WorldWideScience

Sample records for laser-based indirect fluorometric

  1. Indirect fluorometric detection techniques on thin layer chromatography and effect of ultrasound on gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Yinfa, Ma.

    1990-12-10

    Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will be described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.

  2. The fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Lindhagen, Elin; Nygren, Peter; Larsson, Rolf

    2008-01-01

    The fluorometric microculture cytotoxicity assay (FMCA) is a nonclonogenic microplate-based cell viability assay used for measurement of the cytotoxic and/or cytostatic effect of different compounds in vitro. The assay is based on hydrolysis of the probe, fluorescein diacetate (FDA) by esterases in cells with intact plasma membranes. The assay is available as both a semiautomated 96-well plate setup and a 384-well plate version fully adaptable to robotics. Experimental plates are prepared with a small amount of drug solution and can be stored frozen. Cells are seeded on the plates and cell viability is evaluated after 72 h. The protocol described here is applicable both for cell lines and freshly prepared tumor cells from patients and is suitable both for screening in drug development and as a basis for a predictive test for individualization of anticancer drug therapy.

  3. Microsomal aryl hydrocarbon hydroxylase comparison of the direct, indirect and radiometric assays

    International Nuclear Information System (INIS)

    Denison, M.S.; Murray, M.; Wilkinson, C.F.

    1983-01-01

    The direct fluorometric assay of aryl hydrocarbon hydroxlyase has been compared to the more commonly used indirect fluorometric and radiometric assays. Although rat hepatic microsomal activities measured by the direct assay were consistently higher than those obtained by the other assays, the relative changes in activity following enzyme induction and/or inhibition were similar. The direct assay provides an accurate and rapid measure of aryl hydrocarbon hydroxylase activity and avoids several problems inherent in the indirect and radiometric assays. 2 tables

  4. Fluorometric determination of nitrite with 4-hydroxycoumarin

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, T.; Arai, Y.; Takitani, S.

    1986-12-01

    A simple, sensitive, and reproducible fluorometric method for determination of nitrite has been developed. This method is based on the nitrosation of 4-hydroxycoumarin in acidic medium and subsequent reduction to 3-amino-4-hydroxy-coumarin, which is fluorescent in alkaline medium. The fluorescence intensity is proportional to the nitrite concentration in the range of 3 ng/mL to 1 ..mu..g/mL in the sample solution, with a relative standard deviation of 0.5% (50 ng/mL). The method has been applied to the determination of nitrite in saliva.

  5. Determination of lithium in rocks: Fluorometric method

    Science.gov (United States)

    White, C.E.; Fletcher, M.H.; Parks, J.

    1951-01-01

    The gravimetric method in general use for the determination of lithium is tedious, and the final weighed product often contains other alkali metals. A fluorometric method was developed to shorten the time required for the analysis and to assure that the final determination is for lithium alone. This procedure is based on the complex formed between lithium and 8-hydroxyquinoline. The fluorescence is developed in a slightly alkaline solution of 95% alcohol and measurement is made on a photoelectric fluorometer. Separation from the ore is carried out by the wet method or by the distillation procedure. Sodium and potassium are removed by alcohol and ether, but complete separation is not necessary. Comparison of analyzed samples shows excellent agreement with spectrographic and gravimetric methods. The fluorometric method is more rapid than the gravimetric and produces more conclusive results. Another useful application is in the preparation of standard lithium solutions from reagent quality salts when a known standard is available. In this case no separations are necessary.

  6. Fluorometric analysis for uranium in natural waters

    International Nuclear Information System (INIS)

    Waterbury, G.R.

    1977-01-01

    A fluorometric method is used for the routine determination of uranium at 0.2 to parts-per-billion (ppB) concentrations in natural surface waters. Duplicate 200-μl aliquots of the water samples are pipetted onto 0.4-g pellets of 98 percent NaF-2 percent LiF flux contained in platinum dishes. The pellets are dried under heat lamps and fused over special propane burners. The fused pellets are subjected to ultraviolet radiation and the fluorescence is measured in a fluorometer. The lower limit of detection is 0.2 ppB of uranium, and the precision is about 15 relative percent in the 0.2 to 10 ppB uranium concentration range. Two analysts determine uranium in 750 to 900 samples per week using this method. Samples containing solids or more than 19 ppB of uranium are analyzed by a delayed neutron counting method

  7. Fluorometric determination of zirconium in minerals

    Science.gov (United States)

    Alford, W.C.; Shapiro, L.; White, C.E.

    1951-01-01

    The increasing use of zirconium in alloys and in the ceramics industry has created renewed interest in methods for its determination. It is a common constituent of many minerals, but is usually present in very small amounts. Published methods tend to be tedious, time-consuming, and uncertain as to accuracy. A new fluorometric procedure, which overcomes these objections to a large extent, is based on the blue fluorescence given by zirconium and flavonol in sulfuric acid solution. Hafnium is the only element that interferes. The sample is fused with borax glass and sodium carbonate and extracted with water. The residue is dissolved in sulfuric acid, made alkaline with sodium hydroxide to separate aluminum, and filtered. The precipitate is dissolved in sulfuric acid and electrolysed in a Melaven cell to remove iron. Flavonol is then added and the fluorescence intensity is measured with a photo-fluorometer. Analysis of seven standard mineral samples shows excellent results. The method is especially useful for minerals containing less than 0.25% zirconium oxide.

  8. Fluorometric determination of histamine in cheese.

    Science.gov (United States)

    Chambers, T L; Staruszkiewicz, W F

    1978-09-01

    Thirty-one samples of cheese obtained from retail outlets were analyzed for histamine, using an official AOAC fluorometric method. The types of cheese analyzed and the ranges of histamine found were: colby, 0.3--2.8; camembert, 0.4--4.2; cheddar, 1.2--5.8; gouda, 1.3--2.4; provolone, 2.0--23.5; roquefort, 1.0--16.8; mozzarella 1.6--5.0; and swiss, 0.4--250 mg histamine/100 g. Ten of the 12 samples of swiss cheese contained less than 16 mg histamine/100 g. The remaining 2 samples which contained 116 and 250 mg histamine/100 g were judged organoleptically to be of poor quality. An investigation of one processing facility showed that the production of histamine in swiss cheese may have been a result of a hydrogen peroxide/low temperature treatment of the milk supply. Recovery of histamine added to methanol extracts of cheese ranged from 93 to 105%. Histamine content was confirmed by high pressure liquid chromatographic analysis of the methanol extracts.

  9. Fluorometric determination of uric acid in bovine milk

    DEFF Research Database (Denmark)

    Larsen, Torben; Moyes, Kasey

    2010-01-01

    The primary objective of this study is to validate a new fast method for determination of uric acid in milk. The method is based on an enzymatic-fluorometric technique that requires minimal pre-treatment of milk samples. The present determination of uric acid is based on the enzymatic oxidation o...

  10. Fluorometric Assessment Of Lysosomal Enzymes In Garlic Oil ...

    African Journals Online (AJOL)

    The effect of Garlic oil on Lysosomal enzymes in streptozotocin-induced diabetic rats were investigated fluorometrically. The serum lysosomal enzymes assayed include β-glucuronidase, N-acetylglucosaminidase (NAG) β-D-galactosidase and α-D-galactosidase. The results of the study in nMole-4Mu/hr/ml show that ...

  11. Laser-based additive manufacturing of metals

    CSIR Research Space (South Africa)

    Kumar, S

    2010-11-01

    Full Text Available For making metallic products through Additive Manufacturing (AM) processes, laser-based systems play very significant roles. Laser-based processes such as Selective Laser Melting (SLM) and Laser Engineered Net Shaping (LENS) are dominating processes...

  12. Enzymatic-fluorometric quantification of cholesterol in bovine milk

    DEFF Research Database (Denmark)

    Larsen, Torben

    2012-01-01

    The present paper describes an enzymatic–fluorometric method for the determination of cholesterol in milk and other opaque matrices. The initial step of the method is to liberate chemically and physically bound cholesterol from the milk fat globule membrane by enzymatic action. The method is able...... to discriminate between esterified and free cholesterol in milk. The analysis is cost effective and is developed to work directly on whole, fresh milk thereby eliminating time consuming and tedious pre-treatment procedures of the sample. More than 1000 milk samples were analysed on the day of sampling. The total...... concentration of milk cholesterol ranged from 80 to 756 μM (n = 1068; mean 351 μM). Milk cholesterol was significantly correlated to milk fat concentration as analysed by mid-infra red spectrometry (r = 0.630; n = 853) and by an enzymatic–fluorometric method (triacylglycerol) (r = 0.611; n = 842)....

  13. Modern Aspects Of Fluorometric Detection In Liquid-Phase Chromatography

    Science.gov (United States)

    Bousquet, Bernard; Garnier, Jean P.; Dreux, Claude

    1983-10-01

    Recent advances are described in the combined use of fluorometric derivatization and high performance liquid chromatography (HPLC) for clinical chemistry determinations. Derivatives (especially dansyl derivatives) can be formed prior to chromatography in the case of estrogens, amino acids, and catecholamines. In post-column reactions, we preferred to use air-segmented reactions as they conform better to all the optimized chromatographic and spectrofluorometric parameters. Fluorescent derivatives produced from cate-cholamines, tryptophan and its metabolites, hydroxyindoles, tryptamine, amino acids, sugars, polyamines, and other substances are often sufficiently sensitive to be detected in picogram quantities by HPLC. Their reaction principle and some of their applications to samples are described. Recently, chemical excitation of fluorophore-like dansyl amino acid was proposed as a detection system for HPLC. By a post-column reaction, a fluorophore can be made to emit light by its reaction with trichlorophenyl oxalate (TCPO) and hydrogen peroxide. The detection limit of this system is about 10 fmol for each dansyl amino acid. Application of this new reaction to catecholamines opens up new prospects for fluorometric detection.

  14. Laser-based optical detection of explosives

    CERN Document Server

    Pellegrino, Paul M; Farrell, Mikella E

    2015-01-01

    Laser-Based Optical Detection of Explosives offers a comprehensive review of past, present, and emerging laser-based methods for the detection of a variety of explosives. This book: Considers laser propagation safety and explains standard test material preparation for standoff optical-based detection system evaluation Explores explosives detection using deep ultraviolet native fluorescence, Raman spectroscopy, laser-induced breakdown spectroscopy, reflectometry, and hyperspectral imaging Examines photodissociation followed by laser-induced fluorescence, photothermal methods, cavity-enhanced absorption spectrometry, and short-pulse laser-based techniques Describes the detection and recognition of explosives using terahertz-frequency spectroscopic techniques Each chapter is authored by a leading expert on the respective technology, and is structured to supply historical perspective, address current advantages and challenges, and discuss novel research and applications. Readers are left with an in-depth understa...

  15. Fluorometric determination of ethidium bromide efflux kinetics in Escherichia coli

    Directory of Open Access Journals (Sweden)

    Monteiro Gabriel A

    2009-10-01

    Full Text Available Abstract Background Efflux pump activity has been associated with multidrug resistance phenotypes in bacteria, compromising the effectiveness of antimicrobial therapy. The development of methods for the early detection and quantification of drug transport across the bacterial cell wall is a tool essential to understand and overcome this type of drug resistance mechanism. This approach was developed to study the transport of the efflux pump substrate ethidium bromide (EtBr across the cell envelope of Escherichia coli K-12 and derivatives, differing in the expression of their efflux systems. Results EtBr transport across the cell envelope of E. coli K-12 and derivatives was analysed by a semi-automated fluorometric method. Accumulation and efflux of EtBr was studied under limiting energy supply (absence of glucose and low temperature and in the presence and absence of the efflux pump inhibitor, chlorpromazine. The bulk fluorescence variations were also observed by single-cell flow cytometry analysis, revealing that once inside the cells, leakage of EtBr does not occur and that efflux is mediated by active transport. The importance of AcrAB-TolC, the main efflux system of E. coli, in the extrusion of EtBr was evidenced by comparing strains with different levels of AcrAB expression. An experimental model was developed to describe the transport kinetics in the three strains. The model integrates passive entry (influx and active efflux of EtBr, and discriminates different degrees of efflux between the studied strains that vary in the activity of their efflux systems, as evident from the calculated efflux rates: = 0.0173 ± 0.0057 min-1; = 0.0106 ± 0.0033 min-1; and = 0.0230 ± 0.0075 min-1. Conclusion The combined use of a semi-automated fluorometric method and an experimental model allowed quantifying EtBr transport in E. coli strains that differ in their overall efflux activity. This methodology can be used for the early detection of differences in

  16. A facile molecularly imprinted polymer-based fluorometric assay for detection of histamine

    DEFF Research Database (Denmark)

    Feng, Xiaotong; Ashley, Jon; Zhou, Tongchang

    2018-01-01

    urgently needed. In this paper, we developed a facile and cost-effective molecularly imprinted polymer (MIP)-based fluorometric assay to directly quantify histamine. Histamine-specific MIP nanoparticles (nanoMIPs) were synthesized using a modified solid-phase synthesis method. They were then immobilized...

  17. Commercialization plan laser-based decoating systems

    International Nuclear Information System (INIS)

    Freiwald, J.; Freiwald, D.A.

    1998-01-01

    F2 Associates Inc. (F2) is a small, high-technology firm focused on developing and commercializing environmentally friendly laser ablation systems for industrial-rate removal of surface coatings from metals, concrete, and delicate substrates such as composites. F2 has a contract with the US Department of Energy Federal Energy Technology Center (FETC) to develop and test a laser-based technology for removing contaminated paint and other contaminants from concrete and metal surfaces. Task 4.1 in Phase 2 of the Statement of Work for this DOE contract requires that F2 ''document its plans for commercializing and marketing the stationary laser ablation system. This document shall include a discussion of prospects for commercial customers and partners and may require periodic update to reflect changing strategy. This document shall be submitted to the DOE for review.'' This report is being prepared and submitted in fulfillment of that requirement. This report describes the laser-based technology for cleaning and coatings removal, the types of laser-based systems that have been developed by F2 based on this technology, and the various markets that are emerging for this technology. F2's commercialization and marketing plans are described, including how F2's organization is structured to meet the needs of technology commercialization, F2's strategy and marketing approach, and the necessary steps to receive certification for removing paint from aircraft and DOE certification for D and D applications. The future use of the equipment built for the DOE contract is also discussed

  18. LIGHT: Towards a laser-based accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Busold, Simon; Deppert, Oliver; Roth, Markus [Technical University of Darmstadt, Institute for Nuclear Physics, Schlossgartenstrasse 9, 64289 Darmstadt (Germany); Brabetz, Christian [Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany); Burris-Mog, Trevor; Joost, Martin; Cowan, Tom [Helmholtz Center Dresden-Rossendorf, Bautzner Landstrasse 400, 01328 Dresden (Germany); Blazevic, Abel; Bagnoud, Vincent [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Zielbauer, Bernhard [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Helmholtz Institute Jena, Helmholtzweg 4, 07743 Jena (Germany); Kester, Oliver [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany)

    2012-07-01

    Proton acceleration by ultrashort, high intensity laser pulses has been a fast growing field of research during the last decade. The most intensely investigated acceleration mechanism is the TNSA mechanism (Target Normal Sheath Acceleration), providing protons in the multi-MeV-range. For many possible applications, however, the full energy spread and large beam divergence are major draw-backs. Therefore, a pulsed high-field solenoid was used for collimation and energy-selection and is now integrated in a full test stand for a laser-based accelerator at GSI Helmholtz Center, Darmstadt, namely the LIGHT project (Laser Ion Generation, Handling and Transport), which is a collaboration between TU Darmstadt, GSI, HZDR, JWGU Frankfurt and HI Jena. An overview of the new infrastructure, the goals of the LIGHT project, and first experimental results are presented.

  19. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  20. Fluorometric detection of adenine in target DNA by exciplex formation with fluorescent 8-arylethynylated deoxyguanosine.

    Science.gov (United States)

    Saito, Yoshio; Kugenuma, Kenji; Tanaka, Makiko; Suzuki, Azusa; Saito, Isao

    2012-06-01

    We demonstrated an intriguing method to discriminate adenine by incident appearance of an intense new emission via exciplex formation in hybridization of target DNA with newly designed fluorescent 8-arylethynylated deoxyguanosine derivatives. We described the synthesis of such highly electron donating fluorescent guanosine derivatives and their incorporation into DNA oligomers which may be used for the structural study and the fluorometric analysis of nucleic acids. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Dynamic modification of microorganisms by pyrenebutanoate for fluorometric detection in capillary zone electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Horká, Marie; Růžička, F.; Holá, V.; Šlais, Karel

    2005-01-01

    Roč. 26, č. 3 (2005), s. 548-555 ISSN 0173-0835 R&D Projects: GA AV ČR(CZ) IBS4031201; GA ČR(CZ) GA203/02/1447; GA AV ČR(CZ) IAA4031302 Institutional research plan: CEZ:AV0Z40310501 Keywords : CZE * microorganisms * fluorometric detection Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.850, year: 2005

  2. Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants

    OpenAIRE

    Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki

    2015-01-01

    Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates f...

  3. Methodology for assessing laser-based equipment

    Science.gov (United States)

    Pelegrina-Bonilla, Gabriel; Hermsdorf, Jörg; Thombansen, Ulrich; Abels, Peter; Kaierle, Stefan; Neumann, Jörg

    2017-10-01

    Methodologies for the assessment of technology's maturity are widely used in industry and research. Probably the best known are technology readiness levels (TRLs), initially pioneered by the National Aeronautics and Space Administration (NASA). At the beginning, only descriptively defined TRLs existed, but over time, automated assessment techniques in the form of questionnaires emerged in order to determine TRLs. Originally TRLs targeted equipment for space applications, but the demands on industrial relevant equipment are partly different in terms of, for example, overall costs, product quantities, or the presence of competitors. Therefore, we present a commonly valid assessment methodology with the aim of assessing laser-based equipment for industrial use, in general. The assessment is carried out with the help of a questionnaire, which allows for a user-friendly and easy accessible way to monitor the progress from the lab-proven state to the application-ready product throughout the complete development period. The assessment result is presented in a multidimensional metric in order to reveal the current specific strengths and weaknesses of the equipment development process, which can be used to direct the remaining development process of the equipment in the right direction.

  4. Laser-based measuring equipment controlled by microcomputer

    International Nuclear Information System (INIS)

    Miron, N.; Sporea, D.; Velculescu, V.G.; Petre, M.

    1988-03-01

    Some laser-based measuring equipment controlled by microcomputer developed for industrial and scientific purposes are described. These equipments are intended for dial indicators verification, graduated rules measurement, and for very accurate measurement of the gravitational constant. (authors)

  5. Ineffectiveness of a fluorometric method for identifying irradiated food base on thymine glycol

    International Nuclear Information System (INIS)

    Ewing, D.D.; Stepanik, T.M.

    1992-01-01

    At dosages used for food irradiation, some of the thymine present in the DNA of irradiated food may be converted to thymine glycol. A fluorometric assay for thymine glycol was investigated as a possible method of detecting irradiated foods based on this effect. Experiments were performed on homogenates of irradiated chicken breast meat and on DNA isolated from irradiated chicken breast meat. In both cases the assay was subject to interference from one of the reagents, o-aminobenzaldehyde, and lacked the necessary sensitivity to detect the thymine glycol produced by radiolysis of the DNA at relevant dosages

  6. Fluorometric method for the determination of gas-phase hydrogen peroxide

    Science.gov (United States)

    Kok, Gregory L.; Lazrus, Allan L.

    1986-01-01

    The fluorometric gas-phase hydrogen peroxide procedure is based on the technique used by Lazrus et. al. for the determination of H2O2 in the liquid phase. The analytical method utilizes the reaction of H2O2 with horseradish peroxidase and p-hydroxphenylacetic acid (POPHA) to form the fluorescent dimer of POPHA. The analytical reaction responds stoichiometrically to both H2O2 and some organic hydroperoxides. To discriminate H2O2 from organic hydroperoxides, catalase is used to preferentially destroy H2O2. Using a dual-channel flow system the H2O2 concentration is determined by difference.

  7. A high throughput biochemical fluorometric method for measuring lipid peroxidation in HDL.

    Directory of Open Access Journals (Sweden)

    Theodoros Kelesidis

    Full Text Available Current cell-based assays for determining the functional properties of high-density lipoproteins (HDL have limitations. We report here the development of a new, robust fluorometric cell-free biochemical assay that measures HDL lipid peroxidation (HDLox based on the oxidation of the fluorochrome Amplex Red. HDLox correlated with previously validated cell-based (r = 0.47, p<0.001 and cell-free assays (r = 0.46, p<0.001. HDLox distinguished dysfunctional HDL in established animal models of atherosclerosis and Human Immunodeficiency Virus (HIV patients. Using an immunoaffinity method for capturing HDL, we demonstrate the utility of this novel assay for measuring HDLox in a high throughput format. Furthermore, HDLox correlated significantly with measures of cardiovascular diseases including carotid intima media thickness (r = 0.35, p<0.01 and subendocardial viability ratio (r = -0.21, p = 0.05 and physiological parameters such as metabolic and anthropometric parameters (p<0.05. In conclusion, we report the development of a new fluorometric method that offers a reproducible and rapid means for determining HDL function/quality that is suitable for high throughput implementation.

  8. Fluorometric sensing of Triton X-100 based organized media in water by a MOF

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Biswajit, E-mail: bdeychem@gmail.com [Department of Chemistry, Visva-Bharati University, Santiniketan 731235 (India); Mondal, Ranjan Kumar; Dhibar, Subhendu [Department of Chemistry, Visva-Bharati University, Santiniketan 731235 (India); Chattopadhyay, Asoke Prasun [Department of Chemistry, University of Kalyani, Kalyani 741235 (India); Bhattacharya, Subhash Chandra [Department of Chemistry, Jadavpur University, Kolkata 700032 (India)

    2016-04-15

    The fluorescent property of the aqueous solution of a metal organic framework (MOF) of Mn(II), having a sedimentary rocks like microstructure in solid-state, has been investigated. The luminescent feature of the the aqueous solution of MOF has been employed for studying the interactions of MOF with different surfactants including neutral, cationic, and anionic types in water medium. Interestingly, the MOF can very selective sense Triton X-100 based micelle in water medium. During the sensing process the fluorescent monomer of the MOF gets accommodated at the palisade layer of Triton X-100 in water medium and this has also been justified by simple fluorescence spectral and FE-SEM microstructural analysis. Thus, a MOF of Mn(II) can act as a selective fluorescent sensor for Triton X-100 based organized medium in water. - Highlights: • Microstructural and crystallographic studies of a water-soluble MOF are performed. • The luminescent property of MOF in water medium is explored. • The interaction between Triton X-100 and the MOF in water medium is studied by fluorometric and microstructural analysis. • The MOF acts as a selective fluorometric sensor for the Triton X-100 based organized media in water. • The monomer of MOF presents in the Triton X-100 micelle in water.

  9. Fluorometric sensing of Triton X-100 based organized media in water by a MOF

    International Nuclear Information System (INIS)

    Dey, Biswajit; Mondal, Ranjan Kumar; Dhibar, Subhendu; Chattopadhyay, Asoke Prasun; Bhattacharya, Subhash Chandra

    2016-01-01

    The fluorescent property of the aqueous solution of a metal organic framework (MOF) of Mn(II), having a sedimentary rocks like microstructure in solid-state, has been investigated. The luminescent feature of the the aqueous solution of MOF has been employed for studying the interactions of MOF with different surfactants including neutral, cationic, and anionic types in water medium. Interestingly, the MOF can very selective sense Triton X-100 based micelle in water medium. During the sensing process the fluorescent monomer of the MOF gets accommodated at the palisade layer of Triton X-100 in water medium and this has also been justified by simple fluorescence spectral and FE-SEM microstructural analysis. Thus, a MOF of Mn(II) can act as a selective fluorescent sensor for Triton X-100 based organized medium in water. - Highlights: • Microstructural and crystallographic studies of a water-soluble MOF are performed. • The luminescent property of MOF in water medium is explored. • The interaction between Triton X-100 and the MOF in water medium is studied by fluorometric and microstructural analysis. • The MOF acts as a selective fluorometric sensor for the Triton X-100 based organized media in water. • The monomer of MOF presents in the Triton X-100 micelle in water.

  10. A fluorometric lateral flow assay for visual detection of nucleic acids using a digital camera readout.

    Science.gov (United States)

    Magiati, Maria; Sevastou, Areti; Kalogianni, Despina P

    2018-06-04

    A fluorometric lateral flow assay has been developed for the detection of nucleic acids. The fluorophores phycoerythrin (PE) and fluorescein isothiocyanate (FITC) were used as labels, while a common digital camera and a colored vinyl-sheet, acting as a cut-off optical filter, are used for fluorescence imaging. After DNA amplification by polymerase chain reaction (PCR), the biotinylated PCR product is hybridized to its complementary probe that carries a poly(dA) tail at 3΄ edge and then applied to the lateral flow strip. The hybrids are captured to the test zone of the strip by immobilized poly(dT) sequences and detected by streptavidin-fluorescein and streptavidin-phycoerythrin conjugates, through streptavidin-biotin interaction. The assay is widely applicable, simple, cost-effective, and offers a large multiplexing potential. Its performance is comparable to assays based on the use of streptavidin-gold nanoparticles conjugates. As low as 7.8 fmol of a ssDNA and 12.5 fmol of an amplified dsDNA target were detectable. Graphical abstract Schematic presentation of a fluorometric lateral flow assay based on fluorescein and phycoerythrin fluorescent labels for the detection of single-stranded (ssDNA) and double-stranded DNA (dsDNA) sequences and using a digital camera readout. SA: streptavidin, BSA: Bovine Serum Albumin, B: biotin, FITC: fluorescein isothiocyanate, PE: phycoerythrin, TZ: test zone, CZ: control zone.

  11. Vitamin E composition of some seed oils as determined by High Performance Liquid Chromatography with fluorometric detection

    NARCIS (Netherlands)

    Speek, A.J.; Schrijver, J.; Schreurs, W.H.P.

    1985-01-01

    A high‐performance liquid chromatographic (HPLC) method is described for the simultaneous analysis of E vitamers α‐, and β‐, γ‐ and δ‐tocopherol and α‐tocotrienol in seed oils. After diluting the oils with n‐hexane, E vitamers are separated by HPLC and detected fluorometrically. Standardization is

  12. Extraction/fluorometric determination of uranium with rhodamine B and 2-thenoyltrifluoroacetone

    International Nuclear Information System (INIS)

    Naganuma, Takeshi; Tuzuki, Satoshi; Jin, Jiye.

    1990-01-01

    A method for the fluorometric determination of uranium, based on a solvent extraction of an ion associate formed between Rhodamine B cation and 2-thenoyltrifluoroacetone(TTA)-metal chelate anion with benzene, is described. The procedure for the construction of the calibration curve is as follows. Varying amounts of uranium standard solution and 2 ml of 2 M ammonium acetate buffer solution are mixed. The solution is adjusted at pH 6.0 and 10 ml of 0.3 % Rhodamine B are added. It is then shaken for 5 min with 10 ml of 0.01 M TTA benzene solution. The fluoresence of the organic phase is measured at 545 nm (excitation) and 570 nm (emission) for uranyl-TTA-Rhodamine B complex. The fluorescence intensity is linearly related to the concentration of uranyl ion in the range of 0.05 ppm ot 1 ppm. (author)

  13. Uranium leaching analysis (IAEA method) and total uranium determination in caldasite by the fluorometric method

    International Nuclear Information System (INIS)

    Sardela, I.A.; Fujimori, K.

    1980-10-01

    Caldasite is a radioactive mineral known mostly for its high radioactive content (U and Th). It is found only at the Pocos de Caldas Alkaline Complex, States of Minas Gerais. Samples colected at Campos do Serrote, Taquari and Brigrada located in the alkaline complex were submitted to the fluorometric method of uranium analysis. The results show a good precision and close agreement with those obtained with gamma ray spectroscopy. IAEA uranium leaching analysis has also been applied to this mineral, but only 0,4% of the total content was dissolved. The uranium leaching was more intense on the samples that have smaller equivalent uranium than total uranium and it may be attributed to a higher range Rn gas escape from this mineral. (Author) [pt

  14. Fluorometric determination of free glucose and glucose 6-phosphate in cows' milk and other opaque matrices

    DEFF Research Database (Denmark)

    Larsen, Torben

    2015-01-01

    Analyses of free glucose and glucose 6-phosphate in milk have until now been dependent upon several time consuming and troublesome procedures. This has limited investigations in the area. The present article presents a new, reliable, analytical procedure, based on enzymatic degradation and fluoro......Analyses of free glucose and glucose 6-phosphate in milk have until now been dependent upon several time consuming and troublesome procedures. This has limited investigations in the area. The present article presents a new, reliable, analytical procedure, based on enzymatic degradation...... and fluorometric detection. Standards and control materials were based on milk that was stripped of intrinsic glucose and glucose 6-phosphate in order to obtain standards and samples based on the same matrix. The analysis works without pre-treatment of the samples, e.g. without centrifugation and precipitation...

  15. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    Science.gov (United States)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  16. Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants

    Science.gov (United States)

    Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki

    2015-01-01

    Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates for the enzymatic reaction. In this study, susceptibility of HIV mutations to drugs was evaluated by selective formation of three FL products after the enzymatic HIV-PR reaction. This proof-of-concept study indicates that the present HPLC-FL method could be an alternative to current phenotypic assays for the evaluation of HIV drug resistance. PMID:25988960

  17. Indirection and computer security.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Michael J.

    2011-09-01

    The discipline of computer science is built on indirection. David Wheeler famously said, 'All problems in computer science can be solved by another layer of indirection. But that usually will create another problem'. We propose that every computer security vulnerability is yet another problem created by the indirections in system designs and that focusing on the indirections involved is a better way to design, evaluate, and compare security solutions. We are not proposing that indirection be avoided when solving problems, but that understanding the relationships between indirections and vulnerabilities is key to securing computer systems. Using this perspective, we analyze common vulnerabilities that plague our computer systems, consider the effectiveness of currently available security solutions, and propose several new security solutions.

  18. Laser-based direct-write techniques for cell printing

    Energy Technology Data Exchange (ETDEWEB)

    Schiele, Nathan R; Corr, David T [Biomedical Engineering Department, Rensselaer Polytechnic Institute, Troy, NY (United States); Huang Yong [Department of Mechanical Engineering, Clemson University, Clemson, SC (United States); Raof, Nurazhani Abdul; Xie Yubing [College of Nanoscale Science and Engineering, University at Albany, SUNY, Albany, NY (United States); Chrisey, Douglas B, E-mail: schien@rpi.ed, E-mail: chrisd@rpi.ed [Material Science and Engineering Department, Rensselaer Polytechnic Institute, Troy, NY (United States)

    2010-09-15

    Fabrication of cellular constructs with spatial control of cell location ({+-}5 {mu}m) is essential to the advancement of a wide range of applications including tissue engineering, stem cell and cancer research. Precise cell placement, especially of multiple cell types in co- or multi-cultures and in three dimensions, can enable research possibilities otherwise impossible, such as the cell-by-cell assembly of complex cellular constructs. Laser-based direct writing, a printing technique first utilized in electronics applications, has been adapted to transfer living cells and other biological materials (e.g., enzymes, proteins and bioceramics). Many different cell types have been printed using laser-based direct writing, and this technique offers significant improvements when compared to conventional cell patterning techniques. The predominance of work to date has not been in application of the technique, but rather focused on demonstrating the ability of direct writing to pattern living cells, in a spatially precise manner, while maintaining cellular viability. This paper reviews laser-based additive direct-write techniques for cell printing, and the various cell types successfully laser direct-written that have applications in tissue engineering, stem cell and cancer research are highlighted. A particular focus is paid to process dynamics modeling and process-induced cell injury during laser-based cell direct writing. (topical review)

  19. Laser-based direct-write techniques for cell printing

    International Nuclear Information System (INIS)

    Schiele, Nathan R; Corr, David T; Huang Yong; Raof, Nurazhani Abdul; Xie Yubing; Chrisey, Douglas B

    2010-01-01

    Fabrication of cellular constructs with spatial control of cell location (±5 μm) is essential to the advancement of a wide range of applications including tissue engineering, stem cell and cancer research. Precise cell placement, especially of multiple cell types in co- or multi-cultures and in three dimensions, can enable research possibilities otherwise impossible, such as the cell-by-cell assembly of complex cellular constructs. Laser-based direct writing, a printing technique first utilized in electronics applications, has been adapted to transfer living cells and other biological materials (e.g., enzymes, proteins and bioceramics). Many different cell types have been printed using laser-based direct writing, and this technique offers significant improvements when compared to conventional cell patterning techniques. The predominance of work to date has not been in application of the technique, but rather focused on demonstrating the ability of direct writing to pattern living cells, in a spatially precise manner, while maintaining cellular viability. This paper reviews laser-based additive direct-write techniques for cell printing, and the various cell types successfully laser direct-written that have applications in tissue engineering, stem cell and cancer research are highlighted. A particular focus is paid to process dynamics modeling and process-induced cell injury during laser-based cell direct writing. (topical review)

  20. Enzymatic-fluorometric analyses for glutamine, glutamate and free amino groups in protein-free plasma and milk

    DEFF Research Database (Denmark)

    Larsen, Torben; Fernández, Carlos J.

    2017-01-01

    This Technical Research Communication describes new analytical methods for free, unbound glutamic acid and glutamine in protein-free blood plasma and milk and introduces the use of quantitation of free amino groups in the same matrices for descriptive and analytical purposes. The present enzymatic......-fluorometric methods are easily performed within one working day, allowing for ‘high throughput’ assays of animal trials. These assays could support and enable further studies in lactation physiology with the objective of improved metabolic health....

  1. Synthesis of nitrogen- and iron-containing carbon dots, and their application to colorimetric and fluorometric determination of dopamine

    International Nuclear Information System (INIS)

    Wang, Bin; Chen, Yanfen; Wu, Yuanya; Weng, Bo; Liu, Yingshuai; Li, Chang Ming

    2016-01-01

    Nitrogen- and iron-containing carbon dots (N,Fe-CDs) are synthesized by hydrothermal treatment of branched polyethylenimine (BPEI) and hemin at 180 °C. The N,Fe-CDs are mainly doped with nitrogen and trace amounts of iron(III). The N,Fe-CDs also display intrinsic fluorescence with excitation/emission maxima at 365/452 nm and a quantum yield of 27 %. The nanodots are shown to act as peroxidase mimics by catalyzing the oxidation of tetramethylbenzidine (TMB) by hydrogen peroxide to form a blue product whose quantity can be determined by photometry at 652 nm. This was exploited to design colorimetric and fluorometric assays for dopamine (DA). The colorimetric assay is based on the oxidation of DA by H2O2 in presence of the N,Fe-CDs and TMB. It has an instrumental detection limit of 40 nM (at an S/N ratio of 3), and a visual detection limit of 0.4 μM. The fluorometric assay is based on an inner filter effect that is caused by the formation of oxidized TMB which overlaps (and absorbs) the emission of the N,Fe-CDs located at 452 nm. The fluorometric detection limit is as low as 20 nM (at an S/N ratio of 3). (author)

  2. Rapid fluorometric determination of perfluorooctanoic acid by its quenching effect on the fluorescence of quantum dots

    International Nuclear Information System (INIS)

    Liu, Qi; Huang, Aizhen; Wang, Nan; Zheng, Guan; Zhu, Lihua

    2015-01-01

    Analysis of perfluorooctanoic acid (PFOA) usually requires a combination of high-performance liquid chromatography and mass spectrometry, which is expensive and time-consuming. In the present work, water-soluble CdS quantum dots (QDs) were employed to develop a simple and rapid fluorometric method for the determination of PFOA. Strongly fluorescent CdS QDs were prepared by using 3-mercaptopropionic acid (MPA) as a stabilizer. It was observed that PFOA strongly quenched the fluorescence emission of the MPA-CdS QDs because PFOA promotes the aggregation of MPA-CdS QDs through a fluorine–fluorine affinity interaction. Under optimum conditions, the fluorescence intensity of MPA-CdS QDs was observed to decrease linearly with an increase in the concentration of PFOA from 0.5 to 40 μmol L −1 , with a limit of detection of 0.3 μmol L −1 . This new method was successfully implemented for the analysis of PFOA-spiked textile samples, with recoveries ranging from 95% to 113%. - Highlights: • PFOA significantly quenched the fluorescence emission of quantum dots (QDs). • A rapid and simple fluorescence sensor was proposed for determining PFOA by QDs. • PFOA determination could be completed within approximately 10 min. • The developed method had a working range of 0.5 to 40 μmol L −1 and a detection limit of 0.3 μmol L −1

  3. A sol-gel based molecular imprint incorporating carbon dots for fluorometric determination of nicotinic acid

    International Nuclear Information System (INIS)

    Zuo, Pengli; Gao, Junfa; Liu, Jianha; Zhao, Mingming; Zhao, Jiahong; Peng, Jun; Zuo, Pengjian; He, Hua

    2016-01-01

    We are introducing functionalized carbon dots (C-dots) coated with a shell of molecularly imprinted sol-gel as a new tool in molecular imprint-based detection. Specifically, an imprint recognizing nicotinic acid (NA) was prepared in two steps. The first involves pyrolytic decomposition of citric acid in the presence of aminopropyltriethoxysilane to yield triethoxysilyl-modified C-dots with a typical size of 2.8 ± 1.1 nm. These are then polycondensed in the presence of tetraethoxysilane and NA at room temperature to give spherical silica nanoparticles (SiNPs) with a typical size of ∼300 nm and containing C-dots and NA in the silica matrix. NA was then removed by extraction. The resulting SiNPs are well permeable to NA, photostable, display strong blue luminescence and can bind NA fairly selectively. The fluorometric detection scheme is based on the finding that increasing concentrations of NA quench the fluorescence of the C-dots in the SiNPs. NA can be determined by this method in the 0.5 to 10.5 μM concentration range, with a 12.6 nM detection limit. The composite was successfully utilized as a fluorescent probe for the determination of NA in spiked human urine samples. The method is believed to have a wider scope in being applicable to other analytes that are capable of quenching the fluorescence of C-dots. (author)

  4. Fluorometric sensing of endotoxin based on aggregation of CTAB capped gold nanospheres

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Ida Evangeline [Centre for Nanobiotechnology, VIT University, Vellore 632014 (India); Raichur, Ashok M. [Department of Materials Engineering, Indian Institute of Science, Bangalore 560012 (India); Nanotechnology and Water Sustainability Unit, University of South Africa, Florida Park 1709 Johannesburg (South Africa); Chandrasekaran, N. [Centre for Nanobiotechnology, VIT University, Vellore 632014 (India); Mukherjee, Amitava, E-mail: amit.mookerjea@gmail.com [Centre for Nanobiotechnology, VIT University, Vellore 632014 (India)

    2016-10-15

    Gold nanoparticles (GNPs) of different sizes were used to carry out comparative fluorometric detection study on endotoxin. At excitation wavelength, 308 nm the GNPs exhibited strong emission intensity at wavelength 421 nm with varying intensities at 215.122, 234.965 and 262.551 for 15 nm (GNPs-I), 30 nm (GNPs-II) and 40 nm (GNPs-III), respectively. The different sizes of GNPs were interacted with endotoxin to study the effect of GNPs size on endotoxin detection. The electrostatic interaction between GNPs (GNPs-I, II, and III) and endotoxin led to the enhancement of the fluorescence intensities. The sensitivity of endotoxin detection was improved significantly by decreasing the size of the GNPs to 15 nm (GNPs-I). The endotoxin detection limit using GNPs-I was theoretically calculated to be 0.56×10{sup −9} M using the formula 3SD/slope, and it was able to detect lower levels of endotoxin when compared to GNPs-II or GNPs-III. The GNPs-I showed excellent selectivity for endotoxin detection with the optimized pH and volumetric ratio. Most importantly the optimized size was successfully used to detect endotoxin in real samples (milk samples and fruit juices) with a recovery rate of 98–105%.

  5. A New Coumarin-Based Colorimetric and Fluorometric Sensor for Cu{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    An, Kyounglyong; Jun, Kun [Korea Research Institute of Chemical Technology, Daejeon (Korea, Republic of); Park, Koon Ha [Chungnam National Univ., Daejeon (Korea, Republic of)

    2014-07-15

    We have developed a new colorimetric and fluorescent 'turn-off' sensor for Cu{sup 2+} based on coumarin Shiff base of hydroxycinnamaldehyde. It displays a 50 nm red-shift of maximum absorption band with color change from colorless to greenish-yellow upon addition of Cu{sup 2+} in 10 mM tris-HCl buffer solution (acetonitrile/water = 9:1, pH = 7.01). And also remarkable fluorescence quenching was observed upon the addition of Cu{sup 2+}. The 1:2 stoichiometry of sensor complex (sensor A + Cu{sup 2+}) was confirmed by Job's plot based on absorption titration. Chemosensors, small chemical compounds that sense the presence of analytes or energy, typically consist of two components: a receptor moiety that interacts with the target analytes and a read-out system that signals binding. And one of the most utilized research tool for the study of chemosensors employs a colorimetric and fluorometric spectroscopic techniques. So far successful reports on metal ion sensors have been documented including our recent result. Many different kinds of optical or fluorescent sensors have several advantages (such as high sensitivity and selectivity, non-destructive analysis, low cost and real-time monitoring), which allow naked-eye detection of color and fluorescent emission change upon metal ion binding without the use of any expensive spectroscopic equipment.

  6. Laser-based gas sensors keep moisture out of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2006-07-15

    Natural gas often contains contaminants that cause corrosion, and long-term deterioration, and must be cleaned and brought to pipeline standards before it can be delivered to high-pressure, long-distance pipelines. Many older sensors produce false data that can result in contaminated gas getting through. This article presented details of the SpectraSensor, a new laser-based sensor technology used by the El Paso Natural Gas Company (EPNG). The SpectraSensor is comprised of a tunable diode laser (TDL) based technology developed by the National American Space Agency (NASA). The gas analyzer provides non-contact measurement of moisture, carbon dioxide, and other corrosives in natural gas pipelines, and the tunable laser-based gas sensors are fast, accurate, and flexible. Producers can monitor El Paso's gas analyzer readings by capturing the electronic signal from El Paso's unit via a SCADA system and view the readings from control rooms. While initial purchase price is higher than more problematic surface-based gas sensors, an evaluation of the technology has indicated that maintenance savings alone may provide an almost immediate return on investments. Unlike electrochemical and crystal gas sensors, laser-based gas analyzers do not come into direct contact with any substances, a fact which practically eliminates maintenance and operational costs. Studies have shown that the cost of operating conventional electrochemical sensors can result in a cumulative annual expense exceeding $50,000 per unit including labour; recalibration and rebuilding; back-up sensor heads; and gas dehydration and tariffs. 1 fig.

  7. Laser-Based Maintenance and Repair Technologies for Reactor Components

    International Nuclear Information System (INIS)

    Masaki Yoda; Naruhiko Mukai; Makoto Ochiai; Masataka Tamura; Satoshi Okada; Katsuhiko Sato; Motohiko Kimura; Yuji Sano; Noboru Saito; Seishi Shima; Tetsuo Yamamoto

    2004-01-01

    Toshiba has developed various laser-based maintenance and repair technologies and applied them to existing nuclear power plants. Laser-based technology is considered to be the best tool for remote processing in nuclear power plants, and particularly so for the maintenance and repair of reactor core components. Accessibility could be drastically improved by a simple handling system owing to the absence of reactive force against laser irradiation and the flexible optical fiber. For the preventive maintenance, laser peening (LP) technology was developed and applied to reactor components in operating BWR plants. LP is a novel process to improve residual stress from tensile to compressive on material surface layer by irradiating focused high-power laser pulses in water. We have developed a fiber-delivered LP system as a preventive maintenance measure against stress corrosion cracking (SCC). Laser ultrasonic testing (LUT) has a great potential to be applied to the remote inspection of reactor components. Laser-induced surface acoustic wave (SAW) inspection system was developed using a compact probe with a multi-mode optical fiber and an interferometer. The developed system successfully detected a micro slit of 0.5 mm depth on weld metal and heat-affected zone (HAZ). An artificial SCC was also detected by the system. We are developing a new LP system combined with LUT to treat the inner surface of bottom-mounted instruments (BMI) of PWR plants. Underwater laser seal welding (LSW) technology was also developed to apply surface crack. LSW is expected to isolate the crack tip from corrosive water environment and to stop the propagation of the crack. Rapid heating and cooling of the process minimize the heat effect, which extends the applicability to neutron-irradiated material. This paper describes recent advances in the development and application of such laser-based technologies. (authors)

  8. Rapid analysis of steels using laser-based techniques

    International Nuclear Information System (INIS)

    Cremers, D.A.; Archuleta, F.L.; Dilworth, H.C.

    1985-01-01

    Based on the data obtained by this study, we conclude that laser-based techniques can be used to provide at least semi-quantitative information about the elemental composition of molten steel. Of the two techniques investigated here, the Sample-Only method appears preferable to the LIBS (laser-induced breakdown spectroscopy) method because of its superior analytical performance. In addition, the Sample-Only method would probably be easier to incorporate into a steel plant environment. However, before either technique can be applied to steel monitoring, additional research is needed

  9. Laser-Based Diagnostic Measurements of Low Emissions Combustor Concepts

    Science.gov (United States)

    Hicks, Yolanda R.

    2011-01-01

    This presentation provides a summary of primarily laser-based measurement techniques we use at NASA Glenn Research Center to characterize fuel injection, fuel/air mixing, and combustion. The report highlights using Planar Laser-Induced Fluorescence, Particle Image Velocimetry, and Phase Doppler Interferometry to obtain fuel injector patternation, fuel and air velocities, and fuel drop sizes and turbulence intensities during combustion. We also present a brief comparison between combustors burning standard JP-8 Jet fuel and an alternative fuels. For this comparison, we used flame chemiluminescence and high speed imaging.

  10. A laser based reusable microjet injector for transdermal drug delivery

    Science.gov (United States)

    Han, Tae-hee; Yoh, Jack J.

    2010-05-01

    A laser based needle-free liquid drug injection device has been developed. A laser beam is focused inside the liquid contained in the rubber chamber of microscale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is 125 μm and the injected microjet reaches an average velocity of 264 m/s. This device adds the time-varying feature of microjet to the current state of liquid injection for drug delivery.

  11. Efficient TEA CO2 laser based coating removal system

    CSIR Research Space (South Africa)

    Prinsloo, FJ

    2007-04-01

    Full Text Available stream_source_info Prinsloo_2007.pdf.txt stream_content_type text/plain stream_size 11617 Content-Encoding UTF-8 stream_name Prinsloo_2007.pdf.txt Content-Type text/plain; charset=UTF-8 Efficient TEA CO2 laser based... by keeping energy density below the damage threshold. The advantage of a pulsed TEA CO2 laser system is that a laser frequency and temporal profile can be chosen to maximize paint removal and concurrently minimize substrate damage. To achieve...

  12. Non-Contact Laser Based Ultrasound Evaluation of Canned Foods

    Science.gov (United States)

    Shelton, David

    2005-03-01

    Laser-Based Ultrasound detection was used to measure the velocity of compression waves transmitted through canned foods. Condensed broth, canned pasta, and non-condensed soup were evaluated in these experiments. Homodyne adaptive optics resulted in measurements that were more accurate than the traditional heterodyne method, as well as yielding a 10 dB gain in signal to noise. A-Scans measured the velocity of ultrasound sent through the center of the can and were able to distinguish the quantity of food stuff in its path, as well as distinguish between meat and potato. B-Scans investigated the heterogeneity of the sample’s contents. The evaluation of canned foods was completely non-contact and would be suitable for continuous monitoring in production. These results were verified by conducting the same experiments with a contact piezo transducer. Although the contact method yields a higher signal to noise ratio than the non-contact method, Laser-Based Ultrasound was able to detect surface waves the contact transducer could not.

  13. Fluorometric determination of nucleic acids based on the use of polydopamine nanotubes and target-induced strand displacement amplification.

    Science.gov (United States)

    Ge, Jia; Bai, Dong-Mei; -Geng, Xin; Hu, Ya-Lei; Cai, Qi-Yong; Xing, Ke; Zhang, Lin; Li, Zhao-Hui

    2018-01-10

    The authors describe a fluorometric method for the quantitation of nucleic acids by combining (a) cycled strand displacement amplification, (b) the unique features of the DNA probe SYBR Green, and (c) polydopamine nanotubes. SYBR Green undergoes strong fluorescence enhancement upon intercalation into double-stranded DNA (dsDNA). The polydopamine nanotubes selectively adsorb single-stranded DNA (ssDNA) and molecular beacons. In the absence of target DNA, the molecular beacon, primer and SYBR Green are adsorbed on the surface of polydopamine nanotubes. This results in quenching of the fluorescence of SYBR Green, typically measured at excitation/emission wavelengths of 488/518 nm. Upon addition of analyte (target DNA) and polymerase, the stem of the molecular beacon is opened so that it can bind to the primer. This triggers target strand displacement polymerization, during which dsDNA is synthesized. The hybridized target is then displaced due to the strand displacement activity of the polymerase. The displaced target hybridizes with another molecular beacon. This triggers the next round of polymerization. Consequently, a large amount of dsDNA is formed which is detected by addition of SYBR Green. Thus, sensitive and selective fluorometric detection is realized. The fluorescent sensing strategy shows very good analytical performances towards DNA detection, such as a wide linear range from 0.05 to 25 nM with a low limit of detection of 20 pM. Graphical abstract Schematic of a fluorometric strategy for highly sensitive and selective determination of nucleic acids by combining strand displacement amplification and the unique features of SYBR Green I (SG) and polydopamine nanotubes.

  14. Rapid fluorometric determination of perfluorooctanoic acid by its quenching effect on the fluorescence of quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qi; Huang, Aizhen; Wang, Nan, E-mail: nwang@hust.edu.cn; Zheng, Guan; Zhu, Lihua

    2015-05-15

    Analysis of perfluorooctanoic acid (PFOA) usually requires a combination of high-performance liquid chromatography and mass spectrometry, which is expensive and time-consuming. In the present work, water-soluble CdS quantum dots (QDs) were employed to develop a simple and rapid fluorometric method for the determination of PFOA. Strongly fluorescent CdS QDs were prepared by using 3-mercaptopropionic acid (MPA) as a stabilizer. It was observed that PFOA strongly quenched the fluorescence emission of the MPA-CdS QDs because PFOA promotes the aggregation of MPA-CdS QDs through a fluorine–fluorine affinity interaction. Under optimum conditions, the fluorescence intensity of MPA-CdS QDs was observed to decrease linearly with an increase in the concentration of PFOA from 0.5 to 40 μmol L{sup −1}, with a limit of detection of 0.3 μmol L{sup −1}. This new method was successfully implemented for the analysis of PFOA-spiked textile samples, with recoveries ranging from 95% to 113%. - Highlights: • PFOA significantly quenched the fluorescence emission of quantum dots (QDs). • A rapid and simple fluorescence sensor was proposed for determining PFOA by QDs. • PFOA determination could be completed within approximately 10 min. • The developed method had a working range of 0.5 to 40 μmol L{sup −1} and a detection limit of 0.3 μmol L{sup −1}.

  15. DNA aptamer selection and aptamer-based fluorometric displacement assay for the hepatotoxin microcystin-RR

    International Nuclear Information System (INIS)

    Wu, Shijia; Li, Qi; Duan, Nuo; Wang, Zhouping; Ma, Haile

    2016-01-01

    Microcystin-RR (MC-RR) is a highly acute hepatotoxin produced by cyanobacteria. It is harmful to both humans and the environment. A novel aptamer was identified by the systemic evolution of ligands by exponential enrichment (SELEX) method as a recognition element for determination of MC-RR in aquatic products. The graphene oxide (GO) SELEX strategy was adopted to generate aptamers with high affinity and specificity. Of the 50 aptamer candidates tested, sequence RR-33 was found to display high affinity and selectivity, with a dissociation constant of 45.7 ± 6.8 nM. Aptamer RR-33 therefore was used as the recognition element in a fluorometric assay that proceeds as follows: (1) Biotinylated aptamer RR-33 is immobilized on the streptavidinylated wells of a microtiterplate, and carboxyfluorescein (FAM) labelled complementary DNA is then allowed to hybridize. (2) After removal of excess (unbound) cDNA, sample containing MC-RR is added and incubated at 37 °C for 2 h. (3) Displaced free cDNA is washed away and fluorescence intensity measured at excitation/emission wavelengths of 490/515 nm. The calibration plot is linear in the 0.20 to 2.5 ng·mL −1 concentration range, and the limit of detection is 80 pg·mL −1 . The results indicate that the GO-SELEX technology is appropriate for the screening of aptamers against small-molecule toxins. The detection scheme was applied to the determination of MC-RR in (spiked) water, mussel and fish and gave recoveries between 91 and 98 %. The method compares favorably to a known ELISA. Conceivably, this kind of assay is applicable to other toxins for which appropriate aptamers are available. (author)

  16. Fluorometric graphene oxide-based detection of Salmonella enteritis using a truncated DNA aptamer.

    Science.gov (United States)

    Chinnappan, Raja; AlAmer, Saleh; Eissa, Shimaa; Rahamn, Anas Abdel; Abu Salah, Khalid M; Zourob, Mohammed

    2017-12-18

    The work describes a fluorescence-based study for mapping the highest affinity truncated aptamer from the full length sequence and its integration in a graphene oxide platform for the detection of Salmonella enteriditis. To identify the best truncated sequence, molecular beacons and a displacement assay design are applied. In the fluorescence displacement assay, the truncated aptamer was hybridized with fluorescein and quencher-labeled complementary sequences to form a fluorescence/quencher pair. In the presence of S. enteritidis, the aptamer dissociates from the complementary labeled oligonucleotides and thus, the fluorescein/quencher pair becomes physically separated. This leads to an increase in fluorescence intensity. One of the truncated aptamers identified has a 2-fold lower dissociation constant (3.2 nM) compared to its full length aptamer (6.3 nM). The truncated aptamer selected in this process was used to develop a fluorometric graphene oxide (GO) based assay. If fluorescein-labeled aptamer is adsorbed on GO via π stacking interaction, fluorescence is quenched. However, in the presence of target (S. enteriditis), the labeled aptamers is released from surface to form a stable complex with the bacteria and fluorescence is restored, depending on the quantity of bacteria being present. The resulting assay has an unsurpassed detection limit of 25 cfu·mL -1 in the best case. The cross reactivity to Salmonella typhimurium, Staphylococcus aureus and Escherichia coli is negligible. The assay was applied to analyze doped milk samples for and gave good recovery. Thus, we believe that the truncated aptamer/graphene oxide platform is a potential tool for the detection of S. Enteritidis. Graphical abstract Fluorescently labelled aptamer against Salmonella enteritidis was adsorbed on the surface of graphene oxide by π-stacking interaction. This results in quenching of the fluorescence of the label. Addition of Salmonella enteritidis restores fluorescence, and this

  17. Pedal indirect lymphangiography

    International Nuclear Information System (INIS)

    Lee, Kil Woo; Hong, Myung Sun; Kim, In Jae

    1994-01-01

    Recently, indirect lymphangiography has been developed as a relatively good and noninvasive imaging modality of the lymphatic system at extremities. But the disadvantage of the indirect lymphangiography is a low contrast ratio between the surrounding tissues and the contrast media in lymphatic vessels, because dimeric nonionic contrast media is water soluble and diluted in the proximal leg lymphatic vessels. We could have relatively better image than previously published images for the leg lymphatic system, when we injected contrast media with adequate high pressure in intradermal space of the interdigital areas at the foot dorsum. So, we would like to report the results. We could study all 9 lymphedemas(primary: 6, secondary: 3) from April 1990 to May 1993 on outpatient base. They were diagnosed as lymphedema clinically and radiologically. Ten ml of dimeric nonionic aget, iotrolan(Isovist 300) was injected into intradermal space with five 30-gauge needles. The injection speed was more than 0.2 ml/min. We have done one side pedal lymphangiogram in 30 minutes. The evaluation of the anterior superficial lymphatics was according to the criteria of the Weissleder. The results were as follows: 1. All lymphatic vessels from foot to inguinal area could be visualized. 2. Two or three inferior inguinal lymph nodes could be visualized about 42%. 3. The most common abnormal finding of the lymphedma was the neovascularization of the lymphatics on indirect pedal lymphangiogram. If we use adequate technique relatively high pressure injection, correct intradermal needle insertion, adequate soft tissue exposure technique indirect lymphangiography is considered to be a safe and noninvasive imaging modality for the evaluation of the lymphedema of lower extremity lymphatics including inferior inguinal lymph nodes

  18. Laser-based instrumentation for the detection of chemical agents

    International Nuclear Information System (INIS)

    Hartford, A. Jr.; Sander, R.K.; Quigley, G.P.; Radziemski, L.J.; Cremers, D.A.

    1982-01-01

    Several laser-based techniques are being evaluated for the remote, point, and surface detection of chemical agents. Among the methods under investigation are optoacoustic spectroscopy, laser-induced breakdown spectroscopy (LIBS), and synchronous detection of laser-induced fluorescence (SDLIF). Optoacoustic detection has already been shown to be capable of extremely sensitive point detection. Its application to remote sensing of chemical agents is currently being evaluated. Atomic emission from the region of a laser-generated plasma has been used to identify the characteristic elements contained in nerve (P and F) and blister (S and Cl) agents. Employing this LIBS approach, detection of chemical agent simulants dispersed in air and adsorbed on a variety of surfaces has been achieved. Synchronous detection of laser-induced fluorescence provides an attractive alternative to conventional LIF, in that an artificial narrowing of the fluorescence emission is obtained. The application of this technique to chemical agent simulants has been successfully demonstrated. 19 figures

  19. Circumvention of noise contributions in fiber laser based frequency combs.

    Science.gov (United States)

    Benkler, Erik; Telle, Harald; Zach, Armin; Tauser, Florian

    2005-07-25

    We investigate the performance of an Er:fiber laser based femtosecond frequency comb for precision metrological applications. Instead of an active stabilization of the comb, the fluctuations of the carrier-envelope offset phase, the repetition phase, and the phase of the beat from a comb line with an optical reference are synchronously detected. We show that these fluctuations can be effectively eliminated by exploiting their known correlation. In our experimental scheme, we utilize two identically constructed frequency combs for the measurement of the fluctuations, rejecting the influence of a shared optical reference. From measuring a white frequency noise level, we demonstrate that a fractional frequency instability better than 1.4 x 10(-14) for 1 s averaging time can be achieved in frequency metrology applications using the Er:fiber based frequency comb.

  20. Designing and testing a laser-based vibratory sensor

    Science.gov (United States)

    Nath, G.

    2018-04-01

    Sensor technology has proved its importance, not only in the range of few-meter applications in different fields, but in micro, nano, atomic and sub-atomic-sized objects. The present work describes the designing of a laser-based vibratory sensor using a He-Ne laser as the signal source. The received characteristics of the signal are mainly the frequency and amplitude of the vibration from which the physical parameters such as energy, power and absorption coefficients of the material are determined, which enables us to provide information of the hidden target or object. This laboratory-designed sensor finds application in different local phenomena as well as laboratory practical activity for students.

  1. Modeling of photoluminescence in laser-based lighting systems

    Science.gov (United States)

    Chatzizyrli, Elisavet; Tinne, Nadine; Lachmayer, Roland; Neumann, Jörg; Kracht, Dietmar

    2017-12-01

    The development of laser-based lighting systems has been the latest step towards a revolution in illumination technology brought about by solid-state lighting. Laser-activated remote phosphor systems produce white light sources with significantly higher luminance than LEDs. The weak point of such systems is often considered to be the conversion element. The high-intensity exciting laser beam in combination with the limited thermal conductivity of ceramic phosphor materials leads to thermal quenching, the phenomenon in which the emission efficiency decreases as temperature rises. For this reason, the aim of the presented study is the modeling of remote phosphor systems in order to investigate their thermal limitations and to calculate the parameters for optimizing the efficiency of such systems. The common approach to simulate remote phosphor systems utilizes a combination of different tools such as ray tracing algorithms and wave optics tools for describing the incident and converted light, whereas the modeling of the conversion process itself, i.e. photoluminescence, in most cases is circumvented by using the absorption and emission spectra of the phosphor material. In this study, we describe the processes involved in luminescence quantum-mechanically using the single-configurational-coordinate diagram as well as the Franck-Condon principle and propose a simulation model that incorporates the temperature dependence of these processes. Following an increasing awareness of climate change and environmental issues, the development of ecologically friendly lighting systems featuring low power consumption and high luminous efficiency is imperative more than ever. The better understanding of laser-based lighting systems is an important step towards that aim as they may improve on LEDs in the near future.

  2. Fluorometric determination of samarium and europium in rare earth minerals with. beta. -diketoneternary complex

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H; Hiraki, K; Nishikawa, Y [Kinki Univ., Higashi-Osaka, Osaka (Japan). Faculty of Science and Technology

    1981-07-01

    This communication reported the optimum conditions for the fluorometric determination of these ions, and the method was adopted in the simultaneous determination of samarium and europium in xenotime and monazite minerals. From the experimental results on the effect of diverse ions and the extraction pH of the aqueous phase, it became clear that TTA-TOPO hexane method was the best system for the determination of samarium and europium because of the highest fluorescence sensitivity of the ternary complex, and also because the lower extraction pH eliminated the effect of diverse ions. Moreover, the very high detection limit (2 ppb) of Sm was achieved by the use of a red sensitive photomultiplier. Which was used at 644 nm, and that of Eu (0.02 ppb) at 614 nm. The procedure was established as follows: The rare earth minerals (xenotime, monazite) sample was treated with hot conc. H/sub 2/SO/sub 4/ and twice precipitated with 0.5 mol dm/sup -3/ oxalic acid (pH was adjusted to 2.0 -- 2.2). Then the precipitate was filtered and ignited to give the rare earth oxide. Fifty milligrams of the oxide was dissolved in HCl and diluted with water in order to obtain the solution containing 5 ..mu..g cm/sup -3/ rare earth oxide. An aliquot of the solution ((1.0 -- 3.0) cm/sup 3/) was adjusted to pH 5.5 with sodium acetate and shaken with 1 x 10/sup -4/ mol dm/sup -3/ TTA- 2 x 10/sup -2/ mol dm/sup -3/ TOPO hexane solution. Then the fluorescence intensity of the organic layer was measured at 644 nm for Sm and 614 nm for Eu. In this procedure, the recovery of Sm and Eu was found to be about 96%. Xenotime contained 0.70% of Sm and 0.004% of Eu, and monazite contained 1.84% of Sm and 0.003% of Eu.

  3. CONTRIBUTION OF INDIRECT TAXES

    Directory of Open Access Journals (Sweden)

    CHIRCULESCU MARIA FELICIA

    2015-08-01

    Full Text Available The work is based on the fact that at any time and in any society, taxation is regarded as undesirable for all taxpayers. The existence and it's manifestation is justified, because the operation of any company involves costs that must be covered by sufficient resources. Since ancient times, each state has adopted its own tax system, more or less perfected, as the state has experienced a greater or lesser economic and military power At the base of this work stays the fact that tax systems are a key factor influencing the overall efficiency of the economy. They determine the size tendency to save, invest and work, influencing the increase in production and employment, which is essential sights integral economic strategy, making tax reform an important component of economic reform. This paper aims to analyze the indirect taxes and their contribution to the public revenues in Romania, the purpose paper contains an analysis based on statistical series as indirect taxation is where tax harmonization was possible. Through analyzes, the paper aims to provide answers to the problem of the contradiction between the growing need for budgetary revenues, which entails a continuous amplification and diversification of taxation, on the one hand, and the need to stimulate economic development, on the other hand. The harmonization of indirect taxation had been achieved since this touches the free movement of goods and the freedom to supply services, not being able to say the same thing about direct taxation, which is why the European Community Treaty does not specify expressly the alignment of direct taxation, considering that direct taxation is a matter of Internal Policies that, for a country free option.

  4. Comparative Study of the New Colorimetric VITEK 2 Yeast Identification Card versus the Older Fluorometric Card and of CHROMagar Candida as a Source Medium with the New Card

    OpenAIRE

    Aubertine, C. L.; Rivera, M.; Rohan, S. M.; Larone, D. H.

    2006-01-01

    The new VITEK 2 colorimetric card was compared to the previous fluorometric card for identification of yeast. API 20C was considered the “gold standard.” The new card consistently performed better than the older card. Isolates from CHROMagar Candida plates were identified equally as well as those from Sabouraud dextrose agar.

  5. Dental hard tissue characterization using laser-based ultrasonics

    Science.gov (United States)

    Blodgett, David W.; Massey, Ward L.

    2003-07-01

    Dental health care and research workers require a means of imaging the structures within teeth in vivo. One critical need is the detection of tooth decay in its early stages. If decay can be detected early enough, the process can be monitored and interventional procedures, such as fluoride washes and controlled diet, can be initiated to help re-mineralize the tooth. Currently employed x-ray imaging is limited in its ability to visualize interfaces and incapable of detecting decay at a stage early enough to avoid invasive cavity preparation followed by a restoration. To this end, non-destructive and non-contact in vitro measurements on extracted human molars using laser-based ultrasonics are presented. Broadband ultrasonic waves are excited in the extracted sections by using a pulsed carbon-dioxide (CO2) laser operating in a region of high optical absorption in the dental hard tissues. Optical interferometric detection of the ultrasonic wave surface displacements in accomplished with a path-stabilized Michelson-type interferometer. Results for bulk and surface in-vitro characterization of caries are presented on extracted molars with pre-existing caries.

  6. Detecting Molecular Properties by Various Laser-Based Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hsin, Tse-Ming [Iowa State Univ., Ames, IA (United States)

    2007-01-01

    Four different laser-based techniques were applied to study physical and chemical characteristics of biomolecules and dye molecules. These techniques are liole burning spectroscopy, single molecule spectroscopy, time-resolved coherent anti-Stokes Raman spectroscopy and laser-induced fluorescence microscopy. Results from hole burning and single molecule spectroscopy suggested that two antenna states (C708 & C714) of photosystem I from cyanobacterium Synechocystis PCC 6803 are connected by effective energy transfer and the corresponding energy transfer time is ~6 ps. In addition, results from hole burning spectroscopy indicated that the chlorophyll dimer of the C714 state has a large distribution of the dimer geometry. Direct observation of vibrational peaks and evolution of coumarin 153 in the electronic excited state was demonstrated by using the fs/ps CARS, a variation of time-resolved coherent anti-Stokes Raman spectroscopy. In three different solvents, methanol, acetonitrile, and butanol, a vibration peak related to the stretch of the carbonyl group exhibits different relaxation dynamics. Laser-induced fluorescence microscopy, along with the biomimetic containers-liposomes, allows the measurement of the enzymatic activity of individual alkaline phosphatase from bovine intestinal mucosa without potential interferences from glass surfaces. The result showed a wide distribution of the enzyme reactivity. Protein structural variation is one of the major reasons that are responsible for this highly heterogeneous behavior.

  7. Virtual environment assessment for laser-based vision surface profiling

    Science.gov (United States)

    ElSoussi, Adnane; Al Alami, Abed ElRahman; Abu-Nabah, Bassam A.

    2015-03-01

    Oil and gas businesses have been raising the demand from original equipment manufacturers (OEMs) to implement a reliable metrology method in assessing surface profiles of welds before and after grinding. This certainly mandates the deviation from the commonly used surface measurement gauges, which are not only operator dependent, but also limited to discrete measurements along the weld. Due to its potential accuracy and speed, the use of laser-based vision surface profiling systems have been progressively rising as part of manufacturing quality control. This effort presents a virtual environment that lends itself for developing and evaluating existing laser vision sensor (LVS) calibration and measurement techniques. A combination of two known calibration techniques is implemented to deliver a calibrated LVS system. System calibration is implemented virtually and experimentally to scan simulated and 3D printed features of known profiles, respectively. Scanned data is inverted and compared with the input profiles to validate the virtual environment capability for LVS surface profiling and preliminary assess the measurement technique for weld profiling applications. Moreover, this effort brings 3D scanning capability a step closer towards robust quality control applications in a manufacturing environment.

  8. Laser-Based and Ultra-Portable Gas Sensor for Indoor and Outdoor Formaldehyde (HCHO) Monitoring

    Science.gov (United States)

    Shutter, J. D.; Allen, N.; Paul, J.; Thiebaud, J.; So, S.; Scherer, J. J.; Keutsch, F. N.

    2017-12-01

    While used as a key tracer of oxidative chemistry in the atmosphere, formaldehyde (HCHO) is also a known human carcinogen and is listed and regulated by the United States EPA as a hazardous air pollutant. Combustion processes and photochemical oxidation of volatile organic compounds (VOCs) are the major outdoor sources of HCHO, and building materials and household products are ubiquitous sources of indoor HCHO. Due to the ease with which humans can be exposed to HCHO, it is imperative to monitor levels of both indoor and outdoor HCHO exposure in both short and long-term studies.High-quality direct and indirect methods of quantifying HCHO mixing ratios exist, but instrument size and user-friendliness can make them cumbersome or impractical for certain types of indoor and long-term outdoor measurements. In this study, we present urban HCHO measurements by using a new, commercially-available, ppbv-level accurate HCHO gas sensor (Aeris Technologies' MIRA Pico VOC Laser-Based Gas Analyzer) that is highly portable (29 cm x 20 cm x 10 cm), lightweight (3 kg), easy-to-use, and has low power (15 W) consumption. Using an ultra-compact multipass cell, an absorption path length of 13 m is achieved, resulting in a sensor capable of achieving ppbv/s sensitivity levels with no significant spectral interferences.To demonstrate the utility of the gas sensor for emissions measurements, a GPS was attached to the sensor's housing in order to map mobile HCHO measurements in real-time around the Boston, Massachusetts, metro area. Furthermore, the sensor was placed in residential and industrial environments to show its usefulness for indoor and outdoor pollution measurements. Lastly, we show the feasibility of using the HCHO sensor (or a network of them) in long-term monitoring stations for hazardous air pollutants.

  9. Rapid and sensitive determination of beta-phenylethylamine in animal brains by high performance liquid chromatography with fluorometric detection.

    Science.gov (United States)

    Taga, C; Tsuji, M; Nakajima, T

    1989-05-01

    A reversed phase HPLC method with fluorometric detection for the analysis of beta-phenylethylamine has been developed using p-methoxyphenylethylamine as an internal standard. Two columns, containing 200 microL of Dowex 50-X8 and Amberlite CG-50 respectively, were used to prepare a fraction containing beta-phenylethylamine. The recoveries of beta-phenylethylamine and p-methoxyphenylethylamine were 53.9 +/- 9.4% and 68.1 +/- 12.4%, respectively, and elution profile of p-methoxyphenylethylamine was sufficiently well correlated with that of beta-phenylethylamine. Regional distributions of beta-phenylethylamine in rat and mouse brains were determined. The highest concentrations were found in hypothalamus and hippocampus in both animals.

  10. Photometric and fluorometric continuous kinetic assay of acid phosphatases with new substrates possessing longwave absorption and emission maxima.

    Science.gov (United States)

    Koller, E; Wolfbeis, O S

    1984-11-15

    A direct and continuous kinetic method for the photometric and fluorometric determination of various acid phosphatases is described. It is based on new coumarin-derived phosphates, which after enzymatic hydrolysis undergo dissociation to form intensely colored and strongly fluorescent phenolate anions. The latter have absorption maxima ranging from 385 to 505 nm, and fluorescence maxima between 470 and 595 nm. The new substrates were compared with respect to their rate of enzymatic hydrolysis, optimum pH, and detection limits of acid phosphatase from potato and wheat germ. Detection limits of 0.001 unit/ml were found by photometry, and as low as 0.00006 unit/ml by fluorometry. The principal advantages of the new substrates over existing ones are longwave absorptions and emissions, large Stokes shifts, and the low pKa values of the corresponding phenols, thus allowing a direct and continuous assay of acid phosphatase even in weakly acidic solutions.

  11. New LASER fluorometric HPLC detection for ortho-tyrosine in gamma-irradiated phenylalanine solution and pork

    International Nuclear Information System (INIS)

    Miyahara, Makoto; Toyoda, Masatake; Saito, Yukio; Nagasawa, Taeko; Izumi, Keiko; Kitamura, Mayumi

    1999-01-01

    New analytical procedure for o-tyrosine was studied to investigate effects of gamma irradiation on aqueous phenylalanine solution and pork. The process includes extraction and hydrolysis of protein, derivatization of the free amino acid by fluororeagent, and finally separation and detection by LASER fluorometric HPLC. The detection limit was 25ng. To study how the procedure works, irradiated phenylalanine solution and pork were analyzed. The samples were irradiated at doses up to 10 kGy at room temperature. Three tyrosine isomers were detected in phenylalanine solution, and 2 isomers (o-and p-tyrosine) were found in pork. Dose response was found in the formation of the isomers both in phenylalanine solution and in pork. O-tyrosine peak obtained from irradiated pork was separated from interference successfully. Those findings illustrate the procedure may be applicable to detection of irradiated food. (author)

  12. Laser-based gluing of diamond-tipped saw blades

    Science.gov (United States)

    Hennigs, Christian; Lahdo, Rabi; Springer, André; Kaierle, Stefan; Hustedt, Michael; Brand, Helmut; Wloka, Richard; Zobel, Frank; Dültgen, Peter

    2016-03-01

    To process natural stone such as marble or granite, saw blades equipped with wear-resistant diamond grinding segments are used, typically joined to the blade by brazing. In case of damage or wear, they must be exchanged. Due to the large energy input during thermal loosening and subsequent brazing, the repair causes extended heat-affected zones with serious microstructure changes, resulting in shape distortions and disadvantageous stress distributions. Consequently, axial run-out deviations and cutting losses increase. In this work, a new near-infrared laser-based process chain is presented to overcome the deficits of conventional brazing-based repair of diamond-tipped steel saw blades. Thus, additional tensioning and straightening steps can be avoided. The process chain starts with thermal debonding of the worn grinding segments, using a continuous-wave laser to heat the segments gently and to exceed the adhesive's decomposition temperature. Afterwards, short-pulsed laser radiation removes remaining adhesive from the blade in order to achieve clean joining surfaces. The third step is roughening and activation of the joining surfaces, again using short-pulsed laser radiation. Finally, the grinding segments are glued onto the blade with a defined adhesive layer, using continuous-wave laser radiation. Here, the adhesive is heated to its curing temperature by irradiating the respective grinding segment, ensuring minimal thermal influence on the blade. For demonstration, a prototype unit was constructed to perform the different steps of the process chain on-site at the saw-blade user's facilities. This unit was used to re-equip a saw blade with a complete set of grinding segments. This saw blade was used successfully to cut different materials, amongst others granite.

  13. Laser-based analytical monitoring in nuclear-fuel processing plants

    International Nuclear Information System (INIS)

    Hohimer, J.P.

    1978-09-01

    The use of laser-based analytical methods in nuclear-fuel processing plants is considered. The species and locations for accountability, process control, and effluent control measurements in the Coprocessing, Thorex, and reference Purex fuel processing operations are identified and the conventional analytical methods used for these measurements are summarized. The laser analytical methods based upon Raman, absorption, fluorescence, and nonlinear spectroscopy are reviewed and evaluated for their use in fuel processing plants. After a comparison of the capabilities of the laser-based and conventional analytical methods, the promising areas of application of the laser-based methods in fuel processing plants are identified

  14. New developments in laser-based photoemission spectroscopy and its scientific applications: a key issues review

    Science.gov (United States)

    Zhou, Xingjiang; He, Shaolong; Liu, Guodong; Zhao, Lin; Yu, Li; Zhang, Wentao

    2018-06-01

    The significant progress in angle-resolved photoemission spectroscopy (ARPES) in last three decades has elevated it from a traditional band mapping tool to a precise probe of many-body interactions and dynamics of quasiparticles in complex quantum systems. The recent developments of deep ultraviolet (DUV, including ultraviolet and vacuum ultraviolet) laser-based ARPES have further pushed this technique to a new level. In this paper, we review some latest developments in DUV laser-based photoemission systems, including the super-high energy and momentum resolution ARPES, the spin-resolved ARPES, the time-of-flight ARPES, and the time-resolved ARPES. We also highlight some scientific applications in the study of electronic structure in unconventional superconductors and topological materials using these state-of-the-art DUV laser-based ARPES. Finally we provide our perspectives on the future directions in the development of laser-based photoemission systems.

  15. A Laser-Based Diagnostic Suite for Hypersonic Test Facilities, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR effort, Los Gatos Research (LGR) proposes to develop a suite of laser-based diagnostics for the study of reactive and non-reactive hypersonic flows....

  16. Inclusion of fluorophores in cyclodextrins: a closer look at the fluorometric determination of association constants by linear and nonlinear fitting procedures

    Science.gov (United States)

    Hutterer, Rudi

    2018-01-01

    The author discusses methods for the fluorometric determination of affinity constants by linear and nonlinear fitting methods. This is outlined in particular for the interaction between cyclodextrins and several anesthetic drugs including benzocaine. Special emphasis is given to the limitations of certain fits, and the impact of such studies on enzyme-substrate interactions are demonstrated. Both the experimental part and methods of analysis are well suited for students in an advanced lab.

  17. Supersymmetric dark matter: Indirect detection

    International Nuclear Information System (INIS)

    Bergstroem, L.

    2000-01-01

    Dark matter detection experiments are improving to the point where they can detect or restrict the primary particle physics candidates for non baryonic dark matter. The methods for detection are usually categorized as direct, i.e., searching for signals caused by passage of dark matter particles in terrestrial detectors, or indirect. Indirect detection methods include searching for antimatter and gamma rays, in particular gamma ray lines, in cosmic rays and high-energy neutrinos from the centre of the Earth or Sun caused by accretion and annihilation of dark matter particles. A review is given of recent progress in indirect detection, both on the theoretical and experimental side

  18. The Complexity of Indirect Translation

    DEFF Research Database (Denmark)

    Wenjie, L. I.

    2017-01-01

    its complex nature, and thus determined that many facets of ITr remain to be studied. The present article will try to encompass the complexity of ITr by looking into the reasons for translating indirectly, the challenge of finding out mediating texts (MTs), indirectness in both translation...... of which have been translated and interpreted indirectly through major languages like English, will be employed as examples. Hopefully, this study will offer more insights into the nature of translation as a social activity and raise further interests in studying translation as a complex phenomenon....

  19. A simplified indirect bonding technique

    Directory of Open Access Journals (Sweden)

    Radha Katiyar

    2014-01-01

    Full Text Available With the advent of lingual orthodontics, indirect bonding technique has become an integral part of practice. It involves placement of brackets initially on the models and then their transfer to teeth with the help of transfer trays. Problems encountered with current indirect bonding techniques used are (1 the possibility of adhesive flash remaining around the base of the brackets which requires removal (2 longer time required for the adhesive to gain enough bond strength for secure tray removal. The new simplified indirect bonding technique presented here overcomes both these problems.

  20. Constraining atmospheric ammonia emissions through new observations with an open-path, laser-based sensor

    Science.gov (United States)

    Sun, Kang

    As the third most abundant nitrogen species in the atmosphere, ammonia (NH3) is a key component of the global nitrogen cycle. Since the industrial revolution, humans have more than doubled the emissions of NH3 to the atmosphere by industrial nitrogen fixation, revolutionizing agricultural practices, and burning fossil fuels. NH3 is a major precursor to fine particulate matter (PM2.5), which has adverse impacts on air quality and human health. The direct and indirect aerosol radiative forcings currently constitute the largest uncertainties for future climate change predictions. Gas and particle phase NH3 eventually deposits back to the Earth's surface as reactive nitrogen, leading to the exceedance of ecosystem critical loads and perturbation of ecosystem productivity. Large uncertainties still remain in estimating the magnitude and spatiotemporal patterns of NH3 emissions from all sources and over a range of scales. These uncertainties in emissions also propagate to the deposition of reactive nitrogen. To improve our understanding of NH3 emissions, observational constraints are needed from local to global scales. The first part of this thesis is to provide quality-controlled, reliable NH3 measurements in the field using an open-path, quantum cascade laser-based NH3 sensor. As the second and third part of my research, NH3 emissions were quantified from a cattle feedlot using eddy covariance (EC) flux measurements, and the similarities between NH3 turbulent fluxes and those of other scalars (temperature, water vapor, and CO2) were investigated. The fourth part involves applying a mobile laboratory equipped with the open-path NH3 sensor and other important chemical/meteorological measurements to quantify fleet-integrated NH3 emissions from on-road vehicles. In the fifth part, the on-road measurements were extended to multiple major urban areas in both the US and China in the context of five observation campaigns. The results significantly improved current urban NH3

  1. The logic of indirect speech

    Science.gov (United States)

    Pinker, Steven; Nowak, Martin A.; Lee, James J.

    2008-01-01

    When people speak, they often insinuate their intent indirectly rather than stating it as a bald proposition. Examples include sexual come-ons, veiled threats, polite requests, and concealed bribes. We propose a three-part theory of indirect speech, based on the idea that human communication involves a mixture of cooperation and conflict. First, indirect requests allow for plausible deniability, in which a cooperative listener can accept the request, but an uncooperative one cannot react adversarially to it. This intuition is supported by a game-theoretic model that predicts the costs and benefits to a speaker of direct and indirect requests. Second, language has two functions: to convey information and to negotiate the type of relationship holding between speaker and hearer (in particular, dominance, communality, or reciprocity). The emotional costs of a mismatch in the assumed relationship type can create a need for plausible deniability and, thereby, select for indirectness even when there are no tangible costs. Third, people perceive language as a digital medium, which allows a sentence to generate common knowledge, to propagate a message with high fidelity, and to serve as a reference point in coordination games. This feature makes an indirect request qualitatively different from a direct one even when the speaker and listener can infer each other's intentions with high confidence. PMID:18199841

  2. Size-controlled sensitivity and selectivity for the fluorometric detection of Ag+ by homocysteine capped CdTe quantum dots

    International Nuclear Information System (INIS)

    Jiao, Hangzhou; Liang, Zhenhua; Peng, Guihua; Zhang, Ling; Lin, Hengwei

    2014-01-01

    We have synthesized water dispersible CdTe quantum dots (QDs) in different sizes and with various capping reagents, and have studied the effects of their size on the sensitivity and selectivity in the fluorometric determination of metal ions, particularly of silver(I). It is found that an increase in the particle size of homocysteine-capped CdTe QDs from 1.7 nm to 3.3 nm and to 3.7 nm enhances both the sensitivity and selectivity of the determination of Ag(I) to give an ultimate limit of detection as low as 8.3 nM. This effect can partially be explained by the better passivation of surface traps on smaller sized QDs via adsorption of Ag(I), thereby decreasing the apparent detection efficiency. In addition, the presence of CdS in the CdTe QDs is likely to play a role. The study demonstrates that an improvement in sensing performance is accomplished by using QDs of fine-tuned particle sizes. Such effects are likely also to occur with other QD-based optical probes. (author)

  3. A new BODIPY-derived ratiometric senor with internal charge transfer (ICT) effect: colorimetric/fluorometric sensing of Ag.

    Science.gov (United States)

    Zhang, Changli; Han, Zhong; Wang, Mengjia; Yang, Zhenghao; Ran, Xueqin; He, Weijiang

    2018-02-13

    With a 4-aminostyryl group introduced at its 3-position, a BODIPY BDP-ODTAC was derived as a new ratiometric sensor for Ag + by modifying 4-amino group as a Ag + chelator, 1-oxa-4,10-dithia-7-azacyclododecane (ODTAC). In addition to the specific Ag + -induced hypsochromic absorption shift from 606 to 562 nm, this sensor demonstrated an excitation shift from 600 to 560 nm due to the internal charge transfer (ICT) effect endowed by the introduced α-4-aminostyryl group. The Ag + -induced recovery and enhancement of the intrinsic local emission band was also observed. The different sensing behavior of ODTAC-BDP with chelator ODTAC substituting on the meso-phenyl group infers that the ratiometric sensing behavior of BDP-ODTAC is correlated to the amino group in ODTAC acting as the electron donor for the ICT effect. With high Ag + selectivity over interfering cations such as Hg 2+ and Pb 2+ , BDP-ODTAC displays a fluorometric limit of detection (LOD) of ∼17 nM (∼0.002 ppm), which is distinctly lower than EPA and WHO standards for drinking water (500 nM, ∼0.055 ppm). Moreover, the BDP-ODTAC-doped PVC film shows the Ag + sensitivity of 1 ppm with a color switch from blue to purple, providing this sensor the ability to determine Ag + in totally aqueous solution sensitively via naked-eye detection.

  4. Determination of ochratoxin A in wine by means of immunoaffinity and aminopropyl solid-phase column cleanup and fluorometric detection.

    Science.gov (United States)

    Longobardi, Francesco; Iacovelli, Vito; Catucci, Lucia; Panzarini, Giuseppe; Pascale, Michelangelo; Visconti, Angelo; Agostiano, Angela

    2013-02-27

    A new analytical method for the determination of ochratoxin A (OTA) in red wine has been developed by using a double-extract cleanup and a fluorometric measurement after spectral deconvolution. Wine samples were diluted with a solution containing 1% polyethylene glycol and 5% sodium hydrogencarbonate, filtered, and purified by immunoaffinity and aminopropyl solid-phase column. OTA contents in the purified extract were determined by a spectrofluorometer (excitation wavelength, 330 nm; emission wavelength, 470 nm) after deconvolution of fluorescence spectra. Average recoveries from wine samples spiked with OTA at levels ranging from 0.5 to 3.0 ng/mL were 94.5-105.4% with relative standard deviations (RSD) of <15% (n = 4). The limit of detection (LOD) was 0.2 ng/mL, and the total time of analysis was 30 min. The developed method was tested on 18 red wine samples (naturally contaminated and spiked with OTA at levels ranging from 0.4 to 3.0 ng/mL) and compared with AOAC Official Method 2001.01, based on immunoaffinity column cleanup and HPLC with fluorescence detector. A good correlation (r(2) = 0.9765) was observed between OTA levels obtained with the two methods, highlighting the reliability of the proposed method, the main advantage of which is the simple OTA determination by a benchtop fluorometer with evident reductions of cost and time of analysis.

  5. Cytotoxic drug sensitivity testing of tumor cells from patients with ovarian carcinoma using the fluorometric microculture cytotoxicity assay (FMCA).

    Science.gov (United States)

    Csoka, K; Larsson, R; Tholander, B; Gerdin, E; de la Torre, M; Nygren, P

    1994-08-01

    The automated fluorometric microculture cytotoxicity assay (FMCA) is based on the measurement of fluorescence generated from cellular hydrolysis of fluorescein diacetate (FDA) to fluorescein by viable cells after a 72-hr culture period in microtiter plates. The FMCA was adopted for chemosensitivity testing of tumor cells from patients with ovarian carcinoma. Thirty-seven samples of solid tumors and malignant effusions were obtained from 35 patients at diagnosis or relapse. Tumor cells from solid samples and effusions were prepared by enzymatic digestion and centrifugation, respectively, followed by Percoll or Ficoll purification. The fluorescence was proportional to the number of cells/well and considerably higher in tumor cells than in contaminating normal cells. The effect of up to 19 cytotoxic drugs was successfully assessed in 70% of the samples and there was a good correlation between drug sensitivity data reported by the FMCA and the DiSC assay performed in parallel. The overall drug sensitivity pattern in vitro corresponded well to the clinical experience. The effect of cisplatin varied considerably between patients and resistance was found also in cases not previously exposed to cytotoxic drugs. The FMCA is a rapid and simple method that seems to report clinically relevant cytotoxic drug sensitivity data in ovarian carcinomas. In the future, this method may contribute to optimizing chemotherapy by assisting in individualized drug selection and new drug development.

  6. In vitro determination of cytotoxic drug response in ovarian carcinoma using the fluorometric microculture cytotoxicity assay (FMCA).

    Science.gov (United States)

    Csóka, K; Tholander, B; Gerdin, E; de la Torre, M; Larsson, R; Nygren, P

    1997-09-17

    The fluorometric microculture cytotoxicity assay (FMCA), a short-term in vitro assay based on the concept of total tumor cell kill, was used for testing the cytotoxic drug sensitivity of tumor cells from patients with ovarian carcinoma. A total of 125 fresh specimens was obtained, 98 (78%) of which were analyzed successfully. Data from 45 patients were available for clinical correlations. The FMCA appeared to yield clinically relevant cytotoxic drug sensitivity data for ovarian carcinoma as indicated by a comparison with tumor samples obtained from patients with non-Hodgkin's lymphoma or kidney carcinoma. Considering the most active single agent in vitro actually given in vivo, and using the median drug activity among all ovarian carcinoma samples as a cut-off, the sensitivity of the assay and its specificity were 75 and 52%, respectively. Cross-resistance in vitro was frequently observed between standard drugs but not between standard drugs and Taxol. Ten percent of the specimens showed an extreme resistance for at least 4 of 6 of the drugs investigated.

  7. In vitro testing of chemotherapeutic drug combinations in acute myelocytic leukaemia using the fluorometric microculture cytotoxicity assay (FMCA).

    Science.gov (United States)

    Larsson, R; Fridborg, H; Kristensen, J; Sundström, C; Nygren, P

    1993-05-01

    The fluorometric microculture cytotoxicity assay (FMCA) was employed for analysing the effect of different chemotherapeutic drug combinations and their single constituents in 44 cases of acute myelocytic leukaemia (AML). A large heterogeneity with respect to cell kill was observed for all combinations tested, the interactions ranging from antagonistic to synergistic in terms of the multiplicative concept for drug interactions. However, an 'additive' model provided a significantly better fit of the data compared to the effect of the most active single agent of the combination (Dmax) for several common antileukaemic drug combinations. When the two interaction models were related to treatment outcome 38% of the non-responders showed preference for the additive model whereas the corresponding figure for responders was 80%. Overall, in 248 of 290 (85%) tests performed with drug combinations, there was an agreement between the effect of the combination and that of the most active single component. Direct comparison of Dmax and the combination for correlation with clinical outcome demonstrated only minor differences in the ability to predict drug resistance. The results show that FMCA appear to report drug interactions in samples from patients with AML in accordance with clinical experience. Furthermore, testing single agents as a substitute for drug combinations may be adequate for detection of clinical drug resistance to combination therapy in AML.

  8. A rapid fluorometric method for semiautomated determination of cytotoxicity and cellular proliferation of human tumor cell lines in microculture.

    Science.gov (United States)

    Larsson, R; Nygren, P

    1989-01-01

    A fluorometric method for the determination of cellular growth and cytotoxicity of human tumor cell lines in 96-well microculture plates is described. The assay is based on the combined use of the DNA-binding dye Hoechst 33342 and the fluorogenic substrate fluorescein diacetate (FDA). Hoechst 33342 undergoes a dramatic enhancement of fluorescence when specifically intercalated with cellular DNA, whereas the FDA fluorescence is dependent on cellular hydrolysis of the non-fluorescent substrate into its fluorescent product. Fluorescence from both dyes was linearly related to the density of freshly seeded cells (6 x 10(3)-1 x 10(5)/well) and correlated well with physical cell count of cells under normal culture conditions as well as in response to the vinca alkaloid vincristine. However, the amount of FDA fluorescence produces and retained by the cultures was clearly dependent on the fraction of intact and viable cells, whereas the fluorescence reported by Hoechst 33342 was not. The assay was found to be simple, reliable and many samples could be analysed in a short period of time with minimal waste of cells and biological reagents. Apart from giving an estimate of cell density, the protocol described also provides a separate index of viability which in certain situations may be of importance for distinguishing between cytocidal and cytostatic drug actions. The method may be well suited for several applications, including the large scale screening for antitumor activity of compounds with potential cytocidal or cytostatic actions.

  9. Laboratory determination of chemotherapeutic drug resistance in tumor cells from patients with leukemia, using a fluorometric microculture cytotoxicity assay (FMCA).

    Science.gov (United States)

    Larsson, R; Kristensen, J; Sandberg, C; Nygren, P

    1992-01-21

    An automated fluorometric microculture cytotoxicity assay (FMCA) based on the measurement of fluorescence generated from cellular hydrolysis of fluorescein diacetate (FDA) to fluorescein was employed for chemotherapeutic-drug-sensitivity testing of tumor-cell suspensions from patients with leukemia. Fluorescence was linearly related to cell number, and reproducible measurements of drug sensitivity could be performed using fresh or cryopreserved leukemia cells. A marked heterogeneity with respect to chemotherapeutic drug sensitivity was observed for a panel of cytotoxic drugs tested in 43 samples from 35 patients with treated or untreated acute and chronic leukemia. For samples obtained from patients with chronic lymphocytic and acute myelocytic leukemia, sensitivity profiles for standard drugs corresponded to known clinical activity and the assay detected primary and acquired drug resistance. Individual in vitro/in vivo correlations indicated high specificity with respect to the identification of drug resistance. The results suggest that the FMCA may be a simple and rapid method for in vivo-representative determinations of chemotherapeutic drug resistance in tumor cells obtained from patients with leukemia.

  10. [Determination of atracurium and laudanosine in dog plasma during cardiopulmonary bypass by high performance liquid chromatography with fluorometric detection].

    Science.gov (United States)

    Yang, Yingying; Chen, Mei; Kuang, Yushan; Ye, Liming; Zhang, Wensheng

    2013-06-01

    A high performance liquid chromatographic method coupled with fluorometric detection has been developed for the determination of atracurium and its major metabolite laudanosine in dog plasma. The separation of atracurium and laudanosine was performed on an Agilent Eclipse Plus C18 column, and the mobile phase consisted of 0.03 mol/L dipotassium hydrogen phosphate and acetonitrile (72: 28, v/v) at a flow rate of 1.0 mL/min. Verapamil was used as the internal standard. The sample was extracted by dichloromethane, concentrated and dissolved in the mobile phase. The detection is performed at 240 nm for excitation and 320 nm for emission. The results showed that the linear concentration ranges of the calibration curve were 25 - 5 000 microg/L for atracurium (r = 0.999 0), and 25 - 6 000 microg/L for laudanosine (r = 0.9984). The recoveries were 92.1% - 109.5%. The limits of detection were 3 microg/L for atracurium and 1 microg/L for laudanosine. The RSDs of intra-day and inter-day were less than 10%. The stability tests under various conditions have been performed. The method is specific, sensitive and accurate in the determination of atracurium and laudanosine, and also can be used for the pharmacokinetic investigations of atracurium and laudanosine in plasma.

  11. Laser-based diagnostics on NO in a diesel engine

    International Nuclear Information System (INIS)

    Brugman, T.M.

    1999-01-01

    The non-intrusive two-dimensional detection of nitric oxide (NO) in the cylinder of a diesel engine by means of laser-induced fluorescence (LIF) is the central theme of this thesis. Chapter 1 provides a general introduction including a brief discussion of the underlying environmental considerations as well as an overview of the laser-based imaging diagnostics in i.c. engines as reported in the literature. In the same chapter the LIF spectroscopy of NO is discussed in detail and the dependence of the LIF signal to several parameters is studied on the basis of a two-level rate equation model. This chapter concludes with an overview of the imaging techniques used in the experiments discussed in this thesis. The principal components of the experimental setup are described in great detail in chapter 2. Some of the issues discussed there have turned out to be crucial for the success of the experiments as reported in the subsequent chapters. In chapter 3 the results of the first imaging experiments in the idling engine are reported for two different fuels: n-heptane and standard diesel fuel. Besides the in-cylinder NO fluorescence distributions at various crank angles presented in this chapter, excitation spectra recorded from in-cylinder NO at atmospheric pressure using the respective fuels are also reported. In chapter 4 the detection method is further validated on the basis of a number of experiments in the standard-diesel -fuel -driven engine testing the various underlying assumptions. The sensitivity of the LIF signal to photo-chemically- induced effects possibly arising from the use of a high-power UV excimer laser, is investigated by means of a double-resonance experiment. The dependence of the LIF signal on the actual laser power is experimentally verified as well. The degree as to which saturation might occur at the in-cylinder laser intensities pertinent to this work, is estimated using data and relations found in the literature. Finally, in this chapter image

  12. Indirect Reciprocity; A Field Experiment.

    Science.gov (United States)

    van Apeldoorn, Jacobien; Schram, Arthur

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has been widely studied theoretically, the empirical evidence of indirect reciprocity has thus far been limited and based solely on behavior in laboratory experiments. We provide evidence from an online environment where members can repeatedly ask and offer services to each other, free of charge. For the purpose of this study we created several new member profiles, which differ only in terms of their serving history. We then sent out a large number of service requests to different members from all over the world. We observe that a service request is more likely to be rewarded for those with a profile history of offering the service (to third parties) in the past. This provides clear evidence of (downstream) indirect reciprocity. We find no support for upstream indirect reciprocity (in this case, rewarding the service request after having previously received the service from third parties), however. Our evidence of downstream indirect reciprocity cannot be attributed to reputational effects concerning one's trustworthiness as a service user.

  13. Indirect Reciprocity under Incomplete Observation

    Science.gov (United States)

    Nakamura, Mitsuhiro; Masuda, Naoki

    2011-01-01

    Indirect reciprocity, in which individuals help others with a good reputation but not those with a bad reputation, is a mechanism for cooperation in social dilemma situations when individuals do not repeatedly interact with the same partners. In a relatively large society where indirect reciprocity is relevant, individuals may not know each other's reputation even indirectly. Previous studies investigated the situations where individuals playing the game have to determine the action possibly without knowing others' reputations. Nevertheless, the possibility that observers of the game, who generate the reputation of the interacting players, assign reputations without complete information about them has been neglected. Because an individual acts as an interacting player and as an observer on different occasions if indirect reciprocity is endogenously sustained in a society, the incompleteness of information may affect either role. We examine the game of indirect reciprocity when the reputations of players are not necessarily known to observers and to interacting players. We find that the trustful discriminator, which cooperates with good and unknown players and defects against bad players, realizes cooperative societies under seven social norms. Among the seven social norms, three of the four suspicious norms under which cooperation (defection) to unknown players leads to a good (bad) reputation enable cooperation down to a relatively small observation probability. In contrast, the three trustful norms under which both cooperation and defection to unknown players lead to a good reputation are relatively efficient. PMID:21829335

  14. Metal monitoring for process control of laser-based coating removal

    Science.gov (United States)

    Fraser, Mark E.; Hunter, Amy J.; Panagiotou, Thomai; Davis, Steven J.; Freiwald, David A.

    1999-12-01

    Cost-effective and environmentally-sound means of paint and coatings removal is a problem spanning many government, commercial, industrial and municipal applications. For example, the Department of Energy is currently engaged in removing paint and other coatings from concrete and structural steel as part of decommissioning former nuclear processing facilities. Laser-based coatings removal is an attractive new technology for these applications as it promises to reduce the waste volume by up to 75 percent. To function more efficiently, however, the laser-based systems require some form of process control.

  15. Ultrafast, laser-based, x-ray science: the dawn of atomic-scale cinematography

    International Nuclear Information System (INIS)

    Barty, C.P.J.

    2000-01-01

    The characteristics of ultrafast chirped pulse amplification systems are reviewed. Application of ultrafast chirped pulse amplification to the generation of femtosecond, incoherent, 8-keV line radiation is outlined and the use of femtosecond laser-based, x-rays for novel time-resolved diffraction studies of crystalline dynamics with sub-picosecond temporal resolution and sub-picometer spatial resolution is reviewed in detail. Possible extensions of laser-based, x-ray technology and evaluation of alternative x-ray approaches for time-resolved studies of the atomic scale dynamics are given. (author)

  16. Welding technology transfer task/laser based weld joint tracking system for compressor girth welds

    Science.gov (United States)

    Looney, Alan

    1991-01-01

    Sensors to control and monitor welding operations are currently being developed at Marshall Space Flight Center. The laser based weld bead profiler/torch rotation sensor was modified to provide a weld joint tracking system for compressor girth welds. The tracking system features a precision laser based vision sensor, automated two-axis machine motion, and an industrial PC controller. The system benefits are elimination of weld repairs caused by joint tracking errors which reduces manufacturing costs and increases production output, simplification of tooling, and free costly manufacturing floor space.

  17. Ultrafast, laser-based, x-ray science: the dawn of atomic-scale cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Barty, C.P.J. [University of California, Department of Applied Mechanics and Engineering Science, Urey Hall, Mali Code 0339, San Diego, La Jolla, CA (United States)

    2000-03-01

    The characteristics of ultrafast chirped pulse amplification systems are reviewed. Application of ultrafast chirped pulse amplification to the generation of femtosecond, incoherent, 8-keV line radiation is outlined and the use of femtosecond laser-based, x-rays for novel time-resolved diffraction studies of crystalline dynamics with sub-picosecond temporal resolution and sub-picometer spatial resolution is reviewed in detail. Possible extensions of laser-based, x-ray technology and evaluation of alternative x-ray approaches for time-resolved studies of the atomic scale dynamics are given. (author)

  18. Indirect techniques in nuclear astrophysics

    International Nuclear Information System (INIS)

    Mukhamedzhanov, A.M.; Tribble, R.E.; Blokhintsev, L.D.; Cherubini, S.; Spitaleri, C.; Kroha, V.; Nunes, F.M.

    2005-01-01

    It is very difficult or often impossible to measure in the lab conditions nuclear cross sections at astrophysically relevant energies. That is why different indirect techniques are used to extract astrophysical information. In this talk different experimental possibilities to get astrophysical information using radioactive and stable beams will be addressed. 1. The asymptotic normalization coefficient (ANC) method. 2. Radiative neutron captures are determined by the spectroscopic factors (SP). A new experimental technique to determine the neutron SPs will be addressed. 3. 'Trojan Horse' is another unique indirect method, which allows one to extract the astrophysical factors for direct and resonant nuclear reactions at astrophysically relevant energies. (author)

  19. Superflux chlorophyll-a analysis: An assessment of variability in results introduced prior to fluorometric analysis. [chesapeake bay and shelf regions

    Science.gov (United States)

    Cibik, S. J.; Rutledge, C. K.; Robertson, C. N.

    1981-01-01

    Several experiments were undertaken to identify variability in results that came from procedural differences in the processing of chlorophyll samples prior to fluorometric analysis. T-tests on group means indicated that significant differences (alpha = 0.05) in phaeopigment a concentrations did result in samples not initially screened, but not in the chlorophyll a concentrations. Highly significant differences (alpha = 0.001) in group means were found in samples which were held in acetone after filtering as compared to unfiltered seawater samples held for the same period. No difference in results was found between the 24-hour extraction and samples which were processed immediately.

  20. Environmental effects of indirect subsidies

    International Nuclear Information System (INIS)

    Van Beers, C.P.; De Moor, A.P.G.; Van den Bergh, J.C.J.M.; Oosterhuis, F.H.

    2003-01-01

    The aim of the study on the title subject is to develop a transparent integrated method to determine and analyze the environmental impacts of indirect subsidies, applied in the sectors agriculture, energy, mobility, and tourism. From the results it appears that the hazardous effects of subsidies are big. Examples are milk, the regulating energy levy, and kerosene [nl

  1. Indirect searches for dark matter

    Indian Academy of Sciences (India)

    The current status of indirect searches for dark matter has been reviewed in a schematic way here. The main relevant experimental results of the recent years have been listed and the excitements and disappointments that their phenomenological interpretations in terms of almost-standard annihilating dark matter have ...

  2. Indirect methods in nuclear astrophysics

    International Nuclear Information System (INIS)

    Bertulani, C.A.; Shubhchintak; Mukhamedzhanov, A.; Kadyrov, A. S.; Kruppa, A.; Pang, D. Y.

    2016-01-01

    We discuss recent developments in indirect methods used in nuclear astrophysics to determine the capture cross sections and subsequent rates of various stellar burning processes, when it is difficult to perform the corresponding direct measurements. We discuss in brief, the basic concepts of Asymptotic Normalization Coefficients, the Trojan Horse Method, the Coulomb Dissociation Method, (d,p), and charge-exchange reactions. (paper)

  3. Indirect Reciprocity : A Field Experiment

    NARCIS (Netherlands)

    van Apeldoorn, J.; Schram, A.

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has

  4. Indirect reciprocity with optional interactions.

    Science.gov (United States)

    Ghang, Whan; Nowak, Martin A

    2015-01-21

    Indirect reciprocity is a mechanism for the evolution of cooperation that is relevant for prosocial behavior among humans. Indirect reciprocity means that my behavior towards you also depends on what you have done to others. Indirect reciprocity is associated with the evolution of social intelligence and human language. Most approaches to indirect reciprocity assume obligatory interactions, but here we explore optional interactions. In any one round a game between two players is offered. A cooperator accepts a game unless the reputation of the other player indicates a defector. For a game to take place, both players must accept. In a game between a cooperator and a defector, the reputation of the defector is revealed to all players with probability Q. After a sufficiently large number of rounds the identity of all defectors is known and cooperators are no longer exploited. The crucial condition for evolution of cooperation can be written as hQB>1, where h is the average number of rounds per person and B=(b/c)-1 specifies the benefit-to-cost ratio. We analyze both stochastic and deterministic evolutionary game dynamics. We study two extensions that deal with uncertainty: hesitation and malicious gossip. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Seam gap bridging of laser based processes for the welding of aluminium sheets for industrial applications

    NARCIS (Netherlands)

    Aalderink, B.J.; Aalderink, Benno; Pathiraj, B.; Aarts, Ronald G.K.M.

    2010-01-01

    Laser welding has a large potential for the production of tailor welded blanks in the automotive industry, due to the low heat input and deep penetration. However, due to the small laser spot and melt pool, laser-based welding processes in general have a low tolerance for seam gaps. In this paper,

  6. 77 FR 14838 - General Electric-Hitachi Global Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-13

    ... Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment Facility, Wilmington, North Carolina... a license to General Electric-Hitachi Global Laser Enrichment LLC (GLE or the applicant) to authorize construction of a laser-based uranium enrichment facility and possession and use of byproduct...

  7. Indirect taxation in the European Union

    OpenAIRE

    Ene, Sebastian; Micuda, Dan

    2007-01-01

    Indirect taxes are levied on the production and consumption of goods and services. They influence the retail price, and hence affect patterns of trade and consumption. Indirect taxes are ultimately paid by the final consumer. Sales and turnover taxes, excise duties and tariffs are the basic indirect taxes. In contrast with direct taxes, indirect taxes are seldom progressive. The principles for the levying of these taxes will be considered before the analysis of indirect taxes.

  8. Electronic Commerce and Indirect Taxation

    OpenAIRE

    Watanabe, Satoshi

    2001-01-01

    This paper considers the reason why indirect tax issues arise in the context of electronic commerce and discusses relevant issues. To do so, the paper presents a simple framework to understand and examine these issues in the international context. It also identifies common and different issues of the VAT system and the RST system. It demonstrates that an emerging solution proposed in the context of the VAT system can be affected with difficult problems that were regarded to be problems of the...

  9. Conventional and first derivative synchronous fluorometric determination of ethamsylate in pharmaceutical preparations and biological fluids. Application to stability studies.

    Science.gov (United States)

    Belal, Fathalla; El-Brashy, Amina; El-Enany, Nahed; Tolba, Manar

    2011-07-01

    Two simple, accurate and highly sensitive spectrofluorometric methods were developed for the determination of ethamsylate (ETM). Method I is based on measuring the native fluorescence of ethamsylate in water at 354 nm after excitation at 302 nm. The calibration plot was rectilinear over the range of 0.05-1 μg/mL for ETM with limits of detection and quantitation of 7.9 and 26 ng/mL, respectively. Method II involved synchronous and first derivative synchronous fluorometric methods for the simultaneous determination of ethamsylate (ETM) and hydroquinone (HQ) which is considered as an impurity and/or acidic degradation product. The synchronous fluorescence of both the drug and its impurity were measured in methanol at Δ λ of 40 nm. The peak amplitudes ((1)D) were estimated at 293.85 or 334.17 nm for ETM and at 309.05 nm for HQ. Good linearity was obtained for ETM over the ranges 0.1-1.4 μg/mL and 0.1-1.0 μg/mL at 293.85 and 334.17 nm, respectively. For HQ, the calibration plot was rectilinear over the range of 0.01-0.14 μg/mL at 309.05 nm. Limits of detection were 20, 2.01 ng/mL and limits of quantitation were 60, 6.7 ng/mL for ETM and HQ by method II, respectively. Both methods were successfully applied to commercial ampoules and tablets. The results were in good agreement with those obtained by the reference method. Method I was utilized to study the stability of ETM and its degradation kinetics using peroxide. The apparent first-order rate constant, half-life times and activation energy of the degradation process were calculated. Method I was further extended to the in-vitro and in-vivo determination of ETM in spiked and real plasma samples. The mean% recoveries were 99.57 ± 3.85 and 89.39 ± 5.93 for spiked and real human plasma, respectively. © Springer Science+Business Media, LLC 2011

  10. A cell-free fluorometric high-throughput screen for inhibitors of Rtt109-catalyzed histone acetylation.

    Directory of Open Access Journals (Sweden)

    Jayme L Dahlin

    Full Text Available The lysine acetyltransferase (KAT Rtt109 forms a complex with Vps75 and catalyzes the acetylation of histone H3 lysine 56 (H3K56ac in the Asf1-H3-H4 complex. Rtt109 and H3K56ac are vital for replication-coupled nucleosome assembly and genotoxic resistance in yeast and pathogenic fungal species such as Candida albicans. Remarkably, sequence homologs of Rtt109 are absent in humans. Therefore, inhibitors of Rtt109 are hypothesized as potential and minimally toxic antifungal agents. Herein, we report the development and optimization of a cell-free fluorometric high-throughput screen (HTS for small-molecule inhibitors of Rtt109-catalyzed histone acetylation. The KAT component of the assay consists of the yeast Rtt109-Vps75 complex, while the histone substrate complex consists of full-length Drosophila histone H3-H4 bound to yeast Asf1. Duplicated assay runs of the LOPAC demonstrated day-to-day and plate-to-plate reproducibility. Approximately 225,000 compounds were assayed in a 384-well plate format with an average Z' factor of 0.71. Based on a 3σ cut-off criterion, 1,587 actives (0.7% were identified in the primary screen. The assay method is capable of identifying previously reported KAT inhibitors such as garcinol. We also observed several prominent active classes of pan-assay interference compounds such as Mannich bases, catechols and p-hydroxyarylsulfonamides. The majority of the primary active compounds showed assay signal interference, though most assay artifacts can be efficiently removed by a series of straightforward counter-screens and orthogonal assays. Post-HTS triage demonstrated a comparatively small number of confirmed actives with IC50 values in the low micromolar range. This assay, which utilizes five label-free proteins involved in H3K56 acetylation in vivo, can in principle identify compounds that inhibit Rtt109-catalyzed H3K56 acetylation via different mechanisms. Compounds discovered via this assay or adaptations thereof could

  11. A Laser-based Ultrasonic Inspection System to Detect Micro Fatigue Cracks

    International Nuclear Information System (INIS)

    Park, Seung Kyu; Baik, Sung Hoon; Park, Moon Cheol; Lim, Chang Hwan; Cha, Hyung Ki

    2005-01-01

    Laser-based ultrasonic techniques have been established as a viable non-contact alternative to piezoelectric transducers for generating and receiving ultrasound. Laser-based ultrasonic inspection system provides a number of advantages over the conventional generation by piezoelectric transducers, especially a non-contact generation and detection of ultrasonic waves, high spatial scanning resolution, controllable narrow-band and wide-band spectrum, absolute measurements of the moving distance, use of fiber optics, and an ability to operate on curved and rough surfaces and at hard-to-access locations like a nuclear power plant. Ochiai and Miura used the laser-based ultrasound to detect micro fatigue cracks for the inspection of a material degradation in nuclear power plants. This widely applicable laser-based ultrasonic inspection system is comparatively expensive and provides low signal-to-noise ratio to measure ultrasound by using the laser interferometer. Many studies have been carried out to improve the measuring efficiency of the laser interferometer. One of the widely used laser interferometer types to measure the ultrasound is the Confocal Fabry-Perot Interferometer(CFPI). The measurement gain of the CFPI is slightly and continually varied according to the small change of the cavity length and the fluctuations of the measuring laser beam frequency with time. If we continually adjust the voltage of a PZT which is fixed to one of the interferometer mirrors, the optimum working point of the CFPI can be fixed. Though a static stabilizer can fix the gain of the CFPI where the CW laser beam is targeted at one position, it can not be used when the CW laser beam is scanned like a scanning laser source(SLS) technique. A dynamic stabilizer can be used for the scanning ultrasonic inspection system. A robust dynamic stabilizer is needed for an application to the industrial inspection fields. Kromine showed that the SLS technique is effective to detect small fatigue cracks

  12. Indirect detection of dark matter

    International Nuclear Information System (INIS)

    Pieri, L.

    2008-01-01

    In the Cold Dark Matter scenario, the Dark Matter particle candidate may be a Weakly Interacting Massive Particle (Wimp). Annihilation of two Wimps in local or cosmological structures would result in the production of a number of standard model particles such as photons, leptons and baryons which could be observed with the presently available or future experiments such as the Pamela or Glast satellites or the Cherenkov Telescopes. In this work we review the status-of-the-art of the theoretical and phenomenological studies about the possibility of indirect detection of signals coming from Wimp annihilation.

  13. Indirect detection of dark matter

    International Nuclear Information System (INIS)

    Carr, J; Lamanna, G; Lavalle, J

    2006-01-01

    This article is an experimental review of the status and prospects of indirect searches for dark matter. Experiments observe secondary particles such as positrons, antiprotons, antideuterons, gamma-rays and neutrinos which could originate from annihilations of dark matter particles in various locations in the galaxy. Data exist from some experiments which have been interpreted as hints of evidence for dark matter. These data and their interpretations are reviewed together with the new experiments which are planned to resolve the puzzles and make new measurements which could give unambiguous results

  14. Image-guided, Laser-based Fabrication of Vascular-derived Microfluidic Networks

    OpenAIRE

    Heintz, Keely A.; Mayerich, David; Slater, John H.

    2017-01-01

    This detailed protocol outlines the implementation of image-guided, laser-based hydrogel degradation for the fabrication of vascular-derived microfluidic networks embedded in PEGDA hydrogels. Here, we describe the creation of virtual masks that allow for image-guided laser control; the photopolymerization of a micromolded PEGDA hydrogel, suitable for microfluidic network fabrication and pressure head-driven flow; the setup and use of a commercially available laser scanning confocal microscope...

  15. Femtosecond laser based small incision lenticule extraction for moderate and high myopia

    DEFF Research Database (Denmark)

    Hjortdal, Jesper Østergaard; Asp, Sven; Ivarsen, Anders

    Femtosecond laser based small incision lenticule extraction for moderate and high myopia. Jesper Hjortdal, Sven Asp, Anders Ivarsen, Anders Vestergaard Department of Ophthalmology, Aarhus University Hospital, Denmark Purpose: ReLEx® smile is a new keratorefractive procedure whereby a stromal lent....... Refractive predictability, safety and patient satisfaction at 3 months seems equal to ReLEx flex and FS-LASIK. Optimizing laser energy settings and surgeon experience is important to minimize initial inferior results....

  16. Analysis of an atom laser based on the spatial control of the scattering length

    International Nuclear Information System (INIS)

    Carpentier, Alicia V.; Michinel, Humberto; Rodas-Verde, Maria I.; Perez-Garcia, Victor M.

    2006-01-01

    In this paper we analyze atom lasers based on the spatial modulation of the scattering length of a Bose-Einstein condensate. We demonstrate, through numerical simulations and approximate analytical methods, the controllable emission of matter-wave bursts and study the dependence of the process on the spatial shape of the scattering length along the axis of emission. We also study the role of an additional modulation of the scattering length in time

  17. Indirect Medical Education and Disproportionate Share Adj...

    Data.gov (United States)

    U.S. Department of Health & Human Services — Indirect Medical Education and Disproportionate Share Adjustments to Medicare Inpatient Payment Rates The indirect medical education (IME) and disproportionate share...

  18. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  19. Indirect costs of rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Filip Raciborski

    2015-12-01

    Full Text Available It is estimated that in Poland about 400,000 persons in general suffer from inflammatory joint diseases, including rheumatoid arthritis (RA. Epidemiological surveys documenting the frequency and disturbance of musculoskeletal disorders in the Polish population are few in number. Most of the estimations are based on epidemiological data from other countries (prevalence of 0.5–1%. According to the data of the National Health Fund in Poland 135,000–157,000 persons in total are treated because of rheumatoid arthritis per year [ICD10 (International Statistical Classification of Diseases and Related Health Problems: M05, M06]. In the case of this group of diseases indirect costs significantly outweigh the direct costs. Indirect costs increase together with activity level of the disease. The cost analysis of productivity loss of RA patients indicates that sickness absenteeism and informal care are the most burdensome. At the national level it amounts in total from 1.2 billion to 2.8 billion PLN per year, depending on the method of analysis. These costs could be significantly reduced through early diagnosis and introduction of effective treatment.

  20. Do infants detect indirect reciprocity?

    Science.gov (United States)

    Meristo, Marek; Surian, Luca

    2013-10-01

    In social interactions involving indirect reciprocity, agent A acts prosocially towards B and this prompts C to act prosocially towards A. This happens because A's actions enhanced its reputation in the eyes of third parties. Indirect reciprocity may have been of central importance in the evolution of morality as one of the major mechanisms leading to the selection of helping and fair attitudes. Here we show that 10-month-old infants expect third parties to act positively towards fair donors who have distributed attractive resources equally between two recipients, rather than toward unfair donors who made unequal distributions. Infants' responses were dependent on the reciprocator's perceptual exposure to previous relevant events: they expected the reciprocator to reward the fair donor only when it had seen the distributive actions performed by the donors. We propose that infants were able to generate evaluations of agents that were based on the fairness of their distributive actions and to generate expectations about the social preferences of informed third parties. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Indirect reciprocity with trinary reputations.

    Science.gov (United States)

    Tanabe, Shoma; Suzuki, Hideyuki; Masuda, Naoki

    2013-01-21

    Indirect reciprocity is a reputation-based mechanism for cooperation in social dilemma situations when individuals do not repeatedly meet. The conditions under which cooperation based on indirect reciprocity occurs have been examined in great details. Most previous theoretical analysis assumed for mathematical tractability that an individual possesses a binary reputation value, i.e., good or bad, which depends on their past actions and other factors. However, in real situations, reputations of individuals may be multiple valued. Another puzzling discrepancy between the theory and experiments is the status of the so-called image scoring, in which cooperation and defection are judged to be good and bad, respectively, independent of other factors. Such an assessment rule is found in behavioral experiments, whereas it is known to be unstable in theory. In the present study, we fill both gaps by analyzing a trinary reputation model. By an exhaustive search, we identify all the cooperative and stable equilibria composed of a homogeneous population or a heterogeneous population containing two types of players. Some results derived for the trinary reputation model are direct extensions of those for the binary model. However, we find that the trinary model allows cooperation under image scoring under some mild conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Indirect Cost Reimbursement: An Industrial View.

    Science.gov (United States)

    Bolton, Robert

    1987-01-01

    The meaning of indirect costs in an industrial environment is discussed. Other factors considered are corporate policies; nature of work being supported; the uniqueness of the work; who is doing the negotiating for industry; and indirect rates. Suggestions are offered for approaches to indirect cost reimbursement. (Author/MLW)

  3. Language shifts in free indirect discourse

    NARCIS (Netherlands)

    Maier, Emar

    Free indirect discourse is a way of reporting what a protagonist thinks or says that is distinct from both direct and indirect discourse. In particular, while pronouns and tenses are presented from the narrator's perspective, as in indirect discourse, other indexical and expressive elements reflect

  4. Directe en indirecte werknemersparticipatie in Europa

    NARCIS (Netherlands)

    van Houten, Gijs; Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo; Vermeylen, Greet

    2016-01-01

    This study looks at different forms of direct and indirect employee participation in the EU. The research questions are: (1) which forms of direct and indirect employee participation can we distinguish?; (2) to what extent do forms of direct and indirect employee participation coincide within

  5. Fluorometric Analysis of Riboflavin.

    Science.gov (United States)

    Hu, Ji-Yue; And Others

    1990-01-01

    Described is the use of fluorometry in an experiment where the fluorescence of riboflavin is specifically quenched when titrated with riboflavin-binding protein. The amount of riboflavin, required by all organisms, in an unknown solution and the dissociation constant of the vitamin-protein complex can be determined using this method. (KR)

  6. Preparation of electrodes on cfrp composites with low contact resistance comprising laser-based surface pre-treatment

    KAUST Repository

    Almuhammadi, Khaled Hamdan; Lubineau, Gilles; Alfano, Marco Francesco; Buttner, Ulrich

    2016-01-01

    Various examples are provided related to the preparation of electrodes on carbon fiber reinforced polymer (CFRP) composites with low contact resistance. Laser-based surface preparation can be used for bonding to CFRP composites. In one example, a

  7. Fluorometric titration approach for calibration of quantity of binding site of purified monoclonal antibody recognizing epitope/hapten nonfluorescent at 340 nm.

    Science.gov (United States)

    Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei

    2014-06-17

    A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.

  8. High-brightness electron beam evolution following laser-based cleaning of a photocathode

    Directory of Open Access Journals (Sweden)

    F. Zhou

    2012-09-01

    Full Text Available Laser-based techniques have been widely used for cleaning metal photocathodes to increase quantum efficiency (QE. However, the impact of laser cleaning on cathode uniformity and thereby on electron beam quality are less understood. We are evaluating whether this technique can be applied to revive photocathodes used for high-brightness electron sources in advanced x-ray free-electron laser (FEL facilities, such as the Linac Coherent Light Source (LCLS at the SLAC National Accelerator Laboratory. The laser-based cleaning was applied to two separate areas of the current LCLS photocathode on July 4 and July 26, 2011, respectively. The QE was increased by 8–10 times upon the laser cleaning. Since the cleaning, routine operation has exhibited a slow evolution of the QE improvement and comparatively rapid improvement of transverse emittance, with a factor of 3 QE enhancement over five months, and a significant emittance improvement over the initial 2–3 weeks following the cleaning. Currently, the QE of the LCLS photocathode is holding constant at about 1.2×10^{-4}, with a normalized injector emittance of about 0.3  μm for a 150-pC bunch charge. With the proper procedures, the laser-cleaning technique appears to be a viable tool to revive the LCLS photocathode. We present observations and analyses for the QE and emittance evolution in time following the laser-based cleaning of the LCLS photocathode, and comparison to the previous studies, the measured thermal emittance versus the QE and comparison to the theoretical model.

  9. Past, Present and Future Aspects of Laser-Based Synchronization at FLASH

    OpenAIRE

    Schulz, Sebastian; Bousonville, Michael; Steffen, Bernd; Sydlo, Cezary; Zummack, Falco; Kozak, Tomasz; Predki, Pawel; Kuhl, Alexander; Czwalinna, Marie Kristin; Felber, Matthias; Heuer, Michael; Lamb, Thorsten; Mueller, Jost; Peier, Peter; Ruzin, Sergej

    2013-01-01

    Free-electron lasers, like FLASH and the upcoming European XFEL, are capable of producing XUV and X-ray pulses of a few femtoseconds duration. For time-resolved pump-probe experiments and the externally seeded operation mode it is crucial not only to stabilize the arrival time of the electron bunches, but also to achieve a synchronization accuracy of external lasers on the same timescale. This can only be realized with a laser-based synchronization infrastructure. At FLASH, a periodic femtose...

  10. A High Precision Laser-Based Autofocus Method Using Biased Image Plane for Microscopy

    Directory of Open Access Journals (Sweden)

    Chao-Chen Gu

    2018-01-01

    Full Text Available This study designs and accomplishes a high precision and robust laser-based autofocusing system, in which a biased image plane is applied. In accordance to the designed optics, a cluster-based circle fitting algorithm is proposed to calculate the radius of the detecting spot from the reflected laser beam as an essential factor to obtain the defocus value. The experiment conduct on the experiment device achieved novel performance of high precision and robustness. Furthermore, the low demand of assembly accuracy makes the proposed method a low-cost and realizable solution for autofocusing technique.

  11. Algal Biomass Analysis by Laser-Based Analytical Techniques—A Review

    Directory of Open Access Journals (Sweden)

    Pavel Pořízka

    2014-09-01

    Full Text Available Algal biomass that is represented mainly by commercially grown algal strains has recently found many potential applications in various fields of interest. Its utilization has been found advantageous in the fields of bioremediation, biofuel production and the food industry. This paper reviews recent developments in the analysis of algal biomass with the main focus on the Laser-Induced Breakdown Spectroscopy, Raman spectroscopy, and partly Laser-Ablation Inductively Coupled Plasma techniques. The advantages of the selected laser-based analytical techniques are revealed and their fields of use are discussed in detail.

  12. Single-mode fiber laser based on core-cladding mode conversion.

    Science.gov (United States)

    Suzuki, Shigeru; Schülzgen, Axel; Peyghambarian, N

    2008-02-15

    A single-mode fiber laser based on an intracavity core-cladding mode conversion is demonstrated. The fiber laser consists of an Er-doped active fiber and two fiber Bragg gratings. One Bragg grating is a core-cladding mode converter, and the other Bragg grating is a narrowband high reflector that selects the lasing wavelength. Coupling a single core mode and a single cladding mode by the grating mode converter, the laser operates as a hybrid single-mode laser. This approach for designing a laser cavity provides a much larger mode area than conventional large-mode-area step-index fibers.

  13. Laser-based secondary neutral mass spectroscopy: Useful yield and sensitivity

    International Nuclear Information System (INIS)

    Young, C.E.; Pellin, M.J.; Calaway, W.F.; Joergensen, B.; Schweitzer, E.L.; Gruen, D.M.

    1986-01-01

    A variety of problems exist in order to optimally apply resonance ionization spectroscopy (RIS) to the detection of sputtered neutral atoms, however. Several of these problems and their solutions are examined in this paper. First, the possible useful yields obtainable and the dependence of useful yield on various laser parameters for this type of sputtered neutral mass spectrometer (SNMS) are considered. Second, the choice of a mass spectrometer and its effect on the instrumental useful yield is explored in light of the unique ionization region for laser based SNMS. Finally a brief description of noise sources and their effect on the instrumental sensitivity is discussed. 33 refs., 12 figs

  14. Persistent challenges and frontiers in laser-based chemical analysis - signed, sealed, and delivered?

    International Nuclear Information System (INIS)

    Latkoczy, C.; Guenther, D.; Kaegi, R.

    2009-01-01

    Full text: The last years have been dedicated to push the spatial resolution capabilities of laser - based analytical methods towards the nanometer range. Progress, not just in the detection part using enhanced spectrometers but also in the laser sampling process itself using lasers with shorter pulse durations, paved the way to reach such limits. Nevertheless, the understanding of fundamental processes at such dimensions has gained more importance in order to explain and to control the various phenomena involved in the ablation and excitation processes. We will talk about current expectations, challenges and limitations, and present selected instrumental approaches to e.g. determine nanometer-sized colloid particles in aqueous systems. (author)

  15. Indirect Self-Destructiveness and Emotional Intelligence.

    Science.gov (United States)

    Tsirigotis, Konstantinos

    2016-06-01

    While emotional intelligence may have a favourable influence on the life and psychological and social functioning of the individual, indirect self-destructiveness exerts a rather negative influence. The aim of this study has been to explore possible relations between indirect self-destructiveness and emotional intelligence. A population of 260 individuals (130 females and 130 males) aged 20-30 (mean age of 24.5) was studied by using the Polish version of the chronic self-destructiveness scale and INTE, i.e., the Polish version of the assessing emotions scale. Indirect self-destructiveness has significant correlations with all variables of INTE (overall score, factor I, factor II), and these correlations are negative. The intensity of indirect self-destructiveness differentiates significantly the height of the emotional intelligence and vice versa: the height of the emotional intelligence differentiates significantly the intensity of indirect self-destructiveness. Indirect self-destructiveness has negative correlations with emotional intelligence as well as its components: the ability to recognize emotions and the ability to utilize emotions. The height of emotional intelligence differentiates the intensity of indirect self-destructiveness, and vice versa: the intensity of indirect self-destructiveness differentiates the height of emotional intelligence. It seems advisable to use emotional intelligence in the prophylactic and therapeutic work with persons with various types of disorders, especially with the syndrome of indirect self-destructiveness.

  16. Velocimetry using scintillation of a laser beam for a laser-based gas-flux monitor

    Science.gov (United States)

    Kagawa, Naoki; Wada, Osami; Koga, Ryuji

    1999-05-01

    This paper describes a velocimetry system using scintillation of a laser-beam with spatial filters based on sensor arrays for a laser- based gas flux monitor. In the eddy correlation method, gas flux is obtained by mutual relation between the gas density and the flow velocity. The velocimetry system is developed to support the flow velocity monitor portion of the laser-based gas flux monitor with a long span for measurement. In order to sense not only the flow velocity but also the flow direction, two photo diode arrays are arranged with difference of a quarter period of the weighting function between them; the two output signals from the sensor arrays have phase difference of either (pi) /2 or -(pi) /2 depending on the sense of flow direction. In order to obtain the flow velocity and the flow direction instantly, an electronic apparatus built by the authors extracts frequency and phase from crude outputs of the pair of sensors. A feasibility of the velocimetry was confirmed indoors by measurement of the flow- velocity vector of the convection. Measured flow-velocity vector of the upward flow agreed comparatively with results of an ultrasonic anemometer.

  17. In situ TEM Raman spectroscopy and laser-based materials modification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, F.I., E-mail: fiallen@lbl.gov [Department of Materials Science and Engineering, University of California, Berkeley, CA 94720 (United States); National Center for Electron Microscopy, Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Kim, E. [Department of Mechanical Engineering, University of California, Berkeley, CA 94720 (United States); Andresen, N.C. [Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Grigoropoulos, C.P. [Department of Mechanical Engineering, University of California, Berkeley, CA 94720 (United States); Minor, A.M., E-mail: aminor@lbl.gov [Department of Materials Science and Engineering, University of California, Berkeley, CA 94720 (United States); National Center for Electron Microscopy, Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2017-07-15

    We present a modular assembly that enables both in situ Raman spectroscopy and laser-based materials processing to be performed in a transmission electron microscope. The system comprises a lensed Raman probe mounted inside the microscope column in the specimen plane and a custom specimen holder with a vacuum feedthrough for a tapered optical fiber. The Raman probe incorporates both excitation and collection optics, and localized laser processing is performed using pulsed laser light delivered to the specimen via the tapered optical fiber. Precise positioning of the fiber is achieved using a nanomanipulation stage in combination with simultaneous electron-beam imaging of the tip-to-sample distance. Materials modification is monitored in real time by transmission electron microscopy. First results obtained using the assembly are presented for in situ pulsed laser ablation of MoS{sub 2} combined with Raman spectroscopy, complimented by electron-beam diffraction and electron energy-loss spectroscopy. - Highlights: • Raman spectroscopy and laser-based materials processing in a TEM are demonstrated. • A lensed Raman probe is mounted in the sample chamber for close approach. • Localized laser processing is achieved using a tapered optical fiber. • Raman spectroscopy and pulsed laser ablation of MoS{sub 2} are performed in situ.

  18. High-spatial-resolution sub-surface imaging using a laser-based acoustic microscopy technique.

    Science.gov (United States)

    Balogun, Oluwaseyi; Cole, Garrett D; Huber, Robert; Chinn, Diane; Murray, Todd W; Spicer, James B

    2011-01-01

    Scanning acoustic microscopy techniques operating at frequencies in the gigahertz range are suitable for the elastic characterization and interior imaging of solid media with micrometer-scale spatial resolution. Acoustic wave propagation at these frequencies is strongly limited by energy losses, particularly from attenuation in the coupling media used to transmit ultrasound to a specimen, leading to a decrease in the depth in a specimen that can be interrogated. In this work, a laser-based acoustic microscopy technique is presented that uses a pulsed laser source for the generation of broadband acoustic waves and an optical interferometer for detection. The use of a 900-ps microchip pulsed laser facilitates the generation of acoustic waves with frequencies extending up to 1 GHz which allows for the resolution of micrometer-scale features in a specimen. Furthermore, the combination of optical generation and detection approaches eliminates the use of an ultrasonic coupling medium, and allows for elastic characterization and interior imaging at penetration depths on the order of several hundred micrometers. Experimental results illustrating the use of the laser-based acoustic microscopy technique for imaging micrometer-scale subsurface geometrical features in a 70-μm-thick single-crystal silicon wafer with a (100) orientation are presented.

  19. In situ TEM Raman spectroscopy and laser-based materials modification

    International Nuclear Information System (INIS)

    Allen, F.I.; Kim, E.; Andresen, N.C.; Grigoropoulos, C.P.; Minor, A.M.

    2017-01-01

    We present a modular assembly that enables both in situ Raman spectroscopy and laser-based materials processing to be performed in a transmission electron microscope. The system comprises a lensed Raman probe mounted inside the microscope column in the specimen plane and a custom specimen holder with a vacuum feedthrough for a tapered optical fiber. The Raman probe incorporates both excitation and collection optics, and localized laser processing is performed using pulsed laser light delivered to the specimen via the tapered optical fiber. Precise positioning of the fiber is achieved using a nanomanipulation stage in combination with simultaneous electron-beam imaging of the tip-to-sample distance. Materials modification is monitored in real time by transmission electron microscopy. First results obtained using the assembly are presented for in situ pulsed laser ablation of MoS_2 combined with Raman spectroscopy, complimented by electron-beam diffraction and electron energy-loss spectroscopy. - Highlights: • Raman spectroscopy and laser-based materials processing in a TEM are demonstrated. • A lensed Raman probe is mounted in the sample chamber for close approach. • Localized laser processing is achieved using a tapered optical fiber. • Raman spectroscopy and pulsed laser ablation of MoS_2 are performed in situ.

  20. Final Report: Laser-Based Optical Trap for Remote Sampling of Interplanetary and Atmospheric Particulate Matter

    Science.gov (United States)

    Stysley, Paul

    2016-01-01

    Applicability to Early Stage Innovation NIAC Cutting edge and innovative technologies are needed to achieve the demanding requirements for NASA origin missions that require sample collection as laid out in the NRC Decadal Survey. This proposal focused on fully understanding the state of remote laser optical trapping techniques for capturing particles and returning them to a target site. In future missions, a laser-based optical trapping system could be deployed on a lander that would then target particles in the lower atmosphere and deliver them to the main instrument for analysis, providing remote access to otherwise inaccessible samples. Alternatively, for a planetary mission the laser could combine ablation and trapping capabilities on targets typically too far away or too hard for traditional drilling sampling systems. For an interstellar mission, a remote laser system could gather particles continuously at a safe distance; this would avoid the necessity of having a spacecraft fly through a target cloud such as a comet tail. If properly designed and implemented, a laser-based optical trapping system could fundamentally change the way scientists designand implement NASA missions that require mass spectroscopy and particle collection.

  1. Synchronization of indirectly coupled Lorenz oscillators

    Indian Academy of Sciences (India)

    Synchronization of indirectly coupled Lorenz oscillators: An experimental study. Amit Sharma Manish Dev Shrimali. Synchronization, Coupled Systems and Networks Volume 77 Issue 5 November 2011 pp 881-889 ... The in-phase and anti-phase synchronization of indirectly coupled chaotic oscillators reported in Phys. Rev ...

  2. Indirect search for dark matter with AMS

    International Nuclear Information System (INIS)

    Goy, Corinne

    2006-01-01

    This document summarises the potential of AMS in the indirect search for Dark Matter. Observations and cosmology indicate that the Universe may include a large amount of Dark Matter of unknown nature. A good candidate is the Ligthest Supersymmetric Particle in R-Parity conserving models. AMS offers a unique opportunity to study Dark Matter indirect signature in three spectra: gamma, antiprotons and positrons

  3. Indirectness in Discourse: Ethnicity as Conversational Style.

    Science.gov (United States)

    Tannen, Deborah

    1981-01-01

    Examines social differences in expectations of indirectness in conversations between married couples, both Greek and Greek-American. Concludes that Greeks are more likely to expect indirectness in the context presented and that Greek-Americans have retained the Greek communicative patterns. (FL)

  4. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    Directory of Open Access Journals (Sweden)

    Cătălina-Adriana Ivănuş

    2014-11-01

    Full Text Available The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  5. 77 FR 41899 - Indirect Food Additives: Polymers

    Science.gov (United States)

    2012-07-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 177 [Docket No. FDA-2012-F-0031] Indirect Food Additives: Polymers AGENCY: Food and Drug Administration, HHS. ACTION... CFR part 177 is amended as follows: PART 177--INDIRECT FOOD ADDITIVES: POLYMERS 0 1. The authority...

  6. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    OpenAIRE

    Cătălina-Adriana Ivănuş

    2014-01-01

    The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  7. Indirect techniques in nuclear astrophysics: a review.

    Science.gov (United States)

    Tribble, R E; Bertulani, C A; Cognata, M La; Mukhamedzhanov, A M; Spitaleri, C

    2014-10-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches.

  8. Indirect Calorimetry in Mechanically Ventilated Patients

    DEFF Research Database (Denmark)

    Allingstrup, Matilde Jo; Kondrup, Jens; Perner, Anders

    2017-01-01

    Background and Aims: The 2 currently available indirect calorimeters, CCM Express Indirect Calorimeter (MedGraphics, St Paul, MN) and Quark RMR ICU Indirect Calorimeter (COSMED, Rome, Italy), have not been validated against a gold standard in mechanically ventilated patients. Our aim was to do so...... using a gold-standard, modified Tissot bell-spirometer method in mechanically ventilated patients who were hemodynamically, respiratory, and metabolically stable. Methods: We studied 30 patients undergoing general anesthesia and major gynecological surgery. We measured oxygen consumption ((Formula...... of 77 (167) with limits of agreement −249 to 404 kcal/d. Conclusions: The QUARK RMR ICU Indirect Calorimeter compared better with the gold standard for values of (Formula presented.) O2 and REE than did the CCM Express Indirect Calorimeter in mechanically ventilated patients who were circulatory...

  9. Recent advances in ultrafast-laser-based spectroscopy and imaging for reacting plasmas and flames

    Science.gov (United States)

    Patnaik, Anil K.; Adamovich, Igor; Gord, James R.; Roy, Sukesh

    2017-10-01

    Reacting flows and plasmas are prevalent in a wide array of systems involving defense, commercial, space, energy, medical, and consumer products. Understanding the complex physical and chemical processes involving reacting flows and plasmas requires measurements of key parameters, such as temperature, pressure, electric field, velocity, and number densities of chemical species. Time-resolved measurements of key chemical species and temperature are required to determine kinetics related to the chemical reactions and transient phenomena. Laser-based, noninvasive linear and nonlinear spectroscopic approaches have proved to be very valuable in providing key insights into the physico-chemical processes governing reacting flows and plasmas as well as validating numerical models. The advent of kilohertz rate amplified femtosecond lasers has expanded the multidimensional imaging of key atomic species such as H, O, and N in a significant way, providing unprecedented insight into preferential diffusion and production of these species under chemical reactions or electric-field driven processes. These lasers not only provide 2D imaging of chemical species but have the ability to perform measurements free of various interferences. Moreover, these lasers allow 1D and 2D temperature-field measurements, which were quite unimaginable only a few years ago. The rapid growth of the ultrafast-laser-based spectroscopic measurements has been fueled by the need to achieve the following when measurements are performed in reacting flows and plasmas. They are: (1) interference-free measurements (collision broadening, photolytic dissociation, Stark broadening, etc), (2) time-resolved single-shot measurements at a rate of 1-10 kHz, (3) spatially-resolved measurements, (4) higher dimensionality (line, planar, or volumetric), and (5) simultaneous detection of multiple species. The overarching goal of this article is to review the current state-of-the-art ultrafast-laser-based spectroscopic

  10. Expression of future prospective in indirect speech

    Directory of Open Access Journals (Sweden)

    Bodnaruk Elena Vladimirovna

    2015-03-01

    Full Text Available The article analyzes the characteristics and use of grammatical semantics and lexical and grammatical means used to create future prospects in double indirect discourse. The material for the study were epic works by contemporary German writers. In the analysis of the empirical material it has been pointed out that indirect discourse has preterial basis and is the kind of most frequent inner speech of characters. The most widely used form with future semantics in preterial indirect speech is conditional I, formally having a conjunctive basis, but is mostly used with the indicative semantics. Competitive to conditional I in indirect speech is preterial indicative. A characteristic feature of the indirect speech is the use of modal verbs, which, thanks to its semantics is usually referred as an action at a later term, creating the prospect of future statements. The most frequent were modal verbs wollen and sollen in the form of the preterite, more rare verbs were m ssen and k nnen. German indirect speech distinguishes the ability to use forms on the basis of conjunctive: preterite and plusquamperfect of conjunctive. Both forms express values similar to those of the indicative. However, conjunctive forms the basis of the data shown in a slightly more pronounced seme of uncertainty that accompanies future uses of these forms in indirect speech. In addition, plusquamperfect conjunctive differs from others by the presence of the seme of completeness.

  11. Gel dosimetry - a laser based 3D scanner for gel samples - research in India

    Energy Technology Data Exchange (ETDEWEB)

    Widmer, Johannes [Institut fuer Angewandte Photophysik, TU Dresden (Germany); Photonics Division, VIT University, Vellore, Tamil Nadu (India); Dhiviyaraj Kalaiselven, Senthil Kumar [Photonics Division, VIT University, Vellore, Tamil Nadu (India); Department of Therapeutic Radiology, University of Minnesota, Minneapolis (United States); James, Jebaseelan Samuel [Photonics Division, VIT University, Vellore, Tamil Nadu (India)

    2013-07-01

    A laser based 3D scanner is developed to take tomography images of partly transparent samples. The scanner is optimized to characterize gel samples from spatially resolved dosimetry measurements. The resulting device should be suitably designed to be constructed in India. This gave me valuable insight into the scientific and technological environment of the country and made me find my way through a quite different culture of research and commerce, within and beyond the scientific context of the university. The project was implemented during a nine months stay at the Vellore Institute of Technology University in Vellore, Tamil Nadu, India, in co-operation with the Christian Medical College, Vellore, in 2006/07. It was conducted within the framework of existing research activities of the host university.

  12. Development of Laser Based Remote Sensing System for Inner-Concrete Defects

    Science.gov (United States)

    Shimada, Yoshinori; Kotyaev, Oleg

    Laser-based remote sensing using a vibration detection system has been developed using a photorefractive crystal to reduce the effect of concrete surface-roughness. An electric field was applied to the crystal and the reference beam was phase shifted to increase the detection efficiency (DE). The DE increased by factor of 8.5 times compared to that when no voltage and no phase shifting were applied. Vibration from concrete defects can be detected at a distance of 5 m from the system. A vibration-canceling system has also developed that appears to be promising for canceling vibrations between the laser system and the concrete. Finally, we have constructed a prototype system that can be transported in a small truck.

  13. Enhancing Surface Finish of Additively Manufactured Titanium and Cobalt Chrome Elements Using Laser Based Finishing

    Science.gov (United States)

    Gora, Wojciech S.; Tian, Yingtao; Cabo, Aldara Pan; Ardron, Marcus; Maier, Robert R. J.; Prangnell, Philip; Weston, Nicholas J.; Hand, Duncan P.

    Additive manufacturing (AM) offers the possibility of creating a complex free form object as a single element, which is not possible using traditional mechanical machining. Unfortunately the typically rough surface finish of additively manufactured parts is unsuitable for many applications. As a result AM parts must be post-processed; typically mechanically machined and/or and polished using either chemical or mechanical techniques (both of which have their limitations). Laser based polishing is based on remelting of a very thin surface layer and it offers potential as a highly repeatable, higher speed process capable of selective area polishing, and without any waste problems (no abrasives or liquids). In this paper an in-depth investigation of CW laser polishing of titanium and cobalt chrome AM elements is presented. The impact of different scanning strategies, laser parameters and initial surface condition on the achieved surface finish is evaluated.

  14. Ultrafast Laser-Based Spectroscopy and Sensing: Applications in LIBS, CARS, and THz Spectroscopy

    Science.gov (United States)

    Leahy-Hoppa, Megan R.; Miragliotta, Joseph; Osiander, Robert; Burnett, Jennifer; Dikmelik, Yamac; McEnnis, Caroline; Spicer, James B.

    2010-01-01

    Ultrafast pulsed lasers find application in a range of spectroscopy and sensing techniques including laser induced breakdown spectroscopy (LIBS), coherent Raman spectroscopy, and terahertz (THz) spectroscopy. Whether based on absorption or emission processes, the characteristics of these techniques are heavily influenced by the use of ultrafast pulses in the signal generation process. Depending on the energy of the pulses used, the essential laser interaction process can primarily involve lattice vibrations, molecular rotations, or a combination of excited states produced by laser heating. While some of these techniques are currently confined to sensing at close ranges, others can be implemented for remote spectroscopic sensing owing principally to the laser pulse duration. We present a review of ultrafast laser-based spectroscopy techniques and discuss the use of these techniques to current and potential chemical and environmental sensing applications. PMID:22399883

  15. Laser Based In Situ Techniques: Novel Methods for Generating Extreme Conditions in TEM Samples

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, M; Lagrange, T; Reed, B; Armstrong, M; Campbell, G; DeHope, W; Kim, J; King, W; Masiel, D; Browning, N

    2008-02-25

    The Dynamic Transmission Electron Microscope (DTEM) is introduced as a novel tool for in situ processing of materials. Examples of various types of dynamic studies outline the advantages and differences of laser-based heating in the DTEM in comparison to conventional (resistive) heating in situ TEM methods. We demonstrate various unique capabilities of the drive laser, namely, in situ processing of nanoscale materials, rapid and high temperature phase transformations, and controlled thermal activation of materials. These experiments would otherwise be impossible without the use of the DTEM drive laser. Thus, the potential of the DTEM to as a new technique to process and characterize the growth of a myriad of micro and nanostructures is demonstrated.

  16. L-band passively harmonic mode-locked fiber laser based on a graphene saturable absorber

    International Nuclear Information System (INIS)

    Du, J; Zhang, S M; Li, H F; Meng, Y C; Li, X L; Hao, Y P

    2012-01-01

    We have proposed and demonstrated an L-band passively harmonic mode-locked fiber laser based on a graphene saturable absorber (SA). By adjusting the pump power and the polarization controller, we have experimentally observed L-band fundamental and harmonic mode-locked optical pulses. The fundamental optical pulse has the duration of 1.3 ps, and the maximum average output power of 13.16 mW at the incident pump power of 98.8 mW. The order of the harmonic mode-locked optical pulses can be changed over the range from the second to the fourth. From the experimental results, we deduced that the likely origin of the harmonic mode-locked self-stabilization was the result of global and local soliton interactions induced by the unstability continuous wave (CW) components

  17. Calibration-free absolute frequency response measurement of directly modulated lasers based on additional modulation.

    Science.gov (United States)

    Zhang, Shangjian; Zou, Xinhai; Wang, Heng; Zhang, Yali; Lu, Rongguo; Liu, Yong

    2015-10-15

    A calibration-free electrical method is proposed for measuring the absolute frequency response of directly modulated semiconductor lasers based on additional modulation. The method achieves the electrical domain measurement of the modulation index of directly modulated lasers without the need for correcting the responsivity fluctuation in the photodetection. Moreover, it doubles measuring frequency range by setting a specific frequency relationship between the direct and additional modulation. Both the absolute and relative frequency response of semiconductor lasers are experimentally measured from the electrical spectrum of the twice-modulated optical signal, and the measured results are compared to those obtained with conventional methods to check the consistency. The proposed method provides calibration-free and accurate measurement for high-speed semiconductor lasers with high-resolution electrical spectrum analysis.

  18. Laser-Based Spatio-Temporal Characterisation of Port Fuel Injection (PFI Sprays

    Directory of Open Access Journals (Sweden)

    C. T. N. Anand

    2010-06-01

    Full Text Available In the present work, detailed laser-based diagnostic experiments were conducted to characterise the spray from low pressure 2-hole and 4-hole Port Fuel Injection (PFI injectors. The main objective of the work included obtaining quantitative information of the spatio-temporal spray structure of such low-pressure gasoline sprays. A novel approach involving a combination of techniques such as Mie scattering, Granulometry, and Laser Sheet Dropsizing (LSD was used to study the spray structure. The droplet sizes, distributions with time, Sauter Mean Diameters (SMD, droplet velocities, cone angles and spray tip penetrations of the sprays from the injectors were determined. The spray from these injectors is found to be ‘pencil like’ and not dispersed as in high pressure sprays. The application of the above mentioned techniques provides two-dimensional SMD contours of the entire spray at different instants of time, with reasonable accuracy.

  19. Ultrafast Laser-Based Spectroscopy and Sensing: Applications in LIBS, CARS, and THz Spectroscopy

    Directory of Open Access Journals (Sweden)

    Megan R. Leahy-Hoppa

    2010-04-01

    Full Text Available Ultrafast pulsed lasers find application in a range of spectroscopy and sensing techniques including laser induced breakdown spectroscopy (LIBS, coherent Raman spectroscopy, and terahertz (THz spectroscopy. Whether based on absorption or emission processes, the characteristics of these techniques are heavily influenced by the use of ultrafast pulses in the signal generation process. Depending on the energy of the pulses used, the essential laser interaction process can primarily involve lattice vibrations, molecular rotations, or a combination of excited states produced by laser heating. While some of these techniques are currently confined to sensing at close ranges, others can be implemented for remote spectroscopic sensing owing principally to the laser pulse duration. We present a review of ultrafast laser-based spectroscopy techniques and discuss the use of these techniques to current and potential chemical and environmental sensing applications.

  20. Development of a Laser-based Emittance Monitor for Negative Hydrogen Beams

    CERN Document Server

    AUTHOR|(CDS)2078368; Schmauss, Bernhard; Gibson, Stephen; Boorman, Gary; Bosco, Alessio

    High energy particle accelerators are designed to collide charged particle beams and thus study the collision products. Maximising the collision rate, to generate sufficient statistics for precise measurements of rare processes, is one of the key parameters for optimising the overall collider performance. The CERN Large Hadron Collider (LHC) Injectors Upgrade (LIU) includes the construction of LINAC4, a completely new machine working as a first linear acceleration stage for the LHC beam. By accelerating a negative hydrogen beam (H-) instead of protons, it aims to double the beam brightness via a more efficient transfer to the first circular accelerator and subsequently boost the LHC collision rate. To achieve this, a precise knowledge of the transverse beam characteristics in terms of beam emittance is essential. This thesis work covers the development of a laser-based monitor meant to measure non-destructively the LINAC4 beam transverse profile and emittance. This included the implementation of dif...

  1. Diode-pumped two-frequency lasers based on c-cut vanadate crystals

    International Nuclear Information System (INIS)

    Sirotkin, A A; Garnov, Sergei V; Zagumennyi, A I; Zavartsev, Yu D; Kutovoi, S A; Vlasov, V I; Shcherbakov, Ivan A

    2009-01-01

    The luminescent and lasing properties of the neo-dymium ion at the 4 F 3/2 - 4 I 11/2 transition in c-cut vanadate crystals (Nd:YVO 4 , Nd:GdVO 4 , and Nd:Gd 1-x Y x VO 4 ) are studied. Tuning of the laser radiation wavelength (Δλ = 5.4 nm) is demonstrated. Two-frequency laser schemes with the use of a Lyot filter, a Fabry-Perot etalon, and a Brewster prism as spectral selection elements are proposed and experimentally realised. Stable two-frequency lasing of a laser based on the c-cut Nd:GdVO 4 crystal was obtained in the cw, Q-switched (nanosecond pulses), and active acousto-optic mode-locked (picosecond pulses) regimes. (lasers)

  2. Retrieval Algorithms for Road Surface Modelling Using Laser-Based Mobile Mapping

    Directory of Open Access Journals (Sweden)

    Antero Kukko

    2008-09-01

    Full Text Available Automated processing of the data provided by a laser-based mobile mapping system will be a necessity due to the huge amount of data produced. In the future, vehiclebased laser scanning, here called mobile mapping, should see considerable use for road environment modelling. Since the geometry of the scanning and point density is different from airborne laser scanning, new algorithms are needed for information extraction. In this paper, we propose automatic methods for classifying the road marking and kerbstone points and modelling the road surface as a triangulated irregular network. On the basis of experimental tests, the mean classification accuracies obtained using automatic method for lines, zebra crossings and kerbstones were 80.6%, 92.3% and 79.7%, respectively.

  3. A laser-based beam profile monitor for the SLC/SLD interaction region

    International Nuclear Information System (INIS)

    Alley, R.; Arnett, D.; Bong, E.; Colocho, W.; Frisch, J.; Horton-Smith, S.; Inman, W.; Jobe, K.; Kotseroglou, T.; McCormick, D.; Nelson, J.; Scheeff, M.; Wagner, S.; Ross, M.C.

    1996-01-01

    Beam size estimates made using beam-beam deflections are used for optimization of the Stanford linear collider (SLC) electron-positron beam sizes. Typical beam sizes and intensities expected for 1996 operations are 2.1 x 0.6 μm (x, y) at 4.0.10 10 particles per pulse. Conventional profile monitors, such as scanning wires, fail at charge densities well below this. The laser-based profile monitor uses a finely-focused 350-nm wavelength tripled YLF laser pulse that traverses the particle beam path about 29 cm away from the e + /e - IP. Compton scattered photons and degraded e + /e - are detected as the beam is steered across the laser pulse. The laser pulse has a transverse size of 380 nm and a Rayleigh range of about 5 μm. (orig.)

  4. Laser-based terahertz-field-driven streak camera for the temporal characterization of ultrashort processes

    International Nuclear Information System (INIS)

    Schuette, Bernd

    2011-09-01

    In this work, a novel laser-based terahertz-field-driven streak camera is presented. It allows for a pulse length characterization of femtosecond (fs) extreme ultraviolet (XUV) pulses by a cross-correlation with terahertz (THz) pulses generated with a Ti:sapphire laser. The XUV pulses are emitted by a source of high-order harmonic generation (HHG) in which an intense near-infrared (NIR) fs laser pulse is focused into a gaseous medium. The design and characterization of a high-intensity THz source needed for the streak camera is also part of this thesis. The source is based on optical rectification of the same NIR laser pulse in a lithium niobate crystal. For this purpose, the pulse front of the NIR beam is tilted via a diffraction grating to achieve velocity matching between NIR and THz beams within the crystal. For the temporal characterization of the XUV pulses, both HHG and THz beams are focused onto a gas target. The harmonic radiation creates photoelectron wavepackets which are then accelerated by the THz field depending on its phase at the time of ionization. This principle adopted from a conventional streak camera and now widely used in attosecond metrology. The streak camera presented here is an advancement of a terahertz-field-driven streak camera implemented at the Free Electron Laser in Hamburg (FLASH). The advantages of the laser-based streak camera lie in its compactness, cost efficiency and accessibility, while providing the same good quality of measurements as obtained at FLASH. In addition, its flexibility allows for a systematic investigation of streaked Auger spectra which is presented in this thesis. With its fs time resolution, the terahertz-field-driven streak camera thereby bridges the gap between attosecond and conventional cameras. (orig.)

  5. Laser-based terahertz-field-driven streak camera for the temporal characterization of ultrashort processes

    Energy Technology Data Exchange (ETDEWEB)

    Schuette, Bernd

    2011-09-15

    In this work, a novel laser-based terahertz-field-driven streak camera is presented. It allows for a pulse length characterization of femtosecond (fs) extreme ultraviolet (XUV) pulses by a cross-correlation with terahertz (THz) pulses generated with a Ti:sapphire laser. The XUV pulses are emitted by a source of high-order harmonic generation (HHG) in which an intense near-infrared (NIR) fs laser pulse is focused into a gaseous medium. The design and characterization of a high-intensity THz source needed for the streak camera is also part of this thesis. The source is based on optical rectification of the same NIR laser pulse in a lithium niobate crystal. For this purpose, the pulse front of the NIR beam is tilted via a diffraction grating to achieve velocity matching between NIR and THz beams within the crystal. For the temporal characterization of the XUV pulses, both HHG and THz beams are focused onto a gas target. The harmonic radiation creates photoelectron wavepackets which are then accelerated by the THz field depending on its phase at the time of ionization. This principle adopted from a conventional streak camera and now widely used in attosecond metrology. The streak camera presented here is an advancement of a terahertz-field-driven streak camera implemented at the Free Electron Laser in Hamburg (FLASH). The advantages of the laser-based streak camera lie in its compactness, cost efficiency and accessibility, while providing the same good quality of measurements as obtained at FLASH. In addition, its flexibility allows for a systematic investigation of streaked Auger spectra which is presented in this thesis. With its fs time resolution, the terahertz-field-driven streak camera thereby bridges the gap between attosecond and conventional cameras. (orig.)

  6. Indirect estimators in US federal programs

    CERN Document Server

    1996-01-01

    In 1991, a subcommittee of the Federal Committee on Statistical Methodology met to document the use of indirect estimators - that is, estimators which use data drawn from a domain or time different from the domain or time for which an estimate is required. This volume comprises the eight reports which describe the use of indirect estimators and they are based on case studies from a variety of federal programs. As a result, many researchers will find this book provides a valuable survey of how indirect estimators are used in practice and which addresses some of the pitfalls of these methods.

  7. Detection of tumor-specific cytotoxic drug activity in vitro using the fluorometric microculture cytotoxicity assay and primary cultures of tumor cells from patients.

    Science.gov (United States)

    Nygren, P; Fridborg, H; Csoka, K; Sundström, C; de la Torre, M; Kristensen, J; Bergh, J; Hagberg, H; Glimelius, B; Rastad, J

    1994-03-01

    The semi-automated fluorometric microculture cytotoxicity assay (FMCA), based on the measurement of fluorescence generated from cellular hydrolysis of fluorescein diacetate (FDA) by viable cells, was employed for cytotoxic drug sensitivity testing of tumor cells from patients with hematological or solid tumors. In total, 390 samples from 20 diagnoses were tested with up to 12 standard cytotoxic drugs. The technical success rate for different tumor types ranged from 67 to 95%. Fluorescence was linearly related to cell number but variably steep depending on tumor type. Samples from most solid tumors thus showed higher signal-to-noise ratios than hematological samples. A wide spectrum of in vitro drug activity was obtained, with acute leukemias and non-Hodgkin's lymphomas being sensitive to almost all tested drugs, whereas renal and adrenocortical carcinomas were essentially totally resistant. Between these extremes were samples of breast and ovarian carcinomas and sarcomas. When in vitro response was compared with known clinical response patterns, a good correspondence was observed. The results indicate that the FMCA is a rapid and efficient method for in vitro measurement of tumor-specific drug activity both in hematological and in solid tumors. The assay may be suitable for new drug development and direction of phase-2 trials to suitable patients.

  8. Prediction of individual patient response to chemotherapy by the fluorometric microculture cytotoxicity assay (FMCA) using drug specific cut-off limits and a Bayesian model.

    Science.gov (United States)

    Larsson, R; Nygren, P

    1993-01-01

    The semiautomated fluorometric microculture cytotoxicity assay (FMCA) based on the measurement of fluorescence generated from cellular hydrolysis of fluorescein diacetate (FDA) to fluorescein in microtiter plates, has been used for determination of cytotoxic drug resistance of tumor cells from patients with hematological and solid tumors. In the present study we describe a calibration procedure based on statistically derived cut-off limits and assay-predicted response probabilities using Bayes' theorem. Test results at a specified drug concentration were divided into three categories: low, intermediate or extreme drug resistance (LDR, IDR and EDR, respectively) using the median and median +1 standard deviation as the cut-off limits. When correlated with clinical outcome, LDR samples showed a higher response rate than expected, IDR a lower and EDR samples no response at all. The sensitivity and specificity of the test, using the median as cut-off limit, were 0.92 and 0.69 respectively. By fitting these test characteristics to a statistical model based on Bayes' theorem it is possible to calculate response probabilities for each individual patient taking into consideration not only the test characteristics and the particular assay result, but also the clinical and patient specific characteristics influencing the pre-test probability of response. EDR predicts clinical drug resistance with high specificity and is also observed in tumor types with high response rate.

  9. Feasibility of the fluorometric microculture cytotoxicity assay (FMCA) for cytotoxic drug sensitivity testing of tumor cells from patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Nygren, P; Kristensen, J; Jonsson, B; Sundström, C; Lönnerholm, G; Kreuger, A; Larsson, R

    1992-11-01

    The automated fluorometric microculture cytotoxicity assay (FMCA) was used for chemotherapeutic drug sensitivity testing of fresh and cryopreserved tumor cells from patients with acute lymphoblastic leukemia (ALL) at diagnosis and relapse. The technique success rate was 87% for fresh and 81% for cryopreserved samples. Up to 16 different cytotoxic drugs were routinely tested, but neither asparaginase nor methotrexate produced dose-response related cell kill. FMCA data showed good correlation to the well established Disc assay and the drug sensitivity reported by the FMCA was in good agreement with known clinical activity. Samples from children and initial ALL tended to be more drug sensitive than those from adults and ALL at relapse, respectively. For 36 samples clinical outcome was correlated to the quartile position in comparison to all other samples for the most in vitro active drug actually given to the patient. For patients with samples in the first, second, third, and fourth quartiles, the probabilities of complete remission were 89, 57, 38, and 0%, respectively. Using the median value as cut-off line, the sensitivity and specificity of the assay were 87 and 62%, respectively. It is concluded that the FMCA with a minimum of effort and with high success rate report clinically relevant drug sensitivity profiles for ALL.

  10. In vitro drug sensitivity testing of tumor cells from patients with non-Hodgkin's lymphoma using the fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Nygren, P; Hagberg, H; Glimelius, B; Sundström, C; Kristensen, J; Christiansen, I; Larsson, R

    1994-01-01

    Tumor cell drug sensitivity is an important determinant of chemotherapy response. Its measurement in vitro would aid in therapy individualization and new drug development. The fluorometric microculture cytotoxicity assay (FMCA), based on production by viable cells of fluorescent fluorescein after 3 days of culture, was used for cytotoxic drug sensitivity testing of 73 samples of tumor cells from patients with non-Hodgkin's lymphoma (NHL). The technical success rate was 92%, and FMCA data showed good correlation to the Disc assay. NHL samples were considerably more drug sensitive than were samples from in vivo resistant tumors. There was no obvious difference in drug sensitivity for high- vs. low-grade or untreated vs. previously treated low-grade NHL. For 26 patients, clinical outcome was correlated to in vitro response giving a sensitivity and specificity of 93 and 48%, respectively. Cross-resistance between standard drugs was frequent in vitro. Resistance modulators potentiated the effect of vincristine and doxorubicin in 10-29% of the samples, most frequently from previously treated patients. The FMCA seems to report clinically relevant drug sensitivity data for NHL, and thus it could serve as a tool for optimization of chemotherapy in the future.

  11. New colorimetric and fluorometric sensing strategy based on the anisotropic growth of histidine-mediated synthesis of gold nanoclusters for iodide-specific detection.

    Science.gov (United States)

    Wang, Yifeng; Zhu, Haiyan; Yang, Xiaoming; Dou, Yao; Liu, Zhongde

    2013-04-07

    Iodide, as a biologically important anion, it remains a worthwhile yet challenging undertaking to find a sensitive and specific approach to provide a technically simple iodide detection. In this article, it was found that no other ions than iodide-induced anisotropic growth of gold nanocrystals (AuNCs) originated from a small molecule, histidine-mediated synthesis of AuNCs, were observed. Simultaneously, it is accompanied by the fluorescence quenching of AuNCs and the naked-eye visible color change. Therefore, a new colorimetric and fluorometric sensing strategy was developed for the iodide-specific detection. Compared with currently reported methods, the present one displays the advantages of the visual detection and simplicity. The quenched fluorescence and enhanced surface plasmon resonance absorbance were found to be proportional to the iodide concentration over the range of 0.8-60 and 1.2-50 μM with a detection limit (3σ) of 118 nM and 215 nM, respectively.

  12. The effect of glucose stimulation on 45calcium uptake of rat pancreatic islets and their total calcium content as measured by a fluorometric micro-method

    International Nuclear Information System (INIS)

    Wolters, G.H.J.; Wiegman, J.B.; Konijnendijk, W.

    1982-01-01

    Glucose-stimulated 45 calcium uptake and total calcium content of rat pancreatic islets has been studied, using a new fluorometric micro-method to estimate total calcium. Extracellular calcium was separated from incubated tissue by a rapid micro-filtration procedure. Islets incubated up to 60 min with calcium chloride 2.5 mmol/l and glucose 2.5 mmol/l maintained the same calcium content (670 +- 7.5 pmol/μg DNA). When the glucose concentration was raised to 15 mmol/l no change in the total calcium content could be detected. On incubation with glucose 2.5 mmol/l in the absence of calcium, the calcium content decreased to 488 +- 27 pmol/μg DNA. On incubation with 45 calcium chloride 2.5 mmol/l for 5 or 30 min at 2.5 mmol/l glucose, islets exchanged 21 +- 2 and 28 +- 1% of their total calcium content and, at 15 mmol/l glucose, 30 +- 3 and 45 +- 2%, respectively. Thus, islet calcium has a high turn-over rate. Glucose stimulation results in an increase of the calcium uptake without enhancing the total calcium content and hence must increase the calcium-exchangeable pool. (orig.)

  13. Demonstration of tyrosinase in the vitiligo skin of human beings by a sensitive fluorometric method as well as by 14C(U)-L-tyrosine incorporation into melanin

    International Nuclear Information System (INIS)

    Husain, I.; Vijayan, E.; Ramaiah, A.; Pasricha, J.S.; Madan, N.C.

    1982-01-01

    Tyrosinase activity (Monophenol, dihydroxyphenylalanine: oxygen oxidoreductase EC 1.14.18.1) in vitiligo and normal epidermal homogenates of skin from human beings was measured by estimating beta 3,4-dihydroxyphenylalanine (dopa) by a highly sensitive fluorometric method described in this paper. The tyrosine activity in the vitiligo skin was about 4 to 37% of corresponding normal skin. The activity of tyrosinase in normal human skin from different individuals and from different regions of the body was in the range of 4 to 140 picomoles of beta 3,4-dihydroxyphenylalanine formed per min/mg protein of epidermal homogenate. The enzyme from vitiligo and normal skin was severely inhibited by substance(s) of low molecular weight. The enzyme exhibits a lag of about 4 hr in the absence of added beta 3,4-dihydroxyphenylalanine and 1 hr in presence of 5 microM dopa. Tyrosinase from the normal and vitiligo skin was inhibited by excess concentration of tyrosine. The homogenates from vitiligo skin could synthesize melanin from C14(U)-L-Tyrosine. The rate of tyrosine incorporation into melanin by the epidermal homogenates is increased by 3,4-dihydroxyphenylalanine (dopa) disproportionate to its effect on tyrosinase activity. Based on the data presented in this paper it is concluded that melanocytes are present in the vitiligo skin. A tentative hypothesis is put forward to explain the lack of melanin synthesis by the vitiligo skin under in vivo conditions, although melanocytes are present

  14. Bioelectrochemical Systems for Indirect Biohydrogen Production

    KAUST Repository

    Regan, John M.; Yan, Hengjing

    2014-01-01

    by exoelectrogens at the anode. As an indirect approach to biohydrogen production, these systems are not subject to the hydrogen yield constraints of fermentative processes and have been proven to work with virtually any biodegradable organic substrate

  15. Indirect techniques in nuclear astrophysics: a review

    International Nuclear Information System (INIS)

    Tribble, R E; Mukhamedzhanov, A M; Bertulani, C A; Cognata, M La; Spitaleri, C

    2014-01-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches. (review article)

  16. An Indirect Route for Ethanol Production

    Energy Technology Data Exchange (ETDEWEB)

    Eggeman, T.; Verser, D.; Weber, E.

    2005-04-29

    The ZeaChem indirect method is a radically new approach to producing fuel ethanol from renewable resources. Sugar and syngas processing platforms are combined in a novel way that allows all fractions of biomass feedstocks (e.g. carbohydrates, lignins, etc.) to contribute their energy directly into the ethanol product via fermentation and hydrogen based chemical process technologies. The goals of this project were: (1) Collect engineering data necessary for scale-up of the indirect route for ethanol production, and (2) Produce process and economic models to guide the development effort. Both goals were successfully accomplished. The projected economics of the Base Case developed in this work are comparable to today's corn based ethanol technology. Sensitivity analysis shows that significant improvements in economics for the indirect route would result if a biomass feedstock rather that starch hydrolyzate were used as the carbohydrate source. The energy ratio, defined as the ratio of green energy produced divided by the amount of fossil energy consumed, is projected to be 3.11 to 12.32 for the indirect route depending upon the details of implementation. Conventional technology has an energy ratio of 1.34, thus the indirect route will have a significant environmental advantage over today's technology. Energy savings of 7.48 trillion Btu/yr will result when 100 MMgal/yr (neat) of ethanol capacity via the indirect route is placed on-line by the year 2010.

  17. Application of laser-based photoacoustic spectroscopy and colorimetry for quantification of anthocyanin in hard boiled candy

    NARCIS (Netherlands)

    Kovács, Mihály; Dóka, Ottó; Bicanic, Dane; Ajtony, Zsolt

    2017-01-01

    The analytical performance of the newly proposed laser-based photoacoustic spectroscopy (LPAS) and colorimetric method for quantification of anthocyanin (E163) in commercially available hard boiled candies are compared to that of the spectrophotometry (SP). Both LPAS and colorimetry are direct

  18. 77 FR 13367 - General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-06

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0157] General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment Facility, Wilmington, NC AGENCY: Nuclear Regulatory... Impact Statement (EIS) for the proposed General Electric- Hitachi Global Laser Enrichment, LLC (GLE...

  19. Laser-based sensors on UAVs for quantifying local emissions of greenhouse gases

    Science.gov (United States)

    Zondlo, Mark; Tao, Lei; O'Brien, Anthony; Ross, Kevin; Khan, Amir; Pan, Da; Golston, Levi; Sun, Kang; DiGangi, Josh

    2015-04-01

    Small unmanned aerial systems (UAS) provide an ideal platform to sample both locally near an emission source as well as within the atmospheric boundary layer. However, small UAS (those with wingspans or rotors on the order of a meter) place severe constraints on sensor size (~ liter volume), mass (~ kg), and power (10s W). Laser-based sensors employing absorption techniques are ideally suited for such platforms due to their high sensitivity, high selectivity, and compact footprint. We have developed and flown compact sensors for water vapor, carbon dioxide and methane using new advances in open-path, laser-based spectroscopy on a variety of platforms ranging from remote control helicopters to long-duration UAS. Open-path spectroscopy allows for high frequency sampling (10-25 Hz) while avoiding the size/mass/power of sample delays, inlet lines, and pumps. To address the challenges of in-flight stability in changing environmental conditions and any associated flight artifacts on the measurement itself (e.g. vibrations), we use an in-line reference cell at a reduced pressure (10 hPa) to account for systematic drift continuously while in flight. Wavelength modulation spectroscopy is used at different harmonics to isolate the narrow linewidth of the in-line reference signal from the ambient, pressure-broadened absorption lineshape of the trace gas of interest. As a result, a metric of in-flight performance is achieved in real-time on the same optical pathlength as the ambient signal. To demonstrate the great potential of laser-based sensors on UAS, we deployed a 1.65 micron-based methane sensor (4 kg, 50 W, 100 ppbv precision at 10 Hz) on a UT-Dallas remote control aircraft for two weeks around gas/oil extraction activities as part of the EDF Barnett Coordinated Campaign in October 2013. We conducted thirty-four flights around a compressor station to examine the spatial and temporal characteristics of its emissions. Leaks of methane were typically lofted to altitudes

  20. Design and Implementation of a Laser-Based Ammonia Breath Sensor for Medical Applications

    KAUST Repository

    Owen, Kyle

    2012-06-01

    Laser-based sensors can be used as non-invasive monitoring tools to measure parts per billion (ppb) levels of trace gases. Ammonia sensors are useful for applications in environmental pollutant monitoring, atmospheric and combustion kinetic studies, and medical diagnostics. This sensor was specifically designed to measure ammonia in exhaled breath to be used as a medical diagnostic and monitoring tool, however, it can also be extended for use in other applications. Although ammonia is a naturally occurring species in exhaled breath, abnormally elevated levels can be an indication of adverse medical conditions. Laser-based breath diagnostics have many benefits since they are cost effective, non-invasive, painless, real time monitors. They have the potential to improve the quality of medical care by replacing currently used blood tests and providing immediate feedback to physicians. This sensor utilizes a Quantum Cascade Laser and Wavelength Modulation Spectroscopy with second harmonic normalized by first harmonic detection in a 76 m multi-pass absorption cell to measure ppb levels of ammonia with improved sensitivity over previous sensors. Initial measurements to determine the ammonia absorption line parameters were performed using direct absorption spectroscopy. This is the first experimental study of the ammonia absorption line transitions near 1103.46 cm1 with absorption spectroscopy. The linestrengths were measured with uncertainties less than 10%. The collisional broadening coefficients for each of the ammonia lines with nitrogen, oxygen, water vapor, and carbon dioxide were also measured, many of which had uncertainties less than 5%. The sensor was characterized to show a detectability limit of 10 ppb with an uncertainty of less than 5% at typical breath ammonia levels. Initial breath test results showed that some of the patients with chronic kidney disease had elevated ammonia levels while others had ammonia levels in the same range as expected for healthy

  1. Analysis of indirect taxation in Ukraine

    Directory of Open Access Journals (Sweden)

    Khodyakova Olga V.

    2014-01-01

    Full Text Available The goal of the article is analysis of the structure and dynamics of indirect taxes for the previous five years and also the influence of indirect taxation upon formation of income of the State Budget of Ukraine. The article analyses the modern state of indirect taxation in Ukraine. Specific weight of the value added tax, excise tax and customs duty are considered in the structure of tax receipts of the consolidated budget of Ukraine as indirect taxes. The article shows that receipts of the State Budget of Ukraine are mostly provided by indirect taxes. The Ukrainian taxation system is mostly a factor of reduction of the level of economic growth and investment activity in the country and the existing system of administering is not completely capable of excluding the possibility of tax evasion. The prospect of further studies in this direction is improvement of organisation of tax control in Ukraine and differentiation of the value added tax rates depending on the level of consumption of goods and level of income of consumers.

  2. Laser-based microstructuring of materials surfaces using low-cost microlens arrays

    Science.gov (United States)

    Nieto, Daniel; Vara, G.; Diez, J. A.; O`Connor, Gerard M.; Arines, Justo; Gómez-Reino, C.; Flores-Arias, M.

    2012-03-01

    Since frictional interactions in microscopically small components are becoming increasingly important for the development of new products for all modern technology, we present a laser-based technique for micro-patterning surfaces of materials using low-cost microlens arrays. The microlens used were fabricated on soda-lime glass using a laser direct-write technique, followed by a thermal treatment into an oven. By combining laser direct-write and the thermal treatment it was possible to obtain high quality elements using a low cost infrared laser widely implemented in industry which makes this technique attractive in comparison with other more expensive methods. The main advantage of using microlens arrays for micropatterning surfaces is the possibility of fabricating a large number of identical structures simultaneously, leading to a highly efficient process. In order to study the capabilities of the microlens fabricated for microstructuring materials, identical structures and arrays of holes were fabricated over a variety of materials, such us, stainless steel, polymer and ceramic. The minimum diameter of the individual microstructure generated at surface is 5 μm. Different nanosecond lasers operating at Infrared, Green and UV were used. The topography and morphology of the elements obtained were determined using a confocal microscope SENSOFAR 2300 Plμ.

  3. Single-step laser-based fabrication and patterning of cell-encapsulated alginate microbeads

    International Nuclear Information System (INIS)

    Kingsley, D M; Dias, A D; Corr, D T; Chrisey, D B

    2013-01-01

    Alginate can be used to encapsulate mammalian cells and for the slow release of small molecules. Packaging alginate as microbead structures allows customizable delivery for tissue engineering, drug release, or contrast agents for imaging. However, state-of-the-art microbead fabrication has a limited range in achievable bead sizes, and poor control over bead placement, which may be desired to localize cellular signaling or delivery. Herein, we present a novel, laser-based method for single-step fabrication and precise planar placement of alginate microbeads. Our results show that bead size is controllable within 8%, and fabricated microbeads can remain immobilized within 2% of their target placement. Demonstration of this technique using human breast cancer cells shows that cells encapsulated within these microbeads survive at a rate of 89.6%, decreasing to 84.3% after five days in culture. Infusing rhodamine dye into microbeads prior to fluorescent microscopy shows their 3D spheroidal geometry and the ability to sequester small molecules. Microbead fabrication and patterning is compatible with conventional cellular transfer and patterning by laser direct-write, allowing location-based cellular studies. While this method can also be used to fabricate microbeads en masse for collection, the greatest value to tissue engineering and drug delivery studies and applications lies in the pattern registry of printed microbeads. (paper)

  4. Repurposing mainstream CNC machine tools for laser-based additive manufacturing

    Science.gov (United States)

    Jones, Jason B.

    2016-04-01

    The advent of laser technology has been a key enabler for industrial 3D printing, known as Additive Manufacturing (AM). Despite its commercial success and unique technical capabilities, laser-based AM systems are not yet able to produce parts with the same accuracy and surface finish as CNC machining. To enable the geometry and material freedoms afforded by AM, yet achieve the precision and productivity of CNC machining, hybrid combinations of these two processes have started to gain traction. To achieve the benefits of combined processing, laser technology has been integrated into mainstream CNC machines - effectively repurposing them as hybrid manufacturing platforms. This paper reviews how this engineering challenge has prompted beam delivery innovations to allow automated changeover between laser processing and machining, using standard CNC tool changers. Handling laser-processing heads using the tool changer also enables automated change over between different types of laser processing heads, further expanding the breadth of laser processing flexibility in a hybrid CNC. This paper highlights the development, challenges and future impact of hybrid CNCs on laser processing.

  5. Progress in 41Ca ultratrace determination by diode-laser-based RIMS

    International Nuclear Information System (INIS)

    Mueller, P.; Blaum, K.; Diel, S.; Geppert, Ch.; Wendt, K.; Bushaw, B.A.; Trautmann, N.

    2001-01-01

    We report on progress in development and application of 41 Ca ultratrace determination by diode-laser-based RIMS. Applications include biomedical isotope-tracer studies of human calcium kinetics, cosmochemical investigations of meteorites, environmental dosimetry and radiodating. Depending on the application, 41 Ca needs to be determined at isotopic abundance in the range of 10 -9 to 10 -15 relative to the major stable isotope 40 Ca. We use either a double- or triple-resonance excitation scheme and subsequent non-resonant photoionization of calcium atoms in a collimated atomic beam. All resonant steps are excited with narrow bandwidth extended cavity diode lasers, non-resonant photo-ionization is attained with either an argon ion laser or a CO 2 laser. The resulting photo-ions are detected with a quadrupole mass spectrometer. With double-resonance excitation, the optical isotopic selectivity for 41 Ca against 40 Ca is 2x10 4 , while the triple-resonance scheme provides optical selectivity of more than 10 9 . By adding the third resonant step, overall detection efficiency increases from 1x10 -6 to 5x10 -5 and the detection limit for relative 41 Ca abundance improves from 5x10 -10 to 2x10 -13 . Both schemes have been applied to various sample types and accuracy and reproducibility of the resulting 41 Ca/ 40 Ca isotope ratios have been determined to be better than 5%

  6. Tunable multi-wavelength polymer laser based on a triangular-lattice photonic crystal structure

    International Nuclear Information System (INIS)

    Huang, Wenbin; Pu, Donglin; Qiao, Wen; Wan, Wenqiang; Liu, Yanhua; Ye, Yan; Wu, Shaolong; Chen, Linsen

    2016-01-01

    A continuously tunable multi-wavelength polymer laser based on a triangular-lattice photonic crystal cavity is demonstrated. The triangular-lattice resonator was initially fabricated through multiple interference exposure and was then replicated into a low refractive index polymer via UV-nanoimprinting. The blend of a blue-emitting conjugated polymer and a red-emitting one was used as the gain medium. Three periods in the scalene triangular-lattice structure yield stable tri-wavelength laser emission (625.5 nm, 617.4 nm and 614.3 nm) in six different directions. A uniformly aligned liquid crystal (LC) layer was incorporated into the cavity as the top cladding layer. Upon heating, the orientation of LC molecules and thus the effective refractive index of the lasing mode changes which continuously shifts the lasing wavelength. A maximum tuning range of 12.2 nm was observed for the lasing mode at 625.5 nm. This tunable tri-wavelength polymer laser is simple constructed and cost-effective. It may find application in the fields of biosensors and photonic integrated circuits. (paper)

  7. Development and characterization of a laser-based hard x-ray source

    International Nuclear Information System (INIS)

    Tillman, C.

    1996-11-01

    A laser-produced plasma was generated by focusing 100 fs laser pulses, with an energy of 150 mJ, onto metal targets. The laser intensity was expected to reach 10 17 W/cm -2 . Radiation was emitted from the created plasma, with photon energies up to the MeV region. The laser-based X-ray source was optimized, with the purpose of making it a realistic source of hard X-rays (>10 keV). Dedicated equipment was developed for efficient generation and utilization of the hard X-rays. The X-ray source was characterized with respect to its spatial extent and the X-ray yield. Measurements were made of the spectral distribution, by the use of single-photon-counting detectors in different geometries, crystal spectrometers and dose measurements in combination with absorption filters. Ablation of the target material in the laser produced plasma was investigated. Imaging applications have been demonstrated, including ultrafast (picosecond) X-ray imaging, magnification imaging of up to x80, differential imaging in the spectral domain, and imaging of various biological and technical objects. The biological response of ultra-intense X-ray pulses was assessed in cell-culture exposures. The results indicate that the biological response from ultra-intense X-ray exposures is similar to the response with conventional X-ray tubes. 82 refs., 14 figs

  8. A Laser-Based Measuring System for Online Quality Control of Car Engine Block

    Directory of Open Access Journals (Sweden)

    Xing-Qiang Li

    2016-11-01

    Full Text Available For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs, which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.

  9. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    International Nuclear Information System (INIS)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-01-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected. (papers)

  10. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    Science.gov (United States)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-06-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected.

  11. Isotopic imaging via nuclear resonance fluorescence with laser-based Thomson radiation

    Science.gov (United States)

    Barty, Christopher P. J. [Hayward, CA; Hartemann, Frederic V [San Ramon, CA; McNabb, Dennis P [Alameda, CA; Pruet, Jason A [Brentwood, CA

    2009-07-21

    The present invention utilizes novel laser-based, high-brightness, high-spatial-resolution, pencil-beam sources of spectrally pure hard x-ray and gamma-ray radiation to induce resonant scattering in specific nuclei, i.e., nuclear resonance fluorescence. By monitoring such fluorescence as a function of beam position, it is possible to image in either two dimensions or three dimensions, the position and concentration of individual isotopes in a specific material configuration. Such methods of the present invention material identification, spatial resolution of material location and ability to locate and identify materials shielded by other materials, such as, for example, behind a lead wall. The foundation of the present invention is the generation of quasimonochromatic high-energy x-ray (100's of keV) and gamma-ray (greater than about 1 MeV) radiation via the collision of intense laser pulses from relativistic electrons. Such a process as utilized herein, i.e., Thomson scattering or inverse-Compton scattering, produces beams having diameters from about 1 micron to about 100 microns of high-energy photons with a bandwidth of .DELTA.E/E of approximately 10E.sup.-3.

  12. Laser-based sensor for a coolant leak detection in a nuclear reactor

    Science.gov (United States)

    Kim, T.-S.; Park, H.; Ko, K.; Lim, G.; Cha, Y.-H.; Han, J.; Jeong, D.-Y.

    2010-08-01

    Currently, the nuclear industry needs strongly a reliable detection system to continuously monitor a coolant leak during a normal operation of reactors for the ensurance of nuclear safety. In this work, we propose a new device for the coolant leak detection based on tunable diode laser spectroscopy (TDLS) by using a compact diode laser. For the feasibility experiment, we established an experimental setup consisted of a near-IR diode laser with a wavelength of about 1392 nm, a home-made multi-pass cell and a sample injection system. The feasibility test was performed for the detection of the heavy water (D2O) leaks which can happen in a pressurized heavy water reactor (PWHR). As a result, the device based on the TDLS is shown to be operated successfully in detecting a HDO molecule, which is generated from the leaked heavy water by an isotope exchange reaction between D2O and H2O. Additionally, it is suggested that the performance of the new device, such as sensitivity and stability, can be improved by adapting a cavity enhanced absorption spectroscopy and a compact DFB diode laser. We presume that this laser-based leak detector has several advantages over the conventional techniques currently employed in the nuclear power plant, such as radiation monitoring, humidity monitoring and FT-IR spectroscopy.

  13. Laser-Based Surface Modification of Microstructure for Carbon Fiber-Reinforced Plastics

    Science.gov (United States)

    Yang, Wenfeng; Sun, Ting; Cao, Yu; Li, Shaolong; Liu, Chang; Tang, Qingru

    2018-05-01

    Bonding repair is a powerful feature of carbon fiber-reinforced plastics (CFRP). Based on the theory of interface bonding, the interface adhesion strength and reliability of the CFRP structure will be directly affected by the microscopic features of the CFRP surface, including the microstructure, physical, and chemical characteristics. In this paper, laser-based surface modification was compared to Peel-ply, grinding, and polishing to comparatively evaluate the surface microstructure of CFRP. The surface microstructure, morphology, fiber damage, height and space parameters were investigated by scanning electron microscopy (SEM) and laser confocal microscopy (LCM). Relative to the conventional grinding process, laser modification of the CFRP surface can result in more uniform resin removal and better processing control and repeatability. This decreases the adverse impact of surface fiber fractures and secondary damage. The surface properties were significantly optimized, which has been reflected such things as the obvious improvement of surface roughness, microstructure uniformity, and actual area. The improved surface microstructure based on laser modification is more conducive to interface bonding of CFRP structure repair. This can enhance the interfacial adhesion strength and reliability of repair.

  14. Widely-duration-tunable nanosecond pulse Nd:YVO4 laser based on double Pockels cells

    Science.gov (United States)

    He, Li-Jiao; Liu, Ke; Bo, Yong; Wang, Xiao-Jun; Yang, Jing; Liu, Zhao; Zong, Qing-Shuang; Peng, Qin-Jun; Cui, Da-Fu; Xu, Zu-Yan

    2018-05-01

    The development of duration-tunable pulse lasers with constant output power is important for scientific research and materials processing. We present a widely-duration-tunable nanosecond (ns) pulse Nd:YVO4 laser based on double Pockels cells (PCs), i.e. inserting an extra PC into a conventional electro-optic Q-switched cavity dumped laser resonator. Under the absorbed pump power of 24.9 W, the pulse duration is adjustable from 31.9 ns to 5.9 ns by changing the amplitude of the high voltage on the inserted PC from 1100 V to 4400 V at the pulse repetition rate of 10 kHz. The corresponding average output power is almost entirely maintained in the range of 3.5–4.1 W. This represents more than three times increase in pulse duration tunable regime and average power compared to previously reported results for duration-tunable ns lasers. The laser beam quality factor was measured to be M 2  <  1.18.

  15. High-precision diode-laser-based temperature measurement for air refractive index compensation.

    Science.gov (United States)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppä, Jeremias; Lassila, Antti

    2011-11-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement. © 2011 Optical Society of America

  16. High-precision diode-laser-based temperature measurement for air refractive index compensation

    International Nuclear Information System (INIS)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppae, Jeremias; Lassila, Antti

    2011-01-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

  17. Multi-kW single fiber laser based on an extra large mode area fiber design

    Science.gov (United States)

    Langner, Andreas; Such, Mario; Schötz, Gerhard; Just, Florian; Leich, Martin; Schwuchow, Anka; Grimm, Stephan; Zimer, Hagen; Kozak, Marcin; Wedel, Björn; Rehmann, Georg; Bachert, Charley; Krause, Volker

    2012-02-01

    The quality of Yb-doped fused bulk silica produced by sintering of Yb-doped fused silica granulates has improved greatly in the past five years [1 - 4]. In particular, the refractive index and doping level homogeneity of such materials are excellent and we achieved excellent background fiber attenuation of the active core material down to about 20 dB/km at 1200 nm. The improvement of the Yb-doped fused bulk silica has enabled the development of multi-kW fiber laser systems based on a single extra large multimode laser fiber (XLMA fiber). When a single active fiber is used in combination with the XLMA multimode fiber of 1200 μm diameter simple and robust high power fiber laser setups without complex fiber coupling and fiber combiner systems become possible. In this papper, we will discuss in detail the development of the core material based on Yb-doped bulk silica and the characterization of Yb-doped fibers with different core compositions. We will also report on the excellent performance of a 4 kW fiber laser based on a single XLMA-fiber and show the first experimental welding results of steel sheets achieved with such a laser.

  18. Laser Based Color Film Recorder System With GaAs Microlaser

    Science.gov (United States)

    Difrancesco, David J.

    1989-07-01

    In 1984 Pixar's research and development group built and applied to the motion-picture arts at Lucasfilm's ILM facility a three color laser based film scanner/recorder system. The digital film printer is capable of reading and writing 35mm film formats on a variety of film stocks. The system has been used in award-winning special-effects work, and has been operated in a normal production environment since that time. The primary objective was to develop a full color high resolution system, free from scan artifacts, enabling traditionally photographed motion-picture film to be inter-cut with digital raster image photography. Its use is applied to the art of blue-screen traveling-matte cinematography for motion pic-ture special effects. The system was designed using the Pixar Image Computer and conventional gas laser technology as the illumination source. This paper will discuss recent experimental work in the application of GaAs microlaser technology to a digital film printing system of the future.

  19. Development and characterization of a laser-based hard x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Tillman, C.

    1996-11-01

    A laser-produced plasma was generated by focusing 100 fs laser pulses, with an energy of 150 mJ, onto metal targets. The laser intensity was expected to reach 10{sup 17} W/cm{sup -2}. Radiation was emitted from the created plasma, with photon energies up to the MeV region. The laser-based X-ray source was optimized, with the purpose of making it a realistic source of hard X-rays (>10 keV). Dedicated equipment was developed for efficient generation and utilization of the hard X-rays. The X-ray source was characterized with respect to its spatial extent and the X-ray yield. Measurements were made of the spectral distribution, by the use of single-photon-counting detectors in different geometries, crystal spectrometers and dose measurements in combination with absorption filters. Ablation of the target material in the laser produced plasma was investigated. Imaging applications have been demonstrated, including ultrafast (picosecond) X-ray imaging, magnification imaging of up to x80, differential imaging in the spectral domain, and imaging of various biological and technical objects. The biological response of ultra-intense X-ray pulses was assessed in cell-culture exposures. The results indicate that the biological response from ultra-intense X-ray exposures is similar to the response with conventional X-ray tubes. 82 refs., 14 figs.

  20. Laser-based pedestrian tracking in outdoor environments by multiple mobile robots.

    Science.gov (United States)

    Ozaki, Masataka; Kakimuma, Kei; Hashimoto, Masafumi; Takahashi, Kazuhiko

    2012-10-29

    This paper presents an outdoors laser-based pedestrian tracking system using a group of mobile robots located near each other. Each robot detects pedestrians from its own laser scan image using an occupancy-grid-based method, and the robot tracks the detected pedestrians via Kalman filtering and global-nearest-neighbor (GNN)-based data association. The tracking data is broadcast to multiple robots through intercommunication and is combined using the covariance intersection (CI) method. For pedestrian tracking, each robot identifies its own posture using real-time-kinematic GPS (RTK-GPS) and laser scan matching. Using our cooperative tracking method, all the robots share the tracking data with each other; hence, individual robots can always recognize pedestrians that are invisible to any other robot. The simulation and experimental results show that cooperating tracking provides the tracking performance better than conventional individual tracking does. Our tracking system functions in a decentralized manner without any central server, and therefore, this provides a degree of scalability and robustness that cannot be achieved by conventional centralized architectures.

  1. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  2. Indirect taxes on food in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Denize Mirian da Silva

    2013-12-01

    Full Text Available The objective of this paper is to estimate the indirect tax burden on food for ten income classes, based on income and household total expenditure in southern Brazil. Thus it can be seen as indirect taxes on foods affect the monetary income and consumption pattern of households. To reach the objectives proposed, will be used the Pintos-Payeras (2008 model. The database iscomposed by microdata from the Household Budgeting Survey (POF 2008-2009 and the tax regulations of the country and the southern states of Brazil. The results show that indirect taxes on food in Southern Brazil is regressive when based on income and expenditure of household , ie , the poorest people pay proportionately more taxes and have their consumption pattern highest taxed ICMS (Brazilian value added tax is the tax that contributes most to the regressivity.

  3. Ballistic fractures: indirect fracture to bone.

    Science.gov (United States)

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  4. Indirect Comorbidity in Childhood and Adolescence

    Directory of Open Access Journals (Sweden)

    William eCopeland

    2013-11-01

    Full Text Available Objective: Comorbidity between psychiatric disorders is common, but pairwise associations between two disorders may be explained by the presence of other diagnoses that are associated with both disorders or indirect comorbidity. Method: Comorbidities of common childhood psychiatric disorders were tested in three community samples of children ages 6 to 17 (8931 observations of 2965 subjects. Psychiatric disorder status in all three samples was assessed with the Child and Adolescent Psychiatric Assessment. Indirect comorbidity was defined as A-B associations that decreased from significance to nonsignificance after adjusting for other disorders. Results: All tested childhood psychiatric disorders were positively associated in bivariate analyses. After adjusting for comorbidities, many ssociations involving a behavioral disorder and an emotional disorder were attenuated suggesting indirect comorbidity. Generalized anxiety and depressive disorders displayed a very high level of overlap (adjusted OR=37.9. All analyses were rerun with depressive disorders grouped with generalized anxiety disorder in a single distress disorders category. In these revised models, all associations between and emotional disorder and a behavior disorder met our criteria for indirect comorbidity except for the association of oppositional defiant disorder with distress disorders (OR=11.3. Follow-up analyses suggested that the indirect associations were primarily accounted for by oppositional defiant disorder and the distress disorder category. There was little evidence of either sex differences or differences by developmental period Conclusions: After accounting for the overlap between depressive disorders with generalized anxiety disorder, direct comorbidity between emotional and behavioral disorders was uncommon. When there was evidence of indirect comorbidity, ODD and distress disorders were the key intermediary diagnoses accounting for the apparent associations.

  5. Indirect effects in dual radiation action

    International Nuclear Information System (INIS)

    Zaider, M.; Rossi, H.H.

    1988-01-01

    The basic aim in this paper is to establish the link between indirect effects of radiation action and the spatial distribution of radicals at the time of energy deposition as well as throughout subsequent diffusion and interaction. The fact that radicals diffuse for a finite distance before damaging a biomolecule has dramatic effects on their subsequent probability to result in lesions. Thus at very low DMSO concentrations, where p = 0.5, one expects - all other things being equal - some 75% of the lesions to result from indirect or semidirect lesions. The number calculated here is lower (15%), a direct result of the fact that such lesions involve proximity functions modulated by diffusion. At higher DMSO concentrations this percentage becomes progressively smaller, as expected. It appears thus that for low-LET radiation, the relative amount of indirect damage in single tracks (also termed intratrack or single events) action is very small. By contrast, intertrack (or two-event) contributions will have the ratio between direct and (indirect + semidirect) contributions given by p 2 /(1-p 2 ). The reason for this is that sublesions from different tracks are uniformly distributed throughout the cell nucleus; their probability of interaction should not depend on any previous diffusional processes. For the example given above (p = 0.5) they do expect 65% of intertrack (two-hit) lesions to have resulted from indirect or semidirect mechanisms. This contrast between the almost exclusively direct character of intratrack lesions and the dominant role of indirect action in intertrack lesions produced by low-LET radiation is an important conclusion of this study

  6. Investigating hydrogen peroxide in rainwater of a typical midsized city in tropical Brazil using a novel application of a fluorometric method

    Science.gov (United States)

    Scaramboni, C.; Crispim, C. P.; Toledo, J. C.; Campos, M. L. A. M.

    2018-03-01

    This work investigates the effect of public policies related to vehicle emissions on the lower tropospheric concentrations of H2O2 in a typical midsized city in tropical Brazil. The concentrations of H2O2, SO42-, and NO3- in rainwater samples were determined from 2014 to 2017 in the municipality of Ribeirão Preto in São Paulo State. A fluorometric method, based on the formation of a highly fluorescent product (2‧,7‧-dichlorofluorescein, DCF), was adapted and optimized for the measurement of H2O2 in natural water samples including seawater. The method was highly specific, accurate and sensitive (LOD = 2 nmol L-1). Its main advantage compared to others, was that the fluorophore remained stable for at least 48 h, offering a longer time interval in which to perform the analysis and therefore facilitating fieldwork. Concentrations of H2O2 in rainwater ranged from 5.8 to 96 μmol L-1, with VWM of 28.6 ± 1.4 μmol L-1 (n = 77). Solar radiation appeared to have a greater impact on production than on consumption of H2O2. The annual VWM concentrations of H2O2 in rainwater were negatively correlated with sulfate (at pH important factors affecting the concentration of H2O2 in the atmosphere. This work expands the current records available for the Southern Hemisphere, where there is a considerable paucity of information regarding temporal production and loss of atmospheric H2O2.

  7. Fluorometric determination of aluminium (III) and cadmium (II) by solvent extraction of the ternary complex composed of metal ion, 8-hydroxy-5-quinolinesulfonic acid, and methyltrioctylammonium ion

    International Nuclear Information System (INIS)

    Kondoh, Yukihiro; Kataoka, Masamitsu; Kambara, Tomihito

    1982-01-01

    A fluorometric micro determination of aluminium (III) and cadmium (II) using the formation of metal-8-hydroxy-5-quinolinesulfonic acid-capriquat (methyltrioctylammonium) ternary complex is described. These complexes are easily extracted into chloroform phase and the extract emits a strong fluorescence. Spectra of aluminium (III) and cadmium (II) ternary complexes have the excitation maximum at 396 nm and 400 nm, and emission maximum at 501 nm and 524 nm, respectively. Fluorescence intensity of the aluminium (III) and cadmium (II) ternary complexes extracted into chloroform showed the constant and maximum values in the pH range of aqueous phase from 5.3 to 8.5 and 8.1 to 8.5, respectively. The calibration curves for aluminium (III) and cadmium (II) show good proportionality int the concentration range from 0.5 to 5.0 and 1.0 to 50.0 μg, respectively. The relative standard deviation observed with four measurements was found to be 1.8% for 0.5 μg of aluminium (III) and 1.1% for 10.0 μg of cadmium (II). The effect of diverse ions is studied and a 25-fold amount of Cu(II), Ni(II), Fe(II), Fe(III) in weight gave errors, however, the interferences were easily eliminated by the addition of appropriate masking agent. In the determination of cadmium (II), an equal amount of Co(II), Ni(II), Mn(II), Fe(III) and twice amount of Al(III) gave negative errors, however, the interference of Fe(III) and Al(III) were also eliminated as above. (author)

  8. Global indirect aerosol effects: a review

    Directory of Open Access Journals (Sweden)

    U. Lohmann

    2005-01-01

    Full Text Available Aerosols affect the climate system by changing cloud characteristics in many ways. They act as cloud condensation and ice nuclei, they may inhibit freezing and they could have an influence on the hydrological cycle. While the cloud albedo enhancement (Twomey effect of warm clouds received most attention so far and traditionally is the only indirect aerosol forcing considered in transient climate simulations, here we discuss the multitude of effects. Different approaches how the climatic implications of these aerosol effects can be estimated globally as well as improvements that are needed in global climate models in order to better represent indirect aerosol effects are discussed in this paper.

  9. Biomass Indirect Liquefaction Strategy Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-07-01

    This report is based on the proceedings of the U.S. Department of Energy Bioenergy Technologies Office Biomass Indirect Liquefaction Strategy Workshop. The workshop, held March 20–21, 2014, in Golden, Colorado, discussed and detailed the research and development needs for biomass indirect liquefaction. Discussions focused on pathways that convert biomass-based syngas (or any carbon monoxide, hydrogen gaseous stream) to liquid intermediates (alcohols or acids) and further synthesize those intermediates to liquid hydrocarbons that are compatible as either a refinery feed or neat fuel.

  10. The power of indirect social ties

    OpenAIRE

    Zuo, Xiang; Blackburn, Jeremy; Kourtellis, Nicolas; Skvoretz, John; Iamnitchi, Adriana

    2014-01-01

    While direct social ties have been intensely studied in the context of computer-mediated social networks, indirect ties (e.g., friends of friends) have seen little attention. Yet in real life, we often rely on friends of our friends for recommendations (of good doctors, good schools, or good babysitters), for introduction to a new job opportunity, and for many other occasional needs. In this work we attempt to 1) quantify the strength of indirect social ties, 2) validate it, and 3) empiricall...

  11. Indirect methods for wake potential integration

    International Nuclear Information System (INIS)

    Zagorodnov, I.

    2006-05-01

    The development of the modern accelerator and free-electron laser projects requires to consider wake fields of very short bunches in arbitrary three dimensional structures. To obtain the wake numerically by direct integration is difficult, since it takes a long time for the scattered fields to catch up to the bunch. On the other hand no general algorithm for indirect wake field integration is available in the literature so far. In this paper we review the know indirect methods to compute wake potentials in rotationally symmetric and cavity-like three dimensional structures. For arbitrary three dimensional geometries we introduce several new techniques and test them numerically. (Orig.)

  12. Development of an indirect spectrophotometric method for ...

    African Journals Online (AJOL)

    A simple and rapid indirect spectrophotometric method for determination of ... of the colored product was measured at 405 nm and pH 3 against a reagent blank. ... The limit of detection and quantification were found to be 0.20±0.03 and ...

  13. Indirect processes in electron-ion scattering

    International Nuclear Information System (INIS)

    Bottcher, C.; Griffin, D.C.; Pindzola, M.S.; Phaneuf, R.A.

    1983-10-01

    A summary is given of an informal workshop held at Oak Ridge National Laboratory on June 22-23, 1983, in which the current status of theoretical calculations of indirect processes in electron-ion scattering was reviewed. Processes of particular interest in astrophysical and fusion plasmas were emphasized. Topics discussed include atomic structure effects, electron-impact ionization, and dielectronic recombination

  14. Indirect effects of recreation on wildlife

    Science.gov (United States)

    David N. Cole; Peter B. Landres

    1995-01-01

    Most of this book focuses on direct impacts to wildlife that result from contact with people. The purpose of our chapter is to provide a broad overview of the indirect influences that recreation has on wildlife. Recreational activities can change the habitat of an animal. This, in turn, affects the behavior, survival, reproduction, and distribution of individuals....

  15. 46 CFR 154.1720 - Indirect refrigeration.

    Science.gov (United States)

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Special Design and Operating Requirements § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene...

  16. Indirect processes in electron-ion scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bottcher, C.; Griffin, D.C.; Pindzola, M.S.; Phaneuf, R.A.

    1983-10-01

    A summary is given of an informal workshop held at Oak Ridge National Laboratory on June 22-23, 1983, in which the current status of theoretical calculations of indirect processes in electron-ion scattering was reviewed. Processes of particular interest in astrophysical and fusion plasmas were emphasized. Topics discussed include atomic structure effects, electron-impact ionization, and dielectronic recombination.

  17. 27 CFR 6.32 - Indirect interest.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Interest in Retail Property § 6.32 Indirect interest. Industry member interest in retail property includes any interest acquired by corporate officials, partners, employees or other representatives of the industry member. Any interest in retail property...

  18. 27 CFR 6.26 - Indirect interest.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Interest in Retail License § 6.26 Indirect interest. Industry member interest in retail licenses includes any interest acquired by corporate officials, partners, employees or other representatives of the industry member. Any interest in a retail license...

  19. Indirect Costs: Daily Bread, Cake, or Cracker.

    Science.gov (United States)

    Lucas, Robert A.

    1988-01-01

    The tradition of negotiating indirect costs in grants should be abandoned, and research administrators should instead offer different levels of service depending on what the sponsor wants to spend. Three levels of overhead rate are suggested (super, regular, and economy) and their corresponding levels of service are defined. (MSE)

  20. Epidemic spreading through direct and indirect interactions.

    Science.gov (United States)

    Ganguly, Niloy; Krueger, Tyll; Mukherjee, Animesh; Saha, Sudipta

    2014-09-01

    In this paper we study the susceptible-infected-susceptible epidemic dynamics, considering a specialized setting where popular places (termed passive entities) are visited by agents (termed active entities). We consider two types of spreading dynamics: direct spreading, where the active entities infect each other while visiting the passive entities, and indirect spreading, where the passive entities act as carriers and the infection is spread via them. We investigate in particular the effect of selection strategy, i.e., the way passive entities are chosen, in the spread of epidemics. We introduce a mathematical framework to study the effect of an arbitrary selection strategy and derive formulas for prevalence, extinction probabilities, and epidemic thresholds for both indirect and direct spreading. We also obtain a very simple relationship between the extinction probability and the prevalence. We pay special attention to preferential selection and derive exact formulas. The analysis reveals that an increase in the diversity in the selection process lowers the epidemic thresholds. Comparing the direct and indirect spreading, we identify regions in the parameter space where the prevalence of the indirect spreading is higher than the direct one.

  1. Indirect Determination of the sigma - omega

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Brincker, Rune

    . The beams where submitted to three-point bending in a servo-controlled materials testing system. The constitutive parameters in the fictitious crack model were determined by using three different indirect techniques, which are described and evaluated. The results show that the fracture energy is increasing...

  2. Comprehension Process of Second Language Indirect Requests.

    Science.gov (United States)

    Takahashi, Satomi; Roitblat, Herbert L.

    1994-01-01

    Examines the comprehension of English conventional indirect requests by native English speakers and Japanese learners of English. Subjects read stories inducing either a conventional or a literal interpretation of a priming sentence. Results suggest that both native and nonnative speakers process both meanings of an ambiguous conventional request.…

  3. 48 CFR 31.203 - Indirect costs.

    Science.gov (United States)

    2010-10-01

    ... fiscal year used for financial reporting purposes in accordance with generally accepted accounting... contract or other work, indirect costs are those remaining to be allocated to intermediate or two or more... basis of the benefits accruing to intermediate and final cost objectives. When substantially the same...

  4. Scene independent real-time indirect illumination

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Christensen, Niels Jørgen; Falster, Peter

    2005-01-01

    A novel method for real-time simulation of indirect illumination is presented in this paper. The method, which we call Direct Radiance Mapping (DRM), is based on basal radiance calculations and does not impose any restrictions on scene geometry or dynamics. This makes the method tractable for rea...

  5. Demonstration of a diode-laser-based high spectral resolution lidar (HSRL) for quantitative profiling of clouds and aerosols.

    Science.gov (United States)

    Hayman, Matthew; Spuler, Scott

    2017-11-27

    We present a demonstration of a diode-laser-based high spectral resolution lidar. It is capable of performing calibrated retrievals of aerosol and cloud optical properties at a 150 m range resolution with less than 1 minute integration time over an approximate range of 12 km during day and night. This instrument operates at 780 nm, a wavelength that is well established for reliable semiconductor lasers and detectors, and was chosen because it corresponds to the D2 rubidium absorption line. A heated vapor reference cell of isotopic rubidium 87 is used as an effective and reliable aerosol signal blocking filter in the instrument. In principle, the diode-laser-based high spectral resolution lidar can be made cost competitive with elastic backscatter lidar systems, yet delivers a significant improvement in data quality through direct retrieval of quantitative optical properties of clouds and aerosols.

  6. Development of laser-based technology for the routine first wall diagnostic on the tokamak EAST: LIBS and LIAS

    Science.gov (United States)

    Hu, Z.; Gierse, N.; Li, C.; Liu, P.; Zhao, D.; Sun, L.; Oelmann, J.; Nicolai, D.; Wu, D.; Wu, J.; Mao, H.; Ding, F.; Brezinsek, S.; Liang, Y.; Ding, H.; Luo, G.; Linsmeier, C.; EAST Team

    2017-12-01

    A laser based method combined with spectroscopy, such as laser-induced breakdown spectroscopy (LIBS) and laser-induced ablation spectroscopy (LIAS), is a promising technology for plasma-wall interaction studies. In this work, we report the development of in situ laser-based diagnostics (LIBS and LIAS) for the assessment of static and dynamic fuel retention on the first wall without removing the tiles between and during plasma discharges in the Experimental Advanced Superconducting Tokamak (EAST). The fuel retention on the first wall was measured after different wall conditioning methods and daily plasma discharges by in situ LIBS. The result indicates that the LIBS can be a useful tool to predict the wall condition in EAST. With the successful commissioning of a refined timing system for LIAS, an in situ approach to investigate fuel retention is proposed.

  7. Status and trends of short pulse generation using mode-locked lasers based on advanced quantum-dot active media

    International Nuclear Information System (INIS)

    Shi, L W; Chen, Y H; Xu, B; Wang, Z C; Jiao, Y H; Wang, Z G

    2007-01-01

    In this review, the potential of mode-locked lasers based on advanced quantum-dot (QD) active media to generate short optical pulses is analysed. A comprehensive review of experimental and theoretical work on related aspects is provided, including monolithic-cavity mode-locked QD lasers and external-cavity mode-locked QD lasers, as well as mode-locked solid-state and fibre lasers based on QD semiconductor saturable absorber mirrors. Performance comparisons are made for state-of-the-art experiments. Various methods for improving important characteristics of mode-locked pulses such as pulse duration, repetition rate, pulse power, and timing jitter through optimization of device design parameters or mode-locking methods are addressed. In addition, gain switching and self-pulsation of QD lasers are also briefly reviewed, concluding with the summary and prospects. (topical review)

  8. Two distinct neural mechanisms underlying indirect reciprocity.

    Science.gov (United States)

    Watanabe, Takamitsu; Takezawa, Masanori; Nakawake, Yo; Kunimatsu, Akira; Yamasue, Hidenori; Nakamura, Mitsuhiro; Miyashita, Yasushi; Masuda, Naoki

    2014-03-18

    Cooperation is a hallmark of human society. Humans often cooperate with strangers even if they will not meet each other again. This so-called indirect reciprocity enables large-scale cooperation among nonkin and can occur based on a reputation mechanism or as a succession of pay-it-forward behavior. Here, we provide the functional and anatomical neural evidence for two distinct mechanisms governing the two types of indirect reciprocity. Cooperation occurring as reputation-based reciprocity specifically recruited the precuneus, a region associated with self-centered cognition. During such cooperative behavior, the precuneus was functionally connected with the caudate, a region linking rewards to behavior. Furthermore, the precuneus of a cooperative subject had a strong resting-state functional connectivity (rsFC) with the caudate and a large gray matter volume. In contrast, pay-it-forward reciprocity recruited the anterior insula (AI), a brain region associated with affective empathy. The AI was functionally connected with the caudate during cooperation occurring as pay-it-forward reciprocity, and its gray matter volume and rsFC with the caudate predicted the tendency of such cooperation. The revealed difference is consistent with the existing results of evolutionary game theory: although reputation-based indirect reciprocity robustly evolves as a self-interested behavior in theory, pay-it-forward indirect reciprocity does not on its own. The present study provides neural mechanisms underlying indirect reciprocity and suggests that pay-it-forward reciprocity may not occur as myopic profit maximization but elicit emotional rewards.

  9. Development of Laser Based Plasma Diagnostics for Fusion Research on NSTX-U

    Science.gov (United States)

    Barchfeld, Robert Adam

    plasma diagnostics. Plasma diagnostics collect data from fusion reactors in a number of different ways. Among these are far infrared (FIR) laser based systems. By probing a fusion plasma with FIR lasers, many properties can be measured, such as density and density fluctuations. This dissertation discusses the theory and design of two laser based diagnostic instruments: 1) the Far Infrared Tangential Interferometer and Polarimeter (FIReTIP) systems, and 2) the High-ktheta Scattering System. Both of these systems have been designed and fabricated at UC Davis for use on the National Spherical Torus Experiment - Upgrade (NSTX-U), located at Princeton Plasma Physics Laboratory (PPPL). These systems will aid PPPL scientists in fusion research. The FIReTIP system uses 119 ?m methanol lasers to pass through the plasma core to measure a chord averaged plasma density through interferometry. It can also measure the toroidal magnetic field strength by the way of polarimetery. The High-ktheta Scattering System uses a 693 GHz formic acid laser to measure electron scale turbulence. Through collective Thomson scattering, as the probe beam passes through the plasma, collective electron motion will scatter power to a receiver with the angle determined by the turbulence wavenumber. This diagnostic will measure ktheta from 7 to 40 cm-1 with a 4-channel receiver array. The High-ktheta Scattering system was designed to facilitate research on electron temperature gradient (ETG) modes, which are believed to be a major contributor to anomalous transport on NSTX-U. The design and testing of these plasma diagnostics are described in detail. There are a broad range of components detailed including: optically pumped gas FIR lasers, overmoded low loss waveguide, launching and receiving optical designs, quasi-optical mixers, electronics, and monitoring and control systems. Additionally, details are provided for laser maintenance, alignment techniques, and the fundamentals of nano-CNC-machining.

  10. Preparation of electrodes on cfrp composites with low contact resistance comprising laser-based surface pre-treatment

    KAUST Repository

    Almuhammadi, Khaled Hamdan

    2016-12-29

    Various examples are provided related to the preparation of electrodes on carbon fiber reinforced polymer (CFRP) composites with low contact resistance. Laser-based surface preparation can be used for bonding to CFRP composites. In one example, a method includes preparing a pretreated target area on a CFRP composite surface using laser pulsed irradiation and bonding an electrode to exposed fibers in the pretreated target area. The surface preparation can allow the electrode to have a low contact resistance with the CFRP composite.

  11. Real time detection of exhaled human breath using quantum cascade laser based sensor technology

    Science.gov (United States)

    Tittel, Frank K.; Lewicki, Rafal; Dong, Lei; Liu, Kun; Risby, Terence H.; Solga, Steven; Schwartz, Tim

    2012-02-01

    The development and performance of a cw, TE-cooled DFB quantum cascade laser based sensor for quantitative measurements of ammonia (NH3) and nitric oxide (NO) concentrations present in exhaled breath will be reported. Human breath contains ~ 500 different chemical species, usually at ultra low concentration levels, which can serve as biomarkers for the identification and monitoring of human diseases or wellness states. By monitoring NH3 concentration levels in exhaled breath a fast, non-invasive diagnostic method for treatment of patients with liver and kidney disorders, is feasible. The NH3 concentration measurements were performed with a 2f wavelength modulation quartz enhanced photoacoustic spectroscopy (QEPAS) technique, which is suitable for real time breath measurements, due to the fast gas exchange inside a compact QEPAS gas cell. A Hamamatsu air-cooled high heat load (HHL) packaged CW DFB-QCL is operated at 17.5°C, targeting the optimum interference free NH3 absorption line at 967.35 cm-1 (λ~10.34 μm), with ~ 20 mW of optical power. The sensor architecture includes a reference cell, filled with a 2000 ppmv NH3 :N2 mixture at 130 Torr, which is used for absorption line-locking. A minimum detection limit (1σ) for the line locked NH3 sensor is ~ 6 ppbv (with a 1σ 1 sec time resolution of the control electronics). This NH3 sensor was installed in late 2010 and is being clinically tested at St. Luke's Hospital in Bethlehem, PA.

  12. Automated laser-based barely visible impact damage detection in honeycomb sandwich composite structures

    International Nuclear Information System (INIS)

    Girolamo, D.; Yuan, F. G.; Girolamo, L.

    2015-01-01

    Nondestructive evaluation (NDE) for detection and quantification of damage in composite materials is fundamental in the assessment of the overall structural integrity of modern aerospace systems. Conventional NDE systems have been extensively used to detect the location and size of damages by propagating ultrasonic waves normal to the surface. However they usually require physical contact with the structure and are time consuming and labor intensive. An automated, contactless laser ultrasonic imaging system for barely visible impact damage (BVID) detection in advanced composite structures has been developed to overcome these limitations. Lamb waves are generated by a Q-switched Nd:YAG laser, raster scanned by a set of galvano-mirrors over the damaged area. The out-of-plane vibrations are measured through a laser Doppler Vibrometer (LDV) that is stationary at a point on the corner of the grid. The ultrasonic wave field of the scanned area is reconstructed in polar coordinates and analyzed for high resolution characterization of impact damage in the composite honeycomb panel. Two methodologies are used for ultrasonic wave-field analysis: scattered wave field analysis (SWA) and standing wave energy analysis (SWEA) in the frequency domain. The SWA is employed for processing the wave field and estimate spatially dependent wavenumber values, related to discontinuities in the structural domain. The SWEA algorithm extracts standing waves trapped within damaged areas and, by studying the spectrum of the standing wave field, returns high fidelity damage imaging. While the SWA can be used to locate the impact damage in the honeycomb panel, the SWEA produces damage images in good agreement with X-ray computed tomographic (X-ray CT) scans. The results obtained prove that the laser-based nondestructive system is an effective alternative to overcome limitations of conventional NDI technologies

  13. Diode-laser-based water vapor differential absorption lidar (DIAL) profiler evaluation

    Science.gov (United States)

    Spuler, S.; Weckwerth, T.; Repasky, K. S.; Nehrir, A. R.; Carbone, R.

    2012-12-01

    We are in the process of evaluating the performance of an eye-safe, low-cost, diode-laser-based, water vapor differential absorption lidar (DIAL) profiler. This class of instrument may be capable of providing continuous water vapor and aerosol backscatter profiles at high vertical resolution in the atmospheric boundary layer (ABL) for periods of months to years. The technology potentially fills a national long term observing facility gap and could greatly benefit micro- and meso-meteorology, water cycle, carbon cycle and, more generally, biosphere-hydrosphere-atmosphere interaction research at both weather and climate variability time scales. For the evaluation, the Montana State University 3rd generation water vapor DIAL was modified to enable unattended operation for a period of several weeks. The performance of this V3.5 version DIAL was tested at MSU and NCAR in June and July of 2012. Further tests are currently in progress with Howard University at Beltsville, Maryland; and with the National Weather Service and Oklahoma University at Dallas/Fort Worth, Texas. The presentation will include a comparison of DIAL profiles against meteorological "truth" at the aforementioned locations including: radiosondes, Raman lidars, microwave and IR radiometers, AERONET and SUOMINET systems. Instrument reliability, uncertainty, systematic biases, detection height statistics, and environmental complications will be evaluated. Performance will be judged in the context of diverse scientific applications that range from operational weather prediction and seasonal climate variability, to more demanding climate system process studies at the land-canopy-ABL interface. Estimating the extent to which such research and operational applications can be satisfied with a low cost autonomous network of similar instruments is our principal objective.

  14. Safeguard Application Options for the Laser-Based Item Monitoring System (LBIMS)

    International Nuclear Information System (INIS)

    Laughter, Mark D

    2008-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) are developing a Laser-Based Item Monitoring System (LBIMS) for advanced safeguards at nuclear facilities. LBIMS uses a low-power laser transceiver to monitor the presence and position of items with retroreflective tags. The primary advantages of LBIMS are its scalability to continuously monitor a wide range of items, its ability to operate unattended, its low cost of implementation, and its inherent information security due to its line-of-sight and non-broadcasting operation. The primary proposed safeguard application of LBIMS is described in its name: item monitoring. LBIMS could be implemented in a storage area to continuously monitor containers of nuclear material and the area in which they are stored. The system could be configured to provide off-site notification if any of the containers are moved or removed or if the area is accessed. Individual tags would be used to monitor storage containers, and additional tags could be used to record information regarding secondary storage units and room access. The capability to register small changes in tag position opens up the possibility of several other uses. These include continuously monitoring piping arrangements for design information verification or recording equipment positions for other safeguards systems, such as tracking the opening and closing of autoclaves as part of a cylinder tracking system or opening and closing valves on a sample or product take-off line. Combined with attribute tags, which transmit information from any kind of sensor by modulating the laser signal, LBIMS provides the capability to wirelessly and securely collect safeguards data, even in areas where radio-frequency or other wireless communication methods are not practicable. Four application types are described in this report: static item monitoring, in-process item monitoring with trigger tags, multi-layered integration with trigger tags, and line-of-sight data transfer with

  15. Non-Destructive, Laser-Based Individual Tree Aboveground Biomass Estimation in a Tropical Rainforest

    Directory of Open Access Journals (Sweden)

    Muhammad Zulkarnain Abd Rahman

    2017-03-01

    Full Text Available Recent methods for detailed and accurate biomass and carbon stock estimation of forests have been driven by advances in remote sensing technology. The conventional approach to biomass estimation heavily relies on the tree species and site-specific allometric equations, which are based on destructive methods. This paper introduces a non-destructive, laser-based approach (terrestrial laser scanner for individual tree aboveground biomass estimation in the Royal Belum forest reserve, Perak, Malaysia. The study area is in the state park, and it is believed to be one of the oldest rainforests in the world. The point clouds generated for 35 forest plots, using the terrestrial laser scanner, were geo-rectified and cleaned to produce separate point clouds for individual trees. The volumes of tree trunks were estimated based on a cylinder model fitted to the point clouds. The biomasses of tree trunks were calculated by multiplying the volume and the species wood density. The biomasses of branches and leaves were also estimated based on the estimated volume and density values. Branch and leaf volumes were estimated based on the fitted point clouds using an alpha-shape approach. The estimated individual biomass and the total above ground biomass were compared with the aboveground biomass (AGB value estimated using existing allometric equations and individual tree census data collected in the field. The results show that the combination of a simple single-tree stem reconstruction and wood density can be used to estimate stem biomass comparable to the results usually obtained through existing allometric equations. However, there are several issues associated with the data and method used for branch and leaf biomass estimations, which need further improvement.

  16. Implementation of the laser-based femtosecond precision synchronization system at FLASH

    International Nuclear Information System (INIS)

    Schulz, Sebastian

    2011-05-01

    FLASH, the high-gain free-electron laser (FEL) in Hamburg, enables the generation of light pulses with wavelengths in the soft X-ray region and durations down to a few femtoseconds. To fully exploit this capability in time-resolved pump-probe experiments, and for the projected externally seeded operation, the critical components of the accelerator and several external laser systems have to be synchronized with a temporal accuracy at least in the same order of magnitude. This can not be realized purely with established RF-based systems and therefore, an optical, laser-based synchronization system is required. In this thesis, the optical synchronization system of FLASH has been, based on previous successful proof-of-principle experiments, massively extended. One major topic is the comprehensive characterization of the timing reference of the system and a comparison of different types of such master laser oscillators, as well as studies on their short- and long-term stability. Similar investigations have been carried out for the upgraded and newly installed length-stabilized fiber links, which connect the remote locations at the accelerator to the optical timing reference. The successful demonstration of an all-optical synchronization of a Ti:sapphire oscillator with sub-10 femtosecond timing jitter and the connection of the photo injector laser system to the synchronization system mark further important key experiments of this thesis. The robustness of the actual implementations played a key role, as the synchronization system forms the basis for the future, operator-friendly arrival time feedback.

  17. Analysis of feature stability for laser-based determination of tissue thickness

    Science.gov (United States)

    Ernst, Floris; Schweikard, Achim; Stüber, Patrick; Bruder, Ralf; Wagner, Benjamin; Wissel, Tobias

    2015-03-01

    Localisation of the cranium is necessary for accurate stereotactic radiotherapy of malign lesions in the brain. This is achieved by immobilizing the patient's head (typically by using thermoplastic masks, bite blocks or combinations thereof) and x-ray imaging to determine the actual position of the patient with respect to the treatment device. In previous work we have developed a novel method for marker-less and non-invasive tracking of the skull using a combination of laser-based surface triangulation and the analysis of backscattered feature patterns of a tightly collimated NIR laser beam scanned over the patient's forehead. An HDR camera is coupled into the beam path of the laser scanning system to acquire one image per projected laser point. We have demonstrated that this setup is capable of accurately determining the tissue thickness for each triangulation point and consequently allows detecting the surface of the cranial bone with sub-millimetre accuracy. Typical clinical settings (treatment times of 15-90 min) require feature stability over time, since the determination of tissue thickness is achieved by machine learning methods trained on initial feature scans. We have collected initial scans of the forehead as well as long-term backscatter data (20 images per seconds over 30 min) from five subjects and extracted the relevant tissue features from the image streams. Based on the knowledge of the relationship between the tissue feature values and the tissue thickness, the analysis of the long-term data showed that the noise level is low enough to allow robust discrimination of tissue thicknesses of 0.5 mm.

  18. In-Process Detection of Weld Defects Using Laser-Based Ultrasound

    International Nuclear Information System (INIS)

    Bacher, G.D.; Kercel, S.W.; Kisner, R.A.; Klein, M.B.; Pouet, B.

    1999-01-01

    Laser-based ultrasonic (LBU) measurement shows great promise for on-line monitoring of weld quality in tailor-welded blanks. Tailor-welded blanks are steel blanks made from plates of differing thickness and/or properties butt-welded together; they are used in automobile manufacturing to produce body, frame, and closure panels. LBU uses a pulsed laser to generate the ultrasound and a continuous wave (CW) laser interferometer to detect the ultrasound at the point of interrogation to perform ultrasonic inspection. LBU enables in-process measurements since there is no sensor contact or near-contact with the workpiece. The authors are using laser-generated plate (Lamb) waves to propagate from one plate into the weld nugget as a means of detecting defects. This paper reports the results of the investigation of a number of inspection architectures based on processing of signals from selected plate waves, which are either reflected from or transmitted through the weld zone. Bayesian parameter estimation and wavelet analysis (both continuous and discrete) have shown that the LBU time-series signal is readily separable into components that provide distinguishing features which describe weld quality. The authors anticipate that, in an on-line industrial application, these measurements can be implemented just downstream from the weld cell. Then the weld quality data can be fed back to control critical weld parameters or alert the operator of a problem requiring maintenance. Internal weld defects and deviations from the desired surface profile can then be corrected before defective parts are produced

  19. All-polarization maintaining erbium fiber laser based on carbon nanowalls saturable absorber

    Science.gov (United States)

    Kurata, Shintaro; Izawa, Jun; Kawaguchi, Norihito

    2018-02-01

    We report a soliton mode locked femtosecond oscillation with all-polarization maintaining erbuim doped fiber laser based on Carbon Nanowalls saturable absorber (CNWs SA). To improve the stability and the capability of the oscillator, the all-polarization maintaining(all-PM) fiber is generally used since PM fiber is tolerant of stretches and bends. The saturable absorber is an optical device that placed in a laser cavity to suppress continuous wave operation to promote cooperation between many modes to sustain ultrashort pulse operation. We apply CNWs for the material of SAs in our oscillator. CNWs are one of the nanocarbon materials, which are a high-aspect-ratio structure in the cross-section, where, although their width and height range in a few micrometers, the thickness is as small as ten nanometers or so. A sheet of CNWs is made up of nano-size graphite grain aggregates. Then CNWs structure is expected to have a high absorption to the incident light and large modulation depth due to a small number of carbon layers as well as CNT and Graphene. With this all-PM fiber laser oscillator based on CNWs SA, the soliton mode-locked laser oscillated with 66.3MHz repetition frequency and its spectrum width is 5.6nm in FWHM. Average output power is 8.1mW with 122.5mW laser diode pump power. In addition, the laser amplification system with erbium-doped fiber is constructed and amplifies the femtosecond pulse laser into 268.2mW and 3000mW pumping power.

  20. Tunable, multiwavelength-swept fiber laser based on nematic liquid crystal device for fiber-optic electric-field sensor

    Science.gov (United States)

    Lee, Hyun Ji; Kim, Sung-Jo; Ko, Myeong Ock; Kim, Jong-Hyun; Jeon, Min Yong

    2018-03-01

    We propose a tunable multiwavelength-swept laser based on a nematic liquid crystal (NLC) Fabry-Perot (FP) etalon, which is embedded in the resonator of a wavelength-swept laser. We achieve the continuous wavelength tuning of the multiwavelength-swept laser by applying the electric field to the NLC FP etalon. The free spectral range of the fabricated NLC FP etalon is approximately 7.9 nm. When the electric field applied to the NLC FP etalon exceeds the threshold value (Fréedericksz threshold voltage), the output of the multiwavelength-swept laser can be tuned continuously. The tuning range of the multiwavelength-swept laser can be achieved at a value greater than 75 nm, which has a considerably wider tunable range than a conventional multiwavelength laser based on an NLC FP etalon. The slope efficiencies in the spectral and temporal domains for the tunable multiwavelength-swept laser are 22.2 nm/(mVrms / μm) and 0.17 ms/(mVrms / μm), respectively in the linear region. Therefore, the developed multiwavelength-swept laser based on the NLC FP etalon can be applied to an electric-field sensor. Because the wavelength measurement and time measurement have a linear relationship, the electric-field sensor can detect a rapid change in the electric-field intensity by measuring the peak change of the pulse in the temporal domain using the NLC FP etalon-based multiwavelength-swept laser.

  1. INDIRECT LABOR COSTS AND IMPLICATIONS FOR OVERHEAD ALLOCATION

    OpenAIRE

    Bea Chiang

    2013-01-01

    Cost accounting typically allocates indirect labor cost to cost object based on direct labor hours. The allocation process implicitly assumes that indirect labor costs vary proportionally with direct labor hours. The assumption of a linear relationship between indirect and direct labor is particularly suspicious at low production volume levels because there tends to be a fixed component in indirect labor. The linearity assumption is also challenged by recent increasing complexity of indirect ...

  2. Pharmacological modification of multi-drug resistance (MDR) in vitro detected by a novel fluorometric microculture cytotoxicity assay. Reversal of resistance and selective cytotoxic actions of cyclosporin A and verapamil on MDR leukemia T-cells.

    Science.gov (United States)

    Larsson, R; Nygren, P

    1990-07-15

    A novel fluorometric microculture cytotoxicity assay (FMCA), based on measurements of fluorescein diacetate (FDA) hydrolysis and DNA staining by Hoechst 33342, was used for drug sensitivity testing and detection of resistance reversal in acute lymphoblastic leukemia (ALL) cell lines. The 72-hr assay was found to be sensitive, reproducible and linearly related to the number of viable cells within a broad range of cell concentrations. At clinically achievable drug concentrations, the calcium channel blocker Verapamil (ver) and the immunosuppressant Cyclosporin A (csA) were found to partly reverse acquired Vincristine (vcr) resistance in multi-drug resistant (MDR) T-ALL L100 cells with little or no effect on the drug-sensitive parental L0 cell line. By combining the fluorometric indices, we found that low concentrations of csA were growth-inhibitory, whereas higher concentrations (greater than 10 micrograms/ml) were progressively cytotoxic for drug-sensitive L0 cells. In MDR L100 cells, on the other hand, csA produced significant cell kill even at low drug concentrations. Ver had no effects on sensitive L0 cells but showed considerable cytotoxic action towards MDR L100 cells. There was no apparent relationship between drug reversal of vcr resistance and the cytotoxic actions of the drug per se since the calcium channel blocker diltiazem (dil) significantly potentiated the actions of vcr on MDR L100 cells without being more toxic to these cells (compared to vcr-sensitive L0 cells).

  3. The Indirect cost of illness in Africa

    Directory of Open Access Journals (Sweden)

    Joses Muthuri Kirigia

    2018-06-01

    Full Text Available Background: The current study estimated (a the indirect costs associated with non-fatal disability and premature death across a wide range of diseases and health conditions in Africa in 2015 and (b the potential savings that could be accrued if countries were to meet the 3 health targets of the substainable development goal (SDG compared to the costs under the status quo. Methods: This study used the lost output or human capital approach to quantify the gross domestic product (GDP losses associated with the disability-adjusted-life-years (DALYs lost due to all causes by age group as well as by country economic classification (Group 1: 10 high/upper-middle income countries; Group 2: 17 lower-middle income countries; and Group 3: 27 low income countries. Results: The expected indirect cost of the 704,765,879 DALYs lost in Africa in 2015 was Int$ 2,983,187,560,197. Of this amount, 25.17%, 57.84% and 16.99% were incurred by the economies of the countries comprising Group 1, Group 2 and Group 3, respectively. Of the total continental indirect cost, 36.9%, 10.5%, 13.7%, 17.0%, 7.6%, 6.8% and 7.5% were associated with people aged 0-4, 5-14, 15-29, 30-49, 50-59, 60-69 and 70 years or older, respectively. Most of the total indirect cost (56.61% was attributable to maternal conditions, AIDS, tuberculosis (TB, malaria, neglected tropicald diseases (NTDs, non-communicable diseases and traffic injuries. Approximately half (47% of this cost could be avoided (or saved every year if the 3 (health targets of the SDG were fully met. Conclusion: The study estimated the total indirect cost of illness due to all causes by age group and country economic classification. The annual indirect cost is substantial. The findings contained in this paper suggest that health system strengthening should focus on both rich and poor countries, people of all ages and specific disease categories.

  4. Cruel intentions on television and in real life: can viewing indirect aggression increase viewers' subsequent indirect aggression?

    Science.gov (United States)

    Coyne, Sarah M; Archer, John; Eslea, Mike

    2004-07-01

    Numerous studies have shown that viewing violence in the media can influence an individual's subsequent aggression, but none have examined the effect of viewing indirect aggression. This study examines the immediate effect of viewing indirect and direct aggression on subsequent indirect aggression among 199 children ages 11 to 14 years. They were shown an indirect, direct, or no-aggression video and their subsequent indirect aggression was measured by negative evaluation of a confederate and responses to a vignette. Participants viewing indirect or direct aggression gave a more negative evaluation of and less money to a confederate than participants viewing no-aggression. Participants viewing indirect aggression gave less money to the confederate than those viewing direct aggression. Participants viewing indirect aggression gave more indirectly aggressive responses to an ambiguous situation and participants viewing direct aggression gave more directly aggressive responses. This study provides the first evidence that viewing indirect aggression in the media can have an immediate impact on subsequent aggression.

  5. Indirect genetic effects and kin recognition

    DEFF Research Database (Denmark)

    Alemu, Setegn Worku; Berg, Peer; Janss, Luc

    2014-01-01

    Social interactions among individuals are widespread, both in natural and domestic populations. As a result, trait values of individuals may be affected by genes in other individuals, a phenomenon known as indirect genetic effects (IGEs). IGEs can be estimated using linear mixed models. The tradi......Social interactions among individuals are widespread, both in natural and domestic populations. As a result, trait values of individuals may be affected by genes in other individuals, a phenomenon known as indirect genetic effects (IGEs). IGEs can be estimated using linear mixed models...... present a reduced model that yields estimates of the total heritable effects on kin, on non-kin and on all social partners of an individual, as well as the total heritable variance for response to selection. Finally we discuss the consequences of analysing data in which IGEs depend on relatedness using...

  6. Lack of indirect sensitization in vivo

    International Nuclear Information System (INIS)

    Hetzel, F.W.; Avery, K.; Mensinger, M.; Frinak, S.; Tidwell, C.

    1985-01-01

    The possible utility of respiratory inhibiting drugs as indirect radiation sensitizers has been investigated in both in vitro and in vivo systems. In vitro studies were conducted in V79 monolayer and spheroid cultures examining both respiratory inhibition and radiation survival as end points. These drugs (BCNU, Mustargen and Chlorambucil) were found to be potent respiratory inhibitors and, in the spheroid system, to be effective indirect radiation sensitizers with enhancement ratios of approximately 2.0. In vivo studies with these drugs have also been conducted in a C/sub 3/H mouse MCa tumor system to determine if the same reoxygenation effect observed in spheroids could be demonstrated in the solid tumor system. Detailed microelectrode studies, employing each drug at its LD/sub 10/ level, have been unable to demonstrate any drug induced reoxygenation for any of the drugs tested. Complete details are presented

  7. Direct or indirect - that is the question!

    DEFF Research Database (Denmark)

    Pallesen, Ulla

    2016-01-01

    Time has passed since the prevention of caries was performed by extending cavity preparations wide in the tooth and below the gingiva. In the same period adhesive techniques have improved and nowadays made it possible to extend the indications for direct composite resin restorations, also when...... rather destroyed teeth need to be restored. Although much can be solved by direct fillings and thereby make treatments less invasive for the tooth and less expensive for the patient, there still will be teeth, where the prognosis is improved, if an indirect restoration in terms of an inlay, onlay...... or crown is made. Factors as remaining tooth structure, endodontic treatment, number of teeth, caries risk, para-functional habits, material properties, economy etc. will all have an influence, when the dentist guides the patient to choose the best solution. What is best for the tooth – direct or indirect...

  8. Social intervention and risk reduction - indirect countermeasures

    International Nuclear Information System (INIS)

    Higgins, N.A.; Morrey, M.

    1996-01-01

    An indirect countermeasure (IC) is an action which is intended to mitigate detrimental effects experienced by individuals or the community after an accident. Indirect countermeasures (ICs) achieve this, both by averting radiation risks arising from the accident, but by removing or reducing other risks and sources of stress or harm to which the community may be subject. ICs naturally fall into two categories: social action ICs, which range from introducing compensation payments to providing information centres; and risk reducing ICs which mitigate risks to which the population might be exposed, such as radon. By including a consideration of ICs in an assessment of the optimal response, it is likely that a decision maker will become aware of a greater range of harms and benefits that might result from the application of a countermeasure. The decision maker will then be in a better position to judge the appropriateness of any action. (author)

  9. In vitro evaluation of new anticancer drugs, exemplified by vinorelbine, using the fluorometric microculture cytotoxicity assay on human tumor cell lines and patient biopsy cells.

    Science.gov (United States)

    Fridborg, H; Nygren, P; Dhar, S; Csoka, K; Kristensen, J; Larsson, R

    1996-09-01

    The feasibility of combined studies on a cell-line panel and primary cultures of patient tumor cells in the preclinical evaluation of new anticancer drugs was evaluated in a study of the activity and cross-resistance pattern in vitro of the new semi-synthetic vinca alkaloid vinorelbine (Vrb). The activity of Vrb was investigated in ten cell lines representing different resistance mechanisms and in a total of 256 fresh human tumor samples, using the fluorometric microculture cytotoxicity assay (FMCA). Resistance to Vrb in the cell lines was associated with expression of the multidrug resistance-mediating P-glycoprotein and the multidrug resistance-associated protein (MRP) and by a recently described tubulin-associated mechanism, while the cell lines with topoisomerase II- and glutathion-associated resistance did not show decreased sensitivity to the drug. Cross-resistance to vincristine (Vcr) and other tubulin-active agents was high in cell lines as well as in patient cells. As with most commonly used anti-cancer drugs, Vrb was more active in hematological than in solid tumor samples. Among the solid tumors investigated, the highest in vitro response rates were observed in ovarian cancer (27%), sarcoma (25%), non-small cell lung cancer (21%) and bladder cancer (20%), while no response was observed in renal or colorectal cancer. Compared to Vcr, Vrb appeared to be slightly more active in solid tumors and slightly less active in hematological tumors. The results show that although Vrb displays a high degree of cross-resistance to Vcr and other tubulin-active drugs, some difference in the activity spectrum could be detected and that the drug is sensitive to multiple mechanisms of resistance. The results also suggest that leukemias, ovarian cancer, sarcoma and bladder cancer are possible further targets for Vrb. The combination of studies on a cell-line panel and patient tumor cells from a broad spectrum of diagnoses to evaluate a new drug seems feasible and may give

  10. Studies on direct and indirect electrochemical immunoassays

    OpenAIRE

    Buckley, Eileen

    1989-01-01

    Two approaches to electrochemical immunoassay are reported. The first approach was an indirect method, involving an electroactive, enzyme-catalysed, substrate to product reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical detection of an immunoglo...

  11. Color indirect effects on melatonin regulation

    Science.gov (United States)

    Mian, Tian; Liu, Timon C.; Li, Yan

    2002-04-01

    Color indirect effect (CIE) is referred to as the physiological and psychological effects of color resulting from color vision. In previous papers, we have studied CIE from the viewpoints of the integrated western and Chinese traditional medicine, put forward the color-autonomic- nervous-subsystem model (CAM), and provided its time-theory foundation. In this paper, we applied it to study light effects on melatonin regulation in humans, and suggested that it is CIE that mediates light effects on melatonin suppression.

  12. Software Prefetching for Indirect Memory Accesses

    OpenAIRE

    Ainsworth, Sam; Jones, Timothy

    2017-01-01

    Many modern data processing and HPC workloads are heavily memory-latency bound. A tempting proposition to solve this is software prefetching, where special non-blocking loads are used to bring data into the cache hierarchy just before being required. However, these are difficult to insert to effectively improve performance, and techniques for automatic insertion are currently limited. This paper develops a novel compiler pass to automatically generate software prefetches for indirect mem...

  13. Draft of textbook focused on indirect taxes

    OpenAIRE

    Nováková, Hana

    2012-01-01

    The diploma thesis is about draft of textbook which is focused on indirect taxes for business school. The thesis is divided into theoretical and practical part. The theoretical part is focused on teaching tax issues at business school. Readers are introduced with basic studying documents, for example framework educational program and school educational program. In the following part I have conducted didactic analysis of curriculum and textbook of economics for business schools. The draft of t...

  14. Comment traduire en japonais les styles indirect et indirect libre de Madame Bovary ?

    Directory of Open Access Journals (Sweden)

    Hisaki Sawasaki

    2012-03-01

    Full Text Available Parmi les difficultés rencontrées lors de la traduction des textes littéraires occidentaux, en japonais, nous examinons le problème des styles indirect et indirect libre. Pour cela, en effectuant une petite mise au point grammaticale, nous comparons sept traductions de Madame Bovary de Gustave Flaubert, dont les dates de parution s’étendent sur une cinquantaine d’années. Cette période s’apparente, de notre point de vue, à un long itinéraire pour assimiler la notion occidentale des styles direct et indirect, tout en la conciliant avec les particularités du japonais. D’un autre côté, ce travail acharné des traducteurs a influencé quelque peu la langue japonaise. On trouve dans l’annexe tous les textes en japonais examinés.We will examine the difficulties met when translating Western literary texts in Japanese, in particular the problem of indirect and free indirect styles. We will define the grammatical issue and compare seven translations of Madame Bovary, published over a fifty year period. This time can be likened to a long path taken to digest the Western notion of direct and indirect styles, while reconciling it with Japanese language characteristics. On the other hand the translators’ relentless work has somewhat influenced the Japanese language. The annex will present all the Japanese texts examined.

  15. Indirect carotid cavernous fistula mimicking ocular myasthenia.

    Science.gov (United States)

    Leishangthem, Lakshmi; Satti, Sudhakar Reddy

    2017-10-19

    71-year-old woman with progressive left-sided, monocular diplopia and ptosis. Her symptoms mimicked ocular myasthenia, but she had an indirect carotid cavernous fistula (CCF). She was diagnosed with monocular myasthenia gravis (negative acetylcholinesterase antibody) after a positive ice test and started on Mestinon and underwent a thymectomy complicated by a brachial plexus injury. Months later, she developed left-sided proptosis and ocular bruit. She was urgently referred to neuro-interventional surgery and was diagnosed with an indirect high-flow left CCF, which was treated with Onyx liquid and platinum coil embolisation. Mestinon was discontinued. Her ophthalmic symptoms resolved. However, she was left with a residual left arm and hand hemiparesis and dysmetria secondary to a brachial plexus injury. Indirect CCF usually can present with subtle and progressive symptoms leading to delayed diagnosis or misdiagnosis. It is important for ophthalmologists to consider this differential in a patient with progressive ocular symptoms. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Indirect Comprehensive Review Board (ICRB). Final Report

    International Nuclear Information System (INIS)

    1996-12-01

    Lockheed Martin Idaho Technologies Company (LMITCO) used a systems engineering approach to take the first step toward defining a requirements baseline for all indirect work at the Idaho National Engineering Laboratory. The intent of this effort was to define the requirements for indirect work, identify the activities necessary to meet the requirements, and to produce defensible cost estimates for the work. The result of this effort is a scrubbed-down, defensible budget for all indirect work in FY 1997. Buying power for each dollar of direct work was increased by $.02. Recommendations are identified for improvements to this process in FY 1998. The purpose of this report is twofold. First is to report the final results of the 1996 ICRB process, and second is to document the process used such that incremental improvements may be made in future years. Objectives, processes, and approaches are described to provide a trail for future boards. Appendices contain copies of board composition, documentation of the process, as well as the actual training materials

  17. Interactive indirect illumination using adaptive multiresolution splatting.

    Science.gov (United States)

    Nichols, Greg; Wyman, Chris

    2010-01-01

    Global illumination provides a visual richness not achievable with the direct illumination models used by most interactive applications. To generate global effects, numerous approximations attempt to reduce global illumination costs to levels feasible in interactive contexts. One such approximation, reflective shadow maps, samples a shadow map to identify secondary light sources whose contributions are splatted into eye space. This splatting introduces significant overdraw that is usually reduced by artificially shrinking each splat's radius of influence. This paper introduces a new multiresolution approach for interactively splatting indirect illumination. Instead of reducing GPU fill rate by reducing splat size, we reduce fill rate by rendering splats into a multiresolution buffer. This takes advantage of the low-frequency nature of diffuse and glossy indirect lighting, allowing rendering of indirect contributions at low resolution where lighting changes slowly and at high-resolution near discontinuities. Because this multiresolution rendering occurs on a per-splat basis, we can significantly reduce fill rate without arbitrarily clipping splat contributions below a given threshold-those regions simply are rendered at a coarse resolution.

  18. [Laser-based quality assurance for robot-assisted milling at the base of the skull].

    Science.gov (United States)

    Maassen, M M; Malthan, D; Stallkamp, J; Schäfer, A; Dammann, F; Schwaderer, E; Zenner, H P

    2006-02-01

    reliable microsurgery on the cranial base. High-resolution laser-based geometric measurement of the operation site enables head registration without additional artificial landmarks. During the navigated operation, the procedure can be used to ensure that the resulting cavity matches the intended shape as determined in the preoperative planning phase. This will enable quantitative analysis of, and improvement in the quality of robot-assisted surgery in the future.

  19. Laser-based ultrasonics by dual-probe interferometer detection and narrow-band ultrasound generation

    Science.gov (United States)

    Huang, Jin

    1993-01-01

    Despite the advantages of laser-based ultrasonic (LBU) systems, the overall sensitivity of LBU systems needs to be improved for practical applications. Progress is reported to achieve better LBU detection accuracy and sensitivity for applications with surface waves and Lamb waves. A novel dual-probe laser interferometer has been developed to measure the same signal at two points. The dual-probe interferometer is a modification of a conventional single-probe interferometer in that the reference beam is guided to a second detecting point on the specimen surface to form a differential measurement mode, which measure the difference of the displacements at the two points. This dual-probe interferometer is particularly useful for accurate measurements of the speed and attenuation of surface waves and Lamb waves. The dual-probe interferometer has been applied to obtain accurate measurements of the surface wave speed and attenuation on surfaces of increasing surface roughness. It has also been demonstrated that with an appropriate signal processing method, namely, the power cepstrum method, the dual-probe interferometer is applicable to measure the local surface wave speed even when the probe separation is so small that the two waveforms in the interferometer output signal overlap in the time domain. Narrow-band signal generation and detection improve the sensitivity of LBU systems. It is proposed to use a diffraction grating to form an array of illuminating strips which form a source of narrowband surface and Lamb waves. The line-array of thermoelastic sources generates narrow-band signals whose frequency and bandwidth can be easily controlled. The optimum line-array parameters, such as width, spacing and the number of lines in the array have been derived theoretically and verified experimentally. Narrow-band signal generation with optimum parameters has been demonstrated. The enhanced LBU system with dual-probe detection and narrowband signal generation has been

  20. Application of laser-based profilometry to tubing in power generating utilities

    Science.gov (United States)

    Doyle, James L.

    1995-05-01

    Over the past several years lasers have been employed in an ever widening number of applications in an incredibly diverse set of markets. In the area of nondestructive testing, however, laser-based systems have only recently made inroads into the commercial markets. About ten years ago QUEST Integrated, Inc., began working with the U.S. Navy to adapt the principal of laser triangulation to solve a serious maintenance related problem. The internal surfaces of marine boiler tubes were experiencing pitting and corrosion which had resulted in catastrophic shipboard failures. At that time, conventional visual methods only allowed operators to inspect the first eighteen inches of the tube using a rigid borescope. If any pits were located, a mechanical stylus mechanism was used to obtain an approximate depth measurement of the pit. The condition of the balance of the tube was then extrapolated based on this extremely limited amount of information. Often the worst pitting was found in the bends of the tube, which could not be inspected by the visual method. Finally, a catastrophic boiler failure on an aircraft carrier resulted in the initiation of a search by the U.S. Navy for a better solution. Quest was contracted to develop an articulated probe which could negotiate the full length of a boiler tube with multiple bends, and generate a complete digital map of the inside surface. A key requirement of this probe would be rapid and quantitative measurement of internal features such as ID pits and corrosion. In 1987 QUEST delivered the first laser- optic tube inspection system to the U.S. Navy for use in marine boiler tubes. The Laser Optic Tube Inspection System (LOTISTM) was immediately put to use and paid for itself many times over in reduced maintenance costs. Over the next six years several generations of LOTIS were developed for the U.S. Navy, each one providing more capabilities, improved inspection speeds, and more user friendly operator interface. Today, LOTIS is

  1. Spatially indirect excitons in coupled quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chih-Wei Eddy [Univ. of California, Berkeley, CA (United States)

    2004-03-01

    Microscopic quantum phenomena such as interference or phase coherence between different quantum states are rarely manifest in macroscopic systems due to a lack of significant correlation between different states. An exciton system is one candidate for observation of possible quantum collective effects. In the dilute limit, excitons in semiconductors behave as bosons and are expected to undergo Bose-Einstein condensation (BEC) at a temperature several orders of magnitude higher than for atomic BEC because of their light mass. Furthermore, well-developed modern semiconductor technologies offer flexible manipulations of an exciton system. Realization of BEC in solid-state systems can thus provide new opportunities for macroscopic quantum coherence research. In semiconductor coupled quantum wells (CQW) under across-well static electric field, excitons exist as separately confined electron-hole pairs. These spatially indirect excitons exhibit a radiative recombination time much longer than their thermal relaxation time a unique feature in direct band gap semiconductor based structures. Their mutual repulsive dipole interaction further stabilizes the exciton system at low temperature and screens in-plane disorder more effectively. All these features make indirect excitons in CQW a promising system to search for quantum collective effects. Properties of indirect excitons in CQW have been analyzed and investigated extensively. The experimental results based on time-integrated or time-resolved spatially-resolved photoluminescence (PL) spectroscopy and imaging are reported in two categories. (i) Generic indirect exciton systems: general properties of indirect excitons such as the dependence of exciton energy and lifetime on electric fields and densities were examined. (ii) Quasi-two-dimensional confined exciton systems: highly statistically degenerate exciton systems containing more than tens of thousands of excitons within areas as small as (10 micrometer)2 were

  2. Indirect measurements of X-ray spectra

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    2006-01-01

    To the effects of measuring the spectral distribution of the radiation emitted by the x-ray tubes and electron accelerators, numerous procedures that are grouped in two big categories exist at the present time: direct and indirect methods. The first ones use high resolution detectors that should be positioned, together with the appropriate collimator, in the direction of the x ray beam. The user should be an expert in the use and correction of the obtained data by the different effects that affect the detector operation such as efficiency and resolution in terms of the energy of the detected radiation. The indirect procedures, although its are more simple to use, its also require a considerable space along the beam to position the ionization chamber and the necessary absorbents to construct by this way the denominated attenuation curve. We will analyze the operation principle of the indirect methods and a new proposal in which such important novelties are introduced as the beam dispersion to avoid to measure along the main beam and that of determination of the attenuation curve in simultaneous form. By this way, with a single shot of the tube, the attenuation curve is measured, being necessary at most a shot of additional calibration to know the relative response of the detectors used in the experimental array. The physical processes involved in the obtaining of an attenuation curve are very well well-known and this it finishes it can be theoretically calculated if the analytic form of the spectrum is supposed well-known. Finally, we will see a spectra reconstruction example with the Kramers parametric form and comparisons with numeric simulations carried out with broadly validated programs as well as the possibility of the use of solid state dosemeters in the obtention of the attenuation curve. (Author)

  3. Indirect quantum tomography of quadratic Hamiltonians

    Energy Technology Data Exchange (ETDEWEB)

    Burgarth, Daniel [Institute for Mathematical Sciences, Imperial College London, London SW7 2PG (United Kingdom); Maruyama, Koji; Nori, Franco, E-mail: daniel@burgarth.de, E-mail: kmaruyama@riken.jp [Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan)

    2011-01-15

    A number of many-body problems can be formulated using Hamiltonians that are quadratic in the creation and annihilation operators. Here, we show how such quadratic Hamiltonians can be efficiently estimated indirectly, employing very few resources. We found that almost all the properties of the Hamiltonian are determined by its surface and that these properties can be measured even if the system can only be initialized to a mixed state. Therefore, our method can be applied to various physical models, with important examples including coupled nano-mechanical oscillators, hopping fermions in optical lattices and transverse Ising chains.

  4. Indirect evidence of calcitonin secretion in man.

    Science.gov (United States)

    Caniggia, A; Gennari, C; Vattimo, A; Nardi, P; Nuti, R

    1976-09-01

    1. The effect of calcitonin, a large amount of calcium given orally, pentagastrin and glucagon on plasma 47Ca radioactivity curves in subjects pretreated with 47Ca was examined. 2. A sudden increase of plasma radioactivity after intravenous administration of calcitonin and pentagastrin and after the oral calcium load was observed in normal subjects; the intravenous infusion of glucagon was less effective. 3. Two thyroparathyroidectomized patients who responded to the calcitonin infusion did not respond to the oral calcium load. 4. These data may be considered to offer indirect evidence of endogenous calcitonin secretion in man.

  5. Quantum cascade laser-based analyzer for hydrogen sulfide detection at sub-parts-per-million levels

    Science.gov (United States)

    Nikodem, Michal; Krzempek, Karol; Stachowiak, Dorota; Wysocki, Gerard

    2018-01-01

    Due to its high toxicity, monitoring of hydrogen sulfide (H2S) concentration is essential in many industrial sites (such as natural gas extraction sites, petroleum refineries, geothermal power plants, or waste water treatment facilities), which require sub-parts-per-million sensitivities. We report on a quantum cascade laser-based spectroscopic system for detection of H2S in the midinfrared at ˜7.2 μm. We present a sensor design utilizing Herriott multipass cell and a wavelength modulation spectroscopy to achieve a detection limit of 140 parts per billion for 1-s integration time.

  6. The Dawn of Nuclear Photonics with Laser-based Gamma-rays

    International Nuclear Information System (INIS)

    Barty, C.J.

    2011-01-01

    A renaissance in nuclear physics is occurring around the world because of a new kind of incredibly bright, gamma-ray light source that can be created with short pulse lasers and energetic electron beams. These highly Mono-Energetic Gamma-ray (MEGa-ray) sources produce narrow, laser-like beams of incoherent, tunable gamma-rays and are enabling access and manipulation of the nucleus of the atom with photons or so called 'Nuclear Photonics'. Just as in the early days of the laser when photon manipulation of the valence electron structure of the atom became possible and enabling to new applications and science, nuclear photonics with laser-based gamma-ray sources promises both to open up wide areas of practical isotope-related, materials applications and to enable new discovery-class nuclear science. In the United States, the development of high brightness and high flux MEGa-ray sources is being actively pursued at the Lawrence Livermore National Laboratory in Livermore (LLNL), California near San Francisco. The LLNL work aims to create by 2013 a machine that will advance the state of the art with respect to source the peak brightness by 6 orders of magnitude. This machine will create beams of 1 to 2.3 MeV photons with color purity matching that of common lasers. In Europe a similar but higher photon energy gamma source has been included as part of the core capability that will be established at the Extreme Light Infrastructure Nuclear Physics (ELI-NP) facility in Magurele, Romania outside of Bucharest. This machine is expected to have an end point gamma energy in the range of 13 MeV. The machine will be co-located with two world-class, 10 Petawatt laser systems thus allowing combined intense-laser and gamma-ray interaction experiments. Such capability will be unique in the world. In this talk, Dr. Chris Barty from LLNL will review the state of the art with respect to MEGa-ray source design, construction and experiments and will describe both the ongoing projects

  7. Experimental and numerical studies on laser-based powder deposition of slurry erosion resistant materials

    Science.gov (United States)

    Balu, Prabu

    Slurry erosion (the removal of material caused by the randomly moving high velocity liquid-solid particle mixture) is a serious issue in crude oil drilling, mining, turbines, rocket nozzles, pumps, and boiler tubes that causes excessive downtime and high operating costs as a result of premature part failure. The goal of this research is to enhance the service life of high-value components subjected to slurry erosion by utilizing the concept of functionally graded metal-ceramic composite material (FGMCCM) in which the favorable properties of metal (toughness, ductility, etc.) and ceramic (hardness) are tailored smoothly to improve erosion resistance. Among the potential manufacturing processes, such as the laser-based powder deposition (LBPD), the plasma transferred arc (PTA), and the thermal spray the LBPD process offers good composition and microstructure control with a high deposition rate in producing the FGMCCM. This research focuses on the development of nickel-tungsten carbide (Ni-WC) based FGMCCM using the LBPD process for applications the above mentioned. The LBPD of Ni-WC involves the introduction of Ni and WC powder particle by an inert gas into the laser-formed molten pool at the substrate via nozzles. The LBPD of Ni-WC includes complex multi-physical interactions between the laser beam, Ni-WC powder, substrate, and carrier and shielding gases that are governed by a number of process variables such as laser power, scanning speed, and powder flow rate. In order to develop the best Ni-WC based slurry erosion resistant material using the LBPD process, the following challenges associated with the fabrication and the performance evaluation need to be addressed: 1) flow behavior of the Ni-WC powder and its interaction with the laser, 2) the effect of the process variables, the material compositions, and the thermo-physical properties on thermal cycles, temperature gradient, cooling rate, and residual stress formation within the material and the subsequent

  8. Third European Company Survey – Direct and indirect employee participation

    NARCIS (Netherlands)

    Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo

    2015-01-01

    This report studies practices in EU establishments for direct and indirect employee participation in decision-making. Indirect employee participation is the involvement of employee representatives in decision-making processes, while direct employee participation describes direct interaction between

  9. Indirect Estimation of Selected Measures of Fertility and Marital ...

    African Journals Online (AJOL)

    DLHS6

    2018-01-09

    Jan 9, 2018 ... marital status distribution data of India especially of the 2011 census in deriving indirectly the fertility measures .... 2011 Census, Economic and Political weekly, EPW Vol. ... Indirect Estimates of Total Fertility Rate Using Child.

  10. THE INDIRECT OBJECT (IO) – ALBANIAN AND ENGLISH

    OpenAIRE

    Shkelqim Millaku; Xhevahire Topanica

    2016-01-01

    The aim of this study is too corporate the function of the indirect object between Albanian and English language. The function and the Albanian typical case for indirect object are dative and ablative. This grammatical phenomena is the full contrast between two languages because in English language doesn’t exist dative and ablative us in Albanian. In Albanian and English language, the indirect object is more heterogenic than the direct object. The indirect (direct) object in both of languages...

  11. On the Relative Size of Direct and Indirect Taxation

    OpenAIRE

    Soldatos, Gerasimos T.

    2014-01-01

    Modifying the standard analytical apparatuses for direct and indirect tax evasion to incorporate forward indirect tax shift in a monopolistically competitive environment, this paper maintains that indirect tax evasion would exceed for sure direct tax evasion only under consumer risk neutrality and a tax policy zeroing the tax shift. Also, in the presence of tax evasion, there cannot be optimal direct-indirect tax mix, because tax evasion is accompanied by uncertainty and hence, nonlinearities...

  12. Microdosimetric concepts for indirect radiation reactions

    International Nuclear Information System (INIS)

    Pohlit, W.

    1976-01-01

    It is the aim of microdosimetric models to get information about the influence of microscopic energy deposition by radiation on radiation reactions. Two parameters are always of interest: the energy necessary to produce a certain reaction and the volume in which this energy has to be desposited. In the simple case of an aqueous solution with point targets a complete description of radiation reactions in targets with various concentrations can be given. This model takes into consideration the distinct energy deposition on the particle track, diffusion of radicals and a mean energy necessary for a certain reaction at the target. Typical dose effect curves are obtained which allow the determination of all these quantities from experiments. The model has been tested with the oxydation of iron atoms in aqueous solutions and has been applied for more complex targets such as different alcohols and amino acids. The oxygen consumption in these reactions is used as an easy method for continuous measurement of these indirect reactions. It is the aim of such experiments to get enough quantitative microscopic data on indirect radiation reactions that these reactions can also be followed in living cells

  13. The indirect strategies of internationalization of companies

    Directory of Open Access Journals (Sweden)

    Đorđević Momčilo

    2012-01-01

    Full Text Available The subject of this work are, as mentioned in the title, the indirect strategies of internationalization of companies. The first part talks about the new business environment, the factors that lead to changes and their implications. It is at the same time the business context, which must be taken into consideration that determines the success of companies in the new business environment. In this paper, the emphasis is on company business in international markets, and the selection of appropriate strategies of internationalization, which will be responsible for this new business environment. There are many reasons that are discussed in this paper, and would rather indicate that partners from different countries to accept different strategies, rather than opting for a strategy of export, or a strategy of direct investments abroad. The dynamic technical and technological development, and its universal impact, among other relevant factors, put in the first place the importance of different strategies which is achieved through technology transfer, knowledge and experience whereby the exports, as a classic strategy of involvement in international trade, becomes significantly more difficult. Also, the internationalization of enterprises through direct investment abroad, involves many difficulties related to fitting in a foreign enterprise environment, and a high risk strategy. In addition, there is still a large number of countries do not allow wholly owned foreign enterprises. The paper discusses the value of various indirect internationalization strategy, which may be useful for those domestic companies that are in front of problem the choice of acceptable strategies of internationalization.

  14. Indirect costs of teaching in Canadian hospitals.

    Science.gov (United States)

    MacKenzie, T A; Willan, A R; Cox, M A; Green, A

    1991-01-01

    We sought to determine whether there are indirect costs of teaching in Canadian hospitals. To examine cost differences between teaching and nonteaching hospitals we estimated two cost functions: cost per case and cost per patient-day (dependent variables). The independent variables were number of beds, occupancy rate, teaching ratio (number of residents and interns per 100 beds), province, urbanicity (the population density of the county in which the hospital was situated) and wage index. Within each hospital we categorized a random sample of patient discharges according to case mix and severity of illness using age and standard diagnosis and procedure codes. Teaching ratio and case severity were each highly correlated positively with the dependent variables. The other variables that led to higher costs in teaching hospitals were wage rates and number of beds. Our regression model could serve as the basis of a reimbursement system, adjusted for severity and teaching status, particularly in provinces moving toward introducing case-weighting mechanisms into their payment model. Even if teaching hospitals were paid more than nonteaching hospitals because of the difference in the severity of illness there should be an additional allowance to cover the indirect costs of teaching. PMID:1898870

  15. Cooperation under indirect reciprocity and imitative trust.

    Science.gov (United States)

    Saavedra, Serguei; Smith, David; Reed-Tsochas, Felix

    2010-10-27

    Indirect reciprocity, a key concept in behavioral experiments and evolutionary game theory, provides a mechanism that allows reciprocal altruism to emerge in a population of self-regarding individuals even when repeated interactions between pairs of actors are unlikely. Recent empirical evidence show that humans typically follow complex assessment strategies involving both reciprocity and social imitation when making cooperative decisions. However, currently, we have no systematic understanding of how imitation, a mechanism that may also generate negative effects via a process of cumulative advantage, affects cooperation when repeated interactions are unlikely or information about a recipient's reputation is unavailable. Here we extend existing evolutionary models, which use an image score for reputation to track how individuals cooperate by contributing resources, by introducing a new imitative-trust score, which tracks whether actors have been the recipients of cooperation in the past. We show that imitative trust can co-exist with indirect reciprocity mechanisms up to a threshold and then cooperation reverses -revealing the elusive nature of cooperation. Moreover, we find that when information about a recipient's reputation is limited, trusting the action of third parties towards her (i.e. imitating) does favor a higher collective cooperation compared to random-trusting and share-alike mechanisms. We believe these results shed new light on the factors favoring social imitation as an adaptive mechanism in populations of cooperating social actors.

  16. Cooperation under indirect reciprocity and imitative trust.

    Directory of Open Access Journals (Sweden)

    Serguei Saavedra

    Full Text Available Indirect reciprocity, a key concept in behavioral experiments and evolutionary game theory, provides a mechanism that allows reciprocal altruism to emerge in a population of self-regarding individuals even when repeated interactions between pairs of actors are unlikely. Recent empirical evidence show that humans typically follow complex assessment strategies involving both reciprocity and social imitation when making cooperative decisions. However, currently, we have no systematic understanding of how imitation, a mechanism that may also generate negative effects via a process of cumulative advantage, affects cooperation when repeated interactions are unlikely or information about a recipient's reputation is unavailable. Here we extend existing evolutionary models, which use an image score for reputation to track how individuals cooperate by contributing resources, by introducing a new imitative-trust score, which tracks whether actors have been the recipients of cooperation in the past. We show that imitative trust can co-exist with indirect reciprocity mechanisms up to a threshold and then cooperation reverses -revealing the elusive nature of cooperation. Moreover, we find that when information about a recipient's reputation is limited, trusting the action of third parties towards her (i.e. imitating does favor a higher collective cooperation compared to random-trusting and share-alike mechanisms. We believe these results shed new light on the factors favoring social imitation as an adaptive mechanism in populations of cooperating social actors.

  17. 21 CFR 870.3640 - Indirect pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...

  18. System markets: Indirect network effects in action, or inaction?

    NARCIS (Netherlands)

    J.L.G. Binken (Jeroen)

    2010-01-01

    textabstractIn this dissertation, I empirically examine system markets up close. More specifically I examine indirect network effects, both demand-side and supply-side indirect network effects. Indirect network effects are the source of positive feedback in system markets, or so network effect

  19. Non-radiometric immunoassays fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) and radioimmunoassay (RIA) for evaluation of thyroid function in normal and hypothyroid dogs

    Energy Technology Data Exchange (ETDEWEB)

    Jerico, M.M.; Larsson, C.E. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Medica]. E-mail: marciajerico@hotmail.com; Mendonca, B.B. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina . Lab. de Hormonios e Genetica Molecular; Otsuka, M. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Hospital Veterinario; Maganin Junior, A. [Canil da Policia Militar do Estado de Sao Paulo, SP (Brazil)

    2001-07-01

    We proposed the comparison of thyroxine (T4) and free thyroxine (FT4) measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in thyroid function evaluation of normal (n=50) and hypothyroid dogs (n=9). T4 and FT4 serum concentrations were measured in basal conditions and 6 h after TRH stimulation (200 mug/IV). All our reference values are based on the 5th and 95th percentile. The reference values for basal T4 in healthy dogs were 0.50 to 2.35 mug/dL (FIA), 0.50 to 2.51 mug/dL (FEIA) and 0.35 to 0.74 mug/dL (RIA). After TRH, the values were >= 1.37 mug/dL (FIA), >= 0,26 mug/dL (FEIA) and >= 0.40 mug/dL (RIA). Basal FT4 values in healthy dogs were 0.65 to 2.20 ng/dL (FIA), 0.38 to 1.43 ng/dL (FEIA) and 0.10 to 1.24 ng/dL (RIA). After TRH, the values were >= 1.30 ng/dL (FIA), >= 0.77 ng/dL (FEIA) and >=0.50 ng/dL (RIA). In hypothyroid dogs, the mean +- SD for T4 in basal conditions and after TRH were 0.24 +- 0.20 mug/dL and 0.26 +- 0.20 mug/dL (FIA), 0.27 +- 0.12 mug/dL and 0.32 +- 0.51 mug/dL (FEIA) and 0.19 +- 0.30 mug/dL and 0,24 +- 0.09 mug/dL (RIA), respectively. In the same group the mean +- SD basal FT4 values and after TRH were 0.28 +- 0.33 ng/dL and 0.28 +- 0.39 ng/dL (FIA), 0,12 +- 0.26 ng/dL and 0.23 +- 0.56 ng/dL (FEIA) and 0,15 +- 0,15 ng/dL and 0,17 +- 0,28 ng/dL (RIA), respectively. Significant differences (p<0.05) between the normal and hypothyroid groups (Kruskall-Wallis test) were observed in the three methods and between basal and stimulated values in normal dogs (Wilcoxon test), by the three methods. The best sensitivity for diagnosing hypothyroidism was obtained through T4 values (100%), and the best specificity through FT4 values (100%), both determined by FIA after TRH stimulation. We conclude that T4 and FT4 measured by fluoroimmunoassay after TRH stimulation can be an excellent alternative. (author)

  20. Non-radiometric immunoassays (fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) and radioimmunoassay (RIA) for evaluation of thyroid function in normal and hypothyroid dogs

    International Nuclear Information System (INIS)

    Jerico, M.M.; Larsson, C.E.

    2001-01-01

    We proposed the comparison of thyroxine (T4) and free thyroxine (FT4) measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in thyroid function evaluation of normal (n=50) and hypothyroid dogs (n=9). T4 and FT4 serum concentrations were measured in basal conditions and 6 h after TRH stimulation (200 mug/IV). All our reference values are based on the 5th and 95th percentile. The reference values for basal T4 in healthy dogs were 0.50 to 2.35 mug/dL (FIA), 0.50 to 2.51 mug/dL (FEIA) and 0.35 to 0.74 mug/dL (RIA). After TRH, the values were >= 1.37 mug/dL (FIA), >= 0,26 mug/dL (FEIA) and >= 0.40 mug/dL (RIA). Basal FT4 values in healthy dogs were 0.65 to 2.20 ng/dL (FIA), 0.38 to 1.43 ng/dL (FEIA) and 0.10 to 1.24 ng/dL (RIA). After TRH, the values were >= 1.30 ng/dL (FIA), >= 0.77 ng/dL (FEIA) and >=0.50 ng/dL (RIA). In hypothyroid dogs, the mean +- SD for T4 in basal conditions and after TRH were 0.24 +- 0.20 mug/dL and 0.26 +- 0.20 mug/dL (FIA), 0.27 +- 0.12 mug/dL and 0.32 +- 0.51 mug/dL (FEIA) and 0.19 +- 0.30 mug/dL and 0,24 +- 0.09 mug/dL (RIA), respectively. In the same group the mean +- SD basal FT4 values and after TRH were 0.28 +- 0.33 ng/dL and 0.28 +- 0.39 ng/dL (FIA), 0,12 +- 0.26 ng/dL and 0.23 +- 0.56 ng/dL (FEIA) and 0,15 +- 0,15 ng/dL and 0,17 +- 0,28 ng/dL (RIA), respectively. Significant differences (p<0.05) between the normal and hypothyroid groups (Kruskall-Wallis test) were observed in the three methods and between basal and stimulated values in normal dogs (Wilcoxon test), by the three methods. The best sensitivity for diagnosing hypothyroidism was obtained through T4 values (100%), and the best specificity through FT4 values (100%), both determined by FIA after TRH stimulation. We conclude that T4 and FT4 measured by fluoroimmunoassay after TRH stimulation can be an excellent alternative. (author)

  1. Characterization of electrically-active defects in ultraviolet light-emitting diodes with laser-based failure analysis techniques

    International Nuclear Information System (INIS)

    Miller, Mary A.; Tangyunyong, Paiboon; Cole, Edward I.

    2016-01-01

    Laser-based failure analysis techniques demonstrate the ability to quickly and non-intrusively screen deep ultraviolet light-emitting diodes (LEDs) for electrically-active defects. In particular, two laser-based techniques, light-induced voltage alteration and thermally-induced voltage alteration, generate applied voltage maps (AVMs) that provide information on electrically-active defect behavior including turn-on bias, density, and spatial location. Here, multiple commercial LEDs were examined and found to have dark defect signals in the AVM indicating a site of reduced resistance or leakage through the diode. The existence of the dark defect signals in the AVM correlates strongly with an increased forward-bias leakage current. This increased leakage is not present in devices without AVM signals. Transmission electron microscopy analysis of a dark defect signal site revealed a dislocation cluster through the pn junction. The cluster included an open core dislocation. Even though LEDs with few dark AVM defect signals did not correlate strongly with power loss, direct association between increased open core dislocation densities and reduced LED device performance has been presented elsewhere [M. W. Moseley et al., J. Appl. Phys. 117, 095301 (2015)

  2. Characterization of electrically-active defects in ultraviolet light-emitting diodes with laser-based failure analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Mary A.; Tangyunyong, Paiboon; Cole, Edward I. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1086 (United States)

    2016-01-14

    Laser-based failure analysis techniques demonstrate the ability to quickly and non-intrusively screen deep ultraviolet light-emitting diodes (LEDs) for electrically-active defects. In particular, two laser-based techniques, light-induced voltage alteration and thermally-induced voltage alteration, generate applied voltage maps (AVMs) that provide information on electrically-active defect behavior including turn-on bias, density, and spatial location. Here, multiple commercial LEDs were examined and found to have dark defect signals in the AVM indicating a site of reduced resistance or leakage through the diode. The existence of the dark defect signals in the AVM correlates strongly with an increased forward-bias leakage current. This increased leakage is not present in devices without AVM signals. Transmission electron microscopy analysis of a dark defect signal site revealed a dislocation cluster through the pn junction. The cluster included an open core dislocation. Even though LEDs with few dark AVM defect signals did not correlate strongly with power loss, direct association between increased open core dislocation densities and reduced LED device performance has been presented elsewhere [M. W. Moseley et al., J. Appl. Phys. 117, 095301 (2015)].

  3. Laser-based flow cytometric analysis of genotoxicity of humans exposed to ionizing radiation during the Chernobyl accident

    International Nuclear Information System (INIS)

    Jensen, R.H.; Bigbee, W.L.; Langlois, R.G.; Grant, S.G.; Pleshanov, P.G.; Chirkov, A.A.; Pilinskaya, M.A.

    1990-01-01

    An analytical technique has been developed that allows laser-based flow cytometric measurement of the frequency of red blood cells that have lost allele-specific expression of a cell surface antigen due to genetic toxicity in bone marrow precursor cells. Previous studies demonstrated a correlation of such effects with the exposure of each individual to mutagenic phenomena, such as ionizing radiation, and the effects can persist for the lifetime of each individual. During the emergency response to the nuclear power plant accident at Chernobyl, Ukraine, USSR, a number of people were exposed to whole body doses of ionizing radiation. Some of these individuals were tested with this laser-based assay and found to express a dose-dependent increase in the frequency of variant red blood cells that appears to be a persistent biological effect. All data indicate that this assay might well be used as a biodosimeter to estimate radiation dose and also as an element to be used for estimating the risk of each individual to develop cancer due to radiation exposure. 17 refs., 5 figs

  4. Quantum Cascade Laser-Based Infrared Microscopy for Label-Free and Automated Cancer Classification in Tissue Sections.

    Science.gov (United States)

    Kuepper, Claus; Kallenbach-Thieltges, Angela; Juette, Hendrik; Tannapfel, Andrea; Großerueschkamp, Frederik; Gerwert, Klaus

    2018-05-16

    A feasibility study using a quantum cascade laser-based infrared microscope for the rapid and label-free classification of colorectal cancer tissues is presented. Infrared imaging is a reliable, robust, automated, and operator-independent tissue classification method that has been used for differential classification of tissue thin sections identifying tumorous regions. However, long acquisition time by the so far used FT-IR-based microscopes hampered the clinical translation of this technique. Here, the used quantum cascade laser-based microscope provides now infrared images for precise tissue classification within few minutes. We analyzed 110 patients with UICC-Stage II and III colorectal cancer, showing 96% sensitivity and 100% specificity of this label-free method as compared to histopathology, the gold standard in routine clinical diagnostics. The main hurdle for the clinical translation of IR-Imaging is overcome now by the short acquisition time for high quality diagnostic images, which is in the same time range as frozen sections by pathologists.

  5. Indirect Climatic Effects of Major Volcanic Eruptions

    Science.gov (United States)

    Hofmann, D. J.

    2007-05-01

    The direct effects on climate, related to atmospheric emissions to the atmosphere following major volcanic eruptions, are well-known although the sparseness of such eruptions make detailed study on the range of such variations difficult. In general terms, infrared absorption by volcanic emissions to the stratosphere result in local heating early in the event when gaseous sulfur compounds exist. This early period is followed by gas to particle conversion, on a time scale of 1-2 months, promoting the formation of sulfuric acid-water droplets. Coagulation and droplet growth result in the "volcanic stratospheric aerosol layer" which is related to the predominant direct climatic effect of large eruptions, the cooling of the troposphere by backscattering of solar visible radiation to space with a recovery time scale of 1-2 years. In this paper we will discuss some of the less-known "indirect" effects of the volcanic stratospheric aerosol on climate. We label them indirect as they act on climate through intermediary atmospheric constituents. The intermediaries in the volcanic indirect climatic effect are generally atmospheric greenhouse gases or other atmospheric gases and conditions which affect greenhouse gases. For example, cooling of the troposphere following major eruptions reduces the growth rate of atmospheric carbon dioxide related to respiration by the terrestrial biosphere. In addition, redirection of part of the direct solar beam into diffuse radiation by the volcanic stratospheric aerosol stimulates plant photosynthesis, further reducing the carbon dioxide growth rate. The growth rate of the second-most important atmospheric greenhouse gas, methane, is also affected by volcanic emissions. Volcanic stratospheric aerosol particles provide surface area which catalyzes heterogeneous chemical reactions thus stimulating removal of stratospheric ozone, also a greenhouse gas. Although major droughts usually related to ENSO events have opposite effects on carbon

  6. Indirect effects in community ecology: Their definition, study and importance.

    Science.gov (United States)

    Strauss, S Y

    1991-07-01

    The diversity of indirect interactions that can occur within communities is large. Recent research on indirect interactions is scattered in the literature under numerous labels. The definition of indirect effects is an important aspect of their study, and clarifies some of the subtle differences among indirect effects found in natural communities. Choosing which species to study, how to manipulate species and for what duration, which attributes to measure and, finally, which analytical techniques to use are all problems facing the community ecologist. Ultimately, we are striving for the best means of determining the relative importance of direct and indirect effects in structuring communities. Copyright © 1991. Published by Elsevier Ltd.

  7. Indirect evaporative coolers with enhanced heat transfer

    Science.gov (United States)

    Kozubal, Eric; Woods, Jason; Judkoff, Ron

    2015-09-22

    A separator plate assembly for use in an indirect evaporative cooler (IEC) with an air-to-air heat exchanger. The assembly includes a separator plate with a first surface defining a dry channel and a second surface defining a wet channel. The assembly includes heat transfer enhancements provided on the first surface for increasing heat transfer rates. The heat transfer enhancements may include slit fins with bodies extending outward from the first surface of separator plate or may take other forms including vortex generators, offset strip fins, and wavy fins. In slit fin implementations, the separator plate has holes proximate to each of the slit fins, and the separator plate assembly may include a sealing layer applied to the second surface of the separator plate to block air flow through the holes. The sealing layer can be a thickness of adhesive, and a layer of wicking material is applied to the adhesive.

  8. Haloperidol Selectively Remodels Striatal Indirect Pathway Circuits

    Science.gov (United States)

    Sebel, Luke E; Graves, Steven M; Chan, C Savio; Surmeier, D James

    2017-01-01

    Typical antipsychotic drugs are widely thought to alleviate the positive symptoms of schizophrenia by antagonizing dopamine D2 receptors expressed by striatal spiny projection neurons (SPNs). What is less clear is why antipsychotics have a therapeutic latency of weeks. Using a combination of physiological and anatomical approaches in ex vivo brain slices from transgenic mice, it was found that 2 weeks of haloperidol treatment induced both intrinsic and synaptic adaptations specifically within indirect pathway SPNs (iSPNs). Perphenazine treatment had similar effects. Some of these adaptations were homeostatic, including a drop in intrinsic excitability and pruning of excitatory corticostriatal glutamatergic synapses. However, haloperidol treatment also led to strengthening of a subset of excitatory corticostriatal synapses. This slow remodeling of corticostriatal iSPN circuitry is likely to play a role in mediating the delayed therapeutic action of neuroleptics. PMID:27577602

  9. Indirect Encoding in Neuroevolutionary Ship Handling

    Directory of Open Access Journals (Sweden)

    Miroslaw Lacki

    2018-03-01

    Full Text Available In this paper the author compares the efficiency of two encoding schemes for artificial intelligence methods used in the neuroevolutionary ship maneuvering system. This may be also be seen as the ship handling system that simulates a learning process of a group of artificial helmsmen - autonomous control units, created with an artificial neural network. The helmsman observes input signals derived form an enfironment and calculates the values of required parameters of the vessel maneuvering in confined waters. In neuroevolution such units are treated as individuals in population of artificial neural networks, which through environmental sensing and evolutionary algorithms learn to perform given task efficiently. The main task of this project is to evolve a population of helmsmen with indirect encoding and compare results of simulation with direct encoding method.

  10. Indirect adaptive control of discrete chaotic systems

    International Nuclear Information System (INIS)

    Salarieh, Hassan; Shahrokhi, Mohammad

    2007-01-01

    In this paper an indirect adaptive control algorithm is proposed to stabilize the fixed points of discrete chaotic systems. It is assumed that the functionality of the chaotic dynamics is known but the system parameters are unknown. This assumption is usually applicable to many chaotic systems, such as the Henon map, logistic and many other nonlinear maps. Using the recursive-least squares technique, the system parameters are identified and based on the feedback linearization method an adaptive controller is designed for stabilizing the fixed points, or unstable periodic orbits of the chaotic maps. The stability of the proposed scheme has been shown and the effectiveness of the control algorithm has been demonstrated through computer simulations

  11. Indirect Tire Monitoring System - Machine Learning Approach

    Science.gov (United States)

    Svensson, O.; Thelin, S.; Byttner, S.; Fan, Y.

    2017-10-01

    The heavy vehicle industry has today no requirement to provide a tire pressure monitoring system by law. This has created issues surrounding unknown tire pressure and thread depth during active service. There is also no standardization for these kind of systems which means that different manufacturers and third party solutions work after their own principles and it can be hard to know what works for a given vehicle type. The objective is to create an indirect tire monitoring system that can generalize a method that detect both incorrect tire pressure and thread depth for different type of vehicles within a fleet without the need for additional physical sensors or vehicle specific parameters. The existing sensors that are connected communicate through CAN and are interpreted by the Drivec Bridge hardware that exist in the fleet. By using supervised machine learning a classifier was created for each axle where the main focus was the front axle which had the most issues. The classifier will classify the vehicles tires condition and will be implemented in Drivecs cloud service where it will receive its data. The resulting classifier is a random forest implemented in Python. The result from the front axle with a data set consisting of 9767 samples of buses with correct tire condition and 1909 samples of buses with incorrect tire condition it has an accuracy of 90.54% (0.96%). The data sets are created from 34 unique measurements from buses between January and May 2017. This classifier has been exported and is used inside a Node.js module created for Drivecs cloud service which is the result of the whole implementation. The developed solution is called Indirect Tire Monitoring System (ITMS) and is seen as a process. This process will predict bad classes in the cloud which will lead to warnings. The warnings are defined as incidents. They contain only the information needed and the bandwidth of the incidents are also controlled so incidents are created within an

  12. Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Anastasi, A., E-mail: antonioanastasi89@gmail.com [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Dipartimento MIFT, Università di Messina, Messina (Italy); Basti, A.; Bedeschi, F.; Bartolini, M. [INFN, Sezione di Pisa (Italy); Cantatore, G. [INFN, Sezione di Trieste e G.C. di Udine (Italy); Università di Trieste, Trieste (Italy); Cauz, D. [INFN, Sezione di Trieste e G.C. di Udine (Italy); Università di Udine, Udine (Italy); Corradi, G. [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Dabagov, S. [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Lebedev Physical Institute and NRNU MEPhI, Moscow (Russian Federation); Di Sciascio, G. [INFN, Sezione di Roma Tor Vergata, Roma (Italy); Di Stefano, R. [INFN, Sezione di Napoli (Italy); Università di Cassino, Cassino (Italy); Driutti, A. [INFN, Sezione di Trieste e G.C. di Udine (Italy); Università di Udine, Udine (Italy); Escalante, O. [Università di Napoli, Napoli (Italy); Ferrari, C. [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Istituto Nazionale di Ottica del C.N.R., UOS Pisa, via Moruzzi 1, 56124, Pisa (Italy); Fienberg, A.T. [University of Washington, Box 351560, Seattle, WA 98195 (United States); Fioretti, A.; Gabbanini, C. [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Istituto Nazionale di Ottica del C.N.R., UOS Pisa, via Moruzzi 1, 56124, Pisa (Italy); Gioiosa, A. [INFN, Sezione di Lecce (Italy); Università del Molise, Pesche (Italy); Hampai, D. [Laboratori Nazionali Frascati dell' INFN, Via E. Fermi 40, 00044 Frascati (Italy); Hertzog, D.W. [University of Washington, Box 351560, Seattle, WA 98195 (United States); and others

    2017-01-11

    We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

  13. Sub-picosecond timing fluctuation suppression in laser-based atmospheric transfer of microwave signal using electronic phase compensation

    Science.gov (United States)

    Chen, Shijun; Sun, Fuyu; Bai, Qingsong; Chen, Dawei; Chen, Qiang; Hou, Dong

    2017-10-01

    We demonstrated a timing fluctuation suppression in outdoor laser-based atmospheric radio-frequency transfer over a 110 m one-way free-space link using an electronic phase compensation technique. Timing fluctuations and Allan Deviation are both measured to characterize the instability of transferred frequency incurred during the transfer process. With transferring a 1 GHz microwave signal over a timing fluctuation suppressed transmission link, the total root-mean-square (rms) timing fluctuation was measured to be 920 femtoseconds in 5000 s, with fractional frequency instability on the order of 1 × 10-12 at 1 s, and order of 2 × 10-16 at 1000 s. This atmospheric frequency transfer scheme with the timing fluctuation suppression technique can be used to fast build an atomic clock-based frequency free-space transmission link since its stability is superior to a commercial Cs and Rb clock.

  14. Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Anastasi, A.; Basti, A.; Bedeschi, F.; Bartolini, M.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Di Sciascio, G.; Di Stefano, R.; Driutti, A.; Escalante, O.; Ferrari, C.; Fienberg, A. T.; Fioretti, A.; Gabbanini, C.; Gioiosa, A.; Hampai, D.; Hertzog, D. W.; Iacovacci, M.; Karuza, M.; Kaspar, J.; Liedl, A.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Pauletta, G.; Piacentino, G. M.; Raha, N.; Rossi, E.; Santi, L.; Venanzoni, G.

    2017-01-01

    We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

  15. A laser-based sizing/velocimetry technique to investigate the secondary atomization of aluminum gel propellants

    Science.gov (United States)

    Mueller, D. C.; Turns, S. R.

    1994-01-01

    A laser-based, forward-scatter diagnostic technique, employing a single laser sheet, has been developed to simultaneously measure the size and velocity of individual 10-150 micron droplets in a dilute polydisperse droplet stream (less than 1000 particles/cc) and to detect the presence of burning aluminum in these same droplets. Spectral emission from aluminum vapor in the 390-400 nm wavelength region is used as an indication of burning aluminum. The technique utilizes a 4-mm uniformly illuminated probe volume, eliminating trajectory-dependent particle sizing and size-dependent system detection bias. Particle sizing is based on a correlation of particle size with near-forward scattered light intensity. Calculations show average particle sizing variation to be within 3.5% over the expected range of refractive indices. Calibrations using a range of optical pinholes (10-100 micron) were used to verify the above sizing correlation.

  16. A widely tunable, near-infrared laser-based trace gas sensor for hydrogen cyanide (HCN) detection in exhaled breath

    Science.gov (United States)

    Azhar, M.; Mandon, J.; Neerincx, A. H.; Liu, Z.; Mink, J.; Merkus, P. J. F. M.; Cristescu, S. M.; Harren, F. J. M.

    2017-11-01

    A compact, cost-effective sensor is developed for detection of hydrogen cyanide (HCN) in exhaled breath within seconds. For this, an off-axis integrated cavity output spectroscopy setup is combined with a widely tunable compact near-infrared laser (tunability 1527-1564 nm). For HCN a detection sensitivity has been obtained of 8 ppbv in nitrogen (within 1 s), equal to a noise equivalent absorption sensitivity of 1.9 × 10-9 cm-1 Hz-1/2. With this sensor we demonstrated the presence of HCN in exhaled breath; its detection could be a good indicator for bacterial lung infection. Due to its compact, cost-effective and user-friendly design, this laser-based sensor has the potential to be implemented in future clinical applications.

  17. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10 MeV

    Directory of Open Access Journals (Sweden)

    S. Busold

    2014-03-01

    Full Text Available We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 10^{9} particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E_{0} at FWHM. A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf field is applied via a rf cavity for energy compression at a synchronous phase of -90  deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  18. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10Â MeV

    Science.gov (United States)

    Busold, S.; Schumacher, D.; Deppert, O.; Brabetz, C.; Kroll, F.; Blažević, A.; Bagnoud, V.; Roth, M.

    2014-03-01

    We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 109 particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E0 at FWHM). A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf) field is applied via a rf cavity for energy compression at a synchronous phase of -90 deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  19. Multiwavelength Raman-fiber-laser-based long-distance remote sensor for simultaneous measurement of strain and temperature.

    Science.gov (United States)

    Han, Young-Geun; Tran, T V A; Kim, Sang-Hyuck; Lee, Sang Bae

    2005-06-01

    We propose a simple and flexible multiwavelength Raman-fiber-laser-based long-distance remote-sensing scheme for simultaneous measurement of strain and temperature by use of fiber Bragg gratings. By combining two uniform fiber Bragg gratings with a tunable chirped fiber grating, we readily achieve simultaneous two-channel sensing probes with a high extinction ratio of more than approximately 50 dB over a 50-km distance. When strain and temperature are applied, lasing wavelength separation and shift occur, respectively, since the two uniform fiber Bragg gratings have identical material composition and different cladding diameters. This allows simultaneous measurement of strain and temperature for long-distance sensing applications of more than 50 km.

  20. Feasibility Study on 3-D Printing of Metallic Structural Materials with Robotized Laser-Based Metal Additive Manufacturing

    Science.gov (United States)

    Ding, Yaoyu; Kovacevic, Radovan

    2016-07-01

    Metallic structural materials continue to open new avenues in achieving exotic mechanical properties that are naturally unavailable. They hold great potential in developing novel products in diverse industries such as the automotive, aerospace, biomedical, oil and gas, and defense. Currently, the use of metallic structural materials in industry is still limited because of difficulties in their manufacturing. This article studied the feasibility of printing metallic structural materials with robotized laser-based metal additive manufacturing (RLMAM). In this study, two metallic structural materials characterized by an enlarged positive Poisson's ratio and a negative Poisson's ratio were designed and simulated, respectively. An RLMAM system developed at the Research Center for Advanced Manufacturing of Southern Methodist University was used to print them. The results of the tensile tests indicated that the printed samples successfully achieved the corresponding mechanical properties.

  1. Laser-based linear and nonlinear guided elastic waves at surfaces (2D) and wedges (1D).

    Science.gov (United States)

    Hess, Peter; Lomonosov, Alexey M; Mayer, Andreas P

    2014-01-01

    The characteristic features and applications of linear and nonlinear guided elastic waves propagating along surfaces (2D) and wedges (1D) are discussed. Laser-based excitation, detection, or contact-free analysis of these guided waves with pump-probe methods are reviewed. Determination of material parameters by broadband surface acoustic waves (SAWs) and other applications in nondestructive evaluation (NDE) are considered. The realization of nonlinear SAWs in the form of solitary waves and as shock waves, used for the determination of the fracture strength, is described. The unique properties of dispersion-free wedge waves (WWs) propagating along homogeneous wedges and of dispersive wedge waves observed in the presence of wedge modifications such as tip truncation or coatings are outlined. Theoretical and experimental results on nonlinear wedge waves in isotropic and anisotropic solids are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Study of gain-coupled distributed feedback laser based on high order surface gain-coupled gratings

    Science.gov (United States)

    Gao, Feng; Qin, Li; Chen, Yongyi; Jia, Peng; Chen, Chao; Cheng, LiWen; Chen, Hong; Liang, Lei; Zeng, Yugang; Zhang, Xing; Wu, Hao; Ning, Yongqiang; Wang, Lijun

    2018-03-01

    Single-longitudinal-mode, gain-coupled distributed feedback (DFB) lasers based on high order surface gain-coupled gratings are achieved. Periodic surface metal p-contacts with insulated grooves realize gain-coupled mechanism. To enhance gain contrast in the quantum wells without the introduction of effective index-coupled effect, groove length and depth were well designed. Our devices provided a single longitudinal mode with the maximum CW output power up to 48.8 mW/facet at 971.31 nm at 250 mA without facet coating, 3dB linewidth (39 dB). Optical bistable characteristic was observed with a threshold current difference. Experimentally, devices with different cavity lengths were contrasted on power-current and spectrum characteristics. Due to easy fabrication technique and stable performance, it provides a method of fabricating practical gain-coupled distributed feedback lasers for commercial applications.

  3. A laser-based technology for fabricating a soda-lime glass based microfluidic device for circulating tumour cell capture.

    Science.gov (United States)

    Nieto, Daniel; Couceiro, Ramiro; Aymerich, Maria; Lopez-Lopez, Rafael; Abal, Miguel; Flores-Arias, María Teresa

    2015-10-01

    We developed a laser-based technique for fabricating microfluidic microchips on soda-lime glass substrates. The proposed methodology combines a laser direct writing, as a manufacturing tool for the fabrication of the microfluidics structures, followed by a post-thermal treatment with a CO2 laser. This treatment will allow reshaping and improving the morphological (roughness) and optical qualities (transparency) of the generated microfluidics structures. The use of lasers commonly implemented for material processing makes this technique highly competitive when compared with other glass microstructuring approaches. The manufactured chips were tested with tumour cells (Hec 1A) after being functionalized with an epithelial cell adhesion molecule (EpCAM) antibody coating. Cells were successfully arrested on the pillars after being flown through the device giving our technology a translational application in the field of cancer research. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Direct and indirect detection of supersymmetric dark matter; Detection directe et indirecte de matiere sombre supersymetrique

    Energy Technology Data Exchange (ETDEWEB)

    Mayet, F

    2001-09-01

    A substantial body of astrophysical evidence supports the existence of non-baryonic dark matter in the universe. One of the leading dark matter candidates is the neutralino predicted by the supersymmetric extensions of the standard model of particle physics. Different detectors have been designed for the detection, either indirect or direct, of the neutralino. Related to indirect detection, the present work has been performed in the context of the AMS experiment. A precursor version of the spectrometer was flown on the space shuttle Discovery in June 1998. The detector included an Aerogel Threshold Cherenkov counter (ATC) to identify antiprotons, whose spectrum may be used to infer a neutralino signal. The analysis of the ATC data is presented including an evaluation of the flight performance and a description of the optimization of the antiproton selection. An antiproton analysis is also reported. A phenomenological study allows us to investigate the discovery potential of this indirect method. This thesis also includes the development of a new detector (MACHe3) designed for direct neutralino search using a superfluid {sup 3}He bolometer operated at ultra low temperatures. The data analysis of the prototype cell is presented. A Monte Carlo simulation has been developed, in order to optimize the detector design for direct neutralino search. These results are compared with theoretical predictions of supersymmetric models, thus highlighting the discovery potential of this detector and its complementarity with existing devices. (author)

  5. Laser-based measurements of 18O/16O stable isotope ratios (δ18O in wine samples

    Directory of Open Access Journals (Sweden)

    Gupta M

    2013-09-01

    Full Text Available Manish Gupta,1 J Brian Leen,1 Elena Simone Franklin Berman,1 Aldo Ciambotti2 1Los Gatos Research, Mountain View, CA, USA; 2Consiglio per la Ricerca e la Sperimentazione in Agricoltura, Centro di Ricerca per l'Enologia, Asti, Italy Abstract: Wine counterfeiting is an international, multi-billion dollar issue, with some estimates suggesting that up to 5% of wines sold at auctions or secondary markets are fraudulent. Isotope ratio mass spectrometer (IRMS measurements of the 18O/16O stable isotope ratio (δ18O of water-in-wine have been used for wine authentication; however, these analyses are time-consuming and costly. In this preliminary study, off-axis integrated cavity output spectroscopy (OA-ICOS is used to quantify δ18O in wines. This laser-based method has been extensively used to study water isotopes for hydrological and medical applications. Recently, the development of a spectral contaminant identifier (SCI has extended the application of these OA-ICOS analyzers to contaminated water samples (eg, plant, soil, and leaf waters. Here, we utilize OA-ICOS with the SCI to characterize wine samples (9%–15% ethanol, and show that the laser-based instrument provides a δ18O measurement precision of ±0.07‰ (1σ and agrees with IRMS to within ±0.63‰ (1σ. Moreover, by training the SCI on isotopically-characterized wines, the agreement with IRMS improves to within ±0.30‰ (1σ. The utility of the instrument is demonstrated by measuring watered and mixed wines. The method presented here can be readily extended to address other food authentication applications. Keywords: wine isotopes, wine fraud, counterfeit wines, OA-ICOS

  6. Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fife, Julie L., E-mail: julie.fife@psi.ch [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Rappaz, Michel [Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Pistone, Mattia [Institute for Geochemistry and Petrology, Swiss Federal Institute of Technology of Zurich, Zurich (Switzerland); Celcer, Tine [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); The Centre of Excellence for Biosensors, Instrumentation and Process Control, Solkan (Slovenia); Mikuljan, Gordan [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Stampanoni, Marco [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology and University of Zurich, Zurich (Switzerland)

    2012-05-01

    A laser-based heating system has been developed at the TOMCAT beamline of the Swiss Light Source for in situ observations of moderate-to-high-temperature applications of materials. Understanding the formation of materials at elevated temperatures is critical for determining their final properties. Synchrotron-based X-ray tomographic microscopy is an ideal technique for studying such processes because high spatial and temporal resolutions are easily achieved and the technique is non-destructive, meaning additional analyses can take place after data collection. To exploit the state-of-the-art capabilities at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the Swiss Light Source, a general-use moderate-to-high-temperature furnace has been developed. Powered by two diode lasers, it provides controlled localized heating, from 673 to 1973 K, to examine many materials systems and their dynamics in real time. The system can also be operated in various thermal modalities. For example, near-isothermal conditions at a given sample location can be achieved with a prescribed time-dependent temperature. This mode is typically used to study isothermal phase transformations; for example, the formation of equiaxed grains in metallic systems or to nucleate and grow bubble foams in silicate melts under conditions that simulate volcanic processes. In another mode, the power of the laser can be fixed and the specimen moved at a constant speed in a user-defined thermal gradient. This is similar to Bridgman solidification, where the thermal gradient and cooling rate control the microstructure formation. This paper details the experimental set-up and provides multiple proofs-of-concept that illustrate the versatility of using this laser-based heating system to explore, in situ, many elevated-temperature phenomena in a variety of materials.

  7. Performance comparison of direct and indirect lighting systems

    International Nuclear Information System (INIS)

    Rubinstein, F.; Morse, O.; Clark, T.

    1993-01-01

    The performance of a retrofitted indirect lighting system was compared to the performance of a typical de-lamped direct lighting system in a partitioned office space. Power, illuminance and luminance measurements were made for the de-lamped direct lighting system and after installation of the indirect lighting system with various lamp and ballast combinations. Using the same lamps and ballasts, average workplace illuminance was slightly higher with indirect lighting than with direct lighting. With indirect lighting, workplace lumen efficacy was 4.5% lower due to the higher power draw of the lamps in the more open and cooler indirect fixtures. Indirect lighting with 36 watt T-8 lamps and electronic ballasts achieved an initial average workplace illuminance of 45 foot-candles in the partitioned office space at only 1.1 w/ft 2

  8. Direct and indirect punishment among strangers in the field.

    Science.gov (United States)

    Balafoutas, Loukas; Nikiforakis, Nikos; Rockenbach, Bettina

    2014-11-11

    Many interactions in modern human societies are among strangers. Explaining cooperation in such interactions is challenging. The two most prominent explanations critically depend on individuals' willingness to punish defectors: In models of direct punishment, individuals punish antisocial behavior at a personal cost, whereas in models of indirect reciprocity, they punish indirectly by withholding rewards. We investigate these competing explanations in a field experiment with real-life interactions among strangers. We find clear evidence of both direct and indirect punishment. Direct punishment is not rewarded by strangers and, in line with models of indirect reciprocity, is crowded out by indirect punishment opportunities. The existence of direct and indirect punishment in daily life indicates the importance of both means for understanding the evolution of cooperation.

  9. Indirect land use change and biofuel policy

    International Nuclear Information System (INIS)

    Kocoloski, Matthew; Griffin, W Michael; Matthews, H Scott

    2009-01-01

    Biofuel debates often focus heavily on carbon emissions, with parties arguing for (or against) biofuels solely on the basis of whether the greenhouse gas emissions of biofuels are less than (or greater than) those of gasoline. Recent studies argue that land use change leads to significant greenhouse gas emissions, making some biofuels more carbon intensive than gasoline. We argue that evaluating the suitability and utility of biofuels or any alternative energy source within the limited framework of plus and minus carbon emissions is too narrow an approach. Biofuels have numerous impacts, and policy makers should seek compromises rather than relying solely on carbon emissions to determine policy. Here, we estimate that cellulosic ethanol, despite having potentially higher life cycle CO 2 emissions (including from land use) than gasoline, would still be cost-effective at a CO 2 price of $80 per ton or less, well above estimated CO 2 mitigation costs for many alternatives. As an example of the broader approach to biofuel policy, we suggest the possibility of using the potential cost reductions of cellulosic ethanol relative to gasoline to balance out additional carbon emissions resulting from indirect land use change as an example of ways in which policies could be used to arrive at workable solutions.

  10. Spherical cows in dark matter indirect detection

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, Nicolás [Centro de Investigaciones, Universidad Antonio Nariño, Cra 3 Este # 47A-15, Bogotá (Colombia); Necib, Lina; Slatyer, Tracy R., E-mail: nicolas.bernal@uan.edu.co, E-mail: lnecib@mit.edu, E-mail: tslatyer@mit.edu [Center for Theoretical Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2016-12-01

    Dark matter (DM) halos have long been known to be triaxial, but in studies of possible annihilation and decay signals they are often treated as approximately spherical. In this work, we examine the asymmetry of potential indirect detection signals of DM annihilation and decay, exploiting the large statistics of the hydrodynamic simulation Illustris. We carefully investigate the effects of the baryons on the sphericity of annihilation and decay signals for both the case where the observer is at 8.5 kpc from the center of the halo (exemplified in the case of Milky Way-like halos), and for an observer situated well outside the halo. In the case of Galactic signals, we find that both annihilation and decay signals are expected to be quite symmetric, with axis ratios very different from 1 occurring rarely. In the case of extragalactic signals, while decay signals are still preferentially spherical, the axis ratio for annihilation signals has a much flatter distribution, with elongated profiles appearing frequently. Many of these elongated profiles are due to large subhalos and/or recent mergers. Comparing to gamma-ray emission from the Milky Way and X-ray maps of clusters, we find that the gamma-ray background appears less spherical/more elongated than the expected DM signal from the large majority of halos, and the Galactic gamma ray excess appears very spherical, while the X-ray data would be difficult to distinguish from a DM signal by elongation/sphericity measurements alone.

  11. Indirectly cooled large thin superconducting CDF solenoid

    International Nuclear Information System (INIS)

    Kondo, Kunitaka; Mori, Shigeki; Yoshizaki, Ryozo; Saito, Ryusei; Asano, Katsuhiko.

    1985-01-01

    The manufacturing technique of the indirectly cooled large thin superconducting solenoid for the collider detector facility (CDF solenoid) has been studied through cooperation of University of Tsukuba and the National Laboratory for High Energy Physics of the Ministry of Education of Japan, and the Fermi National Accelerator Laboratory in the U.S. Fabrication and testing of the solenoid has recently been completed by Hitachi. The CDF solenoid has a large-sized thin structure for meeting the requirement by experiments to be applied. Hitachi has thus developed a variety of new technologies including the design standard, coil cooling method, material selection, and manufacturing technique in accordance with experimental data, which were confirmed in a series of analyses and tests made on various prototypes. The CDF solenoid, built using Hitachi's new technologies, is of the world's top class among equipment of this type. This paper outlines the design criteria for the major components employed in the CDF solenoid and the test results of the solenoid. (author)

  12. An Automatic Indirect Immunofluorescence Cell Segmentation System

    Directory of Open Access Journals (Sweden)

    Yung-Kuan Chan

    2014-01-01

    Full Text Available Indirect immunofluorescence (IIF with HEp-2 cells has been used for the detection of antinuclear autoantibodies (ANA in systemic autoimmune diseases. The ANA testing allows us to scan a broad range of autoantibody entities and to describe them by distinct fluorescence patterns. Automatic inspection for fluorescence patterns in an IIF image can assist physicians, without relevant experience, in making correct diagnosis. How to segment the cells from an IIF image is essential in developing an automatic inspection system for ANA testing. This paper focuses on the cell detection and segmentation; an efficient method is proposed for automatically detecting the cells with fluorescence pattern in an IIF image. Cell culture is a process in which cells grow under control. Cell counting technology plays an important role in measuring the cell density in a culture tank. Moreover, assessing medium suitability, determining population doubling times, and monitoring cell growth in cultures all require a means of quantifying cell population. The proposed method also can be used to count the cells from an image taken under a fluorescence microscope.

  13. INDIRECT WRITTEN CORRECTIVE FEEDBACK, REVISION, AND LEARNING

    Directory of Open Access Journals (Sweden)

    Fatemeh Poorebrahim

    2017-01-01

    Full Text Available Corrective feedback, the necessity of providing it, and how it should be provided has been one of the hot topics in the area of ELT. Amid continuing controversies over whether providing feedback helps L2 learners improve their writing accuracy, many research studies have been undertaken to compare the relative effectiveness of different types of feedback. However, the difference between two types of indirect corrective feedback, namely indication and indication plus location, have not been properly examined yet. Motivated to narrow this gap, this study is designed to compare two groups of Iranian learners, each revising their papers based on one of the aforementioned options. For data analysis, a series of independent samples t tests were employed. The results revealed that the difference between the two groups in their reduction of errors from the original draft to the revision of each task followed a growing trend and became significant. Nonetheless, the difference in accuracy of new pieces of writing fell short of significance. Finally, it was found that error reduction in revision stage cannot be considered as learning. The results of the study, discussed in relation to that of others, implicate that the purpose for which feedback is provided is essential in determining the type of feedback; more explicit feedback is better for revising purposes while more implicit feedback is good for learning purposes.

  14. Indirect Sensitivities to the Scale of Supersymmetry

    CERN Document Server

    Ellis, Jonathan Richard; Olive, Keith A; Weiglein, Georg

    2005-01-01

    Precision measurements, now and at a future linear electron-positron collider (ILC), can provide indirect information about the possible scale of supersymmetry. We illustrate the present-day and possible future ILC sensitivities within the constrained minimal supersymmetric extension of the Standard Model (CMSSM), in which there are three independent soft supersymmetry-breaking parameters m_{1/2}, m_0 and A_0. We analyze the present and future sensitivities separately for M_W, sin^2(theta_eff), (g-2)_mu, BR(b -> s gamma), BR(B_s -> mu+ mu-), M_h and Higgs branching ratios. We display the observables as functions of m_{1/2}, fixing m_0 so as to obtain the cold dark matter density allowed by WMAP and other cosmological data for specific values of A_0, tan beta and mu > 0. In a second step, we investigate the combined sensitivity of the currently available precision observables, M_W, sin^2(theta_eff), (g-2)_mu and BR(b -> s gamma), by performing a chi^2 analysis. The current data are in very good agreement with ...

  15. Theoretical research on color indirect effects

    Science.gov (United States)

    Liu, T. C.; Liao, Changjun; Liu, Songhao

    1995-05-01

    Color indirect effects (CIE) means the physiological and psychological effects of color resulting from color vision. In this paper, we study CIE from the viewpoints of the integrated western and Chinese traditional medicine and the time quantum theory established by C. Y. Liu et al., respectively, and then put forward the color-automatic-nervous-subsystem model that could color excites parasympathetic subsystem and hot color excites sympathetic subsystem. Our theory is in agreement with modern color vision theory, and moreover, it leads to the resolution of the conflict between the color code theory and the time code theory oncolor vision. For the latitude phenomena on athlete stars number and the average lifespan, we also discuss the possibility of UV vision. The applications of our theory lead to our succeeding in explaining a number of physiological and psychological effects of color, in explaining the effects of age on color vision, and in explaining the Chinese chromophototherapy. We also discuss its application to neuroimmunology. This research provides the foundation of the clinical applications of chromophototherapy.

  16. Decentralized indirect methods for learning automata games.

    Science.gov (United States)

    Tilak, Omkar; Martin, Ryan; Mukhopadhyay, Snehasis

    2011-10-01

    We discuss the application of indirect learning methods in zero-sum and identical payoff learning automata games. We propose a novel decentralized version of the well-known pursuit learning algorithm. Such a decentralized algorithm has significant computational advantages over its centralized counterpart. The theoretical study of such a decentralized algorithm requires the analysis to be carried out in a nonstationary environment. We use a novel bootstrapping argument to prove the convergence of the algorithm. To our knowledge, this is the first time that such analysis has been carried out for zero-sum and identical payoff games. Extensive simulation studies are reported, which demonstrate the proposed algorithm's fast and accurate convergence in a variety of game scenarios. We also introduce the framework of partial communication in the context of identical payoff games of learning automata. In such games, the automata may not communicate with each other or may communicate selectively. This comprehensive framework has the capability to model both centralized and decentralized games discussed in this paper.

  17. Indirect land use change and biofuel policy

    Science.gov (United States)

    Kocoloski, Matthew; Griffin, W. Michael; Matthews, H. Scott

    2009-09-01

    Biofuel debates often focus heavily on carbon emissions, with parties arguing for (or against) biofuels solely on the basis of whether the greenhouse gas emissions of biofuels are less than (or greater than) those of gasoline. Recent studies argue that land use change leads to significant greenhouse gas emissions, making some biofuels more carbon intensive than gasoline. We argue that evaluating the suitability and utility of biofuels or any alternative energy source within the limited framework of plus and minus carbon emissions is too narrow an approach. Biofuels have numerous impacts, and policy makers should seek compromises rather than relying solely on carbon emissions to determine policy. Here, we estimate that cellulosic ethanol, despite having potentially higher life cycle CO2 emissions (including from land use) than gasoline, would still be cost-effective at a CO2 price of 80 per ton or less, well above estimated CO2 mitigation costs for many alternatives. As an example of the broader approach to biofuel policy, we suggest the possibility of using the potential cost reductions of cellulosic ethanol relative to gasoline to balance out additional carbon emissions resulting from indirect land use change as an example of ways in which policies could be used to arrive at workable solutions.

  18. Noninvasive wearable sensor for indirect glucometry.

    Science.gov (United States)

    Zilberstein, Gleb; Zilberstein, Roman; Maor, Uriel; Righetti, Pier Giorgio

    2018-04-02

    A noninvasive mini-sensor for blood glucose concentration assessment has been developed. The monitoring is performed by gently pressing a wrist or fingertip onto the chemochromic mixture coating a thin glass or polymer film positioned on the back panel of a smart watch with PPG/HRM (photoplethysmographic/heart rate monitoring sensor). The various chemochromic components measure the absolute values of the following metabolites present in the sweat: acetone, acetone beta-hydroxybutirate, aceto acetate, water, carbon dioxide, lactate anion, pyruvic acid, Na and K salts. Taken together, all these parameters give information about blood glucose concentration, calculated via multivariate analysis based on neural network algorithms built into the sensor. The Clarke Error Grid shows an excellent correlation between data measured by the standard invasive glucose analyser and the present noninvasive sensor, with all points aligned along a 45-degree diagonal and contained almost exclusively in sector A. Graphs measuring glucose levels five times a day (prior, during and after breakfast and prior, during and after lunch), for different individuals (males and females) show a good correlation between the two curves of conventional, invasive meters vs. the noninvasive sensor, with an error of ±15%. This novel, noninvasive sensor for indirect glucometry is fully miniaturized, easy to use and operate and could represent a valid alternative in clinical settings and for individual, personal users, to current, invasive tools. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Bioelectrochemical Systems for Indirect Biohydrogen Production

    KAUST Repository

    Regan, John M.

    2014-01-01

    Bioelectrochemical systems involve the use of exoelectrogenic (i.e., anode-reducing) microbes to produce current in conjunction with the oxidation of reduced compounds. This current can be used directly for power in a microbial fuel cell, but there are alternate uses of this current. One such alternative is the production of hydrogen in a microbial electrolysis cell (MEC), which accomplishes cathodic proton reduction with a slight applied potential by exploiting the low redox potential produced by exoelectrogens at the anode. As an indirect approach to biohydrogen production, these systems are not subject to the hydrogen yield constraints of fermentative processes and have been proven to work with virtually any biodegradable organic substrate. With continued advancements in reactor design to reduce the system internal resistance, increase the specific surface area for anode biofilm development, and decrease the material costs, MECs may emerge as a viable alternative technology for biohydrogen production. Moreover, these systems can also incorporate other value-added functionalities for applications in waste treatment, desalination, and bioremediation.

  20. System markets: Indirect network effects in action, or inaction?

    OpenAIRE

    Binken, Jeroen

    2010-01-01

    textabstractIn this dissertation, I empirically examine system markets up close. More specifically I examine indirect network effects, both demand-side and supply-side indirect network effects. Indirect network effects are the source of positive feedback in system markets, or so network effect theory tells us. Systems are composed of complementary and interdependent products, such as hardware and software. For instance, a video game system is composed of the video game console, on the one han...

  1. Indirect detection methods: Looking for what is not there

    International Nuclear Information System (INIS)

    Yeung, E.S.

    1989-01-01

    Indirect detection allows one to monitor species that normally do not give a response. It has grown from an intellectual curiosity to become an extremely useful tool. For volume displacement, polarimetry gives the best results. For charge displacement, ion chromatography and capillary zone electrophoresis are ideal situations for applying indirect fluorescence detection. LOD surpasses all but the most specialized detection schemes. Future developments in systems specially designed for indirect detection should make these schemes even more powerful

  2. Indirect Catastrophic Injuries in Olympic Styles of Wrestling in Iran

    OpenAIRE

    Kordi, Ramin; Ziaee, Vahid; Rostami, Mohsen; Wallace, W. Angus

    2011-01-01

    Background: Data on indirect catastrophic injuries in wrestling are scarce. Objectives: To develop a profile of indirect catastrophic injuries in international styles of wrestling and to describe possible risk factors. Study Design: Retrospective case series; Level of evidence, 3. Methods: Indirect catastrophic injuries that occurred in wrestling clubs in Iran from July 1998 to June 2005 were identified by contacting several sources. The cases were retrospectively reviewed. Results: The injur...

  3. Tipping and Concentration in Markets with Indirect Network Effects

    OpenAIRE

    Jean-Pierre H. Dubé; Günter J. Hitsch; Pradeep K. Chintagunta

    2010-01-01

    This paper develops a framework for measuring “tipping”—the increase in a firm's market share dominance caused by indirect network effects. Our measure compares the expected concentration in a market to the hypothetical expected concentration that would arise in the absence of indirect network effects. In practice, this measure requires a model that can predict the counterfactual market concentration under different parameter values capturing the strength of indirect network effects. We build...

  4. Indirect estimation of radioactivity in containerized cargo

    International Nuclear Information System (INIS)

    Jarman, K.D.; Scherrer, C.; Smith, L.E.; Chilton, L.K.; Anderson, K.K.; Ressler, J.J.; Trease, L.L.

    2011-01-01

    Naturally occurring radioactive material in containerized cargo challenges the state of the art in national and international efforts to detect illicit nuclear and radiological material in transported containers. Current systems are being evaluated and new systems envisioned to provide the high probability of detection necessary to thwart potential threats, combined with extremely low nuisance and false alarm rates necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that inspection must be rapid, requiring relatively non-intrusive, indirect measurements of cargo from outside containers to the extent possible. With increasing information content in such measurements, it is natural to ask how the information might be combined to improve detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma-ray spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma-ray counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We test our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics, while relying on several simplifying assumptions and approximations, holds the potential to support improvement of

  5. Development of in-situ laser based cutting technique for shock absorber rear nut in pressurized heavy water reactors. CP-2.1

    International Nuclear Information System (INIS)

    Vishwakarma, S.C.; Jain, R.K.; Upadhyaya, B.N.; Choubey, Ambar; Agrawal, D.K.; Oak, S.M.

    2007-01-01

    We have developed a laser based cutting technique for shock absorber rear nuts in pressurized heavy water reactors (PHWRs). This technique has been successfully used for in-situ laser cutting at RAPS-3 reactor. The technique consists of a motorized compact fixture, which holds a fiber optic beam delivery cutting nozzle and can be operated remotely

  6. 42 CFR 412.322 - Indirect medical education adjustment factor.

    Science.gov (United States)

    2010-10-01

    ... Payment System for Inpatient Hospital Capital Costs Basic Methodology for Determining the Federal Rate for Capital-Related Costs § 412.322 Indirect medical education adjustment factor. (a) Basic data. CMS.... The indirect teaching adjustment factor equals [e (raised to the power of .2822×the ratio of residents...

  7. A Computational Approach to the Interpretation of Indirect Speech Acts

    NARCIS (Netherlands)

    Beun, R.J.; Eijk, R.M. van; Meyer, J-J.Ch.; Vergunst, N.L.

    2006-01-01

    An Indirect Speech Act (ISA) is an utterance that conveys a message that is different from its literal meaning, often for reasons of politeness or subtlety. The DenK-system provides us with a non-compositional way to look at Indirect Speech Acts that contain modal verbs. We can extract the

  8. Indirect Positive Evidence in the Acquisition of a Subset Grammar

    Science.gov (United States)

    Schwartz, Misha; Goad, Heather

    2017-01-01

    This article proposes that second language learners can use indirect positive evidence (IPE) to acquire a phonological grammar that is a subset of their L1 grammar. IPE is evidence from errors in the learner's L1 made by native speakers of the learner's L2. It has been assumed that subset grammars may be acquired using direct or indirect negative…

  9. The Adoption of Indirect Instruments of Monetary Policy

    OpenAIRE

    Tomás J. T. Baliño; Charles Enoch; William E. Alexander

    1995-01-01

    This paper examines the experience of implementing indirect instruments of monetary policy. The experiences of country studies illustrate the variety of circumstances under which indirect instruments of monetary policy have been introduced. Case Studies are presented for Chile, Egypt, Ghana, Indonesia, Mexico, New Zealand, and Poland.

  10. The Influence of Direct and Indirect Speech on Source Memory

    Directory of Open Access Journals (Sweden)

    Anita Eerland

    2018-02-01

    Full Text Available People perceive the same situation described in direct speech (e.g., John said, “I like the food at this restaurant” as more vivid and perceptually engaging than described in indirect speech (e.g., John said that he likes the food at the restaurant. So, if direct speech enhances the perception of vividness relative to indirect speech, what are the effects of using indirect speech? In four experiments, we examined whether the use of direct and indirect speech influences the comprehender’s memory for the identity of the speaker. Participants read a direct or an indirect speech version of a story and then addressed statements to one of the four protagonists of the story in a memory task. We found better source memory at the level of protagonist gender after indirect than direct speech (Exp. 1–3. When the story was rewritten to make the protagonists more distinctive, we also found an effect of speech type on source memory at the level of the individual, with better memory after indirect than direct speech (Exp. 3–4. Memory for the content of the story, however, was not influenced by speech type (Exp. 4. While previous research showed that direct speech may enhance memory for how something was said, we conclude that indirect speech enhances memory for who said what.

  11. 10 CFR 602.15 - Indirect cost limitations.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Indirect cost limitations. 602.15 Section 602.15 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.15 Indirect cost limitations. Awards issued under this part for conferences and...

  12. 10 CFR 605.16 - Indirect cost limitations.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Indirect cost limitations. 605.16 Section 605.16 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS THE OFFICE OF ENERGY RESEARCH FINANCIAL ASSISTANCE PROGRAM § 605.16 Indirect cost limitations. Awards issued under this part for conferences and scientific...

  13. The indirect radioiodination of vasoactive intestinal peptide

    International Nuclear Information System (INIS)

    Wang Lihua; Li Junling; Yin Duanzhi; Zhang Lei; Zhang Xiuli; Wang Yongxian

    2002-01-01

    Objective: To seek for an effective way to acquire radiolabeled vasoactive intestinal peptide (VIP) with excellent in vivo stability. N-succinimidyl-3-iodo-125-benzoate (S 125 IB) came from radioiodination of N-succinimidyl-3-(tri-n-butylstannyl) benzoate (ATE) precursor and then conjugated with VIP to form 125 IBA-VIP. The labelling procedure was optimized; the in vitro stability and biological activity were evaluated. Methods: 1) Radiolabeling of ATE precursor was achieved with iodogen oxidant and the influential factors were considered in this procedure. The labeling efficiency was determined by thin layer chromatography (TLC) and the purification was carried out by Sep-pak silica gel cartridge. The stability was detected by TLC after 2 h storage in dark at 4 degree C. 2) Conjugation of S 125 IB and VIP. The labelling efficiency was determined with RP TLC and the purification was carried out with high performance liquid chromatography (HPLC, RP C18 column). Trichloroacetic acid (TCA) precipitation method was applied to evaluate the in vitro stability while the biological activity was determined by cell binding experiments with SGC7901 cell lines. Results: 1) S 125 IB experiments. The radioiodination of ATE was performed well for 5 min at 25 degree C with 10 micrograms of iodogen at suitable mole ratio (3-8:1) of ATE/Na 125 I, the labelling efficiency was about 96%. The stability was kept well at 4 degree C in dark, no significant decrease of S 125 IB was observed. 2) The conjugation efficiency of S 125 IB and VIP was above 75% with TLC. HPLC showed the different retention time (t R ) as follows, 125 IBA-VIP: 13.3 min, S 125 IB: 19.6 min, VIP: 8.32 min. The stability of 125 IBA-VIP was better than 125 I-VIP from direct radioiodination of VIP with iodogen oxidant, only 2.85% decrease was found after 7 d at 4 degree C. The biological activity of 125 IBA-VIP was kept as well as 125 I-VIP under the condition of 37 degree C 60 min. Conclusions: The indirect

  14. Indirect Control for Demand Side Management – A Conceptual Introduction

    DEFF Research Database (Denmark)

    Heussen, Kai; You, Shi; Biegel, Benjamin

    2012-01-01

    The concept of “indirect control” has become a relevant discussion term in relation to activation distributed and small-scale demand and generation units to provide resources for power system balancing. The term and its association with price signals has, however caused some confusion as to its...... correct definition, either as a control or a market concept. This paper aims to provide a conceptual introduction to "indirect control" for management of small and distributed demand side resources. A review of control concepts and an analysis of "indirectness" features are provided to create a framework...... for systematic classification of indirect control strategies. The concepts developed then enable a discussion of control performance and valuation of direct- and indirect control strategies....

  15. Smoking Cessation Is Associated With Lower Indirect Costs.

    Science.gov (United States)

    Baker, Christine L; Bruno, Marianna; Emir, Birol; Li, Vicky W; Goren, Amir

    2018-06-01

    This study quantified differences in indirect costs due to decreased work productivity between current and former smokers. Former smokers were further categorized by number of years since quitting to assess corresponding differences. Data on employed individuals were obtained from the 2013 US National Health and Wellness Survey (NHWS; N = 75,000). Indirect costs were calculated for current smokers and former smokers from weekly wages based on age and sex. The annual total indirect costs for current smokers were $1327.53, $1560.18, and $1839.87 higher than for those who quit 0 to 4 years, 5 to 10 years, and more than or equal to 11 years prior, respectively. There were no significant differences in mean total indirect costs between the former smoker groups. Current smokers showed significantly higher total annual indirect costs compared with former smokers, independently of the number of years since quitting smoking.

  16. Forecasting of indirect consumables for a Job Shop

    Science.gov (United States)

    Shakeel, M.; Khan, S.; Khan, W. A.

    2016-08-01

    A job shop has an arrangement where similar machines (Direct consumables) are grouped together and use indirect consumables to produce a product. The indirect consumables include hack saw blades, emery paper, painting brush etc. The job shop is serving various orders at a particular time for the optimal operation of job shop. Forecasting is required to predict the demand of direct and indirect consumables in a job shop. Forecasting is also needed to manage lead time, optimize inventory cost and stock outs. The objective of this research is to obtain the forecast for indirect consumables. The paper shows how job shop can manage their indirect consumables more accurately by establishing a new technique of forecasting. This results in profitable use of job shop by multiple users.

  17. An indecent proposal: the dual functions of indirect speech.

    Science.gov (United States)

    Chakroff, Aleksandr; Thomas, Kyle A; Haque, Omar S; Young, Liane

    2015-01-01

    People often use indirect speech, for example, when trying to bribe a police officer by asking whether there might be "a way to take care of things without all the paperwork." Recent game theoretic accounts suggest that a speaker uses indirect speech to reduce public accountability for socially risky behaviors. The present studies examine a secondary function of indirect speech use: increasing the perceived moral permissibility of an action. Participants report that indirect speech is associated with reduced accountability for unethical behavior, as well as increased moral permissibility and increased likelihood of unethical behavior. Importantly, moral permissibility was a stronger mediator of the effect of indirect speech on likelihood of action, for judgments of one's own versus others' unethical action. In sum, the motorist who bribes the police officer with winks and nudges may not only avoid public punishment but also maintain the sense that his actions are morally permissible. Copyright © 2014 Cognitive Science Society, Inc.

  18. Ultrafast, high repetition rate, ultraviolet, fiber-laser-based source: application towards Yb+ fast quantum-logic.

    Science.gov (United States)

    Hussain, Mahmood Irtiza; Petrasiunas, Matthew Joseph; Bentley, Christopher D B; Taylor, Richard L; Carvalho, André R R; Hope, Joseph J; Streed, Erik W; Lobino, Mirko; Kielpinski, David

    2016-07-25

    Trapped ions are one of the most promising approaches for the realization of a universal quantum computer. Faster quantum logic gates could dramatically improve the performance of trapped-ion quantum computers, and require the development of suitable high repetition rate pulsed lasers. Here we report on a robust frequency upconverted fiber laser based source, able to deliver 2.5 ps ultraviolet (UV) pulses at a stabilized repetition rate of 300.00000 MHz with an average power of 190 mW. The laser wavelength is resonant with the strong transition in Ytterbium (Yb+) at 369.53 nm and its repetition rate can be scaled up using high harmonic mode locking. We show that our source can produce arbitrary pulse patterns using a programmable pulse pattern generator and fast modulating components. Finally, simulations demonstrate that our laser is capable of performing resonant, temperature-insensitive, two-qubit quantum logic gates on trapped Yb+ ions faster than the trap period and with fidelity above 99%.

  19. Frequency-doubled green picosecond laser based on K3B6O10Br nonlinear optical crystal

    Science.gov (United States)

    Meng, Luping; Zhang, Ling; Hou, Zhanyu; Wang, Lirong; Xu, Hui; Shi, Meng; Wang, Lingwu; Yang, Yingying; Qi, Yaoyao; He, Chaojian; Yu, Haijuan; Lin, Xuechun; Su, Fufang; Xia, Mingjun; Li, Rukang

    2018-05-01

    We report a frequency-doubled green picosecond (ps) laser based on K3B6O10Br (KBB) nonlinear optical crystal with cutting angle of θ = 34.7° and φ = 30°. Through intracavity frequency doubling using a type I phase-matched KBB crystal with dimensions of 4 mm × 4 mm × 13.2 mm, the average output power of 185.00 mW green ps laser was obtained with a repetition rate of 80 MHz and pulse width of 25.0 ps. In addition, we present external frequency doubling using KBB crystal. The average output power of 3.00 W green ps laser was generated with a repetition rate of 10 kHz and pulse width of 38.1 ps, which corresponds to a pulse energy of 0.30 mJ and a peak power 7.89 MW, respectively. The experimental results show that KBB crystal is a promising nonlinear optical material.

  20. 2 Gbit/s data transmission from an unfiltered laser-based phosphor-converted white lighting communication system

    KAUST Repository

    Lee, Changmin; Shen, Chao; Oubei, Hassan M.; Cantore, Michael; Janjua, Bilal; Ng, Tien Khee; Farrell, Robert M.; El-Desouki, Munir M.; Speck, James S.; Nakamura, Shuji; Ooi, Boon S.; DenBaars, Steven P.

    2015-01-01

    We demonstrate data transmission of unfiltered white light generated by direct modulation of a blue gallium nitride (GaN) laser diode (LD) exciting YAG:Ce phosphors. 1.1 GHz of modulation bandwidth was measured without a limitation from the slow 3.8 MHz phosphor response. A high data transmission rate of 2 Gbit/s was achieved without an optical blue-filter using a non-return-to-zero on-off keying (NRZ-OOK) modulation scheme. The measured bit error rate (BER) of 3.50 × 10−3 was less than the forward error correction (FEC) limit of 3.8 × 10−3. The generated white light exhibits CIE 1931 chromaticity coordinates of (0.3628, 0.4310) with a color rendering index (CRI) of 58 and a correlated color temperature (CCT) of 4740 K when the LD was operated at 300 mA. The demonstrated laser-based lighting system can be used simultaneously for indoor broadband access and illumination applications with good color stability.

  1. Standoff Methods for the Detection of Threat Agents: A Review of Several Promising Laser-Based Techniques

    Directory of Open Access Journals (Sweden)

    J. Bruce Johnson

    2014-01-01

    Full Text Available Detection of explosives, explosive precursors, or other threat agents presents a number of technological challenges for optical sensing methods. Certainly detecting trace levels of threat agents against a complex background is chief among these challenges; however, the related issues of multiple target distances (from standoff to proximity and sampling time scales (from passive mines to rapid rate of march convoy protection for different applications make it unlikely that a single technique will be ideal for all sensing situations. A number of methods for spanning the range of optical sensor technologies exist which, when integrated, could produce a fused sensor system possessing a high level of sensitivity to threat agents and a moderate standoff real-time capability appropriate for portal screening of personnel or vehicles. In this work, we focus on several promising, and potentially synergistic, laser-based methods for sensing threat agents. For each method, we have briefly outlined the technique and report on the current level of capability.

  2. Watt-level passively Q-switched double-cladding fiber laser based on graphene oxide saturable absorber.

    Science.gov (United States)

    Yu, Zhenhua; Song, Yanrong; Dong, Xinzheng; Li, Yanlin; Tian, Jinrong; Wang, Yonggang

    2013-10-10

    A watt-level passively Q-switched ytterbium-doped double-cladding fiber laser with a graphene oxide (GO) absorber was demonstrated. The structure of the GO saturable absorber mirror (GO-SAM) was of the sandwich type. A maximum output power of 1.8 W was obtained around a wavelength of 1044 nm. To the best of our knowledge, this is the highest output power in Q-switched fiber lasers based on a GO saturable absorber. The pure GO was protected from the oxygen in the air so that the damage threshold of the GO-SAM was effectively raised. The gain fiber was a D-shaped ytterbium-doped double-cladding fiber. The pulse repetition rates were tuned from 120 to 215 kHz with pump powers from 3.89 to 7.8 W. The maximum pulse energy was 8.37 μJ at a pulse width of 1.7 μs.

  3. Electrically driven hybrid Si/III-V Fabry-Pérot lasers based on adiabatic mode transformers.

    Science.gov (United States)

    Ben Bakir, B; Descos, A; Olivier, N; Bordel, D; Grosse, P; Augendre, E; Fulbert, L; Fedeli, J M

    2011-05-23

    We report the first demonstration of an electrically driven hybrid silicon/III-V laser based on adiabatic mode transformers. The hybrid structure is formed by two vertically superimposed waveguides separated by a 100-nm-thick SiO2 layer. The top waveguide, fabricated in an InP/InGaAsP-based heterostructure, serves to provide optical gain. The bottom Si-waveguides system, which supports all optical functions, is constituted by two tapered rib-waveguides (mode transformers), two distributed Bragg reflectors (DBRs) and a surface-grating coupler. The supermodes of this hybrid structure are controlled by an appropriate design of the tapers located at the edges of the gain region. In the middle part of the device almost all the field resides in the III-V waveguide so that the optical mode experiences maximal gain, while in regions near the III-V facets, mode transformers ensure an efficient transfer of the power flow towards Si-waveguides. The investigated device operates under quasi-continuous wave regime. The room temperature threshold current is 100 mA, the side-mode suppression ratio is as high as 20 dB, and the fiber-coupled output power is ~7 mW.

  4. A pilot study using laser-based technique for non-invasive diagnostics of hypertensive conditions in mice

    Science.gov (United States)

    Litvinova, Karina S.; Ahmad, Shakil; Wang, Keqing; Rafailov, Ilya E.; Sokolovski, Sergei G.; Zhang, Lin; Rafailov, Edik U.; Ahmed, Asif

    2016-02-01

    Endothelial dysfunction is directly linked to preeclampsia, a maternal hypertensive condition that is life threating for both the mother and the baby. Epidemiological studies show that women with a history of pre-eclampsia have an elevated risk for cardiovascular disease. Here we report a new non-invasive diagnostic test for preeclampsia in mice that allows us to non-invasively assess the condition of the animals during the experiment and treatment in established models of preeclampsia. A laser-based multifunctional diagnostics system (LAKK-M) was chosen to carry out non-invasive analysis of multiple parameters. The device was used to simultaneously record the microcirculatory blood flow and oxygen saturation, as well as fluorescence levels of endogenous fluorophores. Preliminary experiments were conducted on adenoviral (Ad-)- mediated overexpression of sFlt-1 (Ad-sFlt-1) to mimic preeclampsialike symptoms in mice. The recorded data displayed the ability of the LAKK-M diagnostics device to detect significant differences in perfusion measurements between the control and Ad-sFlt-1 treatment. Preliminary results provide a potential avenue to employ these diagnostics technology to monitor and aid in maintaining control of live animal conditions throughout the experiment and treatment.

  5. Using a laser-based CO2 carbon isotope analyser to investigate gas transfer in geological media

    International Nuclear Information System (INIS)

    Guillon, S.; Pili, E.; Agrinier, P.

    2012-01-01

    CO 2 stable carbon isotopes are very attractive in environmental research to investigate both natural and anthropogenic carbon sources. Laser-based CO 2 carbon isotope analysis provides continuous measurement at high temporal resolution and is a promising alternative to isotope ratio mass spectrometry (IRMS). We performed a thorough assessment of a commercially available CO 2 Carbon Isotope Analyser (CCIA DLT-100, Los Gatos Research) that allows in situ measurement of C-13 in CO 2 . Using a set of reference gases of known CO 2 concentration and carbon isotopic composition, we evaluated the precision, long-term stability, temperature sensitivity and concentration dependence of the analyser. Despite good precision calculated from Allan variance (5.0 ppm for CO 2 concentration, and 0.05 per thousand for δC-13 at 60 s averaging), real performances are altered by two main sources of error: temperature sensitivity and dependence of C-13 on CO 2 concentration. Data processing is required to correct for these errors. Following application of these corrections, we achieve an accuracy of 8.7 ppm for CO 2 concentration and 1.3 per thousand for δC-13, which is worse compared to mass spectrometry performance, but still allowing field applications. With this portable analyser we measured CO 2 flux degassed from rock in an underground tunnel. The obtained carbon isotopic composition agrees with IRMS measurement, and can be used to identify the carbon source. (authors)

  6. Fiber-laser-based, green-pumped, picosecond optical parametric oscillator using fan-out grating PPKTP.

    Science.gov (United States)

    Chaitanya Kumar, S; Parsa, S; Ebrahim-Zadeh, M

    2016-01-01

    We report a stable, Yb-fiber-laser-based, green-pumped, picosecond optical parametric oscillator (OPO) for the near-infrared based on periodically poled potassium titanyl phosphate (PPKTP) nonlinear crystal, using fan-out grating design and operating near room temperature. The OPO is continuously tunable across 726-955 nm in the signal and 1201-1998 nm in the idler, resulting in a total signal plus idler wavelength coverage of 1026 nm by grating tuning at a fixed temperature. The device generates up to 580 mW of average power in the signal at 765 nm and 300 mW in the idler at 1338 nm, with an overall extraction efficiency of up to 52% and a pump depletion >76%. The extracted signal at 765 nm and idler at 1746 nm exhibit excellent passive power stability better than 0.5% and 0.8% rms, respectively, over 1 h with good beam quality in TEM00 mode profile. The output signal pulses have a Gaussian temporal duration of 13.2 ps, with a FWHM spectral bandwidth of 3.4 nm at 79.5 MHz repetition rate. Power scaling limitations of the OPO due to the material properties of PPKTP are studied.

  7. 2 Gbit/s data transmission from an unfiltered laser-based phosphor-converted white lighting communication system

    KAUST Repository

    Lee, Changmin

    2015-11-05

    We demonstrate data transmission of unfiltered white light generated by direct modulation of a blue gallium nitride (GaN) laser diode (LD) exciting YAG:Ce phosphors. 1.1 GHz of modulation bandwidth was measured without a limitation from the slow 3.8 MHz phosphor response. A high data transmission rate of 2 Gbit/s was achieved without an optical blue-filter using a non-return-to-zero on-off keying (NRZ-OOK) modulation scheme. The measured bit error rate (BER) of 3.50 × 10−3 was less than the forward error correction (FEC) limit of 3.8 × 10−3. The generated white light exhibits CIE 1931 chromaticity coordinates of (0.3628, 0.4310) with a color rendering index (CRI) of 58 and a correlated color temperature (CCT) of 4740 K when the LD was operated at 300 mA. The demonstrated laser-based lighting system can be used simultaneously for indoor broadband access and illumination applications with good color stability.

  8. Effect of size and geometry of gold nanostructures in performance of laser-based hyperthermia: a multiscale- multiphysics modelling

    International Nuclear Information System (INIS)

    Samadinia, Hossein; Rafii-Tabar, Hashem; Sasanpour, Pezhman; Razaghi, Mohammad Reza; Nezhad, Mohammadreza Hormozi

    2016-01-01

    The importance of hyperthermia as a promising method in disruption and removal of cancerous cells is well understood. One of the effective options of concentration of heat within a specific tissue is using laser and exploiting absorption properties of metallic nanostructures. In this report, the geometrical effect of gold nanostructures in the performance of laser based hyperthermia has been analyzed. The analysis is based on the consideration of absorption properties of gold nanostructures, interaction of laser light with a specific tissue containing nanostructures and the effect of generated heat on elevation of temperature inside the tissue. The analysis is performed using Mie theory (for extraction of absorption/scattering properties of nanostructures), Monte Carlo (MC) (interaction of light inside the tissue) and solving the heat equation (considering the elevation of temperature inside the tissue). We have compared the effect of a laser beam on the maximum temperature inside the tissue and the results indicate that focusing the beam size of the laser to half width will culminate in a 50% elevation of maximum temperature in the tissue, while the average temperature raise inside the tissue will not be altered. (paper)

  9. Ultra-photo-stable coherent random laser based on liquid waveguide gain channels doped with boehmite nanosheets

    Science.gov (United States)

    Zhang, Hua; Zhang, Hong; Yang, Chao; Dai, Jiangyun; Yin, Jiajia; Xue, Hongyan; Feng, Guoying; Zhou, Shouhuan

    2018-02-01

    Construction of ultra-photo-stable coherent random laser based on liquid waveguide gain channels doped with boehmite nanosheets has been demonstrated. An Al plate uniformly coated with boehmite nanosheets was prepared by an alkali-treatment method and used as a scattering surface for the coherent random laser. Microcavity may be formed between these boehmite nanosheets owing to the strong optical feedback induced by the multiple light scattering. Many sharp peaks are observed in the emission spectra, and their laser thresholds are different, which confirms the feedback mechanism is coherent. The linewidth of the main peak at 571.74 nm is 0.28 nm, and the threshold of the main peak is about 4.96 mJ/cm2. Due to the fluidity of liquid waveguide gain medium, the photostability of this coherent random laser is better than the conventional solid state dye random lasers. The emission direction is well constrained by the waveguide effect within a certain angular range (±30°). This kind of coherent random laser can be applied in optical fluid lasers and photonic devices.

  10. An improved recommendation algorithm via weakening indirect linkage effect

    International Nuclear Information System (INIS)

    Chen Guang; Qiu Tian; Shen Xiao-Quan

    2015-01-01

    We propose an indirect-link-weakened mass diffusion method (IMD), by considering the indirect linkage and the source object heterogeneity effect in the mass diffusion (MD) recommendation method. Experimental results on the MovieLens, Netflix, and RYM datasets show that, the IMD method greatly improves both the recommendation accuracy and diversity, compared with a heterogeneity-weakened MD method (HMD), which only considers the source object heterogeneity. Moreover, the recommendation accuracy of the cold objects is also better elevated in the IMD than the HMD method. It suggests that eliminating the redundancy induced by the indirect linkages could have a prominent effect on the recommendation efficiency in the MD method. (paper)

  11. Types of suggestibility: Relationships among compliance, indirect, and direct suggestibility.

    Science.gov (United States)

    Polczyk, Romuald; Pasek, Tomasz

    2006-10-01

    It is commonly believed that direct suggestibility, referring to overt influence, and indirect suggestibility, in which the intention to influence is hidden, correlate poorly. This study demonstrates that they are substantially related, provided that they tap similar areas of influence. Test results from 103 students, 55 women and 48 men, were entered into regression analyses. Indirect suggestibility, as measured by the Sensory Suggestibility Scale for Groups, and compliance, measured by the Gudjonsson Compliance Scale, were predictors of direct suggestibility, assessed with the Barber Suggestibility Scale. Spectral analyses showed that indirect suggestibility is more related to difficult tasks on the BSS, but compliance is more related to easy tasks on this scale.

  12. Indirect Taxes in Romania – an Econometric Analysis

    Directory of Open Access Journals (Sweden)

    Daniela Penu

    2016-03-01

    Full Text Available Indirect taxes have a significant weight in the GDP. Statistical data reveals that the new states that joined the EU in its funding sources to the greatest extent through indirect taxes. They reveal, on the one hand, reducing the tax burden on the producer, and on the other hand, the difficulty faced by the country in direct tax collection, but also some problems of social nature. This article proposes an econometric analysis of the relationship between indirect taxes and household final consumption expenditure.

  13. Indirect Genetic Effects for group-housed animals

    DEFF Research Database (Denmark)

    Alemu, Setegn Worku

    This thesis investigated social interactions in group-housed animals. The main findings of this thesis: 1) Statistical methods to estimate indirect genetic effects when interactions differ between kin vs. non-kin were developed. 2) Indirect genetic effects contribute a substantial amount...... of heritable variation for bite mark traits in group-housed min. 3) Indirect genetic effects estimation needs to take into account systematic interactions due to sex or kin for bite mark trait in group-housed min. 4) Genomic selection can be used to increase the response to selection for survival time in Brown...

  14. Indirect Inference for Stochastic Differential Equations Based on Moment Expansions

    KAUST Repository

    Ballesio, Marco; Tempone, Raul; Vilanova, Pedro

    2016-01-01

    We provide an indirect inference method to estimate the parameters of timehomogeneous scalar diffusion and jump diffusion processes. We obtain a system of ODEs that approximate the time evolution of the first two moments of the process

  15. An Indirect Assessment of the War Against Iraq

    National Research Council Canada - National Science Library

    Ferguson Jr, C. M

    1992-01-01

    ...? General Schwartzkopf's statement of intent reveals that his strategy for the conduct of operations reflected an appreciation for the "indirect approach," of Sun Tzu and his erstwhile protege, B. H. Liddell-Hart...

  16. Separating astrophysical sources from indirect dark matter signals

    Science.gov (United States)

    Siegal-Gaskins, Jennifer M.

    2015-01-01

    Indirect searches for products of dark matter annihilation and decay face the challenge of identifying an uncertain and subdominant signal in the presence of uncertain backgrounds. Two valuable approaches to this problem are (i) using analysis methods which take advantage of different features in the energy spectrum and angular distribution of the signal and backgrounds and (ii) more accurately characterizing backgrounds, which allows for more robust identification of possible signals. These two approaches are complementary and can be significantly strengthened when used together. I review the status of indirect searches with gamma rays using two promising targets, the Inner Galaxy and the isotropic gamma-ray background. For both targets, uncertainties in the properties of backgrounds are a major limitation to the sensitivity of indirect searches. I then highlight approaches which can enhance the sensitivity of indirect searches using these targets. PMID:25304638

  17. Indirect Monetary Policy Reforms and Output Growth in Nigeria: An ...

    African Journals Online (AJOL)

    BRRE). The efforts in repositioning these banks through the current banking reforms (recapitalization and consolidation) the paper notes are a right step in the right direction. Keywords: Indirect monetary policy, Granger – causality, output growth

  18. Indirect inference with time series observed with error

    DEFF Research Database (Denmark)

    Rossi, Eduardo; Santucci de Magistris, Paolo

    estimation. We propose to solve this inconsistency by jointly estimating the nuisance and the structural parameters. Under standard assumptions, this estimator is consistent and asymptotically normal. A condition for the identification of ARMA plus noise is obtained. The proposed methodology is used......We analyze the properties of the indirect inference estimator when the observed series are contaminated by measurement error. We show that the indirect inference estimates are asymptotically biased when the nuisance parameters of the measurement error distribution are neglected in the indirect...... to estimate the parameters of continuous-time stochastic volatility models with auxiliary specifications based on realized volatility measures. Monte Carlo simulations shows the bias reduction of the indirect estimates obtained when the microstructure noise is explicitly modeled. Finally, an empirical...

  19. RESEMBLANCE OF INDIRECTNESS IN POLITENESS OF EFL LEARNERS’ REQUEST REALIZATIONS

    Directory of Open Access Journals (Sweden)

    Indawan Syahri

    2013-07-01

    Full Text Available Abstract: Politeness principles are universally utilized by the speakers of any language when realizing various speech acts. However, the speakers of particular languages relatively apply politeness due to the cultural norms embedded. The present study attempts to delineate how the Indonesian learners of English (ILE apply the politeness principles in request realizations. Specifically it devotes to the types of politeness strategies applied and resemblance of the indirectness in politeness strategies in requesting acts. The FTAs and indirectness are the theoretical bases used to trace the typologies of both politeness and request strategies. The data werere collected by means of certain elicitation techniques, i.e. DCTs and Role-plays. The analyses werere done through three stages; determining request strategies, politeness strategies, and resemblance of indirectness in politeness. The results show that the indirectness generally is parallel to politeness. Besides, some pragmatic transfers are found in terms of applying native-culture norms in realizing target speech acts.

  20. Inducible indirect defence of plants : from mechanisms to ecological functions

    NARCIS (Netherlands)

    Dicke, M.; Poecke, van R.M.P.; Boer, de J.G.

    2003-01-01

    Inducible defences allow plants to be phenotypically plastic. Inducible indirect defence of plants by attracting carnivorous enemies of herbivorous arthropods can vary with plant species and genotype, with herbivore species or instar and potentially with other environmental conditions. So far,

  1. Comparative analysis of direct and indirect property investment ...

    African Journals Online (AJOL)

    Comparative analysis of direct and indirect property investment returns in Abuja. ... in property shares is more risky than commercial property due to the risk ... of the stock market, it was discovered that there is a strong positive relationship ...

  2. Indirect reciprocity and the evolution of "moral signals"

    Science.gov (United States)

    Smead, Rory

    2010-01-01

    Signals regarding the behavior of others are an essential element of human moral systems and there are important evolutionary connections between language and large-scale cooperation. In particular, social communication may be required for the reputation tracking needed to stabilize indirect reciprocity. Additionally, scholars have suggested that the benefits of indirect reciprocity may have been important for the evolution of language and that social signals may have coevolved with large-scale cooperation. This paper investigates the possibility of such a coevolution. Using the tools of evolutionary game theory, we present a model that incorporates primitive "moral signaling" into a simple setting of indirect reciprocity. This model reveals some potential difficulties for the evolution of "moral signals." We find that it is possible for "moral signals" to evolve alongside indirect reciprocity, but without some external pressure aiding the evolution of a signaling system, such a coevolution is unlikely.

  3. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  4. Ancestry of indirect techniques for X-ray imaging

    International Nuclear Information System (INIS)

    Mertz, L.

    1989-01-01

    Historical citations concerning the origins of coded-aperture imaging are corrected. Another scheme is presented for synthetic indirect imaging to overcome certain shortcomings of simple coded apertures. Pairs of Fresnel zone patterns are used to create moire patterns that can be Fourier transformed for image reconstruction. It is also conjectured that image reconstructions that are constrained to be nonnegative should overcome certain complaints concerning indirect imaging. 20 refs

  5. The indirect costs and benefits of greenhouse gas mitigation

    International Nuclear Information System (INIS)

    Markandya, A.

    1998-01-01

    The indirect costs of GHG projects are very important in the evaluation of such projects. In many cases they are more important than the direct costs. This paper has shown what such costs consist of and how they may be estimated. As countries prepare their mitigation strategies, it is very important that they develop tools for the assessment of these indirect costs and use these tools in the appropriate manner. Hopefully, this paper will point them in the right direction. (au) 11 refs

  6. The Indirect Costs of Financial Distress in Indonesia

    OpenAIRE

    Wijantini, Wijantini

    2007-01-01

    This paper presents quantitative estimates of the indirect cost of financial distress and its determinants. In order to measure the cost, this study estimates the annualized changes in industry-adjusted operation profit and sales from a year before the onset of distress to the resolution year. Using those approaches, the median of indirect financial distress cost is estimated between three and 11 percent annually. To the extent that the direct cost of financial distress reduces reported opera...

  7. Light indirectly mediates bivalve habitat modification and impacts on seagrass

    DEFF Research Database (Denmark)

    Castorani, Max C. N.; Glud, Ronnie; Hasler-Sheetal, Harald

    2015-01-01

    Environmental context may influence the sign, strength, andmechanisms of species interactions but few studies have experimentally tested the potential for abiotic conditions to mediate interactions through multiple cooccurring stress pathways. Abiotic conditionsmay mediate species interactions...... by directly or indirectly influencing the effects of habitat-modifying organisms that are capable of simultaneously ameliorating and exacerbating multiple stressors. Itwas hypothesized that light availability changes seagrassmetabolismand thereby indirectly regulates bivalve habitat modification...

  8. Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators.

    Science.gov (United States)

    Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi; Minoshima, Kaoru

    2013-09-01

    A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

  9. Manifestation of Aerosol Indirect Effects in Arctic Clouds

    Science.gov (United States)

    Lubin, D.; Vogelmann, A. M.

    2009-12-01

    The first aerosol indirect effect has traditionally been conceived as an enhancement of shortwave cloud reflectance in response to decreased effective droplet size at fixed liquid water path, as cloud nucleating aerosol becomes entrained in the cloud. The high Arctic, with its pervasive low-level stratiform cloud cover and frequent episodes of anthropogenic aerosol (Artic "haze"), has in recent years served as a natural laboratory for research on actual manifestations of aerosol indirect effects. This paper will review the surprising set of developments: (1) the detection of the indirect effect as a source of surface warming, rather than cooling, throughout early spring, (2) a transition to a cooling effect in late spring, corresponding to the beginning of the sea ice melt season, and (3) detection of an indirect effect during summer, outside of the "Arctic haze" season. This paper will also discuss measurements of spectral shortwave irradiance (350-2200 nm) made at Barrow, Alaska, during the U.S. Department of Energy's Indirect and Semi-Direct Aerosol Campaign (ISDAC), which reveal complications in our conception of the indirect effect related to the ice phase in Arctic stratiform clouds.

  10. Heard it through the grapevine: indirect networks and employee creativity.

    Science.gov (United States)

    Hirst, Giles; Van Knippenberg, Daan; Zhou, Jing; Quintane, Eric; Zhu, Cherrie

    2015-03-01

    Social networks can be important sources of information and insights that may spark employee creativity. The cross-fertilization of ideas depends not just on access to information and insights through one's direct network-the people one actually interacts with--but at least as much on access to the indirect network one's direct ties connect one to (i.e., people one does not interact with directly, but with whom one's direct ties interact). We propose that the reach efficiency of this indirect network--its nonredundancy in terms of interconnections--is positively related to individual creativity. To help specify the boundaries of this positive influence of the indirect network, we also explore how many steps removed the indirect network still adds to creativity. In addition, we propose that the efficiency (nonredundancy) of one's direct network is important here, because more efficient direct networks give one access to indirect networks with greater reach efficiency. Our hypotheses were supported in a multilevel analysis of multisource survey data from 223 sales representatives nested within 11 divisions of a Chinese pharmaceutical company. This analysis also showed that the creative benefits of reach efficiency were evident for 3 and 4 degrees of separation but were greatest for indirect ties that depend only on one's direct ties. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  11. Indirect methods for reference interval determination - review and recommendations.

    Science.gov (United States)

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  12. Preschool children's behavioral tendency toward social indirect reciprocity.

    Directory of Open Access Journals (Sweden)

    Mayuko Kato-Shimizu

    Full Text Available Social indirect reciprocity seems to be crucial in enabling large-scale cooperative networks among genetically unrelated individuals in humans. However, there are relatively few studies on social indirect reciprocity in children compared to adults. Investigating whether young children have a behavioral tendency toward social indirect reciprocity will help us understand how and when the fundamental ability to form cooperative relationships among adults is acquired. Using naturalistic observation at a nursery school, this study examined whether 5- to 6-year-olds show a behavioral tendency to engage in social indirect reciprocity in response to their peers' prosocial behavior toward a third party. The results revealed that bystander children tended to display prosocial behavior toward their peers more frequently after observing these peers' prosocial behavior toward third-party peers, compared with control situations; this suggests that 5- to 6-year-olds may have an essential behavioral tendency to establish social indirect reciprocity when interacting with peers in their daily lives. In addition, bystanders tended to display affiliative behavior after observing focal children's prosocial behavior. In other words, observing peers' prosocial behavior toward third-party peers evoked bystanders' positive emotions toward the helpers. Considering both the present results and previous findings, we speculate that in preschoolers, such positive emotions might mediate the increase in the bystander's prosocial behavior toward the helper. In addition, an intuitional emotional process plays an important role in the preschooler's behavioral tendency toward social indirect reciprocity in natural interactions with peers.

  13. Preschool children's behavioral tendency toward social indirect reciprocity.

    Science.gov (United States)

    Kato-Shimizu, Mayuko; Onishi, Kenji; Kanazawa, Tadahiro; Hinobayashi, Toshihiko

    2013-01-01

    Social indirect reciprocity seems to be crucial in enabling large-scale cooperative networks among genetically unrelated individuals in humans. However, there are relatively few studies on social indirect reciprocity in children compared to adults. Investigating whether young children have a behavioral tendency toward social indirect reciprocity will help us understand how and when the fundamental ability to form cooperative relationships among adults is acquired. Using naturalistic observation at a nursery school, this study examined whether 5- to 6-year-olds show a behavioral tendency to engage in social indirect reciprocity in response to their peers' prosocial behavior toward a third party. The results revealed that bystander children tended to display prosocial behavior toward their peers more frequently after observing these peers' prosocial behavior toward third-party peers, compared with control situations; this suggests that 5- to 6-year-olds may have an essential behavioral tendency to establish social indirect reciprocity when interacting with peers in their daily lives. In addition, bystanders tended to display affiliative behavior after observing focal children's prosocial behavior. In other words, observing peers' prosocial behavior toward third-party peers evoked bystanders' positive emotions toward the helpers. Considering both the present results and previous findings, we speculate that in preschoolers, such positive emotions might mediate the increase in the bystander's prosocial behavior toward the helper. In addition, an intuitional emotional process plays an important role in the preschooler's behavioral tendency toward social indirect reciprocity in natural interactions with peers.

  14. Progress Toward Measuring CO2 Isotopologue Fluxes in situ with the LLNL Miniature, Laser-based CO2 Sensor

    Science.gov (United States)

    Osuna, J. L.; Bora, M.; Bond, T.

    2015-12-01

    One method to constrain photosynthesis and respiration independently at the ecosystem scale is to measure the fluxes of CO2­ isotopologues. Instrumentation is currently available to makes these measurements but they are generally costly, large, bench-top instruments. Here, we present progress toward developing a laser-based sensor that can be deployed directly to a canopy to passively measure CO2 isotopologue fluxes. In this study, we perform initial proof-of-concept and sensor characterization tests in the laboratory and in the field to demonstrate performance of the Lawrence Livermore National Laboratory (LLNL) tunable diode laser flux sensor. The results shown herein demonstrate measurement of bulk CO2 as a first step toward achieving flux measurements of CO2 isotopologues. The sensor uses a Vertical Cavity Surface Emitting Laser (VCSEL) in the 2012 nm range. The laser is mounted in a multi-pass White Cell. In order to amplify the absorption signal of CO2 in this range we employ wave modulation spectroscopy, introducing an alternating current (AC) bias component where f is the frequency of modulation on the laser drive current in addition to the direct current (DC) emission scanning component. We observed a strong linear relationship (r2 = 0.998 and r2 = 0.978 at all and low CO2 concentrations, respectively) between the 2f signal and the CO2 concentration in the cell across the range of CO2 concentrations relevant for flux measurements. We use this calibration to interpret CO2 concentration of a gas flowing through the White cell in the laboratory and deployed over a grassy field. We will discuss sensor performance in the lab and in situ as well as address steps toward achieving canopy-deployed, passive measurements of CO2 isotopologue fluxes. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-675788

  15. Improved laser-based triangulation sensor with enhanced range and resolution through adaptive optics-based active beam control.

    Science.gov (United States)

    Reza, Syed Azer; Khwaja, Tariq Shamim; Mazhar, Mohsin Ali; Niazi, Haris Khan; Nawab, Rahma

    2017-07-20

    Various existing target ranging techniques are limited in terms of the dynamic range of operation and measurement resolution. These limitations arise as a result of a particular measurement methodology, the finite processing capability of the hardware components deployed within the sensor module, and the medium through which the target is viewed. Generally, improving the sensor range adversely affects its resolution and vice versa. Often, a distance sensor is designed for an optimal range/resolution setting depending on its intended application. Optical triangulation is broadly classified as a spatial-signal-processing-based ranging technique and measures target distance from the location of the reflected spot on a position sensitive detector (PSD). In most triangulation sensors that use lasers as a light source, beam divergence-which severely affects sensor measurement range-is often ignored in calculations. In this paper, we first discuss in detail the limitations to ranging imposed by beam divergence, which, in effect, sets the sensor dynamic range. Next, we show how the resolution of laser-based triangulation sensors is limited by the interpixel pitch of a finite-sized PSD. In this paper, through the use of tunable focus lenses (TFLs), we propose a novel design of a triangulation-based optical rangefinder that improves both the sensor resolution and its dynamic range through adaptive electronic control of beam propagation parameters. We present the theory and operation of the proposed sensor and clearly demonstrate a range and resolution improvement with the use of TFLs. Experimental results in support of our claims are shown to be in strong agreement with theory.

  16. UV-laser-based microscopic dissection of tree rings - a novel sampling tool for δ(13) C and δ(18) O studies.

    Science.gov (United States)

    Schollaen, Karina; Heinrich, Ingo; Helle, Gerhard

    2014-02-01

    UV-laser-based microscopic systems were utilized to dissect and sample organic tissue for stable isotope measurements from thin wood cross-sections. We tested UV-laser-based microscopic tissue dissection in practice for high-resolution isotopic analyses (δ(13) C/δ(18) O) on thin cross-sections from different tree species. The method allows serial isolation of tissue of any shape and from millimetre down to micrometre scales. On-screen pre-defined areas of interest were automatically dissected and collected for mass spectrometric analysis. Three examples of high-resolution isotopic analyses revealed that: in comparison to δ(13) C of xylem cells, woody ray parenchyma of deciduous trees have the same year-to-year variability, but reveal offsets that are opposite in sign depending on whether wholewood or cellulose is considered; high-resolution tree-ring δ(18) O profiles of Indonesian teak reflect monsoonal rainfall patterns and are sensitive to rainfall extremes caused by ENSO; and seasonal moisture signals in intra-tree-ring δ(18) O of white pine are weighted by nonlinear intra-annual growth dynamics. The applications demonstrate that the use of UV-laser-based microscopic dissection allows for sampling plant tissue at ultrahigh resolution and unprecedented precision. This new technique facilitates sampling for stable isotope analysis of anatomical plant traits like combined tree eco-physiological, wood anatomical and dendroclimatological studies. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  17. Direct and indirect effects of body weight on adult wages.

    Science.gov (United States)

    Han, Euna; Norton, Edward C; Powell, Lisa M

    2011-12-01

    Previous estimates of the association between body weight and wages in the literature have been conditional on education and occupation. In addition to the effect of current body weight status (body mass index (BMI) or obesity) on wages, this paper examines the indirect effect of body weight status in the late-teenage years on wages operating through education and occupation choice. Using the National Longitudinal Survey of Youth 1979 data, for women, we find that a one-unit increase in BMI is directly associated with 1.83% lower hourly wages whereas the indirect BMI wage penalty is not statistically significant. Neither a direct nor an indirect BMI wage penalty is found for men. However, results based on clinical weight classification reveal that the indirect wage penalty occurs to a larger extent at the upper tail of the BMI distribution for both men and women via the pathways of education and occupation outcomes. Late-teen obesity is indirectly associated with 3.5% lower hourly wages for both women and men. These results are important because they imply that the total effect of obesity on wages is significantly larger than has been estimated in previous cross-sectional studies. 2011 Elsevier B.V. All rights reserved.

  18. Selection for components of complex characteristics - indirect selection

    International Nuclear Information System (INIS)

    Haensel, H.

    1984-01-01

    A hierarchy of complexity exists in plant characteristics. The efficiency of indirect selection for a complex characteristic by a sub-trait depends on the heritability of the complex characteristic (hsub(c)), the heritability of the sub-trait (hsub(s)), and the genotypic correlation between sub-trait and complex characteristic (rsub(s.c)). In 1961 hsub(s)Xrsub(s.c)>hsub(c) was postulated, when indirect selection becomes more efficient than direct selection. Numerical examples for this relationship are given and a table for indirect selection for yield in wheat is elaborated. Efficiency ranking of sub-traits in indirect selection may change with climate, conditions of cultivation, the level of other sub-traits, the level of the complex characteristic already reached by breeding, and the breeding material. An example shows that regression analysis for different sub-traits on the same complex characteristic, and an estimation of the differences of the within - and the between - variety slopes, may help to select the more efficient sub-trait. In another example, where simultaneous selection was made for two polygenic characteristics, one directly and the other indirectly by two sub-traits, less than half the F 5 -lines had to be continued, when using the more efficient sub-trait. (author)

  19. Supporting Risk Assessment: Accounting for Indirect Risk to Ecosystem Components.

    Directory of Open Access Journals (Sweden)

    Cathryn Clarke Murray

    Full Text Available The multi-scalar complexity of social-ecological systems makes it challenging to quantify impacts from human activities on ecosystems, inspiring risk-based approaches to assessments of potential effects of human activities on valued ecosystem components. Risk assessments do not commonly include the risk from indirect effects as mediated via habitat and prey. In this case study from British Columbia, Canada, we illustrate how such "indirect risks" can be incorporated into risk assessments for seventeen ecosystem components. We ask whether (i the addition of indirect risk changes the at-risk ranking of the seventeen ecosystem components and if (ii risk scores correlate with trophic prey and habitat linkages in the food web. Even with conservative assumptions about the transfer of impacts or risks from prey species and habitats, the addition of indirect risks in the cumulative risk score changes the ranking of priorities for management. In particular, resident orca, Steller sea lion, and Pacific herring all increase in relative risk, more closely aligning these species with their "at-risk status" designations. Risk assessments are not a replacement for impact assessments, but-by considering the potential for indirect risks as we demonstrate here-they offer a crucial complementary perspective for the management of ecosystems and the organisms within.

  20. Supporting Risk Assessment: Accounting for Indirect Risk to Ecosystem Components

    Science.gov (United States)

    Mach, Megan E.; Martone, Rebecca G.; Singh, Gerald G.; O, Miriam; Chan, Kai M. A.

    2016-01-01

    The multi-scalar complexity of social-ecological systems makes it challenging to quantify impacts from human activities on ecosystems, inspiring risk-based approaches to assessments of potential effects of human activities on valued ecosystem components. Risk assessments do not commonly include the risk from indirect effects as mediated via habitat and prey. In this case study from British Columbia, Canada, we illustrate how such “indirect risks” can be incorporated into risk assessments for seventeen ecosystem components. We ask whether (i) the addition of indirect risk changes the at-risk ranking of the seventeen ecosystem components and if (ii) risk scores correlate with trophic prey and habitat linkages in the food web. Even with conservative assumptions about the transfer of impacts or risks from prey species and habitats, the addition of indirect risks in the cumulative risk score changes the ranking of priorities for management. In particular, resident orca, Steller sea lion, and Pacific herring all increase in relative risk, more closely aligning these species with their “at-risk status” designations. Risk assessments are not a replacement for impact assessments, but—by considering the potential for indirect risks as we demonstrate here—they offer a crucial complementary perspective for the management of ecosystems and the organisms within. PMID:27632287

  1. Indirect reciprocity in three types of social dilemmas.

    Science.gov (United States)

    Nakamura, Mitsuhiro; Ohtsuki, Hisashi

    2014-08-21

    Indirect reciprocity is a key mechanism for the evolution of human cooperation. Previous studies explored indirect reciprocity in the so-called donation game, a special class of Prisoner's Dilemma (PD) with unilateral decision making. A more general class of social dilemmas includes Snowdrift (SG), Stag Hunt (SH), and PD games, where two players perform actions simultaneously. In these simultaneous-move games, moral assessments need to be more complex; for example, how should we evaluate defection against an ill-reputed, but now cooperative, player? We examined indirect reciprocity in the three social dilemmas and identified twelve successful social norms for moral assessments. These successful norms have different principles in different dilemmas for suppressing cheaters. To suppress defectors, any defection against good players is prohibited in SG and PD, whereas defection against good players may be allowed in SH. To suppress unconditional cooperators, who help anyone and thereby indirectly contribute to jeopardizing indirect reciprocity, we found two mechanisms: indiscrimination between actions toward bad players (feasible in SG and PD) or punishment for cooperation with bad players (effective in any social dilemma). Moreover, we discovered that social norms that unfairly favor reciprocators enhance robustness of cooperation in SH, whereby reciprocators never lose their good reputation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Circumventing resistance: using values to indirectly change attitudes.

    Science.gov (United States)

    Blankenship, Kevin L; Wegener, Duane T; Murray, Renee A

    2012-10-01

    Most research on persuasion examines messages that directly address the attitude of interest. However, especially when message recipients are inclined to resist change, indirect methods might be more effective. Because values are rarely attacked and defended, value change could serve as a useful indirect route for attitude change. Attitudes toward affirmative action changed more when the value of equality was attacked (indirect change) than when affirmative action was directly attacked using the same message (Experiments 1-2). Changes in confidence in the value were responsible for the indirect change when the value was attacked (controlling for changes in favorability toward the value), whereas direct counterarguments to the message were responsible for the relative lack of change when the attitude was attacked directly (Experiment 2). Attacking the value of equality influenced attitudes toward policies related to the value but left policy attitudes unrelated to the value unchanged (Experiment 3). Finally, a manipulation of value confidence that left attitudes toward the value intact demonstrated similar confidence-based influences on policies related to the value of freedom (Experiment 4). Undermined value confidence also resulted in less confidence in the resulting policy attitudes controlling for the changes in the policy attitudes themselves (Experiments 3 and 4). Therefore, indirect change through value attacks presented a double threat--to both the policy attitudes and the confidence with which those policy attitudes were held (potentially leaving them open to additional influence).

  3. High performance 40-stage and 15-stage quantum cascade lasers based on two-material active region composition

    Science.gov (United States)

    Figueiredo, P.; Suttinger, M.; Go, R.; Todi, A.; Shu, Hong; Tsvid, E.; Patel, C. Kumar N.; Lyakh, A.

    2017-05-01

    5.6μm quantum cascade lasers based on Al0.78In0.22As/In0.69Ga0.31As active region composition with measured pulsed room temperature wall plug efficiency of 28.3% are reported. Injection efficiency for the upper laser level of 75% was measured by testing devices with variable cavity length. Threshold current density of 1.7kA/cm2 and slope efficiency of 4.9W/A were measured for uncoated 3.15mm x 9µm lasers. Threshold current density and slope efficiency dependence on temperature in the range from 288K to 348K can be described by characteristic temperatures T0 140K and T1 710K, respectively. Pulsed slope efficiency, threshold current density, and wallplug efficiency for a 2.1mm x 10.4µm 15-stage device with the same design and a high reflection-coated back facet were measured to be 1.45W/A, 3.1kA/cm2 , and 18%, respectively. Continuous wave values for the same parameters were measured to be 1.42W/A, 3.7kA/cm2 , and 12%. Continuous wave optical power levels exceeding 0.5W per millimeter of cavity length was demonstrated. When combined with the 40-stage device data, the inverse slope efficiency dependence on cavity length for 15-stage data allowed for separate evaluation of the losses originating from the active region and from the cladding layers of the laser structure. Specifically, the active region losses for the studied design were found to be 0.77cm-1, while cladding region losses - 0.33cm-1. The data demonstrate that active region losses in mid wave infrared quantum cascade lasers largely define total waveguide losses and that their reduction should be one of the main priorities in the quantum cascade laser design.

  4. Isotope Enrichment Detection by Laser Ablation - Laser Absorption Spectrometry: Automated Environmental Sampling and Laser-Based Analysis for HEU Detection

    International Nuclear Information System (INIS)

    Anheier, Norman C.; Bushaw, Bruce A.

    2010-01-01

    signals on a shot-to-shot basis. The media is translated by a micron resolution scanning system, allowing the isotope analysis to cover the entire sample surface. We also report, to the best of our knowledge, the first demonstration of laser-based isotopic measurements on individual micron-sized particles that are minor target components in a much larger heterogeneous mix of 'background' particles. This composition is consistent with swipe and environmental aerosol samples typically collected for safeguards ES purposes. Single-shot detection sensitivity approaching the femtogram range and relative isotope abundance uncertainty better than 10% has been demonstrated using gadolinium isotopes as surrogate materials.

  5. Direct and Indirect Effects of PM on the Cardiovascular System

    Science.gov (United States)

    Nelin, Timothy D.; Joseph, Allan M.; Gorr, Matthew W.; Wold, Loren E.

    2011-01-01

    Human exposure to particulate matter (PM) elicits a variety of responses on the cardiovascular system through both direct and indirect pathways. Indirect effects of PM on the cardiovascular system are mediated through the autonomic nervous system, which controls heart rate variability, and inflammatory responses, which augment acute cardiovascular events and atherosclerosis. Recent research demonstrates that PM also affects the cardiovascular system directly by entry into the systemic circulation. This process causes myocardial dysfunction through mechanisms of reactive oxygen species production, calcium ion interference, and vascular dysfunction. In this review, we will present key evidence in both the direct and indirect pathways, suggest clinical applications of the current literature, and recommend directions for future research. PMID:22119171

  6. An improved recommendation algorithm via weakening indirect linkage effect

    Science.gov (United States)

    Chen, Guang; Qiu, Tian; Shen, Xiao-Quan

    2015-07-01

    We propose an indirect-link-weakened mass diffusion method (IMD), by considering the indirect linkage and the source object heterogeneity effect in the mass diffusion (MD) recommendation method. Experimental results on the MovieLens, Netflix, and RYM datasets show that, the IMD method greatly improves both the recommendation accuracy and diversity, compared with a heterogeneity-weakened MD method (HMD), which only considers the source object heterogeneity. Moreover, the recommendation accuracy of the cold objects is also better elevated in the IMD than the HMD method. It suggests that eliminating the redundancy induced by the indirect linkages could have a prominent effect on the recommendation efficiency in the MD method. Project supported by the National Natural Science Foundation of China (Grant No. 11175079) and the Young Scientist Training Project of Jiangxi Province, China (Grant No. 20133BCB23017).

  7. The Indirect Costs of Financial Distress in Indonesia

    Directory of Open Access Journals (Sweden)

    Wijantini Wijantini

    2007-06-01

    Full Text Available This paper presents quantitative estimates of the indirect cost of financial distress and its determinants. In order to measure the cost, this study estimates the annualized changes in industry-adjusted operation profit and sales from a year before the onset of distress to the resolution year. Using those approaches, the median of indirect financial distress cost is estimated between three and 11 percent annually. To the extent that the direct cost of financial distress reduces reported operating income, the estimated costs are overstated. The simple regressions analysis suggest that the indirect cost of financial distress significantly increases with size, leverage, number of creditors, and poor industry performance, but is not related to degree of bank loan reliance. The findings provide a weak support for the financial distress theory which suggests that conflicts of interest render the costs of financial distress.

  8. Indirect control of flexible demand for power system applications

    DEFF Research Database (Denmark)

    Sossan, Fabrizio

    This thesis addresses the topic of control of flexible demand to provide support to the operation of the electric power system. We focus on the indirect control approach, a framework that enables demand response by means of a consumption incentive signal. Initially, the concept of flexibility...... a shift in the consumption according to an indirect control signal. We present from simple control algorithms with a few requirements up to model predictive control strategies. The performance of the indirect control algorithms are compared by means of hardware-in-the-loop simulations using Power...... and storage in the operation of the future power system, we develop a model predictive control strategy for a smart building with the objective of supplying iii space heating and providing regulating power to the grid according to a dynamic electricity price. We named this application energy replacement...

  9. Shear bond strength of indirect composite material to monolithic zirconia.

    Science.gov (United States)

    Sari, Fatih; Secilmis, Asli; Simsek, Irfan; Ozsevik, Semih

    2016-08-01

    This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). Bond strength was significantly lower in untreated specimens than in sandblasted specimens (Pcomposite material and monolithic zirconia.

  10. Stability Concerns for Indirect Consumer Control in Smart Grids

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Andersen, Palle; Wisniewski, Rafal

    2013-01-01

    by an external third party, and indirect consumer control through incentives and price signals. In this work we present a simple formulation of indirect control, where the behavior of each consumer, is governed by local optimization of energy consumption. The local optimization accounts for both cost of energy...... and distribution losses, as well as any discomfort incurred by consumers from any shift in energy consumption. Our work will illustrate that in the simplest formulation of indirect control, the stability is greatly affected of both the behavior of consumers, and the number of consumers to include. We will show how......Demand side management will be an important tool for maintaining a balanced electrical grid in the future, when the penetration of volatile resources, such as wind and solar energy increases. Recent research focuses on two different management approaches, namely direct consumer control...

  11. Estimating direct and indirect costs of premenstrual syndrome.

    Science.gov (United States)

    Borenstein, Jeff; Chiou, Chiun-Fang; Dean, Bonnie; Wong, John; Wade, Sally

    2005-01-01

    To quantify the economic impact of premenstrual syndrome (PMS) on the employer. Data were collected from 374 women aged 18-45 with regular menses. Direct costs were quantified using administrative claims of these patients and the Medicare Fee Schedule. Indirect costs were quantified by both self-reported days of work missed and lost productivity at work. Regression analyses were used to develop a model to project PMS-related direct and indirect costs. A total of 29.6% (n = 111) of the participants were diagnosed with PMS. A PMS diagnosis was associated with an average annual increase of $59 in direct costs (P increase in direct medical costs and a large increase in indirect costs.

  12. Direct and indirect pathways for choosing objects and actions.

    Science.gov (United States)

    Hikosaka, Okihide; Kim, Hyoung F; Amita, Hidetoshi; Yasuda, Masaharu; Isoda, Masaki; Tachibana, Yoshihisa; Yoshida, Atsushi

    2018-02-23

    A prominent target of the basal ganglia is the superior colliculus (SC) which controls gaze orientation (saccadic eye movement in primates) to an important object. This 'object choice' is crucial for choosing an action on the object. SC is innervated by the substantia nigra pars reticulata (SNr) which is controlled mainly by the caudate nucleus (CD). This CD-SNr-SC circuit is sensitive to the values of individual objects and facilitates saccades to good objects. The object values are processed differently in two parallel circuits: flexibly by the caudate head (CDh) and stably by the caudate tail (CDt). To choose good objects, we need to reject bad objects. In fact, these contrasting functions are accomplished by the circuit originating from CDt: The direct pathway focuses on good objects and facilitates saccades to them; the indirect pathway focuses on bad objects and suppresses saccades to them. Inactivation of CDt deteriorated the object choice, because saccades to bad objects were no longer suppressed. This suggests that the indirect pathway is important for object choice. However, the direct and indirect pathways for 'object choice', which aim at the same action (i.e., saccade), may not work for 'action choice'. One possibility is that circuits controlling different actions are connected through the indirect pathway. Additional connections of the indirect pathway with brain areas outside the basal ganglia may also provide a wider range of behavioral choice. In conclusion, basal ganglia circuits are composed of the basic direct/indirect pathways and additional connections and thus have acquired multiple functions. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  13. INDIRECT TAXATION TRENDS IN THE EUROPEAN UNION MEMBER STATES

    Directory of Open Access Journals (Sweden)

    MARIUS CRISTIAN MILOŞ

    2014-12-01

    Full Text Available The objective of this paper is to outline the recent dynamics of the indirect taxation in the European Union member states, with a special focus on the Romanian case. We could notice that indirect taxation continues to play an important role for all the member states, in their attempt to recover from the global economic crisis. Morover, we have presented some of the recent changes in the legislative frameworks, which happened with a rather rapid pace, and contributed to a rather challenging business climate.

  14. Neutron-capture cross sections from indirect measurements

    Directory of Open Access Journals (Sweden)

    Scielzo N.D.

    2012-02-01

    Full Text Available Cross sections for compound-nuclear reactions reactions play an important role in models of astrophysical environments and simulations of the nuclear fuel cycle. Providing reliable cross section data remains a formidable task, and direct measurements have to be complemented by theoretical predictions and indirect methods. The surrogate nuclear reactions method provides an indirect approach for determining cross sections for reactions on unstable isotopes, which are difficult or impossible to measure otherwise. Current implementations of the method provide useful cross sections for (n,f reactions, but need to be improved upon for applications to capture reactions.

  15. Direct and indirect welfare chauvinism as party strategies

    DEFF Research Database (Denmark)

    Careja, Romana; Elmelund-Præstekær, Christian; Klitgaard, Michael Baggesen

    2016-01-01

    welfare chauvinism occurs as a result of legislative changes that explicitly exclude recipients from social protection or reduce the level thereof on the basis of ethnicity. Indirect welfare chauvinism is the result of policy measures that apply to both natives and immigrants, but which deliberately...... and deliberate policy-making strategies of the party. It shows that the distinction between direct and indirect chauvinism is a useful theoretical tool for understanding how the Danish People's Party can fulfill the expectations of both its electorate and its coalition partners, even if they point in different...

  16. Indirect Fluorescent Antibody Technique based Prevalence of Surra in Equines

    Directory of Open Access Journals (Sweden)

    Ahsan Nadeem, Asim Aslam*, Zafar Iqbal Chaudhary, Kamran Ashraf1, Khalid Saeed1, Nisar Ahmad1, Ishtiaq Ahmed and Habib ur Rehman2

    2011-04-01

    Full Text Available This project was carried out to find the prevalence of trypanosomiasis in equine in District Gujranwala by using indirect fluorescent antibody technique and thin smear method. Blood samples were collected from a total of 200 horses and donkeys of different ages and either sex. Duplicate thin blood smears were prepared from each sample and remaining blood samples were centrifuged to separate the serum. Smears from each animal were processed for giemsa staining and indirect fluorescent antibody test (IFAT. Giemsa stained smears revealed Trypanosome infection in 4/200 (2.0% samples and IFAT in 12/200 (6.0% animals.

  17. Direct and indirect two-photon processes in semiconductors

    International Nuclear Information System (INIS)

    Hassan, A.R.

    1986-07-01

    The expressions describing direct and indirect two-photon absorption in crystals are given. They are valid both near and far from the energy gap. A perturbative approach through two different band models is adopted. The effects of the non-parabolicity and the degeneracy of the energy bands are considered. The numerical results are compared with the other theories and with a recent experimental data in Zn and AgCl. It is shown that the dominant transition mechanisms are of the allowed-allowed type near and far from the gap for both direct and indirect processes. (author)

  18. Neutron-capture Cross Sections from Indirect Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Escher, J E; Burke, J T; Dietrich, F S; Ressler, J J; Scielzo, N D; Thompson, I J

    2011-10-18

    Cross sections for compound-nuclear reactions play an important role in models of astrophysical environments and simulations of the nuclear fuel cycle. Providing reliable cross section data remains a formidable task, and direct measurements have to be complemented by theoretical predictions and indirect methods. The surrogate nuclear reactions method provides an indirect approach for determining cross sections for reactions on unstable isotopes, which are difficult or impossible to measure otherwise. Current implementations of the method provide useful cross sections for (n,f) reactions, but need to be improved upon for applications to capture reactions.

  19. Indirect search for neutralino dark matter with high energy neutrinos

    International Nuclear Information System (INIS)

    Barger, V.; Halzen, Francis; Hooper, Dan; Kao, Chung

    2002-01-01

    We investigate the prospects of indirect searches for supersymmetric neutralino dark matter. Relic neutralinos gravitationally accumulate in the Sun and their annihilations produce high energy neutrinos. Muon neutrinos of this origin can be seen in large detectors such as AMANDA, IceCube, and ANTARES. We evaluate the relic density and the detection rate in several models--the minimal supersymmetric model, minimal supergravity, and supergravity with nonuniversal Higgs boson masses at the grand unification scale. We make realistic estimates for the indirect detection rates including effects of the muon detection threshold, quark hadronization, and solar absorption. We find good prospects for detection of neutralinos with mass above 200 GeV

  20. Water augmented indirectly-fired gas turbine systems and method

    Science.gov (United States)

    Bechtel, Thomas F.; Parsons, Jr., Edward J.

    1992-01-01

    An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

  1. Testing indirect effect of consumer attitudes toward a product

    DEFF Research Database (Denmark)

    Hrubá, Renata; Sudzina, Frantisek

    2016-01-01

    a questionnaire in 2010-2011. The model is estimated using probit analysis to predict relationship between producer and consumer in decision-making when buying a new type of cheese and to examine consumer attitudes toward food origins and nutrient food security. It can be concluded that the indirect effect (e...... and on the indirect and direct effects of the perception of information through information behavior and the use of the model ordered. It is proposed that consumer levels of product familiarity of attributes affects behavior. Consumer attitudes towards agri-food products and behaviour were analyzed through...

  2. Fistule carotido-caverneuse indirecte post traumatique: diagnostic ...

    African Journals Online (AJOL)

    The indirect carotido-cavernous fistula is an abnormal communication between multiple arterioles coming from dural or meningeal branches of the external carotid artery and/or of the internal carotid artery and the cavernous sinus. Its definitive diagnosis relies on carotid angiography showing the fistula. This imaging ...

  3. Effects of Direct and Indirect Instructional Strategies on Students ...

    African Journals Online (AJOL)

    First Lady

    2012-10-27

    Oct 27, 2012 ... Counseling, University of Port Harcourt, Rivers State. Phone: +234(0) ... Mathematics using Direct Instructional strategy, while Group B students were taught using ... strategy; significant difference existed between direct and indirect instruction ..... is to ensure individual student's mastery of the subject matter.

  4. Determination of cyanide by a highly sensitive indirect spectrophotometric method.

    Science.gov (United States)

    Blanco, M; Maspoch, S

    1984-01-01

    Complexation of Pd(2+) with cyanide inhibits the extraction of the palladium complex of 5-phenylazo-8-aminoquinoline. This effect is used for the indirect spectrophotometric determination of cyanide at the mug level. Cyanide in industrial waste water and in sea-water is determined after distillation as HCN from the sample and collection in sodium hydroxide solution.

  5. A comparison of microhardness of indirect composite restorative materials

    DEFF Research Database (Denmark)

    Miranda, Carolina Baptista; Pagani, Clóvis; Bottino, Marco Cícero

    2003-01-01

    The purpose of this study was to compare the microhardness of four indirect composite resins. Forty cylindrical samples were prepared according to the manufacturer’s recommendations using a Teflon mold. Ten specimens were produced from each tested material, constituting four groups (n=10) as foll...... esthetics and adequate mechanical properties may be considered as substitutes of natural teeth....

  6. Direct versus indirect detection of supersymmetric dark matter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This document gathers the slides that were presented during the workshop 'direct versus indirect detection of supersymmetric dark matter'(about 30 contributions). This workshop intended to bring together people from the particle theory community, astrophysicists and cosmologists, as well as experimentalists involved in the detection of dark matter. The aim is to generate a discussion about current and future strategies for detection of SUSY dark matter (with focus, but not exclusively, on neutralinos). Complementarities between accelerator, direct and indirect searches as well as a comparison between the uncertainties in direct and indirect searches of dark matter, are supposed to be discussed. Among the issues which will be addressed are: -) the crucial questions related to the structure of galaxies (local dark matter density, clumping, anomalous velocity distributions, etc.) ; -) the possibilities offered by the present and future experimental facilities for direct and indirect (photon, neutrino) searches; -) the potential for the discovery of SUSY at LHC and beyond; and -) the parameterization of the SUSY breaking models beyond the minimal versions.

  7. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    An indirect matrix converter is an alternative "all-semiconductor" energy processor proposed recently for converting an ac source with fixed magnitude and frequency to a variable voltage and frequency supply that can meet the requirements of a particular industry application. In principle...

  8. Biological production of alcohols from coal through indirect liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Barik, S; Prieto, S; Harrison, S B; Clausen, E C; Gaddy, J L

    1988-08-01

    The purpose of this project is to demonstrate the feasibility of producing liquid fuels from the components of synthesis gas through biological indirect liquefaction. The results of pure culture and natural source screening studies aimed at finding organisms capable of carrying out the conversions are presented and discussed. 17 refs., 2 figs., 8 tabs.

  9. Silent, indirect strategic processes in small and medium sized enterprises

    DEFF Research Database (Denmark)

    Larsen, Mette Vinther; Madsen, Charlotte Øland; Rasmussen, Jørgen Gulddahl

    Based on empirical data we in this paper explore day-to-day strategising with an emphasis on phronesis. This way we shed some light on the nearly silent, quiet, indirect strategic change processes as they are practiced and reflected upon by leaders in small companies in their daily practice...

  10. Direct versus indirect detection of supersymmetric dark matter

    International Nuclear Information System (INIS)

    2003-01-01

    This document gathers the slides that were presented during the workshop 'direct versus indirect detection of supersymmetric dark matter'(about 30 contributions). This workshop intended to bring together people from the particle theory community, astrophysicists and cosmologists, as well as experimentalists involved in the detection of dark matter. The aim is to generate a discussion about current and future strategies for detection of SUSY dark matter (with focus, but not exclusively, on neutralinos). Complementarities between accelerator, direct and indirect searches as well as a comparison between the uncertainties in direct and indirect searches of dark matter, are supposed to be discussed. Among the issues which will be addressed are: -) the crucial questions related to the structure of galaxies (local dark matter density, clumping, anomalous velocity distributions, etc.) ; -) the possibilities offered by the present and future experimental facilities for direct and indirect (photon, neutrino) searches; -) the potential for the discovery of SUSY at LHC and beyond; and -) the parameterization of the SUSY breaking models beyond the minimal versions

  11. Current indirect fitness and future direct fitness are not incompatible.

    Science.gov (United States)

    Brahma, Anindita; Mandal, Souvik; Gadagkar, Raghavendra

    2018-02-01

    In primitively eusocial insects, many individuals function as workers despite being capable of independent reproduction. Such altruistic behaviour is usually explained by the argument that workers gain indirect fitness by helping close genetic relatives. The focus on indirect fitness has left open the question of whether workers are also capable of getting direct fitness in the future in spite of working towards indirect fitness in the present. To investigate this question, we recorded behavioural profiles of all wasps on six naturally occurring nests of Ropalidia marginata , and then isolated all wasps in individual plastic boxes, giving them an opportunity to initiate nests and lay eggs. We found that 41% of the wasps successfully did so. Compared to those that failed to initiate nests, those that did were significantly younger, had significantly higher frequency of self-feeding behaviour on their parent nests but were not different in the levels of work performed in the parent nests. Thus ageing and poor feeding, rather than working for their colonies, constrain individuals for future independent reproduction. Hence, future direct fitness and present work towards gaining indirect fitness are not incompatible, making it easier for worker behaviour to be selected by kin selection or multilevel selection. © 2018 The Author(s).

  12. Strong impacts on aerosol indirect effects from historical oxidant changes

    Science.gov (United States)

    Hafsahl Karset, Inger Helene; Koren Berntsen, Terje; Storelvmo, Trude; Alterskjær, Kari; Grini, Alf; Olivié, Dirk; Kirkevåg, Alf; Seland, Øyvind; Iversen, Trond; Schulz, Michael

    2018-06-01

    Uncertainties in effective radiative forcings through aerosol-cloud interactions (ERFaci, also called aerosol indirect effects) contribute strongly to the uncertainty in the total preindustrial-to-present-day anthropogenic forcing. Some forcing estimates of the total aerosol indirect effect are so negative that they even offset the greenhouse gas forcing. This study highlights the role of oxidants in modeling of preindustrial-to-present-day aerosol indirect effects. We argue that the aerosol precursor gases should be exposed to oxidants of its era to get a more correct representation of secondary aerosol formation. Our model simulations show that the total aerosol indirect effect changes from -1.32 to -1.07 W m-2 when the precursor gases in the preindustrial simulation are exposed to preindustrial instead of present-day oxidants. This happens because of a brightening of the clouds in the preindustrial simulation, mainly due to large changes in the nitrate radical (NO3). The weaker oxidative power of the preindustrial atmosphere extends the lifetime of the precursor gases, enabling them to be transported higher up in the atmosphere and towards more remote areas where the susceptibility of the cloud albedo to aerosol changes is high. The oxidation changes also shift the importance of different chemical reactions and produce more condensate, thus increasing the size of the aerosols and making it easier for them to activate as cloud condensation nuclei.

  13. Strong impacts on aerosol indirect effects from historical oxidant changes

    Directory of Open Access Journals (Sweden)

    I. H. H. Karset

    2018-06-01

    Full Text Available Uncertainties in effective radiative forcings through aerosol–cloud interactions (ERFaci, also called aerosol indirect effects contribute strongly to the uncertainty in the total preindustrial-to-present-day anthropogenic forcing. Some forcing estimates of the total aerosol indirect effect are so negative that they even offset the greenhouse gas forcing. This study highlights the role of oxidants in modeling of preindustrial-to-present-day aerosol indirect effects. We argue that the aerosol precursor gases should be exposed to oxidants of its era to get a more correct representation of secondary aerosol formation. Our model simulations show that the total aerosol indirect effect changes from −1.32 to −1.07 W m−2 when the precursor gases in the preindustrial simulation are exposed to preindustrial instead of present-day oxidants. This happens because of a brightening of the clouds in the preindustrial simulation, mainly due to large changes in the nitrate radical (NO3. The weaker oxidative power of the preindustrial atmosphere extends the lifetime of the precursor gases, enabling them to be transported higher up in the atmosphere and towards more remote areas where the susceptibility of the cloud albedo to aerosol changes is high. The oxidation changes also shift the importance of different chemical reactions and produce more condensate, thus increasing the size of the aerosols and making it easier for them to activate as cloud condensation nuclei.

  14. Estimating forest canopy bulk density using six indirect methods

    Science.gov (United States)

    Robert E. Keane; Elizabeth D. Reinhardt; Joe Scott; Kathy Gray; James Reardon

    2005-01-01

    Canopy bulk density (CBD) is an important crown characteristic needed to predict crown fire spread, yet it is difficult to measure in the field. Presented here is a comprehensive research effort to evaluate six indirect sampling techniques for estimating CBD. As reference data, detailed crown fuel biomass measurements were taken on each tree within fixed-area plots...

  15. Social Dilemmas and Indirect Reciprocity: A systematic review

    Directory of Open Access Journals (Sweden)

    Cristian Acosta

    2014-08-01

    Full Text Available Indirect reciprocity is an evolutionary theory of altruism and cooperation in social dilemmas. Its explanation of cooperation incorporates information on the reputation people hold of other people regarding whether they are cooperative or not. This study systematically reviewed the current empirical literature on indirect reciprocity in social dilemma situations. The following databases were consulted: ScienceDirect, EBSCO, and OVID, using has key words "indirect reciprocity" AND "dilemma" OR "cooperation" OR "charity". Twenty-three articles were selected which met the inclusion criteria (papers written in English and studies whose methodology was based on experimental games and the theories, objectives, the main types of samples used, and main results were analyzed. The results show that the games used were the indirect reciprocity and public goods games, which may vary according to the objectives. It was found that reputation is a key variable that helps to promote cooperation. In turn, information on previous cooperation helps to build reputation, which is subsequently involved in the decision to cooperate with others. Finally, we highlight the need for more experimental studies that incorporate other explanatory variables and evaluate them in new contexts.

  16. Vocabulary Acquisition through Direct and Indirect Learning Strategies

    Science.gov (United States)

    Naeimi, Maki; Foo, Thomas Chow Voon

    2015-01-01

    Vocabulary learning has long been considered as one of the essential components for developing language learning. However, language learners are required to not just concern about memorizing definitions but also integrating vocabulary meaning into their present knowledge. Many strategies such as direct or indirect ones may be integrated to enhance…

  17. 48 CFR 52.216-15 - Predetermined Indirect Cost Rates.

    Science.gov (United States)

    2010-10-01

    .... (c) Allowability of costs and acceptability of cost allocation methods shall be determined in...) the period for which the rates apply, and (4) the specific items treated as direct costs or any changes in the items previously agreed to be direct costs. The indirect cost rate agreement shall not...

  18. Indirect environmental effects of nuclear war affecting health

    International Nuclear Information System (INIS)

    Leaf, A.

    1984-01-01

    The indirect effects of a nuclear war that will affect the health of survivors are considered to include consequences to: (a) the economies of nations, (b) food and nutrition, (c) water supplies, (d) the climate and the ecosphere, and (e) sanitation and public health; and they include long-term radiation effects

  19. Effects of Direct and Indirect Instructional Strategies on Students ...

    African Journals Online (AJOL)

    This is a quasi experimental research designed to determine the effects of Direct and Indirect instructional strategies on Mathematics achievement among junior secondary school students. The population consisted of students in a Public Secondary School in Owerri, Imo State. A sample of 102 students from two (2) intact ...

  20. Estimating two indirect logging costs caused by accelerated erosion.

    Science.gov (United States)

    Glen O. Klock

    1976-01-01

    In forest areas where high soil erosion potential exists, a comparative yarding cost estimate, including the indirect costs determined by methods proposed here, shows that the total cost of using "advanced" logging methods may be less than that of "traditional" systems.

  1. 48 CFR 49.303-4 - Adjustment of indirect costs.

    Science.gov (United States)

    2010-10-01

    ... costs. 49.303-4 Section 49.303-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TERMINATION OF CONTRACTS Additional Principles for Cost-Reimbursement Contracts... compute indirect costs for other contracts performed during the applicable accounting period. [48 FR 42447...

  2. 23 CFR 140.907 - Overhead and indirect construction costs.

    Science.gov (United States)

    2010-04-01

    ... accounting principles; (2) The costs included in the distribution are limited to costs actually incurred by...), part 31, Contract Cost Principles and Procedures, relating to contracts with commercial organizations... 23 Highways 1 2010-04-01 2010-04-01 false Overhead and indirect construction costs. 140.907...

  3. Indirect self-destructiveness in individuals with schizophrenia

    Directory of Open Access Journals (Sweden)

    Konstantinos Tsirigotis

    2017-06-01

    Full Text Available Objective: To explore the indirect self-destructiveness syndrome in patients with schizophrenia. Methods: Two hundred individuals with paranoid schizophrenia (117 men and 83 women, mean age 37.15 years, all in remission, were examined using the Polish version of the Chronic Self-Destructiveness Scale. Two hundred well-matched healthy individuals served as a control group. Results: The intensity of indirect self-destructiveness was greater in the schizophrenia group than in controls. The intensity of each manifestation was as follows (in decreasing order: helplessness and passiveness in the face of difficulties (A5, personal and social neglects (A3, lack of planfulness (A4, poor health maintenance (A2, transgression and risk (A1. Conclusion: Patients with schizophrenia displayed more behaviors that were indirectly self-destructive than healthy controls; they scored better than healthy controls only on caring for their own health. The patients showed the lowest intensity of behaviors connected with the active form of indirect self-destructiveness, and the highest intensity of behaviors connected with the passive form. These findings may enable delivery of more effective forms of pharmacological and psychosocial help to patients with schizophrenia.

  4. Indirect calorimetry: assessing animal response to heat and cold stress

    NARCIS (Netherlands)

    Gaughan, J.B.; Heetkamp, M.J.W.; Hendriks, P.

    2015-01-01

    Calorimetric thermal stress studies where indirect calorimetry is used as a tool to estimate energy expenditure have been undertaken since this technique was developed. Some examples of these studies are presented in this chapter. The measurement of gas exchange by means of an open-circuit

  5. STEM Faculty and Indirect Costs: What Administrators Need to Know

    Science.gov (United States)

    Gossman, Susan

    2016-01-01

    The focus of this single site, qualitative case study was on public research university STEM (science, technology, engineering and mathematics) faculty and their perspectives on, and behavior towards, indirect cost recovery. The explanatory scheme was derived from anthropological theory and incorporated organizational culture, resource dependency…

  6. U.S. DOE indirect coal liquefaction program: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Shen, J.; Schmetz, E.; Winslow, J.; Tischer, R. [Dept. of Energy, Germantown, MD (United States); Srivastava, R.

    1997-12-31

    Coal is the most abundant domestic energy resource in the United States. The Fossil Energy Organization within the US Department of Energy (DOE) has been supporting a coal liquefaction program to develop improved technologies to convert coal to clean and cost-effective liquid fuels to complement the dwindling supply of domestic petroleum crude. The goal of this program is to produce coal liquids that are competitive with crude at $20 to $25 per barrel. Indirect and direct liquefaction routes are the two technologies being pursued under the DOE coal liquefaction program. This paper will give an overview of the DOE indirect liquefaction program. More detailed discussions will be given to the F-T diesel and DME fuels which have shown great promises as clean burning alternative diesel fuels. The authors also will briefly discuss the economics of indirect liquefaction and the hurdles and opportunities for the early commercial deployment of these technologies. Discussions will be preceded by two brief reviews on the liquid versus gas phase reactors and the natural gas versus coal based indirect liquefaction.

  7. Contribution of indirect obstetric deaths to maternal mortality at ...

    African Journals Online (AJOL)

    Introduction: Maternal death is unacceptably high in this center like in most centers in the developing world. Objective: To determine the maternal mortality ratio and the contribution of the direct and indirect obstetric complications to maternal deaths. Method: A retrospective review of all maternal deaths at Nnamdi Azikiwe ...

  8. In vitro and in vivo Comparison of Orthodontic Indirect Bonding ...

    African Journals Online (AJOL)

    2018-05-22

    May 22, 2018 ... 2018 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer ‑ Medknow. Objective: The aim of this study was to evaluate in vitro shear bond strength ... with indirect bonding resins that were either chemically or light-cured. ...... strength of composite, glass ionomer, and acidic primer adhesive.

  9. Special considerations regarding indirect expropriation in international economic law

    Directory of Open Access Journals (Sweden)

    Laura-Cristiana Spătaru-Negură

    2017-12-01

    Full Text Available The right to property is a human right that has to be respected so that if the property of a natural or legal person is taken over, the respective person has to be compensated. The right of a state to control the economic business is one of the rights sustained and exercised by the states on a constant basis. This reflects the inherent sovereignty of a state to control its people, incidents and objects found on its territory. Between these rights, the situation of indirect expropriation appears which has been described in the doctrine as being very abstract and rigid, big lacunae existing. The sense of the indirect expropriation and of the international investors’ protection against the indirect expropriation is very ambiguous. Using different methods specific to scientific analyse of the legal phenomenon (e.g. the logical method, the comparative method, the historical method and the quantitative methods, we consider that through this paper we can reach certain results that could be interesting for any legal practitioner or theoretician, this paper intending to present the most relevant cases that could amount to indirect expropriation.

  10. 49 CFR 30.9 - Citizenship: Direct or indirect control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Citizenship: Direct or indirect control. 30.9 Section 30.9 Transportation Office of the Secretary of Transportation DENIAL OF PUBLIC WORKS CONTRACTS TO... title to 50 percent or more of the stock of the contractor or subcontractor is held subject to trust or...

  11. Exhaled breath profiling using broadband quantum cascade laser-based spectroscopy in healthy children and children with asthma and cystic fibrosis.

    Science.gov (United States)

    van Mastrigt, E; Reyes-Reyes, A; Brand, K; Bhattacharya, N; Urbach, H P; Stubbs, A P; de Jongste, J C; Pijnenburg, M W

    2016-04-08

    Exhaled breath analysis is a potential non-invasive tool for diagnosing and monitoring airway diseases. Gas chromatography-mass spectrometry and electrochemical sensor arrays are the main techniques to detect volatile organic compounds (VOC) in exhaled breath. We developed a broadband quantum cascade laser spectroscopy technique for VOC detection and identification. The objective of this study was to assess the repeatability of exhaled breath profiling with broadband quantum cascade laser-based spectroscopy and to explore the clinical applicability by comparing exhaled breath samples from healthy children with those from children with asthma or cystic fibrosis (CF). Healthy children and children with stable asthma or stable CF, aged 6-18 years, were included. Two to four exhaled breath samples were collected in Tedlar bags and analyzed by quantum cascade laser spectroscopy to detect VOCs with an absorption profile in the wavenumber region between 832 and 1262.55 cm(-1). We included 35 healthy children, 39 children with asthma and 15 with CF. Exhaled breath VOC profiles showed poor repeatability (Spearman's rho  =  0.36 to 0.46) and agreement of the complete profiles. However, we were able to discriminate healthy children from children with stable asthma or stable CF and identified VOCs that were responsible for this discrimination. Broadband quantum cascade laser-based spectroscopy detected differences in VOC profiles in exhaled breath samples between healthy children and children with asthma or CF. The combination of a relatively easy and fast method and the possibility of molecule identification makes broadband quantum cascade laser-based spectroscopy attractive to investigate the diagnostic and prognostic potential of volatiles in exhaled breath.

  12. Indirect pulp capping in primary molar using glass ionomer cements

    Directory of Open Access Journals (Sweden)

    Murtia Metalita

    2014-12-01

    Full Text Available Background: Indirect pulp capping in primary teeth, however, is more rarely conducted than permanent teeth, since it thought to have low impact and most suggestion is for taking caries lesion aggressively on primary teeth. Purpose: The study was aimed to evaluate the subjective complaint, clinical symptom, and radiographic appearance of indirect pulp capping treatment using glass ionomers cements in primary molar. Methods: Sixteen children in range of age 6 to 8 years old, who visited Clinic of Pediatric Dentistry Universitas Airlangga Dental Hospital, Surabaya Indonesia, were the subject of study. They had one occlusal dental caries on one side of maxillary or mandibular primary molar with the diagnose of pulpitis reversible. The experimental group, had indirect pulp capping treatment with glass ionomer cements (GC Fuji VII®, while the control group, had indirect pulp capping treatment with calcium hydroxide (Metapaste. Each group was filled with GC Fuji IX® as permanent restoration. After one week, one month, and three months later, the observations were made on subjective complaint, clinical symptom, and radiographic appearance. Results: The results showed no subjective complaint such as pain or problem on mastication; no negative clinical symptoms such as pain on palpation, gingivitis or periodontitis, and abnormal tooth mobility; no negative radiographic appearance such as pathological apical radioluscency, internal or external resorbtion, and change of ligament periodontal widthafter the treatment. Conclusion: The study suggested that indirect pulp capping treatment using glass ionomer cement materials on primary teeth might be considered to be the treatment choice.Latar belakang: Indirect pulp capping pada gigi sulung lebih jarang dilakukan dibandingkan gigi permanen, karena dianggap memiliki dampak yang rendah dan sebagian besar menyarankan untuk mengambil lesi karies secara agresif pada gigi sulung. Tujuan: Penelitian ini bertujuan

  13. Self-sustained pulsation in the oxide-confined vertical-cavity surface-emitting lasers based on submonolayer InGaAs quantum dots

    International Nuclear Information System (INIS)

    Kuzmenkov, A. G.; Ustinov, V. M.; Sokolovskii, G. S.; Maleev, N. A.; Blokhin, S. A.; Deryagin, A. G.; Chumak, S. V.; Shulenkov, A. S.; Mikhrin, S. S.; Kovsh, A. R.; McRobbie, A. D.; Sibbett, W.; Cataluna, M. A.; Rafailov, E. U.

    2007-01-01

    The authors report the observation of strong self-pulsations in molecular-beam epitaxy-grown oxide-confined vertical-cavity surface-emitting lasers based on submonolayer InGaAs quantum dots. At continuous-wave operation, self-pulsations with pulse durations of 100-300 ps and repetition rates of 0.2-0.6 GHz were measured. The average optical power of the pulsations was 0.5-1.0 mW at the laser continuous-wave current values of 1.5-2.5 mA

  14. Towards large-scale production of solution-processed organic tandem modules based on ternary composites: Design of the intermediate layer, device optimization and laser based module processing

    DEFF Research Database (Denmark)

    Li, Ning; Kubis, Peter; Forberich, Karen

    2014-01-01

    on commercially available materials, which enhances the absorption of poly(3-hexylthiophene) (P3HT) and as a result increase the PCE of the P3HT-based large-scale OPV devices; 3. laser-based module processing, which provides an excellent processing resolution and as a result can bring the power conversion...... efficiency (PCE) of mass-produced organic photovoltaic (OPV) devices close to the highest PCE values achieved for lab-scale solar cells through a significant increase in the geometrical fill factor. We believe that the combination of the above mentioned concepts provides a clear roadmap to push OPV towards...

  15. A Tunable CW Orange Laser Based on a Cascaded MgO:PPLN Single-Pass Sum-Frequency Generation Module

    OpenAIRE

    Dismas K. Choge; Huai-Xi Chen; Bao-Lu Tian; Yi-Bin Xu; Guang-Wei Li; Wan-Guo Liang

    2018-01-01

    We report an all-solid-state continuous wave (CW) tunable orange laser based on cascaded single-pass sum-frequency generation with fundamental wavelengths at 1545.7 and 975.2 nm using two quasi-phase-matched (QPM) MgO-doped periodically poled lithium niobate (MgO:PPLN) crystals. Up to 10 mW of orange laser is generated in the cascaded module corresponding to a 10.4%/W nonlinear conversion efficiency. The orange output showed a temperature tuning rate of ~0.05 nm/°C, and the beam quality (M2) ...

  16. Diode-pumped passively Q-switched Nd:GdTaO4 laser based on tungsten disulfide nanosheets saturable absorber at 1066 nm

    Science.gov (United States)

    Li, M. X.; Jin, G. Y.; Li, Y.

    2018-05-01

    In this paper, we investigated the passively Q-switched Nd:GdTaO4 laser based on tungsten disulfide (WS2) saturable absorber (SA). The preparation method of WS2 SA was to attach the WS2-alcohol dispersion onto the quartz substrates. The diode-pumped passively Q-switched Nd:GdTaO4 laser operated at a central wavelength of 1066 nm. The stable pulse output could be obtained at the single pulse width of 560 ns. In a word, WS2 seems to be a suitable saturable absorber for solid state lasers.

  17. Groupwise information sharing promotes ingroup favoritism in indirect reciprocity.

    Science.gov (United States)

    Nakamura, Mitsuhiro; Masuda, Naoki

    2012-11-05

    Indirect reciprocity is a mechanism for cooperation in social dilemma situations. In indirect reciprocity, an individual is motivated to help another to acquire a good reputation and receive help from others afterwards. Another aspect of human cooperation is ingroup favoritism, whereby individuals help members in their own group more often than those in other groups. Ingroup favoritism is a puzzle for the theory of cooperation because it is not easily evolutionarily stable. In the context of indirect reciprocity, ingroup favoritism has been shown to be a consequence of employing a double standard when assigning reputations to ingroup and outgroup members. An example of such a double standard is the situation in which helping an ingroup member is regarded as good, whereas the same action toward an outgroup member is regarded as bad. We analyze a computational model of indirect reciprocity in which information sharing is conducted groupwise. In our model, individuals play social dilemma games within and across groups, and the information about their reputations is shared within each group. We show that evolutionarily stable ingroup favoritism emerges even if all the players use the same reputation assignment rule regardless of group (i.e., a single standard). Two reputation assignment rules called simple standing and stern judging yield ingroup favoritism; under these rules, cooperation with (defection against) good individuals is regarded as good (bad) and defection against bad individuals is regarded as good. Stern judging induces much stronger ingroup favoritism than does simple standing. Simple standing and stern judging are evolutionarily stable against each other when groups employing different assignment rules compete and the number of groups is sufficiently large. In addition, we analytically show as a limiting case that homogeneous populations of reciprocators that use reputations are unstable when individuals independently infer reputations of individuals

  18. A diode laser-based velocimeter providing point measurements in unseeded flows using modulated filtered Rayleigh scattering (MFRS)

    Science.gov (United States)

    Jagodzinski, Jeremy James

    2007-12-01

    The development to date of a diode-laser based velocimeter providing point-velocity-measurements in unseeded flows using molecular Rayleigh scattering is discussed. The velocimeter is based on modulated filtered Rayleigh scattering (MFRS), a novel variation of filtered Rayleigh scattering (FRS), utilizing modulated absorption spectroscopy techniques to detect a strong absorption of a relatively weak Rayleigh scattered signal. A rubidium (Rb) vapor filter is used to provide the relatively strong absorption; alkali metal vapors have a high optical depth at modest vapor pressures, and their narrow linewidth is ideally suited for high-resolution velocimetry. Semiconductor diode lasers are used to generate the relatively weak Rayleigh scattered signal; due to their compact, rugged construction diode lasers are ideally suited for the environmental extremes encountered in many experiments. The MFRS technique utilizes the frequency-tuning capability of diode lasers to implement a homodyne detection scheme using lock-in amplifiers. The optical frequency of the diode-based laser system used to interrogate the flow is rapidly modulated about a reference frequency in the D2-line of Rb. The frequency modulation is imposed on the Rayleigh scattered light that is collected from the probe volume in the flow under investigation. The collected frequency modulating Rayleigh scattered light is transmitted through a Rb vapor filter before being detected. The detected modulated absorption signal is fed to two lock-in amplifers synchronized with the modulation frequency of the source laser. High levels of background rejection are attained since the lock-ins are both frequency and phase selective. The two lock-in amplifiers extract different Fourier components of the detected modulated absorption signal, which are ratioed to provide an intensity normalized frequency dependent signal from a single detector. A Doppler frequency shift in the collected Rayleigh scattered light due to a change

  19. Trait- and density-mediated indirect interactions initiated by an exotic invasive plant autogenic ecosystem engineer

    Science.gov (United States)

    Dean E. Pearson

    2010-01-01

    Indirect interactions are important for structuring ecological systems. However, research on indirect effects has been heavily biased toward top-down trophic interactions, and less is known about other indirect-interaction pathways. As autogenic ecosystem engineers, plants can serve as initiators of nontrophic indirect interactions that, like top-down pathways, can...

  20. Indirect evidence for decreased hypothalamic somatostatinergic tone in anorexia nervosa

    DEFF Research Database (Denmark)

    Støving, R K; Andersen, M; Flyvbjerg, A

    2002-01-01

    in the central feeding mechanism in anorexia nervosa (AN). Peripheral administration of pyridostigmine (PD) minimizes the release of hypothalamic SRIH. DESIGN: To study the influence of hypothalamic somatostatinergic inhibition on the exaggerated somatotroph responsiveness to GHRH in patients with severe AN, two...... indirectly to greater SRIH withdrawal and greater GHRH release in anorexia nervosa. Moreover, hypothalamic SRIH activity seems to be inversely related to cortisol levels, indirectly supporting the hypothesis that SRIH and CRH neuronal activity are inversely related in anorexia nervosa. Leptin, which...... is believed to act on hypothalamic feeding mechanisms, seems to be positively related to SRIH activity. Finally, the present data demonstrate that the potentiating effect of pyridostigmine in anorexia nervosa is related to body mass index and increases upon weight gain, suggesting that the low...

  1. Exploring untrained interpreters' use of direct versus indirect speech

    DEFF Research Database (Denmark)

    Dubslaff, Friedel; Martinsen, Bodil

    2005-01-01

    by personalizing the indefinite pronoun 'one' when relaying from doctor to patient. All other pronoun shifts occurred in connection with interactional problems caused almost exclusively by the interpreters' lack of knowledge about medical terminology - even though the terms used were in fact non-specialized ones....... The study also indicates that primary parties' shifts from direct to indirect address are closely related either to the form or to the content of the interpreter's prior utterance. Finally, it emerges that repeated one-language talk, triggered by the interpreter's problems with medical terminology, can......This study examines the interrelations between the use of direct vs. indirect speech by primary participants and by dialogue interpreters by focusing on pronoun shifts and their interactional functions. The data consist of four simulated interpreter-mediated medical interviews based on the same...

  2. Dehydration of sodium carbonate monohydrate with indirect microwave heating

    International Nuclear Information System (INIS)

    Seyrankaya, Abdullah; Ozalp, Baris

    2006-01-01

    In this study, dehydration of sodium carbonate monohydrate (Na 2 CO 3 .H 2 O) (SCM) in microwave (MW) field with silicon carbide (SiC) as an indirect heating medium was investigated. SCM samples containing up to 3% free moisture were placed in the microwave oven. The heating experiments showed that SCM is a poor microwave energy absorber for up to 6 min of irradiation at an 800 W of microwave power. The heat for SCM calcination is provided by SiC which absorbs microwave. The monohydrate is then converted to anhydrous sodium carbonate on the SiC plate by calcining, i.e. by removing the crystal water through heating of the monohydrate temperatures of over 120 deg. C. The calcination results in a solid phase recrystallization of the monohydrate into anhydrate. In the microwave irradiation process, dehydration of SCM in terms of indirect heating can be accelerated by increasing the microwave field power

  3. Evaluating aerosol indirect effect through marine stratocumulus clouds

    Energy Technology Data Exchange (ETDEWEB)

    Kogan, Z.N.; Kogan, Y.L.; Lilly, D.K. [Univ. of Oklahoma, Norman, OK (United States)

    1996-04-01

    During the last decade much attention has been focused on anthropogenic aerosols and their radiative influence on the global climate. Charlson et al. and Penner et al. have demonstrated that tropospheric aerosols and particularly anthropogenic sulfate aerosols may significantly contribute to the radiative forcing exerting a cooling influence on climate (-1 to -2 W/m{sup 2}) which is comparable in magnitude to greenhouse forcing, but opposite in sign. Aerosol particles affect the earth`s radiative budget either directly by scattering and absorption of solar radiation by themselves or indirectly by altering the cloud radiative properties through changes in cloud microstructure. Marine stratocumulus cloud layers and their possible cooling influence on the atmosphere as a result of pollution are of special interest because of their high reflectivity, durability, and large global cover. We present an estimate of thet aerosol indirect effect, or, forcing due to anthropogenic sulfate aerosols.

  4. Review of indirect detection of dark matter with neutrinos

    Science.gov (United States)

    Danninger, Matthias

    2017-09-01

    Dark Matter could be detected indirectly through the observation of neutrinos produced in dark matter self-annihilations or decays. Searches for such neutrino signals have resulted in stringent constraints on the dark matter self-annihilation cross section and the scattering cross section with matter. In recent years these searches have made significant progress in sensitivity through new search methodologies, new detection channels, and through the availability of rich datasets from neutrino telescopes and detectors, like IceCube, ANTARES, Super-Kamiokande, etc. We review recent experimental results and put them in context with respect to other direct and indirect dark matter searches. We also discuss prospects for discoveries at current and next generation neutrino detectors.

  5. Indirect and two fold measurements in quantum mechanics

    International Nuclear Information System (INIS)

    Fer, Francis

    1981-01-01

    Keeping strictly in the positivist, probabilistic and hilbertian frame of quantum mechanics, the author develops a criticism of the accepted theory of indirect and twofold measurements. He shows that this theory cannot logically derive from the usual axiomatics, namely from the so-called reduction-of-state axiom. He proposes a modified statement (already used sometimes) of this axiom, which leads to a reliable theory of indirect and twofold measurements. The results are particularly: a) that a measurement made on a sub-system does not modify the mathematical representation of the complementary system, nor its prior probability distributions; b) that measurement is nothing else than an information which enables to correct the probabilities of further measurements according to the classical rules of the calculus of probabilities [fr

  6. The Dominance of Indirect Taxes in Estonian State Budget

    Directory of Open Access Journals (Sweden)

    Olev Raju

    2013-01-01

    Full Text Available Recession has sharply erected the question of tax burden and the optimal proportion of different kinds of taxes among the incomes of the budget. Indirect taxes and consumption taxes, which proportion is different according to different methodologies, dominate in Estonian state budget. The buoyancy of a tax system based on taxes of that kind is especially weak during the recession. Difficulties concerning the incomes of budget have arisen the necessity for lifting taxes, which is possible as the tax burden is low now. But a sharp question of the optimal level of taxes is going to be raised. A formula for indirect tax optimum according to Ramsey taxes and Slutski decomposition has been proposed in the article.

  7. Kant’s concept of indirect duties and environmental ethics

    Directory of Open Access Journals (Sweden)

    Milene Consenso Tonetto

    2017-12-01

    Full Text Available The aim of this paper is to assess whether Kant’s moral theory is suitable to deal with our obligations to take care of nonhuman animals and the environment. Kant’s ethics distinguishes persons, that is, rational beings with unconditional values who are considered as ends in themselves, from things, which have only relative worth. In relation to nature as a whole and to nonrational beings, Kant argues that we have only indirect duties or duties with regard to them. According to some philosophers, Kant’s ethics has anthropocentric starting points which lead to speciesist conclusions. This paper will argue that indirect duties can be in accordance with nonhuman interests, such as the suffering of nonhuman animals, the preservation of species and ecosystems, and so on. Thus Kant’s moral philosophy may contribute to environmental ethics because it justifies at least animal welfare and environmental protections as constraints on unrestricted human action.

  8. Indirect Reciprocity with Optional Interactions and Private Information

    Directory of Open Access Journals (Sweden)

    Jason Olejarz

    2015-09-01

    Full Text Available We consider indirect reciprocity with optional interactions and private information. A game is offered between two players and accepted unless it is known that the other person is a defector. Whenever a defector manages to exploit a cooperator, his or her reputation is revealed to others in the population with some probability. Therefore, people have different private information about the reputation of others, which is a setting that is difficult to analyze in the theory of indirect reciprocity. Since a defector loses a fraction of his social ties each time he exploits a cooperator, he is less efficient at exploiting cooperators in subsequent rounds. We analytically calculate the critical benefit-to-cost ratio above which cooperation is successful in various settings. We demonstrate quantitative agreement with simulation results of a corresponding Wright–Fisher process with optional interactions and private information. We also deduce a simple necessary condition for the critical benefit-to-cost ratio.

  9. Utility loss and indirect costs after stroke in Sweden.

    Science.gov (United States)

    Lindgren, Peter; Glader, Eva-Lotta; Jönsson, Bengt

    2008-04-01

    Currently little data exist on the development of quality of life over time in patients suffering from stroke, in particular using instruments that can be adapted in economic studies. The purpose of the study was to assess the utility loss and indirect costs following a stroke in Sweden. A cross-sectional mail survey. In collaboration with the National Stroke registry (RIKS-STROKE), a questionnaire consisting of the EuroQol-5D and questions regarding the present working status and the status prior to the stroke was mailed to patients below 76 years of age at six participating centres. The questionnaire was mailed to 393 patients in total, divided into groups with 3, 6, 9 or 12 months having passed since the stroke. The EuroQol-5D scores were converted to utility scores using the UK social tariff. Indirect costs were valued according to the average salary+employer contributions. A total of 275 questionnaires (70%) were returned. Utility scores were similar over time: 0.65, 0.75, 0.63, and 0.67 at 3, 6, 9 and 12 months, respectively. Regression analyses revealed a tendency for lower utility scores among women, but no significant differences overall. Among patients in the working ages, a stroke caused 18.5 work weeks lost, corresponding to an indirect cost of 120,000 Swedish Kronor (SEK) (13,200euro, 95% confidence interval 82,541-160,050 SEK, 9080-17 605euro). Stroke causes a significant reduction in utility and causes high indirect costs. A substantial improvement was not noted over time, which is important to consider in economic models.

  10. NATIONAL SCIENCE FOUNDATION. Preliminary Observations on Indirect Costs for Research

    Science.gov (United States)

    2017-05-24

    involvement between NSF and the awardee in carrying out the activity supported by the award. 2Office of Management and Budget , Uniform Administrative...NSF’s Award Cash Management $ervice—NSF’s online approach to award payments and post-award financial processes—does not collect data about indirect...percent. 16NSF’s Award Cash Management $ervice implements the OMB-approved form for awardees to report financial data on their federal awards. The

  11. Direct and indirect effects of organizational justice on work ability.

    Science.gov (United States)

    Spanier, K; Radoschewski, F M; Gutenbrunner, C; Bethge, M

    2014-12-01

    Organizational justice (OJ), involving transparent workplace procedures and treating staff members with respect, has been of growing concern in recent epidemiological research as a determinant of health-related outcomes. To examine the factorial validity of the German version of Moorman's Organizational Justice Questionnaire (OJQ), to investigate the direct cross-sectional effect of OJ on self-rated work ability and to analyse if there is an additional indirect effect of OJ on work ability mediated by effort-reward imbalance. An analysis of cross-sectional data from the Second German Sociomedical Panel of Employees, involving white-collar workers employed at least half time. We performed confirmatory factor analyses to test the factorial validity of the OJQ and analysed the direct and indirect associations of OJ and self-rated work ability by path model analysis. Of the 1217 participants (47% female; mean age: 51) 36% had poor work ability. Factor analyses confirmed the two-factor structure of the German OJQ. Work ability was explained directly by OJ (β = 0.30) and effort-reward imbalance (β = -0.27). Additionally, we identified an indirect effect of OJ that was mediated by effort-reward imbalance (β = 0.14). The total effect of OJ on work ability was remarkably strong (β = 0.44). Associations remained unchanged after adjustment for socio-demographic parameters. This study showed the importance of considering additional indirect pathways when examining the impact of OJ on the work ability of employees. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Numerical simulation of a semi-indirect evaporative cooler

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R. Herrero [Departamento de Ingenieria Termica y de Fluidos, Universidad Politecnica de Cartagena, C/Dr. Fleming, s/n (Campus Muralla), 30202 Cartagena, Murcia (Spain)

    2009-11-15

    This paper presents the experimental study and numerical simulation of a semi-indirect evaporative cooler (SIEC), which acts as an energy recovery device in air conditioning systems. The numerical simulation was conducted by applying the CFD software FLUENT implementing a UDF to model evaporation/condensation. The numerical model was validated by comparing the simulation results with experimental data. Experimental data and numerical results agree for the lower relative humidity series but not for higher relative humidity values. (author)

  13. Ion irradiation and biomolecular radiation damage II. Indirect effect

    OpenAIRE

    Wang, Wei; Yu, Zengliang; Su, Wenhui

    2010-01-01

    It has been reported that damage of genome in a living cell by ionizing radiation is about one-third direct and two-thirds indirect. The former which has been introduced in our last paper, concerns direct energy deposition and ionizing reactions in the biomolecules; the latter results from radiation induced reactive species (mainly radicals) in the medium (mainly water) surrounding the biomolecules. In this review, a short description of ion implantation induced radical formation in water is ...

  14. Total, Direct, and Indirect Effects in Logit Models

    DEFF Research Database (Denmark)

    Karlson, Kristian Bernt; Holm, Anders; Breen, Richard

    It has long been believed that the decomposition of the total effect of one variable on another into direct and indirect effects, while feasible in linear models, is not possible in non-linear probability models such as the logit and probit. In this paper we present a new and simple method...... average partial effects, as defined by Wooldridge (2002). We present the method graphically and illustrate it using the National Educational Longitudinal Study of 1988...

  15. Proton-induced direct and indirect damage of plasmid DNA

    Czech Academy of Sciences Publication Activity Database

    Vyšín, Luděk; Pachnerová Brabcová, Kateřina; Štěpán, V.; Moretto-Capelle, P.; Bugler, B.; Legube, G.; Cafarelli, P.; Casta, R.; Champeaux, J. P.; Sence, M.; Vlk, M.; Wagner, Richard; Štursa, Jan; Zach, Václav; Incerti, S.; Juha, Libor; Davídková, Marie

    2015-01-01

    Roč. 54, č. 3 (2015), s. 343-352 ISSN 0301-634X R&D Projects: GA ČR GA13-28721S; GA MŠk LD12008; GA MŠk LM2011019 Institutional support: RVO:68378271 ; RVO:61389005 Keywords : proton radiation * DNA plasmid * direct and indirect effects * clustered damage * repair enzymes Subject RIV: BO - Biophysics Impact factor: 1.923, year: 2015

  16. “Other” indirect methods for nuclear astrophysics

    Directory of Open Access Journals (Sweden)

    Trache Livius

    2017-01-01

    Full Text Available In the house of Trojan Horse Method (THM, I will say a few words about “other” indirect methods we use in Nuclear Physics for Astrophysics. In particular those using Rare Ion Beams that can be used to evaluate radiative proton capture reactions. I add words about work done with the Professore we celebrate today. With a proposal, and some results with TECSA, for a simple method to produce and use isomeric beam of 26mAl.

  17. Cooperative Exploration for USAR Robots with Indirect Communication

    OpenAIRE

    Ziparo, V. A.; Kleiner, Alexander; Farinelli, A.; Marchetti, L.; Nardi, D.

    2007-01-01

    To coordinate a team of robots for exploration is a challenging problem, particularly in unstructured areas, as for example post-disaster scenarios where direct communication is severely constrained. Furthermore, conventional methods of SLAM, e.g. those performing data association based on visual features, are doomed to fail due to bad visibility caused by smoke and fire. We use indirect communication (based on RFIDs), to share knowledge and use a gradient-like local search to direct robots t...

  18. Separation of the mercury isotopes by the indirect photochemical method

    International Nuclear Information System (INIS)

    Botter nee Bergheaud, F.; Scaringella nee Desnoyer, M.; Wacongne, M.

    1976-01-01

    A method of photochemical separation of the mercury isotopes by the so-called indirect route in which a gas stream of oxygen and butadiene containing a mixture of mercury isotopes is passed through one or a number of vessels placed in series. The gas stream is irradiated by a lamp containing mercury which is depleted in one or a number of the isotopes and said isotopes are recovered in a trap placed downstream of the vessel or vessels

  19. A comparative investigation of seven indirect attitude measures.

    Science.gov (United States)

    Bar-Anan, Yoav; Nosek, Brian A

    2014-09-01

    We compared the psychometric qualities of seven indirect attitude measures across three attitude domains (race, politics, and self-esteem) with a large sample (N = 23,413). We compared the measures on internal consistency, sensitivity to known effects, relationships with indirect and direct measures of the same topic, the reliability and validity of single-category attitude measurement, their ability to detect meaningful variance among people with nonextreme attitudes, and their robustness to the exclusion of misbehaving or well-behaving participants. All seven indirect measures correlated with each other and with direct measures of the same topic. These relations were always weak for self-esteem, moderate for race, and strong for politics. This pattern suggests that some of the sources of variation in the reliability and predictive validity of the indirect measures is a function of the concepts rather than the methods. The Implicit Association Test (IAT) and Brief IAT (BIAT) showed the best overall psychometric quality, followed by the Go–No-Go association task, Single-Target IAT (ST-IAT), Affective Misattribution Procedure (AMP), Sorting Paired Features task, and Evaluative Priming. The AMP showed a steep decline in its psychometric qualities when people with extreme attitude scores were removed. Single-category attitude scores computed for the IAT and BIAT showed good relationships with other attitude measures but no evidence of discriminant validity between paired categories. The other measures, especially the AMP and ST-IAT, showed better evidence for discriminant validity. These results inform us on the validity of the measures as attitude assessments, but do not speak to the implicitness of the measured constructs.

  20. Indirect search for New Physics: complementarity to direct searches

    CERN Document Server

    Mahmoudi, F

    2013-01-01

    We present an overview on the interplay between direct searches for new physics at the LHC and indirect constraints from the flavour sector, with an emphasis on the implications of the recent LHCb results. The complementarity with the Higgs search results will also be addressed. We show the correlation and complementarity between the different sectors in the context of a few specific examples in supersymmetry.

  1. Indirect Self-Destructiveness in Women who Experience Domestic Violence.

    Science.gov (United States)

    Tsirigotis, Konstantinos; Łuczak, Joanna

    2018-01-02

    Lives of people experiencing domestic or/and intimate partner violence abound in many unpleasant events and physical and psychological suffering, which affects their psychosocial functioning. The aim of this study was to explore indirect self-destructiveness as a generalised behavioural tendency and its manifestations in women experiencing domestic violence. The "Chronic Self-Destructiveness Scale" (CS-DS) was used to study two groups of women: 52 women aged 30-65 years (mean age: 40.15) using assistance of the Crisis Intervention Centre due to experienced domestic violence (V group) and 150 well-matched women not experiencing domestic violence (NV group). Women suffering domestic violence (V) obtained significantly higher scores than women not experiencing domestic violence (NV) for both the general index and a majority of CS-DS subscales; it was only for the A1 (Transgression and Risk) subscale that they achieved somewhat lower scores. Correlation coefficients between particular CS-DS subscales in the V group were higher than in the NV group; there were also certain differences in coefficients between the groups. Subscale factor analysis results were different too: only one factor was isolated in the V group while two were distinguished in the NV group. It can be inferred from the results that the intensity of indirect self-destructiveness as a generalised behavioural tendency as well as of most its categories was higher in women experiencing domestic violence. Tendencies and categories of indirectly self-destructive behaviours in women suffering domestic violence were more closely connected with one another, and the internal coherence of indirect self-destructiveness in those women might also be higher.

  2. Hybrid Instruments and the Indirect Credit Method - Does it work?

    OpenAIRE

    Wiedermann-Ondrej, Nadine

    2007-01-01

    This paper analyses the possibility of double non-taxation of hybrid instruments in cross border transactions where the country of the investor has implemented the indirect credit method for mitigation or elimination of double taxation. From an isolated perspective a double non-taxation cannot be obtained because typically no taxes are paid in the foreign country due to the classification as debt and therefore even in the case of a classification as a dividend in the country of the investor n...

  3. Steam generators in indirect-cycle water-cooled reactors

    International Nuclear Information System (INIS)

    Fajeau, M.

    1976-01-01

    In the indirect cycle water-cooled nuclear reactors, the steam generators are placed between the primary circuit and the turbine. They act both as an energy transmitter and as a leaktigh barrier against fission or corrosion products. Their study is thus very important from a performance and reliability point of view. Two main types are presented here: the U-tube and the once-through steam generators [fr

  4. Accuracy of five intraoral scanners compared to indirect digitalization.

    Science.gov (United States)

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  5. Known unknowns: indirect energy effects of information and communication technology

    Science.gov (United States)

    Horner, Nathaniel C.; Shehabi, Arman; Azevedo, Inês L.

    2016-10-01

    Background. There has been sustained and growing interest in characterizing the net energy impact of information and communication technology (ICT), which results from indirect effects offsetting (or amplifying) the energy directly consumed by ICT equipment. These indirect effects may be either positive or negative, and there is considerable disagreement as to the direction of this sign as well as the effect magnitude. Literature in this area ranges from studies focused on a single service (such as e-commerce versus traditional retail) to macroeconomic studies attempting to characterize the overall impact of ICT. Methods. We review the literature on the indirect energy effect of ICT found via Google Scholar, our own research, and input from other researchers in the field. The various studies are linked to an effect taxonomy, which is synthesized from several different hierarchies present in the literature. References are further grouped according to ICT service (e.g., e-commerce, telework) and summarized by scope, method, and quantitative and qualitative findings. Review results. Uncertainty persists in understanding the net energy effects of ICT. Results of indirect energy effect studies are highly sensitive to scoping decisions and assumptions made by the analyst. Uncertainty increases as the impact scope broadens, due to complex and interconnected effects. However, there is general agreement that ICT has large energy savings potential, but that the realization of this potential is highly dependent on deployment details and user behavior. Discussion. While the overall net effect of ICT is likely to remain unknown, this review suggests several guidelines for improving research quality in this area, including increased data collection, enhancing traditional modeling studies with sensitivity analysis, greater care in scoping, less confidence in characterizing aggregate impacts, more effort on understanding user behavior, and more contextual integration across the

  6. Reactor Materials Program process water piping indirect failure frequency

    International Nuclear Information System (INIS)

    Daugherty, W.L.

    1989-01-01

    Following completion of the probabilistic analyses, the LOCA Definition Project has been subject to various external reviews, and as a result the need for several revisions has arisen. This report updates and summarizes the indirect failure frequency analysis for the process water piping. In this report, a conservatism of the earlier analysis is removed, supporting lower failure frequency estimates. The analysis results are also reinterpreted in light of subsequent review comments

  7. Direct and Indirect Effects of Climate Change on Amphibian Populations

    OpenAIRE

    Blaustein, Andrew R.; Walls, Susan C.; Bancroft, Betsy A.; Lawler, Joshua J.; Searle, Catherine L.; Gervasi, Stephanie S.

    2010-01-01

    As part of an overall decline in biodiversity, populations of many organisms are declining and species are being lost at unprecedented rates around the world. This includes many populations and species of amphibians. Although numerous factors are affecting amphibian populations, we show potential direct and indirect effects of climate change on amphibians at the individual, population and community level. Shifts in amphibian ranges are predicted. Changes in climate may affect survival, growth...

  8. An experimental test for indirect benefits in Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Ödeen Anders

    2007-03-01

    Full Text Available Abstract Background Despite much empirical attention, tests for indirect benefits of mate choice have rarely considered the major components of sexual and nonsexual offspring fitness relevant to a population. Here we use a novel experimental design to test for the existence of any indirect benefits in a laboratory adapted population of D. melanogaster. Our experiment compared the fitness (mating success, longevity, and productivity of individuals possessing genomes that derived two generations previously from males that were either entirely successful (studs or wholly unsuccessful (duds at achieving mates in three subsequent rounds of mating trials. Results Males from the stud treatment were 30% more successful on average at securing mates than males from the dud treatment. In contrast, we found no difference between treatments in measures of productivity or of longevity when measured in a mixed-sex environment. In the absence of females, however, males in the stud treatment outlived males in the dud treatment. Conclusion Our results suggest that mating with successful males in this population provides an indirect benefit to females and that, at least in this environment, the benefit arises primarily through the production of more attractive male offspring. However, it is unclear whether this represents solely a traditional sexy sons benefit or whether there is an additional good genes component (with male offspring simply allocating their surplus condition to traits that enhance their mating success. The lack of any detectable differences in female fitness between the two treatments suggests the former, although the longevity advantage of males in the stud treatment when females were absent is consistent with the latter. Determining the effect of this indirect benefit on the evolution of female mate preferences (or resistance will require comparable data on the direct costs of mating with various males, and an understanding of how these costs

  9. Effective dose from direct and indirect digital panoramic units

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Sun; Kim, Jin Soo; Seo, Yo Seob; Kim, Jae Duk [School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2013-06-15

    This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. The effective doses of the 4 digital panoramic units ranged between 8.9 {mu}Sv and 37.8 {mu}Sv. By using the head phantom, the effective doses from the direct digital panoramic units (37.8 {mu}Sv, 27.6 {mu}Sv) were higher than those from the indirect units (8.9 {mu}Sv, 15.9 {mu}Sv). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

  10. Evaluation of bone surrogates for indirect and direct ballistic fractures.

    Science.gov (United States)

    Bir, Cynthia; Andrecovich, Chris; DeMaio, Marlene; Dougherty, Paul J

    2016-04-01

    The mechanism of injury for fractures to long bones has been studied for both direct ballistic loading as well as indirect. However, the majority of these studies have been conducted on both post-mortem human subjects (PMHS) and animal surrogates which have constraints in terms of storage, preparation and testing. The identification of a validated bone surrogate for use in forensic, medical and engineering testing would provide the ability to investigate ballistic loading without these constraints. Two specific bone surrogates, Sawbones and Synbone, were evaluated in comparison to PMHS for both direct and indirect ballistic loading. For the direct loading, the mean velocity to produce fracture was 121 ± 19 m/s for the PMHS, which was statistically different from the Sawbones (140 ± 7 m/s) and Synbone (146 ± 3 m/s). The average distance to fracture in the indirect loading was .70 cm for the PMHS. The Synbone had a statistically similar average distance to fracture (.61 cm, p=0.54) however the Sawbones average distance to fracture was statistically different (.41 cm, pballistic testing was not identified and future work is warranted. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. [Methodologies for estimating the indirect costs of traffic accidents].

    Science.gov (United States)

    Carozzi, Soledad; Elorza, María Eugenia; Moscoso, Nebel Silvana; Ripari, Nadia Vanina

    2017-01-01

    Traffic accidents generate multiple costs to society, including those associated with the loss of productivity. However, there is no consensus about the most appropriate methodology for estimating those costs. The aim of this study was to review methods for estimating indirect costs applied in crash cost studies. A thematic review of the literature was carried out between 1995 and 2012 in PubMed with the terms cost of illness, indirect cost, road traffic injuries, productivity loss. For the assessment of costs we used the the human capital method, on the basis of the wage-income lost during the time of treatment and recovery of patients and caregivers. In the case of premature death or total disability, the discount rate was applied to obtain the present value of lost future earnings. The computed years arose by subtracting to life expectancy at birth the average age of those affected who are not incorporated into the economically active life. The interest in minimizing the problem is reflected in the evolution of the implemented methodologies. We expect that this review is useful to estimate efficiently the real indirect costs of traffic accidents.

  12. Stem cell monitoring with a direct or indirect labeling method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Hwan; Lee, Yong Jin [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)

    2016-12-15

    The molecular imaging techniques allow monitoring of the transplanted cells in the same individuals over time, from early localization to the survival, migration, and differentiation. Generally, there are two methods of stem cell labeling: direct and indirect labeling methods. The direct labeling method introduces a labeling agent into the cell, which is stably incorporated or attached to the cells prior to transplantation. Direct labeling of cells with radionuclides is a simple method with relatively fewer adverse events related to genetic responses. However, it can only allow short-term distribution of transplanted cells because of the decreasing imaging signal with radiodecay, according to the physical half-lives, or the signal becomes more diffuse with cell division and dispersion. The indirect labeling method is based on the expression of a reporter gene transduced into the cell before transplantation, which is then visualized upon the injection of an appropriate probe or substrate. In this review, various imaging strategies to monitor the survival and behavior change of transplanted stem cells are covered. Taking these new approaches together, the direct and indirect labeling methods may provide new insights on the roles of in vivo stem cell monitoring, from bench to bedside.

  13. and Indigenous Indirect Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Annapurna S. Agasthya

    2012-01-01

    Full Text Available Brucellosis is one of the most important reemerging zoonoses in many countries. Brucellosis is caused by Gram-negative coccobacillus belonging to genus Brucella. Human brucellosis often makes the diagnosis difficult. The symptoms and clinical signs most commonly reported are fever, fatigue, malaise, chills, sweats headaches, myalgia, arthralgia, and weight loss. Some cases have been presented with only joint pain, lower backache, and involuntary limb movement, burning feet, or ischemic heart attacks. The focus of this work was to develop a highly sensitive and specific indirect ELISA by using smooth lipopolysaccharide antigen of Brucella abortus 99 to detect anti-Brucella antibodies at Project Directorate on Animal Disease Monitoring and Surveillance. Serum samples collected from 652 individuals in whom fever was not the major symptom but the complaint was of joint pain, headache, lower backache, and so forth, were screened by Rose Bengal plate agglutination test (RBPT and standard tube agglutination test (STAT. Subsequent testing of sera by indigenous indirect ELISA detected 20 samples positive (3.6% seroprevalence, and indirect ELISA was found to be more sensitive than RBPT and STAT. The seroprevalence in South Karnataka was 2.14%, and in North Karnataka it was 0.92%.

  14. Indirect radiation effects related to the environmental structure of targets

    International Nuclear Information System (INIS)

    Frankenberg, D.

    1976-01-01

    It is supposed, that in biological systems there are direct as well as indirect radiation effects. Their contributions to lethal effects depend mainly on two different kinds of structures within irradiated systems: the microscopic energy deposition patterns of radiation and the environmental structures of targets. The approach to determine these contributions of the lethal action of ionizing radiation in yeast cells was, to use chemical compounds, which specifically change the radical spectrum of water radiolysis. The efficiency of such chemical compounds in scavenging specifically water radicals was tested in aqueous solutions of thymine molecules, in which indirect radiation effects occur exclusively. The main result is, that the OH'-radical is by far the most effective radical to destroy thymine molecules. The relative contributions of direct and indirect radiation effects to lethal actions of ionizing radiation was investigated in yeast cells. The radical spectrum of water radiolysis was changed by bubbling the cell suspensions with different gases. The main result is, that there are no lethal radiation effects du to the action of water radicals

  15. Indirect Detection Analysis: Wino Dark Matter Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Hryczuk, Andrzej [Munich, Tech. U.; Cholis, Ilias [Fermilab; Iengo, Roberto [SISSA, Trieste; Tavakoli, Maryam [IPM, Tehran; Ullio, Piero [INFN, Trieste

    2014-07-15

    We perform a multichannel analysis of the indirect signals for the Wino Dark Matter, including one-loop electroweak and Sommerfeld enhancement corrections. We derive limits from cosmic ray antiprotons and positrons, from continuum galactic and extragalactic diffuse γ-ray spectra, from the absence of γ-ray line features at the galactic center above 500 GeV in energy, from γ-rays toward nearby dwarf spheroidal galaxies and galaxy clusters, and from CMB power-spectra. Additionally, we show the future prospects for neutrino observations toward the inner Galaxy and from antideuteron searches. For each of these indirect detection probes we include and discuss the relevance of the most important astrophysical uncertainties that can impact the strength of the derived limits. We find that the Wino as a dark matter candidate is excluded in the mass range bellow simeq 800 GeV from antiprotons and between 1.8 and 3.5 TeV from the absence of a γ-ray line feature toward the galactic center. Limits from other indirect detection probes confirm the main bulk of the excluded mass ranges.

  16. Evidence of indirect gap in monolayer WSe2

    KAUST Repository

    Hsu, Wei-Ting

    2017-10-09

    Monolayer transition metal dichalcogenides, such as MoS2 and WSe2, have been known as direct gap semiconductors and emerged as new optically active materials for novel device applications. Here we reexamine their direct gap properties by investigating the strain effects on the photoluminescence of monolayer MoS2 and WSe2. Instead of applying stress, we investigate the strain effects by imaging the direct exciton populations in monolayer WSe2–MoS2 and MoSe2–WSe2 lateral heterojunctions with inherent strain inhomogeneity. We find that unstrained monolayer WSe2 is actually an indirect gap material, as manifested in the observed photoluminescence intensity–energy correlation, from which the difference between the direct and indirect optical gaps can be extracted by analyzing the exciton thermal populations. Our findings combined with the estimated exciton binding energy further indicate that monolayer WSe2 exhibits an indirect quasiparticle gap, which has to be reconsidered in further studies for its fundamental properties and device applications.

  17. The evolution of conditional moral assessment in indirect reciprocity

    Science.gov (United States)

    Sasaki, Tatsuya; Okada, Isamu; Nakai, Yutaka

    2017-01-01

    Indirect reciprocity is a major mechanism in the maintenance of cooperation among unrelated individuals. Indirect reciprocity leads to conditional cooperation according to social norms that discriminate the good (those who deserve to be rewarded with help) and the bad (those who should be punished by refusal of help). Despite intensive research, however, there is no definitive consensus on what social norms best promote cooperation through indirect reciprocity, and it remains unclear even how those who refuse to help the bad should be assessed. Here, we propose a new simple norm called “Staying” that prescribes abstaining from assessment. Under the Staying norm, the image of the person who makes the decision to give help stays the same as in the last assessment if the person on the receiving end has a bad image. In this case, the choice about whether or not to give help to the potential receiver does not affect the image of the potential giver. We analyze the Staying norm in terms of evolutionary game theory and demonstrate that Staying is most effective in establishing cooperation compared to the prevailing social norms, which rely on constant monitoring and unconditional assessment. The application of Staying suggests that the strict application of moral judgment is limited. PMID:28150808

  18. Indirect-fired gas turbine bottomed with fuel cell

    Science.gov (United States)

    Micheli, P.L.; Williams, M.C.; Parsons, E.L.

    1995-09-12

    An indirect-heated gas turbine cycle is bottomed with a fuel cell cycle with the heated air discharged from the gas turbine being directly utilized at the cathode of the fuel cell for the electricity-producing electrochemical reaction occurring within the fuel cell. The hot cathode recycle gases provide a substantial portion of the heat required for the indirect heating of the compressed air used in the gas turbine cycle. A separate combustor provides the balance of the heat needed for the indirect heating of the compressed air used in the gas turbine cycle. Hot gases from the fuel cell are used in the combustor to reduce both the fuel requirements of the combustor and the NOx emissions therefrom. Residual heat remaining in the air-heating gases after completing the heating thereof is used in a steam turbine cycle or in an absorption refrigeration cycle. Some of the hot gases from the cathode can be diverted from the air-heating function and used in the absorption refrigeration cycle or in the steam cycle for steam generating purposes. 1 fig.

  19. N2-fixing red alder indirectly accelerates ecosystem nitrogen cycling

    Science.gov (United States)

    Perakis, Steven S.; Matkins, Joselin J.; Hibbs, David E.

    2012-01-01

    Symbiotic N2-fixing tree species can accelerate ecosystem N dynamics through decomposition via direct pathways by producing readily decomposed leaf litter and increasing N supply to decomposers, as well as via indirect pathways by increasing tissue and detrital N in non-fixing vegetation. To evaluate the relative importance of these pathways, we compared three-year decomposition and N dynamics of N2-fixing red alder leaf litter (2.34 %N) to both low-N (0.68 %N) and high-N (1.21 %N) litter of non-fixing Douglas-fir, and decomposed each litter source in four forests dominated by either red alder or Douglas-fir. We also used experimental N fertilization of decomposition plots to assess elevated N availability as a potential mechanism of N2-fixer effects on litter mass loss and N dynamics. Direct effects of N2-fixing red alder on decomposition occurred primarily as faster N release from red alder than Douglas-fir litter, but direct increases in N supply to decomposers via fertilization did not stimulate decomposition of any litter. Fixed N indirectly influenced detrital dynamics by increasing Douglas-fir tissue and litter N concentrations, which accelerated litter N release without accelerating mass loss. By increasing soil N, tissue N, and the rate of N release from litter of non-fixers, we conclude that N2-fixing vegetation can indirectly foster plant-soil feedbacks that contribute to the persistence of elevated N availability in terrestrial ecosystems.

  20. Forgotten carbon: indirect CO2 in greenhouse gas emission inventories

    International Nuclear Information System (INIS)

    Gillenwater, Michael

    2008-01-01

    National governments that are Parties to the United Nations Framework Convention on Climate Change (UNFCCC) are required to submit greenhouse gas (GHG) inventories accounting for the emissions and removals occurring within their geographic territories. The Intergovernmental Panel on Climate Change (IPCC) provides inventory methodology guidance to the Parties of the UNFCCC. This methodology guidance, and national inventories based on it, omits carbon dioxide (CO 2 ) from the atmospheric oxidation of methane, carbon monoxide, and non-methane volatile organic compounds emissions that result from several source categories. The inclusion of this category of 'indirect' CO 2 in GHG inventories increases global anthropogenic emissions (excluding land use and forestry) between 0.5 and 0.7%. However, the effect of inclusion on aggregate UNFCCC Annex I Party GHG emissions would be to reduce the growth of total emissions, from 1990 to 2004, by 0.2% points. The effect on the GHG emissions and emission trends of individual countries varies. The paper includes a methodology for calculating these emissions and discusses uncertainties. Indirect CO 2 is equally relevant for GHG inventories at other scales, such as global, regional, organizational, and facility. Similarly, project-based methodologies, such as those used under the Clean Development Mechanism, may need revising to account for indirect CO 2

  1. Direct and Indirect Dark Matter Detection in Gauge Theories

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Farinaldo [Federal Univ. of Paraba (Brazil)

    2013-01-01

    The Dark matter (DM) problem constitutes a key question at the interface among Particle Physics, Astrophysics and Cosmology. The observational data which have been accumulated in the last years point to an existence of non baryonic amount of DM. Since the Standard Model (SM) does not provide any candidate for such non-baryonic DM, the evidence of DM is a major indication for new physics beyond the SM. We will study in this work one of the most popular DM candidates, the so called WIMPs (Weakly Interacting Massive Particles) from a direct and indirect detection perspective. In order to approach the direct and indirect dection of DM in the context of Particle Physics in a more pedagogic way, we will begin our discussion talking about a minimal extension of the SM. Later we will work on the subject in a 3-3-1 model. Next, we will study the role of WIMPs in the Big Bang Nucleosynthesis. Lastly, we will look for indirect DM signals in the center of our galaxy using the NASA Satellite, called Fermi-LAT. Through a comprehensive analysis of the data events observed by Fermi-LAT and some background models, we will constrain the dark matter annihilation cross section for several annihilation channels and dark matter halo profiles.

  2. Direct and Indirect Pathways From Social Support to Health?

    Science.gov (United States)

    Kim, Seoyoun; Thomas, Patricia A

    2017-07-04

    We aimed to investigate potential direct and indirect pathways linking social support and health, while considering mental health and chronic inflammation as inter-related outcomes. The study also contributes to the literature through testing potential bidirectional relationships between social support, mental health, and chronic inflammation. This study uses Structural Equation Modeling and two waves of the National Social Life, Health, and Aging Project (NSHAP), including 1,124 community-living older adults aged 57-85 years at Wave 1 (2005). Analyses show that social support influenced mental health indirectly through better self-esteem. Moreover, social support was associated with lower levels of chronic inflammation but chronic inflammation did not influence social support. The growing number of older adults with an aging population urgently calls for a greater understanding of factors influencing their physical and mental health. The results of this study demonstrate the importance of social support in older adults' health, while specifically focusing on understudied indirect pathways from social support to health. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Indirect Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The indirect competitive ELISA (indirect cELISA) pits plate-immobilized antigen against antigens in solution for binding to antigen-specific antibody. The antigens in solution are in the test sample and are first incubated with antigen-specific antibody. These antibody-antigen complexes are then added to microtiter plates whose wells have been coated with purified antigen. The wells are washed to remove unbound antigen-antibody complexes and free antigen. A reporter-labeled secondary antibody is then added followed by the addition of substrate. Substrate hydrolysis yields a signal that is inversely proportional to antigen concentration within the sample. This is because when antigen concentration is high in the test sample, most of the antibody is bound before adding the solution to the plate. Most of the antibody remains in solution (as complexes) and is thus washed away before the addition of the reporter-labeled secondary antibody and substrate. Thus, the higher the antigen concentration in the test sample, the weaker the resultant signal in the detection step. The indirect cELISA is often used for competitive detection and quantification of antibodies against viral diseases in biological samples. © 2017 Cold Spring Harbor Laboratory Press.

  4. Partner Choice Drives the Evolution of Cooperation via Indirect Reciprocity.

    Directory of Open Access Journals (Sweden)

    Gilbert Roberts

    Full Text Available Indirect reciprocity potentially provides an important means for generating cooperation based on helping those who help others. However, the use of 'image scores' to summarize individuals' past behaviour presents a dilemma: individuals withholding help from those of low image score harm their own reputation, yet giving to defectors erodes cooperation. Explaining how indirect reciprocity could evolve has therefore remained problematic. In all previous treatments of indirect reciprocity, individuals are assigned potential recipients and decide whether to cooperate or defect based on their reputation. A second way of achieving discrimination is through partner choice, which should enable individuals to avoid defectors. Here, I develop a model in which individuals choose to donate to anyone within their group, or to none. Whereas image scoring with random pairing produces cycles of cooperation and defection, with partner choice there is almost maximal cooperation. In contrast to image scoring with random pairing, partner choice results in almost perfect contingency, producing the correlation between giving and receiving required for cooperation. In this way, partner choice facilitates much higher and more stable levels of cooperation through image scoring than previously reported and provides a simple mechanism through which systems of helping those who help others can work.

  5. The evolution of conditional moral assessment in indirect reciprocity.

    Science.gov (United States)

    Sasaki, Tatsuya; Okada, Isamu; Nakai, Yutaka

    2017-02-02

    Indirect reciprocity is a major mechanism in the maintenance of cooperation among unrelated individuals. Indirect reciprocity leads to conditional cooperation according to social norms that discriminate the good (those who deserve to be rewarded with help) and the bad (those who should be punished by refusal of help). Despite intensive research, however, there is no definitive consensus on what social norms best promote cooperation through indirect reciprocity, and it remains unclear even how those who refuse to help the bad should be assessed. Here, we propose a new simple norm called "Staying" that prescribes abstaining from assessment. Under the Staying norm, the image of the person who makes the decision to give help stays the same as in the last assessment if the person on the receiving end has a bad image. In this case, the choice about whether or not to give help to the potential receiver does not affect the image of the potential giver. We analyze the Staying norm in terms of evolutionary game theory and demonstrate that Staying is most effective in establishing cooperation compared to the prevailing social norms, which rely on constant monitoring and unconditional assessment. The application of Staying suggests that the strict application of moral judgment is limited.

  6. The evolution of conditional moral assessment in indirect reciprocity

    Science.gov (United States)

    Sasaki, Tatsuya; Okada, Isamu; Nakai, Yutaka

    2017-02-01

    Indirect reciprocity is a major mechanism in the maintenance of cooperation among unrelated individuals. Indirect reciprocity leads to conditional cooperation according to social norms that discriminate the good (those who deserve to be rewarded with help) and the bad (those who should be punished by refusal of help). Despite intensive research, however, there is no definitive consensus on what social norms best promote cooperation through indirect reciprocity, and it remains unclear even how those who refuse to help the bad should be assessed. Here, we propose a new simple norm called “Staying” that prescribes abstaining from assessment. Under the Staying norm, the image of the person who makes the decision to give help stays the same as in the last assessment if the person on the receiving end has a bad image. In this case, the choice about whether or not to give help to the potential receiver does not affect the image of the potential giver. We analyze the Staying norm in terms of evolutionary game theory and demonstrate that Staying is most effective in establishing cooperation compared to the prevailing social norms, which rely on constant monitoring and unconditional assessment. The application of Staying suggests that the strict application of moral judgment is limited.

  7. Identification of Methodology of Indirect Assessment of Economy Shadowing

    Directory of Open Access Journals (Sweden)

    Avhustyn Ruslan R.

    2014-03-01

    Full Text Available The article explains the essence of the shadow economy as an objective phenomenon of socio-economic relations and its influence upon national economy security through instruments of pricing, fiscal restrictions, tax control, and banking and insurance regulation. It proves the necessity of use of the indirect method of assessment of the level of economy shadowing along with methods of direct control over the growth of shadowed economic relations, since such an approach would allow rational approach to identification of volumes and level of shadow activity. In the result of the study the article marks out varieties of indirect assessment of economy shadowing (methods of document, accounting and economic analysis, their specific features, advantages and shortcomings and results of practical use. The article reveals approaches and indicators of economic analysis that allow identification of reasons of deviations from the normal economic activity of economic subjects. It provides examples of the indirect method of assessment of the volume of shadowed economy that deal with analysis of demand on money and comparison of rates of the growth of the money supply with the volume of sight drafts with GDP.

  8. Groupwise information sharing promotes ingroup favoritism in indirect reciprocity

    Directory of Open Access Journals (Sweden)

    Nakamura Mitsuhiro

    2012-11-01

    Full Text Available Abstract Background Indirect reciprocity is a mechanism for cooperation in social dilemma situations. In indirect reciprocity, an individual is motivated to help another to acquire a good reputation and receive help from others afterwards. Another aspect of human cooperation is ingroup favoritism, whereby individuals help members in their own group more often than those in other groups. Ingroup favoritism is a puzzle for the theory of cooperation because it is not easily evolutionarily stable. In the context of indirect reciprocity, ingroup favoritism has been shown to be a consequence of employing a double standard when assigning reputations to ingroup and outgroup members. An example of such a double standard is the situation in which helping an ingroup member is regarded as good, whereas the same action toward an outgroup member is regarded as bad. Results We analyze a computational model of indirect reciprocity in which information sharing is conducted groupwise. In our model, individuals play social dilemma games within and across groups, and the information about their reputations is shared within each group. We show that evolutionarily stable ingroup favoritism emerges even if all the players use the same reputation assignment rule regardless of group (i.e., a single standard. Two reputation assignment rules called simple standing and stern judging yield ingroup favoritism; under these rules, cooperation with (defection against good individuals is regarded as good (bad and defection against bad individuals is regarded as good. Stern judging induces much stronger ingroup favoritism than does simple standing. Simple standing and stern judging are evolutionarily stable against each other when groups employing different assignment rules compete and the number of groups is sufficiently large. In addition, we analytically show as a limiting case that homogeneous populations of reciprocators that use reputations are unstable when individuals

  9. How important is organic aerosol hygroscopicity to aerosol indirect forcing?

    International Nuclear Information System (INIS)

    Liu Xiaohong; Wang Jian

    2010-01-01

    Organics are among the most abundant aerosol components in the atmosphere. However, there are still large uncertainties with emissions of primary organic aerosol (POA) and volatile organic compounds (VOCs) (precursor gases of secondary organic aerosol, SOA), formation of SOA, and chemical and physical properties (e.g., hygroscopicity) of POA and SOA. All these may have significant impacts on aerosol direct and indirect forcing estimated from global models. In this study a modal aerosol module (MAM) in the NCAR community atmospheric model (CAM) is used to examine sensitivities of aerosol indirect forcing to hygroscopicity (represented by a single parameter 'κ' ) of POA and SOA. Our model simulation indicates that in the present-day (PD) condition changing the 'κ' value of POA from 0 to 0.1 increases the number concentration of cloud condensational nuclei (CCN) at supersaturation S = 0.1% by 40-80% over the POA source regions, while changing the 'κ' value of SOA by ± 50% (from 0.14 to 0.07 and 0.21) changes the CCN concentration within 40%. There are disproportionally larger changes in CCN concentration in the pre-industrial (PI) condition. Due to the stronger impact of organics hygroscopicity on CCN and cloud droplet number concentration at PI condition, global annual mean anthropogenic aerosol indirect forcing (AIF) between PD and PI conditions reduces with the increase of the hygroscopicity of organics. Global annual mean AIF varies by 0.4 W m -2 in the sensitivity runs with the control run of - 1.3 W m -2 , highlighting the need for improved understanding of organics hygroscopicity and its representation in global models.

  10. Assessing Mediational Models: Testing and Interval Estimation for Indirect Effects.

    Science.gov (United States)

    Biesanz, Jeremy C; Falk, Carl F; Savalei, Victoria

    2010-08-06

    Theoretical models specifying indirect or mediated effects are common in the social sciences. An indirect effect exists when an independent variable's influence on the dependent variable is mediated through an intervening variable. Classic approaches to assessing such mediational hypotheses ( Baron & Kenny, 1986 ; Sobel, 1982 ) have in recent years been supplemented by computationally intensive methods such as bootstrapping, the distribution of the product methods, and hierarchical Bayesian Markov chain Monte Carlo (MCMC) methods. These different approaches for assessing mediation are illustrated using data from Dunn, Biesanz, Human, and Finn (2007). However, little is known about how these methods perform relative to each other, particularly in more challenging situations, such as with data that are incomplete and/or nonnormal. This article presents an extensive Monte Carlo simulation evaluating a host of approaches for assessing mediation. We examine Type I error rates, power, and coverage. We study normal and nonnormal data as well as complete and incomplete data. In addition, we adapt a method, recently proposed in statistical literature, that does not rely on confidence intervals (CIs) to test the null hypothesis of no indirect effect. The results suggest that the new inferential method-the partial posterior p value-slightly outperforms existing ones in terms of maintaining Type I error rates while maximizing power, especially with incomplete data. Among confidence interval approaches, the bias-corrected accelerated (BC a ) bootstrapping approach often has inflated Type I error rates and inconsistent coverage and is not recommended; In contrast, the bootstrapped percentile confidence interval and the hierarchical Bayesian MCMC method perform best overall, maintaining Type I error rates, exhibiting reasonable power, and producing stable and accurate coverage rates.

  11. Total, direct, and indirect effects of paan on oral cancer.

    Science.gov (United States)

    Merchant, Anwar T; Pitiphat, Waranuch

    2015-03-01

    Paan (betel leaf and betel nut quid) used with or without tobacco has been positively associated with oral cancer. Oral submucous fibrosis (OSMF), a precancerous condition caused by paan, lies on the causal pathway between paan use and oral cancer. The purpose of this analysis was to estimate the effect of paan consumption on oral cancer risk when it is mediated by OSMF. We used mediation methods proposed by VanderWeele, which are based on causal inference principles, to characterize the total, direct, and indirect effects of paan, consumed with and without tobacco, on oral cancer mediated by OSMF. We reanalyzed case-control data collected from three hospitals in Karachi, Pakistan, between July 1996 and March 1998. For paan without tobacco, the total effect on oral cancer was OR 7.39, 95 % CI 1.01, 38.11, the natural indirect effect (due to OSMF among paan users) was OR 2.48, 95 % CI 0.99, 10.44, and the natural direct effect (due to paan with OSMF absent) was OR 3.32, 95 % CI 0.68, 10.07. For paan with tobacco, the total direct effect was OR 15.68, 95 % CI 3.00, 54.90, the natural indirect effect was OR 2.18, 95 % CI 0.82, 5.52, and the natural direct effect was OR 7.27, 95 % CI 2.15, 20.43. Paan, whether or not it contained tobacco, raised oral cancer risk irrespective of OSMF. Oral cancer risk was higher among those who used paan with tobacco.

  12. Contaminants as viral cofactors: assessing indirect population effects

    Science.gov (United States)

    Springman, Katherine R.; Kurath, Gael; Anderson, James J.; Emlen, John M.

    2005-01-01

    Current toxicological methods often miss contaminant effects, particularly when immune suppression is involved. The failure to recognize and evaluate indirect and sublethal effects severely limits the applicability of those methods at the population level. In this study, the Vitality model is used to evaluate the population level effects of a contaminant exerting only indirect, sublethal effects at the individual level. Juvenile rainbow trout (Oncorhynchus mykiss) were injected with 2.5 or 10.0 mg/kg doses of the model CYP1A inducer, β-naphthoflavone (BNF) as a pre-stressor, then exposed to a challenge dose of 102 or 104 pfu/fish of infectious hematopoietic necrosis virus (IHNV), an important viral pathogen of salmonids in North America. At the end of the 28-d challenge, the mortality data were processed according to the Vitality model which indicated that the correlation between the average rate of vitality loss and the pre-stressor dose was strong:R2 = 0.9944. Average time to death and cumulative mortality were dependent on the BNF dose, while no significant difference between the two viral dosages was shown, implying that the history of the organism at the time of stressor exposure is an important factor in determining the virulence or toxicity of the stressor. The conceptual framework of this model permits a smoother transfer of results to a more complex stratum, namely the population level, which allows the immunosuppressive results generated by doses of a CYP1A inducer that more accurately represent the effects elicited by environmentally-relevant contaminant concentrations to be extrapolated to target populations. The indirect effects of other environmental contaminants with similar biotransformation pathways, such as polycyclic aromatic hydrocarbons (PAH), could be assessed and quantified with this model and the results applied to a more complex biological hierarchy.

  13. Bose-Einstein condensation and indirect excitons: a review.

    Science.gov (United States)

    Combescot, Monique; Combescot, Roland; Dubin, François

    2017-06-01

    We review recent progress on Bose-Einstein condensation (BEC) of semiconductor excitons. The first part deals with theory, the second part with experiments. This Review is written at a time where the problem of exciton Bose-Einstein condensation has just been revived by the understanding that the exciton condensate must be dark because the exciton ground state is not coupled to light. Here, we theoretically discuss this missed understanding before providing its experimental support through experiments that scrutinize indirect excitons made of spatially separated electrons and holes. The theoretical part first discusses condensation of elementary bosons. In particular, the necessary inhibition of condensate fragmentation by exchange interaction is stressed, before extending the discussion to interacting bosons with spin degrees of freedom. The theoretical part then considers composite bosons made of two fermions like semiconductor excitons. The spin structure of the excitons is detailed, with emphasis on the crucial fact that ground-state excitons are dark: indeed, this imposes the exciton Bose-Einstein condensate to be not coupled to light in the dilute regime. Condensate fragmentations are then reconsidered. In particular, it is shown that while at low density, the exciton condensate is fully dark, it acquires a bright component, coherent with the dark one, beyond a density threshold: in this regime, the exciton condensate is 'gray'. The experimental part first discusses optical creation of indirect excitons in quantum wells, and the detection of their photoluminescence. Exciton thermalisation is also addressed, as well as available approaches to estimate the exciton density. We then switch to specific experiments where indirect excitons form a macroscopic fragmented ring. We show that such ring provides efficient electrostatic trapping in the region of the fragments where an essentially-dark exciton Bose-Einstein condensate is formed at sub-Kelvin bath

  14. Laser based analysis using a passively Q-switched laser employing analysis electronics and a means for detecting atomic optical emission of the laser media

    Science.gov (United States)

    Woodruff, Steven D.; Mcintyre, Dustin L.

    2016-03-29

    A device for Laser based Analysis using a Passively Q-Switched Laser comprising an optical pumping source optically connected to a laser media. The laser media and a Q-switch are positioned between and optically connected to a high reflectivity mirror (HR) and an output coupler (OC) along an optical axis. The output coupler (OC) is optically connected to the output lens along the optical axis. A means for detecting atomic optical emission comprises a filter and a light detector. The optical filter is optically connected to the laser media and the optical detector. A control system is connected to the optical detector and the analysis electronics. The analysis electronics are optically connected to the output lens. The detection of the large scale laser output production triggers the control system to initiate the precise timing and data collection from the detector and analysis.

  15. An ultra-long cavity passively mode-locked fiber laser based on nonlinear polarization rotation in a semiconductor optical amplifier

    International Nuclear Information System (INIS)

    Liu, Tonghui; Jia, Dongfang; Yang, Jingwen; Chen, Jiong; Wang, Zhaoying; Yang, Tianxin

    2013-01-01

    In this paper we investigate an ultra-long cavity passively mode-locked fiber laser based on a semiconductor optical amplifier (SOA). Experimental results are presented which indicate that stable mode-locked pulses can be obtained by combining nonlinear polarization rotation (NPR) in the SOA with a polarization controller. By adding a 4 km single mode fiber into the ring cavity, a stable fundamental-order mode-locked pulse train with a repetition rate of 50.72 kHz is generated through the NPR effect in the SOA. The central wavelength, 3 dB bandwidth and single pulse energy of the output pulse are 1543.95 nm, 1.506 nm and 33.12 nJ, respectively. Harmonic mode-locked pulses are also observed in experiments when the parameters are chosen properly. (paper)

  16. Repetition frequency scaling of an all-polarization maintaining erbium-doped mode-locked fiber laser based on carbon nanotubes saturable absorber

    Energy Technology Data Exchange (ETDEWEB)

    Sotor, J., E-mail: jaroslaw.sotor@pwr.edu.pl; Sobon, G.; Abramski, K. M. [Laser and Fiber Electronics Group, Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw (Poland); Jagiello, J.; Lipinska, L. [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland)

    2015-04-07

    We demonstrate an all-polarization maintaining (PM), mode-locked erbium (Er)-doped fiber laser based on a carbon nanotubes (CNT) saturable absorber (SA). The laser resonator was maximally simplified by using only one passive hybrid component and a pair of fiber connectors with deposited CNTs. The repetition frequency (F{sub rep}) of such a cost-effective and self-starting mode-locked laser was scaled from 54.3 MHz to 358.6 MHz. The highest F{sub rep} was obtained when the total cavity length was shortened to 57 cm. The laser allows ultrashort pulse generation with the duration ranging from 240 fs to 550 fs. Because the laser components were based on PM fibers the laser was immune to the external perturbations and generated laniary polarized light with the degree of polarization (DOP) of 98.7%.

  17. Vortex Laser based on III-V semiconductor metasurface: direct generation of coherent Laguerre-Gauss modes carrying controlled orbital angular momentum.

    Science.gov (United States)

    Seghilani, Mohamed S; Myara, Mikhael; Sellahi, Mohamed; Legratiet, Luc; Sagnes, Isabelle; Beaudoin, Grégoire; Lalanne, Philippe; Garnache, Arnaud

    2016-12-05

    The generation of a coherent state, supporting a large photon number, with controlled orbital-angular-momentum L = ħl (of charge l per photon) presents both fundamental and technological challenges: we demonstrate a surface-emitting laser, based on III-V semiconductor technology with an integrated metasurface, generating vortex-like coherent state in the Laguerre-Gauss basis. We use a first order phase perturbation to lift orbital degeneracy of wavefunctions, by introducing a weak anisotropy called here "orbital birefringence", based on a dielectric metasurface. The azimuthal symmetry breakdown and non-linear laser dynamics create "orbital gain dichroism" allowing selecting vortex handedness. This coherent photonic device was characterized and studied, experimentally and theoretically. It exhibits a low divergence (50 dB vortex purity), and single frequency operation in a stable low noise regime (0.1% rms). Such high performance laser opens the path to widespread new photonic applications.

  18. Development of laser-based techniques for identification of breached nuclear fuel elements in storage. Progress report, 1 October 1978-1 September 1979

    International Nuclear Information System (INIS)

    Anderson, R.J.; Esherick, P.

    1980-06-01

    From many possible laser-based techniques of atomic and molecular spectroscopy we have selected multiphoton ionization spectroscopy (MIS) as that one technique which best conforms to the constraints imposed by the problem of identifying breached nuclear fuel assemblies in storage. We describe experiments utilizing MIS to specifically and sensitively detect xenon (Xe) and nitric oxide (NO). We therefore experimentally demonstrate the applicability of this technique to the detection of volatile fission products leaking from breached nuclear fuel assemblies stored in water cooled basins. Even for the non-ideal circumstances of these preliminary experiments, we estimate a detection limit of 10 10 atoms/cm 3 for xenon, roughly 1% of the atmospheric content of xenon at sea level

  19. 1.5 W high efficiency and tunable single-longitudinal-mode Ho:YLF ring laser based on Faraday effect.

    Science.gov (United States)

    Wu, Jing; Ju, Youlun; Dai, Tongyu; Yao, Baoquan; Wang, Yuezhu

    2017-10-30

    We demonstrated an efficient and tunable single-longitudinal-mode Ho:YLF ring laser based on Faraday effect for application to measure atmospheric carbon dioxide (CO 2 ). Single-longitudinal-mode power at 2051.65 nm achieved 528 mW with the slope efficiency of 39.5% and the M 2 factor of 1.07, and the tunable range of about 178 GHz was obtained by inserting a Fabry-Perot (F-P) etalon with the thickness of 0.5 mm. In addition, the maximum single-longitudinal-mode power reached 1.5 W with the injected power of 528 mW at 2051.65 nm by master oscillator power amplifier (MOPA) technique. High efficiency and tunable single-longitudinal-mode based on Faraday effect around 2 μm has not been reported yet to the best of our knowledge.

  20. Smartphone Image Acquisition During Postmortem Monocular Indirect Ophthalmoscopy.

    Science.gov (United States)

    Lantz, Patrick E; Schoppe, Candace H; Thibault, Kirk L; Porter, William T

    2016-01-01

    The medical usefulness of smartphones continues to evolve as third-party applications exploit and expand on the smartphones' interface and capabilities. This technical report describes smartphone still-image capture techniques and video-sequence recording capabilities during postmortem monocular indirect ophthalmoscopy. Using these devices and techniques, practitioners can create photographic documentation of fundal findings, clinically and at autopsy, without the expense of a retinal camera. Smartphone image acquisition of fundal abnormalities can promote ophthalmological telemedicine--especially in regions or countries with limited resources--and facilitate prompt, accurate, and unbiased documentation of retinal hemorrhages in infants and young children. © 2015 American Academy of Forensic Sciences.