committee. The School of Nuclear Science and Technology of USTC proposed a small 100MW th natural circulation lead cooled fast reactor concept called SNCLFR-100 based realistic technology. This article describes the SNCLFR-100 reactor of the overall technical program, core physics calculation and analysis. The results show that: SNCLFR-100 with good neutronic and safety performance and relevant design parameters meet the security requirements with feasibility. (author)

  11. Lead poisoning in mink

    Energy Technology Data Exchange (ETDEWEB)

    Purdy, J G

    1962-03-01

    This paper describes a case of lead poisoning in minks. The mink were housed in pens which had been painted with a bridge paint containing lead. They had chewed on the pen and ingested the paint. The animals that did not die were moved to new pens, and vitamin D and calcium gluconate were added to their diets. In three days, a marked improvement was seen in the food and water consumption, and convolutions became less frequent.

  12. Blood Test: Lead (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Lead KidsHealth / For Parents / Blood Test: Lead What's ... español Análisis de sangre: plomo What Is a Blood Test? A blood test is when a sample of ...

  13. Load Dependent Lead Times and Sustainability

    DEFF Research Database (Denmark)

    Pahl, Julia; Voss, Stefan

    2016-01-01

    to prevent decreased quality or waste of production parts and products. This gains importance because waiting times imply longer lead times charging the production system with work in process inventories. Longer lead times can lead to quality losses due to depreciation, so that parts need to be reworked...... if possible or discarded. But return flows of products for rework or remanufacturing actions significantly complicate the production planning process. We analyze sustainability options with respect to lead time management by formulating a comprehensive mathematical model. We consider a deterministic, mixed...

  14. Isotope ratios of lead as pollutant source indicators

    International Nuclear Information System (INIS)

    Chow, T.J.; Snyder, C.B.; Earal, J.L.

    1975-01-01

    Each lead ore deposit has its characteristic isotope ratios which are fixed during mineral ore genesis, and this unique property can be used to indicate the source of lead pollutants in the environment. The wolld production of primary lead is tabulated, and the geochemical significances of lead isotope ratios are discussed. The manufacture of lead alkyl additives for gasoline, which is the major source of lead pollutants, utilizes about 10% of the world annual consumption of lead. The isotope ratios of lead in gasoline, aerosols, soils and plants are correlated. Lead additives in various brands of gasoline sold in one region do not have the same isotope ratios. Regional variations in isotope ratios of lead additives were observed. This reflects the fact that petroleum refineries obtained the additives from various lead alkyl manufacturers which utilized lead from different mining districts. A definite changing trend of isotope ratios of lead pollutants in the San Diego, California (USA), area was detected. The lead shows a gradual increase in its radiogenic components during the past decade. This trend can be explained by the change of lead sources used by the additive manufacturers: Lead isotope ratios of the mid-1960's gasoline additives in the United States of America reflected those of less radiogenic leads imported from Canada, Australia, Peru and Mexico. Since then, the U.S. lead production has doubled-mainly from the Missouri district of highly radiogenic lead. Meanwhile, there has been a decrease in total lead imports. These combined effects result in changes in isotope ratios, from the less to more radiogenic, of the pooled lead. (aothor)

  15. XRD, lead equivalent and UV-VIS properties study of Ce and Pr lead silicate glasses

    International Nuclear Information System (INIS)

    Alias, Nor Hayati; Abdullah, Wan Shafie Wan; Isa, Norriza Mohd; Isa, Muhammad Jamal Md; Zali, Nurazila Mat; Abdullah, Nuhaslinda Ee; Muhammad, Azali

    2014-01-01

    In this work, Cerium (Ce) and Praseodymium (Pr) containing lead silicate glasses were produced with 2 different molar ratios low (0.2 wt%) and high (0.4wt%). These types of glasses can satisfy the characteristics required for radiation shielding glasses and minimize the lead composition in glass. The radiation shielding properties of the synthesized glasses is explained in the form of lead equivalent study. The XRD diffraction and UV-VIS analysis were performed to observe the structural changes of the synthesis glasses at 1.5 Gy gamma radiation exposures

  16. Verification of radiation exposure using lead shields

    International Nuclear Information System (INIS)

    Hayashida, Keiichi; Yamamoto, Kenyu; Azuma, Masami

    2016-01-01

    A long time use of radiation during IVR (intervention radiology) treatment leads up to an increased exposure on IVR operator. In order to prepare good environment for the operator to work without worry about exposure, the authors examined exposure reduction with the shields attached to the angiography instrument, i. e. lead curtain and lead glass. In this study, the lumber spine phantom was radiated using the instrument and the radiation leaked outside with and without shields was measured by the ionization chamber type survey meter. The meter was placed at the position which was considered to be that for IVR operator, and changed vertically 20-100 cm above X-ray focus by 10 cm interval. The radiation at the position of 80 cm above X-ray focus was maximum without shield and was hardly reduced with lead curtain. However, it was reduced with lead curtain plus lead glass. Similar reduction effects were observed at the position of 90-100 cm above X-ray focus. On the other hand, the radiation at the position of 70 cm above X-ray focus was not reduced with either shield, because that position corresponded to the gap between lead curtain and lead glass. The radiation at the position of 20-60 cm above X-ray focus was reduced with lead curtain, even if without lead glass. These results show that lead curtain and lead glass attached to the instrument can reduce the radiation exposure on IVR operator. Using these shields is considered to be one of good means for IVR operator to work safely. (author)

  17. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

    Science.gov (United States)

    Maessen, J G; Phelps, B; Dekker, A L A J; Dijkman, B

    2004-05-01

    To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

  18. 29 CFR 1915.1025 - Lead.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Lead. 1915.1025 Section 1915.1025 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... Lead. Note: The requirements applicable to shipyard employment under this section are identical to...

  19. Exposure to lead from intake of coffee

    DEFF Research Database (Denmark)

    Hansen, Max; Sloth, Jens Jørgen; Rasmussen, Rie Romme

    Food and beverages is one of the primary sources of intake of and exposure to lead, with beverages accounting for almost 50%. Previous studies from Denmark have estimated that the intake of lead from coffee is very high and may contribute to up to 20% of the total lead intake from food and bevera......Food and beverages is one of the primary sources of intake of and exposure to lead, with beverages accounting for almost 50%. Previous studies from Denmark have estimated that the intake of lead from coffee is very high and may contribute to up to 20% of the total lead intake from food...... and beverages. This estimate is, however, based on older, non-published data. In the current project extensive chemical analyses of coffee beans, drinking water and ready-to-drink coffee have been performed. The results hereof have been compared to calculations of the total intake of lead from food...... and beverages. The results show that the intake of lead from coffee is considerably lower than previously estimated and account for 4.2% and 3.3% of the total lead intake from food and beverages for Danish men and women, respectively. It can generally be concluded that the intake of lead from coffee is low...

  20. Impacts of aerosol lead to natural ecosystems

    International Nuclear Information System (INIS)

    Murozumi, Masayo; Nakamura, Seiji; Yoshida, Katsumi

    1982-01-01

    Impacts of aerosol lead have changed the concentration and isotopic ratios of the element circulating in remote ecosystems in the Hidaka and Tarumae mountains. Concentrations of lead in successive each 10 years ring veneer of Cercidiphyllum Japonica show that amount of the element residing on the bark and supwood layers has increased by a factor of 2 or more in comparison with that of the core part. The isotopic ratios of lead in the basement rocks and soils under the ecosystems converge to a certain narrow spot along the isochron Iine of the element, and distinguish their geochronogical characteristics from other leads of different sources. In these ecosystems, however, the lead isotopic ratios of materials exposed to the atmosphere are similar to those of foreign and anthropogenic aerosol lead but are evidently dissimilar to those of the rocks and soils. Furthermore, the lead isotopic ratios in yearly ring veneers of Ceridiphyllum Japonica and Ostrya Japonica show a certain differentiation towards the bark from the core, i.e., an approach to those of anthropogenic aerosol lead from those of the basement rocks and soils, as listed in Table 7. The lead burden per hectare in these remote ecosystems has increased to 4 g by the impact of 2 g of aerosol lead. (author)

  1. Effect of lead on heme synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Neuberger, A.

    1975-01-01

    Recently, a fair amount of work has been done on the effect of lead on porphobilinogen dehydratase, which has been used as a sensitive indicator of lead poisoning. How far this is in itself harmful depends on the Michaelis constants of both the aminolaevulinic synthetase and of the dehydratase, and in addition on the relative activities of the two enzymes in a cell and also on the tissue concentration of glycine. Information on some of these points is still fragmentary, and a reliable judgement is at the present not very easy. Another step in the heme synthesis, which is sensitive to low concentrations of lead, is the incorporation of iron into protoporphyrin. Inhibition of this step may be important in accounting to a large extent for the anaemia found in individuals with lead poisoning. Reduction in the tissue concentration of heme or of heme-like compounds may also explain, through the mechanism of de-repression, the excretion of increased amounts of aminolaevulinic acid in the urine observed in cases of lead poisoning. A third step in heme synthesis, which might be sensitive to lead, is the oxidative decarboxylation of coproporphyrin to protoporphyrin, and this may explain why the former derivative is excreted in the urine. Recent work of the Harvard Medical School has indicated that greatly reduced levels of ALA dehydratase may be found in most cases of severe liver damage due to alcoholism. In most of these cases the level of lead in the blood is within normal limits, and there is no history of exposure to toxic amounts of lead. We therefore have to assume that a reduction in the blood level of this enzyme is not necessarily an indication of lead poisoning.

  2. Lead isotope in mineral exploration

    International Nuclear Information System (INIS)

    Gulson, B.L.

    1986-01-01

    This book provides an up-to-date state-of-the-art review of lead isotopes in mineral exploration. Beginning with an historical review on suggested uses of lead isotopes in mineral exploration, the author then outlines the theoretical aspects of lead isotopes and illustrates that the method is based on well-known principles of radioactive decay, from which isotopic signatures for different styles of mineralization are derived. The varying isotopic signatures are then introduced. The major part of the book details over 40 case histories for base and precious metals, uranium and tin using sampling media such as sulfides, gossans, soils, weathered bedrock, vegetation and groundwaters. Advantages and disadvantages of each are discussed. Examples are given of the use of lead isotopes in testing conceptual models for exploration. The success rate and cost-effectiveness of the method are illustrated by actual exploration examples. Analytical advances which should lower the cost of the method and future uses are outlined. Many of the case histories use recently published or unpublished data, 27 tables of which are given in an appendix. Details of sampling, the methods for obtaining the isotope ratios, and a commercially-available integrated lead isotope service are also provided. (Auth.)

  3. Alloying in an Intercalation Host: Metal Titanium Niobates as Anodes for Rechargeable Alkali-Ion Batteries.

    Science.gov (United States)

    Das, Suman; Swain, Diptikanta; Araujo, Rafael B; Shi, Songxin; Ahuja, Rajeev; Row, Tayur N Guru; Bhattacharyya, Aninda J

    2018-02-02

    We discuss here a unique flexible non-carbonaceous layered host, namely, metal titanium niobates (M-Ti-niobate, M: Al 3+ , Pb 2+ , Sb 3+ , Ba 2+ , Mg 2+ ), which can synergistically store both lithium ions and sodium ions via a simultaneous intercalation and alloying mechanisms. M-Ti-niobate is formed by ion exchange of the K + ions, which are specifically located inside galleries between the layers formed by edge and corner sharing TiO 6 and NbO 6 octahedral units in the sol-gel synthesized potassium titanium niobate (KTiNbO 5 ). Drastic volume changes (approximately 300-400 %) typically associated with an alloying mechanism of storage are completely tackled chemically by the unique chemical composition and structure of the M-Ti-niobates. The free space between the adjustable Ti/Nb octahedral layers easily accommodates the volume changes. Due to the presence of an optimum amount of multivalent alloying metal ions (50-75 % of total K + ) in the M-Ti-niobate, an efficient alloying reaction takes place directly with ions and completely eliminates any form of mechanical degradation of the electroactive particles. The M-Ti-niobate can be cycled over a wide voltage range (as low as 0.01 V) and displays remarkably stable Li + and Na + ion cyclability (>2 Li + /Na + per formula unit) for widely varying current densities over few hundreds to thousands of successive cycles. The simultaneous intercalation and alloying storage mechanisms is also studied within the density functional theory (DFT) framework. DFT expectedly shows a very small variation in the volume of Al-titanium niobate following lithium alloying. Moreover, the theoretical investigations also conclusively support the occurrence of the alloying process of Li ions with the Al ions along with the intercalation process during discharge. The M-Ti-niobates studied here demonstrate a paradigm shift in chemical design of electrodes and will pave the way for the development of a multitude of improved electrodes

  4. Measurement of lead compound in stack gas

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Y; Hori, M; Tanikawa, N

    1979-01-01

    The concentration and particle-size distribution of lead compounds in the exhaust gas from various stationary sources are examined. The stationary sources concern lead production from battery scraps, lead smelting of cable mold, steel production from iron scraps, plastic combustion furnace, and a heavy oil boiler. A lead concentration of 0.2-100 mg/cu m in exhaust gas is detected. Furthermore, exhaust gas lead compounds are affected by the raw materials used.

  5. Misled about lead: an assessment of online public health education material from Australia's lead mining and smelting towns.

    Science.gov (United States)

    Sullivan, Marianne; Green, Donna

    2016-01-06

    This study assesses the accuracy and comprehensiveness of online public health education materials from the three Australian cities with active lead mines and or smelters: Broken Hill, Mount Isa and Port Pirie. Qualitative content analysis of online Australian material with comparison to international best practice where possible. All materials provided incomplete information about the health effects of lead and pathways of exposure compared to best practice materials. Inconsistent strategies to reduce exposure to lead were identified among the Australian cities, and some evidence-based best practices were not included. The materials normalised environmental lead and neglected to identify that there is no safe level of lead, or that primary prevention is the best strategy for protecting children's health. Health education materials need to clearly state health risks from lead across developmental stages and for sensitive populations, integrate a primary prevention perspective, and provide comprehensive evidence-based recommendations for reducing lead exposure in and around the home. Families who rely on information provided by these online public education materials are likely to be inadequately informed about the importance of protecting their children from exposure to lead and strategies for doing so.

  6. Handbook on Lead-bismuth Eutectic Alloy and Lead Properties, Materials Compatibility, Thermal-hydraulics and Technologies - 2015 Edition

    International Nuclear Information System (INIS)

    Fazio, Concetta; Sobolev, V.P.; Aerts, A.; Gavrilov, S.; Lambrinou, K.; Schuurmans, P.; Gessi, A.; Agostini, P.; Ciampichetti, A.; Martinelli, L.; Gosse, S.; Balbaud-Celerier, F.; Courouau, J.L.; Terlain, A.; Li, N.; Glasbrenner, H.; Neuhausen, J.; Heinitz, S.; Zanini, L.; Dai, Y.; Jolkkonen, M.; Kurata, Y.; Obara, T.; Thiolliere, N.; Martin-Munoz, F.J.; Heinzel, A.; Weisenburger, A.; Mueller, G.; Schumacher, G.; Jianu, A.; Pacio, J.; Marocco, L.; Stieglitz, R.; Wetzel, T.; Daubner, M.; Litfin, K.; Vogt, J.B.; Proriol-Serre, I.; Gorse, D.; Eckert, S.; Stefani, F.; Buchenau, D.; Wondrak, T.; Hwang, I.S.

    2015-01-01

    Heavy liquid metals such as lead or lead-bismuth have been proposed and investigated as coolants for fast reactors since the 1950's. More recently, there has been renewed interest worldwide in the use of these materials to support the development of systems for the transmutation of radioactive waste. Heavy liquid metals are also under evaluation as a reactor core coolant and accelerator-driven system neutron spallation source. Several national and international R and D programmes are ongoing for the development of liquid lead-alloy technology and the design of liquid lead-alloy-cooled reactor systems. In 2007, a first edition of the handbook was published to provide deeper insight into the properties and experimental results in relation to lead and lead-bismuth eutectic technology and to establish a common database. This handbook remains a reference in the field and is a valuable tool for designers and researchers with an interest in heavy liquid metals. The 2015 edition includes updated data resulting from various national and international R and D programmes and contains new experimental data to help understand some important phenomena such as liquid metal embrittlement and turbulent heat transfer in a fuel bundle. The handbook provides an overview of liquid lead and lead-bismuth eutectic properties, materials compatibility and testing issues, key aspects of thermal-hydraulics and existing facilities, as well as perspectives for future R and D. (authors)

  7. Biomarker responses of Peromyscus leucopus exposed to lead and cadmium in the Southeast Missouri Lead Mining District.

    Science.gov (United States)

    Beyer, W Nelson; Casteel, Stan W; Friedrichs, Kristen R; Gramlich, Eric; Houseright, Ruth A; Nichols, John R; Karouna-Renier, Natalie K; Kim, Dae Young; Rangen, Kathleen L; Rattner, Barnett A; Schultz, Sandra L

    2018-01-29

    Biomarker responses and histopathological lesions have been documented in laboratory mammals exposed to elevated concentrations of lead and cadmium. The exposure of white-footed mice (Peromyscus leucopus) to these metals and the potential associated toxic effects were examined at three contaminated sites in the Southeast Missouri Lead Mining District and at a reference site in MO, USA. Mice from the contaminated sites showed evidence of oxidative stress and reduced activity of red blood cell δ-aminolevulinic acid dehydratase (ALAD). Histological examinations of the liver and kidney, cytologic examination of blood smears, and biomarkers of lipid peroxidation and DNA damage failed to show indications of toxic effects from lead. The biomagnification factor of cadmium (hepatic concentration/soil concentration) at a site with a strongly acid soil was 44 times the average of the biomagnification factors at two sites with slightly alkaline soils. The elevated concentrations of cadmium in the mice did not cause observable toxicity, but were associated with about a 50% decrease in expected tissue lead concentrations and greater ALAD activity compared to the activity at the reference site. Lead was associated with a decrease in concentrations of hepatic glutathione and thiols, whereas cadmium was associated with an increase. In addition, to support risk assessment efforts, we developed linear regression models relating both tissue lead dosages (based on a previously published a laboratory study) and tissue lead concentrations in Peromyscus to soil lead concentrations.

  8. Biomarker responses of Peromyscus leucopus exposed to lead and cadmium in the Southeast Missouri Lead Mining District

    Science.gov (United States)

    Beyer, W. Nelson; Casteel, Stan W.; Friedrichs, Kristen R.; Gramlich, Eric; Houseright, Ruth A.; Nichols, John W.; Karouna-Renier, Natalie; Kim, Dae Young; Rangen, Kathleen; Rattner, Barnett A.; Schultz, Sandra

    2018-01-01

    Biomarker responses and histopathological lesions have been documented in laboratory mammals exposed to elevated concentrations of lead and cadmium. The exposure of white-footed mice (Peromyscus leucopus) to these metals and the potential associated toxic effects were examined at three contaminated sites in the Southeast Missouri Lead Mining District and at a reference site in MO, USA. Mice from the contaminated sites showed evidence of oxidative stress and reduced activity of red blood cell δ-aminolevulinic acid dehydratase (ALAD). Histological examinations of the liver and kidney, cytologic examination of blood smears, and biomarkers of lipid peroxidation and DNA damage failed to show indications of toxic effects from lead. The biomagnification factor of cadmium (hepatic concentration/soil concentration) at a site with a strongly acid soil was 44 times the average of the biomagnification factors at two sites with slightly alkaline soils. The elevated concentrations of cadmium in the mice did not cause observable toxicity, but were associated with about a 50% decrease in expected tissue lead concentrations and greater ALAD activity compared to the activity at the reference site. Lead was associated with a decrease in concentrations of hepatic glutathione and thiols, whereas cadmium was associated with an increase. In addition, to support risk assessment efforts, we developed linear regression models relating both tissue lead dosages (based on a previously published a laboratory study) and tissue lead concentrations in Peromyscus to soil lead concentrations.

  9. Lead in Construction

    National Research Council Canada - National Science Library

    1993-01-01

    Although Occupational Safety and Health Administration (OSHA) regulations for occupational lead exposure have been in effect since 1971 for the construction and general industries, the agency regulations for general industry in 1978...

  10. Lead isotopes and lead shot ingestion in the globally threatened marbled teal (Marmaronetta angustirostris) and white-headed duck (Oxyura leucocephala)

    International Nuclear Information System (INIS)

    Svanberg, Fredrik; Mateo, Rafael; Hillstroem, Lars; Green, Andy J.; Taggart, Mark A.; Raab, Andrea; Meharg, Andy A.

    2006-01-01

    Lead isotope ratios ( 206 Pb/ 207 Pb and 208 Pb/ 207 Pb) and concentrations in the livers and bones of marbled teal and white-headed duck found dead or moribund were determined in order to establish the main lead source in these waterfowl species. Lead concentrations in bone (dry weight) and liver (wet weight) were found to be very high in many of the white-headed ducks (bone: geometric mean = 88.9 ppm, maximum = 419 ppm; liver: geometric mean = 16.8 ppm, maximum = 57.0 ppm). Some of the marbled teal had high lead levels in the bones but liver lead levels were all low (bone: geometric mean = 6.13 ppm, maximum = 112 ppm; liver: geometric mean = 0.581 ppm, maximum = 4.77 ppm). Ingested lead shot were found in 71% of the white-headed duck and 20% of the marbled teal. The 206 Pb/ 207 Pb ratio in livers and bones of white-headed ducks and marbled teals showed no significant differences compared to the ratios obtained from lead shot. The 206 Pb/ 207 Pb ratio in bones of marbled teal ducklings with the highest lead concentrations tended to resemble the ratios of lead shot, which supports our hypothesis that the lead was derived from the hens. We also found that the lead ratios of lead shot and lead ratios described for soils in the area overlapped, but also that the isotopic ratio 206 Pb/ 207 Pb in lead shot used in Spain has a narrow range compared with those used in North America. The principal source of lead in many of these birds was, however, most likely lead shot, as supported by the similar isotopic ratios, high lead concentrations in tissues and evidence of ingested shot

  11. Lead isotopes and lead shot ingestion in the globally threatened marbled teal (Marmaronetta angustirostris) and white-headed duck (Oxyura leucocephala)

    Energy Technology Data Exchange (ETDEWEB)

    Svanberg, Fredrik [Department of Environmental Toxicology, Evolutionary Biology Centre, Uppsala University, Norbyvaegen 18A, SE-752 36 Uppsala (Sweden)]. E-mail: fredriksvanberg@hotmail.com; Mateo, Rafael [Instituto de Investigacion en Recursos Cinegeticos, IREC (CSIC-UCLM-JCCM), Ronda de Toledo s/n, 13071 Ciudad Real (Spain); Hillstroem, Lars [Institute of Maths, Natural and Computer Science, University of Gaevle, SE-801 76 Gaevle (Sweden); Green, Andy J. [Wetland Ecology Group, Estacion Biologica de Donana-CSIC, Pabellon del Peru, Avenida Maria Luisa s/n, E-40013 Seville (Spain); Taggart, Mark A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Raab, Andrea [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Meharg, Andy A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom)

    2006-11-01

    Lead isotope ratios ({sup 206}Pb/{sup 207}Pb and {sup 208}Pb/{sup 207}Pb) and concentrations in the livers and bones of marbled teal and white-headed duck found dead or moribund were determined in order to establish the main lead source in these waterfowl species. Lead concentrations in bone (dry weight) and liver (wet weight) were found to be very high in many of the white-headed ducks (bone: geometric mean = 88.9 ppm, maximum = 419 ppm; liver: geometric mean = 16.8 ppm, maximum = 57.0 ppm). Some of the marbled teal had high lead levels in the bones but liver lead levels were all low (bone: geometric mean = 6.13 ppm, maximum = 112 ppm; liver: geometric mean = 0.581 ppm, maximum = 4.77 ppm). Ingested lead shot were found in 71% of the white-headed duck and 20% of the marbled teal. The {sup 206}Pb/{sup 207}Pb ratio in livers and bones of white-headed ducks and marbled teals showed no significant differences compared to the ratios obtained from lead shot. The {sup 206}Pb/{sup 207}Pb ratio in bones of marbled teal ducklings with the highest lead concentrations tended to resemble the ratios of lead shot, which supports our hypothesis that the lead was derived from the hens. We also found that the lead ratios of lead shot and lead ratios described for soils in the area overlapped, but also that the isotopic ratio {sup 206}Pb/{sup 207}Pb in lead shot used in Spain has a narrow range compared with those used in North America. The principal source of lead in many of these birds was, however, most likely lead shot, as supported by the similar isotopic ratios, high lead concentrations in tissues and evidence of ingested shot.

  12. Lead--still a health threat for marksmen.

    Science.gov (United States)

    Ochsmann, Elke; Göen, Thomas; Schaller, Karl-Heinz; Drexler, Hans

    2009-09-01

    Indoor shooting is a popular recreational activity all over the world. It is also a known source of exposure to lead fumes and dusts for the general, i.e. the non-occupationally exposed population. This study aimed at reporting the lead levels in blood of indoor shooters in Germany in association with personal behaviour at shooting ranges. Seven marksmen were examined via self-administered questionnaires. Lead level in blood (BLL) as well as airborne lead concentration (personal air sampling (PAS)) were detected. All measured blood lead levels (median: 290 microglead/L; range: 240-450 microglead/L) exceeded the values of the German general population (50 microg/L). Shooters sweeping the range after training seemed especially exposed (PAS: 7.14 mglead/m3). While extensive public effort is undertaken to prevent the general population from environmental lead exposure this short report gives reason to keep recreational shooting in mind when facing elevated blood lead levels or clinical symptoms possibly associated with lead intoxication.

  13. Association of Lead Levels and Cerebral Palsy

    Science.gov (United States)

    Bansal, Neha; Aggarwal, Anju; Faridi, M. M. A.; Sharma, Tusha; Baneerjee, B. D.

    2017-01-01

    Background: Cerebral palsy is a common motor disability in childhood. Raised lead levels affect cognition. Children with cerebral palsy may have raised lead levels, further impairing their residual cognitive motor and behavioral abilities. Environmental exposure and abnormal eating habits may lead to increased lead levels. Aims and Objectives: To measure blood lead levels in children with cerebral palsy and compare them with healthy neurologically normal children. To correlate blood lead levels with environmental factors. Material and Methods: Design: Prospective case-control study. Setting: Tertiary care hospital. Participants: Cases comprised 34 children with cerebral palsy, and controls comprised 34 neurologically normal, age- and sex-matched children. Methods: Clinical and demographic details were recorded as per proforma. Detailed environmental history was recorded to know the source of exposure to lead. These children were investigated and treated as per protocol. Venous blood was collected in ethylenediaminetetraacetic acid vials for analysis of blood lead levels. Lead levels were estimated by Schimadzu Flame AA-6800 (atomic absorption spectrophotometer). Data were analyzed using SPSS version 17. P pica were 12.33 ± 10.02 µg/dL in comparison to children with no history of pica, 6.70 ± 4.60 µg/dL (P = .029). No correlation was found between hemoglobin and blood lead levels in cases and controls. Conclusion: In our study, blood lead levels are raised in children with cerebral palsy. However, further studies are required to show effects of raised levels in these children. PMID:28491920

  14. Lead poisoning from souvenir earthenware.

    Science.gov (United States)

    Hellström-Lindberg, Eva; Björklund, Andreas; Karlson-Stiber, Christine; Harper, Pauline; Seldén, Anders I

    2006-02-01

    A case of massive lead poisoning from juice contained in a Greek earthenware jug as well as six satellite cases of high lead exposure of similar origin is reported. The intoxicated patient was successfully treated with dimercaptosuccinic acid. Ceramic producers should adhere to the longstanding European legislation.

  15. [Effect of the chelator Zn-DTPA on the excretion of lead in lead intoxication mice detected with ICP-MS].

    Science.gov (United States)

    Li, Chen; Lu, Kai-zhi; Zhou, Qi; Wang, Qiong; Zeng, Yu-liang; Yin, Hong-jun; He, Xuan-hui; Tian, Ying; Dong, Jun-Xing

    2014-11-01

    To study the lead excretion effect of the chelator Zn-DTPA on the lead intoxication mice, inductively coupled plasma mass spectrometry (ICP-MS) was applied to detect the lead content of biological samples. The acute lead intoxication mice model was established by injecting lead acetate intraperitoneally with the dose of 1 mg. Zn-DTPA was administered intraperitoneally to mice once daily for five consecutive days 4 h after intoxication. Control group, model group, combination of Zn-DTPA and Ca-DTPA group were evaluated at the same time. The urine was collected every day. The mice were sacrificed in batches in the 2rd, 4th, 6th day. Biological samples including urine, whole blood, femur and brain were prepared and nitrated. Lead concentration was detected by ICP-MS. The result showed that Zn-DTPA could increase lead content in urine markedly and reduce lead content in blood, femur and brain.

  16. 40 CFR 52.1375 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead national...

  17. Childhood lead exposure in France: benefit estimation and partial cost-benefit analysis of lead hazard control

    Directory of Open Access Journals (Sweden)

    Zmirou-Navier Denis

    2011-05-01

    Full Text Available Abstract Background Lead exposure remains a public health concern due to its serious adverse effects, such as cognitive and behavioral impairment: children younger than six years of age being the most vulnerable population. In Europe, the lead-related economic impacts have not been examined in detail. We estimate the annual costs in France due to childhood exposure and, through a cost benefit analysis (CBA, aim to assess the expected social and economic benefits of exposure abatement. Methods Monetary benefits were assessed in terms of avoided national costs. We used results from a 2008 survey on blood-lead (B-Pb concentrations in French children aged one to six years old. Given the absence of a threshold concentration being established, we performed a sensitivity analysis assuming different hypothetical threshold values for toxicity above 15 μg/L, 24 μg/L and 100 μg/L. Adverse health outcomes of lead exposure were translated into social burden and economic costs based on literature data from literature. Direct health benefits, social benefits and intangible avoided costs were included. Costs of pollutant exposure control were partially estimated in regard to homes lead-based paint decontamination, investments aiming at reducing industrial lead emissions and removal of all lead drinking water pipes. Results The following overall annual benefits for the three hypothetical thresholds values in 2008 are: €22.72 billion, €10.72 billion and €0.44 billion, respectively. Costs from abatement ranged from €0.9 billion to 2.95 billion/year. Finally, from a partial CBA of lead control in soils and dust the estimates of total net benefits were € 3.78 billion, € 1.88 billion and €0.25 billion respectively for the three hypothesized B-Pb effect values. Conclusions Prevention of childhood lead exposure has a high social benefit, due to reduction of B-Pb concentrations to levels below 15 μg/L or 24 μg/L, respectively. Reducing only exposures

  18. Relationship Between Total and Biaccessible Lead on Children's Blood Lead Levles in Urban Residential Philadelphia Soils.

    Data.gov (United States)

    U.S. Environmental Protection Agency — Relationship Between Total and Biaccessible Lead on Children's Blood Lead Levles in Urban Residential Philadelphia Soils. This dataset is not publicly accessible...

  19. Removal of lead from crude antimony by using NaPo3 as lead elimination reagent

    Directory of Open Access Journals (Sweden)

    Ye L.G.

    2015-01-01

    Full Text Available In order to solve the shortcomings when removing lead from crude antimony in the traditional antimony smelting, a new process was provided using NaPO3 as lead elimination reagent to yield phosphate slag, and it was removed by floating on the surface of the liquid antimony. Reaction mechanism was clarified by using the TG-DTA and XRD techniques and single factor experiments of removal lead from crude antimony were engaged. The results show that PbO and NaPO3 begin endothermic reaction at 863K (590°C, and the reaction mainly form NaPb4(PO43 and NaPbPO4 below 1123K (850°C and above 1123K (850°C, respectively. Sb2O3 and NaPO3 start the reaction at 773K (500°C and generate an antimonic salt compound. The reaction product of the mixture of PbO, Sb2O3 and NaPO3 show that NaPO3 reacted with PbO prior when NaPO3 was insufficient, amorphous antimony glass will be generated only when NaPO3 was adequate. Single factor experiments were taken with NaNO3 as oxidizing agent under argon, effect of reaction time, reaction temperature and dosage of NaPO3 and NaNO3 on smelting results. The average content of lead in refined antimony was 0.05340% and 98.85% of lead were removed under optimal conditions; the content of lead in antimony have meet the requirements of commercial antimony.

  20. Chronic Lead Intoxication From Eating Wild-Harvested Game.

    Science.gov (United States)

    Buenz, Eric J; Parry, Gareth J

    2018-05-01

    The purpose of this article is to determine if conversion from eating wild game harvested with lead-based ammunition to nonlead-based ammunition results in lower blood lead levels. Supersonic injection of toxin-leeching frangible projectiles into food is intuitively bad. As much as 95% of the ~13.7 million hunters in the United States choose shrapnel-inducing lead bullets to kill game; in addition, not harvesting meat is an incarcerable crime. A lead ammunition ban on certain federal lands was recently rescinded and the National Rifle Association refutes any risk from eating lead bullet-harvested game. A patient subsisting solely on lead-shot meat was converted to non-lead ammunition and his blood lead level tracked. Concomitant with his conversion to nonlead ammunition, a controlled experiment was performed using the patient's bullets to determine his daily lead intake from lead-shot meat. While eating lead-shot meat, the patient was consuming 259.3 ± 235.6 µg of lead daily and his blood lead level was 74.7 µg/dL. Conversion to nonlead ammunition was associated with a reduced blood lead level. Unsafe blood lead levels can occur from eating game harvested with lead ammunition. Physicians should warn hunting patients of this potential risk and counsel them about the availability of nonlead ammunition alternatives. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. 21 CFR 870.3620 - Pacemaker lead adaptor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...

  2. Association of Lead Exposure, Serum Uric Acid and Parameters of Renal Function in Nigerian Lead-Exposed Workers

    Directory of Open Access Journals (Sweden)

    DD Alasia

    2010-09-01

    Full Text Available Background: The presence of hyperuricemia and renal function impairment, especially in the absence of urate stone formation is strongly suggestive of lead nephropathy. The evaluation of this association is essential in areas where lead exposure is still prevalent and uncontrolled. Objective: To determine the relationship between serum uric acid and renal function indices in lead-exposed workers. Methods: A cross-sectional study of 190 adults with occupational lead exposure and 80 adults (comparison group, matched for age and sex was performed in Port Harcourt, South-south Nigeria. Blood lead was used as the biomarker of lead exposure while serum urea, serum creatinine, urine albumin (using urine albumin:creatinine ratio, estimated glomerular filtration rate (GFR and serum uric acid were the renal function indices measured. Results: Occupationally lead-exposed subjects had a significantly (p = 0.008 higher mean±SD blood lead levels (50.37±24.58 μg/dL than the comparison group (41.40±26.85. The mean±SD serum urea (8.6±2.3 mg/dL, creatinine (1.0±0.2 mg/dL and serum uric acid (4.6±1.2 mg/dL were significantly (p < 0.01 higher in the study subjects than the comparison group (7.6±2.4, 0.9±0.2, and 3.9±1.1 mg/dL, respectively. The mean±SD creatinine clearance was significantly (p = 0.002 lower in the study subjects than the comparison group (98.9±21.3 vs. 108.2±25.2 mL/min/1.72 m2. Serum uric acid level correlated positively with serum creatinine (r = 0.134 and negatively with GFR (r = ‑0.151. Conclusion: People with occupational lead exposure are at risk of developing hyperuricemia and renal impairment.

  3. Lead and Zinc pollution of soils in the Kabwe lead-zinc mining area

    International Nuclear Information System (INIS)

    Musonda, B.M.; Tembo, F

    2004-01-01

    Lead and Zinc pollution of soils related to mining activities in Kabwe district is one of the major environmental problems in Zambia today. In this study, we investigated the distribution of lead and zinc in topsoil and subsoil. Samples were collected from topsoil(0-20cm) and subsoil(20-50cm)at predetermined sites using a 5km x 5km regional grid and a 500m x 500m local grid. After preparation 260 local and 200 regional samples were analysed for heavy metals by atomic absorption spectrophotometry. The background levels of cold HNO3 extractable lead and zinc are 50mg/kg and 70mg/kg respectively. The degree of Pb and Zn contamination of the soils varies with proximity of the soils to Kabwe mining centre. The content of Pb and Zn in topsoil that is very close to the mine is up to 1.6% and 3.9% respectively while soils that are very far from the mine generally contain less than 10mg/kg Pb and 20mg/kg Zn. The heavy metal contamination patterns in soils adjacent to the mine have been formed by wind dispersion of particulate matter and dry deposition. The risk of exposure of humans to lead and zinc is very high in areas that are adjacent to the mining centre. (author)

  4. Nb 3d and O 1s core levels and chemical bonding in niobates

    International Nuclear Information System (INIS)

    Atuchin, V.V.; Kalabin, I.E.; Kesler, V.G.; Pervukhina, N.V.

    2005-01-01

    A set of available experimental data on binding energies of Nb 3d 5/2 and O 1s core levels in niobates has been observed with using energy difference (O 1s-Nb 3d 5/2 ) as a robust parameter for compound characterization. An empirical relationship between (O 1s-Nb 3d 5/2 ) values measured with XPS for Nb 5+ -niobates and mean chemical bond length L(Nb-O) has been discussed. A range of (O 1s-Nb 3d 5/2 ) values possible in Nb 5+ -niobates has been defined. An energy gap ∼1.4-1.8 eV is found between (O 1s-Nb 3d 5/2 ) values reasonable for Nb 5+ and Nb 4+ states in niobates

  5. Laser-assisted lead extraction: the European experience.

    Science.gov (United States)

    Kennergren, C; Bucknall, C A; Butter, C; Charles, R; Fuhrer, J; Grosfeld, M; Tavernier, R; Morgado, T B; Mortensen, P; Paul, V; Richter, P; Schwartz, T; Wellens, F

    2007-08-01

    The aim of this study is to investigate the safety and effectiveness of Excimer laser-assisted lead extraction in Europe. The final European multi-centre study experience is presented. The Excimer is a cool cutting laser (50 degrees C) with a wavelength of 308 nm. The energy is emitted from the tip of a flexible sheath and is absorbed by proteins and lipids, 64% of the energy is absorbed at a tissue depth of 0.06 mm. The sheath is positioned over the lead, and the fibrosis surrounding the lead is vaporized while advancing the sheath without damaging other leads. From August 1996 to March 2001, 383 leads (170 atrial, 213 ventricular) in 292 patients (mean age 61.6 years, range 13-96) were extracted at 14 European centres. Mean implantation time was 74 months (3-358). Most frequent indications were pocket infection (26%), non-functional leads (21%), patient morbidity (21%), septicaemia or endocarditis (14%), erosion (5%), and lead interference (8%). Median extraction time was 15 min (1-300). Complete extraction was achieved in 90.9% of the leads and partial extraction in 3.4%. Extraction failed in 5.7% of the leads. Major complications = perforations caused 10/22 (3.4/5.7%) of the failures. Most partially extracted patients were considered clinically successful, as only minor lead parts without clinical significance were left. Femoral non-laser technique was used to remove 8/12 of the non-complication failures. The total complication rate, including five minor complications (1.7%), was 5.1%. No in-hospital mortality occurred. Pacing and implantable cardioverter-defibrillator leads can safely, effectively, and predictably be extracted. Open-heart extractions can be limited to special cases. The results indicate that the traditional policy of abandoning redundant leads, instead of removing them, may be obsolete in many patients.

  6. Role of lead as modifier on the properties of lead iron phosphate nuclear waste glasses

    International Nuclear Information System (INIS)

    Hazra, G.; Mitra, P.; Das, T.

    2011-01-01

    Lead-iron phosphate glasses are a promising new waste form for the safe immobilization of both high level defence and high level commercial radioactive waste for long term disposal. Lead iron phosphate glasses have several advantages such as lower aqueous corrosion rate, lower processing temperature etc. (author)

  7. Dietary exposure to lead in the Netherlands

    NARCIS (Netherlands)

    Boon PE; te Biesebeek JD; van Donkersgoed G; VVH; V&Z

    2017-01-01

    Uptake from the soil is the main route by which lead ends up in food. Lead in soil has its origin in both natural and anthropogenic sources. The lead concentration in food has decreased over the last decennia by the use of unleaded petrol and paint, and the replacement of lead water pipes.

  8. Lead deposit on vegetation growing along highways traveled by automobiles. Milk cow feeding experiments with hay contaminated with lead

    Energy Technology Data Exchange (ETDEWEB)

    Bovay, E

    1971-03-01

    Measurements conducted in Switzerland from 1967 through 1970 revealed that vegetation growing along highways contained lead in concentrations in excess of 100 ppm. Although the amounts of lead in vegetation rapidly decrease with distance from the highway, lead can be detected up to a distance of about 100 M. The rate and extent of dispersion of lead particles depended on seasonal orographic and/or meteorological conditions. Lead retention by different plant organs is governed by their nature and composition. Plants with large hairy leaves or leaves with a rough surface accumulate much more lead than plants with smooth leaves. From 35-65% of the plant tissue lead content can be removed by thorough washing, an indication that the contamination consists for the most part in a surface deposit. But plant roots growing in lead-contaminated soil absorb the element, even if present in a relatively insoluble form. In spite of these observations, no symptoms of plant disease or a decrease in crop yield has been noted. High tightly growing hedges of perennials (pine or fir) markedly reduce the dispersion of exhaust gases. Feeding trials with mild cows involving hay harvested along highways demonstrated that a high percentage of the lead ingested with the fodder was eliminated. Some organs like bones, kidneys, and the liver accumulated large quantities of lead (up to 21-fold quantities). After four weeks on the contaminated hay, the lead content in milk quadrupled. The cows ingested 1300 mg lead daily with contaminated fodder containing 99 ppm Pb. Toxic symptoms in cattle and horses do not appear until an ingestion level of about 2200 mg Pb/day is reached. 36 references.

  9. Dietary and inhalation intake of lead and estimation of blood lead levels in adults and children in Kanpur, India.

    Science.gov (United States)

    Sharma, Mukesh; Maheshwari, Mayank; Morisawa, S

    2005-12-01

    This research was initiated to study lead levels in various food items in the city of Kanpur, India, to assess the dietary intake of lead and to estimate blood lead (PbB) levels, a biomarker of lead toxicity. For this purpose, sampling of food products, laboratory analysis, and computational exercises were undertaken. Specifically, six food groups (leafy vegetables, nonleafy vegetables, fruits, pulses, cereals, and milk), drinking water, and lead air concentration were considered for estimating lead intake. Results indicated highest lead content in leafy vegetables followed by pulses. Fruits showed low lead content and drinking water lead levels were always within tolerable limits. It was estimated that average daily lead intake through diet was about 114 microg/day for adults and 50 microg/day in children; tolerable limit is 250 microg/day for adults and 90 microg/day for children. The estimated lead intakes were translated into the resultant PbB concentrations for children and adults using a physiologically-based pharmacokinetic (PBPK) model. Monte Carlo simulation of PbB level variations for adults showed that probability of exceeding the tolerable limit of PbB (i.e.,10 microg/dL) was 0.062 for the pre-unleaded and 0.000328 for the post-unleaded gasoline period. The probability of exceeding tolerable limits in PbB level was reduced by a factor of 189 in the post-unleaded scenario. The study also suggested that in spite of the introduction of unleaded gasoline, children continue to be at a high risk (probability of exceeding 10 microg/dL = 0.39) because of a high intake of lead per unit body weight.

  10. Lead distribution in soils impacted by a secondary lead smelter: Experimental and modelling approaches

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Arnaud R., E-mail: arnaud.schneider@univ-reims.fr [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France); Cancès, Benjamin; Ponthieu, Marie [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France); Sobanska, Sophie [Laboratoire de Spectrochimie IR et Raman, UMR-CNRS 8516, Bât. C5 Université de Lille I, 59655 Villeneuve d' Ascq Cedex (France); Benedetti, Marc F. [Institut de Physique du Globe de Paris, Sorbonne Paris Cité, Université Paris Diderot, UMR 7154, CNRS, F-75005 Paris (France); Pourret, Olivier [HydrISE, Institut Polytechnique LaSalle Beauvais, FR-60000 Beauvais (France); Conreux, Alexandra; Calandra, Ivan; Martinet, Blandine; Morvan, Xavier; Gommeaux, Maxime; Marin, Béatrice [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France)

    2016-10-15

    Smelting activities are one of the most common sources of trace elements in the environment. The aim of this study was to determine the lead distribution in upper horizons (0–5 and 5–10 cm) of acidic soils in the vicinity of a lead-acid battery recycling plant in northern France. The combination of chemical methods (sequential extractions), physical methods (Raman microspectroscopy and scanning electron microscopy with an energy dispersive spectrometer) and multi-surface complexation modelling enabled an assessment of the behaviour of Pb. Regardless of the studied soil, none of the Pb-bearing phases commonly identified in similarly polluted environments (e.g., anglesite) were observed. Lead was mainly associated with organic matter and manganese oxides. The association of Pb with these soil constituents can be interpreted as evidence of Pb redistribution in the studied soils following smelter particle deposition. - Highlights: • Lead behavior was studied in smelter impacted soils. • A combination of experimental methods and modelling was employed. • Pb was mainly associated with organic matter and to a lesser degree with Mn oxides. • Pb was redistributed in soils after smelter particle deposition.

  11. Lead distribution in soils impacted by a secondary lead smelter: Experimental and modelling approaches

    International Nuclear Information System (INIS)

    Schneider, Arnaud R.; Cancès, Benjamin; Ponthieu, Marie; Sobanska, Sophie; Benedetti, Marc F.; Pourret, Olivier; Conreux, Alexandra; Calandra, Ivan; Martinet, Blandine; Morvan, Xavier; Gommeaux, Maxime; Marin, Béatrice

    2016-01-01

    Smelting activities are one of the most common sources of trace elements in the environment. The aim of this study was to determine the lead distribution in upper horizons (0–5 and 5–10 cm) of acidic soils in the vicinity of a lead-acid battery recycling plant in northern France. The combination of chemical methods (sequential extractions), physical methods (Raman microspectroscopy and scanning electron microscopy with an energy dispersive spectrometer) and multi-surface complexation modelling enabled an assessment of the behaviour of Pb. Regardless of the studied soil, none of the Pb-bearing phases commonly identified in similarly polluted environments (e.g., anglesite) were observed. Lead was mainly associated with organic matter and manganese oxides. The association of Pb with these soil constituents can be interpreted as evidence of Pb redistribution in the studied soils following smelter particle deposition. - Highlights: • Lead behavior was studied in smelter impacted soils. • A combination of experimental methods and modelling was employed. • Pb was mainly associated with organic matter and to a lesser degree with Mn oxides. • Pb was redistributed in soils after smelter particle deposition.

  12. Serum Neuron-Specific Enolase, Biogenic Amino-Acids and Neurobehavioral Function in Lead-Exposed Workers from Lead-Acid Battery Manufacturing Process

    OpenAIRE

    K Ravibabu; T Barman; HR Rajmohan

    2015-01-01

    Background: The interaction between serum neuron-specific enolase (NSE), biogenic amino-acids and neurobehavioral function with blood lead levels in workers exposed to lead form lead-acid battery manufacturing process was not studied. Objective: To evaluate serum NSE and biogenic amino-acids (dopamine and serotonin) levels, and neurobehavioral performance among workers exposed to lead from lead-acid storage battery plant, and its relation with blood lead levels (BLLs). Methods: In a c...

  13. Absorption and reflectivity of the lithium niobate surface masked with a graphene layer

    Directory of Open Access Journals (Sweden)

    O. Salas

    2017-01-01

    Full Text Available We performed simulations of the interaction of a graphene layer with the surface of lithium niobate utilizing density functional theory and molecular dynamics at 300K and atmospheric pressure. We found that the graphene layer is physisorbed on the lithium niobate surface with an adsorption energy of -0.8205 eV/(carbon-atom. Subsequently, the energy band structure, the optical absorption and reflectivity of the new system were calculated. We found important changes in these physical properties with respect to the corresponding ones of a graphene layer and of a lithium niobate crystal.

  14. Role of magnesium on the biomimetic deposition of calcium phosphate

    Science.gov (United States)

    Sarma, Bimal K.; Sarma, Bikash

    2016-10-01

    Biomimetic depositions of calcium phosphate (CaP) are carried out using simulated body fluid (SBF), calcifying solution and newly developed magnesium containing calcifying solution. Calcium phosphate has a rich phase diagram and is well known for its excellent biocompatibility and bioactivity. The most common phase is hydroxyapatite (HAp), an integral component of human bone and tooth, widely used in orthopedic and dental applications. In addition, calcium phosphate nanoparticles show promise for the targeted drug delivery. The doping of calcium phosphate by magnesium, zinc, strontium etc. can change the protein uptake by CaP nanocrystals. This work describes the role of magnesium on the nucleation and growth of CaP on Ti and its oxide substrates. X-ray diffraction studies confirm formation of HAp nanocrystals which closely resemble the structure of bone apatite when grown using SBF and calcifying solution. It has been observed that magnesium plays crucial role in the nucleation and growth of calcium phosphate. A low magnesium level enhances the crystallinity of HAp while higher magnesium content leads to the formation of amorphous calcium phosphate (ACP) phase. Interestingly, the deposition of ACP phase is rapid when magnesium ion concentration in the solution is 40% of calcium plus magnesium ions concentration. Moreover, high magnesium content alters the morphology of CaP films.

  15. Lead poisoning after gunshot wound

    Directory of Open Access Journals (Sweden)

    Paulo Roberto de Madureira

    2000-05-01

    Full Text Available CONTEXT: Despite the absence of symptoms in the majority of patients carrying lead bullet fragments in their bodies, there needs to be an awareness of the possible signs and symptoms of lead intoxication when bullets are lodged in large joints like knees, hips and shoulders. Such patients merit closer follow-up, and even surgical procedure for removing the fragments. OBJECTIVE: To describe a patient who developed clinical lead intoxication several years after a gunshot wound. DESIGN: Case report. CASE REPORT: A single white 23-year-old male, regular job as a bricklayer, with a history of chronic alcohol abuse, showed up at the emergency department complaining of abdominal pain with colic, weakness, vomiting and diarrhea with black feces. All the symptoms had a duration of two to three weeks, and had been recurrent for the last two years, with calming during interval periods of two to three weeks. Abdominal radiograms showed a bullet lodged in the left hip, with a neat bursogram of the whole synovial capsule. A course of chelating treatment using calcium versenate (EDTACaNa2 intravenously was started. After the chelation therapy the patient had recurrence of his symptoms and a radical solution for the chronic mobilization of lead was considered. A hip arthroplasty procedure was performed, leading to complete substitution of the left hip.

  16. Design chart of optimum current leads

    International Nuclear Information System (INIS)

    Ishibashi, K.; Katase, A.; Maechata, K.

    1986-01-01

    The heat flow through current leads is one of major heat losses in a superconducting magnet system. To reduce the heat flow, current leads have been optimized in a complex way by varying such quantities as conductor length, cross-sectional area, heat transfer coefficient and cooling perimeter. Therefore, this study is made to simplify the design procedure, and to explain the general characteristics of the current leads. A new combined parameter which takes turbulent flow into account is introduced in the present work to enable us to draw a useful design chart. This chart gives, to a wide variety of current leads, detailed information about the optimum design-viz. geometric dimensions, heat flow into liquid helium, and pressure drop of the cooling gas. Change of the cross-sectional area along the conductor may improve the current lead performance. The effects of this area change are examined in detail

  17. Solid-state epitaxial effects in structurally diphasic xerogel of Pb(Mg1/3Nb2/3)O3

    International Nuclear Information System (INIS)

    Ravindranathan, P.; Komarneni, S.; Roy, R.

    1990-01-01

    Lead magnesium niobate (PMN), Pb(Mg 1/3 Nb 2/3 )O 3 , with perovskite structure has been prepared using structurally diphasic PMN gels. The diphasic gels were made using various concentrations of perovskite PMN seeds. The unseeded gel calcined at 775 degrees C for 2 h gave ∼ 98% of perovskite PMN phase. The use of 1% PMN perovskite seed not only led to a pure perovskite phase but also lowered the crystallization temperature of these gels by about 75 degrees C. These results show that isostructural seeding helps to lower the crystallization temperature of perovskite PMN phase

  18. X-ray protective clothing. Does DIN 6857-1 allow an objective comparison between lead-free and lead-composite materials?

    International Nuclear Information System (INIS)

    Eder, H.; Schlattl, H.; Hoeschen, C.

    2010-01-01

    Purpose: The validity of DIN 6857-1 to establish lead equivalence for protective clothing is evaluated by Monte Carlo simulations and measurements. Materials and Methods: Commercially available protective clothing made of lead, lead-free and lead-composite materials has been tested regarding its protective efficacy. The analysis has been performed on the one hand in accordance with the test conditions described in the manufacturing standard DIN EN 61331-3 and on the other hand following the new DIN 6857-1 standard. Additionally, measurements have been carried out under simulated patient conditions by using an Alderson-Rando phantom. Results: Following DIN EN 61331-3, the lead-free protective clothing achieved the required protective efficacy only at a restricted tube-voltage range. The test according to DIN 6857-1 showed that the protective criteria were fulfilled only by one lead-composite apron, but not by the three lead-free aprons examined. Thus, in order to guarantee the same protection as lead between 50 and 120 kV, the conditions of DIN 6857-1 must be fulfilled. Conclusion: A modification of DIN EN 61331-3 to account for secondary radiation is strongly advised in the case of lead-free materials. In summary, most of the protective lead-free aprons in use should be used with care, particularly for examinations with a high dose. (orig.)

  19. Detection of leaded-gasoline usage in catalyst-equipped vehicles: a gamma-ray transmission guage for measuring catalytic converter lead contamination

    International Nuclear Information System (INIS)

    Schneider, E.W.

    1982-01-01

    A gamma-ray transmission gauge has been developed for measuring the accumulation of lead inside the catalytic converters of vehicles operated on leaded gasoline. This nondestructive inspection system relates the amount of gamma radiation passing through the catalytic converter to the mass concentration of lead contained in the catalyst bed. Field studies have shown that vehicle usage of 200 L of leaded gasoline (0.34 g of Pb/L) can be detected at the 95% confidence level. Based on tests with one vehicle burning 1000 L of leaded gasoline, the accumulation rate of lead on the catalytic converter was relatively constant, accounting for 45% of the total lead consumed. Subsequent usage of unleaded gasoline resulted in no significant loss of lead from the catalytic converter

  20. Lead sources in human diet in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Johansen, Poul; Mulvad, Gert

    2004-01-01

    Although blood lead levels have declined in Greenland, they are still elevated despite the fact that lead levels in the Greenland environment are very low. Fragments of lead shot in game birds have been suggested as an important source of dietary exposure, and meals of sea birds, particularly eider......, contain high concentrations of lead. In a cross-sectional population survey in Greenland in 1993-1994, blood lead adjusted for age and sex was found to be associated with the reported consumption of sea birds. Participants reporting less than weekly intake of sea birds had blood lead concentrations...... of approximately 75 microg/L, whereas those who reported eating sea birds several times a week had concentrations of approximately 110 microg/L, and those who reported daily intake had concentrations of 170 microg/L (p = 0.01). Blood lead was not associated with dietary exposure to other local or imported food...

  1. 41 CFR 101-42.1102-7 - Lead-containing paint and items bearing lead-containing paint.

    Science.gov (United States)

    2010-07-01

    ... be in conformance with Occupational Safety and Health Administration (OSHA) regulations at 29 CFR... property requested herein shall be used only as specified in 16 CFR 1303.3 and in no case shall be...) Abandonment and destruction. In no case shall lead-containing paint or consumer products bearing lead...

  2. Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Macquarie University, North Ryde NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113 (Australia); Anderson, Phil [Information and Statistics Group, Australian Institute of Health and Welfare, Canberra ACT 2601 (Australia); Faculty of Health, University of Canberra, Canberra ACT 2601 (Australia); Taylor, Alan [Department of Psychology, Macquarie University, Sydney NSW 2109 (Australia)

    2013-10-15

    Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10

  3. Lead pollution of road-side vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Quinche, J P; Zuber, R; Bovay, E

    1969-01-01

    In Switzerland, investigations have been made in 1967/1968 concerning the distribution of lead issued from the antiknocking additive of petrol. Observations show that the deposits in meadows in the immediate surrounding (first meter) of roads and highways with high traffic density were especially high (50-100 ppm in dry matter). The pollution is still perceptible even as far as 50 meters from the road. Moreover, during the summer (July and August), a second zone of high lead accumulation (more than 100 ppm) was detected 50 to 100 m from the road, particularly along the highways. This probably is caused by certain climatic conditions and the increase of traffic volume. With regard to fruits, only the downy species (e.g. apricots, peaches) retain some quantities of lead on their skin. Vegetables with large leaves, e.g. lettuce, spinach, and particularly vegetables with definite dissected foliage, such as fennel and parsley, may accumulate relatively high quantities of lead. According to some authors, up to 50 percent of these deposits may be eliminated by washing with water. Conversely, root vegetables (e.g. carrots, onions) do not show a perceptible lead contamination. Likewise the flesh of fruits is not markedly polluted by lead. Trials with foddering milk cows using hay harvested along a highway are not yet analyzed. The results from these trials should permit determining the proportion of lead which remains in the tissues (meat etc.) or passes over into the milk.

  4. Natural convection in enclosures containing lead-bismuth and lead

    International Nuclear Information System (INIS)

    Dzodzo, M.; Cuckovic-Dzodzo, D.

    2001-01-01

    The design of liquid metal reactors such as Encapsulated Nuclear Heat Source (ENHS) which are based predominantly on the flow generated by natural convection effects demands knowledge of velocity and temperature fields, distribution of the local Nusselt numbers and values of the average Nusselt numbers for small coolant velocity regimes. Laminar natural convection in rectangular enclosures with different aspect ratios, containing lead-bismuth and lead is studied numerically in this paper. The numerical model takes into account variable properties of the liquid metals. The developed correlation for average Nusselt numbers is presented. It is concluded that average Nusselt numbers are lower than in 'normal' fluids (air, water and glycerol) for the same values of Rayleigh numbers. However, the heat flux, which can be achieved, is greater due to the high thermal conductivity of liquid metals. Some specific features of the flow fields generated by natural convection in liquid metals are presented. Their consequences on the design of heat exchangers for liquid metals are discussed. An application of the obtained results to the design of a new type of steam generator, which integrates the intermediate heat exchanger and secondary pool functions of the ENHS reactor, is presented. (authors)

  5. Short- and Long-Term Lead Release after Partial Lead Service Line Replacements in a Metropolitan Water Distribution System.

    Science.gov (United States)

    Deshommes, Elise; Laroche, Laurent; Deveau, Dominique; Nour, Shokoufeh; Prévost, Michèle

    2017-09-05

    Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.

  6. X-linked immunodeficiency with magnesium defect, Epstein-Barr virus infection, and neoplasia disease: a combined immune deficiency with magnesium defect.

    Science.gov (United States)

    Ravell, Juan; Chaigne-Delalande, Benjamin; Lenardo, Michael

    2014-12-01

    To describe the role of the magnesium transporter 1 (MAGT1) in the pathogenesis of 'X-linked immunodeficiency with magnesium defect, Epstein-Barr virus (EBV) infection, and neoplasia' (XMEN) disease and its clinical implications. The magnesium transporter protein MAGT1 participates in the intracellular magnesium ion (Mg) homeostasis and facilitates a transient Mg influx induced by the activation of the T-cell receptor. Loss-of-function mutations in MAGT1 cause an immunodeficiency named 'XMEN syndrome', characterized by CD4 lymphopenia, chronic EBV infection, and EBV-related lymphoproliferative disorders. Patients with XMEN disease have impaired T-cell activation and decreased cytolytic function of natural killer (NK) and CD8 T cells because of decreased expression of the NK stimulatory receptor 'natural-killer group 2, member D' (NKG2D). Patients may have defective specific antibody responses secondary to T cell dysfunction, but B cells have not been shown to be directly affected by mutations in MAGT1. XMEN disease has revealed a novel role for free intracellular magnesium in the immune system. Further understanding of the MAGT1 signaling pathway may lead to new diagnostic and therapeutic approaches.

  7. Resolution of lead-210 chronologies in lake sediments: problems of mid-core fluctuations in lead-210/radium-226 ratios

    Energy Technology Data Exchange (ETDEWEB)

    Haworth, R. [New England Univ., Armidale, NSW (Australia). Dept. of Geography; Heijnis, H. [Australian Inst. of Nuclear Science and Engineering, Lucas Heights, NSW (Australia)

    1997-12-31

    With a range in excess of 150 years under optimum conditions, lead-210 dating represents a valuable tool for studying recent human impacts on the environment, particularly the effects of European settlement in Australia. It is therefore also useful for establishing the start of the pre-European record in a sediment profile. Despite these advantages, there are some unresolved problems that prevent the full potential of an atmospherically-derived lead-210 profile being extended as far into the past as the activity signal allows. lead 210 has a half-life of 22.26 years, and a capacity to precipitate and be adsorbed by terrestrial material, particularly lake and marine sediments. This out-of-phase (or unsupported) lead-210 thus returns to a specific terrigenous location where it is added to the lead- 210 formed continuously in situ from the local radium-226 (equivalent to supported lead-210). Dating is based on the measurement of the decline of this unsupported lead-210 against the equilibrium ratio of in situ lead-210/radium-226. Paper no. 13; Extended abstract. 2 refs., 1 fig.

  8. Resolution of lead-210 chronologies in lake sediments: problems of mid-core fluctuations in lead-210/radium-226 ratios

    International Nuclear Information System (INIS)

    Haworth, R.

    1997-01-01

    With a range in excess of 150 years under optimum conditions, lead-210 dating represents a valuable tool for studying recent human impacts on the environment, particularly the effects of European settlement in Australia. It is therefore also useful for establishing the start of the pre-European record in a sediment profile. Despite these advantages, there are some unresolved problems that prevent the full potential of an atmospherically-derived lead-210 profile being extended as far into the past as the activity signal allows. lead 210 has a half-life of 22.26 years, and a capacity to precipitate and be adsorbed by terrestrial material, particularly lake and marine sediments. This out-of-phase (or unsupported) lead-210 thus returns to a specific terrigenous location where it is added to the lead- 210 formed continuously in situ from the local radium-226 (equivalent to supported lead-210). Dating is based on the measurement of the decline of this unsupported lead-210 against the equilibrium ratio of in situ lead-210/radium-226

  9. Narrow Lead Aprons under Medical Fluoroscopy Procedures

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    2014-01-01

    Lead aprons are the major protective item of the medical staff whose work involves x-ray exposure. Heart catheterization and angiography procedures represent the most common exposures of the medical staff. The lead equivalent thickness of lead aprons worn by the medical staff is defined by many national standards. The frontal side of the aprons should be 0.25 mm lead equivalent at working conditions under 100 kV, 0.35 mm for working conditions above 100 kV, and 0.5 mm for heart catheterization and angiography. The back side of the body needs less protection and usually is covered by 0.25 mm of lead equivalent. The lead equivalent thickness is defined at the 80 kV level

  10. Lead in Glasgow street dirt and soil

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J G [Univ. of Glasgow; Lyon, T D.B.

    1977-07-01

    The levels of lead in city street dirt and in soil from various locations in Glasgow were investigated during spring 1976. Lead concentrations in street dirt ranged from 150 to 2300 ppM, mean 960 ppM, and were significantly elevated with respect to the observed ''natural'' level of 78 ppM. Lead derived from anti-knock compounds in petrol and introduced to the environment via automobile exhausts was clearly implicated as the main source of lead pollution in a series of soil lead measurements at the centre and periphery of eight Glasgow parks. Various chemical leaching techniques were employed and compared. Less than 5 percent of street dirt and soil lead was found to be associated with the organic phase.

  11. The Structural Engineering Strategy for Photonic Material Research and Device Development

    Directory of Open Access Journals (Sweden)

    Yalin Lu

    2007-01-01

    Full Text Available A new structural engineering strategy is introduced for optimizing the fabrication of arrayed nanorod materials, optimizing superlattice structures for realizing a strong coupling, and directly developing nanophotonic devices. The strategy can be regarded as “combinatorial” because of the high efficiency in optimizing structures. In this article, this strategy was applied to grow ZnO nanorod arrays, and to develop a new multifunctional photodetector using such nanorod arrays, which is able to simultaneously detect power, energy, and polarization of an incident ultraviolet radiation. The strategy was also used to study the extraordinary dielectric behavior of relaxor ferroelectric lead titanate doped lead magnesium niobate heterophase superlattices in the terahertz frequencies, in order to investigate their dielectric polariton physics and the potential to be integrated with tunable surface resonant plasmonics devices.

  12. High temperature superconductor current leads

    International Nuclear Information System (INIS)

    Zeimetz, B.; Liu, H.K.; Dou, S.X.

    1996-01-01

    Full text: The use of superconductors in high electrical current applications (magnets, transformers, generators etc.) usually requires cooling with liquid Helium, which is very expensive. The superconductor itself produces no heat, and the design of Helium dewars is very advanced. Therefore most of the heat loss, i.e. Helium consumption, comes from the current lead which connects the superconductor with its power source at room temperature. The current lead usually consists of a pair of thick copper wires. The discovery of the High Temperature Superconductors makes it possible to replace a part of the copper with superconducting material. This drastically reduces the heat losses because a) the superconductor generates no resistive heat and b) it is a very poor thermal conductor compared with the copper. In this work silver-sheathed superconducting tapes are used as current lead components. The work comprises both the production of the tapes and the overall design of the leads, in order to a) maximize the current capacity ('critical current') of the superconductor, b) minimize the thermal conductivity of the silver clad, and c) optimize the cooling conditions

  13. Mortality study of lead workers

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W C; Gaffey, W R

    1975-01-01

    The mortality of 7,032 men employed for one or more years in lead production facilities or battery plants was followed over a 23-year period, 1947-70. Lead absorption in many of these men was greatly in excess of currently accepted standards based upon urinary and blood lead concentrations available for a portion of the group. There were 1,356 deaths reported. The standardized mortality ratio (SMR) for all causes was 107 for smelter workers and 99 for battery plant workers. Death from neoplasms were in slight excess in smelters, but not significantly increased in battery plants. There were no excess deaths from kidney tumors. The SMR for cardiovascular-renal disease was 96 for smelter workers and 101 for battery plant workers. There was definitely no excess in deaths from either stroke or hypertensive heart disease; however, deaths classified as other hypertensive disease and unspecified nephritis or renal sclerosis were higher than expected. The life expectancy of lead workers was calculated to be approximately the same as that of all U.S. males.

  14. Editorial: Lead Risk Assessment and Health Effects

    Directory of Open Access Journals (Sweden)

    Howard W. Mielke

    2016-06-01

    Full Text Available In 1980, Clair C. Patterson stated: “Sometime in the near future it probably will be shown that the older urban areas of the United States have been rendered more or less uninhabitable by the millions of tons of poisonous industrial lead residues that have accumulated in cities during the past century”. We live in the near future about which this quote expressed concern. This special volume of 19 papers explores the status of scientific evidence regarding Dr. Patterson’s statement on the habitability of the environments of communities. Authors from 10 countries describe a variety of lead issues in the context of large and small communities, smelter sites, lead industries, lead-based painted houses, and vehicle fuel treated with lead additives dispersed by traffic. These articles represent the microcosm of the larger health issues associated with lead. The challenges of lead risk require a concerted global action for primary prevention.

  15. Update on Recovering Lead From Scrap Batteries

    Science.gov (United States)

    Cole, E. R.; Lee, A. Y.; Paulson, D. L.

    1985-02-01

    Previous work at the Bureau of Mines Rolla Research Center, U.S. Department of the Interior, resulted in successful development of a bench-scale, combination electrorefining-electrowinning method for recycling lead from scrap batteries by using waste fluosilicic acid (H2SiF6) as electrolyte.1,2 This paper describes larger scale experiments. Prior attempts to electrowin lead failed because large quantities of insoluble lead dioxide were deposited on the anodes at the expense of lead deposition on the cathodes. A major breakthrough was achieved with the discovery that lead dioxide formation at the anodes is prevented by adding a small amount of phosphorus to the electrolyte. The amount of PbO2 formed on the anodes during lead electrowinning was less than 1% of the total lead deposited on the cathodes. This work recently won the prestigious IR·100 award as one of the 100 most significant technological advances of 1984.

  16. Occurrence of lead-related symptoms below the current occupational safety and health act allowable blood lead levels.

    Science.gov (United States)

    Rosenman, Kenneth D; Sims, Amy; Luo, Zhehui; Gardiner, Joseph

    2003-05-01

    To determine the occurrence of symptoms of lead toxicity at levels below the current allowable Occupational Safety and Health Act blood lead level of 50 micrograms/dL, standardized telephone interviews were conducted of individuals reported to a statewide laboratory-based surveillance system. Four hundred and ninety-seven, or 75%, of the eligible participants were interviewed. Gastrointestinal, musculoskeletal, and nervous system symptoms increased with increasing blood lead levels. Nervous, gastrointestinal, and musculoskeletal symptoms all began to be increased in individuals with blood leads between 30-39 micrograms/dL and possibly at levels as low as 25-30 micrograms/dL for nervous system symptoms. The results of this study of increased symptoms are consistent with and provide added weight to previous results showing subclinical changes in the neurologic and renal systems and sperm counts at blood lead levels currently allowed by the Occupational Safety and Health Act.

  17. Drinking Water Contamination Due To Lead-based Solder

    Science.gov (United States)

    Garcia, N.; Bartelt, E.; Cuff, K. E.

    2004-12-01

    The presence of lead in drinking water creates many health hazards. Exposure to lead-contaminated water can affect the brain, the central nervous system, blood cells, and kidneys, causing such problems as mental retardation, kidney disease, heart disease, stroke, and death. One way in which lead can contaminate our water supply is through the use of lead solder to join pipes. Lead solder was widely used in the past because of its ease of application as well as its low cost. Lead contamination in residential areas has previously been found to be a particularly serious problem in first-draw samples, of water that has sat stagnant in pipes overnight. To investigate the time-dependence of drinking water lead contamination, we analyzed samples taken hourly of water exposed to lead solder. While our preliminary data was insufficient to show more than a rough correlation between time of exposure and lead concentration over short periods (1-3 hours), we were able to confirm that overnight exposure of water to lead-based solder results in the presence high levels of lead. We also investigated other, external factors that previous research has indicated contribute to increased concentrations of lead. Our analysis of samples of lead-exposed water at various pH and temperatures suggests that these factors can be equally significant in terms of their contribution to elevated lead concentration levels. In particular, water that is slightly corrosive appears to severely impact the solubility of lead. As this type of water is common in much of the Northeast United States, the presence of lead-based solder in residential areas there is especially problematic. Although lead-based solder has been banned since the 1980s, it remains a serious concern, and a practical solution still requires further research.

  18. Effect of lead exposure in children

    International Nuclear Information System (INIS)

    Khwaja, M.

    2005-01-01

    Increasing prosperity and population-growth in many developing countries are resulting in accelerated growth in population of vehicles and vehicle-kilometers traveled. In Pakistan also, the number of vehicles has jumped from 0.8 million to about 4.0 million within 20 years, showing an overall increase of more than 400%. Accordingly, the consumption of petrol (motor spirit) has increased from 828,670 metric tons to 1,189,042 metric tons. The high content of lead in petrol is a serious issue, as the end- product is the release of lead into the environment. In Pakistan, prior to July 2001, lead-content in petrol was reported to be as high as 0.35-0.84 gram per liter. The reported lead-levels in air (micrograms/cubic centimeter) in different cities of Pakistan are: Karachi (1980-81) 0.13-0.24; Peshawar (1994-95) 0.21-0.79; Lahore (1993-94) 0.15-8.36 and (1999-2000) 0.89-7.85 and Rawalpindi (1999-2000) 0.71-10.00, indicating the very alarming increase and high levels of lead in the ambient air, at the reported sites and time of monitoring. Children in developing countries, with dietary deficiencies, are very susceptible to lead poisoning. Special concern of lead-poisoning has been that lead is a neurotoxin and it impairs brain-development in children, even at levels that were considered safe. The overall mean BPbLs (micrograms per deciliter) among 900 (boys and girls) of three cities in Pakistan have been reported to be 22.8 +- 3.30, 19.00 +-6.48 and 2.30 +-0.19 (rural site). Details of these investigations and government national environmental action-plan (NEAP) are described and discussed in this paper, with special reference to clean air by providing clean fuel and taking other air-pollution control measures. (author)

  19. Lead content in household paints in India

    International Nuclear Information System (INIS)

    Kumar, Abhay; Gottesfeld, Perry

    2008-01-01

    Lead and its compounds are used in paints not only to impart colour but also to make it durable, corrosion resistant and to improve drying. Adverse health impacts of lead especially on children have led countries to restrict or ban its use in paints. While U.S. and other developed countries instituted measures to limit the use of lead in paints, some developing countries including India have failed to regulate their lead content. The present study was undertaken to determine the levels of lead in new latex (water-based) and enamel paints (oil-based) intended for residential use in India. A total of 69 paint samples (38 latex and 31 enamel samples) from six of the most popular brands were analysed for lead concentrations. While all latex paint samples contained low levels of lead, (i.e., well below 600 ppm as regulated by United States' Consumer Products Safety Commission) the enamel paint samples of all but one brand contained significant concentrations of lead, ranging up to 140,000 ppm. In fact 84% of the enamel paints tested exceeded 600 ppm whereas only 38 % of all samples (including latex and enamel types) exceeded this regulatory level

  20. Discriminating background from anthropogenic lead by isotopic methods

    International Nuclear Information System (INIS)

    Nelson, B.K.; O'Brien, H.E.

    1995-01-01

    The goal of this pilot project was to evaluate the practicality of using natural variations in the isotopic composition of lead to test for the presence of anthropogenic lead in soil, surface water and ground water. Complex chemical reactions in the environment may cause measured lead concentrations to be ambiguous indicators of anthropogenic lead component. The lead isotope tracer technique has the potential to identify both the presence and proportion of anthropogenic lead in the environment. The tested the lead isotope technique at Eielson Air Force Base, Alaska, on sources of suspected fuel contamination. Although the results are specific to this base, the general technique of using lead isotopes to trace the movement of anthropogenic lead is applicable to other CERCLA sites. The study had four objectives: (1) characterize the natural lead isotope composition of bedrock, stream sediment and soils; (2) characterize the isotopic composition of the contaminant lead derived from fuel; (3) evaluate the sensitivity of the isotopic method to distinguishing between anthropogenic and natural lead in soil and water samples and (4) evaluate the analytical feasibility and accuracy of the method at the Isotope Geochemistry Laboratory at the University of Washington