WorldWideScience

Sample records for lateral flow device

  1. Integrated Lateral Flow Device for Flow Control with Blood Separation and Biosensing

    Directory of Open Access Journals (Sweden)

    Veronica Betancur

    2017-12-01

    Full Text Available Lateral flow devices are versatile and serve a wide variety of purposes, including medical, agricultural, environmental, and military applications. Yet, the most promising opportunities of these devices for diagnosis might reside in point-of-care (POC applications. Disposable paper-based lateral flow strips have been of particular interest, because they utilize low-cost materials and do not require expensive fabrication instruments. However, there are constraints on tuning flow rates and immunoassays functionalization in papers, as well as technical challenges in sensors’ integration and concentration units for low-abundant molecular detection. In the present work, we demonstrated an integrated lateral flow device that applied the capillary forces with functionalized polymer-based microfluidics as a strategy to realize a portable, simplified, and self-powered lateral flow device (LFD. The polydimethylsiloxane (PDMS surface was rendered hydrophilic via functionalization with different concentrations of Pluronic F127. Controlled flow is a key variable for immunoassay-based applications for providing enough time for protein binding to antibodies. The flow rate of the integrated LFD was regulated by the combination of multiple factors, including Pluronic F127 functionalized surface properties and surface treatments of microchannels, resistance of the integrated flow resistor, the dimensions of the microstructures and the spacing between them in the capillary pump, the contact angles, and viscosity of the fluids. Various plasma flow rates were regulated and achieved in the whole device. The LFD combined the ability to separate high quality plasma from human whole blood by using a highly asymmetric plasma separation membrane, and created controlled and steady fluid flow using capillary forces produced by the interfacial tensions. Biomarker immunoglobulin G (IgG detection from plasma was demonstrated with a graphene nanoelectronic sensor integrated

  2. Improved sensitivity and limit-of-detection of lateral flow devices using spatial constrictions of the flow-path.

    Science.gov (United States)

    Katis, Ioannis N; He, Peijun J W; Eason, Robert W; Sones, Collin L

    2018-05-03

    We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  3. A paper-polymer centrifugal device for low-cost sample pre-concentration and colorimetric lateral flow assay enhancement

    CSIR Research Space (South Africa)

    Wiederoder, MS

    2016-10-01

    Full Text Available This study describes a novel hybrid paper-polymer centrifugal microfluidic device for pre-concentration of E.coli and lateral flow immunoassay enhancement for water quality verification. The device balances rotational centrifugal force...

  4. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Science.gov (United States)

    Cary, Robert E.

    2015-12-08

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  5. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Robert B.

    2018-04-17

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  6. Battery operated preconcentration-assisted lateral flow assay.

    Science.gov (United States)

    Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon

    2017-07-11

    Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.

  7. Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device.

    Science.gov (United States)

    Hegener, Michael A; Li, Hua; Han, Daewoo; Steckl, Andrew J; Pauletti, Giovanni M

    2017-09-01

    Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.

  8. Designs, formats and applications of lateral flow assay: A literature review

    Directory of Open Access Journals (Sweden)

    Muhammad Sajid

    2015-11-01

    Full Text Available This manuscript provides a brief overview of latest research involving the use of lateral flow assay for qualitative and quantitative analysis in different areas. The excellent features and versatility of detection formats make these strips an ideal choice for point of care applications. We outline and critically discuss detection formats, molecular recognition probes, labels, and detection systems used in lateral flow assay. Applications in different fields along with selected examples from the literature have been included to show analytical performance of these devices. At the end, we summarize accomplishments, weaknesses and future challenges in the area of lateral flow strips.

  9. Diagnosis of prosthetic joint infection with alpha-defensin using a lateral flow device: a multicentre study.

    Science.gov (United States)

    Berger, P; Van Cauter, M; Driesen, R; Neyt, J; Cornu, O; Bellemans, J

    2017-09-01

    The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS). A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery. Based on the MSIS criteria, 34 patients (28%) would have had a PJI, and 87 patients had no PJI. Testing with the lateral flow device had a sensitivity of 97.1% (95% confidence intervals (CI) 84.5 to 99.9) and a specificity of 96.6% (95% CI 90.3 to 99.2). The positive predictive value was 91.7% (95% CI 77.7% to 98.3), and the negative predictive value was 98.8% (95% CI 93.6 to 99.9). Receiver operator characteristics analysis demonstrated an area under the curve for the Synovasure test of 0.97 (95% CI 0.93 to 1.00). Our findings suggest that the Synovasure test has an excellent diagnostic performance to confirm or reject the diagnosis of a PJI. The results are promising for the care of the painful or problematic knee and hip joint arthroplasty and the test should be considered as part of the diagnostic toolbox for PJIs. Cite this article: Bone Joint J 2017;99-B:1176-82. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries.

    Science.gov (United States)

    Pilavaki, Evdokia; Demosthenous, Andreas

    2017-11-20

    Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  11. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries

    Directory of Open Access Journals (Sweden)

    Evdokia Pilavaki

    2017-11-01

    Full Text Available Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  12. An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen

    Directory of Open Access Journals (Sweden)

    Jacqueline M. Barnett

    2014-07-01

    Full Text Available We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM to quantify paramagnetic particles (PMPs in immunochromatographic (lateral flow assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format.

  13. Preliminary Study on the Damping Effect of a Lateral Damping Buffer under a Debris Flow Load

    Directory of Open Access Journals (Sweden)

    Zheng Lu

    2017-02-01

    Full Text Available Simulating the impact of debris flows on structures and exploring the feasibility of applying energy dissipation devices or shock isolators to reduce the damage caused by debris flows can make great contribution to the design of disaster prevention structures. In this paper, we propose a new type of device, a lateral damping buffer, to reduce the vulnerability of building structures to debris flows. This lateral damping buffer has two mechanisms of damage mitigation: when debris flows impact on a building, it acts as a buffer, and when the structure vibrates due to the impact, it acts as a shock absorber, which can reduce the maximum acceleration response and subsequent vibration respectively. To study the effectiveness of such a lateral damping buffer, an impact test is conducted, which mainly involves a lateral damping buffer attached to a two-degree-of-freedom structure under a simulated debris flow load. To enable the numerical study, the equation of motion of the structure along with the lateral damping buffer is derived. A subsequent parametric study is performed to optimize the lateral damping buffer. Finally, a practical design procedure is also provided.

  14. Paper-based enzymatic microfluidic fuel cell: From a two-stream flow device to a single-stream lateral flow strip

    Science.gov (United States)

    González-Guerrero, Maria José; del Campo, F. Javier; Esquivel, Juan Pablo; Giroud, Fabien; Minteer, Shelley D.; Sabaté, Neus

    2016-09-01

    This work presents a first approach towards the development of a cost-effective enzymatic paper-based glucose/O2 microfluidic fuel cell in which fluid transport is based on capillary action. A first fuel cell configuration consists of a Y-shaped paper device with the fuel and the oxidant flowing in parallel over carbon paper electrodes modified with bioelectrocatalytic enzymes. The anode consists of a ferrocenium-based polyethyleneimine polymer linked to glucose oxidase (GOx/Fc-C6-LPEI), while the cathode contains a mixture of laccase, anthracene-modified multiwall carbon nanotubes, and tetrabutylammonium bromide-modified Nafion (MWCNTs/laccase/TBAB-Nafion). Subsequently, the Y-shaped configuration is improved to use a single solution containing both, the anolyte and the catholyte. Thus, the electrolytes pHs of the fuel and the oxidant solutions are adapted to an intermediate pH of 5.5. Finally, the fuel cell is run with this single solution obtaining a maximum open circuit of 0.55 ± 0.04 V and a maximum current and power density of 225 ± 17 μA cm-2 and 24 ± 5 μW cm-2, respectively. Hence, a power source closer to a commercial application (similar to conventional lateral flow test strips) is developed and successfully operated. This system can be used to supply the energy required to power microelectronics demanding low power consumption.

  15. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    Directory of Open Access Journals (Sweden)

    Adrian Carrio

    2015-11-01

    Full Text Available Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  16. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    Science.gov (United States)

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  17. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  18. Development of a Rapid Immunochromatographic Lateral Flow Device Capable of Differentiating Phytase Expressed from Recombinant Aspergillus niger phyA2 and Genetically Modified Corn.

    Science.gov (United States)

    Zhou, Xiaojin; Hui, Elizabeth; Yu, Xiao-Lin; Lin, Zhen; Pu, Ling-Kui; Tu, Zhiguan; Zhang, Jun; Liu, Qi; Zheng, Jian; Zhang, Juan

    2015-05-06

    Phytase is a phosphohydrolase considered highly specific for the degradation of phytate to release bound phosphorus for animal consumption and aid in the reduction of environmental nutrient loading. New sources of phytase have been sought that are economically and efficiently productive including the construction of genetically modified (GM) phytase products designed to bypass the costs associated with feed processing. Four monoclonal antibodies (EH10a, FA7, AF9a, and CC1) raised against recombinant Aspergillus niger phyA2 were used to develop a highly specific and sensitive immunochromatographic lateral flow device for rapid detection of transgenic phytase, such as in GM corn. Antibodies sequentially paired and tested along lateral flow strips showed that the EH10a-FA7 antibody pair was able to detect the recombinant yeast-phytase at 5 ng/mL, whereas the AF9a-CC1 antibody pair to GM phytase corn was able to detect at 2 ng/mL. Concurrent to this development, evidence was revealed which suggests that antibody binding sites may be glycosylated.

  19. Lateral flow devices for nucleic acid analysis exploiting quantum dots as reporters

    Energy Technology Data Exchange (ETDEWEB)

    Sapountzi, Eleni A.; Tragoulias, Sotirios S.; Kalogianni, Despina P. [Department of Chemistry, University of Patras, GR-26504 Patras (Greece); Ioannou, Penelope C. [Department of Chemistry, University of Athens, GR-15771 Athens (Greece); Christopoulos, Theodore K., E-mail: tchrist@upatras.gr [Department of Chemistry, University of Patras, GR-26504 Patras (Greece); Institute of Chemical Engineering and High Temperature Processes, Foundation of Research and Technology Hellas, GR-26504 Patras (Greece)

    2015-03-15

    Highlights: • Dipstick tests for DNA hybridization assays and genotyping of single-nucleotide polymorphisms. • Use of quantum dots as reporters. • Visual detection without the need for expensive instrumentation. • Simplicity and low-cost of the assays. - Abstract: There is a growing interest in the development of biosensors in the form of simple lateral flow devices that enable visual detection of nucleic acid sequences while eliminating several steps required for pipetting, incubation and washing out the excess of reactants. In this work, we present the first dipstick-type nucleic acid biosensors based on quantum dots (QDs) as reporters. The biosensors enable sequence confirmation of the target DNA by hybridization and simple visual detection of the emitted fluorescence under a UV lamp. The ‘diagnostic’ membrane of the biosensor contains a test zone (TZ) and a control zone (CZ). The CZ always fluoresces in order to confirm the proper function of the biosensor. Fluorescence is emitted from the TZ, only when the specific nucleic acid sequence is present. We have developed two general types of QD-based nucleic acid biosensors, namely, Type I and Type II, in which the TZ consists of either immobilized streptavidin (Type I) or immobilized oligodeoxynucleotides (Type II). The control zone consists of immobilized biotinylated albumin. No purification steps are required prior to the application of the DNA sample on the strip. The QD-based nucleic acid biosensors performed accurately and reproducibly when applied to (a) the visual detection of PCR amplification products and (b) visual genotyping of single nucleotide polymorphisms (SNPs) in human genomic DNA from clinical samples. As low as 1.5 fmol of double-stranded DNA were clearly detected by naked eye and the dynamic range extended to 200 fmol. The %CV were estimated to be 4.3–8.2.

  20. Man-made flows from a fish's perspective: autonomous classification of turbulent fishway flows with field data collected using an artificial lateral line.

    Science.gov (United States)

    Tuhtan, Jeffrey A; Fuentes-Perez, Juan Francisco; Toming, Gert; Schneider, Matthias; Schwarzenberger, Richard; Schletterer, Martin; Kruusmaa, Maarja

    2018-05-25

    The lateral line system provides fish with advanced mechanoreception over a wide range of flow conditions. Inspired by the abilities of their biological counterparts, artificial lateral lines have been developed and tested exclusively under laboratory settings. Motivated by the lack of flow measurements taken in the field which consider fluid-body interactions, we built a fish-shaped lateral line probe. The device is outfitted with 11 high-speed (2.5 kHz) time-synchronized pressure transducers, and designed to capture and classify flows in fish passage structures. A total of 252 field measurements, each with a sample size of 132 000 discrete sensor readings were recorded in the slots and across the pools of vertical slot fishways. These data were used to estimate the time-averaged flow velocity (R 2   =  0.952), which represents the most common metric to assess fishway flows. The significant contribution of this work is the creation and application of hydrodynamic signatures generated by the spatial distribution of pressure fluctuations on the fish-shaped body. The signatures are based on the collection of the pressure fluctuations' probability distributions, and it is shown that they can be used to automatically classify distinct flow regions within the pools of three different vertical slot fishways. For the first time, field data from operational fishway measurements are sampled and classified using an artificial lateral line, providing a completely new source of bioinspired flow information.

  1. Separation of red blood cells in deep deterministic lateral displacement devices

    Science.gov (United States)

    Kabacaoglu, Gokberk; Biros, George

    2017-11-01

    Microfluidic cell separation techniques are of great interest since they help rapid medical diagnoses and tests. Deterministic lateral displacement (DLD) is one of them. A DLD device consists of arrays of pillars. Main flow and alignment of the pillars define two different directions. Size-based separation of rigid spherical particles is possible as they follow one of these directions depending on their sizes. However, the separation of non-spherical deformable particles such as red blood cells (RBCs) is more complicated than that due to their intricate dynamics. We study the separation of RBCs in DLD using an in-house integral equation solver. We systematically investigate the effects of the interior fluid viscosity and the membrane elasticity of an RBC on its behavior. These mechanical properties of a cell determine its deformability, which can be altered by several diseases. We particularly consider deep devices in which an RBC can show rich dynamics such as tank-treading and tumbling. It turns out that strong hydrodynamic lift force moves the tank-treading cells along the pillars and downward force leads the tumbling ones to move with the flow. Thereby, deformability-based separation of RBCs is possible.

  2. Method and device for measuring fluid flow

    International Nuclear Information System (INIS)

    Atherton, R.; Marinkovich, P.S.; Spadaro, P.R.; Stout, J.W.

    1976-01-01

    The invention is a fluid flow measuring device for determining the coolant flow at the entrance to a specific nuclear reactor fuel region. The device comprises a plurality of venturis having the upstream inlet and throat pressure of each respectively manifolded together to provide one static pressure signal for each region monitored. The device provides accurate flow measurement with low pressure losses and uniform entrance and discharge flow distribution. 1 claim, 7 figures

  3. One-dimensional breakdown voltage model of SOI RESURF lateral power device based on lateral linearly graded approximation

    International Nuclear Information System (INIS)

    Zhang Jun; Guo Yu-Feng; Xu Yue; Lin Hong; Yang Hui; Hong Yang; Yao Jia-Fei

    2015-01-01

    A novel one-dimensional (1D) analytical model is proposed for quantifying the breakdown voltage of a reduced surface field (RESURF) lateral power device fabricated on silicon on an insulator (SOI) substrate. We assume that the charges in the depletion region contribute to the lateral PN junctions along the diagonal of the area shared by the lateral and vertical depletion regions. Based on the assumption, the lateral PN junction behaves as a linearly graded junction, thus resulting in a reduced surface electric field and high breakdown voltage. Using the proposed model, the breakdown voltage as a function of device parameters is investigated and compared with the numerical simulation by the TCAD tools. The analytical results are shown to be in fair agreement with the numerical results. Finally, a new RESURF criterion is derived which offers a useful scheme to optimize the structure parameters. This simple 1D model provides a clear physical insight into the RESURF effect and a new explanation on the improvement in breakdown voltage in an SOI RESURF device. (paper)

  4. Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, K.; Kornecki, A.; Bax, J.; Mundt, Y.; Fenster, A. [Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Radiology, St. Joseph' s Health Care London, London, Ontario N6A 4V2 (Canada) and Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 5A5 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Radiology, St. Joseph' s Health Care London, London, Ontario N6A 4V2 (Canada) and Department of Diagnostic Radiology and Nuclear Medicine, University of Western Ontario, London, Ontario N6A 5A5 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada); Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada) and Department of Medical Imaging, University of Western Ontario, London, Ontario N6A 5A5 (Canada)

    2009-06-15

    Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample

  5. Behavior of instantaneous lateral velocity and flow pulsation in duct flow with cylindrical rod

    International Nuclear Information System (INIS)

    Lee, Chi Young; Shin, Chang Hwan; Park, Ju Yong; Oh, Dong Seok; Chun, Tae Hyun; In, Wang Kee

    2012-01-01

    Recently, KAERI (Korea Atomic Energy Research Institute) has examined and developed a dual cooled annular fuel. Dual cooled annular fuel allows the coolant to flow through the inner channel as well as the outer channel. Due to inner channel, the outer diameter of dual cooled annular fuel (15.9 mm) is larger than that of conventional cylindrical solid fuel (9.5 mm). Hence, dual cooled annular fuel assembly becomes a tight lattice fuel bundle configuration to maintain the same array size and guide tube locations as cylindrical solid fuel assembly. P/Ds (pitch between rods to rod diameter ratio) of dual cooled annular and cylindrical solid fuel assemblies are 1.08 and 1.35, respectively. This difference of P/D could change the behavior of turbulent flow in rod bundle. Our research group has investigated a turbulent flow parallel to the fuel rods using two kinds of simulated 3x3 rod bundles. To measure the turbulent rod bundle flow, PIV (Particle Image Velocimetry) and MIR (Matching Index of Refraction) techniques were used. In a simulated dual cooled annular fuel bundle (i.e., P/D=1.08), the quasi periodic oscillating flow motion in the lateral direction, called the flow pulsation, was observed, which significantly increased the lateral turbulence intensity at the rod gap center. The flow pulsation was visualized and measured clearly and successfully by PIV and MIR techniques. Such a flow motion may have influence on the fluid induced vibration, heat transfer, CHF (Critical Heat Flux), and flow mixing between subchannels in rod bundle flow. On the other hand, in a simulated cylindrical solid fuel bundle (i.e., P/D=1.35), the peak of turbulence intensity at the gap center was not measured due to an irregular motion of the lateral flow. This study implies that the behavior of lateral velocity in rod bundle flow is greatly influenced by the P/D (i.e., gap distance). In this work, the influence of gap distance on behavior of instantaneous lateral velocity and flow

  6. Recovery of viral RNA and infectious foot-and-mouth disease virus from positive lateral-flow devices.

    Science.gov (United States)

    Fowler, Veronica L; Bankowski, Bartlomiej M; Armson, Bryony; Di Nardo, Antonello; Valdazo-Gonzalez, Begoña; Reid, Scott M; Barnett, Paul V; Wadsworth, Jemma; Ferris, Nigel P; Mioulet, Valérie; King, Donald P

    2014-01-01

    Foot-and-mouth disease Virus (FMDV) is an economically important, highly contagious picornavirus that affects both wild and domesticated cloven hooved animals. In developing countries, the effective laboratory diagnosis of foot-and-mouth disease (FMD) is often hindered by inadequate sample preservation due to difficulties in the transportation and storage of clinical material. These factors can compromise the ability to detect and characterise FMD virus in countries where the disease is endemic. Furthermore, the high cost of sending infectious virus material and the biosecurity risk it presents emphasises the need for a thermo-stable, non-infectious mode of transporting diagnostic samples. This paper investigates the potential of using FMDV lateral-flow devices (LFDs) for dry transportation of clinical samples for subsequent nucleic acid amplification, sequencing and recovery of infectious virus by electroporation. FMDV positive samples (epithelial suspensions and cell culture isolates) representing four FMDV serotypes were applied to antigen LFDs: after which it was possible to recover viral RNA that could be detected using real-time RT-PCR. Using this nucleic acid, it was also possible to recover VP1 sequences and also successfully utilise protocols for amplification of complete FMD virus genomes. It was not possible to recover infectious FMDV directly from the LFDs, however following electroporation into BHK-21 cells and subsequent cell passage, infectious virus could be recovered. Therefore, these results support the use of the antigen LFD for the dry, non-hazardous transportation of samples from FMD endemic countries to international reference laboratories.

  7. Experimental Flow Characterization of a Flow Diverting Device

    Science.gov (United States)

    Sparrow, Eph; Chow, Ricky; Campbell, Gary; Divani, Afshin; Sheng, Jian

    2012-11-01

    Flow diverters, such as the Pipeline Embolization Device, are a new class of endovascular devices for the treatment of intracranial aneurysms. While clinical studies have demonstrated safety and efficacy, their impact on intra-aneurysmal flow is not confirmed experimentally. As such, optimization of the flow diversion behavior is not currently possible. A quasi-3D PIV technique was developed and applied in various glass models at Re = 275 and 550 to determine the changes to flow characteristics due to the deployment of a flow diverter across the aneurysm neck. Outcomes such as mean velocity, wall shear stress, and others metrics will be presented. Glass models with varying radii of curvature and aneurysm locations will be examined. Experiments were performed in a fully index-matched flow facility using ~10 μm diameter polystyrene particles doped with Rhodium 6G dye. The particles were illuminated with a 532nm laser sheet and observed with a CCD camera and a 592nm +/-43 nm bandpass filter. A quasi 3D flow field was reconstructed from multiple orthogonal planes (spaced 0.4mm apart) encompassing the entire glass model. Wall stresses were evaluated from the near-wall flow viscous stresses.

  8. Development of multiplex loop mediated isothermal amplification (m-LAMP) label-based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira

    International Nuclear Information System (INIS)

    Nurul Najian, A.B.; Engku Nur Syafirah, E.A.R.; Ismail, Nabilah; Mohamed, Maizan; Yean, Chan Yean

    2016-01-01

    In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10 −1 genomic equivalent ml −1 . An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device. - Highlights: • We develop multiplex LAMP label-based lateral flow dipstick biosensor for detection of pathogenic Leptospira. • We design primers for multiplex LAMP targeting the conserved LipL32 gene of pathogenic Leptospira and LAMP internal

  9. Development of multiplex loop mediated isothermal amplification (m-LAMP) label-based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira

    Energy Technology Data Exchange (ETDEWEB)

    Nurul Najian, A.B.; Engku Nur Syafirah, E.A.R.; Ismail, Nabilah [Department of Medical Microbiology & Parasitology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia); Mohamed, Maizan [Faculty of Veterinary Medicine, Universiti Malaysia Kelantan, City Campus, Pengkalan Chepa, Locked Bag 36, 16100 Kota Bharu, Kelantan (Malaysia); Yean, Chan Yean, E-mail: yeancyn@yahoo.com [Department of Medical Microbiology & Parasitology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia); Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2016-01-15

    In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10{sup −1} genomic equivalent ml{sup −1}. An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device. - Highlights: • We develop multiplex LAMP label-based lateral flow dipstick biosensor for detection of pathogenic Leptospira. • We design primers for multiplex LAMP targeting the conserved LipL32 gene of pathogenic Leptospira and LAMP

  10. Recovery of viral RNA and infectious foot-and-mouth disease virus from positive lateral-flow devices.

    Directory of Open Access Journals (Sweden)

    Veronica L Fowler

    Full Text Available Foot-and-mouth disease Virus (FMDV is an economically important, highly contagious picornavirus that affects both wild and domesticated cloven hooved animals. In developing countries, the effective laboratory diagnosis of foot-and-mouth disease (FMD is often hindered by inadequate sample preservation due to difficulties in the transportation and storage of clinical material. These factors can compromise the ability to detect and characterise FMD virus in countries where the disease is endemic. Furthermore, the high cost of sending infectious virus material and the biosecurity risk it presents emphasises the need for a thermo-stable, non-infectious mode of transporting diagnostic samples. This paper investigates the potential of using FMDV lateral-flow devices (LFDs for dry transportation of clinical samples for subsequent nucleic acid amplification, sequencing and recovery of infectious virus by electroporation. FMDV positive samples (epithelial suspensions and cell culture isolates representing four FMDV serotypes were applied to antigen LFDs: after which it was possible to recover viral RNA that could be detected using real-time RT-PCR. Using this nucleic acid, it was also possible to recover VP1 sequences and also successfully utilise protocols for amplification of complete FMD virus genomes. It was not possible to recover infectious FMDV directly from the LFDs, however following electroporation into BHK-21 cells and subsequent cell passage, infectious virus could be recovered. Therefore, these results support the use of the antigen LFD for the dry, non-hazardous transportation of samples from FMD endemic countries to international reference laboratories.

  11. High frequency lateral flow affinity assay using superparamagnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lago-Cachón, D., E-mail: dlagocachon@gmail.com [Dpto. de Física, Universidad de Oviedo, Edificio Departamental Este, Campus de Viesques, 33204 Gijón (Spain); Rivas, M., E-mail: rivas@uniovi.es [Dpto. de Física, Universidad de Oviedo, Edificio Departamental Este, Campus de Viesques, 33204 Gijón (Spain); Martínez-García, J.C., E-mail: jcmg@uniovi.es [Dpto. de Física, Universidad de Oviedo, Edificio Departamental Este, Campus de Viesques, 33204 Gijón (Spain); Oliveira-Rodríguez, M., E-mail: oliveiramyriam@uniovi.es [Dpto. de Química Física y Analítica, Universidad de Oviedo, C/Julián Clavería 8, 33006 Oviedo (Spain); Blanco-López, M.C., E-mail: cblanco@uniovi.es [Dpto. de Química Física y Analítica, Universidad de Oviedo, C/Julián Clavería 8, 33006 Oviedo (Spain); García, J.A., E-mail: joseagd@uniovi.es [Dpto. de Física, Universidad de Oviedo, Escuela de Marina, Campus de Viesques, 33204 Gijón (Spain)

    2017-02-01

    Lateral flow assay is one of the simplest and most extended techniques in medical diagnosis for point-of-care testing. Although it has been traditionally a positive/negative test, some work has been lately done to add quantitative abilities to lateral flow assay. One of the most successful strategies involves magnetic beads and magnetic sensors. Recently, a new technique of superparamagnetic nanoparticle detection has been reported, based on the increase of the impedance induced by the nanoparticles on a RF-current carrying copper conductor. This method requires no external magnetic field, which reduces the system complexity. In this work, nitrocellulose membranes have been installed on the sensor, and impedance measurements have been carried out during the sample diffusion by capillarity along the membrane. The impedance of the sensor changes because of the presence of magnetic nanoparticles. The results prove the potentiality of the method for point-of-care testing of biochemical substances and nanoparticle capillarity flow studies. - Highlights: • A method for quantification of Lateral Flow Assays is proposed. • MNP induce an increase of the impedance on a RF-current carrying copper sensor. • Magnetic nanoparticles (MNP) can be detected flowing over the sensing element.

  12. High frequency lateral flow affinity assay using superparamagnetic nanoparticles

    International Nuclear Information System (INIS)

    Lago-Cachón, D.; Rivas, M.; Martínez-García, J.C.; Oliveira-Rodríguez, M.; Blanco-López, M.C.; García, J.A.

    2017-01-01

    Lateral flow assay is one of the simplest and most extended techniques in medical diagnosis for point-of-care testing. Although it has been traditionally a positive/negative test, some work has been lately done to add quantitative abilities to lateral flow assay. One of the most successful strategies involves magnetic beads and magnetic sensors. Recently, a new technique of superparamagnetic nanoparticle detection has been reported, based on the increase of the impedance induced by the nanoparticles on a RF-current carrying copper conductor. This method requires no external magnetic field, which reduces the system complexity. In this work, nitrocellulose membranes have been installed on the sensor, and impedance measurements have been carried out during the sample diffusion by capillarity along the membrane. The impedance of the sensor changes because of the presence of magnetic nanoparticles. The results prove the potentiality of the method for point-of-care testing of biochemical substances and nanoparticle capillarity flow studies. - Highlights: • A method for quantification of Lateral Flow Assays is proposed. • MNP induce an increase of the impedance on a RF-current carrying copper sensor. • Magnetic nanoparticles (MNP) can be detected flowing over the sensing element.

  13. Nuclear fuel rack lateral support and preload device

    International Nuclear Information System (INIS)

    Knight, C.B.

    1979-01-01

    A lateral support device for a nuclear fuel rack is described. It is vertically positioned within a walled enclosure which provides a preload to maintain effective support. The device includes a scissors-jack which is mounted so that the drive screw is vertical. Upon rotation of the drive screw the jack expands horizontally, seating a load pad against a vertical wall. The load pad is affixed to the jack by an arm having a stack of spring washers which compress between the pad and the jack, thereby applying a selected preload

  14. Microfluidic devices and methods for integrated flow cytometry

    Science.gov (United States)

    Srivastava, Nimisha [Goleta, CA; Singh, Anup K [Danville, CA

    2011-08-16

    Microfluidic devices and methods for flow cytometry are described. In described examples, various sample handling and preparation steps may be carried out within a same microfluidic device as flow cytometry steps. A combination of imaging and flow cytometry is described. In some examples, spiral microchannels serve as incubation chambers. Examples of automated sample handling and flow cytometry are described.

  15. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Science.gov (United States)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  16. Continuous flow nitration in miniaturized devices

    Directory of Open Access Journals (Sweden)

    Amol A. Kulkarni

    2014-02-01

    Full Text Available This review highlights the state of the art in the field of continuous flow nitration with miniaturized devices. Although nitration has been one of the oldest and most important unit reactions, the advent of miniaturized devices has paved the way for new opportunities to reconsider the conventional approach for exothermic and selectivity sensitive nitration reactions. Four different approaches to flow nitration with microreactors are presented herein and discussed in view of their advantages, limitations and applicability of the information towards scale-up. Selected recent patents that disclose scale-up methodologies for continuous flow nitration are also briefly reviewed.

  17. New fundamental insights into capacitance modeling of laterally nonuniform MOS devices

    NARCIS (Netherlands)

    Aarts, A.C.T.; Hout, van der R.; Paasschens, J.C.J.; Scholten, A.J.; Willemsen, M.B.; Klaassen, D.B.M.

    2006-01-01

    In compact transistor modeling for circuit simulation, the capacitances of conventional MOS devices are commonly determined as the derivatives of terminal charges, which in their turn are obtained from the so-called Ward-Dutton charge partitioning scheme. For devices with a laterally nonuniform

  18. Development of multiplex loop mediated isothermal amplification (m-LAMP) label-based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira.

    Science.gov (United States)

    Nurul Najian, A B; Engku Nur Syafirah, E A R; Ismail, Nabilah; Mohamed, Maizan; Yean, Chan Yean

    2016-01-15

    In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10(-1) genomic equivalent ml(-1). An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Experimental effect of flow depth on ratio discharge in lateral intakes in river bend

    International Nuclear Information System (INIS)

    Masjedi, A; Foroushani, E P

    2012-01-01

    Open-channel dividing flow is characterized by the inflow and outflow discharges, the upstream and downstream water depths, and the recirculation flow in the branch channel. In general, diversion flow can be categorized as natural and artificial flow. Natural flow diversion usually occurs as braiding or cut-off in bend rivers, while artificial flow is man-made to divert flow by lateral intake channels for water supply. This study presents the results of a laboratory research into effect intake flow depth on ratio discharge in lateral intakes in 180 degree bend. Investigation on lateral intake and determination of intake flow depth is among the most important issues in lateral intake on ratio discharge with model intake flow depth were measured in a laboratory flume under clear-water. Experiments were conducted for various intake flow depths and with different discharges. It was found that by increasing the flow depth at 180 degree flume bend, ratio discharge increases.

  20. Research on Flow Field Perception Based on Artificial Lateral Line Sensor System

    Directory of Open Access Journals (Sweden)

    Guijie Liu

    2018-03-01

    Full Text Available In nature, the lateral line of fish is a peculiar and important organ for sensing the surrounding hydrodynamic environment, preying, escaping from predators and schooling. In this paper, by imitating the mechanism of fish lateral canal neuromasts, we developed an artificial lateral line system composed of micro-pressure sensors. Through hydrodynamic simulations, an optimized sensor structure was obtained and the pressure distribution models of the lateral surface were established in uniform flow and turbulent flow. Carrying out the corresponding underwater experiment, the validity of the numerical simulation method is verified by the comparison between the experimental data and the simulation results. In addition, a variety of effective research methods are proposed and validated for the flow velocity estimation and attitude perception in turbulent flow, respectively and the shape recognition of obstacles is realized by the neural network algorithm.

  1. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  2. Mapping of the lateral flow field in typical subchannels of a support grid with vanes

    International Nuclear Information System (INIS)

    McClusky, Heather L.; Holloway, Mary V.; Conover, Timothy A.; Beasley, Donald E.; Conner, Michael E.; Smith III, L. David

    2003-01-01

    Lateral flow fields in four subchannels of a model rod bundle fuel assembly are measured using particle image velocimetry. Vanes (split-vane pairs) are located on the downstream edge of the support grids in the rod bundle fuel assembly and generate swirling flow. Measurements are acquired at a nominal Reynolds number of 28,000 and for seven streamwise locations ranging from 1.4 to 17.0 hydraulic diameters downstream of the grid. The streamwise development of the lateral flow field is divided into two regions based on the lateral flow structure. In Region I, multiple vortices are present in the flow field and vortex interactions occur. Either a single circular vortex or a hairpin shaped flow structure is formed in Region II. Lateral kinetic energy, maximum lateral velocity, centroid of vorticity, radial profiles of azimuthal velocity, and angular momentum are employed as measures of the streamwise development of the lateral flow field. The particle image velocimetry measurements of the present study are compared with laser doppler velocimetry measurements taken for the identical support grids and flow condition. (author)

  3. Design of a microfluidic device with a non-traditional flow profile for on-chip damage to zebrafish sensory cells

    International Nuclear Information System (INIS)

    Kwon, Hyuck-Jin; Xu, Yuhao; Solovitz, Stephen A; Xue, Wei; Xu, Jie; Dimitrov, Alexander G; Coffin, Allison B

    2014-01-01

    Hearing loss affects millions of people worldwide and often results from the death of the sensory hair cells in the inner ear, and exposure to intense noise is one of the leading causes of hair cell damage. Recently, the zebrafish lateral line system has emerged as a powerful in vivo model for real-time studies of hair cell damage and protection. In this research, we designed a microfluidic device for inducing noise damage in hair cells of the zebrafish lateral line. As the first step, a 3D computational fluid dynamics (CFD) simulation was utilized to predict the flow pattern inside the device. An ideal flow pattern for our application should feature higher velocity near the sidewalls to over-stimulate the externally located hair cells, and minimum flow in the middle of the channel to protect the fish from high pressure on the head. Flow induced from ordinary channel geometry with a single inlet/outlet pair would not work because the parabolic velocity profile features the maximum flow speed in the middle of the channel. In order to achieve the desired flow pattern, sidewall inlet/outlet pairs were used to suppress the growth of boundary layers. CFD simulation was used to design parameters such as the dimensions of the microfluidic channel and the angle of the inlets and outlets. It was found that in the case of an empty 2.0 mm wide channel with the inlet/outlet pairs set to 45°, the flow velocity at the side of the channel would be 6.7 times faster than the velocity in the middle, approaching the optimal flow characteristics. In the case of a fish-loaded channel, simulation shows that a 1.0 mm wide channel with a 60° inlet/outlet angle creates the lowest pressure (0.3 Pa) on the fish head while maintaining a reasonably strong shear stress (1.9 Pa) on the lateral line hair cells. (technical note)

  4. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2018-06-05

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  5. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  6. A Lateral Flow Biosensor for the Detection of Single Nucleotide Polymorphisms.

    Science.gov (United States)

    Zeng, Lingwen; Xiao, Zhuo

    2017-01-01

    A lateral flow biosensor (LFB) is introduced for the detection of single nucleotide polymorphisms (SNPs). The assay is composed of two steps: circular strand displacement reaction and lateral flow biosensor detection. In step 1, the nucleotide at SNP site is recognized by T4 DNA ligase and the signal is amplified by strand displacement DNA polymerase, which can be accomplished at a constant temperature. In step 2, the reaction product of step 1 is detected by a lateral flow biosensor, which is a rapid and cost effective tool for nuclei acid detection. Comparing with conventional methods, it requires no complicated machines. It is suitable for the use of point of care diagnostics. Therefore, this simple, cost effective, robust, and promising LFB detection method of SNP has great potential for the detection of genetic diseases, personalized medicine, cancer related mutations, and drug-resistant mutations of infectious agents.

  7. Transient Characteristics of a Fluidic Device for Circulatory Jet Flow.

    Science.gov (United States)

    Phan, Hoa Thanh; Dinh, Thien Xuan; Bui, Phong Nhu; Dau, Van Thanh

    2018-03-13

    In this paper, we report on the design, simulation, and experimental analysis of a miniaturized device that can generate multiple circulated jet flows. The device is actuated by a lead zirconate titanate (PZT) diaphragm. The flows in the device were studied using three-dimensional transient numerical simulation with the programmable open source OpenFOAM and was comparable to the experimental result. Each flow is verified by two hotwires mounted at two positions inside each consisting chamber. The experiment confirmed that the flow was successfully created, and it demonstrated good agreement with the simulation. In addition, a prospective application of the device as an angular rate sensor is also demonstrated. The device is robust, is minimal in size, and can contribute to the development of multi-axis fluidic inertial sensors, fluidic amplifiers, gas mixing, coupling, and analysis.

  8. A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Directory of Open Access Journals (Sweden)

    Helene Andersson-Svahn

    2011-11-01

    Full Text Available Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (< 30 ng/mL determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings.

  9. Lateral Mixing Mechanisms in Vertical and Horizontal Interconnected Subchannel Two-Phase Flows

    International Nuclear Information System (INIS)

    Gencay, Sarman; Teyssedou, Alberto; Tye, Peter

    2002-01-01

    A lateral mixing model based on equal volume exchange between two laterally interconnected subchannels is presented. The following mixing mechanisms are taken into account in this model: (a) diversion cross flow, caused by the lateral pressure difference between adjacent subchannels; (b) turbulent void diffusion, which is governed by the lateral void fraction difference between the subchannels; (c) void drift, responsible for the tendency of the vapor phase to drift toward unobstructed regions; and (d) buoyancy drift, which takes into account the effect of gravity in horizontal flows. Experimental two-phase air-water data obtained using two test sections having different geometries and orientations are used to determine the diffusion coefficients required by the mixing model. Under the absence of diversion crossflow, i.e., negligible lateral pressure difference between the subchannels, it is observed that the diffusion coefficient increases with increasing average void fraction in the subchannels. Moreover, for vertical flows turbulent void diffusion seems to be considerably affected by the geometry of the subchannels. For horizontal flows under nonsymmetric inlet void fraction conditions, even though the interconnected subchannels have the same geometry, different turbulent void diffusion and void drift coefficients are required to satisfy the conditions of hydrodynamic equilibrium. In the present study this condition is achieved by introducing a new void drift coefficient expressed as a correction term applied to the turbulent void drift term

  10. Recharge and Lateral Groundwater Flow Boundary Conditions for the Saturated Zone Site-Scale Flow and Transport Model

    Energy Technology Data Exchange (ETDEWEB)

    B. Arnold; T. Corbet

    2001-12-18

    The purpose of the flow boundary conditions analysis is to provide specified-flux boundary conditions for the saturated zone (SZ) site-scale flow and transport model. This analysis is designed to use existing modeling and analysis results as the basis for estimated groundwater flow rates into the SZ site-scale model domain, both as recharge at the upper (water table) boundary and as underflow at the lateral boundaries. The objective is to provide consistency at the boundaries between the SZ site-scale flow model and other groundwater flow models. The scope of this analysis includes extraction of the volumetric groundwater flow rates simulated by the SZ regional-scale flow model to occur at the lateral boundaries of the SZ site-scale flow model and the internal qualification of the regional-scale model for use in this analysis model report (AMR). In addition, the scope includes compilation of information on the recharge boundary condition taken from three sources: (1) distributed recharge as taken from the SZ regional-scale flow model, (2) recharge below the area of the unsaturated zone (UZ) site-scale flow model, and (3) focused recharge along the Fortymile Wash channel.

  11. Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays.

    Science.gov (United States)

    Adhikari, Meena; Strych, Ulrich; Kim, Jinsu; Goux, Heather; Dhamane, Sagar; Poongavanam, Mohan-Vivekanandan; Hagström, Anna E V; Kourentzi, Katerina; Conrad, Jacinta C; Willson, Richard C

    2015-12-01

    We introduce the modification of bacteriophage particles with aptamers for use as bioanalytical reporters, and demonstrate the use of these particles in ultrasensitive lateral flow assays. M13 phage displaying an in vivo biotinylatable peptide (AviTag) genetically fused to the phage tail protein pIII were used as reporter particle scaffolds, with biotinylated aptamers attached via avidin-biotin linkages, and horseradish peroxidase (HRP) reporter enzymes covalently attached to the pVIII coat protein. These modified viral nanoparticles were used in immunochromatographic sandwich assays for the direct detection of IgE and of the penicillin-binding protein from Staphylococcus aureus (PBP2a). We also developed an additional lateral flow assay for IgE, in which the analyte is sandwiched between immobilized anti-IgE antibodies and aptamer-bearing reporter phage modified with HRP. The limit of detection of this LFA was 0.13 ng/mL IgE, ∼100 times lower than those of previously reported IgE assays.

  12. Imaging dipole flow sources using an artificial lateral-line system made of biomimetic hair flow sensors

    NARCIS (Netherlands)

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    2013-01-01

    In Nature, fish have the ability to localize prey, school, navigate, etc., using the lateral-line organ. Artificial hair flow sensors arranged in a linear array shape (inspired by the lateral-line system (LSS) in fish) have been applied to measure airflow patterns at the sensor positions. Here, we

  13. Experimental evidence of lateral flow in unsaturated homogeneous isotropic sloping soil due to rainfall

    Science.gov (United States)

    Sinai, G.; Dirksen, C.

    2006-12-01

    This paper describes laboratory experimental evidence for lateral flow in the top layer of unsaturated sloping soil due to rainfall. Water was applied uniformly on horizontal and V-shaped surfaces of fine sand, at rates about 100 times smaller than the saturated hydraulic conductivity. Flow regimes near the surface and in the soil bulk were studied by using dyes. Streamlines and streak lines and wetting fronts were visually studied and photographed through a vertical glass wall. Near wetting fronts the flow direction was always perpendicular to the fronts owing to dominant matrix potential gradients. Thus, during early wetting of dry sloping sand, the flow direction is directed upslope. Far above a wetting front the flow was vertical due to the dominance of gravity. Downslope flow was observed during decreasing rainfall and dry periods. The lateral movement was largest near the soil surface and decayed with soil depth. Unstable downslope lateral flow close to the soil surface was attributed to non-Darcian flow due to variable temporal and spatial raindrop distributions. The experiments verify the theory that predicts unsaturated downslope lateral flow in sloping soil due to rainfall dynamics only, without apparent soil texture difference or anisotropy. This phenomenon could have significant implications for hillside hydrology, desert agriculture, irrigation management, etc., as well as for the basic mechanisms of surface runoff and erosion.

  14. Multiplexed lateral flow biosensors: Technological advances for radically improving point-of-care diagnoses.

    Science.gov (United States)

    Li, Jia; Macdonald, Joanne

    2016-09-15

    Lateral flow biosensors are a leading technology in point-of-care diagnostics due to their simplicity, rapidness and low cost. Their primacy in this arena continues through technological breakthroughs such as multiplexing: the detection of more than one biomarker in a single assay. Multiplexing capacity is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases and reducing diagnostic cost. Here we review, for the first time, the various types and strategies employed for creating multiplexed lateral flow biosensors. These are classified into four main categories in terms of specific application or multiplexing level, namely linear, parameter, spatial and conceptual. We describe the practical applications and implications for each approach and compare their advantages and disadvantages. Importantly, multiplexing is still subject to limitations of the traditional lateral flow biosensor, such as sensitivity and specificity. However, by pushing the limitations of the traditional medium into the multiplex arena, several technological breakthroughs are emerging with novel solutions that further expand the utility of lateral flow biosensing for point-of-care applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Flow Control Device Evaluation for an Internal Flow with an Adverse Pressure Gradient

    Science.gov (United States)

    Jenkins, Luther N.; Gorton, Susan Althoff; Anders, Scott G.

    2002-01-01

    The effectiveness of several active and passive devices to control flow in an adverse pressure gradient with secondary flows present was evaluated in the 15 Inch Low Speed Tunnel at NASA Langley Research Center. In this study, passive micro vortex generators, micro bumps, and piezoelectric synthetic jets were evaluated for their flow control characteristics using surface static pressures, flow visualization, and 3D Stereo Digital Particle Image Velocimetry. Data also were acquired for synthetic jet actuators in a zero flow environment. It was found that the micro vortex generator is very effective in controlling the flow environment for an adverse pressure gradient, even in the presence of secondary vortical flow. The mechanism by which the control is effected is a re-energization of the boundary layer through flow mixing. The piezoelectric synthetic jet actuators must have sufficient velocity output to produce strong longitudinal vortices if they are to be effective for flow control. The output of these devices in a laboratory or zero flow environment will be different than the output in a flow environment. In this investigation, the output was higher in the flow environment, but the stroke cycle in the flow did not indicate a positive inflow into the synthetic jet.

  16. Properties study of LiNbO3 lateral field excited device working on thickness extension mode

    International Nuclear Information System (INIS)

    Zhi-Tian, Zhang; Ting-Feng, Ma; Chao, Zhang; Wen-Yan, Wang; Yan, Liu; Guan-Ping, Feng

    2010-01-01

    This paper investigates the properties of thickness extension mode excited by lateral electric field on LiNbO 3 by using the extended Christoffel–Bechmann method. It finds that the lateral field excitation coupling factor for a-mode (quasi-extensional mode) reaches its maximum value of 28% on X-cut LiNbO 3 . The characteristics of a lateral field excitation device made of X-cut LiNbO 3 have been investigated and the lateral field excitation device is used for the design of a high frequency ultrasonic transducer. The time and frequency domain pulse/echo response of the LiNbO 3 lateral field excitation ultrasonic transducer is analysed with the modified Krimholtz–Leedom–Matthae model and tested using traditional pulse/echo method. A LiNbO 3 lateral field excitation ultrasonic transducer with the centre frequency of 33.44 MHz and the −6 dB bandwidth of 33.8% is acquired, which is in good agreement with the results of the Krimholtz–Leedom–Matthae model. Further analysis suggests that the LiNbO 3 lateral field excitation device has great potential in the design of broadband high frequency ultrasonic transducers. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  17. Lateral Flow Field Behavior Downstream of Mixing Vanes In a Simulated Nuclear Fuel Rod Bundle

    International Nuclear Information System (INIS)

    Conner, Michael E.; Smith, L. David III; Holloway, Mary V.; Beasley, Donald E.

    2004-01-01

    To assess the fuel assembly performance of PWR nuclear fuel assemblies, average subchannel flow values are used in design analyses. However, for this highly complex flow, it is known that local conditions around fuel rods vary dependent upon the location of the fuel rod in the fuel assembly and upon the support grid design that maintains the fuel rod pitch. To investigate the local flow in a simulated nuclear fuel rod bundle, a testing technique has been employed to measure the lateral flow field in a 5 x 5 rod bundle. Particle Image Velocimetry was used to measure the lateral flow field downstream of a support grid with mixing vanes for four unique subchannels in the 5 x 5 bundle. The dominant lateral flow structures for each subchannel are compared in this paper including the decay of these flow structures. (authors)

  18. Analytical Tools to Improve Optimization Procedures for Lateral Flow Assays

    Directory of Open Access Journals (Sweden)

    Helen V. Hsieh

    2017-05-01

    Full Text Available Immunochromatographic or lateral flow assays (LFAs are inexpensive, easy to use, point-of-care medical diagnostic tests that are found in arenas ranging from a doctor’s office in Manhattan to a rural medical clinic in low resource settings. The simplicity in the LFA itself belies the complex task of optimization required to make the test sensitive, rapid and easy to use. Currently, the manufacturers develop LFAs by empirical optimization of material components (e.g., analytical membranes, conjugate pads and sample pads, biological reagents (e.g., antibodies, blocking reagents and buffers and the design of delivery geometry. In this paper, we will review conventional optimization and then focus on the latter and outline analytical tools, such as dynamic light scattering and optical biosensors, as well as methods, such as microfluidic flow design and mechanistic models. We are applying these tools to find non-obvious optima of lateral flow assays for improved sensitivity, specificity and manufacturing robustness.

  19. Analytical models of lateral power devices with arbitrary vertical doping profiles in the drift region

    International Nuclear Information System (INIS)

    Hua Ting-Ting; Guo Yu-Feng; Yu Ying; Jian Tong; Yao Jia-Fei; Sheu Gene

    2013-01-01

    By solving the 2D Poisson's equation, analytical models are proposed to calculate the surface potential and electric field distributions of lateral power devices with arbitrary vertical doping profiles. The vertical and the lateral breakdown voltages are formulized to quantify the breakdown characteristic in completely-depleted and partially-depleted cases. A new reduced surface field (RESURF) criterion which can be used in various drift doping profiles is further derived for obtaining the optimal trade-off between the breakdown voltage and the on-resistance. Based on these models and the numerical simulation, the electric field modulation mechanism and the breakdown characteristics of lateral power devices are investigated in detail for the uniform, linear, Gaussian, and some discrete doping profiles along the vertical direction in the drift region. Then, the mentioned vertical doping profiles of these devices with the same geometric parameters are optimized, and the results show that the optimal breakdown voltages and the effective drift doping concentrations of these devices are identical, which are equal to those of the uniform-doped device, respectively. The analytical results of these proposed models are in good agreement with the numerical results and the previous experimental results, confirming the validity of the models presented here. (interdisciplinary physics and related areas of science and technology)

  20. Analytical models of lateral power devices with arbitrary vertical doping profiles in the drift region

    Science.gov (United States)

    Hua, Ting-Ting; Guo, Yu-Feng; Yu, Ying; Gene, Sheu; Jian, Tong; Yao, Jia-Fei

    2013-05-01

    By solving the 2D Poisson's equation, analytical models are proposed to calculate the surface potential and electric field distributions of lateral power devices with arbitrary vertical doping profiles. The vertical and the lateral breakdown voltages are formulized to quantify the breakdown characteristic in completely-depleted and partially-depleted cases. A new reduced surface field (RESURF) criterion which can be used in various drift doping profiles is further derived for obtaining the optimal trade-off between the breakdown voltage and the on-resistance. Based on these models and the numerical simulation, the electric field modulation mechanism and the breakdown characteristics of lateral power devices are investigated in detail for the uniform, linear, Gaussian, and some discrete doping profiles along the vertical direction in the drift region. Then, the mentioned vertical doping profiles of these devices with the same geometric parameters are optimized, and the results show that the optimal breakdown voltages and the effective drift doping concentrations of these devices are identical, which are equal to those of the uniform-doped device, respectively. The analytical results of these proposed models are in good agreement with the numerical results and the previous experimental results, confirming the validity of the models presented here.

  1. Coping with flow: behavior, neurophysiology and modeling of the fish lateral line system.

    Science.gov (United States)

    Mogdans, Joachim; Bleckmann, Horst

    2012-12-01

    With the mechanosensory lateral line fish perceive water motions relative to their body surface and local pressure gradients. The lateral line plays an important role in many fish behaviors including the detection and localization of dipole sources and the tracking of prey fish. The sensory units of the lateral line are the neuromasts which are distributed across the surface of the animal. Water motions are received and transduced into neuronal signals by the neuromasts. These signals are conveyed by afferent nerve fibers to the fish brain and processed by lateral line neurons in parts of the brainstem, cerebellum, midbrain, and forebrain. In the cerebellum, midbrain, and forebrain, lateral line information is integrated with sensory information from other modalities. The present review introduces the peripheral morphology of the lateral line, and describes our understanding of lateral line physiology and behavior. It focuses on recent studies that have investigated: how fish behave in unsteady flow; what kind of sensory information is provided by flow; and how fish use and process this information. Finally, it reports new theoretical and biomimetic approaches to understand lateral line function.

  2. Wave propagation and power flow in an acoustic metamaterial plate with lateral local resonance attachment

    Science.gov (United States)

    Wang, Ting; Sheng, Meiping; Ding, Xiaodong; Yan, Xiaowei

    2018-03-01

    This paper presents analysis on wave propagation and power flow in an acoustic metamaterial plate with lateral local resonance. The metamaterial is designed to have lateral local resonance systems attached to a homogeneous plate. Relevant theoretical analysis, numerical modelling and application prospect are presented. Results show that the metamaterial has two complete band gaps for flexural wave absorption and vibration attenuation. Damping can smooth and lower the metamaterial’s frequency responses in high frequency ranges at the expense of the band gap effect, and as an important factor to calculate the power flow is thoroughly investigated. Moreover, the effective mass density becomes negative and unbounded at specific frequencies. Simultaneously, power flow within band gaps are dramatically blocked from the power flow contour and power flow maps. Results from finite element modelling and power flow analysis reveal the working mechanism of the flexural wave attenuation and power flow blocked within the band gaps, where part of the flexural vibration is absorbed by the vertical resonator and the rest is transformed through four-link-mechanisms to the lateral resonators that oscillate and generate inertial forces indirectly to counterbalance the shear forces induced by the vibrational plate. The power flow is stored in the vertical and lateral local resonance, as well as in the connected plate.

  3. The eye-tracking computer device for communication in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Spataro, R; Ciriacono, M; Manno, C; La Bella, V

    2014-07-01

    To explore the effectiveness of communication and the variables affecting the eye-tracking computer system (ETCS) utilization in patients with late-stage amyotrophic lateral sclerosis (ALS). We performed a telephone survey on 30 patients with advanced non-demented ALS that were provisioned an ECTS device. Median age at interview was 55 years (IQR = 48-62), with a relatively high education (13 years, IQR = 8-13). A one-off interview was made and answers were later provided with the help of the caregiver. The interview included items about demographic and clinical variables affecting the daily ETCS utilization. The median time of ETCS device possession was 15 months (IQR = 9-20). The actual daily utilization was 300 min (IQR = 100-720), mainly for the communication with relatives/caregiver, internet surfing, e-mailing, and social networking. 23.3% of patients with ALS (n = 7) had a low daily ETCS utilization; most reported causes were eye-gaze tiredness and oculomotor dysfunction. Eye-tracking computer system is a valuable device for AAC in patients with ALS, and it can be operated with a good performance. The development of oculomotor impairment may limit its functional use. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Simulation and validation of concentrated subsurface lateral flow paths in an agricultural landscape

    Science.gov (United States)

    Zhu, Q.; Lin, H. S.

    2009-08-01

    The importance of soil water flow paths to the transport of nutrients and contaminants has long been recognized. However, effective means of detecting concentrated subsurface flow paths in a large landscape are still lacking. The flow direction and accumulation algorithm based on single-direction flow algorithm (D8) in GIS hydrologic modeling is a cost-effective way to simulate potential concentrated flow paths over a large area once relevant data are collected. This study tested the D8 algorithm for simulating concentrated lateral flow paths at three interfaces in soil profiles in a 19.5-ha agricultural landscape in central Pennsylvania, USA. These interfaces were (1) the interface between surface plowed layers of Ap1 and Ap2 horizons, (2) the interface with subsoil water-restricting clay layer where clay content increased to over 40%, and (3) the soil-bedrock interface. The simulated flow paths were validated through soil hydrologic monitoring, geophysical surveys, and observable soil morphological features. The results confirmed that concentrated subsurface lateral flow occurred at the interfaces with the clay layer and the underlying bedrock. At these two interfaces, the soils on the simulated flow paths were closer to saturation and showed more temporally unstable moisture dynamics than those off the simulated flow paths. Apparent electrical conductivity in the soil on the simulated flow paths was elevated and temporally unstable as compared to those outside the simulated paths. The soil cores collected from the simulated flow paths showed significantly higher Mn content at these interfaces than those away from the simulated paths. These results suggest that (1) the D8 algorithm is useful in simulating possible concentrated subsurface lateral flow paths if used with appropriate threshold value of contributing area and sufficiently detailed digital elevation model (DEM); (2) repeated electromagnetic surveys can reflect the temporal change of soil water storage

  5. Compressible Flow Phenomena at Inception of Lateral Density Currents Fed by Collapsing Gas-Particle Mixtures

    Science.gov (United States)

    Valentine, Greg A.; Sweeney, Matthew R.

    2018-02-01

    Many geological flows are sourced by falling gas-particle mixtures, such as during collapse of lava domes, and impulsive eruptive jets, and sustained columns, and rock falls. The transition from vertical to lateral flow is complex due to the range of coupling between particles of different sizes and densities and the carrier gas, and due to the potential for compressible flow phenomena. We use multiphase modeling to explore these dynamics. In mixtures with small particles, and with subsonic speeds, particles follow the gas such that outgoing lateral flows have similar particle concentration and speed as the vertical flows. Large particles concentrate immediately upon impact and move laterally away as granular flows overridden by a high-speed jet of expelled gas. When a falling flow is supersonic, a bow shock develops above the impact zone, and this produces a zone of high pressure from which lateral flows emerge as overpressured wall jets. The jets form complex structures as the mixtures expand and accelerate and then recompress through a recompression zone that mimics a Mach disk shock in ideal gas jets. In mixtures with moderate to high ratios of fine to coarse particles, the latter tend to follow fine particles through the expansion-recompression flow fields because of particle-particle drag. Expansion within the flow fields can lead to locally reduced gas pressure that could enhance substrate erosion in natural flows. The recompression zones form at distances, and have peak pressures, that are roughly proportional to the Mach numbers of impacting flows.

  6. New Fpg probe chemistry for direct detection of recombinase polymerase amplification on lateral flow strips.

    Science.gov (United States)

    Powell, Michael L; Bowler, Frank R; Martinez, Aurore J; Greenwood, Catherine J; Armes, Niall; Piepenburg, Olaf

    2018-02-15

    Rapid, cost-effective and sensitive detection of nucleic acids has the ability to improve upon current practices employed for pathogen detection in diagnosis of infectious disease and food testing. Furthermore, if assay complexity can be reduced, nucleic acid amplification tests could be deployed in resource-limited and home use scenarios. In this study, we developed a novel Fpg (Formamidopyrimidine DNA glycosylase) probe chemistry, which allows lateral flow detection of amplification in undiluted recombinase polymerase amplification (RPA) reactions. The prototype nucleic acid lateral flow chemistry was applied to a human genomic target (rs1207445), Campylobacter jejuni 16S rDNA and two genetic markers of the important food pathogen E. coli O157:H7. All four assays have an analytical sensitivity between 10 and 100 copies DNA per amplification. Furthermore, the assay is performed with fewer hands-on steps than using the current RPA Nfo lateral flow method as dilution of amplicon is not required for lateral flow analysis. Due to the simplicity of the workflow, we believe that the lateral flow chemistry for direct detection could be readily adapted to a cost-effective single-use consumable, ideal for use in non-laboratory settings. Copyright © 2017. Published by Elsevier Inc.

  7. Effect Of Steel Flow Control Devices On Flow And Temperature Field In The Tundish Of Continuous Casting Machine

    Directory of Open Access Journals (Sweden)

    Sowa L.

    2015-06-01

    Full Text Available The mathematical model and numerical simulations of the liquid steel flow in a tundish are presented in this paper. The problem was treated as a complex and solved by the finite element method. One takes into consideration in the mathematical model the changes of thermophysical parameters depending on the temperature. The single-strand tundish is used to casting slabs. The internal work space of the tundish was modified by flow control devices. The first device was a pour pad situated in the pouring tundish zone. The second device was a dam. The third device was a baffle with three holes. The dam and baffle were placed in the tundish at different positions depending on the variant. The main purpose of using these was to put barriers in the steel flow path as well as give directional metal flow upwards which facilitated inclusion floatation. The interaction of flow control devices on hydrodynamic conditions was received from numerical simulations. As a result of the computations carried out, the liquid steel flow and steel temperature fields were obtained. The influences of the tundish modifications on the velocity fields in liquid phase of the steel were estimated, because these have essential an influence on high-quality of a continuous steel cast slab.

  8. Communication during pediatric asthma visits and child asthma medication device technique 1 month later.

    Science.gov (United States)

    Sleath, Betsy; Carpenter, Delesha M; Ayala, Guadalupe X; Williams, Dennis; Davis, Stephanie; Tudor, Gail; Yeatts, Karin; Gillette, Chris

    2012-11-01

    This study investigated how provider demonstration of and assessment of child use of asthma medication devices and certain aspects of provider-patient communication during medical visits is associated with device technique 1 month later. Two hundred and ninety-six children aged 8-16 years with persistent asthma and their caregivers were recruited at five North Carolina pediatric practices. All of the medical visits were audio-tape recorded. Children were interviewed 1 month later and their device technique was observed and rated. If the provider asked the child to demonstrate metered dose inhaler technique during the medical visit, then the child was significantly more likely to perform a greater percentage of inhaler steps correctly 1 month later. Children with higher asthma management self-efficacy scores were significantly more likely to perform a greater percentage of diskus steps correctly. Additionally, children were significantly more likely to perform a greater percentage of diskus steps correctly if the provider discussed a written action plan during the visit. Children were significantly more likely to perform a greater percentage of turbuhaler steps correctly if they asked more medication questions. Providers should ask children to demonstrate their inhaler technique during medical visits so that they can educate children about proper technique and improve child asthma management self-efficacy. Providers should encourage children to ask questions about asthma medication devices during visits and they should discuss asthma action plans with families.

  9. Quantum dots for future nanophotonic devices : lateral ordering, position, and number control

    NARCIS (Netherlands)

    Nötzel, R.

    2010-01-01

    After the general aspects of InAs/InP (100) quantum dots (QDs) regarding the formation of QDs versus quantum dashes, wavelength tuning from telecom to mid-infrared region, and device applications, we discuss our recent progress on the lateral ordering, position, and number control of QDs.

  10. Device for measuring the temperature of flowing hot gases

    Energy Technology Data Exchange (ETDEWEB)

    Reed, R D

    1977-05-12

    The invention pertains to a device to measure the temperature of a hot gas flowing through a closed tube. The device will have a simple and inexpensive design and avoid heat losses due to heat radiation near the thermal sensor.

  11. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  12. Device for accurately measuring mass flow of gases

    Science.gov (United States)

    Hylton, James O.; Remenyik, Carl J.

    1994-01-01

    A device for measuring mass flow of gases which utilizes a substantially buoyant pressure vessel suspended within a fluid/liquid in an enclosure. The pressure vessel is connected to a weighing device for continuously determining weight change of the vessel as a function of the amount of gas within the pressure vessel. In the preferred embodiment, this pressure vessel is formed from inner and outer right circular cylindrical hulls, with a volume between the hulls being vented to the atmosphere external the enclosure. The fluid/liquid, normally in the form of water typically with an added detergent, is contained within an enclosure with the fluid/liquid being at a level such that the pressure vessel is suspended beneath this level but above a bottom of the enclosure. The buoyant pressure vessel can be interconnected with selected valves to an auxiliary pressure vessel so that initial flow can be established to or from the auxiliary pressure vessel prior to flow to or from the buoyant pressure vessel.

  13. RSTensorFlow: GPU Enabled TensorFlow for Deep Learning on Commodity Android Devices.

    Science.gov (United States)

    Alzantot, Moustafa; Wang, Yingnan; Ren, Zhengshuang; Srivastava, Mani B

    2017-06-01

    Mobile devices have become an essential part of our daily lives. By virtue of both their increasing computing power and the recent progress made in AI, mobile devices evolved to act as intelligent assistants in many tasks rather than a mere way of making phone calls. However, popular and commonly used tools and frameworks for machine intelligence are still lacking the ability to make proper use of the available heterogeneous computing resources on mobile devices. In this paper, we study the benefits of utilizing the heterogeneous (CPU and GPU) computing resources available on commodity android devices while running deep learning models. We leveraged the heterogeneous computing framework RenderScript to accelerate the execution of deep learning models on commodity Android devices. Our system is implemented as an extension to the popular open-source framework TensorFlow. By integrating our acceleration framework tightly into TensorFlow, machine learning engineers can now easily make benefit of the heterogeneous computing resources on mobile devices without the need of any extra tools. We evaluate our system on different android phones models to study the trade-offs of running different neural network operations on the GPU. We also compare the performance of running different models architectures such as convolutional and recurrent neural networks on CPU only vs using heterogeneous computing resources. Our result shows that although GPUs on the phones are capable of offering substantial performance gain in matrix multiplication on mobile devices. Therefore, models that involve multiplication of large matrices can run much faster (approx. 3 times faster in our experiments) due to GPU support.

  14. Gravity insensitive inventory control device for a two-phase flow system

    International Nuclear Information System (INIS)

    Bland, T.J.

    1987-01-01

    A liquid inventory control device is described for a flow system where the liquid changes phase to a vapor and back and a pitot pump separates vapor from liquid and pumps the liquid to a component of the flow system comprising: a liquid storage device for storing liquid under pressure, a tube positioned within the pitot pump and in open communication with the liquid storage device, and the tube having an opening positioned within the pitot pump at a location to establish a desired liquid level in the pitot pump and at which level the pressure at the pitot tube inlet will equal the liquid pressure at the liquid storage device

  15. Simple system for isothermal DNA amplification coupled to lateral flow detection.

    Directory of Open Access Journals (Sweden)

    Kristina Roskos

    Full Text Available Infectious disease diagnosis in point-of-care settings can be greatly improved through integrated, automated nucleic acid testing devices. We have developed an early prototype for a low-cost system which executes isothermal DNA amplification coupled to nucleic acid lateral flow (NALF detection in a mesofluidic cartridge attached to a portable instrument. Fluid handling inside the cartridge is facilitated through one-way passive valves, flexible pouches, and electrolysis-driven pumps, which promotes a compact and inexpensive instrument design. The closed-system disposable prevents workspace amplicon contamination. The cartridge design is based on standard scalable manufacturing techniques such as injection molding. Nucleic acid amplification occurs in a two-layer pouch that enables efficient heat transfer. We have demonstrated as proof of principle the amplification and detection of Mycobacterium tuberculosis (M.tb genomic DNA in the cartridge, using either Loop Mediated Amplification (LAMP or the Exponential Amplification Reaction (EXPAR, both coupled to NALF detection. We envision that a refined version of this cartridge, including upstream sample preparation coupled to amplification and detection, will enable fully-automated sample-in to answer-out infectious disease diagnosis in primary care settings of low-resource countries with high disease burden.

  16. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  17. Fluorescent carbon nanoparticle-based lateral flow biosensor for ultrasensitive detection of DNA.

    Science.gov (United States)

    Takalkar, Sunitha; Baryeh, Kwaku; Liu, Guodong

    2017-12-15

    We report a fluorescent carbon nanoparticle (FCN)-based lateral flow biosensor for ultrasensitive detection of DNA. Fluorescent carbon nanoparticle with a diameter of around 15nm was used as a tag to label a detection DNA probe, which was complementary with the part of target DNA. A capture DNA probe was immobilized on the test zone of the lateral flow biosensor. Sandwich-type hybridization reactions among the FCN-labeled DNA probe, target DNA and capture DNA probe were performed on the lateral flow biosensor. In the presence of target DNA, FCNs were captured on the test zone of the biosensor and the fluorescent intensity of the captured FCNs was measured with a portable fluorescent reader. After systematic optimizations of experimental parameters (the components of running buffers, the concentration of detection DNA probe used in the preparation of FCN-DNA conjugates, the amount of FCN-DNA dispensed on the conjugate pad and the dispensing cycles of the capture DNA probes on the test-zone), the biosensor could detect a minimum concentration of 0.4 fM DNA. This study provides a rapid and low-cost approach for DNA detection with high sensitivity, showing great promise for clinical application and biomedical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays

    Directory of Open Access Journals (Sweden)

    Linda G. Lee

    2013-10-01

    Full Text Available We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.

  19. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.

    Science.gov (United States)

    König, Kai; Stock, Ellen L; Jarvis, Melanie

    2013-01-01

    Excessive ambient noise levels have been identified as a potential risk factor for adverse outcome in very preterm infants. Noise level measurements for continuous positive airway pressure (CPAP) devices demonstrated that these constantly exceed current recommendations. The use of high-flow nasal cannula (HFNC) as an alternative non-invasive ventilation modality has become more popular in recent years in neonatal care. To study noise levels of two HFNC devices commonly used in newborns. As a comparison, noise levels of a continuous flow CPAP device were also studied. In-vitro study. The noise levels of two contemporary HFNC devices (Fisher & Paykel NHF™ and Vapotherm Precision Flow®) and one CPAP device (Dräger Babylog® 8000 plus) were measured in the oral cavity of a newborn manikin in an incubator in a quiet environment. HFNC flows of 4-8 l/min and CPAP pressures of 4-8 cm H2O were applied. The CPAP flow was set at 8 l/min as per unit practice. Vapotherm HFNC generated the highest noise levels, measuring 81.2-91.4 dB(A) with increasing flow. Fisher & Paykel HFNC noise levels were between 78.8 and 81.2 dB(A). The CPAP device generated the lowest noise levels between 73.9 and 77.4 dB(A). Both HFNC devices generated higher noise levels than the CPAP device. All noise levels were far above current recommendations of the American Academy of Pediatrics. In light of the long duration of non-invasive respiratory support of very preterm infants, less noisy devices are required to prevent the potentially adverse effects of continuing excessive noise exposure in the neonatal intensive care unit. Copyright © 2013 S. Karger AG, Basel.

  20. An evaluation of the hydrologic relevance of lateral flow in snow at hillslope and catchment scales

    Science.gov (United States)

    David Eiriksson; Michael Whitson; Charles H. Luce; Hans Peter Marshall; John Bradford; Shawn G. Benner; Thomas Black; Hank Hetrick; James P. McNamara

    2013-01-01

    Lateral downslope flow in snow during snowmelt and rain-on-snow (ROS) events is a well-known phenomenon, yet its relevance to water redistribution at hillslope and catchment scales is not well understood. We used dye tracers, geophysical methods, and hydrometric measurements to describe the snow properties that promote lateral flow, assess the relative velocities of...

  1. Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices

    Directory of Open Access Journals (Sweden)

    Mukhopadhyay Subhadeep

    2011-01-01

    Full Text Available Abstract Polymethylmethacrylate (PMMA microfluidic devices have been fabricated using a hot embossing technique to incorporate micro-pillar features on the bottom wall of the device which when combined with either a plasma treatment or the coating of a diamond-like carbon (DLC film presents a range of surface modification profiles. Experimental results presented in detail the surface modifications in the form of distinct changes in the static water contact angle across a range from 44.3 to 81.2 when compared to pristine PMMA surfaces. Additionally, capillary flow of water (dyed to aid visualization through the microfluidic devices was recorded and analyzed to provide comparison data between filling time of a microfluidic chamber and surface modification characteristics, including the effects of surface energy and surface roughness on the microfluidic flow. We have experimentally demonstrated that fluid flow and thus filling time for the microfluidic device was significantly faster for the device with surface modifications that resulted in a lower static contact angle, and also that the incorporation of micro-pillars into a fluidic device increases the filling time when compared to comparative devices.

  2. Devices and methods of operation thereof for providing stable flow for centrifugal compressors

    Science.gov (United States)

    Skoch, Gary J. (Inventor); Stevens, Mark A. (Inventor); Jett, Thomas A. (Inventor)

    2008-01-01

    Centrifugal compressor flow stabilizing devices and methods of operation thereof are disclosed that act upon the flow field discharging from the impeller of a centrifugal compressor and modify the flow field ahead of the diffuser vanes such that flow conditions contributing to rotating stall and surge are reduced or even eliminated. In some embodiments, shaped rods and methods of operation thereof are disclosed, whereas in other embodiments reverse-tangent air injection devices and methods are disclosed.

  3. Image-based modelling of lateral magma flow: the Basement Sill, Antarctica.

    Science.gov (United States)

    Petford, Nick; Mirhadizadeh, Seyed

    2017-05-01

    The McMurdo Dry Valleys magmatic system, Antarctica, provides a world-class example of pervasive lateral magma flow on a continental scale. The lowermost intrusion (Basement Sill) offers detailed sections through the now frozen particle microstructure of a congested magma slurry. We simulated the flow regime in two and three dimensions using numerical models built on a finite-element mesh derived from field data. The model captures the flow behaviour of the Basement Sill magma over a viscosity range of 1-10 4  Pa s where the higher end (greater than or equal to 10 2  Pa s) corresponds to a magmatic slurry with crystal fractions varying between 30 and 70%. A novel feature of the model is the discovery of transient, low viscosity (less than or equal to 50 Pa s) high Reynolds number eddies formed along undulating contacts at the floor and roof of the intrusion. Numerical tracing of particle orbits implies crystals trapped in eddies segregate according to their mass density. Recovered shear strain rates (10 -3 -10 -5  s -1 ) at viscosities equating to high particle concentrations (around more than 40%) in the Sill interior point to shear-thinning as an explanation for some types of magmatic layering there. Model transport rates for the Sill magmas imply a maximum emplacement time of ca 10 5 years, consistent with geochemical evidence for long-range lateral flow. It is a theoretically possibility that fast-flowing magma on a continental scale will be susceptible to planetary-scale rotational forces.

  4. Instability of shallow open channel flow with lateral velocity gradients

    Energy Technology Data Exchange (ETDEWEB)

    Lima, A C; Izumi, N, E-mail: adriano@eng.hokudai.ac.jp, E-mail: nizumi@eng.hokudai.ac.jp [River and Watershed Engineering Laboratory, Hokkaido University, Sapporo, 060-8628 (Japan)

    2011-12-22

    The turbulent flow in a wide rectangular open channel partially covered with vegetation is studied using linear stability analysis. In the base state normal flow condition, the water depth is constant and the transverse velocity vanishes, while there is a lateral gradient in the streamwise velocity with an inflexion point at the boundary between the vegetated zone and the main channel. The Reynolds stress is expressed by introducing the eddy viscosity, which is obtained from assuming a logarithmic distribution of the velocity near the bed. Perturbation expansions are introduced to the streamwise and transverse velocities, as well as to the water depth. The system of governing equations was solved in order to determine the maximum growth rate of the perturbations as a function of parameters which describe physical characteristics of the channel and the flow.

  5. Distributed flow estimation and closed-loop control of an underwater vehicle with a multi-modal artificial lateral line.

    Science.gov (United States)

    DeVries, Levi; Lagor, Francis D; Lei, Hong; Tan, Xiaobo; Paley, Derek A

    2015-03-25

    Bio-inspired sensing modalities enhance the ability of autonomous vehicles to characterize and respond to their environment. This paper concerns the lateral line of cartilaginous and bony fish, which is sensitive to fluid motion and allows fish to sense oncoming flow and the presence of walls or obstacles. The lateral line consists of two types of sensing modalities: canal neuromasts measure approximate pressure gradients, whereas superficial neuromasts measure local flow velocities. By employing an artificial lateral line, the performance of underwater sensing and navigation strategies is improved in dark, cluttered, or murky environments where traditional sensing modalities may be hindered. This paper presents estimation and control strategies enabling an airfoil-shaped unmanned underwater vehicle to assimilate measurements from a bio-inspired, multi-modal artificial lateral line and estimate flow properties for feedback control. We utilize potential flow theory to model the fluid flow past a foil in a uniform flow and in the presence of an upstream obstacle. We derive theoretically justified nonlinear estimation strategies to estimate the free stream flowspeed, angle of attack, and the relative position of an upstream obstacle. The feedback control strategy uses the estimated flow properties to execute bio-inspired behaviors including rheotaxis (the tendency of fish to orient upstream) and station-holding (the tendency of fish to position behind an upstream obstacle). A robotic prototype outfitted with a multi-modal artificial lateral line composed of ionic polymer metal composite and embedded pressure sensors experimentally demonstrates the distributed flow sensing and closed-loop control strategies.

  6. Separation of magnetic beads in a hybrid continuous flow microfluidic device

    Energy Technology Data Exchange (ETDEWEB)

    Samanta, Abhishek [Haldia Institute of Technology, Production Engineering Department, Haldia (India); Ganguly, Ranjan; Datta, Amitava [Jadavpur University, Power Engineering Department (India); Modak, Nipu, E-mail: nmechju@gmail.com [Jadavpur University, Mechanical Engineering Department (India)

    2017-04-01

    Magnetic separation of biological entities in microfluidic environment is a key task for a large number of bio-analytical protocols. In magnetophoretic separation, biochemically functionalized magnetic beads are allowed to bind selectively to target analytes, which are then separated from the background stream using a suitably imposed magnetic field. Here we present a numerical study, characterizing the performance of a magnetophoretic hybrid microfluidic device having two inlets and three outlets for immunomagnetic isolation of three different species from a continuous flow. The hybrid device works on the principle of split-flow thin (SPLITT) fractionation and field flow fractionation (FFF) mechanisms. Transport of the magnetic particles in the microchannel has been predicted following an Eulerian-Lagrangian model and using an in-house numerical code. Influence of the salient geometrical parameters on the performance of the separator is studied by characterizing the particle trajectories and their capture and separation indices. Finally, optimum channel geometry is identified that yields the maximum capture efficiency and separation index. - Highlights: • Immunomagnetic separation in a hybrid microchannel design is investigated numerically. • Influence of salient geometric parameters on the device performance is analysed. • Optimum device dimension for best separation parameters are identified. • Optimized design of hybrid separator performs better than FFF or SPLITT devices.

  7. Manipulating the Flow of Thermal Noise in Quantum Devices

    Science.gov (United States)

    Barzanjeh, Shabir; Aquilina, Matteo; Xuereb, André

    2018-02-01

    There has been significant interest recently in using complex quantum systems to create effective nonreciprocal dynamics. Proposals have been put forward for the realization of artificial magnetic fields for photons and phonons; experimental progress is fast making these proposals a reality. Much work has concentrated on the use of such systems for controlling the flow of signals, e.g., to create isolators or directional amplifiers for optical signals. In this Letter, we build on this work but move in a different direction. We develop the theory of and discuss a potential realization for the controllable flow of thermal noise in quantum systems. We demonstrate theoretically that the unidirectional flow of thermal noise is possible within quantum cascaded systems. Viewing an optomechanical platform as a cascaded system we show here that one can ultimately control the direction of the flow of thermal noise. By appropriately engineering the mechanical resonator, which acts as an artificial reservoir, the flow of thermal noise can be constrained to a desired direction, yielding a thermal rectifier. The proposed quantum thermal noise rectifier could potentially be used to develop devices such as a thermal modulator, a thermal router, and a thermal amplifier for nanoelectronic devices and superconducting circuits.

  8. A Hydrological Concept including Lateral Water Flow Compatible with the Biogeochemical Model ForSAFE

    Directory of Open Access Journals (Sweden)

    Giuliana Zanchi

    2016-03-01

    Full Text Available The study presents a hydrology concept developed to include lateral water flow in the biogeochemical model ForSAFE. The hydrology concept was evaluated against data collected at Svartberget in the Vindeln Research Forest in Northern Sweden. The results show that the new concept allows simulation of a saturated and an unsaturated zone in the soil as well as water flow that reaches the stream comparable to measurements. The most relevant differences compared to streamflow measurements are that the model simulates a higher base flow in winter and lower flow peaks after snowmelt. These differences are mainly caused by the assumptions made to regulate the percolation at the bottom of the simulated soil columns. The capability for simulating lateral flows and a saturated zone in ForSAFE can greatly improve the simulation of chemical exchange in the soil and export of elements from the soil to watercourses. Such a model can help improve the understanding of how environmental changes in the forest landscape will influence chemical loads to surface waters.

  9. Experimental evidence of lateral flow in unsaturated homogeneous isotropic sloping soil due to rainfall

    NARCIS (Netherlands)

    Sinai, G.; Dirksen, C.

    2006-01-01

    This paper describes laboratory experimental evidence for lateral flow in the top layer of unsaturated sloping soil due to rainfall. Water was applied uniformly on horizontal and V-shaped surfaces of fine sand, at rates about 100 times smaller than the saturated hydraulic conductivity. Flow regimes

  10. A measurement device for electromagnetic flow tomography

    Science.gov (United States)

    Vauhkonen, M.; Hänninen, A.; Lehtikangas, O.

    2018-01-01

    Electromagnetic flow meters have succesfully been used in many industries to measure the mean flow velocity of conductive liquids. This technology works reliably in single phase flows with axisymmetric flow profiles but can be inaccurate with asymmetric flows, which are encountered, for example, in multiphase flows, pipe elbows and T-junctions. Some computational techniques and measurement devices with multiple excitation coils and measurement electrodes have recently been proposed to be used in cases of asymmetric flows. In earlier studies, we proposed a computational approach for electromagnetic flow tomography (EMFT) for estimating velocity fields utilizing several excitation coils and a set of measurement electrodes attached to the surface of the pipe. This approach has been shown to work well with simulated data but has not been tested extensively with real measurements. In this paper, an EMFT system with four excitation coils and 16 measurement electrodes is introduced. The system is capable of using both square wave and sinusoidal coil current excitations and all the coils can be excited individually, also enabling parallel excitations with multiple frequencies. The studies undertaken in the paper demonstrate that the proposed EMFT system, together with the earlier introduced velocity field reconstruction approach, is capable of producing reliable velocify field estimates in a laboratory environment with both axisymmetric and asymmetric single phase flows.

  11. Study on an Axial Flow Hydraulic Turbine with Collection Device

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2014-01-01

    Full Text Available We propose a new type of portable hydraulic turbine that uses the kinetic energy of flow in open channels. The turbine comprises a runner with an appended collection device that includes a diffuser section in an attempt to improve the output by catching and accelerating the flow. With such turbines, the performance of the collection device, and a composite body comprising the runner and collection device were studied using numerical analysis. Among four stand-alone collection devices, the inlet velocity ratio was most improved by the collection device featuring an inlet nozzle and brim. The inlet velocity ratio of the composite body was significantly lower than that of the stand-alone collection device, owing to the resistance of the runner itself, the decreased diffuser pressure recovery coefficient, and the increased backpressure coefficient. However, at the maximum output tip speed ratio, the inlet velocity ratio and the loading coefficient were approximately 31% and 22% higher, respectively, for the composite body than for the isolated runner. In particular, the input power coefficient significantly increased (by approximately 2.76 times owing to the increase in the inlet velocity ratio. Verification tests were also conducted in a real canal to establish the actual effectiveness of the turbine.

  12. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    Science.gov (United States)

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  13. Ulnar nerve injury due to lateral traction device during shoulder arthroscopy: Was it avoidable?

    Directory of Open Access Journals (Sweden)

    Vivek Pandey

    2017-01-01

    Full Text Available Most of the nerve injuries reported during shoulder arthroscopy in a beach chair, or lateral position is related to inappropriate patient positioning or excess traction. The lateral decubitus position is more vulnerable for traction-related neuropraxia. The present case serves as an important lesson from an avoidable situation of “having a one track mind” of the surgical team during the arthroscopic repair of shoulder instability performed in the lateral decubitus position. The operating surgeon must supervise the appropriate positioning of the patient on operation table and adequate padding of vulnerable bony points before beginning of shoulder arthroscopy to prevent any position-related nerve injuries. This is probably the first case to illustrate an unusual cause of ulnar nerve compression particularly related to the use of an additional traction device in the arthroscopic repair of shoulder instability performed in lateral decubitus position, which has not been previously defined.

  14. Carbon nanoparticles in lateral flow methods to detect genes encoding virulence factors of Shiga toxin-producing Escherichia coli

    NARCIS (Netherlands)

    Noguera, P.; Posthuma-Trumpie, G.A.; Tuil, van M.; Wal, van der F.J.; Boer, de A.; Moers, A.P.H.A.; Amerongen, van A.

    2011-01-01

    The use of carbon nanoparticles is shown for the detection and identification of different Shiga toxin-producing Escherichia coli virulence factors (vt1, vt2, eae and ehxA) and a 16S control (specific for E. coli) based on the use of lateral flow strips (nucleic acid lateral flow immunoassay,

  15. Device for measuring the flow rate of a fluid moving through a pipe

    International Nuclear Information System (INIS)

    Barge, Gilles; Bouchard, Patrick; Chaix, J.E.; Rigaud, J.L.; Vivaldi, Andre.

    1981-01-01

    A device is described for measuring the flow rate, in particular through large section pipes, such as those found in water type nuclear reactors, thermal power stations and gas loops. This device includes a plate drilled with holes crossed by a fluid and held in the pipe by deformable components on which are secured strain gauges forming the detecting element of an electronic device for processing the signal emitted by the gauges. This device can be employed, for instance, for measuring the flow rate of a coolant in the primary system of a nuclear reactor [fr

  16. Computational Flow Dynamic Simulation of Micro Flow Field Characteristics Drainage Device Used in the Process of Oil-Water Separation

    Directory of Open Access Journals (Sweden)

    Guangya Jin

    2017-01-01

    Full Text Available Aqueous crude oil often contains large amounts of produced water and heavy sediment, which seriously threats the safety of crude oil storage and transportation. Therefore, the proper design of crude oil tank drainage device is prerequisite for efficient purification of aqueous crude oil. In this work, the composition and physicochemical properties of crude oil samples were tested under the actual conditions encountered. Based on these data, an appropriate crude oil tank drainage device was developed using the principle of floating ball and multiphase flow. In addition, the flow field characteristics in the device were simulated and the contours and streamtraces of velocity magnitude at different nine moments were obtained. Meanwhile, the improvement of flow field characteristics after the addition of grids in crude oil tank drainage device was validated. These findings provide insights into the development of effective selection methods and serve as important references for oil-water separation process.

  17. 3D-printed devices for continuous-flow organic chemistry.

    Science.gov (United States)

    Dragone, Vincenza; Sans, Victor; Rosnes, Mali H; Kitson, Philip J; Cronin, Leroy

    2013-01-01

    We present a study in which the versatility of 3D-printing is combined with the processing advantages of flow chemistry for the synthesis of organic compounds. Robust and inexpensive 3D-printed reactionware devices are easily connected using standard fittings resulting in complex, custom-made flow systems, including multiple reactors in a series with in-line, real-time analysis using an ATR-IR flow cell. As a proof of concept, we utilized two types of organic reactions, imine syntheses and imine reductions, to show how different reactor configurations and substrates give different products.

  18. Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

    International Nuclear Information System (INIS)

    Papell, S.S.; Nyland, T.W.; Saiyed, N.H.

    1992-07-01

    Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomson devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1-X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band. 3 refs

  19. Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters.

    Science.gov (United States)

    Shah, Kamal G; Singh, Vidhi; Kauffman, Peter C; Abe, Koji; Yager, Paul

    2018-05-14

    Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.

  20. Hydrodynamic pressure sensing with an artificial lateral line in steady and unsteady flows

    International Nuclear Information System (INIS)

    Venturelli, Roberto; Akanyeti, Otar; Visentin, Francesco; Fiorini, Paolo; Ježov, Jaas; Toming, Gert; Kruusmaa, Maarja; Chambers, Lily D; Brown, Jennifer; Megill, William M

    2012-01-01

    With the overall goal being a better understanding of the sensing environment from the local perspective of a situated agent, we studied uniform flows and Kármán vortex streets in a frame of reference relevant to a fish or swimming robot. We visualized each flow regime with digital particle image velocimetry and then took local measurements using a rigid body with laterally distributed parallel pressure sensor arrays. Time and frequency domain methods were used to characterize hydrodynamically relevant scenarios in steady and unsteady flows for control applications. Here we report that a distributed pressure sensing mechanism has the capability to discriminate Kármán vortex streets from uniform flows, and determine the orientation and position of the platform with respect to the incoming flow and the centre axis of the Kármán vortex street. It also enables the computation of hydrodynamic features which may be relevant for a robot while interacting with the flow, such as vortex shedding frequency, vortex travelling speed and downstream distance between vortices. A Kármán vortex street was distinguished in this study from uniform flows by analysing the magnitude of fluctuations present in the sensor measurements and the number of sensors detecting the same dominant frequency. In the Kármán vortex street the turbulence intensity was 30% higher than that in the uniform flow and the sensors collectively sensed the vortex shedding frequency as the dominant frequency. The position and orientation of the sensor platform were determined via a comparative analysis between laterally distributed sensor arrays; the vortex travelling speed was estimated via a cross-correlation analysis among the sensors. (paper)

  1. A numerical study of two-phase Stokes flow in an axisymmetric flow-focusing device

    DEFF Research Database (Denmark)

    Jensen, Mads Jakob; Stone, H.A.; Bruus, Henrik

    2006-01-01

    We present a numerical investigation of the time-dependent dynamics of the creation of gas bubbles in an axisymmetric flow-focusing device. The liquid motion is treated as a Stokes flow, and using a generic framework we implement a second-order time-integration scheme and a free-surface model...... in MATLAB, which interfaces with the finite-element software FEMLAB. We derive scaling laws for the volume of a created bubble and for the gas flow rate, and confirm them numerically. Our results are consistent with existing experimental results by Garstecki et al. [Phys. Rev. Lett. 94, 164501 (2005...

  2. A bio-inspired real-time capable artificial lateral line system for freestream flow measurements.

    Science.gov (United States)

    Abels, C; Qualtieri, A; De Vittorio, M; Megill, W M; Rizzi, F

    2016-06-03

    To enhance today's artificial flow sensing capabilities in aerial and underwater robotics, future robots could be equipped with a large number of miniaturized sensors distributed over the surface to provide high resolution measurement of the surrounding fluid flow. In this work we show a linear array of closely separated bio-inspired micro-electro-mechanical flow sensors whose sensing mechanism is based on a piezoresistive strain-gauge along a stress-driven cantilever beam, mimicking the biological superficial neuromasts found in the lateral line organ of fishes. Aiming to improve state-of-the-art flow sensing capability in autonomously flying and swimming robots, our artificial lateral line system was designed and developed to feature multi-parameter freestream flow measurements which provide information about (1) local flow velocities as measured by the signal amplitudes from the individual cantilevers as well as (2) propagation velocity, (3) linear forward/backward direction along the cantilever beam orientation and (4) periodicity of pulses or pulse trains determined by cross-correlating sensor signals. A real-time capable cross-correlation procedure was developed which makes it possible to extract freestream flow direction and velocity information from flow fluctuations. The computed flow velocities deviate from a commercial system by 0.09 m s(-1) at 0.5 m s(-1) and 0.15 m s(-1) at 1.0 m s(-1) flow velocity for a sampling rate of 240 Hz and a sensor distance of 38 mm. Although experiments were performed in air, the presented flow sensing system can be applied to underwater vehicles as well, once the sensors are embedded in a waterproof micro-electro-mechanical systems package.

  3. Automatic coolant flow control device for a nuclear reactor assembly

    Science.gov (United States)

    Hutter, Ernest

    1986-01-01

    A device which controls coolant flow through a nuclear reactor assembly comprises a baffle means at the exit end of said assembly having a plurality of orifices, and a bimetallic member in operative relation to the baffle means such that at increased temperatures said bimetallic member deforms to unblock some of said orifices and allow increased coolant flow therethrough.

  4. Assessing lateral flows and solute transport during floods in a conduit-flow-dominated karst system using the inverse problem for the advection-diffusion equation

    Science.gov (United States)

    Cholet, Cybèle; Charlier, Jean-Baptiste; Moussa, Roger; Steinmann, Marc; Denimal, Sophie

    2017-07-01

    The aim of this study is to present a framework that provides new ways to characterize the spatio-temporal variability of lateral exchanges for water flow and solute transport in a karst conduit network during flood events, treating both the diffusive wave equation and the advection-diffusion equation with the same mathematical approach, assuming uniform lateral flow and solute transport. A solution to the inverse problem for the advection-diffusion equations is then applied to data from two successive gauging stations to simulate flows and solute exchange dynamics after recharge. The study site is the karst conduit network of the Fourbanne aquifer in the French Jura Mountains, which includes two reaches characterizing the network from sinkhole to cave stream to the spring. The model is applied, after separation of the base from the flood components, on discharge and total dissolved solids (TDSs) in order to assess lateral flows and solute concentrations and compare them to help identify water origin. The results showed various lateral contributions in space - between the two reaches located in the unsaturated zone (R1), and in the zone that is both unsaturated and saturated (R2) - as well as in time, according to hydrological conditions. Globally, the two reaches show a distinct response to flood routing, with important lateral inflows on R1 and large outflows on R2. By combining these results with solute exchanges and the analysis of flood routing parameters distribution, we showed that lateral inflows on R1 are the addition of diffuse infiltration (observed whatever the hydrological conditions) and localized infiltration in the secondary conduit network (tributaries) in the unsaturated zone, except in extreme dry periods. On R2, despite inflows on the base component, lateral outflows are observed during floods. This pattern was attributed to the concept of reversal flows of conduit-matrix exchanges, inducing a complex water mixing effect in the saturated zone

  5. Assessing lateral flows and solute transport during floods in a conduit-flow-dominated karst system using the inverse problem for the advection–diffusion equation

    Directory of Open Access Journals (Sweden)

    C. Cholet

    2017-07-01

    Full Text Available The aim of this study is to present a framework that provides new ways to characterize the spatio-temporal variability of lateral exchanges for water flow and solute transport in a karst conduit network during flood events, treating both the diffusive wave equation and the advection–diffusion equation with the same mathematical approach, assuming uniform lateral flow and solute transport. A solution to the inverse problem for the advection–diffusion equations is then applied to data from two successive gauging stations to simulate flows and solute exchange dynamics after recharge. The study site is the karst conduit network of the Fourbanne aquifer in the French Jura Mountains, which includes two reaches characterizing the network from sinkhole to cave stream to the spring. The model is applied, after separation of the base from the flood components, on discharge and total dissolved solids (TDSs in order to assess lateral flows and solute concentrations and compare them to help identify water origin. The results showed various lateral contributions in space – between the two reaches located in the unsaturated zone (R1, and in the zone that is both unsaturated and saturated (R2 – as well as in time, according to hydrological conditions. Globally, the two reaches show a distinct response to flood routing, with important lateral inflows on R1 and large outflows on R2. By combining these results with solute exchanges and the analysis of flood routing parameters distribution, we showed that lateral inflows on R1 are the addition of diffuse infiltration (observed whatever the hydrological conditions and localized infiltration in the secondary conduit network (tributaries in the unsaturated zone, except in extreme dry periods. On R2, despite inflows on the base component, lateral outflows are observed during floods. This pattern was attributed to the concept of reversal flows of conduit–matrix exchanges, inducing a complex water mixing effect

  6. 3D-printed devices for continuous-flow organic chemistry

    Directory of Open Access Journals (Sweden)

    Vincenza Dragone

    2013-05-01

    Full Text Available We present a study in which the versatility of 3D-printing is combined with the processing advantages of flow chemistry for the synthesis of organic compounds. Robust and inexpensive 3D-printed reactionware devices are easily connected using standard fittings resulting in complex, custom-made flow systems, including multiple reactors in a series with in-line, real-time analysis using an ATR-IR flow cell. As a proof of concept, we utilized two types of organic reactions, imine syntheses and imine reductions, to show how different reactor configurations and substrates give different products.

  7. Laterally configured resistive switching device based on transition-metal nano-gap electrode on Gd oxide

    Energy Technology Data Exchange (ETDEWEB)

    Kawakita, Masatoshi; Okabe, Kyota [Department of Physics, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan); Kimura, Takashi [Department of Physics, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan); Research Center for Quantum Nano-Spin Sciences, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan)

    2016-01-11

    We have developed a fabrication process for a laterally configured resistive switching device based on a Gd oxide. A nano-gap electrode connected by a Gd oxide with the ideal interfaces has been created by adapting the electro-migration method in a metal/GdO{sub x} bilayer system. Bipolar set and reset operations have been clearly observed in the Pt/GdO{sub x} system similarly in the vertical device based on GdO{sub x}. Interestingly, we were able to observe a clear bipolar switching also in a ferromagnetic CoFeB nano-gap electrode with better stability compared to the Pt/GdO{sub x} device. The superior performance of the CoFeB/GdO{sub x} device implies the importance of the spin on the resistive switching.

  8. Controllable Microdroplet Splitting via Additional Lateral Flow and its Application in Rapid Synthesis of Multi-scale Microspheres

    KAUST Repository

    Zhou, Bingpu

    2015-01-01

    In this paper, we demonstrate that controllable microdroplet splitting could be obtained via additional lateral flow with simplicity and high controllability. The volume ratio of the two splitting products can be flexibly regulated by adjusting the flow rate ratio between the main and additional lateral flows. The splitting phenomena under different main flow rates were investigated. A volume ratio up to 200 : 1 of the two daughter droplets under a relatively higher main flow rate was experimentally achieved based on our approach. In this case, we have successfully achieved uniform daughter droplets with a smallest diameter of ∼19.5 ± 1.6 μm. With such a design, we have synthesized uniform PEGDA hydrogel microspheres with diameters ranging from ∼30 μm to over hundred of micrometers simultaneously.

  9. Improving Process Quality by Means of Accurate and Traceable Calibration of Flow Devices with Process-oriented Liquids.

    Science.gov (United States)

    Bissig, Hugo; Tschannen, Martin; de Huu, Marc

    2018-03-30

    Calibration of flow devices is important in several areas of pharmaceutical, flow chemistry and health care applications where volumetric dosage or delivery at given flow rates are crucial for the process. Although most of the flow devices are measuring flow rates of process-oriented liquids, their calibrations are often performed with water as calibration liquid. It is recommended to perform the calibrations of the flow devices with process-oriented liquids as the liquid itself might influence the performance of the flow devices. Therefore, METAS has developed facilities with METAS flow generators to address the issue of measuring with process-oriented liquids for flow rates from 400 ml/min down to 50 nl/min with uncertainties from 0.07-0.9 %. Traceability is guaranteed through the calibration of the generated flow rates of the METAS flow generators by means of the dynamic gravimetric method where a liquid of well-known density and a well-controlled evaporation rate is used. The design of the milli-flow facility will be discussed as well as first measurement results of the METAS flow generators in the range of micro-flow and milli-flow using water and other liquids.

  10. COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

    NARCIS (Netherlands)

    Neyt, Mattias; Van den Bruel, Ann; Smit, Yolba; De Jonge, Nicolaas; Erasmus, Michiel; Van Dijk, Diederik; Vlayen, Joan

    Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs.

  11. Large spin-valve effect in a lateral spin-valve device based on ferromagnetic semiconductor GaMnAs

    Science.gov (United States)

    Asahara, Hirokatsu; Kanaki, Toshiki; Ohya, Shinobu; Tanaka, Masaaki

    2018-03-01

    We investigate the spin-dependent transport properties of a lateral spin-valve device based on the ferromagnetic semiconductor GaMnAs. This device is composed of a GaMnAs channel layer grown on GaAs with a narrow trench across the channel. Its current-voltage characteristics show tunneling behavior. Large magnetoresistance (MR) ratios of more than ˜10% are obtained. These values are much larger than those (˜0.1%) reported for lateral-type spin metal-oxide-semiconductor field-effect transistors. The magnetic field direction dependence of the MR curve differs from that of the anisotropic magnetoresistance of GaMnAs, which confirms that the MR signal originates from the spin-valve effect between the GaMnAs electrodes.

  12. An accessible micro-capillary electrophoresis device using surface-tension-driven flow

    Science.gov (United States)

    Mohanty, Swomitra K.; Warrick, Jay; Gorski, Jack; Beebe, David J.

    2010-01-01

    We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom). Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users. PMID:19425002

  13. Influence of lateral groundwater flow in a shallow aquifer on eco-hydrological process in a shrub-grass coexistence semiarid area

    Science.gov (United States)

    Wang, Siru; Sun, Jinhua; Lei, Huimin; Zhu, Qiande; Jiang, Sanyuan

    2017-04-01

    Topography has a considerable influence on eco-hydrological processes resulting from the patterns of solar radiation distribution and lateral water flow. However, not much quantitative information on the contribution of lateral groundwater flow on ecological processes such as vegetation growth and evapo-transpiration is available. To fill this gap, we used a simple eco-hydrological model based on water balance with a 3D groundwater module that uses Darcy's law. This model was applied to a non-contributing area of 50km2 dominated by grassland and shrubland with an underlying shallow aquifer. It was calibrated using manually and remotely sensed vegetation data and water flux data observed by eddy covariance system of two flux towers as well as water table data obtained from HOBO recorders of 40 wells. The results demonstrate that the maximum hydraulic gradient and the maximum flux of lateral groundwater flow reached to 0.156m m-1 and 0.093m3 s-1 respectively. The average annual maximum LAI in grassland, predominantly in low-lying areas, improved by about 5.9% while that in shrubland, predominantly in high-lying areas, remained the same when lateral groundwater flow is considered adequately compared to the case without considering lateral groundwater flow. They also show that LAI is positively and nonlinearly related to evapotranspiration, and that the greater the magnitude of evapotranspiration, the smaller the rate of increase of LAI. The results suggest that lateral groundwater flow should not be neglected when simulating eco-hydrological process in areas with a shallow aquifer.

  14. The effect of visualizing the flow of multimedia content among and inside devices.

    Science.gov (United States)

    Lee, Dong-Seok

    2009-05-01

    This study introduces a user interface, referred to as the flow interface, which provides a graphical representation of the movement of content among and inside audio/video devices. The proposed interface provides a different frame of reference with content-oriented visualization of the generation, manipulation, storage, and display of content as well as input and output. The flow interface was applied to a VCR/DVD recorder combo, one of the most complicated consumer products. A between-group experiment was performed to determine whether the flow interface helps users to perform various tasks and to examine the learning effect of the flow interface, particularly in regard to hooking up and recording tasks. The results showed that participants with access to the flow interface performed better in terms of success rate and elapsed time. In addition, the participants indicated that they could easily understand the flow interface. The potential of the flow interface for application to other audio video devices, and design issues requiring further consideration, are discussed.

  15. CdSe/ZnS Quantum Dot-Labeled Lateral Flow Strips for Rapid and Quantitative Detection of Gastric Cancer Carbohydrate Antigen 72-4

    Science.gov (United States)

    Yan, Xinyu; Wang, Kan; Lu, Wenting; Qin, Weijian; Cui, Daxiang; He, Jinghua

    2016-03-01

    Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.

  16. The clinical use of the device for flowing blood irradiation

    International Nuclear Information System (INIS)

    Arutyunov, A.S.; Karasev, A.B.; Kovalev, O.I.; Pisarevskij, A.A.; Skobennikov, A.K.; Trofimov, V.I.; Khaskel'berg, N.G.

    1988-01-01

    The indications and possibilities of using the device for flowing extracorporeal ultraviolet radiation of blood are considered. The uniformity of the radiation of blood in the proposed device provides an annular gap of the quartz dish with the partition in the shape of a spiral. It makes it possible to expose a larger part of the blood content of an organism simultaneously making use of various perfused methods of its detoxication

  17. Multi-objective optimal power flow with FACTS devices

    International Nuclear Information System (INIS)

    Basu, M.

    2011-01-01

    This paper presents multi-objective differential evolution to optimize cost of generation, emission and active power transmission loss of flexible ac transmission systems (FACTS) device-equipped power systems. In the proposed approach, optimal power flow problem is formulated as a multi-objective optimization problem. FACTS devices considered include thyristor controlled series capacitor (TCSC) and thyristor controlled phase shifter (TCPS). The proposed approach has been examined and tested on the modified IEEE 30-bus and 57-bus test systems. The results obtained from the proposed approach have been compared with those obtained from nondominated sorting genetic algorithm-II, strength pareto evolutionary algorithm 2 and pareto differential evolution.

  18. Touch at a distance sensing: lateral-line inspired MEMS flow sensors

    International Nuclear Information System (INIS)

    Prakash Kottapalli, Ajay Giri; Asadnia, Mohsen; Miao, Jianmin; Triantafyllou, Michael

    2014-01-01

    Evolution bestowed the blind cavefish with a resourcefully designed lateral-line of sensors that play an essential role in many important tasks including object detection and avoidance, energy-efficient maneuvering, rheotaxis etc. Biologists identified the two types of vital sensors on the fish bodies called the superficial neuromasts and the canal neuromasts that are responsible for flow sensing and pressure-gradient sensing, respectively. In this work, we present the design, fabrication and experimental characterization of biomimetic polymer artificial superficial neuromast micro-sensor arrays. These biomimetic micro-sensors demonstrated a high sensitivity of 0.9 mV/(m s −1 ) and 0.022 V/(m s −1 ) and threshold velocity detection limits of 0.1 m s −1 and 0.015 m s −1 in determining air and water flows respectively. Experimental results demonstrate that the biological canal inspired polymer encapsulation on the array of artificial superficial neuromast sensors is capable of filtering steady-state flows that could otherwise significantly mask the relevant oscillatory flow signals of high importance. (paper)

  19. Nuclear assay of coal. Volume 6. Mass flow devices for coal handling

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The mass of coal entering the boiler per unit time is an essential parameter for determinig the total rate of heat input. The mass flow rate of coal on a conveyor belt is generally determined as a product of the instantaneous mass of material on a short section of the belt and the belt velocity. Belt loading could be measured by conventional transducers incorporating mechanical or electromechanical weighers or by gamma-ray attenuation gauge. This report reviews the state of the art in mass flow devices for coal handling. The various methods are compared and commented upon. Special design issues are discussed relative to incorporating a mass flow measuring device in a Continuous On-Line Nuclear Analysis of Coal (CONAC) system

  20. Increased drop formation frequency via reduction of surfactant interactions in flow-focusing microfluidic devices.

    Science.gov (United States)

    Josephides, Dimitris N; Sajjadi, Shahriar

    2015-01-27

    Glass capillary based microfluidic devices are able to create extremely uniform droplets, when formed under the dripping regime, at low setup costs due to their ease of manufacture. However, as they are rarely parallelized, simple methods to increase droplet production from a single device are sought. Surfactants used to stabilize drops in such systems often limit the maximum flow rate that highly uniform drops can be produced due to the lowering interfacial tension causing jetting. In this paper we show that by simple design changes we can limit the interactions of surfactants and maximize uniform droplet production. Three flow-focused configurations are explored: a standard glass capillary device (consisting of a single round capillary inserted into a square capillary), a nozzle fed device, and a surfactant shielding device (both consisting of two round capillaries inserted into either end of a square capillary). In principle, the maximum productivity of uniform droplets is achieved if surfactants are not present. It was found that surfactants in the standard device greatly inhibit droplet production by means of interfacial tension lowering and tip-streaming phenomena. In the nozzle fed configuration, surfactant interactions were greatly limited, yielding flow rates comparable to, but lower than, a surfactant-free system. In the surfactant shielding configuration, flow rates were equal to that of a surfactant-free system and could make uniform droplets at rates an order of magnitude above the standard surfactant system.

  1. Cavitation and gas-liquid flow in fluid machinery and devices. FED-Volume 190

    International Nuclear Information System (INIS)

    O'Hern, T.J.; Kim, J.H.; Morgan, W.B.; Furuya, O.

    1994-01-01

    Cavitation and gas-liquid two-phase flow have remained important areas in many industrial applications and constantly provided challenges for academic researchers and industrial practitioners alike. Cavitation and two-phase flow commonly occur in fluid machinery such as pumps, propellers, and fluid devices such as orifices, valves, and diffusers. Cavitation not only degrades the performance of these machines and devices but deteriorates the materials. Gas-liquid two-phase flow has also been known to degrade the performance of pumps and propellers and can often induce an instability. The industrial applications of cavitation and two-phase flow can be found in power plants, ship propellers, hydrofoils, and aerospace equipment, to name but a few. The papers presented in this volume reflect the variety and richness of cavitation and gas-liquid two-phase flow in various flow transporting components and the increasing role they play in modern and conventional technologies. Separate abstracts were prepared for 35 papers in this book

  2. Experimental studies on the flow characteristics in an inclined bend-free OWC device

    Directory of Open Access Journals (Sweden)

    Krishnil Ravinesh Ram

    2016-01-01

    Full Text Available A bend-free rectangular cross-section OWC device was designed and constructed for studying the effect of inclination on the flow characteristics inside the device. The inclination is meant to reduce reflection of waves and induce higher velocities in the turbine section. Experimental measurements were made in a wave channel where the OWC device was tested. An S-type Pitot tube was used to measure dynamic pressure of air in the turbine section at several inclinations. Particle Image Velocimetry (PIV was also done to study the flow of both air and water in the OWC device. In order to focus solely on primary energy capture, no turbine was installed in the OWC device. The dynamic pressure readings were analysed for suction and compression stages. Water volume fluctuations inside the capture chamber were also recorded and compared for different inclinations. The result was an increase in the velocity of air flowing in the capture chamber and hence a rise in the kinetic energy available to the turbine. It was found from experimental studies that as the angle of inclination reduced, the velocity of air in the turbine section increased. The lower angles also caused higher run-up and larger volume of water into the capture chamber.

  3. Results of testing the E9 multiple probe lateral logging device in deep wells in the eastern Pre-caucasus

    Energy Technology Data Exchange (ETDEWEB)

    Boyarchuk, A.F.; Kochetkov, V.T.; Kucherov, R.A.

    1981-07-01

    The integrated lateral logging device E9 developed for investigating deep and extra-deep wells, permitting measurement of apparent resistances by three probes at different depths, is described. It is heat and pressure resistant (up to 200/degree/C, 120 MPa). The tests showed that under certain favorable conditions the device is fairly effective.

  4. Flow analysis for efficient design of wavy structured microchannel mixing devices

    Science.gov (United States)

    Kanchan, Mithun; Maniyeri, Ranjith

    2018-04-01

    Microfluidics is a rapidly growing field of applied research which is strongly driven by demands of bio-technology and medical innovation. Lab-on-chip (LOC) is one such application which deals with integrating bio-laboratory on micro-channel based single fluidic chip. Since fluid flow in such devices is restricted to laminar regime, designing an efficient passive modulator to induce chaotic mixing for such diffusion based flow is a major challenge. In the present work two-dimensional numerical simulation of viscous incompressible flow is carried out using immersed boundary method (IBM) to obtain an efficient design for wavy structured micro-channel mixing devices. The continuity and Navier-Stokes equations governing the flow are solved by fractional step based finite volume method on a staggered Cartesian grid system. IBM uses Eulerian co-ordinates to describe fluid flow and Lagrangian co-ordinates to describe solid boundary. Dirac delta function is used to couple both these co-ordinate variables. A tether forcing term is used to impose the no-slip boundary condition on the wavy structure and fluid interface. Fluid flow analysis by varying Reynolds number is carried out for four wavy structure models and one straight line model. By analyzing fluid accumulation zones and flow velocities, it can be concluded that straight line structure performs better mixing for low Reynolds number and Model 2 for higher Reynolds number. Thus wavy structures can be incorporated in micro-channels to improve mixing efficiency.

  5. Scaling deterministic lateral displacement arrays for high throughput and dilution-free enrichment of leukocytes

    Science.gov (United States)

    Inglis, David W.; Lord, Megan; Nordon, Robert E.

    2011-05-01

    A disposable device for fractionation of blood into its components that is simple to operate and provides throughput of greater than 1 mL min-1 is highly sought after in medical diagnostics and therapies. This paper describes a device with parallel deterministic lateral displacement devices for enrichment of leukocytes from blood. We show capture of 98% and approximately ten-fold enrichment of leukocytes in whole blood. We demonstrate scaling up through the integration of six parallel devices to achieve a flow rate of 115 µL of undiluted blood per minute per atmosphere of applied pressure.

  6. Lessons from wet gas flow metering systems using differential measurements devices: Testing and flow modelling results

    Energy Technology Data Exchange (ETDEWEB)

    Cazin, J.; Couput, J.P.; Dudezert, C. et al

    2005-07-01

    A significant number of wet gas meters used for high GVF and very high GVF are based on differential pressure measurements. Recent high pressure tests performed on a variety of different DP devices on different flow loops are presented. Application of existing correlations is discussed for several DP devices including Venturi meters. For Venturi meters, deviations vary from 9% when using the Murdock correlation to less than 3 % with physical based models. The use of DP system in a large domain of conditions (Water Liquid Ratio) especially for liquid estimation will require information on the WLR This obviously raises the question of the gas and liquid flow metering accuracy in wet gas meters and highlight needs to understand AP systems behaviour in wet gas flows (annular / mist / annular mist). As an example, experimental results obtained on the influence of liquid film characteristics on a Venturi meter are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film characterization. The AP measurements indicate that for a same Lockhart Martinelli parameter, the characteristics of the two phase flow have a major influence on the correlation coefficient. A 1D model is defined and the results are compared with the experiments. These results indicate that the flow regime influences the AP measurements and that a better modelling of the flow phenomena is needed even for allocation purposes. Based on that, lessons and way forward in wet gas metering systems improvement for allocation and well metering are discussed and proposed. (author) (tk)

  7. Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.

    Science.gov (United States)

    Hodis, Simona; Ding, Yong-Hong; Dai, Daying; Lingineni, Ravi; Mut, Fernando; Cebral, Juan; Kallmes, David; Kadirvel, Ramanathan

    2016-01-01

    Implanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model. Rabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion. Angiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted. Device sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Development of a Nanobody-Based Lateral Flow Immunoassay for Detection of Human Norovirus.

    Science.gov (United States)

    Doerflinger, Sylvie Y; Tabatabai, Julia; Schnitzler, Paul; Farah, Carlo; Rameil, Steffen; Sander, Peter; Koromyslova, Anna; Hansman, Grant S

    2016-01-01

    Human noroviruses are the dominant cause of outbreaks of acute gastroenteritis. These viruses are usually detected by molecular methods, including reverse transcriptase PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA). Human noroviruses are genetically and antigenically diverse, with two main genogroups that are further subdivided into over 40 different genotypes. During the past decade, genogroup 2 genotype 4 (GII.4) has dominated in most countries, but recently, viruses belonging to GII.17 have increased in prevalence in a number of countries. A number of commercially available ELISAs and lateral flow immunoassays were found to have lower sensitivities to the GII.17 viruses, indicating that the antibodies used in these methods may not have a high level of cross-reactivity. In this study, we developed a rapid Nanobody-based lateral flow immunoassay (Nano-immunochromatography [Nano-IC]) for the detection of human norovirus in clinical specimens. The Nano-IC assay detected virions from two GII.4 norovirus clusters, which included the current dominant strain and a novel variant strain. The Nano-IC method had a sensitivity of 80% and specificity of 86% for outbreak specimens. Norovirus virus-like particles (VLPs) representing four genotypes (GII.4, GII.10, GII.12, and GII.17) could be detected by this method, demonstrating the potential in clinical screening. However, further modifications to the Nano-IC method are needed in order to improve this sensitivity, which may be achieved by the addition of other broadly reactive Nanobodies to the system. IMPORTANCE We previously identified a Nanobody (termed Nano-85) that bound to a highly conserved region on the norovirus capsid. In this study, the Nanobody was biotinylated and gold conjugated for a lateral flow immunoassay (termed Nano-IC). We showed that the Nano-IC assay was capable of detecting at least four antigenically distinct GII genotypes, including the newly emerging GII.17. In the clinical setting, the

  9. Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha

    Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.

  10. Student-Fabricated Microfluidic Devices as Flow Reactors for Organic and Inorganic Synthesis

    Science.gov (United States)

    Feng, Z. Vivian; Edelman, Kate R.; Swanson, Benjamin P.

    2015-01-01

    Flow synthesis in microfluidic devices has been rapidly adapted in the pharmaceutical industry and in many research laboratories. Yet, the cost of commercial flow reactors is a major factor limiting the dissemination of this technology in the undergraduate curriculum. Here, we present a laboratory activity where students design and fabricate…

  11. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

    Science.gov (United States)

    Frölich, Andreas Maximilian; Nawka, Marie Teresa; Ernst, Marielle; Frischmuth, Isabell; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-01-01

    Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.

  12. Bubble Formation in Yield Stress Fluids Using Flow-Focusing and T-Junction Devices.

    Science.gov (United States)

    Laborie, Benoit; Rouyer, Florence; Angelescu, Dan E; Lorenceau, Elise

    2015-05-22

    We study the production of bubbles inside yield stress fluids (YSFs) in axisymmetric T-junction and flow-focusing devices. Taking advantage of yield stress over capillary stress, we exhibit a robust break-up mechanism reminiscent of the geometrical operating regime in 2D flow-focusing devices for Newtonian fluids. We report that when the gas is pressure driven, the dynamics is unsteady due to hydrodynamic feedback and YSF deposition on the walls of the channels. However, the present study also identifies pathways for potential steady-state production of bubbly YSFs at large scale.

  13. Lateral and vertical facies relationships of bedforms deposited by aggrading supercritical flows: From cyclic steps to humpback dunes

    Science.gov (United States)

    Lang, Jörg; Winsemann, Jutta

    2013-10-01

    The preservation of bedforms related to supercritical flows and hydraulic jumps is commonly considered to be rare in the geologic record, although these bedforms are known from a variety of depositional environments. This field-based study presents a detailed analysis of the sedimentary facies and stacking pattern of deposits of cyclic steps, chutes-and-pools, antidunes and humpback dunes from three-dimensional outcrops. The well exposed Middle Pleistocene successions from northern Germany comprise glacilacustrine ice-contact subaqueous fan and glacial lake-outburst flood deposits. The studied successions give new insights into the depositional architecture of bedforms related to supercritical flows and may serve as an analogue for other high-energy depositional environments such as fluvial settings, coarse-grained deltas or turbidite systems. Deposits of cyclic steps occur within the glacial lake-outburst flood succession and are characterised by lenticular scours infilled by gently to steeply dipping backsets. Cyclic steps formed due to acceleration and flow thinning when the glacial lake-outburst flood spilled over a push-moraine ridge. These bedforms are commonly laterally and vertically truncated and alternate with deposits of chutes-and-pools and antidunes. The subaqueous fan successions are dominated by laterally extensive sinusoidal waveforms, which are interpreted as deposits of aggrading stationary antidunes, which require quasi-steady flows at the lower limit of the supercritical flow stage and high rates of sedimentation. Humpback dunes are characterised by downflow divergent cross-stratification, displaying differentiation into topsets, foresets and bottomsets, and are interpreted as deposited at the transition from subcritical to supercritical flow conditions or vice versa. Gradual lateral and vertical transitions between humpback dunes and antidune deposits are very common. The absence of planar-parallel stratification in all studied successions

  14. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  15. Acoustic programming in step-split-flow lateral-transport thin fractionation.

    Science.gov (United States)

    Ratier, Claire; Hoyos, Mauricio

    2010-02-15

    We propose a new separation scheme for micrometer-sized particles combining acoustic forces and gravitational field in split-flow lateral-transport thin (SPLITT)-like fractionation channels. Acoustic forces are generated by ultrasonic standing waves set up in the channel thickness. We report on the separation of latex particles of two different sizes in a preliminary experiment using this proposed hydrodynamic acoustic sorter, HAS. Total binary separation of 5 and 10 microm diameter particles has been achieved. Numerical simulations of trajectories of particles flowing through a step-SPLITT under the conditions which combine acoustic standing waves and gravity show a very good agreement with the experiment. Calculations in order to compare separations obtained by the acoustic programming s-SPLITT fractionation and the conventional SPLITT fractionation show that the improvement in separation time is around 1 order of magnitude and could still be improved; this is the major finding of this work. This separation technique can be extended to biomimetic particles and blood cells.

  16. Effect of swirling device on flow behavior in a supersonic separator for natural gas dehydration

    DEFF Research Database (Denmark)

    Wen, Chuang; Li, Anqi; Walther, Jens Honore

    2016-01-01

    is designed for an annular supersonic separator. The supersonic swirling separation flow of natural gas is calculated using the Reynolds Stress model. The results show that the viscous heating and strong swirling flow cause the adverse pressure in the annular channel, which may negatively affect......The supersonic separator is a revolutionary device to remove the condensable components from gas mixtures. One of the key issues for this novel technology is the complex supersonic swirling flow that is not well understood. A swirling device composed of an ellipsoid and several helical blades...

  17. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    Science.gov (United States)

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  18. [A capillary blood flow velocity detection system based on linear array charge-coupled devices].

    Science.gov (United States)

    Zhou, Houming; Wang, Ruofeng; Dang, Qi; Yang, Li; Wang, Xiang

    2017-12-01

    In order to detect the flow characteristics of blood samples in the capillary, this paper introduces a blood flow velocity measurement system based on field-programmable gate array (FPGA), linear charge-coupled devices (CCD) and personal computer (PC) software structure. Based on the analysis of the TCD1703C and AD9826 device data sheets, Verilog HDL hardware description language was used to design and simulate the driver. Image signal acquisition and the extraction of the real-time edge information of the blood sample were carried out synchronously in the FPGA. Then a series of discrete displacement were performed in a differential operation to scan each of the blood samples displacement, so that the sample flow rate could be obtained. Finally, the feasibility of the blood flow velocity detection system was verified by simulation and debugging. After drawing the flow velocity curve and analyzing the velocity characteristics, the significance of measuring blood flow velocity is analyzed. The results show that the measurement of the system is less time-consuming and less complex than other flow rate monitoring schemes.

  19. Knowledge of spacer device, peak flow meter and inhaler technique ...

    African Journals Online (AJOL)

    Background: Metered dose inhalers are cornerstone in effective management of bronchial asthma when correctly used. Most studies hitherto have focused on assessing patient's knowledge of inhaler technique. We sought to assess the knowledge of inhaler technique, spacer device and peak flow meter among doctors and ...

  20. Corpuls cpr resuscitation device generates superior emulated flows and pressures than LUCAS II in a mechanical thorax model.

    Science.gov (United States)

    Eichhorn, S; Mendoza Garcia, A; Polski, M; Spindler, J; Stroh, A; Heller, M; Lange, R; Krane, M

    2017-06-01

    The provision of sufficient chest compression is among the most important factors influencing patient survival during cardiopulmonary resuscitation (CPR). One approach to optimize the quality of chest compressions is to use mechanical-resuscitation devices. The aim of this study was to compare a new device for chest compression (corpuls cpr) with an established device (LUCAS II). We used a mechanical thorax model consisting of a chest with variable stiffness and an integrated heart chamber which generated blood flow dependent on the compression depth and waveform. The method of blood-flow generation could be changed between direct cardiac-compression mode and thoracic-pump mode. Different chest-stiffness settings and compression modes were tested to generate various blood-flow profiles. Additionally, an endurance test at high stiffness was performed to measure overall performance and compression consistency. Both resuscitation machines were able to compress the model thorax with a frequency of 100/min and a depth of 5 cm, independent of the chosen chest stiffness. Both devices passed the endurance test without difficulty. The corpuls cpr device was able to generate about 10-40% more blood flow than the LUCAS II device, depending on the model settings. In most scenarios, the corpuls cpr device also generated a higher blood pressure than the LUCAS II. The peak compression forces during CPR were about 30% higher using the corpuls cpr device than with the LUCAS II. In this study, the corpuls cpr device had improved blood flow and pressure outcomes than the LUCAS II device. Further examination in an animal model is required to prove the findings of this preliminary study.

  1. Nasal high flow therapy: a novel treatment rather than a more expensive oxygen device

    Directory of Open Access Journals (Sweden)

    Eleni Ischaki

    2017-09-01

    Full Text Available Nasal high flow is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. The administration of a high flow of heated and humidified gas mixture promotes higher and more stable inspiratory oxygen fraction values, decreases anatomical dead space and generates a positive airway pressure that can reduce the work of breathing and enhance patient comfort and tolerance. Nasal high flow has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxaemic respiratory failure, with the majority of studies showing positive results. Recently, its clinical indications have been expanded to post-extubated patients in intensive care or following surgery, for pre- and peri-oxygenation during intubation, during bronchoscopy, in immunocompromised patients and in patients with “do not intubate” status. In the present review, we differentiate studies that suggest an advantage (benefit from other studies that do not suggest an advantage (no benefit compared to conventional oxygen devices or noninvasive ventilation, and propose an algorithm in cases of nasal high flow application in patients with acute hypoxaemic respiratory failure of almost any cause.

  2. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  3. Identification of microfluidic two-phase flow patterns in lab-on-chip devices.

    Science.gov (United States)

    Yang, Zhaochu; Dong, Tao; Halvorsen, Einar

    2014-01-01

    This work describes a capacitive sensor for identification of microfluidic two-phase flow in lab-on-chip devices. With interdigital electrodes and thin insulation layer utilized, this sensor is capable of being integrated with the microsystems easily. Transducing principle and design considerations are presented with respect to the microfluidic gas/liquid flow patterns. Numerical simulation results verify the operational principle. And the factors affecting the performance of the sensor are discussed. Besides, a feasible process flow for the fabrication is also proposed.

  4. Morphological resilience to flow fluctuations of fine sediment deposits in bank lateral cavities

    Science.gov (United States)

    Juez, C.; Thalmann, M.; Schleiss, A. J.; Franca, M. J.

    2018-05-01

    Lateral cavities are built in the banks of rivers for several purposes: to create harbors, to capture sediment, to keep a central navigable channel (i.e., Casiers de Girardon in the Rhone river) or to promote the formation of aquatic habitats if a limited amount of sediment is captured, providing hydraulic and morphologic diversity (i.e., the case of Japanese Wandos). This work is focused on this latter purpose: promotion of hydraulic and morphologic diversity. In these scenarios, an increase in the flow discharge in the main channel may, however, re-mobilize the deposit of sediment inside these lateral embayments and cause a sudden increase of the sediment concentration and turbidity in the main channel. It is thus of interest to characterize the resistance and resilience of these sedimentary deposits when the main channel is subjected to high flow or flushing events. Laboratory tests were carried out for five different normalized geometries of the cavities installed in the banks of an open channel and for five hydrographs with different levels of unsteadiness. Water depth, sediment deposit mass, sediment concentration and area covered by the settled sediments were recorded throughout each experiment. Although sediment deposits established at equilibrium before the flushing events are different depending on the geometry of the cavities, generally, they are recovered after being flushed by the high flow events. It is shown that the resistance and resilience of the sediment deposits are strongly dependent on the flow field and the mass exchange between the main channel and the cavities. This mass exchange is governed by the geometry of the cavities and the magnitude of the hydrographs applied.

  5. Rapid detection of fungal alpha-amylase in the work environment with a lateral flow immunoassay

    NARCIS (Netherlands)

    Bogdanovic, J.; Koets, M.; Sander, I.; Wouters, I.; Meijster, T.; Heederik, D.J.J.; Amerongen, van A.; Doekes, G.

    2006-01-01

    Background Occupational allergen exposure assessment usually requires airborne dust sampling at the worksite followed by dust extraction and enzyme immunoassay (EIA) analysis at the laboratory. Use of semiquantitative lateral flow immunoassays (LFIAs) may allow a more rapid detection procedure with

  6. Subsurface lateral flow from hillslope and its contribution to nitrate loading in streams through an agricultural catchment during subtropical rainstorm events

    Directory of Open Access Journals (Sweden)

    B. Zhang

    2011-10-01

    Full Text Available Subsurface lateral flow from agricultural hillslopes is often overlooked compared with overland flow and tile drain flow, partly due to the difficulties in monitoring and quantifying. The objectives of this study were to examine how subsurface lateral flow generated through soil pedons from cropped hillslopes and to quantify its contribution to nitrate loading in the streams through an agricultural catchment in the subtropical region of China. Profiles of soil water potential along hillslopes and stream hydro-chemographs in a trenched stream below a cropped hillslope and at the catchment outlet were simultaneously recorded during two rainstorm events. The dynamics of soil water potential showed positive matrix soil water potential over impermeable soil layer at 0.6 to 1.50 m depths during and after the storms, indicating soil water saturation and drainage processes along the hillslopes irrespective of land uses. The hydro-chemographs in the streams, one trenched below a cropped hillslope and one at the catchment outlet, showed that the concentrations of particulate nitrogen and phosphorus corresponded well to stream flow during the storm, while the nitrate concentration increased on the recession limbs of the hydrographs after the end of the storm. All the synchronous data revealed that nitrate was delivered from the cropped hillslope through subsurface lateral flow to the streams during and after the end of the rainstorms. A chemical mixing model based on electricity conductivity (EC and H+ concentration was successfully established, particularly for the trenched stream. The results showed that the subsurface lateral flow accounted for 29% to 45% of total stream flow in the trenched stream, responsible for 86% of total NO3-N loss (or 26% of total N loss, and for 5.7% to 7.3% of total stream flow at the catchment outlet, responsible for about 69% of total NO3-N loss (or 28% of total N

  7. A fluorometric lateral flow assay for visual detection of nucleic acids using a digital camera readout.

    Science.gov (United States)

    Magiati, Maria; Sevastou, Areti; Kalogianni, Despina P

    2018-06-04

    A fluorometric lateral flow assay has been developed for the detection of nucleic acids. The fluorophores phycoerythrin (PE) and fluorescein isothiocyanate (FITC) were used as labels, while a common digital camera and a colored vinyl-sheet, acting as a cut-off optical filter, are used for fluorescence imaging. After DNA amplification by polymerase chain reaction (PCR), the biotinylated PCR product is hybridized to its complementary probe that carries a poly(dA) tail at 3΄ edge and then applied to the lateral flow strip. The hybrids are captured to the test zone of the strip by immobilized poly(dT) sequences and detected by streptavidin-fluorescein and streptavidin-phycoerythrin conjugates, through streptavidin-biotin interaction. The assay is widely applicable, simple, cost-effective, and offers a large multiplexing potential. Its performance is comparable to assays based on the use of streptavidin-gold nanoparticles conjugates. As low as 7.8 fmol of a ssDNA and 12.5 fmol of an amplified dsDNA target were detectable. Graphical abstract Schematic presentation of a fluorometric lateral flow assay based on fluorescein and phycoerythrin fluorescent labels for the detection of single-stranded (ssDNA) and double-stranded DNA (dsDNA) sequences and using a digital camera readout. SA: streptavidin, BSA: Bovine Serum Albumin, B: biotin, FITC: fluorescein isothiocyanate, PE: phycoerythrin, TZ: test zone, CZ: control zone.

  8. Device for preventing cooling water from flowing out of reactor

    International Nuclear Information System (INIS)

    Chinen, Masanori; Kotani, Koichi; Murase, Michio.

    1976-01-01

    Object: To provide emergency cooling system, which can prevent cooling water bearing radioactivity from flowing to the outside of the reactor at the time of breakage of feedwater pipe, thus eliminating the possibility of exposure of the fuel rod to provide high reliability and also reducing the possibility of causing radioactive pollution. Structure: The device for preventing cooling water from flowing out from the reactor features a jet nozzle inserted in a feedwater pipe adjacent to the inlet or outlet thereof immediately before the reactor container. The nozzle outlet is provided in the vicinity of the reactor wall and in a direction opposite to the direction of out-flow, and water supplied from a high pressure pump is jetted from it. (Nakamura, S.)

  9. High energy density redox flow device

    Science.gov (United States)

    Chiang, Yet-Ming; Carter, William Craig; Duduta, Mihai; Limthongkul, Pimpa

    2014-05-13

    Redox flow devices are described including a positive electrode current collector, a negative electrode current collector, and an ion-permeable membrane separating said positive and negative current collectors, positioned and arranged to define a positive electroactive zone and a negative electroactive zone; wherein at least one of said positive and negative electroactive zone comprises a flowable semi-solid composition comprising ion storage compound particles capable of taking up or releasing said ions during operation of the cell, and wherein the ion storage compound particles have a polydisperse size distribution in which the finest particles present in at least 5 vol % of the total volume, is at least a factor of 5 smaller than the largest particles present in at least 5 vol % of the total volume.

  10. Isothermal Amplification and Lateral-Flow Assay for Detecting Crown-Gall-Causing Agrobacterium spp.

    Science.gov (United States)

    Fuller, Skylar L; Savory, Elizabeth A; Weisberg, Alexandra J; Buser, Jessica Z; Gordon, Michael I; Putnam, Melodie L; Chang, Jeff H

    2017-09-01

    Agrobacterium is a genus of soilborne gram-negative bacteria. Members carrying oncogenic plasmids can cause crown gall disease, which has significant economic costs, especially for the orchard and nursery industries. Early and rapid detection of pathogenic Agrobacterium spp. is key to the management of crown gall disease. To this end, we designed oligonucleotide primers and probes to target virD2 for use in a molecular diagnostic tool that relies on isothermal amplification and lateral-flow-based detection. The oligonucleotide tools were tested in the assay and evaluated for detection limit and specificity in detecting alleles of virD2. One set of primers that successfully amplified virD2 when used with an isothermal recombinase was selected. Both tested probes had detection limits in picogram amounts of DNA. Probe 1 could detect all tested pathogenic isolates that represented most of the diversity of virD2. Finally, the coupling of lateral-flow detection to the use of these oligonucleotide primers in isothermal amplification helped to reduce the onerousness of the process, and alleviated reliance on specialized tools necessary for molecular diagnostics. The assay is an advancement for the rapid molecular detection of pathogenic Agrobacterium spp.

  11. Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel

    Science.gov (United States)

    McQuillen, John B.; Chao, David F.; Hall, Nancy R.; Zhang, Nengli

    2012-01-01

    A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.

  12. Nuclear assay of coal. Volume 6. Mass flow devices for coal handling. Final report

    International Nuclear Information System (INIS)

    Gozani, T.; Elias, E.; Bevan, R.

    1980-04-01

    The mass of coal entering the boiler per unit time is an essential parameter for determining the total rate of heat input. The mass flow rate of coal on a conveyor belt is generally determined as a product of the instantaneous mass of material on a short section of the belt and the belt velocity. Belt loading could be measured by conventional transducers incorporating mechanical or electromechanical weighers or by gamma-ray attenuation gauge. This report reviews the state of the art in mass flow devices for coal handling. The various methods are compared and commented upon. Special design issues are discussed relative to incorporating a mass flow measuring device in a Continuous On-Line Nuclear Analysis of Coal (CONAC) system

  13. Numerical flow simulation methods and additive manufacturing methods for the development of a flow optimised design of a novel point-of-care diagnostic device

    Directory of Open Access Journals (Sweden)

    Dethloff Manuel

    2017-09-01

    Full Text Available For the development of a novel, user-friendly and low cost point-of-care diagnostic device for the detection of disease specific biomarker a flow optimised design of the test system has to be investigated. The resulting test system is characterised by a reduced execution period, a reduction of execution steps and an integrated waste management. Based on previous results, the current study focused on the design implementation of the fluidic requirements, e. g. tightness, inside the test device. With the help of fluid flow simulations (CFD – computational fluid dynamics the flow behaviour inside the test device was analysed for different designs and arrangements. Prototypes generated from additive manufacturing technologies (PolyJet modeling are used for validating the simulation results and further experimental tests.

  14. Study on Helicopter Antitorque Device Based on Cross-Flow Fan Technology

    Directory of Open Access Journals (Sweden)

    Du Siliang

    2016-01-01

    Full Text Available In order to improve low-altitude flight security of single-rotor helicopter, an experimental model of a helicopter antitorque device is developed for wind tunnel test. The model is based on the flow control technology of the cross-flow fan (CFF. Wind tunnel tests show that the model can produce side force. It is concluded that the influence of the CFF rotating speed, the rotor collective pitch, and the forward flight speed on the side force of the model is great. At the same time, the numerical simulation calculation method of the model has been established. Good agreement between experimental and numerical side force and power shows that results of numerical solution are reliable. Therefore, the results in actual helicopter obtained from Computational Fluid Dynamics (CFD solution are acceptable. This proves that this antitorque device can be used for a helicopter.

  15. Detection of Shiga Toxins by Lateral Flow Assay

    Directory of Open Access Journals (Sweden)

    Kathryn H. Ching

    2015-04-01

    Full Text Available Shiga toxin-producing Escherichia coli (STEC produce shiga toxins (Stxs that can cause human disease and death. The contamination of food products with STEC represents a food safety problem that necessitates rapid and effective detection strategies to mitigate risk. In this manuscript, we report the development of a colorimetric lateral flow assay (LFA for the rapid detection of Stxs in <10 min using a pair of monoclonal antibodies that bind epitopes common to Stx1 and six Stx2 variants. This LFA provides a rapid and sensitive test for the detection of Stxs directly from STEC culture supernatants or at risk food samples with a 0.1 ng/mL limit of detection (LOD for Stx2a. This Stx LFA is applicable for use in the rapid evaluation of Stx production from cultured E. coli strains or as a tool to augment current methods as part of food safety testing.

  16. Identifying the best locations to install flow control devices in sewer networks to enable in-sewer storage

    Science.gov (United States)

    Leitão, J. P.; Carbajal, J. P.; Rieckermann, J.; Simões, N. E.; Sá Marques, A.; de Sousa, L. M.

    2018-01-01

    The activation of available in-sewer storage volume has been suggested as a low-cost flood and combined sewer overflow mitigation measure. However, it is currently unknown what the attributes for suitable objective functions to identify the best location for flow control devices are and the impact of those attributes on the results. In this study, we present a novel location model and efficient algorithm to identify the best location(s) to install flow limiters. The model is a screening tool that does not require hydraulic simulations but rather considers steady state instead of simplistic static flow conditions. It also maximises in-sewer storage according to different reward functions that also considers the potential impact of flow control device failure. We demonstrate its usefulness on two real sewer networks, for which an in-sewer storage potential of approximately 2,000 m3 and 500 m3 was estimated with five flow control devices installed.

  17. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  18. Flow characterization and patch clamp dose responses using jet microfluidics in a tubeless microfluidic device.

    Science.gov (United States)

    Resto, Pedro J; Bhat, Abhishek; Stava, Eric; Lor, Chong; Merriam, Elliot; Diaz-Rivera, Ruben E; Pearce, Robert; Blick, Robert; Williams, Justin C

    2017-11-01

    Surface tension passive pumping is a way to actuate flow without the need for pumps, tubing or valves by using the pressure inside small drop to move liquid via a microfluidic channel. These types of tubeless devices have typically been used in cell biology. Herein we present the use of tubeless devices as a fluid exchange platform for patch clamp electrophysiology. Inertia from high-speed droplets and jets is used to create flow and perform on-the-fly mixing of solutions. These are then flowed over GABA transfected HEK cells under patch in order to perform a dose response analysis. TIRF imaging and electrical recordings are used to study the fluid exchange properties of the microfluidic device, resulting in 0-90% fluid exchange times of hundreds of milliseconds. COMSOL is used to model flow and fluid exchange within the device. Patch-clamping experiments show the ability to use high-speed passive pumping and its derivatives for studying peak dose responses, but not for studying ion channel kinetics. Our system results in fluid exchange times slower than when using a standard 12-barrel application system and is not as stable as traditional methods, but it offers a new platform with added functionality. Surface tension passive pumping and tubeless devices can be used in a limited fashion for electrophysiology. Users may obtain peak dose responses but the system, in its current form, is not capable of fluid exchange fast enough to study the kinetics of most ion channels. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Honeybees' speed depends on dorsal as well as lateral, ventral and frontal optic flows.

    Directory of Open Access Journals (Sweden)

    Geoffrey Portelli

    Full Text Available Flying insects use the optic flow to navigate safely in unfamiliar environments, especially by adjusting their speed and their clearance from surrounding objects. It has not yet been established, however, which specific parts of the optical flow field insects use to control their speed. With a view to answering this question, freely flying honeybees were trained to fly along a specially designed tunnel including two successive tapering parts: the first part was tapered in the vertical plane and the second one, in the horizontal plane. The honeybees were found to adjust their speed on the basis of the optic flow they perceived not only in the lateral and ventral parts of their visual field, but also in the dorsal part. More specifically, the honeybees' speed varied monotonically, depending on the minimum cross-section of the tunnel, regardless of whether the narrowing occurred in the horizontal or vertical plane. The honeybees' speed decreased or increased whenever the minimum cross-section decreased or increased. In other words, the larger sum of the two opposite optic flows in the horizontal and vertical planes was kept practically constant thanks to the speed control performed by the honeybees upon encountering a narrowing of the tunnel. The previously described ALIS ("AutopiLot using an Insect-based vision System" model nicely matches the present behavioral findings. The ALIS model is based on a feedback control scheme that explains how honeybees may keep their speed proportional to the minimum local cross-section of a tunnel, based solely on optic flow processing, without any need for speedometers or rangefinders. The present behavioral findings suggest how flying insects may succeed in adjusting their speed in their complex foraging environments, while at the same time adjusting their distance not only from lateral and ventral objects but also from those located in their dorsal visual field.

  20. Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

    Energy Technology Data Exchange (ETDEWEB)

    Du, Dan; Wang, Jun; Wang, Limin; Lu, Donglai; Lin, Yuehe

    2012-02-08

    An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

  1. A Pressure Controlled Pinched Flow Fractionation Device for Continuous Particle Separation

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann; Trosborg, Jacqueline; Tanzi, Simone

    2012-01-01

    In this work the problem of separating small particles of di↵erent sizes is solved by developing a simple microfluidic device using pinched flow fractionation (PFF), a technique originally presented by Yamada et al. in 2004 [1]. The present work takes the concept of PFF to the next level by makin...... Polymers GmbH) using a micro machined silicon master. The functionality of the device was confirmed using polymer beads, and by adjusting the pressure accordingly a complete separation of 2 μm and 4.5 μm beads was demonstrated....

  2. Imaging modes for potential mapping in semiconductor devices by electron holography with improved lateral resolution

    Energy Technology Data Exchange (ETDEWEB)

    Sickmann, Jan, E-mail: jan.sickmann@triebenberg.de [Triebenberg Laboratory, Institute of Structure Physics, Technische Universitaet Dresden, 01069 Dresden (Germany); Formanek, Petr; Linck, Martin [Triebenberg Laboratory, Institute of Structure Physics, Technische Universitaet Dresden, 01069 Dresden (Germany); Muehle, Uwe [Institut fuer Werkstoffwissenschaft, Technische Universitaet Bergakademie Freiberg, 09599 Freiberg (Germany); Lichte, Hannes [Triebenberg Laboratory, Institute of Structure Physics, Technische Universitaet Dresden, 01069 Dresden (Germany)

    2011-03-15

    Electron holography is the highest resolving tool for dopant profiling at nanometre-scale resolution. In order to measure the object areas of interest in a hologram, both a wide field of view and a sufficient lateral resolution are required. The usual path of rays for recording holograms with an electron biprism using the standard objective lens does not meet these requirements, because the field of view amounts to some 10 nm only, however, at a resolution of 0.1 nm better than needed here. Therefore, instead of the standard objective lens, the Lorentz lens is widely used for holography of semiconductors, since it provides a field of view up to 1000 nm at a sufficient lateral resolution of about 10 nm. Since the size of semiconductor structures is steadily shrinking, there is now a need for better lateral resolution at an appropriate field of view. Therefore, additional paths of rays for recording holograms are studied with special emphasis on the parameters field of view and lateral resolution. The findings allow an optimized scheme with a field of view of 200 nm and a lateral resolution of 3.3 nm filling the gap between the existing set-ups. In addition, the Lorentz lens is no longer required for investigation of non-magnetic materials, since the new paths of rays are realized with the standard objective lens and diffraction lens. An example proves the applicability of this arrangement for future semiconductor technology. -- Research highlights: {yields} Imaging modes for potential mapping in semiconductor devices by electron holography. {yields} Using objective and diffraction lens for imaging instead of Lorentz lens. {yields} Detailed investigation of four different paths of rays and its basic parameters for holographic application: field of view, lateral resolution, signal resolution. {yields} Measuring the phase profile of a field effect transistor with 3 nm lateral resolution at field of view of 200 nm.

  3. Inertia thermonuclear device

    International Nuclear Information System (INIS)

    Madarame, Haruki; Nakamura, Norio; Oomura, Hiroshi.

    1983-01-01

    Purpose: To enable effective recovery of the thermonuclear reaction energy and effective protection of a cylinder metal against thermal destruction by forming a uniform and stable liquid metal wall to the inside of a cylindrical member. Constitution: Cylindrical body having a lateral axis is rotatably supported so that a liquid metal wall for use in the wet wall type thermonuclear device is formed centrifugally. A liquid metal injection port for injecting the liquid metal to the cylindrical member is disposed to the lateral axis and a liquid metal exit for flowing out the injected liquid metal is disposed to the body of the cylindrical member, so as to form a moving liquid metal layer flowing from the injection port through the inner circumferential surface of the cylindrical member to the liquid metal exit port. Then, the liquid metal is centrifugally forced to the inner surface of the cylindrical body to form a uniform and stable liquid metal wall at the inner surface of the cylindrical body, whereby the reaction energy can effectively be recovered and the cylinder metal can effectively be protected against thermal destruction. (Yoshihara, H.)

  4. Use of UPFC device controlled by fuzzy logic controllers for decoupled power flow control

    Directory of Open Access Journals (Sweden)

    Ivković Sanja

    2014-01-01

    Full Text Available This paper investigates the possibility of decoupled active and reactive power flow control in a power system using a UPFC device controlled by fuzzy logic controllers. A Brief theoretical review of the operation principles and applications of UPFC devices and design principles of the fuzzy logic controller used are given. A Matlab/Simulink model of the system with UPFC, the fuzzy controller setup, and graphs of the results are presented. Conclusions are drawn regarding the possibility of using this system for decoupled control of the power flow in power systems based on analysis of these graphs.

  5. Radially sheared azimuthal flows and turbulent transport in a cylindrical helicon plasma device

    International Nuclear Information System (INIS)

    Tynan, G R; Burin, M J; Holland, C; Antar, G; Diamond, P H

    2004-01-01

    A radially sheared azimuthal flow is observed in a cylindrical helicon plasma device. The shear flow is roughly azimuthally symmetric and contains both time-stationary and slowly varying components. The turbulent radial particle flux is found to peak near the density gradient maximum and vanishes at the shear layer location. The shape of the radial plasma potential profile associated with the azimuthal E x B flow is predicted accurately by theory. The existence of the mean shear flow in a plasma with finite flow damping from ion-neutral collisions and no external momentum input implies the existence of radial angular momentum transport from the turbulent Reynolds-stress

  6. Device for passive flow control around vertical axis marine turbine

    Science.gov (United States)

    Coşoiu, C. I.; Georgescu, A. M.; Degeratu, M.; Haşegan, L.; Hlevca, D.

    2012-11-01

    The power supplied by a turbine with the rotor placed in a free stream flow may be increased by augmenting the velocity in the rotor area. The energy of the free flow is dispersed and it may be concentrated by placing a profiled structure around the bare turbine in order to concentrate more energy in the rotor zone. At the Aerodynamic and Wind Engineering Laboratory (LAIV) of the Technical University of Civil Engineering of Bucharest (UTCB) it was developed a concentrating housing to be used for hydro or aeolian horizontal axis wind turbines, in order to increase the available energy in the active section of turbine rotor. The shape of the concentrating housing results by superposing several aero/hydro dynamic effects, the most important being the one generated by the passive flow control devices that were included in the housing structure. Those concentrating housings may be also adapted for hydro or aeolian turbines with vertical axis. The present paper details the numerical research effectuated at the LAIV to determine the performances of a vertical axis marine turbine equipped with such a concentrating device, in order to increase the energy quantity extracted from the main flow. The turbine is a Darrieus type one with three vertical straight blades, symmetric with respect to the axis of rotation, generated using a NACA4518 airfoil. The global performances of the turbine equipped with the concentrating housing were compared to the same characteristics of the bare turbine. In order to validate the numerical approach used in this paper, test cases from the literature resulting from experimental and numerical simulations for similar situations, were used.

  7. Device for passive flow control around vertical axis marine turbine

    International Nuclear Information System (INIS)

    Coşoiu, C I; Georgescu, A M; Degeratu, M; Haşegan, L; Hlevca, D

    2012-01-01

    The power supplied by a turbine with the rotor placed in a free stream flow may be increased by augmenting the velocity in the rotor area. The energy of the free flow is dispersed and it may be concentrated by placing a profiled structure around the bare turbine in order to concentrate more energy in the rotor zone. At the Aerodynamic and Wind Engineering Laboratory (LAIV) of the Technical University of Civil Engineering of Bucharest (UTCB) it was developed a concentrating housing to be used for hydro or aeolian horizontal axis wind turbines, in order to increase the available energy in the active section of turbine rotor. The shape of the concentrating housing results by superposing several aero/hydro dynamic effects, the most important being the one generated by the passive flow control devices that were included in the housing structure. Those concentrating housings may be also adapted for hydro or aeolian turbines with vertical axis. The present paper details the numerical research effectuated at the LAIV to determine the performances of a vertical axis marine turbine equipped with such a concentrating device, in order to increase the energy quantity extracted from the main flow. The turbine is a Darrieus type one with three vertical straight blades, symmetric with respect to the axis of rotation, generated using a NACA4518 airfoil. The global performances of the turbine equipped with the concentrating housing were compared to the same characteristics of the bare turbine. In order to validate the numerical approach used in this paper, test cases from the literature resulting from experimental and numerical simulations for similar situations, were used.

  8. A trench study to assess transfer of pesticides in subsurface lateral flow for a soil with contrasting texture on a sloping vineyard in Beaujolais.

    Science.gov (United States)

    Peyrard, X; Liger, L; Guillemain, C; Gouy, V

    2016-01-01

    Subsurface lateral flow in both texture-contrast soils and catchments with shallow bedrock is suspected to be a non-point source of contamination of watercourses by pesticides used in agriculture. As a case study, the north of the Beaujolais region (eastern France) provides a favorable environment for such contamination due to its agro-pedo-climatic conditions. Environments seen in the Beaujolais region include intense viticulture, permeable and shallow soils, steep hillslopes, and storms that occur during the periods of pesticide application. Watercourse contamination by pesticides has been widely observed in this region, and offsite pesticide transport by subsurface lateral flow is suspected to be involved in diffuse and chronic presence of pesticides in surface water. In order to confirm and quantify the potential role of such processes in pesticide transfer, an automated trench system has been designed. The trench was set up on a steep farmed hillslope in a texture-contrast soil. It was equipped with a tipping bucket flow meter and an automatic sampler to monitor pesticide concentrations in lateral flow at fine resolution, by means of a flow-dependent sampling strategy. Four pesticides currently used in vine growing were studied to provide a range of mobility properties: one insecticide (chlorpyrifos-methyl) and three fungicides (spiroxamine, tebuconazole, and dimethomorph). With this system, it was possible to study pesticide concentration dynamics in the subsurface lateral flow, generated by substantial rainfall events following pesticide applications. The experimental design ascertained to be a suitable method in which to monitor subsurface lateral flow and related transfer of pesticides.

  9. Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

    Directory of Open Access Journals (Sweden)

    Spiliopoulos Sotirios

    2012-11-01

    Full Text Available Abstract Background Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. Clinical case We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an end-stage heart failure on the grounds of a dilated cardiomyopathy. Real-time pump blood flow was directly measured by an ultrasonic flow probe placed around the outflow graft. Diagnosis The progressive decline of real time flow and the loss of pulsatility were associated with an increase of central venous pressure, inotropic therapy and progressive renal failure suggesting the presence of an acute right heart failure. Diagnosis was validated by echocardiography and thermodilution measurements. Treatment Temporary mechanical circulatory support of the right ventricle was successfully performed. Real time flow measurement proved to be a useful tool for the diagnosis and ultimately for the management of right heart failure including the weaning from extracorporeal membrane oxygenation.

  10. The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device.

    Science.gov (United States)

    Schönberger, Markus; Deutsch, Steven; Manning, Keefe B

    2012-01-01

    Ventricular assist devices are a commonly used heart failure therapy for adult patients as bridge-to-transplant or bridge-to-recovery tools. The application of adult ventricular assist devices in pediatric patients has led to increased thrombotic events. Therefore, we have been developing a pediatric ventricular assist device (PVAD), the Penn State 12 cc PVAD. It is designed for patients with a body weight of 5-15 kg and has a stroke volume of 12 cc. Clot formation is the major concern. It is correlated to the coagulability of blood, the blood contacting materials and the fluid dynamics within the system. The intent is for the PVAD to be a long term therapy. Therefore, the system may be oriented in different positions according to the patient's behavior. This study evaluates for the first time the impact of position on the flow patterns within the Penn State 12 cc PVAD, which may help to improve the PVAD design concerning chamber and ports geometries. The fluid dynamics are visualized by particle image velocimetry. The evaluation is based on inlet jet behavior and calculated wall shear rates. Vertical and horizontal model orientations are compared, both with a beat rate of 75, outlet pressures of 90/60 mm Hg and a flow rate of 1.3 l/min. The results show a significant change of the inlet jet behavior and the development of a rotational flow pattern. Vertically, the inlet jet is strong along the wall. It initiates a rotational flow pattern with a wandering axis of rotation. In contrast, the horizontal model orientation results show a weaker inlet jet along the wall with a nearly constant center of rotation location, which can be correlated to a higher risk of thrombotic events. In addition, high speed videography illustrates differences in the diaphragm motion during diastole. Diaphragm opening trajectories measurements determine no significant impact of the density of the blood analog fluids. Hence, the results correlate to human blood.

  11. Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system.

    Science.gov (United States)

    Saleh, Mahdi; Spence, John Nathan; Nayak, Sanjeev; Pearce, Gillian; Tennuci, Christopher; Roffe, Christine

    2012-01-01

    There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. Thrombi made of lamb's blood were placed into a pulsatile flow system perfused with Hartmann's solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted.

  12. Sampling device for withdrawing a representative sample from single and multi-phase flows

    Science.gov (United States)

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  13. A lateral flow biosensor for detection of single nucleotide polymorphism by circular strand displacement reaction.

    Science.gov (United States)

    Xiao, Zhuo; Lie, Puchang; Fang, Zhiyuan; Yu, Luxin; Chen, Junhua; Liu, Jie; Ge, Chenchen; Zhou, Xuemeng; Zeng, Lingwen

    2012-09-04

    A lateral flow biosensor for detection of single nucleotide polymorphism based on circular strand displacement reaction (CSDPR) has been developed. Taking advantage of high fidelity of T4 DNA ligase, signal amplification by CSDPR, and the optical properties of gold nanoparticles, this assay has reached a detection limit of 0.01 fM.

  14. Controllable Microdroplet Splitting via Additional Lateral Flow and its Application in Rapid Synthesis of Multi-scale Microspheres

    KAUST Repository

    Zhou, Bingpu; Wang, Cong; Xiao, Xiao; Hui, Yu Sanna; Cao, Yulin; Wen, Weijia

    2015-01-01

    In this paper, we demonstrate that controllable microdroplet splitting could be obtained via additional lateral flow with simplicity and high controllability. The volume ratio of the two splitting products can be flexibly regulated by adjusting

  15. Flow Visualization of Three-Dimensionality Inside the 12 cc Penn State Pulsatile Pediatric Ventricular Assist Device

    OpenAIRE

    Roszelle, Breigh N.; Deutsch, Steven; Manning, Keefe B.

    2010-01-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV...

  16. A Novel Counter Sheet-flow Sandwich Cell Culture Device for Mammalian Cell Growth in Space

    Science.gov (United States)

    Sun, Shujin; Gao, Yuxin; Shu, Nanjiang; Tang, Zemei; Tao, Zulai; Long, Mian

    2008-08-01

    Cell culture and growth in space is crucial to understand the cellular responses under microgravity. The effects of microgravity were coupled with such environment restrictions as medium perfusion, in which the underlying mechanism has been poorly understood. In the present work, a customer-made counter sheet-flow sandwich cell culture device was developed upon a biomechanical concept from fish gill breathing. The sandwich culture unit consists of two side chambers where the medium flow is counter-directional, a central chamber where the cells are cultured, and two porous polycarbonate membranes between side and central chambers. Flow dynamics analysis revealed the symmetrical velocity profile and uniform low shear rate distribution of flowing medium inside the central culture chamber, which promotes sufficient mass transport and nutrient supply for mammalian cell growth. An on-orbit experiment performed on a recovery satellite was used to validate the availability of the device.

  17. Immunochromatographic lateral flow strip for on-site detection of bisphenol A

    International Nuclear Information System (INIS)

    Mei, Z.; Deng, Y.; Zhong, Y.; Wu, J.; Yang, H.; Wang, Z.; Zheng, L.; Chen, W.; Chu, H.; Xue, F.

    2013-01-01

    We have developed a lateral flow assay (LFA) for the detection of bisphenol A (BPA) in water samples. Antibody against BPA was labeled with gold nanoparticles, and these conjugates were used as the recognition probes for the construction of an LFA strip. The diameter of the gold nanoparticles, the amount of antibody, the pH of the buffer, and the categories of the conjugation pad were optimized. The resulting method has a (visual) detection limit of 5 ppb, and of 0.92 ppb if used in combination with professional software. This LFA displays excellent specificity and was applied to spiked water samples with satisfactory results. (author)

  18. A microfluidic device for study of the effect of tumor vascular structures on the flow field and HepG2 cellular flow behaviors.

    Science.gov (United States)

    Ke, Ming; Cai, Shaoxi; Zou, Misha; Zhao, Yi; Li, Bo; Chen, Sijia; Chen, Longcong

    2018-01-29

    To build a microfluidic device with various morphological features of the tumor vasculature for study of the effects of tumor vascular structures on the flow field and tumor cellular flow behaviors. The designed microfluidic device was able to approximatively simulate the in vivo structures of tumor vessels and the flow within it. In this models, the influences of the angle of bifurcation, the number of branches, and the narrow channels on the flow field and the influence of vorticity on the retention of HepG2 cells were significant. Additionally, shear stress below physiological conditions of blood circulation has considerable effect on the formation of the lumen-like structures (LLSs) of HepG2 cells. These results can provide some data and reference in the understanding of the interaction between hemorheological properties and tumor vascular structures in solid tumors. Copyright © 2018. Published by Elsevier Inc.

  19. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network.

    Science.gov (United States)

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network including a rat, a reservoir, a pinch valve, and a peristaltic pump. To demonstrate the proposed method, a twin-shaped microfluidic device, which is composed of two half-circular chambers, two side channels with multiple indicating channels, and one bridge channel, was carefully designed. Based on the microfluidic device, three sequential flow controls were applied to identify viscosity and flow rate of blood, with label-free and sensorless detection. The half-circular chamber was employed to achieve mechanical membrane compliance for flow stabilization in the microfluidic device. To quantify the effect of flow stabilization on flow fluctuations, a formula of pulsation index (PI) was analytically derived using a discrete fluidic circuit model. Using the PI formula, the time constant contributed by the half-circular chamber is estimated to be 8 s. Furthermore, flow fluctuations resulting from the peristaltic pumps are completely removed, especially under periodic flow conditions within short periods (T viscosity with respect to varying flow rate conditions [(a) known blood flow rate via a syringe pump, (b) unknown blood flow rate via a peristaltic pump]. As a result, the flow rate and viscosity of blood can be simultaneously measured with satisfactory accuracy. In addition, the proposed method was successfully applied to identify the viscosity of rat blood, which circulates in a complex fluidic network. These observations confirm that the proposed method can be used for

  20. The effect of gas and fluid flows on nonlinear lateral vibrations of rotating drill strings

    Science.gov (United States)

    Khajiyeva, Lelya; Kudaibergenov, Askar; Kudaibergenov, Askat

    2018-06-01

    In this work we develop nonlinear mathematical models describing coupled lateral vibrations of a rotating drill string under the effect of external supersonic gas and internal fluid flows. An axial compressive load and a torque also affect the drill string. The mathematical models are derived by the use of Novozhilov's nonlinear theory of elasticity with implementation of Hamilton's variation principle. Expressions for the gas flow pressure are determined according to the piston theory. The fluid flow is considered as added mass inside the curved tube of the drill string. Using an algorithm developed in the Mathematica computation program on the basis of the Galerkin approach and the stiffness switching method the numerical solution of the obtained approximate differential equations is found. Influences of the external loads, drill string angular speed of rotation, parameters of the gas and fluid flows on the drill string vibrations are shown.

  1. Droplet trapping and fast acoustic release in a multi-height device with steady-state flow.

    Science.gov (United States)

    Rambach, Richard W; Linder, Kevin; Heymann, Michael; Franke, Thomas

    2017-10-11

    We demonstrate a novel multilayer polydimethylsiloxane (PDMS) device for selective storage and release of single emulsion droplets. Drops are captured in a microchannel cavity and can be released on-demand through a triggered surface acoustic wave pulse. The surface acoustic wave (SAW) is excited by a tapered interdigital transducer (TIDT) deposited on a piezoelectric lithium niobate (LiNbO 3 ) substrate and inverts the pressure difference across the cavity trap to push a drop out of the trap and back into the main flow channel. Droplet capture and release does not require a flow rate change, flow interruption, flow inversion or valve action and can be achieved in as fast as 20 ms. This allows both on-demand droplet capture for analysis and monitoring over arbitrary time scales, and continuous device operation with a high droplet rate of 620 drops per s. We hence decouple long-term droplet interrogation from other operations on the chip. This will ease integration with other microfluidic droplet operations and functional components.

  2. Integrated Photoelectrochemical Solar Energy Conversion and Organic Redox Flow Battery Devices

    KAUST Repository

    Li, Wenjie

    2016-09-21

    Building on regenerative photoelectrochemical solar cells and emerging electrochemical redox flow batteries (RFBs), more efficient, scalable, compact, and cost-effective hybrid energy conversion and storage devices could be realized. An integrated photoelectrochemical solar energy conversion and electrochemical storage device is developed by integrating regenerative silicon solar cells and 9,10-anthraquinone-2,7-disulfonic acid (AQDS)/1,2-benzoquinone-3,5-disulfonic acid (BQDS) RFBs. The device can be directly charged by solar light without external bias, and discharged like normal RFBs with an energy storage density of 1.15 Wh L−1 and a solar-to-output electricity efficiency (SOEE) of 1.7 % over many cycles. The concept exploits a previously undeveloped design connecting two major energy technologies and promises a general approach for storing solar energy electrochemically with high theoretical storage capacity and efficiency.

  3. Relationship between cerebral blood flow and later cognitive decline in hypertensive patients with cerebral small vessel disease

    International Nuclear Information System (INIS)

    Kitagawa, Kazuo; Oku, Naohiko; Yagita, Yoshiki; Sakaguchi, Manabu; Sakoda, Saburo; Kimura, Yasuyuku; Hatazawa, Jun

    2009-01-01

    Vascular risk factors are thought to be important for dementia. However, there is little evidence for a prospective association between cerebral blood flow and the risk of cognitive decline. Twenty-seven cognitively intact hypertensive patients aged 55 years and older with lacunar infarction or white matter lesions in magnetic resonance imaging (MRI) underwent positron emission tomography (PET) to measure cerebral blood flow (CBF) and cerebral vascular reactivity (CVR). Cognitive function was assessed at baseline and 3 years later with the mini-mental state examination (MMSE). Patients whose MMSE score fell by more than three points were classified as having cognitive decline. Six patients showed cognitive decline. Baseline CBF in these patients was significantly lower than that of the 21 patients without cognitive decline (31.2±2.4 vs. 42.6±5.9 ml per 100 gmin -1 , respectively; P<0.001). A moderate linear association was found between CBF and change in MMSE score over a 3-year period (r=0.59, P=0.001), not between CBF and baseline MMSE score. In contrast, no association between CVR and later cognitive decline was found. This study suggests that cerebral hypoperfusion is associated with later cognitive decline. (author)

  4. Local spin valve effect in lateral (Ga,MnAs/GaAs spin Esaki diode devices

    Directory of Open Access Journals (Sweden)

    M. Ciorga

    2011-06-01

    Full Text Available We report here on a local spin valve effect observed unambiguously in lateral all-semiconductor all-electrical spin injection devices, employing p+ −(Ga,MnAs/n+ −GaAs Esaki diode structures as spin aligning contacts. We discuss the observed local spin-valve signal as a result of the interplay between spin-transport-related contribution and the tunneling anisotropic magnetoresistance of the magnetic contacts. The magnitude of the spin-related magnetoresistance change is equal to 30 Ω which is twice the magnitude of the measured non-local signal.

  5. Phase Resolved Angular Velocity Control of Cross Flow Turbines

    Science.gov (United States)

    Strom, Benjamin; Brunton, Steven; Polagye, Brian

    2015-11-01

    Cross flow turbines have a number of operational advantages for the conversion of kinetic energy in marine or fluvial currents, but they are often less efficient than axial flow devices. Here a control scheme is presented in which the angular velocity of a cross flow turbine with two straight blades is prescribed as a function of azimuthal blade position, altering the time-varying effective angle of attack. Flume experiments conducted with a scale model turbine show approximately an 80% increase in turbine efficiency versus optimal constant angular velocity and constant resistive torque control schemes. Torque, drag, and lateral forces on one- and two-bladed turbines are analyzed and interpreted with bubble flow visualization to develop a simple model that describes the hydrodynamics responsible for the observed increase in mean efficiency. Challenges associated with implementing this control scheme on commercial-scale devices are discussed. If solutions are found, the performance increase presented here may impact the future development of cross flow turbines.

  6. Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

    Energy Technology Data Exchange (ETDEWEB)

    Small IV, W; Gjersing, E; Herberg, J L; Wilson, T S; Maitland, D J

    2008-10-29

    Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

  7. Immunochromatographic Brucella-specific immunoglobulin M and G lateral flow assays for rapid serodiagnosis of human brucellosis

    NARCIS (Netherlands)

    Smits, Henk L.; Abdoel, Theresia H.; Solera, Javier; Clavijo, Encarnacion; Diaz, Ramon

    2003-01-01

    To fulfill the need for a simple and rapid diagnostic test for human brucellosis, we used the immunochromatographic lateral flow assay format to develop two assays, one for the detection of Brucella-specific immunoglobulin M (IgM) antibodies and one for the detection of Brucella-specific IgG

  8. Device for determining element contents of lignite mass flows by activation analysis

    International Nuclear Information System (INIS)

    Goeldner, R.; Maul, E.; Rose, W.; Wagner, D.

    1987-01-01

    A simple device is presented, apt for continuous operation, to determine the element contents of bulk goods of flowable materials with a suitable granularity, in particular of lignite mass flows to assess the coal quality. Several kilograms of samples can be reproducibly dosed and homogeneously activated by a device consisting of a shielding container with activation chamber and radiation source, a measuring unit with detectors, and a source container, and characterized by a blade wheel in the activation chamber which causes the dosing and homogeneous activation of the sample

  9. Experimental investigation of different fluid flow profiles in a rotary multi-bed active magnetic regenerator device

    DEFF Research Database (Denmark)

    Fortkamp, F. P.; Eriksen, D.; Engelbrecht, K.

    2018-01-01

    A rotary multi-bed active magnetic regenerator (AMR) device was modified to allow testing different fluid flow waveforms, with different blow fractions (i.e. the fraction of the AMR cycle when there is fluid flow in the regenerators). The different values of blow fraction were generated using dif.......1% was obtained for the largest blow fraction tested (80%). Designs for magnetic refrigerators where the fluid flow waveform can change during operation are also discussed in this paper.......A rotary multi-bed active magnetic regenerator (AMR) device was modified to allow testing different fluid flow waveforms, with different blow fractions (i.e. the fraction of the AMR cycle when there is fluid flow in the regenerators). The different values of blow fraction were generated using...... different cam rings that actuate the poppet valves at the inlet and outlet of the regenerators, controlling how long the valves stay open and the number of valves open at the same time. Results showed that smaller blow fractions yield higher values of temperature span for fixed flow rate and cooling...

  10. Modelling lateral entrapment of suspended sediment in estuaries : The role of spatial lags in settling and M4 tidal flow

    NARCIS (Netherlands)

    Yang, Zhongyong; de Swart, Huib E.; Cheng, Heqin; Jiang, Chenjuan; Valle-Levinson, Arnoldo

    2014-01-01

    The effect of the joint action of M2 and M4 tidal flow, residual flow and spatial settling lag on the lateral entrapment of sediment is examined in tidally dominated estuaries with an idealized model that assumes along-estuary uniform conditions. Approximate solutions are obtained for arbitrary

  11. Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device

    DEFF Research Database (Denmark)

    Miller, M.R.; Atkins, P.R.; Pedersen, O.F.

    2003-01-01

    Methods: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid.......1) and 257 (39.2), respectively, and at ≈200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. Conclusions: An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses...

  12. Isothermal Recombinase Polymerase amplification (RPA) of Schistosoma haematobium DNA and oligochromatographic lateral flow detection.

    Science.gov (United States)

    Rosser, A; Rollinson, D; Forrest, M; Webster, B L

    2015-09-04

    Accurate diagnosis of urogenital schistosomiasis is vital for surveillance/control programs. Amplification of schistosome DNA in urine by PCR is sensitive and specific but requires infrastructure, financial resources and skilled personnel, often not available in endemic areas. Recombinase Polymerase Amplification (RPA) is an isothermal DNA amplification/detection technology that is simple, rapid, portable and needs few resources. Here a Schistosoma haematobium RPA assay was developed and adapted so that DNA amplicons could be detected using oligochromatographic Lateral Flow (LF) strips. The assay successfully amplified S. haematobium DNA at 30-45 °C in 10 mins and was sensitive to a lower limit of 100 fg of DNA. The assay was also successful with the addition of crude urine, up to 5% of the total reaction volume. Cross amplification occurred with other schistosome species but not with other common urine microorganisms. The LF-RPA assay developed here can amplify and detect low levels of S. haematobium DNA. Reactions are rapid, require low temperatures and positive reactions are interpreted using lateral flow strips, reducing the need for infrastructure and resources. This together with an ability to withstand inhibitors within urine makes RPA a promising technology for further development as a molecular diagnostic tool for urogenital schistosomiasis.

  13. Enhancement of arterial pressure pulsatility by controlling continuous-flow left ventricular assist device flow rate in mock circulatory system

    NARCIS (Netherlands)

    Bozkurt, S.; van de Vosse, F.N.; Rutten, M.C.M.

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase

  14. In vitro and in vivo evaluation of a new large animal spirometry device using mainstream CO2 flow sensors.

    Science.gov (United States)

    Ambrisko, T D; Lammer, V; Schramel, J P; Moens, Y P S

    2014-07-01

    A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. In vitro experiment and crossover study using anaesthetised horses. A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720 l/min). One sensor was connected to a spirometry monitor for in vitro volume (3, 5 and 7 l) measurements. These measurements were compared with a reference method. Five anaesthetised horses were used for tidal volume (VT) measurements using the FPD and a horse-lite sensor (reference method). Bland-Altman analysis, ANOVA and linear regression analysis were used for data analysis. Pressure differences across each sensor were similar suggesting equal flow partitioning. The resistance of the device increased with flow (range: 0.3-1.5 cmH2 O s/l) and was higher than that of the horse-lite. The limits of agreement for volume measurements were within -1 and 2% in vitro and -12 and 0% in vivo. Nine of 147 VT measurements in horses were outside of the ± 10% limits of acceptance but most of these erroneous measurements occurred with VTs lower than 4 l. The determined correction factor for volume measurements was 3.97 ± 0.03. The limits of agreement for volume measurements by the new device were within ± 10% using clinically relevant range of volumes. The new spirometry device can be recommended for measurement of VT in adult Warmblood horses. © 2013 EVJ Ltd.

  15. Simultaneous ultrasound and photoacoustics based flow cytometry

    Science.gov (United States)

    Gnyawali, Vaskar; Strohm, Eric M.; Tsai, Scott S. H.; Kolios, Michael C.

    2018-04-01

    We have developed a flow cytometer based on simultaneous detection of ultrasound and photoacoustic waves from individual particles/cells flowing in a microfluidic channel. Our polydimethylsiloxane (PDMS) based hydrodynamic 3-dimensional (3D) flow-focusing microfluidic device contains a cross-junction channel, a micro-needle (ID 100 μm and OD 200 μm) insert, and a 3D printed frame to hold and align a high frequency (center frequency 375 MHz) ultrasound transducer. The focused flow passes through a narrow focal zone with lateral and axial focal lengths of 6-8 μm and 15-20 μm, respectively. Both the lateral and axial alignments are achieved by screwing the transducer to the frame onto the PDMS device. Individual particles pass through an interrogation zone in the microfluidic channel with a collinearly aligned ultrasound transducer and a focused 532 nm wavelength laser beam. The particles are simultaneously insonified by high-frequency ultrasound and irradiated by a laser beam. The ultrasound backscatter and laser generated photoacoustic waves are detected for each passing particle. The backscattered ultrasound and photoacoustic signal are strongly dependent on the size, morphology, mechanical properties, and material properties of the flowing particles; these parameters can be extracted by analyzing unique features in the power spectrum of the signals. Frequencies less than 100 MHz do not have these unique spectral signatures. We show that we can reliably distinguish between different particles in a sample using the acoustic-based flow cytometer. This technique, when extended to biomedical applications, allows us to rapidly analyze the spectral signatures from individual single cells of a large cell population, with applications towards label-free detection and characterization of healthy and diseased cells.

  16. Underwater tracking of a moving dipole source using an artificial lateral line: algorithm and experimental validation with ionic polymer–metal composite flow sensors

    International Nuclear Information System (INIS)

    Abdulsadda, Ahmad T; Tan, Xiaobo

    2013-01-01

    Motivated by the lateral line system of fish, arrays of flow sensors have been proposed as a new sensing modality for underwater robots. Existing studies on such artificial lateral lines (ALLs) have been mostly focused on the localization of a fixed underwater vibrating sphere (dipole source). In this paper we examine the problem of tracking a moving dipole source using an ALL system. Based on an analytical model for the moving dipole-generated flow field, we formulate a nonlinear estimation problem that aims to minimize the error between the measured and model-predicted magnitudes of flow velocities at the sensor sites, which is subsequently solved with the Gauss–Newton scheme. A sliding discrete Fourier transform (SDFT) algorithm is proposed to efficiently compute the evolving signal magnitudes based on the flow velocity measurements. Simulation indicates that it is adequate and more computationally efficient to use only the signal magnitudes corresponding to the dipole vibration frequency. Finally, experiments conducted with an artificial lateral line consisting of six ionic polymer–metal composite (IPMC) flow sensors demonstrate that the proposed scheme is able to simultaneously locate the moving dipole and estimate its vibration amplitude and traveling speed with small errors. (paper)

  17. -MoS2 Lateral Heterojunctions

    KAUST Repository

    Li, Ming-yang

    2018-02-28

    2D layered heterostructures have attracted intensive interests due to their unique optical, transport, and interfacial properties. The laterally stitched heterojunction based on dissimilar 2D transition metal dichalcogenides forms an intrinsic p–n junction without the necessity of applying an external voltage. However, no scalable processes are reported to construct the devices with such lateral heterostructures. Here, a scalable strategy, two-step and location-selective chemical vapor deposition, is reported to synthesize self-aligned WSe2–MoS2 monolayer lateral heterojunction arrays and demonstrates their light-emitting devices. The proposed fabrication process enables the growth of high-quality interfaces and the first successful observation of electroluminescence at the WSe2–MoS2 lateral heterojunction. The electroluminescence study has confirmed the type-I alignment at the interface rather than commonly believed type-II alignment. This self-aligned growth process paves the way for constructing various 2D lateral heterostructures in a scalable manner, practically important for integrated 2D circuit applications.

  18. Integrated Photoelectrochemical Solar Energy Conversion and Organic Redox Flow Battery Devices.

    Science.gov (United States)

    Li, Wenjie; Fu, Hui-Chun; Li, Linsen; Cabán-Acevedo, Miguel; He, Jr-Hau; Jin, Song

    2016-10-10

    Building on regenerative photoelectrochemical solar cells and emerging electrochemical redox flow batteries (RFBs), more efficient, scalable, compact, and cost-effective hybrid energy conversion and storage devices could be realized. An integrated photoelectrochemical solar energy conversion and electrochemical storage device is developed by integrating regenerative silicon solar cells and 9,10-anthraquinone-2,7-disulfonic acid (AQDS)/1,2-benzoquinone-3,5-disulfonic acid (BQDS) RFBs. The device can be directly charged by solar light without external bias, and discharged like normal RFBs with an energy storage density of 1.15 Wh L -1 and a solar-to-output electricity efficiency (SOEE) of 1.7 % over many cycles. The concept exploits a previously undeveloped design connecting two major energy technologies and promises a general approach for storing solar energy electrochemically with high theoretical storage capacity and efficiency. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Free flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes

    NARCIS (Netherlands)

    Kohlheyer, D.; Besselink, G.A.J.; Schlautmann, Stefan; Schasfoort, Richardus B.M.

    2006-01-01

    This paper describes a microfabricated free-flow electrophoresis device with integrated ion permeable membranes. In order to obtain continuous lanes of separated components an electrical field is applied perpendicular to the sample flow direction. This sample stream is sandwiched between two sheath

  20. Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anuradha Sridhar

    2012-01-01

    Full Text Available We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm ′Type A′ patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.

  1. Non-Invasive Mapping of Intraventricular Flow Patterns in Patients Treated with Left Ventricular Assist Devices

    Science.gov (United States)

    Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.

    2017-11-01

    In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.

  2. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan

    NARCIS (Netherlands)

    Mizanbayeva, Sulushash; Smits, Henk L.; Zhalilova, Katya; Abdoel, Theresia H.; Kozakov, Stanislaw; Ospanov, Kenes S.; Elzer, Philip H.; Douglas, James T.

    2009-01-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high

  3. Device for measurement of gas mass flow. Einrichtung zur Gasmassenstrommessung

    Energy Technology Data Exchange (ETDEWEB)

    Sass, W

    1989-09-28

    The invention is concerned with a device for the measurement of gas mass flow, particularly measuring air mass flow for vehicles with internal combustion engines, with a measurement bridge, in one branch of which a gas flow resistance, particularly a hot film sensor, with gas flowing round it, is connected in series with a measurement resistance and in another branch of which a compensation resistance measuring the gas temperature is connected in series with a fixed resistor, where the bridge differential voltage is measured in the zero branch of the measuring bridge and a control parameter is produced from this, in order to control a transistor valve situated in the bridge supply path of a DC voltage source via its control electrode until the bridge is balanced, and where the voltage at the measurement resistance after the bridge is balanced is used as a measure of the gas mass flow. In order to obtain exact results of measurement in spite of relatively high interference noise from the cables, it is proposed that an increased supply DC voltage appreciably decreasing the occurring interference noise from the cables should be produced from a small DC voltage and that the output of the DC/DC voltage converter should be connected to the control electrode of the transistor valve, so that the control parameter for the control electrode is derived from the raised DC supply voltage through reducers depending on the gas flow.

  4. Integration of lateral flow and micro array technologies for multiplex immunoassay: application to the determination of drugs of abuse

    International Nuclear Information System (INIS)

    Taranova, Nadezhda A.; Byzova, Nadezhda A.; Zaiko, Viktoria V.; Starovoitova, Tatiana A.; Vengerov, Yury Yu.; Zherdev, Anatoly V.; Dzantiev, Boris B.

    2013-01-01

    We report on a lateral flow micro array that combines multi-spot immunochip technology and immunochromatography. It can serve as a tool for the simultaneous detection of multiple analytes. The test zone of the nitrocellulose support comprises a micro array spotted with up to 32 antigens that can capture labeled gold-antibodies after lateral flow. The detection limits and detectable concentration ranges of the assay were characterized. The method was applied to the determination of drugs of abuse (and their metabolites) in urine, specifically of morphine, amphetamine, methamphetamine, and benzoylecgonine. The assay format is rapid (10 min), and has both a low relative standard deviation ( -1 for drugs of abuse) are comparable to those of conventional single-analyte strip methods. (author)

  5. Lateral topological crystalline insulator heterostructure

    Science.gov (United States)

    Sun, Qilong; Dai, Ying; Niu, Chengwang; Ma, Yandong; Wei, Wei; Yu, Lin; Huang, Baibiao

    2017-06-01

    The emergence of lateral heterostructures fabricated by two-dimensional building blocks brings many exciting realms in material science and device physics. Enriching available nanomaterials for creating such heterostructures and enabling the underlying new physics is highly coveted for the integration of next-generation devices. Here, we report a breakthrough in lateral heterostructure based on the monolayer square transition-metal dichalcogenides MX2 (M  =  W, X  =  S/Se) modules. Our results reveal that the MX2 lateral heterostructure (1S-MX2 LHS) can possess excellent thermal and dynamical stability. Remarkably, the highly desired two-dimensional topological crystalline insulator phase is confirmed by the calculated mirror Chern number {{n}\\text{M}}=-1 . A nontrivial band gap of 65 meV is obtained with SOC, indicating the potential for room-temperature observation and applications. The topologically protected edge states emerge at the edges of two different nanoribbons between the bulk band gap, which is consistent with the mirror Chern number. In addition, a strain-induced topological phase transition in 1S-MX2 LHS is also revealed, endowing the potential utilities in electronics and spintronics. Our predictions not only introduce new member and vitality into the studies of lateral heterostructures, but also highlight the promise of lateral heterostructure as appealing topological crystalline insulator platforms with excellent stability for future devices.

  6. A novel multi-walled carbon nanotube-based antibody conjugate for quantitative and semi-quantitative lateral flow assays.

    Science.gov (United States)

    Sun, Wenjuan; Hu, Xiaolong; Liu, Jia; Zhang, Yurong; Lu, Jianzhong; Zeng, Libo

    2017-10-01

    In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.

  7. Heat-flow and lateral seismic-velocity heterogeneities near Deep Sea Drilling Project-Ocean Drilling Program Site 504

    Science.gov (United States)

    Lowell, Robert P.; Stephen, Ralph A.

    1991-11-01

    Both conductive heat-flow and seismic-velocity data contain information relating to the permeability of the oceanic crust. Deep Sea Drilling Project-Ocean Drilling Program Site 504 is the only place where both detailed heat-flow and seismic-velocity field studies have been conducted at the same scale. In this paper we examine the correlation between heat flow and lateral heterogeneities in seismic velocity near Site 504. Observed heterogeneities in seismic velocity, which are thought to be related to variations in crack density in the upper 500 m of the basaltic crust, show little correlation with the heat-flow pattern. This lack of correlation highlights some of the current difficulties in using seismic-velocity data to infer details of spatial variations in permeability that are significant in controlling hydrothermal circulation.

  8. Rapid and sensitive detection of novel avian-origin influenza A (H7N9 virus by reverse transcription loop-mediated isothermal amplification combined with a lateral-flow device.

    Directory of Open Access Journals (Sweden)

    Yiyue Ge

    Full Text Available A severe disease in humans caused by a novel avian-origin influenza A (H7N9 virus emerged in China recently, which has caused at least 128 cases and 26 deaths. Rapid detection of the novel H7N9 virus is urgently needed to differentiate the disease from other infections, and to facilitate infection control as well as epidemiologic investigations. In this study, a reverse transcription loop-mediated isothermal amplification combined with a lateral flow device (RT-LAMP-LFD assay to rapidly detect H7N9 virus was developed and evaluated. The RT-LAMP primers were designed to target the haemagglutinin (HA and neuraminidase (NA genes of H7N9 virus. Results of 10-fold dilution series assays showed that analysis of RT-LAMP products by the LFD method was as sensitive as real-time turbidity detection, and that the analytic sensitivities of the HA and NA RT-LAMP assays were both 10 copies of synthetic RNA. Furthermore, both the assays showed 100% clinical specificity for identification of H7N9 virus. The performance characteristics of the RT-LAMP-LFD assay were evaluated with 80 clinical specimens collected from suspected H7N9 patients. The NA RT-LAMP-LFD assay was more sensitive than real time RT-PCR assay. Compared with a combination of virus culture and real-time RT-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value of the RT-LAMP-LFD assay were all 100%. Overall, The RT-LAMP-LFD assay established in this study can be used as a reliable method for early diagnosis of the avian-origin influenza A (H7N9 virus infection.

  9. Counterforce Orthosis In The Management Of Lateral Epicondylitis.

    Science.gov (United States)

    Vellilappilly, Daison Varghese; Rai, Heroor Ravindranath; Varghese, Jaison; Renjith, Vishnu

    2017-01-01

    Lateral Epicondylitis (LE), is a condition characterized by the pain and tenderness over the lateral epicondyle of the humerus. LE is commonly seen among people who are involved in sports such as tennis and golf. Any activity that repeatedly overstrains the extensor carpi radialis brevis tendon can lead to LE. The management of lateral epicondylitis generally involves the use of counterforce orthosis. The aim of this review is to summarize the evidence regarding the effectiveness of counterforce orthoses on the clinical outcomes of patients with lateral epicondylitis. The PubMed, Ovid, and ProQuest databases were searched for potential studies which explored the use of counterforce orthosis in the management of lateral epicondylitis. To have a better understanding of the effectiveness of various types of orthoses, the review is organized into four sections. The first section explores the use of a single orthotic device, the second section focuses on the combined use of orthotic devices, the third section explore studies that compared the effect of local steroid injection along with orthosis and the last section narrate the studies that compared various types of orthotic devices. The studies support the use of orthotic devices as a treatment modality for lateral epicondylitis. There is rising evidence which supports the use of a comprehensive approach, (by combining routine physiotherapy with orthotic devices) in the management of LE. Orthosis alone or in combination with routine physical therapy can be considered as an evidence-based treatment strategy for patients with lateral epicondylitis. However, on the basis of the literature review conducted, the authors recommend that further high-quality clinical trials regarding the management of lateral epicondylitis are necessary to strengthen the evidence-based physiotherapy practice.

  10. Detached-Eddy Simulation of a Fluidic Device for a Prediction of Pressure Loss Characteristics in a Low Flow Mode

    International Nuclear Information System (INIS)

    Lim, Sang Gyu; Lee, Suk Ho; Kim, Han Gon

    2010-01-01

    The Advanced Power Reactor 1400(APR1400) adopts a passive flow controller in Safety Injection Tanks (SITs) as one of Advanced Design Features (ADFs). This device, called a 'Fluidic Device (FD)', controls the flow rate of safety injection water in a passive manner. A flow control mechanism varies the flow resistance in the vortex chamber corresponding to the SIT water level hence the flow rate can be adjusted by the specific flow resistance in a specific flow regime. A full-scale test was performed and the test results met the design requirement of APR1400. To enhance the performance of the FD more effectively, a series of CFD analysis were implemented and remedy of design modification was proposed on the basis of a series of CFD analysis. The results of CFD analysis showed that total discharge time of the fluidic device is to be increased by enhancing the K-factor in consequence of changing the control nozzle angle. However, a tendency of a pressure loss was under-estimated as a limitation of turbulence models such as Reynolds Averaged Navier- Stokes (RANS) models compared to the experimental data. This paper shows that pressure loss characteristics of the FD can be predicted using a Detached-Eddy Simulation (DES) turbulence model, which can provide valuable flow characteristics far exceeding RANS simulations

  11. A special device used for measuring waste gas flow rate in the vent channel of Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhang Yingjun; Zong Guifang; Shi Huaming; Yang Huimin; Jiang Yuana.

    1988-01-01

    A special Venturi-Pitot complex device is discribed which is used for measuring waste gas flow rate in the vent channel of Qinshan nuclear power plant. The device is located at the center of the channel. It can produce enlarged differential pressure signal under the condition of low gas velocity. And the flow resistance of this device is negligible. Experiments to determine the ratio of the velocity at the center of the channel to the average velocity were performed on a 1:12 test model. The special device was calibrated in a closed wind tunnel and its discharge coefficient was obtained. The uncertainty is ±3.5% and the nonlinearity is ±1.3%. The enlargement ratio and the discharge coefficient of the device are also deduced analytically on the basis of hydrodynamics theory

  12. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    Science.gov (United States)

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  13. Electromagnetic device for confining a liquid metal and regulating the flow rate

    International Nuclear Information System (INIS)

    Garnier, Marcel; Moreau, R.J.

    1977-01-01

    The description is given of a device for confining a liquid metal jet, characterized in that it comprises in combination, at the jet outlet nozzle, (a) means for producing a high pressure in the jet composed of a coil around the nozzle and located on its outlet, in combination with facilities for passing a high frequency alternating current through the coil and (b) means for suppressing this high pressure. It is stated that this device has many uses, particularly for allowing the use of a relatively large diameter orifice, hence not subject to the risk of clogging, in order to produce a jet with a relatively small diameter. This invention particularly concerns the application of this device for regulating a flow of liquid metal at an outlet orifice located at the lower end of a receptacle containing this liquid metal [fr

  14. Electronic device, system on chip and method for monitoring a data flow

    NARCIS (Netherlands)

    2012-01-01

    An electronic device is provided which comprises a plurality of processing units (IP1-IP6), a network-based inter-connect (N) coupled to the processing units (IP1-IP6) and at least one monitoring unit (P1, P2) for monitoring a data flow of at least one first communication path between the processing

  15. Immediate Flow Disruption as a Prognostic Factor After Flow Diverter Treatment: Long-Term Experience with the Pipeline Embolization Device.

    Science.gov (United States)

    Dodier, Philippe; Frischer, Josa M; Wang, Wei-Te; Auzinger, Thomas; Mallouhi, Ammar; Serles, Wolfgang; Gruber, Andreas; Knosp, Engelbert; Bavinzski, Gerhard

    2018-05-01

    To report long-term results after Pipeline Embolization Device (PED) implantation, characterize complex and standard aneurysms comprehensively, and introduce a modified flow disruption scale. We retrospectively reviewed a consecutive series of 40 patients harboring 59 aneurysms treated with 54 PEDs. Aneurysm complexity was assessed using our proposed classification. Immediate angiographic results were analyzed using previously published grading scales and our novel flow disruption scale. According to our new definition, 46 (78%) aneurysms were classified as complex. Most PED interventions were performed in the paraophthalmic and cavernous internal carotid artery segments. Excellent neurologic outcome (modified Rankin Scale 0 and 1) was observed in 94% of patients. Our data showed low permanent procedure-related mortality (0%) and morbidity (3%) rates. Long-term angiographic follow-up showed complete occlusion in 81% and near-total obliteration in a further 14%. Complete obliteration after deployment of a single PED was achieved in all standard aneurysms with 1-year follow-up. Our new scale was an independent predictor of aneurysm occlusion in a multivariable analysis. All aneurysms with a high flow disruption grade showed complete occlusion at follow-up regardless of PED number or aneurysm complexity. Treatment with the PED should be recognized as a primary management strategy for a highly selected cohort with predominantly complex intracranial aneurysms. We further show that a priori assessment of aneurysm complexity and our new postinterventional angiographic flow disruption scale predict occlusion probability and may help to determine the adequate number of per-aneurysm devices. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  17. Comparison of clinical outcomes using a Piezosurgery device vs. a conventional osteotome for lateral osteotomy in rhinoplasty.

    Science.gov (United States)

    Koc, Bulent; Koc, Eltaf Ayca; Erbek, Selim

    2017-08-01

    Our aim for this study was to evaluate and compare the clinical outcomes in patients who underwent lateral osteotomy with a Piezosurgery device or a conventional osteotome in open-technique rhinoplasty. This cohort trial involved 65 patients (36 women and 29 men; average age: 23.6 ± 5.71 yr) who underwent surgery between May 2015 and January 2016. Piezosurgery was used for lateral osteotomy in 32 patients, whereas 33 patients underwent conventional external osteotomy. These 2 groups were compared for duration of surgery, perioperative bleeding, postoperative edema, ecchymosis, pain, and patient satisfaction on the first and seventh postoperative days. The Piezosurgery group revealed significantly more favorable outcomes in terms of edema, ecchymosis, and hemorrhage on the first day postoperatively (p Piezosurgery group. Hemorrhage was similar in both groups on the seventh postoperative day (p = 0.67). The Piezosurgery group not only experienced less pain on the first postoperative day (p Piezosurgery may be a promising, safe, and effective method for lateral osteotomy, a critical step in rhinoplasty. The time interval necessary for the learning curve is counteracted by the comfort and satisfaction of both patients and surgeons.

  18. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  19. Preliminary validation of direct detection of foot-and-mouth disease virus within clinical samples using reverse transcription loop-mediated isothermal amplification coupled with a simple lateral flow device for detection.

    Directory of Open Access Journals (Sweden)

    Ryan A Waters

    Full Text Available Rapid, field-based diagnostic assays are desirable tools for the control of foot-and-mouth disease (FMD. Current approaches involve either; 1 Detection of FMD virus (FMDV with immuochromatographic antigen lateral flow devices (LFD, which have relatively low analytical sensitivity, or 2 portable RT-qPCR that has high analytical sensitivity but is expensive. Loop-mediated isothermal amplification (LAMP may provide a platform upon which to develop field based assays without these drawbacks. The objective of this study was to modify an FMDV-specific reverse transcription-LAMP (RT-LAMP assay to enable detection of dual-labelled LAMP products with an LFD, and to evaluate simple sample processing protocols without nucleic acid extraction. The limit of detection of this assay was demonstrated to be equivalent to that of a laboratory based real-time RT-qPCR assay and to have a 10,000 fold higher analytical sensitivity than the FMDV-specific antigen LFD currently used in the field. Importantly, this study demonstrated that FMDV RNA could be detected from epithelial suspensions without the need for prior RNA extraction, utilising a rudimentary heat source for amplification. Once optimised, this RT-LAMP-LFD protocol was able to detect multiple serotypes from field epithelial samples, in addition to detecting FMDV in the air surrounding infected cattle, pigs and sheep, including pre-clinical detection. This study describes the development and evaluation of an assay format, which may be used as a future basis for rapid and low cost detection of FMDV. In addition it provides providing "proof of concept" for the future use of LAMP assays to tackle other challenging diagnostic scenarios encompassing veterinary and human health.

  20. Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeriamonocytogenes in food

    NARCIS (Netherlands)

    Blazkova, M.; Koets, M.; Rauch, P.; Amerongen, van A.

    2009-01-01

    We present a new nucleic acid lateral flow immunoassay (NALFIA) for the assessment of listeria contamination. The detection procedure starts with enrichment of sample in Half Fraser broth (24 h). Following isolation of DNA, a duplex PCR is performed with two labelled primer sets, one generic and

  1. Lateral Variability of Lava flow Morphologies in the Deccan Traps Large Igneous Province (India)

    Science.gov (United States)

    Vanderkluysen, L.; Rader, E. L.; Self, S.; Clarke, A. B.; Sheth, H.; Moyer, D. K.

    2016-12-01

    In continental flood basalt provinces (CFBs), lava flow morphologies have traditionally been classified in two distinct groups recognizable in the field, expressing two different modes of lava flow emplacement mechanisms: (a) compound lava flow fields dominated by meter-sized pāhoehoe toes and lobes; and (b) inflated sheet lobes tens to hundreds of meters in width and meters to tens of meters in height. Temporal transitions between these two emplacement styles have been recognized in many mafic large igneous provinces worldwide and seem to be a fundamental feature of CFBs. However, lateral variations in these morphologies remain poorly studied and understood. In the Deccan CFB of India, two principal hypotheses have been proposed to account for possible lateral variations in lava flow facies: that smaller toes and lobes occur in distal regions of flow fields, representing breakouts at the edges of larger inflated lavas; or on the contrary that smaller toes and lobes represent proximal facies. We conducted a field study focusing on two of the Deccan's formations, the Khandala and the Poladpur, located in the middle and upper sections of the province's defined chemostratigraphy. We studied nine sections along a 600 km long E-W transect, with the easternmost sections representing the most distal outcrops, ≥ 500 km away from inferred vents. The Khandala Formation is traditionally described as a sequence of three thick inflated sheet lobes in the well-exposed sections of the western Deccan. However, in the central Deccan, we find the Khandala to be much thicker overall, with half of its thickness dominated by small, meter-sized toes and lobes. Inflated sheet lobes of the Khandala are thinner on average in the central Deccan than further to the east or west. We document this transition as occurring progressively in outcrops only 80 km apart. In the Poladpur, the average thickness of inflated sheet lobes increases in distal outcrops of the eastern Deccan. We interpret

  2. Interaction Between Downwelling Flow and the Laterally-Varying Thickness of the North American Lithosphere Inferred from Seismic Anisotropy

    Science.gov (United States)

    Behn, M. D.; Conrad, C. P.; Silver, P. G.

    2005-12-01

    Shear flow in the asthenosphere tends to align olivine crystals in the direction of shear, producing a seismically anisotropic asthenosphere that can be detected using a number of seismic techniques (e.g., shear-wave splitting (SWS) and surface waves). In the ocean basins, where the asthenosphere has a relatively uniform thickness and lithospheric anisotropy appears to be small, observed azimuthal anisotropy is well fit by asthenospheric shear flow in global flow models driven by a combination of plate motions and mantle density heterogeneity. In contrast, beneath the continents both the lithospheric ceiling and asthenospheric thickness may vary considerably across cratonic regions and ocean-continent boundaries. To examine the influence of a continental lithosphere with variable thickness on predictions of continental seismic anisotropy, we impose lateral variations in lithospheric viscosity in global models of mantle flow driven by plate motions and mantle density heterogeneity. For the North American continent, the Farallon slab descends beneath a deep cratonic root, producing downwelling flow in the upper mantle and convergent flow beneath the cratonic lithosphere. We evaluate both the orientation of the predicted azimuthal anisotropy and the depth dependence of radial anisotropy for this downwelling flow and find that the inclusion of a strong continental root provides an improved fit to observed SWS observations beneath the North American craton. Thus, we hypothesize that at least some continental anisotropy is associated with sub-lithospheric viscous shear, although fossil anisotropy in the lithospheric layer may also contribute significantly. Although we do not observe significant variations in the direction of predicted anisotropy with depth, we do find that the inclusion of deep continental roots pushes the depth of the anisotropy layer deeper into the upper mantle. We test several different models of laterally-varying lithosphere and asthenosphere

  3. Inferring common cognitive mechanisms from brain blood-flow lateralization data: a new methodology for fTCD analysis.

    Science.gov (United States)

    Meyer, Georg F; Spray, Amy; Fairlie, Jo E; Uomini, Natalie T

    2014-01-01

    Current neuroimaging techniques with high spatial resolution constrain participant motion so that many natural tasks cannot be carried out. The aim of this paper is to show how a time-locked correlation-analysis of cerebral blood flow velocity (CBFV) lateralization data, obtained with functional TransCranial Doppler (fTCD) ultrasound, can be used to infer cerebral activation patterns across tasks. In a first experiment we demonstrate that the proposed analysis method results in data that are comparable with the standard Lateralization Index (LI) for within-task comparisons of CBFV patterns, recorded during cued word generation (CWG) at two difficulty levels. In the main experiment we demonstrate that the proposed analysis method shows correlated blood-flow patterns for two different cognitive tasks that are known to draw on common brain areas, CWG, and Music Synthesis. We show that CBFV patterns for Music and CWG are correlated only for participants with prior musical training. CBFV patterns for tasks that draw on distinct brain areas, the Tower of London and CWG, are not correlated. The proposed methodology extends conventional fTCD analysis by including temporal information in the analysis of cerebral blood-flow patterns to provide a robust, non-invasive method to infer whether common brain areas are used in different cognitive tasks. It complements conventional high resolution imaging techniques.

  4. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

    Science.gov (United States)

    Li, Michelle W; Martin, R Scott

    2007-07-01

    Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.

  5. Electromagnetic application device for flow rate/flow speed control

    International Nuclear Information System (INIS)

    Yoshioka, Senji.

    1994-01-01

    Electric current and magnetic field are at first generated in a direction perpendicular to a flow channel of a fluid, and forces generated by electromagnetic interaction of the current and the magnetic field are combined and exerted on the fluid, to control the flow rate and the flow speed thereby decreasing flowing pressure loss. In addition, an electric current generation means and a magnetic field generation means integrated together are disposed to a structural component constituting the flow channel, and they are combined to attain the aimed effect. The current generating means forms a potential difference by supplying electric power to a pair of electrodes as a cathode and an anode by using structures disposed along the channel, to generate an electric field or electric current in a direction perpendicular to the flow channel. The magnetic field generating means forms a counter current (reciprocal current) by using structures disposed along the flow channel, to generate synthesized or emphasized magnetic field. The fluid can be applied with a force in the direction of the flowing direction by the electromagnetic interaction of the electric current and the magnetic field, thereby capable of propelling the fluid. Accordingly, the flowrate/flowing speed can be controlled inside of the flow channel and flowing pressure loss can be decreased. (N.H.)

  6. An experimental study of the flow characteristics of fluidic device in a passive safety injection tank

    International Nuclear Information System (INIS)

    Cho, Seok; Song, Chul Hwa; Won, Suon Yeon; Min, Kyong Ho; Chung, Moon Ki

    1998-01-01

    It is considered to adopt passive safety injection tank (SIT) as a enhanced safety feature in KNGR. Passive SIT employs a vortex chamber as a fluidic device, which control injection flow rate passively by the variation of flow resistance produced by vortex intensity within the vortex chamber. To investigate the flow characteristics of the vortex chamber many tests have been carried out by using small-scale test facility. In this report the effects of geometric parameters of vortex chamber on discharge flow characteristics and the velocity measurement result of flow field, measured by PIV, are presented and discussed. (author). 25 refs., 11 tabs., 31 figs

  7. Humidification performance of two high-flow nasal cannula devices: a bench study.

    Science.gov (United States)

    Chikata, Yusuke; Izawa, Masayo; Okuda, Nao; Itagaki, Taiga; Nakataki, Emiko; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2014-08-01

    Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O2/air blender and a heated humidifier, which was set at 40°C/3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (VT) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min (P 30 mg/L.

  8. Interchangeable opening and closing clapper device notably for ventilation ducts utilizing an aggressive or polluting fluid

    International Nuclear Information System (INIS)

    1980-01-01

    This opening and closing device is of the type which employs a casing inside the duct along the fluid path. It is provided with an opening through which the fluid flows and a joint with a closing clapper controlled from the outside enabling the fluid flow to be regulated. It is characterized by the fact that the casing is provided with a lateral opening with respect to the fluid flow direction, the size of this opening being sufficiently large to allow the assembly with its closing clapper to be introduced and withdrawn [fr

  9. Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

    Science.gov (United States)

    Roszelle, Breigh N; Deutsch, Steven; Manning, Keefe B

    2010-02-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV) as a flow visualization technique, however the small size and high curvature of the PVAD make other tools such as stereoscopic PIV impractical. In order to test the reliability of the 2D results, we perform a pseudo-3D PIV study using planes both parallel and normal to the diaphragm employing a mock circulatory loop containing a viscoelastic fluid that mimics 40% hematocrit blood. We find that while the third component of velocity is extremely helpful to a physical understanding of the flow, particularly of the diastolic jet and the development of a desired rotational pattern, the flow data taken parallel to the diaphragm is sufficient to describe the wall shear rates, a critical aspect to the study of thrombosis and design of such pumps.

  10. A multi-platform flow device for microbial (co- cultivation and microscopic analysis.

    Directory of Open Access Journals (Sweden)

    Matthijn C Hesselman

    Full Text Available Novel microbial cultivation platforms are of increasing interest to researchers in academia and industry. The development of materials with specialized chemical and geometric properties has opened up new possibilities in the study of previously unculturable microorganisms and has facilitated the design of elegant, high-throughput experimental set-ups. Within the context of the international Genetically Engineered Machine (iGEM competition, we set out to design, manufacture, and implement a flow device that can accommodate multiple growth platforms, that is, a silicon nitride based microsieve and a porous aluminium oxide based microdish. It provides control over (co-culturing conditions similar to a chemostat, while allowing organisms to be observed microscopically. The device was designed to be affordable, reusable, and above all, versatile. To test its functionality and general utility, we performed multiple experiments with Escherichia coli cells harboring synthetic gene circuits and were able to quantitatively study emerging expression dynamics in real-time via fluorescence microscopy. Furthermore, we demonstrated that the device provides a unique environment for the cultivation of nematodes, suggesting that the device could also prove useful in microscopy studies of multicellular microorganisms.

  11. CFD simulation of an internal spin-filter: evidence of lateral migration and exchange flow through the mesh.

    Science.gov (United States)

    Figueredo-Cardero, Alvio; Chico, Ernesto; Castilho, Leda R; Medronho, Ricardo A

    2009-11-01

    In the present work Computational Fluid Dynamics (CFD) was used to study the flow field and particle dynamics in an internal spin-filter (SF) bioreactor system. Evidence of a radial exchange flow through the filter mesh was detected, with a magnitude up to 130-fold higher than the perfusion flow, thus significantly contributing to radial drag. The exchange flow magnitude was significantly influenced by the filter rotation rate, but not by the perfusion flow, within the ranges evaluated. Previous reports had only given indirect evidences of this exchange flow phenomenon in spin-filters, but the current simulations were able to quantify and explain it. Flow pattern inside the spin-filter bioreactor resembled a typical Taylor-Couette flow, with vortices being formed in the annular gap and eventually penetrating the internal volume of the filter, thus being the probable reason for the significant exchange flow observed. The simulations also showed that cells become depleted in the vicinity of the mesh due to lateral particle migration. Cell concentration near the filter was approximately 50% of the bulk concentration, explaining why cell separation achieved in SFs is not solely due to size exclusion. The results presented indicate the power of CFD techniques to study and better understand spin-filter systems, aiming at the establishment of effective design, operation and scale-up criteria.

  12. A Point-of-Need infrared mediated PCR platform with compatible lateral flow strip for HPV detection.

    Science.gov (United States)

    Liu, Wenjia; Zhang, Mingfang; Liu, Xiaoyan; Sharma, Alok; Ding, Xianting

    2017-10-15

    With the increasing need of monitoring the epidemiology of serious infectious diseases, food hygiene, food additives and pesticide residues, it is urgent to develop portable, easy-to-use, inexpensive and rapid molecular diagnostic tools. Herein, we demonstrate a prototype of IR mediated Conducting Oil and CarbOn Nanotube circUlaTing PCR (IR-COCONUT PCR) platform for nucleic acid amplification. The presented platform offers a new solution for miniaturized PCR instruments with non-contact heaters by using conducting oil and carbon nanotube as a medium in IR mediated PCR. This novel platform offers accurate and flexible control of temperature through the integration of PID (proportional-integral-derivative) algorithms to manipulate the duty cycle of the voltage signals of IR LED and a peristaltic pump. The ramping rate of the introduced platform in current study is 1.5°C/s for heating speed and -2.0°C/s for cooling speed. This platform fulfills 30 thermal cycles within 50min which is a match to the conventional bench-top PCR thermo cyclers. For demonstration purpose, human papillomavirus (HPV) patient cervical swab specimens were examined. Downstream lateral flow strip (LFS) was also developed to quantity the PCR products from the IR-COCONUT PCR device within 25min. This PCR platform together with the compatible LFS shows great potential for in-field and Point-of-Need (PoN) testing of genetic or contagious diseases. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Laser-induced local activation of Mg-doped GaN with a high lateral resolution for high power vertical devices

    Science.gov (United States)

    Kurose, Noriko; Matsumoto, Kota; Yamada, Fumihiko; Roffi, Teuku Muhammad; Kamiya, Itaru; Iwata, Naotaka; Aoyagi, Yoshinobu

    2018-01-01

    A method for laser-induced local p-type activation of an as-grown Mg-doped GaN sample with a high lateral resolution is developed for realizing high power vertical devices for the first time. As-grown Mg-doped GaN is converted to p-type GaN in a confined local area. The transition from an insulating to a p-type area is realized to take place within about 1-2 μm fine resolution. The results show that the technique can be applied in fabricating the devices such as vertical field effect transistors, vertical bipolar transistors and vertical Schottkey diode so on with a current confinement region using a p-type carrier-blocking layer formed by this technique.

  14. Highly graphitized laterally interconnected SWCNT network synthesis via a sandwich-grown method

    International Nuclear Information System (INIS)

    Teng, I-Ju; Chen, Kai-Ling; Wang, Li-Chun; Kuo, Cheng-Tzu; Hsu, Hui-Lin; Jian, Sheng-Rui; Chen, Jung-Hsuan; Wang, Wei-Hsiang

    2011-01-01

    We present a sandwich-grown method for growing laterally interconnected single-walled carbon nanotube (SWCNT) networks with a high degree of graphitization by microwave plasma chemical vapour deposition (MPCVD). An Al 2 O 3 -supported Fe catalyst precursor layer deposited on an oxidized Si substrate with an upper Si cover is first pretreated in pure hydrogen, and then exposed to a gas mixture of methane/hydrogen for growth process at a lower growth temperature and a faster rate. The effects of various parameters, such as catalyst film thickness, gas flow rate, working pressure, growth time and plasma power, on the morphologies and structural characteristics of the SWCNT networks are investigated, and therefore provide the essential conditions for direct growth of laterally interconnected SWCNT networks. Analytical results demonstrate that the SWCNT-based lateral architecture comprises a mixture of graphene-sheet-wrapped catalyst particles and laterally interconnected nanotubes, isolated or branched or assembled into bundles. The results also show that the formation of the laterally interconnected SWCNT networks is related to the sandwich-like stack approach and the addition of an Al 2 O 3 layer in the MPCVD process. The successful growth of lateral SWCNT networks provides new experimental information for simply and efficiently preparing lateral SWCNTs on unpatterned substrates, and opens a pathway to create network-structured nanotube-based devices.

  15. Fluid-flow pressure measurements and thermo-fluid characterization of a single loop two-phase passive heat transfer device

    Science.gov (United States)

    Ilinca, A.; Mangini, D.; Mameli, M.; Fioriti, D.; Filippeschi, S.; Araneo, L.; Roth, N.; Marengo, M.

    2017-11-01

    A Novel Single Loop Pulsating Heat Pipe (SLPHP), with an inner diameter of 2 mm, filled up with two working fluids (Ethanol and FC-72, Filling Ratio of 60%), is tested in Bottom Heated mode varying the heating power and the orientation. The static confinement diameter for Ethanol and FC-72, respectively 3.4 mm and 1.7mm, is above and slightly under the inner diameter of the tube. This is important for a better understanding of the working principle of the device very close to the limit between the Loop Thermosyphon and Pulsating Heat Pipe working modes. With respect to previous SLPHP experiments found in the literature, such device is designed with two transparent inserts mounted between the evaporator and the condenser allowing direct fluid flow visualization. Two highly accurate pressure transducers permit local pressure measurements just at the edges of one of the transparent inserts. Additionally, three heating elements are controlled independently, so as to vary the heating distribution at the evaporator. It is found that peculiar heating distributions promote the slug/plug flow motion in a preferential direction, increasing the device overall performance. Pressure measurements point out that the pressure drop between the evaporator and the condenser are related to the flow pattern. Furthermore, at high heat inputs, the flow regimes recorded for the two fluids are very similar, stressing that, when the dynamic effects start to play a major role in the system, the device classification between Loop Thermosyphon and Pulsating Heat Pipe is not that sharp anymore.

  16. Gas-liquid flow splitting in T-junction with inclined lateral arm

    Science.gov (United States)

    Yang, Le-le; Liu, Shuo; Li, Hua; Zhang, Jian; Wu, Ying-xiang; Xu, Jing-yu

    2018-02-01

    This paper studies the gas-liquid flow splitting in T-junction with inclined lateral arm. The separation mechanism of the T-junction is related to the pressure distribution in the T-junction. It is shown that the separation efficiency strongly depends on the inclination angle, when the angle ranges from 0° to 30°, while not so strongly for angles in the range from 30° to 90° Increasing the number of connecting tubes is helpful for the gas-liquid separation, and under the present test conditions, with four connecting tubes, a good separation performance can be achieved. Accordingly, a multi-tube Y-junction separator with four connecting tubes is designed for the experimental investigation. A good agreement between the simulated and measured data shows that there is an optimal split ratio to achieve the best performance for the multi-tube Y-junction separator.

  17. Lateral nanowire/nanobelt based nanogenerators, piezotronics and piezo-phototronics

    KAUST Repository

    Wang, Zhong Lin

    2010-11-01

    Relying on the piezopotential created in ZnO under straining, nanogenerators, piezotronics and piezo-phototronics developed based on laterally bonded nanowires on a polymer substrate have been reviewed. The principle of the nanogenerator is a transient flow of electrons in external load as driven by the piezopotential created by dynamic straining. By integrating the contribution made by millions of nanowires, the output voltage has been raised to 1.2 V. Consequently, self-powered nanodevices have been demonstrated. This is an important platform technology for the future sensor network and the internet of things. Alternatively, the piezopotential can act as a gate voltage that can tune/gate the transport process of the charge carriers in the nanowire, which is a gate-electrode free field effect transistor (FET). The device fabricated based on this principle is called the piezotronic device. Piezo-phototronic effect is about the tuning and controlling of electro-optical processes by strain induced piezopotential. The piezotronic, piezophotonic and pieozo-phototronic devices are focused on low frequency applications in areas involving mechanical actions, such as MEMS/NEMS, nanorobotics, sensors, actuators and triggers. © 2010 Elsevier B.V. All rights reserved.

  18. Current development of microfluidic immunosensing approaches for mycotoxin detection via capillary electromigration and lateral flow technology.

    Science.gov (United States)

    Li, Peiwu; Zhang, Zhaowei; Zhang, Qi; Zhang, Ning; Zhang, Wen; Ding, Xiaoxia; Li, Ran

    2012-08-01

    Mycotoxin contamination in the food chain has caused serious health issues in humans and animals. Thus, a rapid on-site and lab-independent detection method for mycotoxins, such as aflatoxins (AFTs), is desirable. Microfluidic chip based immunosensor technology is one of the most promising methods for fast mycotoxin assays. In this review, we cover the major microfluidic immunosensors used for mycotoxin analysis, via flow-through (capillary electromigration) and lateral flow technology. Sample preparation from different matrices of agricultural products and foodstuffs is summarized. The choice of materials, fabrication strategies, and detection methods for microfluidic immunosensors are further discussed in detail. The sensors application in mycotoxin determination is also outlined. Finally, future challenges and opportunities are discussed. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A hybrid EKF and switching PSO algorithm for joint state and parameter estimation of lateral flow immunoassay models.

    Science.gov (United States)

    Zeng, Nianyin; Wang, Zidong; Li, Yurong; Du, Min; Liu, Xiaohui

    2012-01-01

    In this paper, a hybrid extended Kalman filter (EKF) and switching particle swarm optimization (SPSO) algorithm is proposed for jointly estimating both the parameters and states of the lateral flow immunoassay model through available short time-series measurement. Our proposed method generalizes the well-known EKF algorithm by imposing physical constraints on the system states. Note that the state constraints are encountered very often in practice that give rise to considerable difficulties in system analysis and design. The main purpose of this paper is to handle the dynamic modeling problem with state constraints by combining the extended Kalman filtering and constrained optimization algorithms via the maximization probability method. More specifically, a recently developed SPSO algorithm is used to cope with the constrained optimization problem by converting it into an unconstrained optimization one through adding a penalty term to the objective function. The proposed algorithm is then employed to simultaneously identify the parameters and states of a lateral flow immunoassay model. It is shown that the proposed algorithm gives much improved performance over the traditional EKF method.

  20. Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    In this work, a Computational Fluid-Dynamics (CFD) approach to model this phenomenon inside throttling devices is proposed. To validate CFD results, different nozzle geometries are analyzed, comparing numerical results with experimental data. Two cases are studied: Case 1: saturation steam/water mixture flow inside 2D convergent-divergent nozzle (inlet, outlet and throat diameter of nozzle are 0.1213m, 0.0452m and 0.0191m respectively). In this benchmark, a range of total inle...

  1. Aerodynamic analysis of potential use of flow control devices on helicopter rotor blades

    International Nuclear Information System (INIS)

    Tejero, F; Doerffer, P; Szulc, O

    2014-01-01

    The interest in the application of flow control devices has been rising in the last years. Recently, several passive streamwise vortex generators have been analysed in a configuration of a curved wall nozzle within the framework of the UFAST project (Unsteady Effects of Shock Wave Induced Separation, 2005 – 2009). Experimental and numerical results proved that the technology is effective in delaying flow separation. The numerical investigation has been extended to helicopter rotor blades in hover and forward flight applying the FLOWer solver (RANS approach) implementing the chimera overlapping grids technique and high performance computing. CFD results for hover conditions confirm that the proposed passive control method reduces the flow separation increasing the thrust over power consumption. The paper presents the numerical validation for both states of flight and the possible implementation of RVGs on helicopter rotor blades.

  2. Immunochromatographic Lateral-flow test strip for the rapid detection of added bovine rennet whey in milk and milk powder

    NARCIS (Netherlands)

    Martin-Hernandez, C.; Munoz, M.; Daury, C.; Weymuth, H.; Kemmers-Voncken, A.; Corbation, V.; Toribo, T.; Bremer, M.G.E.G.

    2009-01-01

    An immunochromatographic lateral-flow test dipstick test was developed for the fast detection of bovine rennet whey in liquid milk and milk powder. The test is based on the binding of casein glycomacropeptide (cGMP) by two specific anti-bovine ¿-casein monoclonal antibodies and has a visual

  3. 3-D flow analyses for design of nuclear fuel spacer

    Energy Technology Data Exchange (ETDEWEB)

    Karouta, Z. [ABB Combustion Engineering, Windsor, CT (United States); GU, Chun-Yuan [ABB Corporate Research, Vaesteras (Sweden); Schoelin, B. [ABB Atom AB, Vaesteras (Sweden)

    1995-09-01

    The Computational Fluid Dynamics (CFD) code, CFDS-FLOW3D, was used to develop improved fuel designs for PWR cores. It was used primarily to understand the fluid dynamics of grid spacers, the mass transfer between subchannels caused by spacers and in the long term to develop two-phase models which enable prediction of critical heat flux in PWR fuel. A single subchannel of one grid span was modeled. In this model different spacer designs with mixing devices were analyzed. A special treatment of the boundary condition was developed making use of flow symmetry to model the mass transfer between different subchannels and minimize the size of the computational model. This reduced the computational model to a fraction of a subchannel using traditional periodic boundary conditions. The Navier-Stokes equation was solved for the liquid and the flow turbulence was modeled by k-{xi} turbulence model. The spacer and mixing device were treated as infinite thin surfaces in the model and a zero velocity condition and turbulent wall function were applied on each side of the thin surfaces. This approach simulated the swirl from the mixing devices well, but had the drawback of not predicting pressure drop accurately since the wake behind the plates and the acceleration effect of the spacers were ignored. CFDS-FLOW3D models with mixing devices were applied in the single-phase flow regime. Velocity profiles from the CFDS-FLOW3D models were compared to Laser Doppler Velocimeter measurements taken from the flow field downstream of spaces in a full scale, cold water test loop. The predicted axial and lateral velocity profiles were in good agreement with the measurements. The evaluation of the performance of different spacer devices was made by comparing the swirl ratio downstream of the grid spacers. It is planned to evaluate heat transfer coefficient downstream of the spaces, to implement two-phase flow models, and to model the superheated boundary layer on the surface of the fuel rod.

  4. Laterally injected light-emitting diode and laser diode

    Science.gov (United States)

    Miller, Mary A.; Crawford, Mary H.; Allerman, Andrew A.

    2015-06-16

    A p-type superlattice is used to laterally inject holes into an III-nitride multiple quantum well active layer, enabling efficient light extraction from the active area. Laterally-injected light-emitting diodes and laser diodes can enable brighter, more efficient devices that impact a wide range of wavelengths and applications. For UV wavelengths, applications include fluorescence-based biological sensing, epoxy curing, and water purification. For visible devices, applications include solid state lighting and projection systems.

  5. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  6. Fabrication of an inexpensive photosensitive flow through device for turbidity measurement

    International Nuclear Information System (INIS)

    Morco, Ryan P.; Dawal, Micah S.; Sucgang, Raymond J.

    2014-01-01

    The aim of this study is the construction of a portable, simple to use, on-line photosensitive device which measures turbidity in water. The turbidity measuring device uses a light emitting diode, LED, light source shining on a light dependent resistor, LDR, which is connected in series to a circuit supplying a constant voltage and a digital voltmeter, DVM. Light shine through a tube containing the sample, and onto a photosensitive circuit. A clear tube of water is the BLANK and has zero absorbance. A fraction of the incident light that i obstructed by the turbidity of the sample can be used for calculable determination of turbidity in water. The turbidity is related to the absorbance reading, following Beer's law. The amount of incident and transmitted light are expressed in voltage units, by a voltmeter. The sample is delivered into the sampling chamber by a rubber tubing attached to a power head submersible pump which is immersed in the pool of water to be sampled. The instrument shows excellent response over the range o turbidity values (5NTU to 180 NTU). Linearity (R 2= 0.95) has been achieved using the device, working with 6 trials per particular NTU value. The NTU readings of the urbidity meter were calibrated against solutions of varying NTU's measured using a HORIBA multi-parameter probe. The other features of the device include: simplicity of operation, low-cost, rugged, handy and can be used in on-line and flow mode applications. (author)

  7. A new highly adaptable design of shear-flow device for orientation of macromolecules for Linear Dichroism (LD) measurement

    KAUST Repository

    Lundahl, P. Johan; Kitts, Catherine C.; Nordé n, Bengt

    2011-01-01

    This article presents a new design of flow-orientation device for the study of bio-macromolecules, including DNA and protein complexes, as well as aggregates such as amyloid fibrils and liposome membranes, using Linear Dichroism (LD) spectroscopy. The design provides a number of technical advantages that should make the device inexpensive to manufacture, easier to use and more reliable than existing techniques. The degree of orientation achieved is of the same order of magnitude as that of the commonly used concentric cylinders Couette flow cell, however, since the device exploits a set of flat strain-free quartz plates, a number of problems associated with refraction and birefringence of light are eliminated, increasing the sensitivity and accuracy of measurement. The device provides similar shear rates to those of the Couette cell but is superior in that the shear rate is constant across the gap. Other major advantages of the design is the possibility to change parts and vary sample volume and path length easily and at a low cost. © 2011 The Royal Society of Chemistry.

  8. The use of novel flow diverting device Tubridge for the treatment of intracranial aneurysms: initial experience

    International Nuclear Information System (INIS)

    Yang Pengfei; Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo; Zhao Wenyuan; Li Qiang; Fang Yibin; Zhang Yuhui

    2011-01-01

    Objective: To preliminarily evaluate the feasibility, efficacy and safety of the novel flow diverting device, Tubridge, in treating intracranial aneurysms. Methods: The novel flow diverting device, Tubridge, was employed to treat intracranial aneurysms in 14 patients with a mean age of (52.4±10.2) years. A total of 14 intracranial aneurysms were detected in 14 patients, including 13 un-ruptured aneurysms and one ruptured aneurysms. The technical results and clinical data were analyzed. Results: A total of 18 flow diverters were implanted. The flow diverter was successfully conveyed and delivered in all patients, with a technical success rate of 100%. Six aneurysms were treated with the flow diverter together with the coils. Of the six aneurysms, complete obliteration of the aneurysm was obtained in 2 (Raymond grade Ⅰ), remnant of neck was seen in 1 (Raymond grade Ⅱ) and residual aneurysm sac was found in 3 (Raymond grade Ⅲ) cases. Eight aneurysms were treated with flow diverter implantation alone. After the procedure, marked decrease in contrast filling of the aneurysm sac was seen in 3 aneurysms, while the change in contrast filling pattern of the aneurysm sac as well as the obvious retention of contrast in the aneurysm sac could be detected in all cases. No procedure-related hemorrhagic or ischemic complications occurred. The mRS score at the time of discharge was 0 (n=13) or 1 (n=1). Conclusion: For the treatment of some special type intracranial aneurysms, the use of Tubridge flow diverter is clinically feasible, its effect is immediate and satisfactory with higher safety in short term. However, its long-term efficacy and safety need to be further evaluated. (authors)

  9. Determination of glycated albumin using boronic acid-derived agarose beads on paper-based devices.

    Science.gov (United States)

    Ko, Euna; Tran, Van-Khue; Geng, Yanfang; Kim, Min Ki; Jin, Ga Hyun; Son, Seong Eun; Hur, Won; Seong, Gi Hun

    2018-01-01

    Self-monitoring of glycated albumin (GA), a useful glycemic marker, is an established method for preventing diabetes complications. Here, the paper-based lateral flow assay devices were developed for the sensitive detection of GA and the total human serum albumin (tHSA) in self-monitoring diabetes patients. Boronic acid-derived agarose beads were packed into a hole on a lateral flow channel. These well-coordinated agarose beads were used to capture GA through specific cis-diol interactions and to enhance the colorimetric signals by concentrating the target molecules. The devices exhibited large dynamic ranges (from 10  μ g/ml to 10 mg/ml for GA and from 10 mg/ml to 50 mg/ml for tHSA) and low detection limits (7.1  μ g/ml for GA and 4.7 mg/ml for tHSA), which cover the range of GA concentration in healthy plasma, which is 0.21-1.65 mg/ml (0.6%-3%). In determining the unknown GA concentrations in two commercial human plasma samples, the relative percentage difference between the values found by a standard ELISA kit and those found by our developed devices was 2.62% and 8.80%, which are within an acceptable range. The measurements of GA and tHSA were completed within 20 min for the total sample-to-answer diagnosis, fulfilling the demand for rapid analysis. Furthermore, the recovery values ranged from 99.4% to 110% in device accuracy tests. These results indicate that the developed paper-based device with boronic acid-derived agarose beads is a promising platform for GA and tHSA detection as applied to self-monitoring systems.

  10. Development and Evaluation of a Rapid Antigen Detection and Serotyping Lateral Flow Antigen Detection System for Foot-and-Mouth Disease Virus.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available We developed a lateral flow strip using monoclonal antibodies (MAbs which allows for rapid antigen detection and serotyping of foot-and-mouth disease virus (FMDV. This FMDV serotyping strip was able to detect all 7 serotypes and distinguish serotypes O, A, C and Asia1. Its sensitivities ranged from 10(3 to 10(4 of a 50% tissue culture infectious dose of each FMDV stain; this is equal to those of the commercial product Svanodip (Boehringer Ingelheim Svanova, Uppsala, Sweden, which can detect all seven serotypes of FMDV, but does not distinguish them. Our evaluation of the FMDV serotyping strip using a total of 118 clinical samples (vesicular fluids, vesicular epithelial emulsions and oral and/or nasal swabs showed highly sensitive antigen detection and accuracy in serotyping in accordance with ELISA or RT-PCR. To the best of our knowledge, this is the first report on any FMDV serotyping strip that provides both rapid antigen detection and serotyping of FMDV at the same time on one strip without extra devices. This method will be useful in both FMD-free countries and FMD-infected countries, especially where laboratory diagnosis cannot be carried out.

  11. Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.

    Science.gov (United States)

    Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J

    2014-03-01

    Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand

  12. Dynamic bioprocessing and microfluidic transport control with smart magnetic nanoparticles in laminar-flow devices.

    Science.gov (United States)

    Lai, James J; Nelson, Kjell E; Nash, Michael A; Hoffman, Allan S; Yager, Paul; Stayton, Patrick S

    2009-07-21

    In the absence of applied forces, the transport of molecules and particulate reagents across laminar flowstreams in microfluidic devices is dominated by the diffusivities of the transported species. While the differential diffusional properties between smaller and larger diagnostic targets and reagents have been exploited for bioseparation and assay applications, there are limitations to methods that depend on these intrinsic size differences. Here a new strategy is described for exploiting the sharply reversible change in size and magnetophoretic mobility of "smart" magnetic nanoparticles (mNPs) to perform bioseparation and target isolation under continuous flow processing conditions. The isolated 5 nm mNPs do not exhibit significant magnetophoretic velocities, but do exhibit high magnetophoretic velocities when aggregated by the action of a pH-responsive polymer coating. A simple external magnet is used to magnetophorese the aggregated mNPs that have captured a diagnostic target from a lower pH laminar flowstream (pH 7.3) to a second higher pH flowstream (pH 8.4) that induces rapid mNP disaggregation. In this second dis-aggregated state and flowstream, the mNPs continue to flow past the magnet rather than being immobilized at the channel surface near the magnet. This stimuli-responsive reagent system has been shown to transfer 81% of a model protein target from an input flowstream to a second flowstream in a continuous flow H-filter device.

  13. Experimental quantification of the fluid dynamics in blood-processing devices through 4D-flow imaging: A pilot study on a real oxygenator/heat-exchanger module.

    Science.gov (United States)

    Piatti, Filippo; Palumbo, Maria Chiara; Consolo, Filippo; Pluchinotta, Francesca; Greiser, Andreas; Sturla, Francesco; Votta, Emiliano; Siryk, Sergii V; Vismara, Riccardo; Fiore, Gianfranco Beniamino; Lombardi, Massimo; Redaelli, Alberto

    2018-02-08

    The performance of blood-processing devices largely depends on the associated fluid dynamics, which hence represents a key aspect in their design and optimization. To this aim, two approaches are currently adopted: computational fluid-dynamics, which yields highly resolved three-dimensional data but relies on simplifying assumptions, and in vitro experiments, which typically involve the direct video-acquisition of the flow field and provide 2D data only. We propose a novel method that exploits space- and time-resolved magnetic resonance imaging (4D-flow) to quantify the complex 3D flow field in blood-processing devices and to overcome these limitations. We tested our method on a real device that integrates an oxygenator and a heat exchanger. A dedicated mock loop was implemented, and novel 4D-flow sequences with sub-millimetric spatial resolution and region-dependent velocity encodings were defined. Automated in house software was developed to quantify the complex 3D flow field within the different regions of the device: region-dependent flow rates, pressure drops, paths of the working fluid and wall shear stresses were computed. Our analysis highlighted the effects of fine geometrical features of the device on the local fluid-dynamics, which would be unlikely observed by current in vitro approaches. Also, the effects of non-idealities on the flow field distribution were captured, thanks to the absence of the simplifying assumptions that typically characterize numerical models. To the best of our knowledge, our approach is the first of its kind and could be extended to the analysis of a broad range of clinically relevant devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Characterization of fluid forces exerted on a cylinder array oscillating laterally in axial flow

    International Nuclear Information System (INIS)

    Divaret, Lise

    2014-01-01

    This thesis presents an experimental and a numerical study of the fluid forces exerted on a cylinder or a cylinder array oscillating laterally in an axial flow. The parameters of the system are the amplitude, the oscillation frequency, the confinement and the length to diameter ratio of the cylinder. The objective is to determine the fluid damping created by the axial flow, i.e. the dissipative force. The industrial application of this thesis is the determination of the fluid damping of the fuel assemblies in the core of a nuclear power plant during an earthquake. The study focuses on the configurations where the oscillation velocity is small compared to the axial flow velocity. In a first part, we study the case of a cylinder with no confinement oscillating in axial flow. Two methods are used: a dynamical and a quasi-static approach. In dynamics, the damping rate is measured during free oscillations of the cylinder. In the quasi-static approach, the damping coefficient is calculated from the normal force measured on a yawed cylinder. The range of the small ratios between the oscillation and the axial flow velocities corresponds to a range of low yaw angle where the cylinder is in near-axial flow in statics. The case of a yawed cylinder has been studied both experimentally with experiments in a wind tunnel and numerically with CFD calculations. The analyses of the fluid forces shows that for yaw angles smaller than 5 degrees, a linear lift with the yaw angle creates the damping. The origin of the lift force is discussed from pressure and velocity measurements. The results of the quasi-static approach are compared to the results of the dynamical experiments. In a second part, an experimental study is performed on a rigid cylinder array made up of 40 cylinders oscillating in an axial flow. The normal force and the displacement of the cylinder array are measured simultaneously. The added mass and damping coefficient are calculated and their variation with the

  15. Principles of transverse flow fractionation of microparticles in superhydrophobic channels.

    Science.gov (United States)

    Asmolov, Evgeny S; Dubov, Alexander L; Nizkaya, Tatiana V; Kuehne, Alexander J C; Vinogradova, Olga I

    2015-07-07

    We propose a concept of fractionation of micron-sized particles in a microfluidic device with a bottom wall decorated by superhydrophobic stripes. The stripes are oriented at an angle α to the direction of a driving force, G, which generally includes an applied pressure gradient and gravity. Separation relies on the initial sedimentation of particles under gravity in the main forward flow, and their subsequent lateral deflection near a superhydrophobic wall due to generation of a secondary flow transverse to G. We provide some theoretical arguments allowing us to quantify the transverse displacement of particles in the microfluidic channel, and confirm the validity of theoretical predictions in test experiments with monodisperse fractions of microparticles. Our results can guide the design of superhydrophobic microfluidic devices for efficient sorting of microparticles with a relatively small difference in size and density.

  16. Integration of lateral porous silicon membranes into planar microfluidics.

    Science.gov (United States)

    Leïchlé, Thierry; Bourrier, David

    2015-02-07

    In this work, we present a novel fabrication process that enables the monolithic integration of lateral porous silicon membranes into single-layer planar microchannels. This fabrication technique relies on the patterning of local electrodes to guide pore formation horizontally within the membrane and on the use of silicon-on-insulator substrates to spatially localize porous silicon within the channel depth. The feasibility of our approach is studied by current flow analysis using the finite element method and supported by creating 10 μm long mesoporous membranes within 20 μm deep microchannels. The fabricated membranes are demonstrated to be potentially useful for dead-end microfiltration by adequately retaining 300 nm diameter beads while macromolecules such as single-stranded DNA and immunoglobulin G permeate the membrane. The experimentally determined fluidic resistance is in accordance with the theoretical value expected from the estimated pore size and porosity. The work presented here is expected to greatly simplify the integration of membranes capable of size exclusion based separation into fluidic devices and opens doors to the use of porous silicon in planar lab on a chip devices.

  17. Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns

    Science.gov (United States)

    Bose, Suman; Singh, Rishi; Hanewich-Hollatz, Mikhail; Shen, Chong; Lee, Chia-Hua; Dorfman, David M.; Karp, Jeffrey M.; Karnik, Rohit

    2013-07-01

    Flow fractionation of cells using physical fields to achieve lateral displacement finds wide applications, but its extension to surface molecule-specific separation requires labeling. Here we demonstrate affinity flow fractionation (AFF) where weak, short-range interactions with asymmetric molecular patterns laterally displace cells in a continuous, label-free process. We show that AFF can directly draw neutrophils out of a continuously flowing stream of blood with an unprecedented 400,000-fold depletion of red blood cells, with the sorted cells being highly viable, unactivated, and functionally intact. The lack of background erythrocytes enabled the use of AFF for direct enumeration of neutrophils by a downstream detector, which could distinguish the activation state of neutrophils in blood. The compatibility of AFF with capillary microfluidics and its ability to directly separate cells with high purity and minimal sample preparation will facilitate the design of simple and portable devices for point-of-care diagnostics and quick, cost-effective laboratory analysis.

  18. Cellphone-based devices for bioanalytical sciences

    Science.gov (United States)

    Vashist, Sandeep Kumar; Mudanyali, Onur; Schneider, E.Marion; Zengerle, Roland; Ozcan, Aydogan

    2014-01-01

    During the last decade, there has been a rapidly growing trend toward the use of cellphone-based devices (CBDs) in bioanalytical sciences. For example, they have been used for digital microscopy, cytometry, read-out of immunoassays and lateral flow tests, electrochemical and surface plasmon resonance based bio-sensing, colorimetric detection and healthcare monitoring, among others. Cellphone can be considered as one of the most prospective devices for the development of next-generation point-of-care (POC) diagnostics platforms, enabling mobile healthcare delivery and personalized medicine. With more than 6.5 billion cellphone subscribers worldwide and approximately 1.6 billion new devices being sold each year, cellphone technology is also creating new business and research opportunities. Many cellphone-based devices, such as those targeted for diabetic management, weight management, monitoring of blood pressure and pulse rate, have already become commercially-available in recent years. In addition to such monitoring platforms, several other CBDs are also being introduced, targeting e.g., microscopic imaging and sensing applications for medical diagnostics using novel computational algorithms and components already embedded on cellphones. This manuscript aims to review these recent developments in CBDs for bioanalytical sciences along with some of the challenges involved and the future opportunities. PMID:24287630

  19. Anomalous output characteristic shift for the n-type lateral diffused metal-oxide-semiconductor transistor with floating P-top layer

    International Nuclear Information System (INIS)

    Liu, Siyang; Zhang, Chunwei; Sun, Weifeng; Su, Wei; Wang, Shaorong; Ma, Shulang; Huang, Yu

    2014-01-01

    Anomalous output characteristic shift of the n-type lateral diffused metal-oxide-semiconductor transistor with floating P-top layer is investigated. It shows that the linear drain current has obvious decrease when the output characteristic of fresh device is measured for two consecutive times. The charge pumping experiments demonstrate that the decrease is not from hot-carrier degradation. The reduction of cross section area for the current flowing, which results from the squeezing of the depletion region surrounding the P-top layer, is responsible for the shift. Consequently, the current capability of this special device should be evaluated by the second measured output characteristic

  20. Anomalous output characteristic shift for the n-type lateral diffused metal-oxide-semiconductor transistor with floating P-top layer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Siyang; Zhang, Chunwei; Sun, Weifeng, E-mail: swffrog@seu.edu.cn [National ASIC System Engineering Research Center, Southeast University, Nanjing 210096 (China); Su, Wei; Wang, Shaorong; Ma, Shulang; Huang, Yu [CSMC Technologies Corporation, Wuxi 214061 (China)

    2014-04-14

    Anomalous output characteristic shift of the n-type lateral diffused metal-oxide-semiconductor transistor with floating P-top layer is investigated. It shows that the linear drain current has obvious decrease when the output characteristic of fresh device is measured for two consecutive times. The charge pumping experiments demonstrate that the decrease is not from hot-carrier degradation. The reduction of cross section area for the current flowing, which results from the squeezing of the depletion region surrounding the P-top layer, is responsible for the shift. Consequently, the current capability of this special device should be evaluated by the second measured output characteristic.

  1. Numerically Simulated Impact of Gas Prandtl Number and Flow Model on Efficiency of the Machine-less Energetic Separation Device

    Directory of Open Access Journals (Sweden)

    K. S. Egorov

    2015-01-01

    Full Text Available The presented paper regards the influence of one of similarity criteria – the Prandtl number of gas (Pr - on the efficiency of the machine-less energetic separation device (Leontiev pipe, using numerical modeling in ANSYS software. This device, equally as Rank-Hilsch and Hartman-Schprenger pipes, is designed to separate one gas flow into two flows with different temperatures. One flow (supersonic streams out of the pipe with a temperature higher than initial and the other (subsonic flows out with a temperature lower than initial. This direction of energetic separation is true if the Prandtl number is less than 1 that corresponds to gases.The Prandtl number affects the efficiency of running Leontiev pipe indirectly both through a temperature difference on which a temperature recovery factor has an impact and through a thermal conductivity coefficient that shows the impact of heat transfer intensity between gas and solid wall.The Prandtl number range in the course of research was from 0.1 to 0.7. The Prandtl number value equal to 0.7 corresponds to the air or pure gases (for example, inert argon gas. The Prandtl number equal to 0.2 corresponds to the mixtures of inert gases such as helium-xenon.The numerical modeling completed for the supersonic flow with Mach number 2.0 shows that efficiency of the machine-less energetic separation device has been increased approximately 2 times with the Prandtl number decreasing from 0.7 to 0.2. Moreover, for the counter-flow scheme this effect is a little higher due to its larger heat efficiency in comparison with the straight-flow one.Also, the research shows that the main problem for the further increase of the Leontiev pipe efficiency is a small value of thermal conductivity coefficient, which requires an intensification of the heat exchange, especially in the supersonic flow. It can be obtained, for example, by using a system of oblique shock waves in the supersonic channel.

  2. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  3. Pilot study of a new device to titrate oxygen flow in hypoxic patients on long-term oxygen therapy.

    Science.gov (United States)

    Cirio, Serena; Nava, Stefano

    2011-04-01

    The O(2) Flow Regulator (Dima, Bologna, Italy) is a new automated oxygen regulator that titrates the oxygen flow based on a pulse-oximetry signal to maintain a target S(pO(2)). We tested the device's safety and efficacy. We enrolled 18 subjects with chronic lung disease, exercise-induced desaturation, and on long-term oxygen therapy, in a randomized crossover study with 2 constant-work-load 15-min cycling exercise tests, starting with the patient's previously prescribed usual oxygen flow. In one test the oxygen flow was titrated manually by the respiratory therapist, and in the other test the oxygen flow was titrated by the O(2) Flow Regulator, to maintain an S(pO(2)) of 94%. We measured S(pO(2)) throughout each test, the time spent by the respiratory therapist to set the device or to manually regulate the oxygen flow, and the total number of respiratory-therapist titration interventions during the trial. There were no differences in symptoms or heart rate between the exercise tests. Compared to the respiratory-therapist-controlled tests, during the O(2) Flow Regulator tests S(pO(2)) was significantly higher (95 ± 2% vs 93 ± 3%, P = .04), significantly less time was spent below the target S(pO(2)) (171 ± 187 s vs 340 ± 220 s, P less respiratory therapist time (5.6 ± 3.7 min vs 2.0 ± 0.1 min, P = .005). The O(2) Flow Regulator may be a safe and effective alternative to manual oxygen titration during exercise in hypoxic patients. It provided stable S(pO(2)) and avoided desaturations in our subjects.

  4. Sieve-based lateral displacement technology for suspension separation

    NARCIS (Netherlands)

    Dijkshoorn, J.P.; Wagterveld, R.M.; Boom, R.M.; Schutyser, M.A.I.

    2017-01-01

    Sparse lateral displacement arrays are easier to scale up than full deterministic lateral displacement arrays or deterministic ratchets, because they require lower pressure drop and simplify the construction of the device. However, the asymmetry of sparse arrays leads to a non-homogeneous pressure

  5. Mixing in a Microfluid Device

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Deryabin, Mikhail

    Mixing of fluids in microchannels cannot rely on turbulence since the flow takes place at extremly low Reynolds numbers. Various active and passive devices have been developed to induce mixing in microfluid flow devices. We describe here a model of an active mixer where a transverse periodic flow...

  6. A continuous flow micro filtration device for plasma/blood separation using submicron vertical pillar gap structures

    International Nuclear Information System (INIS)

    Kang, Tae Goo; Ji, Hongmiao; Lim, Pei Yi; Chen, Yu; Yoon, Yong-Jin

    2014-01-01

    This work demonstrates a continuous flow plasma/blood separator using a vertical submicron pillar gap structure. The working principle of the proposed separator is based on size exclusion of cells through cross-flow filtration, in which only plasma is allowed to pass through submicron vertical pillars located tangential to the main flow path of the blood sample. The maximum filtration efficiency of 99.9% was recorded with a plasma collection rate of 0.67 µl min −1 for an input blood flow rate of 12.5 µl min −1 . The hemolysis phenomenon was observed for an input blood flow rate above 30 µl min −1 . Based on the experimental results, we can conclude that the proposed device shows potential for the application of on-chip plasma/blood separation as a part of integrated point-of-care (POC) diagnostics systems. (technical note)

  7. An alternative treatment of heat flow for charge transport in semiconductor devices

    International Nuclear Information System (INIS)

    Grupen, Matt

    2009-01-01

    A unique thermodynamic model of Fermi gases suitable for semiconductor device simulation is presented. Like other models, such as drift diffusion and hydrodynamics, it employs moments of the Boltzmann transport equation derived using the Fermi-Dirac distribution function. However, unlike other approaches, it replaces the concept of an electron thermal conductivity with the heat capacity of an ideal Fermi gas to determine heat flow. The model is used to simulate a field-effect transistor and show that the external current-voltage characteristics are strong functions of the state space available to the heated Fermi distribution.

  8. Data flow between RFID devices in a modern restricted access administrative office

    Directory of Open Access Journals (Sweden)

    Robert Waszkowski

    2016-01-01

    Full Text Available The paper presents models of data flow between RFID devices in a modern restricted access administrative office. The presented diagrams are the result of the analytical work performed by the multidisciplinary team of experts. The team was composed of IT specialist, security systems specialists and employees of the secret office. The presented models include the fact that the facilities in the secret office (cabinet, sluice, photocopier, desks are equipped with the RFID reader, which allows to immediately read the documents that are within their reach.

  9. Suppression of Lateral Diffusion and Surface Leakage Currents in nBn Photodetectors Using an Inverted Design

    Science.gov (United States)

    Du, X.; Savich, G. R.; Marozas, B. T.; Wicks, G. W.

    2018-02-01

    Surface leakage and lateral diffusion currents in InAs-based nBn photodetectors have been investigated. Devices fabricated using a shallow etch processing scheme that etches through the top contact and stops at the barrier exhibited large lateral diffusion current but undetectably low surface leakage. Such large lateral diffusion current significantly increased the dark current, especially in small devices, and causes pixel-to-pixel crosstalk in detector arrays. To eliminate the lateral diffusion current, two different approaches were examined. The conventional solution utilized a deep etch process, which etches through the top contact, barrier, and absorber. This deep etch processing scheme eliminated lateral diffusion, but introduced high surface current along the device mesa sidewalls, increasing the dark current. High device failure rate was also observed in deep-etched nBn structures. An alternative approach to limit lateral diffusion used an inverted nBn structure that has its absorber grown above the barrier. Like the shallow etch process on conventional nBn structures, the inverted nBn devices were fabricated with a processing scheme that only etches the top layer (the absorber, in this case) but avoids etching through the barrier. The results show that inverted nBn devices have the advantage of eliminating the lateral diffusion current without introducing elevated surface current.

  10. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  11. Dielectrokinetic chromatography devices

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-12-16

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  12. System for measurement and automatic regulation of gas flow within an oil aging test device

    Directory of Open Access Journals (Sweden)

    Žigić Aleksandar

    2014-01-01

    Full Text Available This paper describes a system within an oil aging test device that serves for measurement and automatic regulation of gas flow. Following an already realized system that continuously monitors, logs, and regulates transformer oil temperature during the aging process and maintains temperature consistency within strict limits, a model of a flow meter and regulator of air or oxygen through transformer oil samples is developed. A special feature of the implemented system is the measurement of very small gas flows. A short technical description of the realized system is given with a functional block diagram. The basic technical characteristics of the system are specified, and the operating principles and application of the system are described. The paper also gives performance test results in a real exploitation environment.

  13. Broken flow symmetry explains the dynamics of small particles in deterministic lateral displacement arrays.

    Science.gov (United States)

    Kim, Sung-Cheol; Wunsch, Benjamin H; Hu, Huan; Smith, Joshua T; Austin, Robert H; Stolovitzky, Gustavo

    2017-06-27

    Deterministic lateral displacement (DLD) is a technique for size fractionation of particles in continuous flow that has shown great potential for biological applications. Several theoretical models have been proposed, but experimental evidence has demonstrated that a rich class of intermediate migration behavior exists, which is not predicted. We present a unified theoretical framework to infer the path of particles in the whole array on the basis of trajectories in a unit cell. This framework explains many of the unexpected particle trajectories reported and can be used to design arrays for even nanoscale particle fractionation. We performed experiments that verify these predictions and used our model to develop a condenser array that achieves full particle separation with a single fluidic input.

  14. A Novel Electronic Device for Measuring Urine Flow Rate: A Clinical Investigation

    Directory of Open Access Journals (Sweden)

    Aliza Goldman

    2017-09-01

    Full Text Available Objective: Currently, most vital signs in the intensive care unit (ICU are electronically monitored. However, clinical practice for urine output (UO measurement, an important vital sign, usually requires manual recording of data that is subject to human errors. In this study, we assessed the ability of a novel electronic UO monitoring device to measure real-time hourly UO versus current clinical practice. Design: Patients were connected to the RenalSense Clarity RMS Sensor Kit with a sensor integrated within a standard sterile urinary catheter drainage tube to monitor urine flow in real time. The Clarity RMS Sensor Kit was modified to incorporate a standard urinometer (Unomedical for the nursing staff to record UO as per their standard practice. The drainage bag was placed in a container on a scientific scale (Precisa BJ to be used as the gold standard. Interventions: Nursing records for hourly UO were collected and compared with the electronically recorded UO. Sensor measurements and nursing staff manual records of UO were compared with the scale data. Setting: The study setting was the ICU of Hadassah Hospital, Jerusalem. Patients: Data from 23 patients with a urinary catheter were observed in this study. Measurements and main results: A total of 1046 hours of UO were recorded from 23 subjects. Compared with the scale data, the measurements of hourly urine flow measured with the RenalSense system were closer, had a better correlation, and narrower limits of agreement to gravimetrically determined values than the measurements obtained by the nurses. In addition, continuous monitoring of UO provided graphical display of response to repeated diuretic administration. Conclusions: An electronic device for recording UO has been shown to provide more reliable information of UO records and patient fluid status than current practice. Future applications of this device will provide valuable information to help set protocol goals such as decisions for

  15. Point-of-care Devices: Non-Newtonian Whole Blood Behavior and Capillary Flow on Reagent-coated Walls

    Directory of Open Access Journals (Sweden)

    Jean BERTHIER

    2016-08-01

    Full Text Available Most point-of-care (POC and patient self-testing (PST devices are based on the analysis of whole blood taken from a finger prick. Whole blood contains a bountiful of information about the donor’s health. We analyze here two particularities of microsystems for blood analysis: the blood non-Newtonian behavior, and the capillary flow in reagent-coated channels. Capillarity is the most commonly used method to move fluids in portable systems. It is shown first that the capillary flow of blood does not follow the Lucas-Washburn-Rideal law when the capillary flow velocity is small, due to its non-Newtonian rheology and to the formation of rouleaux of RBCs. In a second step, the capillary flow of blood on reagent-coated surfaces is investigated; first experimentally by observing the spreading of a droplet of blood on different reagent-coated substrates; second theoretically and numerically using the general law for spontaneous capillary flows and the Evolver numerical program.

  16. Contribution of lateral terrestrial water flows to the regional hydrological cycle: A joint soil-atmospheric moisture tagging procedure with WRF-Hydro

    Science.gov (United States)

    Arnault, Joel; Wei, Jianhui; Zhang, Zhenyu; Wagner, Sven; Kunstmann, Harald

    2017-04-01

    Water resources management requires an accurate knowledge of the behavior of the regional hydrological cycle components, including precipitation, evapotranspiration, river discharge and soil water storage. Atmospheric models such as the Weather Research and Forecasting (WRF) model provide a tool to evaluate these components. The main drawback of these atmospheric models, however, is that the terrestrial segment of the hydrological cycle is reduced to vertical infiltration, and that lateral terrestrial water flows are neglected. Recent model developments have focused on coupled atmospheric-hydrological modeling systems, such as WRF-hydro, in order to take into account subsurface, overland and river flow. The aim of this study is to investigate the contribution of lateral terrestrial water flows to the regional hydrological cycle, with the help of a joint soil-atmospheric moisture tagging procedure. This procedure is the extended version of an existing atmospheric moisture tagging method developed in WRF and WRF-Hydro (Arnault et al. 2017). It is used to quantify the partitioning of precipitation into water stored in the soil, runoff, evapotranspiration, and potentially subsequent precipitation through regional recycling. An application to a high precipitation event on 23 June 2009 in the upper Danube river basin, Germany and Austria, is presented. Precipitating water during this day is tagged for the period 2009-2011. Its contribution to runoff and evapotranspiration decreases with time, but is still not negligible in the summer 2011. At the end of the study period, less than 5 % of the precipitating water on 23 June 2009 remains in the soil. The additionally resolved lateral terrestrial water flows in WRF-Hydro modify the partitioning between surface and underground runoff, in association with a slight increase of evapotranspiration and recycled precipitation. Reference: Arnault, J., R. Knoche, J. Wei, and H. Kunstmann (2016), Evaporation tagging and atmospheric

  17. Universal chemiluminescence flow-through device based on directed self-assembly of solid-state organic chromophores on layered double hydroxide matrix.

    Science.gov (United States)

    Wang, Zhihua; Teng, Xu; Lu, Chao

    2013-02-19

    In this work, a universal chemiluminescence (CL) flow-through device suitable for various CL resonance energy transfer (CRET) systems has been successfully fabricated. Highly efficient CRET in solid-state photoactive organic molecules can be achieved by assembling them on the surface of layered double hydroxides (LDHs). We attribute these observations to the suppression of the intermolecular π-π stacking interactions among aromatic rings and the improvement of molecular orientation and planarity in the LDH matrix, enabling a remarkable increase in fluorescence lifetime and quantum yield of organic molecules. Under optimal conditions, using peroxynitrous acid-fluorescein dianion (FLUD) as a model CRET system, trace FLUD (10 μM) was assembled on the surface of LDHs. Peroxynitrous acid/nitrite could be assayed in the range of 1.0-500 μM, and the detection limit for peroxynitrous acid/nitrite (S/N = 3) was 0.6 μM. This CL flow-through device exhibited operational stability, high reproducibility, and long lifetime. While LDHs were immobilized in a flow-through device in the absence of FLUD, the detection limit for peroxynitrous acid/nitrite was 100 μM. On the other hand, FLUD at the same concentration can not enhance the CL intensity of peroxynitrous acid system. This fabricated CL flow-through column has been successfully applied to determine nitrite in sausage samples with recoveries of 98-102%. These satisfactory results demonstrated that our studies pave a novel way toward flow-through column-based CRET using solid-state organic molecules as acceptors for signal amplification.

  18. [In vitro study of the flow duration of antibiotics solutions prepared in elastomeric infusion devices: effect of cold storage for 3 to 7days].

    Science.gov (United States)

    Grangeon-Chapon, C; Robein-Dobremez, M-J; Pin, I; Trouiller, P; Allenet, B; Foroni, L

    2015-09-01

    Within the cystic fibrosis patients' home care, EMERAA network ("Together against Cystic fibrosis in Rhone-Alpes and Auvergne") organizes parenteral antibiotics cures at home prepared in elastomeric infusion devices by hospital pharmacies. However, patients and nurses found that the durations of infusion with these devices were often longer than the nominal duration of infusion indicated by their manufacturer. This study aimed to identify the potential different causes in relation to these discordances. Three hundred and ninety devices of two different manufacturers are tested in different experimental conditions: three antibiotics each at two different doses, duration of cold storage (three days or seven days) or immediate tests without cold storage, preparation and storage of the solution in the device (protocol Device) or transfer in the device just before measurement (protocol Pocket). All tests highlighted a longer flow duration for devices prepared according to the protocol Device versus the protocol Pocket (P=0.004). Flow duration is increased in the case of high doses of antibiotics with high viscosity such as piperacilline/tazobactam. The results of this in vitro study showed the impact of: (1) the time between the filling of the device and the flow of the solution; (2) cold storage of elastomeric infusion devices; (3) concentration of antibiotics and therefore the viscosity of the solution to infuse. It is therefore essential that health care teams are aware of factors, which may lead to longer infusion durations with these infusion devices. When the additional time for infusion remain acceptable, it should be necessary to inform the patient and to relativize these lengthening compared to many benefits that these devices provide for home care. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Continental slope sea level and flow variability induced by lateral movements of the Gulf Stream in the Middle Atlantic Bight

    Science.gov (United States)

    Böhm, E.; Hopkins, T. S.; Pietrafesa, L. J.; Churchill, J. H.

    2006-08-01

    As described by [Csanady, G.T., Hamilton, P., 1988. Circulation of slope water. Continental Shelf Research 8, 565-624], the flow regime over the slope of the southern Middle Atlantic Bight (MAB) includes a current reversal in which southwestward flow over the upper and middle slope becomes entrained in the northeastward current adjacent to the Gulf Stream. In this paper we use satellite-derived data to quantify how lateral motions of the Gulf Stream impact this current system. In our analysis, the Gulf Stream’s thermal front is delineated using a two-year time series of sea surface temperature derived from NOAA/AVHRR satellite data. Lateral motions of the Gulf Stream are represented in terms of temporal variations of the area, east of 73°W, between the Gulf Stream thermal front and the shelf edge. Variations of slope water flow within this area are represented by anomalies of geostrophic velocity as derived from the time series of the sea level anomaly determined from TOPEX/POSEIDON satellite altimeter data. A strong statistical relationship is found between Gulf Stream displacements and parabathic flow over the continental slope. It is such that the southwestward flow over the slope is accelerated when the Gulf Stream is relatively far from the shelf edge, and is decelerated (and perhaps even reversed) when the Gulf Stream is close to the shelf edge. This relationship between Gulf Stream displacements and parabathic flow is also observed in numerical simulations produced by the Miami Isopycnic Coordinate Model. In qualitative terms, it is consistent with the notion that when the Gulf Stream is closer to the 200-m isobath, it is capable of entraining a larger fraction of shelf water masses. Alternatively, when the Gulf Stream is far from the shelf-break, more water is advected into the MAB slope region from the northeast. Analysis of the diabathic flow indicates that much of the cross-slope transport by which the southwestward flow entering the study region is

  20. Modeling multi-lateral wells

    Energy Technology Data Exchange (ETDEWEB)

    Su, H. J.; Fong, W. S. [Chevron Petroleum Technology Company (United States)

    1998-12-31

    A method for modeling multi-lateral wells by using a computational scheme embedded in a general-purpose, finite difference simulator was described. The calculation of wellbore pressure profile for each lateral included the frictional pressure drop along the wellbore and proper fluid mixing at lateral connection points. To obtain a good production profile the Beggs and Brill correlation, a homogenous flow model, and the model proposed by Ouyang et al, which includes an acceleration term and accounts for the lubrication effect due to radial influx, were implemented. Well performance prediction results were compared using the three models. The impact of different tubing sizes on the well performance and the prediction contribution from each lateral were also studied. Results of the study in the hypothetical example and under normal field operating conditions were reviewed. 7 refs., 10 tabs., 3 figs.

  1. A Lateral Flow Rapid Test for Human Toxocariasis Developed Using Three Toxocara canis Recombinant Antigens.

    Science.gov (United States)

    Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah

    2018-01-01

    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.

  2. Study of ion flow dynamics in an inertial electrostatic confinement device through sequential grid construction

    International Nuclear Information System (INIS)

    Murali, S. Krupakar; Kulcinski, G. L.; Santarius, J. F.

    2008-01-01

    Experiments were performed to understand the dynamics of the ion flow in an inertial electrostatic confinement (IEC) device. This was done by monitoring the fusion rate as the symmetry of the grid was increased starting with a single loop all the way until the entire grid is constructed. The fusion rate was observed to increase with grid symmetry and eventually saturate. A single loop grid was observed to generate a cylindrical (∼line) fusion source. The ion flow distribution was measured by introducing fine wires across a single loop of the grid in the form of a chord of a circle (chord wires). This study revealed that with increased symmetry of the cathode grid wires the convergence of the ions improves. The chord wires provided electrons for ionization even at low pressures (∼6.67 mPa) and helped sustain the plasma. The impinging ions heat these wires locally and the temperature of the wires was measured using an infrared thermometer that was used to understand the ion flow distribution across the cathode grid. The presence of the grid wires seems to affect the fusion rate more drastically than previously thought (was assumed to be uniform around the central grid). Most of the fusion reactions were observed to occur in the ion microchannels that form in gaps between the cathode wires. This work helps understand the fusion source regimes and calibrate the IEC device.

  3. Studies on diversion cross-flow between two parallel channels communicating by a lateral slot. II

    International Nuclear Information System (INIS)

    Tapucu, A.; Merilo, M.

    1977-01-01

    The axial pressure variations of two parallel channels with single phase flows communicating by a long lateral slot have been studied experimentally. Using mass and momentum conservation principles, the axial pressure variations have been derived in terms of two parameters ksub(d) and ksub(r), for donor and recipient channels, respectively. These parameters include the combined effect of fluid transferred from donor to recipient channel, and drag force brought on by the connection gap, and are functions of the velocities and slot geometry parameters. A pressure difference oscillation between channels along the slot has been detected which is sinusoidal with wave lengths which seem to be a function of the gap clearance. (Auth.)

  4. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    Science.gov (United States)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  5. Chromatographic Separation and Visual Detection on Wicking Microfluidic Devices: Quantitation of Cu2+ in Surface, Ground, and Drinking Water.

    Science.gov (United States)

    Bandara, Gayan C; Heist, Christopher A; Remcho, Vincent T

    2018-02-20

    Copper is widely applied in industrial and technological applications and is an essential micronutrient for humans and animals. However, exposure to high environmental levels of copper, especially through drinking water, can lead to copper toxicity, resulting in severe acute and chronic health effects. Therefore, regular monitoring of aqueous copper ions has become necessary as recent anthropogenic activities have led to elevated environmental concentrations of copper. On-site monitoring processes require an inexpensive, simple, and portable analytical approach capable of generating reliable qualitative and quantitative data efficiently. Membrane-based lateral flow microfluidic devices are ideal candidates as they facilitate rapid, inexpensive, and portable measurements. Here we present a simple, chromatographic separation approach in combination with a visual detection method for Cu 2+ quantitation, performed in a lateral flow microfluidic channel. This method appreciably minimizes interferences by incorporating a nonspecific polymer inclusion membrane (PIM) based assay with a "dot-counting" approach to quantification. In this study, hydrophobic polycaprolactone (PCL)-filled glass microfiber (GMF) membranes were used as the base substrate onto which the PIM was evenly dispensed as an array of dots. The devices thus prepared were then selectively exposed to oxygen radicals through a mask to generate a hydrophilic surface path along which the sample was wicked. Using this approach, copper concentrations from 1 to 20 ppm were quantified from 5 μL samples using only visual observation of the assay device.

  6. Lateral power transistors in integrated circuits

    CERN Document Server

    Erlbacher, Tobias

    2014-01-01

    This book details and compares recent advancements in the development of novel lateral power transistors (LDMOS devices) for integrated circuits in power electronic applications. It includes the state-of-the-art concept of double-acting RESURF topologies.

  7. Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges

    International Nuclear Information System (INIS)

    Kolosova, Anna Yu.; Sibanda, Liberty; Dumoulin, Frederic; Lewis, Janet; Duveiller, Etienne; Van Peteghem, Carlos; Saeger, Sarah de

    2008-01-01

    A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 μg kg -1 were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities

  8. HistoFlex-a microfluidic device providing uniform flow conditions enabling highly sensitive, reproducible and quantitative in situ hybridizations

    DEFF Research Database (Denmark)

    Søe, Martin Jensen; Okkels, Fridolin; Sabourin, David

    2011-01-01

    A microfluidic device (the HistoFlex) designed to perform and monitor molecular biological assays under dynamic flow conditions on microscope slide-substrates, with special emphasis on analyzing histological tissue sections, is presented. Microscope slides were reversibly sealed onto a cast polyd...

  9. Use of integrity control and automatic start of reserve in a multi-channel temperature and flow rate control device

    International Nuclear Information System (INIS)

    Strzalkowski, L.

    1975-01-01

    A way to increase reliability of process quantity control is control of the integrity of the control plants themselves. The possibilities of integrity control on control devices having simply duplicated control channels or working on the basis of the ''two-from-three'' principle are valued. A highly reliable integrity control is possible by use of test signals. For an appropriate control device, structure and function of the assemblies are described. The integrity control device may be used in the water coolant temperature and flow rate control system for all technological channels of the research reactor ''Maria''

  10. Centrifugal Separation Device Based on Two-Layer Laminar Flow in Microchannels for High-Throughput and Continuous Blood Cell/Plasma Separation

    Science.gov (United States)

    Taizo Kobayashi,; Taisuke Funamoto,; Makoto Hosaka,; Satoshi Konishi,

    2010-07-01

    This paper presents a novel type of centrifugation device that is based on the two-layer laminar flow in micro flow channels for continuous blood cell/plasma separation. We propose to rotate the flow channels which are arranged along the circumference around the rotational axis. Downsizing the channel width reduced both the cell sedimentation time and the required centrifugal force, because the channel width corresponds to the centrifugal sedimentation length. First, plasma and cells were continuously extracted from pig blood in each of the branch channels using a milled acrylic prototype device (channel width = 800 μm, volume = 150 μl). Next, the relationship between the channel width (125, 250, and 500 μm) and the sedimentation time taken for various centrifugal forces (2.3, 9, 36, and 145 G) was evaluated using the downsized microchannels fabricated by hot-embossing and thermal bonding technologies. Using downsized microchannels with a width of 125 μm successfully reduced the sedimentation time to 85 s as compared to the sedimentation time of 270 s for a channel of a width of 500 μm, when a centrifugal force of 2.3 G was applied. The use of the proposed device did not result in obvious hemolysis at the centrifugal forces lower than 335 G.

  11. A high efficiency lateral light emitting device on SOI

    NARCIS (Netherlands)

    Hoang, T.; Le Minh, P.; Holleman, J.; Zieren, V.; Goossens, M.J.; Schmitz, Jurriaan

    2005-01-01

    The infrared light emission of lateral p/sup +/-p-n/sup +/ diodes realized on SIMOX-SOI (separation by implantation of oxygen - silicon on insulator) substrates has been studied. The confinement of the free carriers in one dimension due to the buried oxide was suggested to be a key point to increase

  12. Selective in situ functionalization of biosensors on LOC devices using laminar co-flow

    DEFF Research Database (Denmark)

    Parra-Cabrera, C.; Sporer, C.; Rodriguez-Villareal, I.

    2012-01-01

    Many applications involving lab-on-a-chip (LOC) devices are prevented from entering the market because of difficulties to achieve mass production and impart suitable properties allowing long-term storage. To integrate biosensors on these microfluidic chips, one of the main restrictions...... is the fabrication and stability of the molecular modifications that must be performed on the surfaces of the sensors for a given application. The complexity of the problem increases exponentially when the LOC integrates several of these sensors. Here we present a system based on laminar co-flow to perform an on...

  13. Tactile-Sight: A Sensory Substitution Device Based on Distance-Related Vibrotactile Flow

    Directory of Open Access Journals (Sweden)

    Leandro Cancar

    2013-06-01

    Full Text Available Sensory substitution is a research field of increasing interest with regard to technical, applied and theoretical issues. Among the latter, it is of central interest to understand the form in which humans perceive the environment. Ecological psychology, among other approaches, proposes that we can detect higher-order informational variables (in the sense that they are defined over substantial spatial and temporal intervals that specify our interaction with the environment. When using a vibrotactile sensory substitution device, it is reasonable to ask if stimulation on the skin may be exploitable to detect higher-order variables. Motivated by this question, a portable vibrotactile sensory substitution device was built, using distance-based information as a source and driving a large number of vibrotactile actuators (72 in the reported version, 120 max. The portable device was designed to explore real environments, allowing natural unrestricted movement for the user while providing contingent real-time vibrotactile information. Two preliminary experiments were performed. In the first one, participants were asked to detect the time to contact of an approaching ball in a simulated (desktop environment. Reasonable performance was observed in all experimental conditions, including the one with only tactile stimulation. In the second experiment, a portable version of the device was used in a real environment, where participants were asked to hit an approaching ball. Participants were able to coordinate their arm movements with vibrotactile stimulation in appropriate timing. We conclude that vibrotactile flow can be generated by distance-based activation of the actuators and that this stimulation on the skin allows users to perceive time-to-contact related environmental properties.

  14. Hindered bacterial mobility in porous media flow enhances dispersion

    Science.gov (United States)

    Dehkharghani, Amin; Waisbord, Nicolas; Dunkel, Jörn; Guasto, Jeffrey

    2017-11-01

    Swimming bacteria live in porous environments characterized by dynamic fluid flows, where they play a crucial role in processes ranging from the bioremediation to the spread of infections. We study bacterial transport in a quasi-two-dimensional porous microfluidic device, which is complemented by Langevin simulations. The cell trajectories reveal filamentous patterns of high cell concentration, which result from the accumulation of bacteria in the high-shear regions of the flow and their subsequent advection. Moreover, the effective diffusion coefficient of the motile bacteria is severely hindered in the transverse direction to the flow due to decorrelation of the cells' persistent random walk by shear-induced rotation. The hindered lateral diffusion has the surprising consequence of strongly enhancing the longitudinal bacterial transport through a dispersion effect. These results demonstrate the significant role of the flow and geometry in bacterial transport through porous media with potential implications for understanding ecosystem dynamics and engineering bioreactors. NSF CBET-1511340, NSF CAREER-1554095.

  15. Lateral convection and diffusion of sediment in straight rivers

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    and a higher level of turbulence at the channel centre, than in the near bank zones, which means that the ability to support suspended sediment will decrease from the channel centre. The two turbulence models give different estimates for the lateral transport, which mainly are caused by turbulence generated......The lateral transport of suspended sediment in a straight river cross section with a parabolic shaped bed is studied be use of a k-e and a full Reynolds stress turbulence model. Due to depth variations a lateral transport of suspended sediment is generated. This is mainly caused by the slopping bed...... secondary flow cells in the Reynolds stress model. The flow cells make zones with alternately high and low sediment concentration, and thereby much higher local gradients in the lateral direction. Both models found a net inward lateral transport. The transport by convection was found more dominant than...

  16. Flow diversion in vasculitic intracranial aneurysms? Repair of giant complex cavernous carotid aneurysm in polyarteritis nodosa using Pipeline embolization devices: first reported case.

    Science.gov (United States)

    Martinez Santos, Jaime; Kaderali, Zul; Spears, Julian; Rubin, Laurence A; Marotta, Thomas R

    2016-07-01

    Intracranial aneurysms in polyarteritis nodosa (PAN) are exceedingly rare lesions with unpredictable behavior that pose real challenges to microsurgical and endovascular interventions owing to their inflammatory nature. We introduce a safe and effective alternative for treating these aneurysms using Pipeline embolization devices (PEDs). A 20-year-old man presented with diplopia, headaches, chronic abdominal pain, and weight loss. Diagnostic evaluations confirmed PAN, including bilateral giant cavernous carotid aneurysms. Cyclophosphamide and steroids achieved significant and sustained clinical improvement, with a decision to follow the aneurysms serially. Seven years later the left unruptured aneurysm enlarged, causing a sudden severe headache and a cavernous sinus syndrome. Treatment of the symptomatic aneurysm was pursued using flow diversion (PED) and the internal carotid artery was successfully reconstructed with a total of four overlapping PEDs. At 6 months follow-up, complete exclusion of the aneurysm was demonstrated, with symptomatic recovery. This is the first description of using a flow-diverting technique in an inflammatory vasculitis. In this case, PEDs not only attained a definitive closure of the aneurysm but also reconstructed the damaged and fragile arterial segment affected with vasculitis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Integration of power flow controlling devices and HVDC-systems into the optimal power flow; Integration von leistungsflusssteuernden Komponenten und HGUe-Systemen in die Leistungsflussoptimierung

    Energy Technology Data Exchange (ETDEWEB)

    Natemeyer, Hendrik; Scheufen, Martin; Roehder, Andreas; Schnettler, Armin [RWTH Aachen Univ. (Germany). Inst. fuer Hochspannungstechnik (IFHT)

    2012-07-01

    An integration of High Voltage Direct Current Transmission Systems (HVDC) or Flexible AC Transmission Systems (FACTS) into power systems enables the possibility to actively influence and control the corresponding power flows in the electrical network. The systemic benefits are a more efficient utilization of existing transmission capacities and improved controllability in fault situations. This paper introduces methods of a coordinative control of such devices and their representation in stationary power flow calculations including the control in (n-1)-cases. This might be a useful tool for the network operation, especially in face of more frequently occurring fast system changes. Examples of a corresponding implementation and application are provided. (orig.)

  18. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  19. Influence of vertical and lateral heat transfer on permafrost thaw, peatland landscape transition, and groundwater flow

    Science.gov (United States)

    Kurylyk, Barret L.; Masaki, Masaki; Quinton, William L.; McKenzie, Jeffrey M.; Voss, Clifford I.

    2016-01-01

    Recent climate change has reduced the spatial extent and thickness of permafrost in many discontinuous permafrost regions. Rapid permafrost thaw is producing distinct landscape changes in the Taiga Plains of the Northwest Territories, Canada. As permafrost bodies underlying forested peat plateaus shrink, the landscape slowly transitions into unforested wetlands. The expansion of wetlands has enhanced the hydrologic connectivity of many watersheds via new surface and near-surface flow paths, and increased streamflow has been observed. Furthermore, the decrease in forested peat plateaus results in a net loss of boreal forest and associated ecosystems. This study investigates fundamental processes that contribute to permafrost thaw by comparing observed and simulated thaw development and landscape transition of a peat plateau-wetland complex in the Northwest Territories, Canada from 1970 to 2012. Measured climate data are first used to drive surface energy balance simulations for the wetland and peat plateau. Near-surface soil temperatures simulated in the surface energy balance model are then applied as the upper boundary condition to a three-dimensional model of subsurface water flow and coupled energy transport with freeze-thaw. Simulation results demonstrate that lateral heat transfer, which is not considered in many permafrost models, can influence permafrost thaw rates. Furthermore, the simulations indicate that landscape evolution arising from permafrost thaw acts as a positive feedback mechanism that increases the energy absorbed at the land surface and produces additional permafrost thaw. The modeling results also demonstrate that flow rates in local groundwater flow systems may be enhanced by the degradation of isolated permafrost bodies.

  20. Lateral shifting in one dimensional chiral photonic crystal

    Energy Technology Data Exchange (ETDEWEB)

    You Yuan, E-mail: yctcyouyuan@163.com [School of Physics and Electronics, Yancheng Teachers University, Yancheng, 224002 Jiangsu (China); Chen Changyuan [School of Physics and Electronics, Yancheng Teachers University, Yancheng, 224002 Jiangsu (China)

    2012-07-01

    We report the lateral shifts of the transmitted waves in a one dimensional chiral photonic crystal by using the stationary-phase approach. It is revealed that two kinds of lateral shifts are observed due to the existence of cross coupling in chiral materials, which is different from what has been observed in previous non-chiral photonic crystals. Unlike the chiral slab, the positions of lateral shift peaks are closely related to the band edges of band gap characteristics of periodic structure and lateral shifts can be positive as well as negative. Besides, the lateral shifts show a strong dependence on the chiral factor, which varies the lateral shift peaks in both magnitudes and positions. These features are desirable for future device applications.

  1. Lateral shifting in one dimensional chiral photonic crystal

    International Nuclear Information System (INIS)

    You Yuan; Chen Changyuan

    2012-01-01

    We report the lateral shifts of the transmitted waves in a one dimensional chiral photonic crystal by using the stationary-phase approach. It is revealed that two kinds of lateral shifts are observed due to the existence of cross coupling in chiral materials, which is different from what has been observed in previous non-chiral photonic crystals. Unlike the chiral slab, the positions of lateral shift peaks are closely related to the band edges of band gap characteristics of periodic structure and lateral shifts can be positive as well as negative. Besides, the lateral shifts show a strong dependence on the chiral factor, which varies the lateral shift peaks in both magnitudes and positions. These features are desirable for future device applications.

  2. Rapid fabrication of pressure-driven open-channel microfluidic devices in omniphobic R(F) paper.

    Science.gov (United States)

    Glavan, Ana C; Martinez, Ramses V; Maxwell, E Jane; Subramaniam, Anand Bala; Nunes, Rui M D; Soh, Siowling; Whitesides, George M

    2013-08-07

    This paper describes the fabrication of pressure-driven, open-channel microfluidic systems with lateral dimensions of 45-300 microns carved in omniphobic paper using a craft-cutting tool. Vapor phase silanization with a fluorinated alkyltrichlorosilane renders paper omniphobic, but preserves its high gas permeability and mechanical properties. When sealed with tape, the carved channels form conduits capable of guiding liquid transport in the low-Reynolds number regime (i.e. laminar flow). These devices are compatible with complex fluids such as droplets of water in oil. The combination of omniphobic paper and a craft cutter enables the development of new types of valves and switches, such as "fold valves" and "porous switches," which provide new methods to control fluid flow.

  3. Printing-based fabrication method using sacrificial paper substrates for flexible and wearable microfluidic devices

    International Nuclear Information System (INIS)

    Chung, Daehan; Gray, Bonnie L

    2017-01-01

    We present a simple, fast, and inexpensive new printing-based fabrication process for flexible and wearable microfluidic channels and devices. Microfluidic devices are fabricated on textiles (fabric) for applications in clothing-based wearable microfluidic sensors and systems. The wearable and flexible microfluidic devices are comprised of water-insoluable screen-printable plastisol polymer. Sheets of paper are used as sacrificial substrates for multiple layers of polymer on the fabric’s surface. Microfluidic devices can be made within a short time using simple processes and inexpensive equipment that includes a laser cutter and a thermal laminator. The fabrication process is characterized to demonstrate control of microfluidic channel thickness and width. Film thickness smaller than 100 micrometers and lateral dimensions smaller than 150 micrometers are demonstrated. A flexible microfluidic mixer is also developed on fabric and successfully tested on both flat and curved surfaces at volumetric flow rates ranging from 5.5–46 ml min −1 . (paper)

  4. Printing-based fabrication method using sacrificial paper substrates for flexible and wearable microfluidic devices

    Science.gov (United States)

    Chung, Daehan; Gray, Bonnie L.

    2017-11-01

    We present a simple, fast, and inexpensive new printing-based fabrication process for flexible and wearable microfluidic channels and devices. Microfluidic devices are fabricated on textiles (fabric) for applications in clothing-based wearable microfluidic sensors and systems. The wearable and flexible microfluidic devices are comprised of water-insoluable screen-printable plastisol polymer. Sheets of paper are used as sacrificial substrates for multiple layers of polymer on the fabric’s surface. Microfluidic devices can be made within a short time using simple processes and inexpensive equipment that includes a laser cutter and a thermal laminator. The fabrication process is characterized to demonstrate control of microfluidic channel thickness and width. Film thickness smaller than 100 micrometers and lateral dimensions smaller than 150 micrometers are demonstrated. A flexible microfluidic mixer is also developed on fabric and successfully tested on both flat and curved surfaces at volumetric flow rates ranging from 5.5-46 ml min-1.

  5. An automatic enzyme immunoassay based on a chemiluminescent lateral flow immunosensor.

    Science.gov (United States)

    Joung, Hyou-Arm; Oh, Young Kyoung; Kim, Min-Gon

    2014-03-15

    Microfluidic integrated enzyme immunosorbent assay (EIA) sensors are efficient systems for point-of-care testing (POCT). However, such systems are not only relatively expensive but also require a complicated manufacturing process. Therefore, additional fluidic control systems are required for the implementation of EIAs in a lateral flow immunosensor (LFI) strip sensor. In this study, we describe a novel LFI for EIA, the use of which does not require additional steps such as mechanical fluidic control, washing, or injecting. The key concept relies on a delayed-release effect of chemiluminescence substrates (luminol enhancer and hydrogen peroxide generator) by an asymmetric polysulfone membrane (ASPM). When the ASPM was placed between the nitrocellulose (NC) membrane and the substrate pad, substrates encapsulated in the substrate pad were released after 5.3 ± 0.3 min. Using this delayed-release effect, we designed and implemented the chemiluminescent LFI-based automatic EIA system, which sequentially performed the immunoreaction, pH change, substrate release, hydrogen peroxide generation, and chemiluminescent reaction with only 1 sample injection. In a model study, implementation of the sensor was validated by measuring the high sensitivity C-reactive protein (hs-CRP) level in human serum. © 2013 Elsevier B.V. All rights reserved.

  6. Development of a Smartphone-based reading system for lateral flow immunoassay.

    Science.gov (United States)

    Lee, Sangdae; Kim, Giyoung; Moon, Jihea

    2014-11-01

    This study was conducted to develop and evaluate the performance of the Smartphone-based reading system for the lateral flow immunoassay (LFIA). Smartphone-based reading system consists of a Samsung Galaxy S2 Smartphone, Smartphone application, and a LFIA reader. LFIA reader is composed of the close-up lens with a focal length up to 30 mm, white LED light, lithium polymer battery, and main body. The Smartphone application for image acquisition and data analysis was developed on the Android platform. The standard curve was obtained by plotting the measured P(T)/P(c) or A(T)/A(c) ratio versus Salmonella standard concentration. The mean, standard deviation (SD), recovery, and relative standard deviation (RSD) were also calculated using additional experimental results. These data were compared with that obtained from the benchtop LFIA reader. The LOD in both systems was observed with 10(6) CFU/mL. The results show high accuracy and good reproducibility with a RSD less than 10% in the range of 10(6) to 10(9) CFU/mL. Due to the simple structure, good sensitivity, and high accuracy of the Smartphone-based reading system, this system can be substituted for the benchtop LFIA reader for point-of-care medical diagnostics.

  7. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  8. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Bellapart, Judith; Fraser, John F; Chan, Gregory S H; Tzeng, Yu-Chieh; Ainslie, Philip N; Dunster, Kimble R; Barnett, Adrian G; Boots, Rob

    2011-01-01

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  9. Vertical and lateral heterogeneous integration

    Science.gov (United States)

    Geske, Jon; Okuno, Yae L.; Bowers, John E.; Jayaraman, Vijay

    2001-09-01

    A technique for achieving large-scale monolithic integration of lattice-mismatched materials in the vertical direction and the lateral integration of dissimilar lattice-matched structures has been developed. The technique uses a single nonplanar direct-wafer-bond step to transform vertically integrated epitaxial structures into lateral epitaxial variation across the surface of a wafer. Nonplanar wafer bonding is demonstrated by integrating four different unstrained multi-quantum-well active regions lattice matched to InP on a GaAs wafer surface. Microscopy is used to verify the quality of the bonded interface, and photoluminescence is used to verify that the bonding process does not degrade the optical quality of the laterally integrated wells. The authors propose this technique as a means to achieve greater levels of wafer-scale integration in optical, electrical, and micromechanical devices.

  10. Can use of walkers or canes impede lateral compensatory stepping movements?

    Science.gov (United States)

    Bateni, Hamid; Heung, Evelyn; Zettel, John; McLlroy, William E; Maki, Brian E

    2004-08-01

    Although assistive devices, such as walkers and canes are often prescribed to aid in balance control, recent studies have suggested that such devices may actually increase risk of falling. In this study, we investigated one possible mechanism: the potential for walkers or canes to interfere with, or constrain, lateral movement of the feet and thereby impede execution of compensatory stepping reactions during lateral loss of balance. Lateral stepping reactions were evoked, in 10 healthy young adults (ages 22-27 years), by means of sudden unpredictable medio-lateral support surface translation. Subjects were tested while holding and loading a standard pickup walker or single-tip cane or while using no assistive device (hands free or holding an object). Results supported the hypothesis that using a walker or cane can interfere with compensatory stepping. Collisions between the swing-foot and mobility aid were remarkably frequent when using the walker (60% of stepping reactions) and also occurred in cane trials (11% of stepping reactions). Furthermore, such collisions were associated with a significant reduction (26-37%) in lateral step length. It appeared that subjects were sometimes able to avoid collision by increasing the forward or backward displacement of the swing-foot or by moving the cane; however, attempts to lift the walker out of the way occurred rarely and were usually impeded due to collision between the contralateral walker post and stance foot. The fact that compensatory stepping behavior was altered significantly in such a healthy cohort clearly demonstrates some of the safety limitations inherent to these assistive devices, as currently designed. Copyright 2003 Elsevier B.V.

  11. Effect of the left lateral recumbent position compared with the supine and upright positions on placental blood flow in normal late pregnancy.

    Science.gov (United States)

    Suonio, S; Simpanen, A L; Olkkonen, H; Haring, P

    1976-02-01

    The placental blood flow was assessed by the 99mTc accumulation method in 10 normal pregnancies in the left lateral recumbent position accomplished by a 15 degree wedge and in the supine position. The postural change caused a 17% decrease in the mean placental accumulation rate, which was not statistically significant. Ten patients were moved from the left lateral recumbent position to the upright position, which caused a statistically significant 23% decrease in the mean accumulation rate. Other haemodynamic variables studied were the maternal heart rate and the systolic and diastolic blood pressures. The clinical significance of the haemodynamic changes produced by alterations in posture are briefly discussed.

  12. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  13. Relations between neuropsychological findings and lateral asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Yoshimura, Nahoko; Soma, Yoshiaki; Ootsuki, Mika

    1993-01-01

    We studied 16 right-handed patients clinically diagnosed as dementia of Alzheimer type (6 men, 10 women; aged 63-85, mean 72.8 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebrovascular disease (Hachinski ischemic scores for all patients were 4 or below 4). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow (rCBF) was evaluated by single photon emission CT (SPECT) with 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP), using the Matsuda's quantitative method. Regional tracer uptake was measured in regions of interests (ROIs) over right and left frontal, temporal, parietal and occipital cortical regions; basal ganglia; and cerebellar hemispheres. The subjects were divided into three groups on the basis of lateral asymmetries in the temporal and parietal cortexes of rCBF (left< right, n=5; right< left, n=3; left=right, n=8). We decided that lateral asymmetry was present when rCBF for each ROI between left and right sides differs by more than 10%. General score (MMS, T-IQ) was not correlated with asymmetry of cerebral blood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe was significantly lower than other group, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. Decreased rCBF in the left temporoparietal lobe was associated with language dysfunction, and that in the right hemisphere, with constructive dysfunction. (author)

  14. Relations between neuropsychological findings and lateral asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Nahoko; Soma, Yoshiaki; Ootsuki, Mika [Takeda General Hospital, Aizu-Wakamatsu, Fukushima (Japan)

    1993-10-01

    We studied 16 right-handed patients clinically diagnosed as dementia of Alzheimer type (6 men, 10 women; aged 63-85, mean 72.8 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebrovascular disease (Hachinski ischemic scores for all patients were 4 or below 4). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow (rCBF) was evaluated by single photon emission CT (SPECT) with {sup 123}I-N-isopropyl-p-iodoamphetamine ({sup 123}I-IMP), using the Matsuda`s quantitative method. Regional tracer uptake was measured in regions of interests (ROIs) over right and left frontal, temporal, parietal and occipital cortical regions; basal ganglia; and cerebellar hemispheres. The subjects were divided into three groups on the basis of lateral asymmetries in the temporal and parietal cortexes of rCBF (leftlateral asymmetry was present when rCBF for each ROI between left and right sides differs by more than 10%. General score (MMS, T-IQ) was not correlated with asymmetry of cerebral blood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe was significantly lower than other group, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. Decreased rCBF in the left temporoparietal lobe was associated with language dysfunction, and that in the right hemisphere, with constructive dysfunction. (author).

  15. Peripheral Artery Disease and Continuous Flow Left Ventricle Assist Device: An Engaging Complement Analysis May Help to Guide Treatment.

    Science.gov (United States)

    Falletta, Calogero; Pasta, Salvatore; Raffa, Giuseppe Maria; Crinò, Francesca; Sciacca, Sergio; Clemenza, Francesco

    2018-02-13

    Use of continuous flow left ventricle assist device (CF-LVAD) in advanced heart failure (HF) patients results in clinically relevant improvements in survival, functional capacity, and quality of life. Peripheral artery disease (PAD) can occur in patients with CF-LVAD due to the high rate of concomitance between risk factors for atherosclerosis and HF. Diagnosis of PAD can be difficult in the specific setting of a patient supported by this kind of device because of the marked alteration in waveform morphology and velocity created by the artificial physiology of an LVAD. We report the case of a 53-year-old man with HF secondary to ischemic cardiomyopathy supported by the HeartWare HVAD as bridge to transplant, who after the implant developed symptoms suggestive of PAD. We describe additional computational flow analysis for the study of PAD-related hemodynamic disturbances induced by a CF-LVAD. Flow simulations enhance the information of clinical image data, and may have an application in clinical investigations of the risk of hemodynamic disturbances induced by LVAD implantation. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Impact of Thyristors Controlled Series Capacitor Devices and Optimal Power Flow on Power Systems

    Directory of Open Access Journals (Sweden)

    Fatiha LAKDJA

    2010-12-01

    Full Text Available This paper presents an algorithm, for solving the Optimal Power Flow problem with flexible AC transmission systems (FACTS. The type of FACTS devices is used: thyristor-controlled series capacitor (TCSC. A method to determine the optimal location of thyristor controlled series compensators has been suggested. The proposed approaches have been implemented on an adapted IEEE 26 bus system. The simulation results are discussed to show the performance of the proposed algorithm and our “FACTS programmer “simulator technique, which are compared with TCSC and without TCSC.

  17. Comparison of Lateral Flow Assay, Kidney Inhibition Swab, and Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Penicillin G Residues in Sow Urine.

    Science.gov (United States)

    Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J

    2017-03-01

    Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.

  18. CPAP Devices for Emergency Prehospital Use: A Bench Study.

    Science.gov (United States)

    Brusasco, Claudia; Corradi, Francesco; De Ferrari, Alessandra; Ball, Lorenzo; Kacmarek, Robert M; Pelosi, Paolo

    2015-12-01

    CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions. Copyright © 2015 by Daedalus Enterprises.

  19. Dielectrokinetic chromatography and devices thereof

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-04-22

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  20. Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay

    Science.gov (United States)

    Serebrennikova, Kseniya; Samsonova, Jeanne; Osipov, Alexander

    2018-06-01

    Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5-10 ng mL-1 with the limit of detection of 0.1 ng mL-1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies).

  1. Continuous Hydrothermal Flow Synthesis of Functional Oxide Nanomaterials Used in Energy Conversion Devices

    DEFF Research Database (Denmark)

    Xu, Yu

    Continuous hydrothermal flow synthesis (CHFS) was used to prepare functional oxide nanoparticles. Materials synthesized include NiO, Y-doped ZrO2, Gd-doped CeO2, LaCrO3 and Ni-substituted CoFe2O4. These types of oxides can be applied in several energy conversion devices, e.g. as active materials...... as materials are continuously produced, and the technology can be scaled-up to an industrial-relevant production capacity. The thesis starts with investigating the most appropriate mixer design for a novel two-stage reactor by computational fluid dynamics modelling. On basis of the modelling results, a two......, dense continuous layers (

  2. Successful 1:1 proportion ventilation with a unique device for independent lung ventilation using a double-lumen tube without complications in the supine and lateral decubitus positions. A pilot study.

    Directory of Open Access Journals (Sweden)

    Michał Kowalczyk

    Full Text Available Adequate blood oxygenation and ventilation/perfusion matching should be main goal of anaesthetic and intensive care management. At present, one of the methods of improving gas exchange restricted by ventilation/perfusion mismatching is independent ventilation with two ventilators. Recently, however, a unique device has been developed, enabling ventilation of independent lungs in 1:1, 2:1, 3:1, and 5:1 proportions. The main goal of the study was to evaluate the device's utility, precision and impact on pulmonary mechanics. Secondly- to measure the gas distribution in supine and lateral decubitus position.69 patients who underwent elective thoracic surgery were eligible for the study. During general anaesthesia, after double lumen tube intubation, the aforementioned control system was placed between the anaesthetic machine and the patient. In the supine and lateral decubitus (left/right positions, measurements of conventional and independent (1:1 proportion ventilation were performed separately for each lung, including the following: tidal volume, peak pressure and dynamic compliance.Our results show that conventional ventilation using Robertshaw tube in the supine position directs 47% of the tidal volume to the left lung and 53% to the right lung. Furthermore, in the left lateral position, 44% is directed to the dependent lung and 56% to the non-dependent lung. In the right lateral position, 49% is directed to the dependent lung and 51% to the non-dependent lung. The control system positively affected non-dependent and dependent lung ventilation by delivering equal tidal volumes into both lungs with no adverse effects, regardless of patient's position.We report that gas distribution is uneven during conventional ventilation using Robertshaw tube in the supine and lateral decubitus positions. However, this recently released control system enables precise and safe independent ventilation in the supine and the left and right lateral decubitus

  3. Performance of Installed Cooking Exhaust Devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Delp, William W.; Apte, Michael G.; Price, Philip N.

    2011-11-01

    The performance metrics of airflow, sound, and combustion product capture efficiency (CE) were measured for a convenience sample of fifteen cooking exhaust devices, as installed in residences. Results were analyzed to quantify the impact of various device- and installation-dependent parameters on CE. Measured maximum airflows were 70% or lower than values noted on product literature for 10 of the devices. Above-the-cooktop devices with flat bottom surfaces (no capture hood) – including exhaust fan/microwave combination appliances – were found to have much lower CE at similar flow rates, compared to devices with capture hoods. For almost all exhaust devices and especially for rear-mounted downdraft exhaust and microwaves, CE was substantially higher for back compared with front burner use. Flow rate, and the extent to which the exhaust device extends over the burners that are in use, also had a large effect on CE. A flow rate of 95 liters per second (200 cubic feet per minute) was necessary, but not sufficient, to attain capture efficiency in excess of 75% for the front burners. A-weighted sound levels in kitchens exceeded 57 dB when operating at the highest fan setting for all 14 devices evaluated for sound performance.

  4. Baking exhaustion device in thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Mitsunori.

    1987-02-02

    Purpose: To rapidly remove tritium and impurity from the vacuum region in the access port of the baking exhaustion device in a thermonuclear device. Constitution: Each of the gaps at the boundary between a fixed shielding member and a blanket module and at the boundary between the blanket and a divertor is made extremely small so as to minimize the neutron streaming from plasmas. Accordingly, in the case of evacuating the vacuum region in the access port, the gap conductance is extremely poor and the exhaustion speed is low. Then, baking pipeways for flowing high temperature fluids are embedded to the surface layer at the position facing to the vacuum region and the plasma evacuation duct and the vacuum region are connected with an evacuation duct of the access port. By flowing high temperature fluids in the pipeways and conducting evacuation, baking exhaustion can be carried out rapidly. (Kamimura, M.).

  5. Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhou, Geng; Su, Ming; Yin, Yan-Ling; Li, Ming-Hua

    2017-06-01

    OBJECTIVE The objective of this study was to review the literature on the use of flow-diverting devices (FDDs) to treat intracranial aneurysms (IAs) and to investigate the safety and complications related to FDD treatment for IAs by performing a meta-analysis of published studies. METHODS A systematic electronic database search was conducted using the Springer, EBSCO, PubMed, Medline, and Cochrane databases on all accessible articles published up to January 2016, with no restriction on the publication year. Abstracts, full-text manuscripts, and the reference lists of retrieved articles were analyzed. Random-effects meta-analysis was used to pool the complication rates across studies. RESULTS Sixty studies were included, which involved retrospectively collected data on 3125 patients. The use of FDDs was associated with an overall complication rate of 17.0% (95% confidence interval [CI] 13.6%-20.5%) and a low mortality rate of 2.8% (95% CI 1.2%-4.4%). The neurological morbidity rate was 4.5% (95% CI 3.2%-5.8%). No significant difference in the complication or mortality rate was observed between 2 commonly used devices (the Pipeline embolization device and the Silk flow-diverter device). A significantly higher overall complication rate was found in the case of ruptured IAs than in unruptured IA (odds ratio 2.3, 95% CI 1.2-4.3). CONCLUSIONS The use of FDDs in the treatment of IAs yielded satisfactory results with regard to complications and the mortality rate. The risk of complications should be considered when deciding on treatment with FDDs. Further studies on the mechanism underlying the occurrence of adverse events are required.

  6. InP Devices For Millimeter-Wave Monolithic Circuits

    Science.gov (United States)

    Binari, S. C.; Neidert, R. E.; Dietrich, H. B.

    1989-11-01

    High efficiency, mm-wave operation has been obtained from lateral transferred-electron devices (TEDs) designed with a high resistivity region located near the cathode contact. At 29.9 GHz, a CW power output of 29.1 mW with a conversion efficiency of 6.7% has been achieved with cavity-tuned discrete devices. This result represents the highest power output and efficiency of a lateral TED in this frequency range. The lateral devices also had a CW power output of 0.4 mW at 98.5 GHz and 0.9 mW at 75.2 GHz. In addition, a monolithic oscillator incorporating the lateral TED has been demonstrated at 79.9 GHz. InP Schottky-barrier diodes have been fabricated using selective MeV ion implantation into semi-insulating InP substrates. Using Si implantation with energies of up to 6.0 MeV, n+ layers as deep as 3 μm with peak carrier concentrations of 2 x 1018 cm-3 have been obtained. These devices have been evaluated as mixers and detectors at 94 GHz and have demonstrated a conversion loss of 7.6 dB and a zero-bias detector sensitivity as high as 400 mV/mW.

  7. A novel symbiotic organisms search algorithm for optimal power flow of power system with FACTS devices

    Directory of Open Access Journals (Sweden)

    Dharmbir Prasad

    2016-03-01

    Full Text Available In this paper, symbiotic organisms search (SOS algorithm is proposed for the solution of optimal power flow (OPF problem of power system equipped with flexible ac transmission systems (FACTS devices. Inspired by interaction between organisms in ecosystem, SOS algorithm is a recent population based algorithm which does not require any algorithm specific control parameters unlike other algorithms. The performance of the proposed SOS algorithm is tested on the modified IEEE-30 bus and IEEE-57 bus test systems incorporating two types of FACTS devices, namely, thyristor controlled series capacitor and thyristor controlled phase shifter at fixed locations. The OPF problem of the present work is formulated with four different objective functions viz. (a fuel cost minimization, (b transmission active power loss minimization, (c emission reduction and (d minimization of combined economic and environmental cost. The simulation results exhibit the potential of the proposed SOS algorithm and demonstrate its effectiveness for solving the OPF problem of power system incorporating FACTS devices over the other evolutionary optimization techniques that surfaced in the recent state-of-the-art literature.

  8. Effect of magnetic attachment with stress breaker on lateral stress to abutment tooth under overdenture.

    Science.gov (United States)

    Gonda, T; Ikebe, K; Ono, T; Nokubi, T

    2004-10-01

    Recently, a newly developed magnetic attachment with stress breaker was used in retentive components in overdentures. Excessive lateral stress has a more harmful effect on natural teeth than axial stress, and the magnetic attachment with stress breaker is expected to reduce lateral forces on abutment teeth and protect it teeth from excessive stress. However, the properties of this retainer have not yet been determined experimentally. This study compares the lateral forces on abutment teeth for three retainers under loading on the denture base in a model study. A mandibular simulation model is constructed to measure lateral stress. Three types of retentive devices are attached to the canine root. These devices include the conventional root coping, the conventional magnetic attachment and the new magnetic attachment with stress breaker. For each retentive device, load is generated on the occlusal table of the model overdenture, and the lateral stress on the canine root and the displacement of the overdenture measured. The magnetic attachment with stress breaker does not displace the denture and exhibits lower lateral stress in the canine root than conventional root coping and magnetic attachments.

  9. Usefulness of DC power flow for active power flow analysis with flow controlling devices

    NARCIS (Netherlands)

    Van Hertem, D.; Verboomen, J.; Purchala, K.; Belmans, R.; Kling, W.L.

    2006-01-01

    DC power flow is a commonly used tool for contingency analysis. Recently, due to its simplicity and robustness, it also becomes increasingly used for the real-time dispatch and techno-economic analysis of power systems. It is a simplification of a full power flow looking only at active power.

  10. Design and fabrication of forced-flow superconducting poloidal coils for the Large Helical Device

    International Nuclear Information System (INIS)

    Nakamoto, K.; Yamamoto, T.; Mizumaki, S.; Yamakoshi, T.; Kanai, Y.; Yamamoto, K.; Wachi, Y.; Ushijima, M.; Yoshida, T.; Kai, T.; Takahata, K.; Yamamoto, J.; Satow, T.; Motojima, O.

    1995-01-01

    Three pairs of superconducting poloidal coils for the LHD (Large Helical Device) have been designed and fabricated using NbTi/Cu cable-in-conduit (CIC) conductors cooled with forced-flow supercritical helium (SHE). In the LHD poloidal coils, high field accuracy as well as high reliability are required. To meet these requirements, detailed field and structural analyses have been performed and key parameters including winding pattern and size and locations of conductor joints have been determined. Compact conductor joint, where NbTi filaments are directly bonded, has also been developed using the solid state bonding technique. (orig.)

  11. Centrifuge modelling of lateral displacement of buried pipelines; Modelagem fisica centrifuga de flambagem lateral de dutos

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jose Renato Moreira da Silva de; Almeida, Marcio de Souza Soares de; Marques, Maria Esther Soares; Almeida, Maria Cascao Ferreira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE); Costa, Alvaro Maia da [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2003-07-01

    This work discusses soil-structure interaction applied to the buckling phenomena of buried pipelines subjected to heated oil flow. A set of physical modelling tests on lateral buckling of pipelines buried on soft clay is presented using COPPE/UFRJ geotechnical centrifuge. A 1:30 pipeline model was moved side ward through a soft clay layer during centrifuge flight, varying the burial depth, in order to simulate the lateral buckling in plane strain condition. The results show different behaviour concerning horizontal and vertical forces measured at pipeline level due to soil reaction. (author)

  12. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  13. Dynamical phase separation using a microfluidic device: experiments and modeling

    Science.gov (United States)

    Aymard, Benjamin; Vaes, Urbain; Radhakrishnan, Anand; Pradas, Marc; Gavriilidis, Asterios; Kalliadasis, Serafim; Complex Multiscale Systems Team

    2017-11-01

    We study the dynamical phase separation of a binary fluid by a microfluidic device both from the experimental and from the modeling points of view. The experimental device consists of a main channel (600 μm wide) leading into an array of 276 trapezoidal capillaries of 5 μm width arranged on both sides and separating the lateral channels from the main channel. Due to geometrical effects as well as wetting properties of the substrate, and under well chosen pressure boundary conditions, a multiphase flow introduced into the main channel gets separated at the capillaries. Understanding this dynamics via modeling and numerical simulation is a crucial step in designing future efficient micro-separators. We propose a diffuse-interface model, based on the classical Cahn-Hilliard-Navier-Stokes system, with a new nonlinear mobility and new wetting boundary conditions. We also propose a novel numerical method using a finite-element approach, together with an adaptive mesh refinement strategy. The complex geometry is captured using the same computer-aided design files as the ones adopted in the fabrication of the actual device. Numerical simulations reveal a very good qualitative agreement between model and experiments, demonstrating also a clear separation of phases.

  14. The pharmacotherapy of the HeartMate II, a continuous flow left ventricular assist device, in patients with advanced heart failure: integration of disease, device, and drug.

    Science.gov (United States)

    Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M

    2010-10-01

    Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.

  15. Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite

    Directory of Open Access Journals (Sweden)

    Zhao Y

    2017-07-01

    Full Text Available Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE with well clinical relevance to house dust mite (HDM are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE 

  16. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    Science.gov (United States)

    Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas

    2015-01-01

    The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  17. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    Science.gov (United States)

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid

    2009-04-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  18. The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays.

    Science.gov (United States)

    Zhan, Li; Guo, Shuang-Zhuang; Song, Fayi; Gong, Yan; Xu, Feng; Boulware, David R; McAlpine, Michael C; Chan, Warren C W; Bischof, John C

    2017-12-13

    Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.

  19. Towards 2D field-flow fractionation - Vector separation over slanted open cavities

    Science.gov (United States)

    Bernate, Jorge A.; Yang, Mengfei; Zhao, Hong; Risbud, Sumedh; Paul, Colin; Dallas, Matthew; Konstantopoulos, Konstantinos; Drazer, German; Shaqfeh, Eric S. G.

    2013-11-01

    Planar microfluidic platforms for vector chromatography, in which different species fan out in different directions and can be continuously sorted, are particularly promising for the high throughput separation of multicomponent mixtures. We carry out a computational study of the vector separation of dilute suspensions of rigid and flexible particles transported by a pressure-driven flow over an array of slanted open cavities. The numerical scheme is based on a Stokes flow boundary integral equation method. The simulations are performed in a periodic system without lateral confinement, relevant to microfluidic devices with negligible recirculation in the main channel. We study the deflection of rigid spherical particles, of flexible capsules as a model of white and red blood cells, and of rigid discoidal particles as a model of platelets. We characterize the deflection of different particles as a function of their size, shape, shear elasticity, their release position, and the geometric parameters of the channel. The simulations provide insight into the separation mechanism and allow the optimization of specific devices depending on the application. Good agreement with experiments is observed.

  20. Hidden (end-on) patent ductus arteriosus: recognition and device closure.

    Science.gov (United States)

    Garg, Naveen; Madan, Bevunahalli Kantharaj

    2016-02-01

    Sometimes, it is difficult to visualize a patent ductus arteriosus and deploy a device in the standard lateral view because of an end-on orientation. The right anterior oblique view may be helpful by separating the ductus arteriosus from the aorta. This study was undertaken to evaluate the incidence of end-on patent ductus arteriosus and the utility of the right anterior oblique view during device closure. Aortography was performed in lateral and right anterior oblique views before, during, and after successful device deployment in 117 consecutive patients. When a ductus arteriosus was not clearly visible in the lateral view due to overlapping by the aorta, it was termed "right anterior oblique view useful". The types of patent ductus arteriosus were A, B, C, and E in 86 (73.5%), 20 (17.1%), 4 (3.4%), and 7 (6.0%) patients, respectively. An end-on ductus arteriosus was present in 24 (20.5%) patients (14 type B, 10 type A). The right anterior oblique view was useful during device closure in 15 (12.8%) cases (all end-on type). Among all cases of end-on patent ductus arteriosus, it was useful in 62.5% (most type B and a few type A). In all of these, the device appeared obliquely oriented and foreshortened in the lateral view but fully profiled in the right anterior oblique view. Recognizing an end-on patent ductus arteriosus and utilizing the right anterior oblique view simplified device closure. For ducts well-profiled in the lateral view, the right anterior oblique view is unnecessary and avoidable. © The Author(s) 2016.

  1. Comparative X-ray investigation of lateral and anterior-posterior ankle-joint images - comparison with pathological and anatomical findings concerning lateral ankle-joint lesions and their clinical importance, studied in a special type of holding device

    International Nuclear Information System (INIS)

    John, F.

    1982-01-01

    The study reports on a possibility to interpret the relation of the different bone structures of the upper ankle-joint to one another in the X-ray picture without using contrast media. Modern funtional diagnostic methods increasingly make use of X-ray pictures taken in fixed position. It seems useful to standardize such X-ray images of the ankle-joint in order to make them reproducible. The author developed a device that would suit these purposes. A diagnosis required the reproduction of the accidental mechanism. The clinical symptoms do not permit to clearly state the extent of the lesion of the ligaments. The results of the post-operative follow-up examinations confirm the urgent necessity of the standardized diagnostic method presented and the success of the therapy applied. The presented X-ray method permits safe diagnosis of ruptures of the ligaments. Location of a certain rupture is not possible with the fixed-position X-ray screening. For a clear assessment of lesions of the ligaments at the lateral ankle-joint, X-ray pictures must be taken both in the anterior-posterior path of rays and in the lateral one. A normal result in the lateral path of rays does not exclude a pathologic result in the anterior-posterior path of rays, and vice versa. (orig./MG) [de

  2. The in situ permeable flow sensor: A device for measuring groundwater flow velocity

    International Nuclear Information System (INIS)

    Ballard, S.; Barker, G.T.; Nichols, R.L.

    1994-03-01

    A new technology called the In Situ Permeable Flow Sensor has been developed at Sandia National Laboratories. These sensors use a thermal perturbation technique to directly measure the direction and magnitude of the full three dimensional groundwater flow velocity vector in unconsolidated, saturated, porous media. The velocity measured is an average value characteristic of an approximately 1 cubic meter volume of the subsurface. During a test at the Savannah River Site in South Carolina, two flow sensors were deployed in a confined aquifer in close proximity to a well which was screened over the entire vertical extent of the aquifer and the well was pumped at four different pumping rates. In this situation horizontal flow which is radially directed toward the pumping well is expected. The flow sensors measured horizontal flow which was directed toward the pumping well, within the uncertainty in the measurements. The observed magnitude of the horizontal component of the flow velocity increased linearly with pumping rate, as predicted by theoretical considerations. The measured horizontal component of the flow velocity differed from the predicted flow velocity, which was calculated with the assumptions that the hydraulic properties of the aquifer were radially homogeneous and isotropic, by less than a factor of two. Drawdown data obtained from other wells near the pumping well during the pump test indicate that the hydraulic properties of the aquifer are probably not radially homogeneous but the effect of the inhomogeneity on the flow velocity field around the pumping well was not modeled because the degree and distribution of the inhomogeneity are unknown. Grain size analysis of core samples from wells in the area were used to estimate the vertical distribution of hydraulic conductivity

  3. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  4. Lateral flow assay for rapid detection of white spot syndrome virus (WSSV) using a phage-displayed peptide as bio-recognition probe.

    Science.gov (United States)

    Kulabhusan, Prabir Kumar; Rajwade, Jyutika M; Sahul Hameed, A S; Paknikar, Kishore M

    2017-06-01

    White spot disease caused by the white spot syndrome virus (WSSV) has a major socio-economic impact on shrimp farming in India. It has been realized that a field-usable diagnostic capable of rapid detection of WSSV can prevent huge economic losses in disease outbreaks. In this work, we explored the possibility of using a peptide as bio-recognition probe in a field-usable device for the detection of WSSV from infected shrimps and prawns. A commercially available random phage-display library was screened against rVP28 (a major structural protein of WSSV, expressed as a recombinant protein in Escherichia coli). A bacteriophage clone VP28-4L was obtained, and its binding to purified rVP28 protein as well as WSSV from infected shrimp Litopaeneus vannamei tissue was confirmed by ELISA and western blot. The apparent equilibrium dissociation constant (K d ,app) was calculated to be 810 nM. VP28-4L did not show cross-reactivity with any other shrimp viruses. A 12-mer peptide (pep28, with the sequence 'TFQAFDLSPFPS') displayed on the VP28-4L was synthesized, and its diagnostic potential was evaluated in a lateral flow assay (LFA). Visual detection of WSSV could be achieved using biotinylated-pep28 and streptavidin-conjugated gold nanoparticles. In LFA, 12.5 μg/mL of the virus could be detected from L. vannamei gill tissue homogenate within 20 min. Pep28 thus becomes an attractive candidate in bio-recognition of WSSV in field-usable diagnostic platforms benefitting the aquaculture sector.

  5. On generation of Alfvenic-like fluctuations by drift wave-zonal flow system in large plasma device experiments

    International Nuclear Information System (INIS)

    Horton, W.; Correa, C.; Chagelishvili, G. D.; Avsarkisov, V. S.; Lominadze, J. G.; Perez, J. C.; Kim, J.-H.; Carter, T. A.

    2009-01-01

    According to recent experiments, magnetically confined fusion plasmas with ''drift wave-zonal flow turbulence'' (DW-ZF) give rise to broadband electromagnetic waves. Sharapov et al. [Europhysics Conference Abstracts, 35th EPS Conference on Plasma Physics, Hersonissos, 2008, edited by P. Lalousis and S. Moustaizis (European Physical Society, Switzerland, 2008), Vol. 32D, p. 4.071] reported an abrupt change in the magnetic turbulence during L-H transitions in Joint European Torus [P. H. Rebut and B. E. Keen, Fusion Technol. 11, 13 (1987)] plasmas. A broad spectrum of Alfvenic-like (electromagnetic) fluctuations appears from ExB flow driven turbulence in experiments on the large plasma device (LAPD) [W. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)] facility at UCLA. Evidence of the existence of magnetic fluctuations in the shear flow region in the experiments is shown. We present one possible theoretical explanation of the generation of electromagnetic fluctuations in DW-ZF systems for an example of LAPD experiments. The method used is based on generalizing results on shear flow phenomena from the hydrodynamics community. In the 1990s, it was realized that fluctuation modes of spectrally stable nonuniform (sheared) flows are non-normal. That is, the linear operators of the flows modal analysis are non-normal and the corresponding eigenmodes are not orthogonal. The non-normality results in linear transient growth with bursts of the perturbations and the mode coupling, which causes the generation of electromagnetic waves from the drift wave-shear flow system. We consider shear flow that mimics tokamak zonal flow. We show that the transient growth substantially exceeds the growth of the classical dissipative trapped-particle instability of the system.

  6. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  7. Cooling of superconducting devices by liquid storage and refrigeration unit

    Science.gov (United States)

    Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene

    2013-08-20

    A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.

  8. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    Directory of Open Access Journals (Sweden)

    Snorri Donaldsson

    Full Text Available The ability to determine airflow during nasal CPAP (NCPAP treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing.Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically.The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance.The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  9. Organizations Utilize Lateral Relationships

    OpenAIRE

    Jacqueline C.

    2017-01-01

    The structures that subscribe to different organization play a major role and determine how information flows throughout an organization as well as the reporting structure within the organization. In some organization, decision making rely with the top management, and in other organizations, decision making responsibilities may be distributed within the organization. The latter part is what mainly constitutes a lateral structural arrangement where various departments work hand in hand in achi...

  10. Fully automatic flow-based device for monitoring of drug permeation across a cell monolayer.

    Science.gov (United States)

    Zelená, Lucie; Marques, Sara S; Segundo, Marcela A; Miró, Manuel; Pávek, Petr; Sklenářová, Hana; Solich, Petr

    2016-01-01

    A novel flow-programming setup based on the sequential injection principle is herein proposed for on-line monitoring of temporal events in cell permeation studies. The permeation unit consists of a Franz cell with its basolateral compartment mixed under mechanical agitation and thermostated at 37 °C. The apical compartment is replaced by commercially available Transwell inserts with a precultivated cell monolayer. The transport of drug substances across epithelial cells genetically modified with the P-glycoprotein membrane transporter (MDCKII-MDR1) is monitored on-line using rhodamine 123 as a fluorescent marker. The permeation kinetics of the marker is obtained in a fully automated mode by sampling minute volumes of solution from the basolateral compartment in short intervals (10 min) up to 4 h. The effect of a P-glycoprotein transporter inhibitor, verapamil as a model drug, on the efficiency of the marker transport across the cell monolayer is thoroughly investigated. The analytical features of the proposed flow method for cell permeation studies in real time are critically compared against conventional batch-wise procedures and microfluidic devices.

  11. Recombinase polymerase amplification (RPA) combined with lateral flow (LF) strip for detection of Toxoplasma gondii in the environment.

    Science.gov (United States)

    Wu, Y D; Xu, M J; Wang, Q Q; Zhou, C X; Wang, M; Zhu, X Q; Zhou, D H

    2017-08-30

    Toxoplasma gondii infects all warm-blooded vertebrates, resulting in a great threat to human health and significant economic loss to the livestock industry. Ingestion of infectious oocysts of T. gondii from the environment is the major source of transmission. Detection of T. gondii oocysts by existing methods is laborious, time-consuming and expensive. The objective of the present study was to develop a recombinase polymerase amplification (RPA) method combined with a lateral flow (LF) strip for detection of T. gondii oocysts in the soil and water. The DNA of T. gondii oocysts was amplified by a pair of specific primers based on the T. gondii B1 gene over 15min at a constant temperature ranging from 30°C to 45°C using RPA. The amplification product was visualized by the lateral flow (LF) strip within 5min using the specific probe added to the RPA reaction system. The sensitivity of the established assay was 10 times higher than that of nested PCR with a lower detection limit of 0.1 oocyst per reaction, and there was no cross-reactivity with other closely related protozoan species. Fifty environmental samples were further assessed for the detection validity of the LF-RPA assay (B1-LF-RPA) and compared with nested PCR based on the B1 gene sequence. The B1-LF-RPA and nested PCR both showed that 5 out of the 50 environmental samples were positive. The B1-LF-RPA method was also proven to be sufficiently tolerant of existing inhibitors in the environment. In addition, the advantages of simple operation, speediness and cost-effectiveness make B1-LF-RPA a promising molecular detection tool for T. gondii. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Spill-Detector-and-Shutoff Device

    Science.gov (United States)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  13. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network

    OpenAIRE

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network i...

  14. Evaluation of flow hood measurements for residential register flows; TOPICAL

    International Nuclear Information System (INIS)

    Walker, I.S.; Wray, C.P.; Dickerhoff, D.J.; Sherman, M.H.

    2001-01-01

    Flow measurement at residential registers using flow hoods is becoming more common. These measurements are used to determine if the HVAC system is providing adequate comfort, appropriate flow over heat exchangers and in estimates of system energy losses. These HVAC system performance metrics are determined by using register measurements to find out if individual rooms are getting the correct airflow, and in estimates of total air handler flow and duct air leakage. The work discussed in this paper shows that commercially available flow hoods are poor at measuring flows in residential systems. There is also evidence in this and other studies that flow hoods can have significant errors even when used on the non-residential systems they were originally developed for. The measurement uncertainties arise from poor calibrations and the sensitivity of exiting flow hoods to non-uniformity of flows entering the device. The errors are usually large-on the order of 20% of measured flow, which is unacceptably high for most applications. Active flow hoods that have flow measurement devices that are insensitive to the entering airflow pattern were found to be clearly superior to commercially available flow hoods. In addition, it is clear that current calibration procedures for flow hoods may not take into account any field application problems and a new flow hood measurement standard should be developed to address this issue

  15. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  16. Force determination in lateral magnetic tweezers combined with TIRF microscopy† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7nr07344e

    Science.gov (United States)

    Madariaga-Marcos, J.; Hormeño, S.; Pastrana, C. L.; Fisher, G. L. M.; Dillingham, M. S.

    2018-01-01

    Combining single-molecule techniques with fluorescence microscopy has attracted much interest because it allows the correlation of mechanical measurements with directly visualized DNA : protein interactions. In particular, its combination with total internal reflection fluorescence microscopy (TIRF) is advantageous because of the high signal-to-noise ratio this technique achieves. This, however, requires stretching long DNA molecules across the surface of a flow cell to maximize polymer exposure to the excitation light. In this work, we develop a module to laterally stretch DNA molecules at a constant force, which can be easily implemented in regular or combined magnetic tweezers (MT)–TIRF setups. The pulling module is further characterized in standard flow cells of different thicknesses and glass capillaries, using two types of micrometer size superparamagnetic beads, long DNA molecules, and a home-built device to rotate capillaries with mrad precision. The force range achieved by the magnetic pulling module was between 0.1 and 30 pN. A formalism for estimating forces in flow-stretched tethered beads is also proposed, and the results compared with those of lateral MT, demonstrating that lateral MT achieve higher forces with lower dispersion. Finally, we show the compatibility with TIRF microscopy and the parallelization of measurements by characterizing DNA binding by the centromere-binding protein ParB from Bacillus subtilis. Simultaneous MT pulling and fluorescence imaging demonstrate the non-specific binding of BsParB on DNA under conditions restrictive to condensation. PMID:29461549

  17. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  18. Study of epitaxial lateral overgrowth of GaN for application in the fabrication of optoelectronic devices

    Science.gov (United States)

    Berry Ann, N. J.; Rodak, L. E.; Kasarla, Kalyan; Yang, Nanying; Korakakis, D.

    2005-10-01

    In this research effort, epitaxial lateral overgrowth (ELOG) of GaN on sapphire was performed by low-pressure metalorganic chemical vapor deposition (MOCVD) in a horizontal reactor. All ELOG growths were stopped prior to complete coalescence, and the resulting cross-sections were characterized by scanning electron microscopy (SEM). Both vertical {1120} and inclined sidewalls were observed. Inclined {112n}sidewalls of various angles (n 2-2.2) were found as previously reported in the literature1. Both one-step and two-step ELOG processes were used to control the overgrowth geometry. It was confirmed that sidewall formation and growth rates are closely correlated with multiple parameters including temperature and V/III ratio1. It was also found that substrate rotation greatly influences sidewall evolution and vertical growth rate. A conceptual model was begun to completely describe the ELOG process in a horizontal reactor. It is speculated that the different sidewalls observed as a function of substrate orientation result from variation in the local V/III ratio. Once developed, the final model will be used to control the sidewalls in the growth of ELOG structures for the fabrication of novel optoelectronic devices.

  19. Combining Electro-Osmotic Flow and FTA® Paper for DNA Analysis on Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ryan Wimbles

    2016-07-01

    Full Text Available FTA® paper can be used to protect a variety of biological samples prior to analysis, facilitating ease-of-transport to laboratories or long-term archive storage. The use of FTA® paper as a solid phase eradicates the need to elute the nucleic acids from the matrix prior to DNA amplification, enabling both DNA purification and polymerase chain reaction (PCR-based DNA amplification to be performed in a single chamber on the microfluidic device. A disc of FTA® paper, containing a biological sample, was placed within the microfluidic device on top of wax-encapsulated DNA amplification reagents. The disc containing the biological sample was then cleaned up using Tris-EDTA (TE buffer, which was passed over the disc, via electro-osmotic flow, in order to remove any potential inhibitors of downstream processes. DNA amplification was successfully performed (from buccal cells, whole blood and semen using a Peltier thermal cycling system, whereupon the stored PCR reagents were released during the initial denaturing step due to the wax barrier melting between the FTA® disc and PCR reagents. Such a system offers advantages in terms of a simple sample introduction interface and the ability to process archived samples in an integrated microfluidic environment with minimal risk of contamination.

  20. Laparoscopic left lateral sectionectomy with the use of Habib 4X: technical aspects.

    Science.gov (United States)

    Zacharoulis, Dimitris; Sioka, Eleni; Tzovaras, George; Jiao, Long R; Habib, Nagy

    2013-06-01

    Various techniques and energy-based devices have been used to minimize the blood loss during transection of the liver parenchyma laparoscopically. The laparoscopic Habib™ 4X sealer (Rita Medical Systems, Inc., Fremont, CA) is a promising device using bipolar radiofrequency energy. The purpose of the study was to test the safety and the efficiency of the device in laparoscopic left lateral sectionectomy. Five patients underwent laparoscopic left lateral sectionectomy using the laparoscopic Habib 4X in a period of 12 months. Indications for liver resection were hepatocellular carcinoma in 2 cirrhotic patients and colorectal cancer liver metastasis in 3 patients. Technical aspects were analyzed. All the patients underwent formal laparoscopic left lateral sectionectomy. The Pringle maneuver was not applied in any of the patients. Mean operative time was 75 minutes (range, 60-90 minutes). Bleeding control along the transection line was satisfactory. No conversion to laparotomy was required. Operative blood loss was minimal. No blood transfusion was recorded. The postoperative period was uneventful. Median hospital stay was 3 days (range, 2-5 days). Histopathology revealed that the margins were disease free. Laparoscopic left lateral segmentectomy with the use of Habib 4X proved safe and efficient. This technique may be an initial step for surgeons shifting to laparoscopic liver surgery provided they have previous experience in laparoscopic and liver surgery. Well-designed controlled randomized studies are needed in order to evaluate further the role of the device used in the present study in minimally invasive liver surgery.

  1. Lateral blasts at Mount St. Helens and hazard zonation

    Science.gov (United States)

    Crandell, D.R.; Hoblitt, R.P.

    1986-01-01

    Lateral blasts at andesitic and dacitic volcanoes can produce a variety of direct hazards, including ballistic projectiles which can be thrown to distances of at least 10 km and pyroclastic density flows which can travel at high speed to distances of more than 30 km. Indirect effect that may accompany such explosions include wind-borne ash, pyroclastic flows formed by the remobilization of rock debris thrown onto sloping ground, and lahars. Two lateral blasts occurred at a lava dome on the north flank of Mount St. Helens about 1200 years ago; the more energetic of these threw rock debris northeastward across a sector of about 30?? to a distance of at least 10 km. The ballistic debris fell onto an area estimated to be 50 km2, and wind-transported ash and lapilli derived from the lateral-blast cloud fell on an additional lobate area of at least 200 km2. In contrast, the vastly larger lateral blast of May 18, 1980, created a devastating pyroclastic density flow that covered a sector of as much as 180??, reached a maximum distance of 28 km, and within a few minutes directly affected an area of about 550 km2. The May 18 lateral blast resulted from the sudden, landslide-induced depressurization of a dacite cryptodome and the hydrothermal system that surrounded it within the volcano. We propose that lateral-blast hazard assessments for lava domes include an adjoining hazard zone with a radius of at least 10 km. Although a lateral blast can occur on any side of a dome, the sector directly affected by any one blast probably will be less than 180??. Nevertheless, a circular hazard zone centered on the dome is suggested because of the difficulty of predicting the direction of a lateral blast. For the purpose of long-term land-use planning, a hazard assessment for lateral blasts caused by explosions of magma bodies or pressurized hydrothermal systems within a symmetrical volcano could designate a circular potential hazard area with a radius of 35 km centered on the volcano

  2. A review of lateral driver support systems

    NARCIS (Netherlands)

    Tideman, Martijn; van der Voort, Mascha C.; van Arem, Bart; Tillema, Frans; Dailey, D.

    2007-01-01

    Lateral driver support systems have the potential to reduce the number of accidents associated with -both intentional and unintentional -lane departures. Additionally, such systems may increase driving comfort and stimulate a more efficient traffic flow, thereby reducing traffic emissions and the

  3. Electronic security device

    Science.gov (United States)

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  4. Electronic security device

    International Nuclear Information System (INIS)

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-01-01

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  5. Laterally Vibrating Resonator Based Elasto-Optic Modulation in Aluminum Nitride

    Science.gov (United States)

    2016-08-15

    the adjoining test setup used to probe the devices. Following the design of a laterally vibrating piezoelectric contour...licenses/by/4.0/). [http://dx.doi.org/10.1063/1.4945356] The interaction of acoustic waves with light provides a useful resource to perform optical signal...recent years, several types of acousto-optic interactions have been demonstrated in a wide va- riety of devices, including the use of

  6. Fragment capture device

    Science.gov (United States)

    Payne, Lloyd R.; Cole, David L.

    2010-03-30

    A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.

  7. Artificial lateral-line system for imaging dipole sources using Beamforming techniques

    NARCIS (Netherlands)

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    In nature, fish have the ability to localize prey, school, navigate, etc. using the lateral-line organ [1]. Here we present the use of biomimetic artificial hair-based flow-sensors arranged as lateral-line system in combination with beamforming techniques for dipole source localization in air.

  8. Flow pathways in the evolving critical zone - insights from hydraulic groundwater theory

    Science.gov (United States)

    Harman, C. J.; Cosans, C.; Kim, M.

    2017-12-01

    The geochemical signatures of the evolving critical zone are delivered into streams via saturated lateral flow through hillslopes. Here we will draw on hydraulic groundwater theory and scaling arguments to obtain insights into the first-order controls on the transition from vertical infiltration to lateral flow in the critical zone. Hydraulic groundwater theory aims to provide a simplified description of unconfined, saturated groundwater flow in systems that are substantially larger in lateral than vertical extent. The theory rests on the Dupuit assumptions, which are often erroneously stated as including an assumption of exclusively lateral flow. In fact the full three-dimensional flow field can be approximated from these assumptions. Building on this theory, we examine how overall hillslope structure (slope, permeability, convergence/divergence etc.) determines the direction and magnitude of flow in the vicinity of weathering fronts in the critical zone, and how weathering products are delivered to the hillslope base. The results demonstrate that under certain conditions the mere presence of lateral flow will not disturb the lateral symmetry of reaction fronts along the hillslope. Furthermore, coupling to a simple reaction model with porosity/permeability feedback allows us to examine the implications for weathering front advance where saturated lateral flow occurs as a transient perched aquifer at the weathering front. The overall rate of weathering front advance is found to be primarily determined by the component of flow normal to the weathering front, and only significantly accelerated by the lateral component above the weathering front when parent rock permeability is very low.

  9. Measurements of ion temperature and flow of pulsed plasmas produced by a magnetized coaxial plasma gun device using an ion Doppler spectrometer

    Science.gov (United States)

    Kitagawa, Y.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    It is important to know surface damage characteristics of plasma-facing component materials during transient heat and particle loads such as type I ELMs. A magnetized coaxial plasma gun (MCPG) device has been used as transient heat and particle source in ELM simulation experiments. Characteristics of pulsed plasmas produced by the MCPG device play an important role for the plasma material interaction. In this study, ion temperature and flow velocity of pulsed He plasmas were measured by an ion Doppler spectrometer (IDS). The IDS system consists of a light collection system including optical fibers, 1m-spectrometer and a 16 channel photomultiplier tube (PMT) detector. The IDS system measures the width and Doppler shift of HeII (468.58 nm) emission line with the time resolution of 1 μs. The Doppler broadened and shifted spectra were measured with 45 and 135 degree angles with respect to the plasmoid traveling direction. The observed emission line profile was represented by sum of two Gaussian components to determine the temperature and flow velocity. The minor component at around the wavelength of zero-velocity was produced by the stationary plasma. As the results, the ion velocity and temperature were 68 km/s and 19 eV, respectively. Thus, the He ion flow energy is 97 eV. The observed flow velocity agrees with that measured by a time of flight technique.

  10. Multipurpose sampler device for liquid metal

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Holmes, J.T.

    1975-01-01

    A device for collecting samples or examining a flow of liquid metal is provided for use with such as a liquid-metal-cooled nuclear reactor. The sampler device includes a casing surrounded by an external heater for establishing an upper isothermal zone and a lower zone for heating the entering liquid metal. One of various inserts is suspended into the isothermal zone where it is surrounded by a shroud tube for directing liquid-metal flow from the heating zone into the top of the insert. Discharge flow from the insert gravitates through a helically wound tube in heat exchange contact with entering liquid-metal flow within the heating zone. The inserts comprise an overflow cup with upper and lower freeze seals, a filter for removing particulate matter, and a fixture for maintaining various sample materials in equilibrium with liquid-metal flow. (U.S.)

  11. Device to measure elastic modulus of superconducting windings

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    This device was made to measure elastic modulus of the Po dipole superconducting coils. More elaborated devices, but based on the same concept, were later used to measure the apparent elastic moduli of the LHC superconducting magnet coils. See also 7903547X, 7901386.

  12. High energy devices versus low energy devices in orthopedics treatment modalities

    Science.gov (United States)

    Schultheiss, Reiner

    2003-10-01

    The orthopedic consensus group defined in 1997 the 42 most likely relevant parameters of orthopedic shock wave devices. The idea of this approach was to correlate the different clinical outcomes with the physical properties of the different devices with respect to their acoustical waves. Several changes in the hypothesis of the dose effect relationship have been noticed since the first orthopedic treatments. The relation started with the maximum pressure p+, followed by the total energy, the energy density; and finally the single treatment approach using high, and then the multiple treatment method using low energy. Motivated by the reimbursement situation in Germany some manufacturers began to redefine high and low energy devices independent of the treatment modality. The OssaTron as a high energy, single treatment electro hydraulic device gained FDA approval as the first orthopedic ESWT device for plantar fasciitis and, more recently, for lateral epicondylitis. Two low energy devices have now also gained FDA approval based upon a single treatment. Comparing the acoustic data, differences between the OssaTron and the other devices are obvious and will be elaborated upon. Cluster analysis of the outcomes and the acoustical data are presented and new concepts will be suggested.

  13. Return of neonatal CPAP resistance - the Medijet device family examined using in vitro flow simulations.

    Science.gov (United States)

    Falk, Markus; Donaldsson, Snorri; Jonsson, Baldvin; Drevhammar, Thomas

    2017-11-01

    Medijet nasal continuous positive airway pressure (CPAP) generators are a family of devices developed from the Benveniste valve. Previous studies have shown that the in vitro performance of the Medijet disposable generator was similar to the Neopuff resistor system. We hypothesised that resistance would be the main mechanism of CPAP generation in the Medijet disposable generator. The in vitro performance of the Medijet reusable and disposable systems, the Neopuff resistor system and the Benveniste and Infant Flow nonresistor systems were investigated using static and dynamic bench tests. Large differences in performance were found between the different systems. The disposable Medijet demonstrated high resistance, low pressure stability and high imposed work of breathing. The results also showed that encapsulating the Benveniste valve changed it into a resistor system. The main mechanism of CPAP generation for the disposable Medijet generator was resistance. The Medijet device family showed increasing resistance with each design generation. The high resistance of the Medijet disposable generator could be of great value when examining the clinical importance of pressure stability. Our results suggest that this device should be used cautiously in patients where pressure-stable CPAP is believed to be clinically important. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  14. 2-D simulation and analysis of temperature effects on electrical parameters degradation of power RF LDMOS device

    International Nuclear Information System (INIS)

    Belaid, M.A.; Ketata, K.; Gares, M.; Marcon, J.; Mourgues, K.; Masmoudi, M.

    2006-01-01

    This paper presents a synthesis of temperature effects on power RF Laterally Diffused (LD) MOS performances, which can modify and degrade transistor physical and electrical behaviour. In this work, the temperature influence on device electrical characteristics is discussed with regard to physical limits for device operation. A developed 2-D structure was implemented and simulated using the physical simulator Silvaco-Atlas to explain the observed data and offer insight into the physical origin of LDMOS temperature behaviour. The temperature dependence of most important electrical parameters such as channel current I ds , threshold voltage V th and inter-electrodes capacitances (C ds , C gs ) is investigated. The temperature effects on mobility, electron concentration, electric field, current flow lines and Fermi level are taken into account. Finally, initial failure analysis is discussed

  15. 2-D simulation and analysis of temperature effects on electrical parameters degradation of power RF LDMOS device

    Energy Technology Data Exchange (ETDEWEB)

    Belaid, M.A. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France)]. E-mail: Mohamed-ali.belaid@univ-rouen.fr; Ketata, K. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France); Gares, M. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France); Marcon, J. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France); Mourgues, K. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France); Masmoudi, M. [LEMI, University of Rouen, IUT Rouen, 76821 Mont Saint Aignan (France)

    2006-12-15

    This paper presents a synthesis of temperature effects on power RF Laterally Diffused (LD) MOS performances, which can modify and degrade transistor physical and electrical behaviour. In this work, the temperature influence on device electrical characteristics is discussed with regard to physical limits for device operation. A developed 2-D structure was implemented and simulated using the physical simulator Silvaco-Atlas to explain the observed data and offer insight into the physical origin of LDMOS temperature behaviour. The temperature dependence of most important electrical parameters such as channel current I {sub ds}, threshold voltage V {sub th} and inter-electrodes capacitances (C {sub ds}, C {sub gs}) is investigated. The temperature effects on mobility, electron concentration, electric field, current flow lines and Fermi level are taken into account. Finally, initial failure analysis is discussed.

  16. Quantum-Dot-Based Lateral Flow Immunoassay for Detection of Neonicotinoid Residues in Tea Leaves.

    Science.gov (United States)

    Wang, Shuangjie; Liu, Ying; Jiao, Shasha; Zhao, Ying; Guo, Yirong; Wang, Mengcen; Zhu, Guonian

    2017-11-22

    Neonicotinoid insecticides are commonly used for pest control on tea plantations as a result of their broad-spectrum activity. However, neonicotinoid residues released from tea leaves into tea infusions pose a dietary risk to consumers. Therefore, a rapid, sensitive, and reliable on-site detection method for neonicotinoids is needed. We developed a quantum-dot-based fluorescent lateral flow immunochromatographic strip (LFICS) combined with a broad-specific antibody for detection of typical neonicotinoids (imidacloprid, imidaclothiz, and clothianidin), with sensitivities [50% inhibitory concentration (IC 50 )] of 0.104-0.33 ng/mL and visual detection limits of 0.5-1 ng/mL. The strip assay could be completed in less than 30 min. Using the LFICS to analyze spiked tea samples (green tea, black tea, and oolong tea), the average recovery of the three neonicotinoids ranged between 71 and 111%, with the coefficient of variation below 12%. The results from the LFICS tests for field samples were consistent with results from ultraperformance liquid chromatography-tandem mass spectrometry. The newly developed strip is a useful tool for the on-site detection of neonicotinoid residues in tea.

  17. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  18. Boundary Layer Flows in Porous Media with Lateral Mass Flux

    DEFF Research Database (Denmark)

    Nemati, H; H, Bararnia; Noori, F

    2015-01-01

    Solutions for free convection boundary layers on a heated vertical plate with lateral mass flux embedded in a saturated porous medium are presented using the Homotopy Analysis Method and Shooting Numerical Method. Homotopy Analysis Method yields an analytic solution in the form of a rapidly...

  19. Application of particle image velocimetry measurement techniques to study turbulence characteristics of oscillatory flows around parallel-plate structures in thermoacoustic devices

    International Nuclear Information System (INIS)

    Mao, Xiaoan; Jaworski, Artur J

    2010-01-01

    This paper describes the development of the experimental setup and measurement methodologies to study the physics of oscillatory flows in the vicinity of parallel-plate stacks by using the particle image velocimetry (PIV) techniques. Parallel-plate configurations often appear as internal structures in thermoacoustic devices and are responsible for the hydrodynamic energy transfer processes. The flow around selected stack configurations is induced by a standing acoustic wave, whose amplitude can be varied. Depending on the direction of the flow within the acoustic cycle, relative to the stack, it can be treated as an entrance flow or a wake flow. The insight into the flow behaviour, its kinematics, dynamics and scales of turbulence, is obtained using the classical Reynolds decomposition to separate the instantaneous velocity fields into ensemble-averaged mean velocity fields and fluctuations in a set of predetermined phases within an oscillation cycle. The mean velocity field and the fluctuation intensity distributions are investigated over the acoustic oscillation cycle. The velocity fluctuation is further divided into large- and small-scale fluctuations by using fast Fourier transform (FFT) spatial filtering techniques

  20. Lateral shearing optical gradient force in coupled nanobeam photonic crystal cavities

    Energy Technology Data Exchange (ETDEWEB)

    Du, Han; Zhang, Xingwang; Chau, Fook Siong; Zhou, Guangya, E-mail: mpezgy@nus.edu.sg [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575 (Singapore); Deng, Jie [Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore 138634 (Singapore); Zhao, Yunshan [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583 (Singapore)

    2016-04-25

    We report the experimental observation of lateral shearing optical gradient forces in nanoelectromechanical systems (NEMS) controlled dual-coupled photonic crystal (PhC) nanobeam cavities. With an on-chip integrated NEMS actuator, the coupled cavities can be mechanically reconfigured in the lateral direction while maintaining a constant coupling gap. Shearing optical gradient forces are generated when the two cavity centers are laterally displaced. In our experiments, positive and negative lateral shearing optical forces of 0.42 nN and 0.29 nN are observed with different pumping modes. This study may broaden the potential applications of the optical gradient force in nanophotonic devices and benefit the future nanooptoelectromechanical systems.

  1. Apparatus for testing semiconductor devices and capacitors

    International Nuclear Information System (INIS)

    York, R.A.

    1984-01-01

    An apparatus is provided for testing semiconductor devices. The apparatus tests the impedance of the semiconductor devices in both conducting and non-conducting states to detect semiconductors whose impedance in the conducting state is too high or whose impedance in the non-conducting state is too low. The apparatus uses a battery source for low voltage d.c. The circuitry for detecting when the impedance is too high in the conducting state includes a lamp in series with the battery source and the semiconductor device, whereby the impedance of the semiconductor device determines whether sufficient current will flow through the lamp to cause the lamp to illuminate. A d.c. to d.c. converter is provided to boost the voltage from the battery source to a relatively high voltage d.c. The relatively high voltage d.c. can be connected by a switch to circuitry for detecting when the impedance of the semiconductor device in the non-conducting state is too low. The circuitry for detecting when the impedance of the semiconductor device is too low includes a resistor which senses the current flowing in the device and converts the current into a voltage proportional to the leakage current. This voltage is then compared against a fixed reference. Further circuitry is provided for providing a visual indication when the voltage representative of leakage in relation to the reference signal indicates that there is excessive current flow through the semiconductor device

  2. Flowing dusty plasma experiments: generation of flow and measurement techniques

    Science.gov (United States)

    Jaiswal, S.; Bandyopadhyay, P.; Sen, A.

    2016-12-01

    A variety of experimental techniques for the generation of subsonic/supersonic dust fluid flows and means of measuring such flow velocities are presented. The experiments have been carried out in a \\Pi -shaped dusty plasma experimental device with micron size kaolin/melamine formaldehyde particles embedded in a background of argon plasma created by a direct current glow discharge. A stationary dust cloud is formed over the cathode region by precisely balancing the pumping speed and gas flow rate. A flow of dust particles/fluid is generated by additional gas injection from a single or dual locations or by altering the dust confining potential. The flow velocity is then estimated by three different techniques, namely, by super particle identification code, particle image velocimetry analysis and the excitation of dust acoustic waves. The results obtained from these three different techniques along with their merits and demerits are discussed. An estimation of the neutral drag force responsible for the generation as well as the attenuation of the dust fluid flow is made. These techniques can be usefully employed in laboratory devices to investigate linear and non-linear collective excitations in a flowing dusty plasma.

  3. Quantum dots for future nanophotonic devices : lateral ordering, position, and number control

    NARCIS (Netherlands)

    Nötzel, R.; Sritirawisarn, N.; Selçuk, E.; Wang, H.; Yuan, J.

    2009-01-01

    We review our recent advances in the lateral ordering, position, and number control of self-organized epitaxial semiconductor quantum dots based on self-organized anisotropic strain engineering, growth on patterned substrates, and selective area growth.

  4. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan.

    Science.gov (United States)

    Mizanbayeva, Sulushash; Smits, Henk L; Zhalilova, Katya; Abdoel, Theresia H; Kozakov, Stanislaw; Ospanov, Kenes S; Elzer, Philip H; Douglas, James T

    2009-09-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high sensitivity of these assays. The strong reactivity in the LFA observed for the majority (92.1%) of the samples from the patients with culture-confirmed brucellosis together with the user-friendliness of the assay procedure makes the LFA ideal for the confirmation of brucellosis in endemic areas in Kazakhstan. The Rose Bengal test lacked sensitivity in particular for patients with chronic brucellosis therefore limiting its value as a quick screening assay. The study emphasizes the importance of the LFA as a useful, rapid, and easy-to-perform tool in the diagnostic testing of brucellosis.

  5. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1968-01-01

    Electronic Devices and Circuits, Volume 1 deals with the design and applications of electronic devices and circuits such as passive components, diodes, triodes and transistors, rectification and power supplies, amplifying circuits, electronic instruments, and oscillators. These topics are supported with introductory network theory and physics. This volume is comprised of nine chapters and begins by explaining the operation of resistive, inductive, and capacitive elements in direct and alternating current circuits. The theory for some of the expressions quoted in later chapters is presented. Th

  6. A novel multi-level IC-compatible surface microfabrication technology for MEMS with independently controlled lateral and vertical submicron transduction gaps

    Science.gov (United States)

    Cicek, Paul-Vahe; Elsayed, Mohannad; Nabki, Frederic; El-Gamal, Mourad

    2017-11-01

    An above-IC compatible multi-level MEMS surface microfabrication technology based on a silicon carbide structural layer is presented. The fabrication process flow provides optimal electrostatic transduction by allowing the creation of independently controlled submicron vertical and lateral gaps without the need for high resolution lithography. Adopting silicon carbide as the structural material, the technology ensures material, chemical and thermal compatibility with modern semiconductor nodes, reporting the lowest peak processing temperature (i.e. 200 °C) of all comparable works. This makes this process ideally suited for integrating capacitive-based MEMS directly above standard CMOS substrates. Process flow design and optimization are presented in the context of bulk-mode disk resonators, devices that are shown to exhibit improved performance with respect to previous generation flexural beam resonators, and that represent relatively complex MEMS structures. The impact of impending improvements to the fabrication technology is discussed.

  7. A novel multi-level IC-compatible surface microfabrication technology for MEMS with independently controlled lateral and vertical submicron transduction gaps

    International Nuclear Information System (INIS)

    Cicek, Paul-Vahe; Elsayed, Mohannad; Nabki, Frederic; El-Gamal, Mourad

    2017-01-01

    An above-IC compatible multi-level MEMS surface microfabrication technology based on a silicon carbide structural layer is presented. The fabrication process flow provides optimal electrostatic transduction by allowing the creation of independently controlled submicron vertical and lateral gaps without the need for high resolution lithography. Adopting silicon carbide as the structural material, the technology ensures material, chemical and thermal compatibility with modern semiconductor nodes, reporting the lowest peak processing temperature (i.e. 200 °C) of all comparable works. This makes this process ideally suited for integrating capacitive-based MEMS directly above standard CMOS substrates. Process flow design and optimization are presented in the context of bulk-mode disk resonators, devices that are shown to exhibit improved performance with respect to previous generation flexural beam resonators, and that represent relatively complex MEMS structures. The impact of impending improvements to the fabrication technology is discussed. (paper)

  8. Ecosystem processes at the watershed scale: hydrologic vegetation gradient as an indicator for lateral hydrologic connectivity of headwater catchments

    Science.gov (United States)

    Taehee Hwang; James M. Vose; Christina. Tague

    2012-01-01

    Lateral water flow in catchments can produce important patterns in water and nutrient fluxes and stores and also influences the long-term spatial development of forest ecosystems. Specifically, patterns of vegetation type and density along hydrologic flow paths can represent a signal of the redistribution of water and nitrogen mediated by lateral hydrologic flow. This...

  9. Studies of switching structures in ferroelectric liquid crystal devices

    International Nuclear Information System (INIS)

    Pabla, D.S.

    1998-01-01

    The fast, bistable electro-optic response of ferroelectric liquid crystal (FLC) devices has made them prime candidates for use in display applications. However, before these applications can become widely commercially viable a number of key issues relating to the switching within these devices need to be addressed. One of these is related to the fact that while there has been much work done on modelling the switching process in FLC devices, with some moderate success, in the main these models have not accurately accounted for the physical processes taking place. In order to rectify this situation we present a simple, multi-variable approach which includes important physical phenomenon such as stressed states, partial and domain switching. Through using this model we learn more about the dynamic molecular profiles which may exist in devices, and use this as a springboard to undertake a comprehensive theoretical and experimental study of the molecular profiles of chevron structures under different types of addressing pulses and voltages. This entails modelling the dynamic profiles using a simple non flow reorientation theory and comparing these simulations directly with experimental data obtained through the use of two different optical characterisation techniques. Our findings show quite conclusively that for monopolar addressing within low and high voltage regimes and for low voltage bipolar pulses during the early stages of switching, the dynamic reorientation near the surfaces and central regions of the device lags the reorientation within the bulk. The reverse however being true for the high voltage bipolar addressing case. These results for chevron structures differ from previous theoretical predictions made by others using equations derived from the flow coupled chiral smectic C continuum theory. These flow coupled simulations however, refer to reorientation in bookshelf structures rather than the chevron type structures thought to exist in FLC devices. As

  10. Studies of switching structures in ferroelectric liquid crystal devices

    Energy Technology Data Exchange (ETDEWEB)

    Pabla, D.S

    1998-07-01

    The fast, bistable electro-optic response of ferroelectric liquid crystal (FLC) devices has made them prime candidates for use in display applications. However, before these applications can become widely commercially viable a number of key issues relating to the switching within these devices need to be addressed. One of these is related to the fact that while there has been much work done on modelling the switching process in FLC devices, with some moderate success, in the main these models have not accurately accounted for the physical processes taking place. In order to rectify this situation we present a simple, multi-variable approach which includes important physical phenomenon such as stressed states, partial and domain switching. Through using this model we learn more about the dynamic molecular profiles which may exist in devices, and use this as a springboard to undertake a comprehensive theoretical and experimental study of the molecular profiles of chevron structures under different types of addressing pulses and voltages. This entails modelling the dynamic profiles using a simple non flow reorientation theory and comparing these simulations directly with experimental data obtained through the use of two different optical characterisation techniques. Our findings show quite conclusively that for monopolar addressing within low and high voltage regimes and for low voltage bipolar pulses during the early stages of switching, the dynamic reorientation near the surfaces and central regions of the device lags the reorientation within the bulk. The reverse however being true for the high voltage bipolar addressing case. These results for chevron structures differ from previous theoretical predictions made by others using equations derived from the flow coupled chiral smectic C continuum theory. These flow coupled simulations however, refer to reorientation in bookshelf structures rather than the chevron type structures thought to exist in FLC devices. As

  11. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  12. Design lateral heterostructure of monolayer ZrS2 and HfS2 from first principles calculations

    Science.gov (United States)

    Yuan, Junhui; Yu, Niannian; Wang, Jiafu; Xue, Kan-Hao; Miao, Xiangshui

    2018-04-01

    The successful fabrication of two-dimensional lateral heterostructures (LHS's) has opened up unprecedented opportunities in material science and device physics. It is therefore highly desirable to search for more suitable materials to create such heterostructures for next-generation devices. Here, we investigate a novel lateral heterostructure composed of monolayer ZrS2 and HfS2 based on density functional theory. The phonon dispersion and ab initio molecular dynamics analysis indicate its good kinetic and thermodynamic stability. Remarkably, we find that these lateral heterostructures exhibit an indirect to direct bandgap transition, in contrast to the intrinsic indirect bandgap nature of ZrS2 and HfS2. The type-II alignment and chemical bonding across the interline have also been revealed. The tensile strain is proved to be an efficient way to modulate the band structure. Finally, we further discuss other three stable lateral heterostructures: (ZrSe2)2(HfSe2)2 LHS, (ZrS2)2(ZrSe2)2 LHS and (HfS2)2(HfSe2)2 LHS. Generally, the lateral heterostructures of monolayer ZrS2 and HfS2 are of excellent electrical properties, and may find potential applications for future electronic devices.

  13. Electrochemistry in hollow-channel paper analytical devices.

    Science.gov (United States)

    Renault, Christophe; Anderson, Morgan J; Crooks, Richard M

    2014-03-26

    In the present article we provide a detailed analysis of fundamental electrochemical processes in a new class of paper-based analytical devices (PADs) having hollow channels (HCs). Voltammetry and amperometry were applied under flow and no flow conditions yielding reproducible electrochemical signals that can be described by classical electrochemical theory as well as finite-element simulations. The results shown here provide new and quantitative insights into the flow within HC-PADs. The interesting new result is that despite their remarkable simplicity these HC-PADs exhibit electrochemical and hydrodynamic behavior similar to that of traditional microelectrochemical devices.

  14. Numerical determination of lateral loss coefficients for subchannel analysis in nuclear fuel bundles

    Energy Technology Data Exchange (ETDEWEB)

    Sin Kim; Goon-Cherl Park [Seoul National Univ., Seoul (Korea, Republic of)

    1995-09-01

    An accurate prediction of cross-flow based on detailed knowledge of the velocity field in subchannels of a nuclear fuel assembly is of importance in nuclear fuel performance analysis. In this study, the low-Reynolds number {kappa}-{epsilon} turbulence model has been adopted in two adjacent subchannels with cross-flow. The secondary flow is estimated accurately by the anisotropic algebraic Reynolds stress model. This model was numerically calculated by the finite element method and has been verified successfully through comparison with existing experimental data. Finally, with the numerical analysis of the velocity field in such subchannel domain, an analytical correlation of the lateral loss coefficient is obtained to predict the cross-flow rate in subchannel analysis codes. The correlation is expressed as a function of the ratio of the lateral flow velocity to the donor subchannel axial velocity, recipient channel Reynolds number and pitch-to-diameter.

  15. Polarity Control and Growth of Lateral Polarity Structures in AlN

    Science.gov (United States)

    2013-05-10

    devices similar to those predicted for GaN.5 This could include high-power and high-frequency field effect transistors, efficient ultraviolet ( UV ) light...emitting diodes, or UV -laser light generation via frequency doubling.6 A few prerequisites are lateral control on the micrometer or even nanometer...the limited lateral resolution of micro Raman spectros - copy, no spectra could be obtained from the inversion domain boundary.9 Spectra were recorded

  16. Evaluation of a lateral flow-based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions.

    Science.gov (United States)

    Clavier, Benoît; Pouget, Thomas; Sailliol, Anne

    2018-02-01

    Life-threatening situations requiring blood transfusion under extreme conditions or in remote and austere locations, such as the battlefield or in traffic accidents, would benefit from reliable blood typing practices that are easily understood by a nonscientist or nonlaboratory technician and provide quick results. A simplified protocol was developed for the lateral flow-based device MDmulticard ABO-D-Rh subgroups-K. Its performance was compared to a reference method (PK7300, Beckman Coulter) in native blood samples from donors. The method was tested on blood samples stressed in vitro as a model of hemorrhage cases (through hemodilution using physiologic serum) and dehydration (through hemoconcentration by removing an aliquot of plasma after centrifugation), respectively. A total of 146 tests were performed on 52 samples; 126 in the hemodilution group (42 for each native, diluted 1/2, and diluted 1/4 samples) and 20 in the hemoconcentration group (10 for each native and 10% concentrated samples). Hematocrit in the tested samples ranged from 9.8% to 57.6% while hemoglobin levels ranged from 3.2 to 20.1 g/dL. The phenotype profile detected with the MDmulticard using the simplified protocol resulted in 22 A, seven B, 20 O, and three AB, of which nine were D- and five were Kell positive. No discrepancies were found with respect to the results obtained with the reference method. The simplified protocol for MDmulticard use could be considered a reliable method for blood typing in extreme environment or emergency situations, worsened by red blood cell dilution or concentration. © 2017 AABB.

  17. Failed fuel detection device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1994-01-01

    The device of the present invention concerns a failed fuel detection device for a nuclear reactor, such as an FBR type reactor, using electroconductive coolants. A sampling port is disposed at the upper portion of the fuel assembly so as to cover the assembly, so that coolants in the fuel assembly are sampled to improve a device for detecting fuel failure. That is, when coolants in the fuel assembly are sampled from the sampling port, the flow of electroconductive coolants in an sampling tube is detected by a flowmeter, to control an electromagnetic pump. The flow of electroconductive coolants is stopped against the waterhead pressure and dynamic pressure of the conductive coolants, and a predetermined amount of the coolants is pumped up to the sampling tank. Gas is supplied to the pumped up coolants so that fissile products are transferred from the coolants to a gas phase. Radiation in the gas in a gas recycling system is measured to detect presence of fuel failure. (I.S.)

  18. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  19. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  20. Using a Microfluidic-Microelectric Device to Directly Separate Serum/Blood Cells from a Continuous Whole Bloodstream Flow

    Science.gov (United States)

    Wang, Ming-Wen; Jeng, Kuo-Shyang; Yu, Ming-Che; Su, Jui-Chih

    2012-03-01

    To make the rapid separation of serum/blood cells possible in a whole bloodstream flow without centrifugation and Pasteur pipette suction, the first step is to use a microchannel to transport the whole bloodstream into a microdevice. Subsequently, the resulting serum/blood cell is separated from the whole bloodstream by applying other technologies. Creating the serum makes this subsequent separation possible. To perform the actual separation, a microchannel with multiple symmetric curvilinear microelectrodes has been designed on a glass substrate and fabricated with micro-electromechanical system technology. The blood cells can be observed clearly by black-field microscopy imaging. A local dielectrophoretic (DEP) force, obtained from nonuniform electric fields, was used for manipulating and separating the blood cells from a continuous whole bloodstream. The experimental studies show that the blood cells incur a local dielectrophoretic field when they are suspended in a continuous flow (v = 0.02-0.1 cm/s) and exposed to AC fields at a frequency of 200 kHz. Using this device, the symmetric curvilinear microelectrodes provide a local dielectrophoretic field that is sufficiently strong for separating nearby blood cells and purifying the serum in a continuous whole bloodstream flow.

  1. [Evaluation and Optimization of Microvascular Arterial Anastomoses by Transit Time Flow Measurement].

    Science.gov (United States)

    Herberhold, S; Röttker, J; Bartmann, D; Solbach, A; Keiner, S; Welz, A; Bootz, F; Laffers, W

    2016-03-01

    INDRODUCTION: The regular application of transit time flow measurement in microvascular anastomoses during heart surgery has lead to improvements of the outcome of coronary artery bypass grafts. Our study was meant to discover whether this measurement method was also applicable for evaluation and optimization of microvascular arterial anastomoses of radial forearm flaps. In this prospective examination a combining ultrasound imaging and transit time flow measurement device (VeriQ, MediStim) was used during surgery to assess anastomotic quality of 15 radial forearm flaps. Pulsatility index (PI) and mean blood flow were measured immediately after opening the arterial anastomosis as well as 15 min afterwards. Furthermore, application time and description of handling were recorded seperately for every assessment. Mean blood flow immediately after opening the anastomosis and 15 min later were 3.9 and 3.4 ml/min resepectively showing no statistically significant difference (p=0.96). There was no significance in the increase of pulsatility index from 22.1 to 27.2 (p=0.09) during the same time range, either. Due to measurement results showing atypical pulse curves in 2 cases decision for surgical revision of the anastomoses was made. All forearm flaps showed good vascularisation during follow-up. Time for device set up, probe placement and measurements was about 20 min. Handling was described to be uncomplicated without exception. There were no noteworthy problems. Transit time flow measurement contributes to the improvement of anastomotic quality and therefore to the overall outcome of radial forearm flaps. The examined measurement method provides objective results and is useful for documentation purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Hydrocephalus secondary to obstruction of the lateral apertures in two dogs.

    Science.gov (United States)

    Kent, M; Glass, E N; Haley, A C; Shaikh, L S; Sequel, M; Blas-Machado, U; Bishop, T M; Holmes, S P; Platt, S R

    2016-11-01

    Traditionally, hydrocephalus is divided into communicating or non-communicating (obstructive) based on the identification of a blockage of cerebrospinal fluid (CSF) flow through the ventricular system. Hydrocephalus ex vacuo refers to ventricular enlargement as a consequence of neuroparenchymal loss. Hydrocephalus related to obstruction of the lateral apertures of the fourth ventricles has rarely been described. The clinicopathologic findings in two dogs with hydrocephalus secondary to obstruction of the lateral apertures of the fourth ventricle are reported. Signs were associated with a caudal cervical spinal cord lesion in one dog and a caudal brain stem lesion in the other dog. Magnetic resonance imaging (MRI) disclosed dilation of the ventricular system, including the lateral recesses of the fourth ventricle. In one dog, postmortem ventriculography confirmed obstruction of the lateral apertures. Microscopic changes were identified in the choroid plexus in both dogs, yet a definitive cause of the obstructions was not identified. The MRI findings in both dogs are similar to membranous occlusion of the lateral and median apertures in human patients. MRI detection of dilation of the entire ventricular system in the absence of an identifiable cause should prompt consideration of an obstruction of the lateral apertures. In future cases, therapeutic interventions aimed at re-establishing CSF flow or ventriculoperitoneal catheterisation should be considered. © 2016 Australian Veterinary Association.

  3. Reactor feedwater control device

    International Nuclear Information System (INIS)

    Koshi, Yuji.

    1993-01-01

    In the device of the present invention, an excess response is not caused in a reactor feed water system even when voids are fluctuated by using an actual water level signal as a reactor water level signal. That is, a standard water level signal and a reactor water level signal are inputted to a comparator. An adder adds water level difference signal outputted from the comparator and mismatch flow rate signal prepared by multiplying the difference between a main steam flow rate signal and a feed water flow rate signal by a mismatch gain. A feed water controller integrates the added signal and outputs flow rate demand signal. A feed water system receives the flow rate demand signal as input. A water level calculation means is disposed to such a device for calculating an actual water level based on the change of coolant possessing amount of the reactor, and the output thereof is defined as a reactor water level signal. With such procedures, excessive elevation of water level of the reactor can be prevented even upon occurrence of void fluctuation phenomenon or the like in the reactor such as upon sole scram operation. Accordingly, plant shut down caused thereby can be avoided safely. (I.S.)

  4. Mineral extraction and transport device

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, K.

    1991-08-21

    A device for the extraction and transport of stratified mineral deposits notably coal, having a transport run with lengths of transport troughing, an extraction run with lengths of extraction troughing, and a power-driven traction chain guided round return devices and carrying extraction bodies together with optional transport units. The transport and extraction troughing have guide members on which the extraction bodies and the transport units are guided with the aid of guide formations. Each extraction body consists of a headpiece having two laterally protruding guide formations, and an endpiece having two laterally protruding guide formations and a centrepiece. The headpiece and the endpiece are swivellably linked to the centrepiece through an axis running substantially at right angles to the traction axis of the traction chain and substantially at right angles to the floor of the lengths of transport troughing in the transport run. The centrepiece has an additional articulation about an axis substantially orthogonal to the swivel axis of the headpiece and the endpiece. Guide members are additionally provided in the vicinity of the return devices whereby the guide formations on each headpiece and endpiece receive continued guidance.

  5. Giant magnetoresistance in lateral metallic nanostructures for spintronic applications.

    Science.gov (United States)

    Zahnd, G; Vila, L; Pham, V T; Marty, A; Beigné, C; Vergnaud, C; Attané, J P

    2017-08-25

    In this letter, we discuss the shift observed in spintronics from the current-perpendicular-to-plane geometry towards lateral geometries, illustrating the new opportunities offered by this configuration. Using CoFe-based all-metallic LSVs, we show that giant magnetoresistance variations of more than 10% can be obtained, competitive with the current-perpendicular-to-plane giant magnetoresistance. We then focus on the interest of being able to tailor freely the geometries. On the one hand, by tailoring the non-magnetic parts, we show that it is possible to enhance the spin signal of giant magnetoresistance structures. On the other hand, we show that tailoring the geometry of lateral structures allows creating a multilevel memory with high spin signals, by controlling the coercivity and shape anisotropy of the magnetic parts. Furthermore, we study a new device in which the magnetization direction of a nanodisk can be detected. We thus show that the ability to control the magnetic properties can be used to take advantage of all the spin degrees of freedom, which are usually occulted in current-perpendicular-to-plane devices. This flexibility of lateral structures relatively to current-perpendicular-to-plane structures is thus found to offer a new playground for the development of spintronic applications.

  6. Distributed amplifier using Josephson vortex flow transistors

    International Nuclear Information System (INIS)

    McGinnis, D.P.; Beyer, J.B.; Nordman, J.E.

    1986-01-01

    A wide-band traveling wave amplifier using vortex flow transistors is proposed. A vortex flow transistor is a long Josephson junction used as a current controlled voltage source. The dual nature of this device to the field effect transistor is exploited. A circuit model of this device is proposed and a distributed amplifier utilizing 50 vortex flow transistors is predicted to have useful gain to 100 GHz

  7. The Influence of Positioning of the Nellix Endovascular Aneurysm Sealing System on Suprarenal and Renal Flow: An In Vitro Study.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Van de Velde, Lennart; Versluis, Michel; Lajoinie, Guillaume; Slump, Cornelius H; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-10-01

    To examine the influence of device positioning and infrarenal neck diameter on flow patterns in the Nellix endovascular aneurysm sealing (EVAS) system. The transition of the aortic flow lumen into two 10-mm-diameter stents after EVAS creates a mismatched area. Flow recirculation may affect local wall shear stress (WSS) profiles and residence time associated with atherosclerosis and thrombosis. To examine these issues, 7 abdominal aortic aneurysm flow phantoms were created, including 3 unstented controls and 3 stented models with infrarenal neck diameters of 24, 28, and 32 mm. Stents were positioned within the instructions for use (IFU). Another 28-mm model was created to evaluate lower positioning of the stents outside the IFU (28-mm LP). Flow was visualized using optical particle imaging velocimetry (PIV) and quantified by time-averaged WSS (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) in the aorta at the anteroposterior (AP) midplane, lateral midplane, and renal artery AP midplane levels. Flow in the aorta AP midplane was similar in all models. Vortices were observed in the stented models in the lateral midplane near the anterior and posterior walls. In the 32-mm IFU and 28-mm LP models, a steady state of vortices appeared, with varying location during a cycle. In all models, a low TAWSS (OSI of 0.5 and peak RRT of 10 4 Pa -1 . This region was more proximally located in the stented models. The 24- and 28-mm IFU models showed flow with a higher velocity at the renal artery inflow compared to controls. TAWSS in the renal artery was lower near the orifice in all models, with the largest area in the 24-mm IFU model. OSI and RRT in the renal artery were near zero for all models. EVAS enhances vorticity proximal to the seal zone, especially with lower positioning of the device and in larger neck diameters. Endobags just below the renal artery affect the flow profile in a minor area of this artery in 24- and 28-mm necks, while lower stent

  8. Development of fluidic device in SIT for Korean Next Generation Reactor I

    International Nuclear Information System (INIS)

    Cho, Bong Hyun; Lee, Joon; Bae, Yoon Young; Park, Jong Kyun

    1999-07-01

    The KNGR is to install a Fluidic Device at the bottom of the inner space of the SIT (Safety Injection Tank) to control the flow rate of safety injection coolant from SIT during LBLOCA. During the past two years, a scale model test to obtain the required flow characteristics of the device under the KNGR specific conditions has been performed using the experience and existing facility of AEA Technology (UK) with appropriate modifications. The performance verification test is to be performed this year to obtain optimum characteristics and design data of full size fluidic device. The purpose of the model test was to check the feasibility of developing the device and to produce a generic flow characteristic data. The test was performed in approximately 1/7 scale in terms of flow rate with full height and pressure. This report presents the details of system performance requirements for the device, design procedure for the fluidic device to be used, test facility and test method. The time dependent flow, pressure and Euler number are presented as characteristics curves and the most stable and the most effective flow control characteristic parameters were recommended through the evaluation. A method to predict the size of the fluidic device is presented. And a sizing algorithm, which can be used to conveniently determine the major geometric data of the device for various operating conditions, and a FORTRAN program to produce the prediction of performance curves have been developed. (author). 32 refs., 15 tabs., 47 figs

  9. 78 FR 35173 - Physical Medicine Devices; Reclassification of Stair-Climbing Wheelchairs

    Science.gov (United States)

    2013-06-12

    ... necessary to assure the safety and effectiveness of the device. II. Regulatory History of the Device On... petitioner's own history of use, the petitioner's own preclinical testing, and the development of relevant... inclined planes (forward, backward, and lateral); [cir] Demonstration of the ability of the device to...

  10. Oahu Sewer Lateral Lines, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Inventory of sewer laterals, used for tracking, monitoring, and flow analysis as maintained by Honolulu ENV Department of Environmental Services. The base sewer...

  11. Orthotic devices for tennis elbow

    NARCIS (Netherlands)

    Struijs, P. A.; Smidt, N.; Arola, H.; van Dijk, C. N.; Buchbinder, R.; Assendelft, W. J.

    2001-01-01

    BACKGROUND: Lateral epicondylitis (tennis elbow) is a frequently reported condition. A wide variety of treatment strategies has been described. As of yet, no optimal strategy has been identified. OBJECTIVES: The objective of this review was to assess the effectiveness of orthotic devices for

  12. Development and evaluation of a new lateral flow immunoassay for serodiagnosis of human fasciolosis.

    Directory of Open Access Journals (Sweden)

    Victoria Martínez-Sernández

    2011-11-01

    Full Text Available BACKGROUND: Human fasciolosis is a re-emerging disease worldwide and is caused by species of the genus Fasciola (F. hepatica and F. gigantica. Human fasciolosis can be diagnosed by classical coprological techniques, such as the Kato-Katz test, to reveal parasite eggs in faeces. However, although 100% specific, these methods are generally not adequate for detection of acute infections, ectopic infections, or infections with low number of parasites. In such cases immunological methods may be a good alternative and are recommended for use in major hospitals where trained personnel are available, although they are not usually implemented for individual testing. METHODOLOGY/PRINCIPAL FINDINGS: We have developed a new lateral flow test (SeroFluke for the serodiagnosis of human fasciolosis. The new test was constructed with a recombinant cathepsin L1 from F. hepatica, and uses protein A and mAb MM3 as detector reagents in the test and control lines, respectively. In comparison with an ELISA test (MM3-SERO the SeroFluke test showed maximal specificity and sensitivity and can be used with serum or whole blood samples. CONCLUSIONS/SIGNIFICANCE: The new test can be used in major hospitals in hypoendemic countries as well as in endemic/hyperendemic regions where point-of-care testing is required.

  13. Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein

    Science.gov (United States)

    Qi, XiaoPing; Huang, YunYe; Lin, ZhongShi; Xu, Liang; Yu, Hao

    2016-03-01

    In the article, a dual-quantum-dots-labeled (dual-QDs-labeled) lateral flow strip (LFS) method was developed for the simultaneous and rapid quantitative detection of procalcitonin (PCT) and C-reactive protein (CRP) in the blood. Two QD-antibody conjugates with different fluorescence emission spectra were produced and sprayed on the LFS to capture PCT and CRP in the blood. Furthermore, a double antibody sandwich method for PCT and, meanwhile, a competitive inhibition method for CRP were employed in the LFS. For PCT and CRP in serum assayed by the dual-QDs-labeled LFS, their detection sensitivities reached 0.1 and 1 ng/mL, respectively, and their linear quantitative detection ranges were from 0.3 to 200 ng/mL and from 50 to 250 μg/mL, respectively. There was little evidence that the PCT and CRP assays would be interfered with each other. The correlations for testing CRP and PCT in clinical samples were 99.75 and 97.02 %, respectively, between the dual-QDs-labeled LFS we developed and commercial methods. The rapid quantification of PCT and CRP on dual-QDs-labeled LFS is of great clinical value to distinguish inflammation, bacterial infection, or viral infection and to provide guidance for the use of antibiotics or other medicines.

  14. A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples

    Directory of Open Access Journals (Sweden)

    Guilan Zhang

    2018-01-01

    Full Text Available Ochratoxin A (OTA is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluorescent aptasensor for one-step determination of OTA in corn samples. Briefly, biotin-cDNA was immobilized on the surface of a nitrocellulose filter on the test line. Without OTA, Cy5-labeled aptamer combined with complementary strands formed a stable double helix. In the presence of OTA, however, the Cy5-aptamer/OTA complexes were generated, and therefore less free aptamer was captured in the test zone, leading to an obvious decrease in fluorescent signals on the test line. The test strip showed an excellent linear relationship in the range from 1 ng·mL−1 to 1000 ng·mL−1 with the LOD of 0.40 ng·mL−1, IC15 value of 3.46 ng·mL−1 and recoveries from 96.4% to 104.67% in spiked corn samples. Thus, the strip sensor developed in this study is an acceptable alternative for rapid detection of the OTA level in grain samples.

  15. Device of capturing for radioactive corrosion products

    International Nuclear Information System (INIS)

    Ohara, Atsushi; Fukushima, Kimichika.

    1984-01-01

    Purpose: To increase the area of contact between the capturing materials for the radioactive corrosion products contained in the coolants and the coolants by producing stirred turbulent flows in the coolant flow channel of LMFBR type reactors. Constitution: Constituent materials for the nuclear fuel elements or the reactor core structures are activated under the neutron irradiation, corroded and transferred into the coolants. While capturing devices made of pure metal nickel are used for the elimination of the corrosion products, since the coolants form laminar flows due to the viscosity thereof near the surface of the capturing materials, the probability that the corrosion products in the coolants flowing through the middle portion of the channel contact the capturing materials is reduced. In this invention, rotating rolls and flow channels in which the balls are rotated are disposed at the upstream of the capturing device to forcively disturb the flow of the liquid sodium, whereby the radioactive corrosion products can effectively be captured. (Kamimura, M.)

  16. Biomedical device prototype based on small scale hydrodynamic cavitation

    Science.gov (United States)

    Ghorbani, Morteza; Sozer, Canberk; Alcan, Gokhan; Unel, Mustafa; Ekici, Sinan; Uvet, Huseyin; Koşar, Ali

    2018-03-01

    This study presents a biomedical device prototype based on small scale hydrodynamic cavitation. The application of small scale hydrodynamic cavitation and its integration to a biomedical device prototype is offered as an important alternative to other techniques, such as ultrasound therapy, and thus constitutes a local, cheap, and energy-efficient solution, for urinary stone therapy and abnormal tissue ablation (e.g., benign prostate hyperplasia (BPH)). The destructive nature of bubbly, cavitating, flows was exploited, and the potential of the prototype was assessed and characterized. Bubbles generated in a small flow restrictive element (micro-orifice) based on hydrodynamic cavitation were utilized for this purpose. The small bubbly, cavitating, flow generator (micro-orifice) was fitted to a small flexible probe, which was actuated with a micromanipulator using fine control. This probe also houses an imaging device for visualization so that the emerging cavitating flow could be locally targeted to the desired spot. In this study, the feasibility of this alternative treatment method and its integration to a device prototype were successfully accomplished.

  17. Biomedical device prototype based on small scale hydrodynamic cavitation

    Directory of Open Access Journals (Sweden)

    Morteza Ghorbani

    2018-03-01

    Full Text Available This study presents a biomedical device prototype based on small scale hydrodynamic cavitation. The application of small scale hydrodynamic cavitation and its integration to a biomedical device prototype is offered as an important alternative to other techniques, such as ultrasound therapy, and thus constitutes a local, cheap, and energy-efficient solution, for urinary stone therapy and abnormal tissue ablation (e.g., benign prostate hyperplasia (BPH. The destructive nature of bubbly, cavitating, flows was exploited, and the potential of the prototype was assessed and characterized. Bubbles generated in a small flow restrictive element (micro-orifice based on hydrodynamic cavitation were utilized for this purpose. The small bubbly, cavitating, flow generator (micro-orifice was fitted to a small flexible probe, which was actuated with a micromanipulator using fine control. This probe also houses an imaging device for visualization so that the emerging cavitating flow could be locally targeted to the desired spot. In this study, the feasibility of this alternative treatment method and its integration to a device prototype were successfully accomplished.

  18. Design and analysis of compact ultra energy-efficient logic gates using laterally-actuated double-electrode NEMS

    KAUST Repository

    Dadgour, Hamed F.; Hussain, Muhammad Mustafa; Smith, Casey Eben; Banerjee, Kaustav

    2010-01-01

    Nano-Electro-Mechanical Switches (NEMS) are among the most promising emerging devices due to their near-zero subthreshold-leakage currents. This paper reports device fabrication and modeling, as well as novel logic gate design using "laterally

  19. A respiratory monitoring device based on clavicular motion

    International Nuclear Information System (INIS)

    Pitts, D G; Aspinall, R; Patel, M K; Lang, P-O; Sinclair, A J

    2013-01-01

    Respiratory rate is one of the key vital signs yet unlike temperature, heart rate or blood pressure, there is no simple and low cost measurement device for medical use. Here we discuss the development of a respiratory sensor based upon clavicular motion and the findings of a pilot study comparing respiratory rate readings derived from clavicular and thoracic motion with an expiratory breath flow reference sensor. Simultaneously sampled data from resting volunteers (n = 8) was analysed to determine the location of individual breaths in the data set and from these, breath periods and frequency were calculated. Clavicular sensor waveforms were found to be more consistent and of greater amplitude than those from the thoracic device, demonstrating good alignment with the reference waveform. On comparing breath by breath periods a close agreement was observed with the reference, with mean clavicular respiratory rate R 2 values of 0.89 (lateral) and 0.98 (longitudinal-axis). This pilot study demonstrates the viability of clavicular respiratory sensing. The sensor is unobtrusive, unaffected by bioelectrical or electrode problems and easier to determine and more consistent than thoracic motion sensing. With relatively basic signal conditioning and processing requirements, it could provide an ideal platform for a low-cost respiratory monitor. (note)

  20. MOSFET-BJT hybrid mode of the gated lateral bipolar junction transistor for C-reactive protein detection.

    Science.gov (United States)

    Yuan, Heng; Kwon, Hyurk-Choon; Yeom, Se-Hyuk; Kwon, Dae-Hyuk; Kang, Shin-Won

    2011-10-15

    In this study, we propose a novel biosensor based on a gated lateral bipolar junction transistor (BJT) for biomaterial detection. The gated lateral BJT can function as both a BJT and a metal-oxide-semiconductor field-effect transistor (MOSFET) with both the emitter and source, and the collector and drain, coupled. C-reactive protein (CRP), which is an important disease marker in clinical examinations, can be detected using the proposed device. In the MOSFET-BJT hybrid mode, the sensitivity, selectivity, and reproducibility of the gated lateral BJT for biosensors were evaluated in this study. According to the results, in the MOSFET-BJT hybrid mode, the gated lateral BJT shows good selectivity and reproducibility. Changes in the emitter (source) current of the device for CRP antigen detection were approximately 0.65, 0.72, and 0.80 μA/decade at base currents of -50, -30, and -10 μA, respectively. The proposed device has significant application in the detection of certain biomaterials that require a dilution process using a common biosensor, such as a MOSFET-based biosensor. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Metamaterial devices for molding the flow of diffuse light (Conference Presentation)

    Science.gov (United States)

    Wegener, Martin

    2016-09-01

    Much of optics in the ballistic regime is about designing devices to mold the flow of light. This task is accomplished via specific spatial distributions of the refractive index or the refractive-index tensor. For light propagating in turbid media, a corresponding design approach has not been applied previously. Here, we review our corresponding recent work in which we design spatial distributions of the light diffusivity or the light-diffusivity tensor to accomplish specific tasks. As an application, we realize cloaking of metal contacts on large-area OLEDs, eliminating the contacts' shadows, thereby homogenizing the diffuse light emission. In more detail, metal contacts on large-area organic light-emitting diodes (OLEDs) are mandatory electrically, but they cast optical shadows, leading to unwanted spatially inhomogeneous diffuse light emission. We show that the contacts can be made invisible either by (i) laminate metamaterials designed by coordinate transformations of the diffusion equation or by (ii) triangular-shaped regions with piecewise constant diffusivity, hence constant concentration of scattering centers. These structures are post-optimized in regard to light throughput by Monte-Carlo ray-tracing simulations and successfully validated by model experiments.

  2. Single Atomically Sharp Lateral Monolayer p-n Heterojunction Solar Cells with Extraordinarily High Power Conversion Efficiency

    KAUST Repository

    Tsai, Meng-Lin

    2017-06-26

    The recent development of 2D monolayer lateral semiconductor has created new paradigm to develop p-n heterojunctions. Albeit, the growth methods of these heterostructures typically result in alloy structures at the interface, limiting the development for high-efficiency photovoltaic (PV) devices. Here, the PV properties of sequentially grown alloy-free 2D monolayer WSe-MoS lateral p-n heterojunction are explores. The PV devices show an extraordinary power conversion efficiency of 2.56% under AM 1.5G illumination. The large surface active area enables the full exposure of the depletion region, leading to excellent omnidirectional light harvesting characteristic with only 5% reduction of efficiency at incident angles up to 75°. Modeling studies demonstrate the PV devices comply with typical principles, increasing the feasibility for further development. Furthermore, the appropriate electrode-spacing design can lead to environment-independent PV properties. These robust PV properties deriving from the atomically sharp lateral p-n interface can help develop the next-generation photovoltaics.

  3. A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wei [College of Food Science and Engineering, Ocean University of China, Qingdao 266003 (China); Zhao, Shiming [Key Laboratory of Regenerative Biology, South China Institute for Stem Cell Biology and Regenerative Medicine, Guangzhou Institutes of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530 (China); Mao, Yiping [Yueyang Institute for Food and Drug Control, Yueyang 430198 (China); Fang, Zhiyuan [Affiliated Tumor Hospital of Guangzhou Medical University, Guangzhou 510095 (China); Lu, Xuewen [Key Laboratory of Regenerative Biology, South China Institute for Stem Cell Biology and Regenerative Medicine, Guangzhou Institutes of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530 (China); Zeng, Lingwen, E-mail: zeng6@yahoo.com [Key Laboratory of Regenerative Biology, South China Institute for Stem Cell Biology and Regenerative Medicine, Guangzhou Institutes of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530 (China)

    2015-02-25

    Highlights: • Limit of detection as low as 10 CFU mL{sup −1}Escherichia coli O157:H7. • No need of antibodies and substituted with aptamers. • Isothermal strand displacement amplification for signal amplification. • Results observed by the naked eye. • Great potential application in the area of food control. - Abstract: Foodborne diseases caused by pathogens are one of the major problems in food safety. Convenient and sensitive point-of-care rapid diagnostic tests for food-borne pathogens have been a long-felt need of clinicians. Commonly used methods for pathogen detection rely on conventional culture-based tests, antibody-based assays and polymerase chain reaction (PCR)-based techniques. These methods are costly, laborious and time-consuming. Herein, we present a simple and sensitive aptamer based biosensor for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7). In this assay, two different aptamers specific for the outmembrane of E. coli O157:H7 were used. One of the aptamers was used for magnetic bead enrichment, and the other was used as a signal reporter for this pathogen, which was amplified by isothermal strand displacement amplification (SDA) and further detected by a lateral flow biosensor. Only the captured aptamers on cell membrane were amplified, limitations of conventional DNA amplification based method such as false-positive can be largely reduced. The generated signals (red bands on the test zone of a lateral flow strip) can be unambiguously read out by the naked eye. As low as 10 colony forming units (CFU) of E. coli O157:H7 were detected in this study. Without DNA extraction, the reduced handling and simpler equipment requirement render this assay a simple and rapid alternative to conventional methods.

  4. A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification

    International Nuclear Information System (INIS)

    Wu, Wei; Zhao, Shiming; Mao, Yiping; Fang, Zhiyuan; Lu, Xuewen; Zeng, Lingwen

    2015-01-01

    Highlights: • Limit of detection as low as 10 CFU mL −1 Escherichia coli O157:H7. • No need of antibodies and substituted with aptamers. • Isothermal strand displacement amplification for signal amplification. • Results observed by the naked eye. • Great potential application in the area of food control. - Abstract: Foodborne diseases caused by pathogens are one of the major problems in food safety. Convenient and sensitive point-of-care rapid diagnostic tests for food-borne pathogens have been a long-felt need of clinicians. Commonly used methods for pathogen detection rely on conventional culture-based tests, antibody-based assays and polymerase chain reaction (PCR)-based techniques. These methods are costly, laborious and time-consuming. Herein, we present a simple and sensitive aptamer based biosensor for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7). In this assay, two different aptamers specific for the outmembrane of E. coli O157:H7 were used. One of the aptamers was used for magnetic bead enrichment, and the other was used as a signal reporter for this pathogen, which was amplified by isothermal strand displacement amplification (SDA) and further detected by a lateral flow biosensor. Only the captured aptamers on cell membrane were amplified, limitations of conventional DNA amplification based method such as false-positive can be largely reduced. The generated signals (red bands on the test zone of a lateral flow strip) can be unambiguously read out by the naked eye. As low as 10 colony forming units (CFU) of E. coli O157:H7 were detected in this study. Without DNA extraction, the reduced handling and simpler equipment requirement render this assay a simple and rapid alternative to conventional methods

  5. Extended result reading window in lateral flow tests detecting exposure to Onchocerca volvulus: a new technology to improve epidemiological surveillance tools.

    Directory of Open Access Journals (Sweden)

    Allison Golden

    Full Text Available Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov. An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%-92.0%, and specificity of 97% (95% confidence interval: 95.4%-98.6%. Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives. We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96. We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test.

  6. A novel technology: microfluidic devices for microbubble ultrasound contrast agent generation.

    Science.gov (United States)

    Lin, Hangyu; Chen, Junfang; Chen, Chuanpin

    2016-09-01

    Microbubbles are used as ultrasound contrast agents, which enhance ultrasound imaging techniques. In addition, microbubbles currently show promise in disease therapeutics. Microfluidic devices have increased the ability to produce microbubbles with precise size, and high monodispersity compared to microbubbles created using traditional methods. This paper will review several variations in microfluidic device structures used to produce microbubbles as ultrasound contrast agents. Microfluidic device structures include T-junction, and axisymmetric and asymmetric flow-focusing. These devices have made it possible to produce microbubbles that can enter the vascular space; these microbubbles must be less than 10 μm in diameter and have high monodispersity. For different demands of microbubbles production rate, asymmetric flow-focusing devices were divided into individual and integrated devices. In addition, asymmetric flow-focusing devices can produce double layer and multilayer microbubbles loaded with drug or biological components. Details on the mechanisms of both bubble formation and device structures are provided. Finally, microfluidically produced microbubble acoustic responses, microbubble stability, and microbubble use in ultrasound imaging are discussed.

  7. Quality Control Method for a Micro-Nano-Channel Microfabricated Device

    Science.gov (United States)

    Grattoni, Alessandro; Ferrari, Mauro; Li, Xuewu

    2012-01-01

    A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

  8. Distributed Power Flow Controller

    NARCIS (Netherlands)

    Yuan, Z.

    2010-01-01

    In modern power systems, there is a great demand to control the power flow actively. Power flow controlling devices (PFCDs) are required for such purpose, because the power flow over the lines is the nature result of the impedance of each line. Due to the control capabilities of different types of

  9. Patterned Arrays of Functional Lateral Heterostructures via Sequential Template-Directed Printing.

    Science.gov (United States)

    Li, Yifan; Su, Meng; Li, Zheng; Huang, Zhandong; Li, Fengyu; Pan, Qi; Ren, Wanjie; Hu, Xiaotian; Song, Yanlin

    2018-04-30

    The precise integration of microscale dots and lines with controllable interfacing connections is highly important for the fabrication of functional devices. To date, the solution-processible methods are used to fabricate the heterogeneous micropatterns for different materials. However, for increasingly miniaturized and multifunctional devices, it is extremely challenging to engineer the uncertain kinetics of a solution on the microstructures surfaces, resulting in uncontrollable interface connections and poor device performance. Here, a sequential template-directed printing process is demonstrated for the fabrication of arrayed microdots connected by microwires through the regulation of the Rayleigh-Taylor instability of material solution or suspension. Flexibility in the control of fluidic behaviors can realize precise interface connection between the micropatterns, including the microwires traversing, overlapping or connecting the microdots. Moreover, various morphologies such as circular, rhombic, or star-shaped microdots as well as straight, broken or curved microwires can be achieved. The lateral heterostructure printed with two different quantum dots displays bright dichromatic photoluminescence. The ammonia gas sensor printed by polyaniline and silver nanoparticles exhibits a rapid response time. This strategy can construct heterostructures in a facile manner by eliminating the uncertainty of the multimaterials interface connection, which will be promising for the development of novel lateral functional devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Microfluidic device for drug delivery

    Science.gov (United States)

    Beebe, David J. (Inventor); MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Mensing, Glennys A. (Inventor)

    2010-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  11. Provision and financing of assistive technology devices in Germany: a bureaucratic odyssey? The case of amyotrophic lateral sclerosis and Duchenne muscular dystrophy.

    Science.gov (United States)

    Henschke, Cornelia

    2012-05-01

    The regulations for financing assistive technology devices (ATDs) are complex and fragmented and, thus, might influence adequate provision of these devices to people who need multiple ATDs. This study aims to explore and analyze patients' problems with the provision and financing of ATDs for the following two rare diseases: amyotrophic lateral sclerosis (ALS) and Duchenne muscular dystrophy (DMD). A survey was conducted by means of semi-standardized questionnaires addressing the issues of coverage decisions for ATDs and problems with provision of ATDs. Information was retrieved from ALS (n=19) and DMD (n=14) patients. Conducted interviews were transcribed verbatim and analyzed using qualitative content analysis. Respondents experienced difficulties with the provision and financing of ATDs. They underlined problems such as long approval processes and a serious bureaucratic burden, which induced inadequate provision of ATDs. Experiences of ALS and DMD respondents frequently were similar, especially regarding financing decisions and the process of decision making by sickness funds. The results suggest that difficulties in receiving and financing ATDs are common problems among ALS and DMD patients. There is a need for an interdisciplinary approach in the provision of ATDs and their financing, which should be coordinated by case managers. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Biomimetic Flow Sensors

    NARCIS (Netherlands)

    Casas, J.; Liu, Chang; Krijnen, Gijsbertus J.M.

    2012-01-01

    Biomimetic flow sensors are biologically inspired devices that measure the speed and direction of fluids. This survey starts by describing the role and functioning of airflow-sensing hairs in arthropods and in fishes, carries on with the biomimetic MEMS implementations, both for air and water flow

  13. CONVECTIVE HEAT TRANSFER IN CYCLONE DEVICE WITH EXTERNAL GAS RECIRCULATION

    Directory of Open Access Journals (Sweden)

    S. V. Karpov

    2016-01-01

    Full Text Available The article considers the convective heat transfer on the surface of a hollow cylinder or several billets in a cyclone device with the new principle of external gas recirculation. According to this principle, transport of coolant from the lateral surface of the chamber, where the temperature is the highest, in the axial region is being fulfilled due to the pressure drop between the wall and axial areas of cyclonic flow. Dependency analysis of average and local heat transfer coefficients from operational and geometrical parameters has been performed; the generalized similarity equations for the calculation of the latter have been suggested. It is demonstrated that in case of download of a cyclone chamber with several billets, the use of the considered scheme of the external recirculation due to the specific characteristics of aerodynamics practically does not lead to noticeable changes in the intensity of convective heat transfer. Both experimental data and the numerical simulation results obtained with the use of OpenFOAM platform were used in the work. The investigations fulfilled will expand the area of the use of cyclone heating devices.

  14. Effects of structure and oxygen flow rate on the photo-response of amorphous IGZO-based photodetector devices

    Science.gov (United States)

    Jang, Jun Tae; Ko, Daehyun; Choi, Sungju; Kang, Hara; Kim, Jae-Young; Yu, Hye Ri; Ahn, Geumho; Jung, Haesun; Rhee, Jihyun; Lee, Heesung; Choi, Sung-Jin; Kim, Dong Myong; Kim, Dae Hwan

    2018-02-01

    In this study, we investigated how the structure and oxygen flow rate (OFR) during the sputter-deposition affects the photo-responses of amorphous indium-gallium-zinc-oxide (a-IGZO)-based photodetector devices. As the result of comparing three types of device structures with one another, which are a global Schottky diode, local Schottky diode, and thin-film transistor (TFT), the IGZO TFT with the gate pulse technique suppressing the persistent photoconductivity (PPC) is the most promising photodetector in terms of a high photo-sensitivity and uniform sensing characteristic. In order to analyze the IGZO TFT-based photodetectors more quantitatively, the time-evolution of sub-gap density-of-states (DOS) was directly observed under photo-illumination and consecutively during the PPC-compensating period with applying the gate pulse. It shows that the increased ionized oxygen vacancy (VO2+) defects under photo-illumination was fully recovered by the positive gate pulse and even overcompensated by additional electron trapping. Based on experimentally extracted sub-gap DOS, the origin on PPC was successfully decomposed into the hole trapping and the VO ionization. Although the VO ionization is enhanced in lower OFR (O-poor) device, the PPC becomes more severe in high OFR (O-rich) device because the hole trapping dominates the PPC in IGZO TFT under photo-illumination rather than the VO ionization and more abundant holes are trapped into gate insulator and/or interface in O-rich TFTs. Similarly, the electron trapping during the PPC-compensating period with applying the positive gate pulse becomes more prominent in O-rich TFTs. It is attributed to more hole/electron traps in the gate insulator and/or interface, which is associated with oxygen interstitials, or originates from the ion bombardment-related lower quality gate oxide in O-rich devices.

  15. DETERMINATION OF CHARACTERISTICS OF THROTTLING DEVICE FOR PNEUMATIC SPRING

    Directory of Open Access Journals (Sweden)

    O. H. Reidemeister

    2018-02-01

    Full Text Available Purpose. This paper focuses on determination of the dependence of the working medium flow on the capacity of the throttling device, its geometric features and the pressure difference in the pneumatic spring cylinder and in the auxiliary reservoir. Methodology. Calculation of the dependence of the working medium and pressure drop is performed in two ways: 1 by numerical simulation of a stationary gas flow through a throttling element; 2 its analytical calculation expression using empirical relationships (control calculation to evaluate the reliability of numerical simulation results. For the calculation, three models of throttling devices were chosen. Dependence of the flow rate of the working medium on the capacity of the throttling device and its geometric features was determined based on the approximation of the dependency graphs of the pressure drop against the mass flow rate of the working medium. Findings. We obtained graphical dependencies between the pressure drop and the mass flow rate of the working medium from the two calculation options. Based on the results of calculations performed with the help of a software package with visualization of the results, we calculated a proportionality coefficient that describes the dependence of the working medium flow on the throttling device capacity and its geometric features for each of the throttling elements considered, with three degrees of closure. The air flow values, obtained by numerical simulation, are greater than the flow rates obtained from semi-empirical formulas. At the same time, they are in good qualitative agreement, and the quantitative difference averages 25%, which can be regarded as confirmation of the reliability of the nu-merical model. Based on the calculation results, we plotted the proportionality coefficient graphs against the degree of closure of the throttling device. Originality. The work allows determining the degree of influence of the frictio-nal component on the

  16. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  17. Controlled synthesis of poly(3-hexylthiophene in continuous flow

    Directory of Open Access Journals (Sweden)

    Helga Seyler

    2013-07-01

    Full Text Available There is an increasing demand for organic semiconducting materials with the emergence of organic electronic devices. In particular, large-area devices such as organic thin-film photovoltaics will require significant quantities of materials for device optimization, lifetime testing and commercialization. Sourcing large quantities of materials required for the optimization of large area devices is costly and often impossible to achieve. Continuous-flow synthesis enables straight-forward scale-up of materials compared to conventional batch reactions. In this study, poly(3-hexylthiophene, P3HT, was synthesized in a bench-top continuous-flow reactor. Precise control of the molecular weight was demonstrated for the first time in flow for conjugated polymers by accurate addition of catalyst to the monomer solution. The P3HT samples synthesized in flow showed comparable performance to commercial P3HT samples in bulk heterojunction solar cell devices.

  18. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  19. Self compensating fire detection device

    International Nuclear Information System (INIS)

    Cholin, J. M.

    1985-01-01

    A device employing ionization principles for fire detection disclosing a configuration which allows compensation for adverse effects due to the flow of the gas through the device or due to the accumulation of dust and dirt therein. The detecting device includes two ionization chambers, each having a first member, such as a cylindrically shaped cup, having first and second conductive surface portions. Each chamber also incudes a second member, such as a circular, electrode disc having two conductive surface portions. There is disposed in each chamber a radioactive source for ionizing the gas in the volumes intervening between respective pairs of surfaces. The area dimensions of the respective pairs of surfaces, the interventing volumes and the distances there between, and the relative orientation of the respective pairs are calculated and placed such that the ionization currents flowing between pairs of conductive surfaces are substantially equal and orthogonal to each other

  20. A new device for intraoperative renal blood flow measurement during open-heart surgery: an experimental study and the clinical pilot study.

    Science.gov (United States)

    Tirilomis, Theodor; Popov, Aron F; Hanekop, Gunnar G; Braeuer, Anselm; Quintel, Michael; Schoendube, Friedrich A; Friedrich, Martin G

    2013-10-01

    Renal blood flow (RBF) may vary during cardiopulmonary bypass and low flow may cause insufficient blood supply of the kidney triggering renal failure postoperatively. Still, a valid intraoperative method of continuous RBF measurement is not available. A new catheter combining thermodilution and intravascular Doppler was developed, first calibrated in an in vitro model, and the catheter specific constant was determined. Then, application of the device was evaluated in a pilot study in an adult cardiovascular population. The data of the clinical pilot study revealed high correlation between the flow velocities detected by intravascular Doppler and the RBF measured by thermodilution (Pearson's correlation range: 0.78 to 0.97). In conclusion, the RBF can be measured excellently in real time using the new catheter, even under cardiopulmonary bypass. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  1. Tailoring strain in microelectronic devices

    NARCIS (Netherlands)

    van Hemert, T.

    2013-01-01

    The central device of this thesis is the transistor. It acts like a faucet, but hen for electric charge. There is a connection that is called the source, just like the water company. And the charge flows into the drain. Finally there is a handle, here called the gate, to control the flow of charge.

  2. Progress report on INEL full flow drag screen

    International Nuclear Information System (INIS)

    Arave, A.E.; Colson, J.B.; Fincke, J.R.

    1977-01-01

    The objective in developing a full flow drag screen is to obtain a total momentum flux measurement which when combined with a suitable independent velocity or density measurement will yield a total mass flux. The major design considerations are predicated by the fact that an accurate momentum flux measurement must be made over a wide range of flow conditions. The device should exhibit a constant calibration regardless of Reynolds number, void fraction, slip ratio, or flow regime. The dynamics of drag devices are well understood in single-phase flows. This is not true for two-phase flows. The present development program is directed toward gaining an understanding of the dynamics of drag devices which sample the total area of a pipe in two-phase flow and developing a method for deducing mass flow rate using such a device. Various geometric arrangements are to be investigated. Testing to date has shown excellent results using a round wire mesh screen in the Semiscale air/water loop. Future air/water testing will include perforated plates and wire meshes with both rectangular and diamond shaped cross sections. Analytical models of the hydrodynamics of the drag screen as well as the associated density or velocity measuring device are being used to select the optimum configuration. Alternate force sensing methods are also being considered. These include single and multiple transducer arrangements. Multistage springs and pressure drop across the body are to be evaluated for extending the dynamic range of the drag body

  3. Self-organized anisotropic strain engineering for lateral quantum dot ordering

    NARCIS (Netherlands)

    Nötzel, R.; Schmidt, O.G.

    2007-01-01

    Lateral ordering of semiconductor quantum dots (QDs) of high quality in well-defined arrangements is essential for the realization of future quantum functional devices with applications in solid state quantum computing and quantum communication [1]. We have developed a new concept for the creation

  4. Lateral Flow Immunoassays for Ebola Virus Disease Detection in Liberia.

    Science.gov (United States)

    Phan, Jill C; Pettitt, James; George, Josiah S; Fakoli, Lawrence S; Taweh, Fahn M; Bateman, Stacey L; Bennett, Richard S; Norris, Sarah L; Spinnler, David A; Pimentel, Guillermo; Sahr, Phillip K; Bolay, Fatorma K; Schoepp, Randal J

    2016-10-15

    Lateral flow immunoassays (LFIs) are point-of-care diagnostic assays that are designed for single use outside a formal laboratory, with in-home pregnancy tests the best-known example of these tests. Although the LFI has some limitations over more-complex immunoassay procedures, such as reduced sensitivity and the potential for false-positive results when using complex sample matrices, the assay has the benefits of a rapid time to result and ease of use. These benefits make it an attractive option for obtaining rapid results in an austere environment. In an outbreak of any magnitude, a field-based rapid diagnostic assay would allow proper patient transport and for safe burials to be conducted without the delay caused by transport of samples between remote villages and testing facilities. Use of such point-of-care instruments in the ongoing Ebola virus disease (EVD) outbreak in West Africa would have distinct advantages in control and prevention of local outbreaks, but proper understanding of the technology and interpretation of results are important. In this study, a LFI, originally developed by the Naval Medical Research Center for Ebola virus environmental testing, was evaluated for its ability to detect the virus in clinical samples in Liberia. Clinical blood and plasma samples and post mortem oral swabs submitted to the Liberian Institute for Biomedical Research, the National Public Health Reference Laboratory for EVD testing, were tested and compared to results of real-time reverse transcription-polymerase chain reaction (rRT-PCR), using assays targeting Ebola virus glycoprotein and nucleoprotein. The LFI findings correlated well with those of the real-time RT-PCR assays used as benchmarks. Rapid antigen-detection tests such as LFIs are attractive alternatives to traditional immunoassays but have reduced sensitivity and specificity, resulting in increases in false-positive and false-negative results. An understanding of the strengths, weaknesses, and

  5. Analysis and simulation of semiconductor devices

    CERN Document Server

    Selberherr, Siegfried

    1984-01-01

    The invention of semiconductor devices is a fairly recent one, considering classical time scales in human life. The bipolar transistor was announced in 1947, and the MOS transistor, in a practically usable manner, was demonstrated in 1960. From these beginnings the semiconductor device field has grown rapidly. The first integrated circuits, which contained just a few devices, became commercially available in the early 1960s. Immediately thereafter an evolution has taken place so that today, less than 25 years later, the manufacture of integrated circuits with over 400.000 devices per single chip is possible. Coincident with the growth in semiconductor device development, the literature concerning semiconductor device and technology issues has literally exploded. In the last decade about 50.000 papers have been published on these subjects. The advent of so called Very-Large-Scale-Integration (VLSI) has certainly revealed the need for a better understanding of basic device behavior. The miniaturization of the s...

  6. Hydrocode analysis of lateral stress gauges in shocked tantalum

    International Nuclear Information System (INIS)

    Harris, E. J.; Winter, R. E.

    2007-01-01

    Experiments published by other workers, on the resistance change of manganin stress gauges embedded in a lateral orientation in tantalum targets shocked to a range of stresses, have been analysed using an adaptive mesh refinement hydrocode. It was found that for all of the four experiments the shape of the time profile of the computed lateral stress in the mounting layer closely matched the shape of the experimental lateral stress profiles. However, the calculated lateral stresses at the gauge location in the mounting layer are significantly less than the lateral stresses that would have been produced in the target if no gauge had been present. The perturbation caused by the gauge increased as the strength of the applied shock increased. When the perturbations are taken into account values of flow stress that are significantly smaller than those reported in the original research paper are derived. The work shows that the lateral gauge technique can give valuable information on strength provided high resolution simulation is used to compensate for the perturbations caused by the gauges

  7. Phloem-sap-dynamics sensor device for monitoring photosynthates transportation in plant shoots

    Science.gov (United States)

    Yano, Yuya; Ono, Akihito; Terao, Kyohei; Suzuki, Takaaki; Takao, Hidekuni; Kobayashi, Tsuyoshi; Kataoka, Ikuo; Shimokawa, Fusao

    2018-06-01

    We propose a microscale phloem-sap-dynamics sensor device to obtain the index of an internal plant condition regarding the transportation of primary photosynthates in phloem, which is an essential indicator of stable crop production under controlled-growth environments. In detail, we integrated a conventional Granier sensor with a thermal-flow sensor and devised an improved sensor device to quantify such index, including the information on velocity and direction of the phloem-sap flow using the microelectromechanical systems (MEMS) technology. The experimental results showed that although the proposed sensor device was approximately only 1/10 the size of the conventional Granier sensor, it could generate an output nearly equal to that of the conventional sensor. Furthermore, experiments using mimicked plants demonstrated that the proposed device could measure minute flow velocities in the range of 0–200 µm/s, which are generally known as the phloem-sap flow velocity, and simultaneously detect the flow direction.

  8. Topology optimization of flow problems

    DEFF Research Database (Denmark)

    Gersborg, Allan Roulund

    2007-01-01

    This thesis investigates how to apply topology optimization using the material distribution technique to steady-state viscous incompressible flow problems. The target design applications are fluid devices that are optimized with respect to minimizing the energy loss, characteristic properties...... transport in 2D Stokes flow. Using Stokes flow limits the range of applications; nonetheless, the thesis gives a proof-of-concept for the application of the method within fluid dynamic problems and it remains of interest for the design of microfluidic devices. Furthermore, the thesis contributes...... at the Technical University of Denmark. Large topology optimization problems with 2D and 3D Stokes flow modeling are solved with direct and iterative strategies employing the parallelized Sun Performance Library and the OpenMP parallelization technique, respectively....

  9. Function Lateralization via Measuring Coherence Laterality

    Science.gov (United States)

    Wang, Ze; Mechanic-Hamilton, Dawn; Pluta, John; Glynn, Simon; Detre, John A.

    2009-01-01

    A data-driven approach for lateralization of brain function based on the spatial coherence difference of functional MRI (fMRI) data in homologous regions-of-interest (ROI) in each hemisphere is proposed. The utility of using coherence laterality (CL) to determine function laterality was assessed first by examining motor laterality using normal subjects’ data acquired both at rest and with a simple unilateral motor task and subsequently by examining mesial temporal lobe memory laterality in normal subjects and patients with temporal lobe epilepsy. The motor task was used to demonstrate that CL within motor ROI correctly lateralized functional stimulation. In patients with unilateral epilepsy studied during a scene-encoding task, CL in a hippocampus-parahippocampus-fusiform (HPF) ROI was concordant with lateralization based on task activation, and the CL index (CLI) significantly differentiated the right side group to the left side group. By contrast, normal controls showed a symmetric HPF CLI distribution. Additionally, similar memory laterality prediction results were still observed using CL in epilepsy patients with unilateral seizures after the memory encoding effect was removed from the data, suggesting the potential for lateralization of pathological brain function based on resting fMRI data. A better lateralization was further achieved via a combination of the proposed approach and the standard activation based approach, demonstrating that assessment of spatial coherence changes provides a complementary approach to quantifying task-correlated activity for lateralizing brain function. PMID:19345736

  10. Capturing device for radioactive corrosion products

    International Nuclear Information System (INIS)

    Ono, Kiyoshi.

    1987-01-01

    Purpose: To render the flow channel area uniform for each of coolants over the entire capturing device and reduce the corrosion of capturing materials due to coolants. Constitution: Most of radioactivity caused by radioactive corrosion products are due to Mn-54 radioactive nuclides and it has been known that the nuclides are readily deposited to the surface of nickel material in sodium at high temperature. It is difficult in a conventional capturing device constituted by winding a nickel plate fabricated with protrusions in a multiple-coaxial configuration, that the flow channel area is reduced in a portion of the flow channel and it is difficult to make the flow of the coolants uniform. In view of the above, by winding a nickel plate having a plurality of protrusions at the surface formed integrally by way of an electrolytic process into a multiple-coaxial or spiral shape, those having high resistance to the coolant corrosion can be obtained. (Takahashi, M.)

  11. Preliminary design of the internal geometry in a minimally invasive left ventricular assist device under pulsatile-flow conditions.

    Science.gov (United States)

    Smith, P Alex; Wang, Yaxin; Metcalfe, Ralph W; Sampaio, Luiz C; Timms, Daniel L; Cohn, William E; Frazier, O H

    2018-03-01

    A minimally invasive, partial-assist, intra-atrial blood pump has been proposed, which would unload the left ventricle with a flow path from the left atrium to the arterial system. Flow modulation is a common strategy for ensuring washout in the pump, but it can increase power consumption because it is typically achieved through motor-speed variation. However, if a pump's performance curve had the proper gradient, flow modulation could be realized passively. To achieve this goal, we propose a pump performance operating curve as an alternative to the more standard operating point. Mean-line theory was employed to generate an initial set of geometries that were then tested on a hydraulic test rig at ~20,000 r/min. Experimental results show that the intra-atrial blood pump performed below the operating region; however, it was determined that smaller hub diameter and longer chord length bring the performance of the intra-atrial blood pump device closer to the operating curve. We found that it is possible to shape the pump performance curve for specifically targeted gradients over the operating region through geometric variations inside the pump.

  12. Nonlinear dynamics of a rack-pinion-rack device powered by the Casimir force.

    Science.gov (United States)

    Miri, MirFaez; Nekouie, Vahid; Golestanian, Ramin

    2010-01-01

    Using the lateral Casimir force-a manifestation of the quantum fluctuations of the electromagnetic field between objects with corrugated surfaces-as the main force transduction mechanism, a nanomechanical device with rich dynamical behaviors is proposed. The device is made of two parallel racks that are moving in the same direction and a pinion in the middle that couples with both racks via the noncontact lateral Casimir force. The built-in frustration in the device causes it to be very sensitive and react dramatically to minute changes in the geometrical parameters and initial conditions of the system. The noncontact nature of the proposed device could help with the ubiquitous wear problem in nanoscale mechanical systems.

  13. Turbulent mixing between subchannels in a gas-liquid two-phase flow. For the equilibrium flow without net fluid transfer between subchannels

    International Nuclear Information System (INIS)

    Kawahara, Akimaro; Sadatomi, Michio; Sato, Yoshifusa; Saito, Hidetoshi.

    1995-01-01

    To provide data necessary for modeling turbulent mixing between subchannels in a nuclear fuel rod bundle, three experiments were made in series for equilibrium two-phase flows, in which net mass exchange does not occur between subchannels for each phase. The first one was the measurement of turbulent mixing rates of both gas and liquid phases by a tracer technique, using air and water as the working fluids. Three kinds of vertical test channels consisting of two subchannels were used. The data have shown that the turbulent mixing rate of each phase in a two-phase flow is strongly dependent on flow regime. So, to see the relation between turbulent mixing and two-phase flow configuration in the subchannels, the second experiment, flow visualization, was made. It was observed in slug and churn flows that a lateral inter-subchannel liquid flow of a large scale is caused by the successive axial transit of large gas bubbles in each subchannel, and the turbulent mixing for the liquid phase is dominated by this lateral flow. To investigate a driving force of such large scale lateral flow, the third experiment, the measurement of an instantaneous pressure differential between the subchannels, was made. The result showed that there is a close relationship between the liquid phase mixing rate and the magnitude of the pressure differential fluctuation. (author)

  14. Single-mode very wide tunability in laterally coupled semiconductor lasers with electrically controlled reflectivities

    Science.gov (United States)

    Griffel, Giora; Chen, Howard Z.; Grave, Ilan; Yariv, Amnon

    1991-04-01

    The operation of a novel multisection structure comprised of laterally coupled gain-guided semiconductor lasers is demonstrated. It is shown that tunable single longitudinal mode operation can be achieved with a high degree of frequency selectivity. The device has a tuning range of 14.5 nm, the widest observed to date in a monolithic device.

  15. Factors associated with anti-human leukocyte antigen antibodies in patients supported with continuous-flow devices and effect on probability of transplant and post-transplant outcomes

    DEFF Research Database (Denmark)

    Alba, Ana C; Tinckam, Kathryn; Foroutan, Farid

    2015-01-01

    BACKGROUND: One major disadvantage of ventricular assist device (VAD) therapy is the development of human-leukocyte antigen (HLA) antibodies. We aimed to identify factors associated with HLA antibodies during continuous flow (CF)-VAD support and assess the effect on transplant probability...

  16. Silicon microfluidic flow focusing devices for the production of size-controlled PLGA based drug loaded microparticles.

    Science.gov (United States)

    Keohane, Kieran; Brennan, Des; Galvin, Paul; Griffin, Brendan T

    2014-06-05

    The increasing realisation of the impact of size and surface properties on the bio-distribution of drug loaded colloidal particles has driven the application of micro fabrication technologies for the precise engineering of drug loaded microparticles. This paper demonstrates an alternative approach for producing size controlled drug loaded PLGA based microparticles using silicon Microfluidic Flow Focusing Devices (MFFDs). Based on the precise geometry and dimensions of the flow focusing channel, microparticle size was successfully optimised by modifying the polymer type, disperse phase (Qd) flow rate, and continuous phase (Qc) flow rate. The microparticles produced ranged in sizes from 5 to 50 μm and were highly monodisperse (coefficient of variation <5%). A comparison of Ciclosporin (CsA) loaded PLGA microparticles produced by MFFDs vs conventional production techniques was also performed. MFFDs produced microparticles with a narrower size distribution profile, relative to the conventional approaches. In-vitro release kinetics of CsA was found to be influenced by the production technique, with the MFFD approach demonstrating the slowest rate of release over 7 days (4.99 ± 0.26%). Finally, MFFDs were utilised to produce pegylated microparticles using the block co-polymer, PEG-PLGA. In contrast to the smooth microparticles produced using PLGA, PEG-PLGA microparticles displayed a highly porous surface morphology and rapid CsA release, with 85 ± 6.68% CsA released after 24h. The findings from this study demonstrate the utility of silicon MFFDs for the precise control of size and surface morphology of PLGA based microparticles with potential drug delivery applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Subthreshold Current and Swing Modeling of Gate Underlap DG MOSFETs with a Source/Drain Lateral Gaussian Doping Profile

    Science.gov (United States)

    Singh, Kunal; Kumar, Sanjay; Goel, Ekta; Singh, Balraj; Kumar, Mirgender; Dubey, Sarvesh; Jit, Satyabrata

    2017-01-01

    This paper proposes a new model for the subthreshold current and swing of the short-channel symmetric underlap ultrathin double gate metal oxide field effect transistors with a source/drain lateral Gaussian doping profile. The channel potential model already reported earlier has been utilized to formulate the closed form expression for the subthreshold current and swing of the device. The effects of the lateral straggle and geometrical parameters such as the channel length, channel thickness, and oxide thickness on the off current and subthreshold slope have been demonstrated. The devices with source/drain lateral Gaussian doping profiles in the underlap structure are observed to be highly resistant to short channel effects while improving the current drive. The proposed model is validated by comparing the results with the numerical simulation data obtained by using the commercially available ATLAS™, a two-dimensional (2-D) device simulator from SILVACO.

  18. Effect of Pneumoperitoneum and Lateral Position on Oropharyngeal Seal Pressures of Proseal LMA in Laparoscopic Urological Procedures.

    Science.gov (United States)

    Rustagi, Preeti; Patkar, Geeta A; Ourasang, Anil Kumar; Tendolkar, Bharati A

    2017-02-01

    A sustained and effective oropharyngeal sealing with supraglottic airway is required to maintain the ventilation during laparoscopic surgery. Previous studies have observed the Oropharyngeal Seal Pressure (OSP) for Proseal Laryngeal Mask Airway (PLMA) after pneumoperitoneum in supine and trendelenburg position, where PLMA was found to be an effective airway device. This study was conducted with ProSeal LMA, for laparoscopic Urologic procedures done in lateral position. To measure OSP in supine and lateral position and to observe the effect of pneumoperitoneum in lateral position on OSP. Secondary objectives were to assess adequacy of ventilation and incidence of adverse events. A total number of 25 patients of American Society of Anaesthesiologists (ASA) physical status II and I were enrolled. After induction of anaesthesia using a standardized protocol, PLMA was inserted. Ryle's tube was inserted through drain tube. The position of PLMA was confirmed with ease of insertion of Ryle's tube and fibreoptic grading of vocal cords. Patients were then put in lateral position. The OSP was measured in supine position. This value was baseline comparison for OSP in lateral position and that after pneumoperitoneum. We assessed the efficacy of PLMA for ventilation, after carboperitoneum in lateral position (peak airway pressure, End Tidal Carbon dioxide (EtCO 2 ), SPO 2 ). Incidence of adverse effects (displacement of device, gastric insufflation, regurgitation, coughing, sore throat, blood on device, trauma) was also noted. The OSP was above Peak Airway Pressure (PAP) in supine (22.1±5.4 and 15.4±4.49cm of H 2 O) and lateral position (22.6±5.3 and 16.1±4.6). After pneumoperitoneum, which was in lateral position, there was statistically significant (p-value <0.05) increase in both PAP (19.96±4.015) and OSP (24.32±4.98, p-value 0.03). There was no intraoperative displacement of PLMA. There was no event of suboptimal oxygenation. EtCO 2 was always within normal limits

  19. Parametric Optimization of Lateral NIPIN Phototransistors for Flexible Image Sensors

    Directory of Open Access Journals (Sweden)

    Min Seok Kim

    2017-08-01

    Full Text Available Curved image sensors, which are a key component in bio-inspired imaging systems, have been widely studied because they can improve an imaging system in various aspects such as low optical aberrations, small-form, and simple optics configuration. Many methods and materials to realize a curvilinear imager have been proposed to address the drawbacks of conventional imaging/optical systems. However, there have been few theoretical studies in terms of electronics on the use of a lateral photodetector as a flexible image sensor. In this paper, we demonstrate the applicability of a Si-based lateral phototransistor as the pixel of a high-efficiency curved photodetector by conducting various electrical simulations with technology computer aided design (TCAD. The single phototransistor is analyzed with different device parameters: the thickness of the active cell, doping concentration, and structure geometry. This work presents a method to improve the external quantum efficiency (EQE, linear dynamic range (LDR, and mechanical stability of the phototransistor. We also evaluated the dark current in a matrix form of phototransistors to estimate the feasibility of the device as a flexible image sensor. Moreover, we fabricated and demonstrated an array of phototransistors based on our study. The theoretical study and design guidelines of a lateral phototransistor create new opportunities in flexible image sensors.

  20. Reducing leakage current in semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Bin; Matioli, Elison de Nazareth; Palacios, Tomas Apostol

    2018-03-06

    A semiconductor device includes a first region having a first semiconductor material and a second region having a second semiconductor material. The second region is formed over the first region. The semiconductor device also includes a current blocking structure formed in the first region between first and second terminals of the semiconductor device. The current blocking structure is configured to reduce current flow in the first region between the first and second terminals.

  1. Microfluidic flow fractionation device for label-free isolation of circulating tumor cells (CTCs) from breast cancer patients.

    Science.gov (United States)

    Hyun, Kyung-A; Kwon, Kiho; Han, Hyunju; Kim, Seung-Il; Jung, Hyo-Il

    2013-02-15

    Circulating tumor cells (CTCs) are dissociated from primary tumor and circulate in peripheral blood. They are regarded as the genesis of metastasis. Isolation and enumeration of CTCs serve as valuable tools for cancer prognosis and diagnosis. However, the rarity and heterogeneity of CTCs in blood makes it difficult to separate intact CTCs without loss. In this paper, we introduce a parallel multi-orifice flow fractionation (p-MOFF) device in which a series of contraction/expansion microchannels are placed parallel on a chip forming four identical channels. CTCs were continuously isolated from the whole blood of breast cancer patients by hydrodynamic forces and cell size differences. Blood samples from 24 breast cancer patients were analyzed (half were from metastatic breast cancer patients and the rest were from adjuvant breast cancer patients). The number of isolated CTCs varied from 0 to 21 in 7.5 ml of blood. Because our devices do not require any labeling processes (e.g., EpCAM antibody), heterogeneous CTCs can be isolated regardless of EpCAM expression. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Flow distribution in the inlet plenum of steam generator

    International Nuclear Information System (INIS)

    Khadamakar, H.P.; Patwardhan, A.W.; Padmakumar, G.; Vaidyanathan, G.

    2011-01-01

    Highlights: → Various flow distribution devices have been studied to make the flow distribution uniform in axial as well as tangential direction. → Experiments were performed using Ultrasonic Velocity Profiler (UVP) and Particle Image Velocimetry (PIV). → CFD modeling has been carried out to give more insights. → Various flow distribution devices have been compared. - Abstract: The flow distribution in a 1/5th and 1/8th scale models of inlet plenum of steam generator (SG) has been studied by a combination of experiments and Computational Fluid Dynamics (CFD) simulations. The distribution of liquid sodium in the inlet plenum of the SG strongly affects the thermal as well as mechanical performance of the steam generator. Various flow distribution devices have been used to make the flow distribution uniform in axial as well as tangential direction in the window region. Experiments have been conducted to measure the radial velocity distribution using Ultrasonic Velocity Profiler (UVP) and Particle Image Velocimetry (PIV) under a variety of conditions. CFD modeling has been carried out for various configurations to give more insight into the flow distribution phenomena. The various flow distribution devices have been compared on the basis of a non-uniformity index parameter.

  3. Radioactive gas waste processing device

    International Nuclear Information System (INIS)

    Soma, Koichi.

    1996-01-01

    The present invention concerns a radioactive gas waste processing device which extracts exhaust gases from a turbine condensator in a BWR type reactor and releases them after decaying radioactivity thereof during temporary storage. The turbine condensator is connected with an extracting ejector, a preheater, a recombiner for converting hydrogen gas into steams, an off gas condensator for removing water content, a flow rate control valve, a dehumidifier, a hold up device for removing radiation contaminated materials, a vacuum pump for sucking radiation decayed-off gases, a circulation water tank for final purification and an exhaustion cylinder by way of connection pipelines in this order. An exhaust gas circulation pipeline is disposed to circulate exhaust gases from an exhaust gas exit pipeline of the recycling water tank to an exhaust gas exit pipeline of the exhaust gas condensator, and a pressure control valve is disposed to the exhaust gas circulation pipeline. This enable to perform a system test for the dehumidification device under a test condition approximate to the load of the dehumidification device under actual operation state, and stabilize both of system flow rate and pressure. (T.M.)

  4. ANSYS-MATLAB co-simulation of mucus flow distribution and clearance effectiveness of a new simulated cough device.

    Science.gov (United States)

    Ren, Shuai; Shi, Yan; Cai, Maolin; Zhao, Hongmei; Zhang, Zhaozhi; Zhang, Xiaohua Douglas

    2018-03-05

    Coughing is an irritable reaction that protects the respiratory system from infection and improves mucus clearance. However, for the patients who cannot cough autonomously, an assisted cough device is essential for mucus clearance. Considering the low efficiency of current assisted cough devices, a new simulated cough device based on the pneumatic system is proposed in this paper. Given the uncertainty of airflow rates necessary to clear mucus from airways, the computational fluid dynamics Eulerian wall film model and cough efficiency (CE) were used in this study to simulate the cough process and evaluate cough effectiveness. The Ansys-Matlab co-simulation model was set up and verified through experimental studies using Newtonian fluids. Next, model simulations were performed using non-Newtonian fluids, and peak cough flow (PCF) and PCF duration time were analyzed to determine their influence on mucus clearance. CE growth rate (λ) was calculated to reflect the CE variation trend. From the numerical simulation results, we find that CE rises as PCF increases while the growth rate trends to slow as PCF increases; when PCF changes from 60 to 360 L/min, CE changes from 3.2% to 51.5% which is approximately 16 times the initial value. Meanwhile, keeping a long PCF duration time could greatly improve CE under the same cough expired volume and PCF. The results indicated that increasing the PCF and PCF duration time can improve the efficiency of mucus clearance. This paper provides a new approach and a research direction for control strategy in simulated cough devices for airway mucus clearance. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Multi-layer micro/nanofluid devices with bio-nanovalves

    Science.gov (United States)

    Li, Hao; Ocola, Leonidas E.; Auciello, Orlando H.; Firestone, Millicent A.

    2013-01-01

    A user-friendly multi-layer micro/nanofluidic flow device and micro/nano fabrication process are provided for numerous uses. The multi-layer micro/nanofluidic flow device can comprise: a substrate, such as indium tin oxide coated glass (ITO glass); a conductive layer of ferroelectric material, preferably comprising a PZT layer of lead zirconate titanate (PZT) positioned on the substrate; electrodes connected to the conductive layer; a nanofluidics layer positioned on the conductive layer and defining nanochannels; a microfluidics layer positioned upon the nanofluidics layer and defining microchannels; and biomolecular nanovalves providing bio-nanovalves which are moveable from a closed position to an open position to control fluid flow at a nanoscale.

  6. Effectiveness of chest compression feedback during cardiopulmonary resuscitation in lateral tilted and semirecumbent positions: a randomised controlled simulation study.

    Science.gov (United States)

    Song, Y; Oh, J; Chee, Y; Cho, Y; Lee, S; Lim, T H

    2015-11-01

    Feedback devices have been shown to improve the quality of chest compression during cardiopulmonary resuscitation for patients in the supine position, but no studies have reported the effects of feedback devices on chest compression when the chest is tilted. Basic life support-trained providers were randomly assigned to administer chest compressions to a manikin in the supine, 30° left lateral tilt and 30° semirecumbent positions, with or without the aid of a feedback device incorporated into a smartphone. Thirty-six participants were studied. The feedback device did not affect the quality of chest compressions in the supine position, but improved aspects of performance in the tilted positions. In the lateral tilted position, the median (IQR [range]) chest compression rate was 99 (99-100 [96-117]) compressions.min(-1) with and 115 (95-128 [77-164]) compressions.min(-1) without feedback (p = 0.05), and the proportion of compressions of correct depth was 55 (0-96 [0-100])% with and 1 (0-30 [0-100])% without feedback (p = 0.03). In the semirecumbent position, the proportion of compressions of correct depth was 21 (0-87 [0-100])% with and 1 (0-26 [0-100])% without feedback (p = 0.05). Female participants applied chest compressions at a more accurate rate using the feedback device in the lateral tilted position but were unable to increase the chest compression depth, whereas male participants were able to increase the force of chest compression using the feedback device in the lateral tilted and semirecumbent positions. We conclude that a feedback device improves the application of chest compressions during simulated cardiopulmonary resuscitation when the chest is tilted. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  7. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Device to test the leak-tightness of a container

    International Nuclear Information System (INIS)

    Mills, A.E.; Davey, P.G.

    1978-01-01

    A device is described by which the sensitivity and exactness leak detectors with flow meters may be increased. For this, the flow meter is equipped with two thermal flow sensers and one heating element acting on the two sensors. (RW) [de

  9. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Method and device for characterization of two-phase flow in pipes

    International Nuclear Information System (INIS)

    Skarsvaag, K.; Sunde, A.J.

    1993-01-01

    Gamma radiation transmission measurements are made with one-shot-collimation to determine the distribution of voids within a gas-liquid mixture flowing in a pipe. The distribution of voids in selected portions of the pipe, taken together with statistical and logical tests applied thereto, provides information from which are determined: type of flow pattern or flow regime, the profile of a large gas bubble in slug flow, and the gas and the liquid volume flow rates in slug flow. 4 refs

  11. The flexural stiffness of superficial neuromasts in the zebrafish (Danio rerio) lateral line

    NARCIS (Netherlands)

    McHenry, Matthew J.; van Netten, Sietse M.

    2007-01-01

    Superficial neuromasts are structures that detect water flow on the surface of the body of fish and amphibians. As a component of the lateral line system, these receptors are distributed along the body, where they sense flow patterns that mediate a wide variety of behaviors. Their ability to detect

  12. Enhancement of thermoelectric figure-of-merit in laterally-coupled nanowire arrays

    International Nuclear Information System (INIS)

    Zhang, Yiqun; Shi, Yi; Pu, Lin; Wang, Junzhuan; Pan, Lijia; Zheng, Youdou

    2011-01-01

    A high ZT value is predicted in laterally-coupled nanowire arrays. The quantum confinement and coupling of electrons are considered in the framework of effective-mass envelope-function theory. The boundary scattering on phonons is also taken into account. The thermoelectric properties benefit from the large Seebeck coefficient and dramatically reduced lattice thermal conductivity, as well as the preserved electronic conductivity in the minibands of the coupling nanowires. The enhancement of ZT to more than 10-fold is achieved in the n-type Si nanowires/Ge host material. Results suggest that the laterally-coupled nanowire arrays can be designed for high-performance thermoelectric devices. -- Highlights: → A high ZT value is predicted in the lateral-coupling nanowire arrays. → The lattice thermal conductivity is dramatically reduced in the lateral direction of nanowire arrays. → The electron transport is preserved in the lateral direction due to the coupling effect. → The ZT value is largely enhanced as the nanowire volume fraction exceeds some critical point.

  13. Micro-Fluidic Device for Drug Delivery

    Science.gov (United States)

    Beebe, David J. (Inventor); MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Mensing, Glennys A. (Inventor)

    2014-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  14. Flow Diversion Panacea or Poison?

    Directory of Open Access Journals (Sweden)

    Mario eZanaty

    2014-02-01

    Full Text Available Endovascular therapy is now the treatment of choice for intracranial aneurysms (IAs for its efficacy and safety profile. the use of FD has recently expanded to cover many types of IAs in various locations. Some institutions even attempt FD as first line treatment for unruptured IAs. The most widely used devices are the Pipeline embolization device (PED, the SILK flow diverter (SFD, the flow redirection endoluminal device (FRED and Surpass. Many questions were raised regarding the long-term complications, the optimal regimen of dual antiplatelet therapy, and the durability of treatment effect. We reviewed the literature to address these questions as well as other concerns on FD when treating IAs.

  15. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  16. Device simulation and optimization of laterally-contacted-unipolar-nuclear detector

    CERN Document Server

    Lee, E Y

    1999-01-01

    Unipolar gamma-ray detectors offer the possibility of enhanced energy resolution and detection sensitivity over the conventional planar detectors. However, these detectors are difficult to understand and to fabricate, due to their three-dimensional geometry and multiple electrodes. Computer simulation offers a powerful way to design and to optimize these detectors, by giving the internal electric fields, weighting potentials, and spatially resolved detector responses. Simulation and optimization of an unipolar gamma-ray detector called laterally-contacted-unipolar-nuclear detector (LUND) are shown. For 662 keV gamma-rays from a sup 1 sup 3 sup 7 Cs source, the simulation and optimization of LUND resulted in improvement in the energy resolution from 1.6% to 1.3% and improvement in the active detector volume from 4% to 38% of the total detector volume.

  17. Eddy-current flow rate meter for measuring sodium flow rates

    International Nuclear Information System (INIS)

    Knaak, J.

    1976-01-01

    For safety reasons flow rate meters for monitoring coolant flow rates are inserted in the core of sodium-cooled fast breeder reactors. These are so-called eddy-current flow rate meters which can be mounted directly above the fuel elements. In the present contribution the principle of measurement, the mechanical construction and the circuit design of the flow rate measuring device are described. Special problems and their solution on developing the measuring system are pointed out. Finally, results of measurement and experience with the apparatus in several experiments are reported, where also further possibilities of application were tested. (orig./TK) [de

  18. Recharge and flow processes in a till aquitard

    DEFF Research Database (Denmark)

    Schrøder, Thomas Morville; Høgh Jensen, Karsten; Dahl, Mette

    1999-01-01

    Eastern Denmark is primarily covered by clay till. The transformation of the excess rainfall into laterally diverted groundwater flow, drain flow, stream flow, and recharge to the underlying aquifer is governed by complicatedinterrelated processes. Distributed hydrological models provide a framew......Eastern Denmark is primarily covered by clay till. The transformation of the excess rainfall into laterally diverted groundwater flow, drain flow, stream flow, and recharge to the underlying aquifer is governed by complicatedinterrelated processes. Distributed hydrological models provide...... a framework for assessing the individual flow components and forestablishing the overall water balance. Traditionally such models are calibrated against measurements of stream flow, head in the aquiferand perhaps drainage flow. The head in the near surface clay till deposits have generally not been measured...... the shallow wells and one in the valley adjacent to the stream. Precipitation and stream flow gauging along with potential evaporation estimates from a nearby weather station provide the basic data for the overall water balance assessment. The geological composition was determined from geoelectrical surveys...

  19. Simplified nonplanar wafer bonding for heterogeneous device integration

    Science.gov (United States)

    Geske, Jon; Bowers, John E.; Riley, Anton

    2004-07-01

    We demonstrate a simplified nonplanar wafer bonding technique for heterogeneous device integration. The improved technique can be used to laterally integrate dissimilar semiconductor device structures on a lattice-mismatched substrate. Using the technique, two different InP-based vertical-cavity surface-emitting laser active regions have been integrated onto GaAs without compromising the quality of the photoluminescence. Experimental and numerical simulation results are presented.

  20. Micromachined pressure/flow-sensor

    NARCIS (Netherlands)

    Oosterbroek, R.E.; Lammerink, Theodorus S.J.; Berenschot, Johan W.; Krijnen, Gijsbertus J.M.; Elwenspoek, Michael Curt; van den Berg, Albert

    1999-01-01

    The micromechanical equivalent of a differential pressure flow-sensor, well known in macro mechanics, is discussed. Two separate pressure sensors are used for the device, enabling to measure both, pressure as well as volume flow-rate. An integrated sensor with capacitive read-out as well as a

  1. Development of a fulcrum methodology to replicate the lateral ankle sprain mechanism and measure dynamic inversion speed.

    Science.gov (United States)

    Knight, Adam C; Weimar, Wendi H

    2012-09-01

    When the ankle is forced into inversion, the speed at which this movement occurs may affect the extent of injury. The purpose of this investigation was to develop a fulcrum device to mimic the mechanism of a lateral ankle sprain and to determine the reliability and validity of the temporal variables produced by this device. Additionally, this device was used to determine if a single previous lateral ankle sprain or ankle taping effected the time to maximum inversion and/or mean inversion speed. Twenty-six participants (13 with history of a single lateral ankle sprain and 13 with no history of injury) completed the testing. The participants completed testing on three separate days, performing 10 trials with the fulcrum per leg on each testing day, and tape was applied to both ankles on one testing day. No significant interactions or main effects were found for either previous injury or ankle taping, but good reliability was found for time to maximum inversion (ICC = .81) and mean inversion speed (ICC = .79). The findings suggest that although neither variable was influenced by the history of a single previous lateral ankle sprain or ankle taping, both variables demonstrated good reliability and construct validity, but not discriminative validity.

  2. Ramp Study Hemodynamics, Functional Capacity, and Outcome in Heart Failure Patients with Continuous-Flow Left Ventricular Assist Devices

    DEFF Research Database (Denmark)

    Jung, Mette H; Gustafsson, Finn; Houston, Brian

    2016-01-01

    Ramp studies-measuring changes in cardiac parameters as a function of serial pump speed changes (revolutions per minute [rpm])-are increasingly used to evaluate function and malfunction of continuous-flow left ventricular assist devices (CF-LVADs). We hypothesized that ramp studies can predict...... patients (HeartMate II, Thoratec Corporation, Pleasanton, CA). Functional status was evaluated in 70% (31/44); average 6 minute walk test (6MWT) was 312 ± 220 min, New York Heart Association (NYHA) I-II/III-IV (70/30%) and activity scores very low-low/moderate-very high (55/45%). Decrease in pulmonary...

  3. Device accurately measures and records low gas-flow rates

    Science.gov (United States)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  4. Ferrofluid-in-oil two-phase flow patterns in a flow-focusing microchannel

    Science.gov (United States)

    Sheu, T. S.; Chen, Y. T.; Lih, F. L.; Miao, J. M.

    This study investigates the two-phase flow formation process of water-based Fe3O4 ferrofluid (dispersed phase) in a silicon oil (continuous phase) flow in the microfluidic flow-focusing microchannel under various operational conditions. With transparent PDMS chip and optical microscope, four main two-phase flow patterns as droplet flow, slug flow, ring flow and churn flow are observed. The droplet shape, size, and formation mechanism were also investigated under different Ca numbers and intended to find out the empirical relations. The paper marks an original flow pattern map of the ferrofluid-in-oil flows in the microfluidic flow-focusing microchannels. The flow pattern transiting from droplet flow to slug flow appears for an operational conditions of QR < 1 and Lf / W < 1. The power law index that related Lf / W to QR was 0.36 in present device.

  5. Steam/water separation device for drying a wet vapour

    International Nuclear Information System (INIS)

    Sundheimer, P.

    1986-01-01

    The aim of the present invention is to dry a wet vapour which flows up to the device. The device has at least a group of steam dryer elements in a zone in which there is a vertical apertured panel; this vertical apertured panel is a metal grille with baffles the inlet steam flow to make it horizontal or slightly inclined to the bottom. The invention applies more particularly, to PWR steam generators [fr

  6. Highway-runoff quality, and treatment efficiencies of a hydrodynamic-settling device and a stormwater-filtration device in Milwaukee, Wisconsin

    Science.gov (United States)

    Horwatich, Judy A.; Bannerman, Roger T.; Pearson, Robert

    2011-01-01

    The treatment efficiencies of two prefabricated stormwater-treatment devices were tested at a freeway site in a high-density urban part of Milwaukee, Wisconsin. One treatment device is categorized as a hydrodynamic-settling device (HSD), which removes pollutants by sedimentation and flotation. The other treatment device is categorized as a stormwater-filtration device (SFD), which removes pollutants by filtration and sedimentation. During runoff events, flow measurements were recorded and water-quality samples were collected at the inlet and outlet of each device. Efficiency-ratio and summation-of-load (SOL) calculations were used to estimate the treatment efficiency of each device. Event-mean concentrations and loads that were decreased by passing through the HSD include total suspended solids (TSS), suspended sediment (SS), total phosphorus (TP), total copper (TCu), and total zinc (TZn). The efficiency ratios for these constituents were 42, 57, 17, 33, and 23 percent, respectively. The SOL removal rates for these constituents were 25, 49, 10, 27, and 16 percent, respectively. Event-mean concentrations and loads that increased by passing through the HSD include chloride (Cl), total dissolved solids (TDS), and dissolved zinc (DZn). The efficiency ratios for these constituents were -347, -177, and 20 percent, respectively. Four constituents—dissolved phosphorus (DP), chemical oxygen demand (COD), total polycyclic aromatic hydrocarbon (PAH), and dissolved copper (DCu)—are not included in the list of computed efficiency ratio and SOL because the variability between sampled inlet and outlet pairs were not significantly different. Event-mean concentrations and loads that decreased by passing through the SFD include TSS, SS, TP, DCu, TCu, DZn, TZn, and COD. The efficiency ratios for these constituents were 59, 90, 40, 21, 66, 23, 66, and 18, respectively. The SOLs for these constituents were 50, 89, 37, 19, 60, 20, 65, and 21, respectively. Two constituents—DP and

  7. Memory attacks on device-independent quantum cryptography.

    Science.gov (United States)

    Barrett, Jonathan; Colbeck, Roger; Kent, Adrian

    2013-01-04

    Device-independent quantum cryptographic schemes aim to guarantee security to users based only on the output statistics of any components used, and without the need to verify their internal functionality. Since this would protect users against untrustworthy or incompetent manufacturers, sabotage, or device degradation, this idea has excited much interest, and many device-independent schemes have been proposed. Here we identify a critical weakness of device-independent protocols that rely on public communication between secure laboratories. Untrusted devices may record their inputs and outputs and reveal information about them via publicly discussed outputs during later runs. Reusing devices thus compromises the security of a protocol and risks leaking secret data. Possible defenses include securely destroying or isolating used devices. However, these are costly and often impractical. We propose other more practical partial defenses as well as a new protocol structure for device-independent quantum key distribution that aims to achieve composable security in the case of two parties using a small number of devices to repeatedly share keys with each other (and no other party).

  8. SiC Discrete Power Devices

    National Research Council Canada - National Science Library

    Baliga, B

    2000-01-01

    .... The investigation of the poor performance of the 4H-SiC ACCUFETs provided insights for changes in device design and process flow, for improving their breakdown voltage and specific on-resistance...

  9. Influence of slip-surface geometry on earth-flow deformation, Montaguto earth flow, southern Italy

    Science.gov (United States)

    Guerriero, L.; Coe, Jeffrey A.; Revellio, P.; Grelle, G.; Pinto, F.; Guadagno, F.

    2016-01-01

    We investigated relations between slip-surface geometry and deformational structures and hydrologic features at the Montaguto earth flow in southern Italy between 1954 and 2010. We used 25 boreholes, 15 static cone-penetration tests, and 22 shallow-seismic profiles to define the geometry of basal- and lateral-slip surfaces; and 9 multitemporal maps to quantify the spatial and temporal distribution of normal faults, thrust faults, back-tilted surfaces, strike-slip faults, flank ridges, folds, ponds, and springs. We infer that the slip surface is a repeating series of steeply sloping surfaces (risers) and gently sloping surfaces (treads). Stretching of earth-flow material created normal faults at risers, and shortening of earth-flow material created thrust faults, back-tilted surfaces, and ponds at treads. Individual pairs of risers and treads formed quasi-discrete kinematic zones within the earth flow that operated in unison to transmit pulses of sediment along the length of the flow. The locations of strike-slip faults, flank ridges, and folds were not controlled by basal-slip surface topography but were instead dependent on earth-flow volume and lateral changes in the direction of the earth-flow travel path. The earth-flow travel path was strongly influenced by inactive earth-flow deposits and pre-earth-flow drainages whose positions were determined by tectonic structures. The implications of our results that may be applicable to other earth flows are that structures with strikes normal to the direction of earth-flow motion (e.g., normal faults and thrust faults) can be used as a guide to the geometry of basal-slip surfaces, but that depths to the slip surface (i.e., the thickness of an earth flow) will vary as sediment pulses are transmitted through a flow.

  10. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  11. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Science.gov (United States)

    2010-04-01

    ... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion...

  12. High-speed carrier-depletion silicon Mach-Zehnder optical modulators with lateral PN junctions

    Directory of Open Access Journals (Sweden)

    Graham Trevor Reed

    2014-12-01

    Full Text Available This paper presents new experimental data from a lateral PN junction silicon Mach-Zehnder optical modulator. Efficiencies in the 1.4V.cm to 1.9V.cm range are demonstrated for drive voltages between 0V and 6V. High speed operation up to 52Gbit/s is also presented. The performance of the device which has its PN junction positioned in the centre of the waveguide is then compared to previously reported data from a lateral PN junction device with the junction self-aligned to the edge of the waveguide rib. An improvement in modulation efficiency is demonstrated when the junction is positioned in the centre of the waveguide. Finally we propose schemes for achieving high modulation efficiency whilst retaining self-aligned formation of the PN junction.

  13. Lateral migration of a microdroplet under optical forces in a uniform flow

    International Nuclear Information System (INIS)

    Cho, Hyunjun; Chang, Cheong Bong; Jung, Jin Ho; Sung, Hyung Jin

    2014-01-01

    The behavior of a microdroplet in a uniform flow and subjected to a vertical optical force applied by a loosely focused Gaussian laser beam was studied numerically. The lattice Boltzmann method was applied to obtain the two-phase flow field, and the dynamic ray tracing method was adopted to calculate the optical force. The optical forces acting on the spherical droplets agreed well with the analytical values. The numerically predicted droplet migration distances agreed well with the experimentally obtained values. Simulations of the various flow and optical parameters showed that the droplet migration distance nondimensionalized by the droplet radius is proportional to the S number (z d /r p = 0.377S), which is the ratio of the optical force to the viscous drag. The effect of the surface tension was also examined. These results indicated that the surface tension influenced the droplet migration distance to a lesser degree than the flow and optical parameters. The results of the present work hold for the refractive indices of the mean fluid and the droplet being 1.33 and 1.59, respectively

  14. Stress Analysis of Fuel Rod under Axial Coolant Flow

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hai Lan; Lee, Young Shin; Lee, Hyun Seung [Chungnam National University, Daejeon (Korea, Republic of); Park, Num Kyu; Jeon, Kyung Rok [Kerea Nuclear Fuel., Daejeon (Korea, Republic of)

    2010-05-15

    A pressurized water reactor(PWR) fuel assembly, is a typical bundle structure, which uses light water as a coolant in most commercial nuclear power plants. Fuel rods that have a very slender and long clad are supported by fuel assembly which consists of several spacer grids. A coolant is a fluid which flows through device to prevent its overheating, transferring the heat produced by the device to other devices that use or dissipate it. But at the same time, the coolant flow will bring out the fluid induced vibration(FIV) of fuel rods and even damaged the fuel rod. This study has been conducted to investigate the flow characteristics and nuclear reactor fuel rod stress under effect of coolant. Fluid structure interaction(FSI) analysis on nuclear reactor fuel rod was performed. Fluid analysis of the coolant which flow along the axial direction and structural analysis under effect of flow velocity were carried out under different output flow velocity conditions

  15. Stress Analysis of Fuel Rod under Axial Coolant Flow

    International Nuclear Information System (INIS)

    Jin, Hai Lan; Lee, Young Shin; Lee, Hyun Seung; Park, Num Kyu; Jeon, Kyung Rok

    2010-01-01

    A pressurized water reactor(PWR) fuel assembly, is a typical bundle structure, which uses light water as a coolant in most commercial nuclear power plants. Fuel rods that have a very slender and long clad are supported by fuel assembly which consists of several spacer grids. A coolant is a fluid which flows through device to prevent its overheating, transferring the heat produced by the device to other devices that use or dissipate it. But at the same time, the coolant flow will bring out the fluid induced vibration(FIV) of fuel rods and even damaged the fuel rod. This study has been conducted to investigate the flow characteristics and nuclear reactor fuel rod stress under effect of coolant. Fluid structure interaction(FSI) analysis on nuclear reactor fuel rod was performed. Fluid analysis of the coolant which flow along the axial direction and structural analysis under effect of flow velocity were carried out under different output flow velocity conditions

  16. Advanced 65 nm CMOS devices fabricated using ultra-low energy plasma doping

    International Nuclear Information System (INIS)

    Walther, S.; Lenoble, D.; Lallement, F.; Grouillet, A.; Erokhin, Y.; Singh, V.; Testoni, A.

    2005-01-01

    For leading edge CMOS and DRAM technologies, plasma doping (PLAD) offers several unique advantages over conventional beamline implantation. For ultra-low energy source and drain extensions (SDE), source drain contact and high dose poly doping implants PLAD delivers 2-5x higher throughput compared to beamline implanters. In this work we demonstrate process performance and process integration benefits enabled by plasma doping for advanced 65 nm CMOS devices. Specifically, p + /n ultra-shallow junctions formed with BF 3 plasma doping have superior X j /R s characteristics to beamline implants and yield up to 30% lower R s for 20 nm X j while using standard spike anneal with ramp-up rate of 75 deg. C/s. These results indicate that PLAD could extend applicability of standard spike anneal by at least one technology node past 65 nm. A CMOS split lot has been run to investigate process integration advantages unique to plasma doping and to determine CMOS device characteristics. Device data measured on 65 nm transistors fabricated with offset spacers indicate that devices with SDE formed by plasma doping have superior V t roll-off characteristics arguably due to improved lateral gate-overlap of PLAD SDE junctions. Furthermore, offset spacers could be eliminated in 65 nm devices with PLAD SDE implants while still achieving V t roll-off and I on -I off performance at least equivalent to control devices with offset spacers and SDE formed by beamline implantation. Thus, another advantage of PLAD is simplified 65 nm CMOS manufacturing process flow due to elimination of offset spacers. Finally, we present process transfer from beamline implants to PLAD for several applications, including SDE and gate poly doping with very high productivity

  17. Evaluation of Hanau's formula in determination of lateral condylar guidance: A clinical research study

    Science.gov (United States)

    Bhawsar, Sanjay Vasant; Marathe, Ashlesha Subhash; Ansari, Sadekh Abdul

    2015-01-01

    Statement of Problem: The accuracy and reliability of the methods used for programming the semi-adjustable articulators determine the accuracy in occlusion. The current recommended average settings using the Hanau's formula commonly used by clinicians is questionable, and thus reassessment is needed. This study was carried out to evaluate and compare the lateral condylar guidance: (1) Using the Hanau's formula and the computerized jaw tracking device (Kinesiograph). (2) On the right and left sides using both these methods. Materials and Methods: A total of 20 completely edentulous patients (14 male and 6 females) within 40–60 years of age were selected. Jaw relation was recorded followed by face bow transfer. Extraoral Gothic arch tracing was recorded; three protrusive records were obtained and condylar guidance was calculated. Lateral condylar guidance was then calculated using Hanau's formula, followed by the computerized jaw tracking device. A comparative evaluation was done of the obtained values. The same investigator worked with each of the study participants for the purpose of standardization. Results: The lateral condylar guidance values obtained using the Hanau's formula ranged from 14 to 17° while those obtained using the computerized K7 jaw tracking device ranged from 8 to 40°. Bennett angle values, obtained using the jaw tracking device and Hanau's formula showed statistically significant differences (P 0.05). Conclusion: Based on the results, dentist and dental technicians should consider reassessing the current recommended average settings and use of the Hanau's formula for programming the semi-adjustable articulators. PMID:26929535

  18. Continuous flow left ventricular assist devices: shared care goals of monitoring and treating patients.

    Science.gov (United States)

    Estep, Jerry D; Trachtenberg, Barry H; Loza, Laurie P; Bruckner, Brian A

    2015-01-01

    Continuous-flow left ventricular assist devices (CF-LVADs) have been clinically adopted as a long-term standard of care therapy option for patients with end-stage heart failure. For many patients, shared care between the care providers at the implanting center and care providers in the community in which the patient resides is a clinical necessity. The aims of this review are to (1) provide a rationale for the outpatient follow-up exam and surveillance testing used at our center to monitor patients supported by the HeartMate II(®) CF-LVAD (Thoratec Corporation, Pleasanton, CA) and (2) provide the protocol/algorithms we use for blood pressure, driveline exit site, LVAD alarm history, surveillance blood work, and echocardiography monitoring in this patient population. In addition, we define our partnership outpatient follow-up protocol and the "shared care" specific responsibilities we use with referring health care providers to best manage many of our patients.

  19. Fabrication of quantum-dot devices in graphene

    Directory of Open Access Journals (Sweden)

    Satoshi Moriyama, Yoshifumi Morita, Eiichiro Watanabe, Daiju Tsuya, Shinya Uji, Maki Shimizu and Koji Ishibashi

    2010-01-01

    Full Text Available We describe our recent experimental results on the fabrication of quantum-dot devices in a graphene-based two-dimensional system. Graphene samples were prepared by micromechanical cleavage of graphite crystals on a SiO2/Si substrate. We performed micro-Raman spectroscopy measurements to determine the number of layers of graphene flakes during the device fabrication process. By applying a nanofabrication process to the identified graphene flakes, we prepared a double-quantum-dot device structure comprising two lateral quantum dots coupled in series. Measurements of low-temperature electrical transport show the device to be a series-coupled double-dot system with varied interdot tunnel coupling, the strength of which changes continuously and non-monotonically as a function of gate voltage.

  20. Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array.

    Science.gov (United States)

    Payne, A; Merrill, R; Minalga, E; Vyas, U; de Bever, J; Todd, N; Hadley, R; Dumont, E; Neumayer, L; Christensen, D; Roemer, R; Parker, D

    2012-03-01

    This work presents the design and preliminary evaluation of a new laterally mounted phased-array MRI-guided high-intensity focused ultrasound (MRgHIFU) system with an integrated 11-channel phased-array radio frequency (RF) coil intended for breast cancer treatment. The design goals for the system included the ability to treat the majority of tumor locations, to increase the MR image's signal-to-noise ratio (SNR) throughout the treatment volume and to provide adequate comfort for the patient. In order to treat the majority of the breast volume, the device was designed such that the treated breast is suspended in a 17-cm diameter treatment cylinder. A laterally shooting 1-MHz, 256-element phased-array ultrasound transducer with flexible positioning is mounted outside the treatment cylinder. This configuration achieves a reduced water volume to minimize RF coil loading effects, to position the coils closer to the breast for increased signal sensitivity, and to reduce the MR image noise associated with using water as the coupling fluid. This design uses an 11-channel phased-array RF coil that is placed on the outer surface of the cylinder surrounding the breast. Mechanical positioning of the transducer and electronic steering of the focal spot enable placement of the ultrasound focus at arbitrary locations throughout the suspended breast. The treatment platform allows the patient to lie prone in a face-down position. The system was tested for comfort with 18 normal volunteers and SNR capabilities in one normal volunteer and for heating accuracy and stability in homogeneous phantom and inhomogeneous ex vivo porcine tissue. There was a 61% increase in mean relative SNR achieved in a homogeneous phantom using the 11-channel RF coil when compared to using only a single-loop coil around the chest wall. The repeatability of the system's energy delivery in a single location was excellent, with less than 3% variability between repeated temperature measurements at the same