  1. Scattering properties of ultrafast laser-induced refractive index shaping lenticular structures in hydrogels

    Science.gov (United States)

    Wozniak, Kaitlin T.; Germer, Thomas A.; Butler, Sam C.; Brooks, Daniel R.; Huxlin, Krystel R.; Ellis, Jonathan D.

    2018-02-01

    We present measurements of light scatter induced by a new ultrafast laser technique being developed for laser refractive correction in transparent ophthalmic materials such as cornea, contact lenses, and/or intraocular lenses. In this new technique, called intra-tissue refractive index shaping (IRIS), a 405 nm femtosecond laser is focused and scanned below the corneal surface, inducing a spatially-varying refractive index change that corrects vision errors. In contrast with traditional laser correction techniques, such as laser in-situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), IRIS does not operate via photoablation, but rather changes the refractive index of transparent materials such as cornea and hydrogels. A concern with any laser eye correction technique is additional scatter induced by the process, which can adversely affect vision, especially at night. The goal of this investigation is to identify sources of scatter induced by IRIS and to mitigate possible effects on visual performance in ophthalmic applications. Preliminary light scattering measurements on patterns written into hydrogel showed four sources of scatter, differentiated by distinct behaviors: (1) scattering from scanned lines; (2) scattering from stitching errors, resulting from adjacent scanning fields not being aligned to one another; (3) diffraction from Fresnel zone discontinuities; and (4) long-period variations in the scans that created distinct diffraction peaks, likely due to inconsistent line spacing in the writing instrument. By knowing the nature of these different scattering errors, it will now be possible to modify and optimize the design of IRIS structures to mitigate potential deficits in visual performance in human clinical trials.

  2. Intra-Tissue Pressure Measurement in Ex Vivo Liver Undergoing Laser Ablation with Fiber-Optic Fabry-Perot Probe

    Directory of Open Access Journals (Sweden)

    Daniele Tosi

    2016-04-01

    Full Text Available We report the first-ever intra-tissue pressure measurement performed during 1064 nm laser ablation (LA of an ex vivo porcine liver. Pressure detection has been performed with a biocompatible, all-glass, temperature-insensitive Extrinsic Fabry-Perot Interferometry (EFPI miniature probe; the proposed methodology mimics in-vivo treatment. Four experiments have been performed, positioning the probe at different positions from the laser applicator tip (from 0.5 mm to 5 mm. Pressure levels increase during ablation time, and decrease with distance from applicator tip: the recorded peak parenchymal pressure levels range from 1.9 kPa to 71.6 kPa. Different pressure evolutions have been recorded, as pressure rises earlier in proximity of the tip. The present study is the first investigation of parenchymal pressure detection in liver undergoing LA: the successful detection of intra-tissue pressure may be a key asset for improving LA, as pressure levels have been correlated to scattered recurrences of tumors by different studies.

  3. Multiphoton tomography of intratissue tattoo nanoparticles

    Science.gov (United States)

    König, Karsten

    2012-02-01

    Most of today's intratissue tattoo pigments are unknown nanoparticles. So far, there was no real control of their use due to the absence of regulations. Some of the tattoo pigments contain carcinogenic amines e.g. azo pigment Red 22. Nowadays, the European Union starts to control the administration of tattoo pigments. There is an interest to obtain information on the intratissue distribution, their interaction with living cells and the extracellular matrix, and the mechanisms behind laser tattoo removal. Multiphoton tomographs are novel biosafety and imaging tools that can provide such information non-invasively and without further labeling. When using the spectral FLIM module, spatially-resolved emission spectra, excitation spectra, and fluorescence lifetimes can pr provided. Multiphoton tomographs are used by all major cosmetic comapanies to test the biosafety of sunscreen nanoparticles.

  4. Intelligent Planning for Laser Refractive Surgeries

    Science.gov (United States)

    Wang, Wei; Yue, Yong; Elsheikh, Ahmed; Bao, Fangjun

    2018-02-01

    Refractive error is one of leading ophthalmic diseases for both genders all over the world. Laser refractive correction surgery, e.g., laser in-situ keratomileusis (LASIK), has been commonly used worldwide. The prediction of surgical parameters, e.g., corneal ablation depth, depends on the doctor’s experience, theoretical formula and surgery reference manual in the preoperative diagnosis. The error of prediction may present a potential surgical risk and complication. Being aware of the surgery parameters is important because these can be used to estimate a patient’s post-operative visual quality and help the surgeon plan a suitable treatment. Therefore, in this paper we discuss data mining techniques that can be utilized for the prediction of laser refractive correction surgery parameters. It can provide the surgeon with a reference for possible surgical parameters and outcomes of the patient before the laser refractive correction surgery.

  5. Refractive regression after laser in situ keratomileusis.

    Science.gov (United States)

    Yan, Mabel K; Chang, John Sm; Chan, Tommy Cy

    2018-04-26

    Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed. © 2018 Royal Australian and New Zealand College of Ophthalmologists.

  6. Anterior segment surgery IOLs, lasers, and refractive keratoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Stark, W.J.; Terry, A.C.; Maumenee, A.E.

    1987-01-01

    The contributors to this text combine their expertise to make this book available on intraocular lenses, refractive corneal surgery, and the use of the YAG laser. Included is information on; IOL power calculations; the use of the YAG laser; retinal damage by short wavelength light; reviews of corneal refractive surgery; possibilities for the medical prevention of cataracts; and more.

  7. Index of Refraction Measurements Using a Laser Distance Meter

    Science.gov (United States)

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  8. Engineering of refractive index in sulfide chalcogenide glass by direct laser writing

    KAUST Repository

    Zhang, Yaping

    2010-01-01

    Arsenic trisulfide (As2S3) glass is an interesting material for photonic integrated circuits (PICs) as infrared (IR) or nonlinear optical components. In this paper, direct laser writing was applied to engineer the refractive index of As2S3 thin film. Film samples were exposed to focused above bandgap light with wavelength at 405 nm using different fluence adjusted by laser power and exposure time. The index of refraction before and after laser irradiation was calculated by fitting the experimental data obtained from Spectroscopic Ellipsometer (SE) measurement to Tauc-Lorenz dispersion formula. A positive change in refractive index (Δn = 0.19 at 1.55 μm) as well as an enhancement in anisotropy was achieved in As2S3 film by using 10 mW, 0.3 μs laser irradiation. With further increasing the fluence, refractive index increased while anisotropic property weakened. Due to the rapid and large photo-induced modification of refractive index obtainable with high spatial resolution, this process is promising for integrated optic device fabrication.

  9. About the correctness of laser refractive surgery in children

    Directory of Open Access Journals (Sweden)

    V. V. Kurenkov

    2016-01-01

    Full Text Available Disturbances of refraction are one of the most urgent problems of pediatric ophthalmology. Late and incomplete correction of refractive errors leads to the development of amblyopia, disturbances of binocular vision, the appearance of strabismus. Such complications reduce the quality of life, drastically limit the choice of professional child. Pediatric Ophthalmology always face a choice: many drugs and technologies are not approved for use in pediatric patients, practitioners are forced to use their «off-label», but such situations require great care and strict medical indications. For example, refractive surgery has worked well in adults, but its use remains controversial in children for security reasons and unpredictable effects. Several authors have described the use of laser refractive surgery in children under the age of 18 years, but there are no results of a multicenter, controlled study evaluating the safety, efficacy, and especially long-term results. In all the studies, the calculation was performed on adult nomograms ablation, while not proved how they are accurate for children. Long-term results and data on the endothelial cell density, corneal curvature changes in catamnesis are presented no longer than two years. Despite the fact that currently there is insufficient information about the results of remote application keratorefractive laser surgery in children, and there are no indication system and contraindications, modern achievements in medicine should be used in pediatric patients, and our successful track record proves it clearly. Undoubtedly, the positive experience of the laser surgery use in a child with clouding of the cornea in the outcome of herpetic keratitis, which provided a positive result: high visual acuity, binocular vision and lack of infection relapses for 2 years, requires study, evidence multicenter studies, and possibly expansion of indications for refractive laser surgery.

  10. Change in refractive index of muscle tissue during laser-induced interstitial thermotherapy.

    Science.gov (United States)

    Chen, Na; Chen, Meimei; Liu, Shupeng; Guo, Qiang; Chen, Zhenyi; Wang, Tingyun

    2014-01-01

    This paper presents a long-period fiber-grating (LPG) based Michelson interferometric refractometry to monitor the change in refractive index of porcine muscle during laser-induced interstitial thermotherapy (LITT). As the wavelength of RI interferometer alters with the change in refractive index around the probe, the LPG based refractometry is combined with LITT system to measure the change in refractive index of porcine muscle when irradiated by laser. The experimental results show the denaturation of tissue alters the refractive index significantly and the LPG sensor can be applied to monitor the tissue state during the LITT.

  11. Assessment of dose load of personnel in intratissue gamma beam therapy

    International Nuclear Information System (INIS)

    Stavitskij, R.V.; Zamyatin, O.A.; Varennikov, O.I.; Astakhova, I.V.

    1995-01-01

    Suggest a method for retrospective assessment of levels of irradiation of small groups of personnel exposed to radiation sources. Presents estimated values of cumulative and local doses obtained by personnel during intratissue gamma beam therapy carried out by manual consecutive injections of intrastats and irradiation sources. 3 refs.; 5 tabs

  12. Laser photo-reflectance characterization of resonant nonlinear electro-refraction in thin semiconductor films

    International Nuclear Information System (INIS)

    Chism, Will; Cartwright, Jason

    2012-01-01

    Photo-reflectance (PR) measurements provide a non-contact means for the precise characterization of semiconductor electronic properties. In this paper, we investigate the use of a laser beam as the probe beam in the PR setup. In this case it is seen that the nonlinear refraction is responsible for the amplitude change of the reflected probe field, whereas the phase change is due to nonlinear absorption. The open aperture condition may then be used to eliminate the spatial phase at the detector, thereby isolating the electro-refractive contribution to the PR signal. This greatly simplifies the PR analysis and allows absolute measurements of electro-refraction in thin semiconductor films. We report the application of the laser PR technique to characterize physical strain in thin silicon on silicon-germanium films. - Highlights: ► We describe the theory of laser photoreflectance. ► Laser photoreflectance is used to independently characterize nonlinear refraction. ► We report the characterization of strain in thin strained silicon films.

  13. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    Science.gov (United States)

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  14. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    Science.gov (United States)

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  15. X-ray refractive index of laser-dressed atoms

    OpenAIRE

    Buth, Christian; Santra, Robin

    2008-01-01

    We investigated the complex index of refraction in the x-ray regime of atoms in laser light. The laser (intensity up to 10^13 W/cm^2, wavelength 800nm) modifies the atomic states but, by assumption, does not excite or ionize the atoms in their electronic ground state. Using quantum electrodynamics, we devise an ab initio theory to calculate the dynamic dipole polarizability and the photoabsorption cross section, which are subsequently used to determine the real and imaginary part, respectivel...

  16. Effectiveness of the Intratissue Percutaneous Electrolysis (EPI®) technique and isoinertial eccentric exercise in the treatment of patellar tendinopathy at two years follow-up.

    Science.gov (United States)

    Abat, Ferran; Diesel, Wayne-J; Gelber, Pablo-E; Polidori, Fernando; Monllau, Joan-Carles; Sanchez-Ibañez, Jose-Manuel

    2014-04-01

    to show the effect of Intratissue Percutaneous Electrolysis (EPI®) combined with eccentric programme in the treatment of patellar tendinopathy. prospective study of 33 athlete-patients consecutively treated for insertional tendinopathy with Intratissue Percutaneous Electrolysis (EPI®) and followed for 2 years. Functional assessment was performed at the first visit, at three months and two years with the Tegner scale and VISA-P. an average improvement in the VISA-P of 35 points was obtained. The mean duration of treatment was 4.5 weeks. Some 78.8% of the patients returned to the same level of physical activity as before the injury by the end of treatment, reaching 100% at two years. intratissue percutaneous electrolysis (EPI®) combined with an eccentric-based rehab program offers excellent results in terms of the clinical and functional improvement of the patellar tendon with low morbidity in a short-term period. Therapy, level 4.

  17. Quantitative study of the ionization-induced refraction of picosecond laser pulses in gas-jet targets

    International Nuclear Information System (INIS)

    Mackinnon, A.J.; Borghesi, M.; Iwase, A.; Jones, M.W.; Pert, G.J.; Rae, S.; Burnett, K.; Willi, O.

    1996-01-01

    A quantitative study of refractive whole beam defocusing and small scale breakup induced by optical ionization of subpicosecond and picosecond, 0.25 and 1 μm, laser pulses in gas-jet targets at densities above 1x10 19 cm -3 has been carried out. A significant reduction of the incident laser intensity was observed due to refraction from ionization-induced density gradients. The level of refraction measured with optical probing correlated well with the fraction of energy transmitted through the plasma. The numerical and analytical models were found to agree well with experimental observations. copyright 1996 The American Physical Society

  18. Computed estimation of visual acuity after laser refractive keratectomy

    Science.gov (United States)

    Rol, Pascal O.; Parel, Jean-Marie A.; Hanna, Khalil

    1991-06-01

    A number of surgical techniques has been developed to correct ametropia (refractive defaults) of the eye by changing the anterior corneal radius. Because the air-cornea interface makes up for about two-third of the refractive power of the eye, a refractive correction is obtained by a suitable photoablation of the cornea. For this purpose, e.g., an ArF excimer laser which emits a wavelength of 193 nm is being used. After a mechanical removal of the epithelium, the Bowman's layer and the corneal stroma are photoablated on typically 50% of the central surface of the cornea with various precomputed shapes. Methods using a variable diaphragm1 or a scanning slit2 are being utilized. After regrowth of the epithelium, a smooth interface with air develops itself, which can be attributed to a mechanical equilibration. Yet, SEM studies have shown that with such kind of treatments, irregularities can remain in the new stromal surface (Fig. 1). A possible explanation for this effect is associated with an inhomogeneous energy distribution of the laser beam profile3. To some extent, the stromal surface is equalized by the epithelial layer during healing& However, as the corneal epithelium and stroma have different refractive indices, a scatter of the incident light may result causing a haze in the cornea and a blur of the image at the retina. In such a case the resolution and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the deformation observed at the epithelium-stroma interface.

  19. Frequency stabilization of a He-Ne gas laser by controlling refractive index of laser plasma

    International Nuclear Information System (INIS)

    Xie Yi; Wu Yizun

    1991-01-01

    A new way to stabilize the frequency of a Zeeman He-Ne gas laser is described. The laser frequency is stabilized by controlling the refractive index of the laser plasma. It does not need a gas laser tube with a piezoelectric ceramic (PZT) made by special technology. As the phase-locking technology is used in the laser servo system, the self-beat frequency is a constant and the frequency stability is better than 2.2 x 10 -11 (averaging time = 10 sec.). The long term frequency fluctuation never exceeded 2 x 10 -8 during two months. The frequency of the locked point can be adjusted continuously in the range of over 200 MHz

  20. High refractive index modification of SiO2 created by femtosecond laser nanostructuring

    International Nuclear Information System (INIS)

    Barillot, T; Grojo, D; Gertsvolf, M; Rayner, D M; Corkum, P B; Lei, S

    2010-01-01

    By comparing simulations with experiment, we show that the effective refractive index of fused SiO 2 can be locally reduced by (1.8 ± 0.2)% by femtosecond laser nanostructuring. We create a microlens of material containing a planar array of nanocracks embedded inside fused silica and probe how it refracts or absorbs light as a function of pulse energy. The self-generated microlens lowers the peak light intensity by deflecting the light around the focus. We obtain the refractive index by simulating the beam transport using the 3D wave equation in conjunction with the measured dimensions of the modified material.

  1. [ISO 9001-2000 certification for refractive laser treatment].

    Science.gov (United States)

    Lebuisson, D A; Arson, B; Abenhaïm, A; Albou-Ganem, C; Assouline, M; Chong Sit, D; Danan, A; Montefiore, G; Montin, J-F; Nguyen-Khoa, J-L; Pietrini, D; Saragoussi, J-J; Trong, Th; Amar, R

    2005-05-01

    To obtain ISO 9001-2000 certification for laser corneal refractive treatment, never before sought in Europe. The consulting firm Veritas led the certification process with the clinic's staff manager. This ISO norm is dedicated to the implementation of a quality management system. We assessed and optimized all necessary resources, evaluating customer satisfaction using patient and referring-physician surveys. We started quality rounds including surgeons, nurses, and technicians. Based on this preparation, we redefined and explained all processes including staff responsibilities and necessary resources in the quality manual. The procedure lasted 14 months with substantial involvement on the part of the management. Unconditional ISO 9001-2000 certification was granted by the independent audit firm, BVQI, in december 2003 for refractive laser treatment. The 2000 version of the new ISO 9001-2000 seeks to meet the demand for improving health care delivery in this field, most particularly by establishing a clear procedural orientation. Such certification enhances team work, stabilizes methodologies, and reinforces cohesion and self-audit. Patients notice that the center follows a consistent quality policy and are assured that the clinic respects rules and regulations. Certification is an advantageous alternative when accreditation cannot be considered. Our article discusses the steps taken in upper management, quality management, procedural guidance, as well as customer and staff counselling. It also discusses the project's cost/benefit ratio for the organization.

  2. Refractive microlenses produced by excimer laser machining of poly(methyl methacrylate)

    DEFF Research Database (Denmark)

    Jensen, Martin Frøhling; Krühne, Ulrich; H., L.

    2005-01-01

    A method has been developed whereby refractive microlenses can be produced in poly (methyl methacrylate) by excimer laser irradiation at λ = 248 nm. The lenses are formed by a combined photochemical and thermal process. The lenses are formed as depressions in the substrate material (negative foca...

  3. Linear self-focusing of continuous UV laser beam in photo-thermo-refractive glasses.

    Science.gov (United States)

    Sidorov, Alexander I; Gorbyak, Veronika V; Nikonorov, Nikolay V

    2018-03-19

    The experimental and theoretical study of continuous UV laser beam propagation through thick silver-containing photo-thermo-refractive glass is presented. It is shown for the first time that self-action of UV Gaussian beam in glass results in its self-focusing. The observed linear effect is non-reversible and is caused by the transformation of subnanosized charged silver molecular clusters to neutral state under UV laser radiation. Such transformation is accompanied by the increase of molecular clusters polarizability and the refractive index increase in irradiated area. As a result, an extended positive lens is formed in glass bulk. In a theoretical study of linear self-focusing effect, the "aberration-free" approximation was used, taking into account spatial distribution of induced absorption.

  4. Preliminary observation of refractive cataract surgery assisted by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Xiao-Li Wang

    2015-12-01

    Full Text Available AIM:To compare the differences of visual acuity and corneal astigmatism postoperatively between conventional refractive cataract surgery and that assisted by femtosecond laser.METHODS:Sixty patients(60 eyeswith age-related cataract and cornea astigmatism were divided into femtosecond group and conventional group randomly or voluntarily. The flat shaft, steep shaft and diopter of corneal astigmatism in patients in femtosecond group were inputted into the online vector calculators to get the location and width of the incision. Then femtosecond laser was used to make corneal releasing incision, the main and auxiliary incision. Phacoemulsification and aspheric multifocal intraocular lens implantation were undergone. Patients in conventional group received full-thickness relaxing incision by cornea paracentesis knife at the steepest meridian axis during phacoemulsification. Then aspheric multifocal intraocular lenses were implanted. Uncorrected distance visual acuity(UCDVA, uncorrected near visual acuity(UCNVAand cornea astigmatism were observed at 1d,1wk and 1mo postoperative. RESULTS:UCVA of patients in both groups was improved after the surgeries. UCDVA and UCNVA of femtosecond group were higher than those of conventional group, while the cornea astigmatism of femtosecond group was lower than that of conventional group.CONCLUSION:Refractile cataract surgery assisted by femtosecond laser canoffer better visual quality than conventional refractive cataract surgery because of lower cornea astigmatism and better visual acuity.

  5. High slope efficiency and high refractive index change in direct-written Yb-doped waveguide lasers with depressed claddings.

    Science.gov (United States)

    Palmer, Guido; Gross, Simon; Fuerbach, Alexander; Lancaster, David G; Withford, Michael J

    2013-07-15

    We report the first Yb:ZBLAN and Yb:IOG10 waveguide lasers fabricated by the fs-laser direct-writing technique. Pulses from a Titanium-Sapphire laser oscillator with 5.1 MHz repetition rate were utilized to generate negative refractive index modifications in both glasses. Multiple modifications were aligned in a depressed cladding geometry to create a waveguide. For Yb:ZBLAN we demonstrate high laser slope efficiency of 84% with a maximum output power of 170 mW. By using Yb:IOG10 a laser performance of 25% slope efficiency and 72 mW output power was achieved and we measured a remarkably high refractive index change exceeding Δn = 2.3 × 10(-2).

  6. Modal study of refractive effects on x-ray laser coherence

    International Nuclear Information System (INIS)

    Amendt, P.; London, R.A.; Strauss, M.

    1991-01-01

    The role of smoothly varying transverse gain and refraction profiles on x-ray laser intensity and coherence is analyzed by modally expanding the electric field within the paraxial approximation. Comparison with a square transverse profile reveals that smooth-edged profiles lead to: (1) a greatly reduced number of guided modes, (2) the continued cancellation of local intensity from a loosely guided mode by resonant free modes, (3) and the absence of extraneous (or anomalous) free mode resonances. These generic spectral properties should enable a considerable simplification in analyzing and optimizing the coherence properties of laboratory soft x-ray lasers. 6 refs., 3 figs

  7. Determination of femtosecond-laser-induced refractive-index changes in an optical fiber from far-field measurements

    DEFF Research Database (Denmark)

    Savolainen, Juha-Matti; Grüner-Nielsen, Lars; Kristensen, Poul

    2014-01-01

    A new method for direct writing of localized, circularly symmetric refractive-index changes in optical fibers with a femtosecond laser is demonstrated. The refractive-index changes are characterized using a novel approach employing comparison of numerical simulations to the measured far......-field profiles of unmodified and modified fibers. From the analysis, a negative refractive-index change of −0.015 0.005 within a radius of 0.6 0.1 μm is determined....

  8. Engineering of refractive index in sulfide chalcogenide glass by direct laser writing

    KAUST Repository

    Zhang, Yaping; Gao, Yangqin; Ng, Tien Khee; Ooi, Boon S.; Chew, Basil; Hedhili, Mohamed N.; Zhao, Donghui; Jain, Himanshu

    2010-01-01

    Arsenic trisulfide (As2S3) glass is an interesting material for photonic integrated circuits (PICs) as infrared (IR) or nonlinear optical components. In this paper, direct laser writing was applied to engineer the refractive index of As2S3 thin film

  9. Past and present of corneal refractive surgery

    DEFF Research Database (Denmark)

    Vestergaard, Anders Højslet

    Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become...

  10. Highly sensitive refractive index fiber inline Mach-Zehnder interferometer fabricated by femtosecond laser micromachining and chemical etching

    Science.gov (United States)

    Sun, Xiao-Yan; Chu, Dong-Kai; Dong, Xin-Ran; Zhou, Chu; Li, Hai-Tao; Luo-Zhi; Hu, You-Wang; Zhou, Jian-Ying; Cong-Wang; Duan, Ji-An

    2016-03-01

    A High sensitive refractive index (RI) sensor based on Mach-Zehnder interferometer (MZI) in a conventional single-mode optical fiber is proposed, which is fabricated by femtosecond laser transversal-scanning inscription method and chemical etching. A rectangular cavity structure is formed in part of fiber core and cladding interface. The MZI sensor shows excellent refractive index sensitivity and linearity, which exhibits an extremely high RI sensitivity of -17197 nm/RIU (refractive index unit) with the linearity of 0.9996 within the refractive index range of 1.3371-1.3407. The experimental results are consistent with theoretical analysis.

  11. The effect of humidity and temperature on visual outcomes after myopic corneal laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Hood CT

    2016-11-01

    Full Text Available Christopher T Hood,1 Roni M Shtein,1 Daniel Veldheer,1,2 Munira Hussain,1 Leslie M Niziol,1 David C Musch,1,3 Shahzad I Mian1 1Department of Ophthalmology and Visual Sciences, University of Michigan W.K. Kellogg Eye Center, Ann Arbor, MI, 2Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, WI, 3Department of Epidemiology, University of Michigan, Ann Arbor, MI, USA Objective: To determine whether procedure room environmental conditions are associated with outcomes after myopic laser in situ keratomileusis (LASIK or laser-assisted keratomileusis (LASEK. Design: Retrospective chart review. Participants: Eight hundred sixty-three eyes of 458 consecutive patients at a university-based academic practice. Methods: We reviewed the medical records of consecutive patients who underwent LASIK or LASEK over a 3-year period. Linear mixed regression models were used to investigate the association of laser room temperature and humidity with the outcomes of visual acuity and postoperative manifest spherical equivalent refraction. Repeated measures logistic regression models were used for the outcomes of diffuse lamellar keratitis (DLK and need for enhancement surgery. Results: Subjects were on an average 38.6 years old at the time of surgery (standard deviation [SD] =10.3 and the average spherical equivalent refraction of eyes was 3.8 diopters (SD =2.03. Regression models did not reveal a significant association between temperature and uncorrected distance visual acuity (UDVA or corrected distance visual acuity (CDVA, or between humidity and UDVA (P>0.05 for all. However, increased humidity was associated with a small but statistically significant improvement in CDVA after LASIK at 1 day, 1 month, 3 months, and 1 year postoperatively (P<0.05 for all. There was no significant association between temperature and humidity and the need for enhancement, the incidence of DLK, or postoperative manifest refraction. Conclusion: While increased laser

  12. High-precision diode-laser-based temperature measurement for air refractive index compensation

    International Nuclear Information System (INIS)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppae, Jeremias; Lassila, Antti

    2011-01-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

  13. Correction of refractive errors

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2005-10-01

    Full Text Available Background: Spectacles and contact lenses are the most frequently used, the safest and the cheapest way to correct refractive errors. The development of keratorefractive surgery has brought new opportunities for correction of refractive errors in patients who have the need to be less dependent of spectacles or contact lenses. Until recently, RK was the most commonly performed refractive procedure for nearsighted patients.Conclusions: The introduction of excimer laser in refractive surgery has given the new opportunities of remodelling the cornea. The laser energy can be delivered on the stromal surface like in PRK or deeper on the corneal stroma by means of lamellar surgery. In LASIK flap is created with microkeratome in LASEK with ethanol and in epi-LASIK the ultra thin flap is created mechanically.

  14. Estimated refractive index and solid density of DT, with application to hollow-microsphere laser targets

    International Nuclear Information System (INIS)

    Briggs, C.K.; Tsugawa, R.T.; Hendricks, C.D.; Souers, P.C.

    1975-01-01

    The literature values for the 0.55-μm refractive index N of liquid and gaseous H 2 and D 2 are combined to yield the equation (N - 1) = [(3.15 +- 0.12) x 10 -6 ]rho, where rho is the density in moles per cubic meter. This equation can be extrapolated to 300 0 K for use on DT in solid, liquid, and gas phases. The equation is based on a review of solid-hydrogen densities measured in bulk and also by diffraction methods. By extrapolation, the estimated densities and 0.55-μm refractive indices for DT are given. Radiation-induced point defects could possibly cause optical absorption and a resulting increased refractive index in solid DT and T 2 . The effect of the DT refractive index in measuring glass and cryogenic DT laser targets is also described

  15. Visual and refractive outcomes following myopic laser-assisted subepithelial keratectomy with a flying-spot excimer laser.

    Science.gov (United States)

    McAlinden, Colm; Skiadaresi, Eirini; Moore, Jonathan E

    2011-05-01

    To investigate the visual and refractive outcomes following laser-assisted subepithelial keratectomy (LASEK) surgery with a flying-spot excimer laser. Private practice, Ireland. Case series. In this prospective study, the mean manifest spherical equivalent (SE), sphere, and cylinder were measured preoperatively. All eyes had LASEK surgery with an aberration-free algorithm with the Schwind Amaris excimer laser. Outcomes measured at 1 month, 6 months, and 1 year were uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity, contrast sensitivity, aberrometry, and complications. Accuracy, efficacy, and safety were evaluated at 1 year. Preoperatively, the mean SE, sphere, and cylinder in the 80 eyes (48 patients) were -3.58 diopters (D) ± 2.00 (SD), -3.23 ± 1.93 D, and -0.85 ± 0.65 D, respectively. One year postoperatively, the mean SE was -0.00 ± 0.22 D; 57 eyes (71%) were within -0.13 to +0.13 D of the SE, and 71 eyes (98%) were within ±0.50 D. The mean UDVA was -0.06 ± 0.07 logMAR, with an efficacy index of 1.04. The postoperative SE was stable between 1 month, 3 months, and 1 year. One eye (1%) had a change in SE by more than 0.50 D at 6 months and 1 year. There were no statistically significant differences in any aberrations at 1 year. The contrast sensitivity improved from 1.66 ± 0.17 log units preoperatively to 1.72 ± 0.15 log units at 1 month postoperatively (P=.0003), which was unchanged at 6 months and 1 year. This study demonstrated the effectiveness of LASEK for the treatment of myopia with this flying-spot excimer laser. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. High-precision diode-laser-based temperature measurement for air refractive index compensation.

    Science.gov (United States)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppä, Jeremias; Lassila, Antti

    2011-11-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement. © 2011 Optical Society of America

  17. Macroeconomic landscape of refractive surgery in the United States.

    Science.gov (United States)

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  18. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    Energy Technology Data Exchange (ETDEWEB)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I. [General Physics Institute of Russian Academy of Sciences, Moscow (Russian Federation); National Research Nuclear University ' ' MEPhI' ' , Moscow (Russian Federation); Polikarpov, M.; Ershov, P. [Immanuel Kant Baltic Federal University, Functional Nanomaterials, Kaliningrad (Russian Federation); Kuznetsov, S.; Yunkin, V. [Institute of Microelectronics Technology RAS, Chernogolovka, Moscow region (Russian Federation); Snigireva, I. [European Synchrotron Radiation Facility, Grenoble (France)

    2016-03-15

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  19. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    International Nuclear Information System (INIS)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I.; Polikarpov, M.; Ershov, P.; Kuznetsov, S.; Yunkin, V.; Snigireva, I.

    2016-01-01

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  20. TE modes of UV-laser generated waveguides in a planar polymer chip of parabolic refractive index profile

    Science.gov (United States)

    Shams El-Din, M. A.

    2018-04-01

    The UV-laser lithographic method is used for the preparation of Polymeric integrated-optical waveguides in a planar polymer chip. The waveguide samples are irradiated by an excimer laser of wavelength 248 nm with different doses and with the same fluencies. The refractive index depth profile for the waveguides, in the first zone is found to have a parabolic shape and Gaussian shape in the second one that can be determined by Mach-Zehnder interferometer. Both the mode field distribution and the effective mode indices for the first zone only are determined by making use of the theoretical mode and the experimental data. It is found that the model field distribution is strongly dependent on the refractive indices for each zone.

  1. Fabrication Quality Analysis of a Fiber Optic Refractive Index Sensor Created by CO2 Laser Machining

    Directory of Open Access Journals (Sweden)

    Wei-Te Wu

    2013-03-01

    Full Text Available This study investigates the CO2 laser-stripped partial cladding of silica-based optic fibers with a core diameter of 400 μm, which enables them to sense the refractive index of the surrounding environment. However, inappropriate treatments during the machining process can generate a number of defects in the optic fiber sensors. Therefore, the quality of optic fiber sensors fabricated using CO2 laser machining must be analyzed. The results show that analysis of the fiber core size after machining can provide preliminary defect detection, and qualitative analysis of the optical transmission defects can be used to identify imperfections that are difficult to observe through size analysis. To more precisely and quantitatively detect fabrication defects, we included a tensile test and numerical aperture measurements in this study. After a series of quality inspections, we proposed improvements to the existing CO2 laser machining parameters, namely, a vertical scanning pathway, 4 W of power, and a feed rate of 9.45 cm/s. Using these improved parameters, we created optical fiber sensors with a core diameter of approximately 400 μm, no obvious optical transmission defects, a numerical aperture of 0.52 ± 0.019, a 0.886 Weibull modulus, and a 1.186 Weibull-shaped parameter. Finally, we used the optical fiber sensor fabricated using the improved parameters to measure the refractive indices of various solutions. The results show that a refractive-index resolution of 1.8 × 10−4 RIU (linear fitting R2 = 0.954 was achieved for sucrose solutions with refractive indices ranging between 1.333 and 1.383. We also adopted the particle plasmon resonance sensing scheme using the fabricated optical fibers. The results provided additional information, specifically, a superior sensor resolution of 5.73 × 10−5 RIU, and greater linearity at R2 = 0.999.

  2. Cascade conical refraction for annular pumping of a vortex Nd:YAG laser and selective excitation of low- and high-order Laguerre–Gaussian modes

    Science.gov (United States)

    Wu, Yongxiao; Wang, Zhongyang; Chen, Sanbin; Shirakwa, Akira; Ueda, Ken-ichi; Li, Jianlang

    2018-05-01

    We proposed an efficient and vortex Nd:YAG laser for selective lasing of low- and high-order vortex modes, in which multiple-ring pump light was originated from cascaded conical refraction of multiple biaxial crystals. In our proof of concept demonstration, we used two-crystal cascade conical refraction to generate two-ring pump light; the mutual intensity ratio and relative separation of the inner ring and outer ring were controlled by rotating the second biaxial crystal and by moving the imaging lens, respectively. As a result, we obtained selective excitation of Laguerre–Gaussian (LG01 and LG03) vortex modes in the end-pump Nd:YAG laser. For LG01-mode output, the laser power reached 439 mW with 52.5% slope efficiency; for LG03-mode output, the laser power reached 160 mW with 41.3% slope efficiency. Our results revealed that the multiple-ring pumping technique based on cascaded conical refraction would pave the way for realization of the efficient and switchable excitation of low- and high-order LG modes in an end-pumped solid-state laser.

  3. The effect of refractive index changes in an intracavity absorption on the laser output power

    International Nuclear Information System (INIS)

    Al-Hawat, Sh.; Eskef, M.

    2007-10-01

    A model describing the intra-cavity absorption has been developed. The model allows for a reliable description of the attenuation of laser power as a function of the gas pressure inside the absorption cell, conducting both real and imaginary parts of the refractive index of the absorbing gas. The model relies on an adequate integration of the additional loss due to the absorption into the rate equations. After that the rate equations are solved under steady state conditions, which is quite reliable for a cw CO 2 laser. The oscillation, clearly observed in case of weak absorption, is described in the framework of an interference model considering the electric field inside the cavity as the interference result of successive phase correlated waves differing from each other in the number of passes made through the cavity. The phase shift is determined by the optical length of the cavity depending on the real part of the refractive index of the gas in the absorption cell. The model has been applied to analyze a large set of attenuation curves obtained in a previous work, in which intra-cavity absorption was measured for the three gases CFC-11, 12, 22 using a tunable cw CO 2 laser at 44 lines of the emission spectrum of the CO 2 molecule distributed on the branches P and R of the two bands at 9.6 μm and 10.6 μm. For mostly all examples, the value of the absorption cross section (imaginary part of the refractive index) has been determined by fitting the model to the experimental data. Furthermore, the value of the linear polarizability (real part of the refractive index) has been calculated from the oscillation period for all examples, in which the attenuation curve exhibits reliable oscillating behavior. The results are in fair agreement with the values of the absorption cross section published in the Hitran data base, as well as with the results obtained from independent absorption measurements performed outside the cavity (Author)

  4. The business of refractive laser assisted cataract surgery (ReLACS).

    Science.gov (United States)

    Berdahl, John P; Jensen, Matthew P

    2014-01-01

    Refractive Laser Assisted Cataract Surgery (ReLACS) combines the femtosecond laser with other noncovered tests and services in an attempt to reduce spectacle dependence in combination with cataract surgery. Significant interest is present among ophthalmologists who are considering adopting this technology, however significant capital outlays and continuing expenses can make the decision to adopt ReLACS foreboding. We review the financial considerations of ReLACS and review the trends seen in early adopters of this technology. Recent findings have shown that ReLACS is a growing segment of cataract surgery. Most practices who have implemented the technology have broken even and have a positive outlook on the financial return of implementing the ReLACS program. The average break-even analysis point for practices is around 230 cases a year. ReLACS is growing and appears to be a financial viable approach for many practices.

  5. Large-acceptance diamond planar refractive lenses manufactured by laser cutting.

    Science.gov (United States)

    Polikarpov, Maxim; Snigireva, Irina; Morse, John; Yunkin, Vyacheslav; Kuznetsov, Sergey; Snigirev, Anatoly

    2015-01-01

    For the first time, single-crystal diamond planar refractive lenses have been fabricated by laser micromachining in 300 µm-thick diamond plates which were grown by chemical vapour deposition. Linear lenses with apertures up to 1 mm and parabola apex radii up to 500 µm were manufactured and tested at the ESRF ID06 beamline. The large acceptance of these lenses allows them to be used as beam-conditioning elements. Owing to the unsurpassed thermal properties of single-crystal diamond, these lenses should be suitable to withstand the extreme flux densities expected at the planned fourth-generation X-ray sources.

  6. Lasing characteristics of refractive-index-matched composite Y3Al5O12 rods employing transparent ceramics for solar-pumped lasers

    Science.gov (United States)

    Hasegawa, Kazuo; Ichikawa, Tadashi; Takeda, Yasuhiko; Ikesue, Akio; Ito, Hiroshi; Motohiro, Tomoyoshi

    2018-04-01

    We have proposed a new configuration of solar-pumped lasers employing transparent ceramic rods. The laser rod has a composite structure consisting of a Nd/Cr:YAG gain domain surrounded by Gd:YAG with the same refractive index as that of Nd/Cr:YAG. The lasing mode is well controlled by the output coupler, and the parasitic oscillation is suppressed, owing to the refractive index matching. A high laser slope efficiency and a low laser oscillation threshold were achieved owing to the suppressed absorption outside the lasing mode, which was previously a serious issue for the end-pumping configuration using a high-NA focusing optics. The laser oscillation threshold of 136 mW and the slope efficiency of 25.3% were derived. Thus, we have resolved the issue of useless absorption associated with the high-NA end-pumping, and achieved significant improvements compared with the conventional structure of uniform Nd/Cr:YAG.

  7. Visual and refractive outcomes of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-q excimer lasers: a prospective, contralateral study.

    Science.gov (United States)

    Mearza, Ali A; Muhtaseb, Mohammed; Aslanides, Ioannis M

    2008-11-01

    To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.

  8. Refractive surgery trends and practice style changes in Germany over a 3-year period.

    Science.gov (United States)

    Schmack, Ingo; Auffarth, Gerd U; Epstein, Daniel; Holzer, Mike P

    2010-03-01

    To study the current practice styles and preferences of refractive surgeons in Germany. In February 2008, a seven-item questionnaire regarding the practice of refractive surgery was mailed to 282 members of the German Society of Intra-ocular Lens Implantation, Interventional, and Refractive Surgery (DGII) and the Commission of Refractive Surgery (KRC). Most questions were identical to our 2005 German refractive surgery survey. All data were analyzed in a masked fashion. The response rate was 42.2%. The majority (68%) of respondents reported that they perform refractive surgery in laser centers (exclusively or partially) followed by general hospitals (19.4%) and universities (12.6%). Although LASIK was the predominant type of refractive surgery performed (80.6%), other refractive procedures included refractive lens exchange (60.2%), photorefractive keratectomy (47.6%), phakic intraocular lens implants (45.6%), laser-assisted subepithelial keratectomy (36.9%), epithelial laser in situ keratomileusis (15.5%), intracorneal rings (5.8%), and limbal relaxing incisions (2.9%). The volume of refractive surgery procedures and the preferred type of excimer laser systems, microkeratomes, and diagnostic devices varied at different institutions. Most respondents performed either wavefront-guided custom ablation or wavefront-optimized ablation (63.1%) compared with conventional excimer laser correction (36.9%). Refractive surgery practice styles and preferences in Germany are comparable to trends in other European countries. Although LASIK is the most commonly performed refractive procedure, the numbers of various surface ablation techniques and refractive intraocular lens procedures are increasing. Copyright 2010, SLACK Incorporated.

  9. Optical Nonlinear Refractive Index of Laser-Ablated Gold Nanoparticles Graphene Oxide Composite

    Directory of Open Access Journals (Sweden)

    Amir Reza Sadrolhosseini

    2014-01-01

    Full Text Available Gold nanoparticles were prepared in graphene oxide using laser ablation technique. The ablation times were varied from 10 to 40 minutes, and the particle size was decreased from 16.55 nm to 5.18 nm in spherical shape. The nanoparticles were capped with carboxyl and the hydroxyl groups were obtained from Fourier transform infrared spectroscopy. Furthermore, the UV-visible peak shifted with decreasing of nanoparticles size, appearing from 528 nm to 510 nm. The Z-scan technique was used to measure the nonlinear refractive indices of graphene oxide with different concentrations and a gold nanoparticle graphene oxide nanocomposite. Consequently, the optical nonlinear refractive indices of graphene oxide and gold nanoparticle graphene oxide nanocomposite were shifted from 1.63×10-9 cm2/W to 4.1×10-9 cm2/W and from 1.85×10-9 cm2/W to 5.8×10-9 cm2/W, respectively.

  10. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  11. The use of erbium fiber laser relaxation frequency for sensing refractive index and solute concentration of aqueous solutions

    International Nuclear Information System (INIS)

    Arellano-Sotelo, H; Barmenkov, Yu O; Kir'yanov, A V

    2008-01-01

    We report a novel-principle fiber-laser intra-cavity sensor for measuring refractive index and solute concentration of aqueous solutions. The sensor operation is based on a variation of the laser oscillation relaxation frequency (the measured parameter), sensitive to the intra-cavity loss change. The sensor capacity is demonstrated on the example of measurements of sugar concentration in water. A modeling of the sensor operation is presented, allowing its performance optimization

  12. Refractive index modulation of Sb70Te30 phase-change thin films by multiple femtosecond laser pulses

    International Nuclear Information System (INIS)

    Lei, Kai; Wang, Yang; Jiang, Minghui; Wu, Yiqun

    2016-01-01

    In this study, the controllable effective refractive index modulation of Sb 70 Te 30 phase-change thin films between amorphous and crystalline states was achieved experimentally by multiple femtosecond laser pulses. The modulation mechanism was analyzed comprehensively by a spectral ellipsometer measurement, surface morphology observation, and two-temperature model calculations. We numerically demonstrate the application of the optically modulated refractive index of the phase-change thin films in a precisely adjustable color display. These results may provide further insights into ultrafast phase-transition mechanics and are useful in the design of programmable photonic and opto-electrical devices based on phase-change memory materials.

  13. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity.

    Science.gov (United States)

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-09-01

    Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Cross sectional study. Children (large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low.

  14. Trends in refractive surgery at an academic center: 2007-2009

    Directory of Open Access Journals (Sweden)

    Kuo Irene C

    2011-05-01

    Full Text Available Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK vs. laser-assisted in-situ keratomileusis (LASIK, and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10. The

  15. Trends in refractive surgery at an academic center: 2007-2009.

    Science.gov (United States)

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0

  16. Pulse energy dependence of refractive index change in lithium niobium silicate glass during femtosecond laser direct writing.

    Science.gov (United States)

    Cao, Jing; Poumellec, Bertrand; Brisset, François; Lancry, Matthieu

    2018-03-19

    Femtosecond laser-induced refractive index changes in lithium niobium silicate glass were explored at high repetition rate (300 fs, 500 kHz) by polarized light microscopy, full-wave retardation plate, quantitative birefringence microscopy, and digital holographic microscopy. We found three regimes on energy increase. The first one corresponds to isotropic negative refractive index change (for pulse energy ranging 0.4-0.8 μJ/pulse, 0.6 NA, 5μm/s, 650μm focusing depth in the glass). The second one (0.8-1.2 μJ/pulse) corresponds to birefringence with well-defined slow axis orientation. The third one (above 1.2 μJ/pulse) is related to birefringence direction fluctuation. Interestingly, these regimes are consistent with crystallization ones. In addition, an asymmetric orientational writing effect has been detected on birefringence. These topics extend the possibility of controlling refractive index change in multi-component glasses.

  17. Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.

    Science.gov (United States)

    Shraiki, Mario; Arba-Mosquera, Samuel

    2011-06-01

    To evaluate ablation algorithms and temperature changes in laser refractive surgery. The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.

  18. Composition of the excimer laser-induced plume produced during LASIK refractive surgery

    Science.gov (United States)

    Glickman, Randolph D.; Liu, Yun; Mayo, George L.; Baribeau, Alan D.; Starck, Tomy; Bankhead, Tom

    2003-07-01

    Because of concerns about potential hazards to surgical personnel of the plume associated with laser refractive surgery, this study was performed to characterize the composition of such plumes. Filter elements were removed from the smoke evacuator of a VISX S3 excimer laser (filter pore size ~0.3 microns) and from a Mastel Clean Room ( filter pore size ~0.2 microns) used with a LADARVISION excimer laser. The filters from both laser systems captured the laser-induced plumes from multiple, routine, LASIK patient procedures. Some filters were processed for scanning electron microscopy, while others were extracted with methanol and chloroform for biochemical analysis. Both the VISX "Final Air" filter and the Mastel "Clean Room" filter captured material that was not observed in filters that had clean operating room air only passed through them. In the VISX system, air flows through the filter unit parallel to the filter matrix. SEM analysis showed these filters captured discrete particles of 0.3 to 3.0 microns in size. In the Mastel Clean Room unit, air flows orthogonally through the filter, and the filter matrix was heavily layered with captured debris so that individual particles were not readily distinguished. Amino acid analysis and gel electrophoresis of extracted material revealed proteinaceous molecules as large as 5000 molecular weight. Such large molecules in the laser plume are not predicted by the existing theory of photochemical ablation. The presence of relatively large biomolecules may constitute a risk of allergenic reactions in personnel exposed to the plume, and also calls into question the precise mechanism of excimer laser photochemical ablation. Supported by the RMG Research Endowment, and Research to Prevent Blindness

  19. Retrospective Analysis of the Post-Operative Changes in Higher-Order Aberrations: A Comparison of the WaveLight EX500 to the VISX S4 Laser in Refractive Surgery.

    Science.gov (United States)

    Reed, Donovan S; Apsey, Douglas; Steigleman, Walter; Townley, James; Caldwell, Matthew

    2017-11-01

    In an attempt to maximize treatment outcomes, refractive surgery techniques are being directed toward customized ablations to correct not only lower-order aberrations but also higher-order aberrations specific to the individual eye. Measurement of the entirety of ocular aberrations is the most definitive means to establish the true effect of refractive surgery on image quality and visual performance. Whether or not there is a statistically significant difference in induced higher-order corneal aberrations between the VISX Star S4 (Abbott Medical Optics, Santa Ana, California) and the WaveLight EX500 (Alcon, Fort Worth, Texas) lasers was examined. A retrospective analysis was performed to investigate the difference in root-mean-square (RMS) value of the higher-order corneal aberrations postoperatively between two currently available laser platforms, the VISX Star S4 and the WaveLight EX500 lasers. The RMS is a compilation of higher-order corneal aberrations. Data from 240 total eyes of active duty military or Department of Defense beneficiaries who completed photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK) refractive surgery at the Wilford Hall Ambulatory Surgical Center Joint Warfighter Refractive Surgery Center were examined. Using SPSS statistics software (IBM Corp., Armonk, New York), the mean changes in RMS values between the two lasers and refractive surgery procedures were determined. A Student t test was performed to compare the RMS of the higher-order aberrations of the subjects' corneas from the lasers being studied. A regression analysis was performed to adjust for preoperative spherical equivalent. The study and a waiver of informed consent have been approved by the Clinical Research Division of the 59th Medical Wing Institutional Review Board (Protocol Number: 20150093H). The mean change in RMS value for PRK using the VISX laser was 0.00122, with a standard deviation of 0.02583. The mean change in RMS value for PRK using the

  20. A Novel Laser Refractive Surgical Treatment for Presbyopia: Optics-Based Customization for Improved Clinical Outcome.

    Science.gov (United States)

    Pajic, Bojan; Pajic-Eggspuehler, Brigitte; Mueller, Joerg; Cvejic, Zeljka; Studer, Harald

    2017-06-13

    Laser Assisted in Situ Keratomileusis (LASIK) is a proven treatment method for corneal refractive surgery. Surgically induced higher order optical aberrations were a major reason why the method was only rarely used to treat presbyopia, an age-related near-vision loss. In this study, a novel customization algorithm for designing multifocal ablation patterns, thereby minimizing induced optical aberrations, was used to treat 36 presbyopic subjects. Results showed that most candidates went from poor visual acuity to uncorrected 20/20 vision or better for near (78%), intermediate (92%), and for distance (86%) vision, six months after surgery. All subjects were at 20/25 or better for distance and intermediate vision, and a majority (94%) were also better for near vision. Even though further studies are necessary, our results suggest that the employed methodology is a safe, reliable, and predictable refractive surgical treatment for presbyopia.

  1. Miniature interferometer for refractive index measurement in microfluidic chip

    Science.gov (United States)

    Chen, Minghui; Geiser, Martial; Truffer, Frederic; Song, Chengli

    2012-12-01

    The design and development of the miniaturized interferometer for measurement of the refractive index or concentration of sub-microliter volume aqueous solution in microfludic chip is presented. It is manifested by a successful measurement of the refractive index of sugar-water solution, by utilizing a laser diode for light source and the small robust instrumentation for practical implementation. Theoretically, the measurement principle and the feasibility of the system are analyzed. Experimental device is constructed with a diode laser, lens, two optical plate and a complementary metal oxide semiconductor (CMOS). Through measuring the positional changes of the interference fringes, the refractive index change are retrieved. A refractive index change of 10-4 is inferred from the measured image data. The entire system is approximately the size of half and a deck of cards and can operate on battery power for long time.

  2. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    Science.gov (United States)

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  3. Determination of refractive and volatile elements in sediment using laser ablation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Duodu, Godfred Odame [School of Chemistry, Physics and Mechanical Engineering, Science and Engineering Faculty, Queensland University of Technology (QUT), 2 George St, 4001, QLD (Australia); Goonetilleke, Ashantha [School of Civil Engineering and Built Environment, Science and Engineering Faculty, Queensland University of Technology (QUT), 2 George St, 4001, QLD (Australia); Allen, Charlotte [Institute for Future Environments, Queensland University of Technology (QUT), 2 George St, 4001, QLD (Australia); Ayoko, Godwin A., E-mail: g.ayoko@qut.edu.au [School of Chemistry, Physics and Mechanical Engineering, Science and Engineering Faculty, Queensland University of Technology (QUT), 2 George St, 4001, QLD (Australia)

    2015-10-22

    Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (−52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments. - Highlights: • Wet milling was used to produce pressed tablet sediment for LA-ICP-MS analysis. • Milling was effective for refractive elements with narrow range of particle size. • This is the first use of LA-ICP-MS for Hg analysis in sediment samples. • Acceptable accuracy and precision were obtained for most of the elements studied. • Detection limits down to parts per trillion were observed for some elements.

  4. Determination of refractive and volatile elements in sediment using laser ablation inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Duodu, Godfred Odame; Goonetilleke, Ashantha; Allen, Charlotte; Ayoko, Godwin A

    2015-10-22

    Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (-52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Refractive index modulation of Sb{sub 70}Te{sub 30} phase-change thin films by multiple femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Kai; Wang, Yang, E-mail: ywang@siom.ac.cn; Jiang, Minghui; Wu, Yiqun [Key Laboratory of High Power Laser Materials, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2016-05-07

    In this study, the controllable effective refractive index modulation of Sb{sub 70}Te{sub 30} phase-change thin films between amorphous and crystalline states was achieved experimentally by multiple femtosecond laser pulses. The modulation mechanism was analyzed comprehensively by a spectral ellipsometer measurement, surface morphology observation, and two-temperature model calculations. We numerically demonstrate the application of the optically modulated refractive index of the phase-change thin films in a precisely adjustable color display. These results may provide further insights into ultrafast phase-transition mechanics and are useful in the design of programmable photonic and opto-electrical devices based on phase-change memory materials.

  6. Trends in refractive surgery at an academic center: 2007-2009

    OpenAIRE

    Kuo, Irene C

    2011-01-01

    Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in t...

  7. Measurement of the effective refractive index of a turbid colloidal suspension using light refraction

    International Nuclear Information System (INIS)

    Reyes-Coronado, A; Garcia-Valenzuela, A; Sanchez-Perez, C; Barrera, R G

    2005-01-01

    We propose and analyse a simple method to measure simultaneously the real and imaginary parts of the effective refractive index of a turbid suspension of particles. The method is based on measurements of the angle of refraction and transmittance of a laser beam that traverses a hollow glass prism filled with a colloidal suspension. We provide a comprehensive assessment of the method. It can offer high sensitivity while still being simple to interpret. We present results of experiments using an optically turbid suspension of polystyrene particles and compare them with theoretical predictions. We also report experimental evidence showing that the refractive behaviour of the diffuse component of light coming from a suspension depends on the volume fraction of the colloidal particles

  8. Role of percent peripheral tissue ablated on refractive outcomes following hyperopic LASIK

    Science.gov (United States)

    Stapleton, Fiona; Versace, Patrick

    2017-01-01

    Objectives To determine the effect of hyperopic laser in situ keratomileusis (H-LASIK) on corneal integrity, by investigating relationships between proportionate corneal tissue ablated and refractive outcomes at 3 months. Methods 18 eyes of 18 subjects treated with H-LASIK by Technolas 217c Excimer Laser were included in the study. Orbscan II Topography System was used to determine corneal volume and pachymetry 3mm temporally (3T). The volume of corneal tissue ablated was determined from the laser nomogram. Univariate associations between age, treatment, corneal volume, overall proportion of tissue removed, proportion of tissue removed at 3T, residual bed thickness at 3T and refractive outcomes 3 months post-LASIK were examined and independent factors associated with refractive outcomes determined using linear regression models. Results At 3 months post-LASIK, the mean difference to expected refractive outcome was -0.20 ± 0.64 (Range -2.00 to +1.00). In univariate analysis, difference to expected refractive outcome was associated with proportion of tissue removed at 3T (PLASIK, may present as either over or under-corrected at 3 months. The proportion of tissue removed at 3T was the single significant determinant of this outcome, suggesting unexpected biomechanical alterations resulting in corneal steepening. Future hyperopic LASIK procedures could consider proportionate volume of corneal tissue removed at 3T in addition to laser nomograms to achieve improved refractive outcomes. PMID:28151939

  9. Direct laser writing of a low-loss waveguide with independent control over the transverse dimension and the refractive index contrast between the core and the cladding.

    Science.gov (United States)

    Masselin, Pascal; Bychkov, Eugène; Coq, David Le

    2016-08-01

    In this Letter, we present the realization of a low-loss waveguide in a chalcogenide glass by direct laser writing technique in a particular configuration that allows the independent control over the diameter of the core and the magnitude of the refractive index contrast with the cladding. The waveguide is of multicore type and composed of 19 channels arranged on a hexagonal lattice. Each channel is obtained by stacking voxels of refractive index variation obtained by static exposure to femtosecond laser pulse burst. The distance between the channels can be used to vary the diameter of the waveguide, while the duration of laser burst controls the magnitude of the effective index and the propagation loss. We demonstrate that it can be reduced down to 0.11 dB/cm.

  10. Meta analysis of therapeutic effects of domestic deproteinized calf blood extract eye gel on corneal epithelial repair after laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Jian Zhang

    2018-01-01

    Full Text Available AIM: To systemically evaluate the clinical efficacy and safety of domestic deproteinized calf blood extract eye gel for corneal epithelial repair after laser refractive surgery. METHODS:We performed a comprehensive search via Pubmed, Embase, Cochrane Library, VIP Chinese Science and Technology Journal Database, CNKI and Wan Fang Chinese periodical Database for the randomized controlled trials(RCTsat home and abroad about effects of the domestic deproteinized calf blood extract eye gel for corneal epithelial repair after laser corneal refractive surgery with retrieval time from January 2007 to December 2016. According to the inclusion and exclusion criteria, 2 medical researchers independently screened documents, extracted data and evaluated the quality. Review Manager 5.3 software was used for Meta analysis. RESULTS: Seven RCTs involving 1 042 eyes, including 523 eyes in the treatment group and 519 eyes in the control group, were selected for this Meta-analysis. The results showed that the clinical efficacy in the treatment group was better than that in the control group(OR=1.81, 95%CI: 1.39~2.35; PWMD=-0.33, 95%CI: -0.45 to -0.21; PWMD=-1.26, 95%CI: -1.56 to -0.97; PCONCLUSION: The domestic deproteinized calf blood extract eye gel can relieve the patients' symptoms after laser refractive surgery, improve the corneal epithelial recovery and the efficiency of treatment. Due to the limited quality and quantity of the studies these conclusions should be further validated by more well-designed randomized double blind controlled trials.

  11. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  12. Refractive index inhomogeneity within an aerogel block

    International Nuclear Information System (INIS)

    Bellunato, T.; Calvi, M.; Da Silva Costa, C.F.; Matteuzzi, C.; Musy, M.; Perego, D.L.

    2006-01-01

    Evaluating local inhomogeneities of the refractive index inside aerogel blocks to be used as Cherenkov radiator is important for a high energy physics experiment where angular resolution is crucial. Two approaches are described and compared. The first one is based on the bending of a laser beam induced by refractive index gradients along directions normal to the unperturbed optical path. The second method exploits the Cherenkov effect itself by shooting an ultra-relativistic collimated electron beam through different points of the aerogel surface. Local refractive index variations result in sizable differences in the Cherenkov photons distribution

  13. Control of laser-beam propagation and absorption in a nanoplasma gas by programming of a transient complex refractive index with a prepulse

    International Nuclear Information System (INIS)

    Chu, H.-E.; Xiao, Y.-F.; Tsai, H.-E.; Lee, C.-H.; Lin, J.-Y.; Wang, J.; Chen, S.-Y.

    2004-01-01

    By utilizing the intensity- and duration-dependent heating and expansion rate of nanoplasma to generate a transient transverse gradient of the refractive index, prepulse controlled laser-beam propagation is demonstrated. The dynamical response of the macroscopic optical refractive index is traced back to the microscopic polarizability of nanoplasmas experimentally, in accordance with hydrodynamic nanoplasma models. In particular, the delay between the prepulse and the main pulse for maximum Rayleigh scattering is found to be longer than that for maximum x-ray emission, supporting the more refined one-dimensional self-consistent hydrodynamic nanoplasma model

  14. Study of the refractive index change in a-Si:H thin films patterned by 532 nm laser radiation for photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Colina, M., E-mail: monica.colina.brito@upm.e [Centro Laser UPM, Univ. Politecnica de Madrid, Ctra. de Valencia Km 7.3, 28031 Madrid (Spain); Molpeceres, C.; Holgado, M. [Centro Laser UPM, Univ. Politecnica de Madrid, Ctra. de Valencia Km 7.3, 28031 Madrid (Spain); Gandia, J. [Dept. de Energias Renovables, Energia Solar Fotovoltaica, CIEMAT, Avda, Complutense 22, 28040 Madrid (Spain); Nos, O. [CeRMAE Dept. Fisica Aplicada i Optica, Universitat de Barcelona, Av. Diagonal 647, 08028 Barcelona (Spain); Ocana, J.L. [Centro Laser UPM, Univ. Politecnica de Madrid, Ctra. de Valencia Km 7.3, 28031 Madrid (Spain)

    2010-07-01

    Laser scribing of hydrogenated amorphous silicon (a-Si:H) is a crucial step in the fabrication of thin film photovoltaic modules. During such process, inherent thermo-mechanical effects associated to laser ablation mechanisms lead to thermal damages. In that sense, the state of the material remaining in the vicinity of the ablated area has a critical influence on the electrical properties of the final devices. In this work, a comprehensive analysis of refractive index variations for the material surrounding the ablated area by means of Infrared-Visible Fourier transform spectrometry is proposed. Besides, in order to evaluate the material microstructure, Raman spectroscopy is employed as a complimentary technique. It was seen that the refractive index variation decreased as the distance from the center of the ablated groove was increased. Likewise, a clear transition from highly crystalline to amorphous material could be also observed as a function of the distance from the groove.

  15. Study of the refractive index change in a-Si:H thin films patterned by 532 nm laser radiation for photovoltaic applications

    International Nuclear Information System (INIS)

    Colina, M.; Molpeceres, C.; Holgado, M.; Gandia, J.; Nos, O.; Ocana, J.L.

    2010-01-01

    Laser scribing of hydrogenated amorphous silicon (a-Si:H) is a crucial step in the fabrication of thin film photovoltaic modules. During such process, inherent thermo-mechanical effects associated to laser ablation mechanisms lead to thermal damages. In that sense, the state of the material remaining in the vicinity of the ablated area has a critical influence on the electrical properties of the final devices. In this work, a comprehensive analysis of refractive index variations for the material surrounding the ablated area by means of Infrared-Visible Fourier transform spectrometry is proposed. Besides, in order to evaluate the material microstructure, Raman spectroscopy is employed as a complimentary technique. It was seen that the refractive index variation decreased as the distance from the center of the ablated groove was increased. Likewise, a clear transition from highly crystalline to amorphous material could be also observed as a function of the distance from the groove.

  16. Experimental refractive index determination of the optic fiber's core

    International Nuclear Information System (INIS)

    Oezelsoy, S.

    2005-01-01

    In this work, the Fresnel's fundamental Law was used to be able to obtain the refractive index of the fiber optic's core. The intensity of light reflected from the boundary between two mediums was measured by the optical powermeter (Melles Griot, Universal optical powermeter). In recent technology, the light that is illuminated from the light source can be transported to the boundary region and measured with minimum loss by using the optic fibers which make the measurement more sensitively. The liquid and the optic fiber's core whose refractive indices will be measured are the two mediums and the surface of the optic fiber's core is the boundary region. By dipping the fiber optic probe to the liquids, the reflected light intensities were measured with powermeter via Silicon Detector for single mode fiber and multimode fiber respectively to obtain the refractive index of the optic fiber's core. At this work, because of the using the diode laser with 661,4 nm (FWHM) and He-Ne laser with 632,8 nm (FWHM) the refractive indices were measured at this wavelengthes with the Refractometer (Abbe 60-70, Bellingham+Stanley). If the refractive indices of two mediums are equal, the light doesn't reflect from the boundary. The graphic is drawn depend upon the refractive index of the liquids versus the back reflected light energy and from the minimum point of the curve the effective refractive index of the fiber optic's core is calculated for 661,4 nm and 780 nm

  17. [Advocating standardization and customization of corneal refractive surgery in Chinese domestic situation].

    Science.gov (United States)

    Zhang, F J; Song, Y Z

    2016-07-01

    With the improvement and application of excimer laser and femtosecond laser equipment in clinical ophthalmology, the diversified strategies for corneal refractive surgery candidates have been provided. Based on the trend of " all-laser treatment", it is very necessary to take the domestic situation into consideration when a standard and customized choice is made according to the indications of each specific surgical type. The characteristics and limitations of various surgeries are elucidated and commented here in order to provide some reasonable treatment options for refractive surgery. (Chin J Ophthalmol, 2016, 52: 481-485).

  18. Optomecatronic system to estimate the index of refraction of a Compound Chromic

    International Nuclear Information System (INIS)

    Garcia, L.; Camas, J.; Pola, L.; Castannon, H.; Mota, R.; Juarez, N.; Garcia, C.

    2012-01-01

    The paper presents an optomechatronic system, which it can detect the displacement of laser beam refracted by Lophine layer deposited in a slider. The displacement was estimated by mean of image processing. The displacement of the laser beam is a function of the refractive index of the Lophine layer as function of temperature change. The system uses a Graphical User Interface (GUI), where it is possible to control the incidence angle of the laser beam, and the same time, the temperature of the lophine layer can be sensed. (Author)

  19. Interferometric measurement of refractive index modification in a single mode microfiber

    Science.gov (United States)

    Ahmed, Farid; Ahsani, Vahid; Jun, Martin B. G.

    2017-02-01

    Efficient and cost effective measurement of the refractive index profile in an optical fiber is a significant technical job to design and manufacture in-fiber photonic devices and communication systems. For instance, to design fiber gratings, it is required to estimate the refractive index modulation to be inscribed by the fabrication apparatus such as ultraviolet or infrared lasers. Mach-Zehnder interferometer (MZI) based quantification of refractive index change written in single mode microfiber by femtosecond laser radiation is presented in this study. The MZI is constructed by splicing a microfiber (core diameter: 3.75 μm, cladding diameter: 40 μm) between standard single mode fibers. To measure the RI inscribed by infrared femtosecond laser, 200 μm length of the core within the MZI was scanned with laser radiation. As the higher index was written within 200 μm length of the core, the transmission spectrum of the interferometer displayed a corresponding red shift. The observed spectral shift was used to calculate the amount of refractive index change inscribed by the femtosecond irradiation. For the MZI length of 3.25 mm, and spectral shift of 0.8 nm, the calculated refractive index was found to be 0.00022. The reported results display excellent agreement between theory and experimental findings. Demonstrated method provides simple yet very effective on-site measurement of index change in optical fibers. Since the MZI can be constructed in diverse fiber types, this technique offers flexibility to quantify index change in various optical fibers.

  20. Nonlinearity of the refractive index due to an excitonic molecule resonance state in CdS

    International Nuclear Information System (INIS)

    Baumert, R.; Broser, I.; Buschick, K.

    1986-01-01

    The authors report the observation of an intensity-dependent refractive-index nonlinearity in CdS due to a resonance state where an excitonic molecule is created by induced absorption of light. The refractive index n as a function of the incident laser photon energy E is measured directly by light refraction in thin crystal prisms. A renormalized dielectric function describes the measured n(E) spectra well. This strong refractive-index nonlinearity is well suited to produce an optical bistability and to further strengthen the evidence of CdS to be an important material for laser-induced dynamic gratings

  1. Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery

    DEFF Research Database (Denmark)

    Krarup, Therese; Holm, Lars Morten; la Cour, Morten

    2014-01-01

    and the contralateral eye operated by CPS (stop and chop technique). Both eyes had intraocular aspheric lenses implanted. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), central corneal endothelial cell count and hexagonality with a non-contact specular microscope were assessed......PURPOSE: To investigate the amount of endothelial cell loss (ECL) and refractive predictability by femtosecond laser-assisted cataract surgery (FLACS) compared to conventional phacoemulsification cataract surgery (CPS). METHODS: Forty-seven patients had one eye operated by FLACS...

  2. Automatic diagnostic system for measuring ocular refractive errors

    Science.gov (United States)

    Ventura, Liliane; Chiaradia, Caio; de Sousa, Sidney J. F.; de Castro, Jarbas C.

    1996-05-01

    Ocular refractive errors (myopia, hyperopia and astigmatism) are automatic and objectively determined by projecting a light target onto the retina using an infra-red (850 nm) diode laser. The light vergence which emerges from the eye (light scattered from the retina) is evaluated in order to determine the corresponding ametropia. The system basically consists of projecting a target (ring) onto the retina and analyzing the scattered light with a CCD camera. The light scattered by the eye is divided into six portions (3 meridians) by using a mask and a set of six prisms. The distance between the two images provided by each of the meridians, leads to the refractive error of the referred meridian. Hence, it is possible to determine the refractive error at three different meridians, which gives the exact solution for the eye's refractive error (spherical and cylindrical components and the axis of the astigmatism). The computational basis used for the image analysis is a heuristic search, which provides satisfactory calculation times for our purposes. The peculiar shape of the target, a ring, provides a wider range of measurement and also saves parts of the retina from unnecessary laser irradiation. Measurements were done in artificial and in vivo eyes (using cicloplegics) and the results were in good agreement with the retinoscopic measurements.

  3. Measurement of the refractive index dispersion of As2Se3 bulk glass and thin films prior to and after laser irradiation and annealing using prism coupling in the near- and mid-infrared spectral range

    International Nuclear Information System (INIS)

    Carlie, N.; Petit, L.; Musgraves, J. D.; Richardson, K.; Anheier, N. C. Jr.; Qiao, H. A.; Bernacki, B.; Phillips, M. C.

    2011-01-01

    The prism coupling technique has been utilized to measure the refractive index in the near- and mid-IR spectral region of chalcogenide glasses in bulk and thin film form. A commercial system (Metricon model 2010) has been modified with additional laser sources, detectors, and a new GaP prism to allow the measurement of refractive index dispersion over the 1.5-10.6 μm range. The instrumental error was found to be ±0.001 refractive index units across the entire wavelength region examined. Measurements on thermally evaporated AMTIR2 thin films confirmed that (i) the film deposition process provides thin films with reduced index compared to that of the bulk glass used as a target, (ii) annealing of the films increases the refractive index of the film to the level of the bulk glass used as a target to create it, and (iii) it is possible to locally increase the refractive index of the chalcogenide glass using laser exposure at 632.8 nm.

  4. Estimates of Atmospheric Distortion Number for Nonlinear Refraction

    National Research Council Canada - National Science Library

    Roadcap, J. R; McNicholl, P. J; Beland, R. R; Jumper, G. Y

    2007-01-01

    A characteristic nondimensional distortion number Nd was derived in the 1970s that allows inference of the degree of nonlinear refraction or thermal blooming associated with an atmospheric laser path...

  5. Effective spectral dispersion of refractive index modulation

    Czech Academy of Sciences Publication Activity Database

    Vojtíšek, Petr; Květoň, M.; Richter, I.

    2017-01-01

    Roč. 19, č. 4 (2017), č. článku 045603. ISSN 2040-8978 R&D Projects: GA MŠk(CZ) LO1206 Institutional support: RVO:61389021 Keywords : volume gratings * holography * dispersion * refractive index modulation Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.741, year: 2016 http://iopscience.iop.org/article/10.1088/2040-8986/aa6092/meta

  6. Coagulase-negative staphylococci isolated from ocular wound infections after laser refractive surgery: attachment to and accumulation on soft contact lenses.

    Science.gov (United States)

    Faghri, Jamshid; Razavi, Mohamad Reza

    2009-03-01

    Disposable soft contact lenses that are commonly used after laser refractive surgery are known to be colonized by bacteria and play a key role in Bacterial Keraitis (BK) pathogenesis. Coagulase-negative staphylococci (CoNS) have been found to be the most common pathogen involved in this postoperative infection. In this study a rapid and a simple assay was developed for studying attachment and accumulation of CoNS on soft contact lenses in vitro using [3H] thymidine. Thirty-five isolates of CoNS were obtained from 27 laser refractive surgery patients. Twenty-five of these thirty-five CoNS were isolated in multiple cultures. Ten CoNS were isolated in cultures from patients who underwent reoperation. The assay was optimized using a biofilm-producing strain, S. epidermidis RP62A, which was subcultured overnight at 37 degrees C on blood agar medium. Quantitative determination of biofilm production was tested. Presence of the genes icaADB and icaD was determined in all isolates. All isolates were biochemically analyzed using the Phene Plate (PhP) system modified for typing of CoNS. The CoNS isolates were further characterized to species level using ID32Staph.Mann-Whitney rank sum test and chi-square test were used to identify statistical differences in adherence, index, antibiotic susceptibility patterns, and biofilm production or presence of the ica operon between clinically significant isolates and non-postoperative BK isolates. No differences in attachment and accumulation were found between isolates causing BK after laser refractive surgery and contaminant isolates. In addition, there were no differences in the distribution of the ica operon between the two groups, as determined by polymerase chain reaction. Nevertheless, the ability to produce biofilm was found to be present significantly more frequently among BK isolates than among non-postoperative BK isolates. This study shows that the method using radioactive thymidine to analyze adherence of CoNS to soft

  7. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity

    Science.gov (United States)

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-01-01

    Purpose: Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Methods: Cross sectional study. Children (biometric status. Results: Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6–15 years) were included. Mean spherical equivalent (SE) was −4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. Conclusion: There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low. PMID:28905827

  8. Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector.

    Science.gov (United States)

    Dekker, Kurtis H; Battista, Jerry J; Jordan, Kevin J

    2016-08-01

    The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve

  9. Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

    Energy Technology Data Exchange (ETDEWEB)

    Dekker, Kurtis H., E-mail: kdekker2@uwo.ca [Department of Medical Biophysics, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, Ontario N6A 5C1 (Canada); Battista, Jerry J.; Jordan, Kevin J. [Departments of Medical Biophysics and Oncology, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, Ontario N6A 5C1, Canada and Department of Physics and Engineering, London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario N6A 4L6 (Canada)

    2016-08-15

    Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60

  10. Hugoniot and refractive indices of bromoform under shock compression

    Science.gov (United States)

    Liu, Q. C.; Zeng, X. L.; Zhou, X. M.; Luo, S. N.

    2018-01-01

    We investigate physical properties of bromoform (liquid CHBr3) including compressibility and refractive index under dynamic extreme conditions of shock compression. Planar shock experiments are conducted along with high-speed laser interferometry. Our experiments and previous results establish a linear shock velocity-particle velocity relation for particle velocities below 1.77 km/s, as well as the Hugoniot and isentropic compression curves up to ˜21 GPa. Shock-state refractive indices of CHBr3 up to 2.3 GPa or ˜26% compression, as a function of density, can be described with a linear relation and follows the Gladstone-Dale relation. The velocity corrections for laser interferometry measurements at 1550 nm are also obtained.

  11. Hugoniot and refractive indices of bromoform under shock compression

    Directory of Open Access Journals (Sweden)

    Q. C. Liu

    2018-01-01

    Full Text Available We investigate physical properties of bromoform (liquid CHBr3 including compressibility and refractive index under dynamic extreme conditions of shock compression. Planar shock experiments are conducted along with high-speed laser interferometry. Our experiments and previous results establish a linear shock velocity−particle velocity relation for particle velocities below 1.77 km/s, as well as the Hugoniot and isentropic compression curves up to ∼21 GPa. Shock-state refractive indices of CHBr3 up to 2.3 GPa or ∼26% compression, as a function of density, can be described with a linear relation and follows the Gladstone-Dale relation. The velocity corrections for laser interferometry measurements at 1550 nm are also obtained.

  12. Suppression of Air Refractive Index Variations in High-Resolution Interferometry

    Directory of Open Access Journals (Sweden)

    Zdeněk Buchta

    2011-08-01

    Full Text Available The influence of the refractive index of air has proven to be a major problem on the road to improvement of the uncertainty in interferometric displacement measurements. We propose an approach with two counter-measuring interferometers acting as a combination of tracking refractometer and a displacement interferometer referencing the wavelength of the laser source to a mechanical standard made of a material with ultra-low thermal expansion. This technique combines length measurement within a specified range with measurement of the refractive index fluctuations in one axis. Errors caused by different position of the interferometer laser beam and air sensors are thus eliminated. The method has been experimentally tested in comparison with the indirect measurement of the refractive index of air in a thermal controlled environment. Over a 1 K temperature range an agreement on the level of 5 × 10−8 has been achieved.

  13. Laser--plasma interaction in a theta-pinch geometry

    International Nuclear Information System (INIS)

    Armstrong, W.T.

    1978-06-01

    Prompt stimulated Brillouin scatter (SBS) is studied in an experiment wherein a high power, pulsed CO 2 laser irradiates an independently produced, theta-pinch plasma. SBS does not significantly affect laser heating of the plasma. Measurements of density profiles and temperature histories permitted examination of laser refraction, local heating and net absorption. Refractive containment of the CO 2 laser beam by an on-axis density minimum was observed at early times during the laser pulse. However, refractive containment was lost at late times due to the diffusive loss of the density minimum. Classical modeling of the expected heating required ''bleached'' absorption to account for the observed heating. A plasma absorptivity of approximately 46% was inferred from calorimetry measurements at 250 mtorr fill pressure. These results confirm that classical heating and refraction dominated the laser-plasma interaction

  14. Light focusing from large refractive indices in ionized air

    International Nuclear Information System (INIS)

    Robledo-Martinez, A.; Sobral, H.; Villagran-Muniz, M.; Bredice, F.

    2008-01-01

    The sheath that surrounds a laser-induced plasma in air was investigated with a light probe. The sheath is a 3-mm-thick halo of ionized gas created by ultraviolet light emitted from the plasma core. A beam of laser light tracked with a streak camera was employed to probe it. It was found that in the first hundreds of a nanosecond after plasma inception, the beam is deflected towards the plasma center. This result points to a high refractive index inside the sheath. The index values obtained (up to 2.0) are due to an increased susceptibility caused by a bulk electric polarization. Using previous results on the sheath's electric polarizability values, the refractive index was calculated and was found to agree with the observed indices. The application of the electric polarization model to the guiding of laser beams and to plasma lenses is also discussed.

  15. Frequency comb calibrated frequency-sweeping interferometry for absolute group refractive index measurement of air.

    Science.gov (United States)

    Yang, Lijun; Wu, Xuejian; Wei, Haoyun; Li, Yan

    2017-04-10

    The absolute group refractive index of air at 194061.02 GHz is measured in real time using frequency-sweeping interferometry calibrated by an optical frequency comb. The group refractive index of air is calculated from the calibration peaks of the laser frequency variation and the interference signal of the two beams passing through the inner and outer regions of a vacuum cell when the frequency of a tunable external cavity diode laser is scanned. We continuously measure the refractive index of air for 2 h, which shows that the difference between measured results and Ciddor's equation is less than 9.6×10-8, and the standard deviation of that difference is 5.9×10-8. The relative uncertainty of the measured refractive index of air is estimated to be 8.6×10-8. The data update rate is 0.2 Hz, making it applicable under conditions in which air refractive index fluctuates fast.

  16. Periodic refractive index modifications inscribed in polymer optical fibre by focussed IR femtosecond pulses

    DEFF Research Database (Denmark)

    Stecher, Matthias; Williams, Robert J.; Bang, Ole

    Focussed femtosecond laser pulses were used to inscribe a periodic array of modifications in the core of a polymer optical fibre. Structural and refractive-index modifications have been observed at different pulse energies using DIC microscopy.......Focussed femtosecond laser pulses were used to inscribe a periodic array of modifications in the core of a polymer optical fibre. Structural and refractive-index modifications have been observed at different pulse energies using DIC microscopy....

  17. The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism.

    Science.gov (United States)

    Aslanides, Ioannis M; Toliou, Georgia; Padroni, Sara; Arba Mosquera, Samuel; Kolli, Sai

    2011-06-01

    To compare the refractive and visual outcomes using the Schwind Amaris excimer laser in patients with high astigmatism (>1D) with and without the static cyclotorsion compensation (SCC) algorithm available with this new laser platform. 70 consecutive eyes with ≥1D astigmatism were randomized to treatment with compensation of static cyclotorsion (SCC group- 35 eyes) or not (control group- 35 eyes). A previously validated optimized aspheric ablation algorithm profile was used in every case. All patients underwent LASIK with a microkeratome cut flap. The SCC and control group did not differ preoperatively, in terms of refractive error, magnitude of astigmatism or in terms of cardinal or oblique astigmatism. Following treatment, average deviation from target was SEq +0.16D, SD±0.52 D, range -0.98 D to +1.71 D in the SCC group compared to +0.46 D, SD±0.61 D, range -0.25 D to +2.35 D in the control group, which was statistically significant (p<0.05). Following treatment, average astigmatism was 0.24 D (SD±0.28 D, range -1.01 D to 0.00 D) in the SCC group compared to 0.46 D (SD±0.42 D, range -1.80 D to 0.00 D) in the control group, which was highly statistically significant (p<0.005). There was no statistical difference in the postoperative uncorrected vision when the aspheric algorithm was used although there was a trend to increased number of lines gained in the SCC group. This study shows that static cyclotorsion is accurately compensated for by the Schwind Amaris laser platform. The compensation of static cyclotorsion in patients with moderate astigmatism produces a significant improvement in refractive and astigmatic outcomes than when not compensated. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Giant Kerr nonlinearities using refractive-index enhancement

    International Nuclear Information System (INIS)

    Yavuz, D. D.; Sikes, D. E.

    2010-01-01

    By utilizing refractive-index enhancement with vanishing absorption, a scheme is suggested that achieves giant Kerr nonlinearities between two weak laser beams. One application of this scheme is discussed and an all-optical distributed Bragg reflector is proposed that works at very low light levels.

  19. Refractive indices of CaF2 single crystals under elastic shock loading

    Science.gov (United States)

    Li, Y.; Zhou, X. M.; Liu, C. L.; Luo, S. N.

    2017-07-01

    Refractive indices and Hugoniots of CaF2 single crystals are investigated by laser displacement interferometry under shock loading below 5 GPa. Birefringence is observed for the [110] loading. We obtain the Hugoniot equation of states for [100], [110] and [111], and refractive indices for these orientations with consideration of their polarization. The measured refractive indices are in reasonable agreement with predictions based on the piezo-optic theory, and are used to refine the elasto-optic coefficients.

  20. Aero-Optical Wavefront Propagation and Refractive Fluid Interfaces in Large-Reynolds-Number Compressible Turbulent Flows

    National Research Council Canada - National Science Library

    Catrakis, Haris J; Jefferies, Rhett

    2005-01-01

    ... of the refractive field and interfaces. Direct, non-intrusive, and non-integrated imaging of the refractive index field in purely gaseous flows is achieved using laser induced fluorescence of acetone vapor molecularly premixed in air...

  1. Retinopatia da prematuridade: achados refrativos pós-tratamento com crioterapia ou laser Retinopathy of prematurity: refractive errors in patients treated with cryotherapy or laser

    Directory of Open Access Journals (Sweden)

    Sara Pozzi

    2000-10-01

    Full Text Available Objetivos: Determinar e comparar as características refrativas de uma população composta de crianças pré-termo com retinopatia da prematuridade que necessitaram de tratamento com crioterapia ou laserterapia. Método: Análise dos resultados da refração estática de 14 pacientes (de um total de 761 fichas de crianças que nasceram no Hospital São Paulo da Universidade Federal de São Paulo - Escola Paulista de Medicina, entre janeiro de 1988 e abril de 1998, que completaram um ano de idade e que apresentaram Retinopatia da Prematuridade grau 3 com características de "doença limiar" sendo tratadas com crioterapia ou laserterapia. Foram utilizados os testes estatísticos de Wilcoxon e Mann-Whitney para a avaliação dos resultados. Resultados: 64,3% dos pacientes apresentaram miopia. No grupo de pacientes que receberam tratamento com crioterapia, 80% mostrou miopia, que em todos os casos foi alta; 20% hipermetropia leve, com uma média para o equivalente esférico de --3,10 D no olho direito e --3,25 D no olho esquerdo (diferença entre ambos os olhos estatísticamente não significante. No grupo de laserterapia, 55,6% mostrou miopia, sendo 20 % dos casos miopia alta e 80% miopia leve; 11,1% apresentou-se sem ametropia e 33,3 % com hipermetropia leve. O valor da média para o equivalente esférico foi --0,58 D no olho direito e --0,83D no olho esquerdo (diferença entre ambos os olhos estatisticamente significante. A comparação dos resultados refracionais dos dois grupos mostrou uma maior incidência para miopia alta no grupo de pacientes que receberam tratamento com crioterapia (PPurpose: To examine the spherical equivalent of refractive errors in preterm children with threshold retinopathy of prematurity treated with cryotherapy or laser. Patients and Method: A group of 14 one-year-old children (selected from 761 preterm children born at the Hospital São Paulo of the Universidade Federal de São Paulo between 1988 and 1998 with stage

  2. Femtosecond refractive-index tailoring of an optical fiber and phase retrieval from far-field measurements

    DEFF Research Database (Denmark)

    Savolainen, Juha-Matti; Grüner-Nielsen, Lars; Kristensen, Poul

    2013-01-01

    A refractive-index change is written inside an optical fiber close to the end face by femtosecond laser light. The induced phase change is measured by analyzing the far-field intensity profiles before and after the irradiation.......A refractive-index change is written inside an optical fiber close to the end face by femtosecond laser light. The induced phase change is measured by analyzing the far-field intensity profiles before and after the irradiation....

  3. Seguridad del paciente en la cirugía refractiva con láser Safety of the patients in the refractive surgery with laser

    Directory of Open Access Journals (Sweden)

    Yureisi Labarrere Cruz

    2012-06-01

    Full Text Available Objetivo: Describir aspectos relacionados con la seguridad del paciente en la cirugía refractiva con láser y enumerar las medidas para disminuir el riesgo de complicaciones. Métodos: Se realizó un estudio descriptivo transversal. El universo de estudio y la muestra se conformó por 11 720 ojos correspondientes a 5 955 pacientes que fueron intervenidos de cirugía refractiva con láser de excímeros entre los años 2005 y 2009 en el salón de cirugía refractiva del Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Los datos se presentaron en tablas y gráficos, procesados en el paquete estadístico Statgraph Plus 50. Resultados: El número de ojos operados tuvo un aumento progresivo y su mayor representación en los años 2008 y 2009 (24,5 % y 25,1 %, respectivamente. Las complicaciones representaron 0,74 % del total de ojos intervenidos y con tendencia a la disminución en el tiempo. Conclusión: Existe un aumento en la demanda de la cirugía refractiva por láser en nuestro medio para la corrección de los defectos refractivos. Es necesario cumplir un conjunto de medidas que disminuyen la presencia de complicaciones, así se brinda mayor seguridad al paciente.Objective: To Identify and to describe aspects of the patient's safety in the refractive surgery with laser, as well as the measures to reduce the risk of complications. Methods: A cross-sectional descriptive study was undertaken. The universe of study was the sample of 11 720 eyes from 5 955 patients who had undergone refractive surgery with excímer laser from 2005 to 2009 in Refractive Surgery service of ¨Ramón Pando Ferrer¨ Cuban Institute of Ophthalmology. Data was processed by Statgraph Plus 50 package and presented in charts and graphics. Results: The number of operated eyes progressively increased and the biggest figure was reached in 2008 and 2009, accounting for 24.5% and 25.1% respectively. The complications occurred in 0.74 % of the total of operated eyes, with a

  4. New vistas in refractive laser beam shaping with an analytic design approach

    Science.gov (United States)

    Duerr, Fabian; Thienpont, Hugo

    2014-05-01

    Many commercial, medical and scientific applications of the laser have been developed since its invention. Some of these applications require a specific beam irradiance distribution to ensure optimal performance. Often, it is possible to apply geometrical methods to design laser beam shapers. This common design approach is based on the ray mapping between the input plane and the output beam. Geometric ray mapping designs with two plano-aspheric lenses have been thoroughly studied in the past. Even though analytic expressions for various ray mapping functions do exist, the surface profiles of the lenses are still calculated numerically. In this work, we present an alternative novel design approach that allows direct calculation of the rotational symmetric lens profiles described by analytic functions. Starting from the example of a basic beam expander, a set of functional differential equations is derived from Fermat's principle. This formalism allows calculating the exact lens profiles described by Taylor series coefficients up to very high orders. To demonstrate the versatility of this new approach, two further cases are solved: a Gaussian to at-top irradiance beam shaping system, and a beam shaping system that generates a more complex dark-hollow Gaussian (donut-like) irradiance profile with zero intensity in the on-axis region. The presented ray tracing results confirm the high accuracy of all calculated solutions and indicate the potential of this design approach for refractive beam shaping applications.

  5. Generation of surface electromagnetic waves in terahertz spectral range by free-electron laser radiation and their refractive index determination

    International Nuclear Information System (INIS)

    Bogomolov, G.D.; Jeong, Uk Young; Zhizhin, G.N.; Nikitin, A.K.; Zavyalov, V.V.; Kazakevich, G.M.; Lee, Byung Cheol

    2005-01-01

    First experiments for observation of surface electromagnetic waves (SEW) in the terahertz spectral range generated on dense aluminum films covering the optical quality glass plates are presented in this paper. Coherent radiation of the new free-electron laser covering the frequency range from 30 to 100cm -1 was used. The interference technique employing SEW propagation in the part of one shoulder of the asymmetric interferometer was applied. From the interference pattern the real part of SEW's effective refractive index ae ' was determined for the two laser emission wavelengths: at λ=150μm-ae ' =1+5x10 -5 , at λ=110μm-ae ' =1+8x10 -4 . High sensitivity of the interference patterns to overlayers made of Ge and Si with thickness of 100nm was demonstrated as well

  6. Risk assessment for ectasia after corneal refractive surgery.

    Science.gov (United States)

    Randleman, J Bradley; Woodward, Maria; Lynn, Michael J; Stulting, R Doyle

    2008-01-01

    To analyze the epidemiologic features of ectasia after excimer laser corneal refractive surgery, to identify risk factors for its development, and to devise a screening strategy to minimize its occurrence. Retrospective comparative and case-control study. All cases of ectasia after excimer laser corneal refractive surgery published in the English language with adequate information available through December 2005, unpublished cases seeking treatment at the authors' institution from 1998 through 2005, and a contemporaneous control group who underwent uneventful LASIK and experienced a normal postoperative course. Evaluation of preoperative characteristics, including patient age, gender, spherical equivalent refraction, pachymetry, and topographic patterns; perioperative characteristics, including type of surgery performed, flap thickness, ablation depth, and residual stromal bed (RSB) thickness; and postoperative characteristics including time to onset of ectasia. Development of postoperative corneal ectasia. There were 171 ectasia cases, including 158 published cases and 13 unpublished cases evaluated at the authors' institution. Ectasia occurred after LASIK in 164 cases (95.9%) and after photorefractive keratectomy (PRK) in 7 cases (4.1%). Compared with controls, more ectasia cases had abnormal preoperative topographies (35.7% vs. 0%; Pvs. 40.0 years; Pvs. -5.09 diopters; Pvs. 546.5 microm; Pvs. 317.3 microm; PLASIK that, if validated, represents a significant improvement over current screening strategies.

  7. Laser produced plasma density measurement by Mach-Zehnder interferometry

    International Nuclear Information System (INIS)

    Vaziri, A.; Kohanzadeh, Y.; Mosavi, R.K.

    1976-06-01

    This report describes an optical interferometric method of measuring the refractive index of the laser-produced plasma, giving estimates of its electron density. The plasma is produced by the interaction of a high power pulsed CO 2 laser beam with a solid target in the vacuum. The time varying plasma has a transient electron density. This transient electron density gives rise to a changing plasma refractive index. A Mach-Zehnder ruby laser interferometer is used to measure this refractive index change

  8. Nonlinear refraction at the absorption edge in InAs.

    Science.gov (United States)

    Poole, C D; Garmire, E

    1984-08-01

    The results of measurements of nonlinear refraction at the absorption edge in InAs between 68 and 90 K taken with an HF laser are compared with those of a band-gap resonant model in which the contribution of the light-hole band is included and found to account for more than 40% of the observed nonlinear refraction. A generalized expression for the nonlinear index is derived by using the complete Fermi-Dirac distribution function. Good agreement between theory and experiment is obtained, with no free parameters.

  9. Strategies for the management and prevention of complications in refractive laser surgery

    NARCIS (Netherlands)

    F. Hafezi (Farhad)

    2008-01-01

    textabstractObjective. Reoperations after refractive surgery have increased in frequency during the past 10 years. The spectrum of the indications for repeat LASIK may have changed. Methods. All cases of reoperations after refractive surgery performed between May 1, 2004 and April 30, 2005 at the

  10. Interplay between absorption, dispersion and refraction in high-order harmonic generation

    International Nuclear Information System (INIS)

    Dachraoui, H; Helmstedt, A; Bartz, P; Michelswirth, M; Mueller, N; Pfeiffer, W; Heinzmann, U; Auguste, T; Salieres, P

    2009-01-01

    We report a detailed experimental and theoretical study on high-order harmonic generation of a femtosecond Ti-sapphire laser focused at an intensity of around 10 15 W cm -2 onto a high-pressure (50-210 mbar) neon gas cell of variable length (1-3 mm). Using thorough three-dimensional simulations, we discuss the interplay between the different factors influencing the harmonic-generation efficiency, i.e. phase matching determined by the electronic and atomic dispersions, re-absorption of the harmonics by the medium and refraction of the generating laser beam. Generically, we find that, in our generation conditions, the emission yield of harmonics from the plateau region of the spectrum is absorption limited, whereas the emission from harmonics in the cut-off is strongly reduced due to both electron dispersion and ionization-induced refraction of the laser beam. A good agreement between the numerical results and the experimental data is obtained for the harmonic yield dependence on the various generation parameters (gas pressure, medium length and laser intensity).

  11. Differences between wavefront and subjective refraction for infrared light.

    Science.gov (United States)

    Teel, Danielle F W; Jacobs, Robert J; Copland, James; Neal, Daniel R; Thibos, Larry N

    2014-10-01

    To determine the accuracy of objective wavefront refractions for predicting subjective refractions for monochromatic infrared light. Objective refractions were obtained with a commercial wavefront aberrometer (COAS, Wavefront Sciences). Subjective refractions were obtained for 30 subjects with a speckle optometer validated against objective Zernike wavefront refractions on a physical model eye (Teel et al., Design and validation of an infrared Badal optometer for laser speckle, Optom Vis Sci 2008;85:834-42). Both instruments used near-infrared (NIR) radiation (835 nm for COAS, 820 nm for the speckle optometer) to avoid correction for ocular chromatic aberration. A 3-mm artificial pupil was used to reduce complications attributed to higher-order ocular aberrations. For comparison with paraxial (Seidel) and minimum root-mean-square (Zernike) wavefront refractions, objective refractions were also determined for a battery of 29 image quality metrics by computing the correcting lens that optimizes retinal image quality. Objective Zernike refractions were more myopic than subjective refractions for 29 of 30 subjects. The population mean discrepancy was -0.26 diopters (D) (SEM = 0.03 D). Paraxial (Seidel) objective refractions tended to be hyperopically biased (mean discrepancy = +0.20 D, SEM = 0.06 D). Refractions based on retinal image quality were myopically biased for 28 of 29 metrics. The mean bias across all 31 measures was -0.24 D (SEM = 0.03). Myopic bias of objective refractions was greater for eyes with brown irises compared with eyes with blue irises. Our experimental results are consistent with the hypothesis that reflected NIR light captured by the aberrometer originates from scattering sources located posterior to the entrance apertures of cone photoreceptors, near the retinal pigment epithelium. The larger myopic bias for brown eyes suggests that a greater fraction of NIR light is reflected from choroidal melanin in brown eyes compared with blue eyes.

  12. Optical wave microphone measurement during laser ablation of Si

    Energy Technology Data Exchange (ETDEWEB)

    Mitsugi, Fumiaki, E-mail: mitsugi@cs.kumamoto-u.ac.jp [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555 (Japan); Ide, Ryota; Ikegami, Tomoaki [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555 (Japan); Nakamiya, Toshiyuki; Sonoda, Yoshito [Graduate School of Industrial Engineering, Tokai University, 9-1-1 Toroku, Kumamoto, 862-8652 (Japan)

    2012-10-30

    Pulsed laser irradiation is used for surface treatment of a solid and ablation for particle formation in gas, liquid or supercritical phase media. When a pulsed laser is used to irradiate a solid, spatial refractive index variations (including photothermal expansion, shockwaves and particles) occur, which vary depending on the energy density of the pulsed laser. We focused on this phenomenon and applied an unique method for detection of refractive index variation using an optical wave microphone based on Fraunhofer diffraction. In this research, we analyzed the waveforms and frequencies of refractive index variations caused by pulsed laser irradiation of silicon in air and measured with an optical wave microphone.

  13. Fourth Order Nonlinear Intensity and the corresponding Refractive ...

    African Journals Online (AJOL)

    Nonlinear effects occur whenever the optical fields associated with one or more intense light such as from laser beams propagating in a crystal are large enough to produce polarization fields. This paper describes how the fourth order nonlinear intensity and the corresponding effective refractive index that is intensity ...

  14. Thermally stimulated nonlinear refraction in gelatin stabilized Cu-PVP nanocomposite thin films

    Energy Technology Data Exchange (ETDEWEB)

    Tamgadge, Y. S., E-mail: ystamgadge@gmail.com; Atkare, D. V. [Department of Physics, Mahatma Fule Arts, Commerce & SitaramjiChoudhari Science College, Warud, Dist. Amravati (MS), India-444906 (India); Pahurkar, V. G.; Muley, G. G., E-mail: gajananggm@yahoo.co.in [Department of Physics, SantGadge Baba Amravati University, Amravati (MS), India-444602 (India); Talwatkar, S. S. [Department of Physics, D K Marathe and N G Acharya College, Chembur, Mumbai (MS), India-440071 (India); Sunatkari, A. L. [Department of Physics, Siddharth College of Arts, Science and Commerce, Fort, Mumbai (MS), India-440001 (India)

    2016-05-06

    This article illustrates investigations on thermally stimulated third order nonlinear refraction of Cu-PVP nanocomposite thin films. Cu nanoparticles have been synthesized using chemical reduction method and thin films in PVP matrix have been obtained using spin coating technique. Thin films have been characterized by X-ray diffraction (XRD) and Ultraviolet-visible (UV-vis) spectroscopyfor structural and linear optical studies. Third order nonlinear refraction studies have been performed using closed aperture z-scan technique under continuous wave (CW) He-Ne laser. Cu-PVP nanocomposites are found to exhibit strong nonlinear refractive index stimulated by thermal lensing effect.

  15. Refractive surgery or contact lenses – how and when to decide?

    Directory of Open Access Journals (Sweden)

    Xu K

    2011-11-01

    Full Text Available Kunyong Xu1, Vishal Jhanji2 1Michael G DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong Abstract: Correction of refractive errors can be achieved with spectacles, contact lenses, and refractive surgery. The past decade has seen a surge in the availability of alternatives for patients and surgeons in terms of both surgical and nonsurgical options for the management of refractive errors. Newer generation contact lenses provide enhanced safety and better handling, whereas modern-day refractive surgery presents a plethora of choices based on the clinical characteristics and requirements of patients. We have moved from an era of "one size fits all" to a purely customized way of treating patients with refractive errors. This review presents the background, advantages, and disadvantages of the two most commonly used options for correction of ametropia, ie, contact lenses and refractive surgery. Keywords: laser-assisted in situ keratomileusis, contact lens, patient selection, complications, outcomes

  16. SURVEY OF SELECTED PROCEDURES FOR THE INDIRECT DETERMINATION OF THE GROUP REFRACTIVE INDEX OF AIR

    Directory of Open Access Journals (Sweden)

    Filip Dvořáček

    2018-02-01

    Full Text Available The main aim of the research was to evaluate numeric procedures of the indirect determination of the group refractive index of air and to choose the suitable ones for requirements of ordinary and high accuracy distance measurement in geodesy and length metrology. For this purpose, 10 existing computation methods were derived from various authors’ original publications and all were analysed for wide intervals of wavelengths and atmospheric parameters. The determination of the phase and the group refractive indices are essential parts in the evaluation of the first velocity corrections of laser interferometers and electronic distance meters. The validity of modern procedures was tested with respect to updated CIPM-2007 equations of the density of air. The refraction model of Leica AT401 laser tracker was analysed.

  17. The Refractive Index Measurement Of Silicon Dioxide Thin Film by the Coupling Prism Method

    International Nuclear Information System (INIS)

    Budianto, Anwar; Hariyanto, Sigit; Subarkah

    1996-01-01

    Refractive index of silicon dioxide thin film that doped with phosphor (SiO 2 :P) above the pure silicon dioxide substrate has been measured by light coupling prism method. The method principle is focusing the light on coupling prism base so that the light propagates into the waveguide layer while the reflected one forms a mode in the observation plane. The SiO 2 thin film as waveguide layer has a refractive index that give the thick and refractive index relation. The He-Ne laser as light source has the wavelength λ 0,6328 μm. The refractive index measurement of the thin film with the substrate refractive index n sb = 1,47 and the thin film thick d = 2μm gives n g = 1,5534 ± 0,01136. This method can distinguish the refractive index of thin film about 6% to the refractive index of substrate

  18. Laser Diode Pumped Solid State Lasers

    Science.gov (United States)

    1987-01-01

    Report N66001-83-C-0071, 17 April 1986, prepared for NOSC. 4.6 W.T. Welford, R. Winston , "The Option of Nonimaging Concentrators ," Academic Press, 1978...by non-imac optics such as reflective or refractive flux concentrators . Simple considerations regarding the optimum pumping configuration, high marks...reduced if the arrays can stand-off from the Nd:YAG laser. As mentioned before, compound parabolic concentrators or refractive optics cat employed to

  19. [Complications after refractive surgery abroad].

    Science.gov (United States)

    Terzi, E; Kern, T; Kohnen, T

    2008-05-01

    In this article a retrospective analysis of patients presenting at a German university following refractive surgery abroad is presented. A total of 20 cases of patients who had undergone treatment between 1998 and 2006 in China (1 case), Greece (1 case), Iran (1 case), Russia (2 cases), Switzerland (1 case), Slovakia (1 case), Spain (2 cases), South Africa (3 cases), Turkey (6 cases) and the USA (2 cases) were analyzed retrospectively. The following complications were observed: epithelial ingrowth into the interface with or without melting of the flap (6 cases), corneal ectasia (2 cases), dislocation of a phakic posterior chamber intraocular lens and prolapse into the anterior chamber with endothelial cell loss (1 case), secondary increase of intraocular pressure following implantation of a phakic intraocular lens (1 case), flap-related complications following laser-in-situ keratomileusis (LASIK) (2 cases), keratitis (1 case), dislocation of the complete flap (1 case), diffuse lamellar keratitis (DLK) grade IV (1 case), hyperopia as a consequence of radial keratotomy (1 case), and under correction/over correction and poor optical quality following laser epithelial keratomileusis (LASEK) and LASIK for high myopia (5 cases) with possible early corneal ectasia. There are four important problems arising from refractive surgery abroad, often referred to as "LASIK tourism": wrong indications, insufficient management of complications, lack of postoperative care and the health economic aspect.

  20. Visual outcome and refractive status in first 3 years of age in preterm infants suffered from laser-treated Type 1 retinopathy of prematurity (ROP): a 6-year retrospective review in a tertiary centre in Hong Kong.

    Science.gov (United States)

    Lok, Julie Y C; Yip, Wilson W K; Luk, Abbie S W; Chin, Joyce K Y; Lau, Henry H W; Young, Alvin L

    2018-02-01

    To report the visual outcome and refractive status in first 3 years of age in preterm infants suffered from laser-treated Type 1 retinopathy of prematurity (ROP): a 6-year review in Hong Kong DESIGN: Retrospective case series METHODOLOGY: Clinical records of all infants suffered from Type 1 ROP who had undergone laser therapy between 2007 and 2012 were retrospectively reviewed. Basic demographic data, serial changes of refractive error, visual acuity, severity of ROP and laser were analyzed. Correlation with myopia and astigmatism progression, body weight, height, growth and gestational age were also analyzed. Among 494 babies screened, 14 Chinese babies (26 eyes) recruited with 1:1 male-to-female ratio in this study. All eyes showed gradual progression of myopia in first 3 years of age but no significant change of astigmatism. Further correlation analysis showed no correlation with laser energy consumed, birth weight (p = 0.14), head circumference growth (p = 0.57) and body weight growth (p = 0.71). However, severity of myopia was related to the post-conceptual age when receiving laser therapy (p < 0.005), gestation age (p = 0.02) and possibly body height growth with age (p = 0.05). Myopia in early life is one of the most common ocular sequelae in Type 1 ROP survivors. Early detection of refractive error is important for prompt correction and visual rehabilitation to prevent amblyopia.

  1. Laser beam-plasma plume interaction during laser welding

    Science.gov (United States)

    Hoffman, Jacek; Moscicki, Tomasz; Szymanski, Zygmunt

    2003-10-01

    Laser welding process is unstable because the keyhole wall performs oscillations which results in the oscillations of plasma plume over the keyhole mouth. The characteristic frequencies are equal to 0.5-4 kHz. Since plasma plume absorbs and refracts laser radiation, plasma oscillations modulate the laser beam before it reaches the workpiece. In this work temporary electron densities and temperatures are determined in the peaks of plasma bursts during welding with a continuous wave CO2 laser. It has been found that during strong bursts the plasma plume over the keyhole consists of metal vapour only, being not diluted by the shielding gas. As expected the values of electron density are about two times higher in peaks than their time-averaged values. Since the plasma absorption coefficient scales as ~N2e/T3/2 (for CO2 laser radiation) the results show that the power of the laser beam reaching the metal surface is modulated by the plasma plume oscillations. The attenuation factor equals 4-6% of the laser power but it is expected that it is doubled by the refraction effect. The results, together with the analysis of the colour pictures from streak camera, allow also interpretation of the dynamics of the plasma plume.

  2. The application of laser plasma in ophthalmology

    International Nuclear Information System (INIS)

    He Yujiang; Luo Le; Sun Yabing

    2000-01-01

    The production and development of laser plasma are introduced, and the contribution of laser biomedicine and laser plasma technology to ophthalmology is analyzed. The latest three progresses (laser photocoagulation, photo-refractive keratotomy and laser iridectomy) of laser plasma applications in ophthalmology are presented

  3. OUTCOMES AFTER LASER VERSUS COMBINED LASER AND BEVACIZUMAB TREATMENT FOR TYPE 1 RETINOPATHY OF PREMATURITY IN ZONE I.

    Science.gov (United States)

    Yoon, Je Moon; Shin, Dong Hoon; Kim, Sang Jin; Ham, Don-Il; Kang, Se Woong; Chang, Yun Sil; Park, Won Soon

    2017-01-01

    To investigate the anatomical and refractive outcomes in patients with Type 1 retinopathy of prematurity in Zone I. The medical records of 101 eyes of 51 consecutive infants with Type 1 retinopathy of prematurity in Zone I were analyzed. Infants were treated by conventional laser photocoagulation (Group I), combined intravitreal bevacizumab injection and Zone I sparing laser (Group II), or intravitreal bevacizumab with deferred laser treatment (Group III). The proportion of unfavorable anatomical outcomes including retinal fold, disc dragging, retrolental tissue obscuring the view of the posterior pole, retinal detachment, and early refractive errors were compared among the three groups. The mean gestational age at birth and the birth weight of all 51 infants were 24.3 ± 1.1 weeks and 646 ± 143 g, respectively. In Group I, an unfavorable anatomical outcome was observed in 10 of 44 eyes (22.7%). In contrast, in Groups II and III, all eyes showed favorable anatomical outcomes without reactivation or retreatment. The refractive error was less myopic in Group III than in Groups I and II (spherical equivalent of -4.62 ± 4.00 D in Group I, -5.53 ± 2.21 D in Group II, and -1.40 ± 2.19 D in Group III; P prematurity in Zone I, intravitreal bevacizumab with concomitant or deferred laser therapy yielded a better anatomical outcome than conventional laser therapy alone. Moreover, intravitreal bevacizumab with deferred laser treatment resulted in less myopic refractive error.

  4. Sources of medical error in refractive surgery.

    Science.gov (United States)

    Moshirfar, Majid; Simpson, Rachel G; Dave, Sonal B; Christiansen, Steven M; Edmonds, Jason N; Culbertson, William W; Pascucci, Stephen E; Sher, Neal A; Cano, David B; Trattler, William B

    2013-05-01

    To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters. Copyright 2013, SLACK Incorporated.

  5. Clinical study of the clusters of diffuse lamellar keratitis after laser corneal refractive surgery

    Directory of Open Access Journals (Sweden)

    Qing-Hong Lin

    2017-06-01

    Full Text Available AIM: To investigate the potential causes and management of the clusters of diffuse lamellar keratitis(DLKafter laser corneal refractive surgery. METHODS: The study enrolled 98 eyes(53 patientscomplicated with DLK after receiving laser in situ keratomileusis(LASIK, FS-LASIK or small-incision lenticule extraction(SMILEin our center from February 10th,2016 to February 22th,2016. They were given clinical classification treatments according to corneal layer inflammatory extent and then followed up after 1, 3, 5, 7, 10d and 1mo. RESULTS: The clusters of DLK occurred 5 times in the study period. The incidence and degree of DLK significantly decreased after changed the sterilization, surgical equipments, temperature and humidity of the operating room. There were 80 eyes(82%had stage 1 DLK, 11 eyes(11%had stage 2, 4 eyes(4%had stage 3 and 3 eyes(3%had stage 4. The incidence of DLK after FS-LASIK was 40%(79 eyes in 42 patients, that after LASIK assistant by Hastome keratome was 45%(10 eyes in 5 patients, that after SMILE was 20%(9 eyes in 6 patients. After intensive treatment, as glucocorticoid treatment and flap lifting flushing, all cases recovered within 1mo. CONCLUSION: The outbreak of DLK may be associated with the disposable item, flushing liquor, temperature and humidity of the operating room. Early diagnosis, prevention and treatment are the key of decreasing the incidence of DLK.

  6. Applying field mapping refractive beam shapers to improve holographic techniques

    Science.gov (United States)

    Laskin, Alexander; Williams, Gavin; McWilliam, Richard; Laskin, Vadim

    2012-03-01

    Performance of various holographic techniques can be essentially improved by homogenizing the intensity profile of the laser beam with using beam shaping optics, for example, the achromatic field mapping refractive beam shapers like πShaper. The operational principle of these devices presumes transformation of laser beam intensity from Gaussian to flattop one with high flatness of output wavefront, saving of beam consistency, providing collimated output beam of low divergence, high transmittance, extended depth of field, negligible residual wave aberration, and achromatic design provides capability to work with several laser sources with different wavelengths simultaneously. Applying of these beam shapers brings serious benefits to the Spatial Light Modulator based techniques like Computer Generated Holography or Dot-Matrix mastering of security holograms since uniform illumination of an SLM allows simplifying mathematical calculations and increasing predictability and reliability of the imaging results. Another example is multicolour Denisyuk holography when the achromatic πShaper provides uniform illumination of a field at various wavelengths simultaneously. This paper will describe some design basics of the field mapping refractive beam shapers and optical layouts of their applying in holographic systems. Examples of real implementations and experimental results will be presented as well.

  7. Polymer laser bio-sensors

    DEFF Research Database (Denmark)

    Kristensen, Anders; Vannahme, Christoph; Hermannsson, Pétur Gordon

    2014-01-01

    Organic dye based distributed feed-back lasers, featuring narrow linewidth and thus high quality spectral resolution, are used as highly sensitive refractive index sensors. The design, fabrication and application of the laser intra-cavity sensors are discussed....

  8. Fiber optic refractive index sensor using optofluidic anti-resonant reflecting guidance

    Science.gov (United States)

    Gao, Ran; Lu, Danfeng; Cheng, Jin; Qi, Zhi-mei

    2017-10-01

    An optofluidic anti-resonant reflecting guidance has been proposed and experimental demonstrated for the measurement of liquid refractive index. Two micro-channels were fabricated for the delivery of the liquid sample in the hollow core photonic crystal fiber by using femtosecond laser micromachining, serving as an inlet and outlet. The refractive index can be detected by using the resonant condition of the Fabry-Perot resonator, which is interrogated through the wavelength shift and of the lossy dip in the transmission spectrum. The experimental results show that the sensitivity of up to 1328 nm/RIU is achieved for the refractive index in the range from 1.345 to 1.363 RIU, respectively. The proposed sensor appears to have potential applications of precise measurement in chemistry, medicine, and biology.

  9. Optimization of torque on an optically driven micromotor by manipulation of the index of refraction

    Science.gov (United States)

    Wing, Frank M., III; Mahajan, Satish; Collett, Walter

    2004-12-01

    Since the 1970"s, the focused laser beam has become a familiar tool to manipulate neutral, dielectric micro-objects. A number of authors, including Higurashi and Gauthier, have described the effects of radiation pressure from laser light on microrotors. Collett, et al. developed a wave, rather than a ray optic, approach in the calculation of such forces on a microrotor for the first time. This paper describes a modification to the design of a laser driven, radiation pressure microrotor, intended to improve the optically generated torque. Employing the wave approach, the electric and magnetic fields in the vicinity of the rotor are calculated using the finite difference time domain (FDTD) method, which takes into account the wave nature of the incident light. Forces are calculated from the application of Maxwell"s stress tensor over the surfaces of the rotor. Results indicate a significant increase in torque when the index of refraction of the microrotor is changed from a single value to an inhomogeneous profile. The optical fiber industry has successfully employed a variation in the index of refraction across the cross section of a fiber for the purpose of increasing the efficiency of light transmission. Therefore, it is hoped that various fabrication methods can be utilized for causing desired changes in the index of refraction of an optically driven microrotor. Various profiles of the index of refraction inside a microrotor are considered for optimization of torque. Simulation methodology and results of torque on a microrotor for various profiles of the index of refraction are presented. Guidelines for improvised fabrication of efficient microrotors may then be obtained from these profiles.

  10. Robust optimization of the laser induced damage threshold of dielectric mirrors for high power lasers.

    Science.gov (United States)

    Chorel, Marine; Lanternier, Thomas; Lavastre, Éric; Bonod, Nicolas; Bousquet, Bruno; Néauport, Jérôme

    2018-04-30

    We report on a numerical optimization of the laser induced damage threshold of multi-dielectric high reflection mirrors in the sub-picosecond regime. We highlight the interplay between the electric field distribution, refractive index and intrinsic laser induced damage threshold of the materials on the overall laser induced damage threshold (LIDT) of the multilayer. We describe an optimization method of the multilayer that minimizes the field enhancement in high refractive index materials while preserving a near perfect reflectivity. This method yields a significant improvement of the damage resistance since a maximum increase of 40% can be achieved on the overall LIDT of the multilayer.

  11. An investigation of matched index of refraction technique and its application in optical measurements of fluid flow

    Science.gov (United States)

    Amini, Noushin; Hassan, Yassin A.

    2012-12-01

    Optical distortions caused by non-uniformities of the refractive index within the measurement volume is a major impediment for all laser diagnostic imaging techniques applied in experimental fluid dynamic studies. Matching the refractive indices of the working fluid and the test section walls and interfaces provides an effective solution to this problem. The experimental set-ups designed to be used along with laser imaging techniques are typically constructed of transparent solid materials. In this investigation, different types of aqueous salt solutions and various organic fluids are studied for refractive index matching with acrylic and fused quartz, which are commonly used in construction of the test sections. One aqueous CaCl2·2H2O solution (63 % by weight) and two organic fluids, Dibutyl Phthalate and P-Cymene, are suggested for refractive index matching with fused quartz and acrylic, respectively. Moreover, the temperature dependence of the refractive indices of these fluids is investigated, and the Thermooptic Constant is calculated for each fluid. Finally, the fluid viscosity for different shear rates is measured as a function of temperature and is applied to characterize the physical behavior of the proposed fluids.

  12. Effect of intense high-frequency laser field on the linear and nonlinear intersubband optical absorption coefficients and refractive index changes in a parabolic quantum well under the applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Yesilgul, U., E-mail: uyesilgul@cumhuriyet.edu.tr [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Ungan, F. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sakiroglu, S. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey); Mora-Ramos, M.E. [Facultad de Ciencias Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, C.P. 62209 Cuernavaca, Morelos (Mexico); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Kasapoglu, E.; Sarı, H. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sökmen, I. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey)

    2014-01-15

    The effects of the intense high-frequency laser field on the optical absorption coefficients and the refractive index changes in a GaAs/GaAlAs parabolic quantum well under the applied electric field have been investigated theoretically. The electron energy levels and the envelope wave functions of the parabolic quantum well are calculated within the effective mass approximation. Analytical expressions for optical properties are obtained using the compact density-matrix approach. The numerical results show that the intense high-frequency laser field has a large effect on the optical characteristics of these structures. Also we can observe that the refractive index and absorption coefficient changes are very sensitive to the electric field in large dimension wells. Thus, this result gives a new degree of freedom in the optoelectronic device applications. -- Highlights: • ILF has a large effect on the optical properties of parabolic quantum wells. • The total absorption coefficients increase as the ILF increases. • The RICs increase as the ILF increases.

  13. Interferometric investigation and simulation of refractive index in glass matrixes containing nanoparticles of varying sizes

    Energy Technology Data Exchange (ETDEWEB)

    Feeney, Michael Gerard; Ince, Rabia; Yukselici, Mehmet Hikmet; Allahverdi, Cagdas

    2011-07-01

    The relationship between refractive index and nanoparticle radii of cadmium selenide (CdSe) nanoparticles embedded within glass matrixes was investigated experimentally and by simulations. A homemade automated Michelson interferometer arrangement employing a rotating table and a He-Ne laser source at a wavelength of 632.8 nm determined the refractive index versus nanoparticle radii of embedded cadmium selenide (CdSe) nanoparticles. The refractive index was found to decrease linearly with nanoparticle radius increase. However, one sample showed a step increase in refractive index; on spectroscopic analysis, it was found that its resonant wavelength matched that of the He-Ne source wavelength. The simulations showed that two conditions caused the step increase in refractive index: low plasma frequency and matched sample and source resonances. This simple interferometer setup defines a new method of determining the radii of nanoparticles embedded in substrates and enables refractive index tailoring by modification of exact annealing conditions.

  14. Use of the Femtosecond Lasers in Ophthalmology

    Directory of Open Access Journals (Sweden)

    Roszkowska Anna M

    2018-01-01

    Full Text Available Femtosecond laser (FSL is an infrared laser with a wavelength of 1053 nm. FS laser works producing photodisruption or photoionization of the optically transparent tissue such as cornea. Currently FS lasers have a wide range of applications in ophthalmic surgery. They are used above all in corneal surgery in refractive procedures and keratoplasty, and recently in cataract surgery. The use of the FSL in corneal refractive surgery includes LASIK flap creation, astigmatic keratotomy, Femtosecond Lenticule Extraction (FLEx, Small Incision Lenticule Extraction (SMILE and channels creation for implantation of the intrastromal corneal rings. As to the corneal grafting, the FS lasers are used in laser-assisted anterior and posterior lamellar keratoplasty and customized trephination in the penetrating keratoplasty. FS Laser Assisted Cataract Surgery (FLACS includes capsulorrhexis and nuclear fragmentation that enhance safety and efficacy of the procedure.

  15. Use of the Femtosecond Lasers in Ophthalmology

    Science.gov (United States)

    Roszkowska, Anna M.; Urso, Mario; Signorino, Alberto; Aragona, Pasquale

    2018-01-01

    Femtosecond laser (FSL) is an infrared laser with a wavelength of 1053 nm. FS laser works producing photodisruption or photoionization of the optically transparent tissue such as cornea. Currently FS lasers have a wide range of applications in ophthalmic surgery. They are used above all in corneal surgery in refractive procedures and keratoplasty, and recently in cataract surgery. The use of the FSL in corneal refractive surgery includes LASIK flap creation, astigmatic keratotomy, Femtosecond Lenticule Extraction (FLEx), Small Incision Lenticule Extraction (SMILE) and channels creation for implantation of the intrastromal corneal rings. As to the corneal grafting, the FS lasers are used in laser-assisted anterior and posterior lamellar keratoplasty and customized trephination in the penetrating keratoplasty. FS Laser Assisted Cataract Surgery (FLACS) includes capsulorrhexis and nuclear fragmentation that enhance safety and efficacy of the procedure.

  16. Cladding-like waveguide fabricated by cooperation of ultrafast laser writing and ion irradiation: characterization and laser generation.

    Science.gov (United States)

    Lv, Jinman; Shang, Zhen; Tan, Yang; Vázquez de Aldana, Javier Rodríguez; Chen, Feng

    2017-08-07

    We report the surface cladding-like waveguide fabricated by the cooperation of the ultrafast laser writing and the ion irradiation. The ultrafast laser writes tracks near the surface of the Nd:YAG crystal, constructing a semi-circle columnar structure with a decreased refractive index of - 0.00208. Then, the Nd:YAG crystal is irradiated by the Carbon ion beam, forming an enhanced-well in the semi-circle columnar with an increased refractive index of + 0.0024. Tracks and the enhanced-well consisted a surface cladding-like waveguide. Utilizing this cladding-like waveguide as the gain medium for the waveguide lasing, optimized characterizations were observed compared with the monolayer waveguide. This work demonstrates the refractive index of the Nd:YAG crystal can be well tailored by the cooperation of the ultrafast laser writing and the ion irradiation, which provides an convenient way to fabricate the complex and multilayered photonics devices.

  17. Investigation of retinal damage during refractive eye surgery

    Science.gov (United States)

    Schumacher, S.; Sander, M.; Dopke, C.; Grone, A.; Ertmer, W.; Lubatschowski, H.

    2005-04-01

    Ultrashort laser pulses are increasingly used in refractive eye surgery to cut inside transparent corneal tissue. This is exploited by the fs-LASIK procedure which affords the opportunity to correct ametropia without any mechanical effects. The cutting process is caused by the optical breakdown occurring in the laser focus. During this process only a certain amount of the pulse energy is deposited into the tissue. The remaining pulse energy propagates further through the eye and interacts with the retina and the strong absorbing tissue layers behind. Therefore this investigation shall clarify if the intensity of the remaining laser pulse and the resulting temperature field can damage the retina and the surrounding tissue. Threshold values of the retinal tissue and theoretical calculations of the temperature field will be presented.

  18. Straylight before and after hyperopic laser in situ keratomileusis or laser-assisted subepithelial keratectomy

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; van der Linden, Jan Willem; van der Meulen, Ivanka J. E.; Nieuwendaal, Carla P.; Mourits, Maarten P.; van den Berg, Thomas J. T. P.

    2010-01-01

    PURPOSE To compare straylight values before and 3 months after hyperopic laser in situ keratomileusis (LASIK) or laser-assisted subepithelial keratectomy (LASEK) and determine the cause of any change SETTING Private refractive surgery clinic, Driebergen, The Netherlands DESIGN Comparative case

  19. Straylight measurements in laser in situ keratomileusis and laser-assisted subepithelial keratectomy for myopia

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; van der Linden, Jan Willem; van der Meulen, Ivanka; Nieuwendaal, Carla; van den Berg, Tom

    2010-01-01

    PURPOSE: To compare straylight values before and 3 months after laser in situ keratomileusis (LASIK) and laser-assisted subepithelial keratectomy (LASEK) and to analyze the causes of any change. SETTING: Private refractive surgery clinic, Driebergen, The Netherlands. METHODS: Straylight was measured

  20. Modification of Low Refractive Index Polycarbonate for High Refractive Index Applications

    Directory of Open Access Journals (Sweden)

    Gunjan Suri

    2009-01-01

    Full Text Available Polycarbonates and polythiourethanes are the most popular materials in use today, for optical applications. Polycarbonates are of two types which fall in the category of low refractive index and medium refractive index. The present paper describes the conversion of low refractive index polycarbonates into high refractive index material by the use of a high refractive index monomer, polythiol, as an additive. Novel polycarbonates, where the properties of refractive index and Abbe number can be tailor made, have been obtained. Thermal studies and refractive index determination indicate the formation of a new polymer with improved properties and suitable for optical applications.

  1. Temperature independent refractive index measurement using a fiber Bragg grating on abrupt tapered tip

    Science.gov (United States)

    Gomes, André D.; Silveira, Beatriz; Warren-Smith, Stephen C.; Becker, Martin; Rothhardt, Manfred; Frazão, Orlando

    2018-05-01

    A fiber Bragg grating was inscribed in an abrupt fiber taper using a femtosecond laser and phase-mask interferometer. The abrupt taper transition allows to excite a broad range of guided modes with different effective refractive indices that are reflected at different wavelengths according to Bragg's law. The multimode-Bragg reflection expands over 30 nm in the telecom-C-band. This corresponds to a mode-field overlap of up to 30% outside of the fiber, making the device suitable for evanescent field sensing. Refractive index and temperature measurements are performed for different reflection peaks. Temperature independent refractive index measurements are achieved by considering the difference between the wavelength shifts of two measured reflection peaks. A minimum refractive index sensitivity of 16 ± 1 nm/RIU was obtained in a low refractive index regime (1.3475-1.3720) with low influence of temperature (-0.32 ± 0.06 pm/°C). The cross sensitivity for this structure is 2.0 × 10-5 RIU/°C. The potential for simultaneous measurement of refractive index and temperature is also studied.

  2. Study on Brewster angle thin film polarizer using hafnia-silica mixture as high-refractive-index material

    Science.gov (United States)

    Xu, Nuo; Zhu, Meiping; Sun, Jian; Chai, Yingjie; Kui, Yi; Zhao, Yuanan; Shao, Jianda

    2018-02-01

    Two kinds of polarizer coatings were prepared by electron beam evaporation, using HfO2-SiO2 mixture and HfO2 as the high-refractive-index materials, respectively. The HfO2-SiO2 mixture layer was implemented by coevaporating SiO2 and metal Hf, the materials were deposited at an oxygen atmosphere to achieve stoichiometric coatings. The certain HfO2 and SiO2 content ratio is controlled by adjusting the deposition rate of HfO2 and SiO2 using individual quartz crystal monitor. The spectral performance, surface and interfacial properties, as well as the laser-induced damage performance were studied and compared. Comparing with polarizer coating using HfO2 as high-refractive-index material, the polarizer coating using HfO2-SiO2 mixture as high-refractive-index material shows better performance with broader polarizing bandwidth, lower surface roughness, better interfacial property while maintaining high laser-induced damage threshold.

  3. Precision measurement of refractive index of air based on laser synthetic wavelength interferometry with Edlén equation estimation.

    Science.gov (United States)

    Yan, Liping; Chen, Benyong; Zhang, Enzheng; Zhang, Shihua; Yang, Ye

    2015-08-01

    A novel method for the precision measurement of refractive index of air (n(air)) based on the combining of the laser synthetic wavelength interferometry with the Edlén equation estimation is proposed. First, a n(air_e) is calculated from the modified Edlén equation according to environmental parameters measured by low precision sensors with an uncertainty of 10(-6). Second, a unique integral fringe number N corresponding to n(air) is determined based on the calculated n(air_e). Then, a fractional fringe ε corresponding to n(air) with high accuracy can be obtained according to the principle of fringe subdivision of laser synthetic wavelength interferometry. Finally, high accurate measurement of n(air) is achieved according to the determined fringes N and ε. The merit of the proposed method is that it not only solves the problem of the measurement accuracy of n(air) being limited by the accuracies of environmental sensors, but also avoids adopting complicated vacuum pumping to measure the integral fringe N in the method of conventional laser interferometry. To verify the feasibility of the proposed method, comparison experiments with Edlén equations in short time and in long time were performed. Experimental results show that the measurement accuracy of n(air) is better than 2.5 × 10(-8) in short time tests and 6.2 × 10(-8) in long time tests.

  4. Reflection-based fibre-optic refractive index sensor using surface plasmon resonance

    Czech Academy of Sciences Publication Activity Database

    Hlubina, P.; Kadulová, M.; Ciprian, D.; Sobota, Jaroslav

    2014-01-01

    Roč. 9, August 19 (2014), 14033:1-5 ISSN 1990-2573 R&D Projects: GA MŠk(CZ) LO1212 Keywords : surface plasmon resonance * fibre-optic sensor * spectral interrogation technique * aqueous solutions of ethanol * refractive index Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.231, year: 2014

  5. [Advantages and disadvantages of femtosecond laser assisted LASIK and SMILE].

    Science.gov (United States)

    Zhang, F J; Sun, M S

    2018-01-11

    With the development of excimer laser and femtosecond laser equipment, application of diversified and customized surgical decision in modern corneal refractive surgery has been an inevitable trend. However, how to make a personalized decision with an accurate surgical design to achieve better visual quality becomes the main focus in clinical applications. Small-incision lenticule extraction (SMILE) and femtosecond assisted laser in situ keratomileusis (FS-LASIK) have been commonly acknowledged as the mainstream of corneal refractive surgery for ametropia correction nowadays. Both methods have been verified by clinical practice for many years. This article compares and elaborates the different characteristics with advantages and disadvantages of the two methods so as to provide some reasonable treatment options for refractive surgery. (Chin J Ophthalmol, 2018, 54: 7-10) .

  6. Guiding flying-spot laser transepithelial phototherapeutic keratectomy with optical coherence tomography.

    Science.gov (United States)

    Li, Yan; Yokogawa, Hideaki; Tang, Maolong; Chamberlain, Winston; Zhang, Xinbo; Huang, David

    2017-04-01

    To analyze transepithelial phototherapeutic keratectomy (PTK) results using optical coherence tomography (OCT) and develop a model to guide the laser dioptric and depth settings. Casey Eye Institute, Portland, Oregon, USA. Prospective nonrandomized case series. Patients with superficial corneal opacities and irregularities had transepithelial PTK with a flying-spot excimer laser by combining wide-zone myopic and hyperopic astigmatic ablations. Optical coherence tomography was used to calculate corneal epithelial lenticular masking effects, guide refractive laser settings, and measure opacity removal. The laser ablation efficiency and the refractive outcome were investigated using multivariate linear regression models. Twenty-six eyes of 20 patients received PTK to remove opacities and irregular astigmatism due to scar, dystrophy, radial keratotomy, or previous corneal surgeries. The uncorrected distance visual acuity and corrected distance visual acuity were significantly improved (P laser ablation depths were 31.3% (myopic ablation) and 63.0% (hyperopic ablation) deeper than the manufacturer's nomogram. The spherical equivalent of the corneal epithelial lenticular masking effect was 0.73 diopter ± 0.61 (SD). The refractive outcome highly correlated to the laser settings and epithelial lenticular masking effect (Pearson R = 0.96, P < .01). The ablation rate of granular dystrophy opacities appeared to be slower. Smoothing ablation under masking fluid was needed to prevent focal steep islands in these cases. The OCT-measured ablation depth efficiency could guide opacity removal. The corneal epithelial lenticular masking effect could refine the spherical refractive nomogram to achieve a better refractive outcome after transepithelial ablation. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Analytic models for beam propagation and far-field patterns in slab and bow-tie x-ray lasers

    International Nuclear Information System (INIS)

    Chandler, E.A.

    1994-06-01

    Simplified analytic models for beam propagation in slab and bow-tie x-ray lasers yield convenient expressions that provide both a framework for guidance in computer modeling and useful approximates for experimenters. In unrefracted bow-tie lasers, the laser shape in conjunction with the nearly-exponential weighting of rays according to their length produces a small effective aperture for the signal. We develop an analytic expression for the aperture and the properties of the far-field signal. Similarly, we develop the view that the far-field pattern of refractive slab lasers is the result of effective apertures that are created by the interplay of refraction and exponential amplification. We present expressions for the size of this aperture as a function of laser parameters as well as for the intensity and position of the far-field lineout. This analysis also yields conditions for the refraction limit in slab lasers and an estimate for the signal loss due to refraction

  8. Electrons and atoms in intense laser fields

    International Nuclear Information System (INIS)

    Davidovich, L.

    1982-11-01

    Several non-linear effects that show up when electrons and atoms interact with strong laser fields are considered. Thomson scattering, electron potential scattering in the presence of a laser beam, atomic ionization by strong laser fields, the refraction of electrons by laser beams and the Kapitza-Dirac effect are discussed. (Author) [pt

  9. Electrons and atoms in intense laser fields

    International Nuclear Information System (INIS)

    Davidovich, L.

    1982-01-01

    Several non-linear effects that show up when electrons and atoms interact with strong laser fields are considered. Thomson scattering, electron potential scattering in the presence of a laser beam, atomic ionization by strong laser fields, the refraction of electrons by laser beams and the Kapitza-Dirac effect are discussed. (Author) [pt

  10. Diffractive-refractive optics: (+,-,-,+) X-ray crystal monochromator with harmonics separation

    Czech Academy of Sciences Publication Activity Database

    Hrdý, Jaromír; Mikulík, P.; Oberta, Peter

    2011-01-01

    Roč. 18, č. 2 (2011), s. 299-301 ISSN 0909-0495 R&D Projects: GA MPO FR-TI1/412 Institutional research plan: CEZ:AV0Z10100522 Keywords : diffractive-refractive optics * x-ray synchrotron radiation monochromator * x-ray crystal monochromator * harmonics separation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.726, year: 2011

  11. Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia

    DEFF Research Database (Denmark)

    Vestergaard, Anders; Justesen, Birgitte Larsen; Melsen, Charlotte

    Title: Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia. Vestergaard A., Justesen B., Melsen C., Lyhne N., Department of Ophthal......Title: Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia. Vestergaard A., Justesen B., Melsen C., Lyhne N., Department...... predictability, efficacy and safety after femtosecond LASIK (FS-LASIK) with ReLEx. Setting: Department of Ophthalmology, Odense University Hospital, Denmark. Methods: Retrospective study of results after FS-LASIK and ReLEx (including ReLEx flex, ReLEx pseudo-smile, and ReLEx smile). In total, 228 eyes were...... treated with FS-LASIK and 83 eyes with ReLEx, at the Department of Ophthalmology, Odense University Hospital in the period of April to November 2011. Only otherwise healthy myopic eyes with up to 3.00 D of astigmatism and with CDVA ≤ 0.30 (logMAR) before surgery were included in this study. FS-LASIK flaps...

  12. Laser diagnostics for picosecond e-beams

    International Nuclear Information System (INIS)

    Pogorelsky, I.; Ben-Zvi, I.

    1992-01-01

    We propose a novel approach to picosecond e-bunch/laser pulse synchronization and spatial alignment based upon refraction and reflection of a laser beam on a plasma column created by relativistic electrons traveling through a gas or solid optical material. The technique may be used in laser accelerators and for general subpicosecond e-beam diagnostics

  13. Comparison of objective refraction in darkness to cycloplegic refraction: a pilot study.

    Science.gov (United States)

    Vasudevan, Balamurali; Ciuffreda, Kenneth J; Meehan, Kelly; Grk, Dejana; Cox, Misty

    2016-03-01

    The aim was to assess non-cycloplegic objective refraction in darkness using an open-field auto-refractor, and furthermore to compare it with distance cycloplegic subjective refraction and distance cycloplegic retinoscopy in the light, in children and young adults. Twenty-three, visually-normal, young-adults (46 eyes) ages 23 to 31 years, and five children (10 eyes) ages five to 12 years, participated in the study. The spherical component of their refraction ranged from -2.25 D to +3.75 D with a mean of +1.80 D, and a mean cylinder of -0.70 D. Three techniques were used to assess refractive error. An objective measure of the non-cycloplegic refractive state was obtained using an open-field autorefractor (WAM-5500) after five minutes in the dark to allow for dissipation of accommodative transients and relaxation of accommodation. In addition, both distance retinoscopy and subjective distance refraction were performed following cycloplegia (Cyclopentolate, 1%) using conventional clinical procedures. All measurements were obtained on the same day within a single session. The spherical component of the refraction was compared among the three techniques in both the children and adults. There was no significant difference in spherical refraction among the three techniques: non-cycloplegic objective refraction in the dark, distance cycloplegic retinoscopy and distance cycloplegic subjective refraction, in either the adults [F(2, 137) = 0.79, p = 0.45] or the children [F(2, 27) = 0.47, p = 0.62]. Mean difference in the spherical component between refraction in the dark and the cycloplegic distance retinoscopy was -0.34 D (r = 0.89) in the adults and +0.14 D (r = 0.96) in the children. The mean difference in spherical component between refraction in the dark and the cycloplegic distance subjective refraction was -0.25 D (r = 0.92) in the adults and -0.05 D (r = 0.95) in the children. Comparison of the spherical refractive component between the three techniques was not

  14. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  15. Refractive index of r-cut sapphire under shock pressure range 5 to 65 GPa

    International Nuclear Information System (INIS)

    Cao, Xiuxia; Li, Jiabo; Li, Jun; Li, Xuhai; Xu, Liang; Wang, Yuan; Zhu, Wenjun; Meng, Chuanmin; Zhou, Xianming

    2014-01-01

    High-pressure refractive index of optical window materials not only can provide information on electronic polarizability and band-gap structure, but also is important for velocity correction in particle-velocity measurement with laser interferometers. In this work, the refractive index of r-cut sapphire window at 1550 nm wavelength was measured under shock pressures of 5–65 GPa. The refractive index (n) decreases linearly with increasing shock density (ρ) for shock stress above the Hugoniot elastic limit (HEL): n = 2.0485 (± 0.0197) − 0.0729 (± 0.0043)ρ, while n remains nearly a constant for elastic shocks. This behavior is attributed to the transition from elastic (below HEL) to heterogeneous plastic deformation (above HEL). Based on the obtained refractive index-density relationship, polarizability of the shocked sapphire was also obtained

  16. Liquid Atomization Induced by Pulse Laser Reflection underneath Liquid Surface

    Science.gov (United States)

    Utsunomiya, Yuji; Kajiwara, Takashi; Nishiyama, Takashi; Nagayama, Kunihito; Kubota, Shiro; Nakahara, Motonao

    2009-05-01

    We observed a novel effect of pulse laser reflection at the interface between transparent materials with different refractive indices. The electric field intensity doubles when a laser beam is completely reflected from a material with a higher refractive index to a material with a lower index. This effect appreciably reduces pulse laser ablation threshold of transparent materials. We performed experiments to observe the entire ablation process for laser incidence on the water-air interface using pulse laser shadowgraphy with high-resolution film; the minimum laser fluence for laser ablation at the water-air interface was approximately 12-16 J/cm2. We confirmed that this laser ablation occurs only when the laser beam is incident on the water-air interface from water. Many slender liquid ligaments extend like a milk crown and seem to be atomized at the tip. Their detailed structures can be resolved only by pulse laser photography using high-resolution film.

  17. Pulsed UV laser technologies for ophthalmic surgery

    International Nuclear Information System (INIS)

    Razhev, A M; Bagayev, S N; Churkin, D S; Kargapol’tsev, E S; Chernykh, V V; Iskakov, I A; Ermakova, O V

    2017-01-01

    The paper provides an overview of the results of multiyear joint researches of team of collaborators of Institute of Laser Physics SB RAS together with NF IRTC “Eye Microsurgery” for the period from 1988 to the present, in which were first proposed and experimentally realized laser medical technologies for correction of refractive errors of known today as LASIK, the treatment of ophthalmic herpes and open-angle glaucoma. It is proposed to carry out operations for the correction of refractive errors the use of UV excimer KrCl laser with a wavelength of 222 nm. The same laser emission is the most suitable for the treatment of ophthalmic herpes, because it has a high clinical effect, combined with many years of absence of recrudescence. A minimally invasive technique of glaucoma operations using excimer XeCl laser (λ=308 nm) is developed. Its wavelength allows perform all stages of glaucoma operations, while the laser head itself has high stability and lifetime, will significantly reduce operating costs, compared with other types of lasers. (paper)

  18. MANAGEMENT OF RESIDUAL REFRACTIVE ERROR AFTER CATARACT PHACOEMULSIFICATION. PART 2. INTRAOCULAR APPROACHES

    Directory of Open Access Journals (Sweden)

    K. B. Pershin

    2017-01-01

    Full Text Available The review presents an  analysis  of the  literature  data  on  the  methods of surgical  correction of residual  refractive  error after cataract phacoemulsification. Keratorefractive and intraocular approaches are  considered in details.  A comparison of the  efficacy and  safet y  of different groups   of methods on  the  example  of comparative studies is given.  Historically earlier  keratorefractive methods (laser  vision correction with LASIK and  PRK techniques on intact  eyes,  LASIK after  implantation  of multifocal  IOLs and arcuate keratotomy  after  phaco  are  indicated  for  the  correction of astigmatic refractive  error and  a small  spherical refractive error. Intraocular methods, including the  replacement of the  IOL  and  «piggyback» IOLs implantation  are  used  to  correct a large spherical refractive error. The introduction  of new  technology, the  implantation  of light-adjustable  IOLs, will  expand  the  existing evidence  and provide greater predictabilit y and efficiency of the  method  of correction of residual  refractive error.

  19. Noncontact Optical Fiber Sensor for Measuring the Refractive Index of Liquids

    Directory of Open Access Journals (Sweden)

    R. Selvas-Aguilar

    2016-01-01

    Full Text Available A noncontact optical fiber sensor for measuring the refractive index of transparent liquids is proposed. It operates by calculating the path of a focused laser beam at 635 nm that travels across the boundaries of a liquid sample. The optical power Fresnel reflections are detected and, subsequently, the refractive index is determined as the ratio between the traveled beam paths when the liquid is deposited versus a reference without the liquid sample. Additionally, a mathematical analysis of the geometrical case is included. The theoretical data from our sensor are in good agreement with the experimental results. The resolution achieved by the sensor is better than 10−3 RIU.

  20. Measurement of large nonlinear refractive index of natural pigment extracted from Hibiscus rosa-sinensis leaves with a low power CW laser and by spatial self-phase modulation technique

    Science.gov (United States)

    Biswas, S.; Kumbhakar, P.

    2017-02-01

    We have reported here, for the first time, to the best of our knowledge, a high nonlinear refractive index (n2e) of a natural pigment extracted from Hibiscus rosa-sinensis leaves by using spatial self-phase modulation technique (SSPM) with a low power CW He-Ne laser radiation at 632.8 nm. It is found by UV-Vis absorption spectroscopic analysis that chlrophyll-a, chlrophyll-b and carotenoid are present in the pigment extract with 56%, 25% and 19%, respectively. The photoluminescence (PL) emission characteristics of the extracted samples have also been measured at room temperature as well as in the temperature range of 283-333 K to investigate the effect of temperature on luminescent properties of the sample. By analyzing the SSPM experimental data, the nonlinear refractive index value of pigment extract has been determined to be 3.5 × 10- 5 cm2/W. The large nonlinear refractive index has been assigned due to asymmetrical structure, molecular reorientation and thermally induced nonlinearity in the sample. The presented results might open new avenues for the green and economical technique of syntheses of organic dyes with such a large nonlinear optical property.

  1. Applications of Optical Interferometer Techniques for Precision Measurements of Changes in Temperature, Growth and Refractive Index of Materials

    Directory of Open Access Journals (Sweden)

    Rami Reddy Bommareddi

    2014-05-01

    Full Text Available Optical metrology techniques used to measure changes in thickness; temperature and refractive index are surveyed. Optical heterodyne detection principle and its applications for precision measurements of changes in thickness and temperature are discussed. Theoretical formulations are developed to estimate crystal growth rate, surface roughness and laser cooling/heating of solids. Applications of Michelson and Mach-Zehnder interferometers to measure temperature changes in laser heating of solids are described. A Mach-Zehnder interferometer is used to measure refractive index and concentration variations of solutions in crystal growth experiments. Additionally, fluorescence lifetime sensing and fluorescence ratio method are described for temperature measurement. For all the above techniques, uncertainty calculations are included.

  2. The New Zealand cataract and refractive surgery survey 1997/1998.

    Science.gov (United States)

    Elder, M; Tarr, K; Leaming, D

    2000-04-01

    This study documents the current practice for cataract and refractive surgery in New Zealand. A postal questionnaire was distributed in late 1997 to all consultant members of the Ophthalmological Society of New Zealand that were resident in the country at that time. Most questions were identical to the 1997 survey of the American Society of Cataract and Refraction Surgeons (ASCRS) to enable a comparison. There were 98 returns from 101 surveys distributed. Of the returns, 72 performed cataract surgery, 23 performed PRK and 11 performed LASIK. ASCRS members did more refractive surgery than did New Zealanders: 28 versus 1% of 1-5 RK per month, 7 versus 1% of 1-2 clear lens extractions per month and 85 versus 51% had access to an excimer laser. For cataract surgery, ASCRS members used more topical anaesthesia (30 vs 5.5%), used no sutures more often (73 vs 51%), used more preoperative antibiotics (76 vs 26%) and used fewer injections of antibiotic/steroids (38 vs 61%). Otherwise the two groups were broadly similar.

  3. Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery.

    Science.gov (United States)

    Camps, Vicente J; Miret, Juan J; García, Celia; Tolosa, Angel; Piñero, David P

    2018-04-01

    To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann-Shack sensor were used. In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and -4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at -2.50 D in the rest. The Mplus showed a focus of -4.50 and -3.00 D for the 3- and 4-mm pupil, respectively. The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies. [J Refract Surg. 2018;34(4):222-227.]. Copyright 2018, SLACK Incorporated.

  4. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    International Nuclear Information System (INIS)

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  5. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    Energy Technology Data Exchange (ETDEWEB)

    Ungan, F., E-mail: fungan@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Restrepo, R.L. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia AA 7516, Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Facultad de Ciencias, Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Morales, A.L.; Duque, C.A. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2014-02-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications.

  6. Nonintrusive measurement of the liquid refractive index by using properties of the cuvette wall.

    Science.gov (United States)

    Xu, Ming; Ren, Junpeng; Miao, Runcai; Zhang, Zongquan

    2016-10-01

    We present a method of nonintrusive measurement of the refractive index of a liquid in a glass cuvette, which uses some optical properties of the cuvette wall and the principle of total internal reflection. By coating a transmission-scattering paint layer on the outer surface of the cuvette, we transform an incident laser beam into a transmitted scattered light. When the transmitted scattered light reaches the interface between the container wall and the liquid inside, the light beams satisfying the condition of total internal reflection are reflected to the coating layer, automatically forming a circular dark pattern that is related to the refractive index of the liquid. Based on an analytic relation between the diameter of the circular dark pattern and the refractive index of the liquid, we devised a method of in situ nonintrusive refractive index measurement. We tested the effect of several parameters on the measuring accuracy and found that the optimal thickness of the transmission-scattering layer is in the range of 50-70 μm, and the aperture of the diaphragm should be in the range of 0.7-1.0 mm. We measured the refractive indices of ethanol, Coca Cola, and red wine, and achieved an accuracy of ±3×10-4  RIU (refractive index unit).

  7. High index of refraction films for dielectric mirrors prepared by metal-organic chemical vapor deposition

    International Nuclear Information System (INIS)

    Brusasco, R.M.

    1989-01-01

    A wide variety of metal oxides with high index of refraction can be prepared by Metal-Organic Chemical Vapor Deposition. We present some recent optical and laser damage results on oxide films prepared by MOCVD which could be used in a multilayer structure for highly reflecting (HR) dielectric mirror applications. The method of preparation affects both optical properties and laser damage threshold. 10 refs., 8 figs., 4 tabs

  8. Towards a Negative Refractive Index in an Atomic System

    Science.gov (United States)

    Simmons, Zach; Brewer, Nick; Yavuz, Deniz

    2014-05-01

    The goal of our experiments is to obtain a negative index of refraction in the optical region of the spectrum using an atomic system. The concept of negative refraction, which was first predicted by Veselago more than four decades ago, has recently emerged as a very exciting field of science. Negative index materials exhibit many seemingly strange properties such as electromagnetic vectors forming a left-handed triad. A key potential application for these materials was discovered in 2000 when Pendry predicted that a slab with a negative refractive index can image objects with a resolution far better than the diffraction limit. Thus far, research in negative index materials has primarily focused on meta-materials. The fixed response and often large absorption of these engineered materials motivates our efforts to work in an atomic system. An atomic media offers the potential to be actively modified, for example by changing laser parameters, and can be tuned to cancel absorption. A doped crystal allows for high atomic densities compared to other atomic systems. So far we have identified a transition in such a material, Eu:YSO, as a candidate for these experiments and are performing spectroscopy on this material.

  9. [Results of residual ametropia correction using CIRCLE technology after femtosecond laser SMILE surgery].

    Science.gov (United States)

    Kostin, O A; Rebrikov, S V; Ovchinnikov, A I; Stepanov, A A; Takhchidi, Kh P

    to evaluate functional results of reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser in cases of regression of the refractive effect after SMILE surgery. We studied a group of post-SMILE patients. In those, who showed regression of the refractive effect at 1 year, reoperation was performed according to the CIRCLE technology and using the VisuMax femtosecond laser. The corneal flap was separated from the stromal bed and turned aside. Excimer laser ablation of the stromal bed was performed with the MEL 80 machine. The corneal flap was then placed back and rinsed from both sides. Uncorrected (UCVA) and corrected (BCVA) visual acuity as well as spherical equivalent (SE) were estimated before reoperation, on day 1, and at 1 month. After reoperation, BCVA and UCVA improved. Patient refraction became close to emmetropia. Specifically, UCVA was 0.23±0.18 at baseline (i.e. 1 year after SMILE) and 0.93±0.11 after the CIRCLE procedure (pstatistically significant - from 0.95±0.1 to 0.93±0.11 (p>0.05). Reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser provides an increase in visual acuity in case of post-SMILE regression of the refractive effect.

  10. Refractive outcome of premature infants with or without retinopathy of prematurity at 2 years of age: A prospective controlled cohort study

    Directory of Open Access Journals (Sweden)

    Ching-ju Hsieh

    2012-04-01

    Full Text Available This study evaluated the extent to which refractive morbidity is correlated to preterm birth or retinopathy of prematurity (ROP itself, or both, and examined the risk factors associated with refractive errors in a cohort of preterm infants with and without ROP compared with full-term infants. This longitudinal, prospective, controlled cohort study enrolled 109 infants, including 74 preterm and 35 full-term infants. Infants were divided into the following groups: no ROP, regressed ROP, laser-treated threshold ROP, and full-term. Cycloplegic refraction was determined at 6 and 24 months’ corrected age. Multiple regression models, analysis of variance (ANOVA with post hoc comparisons, paired t test, and the χ2 test were used for data analysis. ROP status was highly predictive of significant refractive errors in preterm infants. Eyes with laser-treated threshold ROP had significant myopia at both ages (mean spherical equivalent [MSE] in right eye at both refractions −0.72, −1.21 diopters [D], astigmatism (MSE −1.62, −1.80 D, and anisometropia (MSE 0.82, 1.02 D; ANOVA p  0.05. Thus, the persistent hyperopic status across ages in patients with regressed ROP and in patients without ROP differed significantly (paired t test p > 0.05 from that in the full-term infants, with a reduction in hypermetropia noted for the first 2 years of life (paired t test p < 0.05. The incidence and magnitude of significant refractive errors increased with severe ROP and with age. Although the emmetropization process of preterm birth, including regressed ROP and no ROP, differed from full-term birth in early infancy, we found no differences in the refractive status after 1 year in patients with regressed ROP and in patients without ROP, who were at risk of developing ametropia similar to that of full-term patients. Therefore, apart from laser-treated ROP, children with regressed ROP and without ROP can likely be observed with a verbal vision screening at 3

  11. Refractive Surgery: Malpractice Litigation Outcomes.

    Science.gov (United States)

    Custer, Benjamin L; Ballard, Steven R; Carroll, Robert B; Barnes, Scott D; Justin, Grant A

    2017-10-01

    To review data on malpractice claims related to refractive surgery to identify common allegations and injuries and financial outcomes. The WestlawNext database was reviewed for all malpractice lawsuits/settlements related to refractive eye surgery. Data evaluated included patient demographics, type of operation performed, plaintiff allegation, nature of injury, and litigation outcomes. A total of 167 cases met the inclusion criteria, of which 108 cases (64.7%) were found to be favorable and 59 cases (35.3%) unfavorable to the defendant. A total of 141 cases were tried by a jury with 108 cases (76.4%) favorable and 33 cases (23.6%) unfavorable to the defendant. Laser in situ keratomileusis was performed in 127 cases (76%). The most common allegations were negligence in treatment or surgery in 127 cases (76%) and lack of informed consent in 83 cases (49.7%). For all cases, the need for future surgery (P = 0.0001) and surgery resulting in keratoconus (P = 0.05) were more likely to favor the plaintiff. In jury verdict decisions, cases in which failure to diagnose a preoperative condition was alleged favored the defendant (P = 0.03), whereas machine malfunction (P = 0.05) favored the plaintiff. After adjustment for inflation, the overall mean award was $1,287,872. Jury verdicts and settlements led to mean awards of $1,604,801 and $826,883, respectively. Malpractice litigation in refractive surgery tends to favor the defendant. However, large awards and settlements were given in cases that were favorable to the plaintiff. The need for future surgery and surgery leading to keratoconus increased the chance of an unfavorable outcome.

  12. RADIO REFRACTIVITY RADIO REFRACTIVITY STUDY IN AKURE ...

    African Journals Online (AJOL)

    eobe

    Propagation of waves in a microwave link is through the troposphere which is the non-ionized lowest portion of the atmosphere [5]. The refractive index is defined as [5]. (1). Where εr is the dielectric constant of the troposphere. C is the speed of light and V is the phase velocity of the wave in the medium. The refractive index ...

  13. Uncorrected refractive errors.

    Science.gov (United States)

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship.

  14. Uncorrected refractive errors

    Directory of Open Access Journals (Sweden)

    Kovin S Naidoo

    2012-01-01

    Full Text Available Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC, were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR Development, Service Development and Social Entrepreneurship.

  15. Control-matched comparison of refractive and visual outcomes between small incision lenticule extraction and femtosecond laser-assisted LASIK

    Directory of Open Access Journals (Sweden)

    Kataoka T

    2018-05-01

    Full Text Available Takahiro Kataoka,1 Tomoya Nishida,1 Azusa Murata,1 Mayuka Ito,1 Naoki Isogai,1 Rie Horai,1 Takashi Kojima,1,2 Yoko Yoshida,1 Tomoaki Nakamura1 1Nagoya Eye Clinic, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan Purpose: This retrospective case-matched study aimed to compare visual and refractive outcomes between small incision lenticule extraction (SMILE and LASIK. Patients and methods: Patients who underwent SMILE (34 eyes of 23 patients or LASIK (34 eyes of 24 patients were enrolled and matched according to preoperative manifest refractive spherical equivalents. The mean preoperative manifest refractive spherical equivalent was −4.69±0.6 and −4.67±0.64 D in the SMILE and LASIK groups, respectively. The safety, efficacy, and predictability were compared 3 months after surgery. Changes in corneal refractive power from the center to peripheral points and their maintenance ratios were analyzed and compared between the two groups. Results: In the SMILE and LASIK groups, 82.4% and 85.3% of patients, respectively, achieved 20/13 or better uncorrected distance visual acuity (p=1.00. There were no eyes that lost two or more lines of corrected distance visual acuity in either group. The maintenance ratios of corneal refractive power changes at the peripheral points in the SMILE group were significantly higher than those in the LASIK group (p<0.05. Conclusion: Both groups achieved similar high efficacy and safety. SMILE surgery resulted in higher refractive power correction in the peripheral cornea than LASIK surgery. Keywords: small incision lenticule extraction, LASIK, corneal refractive power, refractive power correction efficiency, corneal topography

  16. Comparison of DLK incidence after laser in situ keratomileusis associated with two femtosecond lasers: Femto LDV and IntraLase FS60

    Directory of Open Access Journals (Sweden)

    Tomita M

    2013-07-01

    Full Text Available Minoru Tomita,1–3 Yuko Sotoyama,1 Satoshi Yukawa,1 Tadayuki Nakamura1 1Shinagawa LASIK Center, Chiyoda-ku, Tokyo, Japan; 2Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People’s Republic of China; 3Eye Can Cataract Surgery Center, Manila, Philippines Purpose: To compare the incidence of diffuse lamellar keratitis (DLK after laser in situ keratomileusis (LASIK with flap creation using the Femto LDV and IntraLase™ FS60 femtosecond lasers. Methods: A total of 818 consecutive myopic eyes had LASIK performed using either Femto LDV or IntraLase FS60 for flap creation. The same excimer laser, the Allegretto Wave® Eye-Q Laser, was used for correcting refractive errors for all patients. In the preoperative examination, uncorrected distance visual acuity, corrected distance visual acuity, and manifest refraction spherical equivalent were measured. At the postop examination, the same examinations were performed along with a slit-lamp biomicroscopic examination, and patients with DLK were classified into stages. For the statistical analysis of the DLK occurrence rate and the visual and refractive outcomes, the Mann-Whitney’s U-test was used. Results: In the Femto LDV group with 514 eyes, 42 (8.17% had DLK. In the IntraLase FS60 group with 304 eyes, 114 (37.5% had DLK. There was a statistically significant difference in the DLK incidence rate between these groups (P < 0.0001. Both groups had excellent visual and refractive outcomes. Although low levels of DLK were observed for both groups, they did not affect visual acuity. Conclusion: While there were significantly fewer incidences of low level DLK when using Femto LDV, neither femtosecond laser induced high levels of DLK, and any postoperative DLK cleared up within 1 week. Therefore, both lasers provide excellent results, with no clinical differences, and both excel at flap creation for LASIK. Keywords: LASIK, Ziemer, Femto LDV, DLK, IntraLase FS60, femtosecond laser

  17. Enhancement of optical Kerr effect in quantum-cascade lasers with multiple resonance levels.

    Science.gov (United States)

    Bai, Jing; Citrin, D S

    2008-08-18

    In this paper, we investigated the optical Kerr lensing effect in quantum-cascade lasers with multiple resonance levels. The Kerr refractive index n2 is obtained through the third-order susceptibility at the fundamental frequency chi(3)( omega; omega, omega,-omega). Resonant two-photon processes are found to have almost equal contributions to chi(3)( omega; omega, omega,-omega) as the single-photon processes, which result in the predicted enhancement of the positive nonlinear (Kerr) refractive index, and thus may enhance mode-locking of quantum-cascade lasers. Moreover, we also demonstrate an isospectral optimization strategy for further improving n2 through the band-structure design, in order to boost the multimode performance of quantum-cascade lasers. Simulation results show that the optimized stepwise multiple-quantum-well structure has n2 approximately 10-8 cm2/W, a twofold enhancement over the original flat quantum-well structure. This leads to a refractive-index change (delta)n of about 0.01, which is at the upper bound of those reported for typical Kerr medium. This stronger Kerr refractive index may be important for quantum-cascade lasers ultimately to demonstrate self-mode-locking.

  18. Laser beam propagation in atmospheric turbulence

    Science.gov (United States)

    Murty, S. S. R.

    1979-01-01

    The optical effects of atmospheric turbulence on the propagation of low power laser beams are reviewed in this paper. The optical effects are produced by the temperature fluctuations which result in fluctuations of the refractive index of air. The commonly-used models of index-of-refraction fluctuations are presented. Laser beams experience fluctuations of beam size, beam position, and intensity distribution within the beam due to refractive turbulence. Some of the observed effects are qualitatively explained by treating the turbulent atmosphere as a collection of moving gaseous lenses of various sizes. Analytical results and experimental verifications of the variance, covariance and probability distribution of intensity fluctuations in weak turbulence are presented. For stronger turbulence, a saturation of the optical scintillations is observed. The saturation of scintillations involves a progressive break-up of the beam into multiple patches; the beam loses some of its lateral coherence. Heterodyne systems operating in a turbulent atmosphere experience a loss of heterodyne signal due to the destruction of coherence.

  19. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  20. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif

    2016-09-06

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  1. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2016-01-01

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  2. [Understanding the advantages and disadvantages of femtosecond laser comprehensive applications in ophthalmology].

    Science.gov (United States)

    Xie, Li-xin; Gao, Hua

    2013-04-01

    The femtosecond (FS) laser is a novel laser technology, and is approved clinical application by FDA in 2000. FS laser initially mainly used in corneal refractive surgery to replace the mechanical microkeratome. Since the accuracy and controllability of the FS laser is very high, it shows superiority in the field of corneal refractive surgery. And with the development of the relative hard and software, FS laser is began to used in other fields of ophthalmology, such as corneal transplants, cataract surgery, as well as assisted diagnosis et al., although still have some limitations, the preliminary clinical results have been shown a very good prospects in the ophthalmology fields. Therefore, we reviewed the alternative applications, challenges and limitations, research direction in the future of FS laser, so that provide a reference and revelations for the peers.

  3. Reasons not to select patients for corneal refractive surgery Razões para recusar candidatos à cirurgia refrativa corneana

    Directory of Open Access Journals (Sweden)

    André Luiz Parolin Ribeiro

    2002-08-01

    Full Text Available Purpose: To present how the section of Refractive Surgery of the Federal University of São Paulo assesses the candidates and the reasons to indicate for corneal refractive surgery. Methods: We examined 1626 patients. Anamnesis, complete ophthalmologic examination and corneal topography were performed in all patients. The patients spontaneously seeked evaluation at the Refractive Surgery Section by telephone without a previous screening. Reasons to refuse patients for refractive surgery were previously established by the Refractive Surgery Section. Results: Based on current technology and clinical experience, 265 patients (16.29% were refused for excimer laser corneal refractive surgery. Myopia of patients who had insufficient preoperative corneal pachymetry for the laser treatment was the main cause for refusal (51 patients. Cataract (45 patients, keratoconus (31 patients, amblyopia (21 patients, hyperopia > 5 diopters and mixed astigmatism (19 patients, presbyopia (unaware ness of the need for optical correction after the procedure; 16 patients, pupillary diameter > 5mm (9 patients, single eye (9 patients, progressive myopia (8 patients, postradial keratotomy (7 patients and low ametropia (7 patients were among the reasons for the refusal. Conclusion: Candidates for excimer laser corneal refractive surgery may present risk factors that should be known in order to avoid complications.Objetivo: O objetivo deste estudo é mostrar como o setor de Cirurgia Refrativa da Escola Paulista de Medicina da Universidade Federal de São Paulo avalia seus candidatos e quais as razões para não selecioná-los para cirurgia refrativa. Métodos: Foram examinados 1626 pacientes. Anamnese, avaliação oftalmológica completa e topografia corneana foram realizadas em todos os pacientes. Os pacientes procuraram avaliação no setor de Cirurgia Refrativa espontaneamente sem triagem prévia. Resultados: Não foram selecionados 265 pacientes (16,29% para cirurgia

  4. A web-based information system for management and analysis of patient data after refractive eye surgery.

    Science.gov (United States)

    Zuberbuhler, Bruno; Galloway, Peter; Reddy, Aravind; Saldana, Manuel; Gale, Richard

    2007-12-01

    The aim was to develop a software tool for refractive surgeons using a standard user-friendly web-based interface, providing the user with a secure environment to protect large volumes of patient data. The software application was named "Internet-based refractive analysis" (IBRA), and was programmed with the computer languages PHP, HTML and JavaScript, attached to the opensource MySQL database. IBRA facilitated internationally accepted presentation methods including the stability chart, the predictability chart and the safety chart; it was able to perform vector analysis for the course of a single patient or for group data. With the integrated nomogram calculation, treatment could be customised to reduce the postoperative refractive error. Multicenter functions permitted quality-control comparisons between different surgeons and laser units.

  5. Macular lesion caused by neodymium laser

    International Nuclear Information System (INIS)

    Prammer, G.; Wiesflecker, J.; Grabner, G.

    1980-01-01

    A 21-year-old patient was struck by the pulse of a rangefinder laser (infrared laser). The massive pathologic changes on his macula are explained by the focusing effect of the refractive media. Secure location of the beam, the avoidance of reflective surfaces and absorbing screens are recommended as protective measures. (orig.) [de

  6. Optical inhomogeneity developing in flashlamp photolysis lasers

    Energy Technology Data Exchange (ETDEWEB)

    Alekhin, B V; Borovkov, V V; Brodskii, A Ya; Lazhintsev, B V; Nor-Arevian, V A; Sukhanov, L V

    1980-07-01

    The paper discusses the dynamics of optical inhomogenity developing in the active medium of a high-power flashlamp-pumped photolysis laser in inverse population storage, fast inversion suppression, and free-running lasing regimes. A chemical component of the refractive index was found in a C3F7I photolysis experiment, along with the anomalous growth of a gas refractive index.

  7. Stressed waveguides with tubular depressed-cladding inscribed in phosphate glasses by femtosecond hollow laser beams.

    Science.gov (United States)

    Long, Xuewen; Bai, Jing; Zhao, Wei; Stoian, Razvan; Hui, Rongqing; Cheng, Guanghua

    2012-08-01

    We report on the single-step fabrication of stressed optical waveguides with tubular depressed-refractive-index cladding in phosphate glasses by the use of focused femtosecond hollow laser beams. Tubelike low index regions appear under direct exposure due to material rarefaction following expansion. Strained compacted zones emerged in domains neighboring the tubular track of lower refractive index, and waveguiding occurs mainly within the tube core fabricated by the engineered femtosecond laser beam. The refractive index profile of the optical waveguide was reconstructed from the measured transmitted near-field intensity.

  8. Refractive index gradient diagnostics: analysis of different optical systems and application to COBRA ion diode

    Energy Technology Data Exchange (ETDEWEB)

    Knyazev, B A; Greenly, J B; Hammer, D A; Krastelev, E G [Cornell Univ., Ithaca, NY (United States). Laboratory of Plasma Studies; Cuneo, M E [Sandia National Laboratories, Albuquerque, NM (United States)

    1997-12-31

    Different optical system variations for refractive index gradient diagnostics with a laser beam probe have been analyzed. A `three-telescope` optical system which permits simultaneous measurement of both the laser beam centroid deflection by a bi-cell photodiode and the spatial Fourier spectrum of the deflected beam by a streak camera has been implemented on the COBRA ion diode. The dynamics of the anode plasma layer was studied with these techniques. (author). 3 figs., 8 refs.

  9. Revision to the humidity correction equation in the calculation formulae of the air refractive index based on a phase step interferometer with three frequency-stabilized lasers

    International Nuclear Information System (INIS)

    Chen, Qianghua; Zhang, Mengce; Liu, Shuaijie; He, Yongxi; Luo, Huifu; Luo, Jun; Lv, Weiwei

    2016-01-01

    At present the formulae proposed by G Boensch and E Potulski in 1998 (Boensch and Potulski 1998 Metrologia 35 133–9) are mostly used to calculate the air refractive index. However, the humidity correction equation in the formulae is derived by using the light source of a Cd lamp whose light frequency stability is poor and at a narrow temperature range, around 20 °C. So it is no longer suitable in present optical precision measurements. To solve this problem, we propose a refractive index measurement system based on phase step interferometer with three frequency stabilized lasers (532 nm, 633 nm, 780 nm), corrected coefficients of the humidity are measured and a corresponding revised humidity correction equation is acquired. Meanwhile, the application temperature range is extended from 14.6 °C to 25.0 °C. The experiment comparison results at the temperature of 22.2–23.2 °C show the accuracy by the presented equation is better than that of Boensch and Potulski. (paper)

  10. Interaction of intense laser pulses with neutral gases and preformed plasmas

    International Nuclear Information System (INIS)

    Mackinnon, A. J.; Borghesi, M.; Iwase, A.; Jones, M. W.; Willi, O.

    1998-01-01

    The interaction of a high intensity laser pulse with a neutral gas or preformed plasma has been studied over a wide range of target and laser conditions. It was found that the propagation of 2ps laser pulses (λ=1.054μm, P=5-10TW, I∼5x10 14 -1x10 14 -1x10 18 Wcm -2 ) in neutral gases with atomic densities greater than 0.001 of critical was strongly influenced by ionisation induced refraction. Preformed density channels were effective in overcoming refraction but the channel length was found to be limited by ionization induced defocusing of the prepulse

  11. Optofluidic tuning of photonic crystal band edge lasers

    DEFF Research Database (Denmark)

    Bernal, Felipe; Christiansen, Mads Brøkner; Gersborg-Hansen, Morten

    2007-01-01

    We demonstrate optofluidic tuning of polymer photonic crystal band edge lasers with an imposed rectangular symmetry. The emission wavelength depends on both lattice constant and cladding refractive index. The emission wavelength is shown to change 1 nm with a cladding refractive index change of 10......−2. The rectangular symmetry modification alters the emission characteristics of the devices and the relative emission intensities along the symmetry axes depend on cladding refractive index, suggesting a sensor concept based on detection of intensity rather than wavelength....

  12. High incidence of rainbow glare after femtosecond laser assisted-LASIK using the upgraded FS200 femtosecond laser.

    Science.gov (United States)

    Zhang, Yu; Chen, Yue-Guo

    2018-03-05

    To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was included in group A. Another consecutive series of 129 patients (255 eyes) who underwent FS-LASIK using upgraded WaveLight FS200 femtosecond laser with flap cut parameter settings changed (decreased pulse energy, spot and line separation) was included in group B. The incidence and fading time of RG, confocal microscopic image and postoperative clinical results were compared between the two groups. There were no differences between the two groups in age, baseline refraction, excimer laser ablation depth, postoperative uncorrected visual acuity and refraction. The incidence rate of RG in group A (35/255, 13.73%) was significantly higher than that in group B (4/255, 1.57%) (P  0.05).The confocal microscopic images showed wider laser spot spacing in group A than group B. The incidence of RG was significantly correlated with age and grouping (P laser with original flap cut parameter settings could increase the incidence of RG. The narrower grating size and lower pulse energy could ameliorate this side effect.

  13. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola

    2014-05-02

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  14. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola; Hanafy, Sherif M.; Schuster, Gerard T.

    2014-01-01

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  15. Coupling effects of refractive index discontinuity, spot size and spot location on the deflection sensitivity of optical-lever based atomic force microscopy

    International Nuclear Information System (INIS)

    Liu Yu; Yang Jun

    2008-01-01

    Atomic force microscopy (AFM) plays an essential role in nanotechnology and nanoscience. The recent advances of AFM in bionanotechnology include phase imaging of living cells and detection of biomolecular interactions in liquid biological environments. Deflection sensitivity is a key factor in both imaging and force measurement, which is significantly affected by the coupling effects of the refractive index discontinuity between air, the glass window and the liquid medium, and the laser spot size and spot location. The effects of both the spot size and the spot location on the sensitivity are amplified by the refractive index discontinuity. The coupling effects may govern a transition of the deflection sensitivity from enhancement to degradation. It is also found that there is a critical value for the laser spot size, above which the deflection sensitivity is mainly determined by the refractive index of the liquid. Experimental results, in agreement with theoretical predication, elucidate the coupling effects

  16. Understanding refraction contrast using a comparison of absorption and refraction computed tomographic techniques

    Science.gov (United States)

    Wiebe, S.; Rhoades, G.; Wei, Z.; Rosenberg, A.; Belev, G.; Chapman, D.

    2013-05-01

    Refraction x-ray contrast is an imaging modality used primarily in a research setting at synchrotron facilities, which have a biomedical imaging research program. The most common method for exploiting refraction contrast is by using a technique called Diffraction Enhanced Imaging (DEI). The DEI apparatus allows the detection of refraction between two materials and produces a unique ''edge enhanced'' contrast appearance, very different from the traditional absorption x-ray imaging used in clinical radiology. In this paper we aim to explain the features of x-ray refraction contrast as a typical clinical radiologist would understand. Then a discussion regarding what needs to be considered in the interpretation of the refraction image takes place. Finally we present a discussion about the limitations of planar refraction imaging and the potential of DEI Computed Tomography. This is an original work that has not been submitted to any other source for publication. The authors have no commercial interests or conflicts of interest to disclose.

  17. Optical response in a laser-driven quantum pseudodot system

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, D. Gul [Physics Department, Graduate School of Natural and Applied Sciences, Dokuz Eylül University, 35390 Izmir (Turkey); Sakiroglu, S., E-mail: serpil.sakiroglu@deu.edu.tr [Physics Department, Faculty of Science, Dokuz Eylül University, 35390 Izmir (Turkey); Ungan, F.; Yesilgul, U. [Department of Optical Engineering, Faculty of Technology, Cumhuriyet University, 58140 Sivas (Turkey); Kasapoglu, E. [Physics Department, Faculty of Science, Cumhuriyet University, 58140 Sivas (Turkey); Sari, H. [Department of Primary Education, Faculty of Education, Cumhuriyet University, 58140 Sivas (Turkey); Sokmen, I. [Physics Department, Faculty of Science, Dokuz Eylül University, 35390 Izmir (Turkey)

    2017-03-15

    We investigate theoretically the intense laser-induced optical absorption coefficients and refractive index changes in a two-dimensional quantum pseudodot system under an uniform magnetic field. The effects of non-resonant, monochromatic intense laser field upon the system are treated within the framework of high-frequency Floquet approach in which the system is supposed to be governed by a laser-dressed potential. Linear and nonlinear absorption coefficients and relative changes in the refractive index are obtained by means of the compact-density matrix approach and iterative method. The results of numerical calculations for a typical GaAs quantum dot reveal that the optical response depends strongly on the magnitude of external magnetic field and characteristic parameters of the confinement potential. Moreover, we have demonstrated that the intense laser field modifies the confinement and thereby causes remarkable changes in the linear and nonlinear optical properties of the system.

  18. Optical response in a laser-driven quantum pseudodot system

    International Nuclear Information System (INIS)

    Kilic, D. Gul; Sakiroglu, S.; Ungan, F.; Yesilgul, U.; Kasapoglu, E.; Sari, H.; Sokmen, I.

    2017-01-01

    We investigate theoretically the intense laser-induced optical absorption coefficients and refractive index changes in a two-dimensional quantum pseudodot system under an uniform magnetic field. The effects of non-resonant, monochromatic intense laser field upon the system are treated within the framework of high-frequency Floquet approach in which the system is supposed to be governed by a laser-dressed potential. Linear and nonlinear absorption coefficients and relative changes in the refractive index are obtained by means of the compact-density matrix approach and iterative method. The results of numerical calculations for a typical GaAs quantum dot reveal that the optical response depends strongly on the magnitude of external magnetic field and characteristic parameters of the confinement potential. Moreover, we have demonstrated that the intense laser field modifies the confinement and thereby causes remarkable changes in the linear and nonlinear optical properties of the system.

  19. Control of waveguide properties by tuning femtosecond laser induced compositional changes

    International Nuclear Information System (INIS)

    Hoyo, Jesús; Fernandez, Toney Teddy del; Siegel, Jan; Solis, Javier; Vazquez, Rebeca Martinez; Osellame, Roberto; Sotillo, Belén; Fernández, Paloma

    2014-01-01

    Local compositional changes induced by high repetition rate fs-laser irradiation can be used to produce high performance optical waveguides in phosphate-based glasses. The waveguide refractive index contrast is determined by the local concentration of La, which can be changed by the action of the writing laser pulses. In this work, we have investigated the degree of control that can be exerted using this waveguide writing mechanism over the cross-section of the guiding region, and the local refractive index and compositional changes induced. These variables can be smoothly controlled via processing parameters using the slit shaping technique with moderate Numerical Aperture (NA 0.68) writing optics. The combined use of X-ray microanalysis and near field refractive index profilometry evidences a neat linear correlation between local La content and refractive index increase over a broad Δn interval (>3 × 10 −2 ). This result further confirms the feasibility of generating efficient, integrated optics elements via spatially selective modification of the glass composition.

  20. Measurements of electron density and temperature profiles in plasma produced by Nike KrF laser for laser plasma instability research

    Science.gov (United States)

    Oh, Jaechul; Weaver, J. L.; Karasik, M.; Chan, L. Y.

    2015-08-01

    A grid image refractometer (GIR) has been implemented at the Nike krypton fluoride laser facility of the Naval Research Laboratory. This instrument simultaneously measures propagation angles and transmissions of UV probe rays (λ = 263 nm, Δt = 10 ps) refracted through plasma. We report results of the first Nike-GIR measurement on a CH plasma produced by the Nike laser pulse (˜1 ns FWHM) with the intensity of 1.1 × 1015 W/cm2. The measured angles and transmissions were processed to construct spatial profiles of electron density (ne) and temperature (Te) in the underdense coronal region of the plasma. Using an inversion algorithm developed for the strongly refracted rays, the deployed GIR system probed electron densities up to 4 × 1021 cm-3 with the density scale length of 120 μm along the plasma symmetry axis. The resulting ne and Te profiles are verified to be self-consistent with the measured quantities of the refracted probe light.

  1. Multi-longitudinal-mode micro-laser model

    Science.gov (United States)

    Staliunas, Kestutis

    2017-10-01

    We derive a convenient model for broad aperture micro-lasers, such as microchip lasers, broad area semiconductor lasers, or VCSELs, taking into account several longitudinal mode families. We provide linear stability analysis, and show characteristic spatio-temporal dynamics in such multi-longitudinal mode laser models. Moreover, we derive the coupled mode model in the presence of intracavity refraction index modulation (intracavity photonic crystal). Contribution to the Topical Issue "Theory and Applications of the Lugiato-Lefever Equation", edited by Yanne K. Chembo, Damia Gomila, Mustapha Tlidi, Curtis R. Menyuk.

  2. Absolute Measurement of the Refractive Index of Water by a Mode-Locked Laser at 518 nm

    Directory of Open Access Journals (Sweden)

    Zhaopeng Meng

    2018-04-01

    Full Text Available In this paper, we demonstrate a method using a frequency comb, which can precisely measure the refractive index of water. We have developed a simple system, in which a Michelson interferometer is placed into a quartz-glass container with a low expansion coefficient, and for which compensation of the thermal expansion of the water container is not required. By scanning a mirror on a moving stage, a pair of cross-correlation patterns can be generated. We can obtain the length information via these cross-correlation patterns, with or without water in the container. The refractive index of water can be measured by the resulting lengths. Long-term experimental results show that our method can measure the refractive index of water with a high degree of accuracy—measurement uncertainty at 10−5 level has been achieved, compared with the values calculated by the empirical formula.

  3. Numerical analysis of laser ablation and damage in glass with multiple picosecond laser pulses.

    Science.gov (United States)

    Sun, Mingying; Eppelt, Urs; Russ, Simone; Hartmann, Claudia; Siebert, Christof; Zhu, Jianqiang; Schulz, Wolfgang

    2013-04-08

    This study presents a novel numerical model for laser ablation and laser damage in glass including beam propagation and nonlinear absorption of multiple incident ultrashort laser pulses. The laser ablation and damage in the glass cutting process with a picosecond pulsed laser was studied. The numerical results were in good agreement with our experimental observations, thereby revealing the damage mechanism induced by laser ablation. Beam propagation effects such as interference, diffraction and refraction, play a major role in the evolution of the crater structure and the damage region. There are three different damage regions, a thin layer and two different kinds of spikes. Moreover, the electronic damage mechanism was verified and distinguished from heat modification using the experimental results with different pulse spatial overlaps.

  4. Safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser.

    Science.gov (United States)

    Khoramnia, Ramin; Salgado, Josefina P; Wuellner, Christian; Donitzky, Christof; Lohmann, Chris P; Winkler von Mohrenfels, Christoph

    2012-09-01

    To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: -3.97±1.72 dioptres (D); mean cylinder: -0.84±0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6 months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed. We observed no adverse events that might have been associated with the use of a repetition rate of 1000 Hz. All eyes maintained or had improved BCDVA at 6 months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20/20 or better in 85% and 20/25 or better in 100% of the eyes. The spherical equivalent refraction was within ±0.50 D in 95% of the eyes at 6 months after surgery. The refraction stayed stable over time; 95% of the eyes changedLASIK with the prototype 1000-Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side-effects that might be associated with the use of such a high repetition rate. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  5. High-average-power laser medium based on silica glass

    Science.gov (United States)

    Fujimoto, Yasushi; Nakatsuka, Masahiro

    2000-01-01

    Silica glass is one of the most attractive materials for a high-average-power laser. We have developed a new laser material base don silica glass with zeolite method which is effective for uniform dispersion of rare earth ions in silica glass. High quality medium, which is bubbleless and quite low refractive index distortion, must be required for realization of laser action. As the main reason of bubbling is due to hydroxy species remained in the gelation same, we carefully choose colloidal silica particles, pH value of hydrochloric acid for hydrolysis of tetraethylorthosilicate on sol-gel process, and temperature and atmosphere control during sintering process, and then we get a bubble less transparent rare earth doped silica glass. The refractive index distortion of the sample also discussed.

  6. LASIK - Laser Eye Surgery

    Science.gov (United States)

    ... Refractive Surgery Procedures What Is Photorefractive Keratectomy (PRK)? LASIK — Laser Eye Surgery Leer en Español: LASIK—Cirugía ocular con láser ... loss of close-up focusing power. How the LASIK procedure works LASIK is performed while the patient ...

  7. Generation of J_0-Bessel-Gauss beam by a heterogeneous refractive index map

    KAUST Repository

    San Roman Alerigi, Damian

    2012-07-01

    In this paper, we present the theoretical studies of a refractive index map to implement a Gauss to a J0-Bessel-Gauss convertor. We theoretically demonstrate the viability of a device that could be fabricated on a Si/Si1-yOy/Si1-x-yGexCy platform or by photo-refractive media. The proposed device is 200 ?m in length and 25 ?m in width, and its refractive index varies in controllable steps across the light propagation and transversal directions. The computed conversion efficiency and loss are 90%, and -0.457 dB, respectively. The theoretical results, obtained from the beam conversion efficiency, self-regeneration, and propagation through an opaque obstruction, demonstrate that a two-dimensional (2D) graded index map of the refractive index can be used to transform a Gauss beam into a J0-Bessel-Gauss beam. To the best of our knowledge, this is the first demonstration of such beam transformation by means of a 2D index-mapping that is fully integrable in silicon photonics based planar lightwave circuits (PLCs). The concept device is significant for the eventual development of a new array of technologies, such as micro optical tweezers, optical traps, beam reshaping and nonlinear beam diode lasers. © 2012 Optical Society of America.

  8. Generation of J_0-Bessel-Gauss beam by a heterogeneous refractive index map

    KAUST Repository

    San Roman Alerigi, Damian; Alsunaidi, Mohammad; Ben Slimane, Ahmed; Ng, Tien Khee; Ooi, Boon S.; Zhang, Yaping

    2012-01-01

    In this paper, we present the theoretical studies of a refractive index map to implement a Gauss to a J0-Bessel-Gauss convertor. We theoretically demonstrate the viability of a device that could be fabricated on a Si/Si1-yOy/Si1-x-yGexCy platform or by photo-refractive media. The proposed device is 200 ?m in length and 25 ?m in width, and its refractive index varies in controllable steps across the light propagation and transversal directions. The computed conversion efficiency and loss are 90%, and -0.457 dB, respectively. The theoretical results, obtained from the beam conversion efficiency, self-regeneration, and propagation through an opaque obstruction, demonstrate that a two-dimensional (2D) graded index map of the refractive index can be used to transform a Gauss beam into a J0-Bessel-Gauss beam. To the best of our knowledge, this is the first demonstration of such beam transformation by means of a 2D index-mapping that is fully integrable in silicon photonics based planar lightwave circuits (PLCs). The concept device is significant for the eventual development of a new array of technologies, such as micro optical tweezers, optical traps, beam reshaping and nonlinear beam diode lasers. © 2012 Optical Society of America.

  9. Exploring vacuum birefringence based on a 100 PW laser and an x-ray free electron laser beam

    Science.gov (United States)

    Shen, Baifei; Bu, Zhigang; Xu, Jiancai; Xu, Tongjun; Ji, Liangliang; Li, Ruxin; Xu, Zhizhan

    2018-04-01

    Exploring vacuum birefringence with the station of extreme light at Shanghai Coherent Light Facility is considered. Laser pulses of intensity beyond 1023 W cm-2 are capable of polarizing the vacuum due to the ultra-strong electro-magnetic fields. The subtle difference of the vacuum refractive indexes along electric and magnetic fields leads to a birefringence effect for lights propagating through. The vacuum birefringence effect can now be captured by colliding a hard x-ray free electron laser (XFEL) beam with a high-power laser. The initial XFEL beam of pure linear polarization is predicated to gain a very small ellipticity after passing through the laser stimulated vacuum. Various interaction geometries are considered, showing that the estimated ellipticity lies between 1.8 × 10-10 and 10-9 for a 100 PW laser interacting with a 12.9 keV XFEL beam, approaching the threshold for todays’ polarity detection technique. The detailed experimental set-up is designed, including the polarimeter, the focusing compound refractive lens and the optical path. When taking into account the efficiencies of the x-ray instruments, it is found that about 10 polarization-flipped x-ray photons can be detected for a single shot for our design. Considering the background noise level, accumulating runs are necessary to obtain high confident measurement.

  10. Validity of spherical quantitative refractometry: application to laser-produced plasmas

    International Nuclear Information System (INIS)

    Benattar, R.; Popovics, C.

    1983-01-01

    We report an experimental laser technique of quantitative Schlieren imaging of spherical plasmas combined with streak camera recording. We show that quantitative refractometry applies for small values of refraction angles, i.e., when the law giving the refraction angle versus the impact parameter of rays passing through the plasma is a linearly decreasing function

  11. Recent developments in laser glasses

    International Nuclear Information System (INIS)

    Weber, M.J.

    1983-01-01

    The past decade has witnessed a proliferation of new glass-forming compositions including oxides, halides, oxyhalides, and chalcogenides. Many of these glasses are applicable to lasers and have greatly expanded the range of optical properties and spectroscopic parameters available to the laser designer. Our knowledge and understanding of many properties of interest for laser action - transparency, linear and nonlinear refractive indices, and damage threshold of the host glass and the absorption spectrum, radiative and nonradiative transition probabilities, fluorescence wavelength, stimulated emission cross section, and spectroscopic inhomogeneities of the lasing ion Nd 3 + - are reviewed

  12. Effect of annealing on refractive indices of radio-frequency magnetron sputtered waveguiding zinc oxide films on glass

    International Nuclear Information System (INIS)

    Mehan, Navina; Gupta, Vinay; Sreenivas, Kondepudy; Mansingh, Abhai

    2004-01-01

    The effects of annealing and gas composition on the refractive indices of zinc oxide films were studied in light of the structural properties. ZnO films (1 μm) were deposited by rf magnetron sputtering in different oxygen:argon mixtures on glass and annealed at 380 deg. C in air, at different times. Waveguide modes were excited in the films by prism coupling using a He-Ne laser. The estimated values of the extraordinary and ordinary refractive indices of the films, which were close to the corresponding bulk values (n e =2.006, n o =1.990), initially decreased with annealing time and later increased before becoming constant with further annealing. The variation in refractive indices was explained on the basis of contribution from both packing density p and lattice constant c of the films. The initial decrease in refractive indices was attributed to the observed lattice contraction, and the latter increase was explained in terms of the increase in packing density (p) of the films on annealing. A relation is proposed to estimate the refractive indices of films, which have the lattice constant c different from the bulk value

  13. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves

  14. Fluorescence imaging of lattice re-distribution on step-index direct laser written Nd:YAG waveguide lasers

    Energy Technology Data Exchange (ETDEWEB)

    Martínez de Mendívil, Jon; Pérez Delgado, Alberto; Lifante, Ginés; Jaque, Daniel [Departamento de Física de Materiales, Facultad de Ciencias, Universidad Autónoma de Madrid, Madrid 28049 (Spain); Ródenas, Airán [Departament de Química Física i Inorgànica, Universitat Rovira i Virgili, Tarragona 43007 (Spain); Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Benayas, Antonio, E-mail: antonio.benayas@emt.inrs.ca [Departamento de Física de Materiales, Facultad de Ciencias, Universidad Autónoma de Madrid, Madrid 28049 (Spain); Institut National de la Recherche Scientifique, Centre – Énergie Matériaux et Télécommunications, 1650, Boul. Lionel Boulet Varennes, Quebec J3X 1S2 (Canada); Aguiló, Magdalena; Diaz, Francesc [Departament de Química Física i Inorgànica, Universitat Rovira i Virgili, Tarragona 43007 (Spain); Kar, Ajoy K. [Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom)

    2015-01-14

    The laser performance and crystalline micro-structural properties of near-infrared step-index channel waveguides fabricated inside Neodymium doped YAG laser ceramics by means of three-dimensional sub-picosecond pulse laser direct writing are reported. Fluorescence micro-mapping of the waveguide cross-sections reveals that an essential crystal lattice re-distribution has been induced after short pulse irradiation. Such lattice re-distribution is evidenced at the waveguide core corresponding to the laser written refractive index increased volume. The waveguides core surroundings also present diverse changes including slight lattice disorder and bi-axial strain fields. The step-index waveguide laser performance is compared with previous laser fabricated waveguides with a stress-optic guiding mechanism in absence of laser induced lattice re-distribution.

  15. Collagen crosslinking for ectasia following PRK performed in excimer laser-assisted keratoplasty for keratoconus.

    Science.gov (United States)

    Spadea, Leopoldo

    2012-01-01

    To report the results of corneal collagen crosslinking (CXL) in a patient with corneal ectasia developed after excimer laser-assisted lamellar keratoplasty for keratoconus and a secondary photorefractive keratectomy (PRK) for residual refractive error. A 33-year-old woman, who had originally been treated for keratoconus in the right eye by excimer laser-assisted lamellar keratoplasty, subsequently had her residual ametropia treated by topographically guided, transepithelial excimer laser PRK. Five years after PRK, the patient developed corneal ectasia showing concomitant visual changes of best spectacle-corrected visual acuity (BSCVA) reduced to 20/33 with a refraction of -6.00 +6.00 × 30. The minimum corneal thickness at the ectasia apex was 406 µm. A treatment of riboflavin-UVA-induced corneal CXL was performed on the right eye. Two years after the CXL treatment, the right eye improved to 20/20 BSCVA with a refraction of plano +1.00 × 50 while exhibiting a clear lamellar graft. Corneal CXL provided safe and effective management of ectasia developed after excimer laser-assisted lamellar keratoplasty and PRK.

  16. Structured-Light Based 3d Laser Scanning of Semi-Submerged Structures

    Science.gov (United States)

    van der Lucht, J.; Bleier, M.; Leutert, F.; Schilling, K.; Nüchter, A.

    2018-05-01

    In this work we look at 3D acquisition of semi-submerged structures with a triangulation based underwater laser scanning system. The motivation is that we want to simultaneously capture data above and below water to create a consistent model without any gaps. The employed structured light scanner consist of a machine vision camera and a green line laser. In order to reconstruct precise surface models of the object it is necessary to model and correct for the refraction of the laser line and camera rays at the water-air boundary. We derive a geometric model for the refraction at the air-water interface and propose a method for correcting the scans. Furthermore, we show how the water surface is directly estimated from sensor data. The approach is verified using scans captured with an industrial manipulator to achieve reproducible scanner trajectories with different incident angles. We show that the proposed method is effective for refractive correction and that it can be applied directly to the raw sensor data without requiring any external markers or targets.

  17. STRUCTURED-LIGHT BASED 3D LASER SCANNING OF SEMI-SUBMERGED STRUCTURES

    Directory of Open Access Journals (Sweden)

    J. van der Lucht

    2018-05-01

    Full Text Available In this work we look at 3D acquisition of semi-submerged structures with a triangulation based underwater laser scanning system. The motivation is that we want to simultaneously capture data above and below water to create a consistent model without any gaps. The employed structured light scanner consist of a machine vision camera and a green line laser. In order to reconstruct precise surface models of the object it is necessary to model and correct for the refraction of the laser line and camera rays at the water-air boundary. We derive a geometric model for the refraction at the air-water interface and propose a method for correcting the scans. Furthermore, we show how the water surface is directly estimated from sensor data. The approach is verified using scans captured with an industrial manipulator to achieve reproducible scanner trajectories with different incident angles. We show that the proposed method is effective for refractive correction and that it can be applied directly to the raw sensor data without requiring any external markers or targets.

  18. Resonant infrared laser deposition of polymer-nanocomposite materials for optoelectronic applications

    Science.gov (United States)

    Park, Hee K.; Schriver, Kenneth E.; Haglund, Richard F.

    2011-11-01

    Polymers find a number of potentially useful applications in optoelectronic devices. These include both active layers, such as light-emitting polymers and hole-transport layers, and passive layers, such as polymer barrier coatings and light-management films. This paper reports the experimental results for polymer films deposited by resonant infrared matrix-assisted pulsed laser evaporation (RIR-MAPLE) and resonant infrared pulsed laser deposition (RIR-PLD) for commercial optoelectronic device applications. In particular, light-management films, such as anti-reflection coatings, require refractive-index engineering of a material. However, refractive indices of polymers fall within a relatively narrow range, leading to major efforts to develop both low- and high-refractive-index polymers. Polymer nanocomposites can expand the range of refractive indices by incorporating low- or high-refractive-index nanoscale materials. RIR-MAPLE is an excellent technique for depositing polymer-nanocomposite films in multilayer structures, which are essential to light-management coatings. In this paper, we report our efforts to engineer the refractive index of a barrier polymer by combining RIR-MAPLE of nanomaterials (for example, high refractive-index TiO2 nanoparticles) and RIR-PLD of host polymer. In addition, we report on the properties of organic and polymer films deposited by RIR-MAPLE and/or RIR-PLD, such as Alq3 [tris(8-hydroxyquinoline) aluminum] and PEDOT:PSS [poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate)]. Finally, the challenges and potential for commercializing RIR-MAPLE/PLD, such as industrial scale-up issues, are discussed.

  19. In situ visualizing the evolution of the light-induced refractive index change of Mn:KLTN crystal with digital holographic interferometry

    Directory of Open Access Journals (Sweden)

    Jinxin Han

    2015-04-01

    Full Text Available The light-induced refractive index change in Mn:KLTN crystal, illuminated by focused light sheet, is visualized in situ and quantified by digital holographic interferometry. By numerically retrieving a series of sequential phase maps from recording digital holograms, the spatial distribution of the induced refractive index change can be visualized and estimated readily. This technique enables the observation of the temporal evolution of the refractive index change under different recording situations such as writing laser power, applied voltage, and temperature, and the photoconductivity of Mn:KLTN crystal can be calculated as well, the experimental results are in good agreement with the theory. The research results suggest that the presented method is successful and feasible.

  20. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  1. Preliminary study of the correlation between refractive error and corneal refractive power, corneal asphericity in myopic eye

    Directory of Open Access Journals (Sweden)

    Qi-Chao Han

    2014-05-01

    Full Text Available AIM: To investigate the correlation between myopic refractive error and relative factors, including the corneal refractive power, posterior refractive power, axial length, corneal asphericity coefficient Q value, central cornea thickness(CCTand intraocular pressure(IOP. METHODS:According to the degree of myopia measured by subjective refraction, 138 myopia patients were divided into three subgroups: mild group(-1.00D--3.00D, moderate group(-3.25D--6.00D, high group(>6.00D. The Pentacam anterior segment tomographer(Germany, Oculus Companywas used to measure the corneal refractive power, posterior refractive power, and corneal asphericity in the right eye. IOP, CCT and axial length were measured by a non-contact tonometer and A-scan ultrasonic, respectively. The data was analyzed with a Pearson correlation analysis and one-way ANOVA. RESULTS: The myopic refractive error was negatively correlated with the axial length(r=-0.682, Pr=0.009, P=0.925. The axial length was negatively correlated with corneal refractive power(r=-0.554, Pr=0.674, Pr=-0.375, P=0.01. There was no significantly correlation between the myopic refractive error and CCT, IOP(r=-0.138, P=0.141; r=-0.121, P=0.157. CONCLUSION:The corneal refractive power plays the role of emmetropization during the development of myopia. There is clinic significance for the correlation between Q value and refractive error, IOP to guide the corneal refractive surgery.

  2. Preparation and Characterization of Bragg Fibers for Delivery of Laser Radiation at 1064 nm

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2013-04-01

    Full Text Available Bragg fibers offer new performance for transmission of high laser energies over long distances. In this paper theoretical modeling, preparation and characterization of Bragg fibers for delivery laser radiation at 1064 nm are presented. Investigated Bragg fibers consist of the fiber core with a refractive index equal to that of silica which is surrounded by three pairs of circular layers. Each pair is composed of one layer with a high and one layer with a low refractive index and characterized by a refractive-index difference around 0.03. Propagation constants and radiation losses of the fundamental mode in such a structure were calculated on the basis of waveguide optics. Preforms of the Bragg fibers were prepared by the MCVD method using germanium dioxide, phosphorous pentoxide and fluorine as silica dopants. The fibers with a diameter of 170 m were drawn from the preforms. Refractive-index profiles, angular distributions of the output power and optical losses of the prepared fibers were measured. Results of testing the fibers for delivery radiation of a pulse Nd:YAG laser at 1064 nm are also shown.

  3. Nonlinear interaction of charged particles with strong laser pulses in a gaseous media

    Directory of Open Access Journals (Sweden)

    H. K. Avetissian

    2007-07-01

    Full Text Available The charged particles nonlinear dynamics in the field of a strong electromagnetic wave pulse of finite duration and certain form of the envelope, in the refractive medium with a constant and variable refraction indexes, is investigated by means of numerical integration of the classical relativistic equations of motion. The particle energy dependence on the pulse intensity manifests the nonlinear threshold phenomenon of a particle reflection and capture by actual laser pulses in dielectric-gaseous media that takes place for a plane electromagnetic wave in the induced Cherenkov process. Laser acceleration of the particles in the result of the reflection from the pulse envelope and in the capture regime with the variable refraction index along the pulse propagation direction is investigated.

  4. A model for self-defocusing in laser drilling of polymeric materials

    International Nuclear Information System (INIS)

    Zhang Chong; Quick, Nathaniel R.; Kar, Aravinda

    2008-01-01

    A numerical thermal model is presented for laser microvias drilling in multilayer electronic substrates with Nd:YAG (YAG denotes yttrium aluminum garnet) and CO 2 lasers. Such substrates have different optical properties such as the refractive index and absorption coefficient at these two laser wavelengths, resulting in different drilling mechanisms. Since the skin depth of the polymer is large for both the lasers, volumetric heating is considered in the model. As soon as a small cavity is formed during the drilling process, the concave curvature of the drilling front acts as a concave lens that diverges the incident laser beam. This self-defocusing effect can greatly reduce the drilling speed as predicted by the model. This effect makes the refractive index of the substrate at different wavelengths an important parameter for laser drilling. The model was used to calculate the laser ablation thresholds which were found to be 8 and 56 J/cm 2 for the CO 2 and Nd:YAG lasers respectively. Due to the expulsion of materials because of high internal pressures in the case of Nd:YAG laser microvia drilling, the ablation threshold may be far below the calculated value. A particular laser beam shape, such as pitch fork, was found to drill better holes than the Gaussian beam

  5. Excimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.

    Science.gov (United States)

    Lukenda, Adrian; Martinović, Zeljka Karaman; Kalauz, Miro

    2012-06-01

    The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many years lagged behind that of myopia. Most of today's scanning laser systems, used in the LASIK and PRK procedures, can safely and effectively perform low, moderate and high hyperopic and hyperopic astigmatic corrections. The introduction of these laser platforms has also significantly improved the long term refractive stability of hyperopic treatments. In the future, further improvements in femtosecond and nanosecond technology, eye-tracker systems, and the development of new customized algorithms, such as the ray-tracing method, could additionally increase the upper limit for the safe and predictable corneal ablative laser correction ofhyperopia, hyperopic and mixed astigmatism.

  6. Deviations of Lambert-Beer???s law affect corneal refractive parameters after refractive surgery

    OpenAIRE

    Jim??nez Cuesta, Jos?? Ram??n; Rodr??guez-Mar??n, Francisco; Gonz??lez Anera, Rosario; Jim??nez del Barco Jaldo, Luis Miguel

    2006-01-01

    We calculate whether deviations of Lambert-Beer???s law, which regulates depth ablation during corneal ablation, significantly influence corneal refractive parameters after refractive surgery and whether they influence visual performance. For this, we compute a point-to-point correction on the cornea while assuming a non-linear (including a quadratic term) fit for depth ablation. Post-surgical equations for refractive parameters using a non-linear fit show significant differences with respect...

  7. Control of waveguide properties by tuning femtosecond laser induced compositional changes

    Energy Technology Data Exchange (ETDEWEB)

    Hoyo, Jesús; Fernandez, Toney Teddy del; Siegel, Jan; Solis, Javier, E-mail: j.solis@io.cfmac.csic.es [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, 28006 Madrid (Spain); Vazquez, Rebeca Martinez; Osellame, Roberto [Instituto di Fotonica e Nanotecnologie, CNR, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Sotillo, Belén; Fernández, Paloma [Depto. de Física de Materiales, Facultad de Físicas, Univ. Complutense, 28040 Madrid (Spain)

    2014-09-29

    Local compositional changes induced by high repetition rate fs-laser irradiation can be used to produce high performance optical waveguides in phosphate-based glasses. The waveguide refractive index contrast is determined by the local concentration of La, which can be changed by the action of the writing laser pulses. In this work, we have investigated the degree of control that can be exerted using this waveguide writing mechanism over the cross-section of the guiding region, and the local refractive index and compositional changes induced. These variables can be smoothly controlled via processing parameters using the slit shaping technique with moderate Numerical Aperture (NA 0.68) writing optics. The combined use of X-ray microanalysis and near field refractive index profilometry evidences a neat linear correlation between local La content and refractive index increase over a broad Δn interval (>3 × 10{sup −2}). This result further confirms the feasibility of generating efficient, integrated optics elements via spatially selective modification of the glass composition.

  8. Waveguide formation by laser backwriting ablation of metals unto glass substrates

    International Nuclear Information System (INIS)

    Rangel-Rojo, R.; Castelo, A.; Flores-Arias, M. T.; Gomez-Reino, C.; Lopez-Gascon, C.; Fuente, G. F. de la

    2008-01-01

    In this work we present experimental results for the generation of channel waveguides by a laser backwriting technique using a nanosecond pulsed Nd:YAG laser working at 1064 nm. We present a characterization of the resulting refractive index profile, using the refracted near-field technique, together with a spatially resolved chemical analysis based on energy dispersive x-ray analysis(EDX). The EDX results confirm that metal ions are embedded in a region close to the substrate interface, up to about a 5 μm depth. We also present a discussion of the physical mechanisms that produce the profiles measured

  9. Waveguide formation by laser backwriting ablation of metals unto glass substrates

    Energy Technology Data Exchange (ETDEWEB)

    Rangel-Rojo, R [Departamento de Optica, Centro de Investigacion Cientifica y de Educacion Superior de Ensenada, Apartado Postal 2732, Ensenada BC 22860 (Mexico); Castelo, A; Flores-Arias, M T; Gomez-Reino, C [GRIN Optics Group. Applied Physics Department, Escola Universitaria de Optica e Optometria, Universidad de Santiago de Compostela, Campus Sur s/n, E15782 Santiago de Compostela, Espana (Spain); Lopez-Gascon, C; Fuente, G F. de la [Instituto de Ciencia de Materiales de Aragon (U. Zaragoza-CSIC), Ma. de Luna 3, E50018 Zaragoza (Spain)

    2008-04-15

    In this work we present experimental results for the generation of channel waveguides by a laser backwriting technique using a nanosecond pulsed Nd:YAG laser working at 1064 nm. We present a characterization of the resulting refractive index profile, using the refracted near-field technique, together with a spatially resolved chemical analysis based on energy dispersive x-ray analysis(EDX). The EDX results confirm that metal ions are embedded in a region close to the substrate interface, up to about a 5 {mu}m depth. We also present a discussion of the physical mechanisms that produce the profiles measured.

  10. Spectral dynamics of square pulses in passively mode-locked fiber lasers

    Science.gov (United States)

    Semaan, Georges; Komarov, Andrey; Niang, Alioune; Salhi, Mohamed; Sanchez, François

    2018-02-01

    We investigate experimentally and numerically the spectral dynamics of square pulses generated in passively mode-locked fiber lasers under the dissipative soliton resonance. The features of the transition from the single-peak spectral profile to the doublet spectrum with increasing pump power are studied. The used master equation takes into account the gain saturation, the quadratic frequency dispersion of the gain and the refractive index, and the cubic-quintic nonlinearity of the losses and refractive index. Experimental data are obtained for an Er:Yb-doped fiber ring laser. The theoretical and experimental results are in good agreement with each other.

  11. Refractive index dispersion measurement using carrier-envelope phasemeters

    International Nuclear Information System (INIS)

    Hansinger, Peter; Töpfer, Philipp; Adolph, Daniel; Hoff, Dominik; Rathje, Tim; Sayler, A Max; Paulus, Gerhard G; Dimitrov, Nikolay; Dreischuh, Alexander

    2017-01-01

    We introduce a novel method for direct and accurate measurement of refractive index dispersion based on carrier-envelope phase detection of few-cycle laser pulses, exploiting the difference between phase and group velocity in a dispersive medium. In a layout similar to an interferometer, two carrier-envelope phasemeters are capable of measuring the dispersion of a transparent or reflective sample, where one phasemeter serves as the reference and the other records the influence of the sample. Here we report on proof-of-principle measurements that already reach relative uncertainties of a few 10 −4 . Further development is expected to allow for unprecedented precision. (paper)

  12. Characterization of Chromatic Dispersion and Refractive Index of Polymer Optical Fibers

    Directory of Open Access Journals (Sweden)

    Igor Ayesta

    2017-12-01

    Full Text Available The chromatic dispersion and the refractive index of poly(methyl methacrylate polymer optical fibers (POFs have been characterized in this work by using a tunable femtosecond laser and a Streak Camera. The characterization technique is based on the measurement of the time delays of light pulses propagating along POFs at different wavelengths. Polymer fibers of three different lengths made by two manufacturers have been employed for that purpose, and discrepancies lower than 3% have been obtained in all cases.

  13. Low-loss 3D-laser-written mid-infrared LiNbO3 depressed-index cladding waveguides for both TE and TM polarizations.

    Science.gov (United States)

    Nguyen, Huu-Dat; Ródenas, Airán; Vázquez de Aldana, Javier R; Martín, Guillermo; Martínez, Javier; Aguiló, Magdalena; Pujol, Maria Cinta; Díaz, Francesc

    2017-02-20

    We report mid-infrared LiNbO3 depressed-index microstructured cladding waveguides fabricated by three-dimensional laser writing showing low propagation losses (~1.5 dB/cm) at 3.68 µm wavelength for both the transverse electric and magnetic polarized modes, a feature previously unachieved due to the strong anisotropic properties of this type of laser microstructured waveguides and which is of fundamental importance for many photonic applications. Using a heuristic modeling-testing iteration design approach which takes into account cladding induced stress-optic index changes, the fabricated cladding microstructure provides low-loss single mode operation for the mid-IR for both orthogonal polarizations. The dependence of the localized refractive index changes within the cladding microstructure with post-fabrication thermal annealing processes was also investigated, revealing its complex dependence of the laser induced refractive index changes on laser fabrication conditions and thermal post-processing steps. The waveguide modes properties and their dependence on thermal post-processing were numerically modeled and fitted to the experimental values by systematically varying three fundamental parameters of this type of waveguides: depressed refractive index values at sub-micron laser-written tracks, track size changes, and piezo-optic induced refractive index changes.

  14. FEATURES OF MULTIPLEXED HOLOGRAMS RECORDING IN PHOTO-THERMO-REFRACTIVE GLASS

    Directory of Open Access Journals (Sweden)

    S. A. Ivanov

    2016-05-01

    Full Text Available We have carried out calculations of recording conditions for multiplexed holograms in photo-thermo-refractive (PTR glass. The proposed calculation sets the link between such parameters as: the angle between recording beams and the angle of sample rotation, operating wavelength, the angle of incidence on the element, output angle. To study recording features of multiplexed holograms on PTR glass several elements was made. Six holograms in each element were recorded with various exposures. All samples were heat-treated at one temperature around glass transition temperature. It has been demonstrated that at the recording of several gratings with a total exposure exceeding an optimal value for a given material, the total value of the refractive index modulation amplitude (n1 reaches the maximum attainable magnitude that is equivalent to a value of a single hologram with optimal exposure. It has been found that refractive index dynamic range of the material distributes between the gratings in accordance with the ratio between exposure times if holograms exposures have significant differences. In the present paper six-channel multiplexer was recorded for a wavelength equal to 632.8 nm (He-Ne laser. The diffraction angles correspond to calculations mentioned above. The n1 value in each grating is equal to the value of the highest attainable value of the value of n1 divided by the total number of multiplexed holograms.

  15. Contribution of the Refractive Index Fluctuations to the Length Noise in Displacement Interferometry

    Czech Academy of Sciences Publication Activity Database

    Holá, Miroslava; Hrabina, Jan; Šarbort, Martin; Oulehla, Jindřich; Číp, Ondřej; Lazar, Josef

    2015-01-01

    Roč. 15, č. 5 (2015), s. 263-267 ISSN 1335-8871 R&D Projects: GA ČR GB14-36681G; GA TA ČR TA02010711; GA TA ČR TE01020233; GA MŠk(CZ) LO1212; GA MŠk EE2.3.30.0054 Institutional support: RVO:68081731 Keywords : nanometrology * interferometry * refractive index of air Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.969, year: 2015

  16. Questionnaires for Measuring Refractive Surgery Outcomes.

    Science.gov (United States)

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  17. Indirect absorption spectroscopy using quantum cascade lasers: mid-infrared refractometry and photothermal spectroscopy.

    Science.gov (United States)

    Pfeifer, Marcel; Ruf, Alexander; Fischer, Peer

    2013-11-04

    We record vibrational spectra with two indirect schemes that depend on the real part of the index of refraction: mid-infrared refractometry and photothermal spectroscopy. In the former, a quantum cascade laser (QCL) spot is imaged to determine the angles of total internal reflection, which yields the absorption line via a beam profile analysis. In the photothermal measurements, a tunable QCL excites vibrational resonances of a molecular monolayer, which heats the surrounding medium and changes its refractive index. This is observed with a probe laser in the visible. Sub-monolayer sensitivities are demonstrated.

  18. CO2 laser treatment of As-S chalcogenide thin films

    International Nuclear Information System (INIS)

    Andriesch, A.M.; Bertolotti, M.; Ferrari, A.; Popesku, A.A.

    1990-01-01

    The changes of the refractive index of As 2 S 3 and As 2 S 5 films deposited on glass substrates upon CO 2 laser irradiation have been studied. The possibility of writing with the CO 2 laser a waveguiding channel in As 2 S 3 is demonstrated

  19. Refraction and visual acuity in a national Danish cohort of 4-year-old children of extremely preterm delivery

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Bangsgaard, Regitze; Slidsborg, Carina

    2015-01-01

    PURPOSE: A recent threefold increase in laser treatment for advanced retinopathy of prematurity (ROP) triggered a nationwide preschool ophthalmic and developmental status among extremely preterm survivors. Here, we discuss refraction and visual acuity. METHODS: Survivors (n = 178) from a national...... was 0.1 in FT and 0.2 in PT, in Snellen equivalents 0.8 and 0.63. Snellen acuity ≤0.5 occurred across the ROP subgroups, but mainly in those with at least ROP stage 3. Two children had low vision. CONCLUSIONS: The overall fair outcome for refraction and function is in accordance with other recent...

  20. Laser Eye Surgery: MedlinePlus Health Topic

    Science.gov (United States)

    ... corneal surgery - discharge (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Laser Eye Surgery ... surgery - what to ask your doctor Related Health Topics Refractive Errors National Institutes of Health The primary ...

  1. Effects of resonator input power on Kerr lens mode-locked lasers

    Indian Academy of Sciences (India)

    lasers. S KAZEMPOUR, A KESHAVARZ∗ and G HONARASA. Department of Physics, Faculty of Sciences, Shiraz University of Technology, Shiraz, Iran ... Keywords. Femtosecond pulses; Kerr lens sensitivity; Kerr lens mode-locked laser. ... The optical lengths of Kerr medium with thickness d and refractive index n under.

  2. Influence of refraction index strength on the light propagation in dielectrics material with periodic refraction index

    International Nuclear Information System (INIS)

    Hidayat, Arif; Latifah, Eny; Kurniati, Diana; Wisodo, Hari

    2016-01-01

    This study investigated the influence of refraction index strength on the light propagation in refraction index-varied dielectric material. This dielectric material served as photonic lattice. The behavior of light propagation influenced by variation of refraction index in photonic lattice was investigated. Modes of the guiding light were determined numerically using squared-operator iteration method. It was found that the greater the strength of refraction index, the smaller the guiding modes.

  3. Periodical rocking long period gratings in PANDA fibers for high temperature and refractive index sensing

    Science.gov (United States)

    Jin, Wa; Bi, Wei-hong; Fu, Xing-hu; Fu, Guang-wei

    2017-09-01

    We report periodical rocking long period gratings (PR-LPGs) in PANDA fibers fabricated with CO2 laser. The PR-LPGs achieve very high coupling efficiency of 19 dB with 12 periods and a 3.5° twist angle in just one scanning cycle, which is much more effective than the conventional CO2 laser fabrication technique. This type of LPGs exhibits polarization-selective resonance dips which demonstrate different sensitivities to environmental parameters. The high temperature and external refractive index sensitivities are measured simultaneously, so it can be used as a wavelength-selective polarization filter and sensor.

  4. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  5. Pulse laser ablation at water-air interface

    Science.gov (United States)

    Utsunomiya, Yuji; Kajiwara, Takashi; Nishiyama, Takashi; Nagayama, Kunihito; Kubota, Shiro

    2010-06-01

    We studied a new pulse laser ablation phenomenon on a liquid surface layer, which is caused by the difference between the refractive indices of the two materials involved. The present study was motivated by our previous study, which showed that laser ablation can occur at the interface between a transparent material and a gas or liquid medium when the laser pulse is focused through the transparent material. In this case, the ablation threshold fluence is reduced remarkably. In the present study, experiments were conducted in water and air in order to confirm this phenomenon for a combination of two fluid media with different refractive indices. This phenomenon was observed in detail by pulse laser shadowgraphy. A high-resolution film was used to record the phenomenon with a Nd:YAG pulse laser with 10-ns duration as a light source. The laser ablation phenomenon on the liquid surface layer caused by a focused Nd:YAG laser pulse with 1064-nm wavelength was found to be followed by the splashing of the liquid surface, inducing a liquid jet with many ligaments. The liquid jet extension velocity was around 1000 m/s in a typical case. The liquid jet decelerated drastically due to rapid atomization at the tips of the ligaments. The liquid jet phenomenon was found to depend on the pulse laser parameters such as the laser fluence on the liquid surface, laser energy, and laser beam pattern. The threshold laser fluence for the generation of a liquid jet was 20 J/cm2. By increasing the incident laser energy with a fixed laser fluence, the laser focused area increased, which eventually led to an increase in the size of the plasma column. The larger the laser energy, the larger the jet size and the longer the temporal behavior. The laser beam pattern was found to have significant effects on the liquid jet’s velocity, shape, and history.

  6. Optical skin biopsies by clinical CARS and multiphoton fluorescence/SHG tomography

    International Nuclear Information System (INIS)

    König, K; Breunig, H G; Bückle, R; Kellner-Höfer, M; Weinigel, M; Büttner, E; Sterry, W; Lademann, J

    2011-01-01

    The ultimate challenge for early diagnostics is label-free high-resolution intratissue imaging without taking physical biopsies. A novel hybrid femtosecond laser tomograph provides in vivo optical biopsies of human skin based on non-linear excitation of autofluorescence and the detection of lipids and water by CARS. Applications include skin cancer detection, biosafety tests of intradermal nanoparticles, and the testing of anti-aging products

  7. Comparison of the ratio of keratometric change to refractive change induced by myopic ablation.

    Science.gov (United States)

    Moshirfar, Majid; Christiansen, Steven M; Kim, Gene

    2012-10-01

    To compare the ratio of keratometric change (ΔK) to refractive change (ΔSE) induced by refractive laser ablation. The charts of 3337 eyes that underwent LASIK or photorefractive keratectomy (PRK) from 2002 to 2011 were retrospectively reviewed, and the ratio ΔK/ΔSE measured at 3 months postoperatively was compared between eyes with low ΔSE (0.00 to 2.99 diopters [D]), moderate ΔSE (3.00 to 5.99 D), and high ΔSE (6.00 to 8.99 D). Eyes were further stratified by LASIK vs PRK; custom vs conventional treatments; microkeratome vs IntraLase (Abbott Medical Optics Inc) femtosecond laser-created flaps; and flat (38.00 to 41.99 D) vs moderate (42.00 to 45.99 D) vs steep (46.00 to 49.99 D) preoperative keratometry, and the ratio ΔK/ΔSE was similarly compared. Significant differences were found in the ratio ΔK/ΔSE among eyes with low ΔSE (1.00±0.50 D), moderate ΔSE (0.83±0.19 D), and steep ΔSE (0.80±0.15 D) (PLASIK vs PRK, custom vs conventional treatments, and microkeratome vs IntraLase flaps. Significant differences in the ratio ΔK/ΔSE were also found in eyes with low, moderate, and high ΔSE regardless of preoperative keratometry. The ratio ΔK/ΔSE compared with ΔSE follows a nonlinear pattern and tended to be higher and more variable at lower amounts of correction. The change in simulated keratometry required to achieve 1.00 D of myopic refractive correction decreased as the amount of refractive change increased, was more variable with lower amounts of correction, and followed a nonlinear relationship. Many variables, such as LASIK vs PRK, custom vs conventional, and microkeratome vs IntraLase flaps, affected the ratio of ΔK/ΔSE for moderate and high myopic corrections. Copyright 2012, SLACK Incorporated.

  8. Laser Refractography

    CERN Document Server

    Rinkevichyus, B.S; Raskovskaya, I.L

    2010-01-01

    This book describes the basic principles of laser refractography, a flexible new diagnostic tool for measuring optically inhomogeneous media and flows. Laser refractography is based on digital imaging and computer processing of structured laser beam refraction (SLR) in inhomogeneous transparent media. Laser refractograms provide both qualitative and quantitative measurements and can be used for the study of fast and transient processes. In this book, the theoretical basis of refractography is explored in some detail, and experimental setups are described for measurement of transparent media using either 2D (passed radiation) or 3D (scattered radiation) refractograms. Specific examples and applications are discussed, including visualization of the boundary layer near a hot or cold metallic ball in water, and observation of edge effects and microlayers in liquids and gases. As the first book to describe this new and exciting technique, this monograph has broad cross-disciplinary appeal and will be of interest t...

  9. Measurement of the Specific Refractivities of CF4 and C2F6

    Science.gov (United States)

    Burner, A. W.; Goad, W. K.

    1977-01-01

    In order to relate the measured fringe shift of an interferometer to density, the relation between density rho and refractive index n must be known. For gases where the refractive index is close to unity, this relation between density and refractive index is very closely approximated by (n - 1) = K rho where K is the specific refractivity, or the Gladstone-Dale constant. The specific refractivity, which is weakly dependent on wavelength and temperature, is readily available for a number of common test gases such as N2 and air. For more unique test gases such as CF4 and C2F6 for which refractive index data at optical wavelengths is not readily available, the constants can be estimated from the atomic refractivities of carbon and fluorine. In order to verify this estimation, a two-beam interferometer was used to experimentally determine the specific refractivities of CF4 and C2F6. This data was required for holographic interferometric measurements made at the Langley Hypersonic CF4 Tunnel. A Twyman-Green interferometer with a He-Ne laser light source of vacuum wavelength lambda equal to 633 nm was used to measure the constants. One beam of the two-beam interferometer passed through an optical cell of known inside length l which could be evacuated and slowly filled with the test gas to a density of 7.2 kg/cu m for CF4 or 5.7 kg/cu m for C2F6. If the refractive index (and hence density) is constant along the optical path through the cell, the fringe shift M and density change Delta rho are related M = 2Kl Delta rho/lambda for the double pass interferometer. Thus K can be determined by measuring the fringe shift as the density is changed. The output of a photodiode used to detect the fringe shift was recorded on a strip chart recorder. The rate of pressure increase of the test gas in the cell was controlled such that the fringes shifted at a rate of 0.5 to 1 fringe per sec. The pressure in the test cell was measured with a high accuracy quartz crystal pressure

  10. Predicting fiber refractive index from a measured preform index profile

    Science.gov (United States)

    Kiiveri, P.; Koponen, J.; Harra, J.; Novotny, S.; Husu, H.; Ihalainen, H.; Kokki, T.; Aallos, V.; Kimmelma, O.; Paul, J.

    2018-02-01

    When producing fiber lasers and amplifiers, silica glass compositions consisting of three to six different materials are needed. Due to the varying needs of different applications, substantial number of different glass compositions are used in the active fiber structures. Often it is not possible to find material parameters for theoretical models to estimate thermal and mechanical properties of those glass compositions. This makes it challenging to predict accurately fiber core refractive index values, even if the preform index profile is measured. Usually the desired fiber refractive index value is achieved experimentally, which is expensive. To overcome this problem, we analyzed statistically the changes between the measured preform and fiber index values. We searched for correlations that would help to predict the Δn-value change from preform to fiber in a situation where we don't know the values of the glass material parameters that define the change. Our index change models were built using the data collected from preforms and fibers made by the Direct Nanoparticle Deposition (DND) technology.

  11. Anisotropic power spectrum of refractive-index fluctuation in hypersonic turbulence.

    Science.gov (United States)

    Li, Jiangting; Yang, Shaofei; Guo, Lixin; Cheng, Mingjian

    2016-11-10

    An anisotropic power spectrum of the refractive-index fluctuation in hypersonic turbulence was obtained by processing the experimental image of the hypersonic plasma sheath and transforming the generalized anisotropic von Kármán spectrum. The power spectrum suggested here can provide as good a fit to measured spectrum data for hypersonic turbulence as that recorded from the nano-planar laser scattering image. Based on the newfound anisotropic hypersonic turbulence power spectrum, Rytov approximation was employed to establish the wave structure function and the spatial coherence radius model of electromagnetic beam propagation in hypersonic turbulence. Enhancing the anisotropy characteristics of the hypersonic turbulence led to a significant improvement in the propagation performance of electromagnetic beams in hypersonic plasma sheath. The influence of hypersonic turbulence on electromagnetic beams increases with the increase of variance of the refractive-index fluctuation and the decrease of turbulence outer scale and anisotropy parameters. The spatial coherence radius was much smaller than that in atmospheric turbulence. These results are fundamental to understanding electromagnetic wave propagation in hypersonic turbulence.

  12. Infrared Spectra, Index of Refraction, and Optical Constants of Nitrile Ices Relevant to Titan's Atmosphere

    Science.gov (United States)

    Moore, Marla; Ferrante, Robert; Moore, William; Hudson, Reggie

    2010-01-01

    Spectra and optical constants of nitrite ices known or suspected to be in Titan's atmosphere are presented from 2.5 to 200 microns (4000 to 50 per cm ). These results are relevant to the ongoing modeling of Cassini CIRS observations of Titan's winter pole. Ices studied include: HCN, hydrogen cyanide; C2N2, cyanogen; CH3CN, acetonitrile; C 2H5CN, propionitrile; and HC3N, cyanoacetylene. For each of these molecules we report new measurements of the index of refraction, n, determined in both the amorphous- and crystallinephase at 670 nm. Spectra were measured and optical constants were calculated for each nitrite at a variety of temperatures including 20, 35, 50, 75, 95, and 110 K, in the amorphous- and crystalline-phase. This laboratory effort uses a dedicated FTIR spectrometer to record transmission spectra of thin-film ice samples. Laser interference is used to measure film thickness during condensation onto a transparent cold window attached to the tail section of a closed-cycle helium cryostat. Optical constants, real (n) and imaginary (k) refractive indices, are determined using Kramers-Kronig (K-K) analysis. Our calculation reproduces the complete spectrum, including all interference effects. Index of refraction measurements are made in a separate dedicated FTIR spectrometer where interference deposit fringes are measured using two 670 nm lasers at different angles to the ice substrate. A survey of these new measurements will be presented along with a discussion of their validation, errors, and application to Titan data.

  13. A complete parameterisation of the relative humidity and wavelength dependence of the refractive index of hygroscopic inorganic aerosol particles

    Directory of Open Access Journals (Sweden)

    M. I. Cotterell

    2017-08-01

    Full Text Available Calculations of aerosol radiative forcing require knowledge of wavelength-dependent aerosol optical properties, such as single-scattering albedo. These aerosol optical properties can be calculated using Mie theory from knowledge of the key microphysical properties of particle size and refractive index, assuming that atmospheric particles are well-approximated to be spherical and homogeneous. We provide refractive index determinations for aqueous aerosol particles containing the key atmospherically relevant inorganic solutes of NaCl, NaNO3, (NH42SO4, NH4HSO4 and Na2SO4, reporting the refractive index variation with both wavelength (400–650 nm and relative humidity (from 100 % to the efflorescence value of the salt. The accurate and precise retrieval of refractive index is performed using single-particle cavity ring-down spectroscopy. This approach involves probing a single aerosol particle confined in a Bessel laser beam optical trap through a combination of extinction measurements using cavity ring-down spectroscopy and elastic light-scattering measurements. Further, we assess the accuracy of these refractive index measurements, comparing our data with previously reported data sets from different measurement techniques but at a single wavelength. Finally, we provide a Cauchy dispersion model that parameterises refractive index measurements in terms of both wavelength and relative humidity. Our parameterisations should provide useful information to researchers requiring an accurate and comprehensive treatment of the wavelength and relative humidity dependence of refractive index for the inorganic component of atmospheric aerosol.

  14. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  15. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  16. Single-mode biological distributed feedback laser

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Maier-Flaig, Florian; Lemmer, Uli

    2013-01-01

    Single-mode second order distributed feedback (DFB) lasers of riboflavin (vitamin B2) doped gelatine films on nanostructured low refractive index material are demonstrated. Manufacturing is based on a simple UV nanoimprint and spin-coating. Emission wavelengths of 543 nm and 562 nm for two...

  17. Femtosecond laser-written double line waveguides in germanate and tellurite glasses

    Science.gov (United States)

    S. da Silva, Diego; Wetter, Niklaus U.; de Rossi, Wagner; Samad, Ricardo E.; Kassab, Luciana R. P.

    2018-02-01

    The authors report the fabrication and characterization of passive waveguides in GeO2-PbO and TeO2-ZnO glasses written with a femtosecond laser delivering pulses with 3μJ, 30μJ and 80fs at 4kHz repetition rate. Permanent refractive index change at the focus of the laser beam was obtained and waveguides were formed by two closely spaced laser written lines, where the light guiding occurs between them. The refractive index change at 632 nm is around 10-4 . The value of the propagation losses was around 2.0 dB/cm. The output mode profiles indicate multimodal guiding behavior. Raman measurements show structural modification of the glassy network. The results show that these materials are potential candidates for passive waveguides applications as low-loss optical components.

  18. Laser in situ keratomileusis for residual hyperopic astigmatism after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Aslanides, Ioannis M; Khoury, Aghlab N; Markomanolakis, Marinos M; Naoumidi, Tatiana; Pallikaris, loannis G

    2004-01-01

    To report a case of laser in situ keratomileusis (LASIK) in a patient with previous conductive keratoplasty. A 48-year-old man underwent conductive keratoplasty for low hyperopic astigmatism (manifest refraction OD: +2.25 -0.50 x 77 degrees; OS: +2.50 -0.50 x 105 degrees). Three months postoperatively, UCVA was 20/25 and BSCVA was 20/20 in both eyes; manifest refraction OD: -0.25 -0.75 x 110 degrees; OS: +0.75 -0.75 x 50 degrees. Sixteen months after the operation, regression of refractive outcome was (manifest) OD: +1.75 -1.25 x 90 degrees; OS: +2.50 -0.50 x 85 degrees; UCVA was 20/40 in the right eye and 20/63 in the left eye and BSCVA was 20/20 in both eyes. LASIK was performed for hyperopic regression in the left eye using an automated microkeratome (Alcon SKBM, 130-microm plate; Aesculap-Meditec MEL 70 excimer laser). LASIK was uneventful and no intraoperative or postoperative complications related to the previous conductive keratoplasty procedure or LASIK were observed. Three months after LASIK and 19 months after the initial conductive keratoplasty, the patient's left eye was emmetropic; UCVA was 20/20(-2), BSCVA was 20/20 and manifest refraction was +0.25 -0.25 x 35 degrees. There was a uniform increase in topographical steepening. Visual acuity, refraction and topographic findings remained unchanged at 6 months. Even though our experience is limited, treatment of hyperopia with LASIK in an eye with refractive regression following previous conductive keratoplasty resulted in a predicted refractive outcome, with no complications, and improvement in visual acuity at 6 months follow-up.

  19. Emmetropisation and the aetiology of refractive errors

    Science.gov (United States)

    Flitcroft, D I

    2014-01-01

    The distribution of human refractive errors displays features that are not commonly seen in other biological variables. Compared with the more typical Gaussian distribution, adult refraction within a population typically has a negative skew and increased kurtosis (ie is leptokurtotic). This distribution arises from two apparently conflicting tendencies, first, the existence of a mechanism to control eye growth during infancy so as to bring refraction towards emmetropia/low hyperopia (ie emmetropisation) and second, the tendency of many human populations to develop myopia during later childhood and into adulthood. The distribution of refraction therefore changes significantly with age. Analysis of the processes involved in shaping refractive development allows for the creation of a life course model of refractive development. Monte Carlo simulations based on such a model can recreate the variation of refractive distributions seen from birth to adulthood and the impact of increasing myopia prevalence on refractive error distributions in Asia. PMID:24406411

  20. UV laser-assisted fabrication of ridge waveguides in lithium niobate crystals

    OpenAIRE

    Sones, C.L.; Ying, C.Y.J.; Eason, R.W.; Mailis, S.; Ganguly, P.; Soergel, E.

    2010-01-01

    We present a UV laser-assisted method for the fabrication of ridge waveguides in lithium niobate. The UV laser irradiation step provides the refractive index change required for the vertical light confinement in the waveguide and also defines the ferroelectric domain pattern which produces the ridge structures after chemical etching.

  1. Laser subepithelial keratomileusis for myopia of -6 to -10 diopters with astigmatism with the MEL60 laser.

    Science.gov (United States)

    Bilgihan, Kamil; Hondur, Ahmet; Hasanreisoglu, Berati

    2004-01-01

    To evaluate the efficacy, predictability, and safety of laser subepithelial keratomileusis (LASEK) for treatment of high myopia with astigmatism. LASEK was performed in 61 eyes of 36 consecutive patients with myopic spherical equivalent refraction of -6.00 to -10.00 D using the Aesculap-Meditec MEL60 excimer laser. Data were collected prospectively with a follow-up of 6 to 17 months. Main outcome measures recorded were UCVA, BSCVA, residual refractive error, corneal haze, and complications. Ninety-six percent of eyes achieved 20/40 or better UCVA at 1 month. At 12 months, 64% of eyes achieved 20/20 and 92% achieved 20/40 or better UCVA. Two eyes lost 2 lines of BSCVA at 6 or 12 months. Accuracy of correction was +/- 0.50 D from emmetropia in 82% of eyes, and +/- 1.00 D in 90% at 12 months. No eye showed more than grade 1 haze. Grade 1 haze was observed in three eyes at 12 months. One patient had mild postoperative keratitis, which was successfully treated. LASEK with the Aesculap-Meditec MEL60 excimer laser appeared to be safe, effective, and highly predictable in treating high myopia.

  2. Glass laser discs with annular alkali lead borate coatings and use thereof

    International Nuclear Information System (INIS)

    Cooley, R.F.

    1975-01-01

    A laser assembly that includes a novel glass laser disc having an annular alkali lead borate glass coating for use in the assembly is disclosed. The annular coating has an index of refraction that is about 3 to 12 percent greater than the index of refraction of the laser disc, the thermal properties also being sufficiently matched with the glass laser disc so as to prevent the development of undesirable strains therein, the glass coating comprising a mixture of alkali metal oxides in which at least two different alkali metal oxides are present, and any K 2 O that is present is limited to an amount of not substantially more than about 1 percent by weight and an effective energy absorbing amount of heavy metal oxide that absorbs energy at a wavelength of about 1.06 microns to prevent parasitic oscillations. The heavy metal oxides include oxides of transition metals of the 3d, 4d, 4f, 5d and 5f orbital series. (auth)

  3. Tunability of optofluidic distributed feedback dye lasers

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Kristensen, Anders

    2007-01-01

    We investigate the tunability of optofluidic distributed feedback (DFB) dye lasers. The lasers rely on light-confinement in a nano-structured polymer film where an array of nanofluidic channels constitutes a third order Bragg grating DFB laser resonator with a central phase-shift. The lasers...... are operated by filling the DFB laser resonator with a dye solution by capillary action and optical pumping with a frequency doubled Nd: YAG laser. The low reflection order of the DFB laser resonator yields low out-of-plane scattering losses as well as a large free spectral range (FSR), and low threshold...... fluences down to similar to 7 mu J/mm2 are observed. The large FSR facilitates wavelength tuning over the full gain spectrum of the chosen laser dye and we demonstrate 45 nm tunability using a single laser dye by changing the grating period and dye solution refractive index. The lasers are straight...

  4. Atmospheric refraction : a history

    NARCIS (Netherlands)

    Lehn, WH; van der Werf, S

    2005-01-01

    We trace the history of atmospheric refraction from the ancient Greeks up to the time of Kepler. The concept that the atmosphere could refract light entered Western science in the second century B.C. Ptolemy, 300 years later, produced the first clearly defined atmospheric model, containing air of

  5. Combined application of prophylactic corneal cross-linking and laser in-situ keratomileusis - a review of literature.

    Science.gov (United States)

    Chan, Tommy C Y; Ng, Alex L K; Chan, Karen K W; Cheng, George P M; Wong, Ian Y H; Jhanji, Vishal

    2017-11-01

    Laser in-situ keratomileusis (LASIK) is safe and effective laser refractive procedures in treating refractive errors. However, regression of treatment and iatrogenic keratectasia remain to be a major concern, especially in treating thin cornea with high ametropia. Collagen cross-linking (CXL) is an effective method in stopping keratoconus progression through increasing the biomechanical strength of the cornea. Adjuvant cross-linking to refractive procedures can theoretically help prevent regression and reduce the risk of keratectasia development by increasing the mechanical stability of cornea. During the procedure, riboflavin is directly applied to the corneal stroma, thereby reducing the need of de-epithelialization as in the conventional protocol for keratoconus. Currently, there is still no consensus regarding the indication of CXL during refractive procedure, nor any standardized treatment protocol. This article aims to summarize the current evidence regarding the use of adjuvant CXL in LASIK. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Twistacene contained molecule for optical nonlinearity: Excited-state based negative refraction and optical limiting

    Science.gov (United States)

    Wu, Xingzhi; Xiao, Jinchong; Sun, Ru; Jia, Jidong; Yang, Junyi; Ao, Guanghong; Shi, Guang; Wang, Yuxiao; Zhang, Xueru; Song, Yinglin

    2018-06-01

    Spindle-type molecules containing twisted acenes (PyBTA-1 &PyBTA-2) are designed, synthesized characterized. Picosecond Z-scan experiments under 532 nm show reverse saturable absorption and negative nonlinear refraction, indicating large third-order optical nonlinearity in PyBTA-1. The mechanism of the optical nonlinearity is investigated and the results show that the nonlinear absorption and refraction in PyBTA-1 originates from a charge transfer (CT) state. Furthermore, relatively long lifetime and absorptive cross section of the CT state are measured. Based on the excited state absorption in PyBTA-1, strong optical limiting with ∼0.3 J/cm2 thresholds are obtained when excited by picoseconds and nanoseconds pulses. The findings on nonlinear optics suggest PyBTA-1 a promising material of all optical modulation and laser protection, which enrich the potential applications of these spindle-type molecules. Comparing to the previously reported spindle-type molecules with analogous structures, the introduction of ICT in PyBTA-1 &PyBTA-2 dramatically decreases the two-photon absorption while enhances the nonlinear refraction. The results could be used to selectively tailor the optical nonlinearity in such kind of compounds.

  7. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  8. Design of the nickel-like tin x-ray laser at 12.0 nm

    International Nuclear Information System (INIS)

    Yan Fei; Zhang Jie; Lu Xin; Zhong, Jia Y.

    2005-01-01

    The effects of the drive laser intensity, pulse duration, and pulse configuration on the performance of the Ni-like Sn x-ray laser at 12.0 nm (4d→4p, J=0→1) are investigated with use of a one-dimensional hydrodynamic code coupled with an atomic physics code. High gain operation is predicted for the optimized drive pulse configuration. The effects of refraction and saturation on the propagation of the x-ray laser in the plasma medium are also investigated by use of a two-dimensional ray-tracing code. The results show that the refraction plays an important role. The saturated output with an effective gain product length of 17.88 can be obtained for an ∼0.40-cm-long plasma column by use of optimized parameters

  9. The uncorrected refractive error challenge

    Directory of Open Access Journals (Sweden)

    Kovin Naidoo

    2016-11-01

    Full Text Available Refractive error affects people of all ages, socio-economic status and ethnic groups. The most recent statistics estimate that, worldwide, 32.4 million people are blind and 191 million people have vision impairment. Vision impairment has been defined based on distance visual acuity only, and uncorrected distance refractive error (mainly myopia is the single biggest cause of worldwide vision impairment. However, when we also consider near visual impairment, it is clear that even more people are affected. From research it was estimated that the number of people with vision impairment due to uncorrected distance refractive error was 107.8 million,1 and the number of people affected by uncorrected near refractive error was 517 million, giving a total of 624.8 million people.

  10. Electromagnetic numerical characterization of the laser-induced liquid crystal lens by finite-difference time domain method

    International Nuclear Information System (INIS)

    Morisaki, T.; Ono, H.

    2005-01-01

    A laser-induced liquid-crystal lens is formed by large optical non-linearity and anisotropic complex refractive indices in guest-host liquid crystals. We obtained light wave propagation characteristics of the laser-induced LC lens. Three analytical methods were used to obtain light wave propagation characteristics. Analysis by 3-dimensional heat conduction was applied to determine the refractive index in the liquid-crystal layer. Another method used was to determine light wave propagation characteristics in the laser-induced lens by means of the finite-difference tune domain (FDTD) method and diffraction theory. In this study, we draw a parallel between the experimental results and FDTD. Copyright (2003) AD-TECH - International Foundation for the Advancement of Technology Ltd

  11. Diplopia after laser in situ keratomileusis (LASIK) in a patient with a history of strabismus.

    Science.gov (United States)

    Heinmiller, Laura J; Wasserman, Barry N

    2013-02-01

    In patients with a history of strabismus, refractive surgery can result in decompensation of ocular alignment, with subsequent diplopia. Refractive surgery in the management of strabismus has been described, although it remains controversial. We present a young adult with past history of strabismus surgery and new-onset diplopia after refractive surgery. Binocular diplopia was treated surgically with laser in situ keratomileusis. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  12. EDITORIAL: Sensitive structures: refractive indices in nanotechnology Sensitive structures: refractive indices in nanotechnology

    Science.gov (United States)

    Demming, Anna

    2012-12-01

    Refractive index effects using nanoscale systems are frequently applied in new imaging, sensing and even visibility cloaking technology. In this issue, researchers in Japan use simulations and experiments to describe the confinement of optical vortices in nanoscale fin structures and the sensitivity of these systems to the refractive index of the surrounding media [1]. The effects of refraction as light rays pass between different media were recorded as long ago as the first century AD, by Ptolemy [2]. Over the following centuries the phenomena inspired Ibn Sahl in 984 [3], Thomas Harriot in 1602 [4], Willebrord Snellius in 1621 [5] and Rene Descartes in 1637 [6] to independently derive the more accurate and elegant equation for refraction so familiar to us today. Recent studies of the interactions between light and matter continue to reveal a wealth of phenomena that originate in the effects of the refractive indices of materials. Nanostructures can be used to manipulate conditions that affect the refractive indices of materials, such as temperature. A E Aliev et al at the University of Texas reported a striking demonstration of temperature-dependent refractive index effects using a free-standing, highly aligned carbon nanotube aerogel sheet [7]. They used the extremely low thermal capacitance and high heat transfer ability of transparent carbon nanotube sheets to enable high-frequency modulation of the sheet temperature over an enormous temperature range. The resulting sharp, rapidly changing gradient of the refractive index in the surrounding liquid or gas makes objects seem to disappear and can be used for visibility cloaking. Light-matter interaction resonances, where light is confined at the nanoscale, can be extremely sensitive to changes in the refractive index of the surrounding media [8], even allowing single-molecule detection [9]. Plasmons, the collective oscillations of electrons in response to incident light, are a typical example. Researchers at Rice

  13. Visual and Refractive Outcomes in Manual versus Femtosecond Laser-Assisted Cataract Surgery: A Single-Center Retrospective Cohort Analysis of 1838 Eyes.

    Science.gov (United States)

    Berk, Thomas A; Schlenker, Matthew B; Campos-Möller, Xavier; Pereira, Austin M; Ahmed, Iqbal Ike K

    2018-03-06

    Femtosecond laser-assisted cataract surgery (FLACS) has emerged as an alternative to manual cataract surgery (MCS) for corneal incision and capsulorhexis creation, as well as nuclear fragmentation. This study compares postoperative refractive and visual outcomes in eyes receiving MCS or FLACS. Single-center, comparative, retrospective cohort analysis. Consecutive eyes receiving FLACS and MCS from July 1, 2012, to July 31, 2015, at a single tertiary care center. Demographic data, ocular history, preoperative measurements and biometry, and postoperative surgical results were retrospectively obtained and statistically analyzed using a generalized linear mixed model adjusting for differences in baseline characteristics and within-patient correlation. A 2-tailed P value <0.05 was considered statistically significant throughout the study. Percentage of eyes achieving absolute error (AE) ≤0.5 diopters (D). Secondary outcomes included percentage of eyes with AE ≤0.25 D and ≤1.0 D, and percentage of distance-targeted eyes achieving uncorrected distance visual acuity (UDVA) of 20/20 or better, 20/25 or better, and 20/30 or better. A total of 883 eyes received MCS and 955 received FLACS among 1089 patients. Some 82.6% of FLACS eyes and 78.8% of MCS eyes had ≤0.5 D of AE at 3 weeks, representing an adjusted odds ratio (OR) of 1.28 (95% confidence interval [CI], 0.98-1.66) of FLACS relative to MCS being within target. Some 97.1% of FLACS and 97.2% of MCS eyes had ≤1.0 D of AE (OR, 0.96; 95% CI, 0.57-1.60) and 49.3% of FLACS and 46.3% of MCS eyes, ≤0.25 D of AE (OR, 1.13; 95% CI, 0.91-1.39). Factors predictive of a favorable refractive outcome included axial length between 22 and 24.8 mm, receiving a toric intraocular lens, less preoperative cylinder, and greater preoperative average keratometry. There was no significant difference in the percentage of patients targeted for distance who achieved UDVA of 20/20 or better (P = 0.30), 20/25 or better (P = 0.06), or 20

  14. Single-mode biological distributed feedback lasers based on vitamin B2 doped gelatin

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Maier-Flaig, F.; Lemmer, U.

    Biological second-order distributed feedback (DFB) lasers are presented. Riboflavin (vitamin B2) doped gelatin as active material is spin-coated onto nanoimprinted polymer with low refractive index. DFB grating periods of 368 nm and 384 nm yield laser emission at 543 nm and 562 nm, respectively....

  15. Review of technological advancements in calibration systems for laser vision correction

    Science.gov (United States)

    Arba-Mosquera, Samuel; Vinciguerra, Paolo; Verma, Shwetabh

    2018-02-01

    Using PubMed and our internal database, we extensively reviewed the literature on the technological advancements in calibration systems, with a motive to present an account of the development history, and latest developments in calibration systems used in refractive surgery laser systems. As a second motive, we explored the clinical impact of the error introduced due to the roughness in ablation and its corresponding effect on system calibration. The inclusion criterion for this review was strict relevance to the clinical questions under research. The existing calibration methods, including various plastic models, are highly affected by various factors involved in refractive surgery, such as temperature, airflow, and hydration. Surface roughness plays an important role in accurate measurement of ablation performance on calibration materials. The ratio of ablation efficiency between the human cornea and calibration material is very critical and highly dependent on the laser beam characteristics and test conditions. Objective evaluation of the calibration data and corresponding adjustment of the laser systems at regular intervals are essential for the continuing success and further improvements in outcomes of laser vision correction procedures.

  16. Influence of the apex angle of a hollow prism made from an ordinary commercial glass plate as a simple refractometer to the accuracy of the refractive index measurement of the edible oil

    Science.gov (United States)

    Idris, N.; Maswati; Yusibani, E.

    2018-05-01

    The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the

  17. Experimental studies of X-UV rays by a laser plasma: X-UV strioscopy by means of multilayer mirrors

    International Nuclear Information System (INIS)

    Lutrin, F.

    1996-01-01

    This thesis studies a new instrument -from its conception to the measures interpretation- that analyses electronic density gradient in the super critical transportation area of a laser plasma (0,35 μm). This device, so-called of X-UV Schlieren, is based on the refraction property of a probe beam by an index gradient. Its specificity is the use of the X-UV emission at 13 nm (92 eV) of another laser plasma as X-UV probe. The conception and characterization of this instrument are defined thanks to both the emissivity and reflectivity properties of laser plasmas and the reflectivity properties of multilayers. Within this report are presented strioscopy images, spatially and spectrally resolved of an aluminium plasma from a 3.10 12 W/cm 2 laser flux, probed by a 13 nm wavelength. The device has to be closely aligned so as to obtain good contrast and good spatial resolution. For the first time, the refraction of a X-UV probe beam by a laser plasma is displayed. The experiments show that this refraction is all the more obvious for a gold probe plasma of energy 105 J and an aluminium probed plasma of energy 1 J. According to our plasma hydrodynamic simulation, the detected refraction corresponds to an electronic density gradient of 6,5.10 25 electrons/cm 4 in the two first microns of the sur-critical area. To study the parameters dependence of this gradient in the sur-critical area, several solutions for improving the instrument are produced. (author)

  18. Effect of excimer laser (Arf, 193 nm) on aqueous humor during photorefractive keratectomy biophysical and biochemical study

    International Nuclear Information System (INIS)

    Mahmoud, S.S.; Mahmoud, A.A.

    2004-01-01

    Ultraviolet light (193 nm) produced by an excimer laser has been used to produce precise tissue ablation with minimal thermal damage to adjacent tissue. The present study was designed to investigate the effect of excimer laser during photo refractive keratectomy (PRK) on aqueous humor constituents and also the effect of antioxidant enzyme superoxide dismutase (SOD)- applied topically- on these changes if exist. Five groups of schenchilla rabbits were involved in this study, where four groups underwent corneal stromal ablation using argon fluoride excimer laser (Ar F, 193 nm). Two of these four groups were treated with superoxide dismutase intra operatively. The fifth group was used as control one. The obtained results revealed depletion of aqueous humor ascorbate and glutathione contents. Aqueous humor refractive index, cholesterol, phospholipids, malondialdehyde (MDA) and total protein were measured. In conclusion, the excimer laser can induce changes in aqueous humor constituents during PRK. These changes lasted at least for 24 hours and as the time increased to 4 weeks, these changes became limited. The use of exogenous SOD seems to exert beneficial effect on aqueous humor refractive index and total protein

  19. Negative refraction angular characterization in one-dimensional photonic crystals.

    Directory of Open Access Journals (Sweden)

    Jesus Eduardo Lugo

    2011-04-01

    Full Text Available Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs.By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone.Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  20. Negative refraction angular characterization in one-dimensional photonic crystals.

    Science.gov (United States)

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-04-06

    Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs. By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone. Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  1. Laser fusion project second annual report

    International Nuclear Information System (INIS)

    Dumbaugh, W.H.; Morgan, D.W.; Flannery, J.E.

    1978-01-01

    This research program is devoted to the preparation and characterization of fluoride glasses for laser fusion. The overall objective is to explore and characterize fluoride glass systems to find a glass with the lowest possible nonlinear refractive index, satisfactory chemical durability, and physical properties which enable coating large optical quality pieces

  2. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    Science.gov (United States)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  3. Keratocyte apoptosis and corneal antioxidant enzyme activities after refractive corneal surgery.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Adiguzel, U; Sezer, C; Yis, O; Akyol, G; Hasanreisoglu, B

    2002-01-01

    Refractive corneal surgery induces keratocyte apoptosis and generates reactive oxygen radicals (ROS) in the cornea. The purpose of the present study is to evaluate the correlation between keratocyte apoptosis and corneal antioxidant enzyme activities after different refractive surgical procedures in rabbits. Rabbits were divided into six groups. All groups were compared with the control group (Group 1), after epithelial scraping (Group 2), epithelial scrape and photorefractive keratectomy (PRK) (traditional PRK: Group 3), transepithelial PRK (Group 4), creation of a corneal flap with microkeratome (Group 5) and laser-assisted in situ keratomileusis (LASIK, Group 6). Terminal deoxyribonucleotidyl transferase-mediated dUTP-digoxigenin nick-end labelling assay (to detect DNA fragmentation in situ) and light microscopy were used to detect apoptosis in rabbit eyes. Glutathione peroxidase (Gpx) and superoxide dismutase (SOD) activities of the corneal tissues were measured with spectrophotometric methods. Corneal Gpx and SOD activities decreased significantly in all groups when compared with the control group (P<0.05) and groups 2, 3 and 6 showed a significantly higher amount of keratocyte apoptosis (P<0.05). Not only a negative correlation was observed between corneal SOD activity and keratocyte apoptosis (cc: -0.3648) but Gpx activity also showed negative correlation with keratocyte apoptosis (cc: -0.3587). The present study illustrates the negative correlation between keratocyte apoptosis and corneal antioxidant enzyme activities. This finding suggests that ROS may be partly responsible for keratocyte apoptosis after refractive surgery.

  4. Optical guiding and beam bending in free-electron lasers

    International Nuclear Information System (INIS)

    Scharlemann, E.T.

    1987-01-01

    The electron beam in a free-electron laser (FEL) can act as an optical fiber, guiding or bending the optical beam. The refractive and gain effects of the bunched electron beam can compensate for diffraction, making possible wigglers that are many Rayleigh ranges (i.e., characteristic diffraction lengths) long. The origin of optical guiding can be understood by examining gain and refractive guiding in a fiber with a complex index of refraction, providing a mathematical description applicable also to the FEL, with some extensions. In the exponential gain regime of the FEL, the electron equations of motion must be included, but a self-consistent description of exponential gain with diffraction fully included becomes possible. The origin of the effective index of refraction of an FEL is illustrated with a simple example of bunched, radiating dipoles. Some of the properties of the index of refraction are described. The limited experimental evidence for optical beam bending is summarized. The evidence does not yet provide conclusive proof of the existence of optical guiding, but supports the idea. Finally, the importance of refractive guiding for the performance of a high-gain tapered-wiggler FEL amplifier is illustrated with numerical simulations

  5. Heat accumulation regime of femtosecond laser writing in fused silica and Nd:phosphate glass

    Energy Technology Data Exchange (ETDEWEB)

    Bukharin, M.A. [Moscow Institute of Physics and Technology, Moscow Region (Russian Federation); Optosystems Ltd., Troitsk, Moscow (Russian Federation); Khudyakov, D.V. [Optosystems Ltd., Troitsk, Moscow (Russian Federation); Physics Instrumentation Center of the General Physics Institute, Troitsk, Moscow (Russian Federation); Vartapetov, S.K. [Physics Instrumentation Center of the General Physics Institute, Troitsk, Moscow (Russian Federation)

    2015-04-01

    We investigated refractive index induced by direct femtosecond laser writing inside fused silica and Nd:phosphate glass in heat accumulation regime. Spatial profile and magnitude of induced refractive index were investigated at various pulse repetition rates and translation velocities. It was shown that the magnitude of induced refractive index significantly rises with decreasing in time interval between successive laser pulses below the time for thermal diffusion. Going from nonthermal regime to heat accumulation regime, we achieved induced refractive index growth from 4 x 10{sup -3} up to 6.5 x 10{sup -3} in fused silica and from -6 x 10{sup -3} to -9 x 10{sup -3} in Nd:phosphate glass. Aspect ratio of treated area decreased from 2.1 down to less than 1.5 without correcting optical elements. It was shown that in heat accumulation regime, the treated area was surrounded by region of alternatively changed refractive index with significant magnitude up to -2 x 10{sup -3}. Wide regions of decreased refractive index enable fabrication of depressed cladding waveguides. We demonstrated low-loss (0.3 dB/cm) tubular waveguide inside fused silica. For orthogonal polarizations of guiding light, we achieved a small difference between losses as 0.1 dB/cm using highly symmetric written tracks forming the cladding. The desired structure was simulated with the beam propagation method, and the results were in good agreement with experiment data. (orig.)

  6. Intracavity Laser Refractometry In Reflection: Development And Implementation In Biomedical Investigations

    International Nuclear Information System (INIS)

    Gonchukov, S. A.

    2010-01-01

    The Intracavity Laser Refractometry in Reflection (ILRR) method is developed for precise investigation of the processes on an interface of different media in real time. This method is very attractive for the study of biological liquids. It is based on the control of two-mode phase-anisotropic laser spectrum. In the aggregate the values of the sensitivity, time of measuring, potential parameters of investigated media of ILRR method correspond to the best results in optical refractometry. The absolute value of refractive index correlates with the course of different diseases. It can serve the objective parameter for an estimation of a level of illness processes in organism and drug efficiency. In result of the investigation of the photoresponse of the blood to low-level laser irradiation both the slow thermal effect and fast biophysical effect were discovered. The refractive index behaviour in real time allows the photoacceptors and maximum therapeutic doses on organism, cellular, and molecular levels to be determined.

  7. Effects of small, intense laser spots on thin films

    International Nuclear Information System (INIS)

    Estabrook, K.

    1986-01-01

    Two-dimensional hydrodynamic simulations show that small diameter laser spots burn through flat foils considerably faster than larger spots. The physical mechanisms are (1) more nearly spherical divergence from the smaller spots which allows the debris to rapidly convect radially away from the small volume of laser heated plasma and (2) a variation on thermal self-focusing in which light is refracted into this volume, increasing the local heating rate

  8. Femtosecond laser writing of new type of waveguides in silver containing glasses (Conference Presentation)

    Science.gov (United States)

    Abou Khalil, Alain; Bérubé, Jean-Philippe; Danto, Sylvain; Desmoulin, Jean-Charles; Cardinal, Thierry; Petit, Yannick G.; Canioni, Lionel; Vallée, Réal

    2017-03-01

    Femtosecond laser writing in glasses is a growing field of research and development in photonics, since it provides a versatile, robust and efficient approach to directly address 3D material structuring. Laser-glass interaction process has been studied for many years, especially the local changes of the refractive index that have been classified by three distinct types (types I, II and III, respectively). These refractive index modifications are widely used for the creation of photonics devices such as waveguides [1], couplers, photonic crystals to fabricate integrated optical functions in glasses for photonic applications as optical circuits or integrated sensors. Femtosecond laser writing in a home-developed silver containing zinc phosphate glasses induces the creation of fluorescent silver clusters distributed around the laser-glass interaction voxel [2]. In this paper, we introduce a new type of refractive index modification in glasses. It is based on the creation of these photo-induced silver clusters allowing a local change in the refractive index Δn = 5×10-3, which is sufficient for the creation of waveguides and photonics devices. The wave guiding process in our glasses along these structures with original geometry is demonstrated for wavelengths from visible to NIR [3], giving a promising access to integrated optical circuits in these silver containing glasses. Moreover, the characterization of the waveguides is presented, including their original geometry, the refractive index change, the mode profile, the estimation of propagation losses and a comparison with simulation results. 1. K. M. Davis, K. Miura, N. Sugimoto, and K. Hirao, Opt. Lett. 21, 1729-1731 (1996). 2. M. Bellec, A. Royon, K. Bourhis, J. Choi, B. Bousquet, M. Treguer, T. Cardinal, J.-J. Videau, M. Richardson, and L. Canioni, The Journal of Physical Chemistry C 114, 15584-15588 (2010). 3. S. Danto, F. Désévédavy, Y. Petit, J.-C. Desmoulin, A. Abou Khalil, C. Strutynski, M. Dussauze, F

  9. Lasers as a tool for plasma diagnostics

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1981-01-01

    Lasers can be used as non-perturbative probes to measure many plasma parameters. Plasma refractivity is primarily a function of electron density, and interferometric measurements of phase changes with either pulsed or CW lasers can determine this parameter with spatial or temporal resolution over several orders of magnitude sensitivity by using laser wavelengths from the near uv to the far infrared. Laser scattering from free electrons yields the most fundamental electron temperature measurements in the plasma parameter range where individual scattering events are uncorrelated in phase and ion temperature or plasma wave and turbulence structure in the opposite limit. Laser scattering from bound electrons can be many orders of magnitude larger if the laser is matched to appropriate resonance frequencies and can be used in specialized circumstances for measuring low-ionized impurity or dominant species neutral concentrations and velocities

  10. Wave-vector and polarization dependence of conical refraction.

    Science.gov (United States)

    Turpin, A; Loiko, Yu V; Kalkandjiev, T K; Tomizawa, H; Mompart, J

    2013-02-25

    We experimentally address the wave-vector and polarization dependence of the internal conical refraction phenomenon by demonstrating that an input light beam of elliptical transverse profile refracts into two beams after passing along one of the optic axes of a biaxial crystal, i.e. it exhibits double refraction instead of refracting conically. Such double refraction is investigated by the independent rotation of a linear polarizer and a cylindrical lens. Expressions to describe the position and the intensity pattern of the refracted beams are presented and applied to predict the intensity pattern for an axicon beam propagating along the optic axis of a biaxial crystal.

  11. Development of terahertz laser diagnostics for electron density measurements.

    Science.gov (United States)

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2008-10-01

    A two color laser interferometer using terahertz laser sources is under development for high performance operation on the large helical device and for future burning plasma experiments such as ITER. Through investigation of terahertz laser sources, we have achieved high power simultaneous oscillations at 57.2 and 47.6 microm of a CH(3)OD laser pumped by a cw 9R(8) CO(2) laser line. The laser wavelength around 50 microm is the optimum value for future fusion devices from the consideration of the beam refraction effect and signal-to-noise ratio for an expected phase shift due to plasma. In this article, recent progress of the terahertz laser diagnostics, especially in mechanical vibration compensation by using a two color laser operation and terahertz laser beam transmission through a dielectric waveguide, will be presented.

  12. Variation of the refractive index for the active layer of the double heterostructure GaAlAsSb/GaInAsSb/GaAlAsSb in injected mode

    International Nuclear Information System (INIS)

    Mohou, M.A.

    1995-01-01

    This work reports on the influence of the injected current on the refractive index in the active layer of GaInAsSb/GaAlAsSb laser diodes. These diodes present at threshold a full beam width at half power θ perpendicular of about 52 deg. C. The fluctuation of the refractive index caused by the injection of free carriers was studied on the basis of the evolution of θ perpendicular as a function of the injected current. It was shown that the inversion of the population which follows the rising of the gain, causes a slight decrease of the refractive index. 12 refs, 5 figs

  13. Measuring the Dispersion in Laser Cavity Mirrors using White-Light Interferometry

    Science.gov (United States)

    2008-03-01

    mirrors. Two AlGaInP (aluminum gallium indium phosphide ) diode lasers are aligned such that one is polarized vertically while one is polarized...linear crystals, where the index of refraction depends on beam intensity. Short pulses with high peak intensities are well 14 suited to induce the...MEASURING THE DISPERSION OF LASER CAVITY MIRRORS USING WHITE-LIGHT INTERFEROMETRY THESIS Allison S

  14. Frequency Noise Properties of Lasers for Interferometry in Nanometrology

    Directory of Open Access Journals (Sweden)

    Ondřej Číp

    2013-02-01

    Full Text Available In this contribution we focus on laser frequency noise properties and their influence on the interferometric displacement measurements. A setup for measurement of laser frequency noise is proposed and tested together with simultaneous measurement of fluctuations in displacement in the Michelson interferometer. Several laser sources, including traditional He-Ne and solid-state lasers, and their noise properties are evaluated and compared. The contribution of the laser frequency noise to the displacement measurement is discussed in the context of other sources of uncertainty associated with the interferometric setup, such as, mechanics, resolution of analog-to-digital conversion, frequency bandwidth of the detection chain, and variations of the refractive index of air.

  15. Predictability and stability of refraction with increasing optical zone diameter in hyperopic LASIK

    Directory of Open Access Journals (Sweden)

    Mostafa A El-Helw

    2010-05-01

    Full Text Available Mostafa A El-Helw, Ahmed M EmarahCairo University, Cairo, EgyptObjective: We undertook a prospective nonrandomized study to assess refractive outcome and patient satisfaction with hyperopic laser in situ keratomileusis (LASIK using variable optical zone diameters in correction of hyperopia of more than 4.00 diopters.Methods: Fourteen adults (comprising 28 hyperopic eyes underwent hyperopic LASIK correction for hyperopia of more than 4.00 diopters. The sample was divided into two groups. Group 1 included the right eyes of the 14 patients who underwent hyperopic LASIK using a 6.5 mm optical zone diameter. Group 2 comprised the left eyes of the same patients with the only difference being that the optical zone diameter was 6.0 mm.Results: The mean age of the patients was 36.42 ± 5.10 years. Group 1 eyes had a median (range preoperative uncorrected visual acuity (UCVA of 0.79 (0.52 and best-corrected visual acuity (BCVA of 0.15 (0.08. Group 2 had a median preoperative UCVA of 0.79 (0.60 and BCVA of 0.15 (0.08. The median postoperative UCVA in Group 1 was 0.17 (0.21 and BCVA was 0.15 (0.13. In Group 2, the median postoperative UCVA was 0.30 (0.32 and BCVA was 0.15 (0.26. Group 1 had a median preoperative refraction of +5.37 (1.75 diopters and the median postoperative refraction at one week was −0.23 (1.25 diopters, at three months was +0.75 (0.75 diopters, and at six months was +0.75 (1.00 diopters. Group 2 had a median preoperative refraction of +5.00 (1.75 diopters, and the median postoperative refraction at one week was +0.13 (1.5 diopters, at three months was +1.00 (0.75 diopters and at six months +1.25 (1.25 diopters. The difference was statistically significant between groups 1 and 2. The difference within each group was also significant. Group 1 eyes were stabilizing after the three-month period in contrast with Group 2 in which the refractive changes continued throughout the follow-up period.Conclusion: Larger optical zone diameter in

  16. Role of the treating surgeon in the consent process for elective refractive surgery

    Directory of Open Access Journals (Sweden)

    Schallhorn SC

    2016-11-01

    Full Text Available Steven C Schallhorn,1–3 Stephen J Hannan,3 David Teenan,3 Julie M Schallhorn1 1Department of Ophthalmology, University of California, San Francisco, San Francisco, 2Roski Eye Institute, University of Southern California, Los Angeles, CA, USA; 3Optical Express, Glasgow, UK Purpose: To compare patient’s perception of consent quality, clinical and quality-of-life outcomes after laser vision correction (LVC and refractive lens exchange (RLE between patients who met their treating surgeon prior to the day of surgery (PDOS or on the day of surgery (DOS. Design: Retrospective, comparative case series. Setting: Optical Express, Glasgow, UK. Methods: Patients treated between October 2015 and June 2016 (3972 LVC and 979 RLE patients who attended 1-day and 1-month postoperative aftercare and answered a questionnaire were included in this study. All patients had a thorough preoperative discussion with an optometrist, watched a video consent, and were provided with written information. Patients then had a verbal discussion with their treating surgeon either PDOS or on the DOS, according to patient preference. Preoperative and 1-month postoperative visual acuity, refraction, preoperative, 1-day and 1-month postoperative questionnaire were compared between DOS and PDOS patients. Multivariate regression model was developed to find factors associated with patient’s perception of consent quality. Results: Preoperatively, 8.0% of LVC and 17.1% of RLE patients elected to meet their surgeon ahead of the surgery day. In the LVC group, 97.5% of DOS and 97.2% of PDOS patients indicated they were properly consented for surgery (P=0.77. In the RLE group, 97.0% of DOS and 97.0% of PDOS patients stated their consent process for surgery was adequate (P=0.98. There was no statistically significant difference between DOS and PDOS patients in most of the postoperative clinical or questionnaire outcomes. Factors predictive of patient’s satisfaction with consent quality

  17. Human resources for refraction services in Central Nepal.

    Science.gov (United States)

    Kandel, Himal; Murthy, G V S; Bascaran, Covadonga

    2015-07-01

    Uncorrected refractive error is a public health problem globally and in Nepal. Planning of refraction services is hampered by a paucity of data. This study was conducted to determine availability and distribution of human resources for refraction, their efficiency, the type and extent of their training; the current service provision of refraction services and the unmet need in human resources for refraction in Central Nepal. This was a descriptive cross-sectional study. All refraction facilities in the Central Region were identified through an Internet search and interviews of key informants from the professional bodies and parent organisations of primary eye centres. A stratified simple random sampling technique was used to select 50 per cent of refraction facilities. The selected facilities were visited for primary data collection. Face-to-face interviews were conducted with the managers and the refractionists available in the facilities using a semi-structured questionnaire. Data was collected in 29 centres. All the managers (n=29; response rate 100 per cent) and 50 refractionists (Response rate 65.8 per cent) were interviewed. Optometrists and ophthalmic assistants were the main providers of refraction services (n=70, 92.11 per cent). They were unevenly distributed across the region, highly concentrated around urban areas. The median number of refractions per refractionist per year was 3,600 (IQR: 2,400 - 6,000). Interviewed refractionists stated that clients' knowledge, attitude and practice related factors such as lack of awareness of the need for refraction services and/or availability of existing services were the major barriers to the output of refraction services. The total number of refractions carried out in the Central Region per year was 653,176. An additional 170 refractionists would be needed to meet the unmet need of 1,323,234 refractions. The study findings demand a major effort to develop appropriately trained personnel when planning

  18. Fully 3D refraction correction dosimetry system

    International Nuclear Information System (INIS)

    Manjappa, Rakesh; Makki, S Sharath; Kanhirodan, Rajan; Kumar, Rajesh; Vasu, Ram Mohan

    2016-01-01

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  19. Fully 3D refraction correction dosimetry system.

    Science.gov (United States)

    Manjappa, Rakesh; Makki, S Sharath; Kumar, Rajesh; Vasu, Ram Mohan; Kanhirodan, Rajan

    2016-02-21

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  20. The effect of silver on the optical, spectral-luminescent, and crystallization properties of bromide photo-thermo-refractive glasses

    Science.gov (United States)

    Oreshkina, K. V.; Dubrovin, V. D.; Ignat'ev, A. I.; Nikonorov, N. V.

    2017-10-01

    The effect of silver on the optical, spectral-luminescent, and crystallization properties of bromide photo-thermo-refractive glasses is studied. Multicomponent photosensitive glasses of the Na2O-ZnO-Al2O3-SiO2 system with photosensitizing agents (cerium, antimony, silver) and halogenides (fluorine and bromine) are synthesized. Ultraviolet irradiation and thermal treatment below the glass-transition temperature of the glasses cause the formation of silver molecular clusters, which exhibit luminescence in the visible and infrared regions. UV irradiation and thermal treatment of glasses above the glass-transition temperature lead to the growth of silver nanoparticles with plasmon resonance peak in the region of 420 nm. Further thermal treatment of glasses above the glass-transition temperature shifts the plasmon-resonance maximum by 70 nm to longer wavelengths, which is related to the growth of a crystalline shell consisting of mixed silver and sodium bromides on nanoparticles. This formation of a crystalline phase on colloidal centers results in a local increase in the refractive index of the irradiated region by +Δ n 900 ppm compared to the nonirradiated region. Photo-thermo-refractive glasses with increased silver concentration are promising photosensitive materials for creating holographic optical elements and devices for line narrowing and stabilizing filters, spectral beam combiners, and filters for increasing the spectral brightness of laser diodes. A positive change in the refractive index of Photo-thermo-refractive glasses provides the possibility of recording in them 3D waveguide and integrated-optical structures.

  1. Optical response of laser-doped silicon carbide for an uncooled midwave infrared detector.

    Science.gov (United States)

    Lim, Geunsik; Manzur, Tariq; Kar, Aravinda

    2011-06-10

    An uncooled mid-wave infrared (MWIR) detector is developed by doping an n-type 4H-SiC with Ga using a laser doping technique. 4H-SiC is one of the polytypes of crystalline silicon carbide and a wide bandgap semiconductor. The dopant creates an energy level of 0.30  eV, which was confirmed by optical spectroscopy of the doped sample. This energy level corresponds to the MWIR wavelength of 4.21  μm. The detection mechanism is based on the photoexcitation of electrons by the photons of this wavelength absorbed in the semiconductor. This process modifies the electron density, which changes the refractive index, and, therefore, the reflectance of the semiconductor is also changed. The change in the reflectance, which is the optical response of the detector, can be measured remotely with a laser beam, such as a He-Ne laser. This capability of measuring the detector response remotely makes it a wireless detector. The variation of refractive index was calculated as a function of absorbed irradiance based on the reflectance data for the as-received and doped samples. A distinct change was observed for the refractive index of the doped sample, indicating that the detector is suitable for applications at the 4.21  μm wavelength.

  2. Anatase phase stability and doping concentration dependent refractivity in codoped transparent conducting TiO2 films

    International Nuclear Information System (INIS)

    Chen, T L; Furubayashi, Y; Hirose, Y; Hitosugi, T; Shimada, T; Hasegawa, T

    2007-01-01

    Nb 0.06 Sn x Ti 0.94-x O 2 (x ≤ 0.3) thin films were grown by a pulsed-laser deposition method with varying Sn concentration. Through a combinatorial technique, we find that Sn concentration can reach a maximum of about x = 0.3 while maintaining the stable anatase phase and epitaxy. A doping concentration dependence of the refractivity is revealed, in which refractivity reduction at a wavelength of λ = 500 nm is estimated to be 12.4% for Nb 0.06 Sn 0.3 Ti 0.64 O 2 thin film. Sn doping induced band-gap blue shift can be contributed to the mixing of extended Sn 5s orbitals with the conduction band of TiO 2 . Low resistivity on the order of 10 -4 Ω cm at room temperature and high internal transmittance of more than 95% in the visible light region are exhibited for Nb 0.06 Sn x Ti 0.94-x O 2 thin films (x ≤ 0.2). Optical and transport analyses demonstrate that doping Sn into Nb 0.06 Ti 0.94 O 2 can reduce the refractivity while maintaining low resistivity and high transparency

  3. Dark refraction shift with allowance for astigmatism

    Directory of Open Access Journals (Sweden)

    W.D.H. Gillan

    2005-12-01

    Full Text Available Purpose: To show that the dark refraction shift (dark focus is a more complicated phenomenon than implied when presented as spherical. Methods: Fifty autorefractor measurements of refractive state of the right eye were obtained in light  and  dark  conditions.  Multivariate  methods were used to analyze the data and stereo-pair scat-ter plots, polar meridional profiles and other means of presenting results are used to show important characteristics of the dark refraction shift. Results: The complexity of the dark refrac-tion shift is indicated by stereo-pair scatter plots showing the amount of stigmatic and antistigmatic variation that occurs in light and dark conditions. The mean dark refraction shift is presented in a complete manner including all three components of refractive state. The greater variance and covari-ance under dark conditions is clearly shown by the term-by-term dark-light variance-covariance ratio and polar profiles  of variance and covariance.Conclusions: The  dark  refraction  shift  is  a more complicated phenomenon than implied by representations as purely spherical in nature.

  4. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers.

    Science.gov (United States)

    Gazieva, Lola; Beer, Mette Hjuler; Nielsen, Kim; Hjortdal, Jesper

    2011-12-01

    To compare the visual refractive outcome and complication of laser in situ keratomileusis (LASIK) carried out with a Carl Zeiss-Meditec MEL-70 Excimer laser and a MEL-80 laser for treatment of high myopia. Journal records of 680 consecutive eyes that underwent LASIK with a Schwind Supratome microkeratome and a MEL-70 Excimer laser (Group A), or a Moria M2 microkeratome and a MEL-80 Excimer laser (Group B) were reviewed. Manifest refraction, uncorrected and best spectacle-corrected visual acuity (BSCVA), corneal topography and central corneal thickness (CCT) were recorded before and 3 months after treatment. Pre- and postoperative complications, visual and refractive outcome and frequency of retreatments were registered. Mean preoperative spherical equivalent refraction was -8.52 dioptres (-5.50- -18 dioptres), and the mean attempted laser correction was -8.02 dioptres (-5.50- -11 dioptres). Three months after LASIK, the average treatment error (difference between achieved and attempted correction) was 1.20 (SD=1.19) dioptres of under correction in Group A and 0.52 (SD=1.00) dioptres in Group B. Four eyes lost more than two lines of BSCVA (0.6%). In 110 eyes (16%), a re-LASIK procedure was performed to reduce remaining myopia after the primary procedure. Laser in situ keratomileusis treatment for high myopia can effectively reduce high degrees of myopia. Under correction was observed in both treatment groups but Group B has a slightly better predictability. Significant loss of BSCVA occurs infrequently after LASIK for even considerable grades of myopia (0.6% in each group). © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  5. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  6. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali; Alshuhail, Abdulrahman Abdullatif Abdulrahman; Hanafy, Sherif

    2012-01-01

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green's functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  7. Predicting Refractive Surgery Outcome: Machine Learning Approach With Big Data.

    Science.gov (United States)

    Achiron, Asaf; Gur, Zvi; Aviv, Uri; Hilely, Assaf; Mimouni, Michael; Karmona, Lily; Rokach, Lior; Kaiserman, Igor

    2017-09-01

    To develop a decision forest for prediction of laser refractive surgery outcome. Data from consecutive cases of patients who underwent LASIK or photorefractive surgeries during a 12-year period in a single center were assembled into a single dataset. Training of machine-learning classifiers and testing were performed with a statistical classifier algorithm. The decision forest was created by feature vectors extracted from 17,592 cases and 38 clinical parameters for each patient. A 10-fold cross-validation procedure was applied to estimate the predictive value of the decision forest when applied to new patients. Analysis included patients younger than 40 years who were not treated for monovision. Efficacy of 0.7 or greater and 0.8 or greater was achieved in 16,198 (92.0%) and 14,945 (84.9%) eyes, respectively. Efficacy of less than 0.4 and less than 0.5 was achieved in 322 (1.8%) and 506 (2.9%) eyes, respectively. Patients in the low efficacy group (differences compared with the high efficacy group (≥ 0.8), yet were clinically similar (mean differences between groups of 0.7 years, of 0.43 mm in pupil size, of 0.11 D in cylinder, of 0.22 logMAR in preoperative CDVA, of 0.11 mm in optical zone size, of 1.03 D in actual sphere treatment, and of 0.64 D in actual cylinder treatment). The preoperative subjective CDVA had the highest gain (most important to the model). Correlations analysis revealed significantly decreased efficacy with increased age (r = -0.67, P big data from refractive surgeries may be of interest. [J Refract Surg. 2017;33(9):592-597.]. Copyright 2017, SLACK Incorporated.

  8. Refractive index and solubility control of para-cymene solutions for index-matched fluid-structure interaction studies

    Science.gov (United States)

    Fort, Charles; Fu, Christopher D.; Weichselbaum, Noah A.; Bardet, Philippe M.

    2015-12-01

    To deploy optical diagnostics such as particle image velocimetry or planar laser-induced fluorescence (PLIF) in complex geometries, it is beneficial to use index-matched facilities. A binary mixture of para-cymene and cinnamaldehyde provides a viable option for matching the refractive index of acrylic, a common material for scaled models and test sections. This fluid is particularly appropriate for large-scale facilities and when a low-density and low-viscosity fluid is sought, such as in fluid-structure interaction studies. This binary solution has relatively low kinematic viscosity and density; its use enables the experimentalist to select operating temperature and to increase fluorescence signal in PLIF experiments. Measurements of spectral and temperature dependence of refractive index, density, and kinematic viscosity are reported. The effect of the binary mixture on solubility control of Rhodamine 6G is also characterized.

  9. Refractive index modulation in the polyurethane films containing diazo sulfonamide chromophores

    Energy Technology Data Exchange (ETDEWEB)

    Ortyl, E. [Insitute of Organic and Polymer Technology, WrocIaw University of Technology, 50-384 WrocIaw (Poland); Kucharski, S. [Insitute of Organic and Polymer Technology, WrocIaw University of Technology, 50-384 WrocIaw (Poland)]. E-mail: stanislaw.kucharski@pwr.wroc.pl; Gotszalk, T. [Faculty of Microsystem Electronics and Photonics, WrocIaw University of Technology, 50-384 WrocIaw (Poland)

    2005-05-23

    The series of photochromic polyurethanes was obtained by modification of precursor polymers prepared from 4,4'-diphenylmethane diisocyanate (MDI), hexamethylene 1,6-diisocyanate (HDI) or toluene 2,4-diisocyanate (TDI) and N,N'-di-(2-hydroxyethyl) aniline. The precursor polymers were functionalized by an azo-coupling reaction to form the polymers with different degrees of functionalization and various heterocyclic sulfonamide groups. Ellipsometric measurements showed a decrease of the refractive index during illumination of thin polymer films with white light. The change of real part of the refractive index was in the range of 0.0033-0.0296 depending on the polymer kind and chromophore content. It was found that photocurrent was generated in the polymer films deposited onto indium tin oxide (ITO) glass plates. For the polyurethanes containing sulfathiazole groups in side chains the current density was up to 180 nA/cm{sup 2}. The formation of diffraction grating in the polymer films was easily achieved using linearly polarized laser light (532 nm) in a standard two beam coupling (TBC) system. The diffraction efficiency of the first diffraction beam was dependent on the chromophore content reaching ca. 12% for the derivatives of sulfamethoxazole.

  10. Experimental study of X-ray emission in laser-cluster interaction; Etude experimentale de l'emission X issue de l'interaction laser-agregats

    Energy Technology Data Exchange (ETDEWEB)

    Caillaud, T

    2004-09-01

    Rare gas cluster jets are an intermediate medium between solid and gas targets. Laser-cluster jets interaction may generate a great number of energetic particles as X-rays, UV, high harmonics, ions, electrons and neutrons. To understand all the mechanisms involved in such an interaction we need to make a complete study of individual cluster response to an ultra-short laser pulse. We studied the laser interaction with our argon cluster gas jet, which is well characterized in cluster size and density, to enlarge the knowledge of this interaction. We measured absorption, heating and X-ray emission spectra versus laser parameters and clusters size ({approx} 15-30 nm). We show that there is a strong refraction effect on laser propagation due to the residual gas density. This effect was confirmed by laser propagation simulation with a cylindrical 2-dimensional particle code WAKE. The role played by refraction was to limit maximum laser intensity on the focal spot and to increase interaction volume. By this way, X-ray emission was observed with laser intensity not so far from the ionization threshold (few 10{sup 14} W.cm{sup -2}). We also studied plasma expansion both at cluster scale and focal volume scale and deduced the deposited energy distribution as a function of time. Thanks to a simple hydrodynamic model, we used these results to study cluster expansion. X-ray emission is then simulated by TRANSPEC code in order to reproduce X-ray spectra and duration. Those results revealed an extremely brief X-ray emission consistent with a preliminary measure by streak camera (on ps scale). (author)

  11. Laser experiments in light cloudiness with the geostationary satellite ARTEMIS

    Science.gov (United States)

    Kuzkov, V.; Kuzkov, S.; Sodnik, Z.

    2016-08-01

    The geostationary satellite ARTEMIS was launched in July 2001. The satellite is equipped with a laser communication terminal, which was used for the world's first inter-satellite laser communication link between ARTEMIS and the low earth orbit satellite SPOT-4. Ground-to-space laser communication experiments were also conducted under various atmospheric conditions involving ESA's optical ground station. With a rapidly increasing volume of information transferred by geostationary satellites, there is a rising demand for high-speed data links between ground stations and satellites. For ground-to-space laser communications there are a number of important design parameters that need to be addressed, among them, the influence of atmospheric turbulence in different atmospheric conditions and link geometries. The Main Astronomical Observatory of NAS of Ukraine developed a precise computer tracking system for its 0.7 m AZT-2 telescope and a compact laser communication package LACES (Laser Atmosphere and Communication experiments with Satellites) for laser communication experiments with geostationary satellites. The specially developed software allows computerized tracking of the satellites using their orbital data. A number of laser experiments between MAO and ARTEMIS were conducted in partial cloudiness with some amount of laser light observed through clouds. Such conditions caused high break-up (splitting) of images from the laser beacon of ARTEMIS. One possible explanation is Raman scattering of photons on molecules of a water vapor in the atmosphere. Raman scattering causes a shift in a wavelength of the photons.In addition, a different value for the refraction index appears in the direction of the meridian for the wavelength-shifted photons. This is similar to the anomalous atmospheric refraction that appears at low angular altitudes above the horizon. We have also estimated the atmospheric attenuation and the influence of atmospheric turbulence on observed results

  12. Refracting surface plasmon polaritons with nanoparticle arrays

    DEFF Research Database (Denmark)

    Radko, I.P.; Evlyukhin, A.B.; Boltasseva, Alexandra

    2008-01-01

    Refraction of surface plasmon polaritons (SPPs) by various structures formed by a 100-nm-period square lattice of gold nanoparticles on top of a gold film is studied by leakage radiation microscopy. SPP refraction by a triangular-shaped nanoparticle array indicates that the SPP effective refractive...... to design nanoparticle arrays for specific applications requiring in-plane SPP manipulation....

  13. Refractive Outcomes, Contrast Sensitivity, HOAs, and Patient Satisfaction in Moderate Myopia: Wavefront-Optimized Versus Tissue-Saving PRK.

    Science.gov (United States)

    Nassiri, Nader; Sheibani, Kourosh; Azimi, Abbas; Khosravi, Farinaz Mahmoodi; Heravian, Javad; Yekta, Abasali; Moghaddam, Hadi Ostadi; Nassiri, Saman; Yasseri, Mehdi; Nassiri, Nariman

    2015-10-01

    To compare refractive outcomes, contrast sensitivity, higher-order aberrations (HOAs), and patient satisfaction after photorefractive keratectomy for correction of moderate myopia with two methods: tissue saving versus wavefront optimized. In this prospective, comparative study, 152 eyes (80 patients) with moderate myopia with and without astigmatism were randomly divided into two groups: the tissue-saving group (Technolas 217z Zyoptix laser; Bausch & Lomb, Rochester, NY) (76 eyes of 39 patients) or the wavefront-optimized group (WaveLight Allegretto Wave Eye-Q laser; Alcon Laboratories, Inc., Fort Worth, TX) (76 eyes of 41 patients). Preoperative and 3-month postoperative refractive outcomes, contrast sensitivity, HOAs, and patient satisfaction were compared between the two groups. The mean spherical equivalent was -4.50 ± 1.02 diopters. No statistically significant differences were detected between the groups in terms of uncorrected and corrected distance visual acuity and spherical equivalent preoperatively and 3 months postoperatively. No statistically significant differences were seen in the amount of preoperative to postoperative contrast sensitivity changes between the two groups in photopic and mesopic conditions. HOAs and Q factor increased in both groups postoperatively (P = .001), with the tissue-saving method causing more increases in HOAs (P = .007) and Q factor (P = .039). Patient satisfaction was comparable between both groups. Both platforms were effective in correcting moderate myopia with or without astigmatism. No difference in refractive outcome, contrast sensitivity changes, and patient satisfaction between the groups was observed. Postoperatively, the tissue-saving method caused a higher increase in HOAs and Q factor compared to the wavefront-optimized method, which could be due to larger optical zone sizes in the tissue-saving group. Copyright 2015, SLACK Incorporated.

  14. Solar pumped lasers: Work in progress at the University of Chicago

    Science.gov (United States)

    Winston, Roland

    Of the variety of solar energy conversion schemes that have been explored, the conversion of solar flux to coherent laser radiation is relatively new. Solar flux at sufficiently high concentrations to overcome threshold for the really important laser materials has not been available. This technological inhibition has recently been overcome through the application of nonimaging optics through the demonstration of concentration levels of 84,000 suns at the University of Chicago in a refractive medium (sapphire) and of over 20,000 suns in air at the Solar Energy Research Institute High Flux Facility. A thermodynamic overview is presented of solar lasers including solid state lasers and dye lasers.

  15. Excimer laser corneal surgery and free oxygen radicals.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Akata, F; Hasanreisoğlu, B; Türközkan, N

    1996-01-01

    Corneal photoablation with 193 nm argon fluoride excimer laser is a new technique for the treatment of refractive errors and for removing corneal opacities and irregularities. Ultraviolet radiation and thermal injury induce free radical formation in the tissues. The aim of this study was to confirm the production of free radicals by excimer laser photoablation in rabbits. The thermal changes of the posterior corneal surface were recorded during excimer laser photoablation. The lipid peroxide (LPO) levels and superoxide dismutase (SOD) activities of aqueous humour were measured after excimer laser keratectomy. The aqueous LPO levels were not changed after excimer laser ablation, but both the thermal increase in the cornea during the photoablation and the decreased aqueous SOD activities suggest that free radicals are formed in the cornea during excimer laser keratectomy, and that they may be responsible for some of the complications of excimer laser corneal surgery.

  16. The Theory for the Dielectric Slab Waveguide with Complex Refractive Index Applied to GaAs Lasers

    DEFF Research Database (Denmark)

    Buus, Jens

    1977-01-01

    In this paper we investigate the homogeneous dielectric slab waveguide in the case of complex dielectric constants. A method for calculating the field distribution in a dielectric waveguide with an arbitrary symmetrical variation in the refractive index is developed, and some of the results are p...

  17. Propagation of highly aberrated laser beams in nonquadratic plasma waveguides

    International Nuclear Information System (INIS)

    Feit, M.D.; Fleck, J.A. Jr.; Morris, J.R.

    1977-01-01

    The propagation of a laser beam in a plasma column several meters long with a realistic electron density distribution is examined. The electron density distribution is based on laser-beam heating at z=0, but is otherwise uncoupled to the laser beam. The aberrated nature of the resulting lenslike medium leads to essentially aperiodic beam properties, which contrast with the completely periodic properties of Gaussian beams propagating in quadratic lenslike media. The beam is nonetheless stably trapped. These aberrated-beam properties also help to stabilize the beam against axial variations in refractive index

  18. Saturated output tabletop x-ray lasers

    International Nuclear Information System (INIS)

    Dunn, J.; Osterheld, A.L.; Nilsen, J.; Hunter, J.R.; Li, Y.; Faenov, A.Ya.; Pikuz, T.A.; Shlyaptsev, N.

    2000-01-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion x-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (Compact Multipulse Terawatt) laser system at the Lawrence Livermore National Laboratory (LLNL) have produced several x-ray lasers operating in the saturation regime. Output energy of 10-15 (micro)J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d → 4p transition at 147 (angstrom) with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the x-ray laser output

  19. Saturated output tabletop X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J.; Osterheld, A.L.; Nilsen, J.; Hunter, J.R. [Lawrence Livermore National Lab., CA (United States); Yuelin Li [Lawrence Livermore National Lab., CA (United States); ILSA, Lawrence Livermore National Lab., Livermore, CA (United States); Faenov, A.Ya.; Pikuz, T.A. [Lawrence Livermore National Lab., CA (United States); MISDC of VNIIFTRI, Mendeleevo (Russian Federation); Shlyaptsev, V.N. [Lawrence Livermore National Lab., CA (United States); DAS, Univ. of California Davis-Livermore, Livermore, CA (United States)

    2001-07-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion X-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (compact multipulse terawatt) laser system at the Lawrence livermore national laboratory (LLNL) have produced several X-ray lasers operating in the saturation regime. Output energy of 10-15 {mu}J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d{yields}4p transition at 147 A with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the X-ray laser output. (orig.)

  20. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  1. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  2. The generalized vectorial laws of reflection and refraction

    International Nuclear Information System (INIS)

    Bhattacharjee, Pramode Ranjan

    2005-01-01

    This paper discloses two important discoveries. These are: (i) discovery of ambiguity in the well-established laws of reflection and refraction of light which have been in regular use for many years, and (ii) discovery of generalized vectorial laws of reflection and refraction of light. The existing definitions of angle of incidence, angle of reflection and angle of refraction are considered first. Each of these definitions is found to be ambiguous, not in compliance with the fundamental definition of angle in geometry. Two typical questions (one in the case of reflection and the other for refraction) have been addressed, which cannot be dealt with by using the existing laws of reflection and refraction of light. Thus, the existing laws of reflection and refraction of light seem to be ambiguous in respect of generality and their validity in a broad sense is questionable. With a view to removing the ambiguities, proper definitions of the above three angles are given first and then the statement of the generalized vectorial law of reflection (as well as that of refraction) has been offered

  3. Laser interferometry in length measurement. Proceedings. Laserinterferometrie in der Laengenmesstechnik. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    Wavelength-stabilized lasers for length measurement, measurements of the refractive index of air, laser interferometers, acceptance tests of laser interferometer systems, the Michelson interferometer with semiconductor laser, and the state of the art of optical gyroscopes for angular position measurement are described in the general section. The examples of laser interferometer applications in production engineering comprise automatic acceptance testing of coordinate measuring systems, simultaneous laser measurements of the position and the pitching, yansing and rolling angles along a measuring line, a 3D-interferometer length measuring system, the calibration of standard measures, angular position measurements, straightness measurements, and laser interferometers as installed length measuring systems in machine tools and measuring machinery. There are no separate records of the 13 lectures presented at the meeting. (DG).

  4. Optofluidic third order distributed feedback dye laser

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Kristensen, Anders

    2006-01-01

    which has a refractive index lower than that of the polymer. In combination with a third order DFB grating, formed by the array of nanofluidic channels, this yields a low threshold for lasing. The laser is straightforward to integrate on lab-on-a-chip microsystems where coherent, tunable light......This letter describes the design and operation of a polymer-based third order distributed feedback (DFB) microfluidic dye laser. The device relies on light confinement in a nanostructured polymer film where an array of nanofluidic channels is filled by capillary action with a liquid dye solution...

  5. Interface characteristics of peeling-off damages of laser coatings

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Yun, E-mail: coating@siom.ac.cn; Yi, Kui; Guohang, Hu; Shao, Jianda

    2014-01-30

    Coating stacks of HfO{sub 2}/SiO{sub 2} and Ta{sub 2}O{sub 5}/SiO{sub 2} were separately prepared by electron beam evaporation and dual ion beam sputtering. Damage characteristics at the interlayer interfaces were analyzed after irradiation of the coatings by a 1064 nm laser. The cross-sectional morphologies of damage spots indicated that peeling-off damages always occurred at the interface where the low refractive index material (SiO{sub 2}) was deposited on the high refractive index material (HfO{sub 2} or Ta{sub 2}O{sub 5}). The effects of interface microstructure and components on peeling-off damages were also discussed. The microstructure of the interface was not a major factor that influenced peeling-off damages. Incomplete oxides (SiO{sub x}) and Na, K, Li ions accumulated near the interface and caused the formation of micro-defects layers with nano-sized thicknesses. Micro-defects layers maybe reduced adhesion of different interfaces and formed plasmas by absorbing laser energy. Finally stripping damages happened from micro-defects layers during irradiation by a 1064 nm laser.

  6. Physics of negative refractive index materials

    International Nuclear Information System (INIS)

    Ramakrishna, S Anantha

    2005-01-01

    In the past few years, new developments in structured electromagnetic materials have given rise to negative refractive index materials which have both negative dielectric permittivity and negative magnetic permeability in some frequency ranges. The idea of a negative refractive index opens up new conceptual frontiers in photonics. One much-debated example is the concept of a perfect lens that enables imaging with sub-wavelength image resolution. Here we review the fundamental concepts and ideas of negative refractive index materials. First we present the ideas of structured materials or meta-materials that enable the design of new materials with a negative dielectric permittivity, negative magnetic permeability and negative refractive index. We discuss how a variety of resonance phenomena can be utilized to obtain these materials in various frequency ranges over the electromagnetic spectrum. The choice of the wave-vector in negative refractive index materials and the issues of dispersion, causality and energy transport are analysed. Various issues of wave propagation including nonlinear effects and surface modes in negative refractive materials (NRMs) are discussed. In the latter part of the review, we discuss the concept of a perfect lens consisting of a slab of a NRM. This perfect lens can image the far-field radiative components as well as the near-field evanescent components, and is not subject to the traditional diffraction limit. Different aspects of this lens such as the surface modes acting as the mechanism for the imaging of the evanescent waves, the limitations imposed by dissipation and dispersion in the negative refractive media, the generalization of this lens to optically complementary media and the possibility of magnification of the near-field images are discussed. Recent experimental developments verifying these ideas are briefly covered

  7. Alterações motoras após cirurgia refrativa no paciente estrábico Motor disturbances after refractive surgery in patients with strabismus

    Directory of Open Access Journals (Sweden)

    Rosana Nogueira Pires da Cunha

    2004-06-01

    Full Text Available OBJETIVO: Estudar a evolução clínica de pacientes com estrabismo e que se submeteram à cirurgia refrativa. MÉTODOS: Foram examinados 15 pacientes de outubro de 2000 a setembro de 2001 com história de estrabismo e cirurgia fotorrefrativa, incluindo avaliação sensório-motora. O tempo de seguimento foi no mínimo de 6 meses da correção a laser. Os pacientes que já haviam sido submetidos à correção a laser constituíram o primeiro grupo, e os que foram examinados antes da correção a laser, formaram o segundo grupo. RESULTADOS: Todos os pacientes do primeiro grupo necessitaram de cirurgia corretora de estrabismo para aliviar os sintomas de visão dupla ou corrigirem o aumento do desvio ocular. A cirurgia fotorrefrativa foi realizada nesses casos em pacientes com estrabismo pré-existente e sem avaliação prévia de suas condições sensoriais.A maioria dos pacientes do segundo grupo apresentou piora da visão binocular após o procedimento a laser. Metade dos pacientes desse grupo precisou usar óculos para detalhes de perto para aliviar sintomas de astenopia. Aqueles que possuíam esotropia acomodativa foram os que apresentaram menos ou nenhuma queixa após o procedimento, e a evolução foi estável ao longo dos meses de pós-operatório. CONCLUSÕES: Os cirurgiões refrativos devem selecionar seus pacientes, evitando subestimar alterações que possam comprometer a capacidade de fusão após o laser. Recomendamos a avaliação sensório-motora detalhada, antes do laser, para todos os candidatos à cirurgia refrativa.PURPOSE: To evaluate patients with strabismus submitted to excimer laser refractive procedure. METHODS: Complete eye examination was performed, including motor and sensorial evaluation in 15 patients from October, 2000 to September, 2001. Follow-up was at least 6 months after excimer laser procedure. Patients who had been submitted to laser were named the first group and those who were seen before laser formed the

  8. Refractive accuracy with light-adjustable intraocular lenses.

    Science.gov (United States)

    Villegas, Eloy A; Alcon, Encarna; Rubio, Elena; Marín, José M; Artal, Pablo

    2014-07-01

    To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). University Hospital Virgen de la Arrixaca, Murcia, Spain. Prospective nonrandomized clinical trial. Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (Plight adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Refractive index contrast in porous silicon multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Nava, R.; Mora, M.B. de la; Tagueena-Martinez, J. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Rio, J.A. del [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Centro Morelense de Innovacion y Transferencia Tecnologica, Consejo de Ciencia y Tecnologia del Estado de Morelos (Mexico)

    2009-07-15

    Two of the most important properties of a porous silicon multilayer for photonic applications are flat interfaces and a relative large refractive index contrast between layers in the optical wavelength range. In this work, we studied the effect of the current density and HF electrolyte concentration on the refractive index of porous silicon. With the purpose of increasing the refractive index contrast in a multilayer, the refractive index of porous silicon produced at low current was studied in detail. The current density applied to produce the low porosity layers was limited in order to keep the electrolyte flow through the multilayer structure and to avoid deformation of layer interfaces. We found that an electrolyte composed of hydrofluoric acid, ethanol and glycerin in a ratio of 3:7:1 gives a refractive index contrast around 1.3/2.8 at 600 nm. Several multilayer structures with this refractive index contrast were fabricated, such as dielectric Bragg mirrors and microcavities. Reflectance spectra of the structures show the photonic quality of porous silicon multilayers produced under these electrochemical conditions. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Development of a subjective refraction simulator

    Science.gov (United States)

    Perches, S.; Ares, J.; Collados, M. V.

    2013-11-01

    We have developed simulation software by Matlab (MathworksInc.) with a graphical interface designed for non-expert users. This simulator allows you to complete the process of subjective refraction starting from the aberrometry of the patients and analyse the influence of different factors during the exam. In addition to explain the graphical interface and its working, we show two examples about a complete process of subjective refraction with the influence of high order aberrations and without them showing the retinal image obtained in each step of the refraction process. When the Jackson Cross-Cylinder technique is made with this software, it becomes clear the difficulty of chosen between two images when high order aberrations are present. Therefore, the variability of response during the refraction can be a problem when the examiner has to reach an adequate optical prescription.

  11. Isaac Newton and the astronomical refraction.

    Science.gov (United States)

    Lehn, Waldemar H

    2008-12-01

    In a short interval toward the end of 1694, Isaac Newton developed two mathematical models for the theory of the astronomical refraction and calculated two refraction tables, but did not publish his theory. Much effort has been expended, starting with Biot in 1836, in the attempt to identify the methods and equations that Newton used. In contrast to previous work, a closed form solution is identified for the refraction integral that reproduces the table for his first model (in which density decays linearly with elevation). The parameters of his second model, which includes the exponential variation of pressure in an isothermal atmosphere, have also been identified by reproducing his results. The implication is clear that in each case Newton had derived exactly the correct equations for the astronomical refraction; furthermore, he was the first to do so.

  12. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai; AlTheyab, Abdullah; Schuster, Gerard T.

    2014-01-01

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place

  13. Femtosecond laser cataract surgery: technology and clinical practice.

    Science.gov (United States)

    Roberts, Timothy V; Lawless, Michael; Chan, Colin Ck; Jacobs, Mark; Ng, David; Bali, Shveta J; Hodge, Chris; Sutton, Gerard

    2013-03-01

    The recent introduction of femtosecond lasers to cataract surgery has generated much interest among ophthalmologists around the world. Laser cataract surgery integrates high-resolution anterior segment imaging systems with a femtosecond laser, allowing key steps of the procedure, including the primary and side-port corneal incisions, the anterior capsulotomy and fragmentation of the lens nucleus, to be performed with computer-guided laser precision. There is emerging evidence of reduced phacoemulsification time, better wound architecture and a more stable refractive result with femtosecond cataract surgery, as well as reports documenting an initial learning curve. This article will review the current state of technology and discuss our clinical experience. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  14. Nonlinear refractive index measuring using a double-grating interferometer in pump–probe configuration and Fourier transform analysis

    International Nuclear Information System (INIS)

    Rasouli, Saifollah; Ghorbani, Mahnaz

    2012-01-01

    In this paper, we have presented a simple, stable, highly sensitive and timesaving method based on a double-grating interferometer in conjunction with a pump–probe technique for measuring the nonlinear refractive index. A pump laser beam is aligned collinearly with an expanded plane parallel probe beam by a dichroic mirror. These beams pass through the sample, while right behind the sample using a suitable bandpass filter the pump beam is intercepted. The distorted probe beam then passes through a double-grating interferometer. One of the lateral shearing interference patterns is recorded by use of a CCD camera and, after digitization, has been stored in a computer. The interference pattern is analyzed by means of a Fourier transform algorithm. The refractive index changes have been obtained from phase distribution of the recorded fringe patterns. The implementation of the technique is straightforward and the arrangement is very simple and stable yet its sensitivity is comparable with other interferometry methods. It is also not a time consuming method. The method is applied for measuring the thermal nonlinear refractive index n 2 of colloidal gold nanoparticles in water solution. (paper)

  15. High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Dufva, Martin; Kristensen, Anders

    2015-01-01

    imaging refractometry without moving parts is presented. DFB dye lasers are low-cost and highly sensitive refractive index sensors. The unique multi-wavelength DFB laser structure presented here comprises several areas with different grating periods. Imaging in two dimensions of space is enabled...... by analyzing laser light from all areas in parallel with an imaging spectrometer. With this multi-resonance imaging refractometry method, the spatial position in one direction is identified from the horizontal, i.e., spectral position of the multiple laser lines which is obtained from the spectrometer charged...

  16. OH spectroscopy with frequency-doubled dye laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    ter Meulen, J J

    1979-01-01

    Discusses the excitation of the OH radical by UV radiation for the determination of the hyperfine structure of the excited states. The 307 nm UV light is obtained by doubling the frequency (in double-refraction crystals) of a tunable dye laser. Details of the laser set-up are given. The method is suitable for application to other high-resolution molecular spectroscopy experiments in the area between 200 and 400 nm. Further extensions can be expected with ring compound dyes and external doubling of the frequency.

  17. Advanced personalized nomogram for myopic laser surgery: First 100 eyes

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; van der Linden, Jan Willem; van der Meulen, Ivanka J. E.; Nieuwendaal, Carla P.

    2008-01-01

    PURPOSE: To report the results in the first 100 eyes treated for myopia using a new advanced nomogram. SETTING: Private refractive surgery clinic. METHODS: This prospective interventional case series comprised 58 patients (100 eyes) consecutively treated for myopia with laser in situ keratomileusis

  18. Relationship between refractive error and ocular biometrics in twin children: the Guangzhou Twin Eye Study.

    Science.gov (United States)

    Wang, Decai; Liu, Bin; Huang, Shengsong; Huang, Wenyong; He, Mingguang

    2014-09-01

    A cross-sectional study was conducted to explore the relationship between refractive error and ocular biometrics in children from the Guangzhou twin eye study. Twin participants aged 7-15 years were selected from Guangzhou Twin Eye Study. Ocular examinations included visual acuity measurement, ocular motility evaluation, autorefraction under cycloplegia, and anterior segment, media, and fundus examination. Axial length (AL), anterior chamber depth (ACD), and corneal curvature radius were measured using partial coherence laser interferometry. A multivariate linear regression model was used for statistical analysis. Twin children from Guangzhou city showed a decreased spherical equivalent with age, whereas both AL and ACD were increased and corneal curvature radius remained unchanged. When adjusted by age and gender, the data from 77% of twins presenting with spherical equivalent changes indicated that these were caused by predictable variables (R2 = 0.77, P biometrics. Refractive status is largely determined by axial length as the major factor.

  19. Use of visible-laser-diode fiber optic sensors in the beverage industry and environmental controls

    Science.gov (United States)

    Pham, Van Hoi; Chu, Dinh T.; Bui, Huy; Tran, Viet L.

    1997-01-01

    The fiber-optic refractometer using visible laser diodes with wavelengths of 650 divided by 670 nm for the liquid refractive-index measurement is presented. The refractive- index measures by fiber-optic sensors of the connected configuration for different liquids with refractive indices from 1.33 to 1.5 have given the accuracy of 5.10-3. The fiber-optic refractometer was performanced for the distinguish of the salt or sugar content in the mixtures with range of 10-3 and 5.10-4, respectively. These refractometers are already to use for the sugar control systems of beverage industry and salt-water environment.

  20. Analysis on second operation after laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Wen-Xuan Pei

    2015-07-01

    Full Text Available AIM: To observe clinical effects between the laser in situ keratomileusis(LASIKsurgery and the laser subepithelial keratomileusis(LASEKsurgery as the second operation after an unsuccessful LASIK surgery. METHODS:Forty-nine patients(98 eyeswith refractive regression after LASIK operation received the second surgery. All patients were divided into two groups: group A and B. Group A(48 eyes of 24 patientsreceived LASIK surgery and group B(50 eyes of 25 patientsreceived LASEK surgery. Inspect the main parameters included visual acuity, refraction, corneal curvature, and the total value of high-aberration after 1wk, 1mo and 1a, t-test of groups was used as statistical analysis method.RESULTS: There was statistically significant(PP>0.05. There developed one case of epithelium in growth after LASIK surgery, and one case of haze Ⅱ after LASEK surgery. CONCLUSION: Both LASIK and LASEK surgery can obtain satisfactory therapeutic results after an unsuccessful LASIK surgery.

  1. Refractive index of silica aerogel: Uniformity and dispersion law

    International Nuclear Information System (INIS)

    Bellunato, T.; Calvi, M.; Matteuzzi, C.; Musy, M.; Perego, D.L.; Storaci, B.

    2008-01-01

    Two methods for the measurement of the uniformity of the refractive index n within a single block of silica aerogel are described. One is based on the deflection of a laser beam induced by transverse index gradients. The second exploits the Cherenkov effect, measuring the emission angle of photons radiated by 500 MeV electrons traversing the aerogel. The beam can scan the full aerogel surface providing information on point to point variations of n. The measurement of the dispersion law n(λ) is also reported. An Xe lamp coupled to a diffraction grating provides the monochromatic source. The index for each λ is measured by the prism method at a corner of an aerogel sample. A Sellmeier functional form for n(λ) is assumed, and the parameters best fitting the experimental data are given

  2. Nonlinear laser pulse response in a crystalline lens.

    Science.gov (United States)

    Sharma, R P; Gupta, Pradeep Kumar; Singh, Ram Kishor; Strickland, D

    2016-04-01

    The propagation characteristics of a spatial Gaussian laser pulse have been studied inside a gradient-index structured crystalline lens with constant-density plasma generated by the laser-tissue interaction. The propagation of the laser pulse is affected by the nonlinearities introduced by the generated plasma inside the crystalline lens. Owing to the movement of plasma species from a higher- to a lower-temperature region, an increase in the refractive index occurs that causes the focusing of the laser pulse. In this study, extended paraxial approximation has been applied to take into account the evolution of the radial profile of the Gaussian laser pulse. To examine the propagation characteristics, variation of the beam width parameter has been observed as a function of the laser power and initial beam radius. The cavitation bubble formation, which plays an important role in the restoration of the elasticity of the crystalline lens, has been investigated.

  3. The refractive index of relic gravitons

    CERN Document Server

    Giovannini, Massimo

    2016-01-01

    The dynamical evolution of the refractive index of the tensor modes of the geometry produces a specific class of power spectra characterized by a blue (i.e. slightly increasing) slope which is directly determined by the competition of the slow-roll parameter and of the rate of variation of the refractive index. Throughout the conventional stages of the inflationary and post-inflationary evolution, the microwave background anisotropies measurements, the pulsar timing limits and the big-bang nucleosythesis constraints set stringent bounds on the refractive index and on its rate of variation. Within the physically allowed region of the parameter space the cosmic background of relic gravitons leads to a potentially large signal for the ground based detectors (in their advanced version) and for the proposed space-borne interferometers. Conversely, the lack of direct detection of the signal will set a qualitatively new bound on the dynamical variation of the refractive index.

  4. Simultaneous determination of ordinary and extraordinary refractive index dispersions of nematic liquid crystals in the visible and near-infrared regions from an interference spectrum

    Science.gov (United States)

    Ozaki, Ryotaro; Nishi, Koji; Kan, Takayuki; Kadowaki, Kazunori

    2016-10-01

    An improved interference method is proposed to determine ordinary and extraordinary refractive index dispersions of nematic liquid crystals (LCs). In this method, an LC cell coated with a thin metal layer is used as a Fabry-Perot interferometer, which shows us a sharp transmission fringe. To ensure high reliability, the wavelength dispersion of the refractive index of the metal is taken into account in fitting calculation. In spite of measuring ordinary and extraordinary components, the LC cell, polarizers, and other equipment are not rotated during the experiment. The index evaluation from a single spectrum avoids errors depending on the measurement position owing to non-uniformities of molecular orientation and cell thickness because we can obtain the two indices at exactly the same position. This system can adapt to a wide frequency range and does not require any specific wavelength light source or laser. We demonstrate the determination of ordinary and extraordinary refractive index dispersions of a nematic liquid crystal in the visible and near-infrared regions. Furthermore, we quantitatively reproduce the measured spectrum by calculation using the measured refractive indices.

  5. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  6. Laser propagation and compton scattering in parabolic plasma channel

    CERN Document Server

    Dongguo, L; Yokoya, K; Hirose, T

    2003-01-01

    A Gaussian laser beam propagating in a parabolic plasma channel is discussed in this paper. For a weak laser, plasma density perturbation induced by interaction between the laser field and plasma is very small, the refractive index can be assumed to be constant with respect to time variable. For a parabolic plasma channel, through the static propagation equation, we obtain an analytical solution of the profile function of the Gaussian laser beam for an unmatched case and give the general condition for the matched case. As the laser intensity increases, an effect due to strong laser fields is included. We discuss how to design and select the distribution of plasma density for a certain experiment in which a plasma channel is utilized to guide a laser beam. The number of scattered photons (X-rays) generated through Compton backscattering in a plasma channel is discussed. (author)

  7. Reflective and refractive objects for mixed reality.

    Science.gov (United States)

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  8. Refractive error magnitude and variability: Relation to age.

    Science.gov (United States)

    Irving, Elizabeth L; Machan, Carolyn M; Lam, Sharon; Hrynchak, Patricia K; Lillakas, Linda

    2018-03-19

    To investigate mean ocular refraction (MOR) and astigmatism, over the human age range and compare severity of refractive error to earlier studies from clinical populations having large age ranges. For this descriptive study patient age, refractive error and history of surgery affecting refraction were abstracted from the Waterloo Eye Study database (WatES). Average MOR, standard deviation of MOR and astigmatism were assessed in relation to age. Refractive distributions for developmental age groups were determined. MOR standard deviation relative to average MOR was evaluated. Data from earlier clinically based studies with similar age ranges were compared to WatES. Right eye refractive errors were available for 5933 patients with no history of surgery affecting refraction. Average MOR varied with age. Children <1 yr of age were the most hyperopic (+1.79D) and the highest magnitude of myopia was found at 27yrs (-2.86D). MOR distributions were leptokurtic, and negatively skewed. The mode varied with age group. MOR variability increased with increasing myopia. Average astigmatism increased gradually to age 60 after which it increased at a faster rate. By 85+ years it was 1.25D. J 0 power vector became increasingly negative with age. J 45 power vector values remained close to zero but variability increased at approximately 70 years. In relation to comparable earlier studies, WatES data were most myopic. Mean ocular refraction and refractive error distribution vary with age. The highest magnitude of myopia is found in young adults. Similar to prevalence, the severity of myopia also appears to have increased since 1931. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  9. Scanning mid-IR laser apparatus with eye tracking for refractive surgery

    Science.gov (United States)

    Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.

    1999-06-01

    A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.

  10. Femtosecond laser writing of waveguides in zinc phosphate glasses [Invited

    NARCIS (Netherlands)

    Fletcher, L.B.; Witcher, J.J.; Troy, N.; Reis, S.T.; Brow, R.K.; Martinez Vazquez, R.; Osellame, R.; Krol, D.M.

    2011-01-01

    We have studied the relationship between the initial glass composition and the structural changes associated with laser-induced refractive index modification in a series of Er-Yb doped and undoped zinc phosphate glasses. White light microscopy and waveguide experiments are used together with Raman

  11. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei

    2017-02-14

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N geophones evenly deployed along the line. These two reciprocal shots contain approximately 2N refraction travel times, which can be spawned into O(N2) refraction travel times by an interferometric transformation. Then, these virtual refraction travel times are used with a source wavelet to create N virtual refraction shot gathers, which are the input data for wave-equation travel-time inversion. Numerical results show that the parsimonious wave-equation travel-time tomogram has about the same accuracy as the tomogram computed by standard wave-equation travel-time inversion. The most significant benefit is that a reciprocal survey is far less time consuming than the standard refraction survey where a source is excited at each geophone location.

  12. Microstructured optical fiber refractive index sensor

    DEFF Research Database (Denmark)

    Town, Graham E.; McCosker, Ravi; Yuan, Scott Wu

    2010-01-01

    We describe a dual-core microstructured optical fiber designed for refractive index sensing of fluids. We show that by using the exponential dependence of intercore coupling on analyte refractive index, both large range and high sensitivity can be achieved in the one device. We also show...

  13. Refraction in the lower troposphere: Higher order image distortion effects due to refractive profile curvature

    Science.gov (United States)

    Short, Daniel J.

    There are many applications that rely on the propagation of light through the atmosphere - all of which are subject to atmospheric conditions. While there are obvious processes such as scattering due to particulates like clouds and dust that affect the received intensity of the radiation, the clear atmosphere can also cause significant effects. Refraction is a clear air effect that can cause a variety of phenomena such as apparent relocation, stretching and compression of objects when viewed through the atmosphere. Recently, there has been significant interest in studying the refractive effects for low angle paths within the troposphere, and in particular, near-horizontal paths in the Earth's boundary layer, which is adjacent to the ground. Refractive effects in this case become problematic for many terrestrial optical applications. For example, the pointing of a free space optical communication or a remote sensing system can suffer wandering effects, high-resolution imagery can present distorted and/or dislocated targets, optical tracking of targets can be inaccurate, and optical geodetic surveying accuracy is also very sensitive to the effects of refraction. The work in this dissertation was inspired by data from a time-lapse camera system that collects images of distant targets over a near-horizontal path along the ground. This system was used previously to study apparent diurnal image displacement and this dissertation extends that work by exploring the higher order effects that result from curvature in the vertical refractive index profile of the atmosphere. There are surprisingly few experiments involving atmospheric refractive effects that carefully correlate field data to analytical expressions and other factors such as meteorological data. In working with the time-lapse data, which is comprised of sequences of hundreds or thousands of images collected over durations of weeks or months, it is important to develop straightforward analysis techniques that can

  14. Solid state lasers: a major direction in quantum electronics

    International Nuclear Information System (INIS)

    Shcherbakov, I.A.

    2004-01-01

    The aim of the report is to analyze development of solid-state lasers (SSL) as one of the most important avenues of the quantum electronics. The obtained intensity of a laser radiation at the focus equal to 5x10 1 0 W/cm 2 (the field intensity equal to about 5x10 1 0 V/cm 2 ) is noted to enable to observe nonlinear quantum- electrodynamic effects. Besides, one managed to increase the SSL efficiency conventionally equal to maximum 3% up to 48-50%. Paper describes new types of SSLs, namely, the crystalline fiber lasers with the lateral gradient of the index of refraction [ru

  15. Synthesis and stabilization of oxide-based colloidal suspensions in organic media: application in the preparation of hybrids organic-inorganic materials for very high laser damage threshold coatings

    International Nuclear Information System (INIS)

    Marchet, N.

    2008-02-01

    Multilayer coatings are widely used in optic and particular in the field of high power laser on the components of laser chains. The development of a highly reflective coating with a laser damage resistance requires the fine-tuning of a multilayer stack constituted by a succession alternated by materials with low and high refractive index. In order to limit the number of layers in the stack, refractive indexes must be optimized. To do it, an original approach consists in synthesizing new organic-inorganic hybrid materials satisfying the criteria of laser damage resistance and optimized refractive index. These hybrid materials are constituted by nano-particles of metal oxides synthesized by sol-gel process and dispersed in an organic polymer with high laser damage threshold. Nevertheless, this composite system requires returning both compatible phases between them by chemical grafting of alc-oxy-silanes or carboxylic acids. We showed that it was so possible to disperse in a homogeneous way these functionalized nano-particles in non-polar, aprotic solvent containing solubilized organic polymers, to obtain time-stable nano-composite solutions. From these organic-inorganic hybrid solutions, thin films with optical quality and high laser damage threshold were obtained. These promising results have permitted to realize highly reflective stacks, constituted by 7 pairs with optical properties in agreement with the theoretical models and high laser damage threshold. (author)

  16. Composite polymer: Glass edge cladding for laser disks

    Science.gov (United States)

    Powell, H.T.; Wolfe, C.A.; Campbell, J.H.; Murray, J.E.; Riley, M.O.; Lyon, R.E.; Jessop, E.S.

    1987-11-02

    Large neodymium glass laser disks for disk amplifiers such as those used in the Nova laser require an edge cladding which absorbs at 1 micrometer. This cladding prevents edge reflections from causing parasitic oscillations which would otherwise deplete the gain. Nova now utilizes volume-absorbing monolithic-glass claddings which are fused at high temperature to the disks. These perform quite well but are expensive to produce. Absorbing glass strips are adhesively bonded to the edges of polygonal disks using a bonding agent whose index of refraction matches that of both the laser and absorbing glass. Optical finishing occurs after the strips are attached. Laser disks constructed with such claddings have shown identical gain performance to the previous Nova disks and have been tested for hundreds of shots without significant degradation. 18 figs.

  17. Composite polymer-glass edge cladding for laser disks

    Science.gov (United States)

    Powell, Howard T.; Riley, Michael O.; Wolfe, Charles R.; Lyon, Richard E.; Campbell, John H.; Jessop, Edward S.; Murray, James E.

    1989-01-01

    Large neodymium glass laser disks for disk amplifiers such as those used in the Nova laser require an edge cladding which absorbs at 1 micrometer. This cladding prevents edge reflections from causing parasitic oscillations which would otherwise deplete the gain. Nova now utilizes volume-absorbing monolithic-glass claddings which are fused at high temperature to the disks. These perform quite well but are expensive to produce. Absorbing glass strips are adhesively bonded to the edges of polygonal disks using a bonding agent whose index of refraction matches that of both the laser and absorbing glass. Optical finishing occurs after the strips are attached. Laser disks constructed with such claddings have shown identical gain performance to the previous Nova disks and have been tested for hundreds of shots without significant degradation.

  18. Laser streaming: Turning a laser beam into a flow of liquid.

    Science.gov (United States)

    Wang, Yanan; Zhang, Qiuhui; Zhu, Zhuan; Lin, Feng; Deng, Jiangdong; Ku, Geng; Dong, Suchuan; Song, Shuo; Alam, Md Kamrul; Liu, Dong; Wang, Zhiming; Bao, Jiming

    2017-09-01

    Transforming a laser beam into a mass flow has been a challenge both scientifically and technologically. We report the discovery of a new optofluidic principle and demonstrate the generation of a steady-state water flow by a pulsed laser beam through a glass window. To generate a flow or stream in the same path as the refracted laser beam in pure water from an arbitrary spot on the window, we first fill a glass cuvette with an aqueous solution of Au nanoparticles. A flow will emerge from the focused laser spot on the window after the laser is turned on for a few to tens of minutes; the flow remains after the colloidal solution is completely replaced by pure water. Microscopically, this transformation is made possible by an underlying plasmonic nanoparticle-decorated cavity, which is self-fabricated on the glass by nanoparticle-assisted laser etching and exhibits size and shape uniquely tailored to the incident beam profile. Hydrophone signals indicate that the flow is driven via acoustic streaming by a long-lasting ultrasound wave that is resonantly generated by the laser and the cavity through the photoacoustic effect. The principle of this light-driven flow via ultrasound, that is, photoacoustic streaming by coupling photoacoustics to acoustic streaming, is general and can be applied to any liquid, opening up new research and applications in optofluidics as well as traditional photoacoustics and acoustic streaming.

  19. The refractive index of human hemoglobin in the visible range

    International Nuclear Information System (INIS)

    Zhernovaya, O; Tuchin, V; Sydoruk, O; Douplik, A

    2011-01-01

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l -1 . This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l -1 . The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  20. Negative Refraction Angular Characterization in One-Dimensional Photonic Crystals

    OpenAIRE

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-01-01

    Background Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity de...

  1. A Longitudinal Study on the Effects of Laser Refractive Eye Surgery in Military Aircrew

    National Research Council Canada - National Science Library

    Hinton, Patricia; Niall, Keith K; Wainberg, Dan; Bateman, Bill; Courchesne, Cyd; Gray, Gary; Quick, Gayle; Thatcher, Bob

    2005-01-01

    .... Postoperative low contrast acuity has improved with newer laser techniques but there was still concern that vision after laser eye surgery would be not good enough for military aircrew demands...

  2. Abnormal optical anisotropy in correlated disorder KTa1-xNbxO3:Cu with refractive index gradient.

    Science.gov (United States)

    Zhang, Xin; He, Shan; Zhao, Zhuan; Wu, Pengfei; Wang, Xuping; Liu, Hongliang

    2018-02-13

    In this report, an abnormal optical anisotropy in KTa 1-x Nb x O 3 :Cu (Cu:KTN) crystals with refractive index gradient is presented. Contrary to general regulation in a cross-polarization setup, the transmitted intensity of both TE (horizontally polarized) and TM (vertically polarized) lasers aligned with the basic crystallographic directions can be modulated quasiperiodically. The mechanism is supposed to be based on the polarization induced by the temperature gradient and the refractive index gradient. Meanwhile, the correlated disorder property of the crystals in the range of the freezing temperature (T f ) and the intermediate temperature (T  * ) also plays an important role. With the results verified both theoretically and experimentally, we believe this work is not only beneficial for the development of the theory associated with the correlated disorder structures in relaxor ferroelectrics, but also significant for the exploitation of numerous optical functional devices.

  3. Refractive-index determination of solids from first- and second-order critical diffraction angles of periodic surface patterns

    International Nuclear Information System (INIS)

    Meichner, Christoph; Kador, Lothar; Schedl, Andreas E.; Neuber, Christian; Kreger, Klaus; Schmidt, Hans-Werner

    2015-01-01

    We present two approaches for measuring the refractive index of transparent solids in the visible spectral range based on diffraction gratings. Both require a small spot with a periodic pattern on the surface of the solid, collimated monochromatic light, and a rotation stage. We demonstrate the methods on a polydimethylsiloxane film (Sylgard ® 184) and compare our data to those obtained with a standard Abbe refractometer at several wavelengths between 489 and 688 nm. The results of our approaches show good agreement with the refractometer data. Possible error sources are analyzed and discussed in detail; they include mainly the linewidth of the laser and/or the angular resolution of the rotation stage. With narrow-band light sources, an angular accuracy of ±0.025 ∘ results in an error of the refractive index of typically ±5 ⋅ 10 −4 . Information on the sample thickness is not required

  4. Experimental Determination of Refractive Index of Gas Hydrates

    DEFF Research Database (Denmark)

    Bylov, Martin; Rasmussen, Peter

    1997-01-01

    . For methane hydrate (structure I) the refractive index was found to be 1.346 and for natural gas hydrate (structure II) it was found to be 1.350. The measurements further suggest that the gas hydrate growth rate increases if the water has formed hydrates before. The induction time, on the other hand, seems......The refractive indexes of methane hydrate and natural gas hydrate have been experimentally determined. The refractive indexes were determined in an indirect manner making use of the fact that two non-absorbing materials will have the same refractive index if they cannot be distinguished visually...

  5. Characterizing conical refraction optical tweezers

    Science.gov (United States)

    McDonald, C.; McDougall, C.; Rafailov, E.; McGloin, D.

    2014-12-01

    Conical refraction occurs when a beam of light travels through an appropriately cut biaxial crystal. By focussing the conically refracted beam through a high numerical aperture microscope objective, conical refraction optical tweezers can be created, allowing for particle manipulation in both Raman spots and in the Lloyd/Poggendorff rings. We present a thorough quantification of the trapping properties of such a beam, focussing on the trap stiffness and how this varies with trap power and trapped particle location. We show that the lower Raman spot can be thought of as a single-beam optical gradient force trap, while radiation pressure dominates in the upper Raman spot, leading to optical levitation rather than trapping. Particles in the Lloyd/Poggendorff rings experience a lower trap stiffness than particles in the lower Raman spot but benefit from rotational control.

  6. UV Laser Diagnostics of the 1-MA Z-pinch Plasmas

    International Nuclear Information System (INIS)

    Altemara, S. D.; Ivanov, V. V.; Astanovitskiy, A. L.; Haboub, A.

    2009-01-01

    The 532 nm laser diagnostic set at the Zebra generator shows the details of the ablation and stagnation phases in cylindrical, planar, and star-like wire arrays but it cannot show the structure of the stagnated z-pinch and the implosion in small diameter loads, 1-3 mm in diameter. The absorption increment and the refraction angle of the 532 nm laser, when passing through the plasma, are too great to obtain quality images. An ultraviolet probing beam at the wavelength of 266 nm was developed to study small-diameter loads and to investigate the structure of the 1-MA z-pinch. The UV radiation has a much smaller absorption increment and refraction angles in plasmas than the 532 nm light and allows for better imaging of the z-pinch plasmas. Estimates showed that UV probing would be able to probe the high-density z-pinch plasma in experiments on the Zebra generator, and the early results of UV probing on the Zebra generator have shown promise.

  7. Refractive Errors Affect the Vividness of Visual Mental Images

    Science.gov (United States)

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  8. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan

    2015-11-23

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  9. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan; Fu, Qiang; Amata, Hadi; Su, Shuochen; Heide, Felix; Heidrich, Wolfgang

    2015-01-01

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  10. Beam shaping to provide round and square-shaped beams in optical systems of high-power lasers

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim

    2016-05-01

    Optical systems of modern high-power lasers require control of irradiance distribution: round or square-shaped flat-top or super-Gaussian irradiance profiles are optimum for amplification in MOPA lasers and for thermal load management while pumping of crystals of solid-state ultra-short pulse lasers to control heat and minimize its impact on the laser power and beam quality while maximizing overall laser efficiency, variable profiles are also important in irradiating of photocathode of Free Electron lasers (FEL). It is suggested to solve the task of irradiance re-distribution using field mapping refractive beam shapers like piShaper. The operational principle of these devices presumes transformation of laser beam intensity from Gaussian to flat-top one with high flatness of output wavefront, saving of beam consistency, providing collimated output beam of low divergence, high transmittance, extended depth of field, negligible residual wave aberration, and achromatic design provides capability to work with ultra-short pulse lasers having broad spectrum. Using the same piShaper device it is possible to realize beams with flat-top, inverse Gauss or super Gauss irradiance distribution by simple variation of input beam diameter, and the beam shape can be round or square with soft edges. This paper will describe some design basics of refractive beam shapers of the field mapping type and optical layouts of their applying in optical systems of high-power lasers. Examples of real implementations and experimental results will be presented as well.

  11. Color center lasers passively mode locked by quantum wells

    International Nuclear Information System (INIS)

    Islam, M.N.; Soccolich, C.E.; Bar-Joseph, I.; Sauer, N.; Chang, T.Y.; Miller, B.I.

    1989-01-01

    This paper describes how, using multiple quantum well (MQW) saturable absorbers, the authors passively mode locked a NaCl color center laser to produce 275 fs transform-limited, pedestal-free pulses with as high as 3.7 kW peak power. The pulses are tunable from λ = 1.59 to 1.7 μm by choosing MQW's with different bandgaps. They shortened the output pulses from the laser to 25 fs using the technique of soliton compression in a fiber. The steady-state operation of the laser requires the combination of a fast saturable absorber and gain saturation. In addition to the NaCl laser, they passively mode locked a Tl 0 (1):KCl color center laser and produced -- 22 ps pulses. Although the 275 fs pulses from the NaCl laser are Gaussian, when broadened, the pulses acquire an asymmetric spectrum because of carrier-induced refractive index changes

  12. Demystifying back scatter interferometry: a sensitive refractive index detector

    DEFF Research Database (Denmark)

    Jepsen, Søren Terpager; Jørgensen, Thomas Martini; Trydal, Torleif

    2014-01-01

    BACKGROUND: Back Scatter Interferometry (BSI) is a sensitive method for detecting changes of the refractive index (RI) in small capillaries. The method was originally developed as an off-axial column detector for use in Liquid Chromatography or Capillary Electrophoresis systems, but it has been...... acting like a common-path interferometer. METHODS: A HeNe laser is directed at a glass capillary with inner diameter of 1.4 mm and reflected light from air/glass and liquid/glass interfaces interfere to form an RI dependent intensity fringe pattern at a CCD detector. The fringe shift relative...... a common-path interferometer. The sensitivity of the BSI system is given by twice the inner diameter of the capillary times the wavenumber of the light source. Our results suggest that Back Scatter Interferometry does not provide a unique measurement principle for sensing biochemical bindings compared...

  13. Evidence for subwavelength imaging with positive refraction

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yun Gui [Temasek Laboratories, National University of Singapore, Singapore 119260 (Singapore); Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom); Ong, C K, E-mail: ulf@st-andrews.ac.uk [Centre for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, Singapore 117542 (Singapore)

    2011-03-15

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  14. Evidence for subwavelength imaging with positive refraction

    International Nuclear Information System (INIS)

    Ma, Yun Gui; Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf; Ong, C K

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  15. Modificaciones de la curvatura posterior corneal después de la cirugía refractiva láser Modifications in the corneal posterior curve after laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Lorelei Ortega Díaz

    2011-06-01

    Full Text Available OBJETIVO: Describir las modificaciones de la curvatura posterior corneal en pacientes sometidos a cirugía refractiva láser en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en el período de mayo a octubre de 2010. MÉTODOS: Se realizó un estudio descriptivo, longitudinal y prospectivo, con un universo de 257 pacientes (504 ojos sometidos a cirugía refractiva láser. La muestra quedó conformada por 31 pacientes (59 ojos. Se analizaron variables como edad, sexo, equivalente esférico, paquimetría preoperatoria, cantidad de ablación, estroma residual y diferencia de elevación posterior corneal, esta última obtenida del mapa de diferencia del topógrafo Galilei, con medición preoperatoria al mes y a los tres meses de la cirugía. Mediante análisis de regresión múltiple fueron valorados dichos cambios de la paquimetría, la cantidad de ablación y el estroma residual. RESULTADOS: El equivalente esférico, la paquimetría, la cantidad de ablación y el estroma residual se encontraron dentro de los parámetros de seguridad establecidos. La diferencia promedio de la elevación corneal posterior fue de 15,62 µm al mes y de 11,78 µm a los tres meses, con disminución significativa con el tiempo (p= 0,000. Se observó asociación con la paquimetría preoperatoria y el estroma residual, y se encontró una correlación inversa entre este último y la elevación corneal posterior a los tres meses. CONCLUSIONES: La cirugía refractiva láser induce un aumento precoz en la elevación corneal posterior, con disminución progresiva hacia el tercer mes. Los factores que más influyeron en estos cambios fueron el estroma residual y la paquimetría preoperatoria.OBJECTIVES: To describe the modifications in the corneal posterior curve in patients underwent laser refractive surgery in the "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from May to October, 2020. METHODS: A prospective, longitudinal and descriptive study was conducted

  16. Relativistic focusing and ponderomotive channeling of intense laser beams

    International Nuclear Information System (INIS)

    Hafizi, B.; Ting, A.; Sprangle, P.; Hubbard, R. F.

    2000-01-01

    The ponderomotive force associated with an intense laser beam expels electrons radially and can lead to cavitation in plasma. Relativistic effects as well as ponderomotive expulsion of electrons modify the refractive index. An envelope equation for the laser spot size is derived, using the source-dependent expansion method with Laguerre-Gaussian eigenfunctions, and reduced to quadrature. The envelope equation is valid for arbitrary laser intensity within the long pulse, quasistatic approximation and neglects instabilities. Solutions of the envelope equation are discussed in terms of an effective potential for the laser spot size. An analytical expression for the effective potential is given. For laser powers exceeding the critical power for relativistic self-focusing the analysis indicates that a significant contraction of the spot size and a corresponding increase in intensity is possible. (c) 2000 The American Physical Society

  17. Optically amplifying planar glass waveguides: Laser on a chip

    DEFF Research Database (Denmark)

    Guldberg-Kjær, Søren Andreas

    with UV-light and that permanent Bragg-gratings can be induced. Planar waveguide lasers with integrated Bragg-gratings are manufactured and characterised. It is shown that linewidths below 125 kHz and output powers around 0.5 mW can be obtained, and that the manufactured lasers are resistant to mechanical...... lightwave circuits, as well as provide the gain medium for integrated planar waveguide lasers. The work and the obtained results are presented in this thesis: The manufacturing of silica thin films is described and it is shown that the refractive index of the films can be controlled by germanium co...... as well as thermal influence. A simple method for producing an array of planar waveguide lasers is presented and it is shown that the difference in output wavelength of the individual lasers can be controlled with great accuracy....

  18. Planar waveguide amplifiers and laser in erbium doped silica

    DEFF Research Database (Denmark)

    Guldberg-Kjær, Søren Andreas; Kristensen, Martin

    1999-01-01

    with UV-light and that permanent Bragg-gratings can be induced. Planar waveguide lasers with integrated Bragg-gratings are manufactured and characterised. It is shown that linewidths below 125 kHz and output powers around 0.5 mW can be obtained, and that the manufactured lasers are resistant to mechanical...... lightwave circuits, as well as provide the gain medium for integrated planar waveguide lasers. The work and the obtained results are presented in this thesis: The manufacturing of silica thin films is described and it is shown that the refractive index o fthe films can be controlled by germanium co...... as well as thermal influence. A simple method for producing an array of planar waveguide lasers is presented and it is shown that the difference in output wavelength of the individual lasers can be controlled with great accuracy....

  19. Seismic refraction survey of the ANS preferred site

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R.K. (Automated Sciences Group, Inc., Oak Ridge, TN (United States)); Hopkins, R.A. (Marrich, Inc., Knoxville, TN (United States)); Doll, W.E. (Oak Ridge National Lab., TN (United States))

    1992-02-01

    Between September 19, 1991 and October 8, 1991 personnel from Martin Marietta Energy Systems, Inc. (Energy Systems), Automated Sciences Group, Inc., and Marrich, Inc. performed a seismic refraction survey at the Advanced Neutron Source (ANS) preferred site. The purpose of this survey was to provide estimates of top-of-rock topography, based on seismic velocities, and to delineate variations in rock and soil velocities. Forty-four seismic refraction spreads were shot to determine top-of-rock depths at 42 locations. Nine of the seismic spreads were shot with long offsets to provide 216 top-of-rock depths for 4 seismic refraction profiles. The refraction spread locations were based on the grid for the ANS Phase I drilling program. Interpretation of the seismic refraction data supports the assumption that the top-of-rock surface generally follows the local topography. The shallow top-of-rock interface interpreted from the seismic refraction data is also supported by limited drill information at the site. Some zones of anomalous data are present that could be the result of locally variable weathering, a localized variation in shale content, or depth to top-of-rock greater than the site norm.

  20. Tunable multi-wavelength polymer laser based on a triangular-lattice photonic crystal structure

    International Nuclear Information System (INIS)

    Huang, Wenbin; Pu, Donglin; Qiao, Wen; Wan, Wenqiang; Liu, Yanhua; Ye, Yan; Wu, Shaolong; Chen, Linsen

    2016-01-01

    A continuously tunable multi-wavelength polymer laser based on a triangular-lattice photonic crystal cavity is demonstrated. The triangular-lattice resonator was initially fabricated through multiple interference exposure and was then replicated into a low refractive index polymer via UV-nanoimprinting. The blend of a blue-emitting conjugated polymer and a red-emitting one was used as the gain medium. Three periods in the scalene triangular-lattice structure yield stable tri-wavelength laser emission (625.5 nm, 617.4 nm and 614.3 nm) in six different directions. A uniformly aligned liquid crystal (LC) layer was incorporated into the cavity as the top cladding layer. Upon heating, the orientation of LC molecules and thus the effective refractive index of the lasing mode changes which continuously shifts the lasing wavelength. A maximum tuning range of 12.2 nm was observed for the lasing mode at 625.5 nm. This tunable tri-wavelength polymer laser is simple constructed and cost-effective. It may find application in the fields of biosensors and photonic integrated circuits. (paper)

  1. Therapeutic results after ultrasound-guided intratissue percutaneous electrolysis (EPI®) in the treatment of rectus abdominis-related groin pain in professional footballers: a pilot study.

    Science.gov (United States)

    Moreno, Carlos; Mattiussi, Gabriele; Núñez, Francisco J

    2016-10-01

    Rectus abdominis-related groin pain (RAGP) is one of the possible clinical patterns that determine pubalgia. RAGP is one of the typical patterns in footballers and is due to the degeneration and tendinopathy of the distal tendon, at the level of the two pubic tubercles. Intratissue percutaneous electrolysis (EPI) is a novel technique used in the treatment of tendinopathies. The aim of this study was to examine the therapeutic benefits of EPI by contrasting the two basic components that characterize RAGP: painful symptoms and resultant functional deficits. Eight professional footballers at Udinese Calcio Spa Football Club underwent ultrasound-guided EPI intervention. No other type of treatment was combined with EPI. Pain was monitored with the Verbal Rating Scale, while functional deficit was monitored using the Patient Specific Functional Scale. The scales implementation took place before treatment, then 24 hours, 1 week, 1 month and 6 months after the end of treatment. Treatment with EPI produced a complete reduction of pain symptoms in one month and enabled excellent functional recovery for walking and jogging in one week; for getting out of bed, running, jumping and kicking within one month from the end of the treatment. Treatment with ultrasound-guided EPI has shown encouraging clinical results for RAGP. Data are preliminary: considering the limitations of this study more complex design studies are necessary to test the efficacy of the technique. This study introduces the EPI technique for the first time in the treatment of professional footballers suffering from RAGP. Its future use is proposed as a treatment solution, including complementary to conservative treatment.

  2. Anatase phase stability and doping concentration dependent refractivity in codoped transparent conducting TiO{sub 2} films

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T L [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan); Furubayashi, Y [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan); Hirose, Y [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan); Hitosugi, T [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan); Shimada, T [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan); Hasegawa, T [Kanagawa Academy of Science and Technology (KAST), Kawasaki 213-0012 (Japan)

    2007-10-07

    Nb{sub 0.06}Sn{sub x}Ti{sub 0.94-x}O{sub 2} (x {<=} 0.3) thin films were grown by a pulsed-laser deposition method with varying Sn concentration. Through a combinatorial technique, we find that Sn concentration can reach a maximum of about x = 0.3 while maintaining the stable anatase phase and epitaxy. A doping concentration dependence of the refractivity is revealed, in which refractivity reduction at a wavelength of {lambda} = 500 nm is estimated to be 12.4% for Nb{sub 0.06}Sn{sub 0.3} Ti{sub 0.64}O{sub 2} thin film. Sn doping induced band-gap blue shift can be contributed to the mixing of extended Sn 5s orbitals with the conduction band of TiO{sub 2}. Low resistivity on the order of 10{sup -4} {omega} cm at room temperature and high internal transmittance of more than 95% in the visible light region are exhibited for Nb{sub 0.06}Sn{sub x} Ti{sub 0.94-x}O{sub 2} thin films (x {<=} 0.2). Optical and transport analyses demonstrate that doping Sn into Nb{sub 0.06} Ti{sub 0.94}O{sub 2} can reduce the refractivity while maintaining low resistivity and high transparency.

  3. On the effective refractive index of blood

    Science.gov (United States)

    Nahmad-Rohen, Alexander; Contreras-Tello, Humberto; Morales-Luna, Gesuri; García-Valenzuela, Augusto

    2016-01-01

    We calculated the real and imaginary parts of the effective refractive index {n}{eff} of blood as functions of wavelength from 400 to 800 nm; we employed van de Hulst’s theory, together with the anomalous diffraction approximation, for the calculation. We modelled blood as a mixture of plasma and erythrocytes. Our results indicate that erythrocyte orientation has a strong effect on {n}{eff}, making blood an optically anisotropic medium except when the erythrocytes are randomly oriented. In the case in which their symmetry axis is perpendicular to the wave vector, {n}{eff} equals the refractive index of plasma at certain wavelengths. Furthermore, the erythrocytes’ shape affects their contribution to {n}{eff} in an important way, implying that studies on the effective refractive index of blood should avoid approximating them as spheres or spheroids. Finally, the effective refractive index of blood predicted by van de Hulst’s theory is different from what would be obtained by averaging the refractive indices of its constituents weighted by volume; such a volume-weighted average is appropriate only for haemolysed blood. We then measured the real part of the refractive index of various blood solutions using two different experimental setups. One of the most important results of our expriment is that {n}{eff} is measurable to a good degree of precision even for undiluted blood, although not all measuring apparatuses are appropriate. The experimental data is self-consistent and in reasonable agreement with our theoretical calculations.

  4. Method and means for a spatial and temporal probe for laser-generated plumes based on density gradients

    Science.gov (United States)

    Yeung, E.S.; Chen, G.

    1990-05-01

    A method and means are disclosed for a spatial and temporal probe for laser generated plumes based on density gradients includes generation of a plume of vaporized material from a surface by an energy source. The probe laser beam is positioned so that the plume passes through the probe laser beam. Movement of the probe laser beam caused by refraction from the density gradient of the plume is monitored. Spatial and temporal information, correlated to one another, is then derived. 15 figs.

  5. Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

    Energy Technology Data Exchange (ETDEWEB)

    Polikarpov, M., E-mail: polikarpov.maxim@mail.ru [Immanuel Kant Baltic Federal University, Nevskogo 14a, 23600 Kaliningrad (Russian Federation); Snigireva, I. [European Synchrotron Radiation Facility, 71 avenue des Martyrs, Grenoble 38043 (France); Snigirev, A. [Immanuel Kant Baltic Federal University, Nevskogo 14a, 23600 Kaliningrad (Russian Federation); European Synchrotron Radiation Facility, 71 avenue des Martyrs, Grenoble 38043 (France)

    2016-07-27

    Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

  6. Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

    International Nuclear Information System (INIS)

    Polikarpov, M.; Snigireva, I.; Snigirev, A.

    2016-01-01

    Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

  7. Light rays in gravitating, refractive media

    International Nuclear Information System (INIS)

    Noonan, T.W.

    1982-01-01

    The field-to-particle method of H. P. Robertson is applied to the general-relativistic Maxwell equations in order to obtain the general-relativistic equation of motion for a photon in a refractive medium. For the special case of an uncharged, refractive, spherically symmetric mass, the exact first-order differential equation for the light-ray path is given

  8. Femtosecond laser based small incision lenticule extraction for moderate and high myopia

    DEFF Research Database (Denmark)

    Hjortdal, Jesper Østergaard; Asp, Sven; Ivarsen, Anders

    Femtosecond laser based small incision lenticule extraction for moderate and high myopia. Jesper Hjortdal, Sven Asp, Anders Ivarsen, Anders Vestergaard Department of Ophthalmology, Aarhus University Hospital, Denmark Purpose: ReLEx® smile is a new keratorefractive procedure whereby a stromal lent....... Refractive predictability, safety and patient satisfaction at 3 months seems equal to ReLEx flex and FS-LASIK. Optimizing laser energy settings and surgeon experience is important to minimize initial inferior results....

  9. Comparison of infrared laser beam shaping by diffractive and refractive methods

    CSIR Research Space (South Africa)

    Forbes, A

    2005-08-01

    Full Text Available Infra-red laser beam shaping has the inherent difficulty that simple ray tracing methods often yield anomalous results, due primarily to the propagation effects at longer wavelengths. Techniques based on diffraction theory have been developed...

  10. Development and characterization of femtosecond laser driven soft x-ray lasers

    International Nuclear Information System (INIS)

    Bettaibi, I.

    2005-06-01

    Coherent soft x-ray sources have an important potential for scientific, medical and industrial applications. The development of high intensity laser systems allowed the realization of new coherent and fast soft x-ray sources like high order harmonic generation and soft x-ray lasers. These sources are compact, cheaper than traditional sources such as synchrotrons, and are thus interesting. This thesis presents the study of a new soft x-ray laser pumped by a femto-second laser beam working at 10 Hz. The circularly polarized ultra intense laser is longitudinally focused in a cell filled with xenon or krypton, to obtain the amplification of two lasing lines at 41.8 nm and 32.8 nm in Pd-like xenon and Ni-like krypton respectively. We carry out an experimental and numerical study of the source to understand the importance of different parameters such as the laser intensity and polarization, the gas pressure and the cell length. We have also spatially and temporally characterized the soft x-ray laser beam. To compensate the refraction of the driving laser we have investigated guiding techniques consisting in creating a plasma channel by electric discharge or using the multiple reflections of the driving laser on the internal walls of the dielectric tubes of sapphire or glass. A spectacular improvement of the source performances has been observed in both cases. Finally, we present a preliminary study on a different x-ray scheme: the inner shell photo pumping of neutral atoms. We have developed an optical system, which should create the appropriate conditions for the realisation of short wavelength x-ray amplifier. (author)

  11. Large static tuning of narrow-beam terahertz plasmonic lasers operating at 78K

    Directory of Open Access Journals (Sweden)

    Chongzhao Wu

    2017-02-01

    Full Text Available A new tuning mechanism is demonstrated for single-mode metal-clad plasmonic lasers, in which the refractive-index of the laser’s surrounding medium affects the resonant-cavity mode in the same vein as the refractive-index of gain medium inside the cavity. Reversible, continuous, and mode-hop-free tuning of ∼57 GHz is realized for single-mode narrow-beam terahertz plasmonic quantum-cascade lasers (QCLs, which is demonstrated at a much more practical temperature of 78 K. The tuning is based on post-process deposition/etching of a dielectric (silicon-dioxide on a QCL chip that has already been soldered and wire-bonded onto a copper mount. This is a considerably larger tuning range compared to previously reported results for terahertz QCLs with directional far-field radiation patterns. The key enabling mechanism for tuning is a recently developed antenna-feedback scheme for plasmonic lasers, which leads to the generation of hybrid surface-plasmon-polaritons propagating outside the cavity of the laser with a large spatial extent. The effect of dielectric deposition on QCL’s characteristics is investigated in detail including that on maximum operating temperature, peak output power, and far-field radiation patterns. Single-lobed beam with low divergence (<7° is maintained through the tuning range. The antenna-feedback scheme is ideally suited for modulation of plasmonic lasers and their sensing applications due to the sensitive dependence of spectral and radiative properties of the laser on its surrounding medium.

  12. REFRACTIVE ERROR STATUS IN BAYELSA STATE, NIGERIA

    African Journals Online (AJOL)

    LIVINGSTON

    deepening poverty because of their inability to see well” . In 2002, the .... all the refractions) and other health workers. During the period .... To the best of our knowledge, there is no ... 2020 and eliminate uncorrected refractive error within the ...

  13. Evidence for subwavelength imaging with positive refraction

    OpenAIRE

    Ma, Yun Gui; Sahebdivan, Sahar; Ong, C. K.; Tyc, Tomas; Leonhardt, Ulf

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction. Publisher PDF Peer reviewed

  14. Effect of refractive error on temperament and character properties

    Institute of Scientific and Technical Information of China (English)

    Emine; Kalkan; Akcay; Fatih; Canan; Huseyin; Simavli; Derya; Dal; Hacer; Yalniz; Nagihan; Ugurlu; Omer; Gecici; Nurullah; Cagil

    2015-01-01

    AIM: To determine the effect of refractive error on temperament and character properties using Cloninger’s psychobiological model of personality.METHODS: Using the Temperament and Character Inventory(TCI), the temperament and character profiles of 41 participants with refractive errors(17 with myopia,12 with hyperopia, and 12 with myopic astigmatism) were compared to those of 30 healthy control participants.Here, temperament comprised the traits of novelty seeking, harm-avoidance, and reward dependence, while character comprised traits of self-directedness,cooperativeness, and self-transcendence.RESULTS: Participants with refractive error showed significantly lower scores on purposefulness,cooperativeness, empathy, helpfulness, and compassion(P <0.05, P <0.01, P <0.05, P <0.05, and P <0.01,respectively).CONCLUSION: Refractive error might have a negative influence on some character traits, and different types of refractive error might have different temperament and character properties. These personality traits may be implicated in the onset and/or perpetuation of refractive errors and may be a productive focus for psychotherapy.

  15. Nonlinear optical measurements of conducting copolymers of aniline under CW laser excitation

    Science.gov (United States)

    Pramodini, S.; Poornesh, P.

    2015-08-01

    Synthesis and measurements of third-order optical nonlinearity and optical limiting of conducting copolymers of aniline are presented. Single beam z-scan technique was employed for the nonlinear optical studies. Continuous wave He-Ne laser operating at 633 nm was used as the source of excitation. Copolymer samples exhibited reverse saturable absorption (RSA) process. The nonlinear refraction studies depict that the copolymers exhibit self-defocusing property. The estimated values of βeff, n2 and χ(3) were found to be of the order of 10-2 cm/W, 10-5 esu and 10-7 esu respectively. Self-diffraction rings were observed due to refractive index change when exposed to the laser beam. A good optical limiting and clamping of power of ∼0.9 mW and ∼0.05 mW was observed. Therefore, copolymers of aniline emerge as a potential candidate for photonic device applications.

  16. Earth Model with Laser Beam Simulating Seismic Ray Paths.

    Science.gov (United States)

    Ryan, John Arthur; Handzus, Thomas Jay, Jr.

    1988-01-01

    Described is a simple device, that uses a laser beam to simulate P waves. It allows students to follow ray paths, reflections and refractions within the earth. Included is a set of exercises that lead students through the steps by which the presence of the outer and inner cores can be recognized. (Author/CW)

  17. Perfect imaging without negative refraction

    OpenAIRE

    Leonhardt, Ulf

    2009-01-01

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively-refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing ma...

  18. Laser Doppler measurements in two-phase flows

    International Nuclear Information System (INIS)

    Durst, F.; Zare, M.

    1976-01-01

    Basic theory for laser-Doppler velocity measurements of large reflecting or refracting surfaces is provided. It is shown that the Doppler-signals contain information of the velocity and size of the large bodies, and relationships for transforming velocity and radius of curvature of moving spheres are presented. Preliminary experiments verified the analytical findings and demonstrated the applicability of the method to some two-phase flows

  19. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  20. WATER SURFACE RECONSTRUCTION IN AIRBORNE LASER BATHYMETRY FROM REDUNDANT BED OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    G. Mandlburger

    2017-09-01

    Full Text Available In airborne laser bathymetry knowledge of exact water level heights is a precondition for applying run-time and refraction correction of the raw laser beam travel path in the medium water. However, due to specular reflection especially at very smooth water surfaces often no echoes from the water surface itself are recorded (drop outs. In this paper, we first discuss the feasibility of reconstructing the water surface from redundant observations of the water bottom in theory. Furthermore, we provide a first practical approach for solving this problem, suitable for static and locally planar water surfaces. It minimizes the bottom surface deviations of point clouds from individual flight strips after refraction correction. Both theoretical estimations and practical results confirm the potential of the presented method to reconstruct water level heights in dm precision. Achieving good results requires enough morphological details in the scene and that the water bottom topography is captured from different directions.

  1. Dispersion characteristics of negative refraction sonic crystals

    International Nuclear Information System (INIS)

    Wu, L.-Y.; Chen, L.-W.; Wang, R.C.-C.

    2008-01-01

    Dispersion characteristics of negative refraction sonic crystals are investigated. The plane wave expansion method is used to calculate the equifrequency surface; the dependences of refractive direction on frequencies and incident angles for triangular lattices are shown. There exist the positive and negative refractive waves which include k.V g ≥0 and k.V g ≤0 in the second band for the triangular system. We also use the finite element method to demonstrate that the relative intensity of the transmitted acoustic waves is dependent on incident frequencies and angles. The positions of the partial band gaps obtained by the plane wave expansion method are in good agreement with those obtained by the finite element method. The sonic crystals with negative effective index are shown to have higher transmission intensities. By using the negative refraction behavior, we can design a sonic crystal plane lens to focus a sonic wave

  2. Production and characterization of femtosecond laser-written double line waveguides in heavy metal oxide glasses

    Science.gov (United States)

    da Silva, Diego Silvério; Wetter, Niklaus Ursus; de Rossi, Wagner; Kassab, Luciana Reyes Pires; Samad, Ricardo Elgul

    2018-01-01

    We report the fabrication and characterization of double line waveguides directly written in tellurite and germanate glasses using a femtosecond laser delivering 30 μJ, 80 fs pulses at 4 kHz repetition rate. The double line waveguides produced presented internal losses inferior to 2.0 dB/cm. The output mode profile and the M2 measurements indicate multimodal guiding behavior. A better beam quality for the GeO2 - PbO waveguide was observed when compared with TeO2 - ZnO glass. Raman spectroscopy of the waveguides showed structural modification of the glassy network and indicates that a negative refractive index modification occurs at the focus of the laser beam, therefore allowing for light guiding in between two closely spaced laser written lines. The refractive index change at 632 nm is around 10-4, and the structural changes in the laser focal region of the writing, evaluated by Raman spectroscopy, corroborated our findings that these materials are potential candidates for optical waveguides and passive components. To the best of our knowledge, the two double line configuration demonstrated in the present work was not reported before for germanate or tellurite glasses.

  3. Electrically pumped edge-emitting photonic bandgap semiconductor laser

    Science.gov (United States)

    Lin, Shawn-Yu; Zubrzycki, Walter J.

    2004-01-06

    A highly efficient, electrically pumped edge-emitting semiconductor laser based on a one- or two-dimensional photonic bandgap (PBG) structure is described. The laser optical cavity is formed using a pair of PBG mirrors operating in the photonic band gap regime. Transverse confinement is achieved by surrounding an active semiconductor layer of high refractive index with lower-index cladding layers. The cladding layers can be electrically insulating in the passive PBG mirror and waveguide regions with a small conducting aperture for efficient channeling of the injection pump current into the active region. The active layer can comprise a quantum well structure. The quantum well structure can be relaxed in the passive regions to provide efficient extraction of laser light from the active region.

  4. Transient magnetized plasma as an optical element for high power laser pulses

    Directory of Open Access Journals (Sweden)

    Nobuhiko Nakanii

    2015-02-01

    Full Text Available Underdense plasma produced in gas jets by low intensity laser prepulses in the presence of a static magnetic field, B∼0.3  T, is shown experimentally to become an optical element allowing steering of tightly focused high power femtosecond laser pulses within several degrees along with essential enhancement of pulse’s focusability. Strong laser prepulses form a density ramp perpendicularly to magnetic field direction and, owing to the light refraction, main laser pulses propagate along the magnetic field even if it is tilted from the laser axis. Electrons generated in the laser pulse wake are well collimated and follow in the direction of the magnetic field; their characteristics are measured to be not sensitive to the tilt of magnetic field up to angles ±5°.

  5. Cryogenic refractive index of Heraeus homosil glass

    Science.gov (United States)

    Miller, Kevin H.; Quijada, Manuel A.; Leviton, Douglas B.

    2017-08-01

    This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34—3.16 μm and temperature range of 120—335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASA's Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a fieldwidened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitive performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/dλ) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in the literature.

  6. Optical polymers for laser medical applications

    Science.gov (United States)

    Sultanova, Nina G.; Kasarova, Stefka N.; Nikolov, Ivan D.

    2016-01-01

    In medicine, optical polymers are used not only in ophthalmology but in many laser surgical, diagnostic and therapeutic systems. The application in lens design is determined by their refractive and dispersive properties in the considered spectral region. We have used different measuring techniques to obtain precise refractometric data in the visible and near-infrared spectral regions. Dispersive, thermal and other important optical characteristics of polymers have been studied. Design of a plastic achromatic objective, used in a surgical stereo-microscope at 1064 nm laser wavelength, is accomplished. Geometrical and wavefront aberrations are calculated. Another example of application of polymers is the designed all-mirror apochromatic micro-lens, intended for superluminescent diode fiber coupling in medical systems.

  7. Plasmon-negative refraction at the heterointerface of graphene sheet arrays.

    Science.gov (United States)

    Huang, He; Wang, Bing; Long, Hua; Wang, Kai; Lu, Peixiang

    2014-10-15

    We demonstrate negative refraction of surface plasmon polaritons (SPPs) at the heterointerface of two monolayer graphene sheet arrays (MGSAs) with different periods. The refraction angle is specifically related to the period ratio of the two MGSAs. By varying the incident Bloch momentum, the SPPs might be refracted in the direction normal to the heterointerface. Moreover, both positive and negative refraction could appear simultaneously. Because of the linear diffraction relation, the incident and refracted SPP beams experience diffraction-free propagation. The heterostructures composed of the MGSAs may find great applications in deep-subwavelength spatial light modulators, optical splitters, and switches.

  8. Refractive index as materials property. Der Brechungsindex als Stoffeigenschaft

    Energy Technology Data Exchange (ETDEWEB)

    Zilian, U. (Ciba-Geigy AG, Basel (Switzerland))

    1991-10-01

    The investigation of the relationship between refractive index (n) and molecular structure of a series of gases, liquids, and solids led to the conclusion that the refractive index of a substance is an independent molecular property. Light is refracted by two types of electron pairs. a) Bonding Electron Pairs (BEP) and b) Response Electron Pairs (REP). - Paraffins exhibit only BEPs which can easily be counted. REP is a new term we introduce to quantify the effects of several nonbonding electrons. The inert gases, for example, refract solely with REPs. They can be determined, and the most important ones are herein tabulated or delineated in the text. For compounds with known formular weight (M) and density (d), the refractive index can be simply calculated using the following formula. (orig.).

  9. UV waveguides light fabricated in fluoropolymer CYTOP by femtosecond laser direct writing.

    Science.gov (United States)

    Hanada, Yasutaka; Sugioka, Koji; Midorikawa, Katsumi

    2010-01-18

    We have fabricated optical waveguides inside the UV-transparent polymer, CYTOP, by femtosecond laser direct writing for propagating UV light in biochip applications. Femtosecond laser irradiation is estimated to increase the refractive index of CYTOP by 1.7 x 10(-3) due to partial bond breaking in CYTOP. The waveguide in CYTOP has propagation losses of 0.49, 0.77, and 0.91 dB/cm at wavelengths of 632.8, 355, and 266 nm, respectively.

  10. Pump-induced refractive index changes in Tb{sup 3+} doped glasses

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, T.A.; Santos, J.F.M. dos; Auad, Y.M; Nunes, L.A.O. [Instituto de Física de São Carlos, Universidade de São Paulo, SP (Brazil); Astrath, N.G.C; Baesso, M.L. [Departamento de Física, Universidade Estadual de Maringá, PR (Brazil); Catunda, T., E-mail: tomaz@ifsc.usp.br [Instituto de Física de São Carlos, Universidade de São Paulo, SP (Brazil)

    2016-01-15

    It now well known in laser materials, that a refractive index change appears when the active ions are pumped from ground to excited state due to the polarizability difference between ground and excited states (metastable). In this paper this effect was investigated in Tb{sup 3+} doped glasses: calcium alumino phosphate (CAP), low-silica calcium aluminosilicate (LSCAS) and calcium aluminosilicate (CAS). The measurements were performed using the time resolved Z-scan technique, with an Ar{sup +} laser at 488 nm, close to the resonance of {sup 7}F{sub 6}→{sup 5}D{sub 4} absorption line, where {sup 5}D{sub 4} is a metastable state. We obtained for low-silica calcium aluminosilicate glass Δα{sub p}~10{sup −24} cm{sup 3} which is the highest value ever reported for a RE doped material. - Highlights: • Time resolved Z-scan measurements in 3 different Tb{sup 3+} doped glass. • Very high polarizability difference (Δα{sub p}), typically 1 order of magnitude higher than other rare earth ions. • Observations of higher order nonlinearities, such as-third, fifth and senventh order effects.

  11. Measurements of photoinduced refractive index changes in ...

    Indian Academy of Sciences (India)

    Abstract. We report the pump–probe measurements of nonlinear refractive index changes in photochromic bacteriorhodopsin films. The photoinduced absorption is caused by pump beam at 532 nm and the accompanying refractive index changes are studied using a probe beam at 633 nm. The proposed technique is ...

  12. Refractive index inversion based on Mueller matrix method

    Science.gov (United States)

    Fan, Huaxi; Wu, Wenyuan; Huang, Yanhua; Li, Zhaozhao

    2016-03-01

    Based on Stokes vector and Jones vector, the correlation between Mueller matrix elements and refractive index was studied with the result simplified, and through Mueller matrix way, the expression of refractive index inversion was deduced. The Mueller matrix elements, under different incident angle, are simulated through the expression of specular reflection so as to analyze the influence of the angle of incidence and refractive index on it, which is verified through the measure of the Mueller matrix elements of polished metal surface. Research shows that, under the condition of specular reflection, the result of Mueller matrix inversion is consistent with the experiment and can be used as an index of refraction of inversion method, and it provides a new way for target detection and recognition technology.

  13. Laser Interferometric Measurements of the Physical Properties for He, ne Gases and Their Mixture

    Science.gov (United States)

    Abdel-Moniem, N. M.; El-Masry, M. M.; El-Bradie, B.; El-Mekawy, F. M.

    2010-04-01

    A Mach-Zehner interferometer MZI illuminated with He-Ne Laser 632.8nm is used for measuring the refractive index for He, Ne gases and their mixture HeNe. The measurements are carried out at different pressures and temperatures. The error factors of the refractive index measurements for He, Ne and HeNe gases are equal to ±1.7×10-5, ±9.5×10-6 and ±7.25×10-5 respectively. Some calculations of the electrical properties are carried out such as the optical permittivity dielectric susceptibility and specific refractivity from the determination of the refractive index. Also, the molecular radii of the gases under investigation are computed then the transport coefficients (diffusion. viscosity and thermal conductivity) are calculated. All of these calculations are carried out at different pressures and temperatures. The experimental results of refractive index for the above mixture are compared with the results estimated using one of the mixing rules and a good agreement is achieved. Also, some physical parameters are compared with other values in another literatures.

  14. Exploring Broad Area Quantum Cascade Lasers

    Science.gov (United States)

    2017-10-01

    Strong current spreading: Trenches etched deeper than the active region. Minimal current spreading: Laser cavity defined by the electrical contact ...refractive index Θ: the angle measured within the cavity. x θ High-Order Transverse Modes 7 Approved for public release. Distribution is...through image. 10 Approved for public release. Distribution is unlimited. 0 5 10 15 20 25 30 -50-40-30-20-10 0 10 20 30 40 50 Angle (degrees) De vic e

  15. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    Science.gov (United States)

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  16. Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia.

    NARCIS (Netherlands)

    Nuijts, R.M.; Nabar, V.A.; Hament, W.J.; Eggink, F.A.G.J.

    2002-01-01

    To evaluate the 6-month refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb).Department of Ophthalmology, University Hospital Maastricht, Maastricht, The Netherlands.In a prospective randomized study,

  17. Influence of changes in an eye's optical system on refraction

    Science.gov (United States)

    Bartkowska, Janina

    1998-10-01

    The optical system of eye is composed of cornea, lens, anterior chamber, and vitreous body. In the standard schematic eye there are 6 refracting surfaces. The changes of the curvature radii, of the distances between them, of the refractive indices influence the ametropia, refractive power of the eye and retinal image size. The influence of these changes can be appreciated by ray tracing or by an analytical method. There are presented simplified formulae for the differentials of ametropia and refractive power of the eye with respect to the surfaces curvatures, refracting power of cornea and lens, refractive indices. The relations are valid too for bigger changes if ametropia is measured in the cornea vertex. The formulae for the differentials with respect to distances, lens translation, eye axis length are valid if ametropia is measured in the object focus of the eye.

  18. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    Science.gov (United States)

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  19. Conical Refraction: new observations and a dual cone model.

    Science.gov (United States)

    Sokolovskii, G S; Carnegie, D J; Kalkandjiev, T K; Rafailov, E U

    2013-05-06

    We propose a paraxial dual-cone model of conical refraction involving the interference of two cones of light behind the exit face of the crystal. The supporting experiment is based on beam selecting elements breaking down the conically refracted beam into two separate hollow cones which are symmetrical with one another. The shape of these cones of light is a product of a 'competition' between the divergence caused by the conical refraction and the convergence due to the focusing by the lens. The developed mathematical description of the conical refraction demonstrates an excellent agreement with experiment.

  20. Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors

    CERN Document Server

    Filippas-Tassos, A; Fokitis, E; Maltezos, S; Patrinos, K

    2002-01-01

    With an updated, flexible, highly efficient and easily installed system we obtained accurate refractivity (n-1) values. This system is a refractometer based on a Fabry-Perot interferometer and was used to monitor the refractivity of DELPHI RICH Cherenkov radiators near the VUV region. By using a Pt-Ne spectral lamp and improved alignment and temperature control, the refractivities of C//5F//1//2 and C//4F//1 //0 have been monitored since 1996. With this light source, selected to have large coherence lengths, we can extract the refractivity at several wavelengths from one data set only. The estimated errors of the refractivity measurements are less than 1.2%, and depend on wavelength and the type of gas used. The various parameters affecting the accuracy of the refractometer are also discussed. Finally, results from special sample refractivity measurements of the liquid radiator (C//6F//1//4) in its gas phase, are presented.

  1. DESIGN OF WIRE-WRAPPED ROD BUNDLE MATCHED INDEX-OF-REFRACTION EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Hugh McIlroy; Hongbin Zhang; Kurt Hamman

    2008-05-01

    Experiments will be conducted in the Idaho National Laboratory (INL) Matched Index-of-Refraction (MIR) Flow Facility [1] to characterize the three-dimensional velocity and turbulence fields in a wire-wrapped rod bundle typically employed in liquid-metal cooled fast reactors and to provide benchmark data for computer code validation. Sodium cooled fast reactors are under consideration for use in the U.S. Department of Energy (DOE) Global Nuclear Energy Partnership (GNEP) program. The experiment model will be constructed of quartz components and the working fluid will be mineral oil. Accurate temperature control (to within 0.05 oC) matches the index-of-refraction of mineral oil with that of quartz and renders the model transparent to the wavelength of laser light employed for optical measurements. The model will be a scaled 7-pin rod bundle enclosed in a hexagonal canister. Flow field measurements will be obtained with a LaVision 3-D particle image velocimeter (PIV) and complimented by near-wall velocity measurements obtained from a 2-D laser Doppler velocimeter (LDV). These measurements will be used as benchmark data for computational fluid dynamics (CFD) validation. The rod bundle model dimensions will be scaled up from the typical dimensions of a fast reactor fuel assembly to provide the maximum Reynolds number achievable in the MIR flow loop. A range of flows from laminar to fully-turbulent will be available with a maximum Reynolds number, based on bundle hydraulic diameter, of approximately 22,000. The fuel pins will be simulated by 85 mm diameter quartz tubes (closed on the inlet ends) and the wire-wrap will be simulated by 25 mm diameter quartz rods. The canister walls will be constructed from quartz plates. The model will be approximately 2.13 m in length. Bundle pressure losses will also be measured and the data recorded for code comparisons. The experiment design and preliminary CFD calculations, which will be used to provide qualitative hydrodynamic

  2. Vertical-cavity surface-emitting laser vapor sensor using swelling polymer reflection modulation

    DEFF Research Database (Denmark)

    Ansbæk, Thor; Nielsen, Claus Højgård; Dohn, Søren

    2012-01-01

    Vapor detection using a low-refractive index polymer for reflection modulation of the top mirror in a vertical-cavity surface-emitting laser (VCSEL) is demonstrated. The VCSEL sensor concept presents a simple method to detect the response of a sensor polymer in the presence of volatile organic...

  3. X-ray laser interferometry: A new tool for AGEX

    International Nuclear Information System (INIS)

    Wan, A.S.; Moreno, J.C.; Libby, S.B.

    1995-10-01

    Collisionally pumped soft x-ray lasers now operate over a wavelength range extending from 4--40 nm. With the recent advances in the development of multilayer mirrors and beamsplitters in the soft x-ray regime, we can utilize the unique properties of x-ray lasers to study large, rapidly evolving laser-driven plasmas with high electron densities. By employing a shorter wavelength x-ray laser, as compared to using conventional optical laser as the probe source, we can access a much higher density regime while reducing refractive effects which limit the spatial resolution and data interpretation. Using a neon-like yttrium x-ray laser which operates at a wavelength of 15.5 mn, we have performed a series of soft x-ray laser interferometry experiments, operated in the skewed Mach-Zehnder configuration, to characterize plasmas relevant to both weapons and inertial confinement fusion. The two-dimensional density profiles obtained from the interferograms allow us to validate and benchmark our numerical models used to study the physics in the high-energy density regime, relevant to both weapons and inertial confinement fusion

  4. Thermal conductivity contrast measurement of Fused Silica exposed to low-energy femtosecond laser pulses

    NARCIS (Netherlands)

    Bellouard, Y.J.; Dugan, M.; Said, A.A.; Bado, P.

    2006-01-01

    Femtosecond laser irradiation has various noticeable effects on fused silica. Of particular interest, pulses with energy levels below the ablation threshold can locally increase the refractive index and the material etching selectivity to hydrofluoric acid. The mechanism responsible for these

  5. Fermat's principle and the formal equivalence of local light-ray rotation and refraction at the interface between homogeneous media with a complex refractive index ratio.

    Science.gov (United States)

    Sundar, Bhuvanesh; Hamilton, Alasdair C; Courtial, Johannes

    2009-02-01

    We derive a formal description of local light-ray rotation in terms of complex refractive indices. We show that Fermat's principle holds, and we derive an extended Snell's law. The change in the angle of a light ray with respect to the normal of a refractive index interface is described by the modulus of the refractive index ratio; the rotation around the interface normal is described by the argument of the refractive index ratio.

  6. Resident and young physician experience with complex cataract surgery and new cataract and refractive technology: Results of the ASCRS 2016 Young Eye Surgeons survey.

    Science.gov (United States)

    Schallhorn, Julie M; Ciralsky, Jessica B; Yeu, Elizabeth

    2017-05-01

    A survey was offered to attendees of the 2016 annual meeting of the American Society of Cataract and Refractive Surgery (ASCRS) as well as online to ASCRS members. Of the 429 self-identified surgeons in training or those with fewer than 5 years in practice, 83% had performed complex cataract surgery using iris expansion devices or capsular tension rings (63%) and 70% had implanted a toric intraocular lens (IOL). A minority of respondents had performed laser-assisted cataract surgery (27%) or implanted presbyopia-correcting IOLs (39%), and only half (50%) had performed laser vision correction (LVC). Comfort with complex cataract and IOL procedures improved with increasing number of cases performed until greater than 10 cases. From this we can conclude that young surgeons have adequate exposure to complex cataracts but lack experience in refractive surgery and new IOL technology. Reported surgeon confidence improved with increased experience and exposure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Topography-modified refraction: adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    OpenAIRE

    Alpins, Noel

    2017-01-01

    Noel Alpins1,2 1NewVision Clinics, Melbourne, VIC, Australia; 2Department Ophthalmology, Melbourne University, Melbourne, VIC, Australia It is encouraging to see the results in the article by Kanellopoulos “Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK”,1 where the combination of refractive and corneal data in the treatment parameters pro...

  8. Prepulse effect on intense femtosecond laser pulse propagation in gas

    International Nuclear Information System (INIS)

    Giulietti, Antonio; Tomassini, Paolo; Galimberti, Marco; Giulietti, Danilo; Gizzi, Leonida A.; Koester, Petra; Labate, Luca; Ceccotti, Tiberio; D'Oliveira, Pascal; Auguste, Thierry; Monot, Pascal; Martin, Philippe

    2006-01-01

    The propagation of an ultrashort laser pulse can be affected by the light reaching the medium before the pulse. This can cause a serious drawback to possible applications. The propagation in He of an intense 60-fs pulse delivered by a Ti:sapphire laser in the chirped pulse amplification (CPA) mode has been investigated in conditions of interest for laser-plasma acceleration of electrons. The effects of both nanosecond amplified spontaneous emission and picosecond pedestals have been clearly identified. There is evidence that such effects are basically of refractive nature and that they are not detrimental for the propagation of a CPA pulse focused to moderately relativistic intensity. The observations are fully consistent with numerical simulations and can contribute to the search of a stable regime for laser acceleration

  9. Scattering of light passing through a statistically rough interface between media with different refractive indices after laser correction of vision

    Energy Technology Data Exchange (ETDEWEB)

    Semchishen, A V; Seminogov, V N; Semchishen, V A [Institute of Laser and Information Technologies, Russian Academy of Sciences, Troitsk, Moscow Region (Russian Federation)

    2012-04-30

    Forward scattering of light passing through large-scale irregularities of the interface between two media having different refractive indices is considered. An analytical expression for the ratio of intensities of directional and diffusion components of scattered light in the far-field zone is derived. It is theoretically shown that the critical depth of possible interface relief irregularities, starting from which the intensity of the diffuse component in the passing light flow becomes comparable with the directional light component, responsible for the image formation on the eye retina, is 3 - 4 {mu}m, with the increase in the refractive index in the postoperational zone taken into account. These profile depth values agree with the experimentally measured ones and may affect the contrast sensitivity of vision.

  10. Scattering of light passing through a statistically rough interface between media with different refractive indices after laser correction of vision

    International Nuclear Information System (INIS)

    Semchishen, A V; Seminogov, V N; Semchishen, V A

    2012-01-01

    Forward scattering of light passing through large-scale irregularities of the interface between two media having different refractive indices is considered. An analytical expression for the ratio of intensities of directional and diffusion components of scattered light in the far-field zone is derived. It is theoretically shown that the critical depth of possible interface relief irregularities, starting from which the intensity of the diffuse component in the passing light flow becomes comparable with the directional light component, responsible for the image formation on the eye retina, is 3 - 4 μm, with the increase in the refractive index in the postoperational zone taken into account. These profile depth values agree with the experimentally measured ones and may affect the contrast sensitivity of vision.

  11. Scalable, large area compound array refractive lens for hard X-rays

    Science.gov (United States)

    Reich, Stefan; dos Santos Rolo, Tomy; Letzel, Alexander; Baumbach, Tilo; Plech, Anton

    2018-04-01

    We demonstrate the fabrication of a 2D Compound Array Refractive Lens (CARL) for multi-contrast X-ray imaging. The CARL consists of six stacked polyimide foils with each displaying a 2D array of lenses with a 65 μm pitch aiming for a sensitivity on sub-micrometer structures with a (few-)micrometer resolution in sensing through phase and scattering contrast at multiple keV. The parabolic lenses are formed by indents in the foils by a paraboloid needle. The ability for fast single-exposure multi-contrast imaging is demonstrated by filming the kinetics of pulsed laser ablation in liquid. The three contrast channels, absorption, differential phase, and scattering, are imaged with a time resolution of 25 μs. By changing the sample-detector distance, it is possible to distinguish between nanoparticles and microbubbles.

  12. Refractive index and temperature sensitivity characteristics of a micro-slot fiber Bragg grating.

    Science.gov (United States)

    Saffari, Pouneh; Yan, Zhijun; Zhou, Kaiming; Zhang, Lin

    2012-07-10

    Fabrication and characterization of a UV inscribed fiber Bragg grating (FBG) with a micro-slot liquid core is presented. Femtosecond (fs) laser patterning/chemical etching technique was employed to engrave a micro-slot with dimensions of 5.74 μm(h)×125 μm(w)×1388.72 μm(l) across the whole grating. The device has been evaluated for refractive index (RI) and temperature sensitivities and exhibited distinctive thermal response and RI sensitivity beyond the detection limit of reported fiber gratings. This structure has not just been RI sensitive, but also maintained the robustness comparing with the bare core FBGs and long-period gratings with the partial cladding etched off.

  13. Transverse and temporal characteristics of a high-gain free-electron laser in the saturation regime

    CERN Document Server

    Huang Zhi Rong

    2002-01-01

    The transverse and the temporal characteristics of a high-gain free-electron laser are governed by refractive guiding and sideband instability, respectively. Using the self-consistent Vlasov-Maxwell equations, we explicitly determine the effective index of refraction and the guided radiation mode for an electron beam with arbitrary transverse size. Electrons trapped by the guided radiation execute synchrotron oscillation and hence are susceptible to the sideband instability. We explain the spectral evolution and determine the sideband growth rate. These theoretical predictions agree well with GINGER simulation results.

  14. Ultra-weak FBG and its refractive index distribution in the drawing optical fiber.

    Science.gov (United States)

    Guo, Huiyong; Liu, Fang; Yuan, Yinquan; Yu, Haihu; Yang, Minghong

    2015-02-23

    For the online writing of ultra-weak fiber Bragg gratings (FBGs) in the drawing optical fibers, the effects of the intensity profile, pulse fluctuation and pulse width of the excimer laser, as well as the transverse and longitudinal vibrations of the optical fiber have been investigated. Firstly, using Lorentz-Loren equation, Gladstone-Dale mixing rule and continuity equation, we have derived the refractive index (RI) fluctuation along the optical fiber and the RI distribution in the FBG, they are linear with the gradient of longitudinal vibration velocity. Then, we have prepared huge amounts of ultra-weak FBGs in the non-moving optical fiber and obtained their reflection spectra, the measured reflection spectra shows that the intensity profile and pulse fluctuation of the excimer laser, as well as the transverse vibration of the optical fiber are little responsible for the inconsistency of ultra-weak FBGs. Finally, the effect of the longitudinal vibration of the optical fiber on the inconsistency of ultra-weak FBGs has been discussed, and the vibration equations of the drawing optical fiber are given in the appendix.

  15. Closure phenomena in pinholes irradiated by Nd laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, J.M.; Holmes, N.C.; Hunt, J.T.; Linford, G.J.

    1979-07-15

    An experimental investigation has been made on plasma closure in pinholes irradiated by Nd glass laser pulses; 300--500-..mu..m diam pinholes of various materials and thicknesses have been irradiated by 20--100-J 300-psec FWHM pulses on the Janus laser system. Calorimetry measurements have yielded data on pinhole energy transmission and intensity loading on the periphery of the pinhole. Ultrafast streak photography measurements indicate effective closure velocities of 2--5 x 10/sup 7/ cm/sec. Scattered light measurements have shown the transmission loss through a typical spatial filter configuration to be primarily refractive in nature.

  16. Development of a nomogram for femtosecond laser astigmatic keratotomy for astigmatism after keratoplasty.

    Science.gov (United States)

    St Clair, Ryan M; Sharma, Anushree; Huang, David; Yu, Fei; Goldich, Yakov; Rootman, David; Yoo, Sonia; Cabot, Florence; Jun, Jason; Zhang, Lijun; Aldave, Anthony J

    2016-04-01

    To develop a nomogram for femtosecond laser astigmatic keratotomy (AK) to treat post-keratoplasty astigmatism. Three academic medical centers. Retrospective interventional case series. A review of post-keratoplasty femtosecond laser AK was performed. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and keratometry were recorded preoperatively and 1, 3, 6, and 12 months postoperatively. The location, length, depth, and diameter of the AK incisions were recorded, and the surgically induced astigmatic correction was related to these variables using regression analysis. One hundred forty femtosecond laser AK procedures were performed after penetrating keratoplasty (PKP) (n = 129) or deep anterior lamellar keratoplasty (DALK) (n =11), with 89 procedures (80 PKP, 9 DALK) included in the analysis. The mean CDVA improved from 20/59 (0.47 logMAR ± 0.38 [SD]) preoperatively to 20/45 (0.35 ± 0.31 logMAR) postoperatively (P = .013) (n = 46). The mean keratometric astigmatism decreased from 8.26 ± 2.90 diopters (D) preoperatively to 3.62 ± 2.59 D postoperatively (P AK to treat post-keratoplasty astigmatism was generated using regression analysis. Femtosecond laser AK significantly improved UDVA and CDVA and significantly reduced keratometric astigmatism and refractive cylinder after keratoplasty. The nomogram generated should improve the accuracy of post-keratoplasty femtosecond laser AK. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Optical negative refraction by four-wave mixing in thin metallic nanostructures.

    Science.gov (United States)

    Palomba, Stefano; Zhang, Shuang; Park, Yongshik; Bartal, Guy; Yin, Xiaobo; Zhang, Xiang

    2011-10-30

    The law of refraction first derived by Snellius and later introduced as the Huygens-Fermat principle, states that the incidence and refracted angles of a light wave at the interface of two different materials are related to the ratio of the refractive indices in each medium. Whereas all natural materials have a positive refractive index and therefore exhibit refraction in the positive direction, artificially engineered negative index metamaterials have been shown capable of bending light waves negatively. Such a negative refractive index is the key to achieving a perfect lens that is capable of imaging well below the diffraction limit. However, negative index metamaterials are typically lossy, narrow band, and require complicated fabrication processes. Recently, an alternative approach to obtain negative refraction from a very thin nonlinear film has been proposed and experimentally demonstrated in the microwave region. However, such approaches use phase conjugation, which makes optical implementations difficult. Here, we report a simple but different scheme to demonstrate experimentally nonlinear negative refraction at optical frequencies using four-wave mixing in nanostructured metal films. The refractive index can be designed at will by simply tuning the wavelengths of the interacting waves, which could have potential impact on many important applications, such as superlens imaging.

  18. Development of improved laser glasses which can be melted on a commercial scale. Annual progress report, September 15, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, C.F.; Huff, N.T.; Vergano, P.J.

    1978-04-01

    Large neodymium doped glass laser systems are presently being built for nuclear fusion research. However, the power which can be generated by these systems is generally limited by self focusing in the laser glass. This study was undertaken to develop laser glasses with a minimum nonlinear refractive index which would allow the generation of higher powers in these laser systems. Various fluorophosphate glass forming systems were investigated in order to develop laser glasses with ''optimum'' properties (low n/sub 2/, medium sigma, long tau, highly stable). In these fluorophosphate systems, the regions of glass formation were defined and glass composition-property correlation equations were derived which related the various properties (n/sub D/, n/sub 2/, sigma, the Nd/sup 3 +/ peak lambda, ..delta..lambda, effective ..delta..lambda, sigma and tau radiative) to the glass composition. Specific glass compositions were developed which had nonlinear refractive indices of about /sup 1///sub 3/ those of commercial silicate laser glasses but had comparable spectroscopic properties (i.e., sigma). These glasses were sufficiently stable to cast single pieces of glass weighing in excess of 50 lbs.

  19. [Incidence of refractive errors with corrective aids subsequent selection].

    Science.gov (United States)

    Benes, P; Synek, S; Petrová, S; Sokolová, Sidlová J; Forýtková, L; Holoubková, Z

    2012-02-01

    This study follows the occurrence of refractive errors in population and the possible selection of the appropriate type of corrective aids. Objective measurement and subsequent determination of the subjective refraction of the eye is on essential act in opotmetric practice. The file represented by 615 patients (1230 eyes) is divided according to the refractive error of myopia, hyperopia and as a control group are listed emetropic clients. The results of objective and subjective values of refraction are compared and statistically processed. The study included 615 respondents. To determine the objective refraction the autorefraktokeratometer with Placido disc was used and the values of spherical and astigmatic correction components, including the axis were recorded. These measurements were subsequently verified and tested subjectively using the trial lenses and the projection optotype to the normal investigative distance of 5 meters. After this the appropriate corrective aids were then recommended. Group I consists of 123 men and 195 women with myopia (n = 635) of clients with an average age 39 +/- 18,9 years. Objective refraction - sphere: -2,57 +/- 2,46 D, cylinder: -1,1 +/- 1,01 D, axis of: 100 degrees +/- 53,16 degrees. Subjective results are as follows--the value of sphere: -2,28 +/- 2,33 D, cylinder -0,63 +/- 0,80 D, axis of: 99,8 degrees +/- 56,64 degrees. Group II is represented hyperopic clients and consists of 67 men and 107 women (n = 348). The average age is 58,84 +/- 16,73 years. Objective refraction has values - sphere: +2,81 +/- 2,21 D, cylinder: -1,0 +/- 0,94 D; axis 95 degree +/- 45,4 degrees. Subsequent determination of subjective refraction has the following results - sphere: +2,28 +/- 2,06 D; cylinder: -0,49 +/- 0,85 D, axis of: 95,9 degrees +/- 46,4 degrees. Group III consists from emetropes whose final minimum viasual acuity was Vmin = 1,0 (5/5) or better. Overall, this control group is represented 52 males and 71 females (n = 247). The average

  20. Acoustic metasurface for refracted wave manipulation

    Science.gov (United States)

    Han, Li-Xiang; Yao, Yuan-Wei; Zhang, Xin; Wu, Fu-Gen; Dong, Hua-Feng; Mu, Zhong-Fei; Li, Jing-bo

    2018-02-01

    Here we present a design of a transmitted acoustic metasurface based on a single row of Helmholtz resonators with varying geometric parameters. The proposed metasurface can not only steer an acoustic beam as expected from the generalized Snell's law of refraction, but also exhibits various interesting properties and potential applications such as insulation of two quasi-intersecting transmitted sound waves, ultrasonic Bessel beam generator, frequency broadening effect of anomalous refraction and focusing.

  1. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Unstable Resonator Mid-Infrared Laser Sources

    Science.gov (United States)

    2016-02-26

    effective refractive indices of the guided mode at the grating ridge and groove were calcu- lated using a 4-layer slab waveguide model with a top clad... waterfall plot of the spectra. This DFB laser device demonstrated a continuous, mode-hop-free, tuning range of 80 nm, from 3057 to 3137 nm at ~2.5...curve is a quadratic fit. The inset shows the grating normal pump configuration (GNC). (b) Waterfall plot of the individual spectra vs. pump position

  3. High temperature refractive indices of GaN

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C.; Stepanov, S.; Gott, A.; Shields, P.A.; Zhirnov, E.; Wang, W.N. [Department of Physics, University of Bath, Bath, BA2 7AY (United Kingdom); Steimetz, E.; Zettler, J.T. [LayTec, Helmholtzstr. 13-14, 10587 Berlin (Germany)

    2006-06-15

    Undoped GaN (u-GaN) films were grown by low pressure metalorganic vapour phase epitaxy (LP-MOVPE) on sapphire substrates. In situ optical monitoring was applied to the growth process either using a LayTec EpiR-DA TT spectroscopic reflectometer or Filmetrics F30. Refractive indices of u-GaN films at 1060 C were obtained in a spectral range from 370-900 nm. A peak at 412{+-}5 nm in refractive index spectra was observed, which most likely corresponds to the band-gap of hexagonal GaN at a temperature of 1060 C. Refractive indices below this band-gap are fitted well to the first-order Sellmeier formula. As an example of the applications of the refractive indices, the effective film thicknesses of GaN during the resumption from 3 dimensional (3D) to 2 dimensional (2D) growth have been calculated from the spectra recorded by a LayTec system using the optical constants obtained. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  5. Making the invisible visible: a microfluidic chip using a low refractive index polymer.

    Science.gov (United States)

    Hanada, Yasutaka; Ogawa, Tatsuya; Koike, Kazuhiko; Sugioka, Koji

    2016-07-07

    Microfluidic frameworks known as micro-total-analysis-systems or lab-on-a-chip have become versatile tools in cell biology research, since functional biochips are able to streamline dynamic observations of various cells. Glass or polymers are generally used as the substrate due to their high transparency, chemical stability and cost-effectiveness. However, these materials are not well suited for the microscopic observation of cell migration at the fluid boundary due to the refractive index mismatch between the medium and the biochip material. For this reason, we have developed a new method of fabricating three-dimensional (3D) microfluidic chips made of the low refractive index fluoric polymer CYTOP. This novel fabrication procedure involves the use of a femtosecond laser for direct writing, followed by wet etching with a dilute fluorinated solvent and annealing, to create high-quality 3D microfluidic chips inside a polymer substrate. A microfluidic chip made in this manner enabled us to more clearly observe the flagellum motion of a Dinoflagellate moving in circles near the fluid surface compared to the observations possible using conventional microfluidic chips. We believe that CYTOP microfluidic chips made using this new method may allow more detailed analysis of various cell migrations near solid boundaries.

  6. Black and gray Helmholtz-Kerr soliton refraction

    International Nuclear Information System (INIS)

    Sanchez-Curto, Julio; Chamorro-Posada, Pedro; McDonald, Graham S.

    2011-01-01

    Refraction of black and gray solitons at boundaries separating different defocusing Kerr media is analyzed within a Helmholtz framework. A universal nonlinear Snell's law is derived that describes gray soliton refraction, in addition to capturing the behavior of bright and black Kerr solitons at interfaces. Key regimes, defined by beam and interface characteristics, are identified, and predictions are verified by full numerical simulations. The existence of a unique total nonrefraction angle for gray solitons is reported; both internal and external refraction at a single interface is shown possible (dependent only on incidence angle). This, in turn, leads to the proposal of positive or negative lensing operations on soliton arrays at planar boundaries.

  7. THE OPTICS OF REFRACTIVE SUBSTRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Michael D.; Narayan, Ramesh, E-mail: mjohnson@cfa.harvard.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2016-08-01

    Newly recognized effects of refractive scattering in the ionized interstellar medium have broad implications for very long baseline interferometry (VLBI) at extreme angular resolutions. Building upon work by Blandford and Narayan, we present a simplified, geometrical optics framework, which enables rapid, semi-analytic estimates of refractive scattering effects. We show that these estimates exactly reproduce previous results based on a more rigorous statistical formulation. We then derive new expressions for the scattering-induced fluctuations of VLBI observables such as closure phase, and we demonstrate how to calculate the fluctuations for arbitrary quantities of interest using a Monte Carlo technique.

  8. An improved prism for use in laser resonators

    Science.gov (United States)

    Richards, J.

    1981-08-01

    The use of compound total internal reflection prisms rather than Porro prisms in polarisation coupled lasers is proposed. Performance advantages resulting from the use of these prisms include higher output without the need to bias the Pockels cell, ability to give a larger range of output coupling and independence of performance on the refractive index of the prism. In conventional Q-switched lasers the use of the prism at the Pockels cell end of the resonator instead of the usual 100% reflecting mirror also leads to some advantages including better hold-off, elimination of the need to bias the Pockels cell and insensitivity in one plane to angular misalignment.

  9. Analytical models of optical refraction in the troposphere.

    Science.gov (United States)

    Nener, Brett D; Fowkes, Neville; Borredon, Laurent

    2003-05-01

    An extremely accurate but simple asymptotic description (with known error) is obtained for the path of a ray propagating over a curved Earth with radial variations in refractive index. The result is sufficiently simple that analytic solutions for the path can be obtained for linear and quadratic index profiles. As well as rendering the inverse problem trivial for these profiles, this formulation shows that images are uniformly magnified in the vertical direction when viewed through a quadratic refractive-index profile. Nonuniform vertical distortions occur for higher-order refractive-index profiles.

  10. Ultraviolet light induced refractive index structures in germanosilica

    DEFF Research Database (Denmark)

    Svalgaard, Mikael

    1997-01-01

    The focus of the research presented in this ph.d. thesis is refractive index structures photoinduced in germanonsilica waveguides with ultra-violet (UV) radiation. The physical mechanisms involved in photosensitivity and applications of a wide range of UV induced refractive index structures in both...... application of a scanning near-field optical microscope to obtain high resolution images of UV induced refractive index structures and by monitoring the dynamics of UV induced index changes and luminescence. During part of my ph.d. project I have worked at the National Institute of Standards and Technolgy...

  11. Wavefront-guided versus wavefront-optimized laser in situ keratomileusis: contralateral comparative study.

    Science.gov (United States)

    Padmanabhan, Prema; Mrochen, Michael; Basuthkar, Subam; Viswanathan, Deepa; Joseph, Roy

    2008-03-01

    To compare the outcomes of wavefront-guided and wavefront-optimized treatment in fellow eyes of patients having laser in situ keratomileusis (LASIK) for myopia. Medical and Vision Research Foundation, Tamil Nadu, India. This prospective comparative study comprised 27 patients who had wavefront-guided LASIK in 1 eye and wavefront-optimized LASIK in the fellow eye. The Hansatome (Bausch & Lomb) was used to create a superior-hinged flap and the Allegretto laser (WaveLight Laser Technologie AG), for photoablation. The Allegretto wave analyzer was used to measure ocular wavefront aberrations and the Functional Acuity Contrast Test chart, to measure contrast sensitivity before and 1 month after LASIK. The refractive and visual outcomes and the changes in aberrations and contrast sensitivity were compared between the 2 treatment modalities. One month postoperatively, 92% of eyes in the wavefront-guided group and 85% in the wavefront-optimized group had uncorrected visual acuity of 20/20 or better; 93% and 89%, respectively, had a postoperative spherical equivalent refraction of +/-0.50 diopter. The differences between groups were not statistically significant. Wavefront-guided LASIK induced less change in 18 of 22 higher-order Zernike terms than wavefront-optimized LASIK, with the change in positive spherical aberration the only statistically significant one (P= .01). Contrast sensitivity improved at the low and middle spatial frequencies (not statistically significant) and worsened significantly at high spatial frequencies after wavefront-guided LASIK; there was a statistically significant worsening at all spatial frequencies after wavefront-optimized LASIK. Although both wavefront-guided and wavefront-optimized LASIK gave excellent refractive correction results, the former induced less higher-order aberrations and was associated with better contrast sensitivity.

  12. Using the combination refraction-reflection solid to design omni-directional light source used in underwater wireless optical communication

    Science.gov (United States)

    Rao, Jionghui; Yao, Wenming; Wen, Linqiang

    2015-10-01

    Underwater wireless optical communication is a communication technology which uses laser as an information carrier and transmits data through water. Underwater wireless optical communication has some good features such as broader bandwidth, high transmission rate, better security, anti—interference performance. Therefore, it is promising to be widely used in the civil and military communication domains. It is also suitable for high-speed, short-range communication between underwater mobile vehicles. This paper presents a design approach of omni-directional light source used in underwater wireless optical communication, using TRACEPRO simulation tool to help design a combination solid composed of the lens, conical reflector and parabolic reflector, and using the modulated DPSS green laser in the transmitter module to output the laser beam in small divergence angles, after expanded by the combination refraction-reflection solid, the angle turns into a space divergence angle of 2π, achieving the omni-directional light source of hemisphere space, and test in the air and underwater, the result shows that the effect is fine. This paper analyzes the experimental test in the air and water, in order to make further improvement of the uniformity of light distribution, we optimize the reflector surface parameters of combination refraction-reflection solid and test in the air and water. The result shows that omni-directional light source used in underwater wireless optical communication optimized could achieve the uniformity of light distribution of underwater space divergence angle of 2π. Omni-directional light source used in underwater wireless optical communication designed in this paper has the characteristics of small size and uniformity of light distribution, it is suitable for application between UUVs, AUVs, Swimmer Delivery Vehicles (SDVs) and other underwater vehicle fleet, it realizes point-to-multipoint communications.

  13. Selective cell culture on UV transparent polymer by F2 laser surface modification

    International Nuclear Information System (INIS)

    Hanada, Yasutaka; Sugioka, Koji; Kawano, Hiroyuki; Tsuchimoto, Takayoshi; Miyamoto, Iwao; Miyawaki, Atsushi; Midorikawa, Katsumi

    2009-01-01

    A microchip made of UV transparent polymer (CYTOP) that can perform selective cell culture has been fabricated by F 2 laser surface modification. The refractive index of CYTOP is almost the same as that of culture medium, which is essential for three-dimensional (3D) observation of cells. The F 2 laser modification of CYTOP achieves hydrophilicity only on the laser irradiated area with little deterioration of the optical properties and surface smoothness. After the laser modification, HeLa cells were successfully cultured and strongly adhered only on the modified area of CYTOP. The cells patterned on CYTOP were applied for clear 3D observation using an optical microscope in phase contrast mode.

  14. refractive errors among secondary school students in Isuikwuato

    African Journals Online (AJOL)

    Eyamba

    STUDENTS IN ISUIKWUATO LOCAL GOVERNMENT AREA OF ... the prevalence and types of refractive errors among secondary school students ... KEYWORDS: Refractive error, Secondary School students, ametropia, .... interviews of the teachers as regards the general performance of those students with obvious visual.

  15. Laser schlieren deflectometry for temperature analysis of filamentary non-thermal atmospheric pressure plasma.

    Science.gov (United States)

    Schäfer, J; Foest, R; Reuter, S; Kewitz, T; Šperka, J; Weltmann, K-D

    2012-10-01

    The heat convection generated by micro filaments of a self-organized non-thermal atmospheric pressure plasma jet in Ar is characterized by employing laser schlieren deflectometry (LSD). It is demonstrated as a proof of principle, that the spatial and temporal changes of the refractive index n in the optical beam path related to the neutral gas temperature of the plasma jet can be monitored and evaluated simultaneously. The refraction of a laser beam in a high gradient field of n(r) with cylindrical symmetry is given for a general real refraction index profile. However, the usually applied Abel approach represents an ill-posed problem and in particular for this plasma configuration. A simple analytical model is proposed in order to minimize the statistical error. Based on that, the temperature profile, specifically the absolute temperature in the filament core, the FWHM, and the frequencies of the collective filament dynamics are obtained for non-stationary conditions. For a gas temperature of 700 K inside the filament, the presented model predicts maximum deflection angles of the laser beam of 0.3 mrad which is in accordance to the experimental results obtained with LSD. Furthermore, the experimentally obtained FWHM of the temperature profile produced by the filament at the end of capillary is (1.5 ± 0.2) mm, which is about 10 times wider than the visual radius of the filament. The obtained maximum temperature in the effluent is (450 ± 30) K and is in consistence with results of other techniques. The study demonstrates that LSD represents a useful low-cost method for monitoring the spatiotemporal behaviour of microdischarges and allows to uncover their dynamic characteristics, e.g., the temperature profile even for challenging diagnostic conditions such as moving thin discharge filaments. The method is not restricted to the miniaturized and self-organized plasma studied here. Instead, it can be readily applied to other configurations that produce measurable

  16. Laser schlieren deflectometry for temperature analysis of filamentary non-thermal atmospheric pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, J.; Foest, R.; Reuter, S.; Weltmann, K.-D. [INP Greifswald, Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany); Kewitz, T. [Institute of Experimental and Applied Physics, University Kiel, 24098 Kiel (Germany); Sperka, J. [Department of Physical Electronics, Masaryk University, 61137 Brno (Czech Republic)

    2012-10-15

    The heat convection generated by micro filaments of a self-organized non-thermal atmospheric pressure plasma jet in Ar is characterized by employing laser schlieren deflectometry (LSD). It is demonstrated as a proof of principle, that the spatial and temporal changes of the refractive index n in the optical beam path related to the neutral gas temperature of the plasma jet can be monitored and evaluated simultaneously. The refraction of a laser beam in a high gradient field of n(r) with cylindrical symmetry is given for a general real refraction index profile. However, the usually applied Abel approach represents an ill-posed problem and in particular for this plasma configuration. A simple analytical model is proposed in order to minimize the statistical error. Based on that, the temperature profile, specifically the absolute temperature in the filament core, the FWHM, and the frequencies of the collective filament dynamics are obtained for non-stationary conditions. For a gas temperature of 700 K inside the filament, the presented model predicts maximum deflection angles of the laser beam of 0.3 mrad which is in accordance to the experimental results obtained with LSD. Furthermore, the experimentally obtained FWHM of the temperature profile produced by the filament at the end of capillary is (1.5 {+-} 0.2) mm, which is about 10 times wider than the visual radius of the filament. The obtained maximum temperature in the effluent is (450 {+-} 30) K and is in consistence with results of other techniques. The study demonstrates that LSD represents a useful low-cost method for monitoring the spatiotemporal behaviour of microdischarges and allows to uncover their dynamic characteristics, e.g., the temperature profile even for challenging diagnostic conditions such as moving thin discharge filaments. The method is not restricted to the miniaturized and self-organized plasma studied here. Instead, it can be readily applied to other configurations that produce measurable

  17. Estimation of network parameters with consideration of the horizontal refraction influence

    Directory of Open Access Journals (Sweden)

    Ján Ježko

    2007-06-01

    Full Text Available The proposed paper is focused on reviewing the horizontal refraction during measurement in local geodetic networks. Based on elaborated theoretical assumptions the refraction model was arranged in a way that the questions were solved by the identity of the horizontal refraction. The necessary part of the application of the refraction model is the problem of optimizing the geodetic networks and deducting the method of the variance components, which play a major role in the precision of results. The independent acquisition of the thesis lies in the area of modeling the horizontal refraction with a stochastic approach, where the values of the refraction are gained through the measured data of the horizontal direction. In the model, it is necessary to identify the parameters according to the entire measurements and between two points. According to the attained results, I can state that the horizontal refraction was identified mainly on the measurements that were confirmed near the dam in most of the measured experiments. The experimented measurements were confirmed based on the assumptions that are in theoretical capitol, where the assumptions of the effect of the horizontal refraction are measured near the dam, river, shores, and valleys.

  18. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    Science.gov (United States)

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  19. Phase-Modulation Laser Interference Microscopy

    DEFF Research Database (Denmark)

    Brazhe, Alexey; Brazhe, Nadezda; Maximov, G. V.

    2008-01-01

    We describe how phase-modulation laser interference microscopy and wavelet analysis can be applied to noninvasive nonstained visualization and study of the structural and dynamical properties of living cells. We show how phase images of erythrocytes can reveal the difference between various...... erythrocyte forms and stages of hemolysis and how phase images of neurons reveal their complex intracellular structure. Temporal variations of the refractive index are analyzed to detect cellular rhythmic activity on different time scales as well as to uncover interactions between the cellular processes....

  20. Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer.

    Science.gov (United States)

    Frings, Andreas; Linke, Stephan J; Bauer, Eva L; Druchkiv, Vasyl; Katz, Toam; Steinberg, Johannes

    2015-01-01

    This study was initiated to evaluate biomechanical changes using the Corvis ST tonometer (CST) on the cornea after laser in situ keratomileusis (LASIK). University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. Retrospective cohort study. This retrospective study included 37 eyes of 37 refractive patients. All CST measurements were performed 1 day before surgery and at the 1-month follow-up examination. The LASIK procedure included mechanical flap preparation using a Moria SBK microkeratome and an Allegretto excimer laser platform. Statistically significant differences were observed for mean first applanation length, mean first and second deflection lengths, mean first and second deflection amplitudes, radius of curvature, and peak distance. Significant positive correlations were found between the change (Δ) of radius of curvature and manifest refraction spherical equivalent (MRSE), ablation depth, and Δintraocular pressure as well as between AD and ΔHC-time. Each diopter of myopic correction in MRSE resulted in an increase in Δradius of curvature of 0.2 mm. Several CST parameters were statistically significantly altered by LASIK, thereby indicating that flap creation, ablation, or both, significantly change the ability of the cornea to absorb or dissipate energy.

  1. Highly efficient channel waveguide lasers at 1 µm and 2 µm in refractive-index-engineered potassium double tungstates

    NARCIS (Netherlands)

    van Dalfsen, Koop; Geskus, D.; García Blanco, Sonia Maria; Pollnau, Markus

    Epitaxial growth of rare-earth-ion-activated KY(1-x-y)Gd(x)Lu(y)(WO4)2 co-doped thin layers onto KY(WO4)2 substrates has enabled lattice-matched waveguides with high refractive-index contract and large variation of the active rare-earth-ion concentration. In Yb3+-activated micro-structured channel

  2. Laser radiation forces in laser-produced plasmas

    International Nuclear Information System (INIS)

    Stamper, J.A.

    1975-01-01

    There are two contributions to laser radiation forces acting on the electrons. Transfer of momentum from the fields to the electrons results in a field pressure contribution and occurs whenever there is absorption or reflection. The quiver pressure contribution, associated with electron quiver motion, is due to inhomogeneous fields inducing momentum transfer within the electron system. It is shown that the ponderomotive force with force density, (epsilon-1)/8πdel 2 >, does not include the field contribution and does not lead to a general description of macroscopic processes. A theory is discussed which does give a general macroscopic description (absorption, reflection, refraction, and magnetic field generation) and which reduces to the ponderomotive force for purely sinusoidal fields in a neutral, homogeneous, nonabsorbing plasma

  3. Comparison of photorefractive keratectomy and laser in situ keratomileusis for myopia of -6 D or less using the Nidek EC-5000 laser.

    Science.gov (United States)

    Fernández, A P; Jaramillo, J; Jaramillo, M

    2000-01-01

    We compared the efficacy, predictability, and safety of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for the surgical correction of low and moderate myopia. A retrospective study was performed to evaluate uncorrected and spectacle-corrected visual acuity, and manifest refraction 1 year after PRK or LASIK. All procedures were done using an automatic microkeratome (Chiron Ophthalmic) and the Nidek EC-5000 excimer laser. PRK was performed in 75 eyes of 45 patients and LASIK in 133 eyes of 77 patients. Mean age for PRK patients was 32.8 years (range, 18 to 52 yr) and LASIK patients was 29.6 years (range, 18 to 49 yr). Mean preoperative spherical equivalent refraction for PRK patients was -3.28 D (range, -1.00 to -6.00 D) and LASIK, -3.86 D (range, -1.00 to -6.00 D). One year after surgery, mean spherical equivalent refraction for Group 1 (baseline, -1.00 to -3.00 D) PRK eyes was -0.18 +/- 0.61 D (range, -1.50 to +0.75 D) and for LASIK eyes, -0.08 +/- 0.61 D (range, -1.50 to +1.62 D), with no statistically significant difference. For Group 2 eyes (baseline, -3.25 to -6.00 D), mean spherical equivalent refraction for PRK eyes was -0.44 +/- 0.87 D (range, -2.00 to +2.12 D) and for LASIK eyes, -0.09 +/- 0.83 D (range, -1.50 to +1.75 D), with no statistically significant difference. The antilogarithm of the mean UCVA (antilogUCVA) in Group 1 for PRK was 0.79 +/- 0.21 (20/25) and for LASIK was 0.87 +/- 0.19 (20/23), with no statistically significant difference. The antilogUCVA in Group 2 for PRK eyes was 0.70 +/- 0.24 (20/28) and for LASIK eyes was 0.83 +/- 0.18 (20/24), with a statistically significant difference (0.7 vs. 0.83, P 20/40 in Group 1 for PRK was 91.5% (38 eyes) and for LASIK was 95% (50 eyes) (no statistically significant difference), and in Group 2 for PRK eyes, it was 82% (27 eyes) and 97.5% (78 eyes) for LASIK (statistically significant difference, P PRK and LASIK with the Nidek EC-5000 excimer laser are effective and safe for

  4. Pressure-dependent refractive indices of gases by THz time-domain spectroscopy.

    Science.gov (United States)

    Sang, Bark Hyeon; Jeon, Tea-In

    2016-12-12

    Noncontact terahertz time-domain spectroscopy was employed to measure pressure-dependent refractive indices of gases such as helium (He), argon (Ar), krypton (Kr), oxygen (O2), nitrogen (N2), methane (CH4), and carbon dioxide (CO2). The refractive indices of these gases scaled linearly with pressure, for pressures in the 55-3,750 torr range. At the highest pressure, the refractive indices ((n-1) x 106) of He and CO2 were 170 and 2,390, respectively. The refractive index of CO2 was 14.1-fold higher than that of He, owing to the stronger polarizability of CO2. Although the studied gases differed in terms of their molecular structure, their refractive indices were strongly determined by polarizability. The measured refractive indices agreed well with the theoretical calculations.

  5. Laser-Induced Motion of a Nanofluid in a Micro-Channel

    Directory of Open Access Journals (Sweden)

    Tran X. Phuoc

    2016-10-01

    Full Text Available Since a photon carries both energy and momentum, when it interacts with a particle, photon-particle energy and momentum transfer occur, resulting in mechanical forces acting on the particle. In this paper we report our theoretical study on the use of a laser beam to manipulate and control the flow of nanofluids in a micro-channel. We calculate the velocity induced by a laser beam for TiO2, Fe2O3, Al2O3 MgO, and SiO2 nanoparticles with water as the base fluid. The particle diameter is 50 nm and the laser beam is a 4 W continuous beam of 6 mm diameter and 532 nm wavelength. The results indicate that, as the particle moves, a significant volume of the surrounding water (up to about 8 particle diameters away from the particle surface is disturbed and dragged along with the moving particle. The results also show the effect of the particle refractive index on the particle velocity and the induced volume flow rate. The velocity and the volume flowrate induced by the TiO2 nanoparticle (refractive index n = 2.82 are about 0.552 mm/s and 9.86 fL, respectively, while those induced by SiO2 (n = 1.46 are only about 7.569 μm/s and 0.135, respectively.

  6. Particle sizing experiments with the laser Doppler velocimeter: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Giel, T.V. Jr.; Son, J.Y.

    1988-06-01

    Measurement techniques for in-situ simultaneous measurements of particle size distributions and particle velocities using the dual beam laser Doppler velocimeter (LV) were analytically and experimentally investigated. This investigation examined the different signal characteristics of the LV for determination of particle size and particle velocity, simultaneously. The different size related signal components were evaluated not only singularly but also as simultaneous measurements to determine which characteristic, or combination of characteristics, provided the best measure of particle size. The evaluation concentrated on the 0.5 to 5 ..mu..m particle size range, in which the LV light scattering characteristics are complex often non-monotonic functions of the particle size as well as functions of index of refraction, the laser light wavelength, laser intensity and polarization, and the location and response characteristics of the detector. Different components of the LV signal were considered, but analysis concentrated on Doppler phase, visibility and scatter-intensity because they show the greatest promise. These signals characteristics were initially defined analytically for numerous optical configurations over the 0.5 to 5 ..mu..m diameter range with 0.1 ..mu..m segmentation, for refractive index values from 1.0 to 3.0 with absorptive (imaginary) components varied form 0 to 1.0. Collector orientation and effective f/No., as well as fringe spacing, beam polarization and wavelength, were varied in this analytical evaluation. 18 refs., 42 figs., 5 tabs.

  7. Pediatric PRK (PhotoRefractive Keratectomy) with Mitomycin C (MCC) for Persistent Anisometropic Amblyopia. A Case Report.

    Science.gov (United States)

    Crawford, Courtney M; Frazier, Travis C; Torres, Mark F; Arnold, Robert W; Mazzoli, Robert A; Raymond, William R

    2012-01-01

    To evaluate the safety and efficacy of photorefractive keratectomy (PRK) with Mitomycin C (MMC) for the treatment of severe pediatric anisometropia and amblyopia resistant to more conservative treatment modalities. A 3 year-old-child, who at 18 months old underwent unilateral diode laser treatment for threshold ROP, developed 11 diopters of anisometropic myopia and secondary dense amblyopia of the Right Eye. Only after all conservative treatment options failed was he treated with PRK and MMC. Principal outcome measures included cycloplegic refraction, the amount of refractive correction, degree of corneal haze and change in visual acuity. On presentation: BCVA: 20/CF OD; 20/30 OS. CRNS: -11.50 diopters sphere OD; -0.50 diopters sphere OS. Unilateral PRK followed by application of MMC (0.2 mg/ml) for 1 min was performed under general anesthesia. Three-month postoperative findings include: VA: 20/30 OD; 20/25 OS. CRNS: +0.25 diopters sphere OD. At one year, the BCVA remained equal at the 20/30 level despite mild myopic regression OD. CRNS OD at one year was -1.25 +050 x 116. No corneal haze was appreciated. In this child, treatment with PRK and MMC safely reduced the anisometropia thus facilitating his visual rehabilitation. While encouraging, further study is required to verify the longer term results of this single case. To evaluate the safety and efficacy of photorefractive keratectomy (PRK) with Mitomycin C (MMC) for the treatment of severe pediatric anisometropia and amblyopia resistant to more conservative treatment modalities. A 3 year-old-child, who at 18 months old underwent unilateral diode laser treatment for threshold ROP, developed 11 diopters of anisometropic myopia and secondary dense amblyopia of the Right Eye. Only after all conservative treatment options failed was he treated with PRK and MMC. Principal outcome measures included cycloplegic refraction, the amount of refractive correction, degree of corneal haze and change in visual acuity. On

  8. Forensic comparative glass analysis by laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Bridge, Candice M.; Powell, Joseph; Steele, Katie L.; Sigman, Michael E.

    2007-01-01

    Glass samples of four types commonly encountered in forensic examinations have been analyzed by laser-induced breakdown spectroscopy (LIBS) for the purpose of discriminating between samples originating from different sources. Some of the glass sets were also examined by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). Refractive index (RI) measurements were also made on all glass samples and the refractive index data was combined with the LIBS and with the LA-ICP-MS data to enhance discrimination. The glass types examined included float glass taken from front and side automobile windows (examined on the non-float side), automobile headlamp glass, automobile side-mirror glass and brown beverage container glass. The largest overall discrimination was obtained by employing RI data in combination with LA-ICP-MS (98.8% discrimination of 666 pairwise comparisons at 95% confidence), while LIBS in combination with RI provided a somewhat lower discrimination (87.2% discrimination of 1122 pairwise comparisons at 95% confidence). Samples of side-mirror glass were less discriminated by LIBS due to a larger variance in emission intensities, while discrimination of side-mirror glass by LA-ICP-MS remained high

  9. One-year follow-up of femtosecond laser-assisted penetrating keratoplasty

    Directory of Open Access Journals (Sweden)

    Tan JCH

    2013-02-01

    Full Text Available Johnson Choon-Hwai Tan, Wee-Jin HengNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, SingaporeBackground: The purpose of this report is to describe the initial outcomes of femtosecond laser-assisted penetrating keratoplasty.Methods: This retrospective surgical case series consisted of 10 eyes from 10 patients undergoing penetrating keratoplasty at a tertiary center. Femtosecond laser was used to perform a zig-square incision on the donor cornea with matched dimensions on the recipient cornea. Outcomes measured included: unaided visual acuity and best spectacle-corrected visual acuity preoperatively and at one, 3, 6, and 12 months postoperatively; manifest refractive and topographic astigmatism at 3, 6, and 12 months postoperatively; and endothelial cell density loss, calculated at the end of the one-year follow-up period.Results: At one-year follow-up, there was an improvement in unaided visual acuity from a mean preoperative logMAR of 1.67 to 0.44, and best spectacle-corrected visual acuity from a mean preoperative logMAR of 1.33 to 0.13. By postoperative month 3, mean manifest refractive and topographic astigmatism was 2.31 ± 1.41 D and 2.59 ± 1.57 D, respectively. The mean reduction in endothelial cell density was 20.7% after one year of follow-up.Conclusion: Femtosecond laser-assisted penetrating keratoplasty provided a good visual outcome and early visual rehabilitation due to precise graft-host alignment and reduced astigmatism in the early postoperative months.Keywords: penetrating keratoplasty, femtosecond laser-assisted keratoplasty

  10. Laser-assisted subepithelial keratectomy (LASEK) versus laser-assisted in-situ keratomileusis (LASIK) for correcting myopia.

    Science.gov (United States)

    Kuryan, Jocelyn; Cheema, Anjum; Chuck, Roy S

    2017-02-15

    Near-sightedness, or myopia, is a condition in which light rays entering the eye along the visual axis focus in front of the retina, resulting in blurred vision. Myopia can be treated with spectacles, contact lenses, or refractive surgery. Options for refractive surgery include laser-assisted subepithelial keratectomy (LASEK) and laser-assisted in-situ keratomileusis (LASIK). Both procedures utilize a laser to shape the corneal tissue (front of the eye) to correct refractive error, and both create flaps before laser treatment of corneal stromal tissue. Whereas the flap in LASEK is more superficial and epithelial, in LASIK it is thicker and also includes some anterior stromal tissue. LASEK is considered a surface ablation procedure, much like its predecessor, photorefractive keratectomy (PRK). LASEK was developed as an alternative to PRK to address the issue of pain associated with epithelial debridement used for PRK. Assessing the relative benefits and risks/side effects of LASEK and LASIK warrants a systematic review. To assess the effects of LASEK versus LASIK for correcting myopia. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), which contains the Cochrane Eyes and Vision Trials Register (2016, Issue 10); MEDLINE Ovid (1946 to 24 October 2016); Embase.com (1947 to 24 October 2016); PubMed (1948 to 24 October 2016); LILACS (Latin American and Caribbean Health Sciences Literature Database; 1982 to 24 October 2016); the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), last searched 20 June 2014; ClinicalTrials.gov (www.clinicaltrials.gov); searched 24 October 2016; and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 24 October 2016. We did not use any date or language restrictions in the electronic searches for trials. We considered only randomized controlled trials (RCTs) for the purposes of this review. Eligible RCTs were those in which myopic participants were

  11. A hybrid plasmonic waveguide terahertz quantum cascade laser

    Energy Technology Data Exchange (ETDEWEB)

    Degl' Innocenti, Riccardo, E-mail: rd448@cam.ac.uk; Shah, Yash D.; Wallis, Robert; Klimont, Adam; Ren, Yuan; Jessop, David S.; Beere, Harvey E.; Ritchie, David A. [Cavendish Laboratory, University of Cambridge, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom)

    2015-02-23

    We present the realization of a quantum cascade laser emitting at around 2.85 THz, based on a hybrid plasmonic waveguide with a low refractive index dielectric cladding. This hybrid waveguide design allows the performance of a double-metal waveguide to be retained, while improving the emission far-field. A set of lasers based on the same active region material were fabricated with different metal layer thicknesses. A detailed characterization of the performance of these lasers revealed that there is an optimal trade-off that yields the best far-field emission and the maximum temperature of operation. By exploiting the pure plasmonic mode of these waveguides, the standard operation conditions of a double-metal quantum cascade laser were retrieved, such that the maximum operating temperature of these devices is not affected by the process. These results pave the way to realizing a class of integrated devices working in the terahertz range which could be further exploited to fabricate terahertz on-chip circuitry.

  12. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  13. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  14. Studies of closure phenomena in pinholes irradiated by Nd laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, J.M.; Holmes, N.C.; Hunt, J.T.; Linford, G.J.

    1978-08-21

    The plasma closure of spatial filter pinholes is a critical parameter in the performance of high energy glass laser systems. Using 50 to 100 J, 300 psec FWHM laser pulses on the Janus laser, an investigation has been made on closure effects in 300 ..mu..m to 500 ..mu..m diameter pinholes of various materials and thicknesses. Calorimetry measurements have yielded data on pinhole transmission and intensity loading on the periphery of the pinhole. Ultrafast streak photography measurements indicate effective closure velocities of 2 x 10/sup 7/ cm/sec to 5 x 10/sup 7/ cm/sec. Scattered light measurements have shown the transmission loss through a typical spatial filter configuration to be primarily refractive in nature.

  15. Studies of closure phenomena in pinholes irradiated by Nd laser pulses

    International Nuclear Information System (INIS)

    Auerbach, J.M.; Holmes, N.C.; Hunt, J.T.; Linford, G.J.

    1978-01-01

    The plasma closure of spatial filter pinholes is a critical parameter in the performance of high energy glass laser systems. Using 50 to 100 J, 300 psec FWHM laser pulses on the Janus laser, an investigation has been made on closure effects in 300 μm to 500 μm diameter pinholes of various materials and thicknesses. Calorimetry measurements have yielded data on pinhole transmission and intensity loading on the periphery of the pinhole. Ultrafast streak photography measurements indicate effective closure velocities of 2 x 10 7 cm/sec to 5 x 10 7 cm/sec. Scattered light measurements have shown the transmission loss through a typical spatial filter configuration to be primarily refractive in nature

  16. Measurement of Refractive Index Using a Michelson Interferometer.

    Science.gov (United States)

    Fendley, J. J.

    1982-01-01

    Describes a novel and simple method of measuring the refractive index of transparent plates using a Michelson interferometer. Since it is necessary to use a computer program when determining the refractive index, undergraduates could be given the opportunity of writing their own programs. (Author/JN)

  17. Self-organization of high intensity laser pulses propagating in gases

    International Nuclear Information System (INIS)

    Koga, James

    2001-01-01

    In recent years the development of high intensity short pulse lasers has opened up wide fields of science which had previously been difficult to study. Recent experiments of short pulse lasers propagating in air have shown that these laser pulses can propagate over very long distances (up to 12 km) with little or no distortion of the pulse. Here we present a model of this propagation using a modified version of the self-organized criticality model developed for sandpiles by Bak, Tang, and Weisenfeld. The additions to the sandpile model include the formation of plasma which acts as a threshold diffusion term and self-focusing by the nonlinear index of refraction which acts as a continuous inverse diffusion. Results of this simple model indicate that a strongly self-focusing laser pulse shows self-organized critical behavior. (author)

  18. Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

    Science.gov (United States)

    Jankov, Mirko R; Panagopoulou, Sophia I; Tsiklis, Nikolaos S; Hajitanasis, Georgos C; Aslanides, loannis M; Pallikaris, loannis G

    2006-04-01

    To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and

  19. High-Power, High-Intensity Laser Propagation and Interactions

    Science.gov (United States)

    2014-03-10

    intensity as the weighting function. The full refractive index associated with the laser plasma interaction having a parabolic density variation ...radiation in turn enhances the electron density wave further amplifying the radiation. Considering spatial variations in the z direction only the FEL...effL/ at the entrance to the wiggler where effL is the effective interaction length. This requirement can be expressed by the following inequality

  20. Nd:YAG laser for epithelial ingrowth after laser in situ keratomileusis.

    Science.gov (United States)

    Mohammed, Osama Ali; Mounir, Amr; Hassan, Amin Aboali; Alsmman, Alahmady Hamad; Mostafa, Engy Mohamed

    2018-05-04

    To evaluate the efficacy of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser for treatment of epithelial ingrowth after laser in situ keratomileusis (LASIK). Fifty-eight patients with epithelial ingrowth presented to Sohag refractive center, Sohag, Egypt, between January 2015 and March 2017. Only 41 patients (18 females and 23 males, mean age: 33.4 years) involving 41 eyes were indicated for treatment by Nd:YAG laser as the rest of the eyes were only under observation. Patients with epithelial ingrowth were recognized at a mean of 6 months after primary LASIK procedure (range: 2-16 months). Four eyes had undergone previous LASIK enhancements. Four eyes had the epithelial ingrowth removed by flap lift and scrapping. The mean intensity of the spots used was 0.8 mJ with variable number of shots depending on the size and density of the epithelial ingrowth area. Twenty-eight eyes showed complete regression after one session, while the rest necessitated 2-3 sessions for complete resolution. Mean follow-up period was 8 months (range 5-12 months). Epithelial ingrowth was treated successfully in all 41 eyes. The uncorrected visual acuities were 20/20, and there was no evidence of recurrent epithelial ingrowth after 6 months with no complications reported. YAG laser is a simple, effective outpatient procedure for the management of epithelial ingrowth after LASIK.

  1. Resultados refractivos en pacientes operados por LASIK versus LASEK con mitomicina C Refractive results in patients operated by LASIK versus LASEK with Mitomycin C

    Directory of Open Access Journals (Sweden)

    Abel Cabrera Martínez

    2009-06-01

    Full Text Available OBJETIVO: Evaluar comparativamente los resultados refractivos obtenidos en ojos operados con el uso de la keratomileusis in situ asistida con láser (LASIK contra la keratomileusis subepitelial asistida con láser combinándosele a esta última el uso de la mitomicina C (LASEK+MC. MÉTODOS: Se realizó un estudio prospectivo, experimental, comparativo en un total de 210 ojos de pacientes que acudieron a consulta para ser operados por algún defecto refractivo. Un total de 104 ojos fueron intervenidos por LASIK y 106 por LASEK+MC. Para comparar los resultados del estudio se realizaron varios exámenes antes y después de operados los pacientes. RESULTADOS: Los defectos refractivos fueron superiores con significación estadística (pOBJECTIVE: Evaluating comparatively the refractive results obtained in eyes operated by keratomileusis in situ assisted with laser (LASIK versus keratomileusis subepithelial assisted with laser plus Mitomycin C (LASEK + MC. METHODS: A prospective, experimental and comparative study was performed in 210 eyes of patients who went to see the specialist to be operated from some refractive defect. A total of 104 eyes were operated by LASIK and 106 by LASEK + MC. In order to compare the results of study, several tests were made before and after surgery. RESULTS: The refractive defects were greater with statistical significance (p< 0,05, for Student's t for the eyes operated by LASEK + MC. The visual result of the LASEK with MC surgery was better than that of LASIK. Haze was a problem resolved for the LASEK when included Mitomycin C in patients with high myopia, in addition to improvement of quality of life of the patients. CONCLUSIONS: The corneal surgery with laser through the LASEK technique plus use of Mitomycin C demonstrated being as reliable as that with LASIK for ametropy correction, since it provides additional advantages that increases the quality of life of patient, with less postoperative risks.

  2. Perfect imaging without negative refraction

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom)], E-mail: ulf@st-andrews.ac.uk

    2009-09-15

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional (2D) integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing may also find applications outside of optics, in acoustics, fluid mechanics or quantum physics, wherever waves obey the 2D Helmholtz equation.

  3. Laser parameters, focusing optics, and side effects in femtosecond laser corneal surgery

    Science.gov (United States)

    Plamann, Karsten; Nuzzo, Valeria; Peyrot, Donald A.; Deloison, Florent; Savoldelli, Michèle; Legeais, Jean-Marc

    2008-02-01

    Nowadays, femtosecond lasers are routinely used in refractive eye surgery. Until recently, commercialised clinical systems were exclusively based on ytterbium or neodymium-doped solid state lasers emitting sub-picosecond pulses at a wavelength of about 1 μm and repetition rates of a few 10 kHz. These systems use pulse energies in the μJ range and focussing optics of NA = 0.3 to 0.5. Recent developments have provided a variety of alternative and equally viable approaches: systems are now available using nJ pulses at high numerical apertures and MHz repetition rates - an approach so far only used for femtosecond cell surgery - and fibre laser technology is now being used for femtosecond laser corneal surgery. Recent research has also provided more insight in side effects occurring in present systems: self focusing phenomena and so far unexplained periodical structures have been observed even at high numerical apertures (NA >> 0.5) and moderate pulse energies. The interaction of femtosecond laser pulses with strongly scattering tissue has been studied in view of extending the application of femtosecond lasers to keratoplasty for opaque corneas and to glaucoma surgery. The use of new laser wavelengths and adaptive optics has been proposed. Despite the reputation of femtosecond surgical systems for their precision, repeatability and the absence of secondary effects or complications, a closer examination reveals the presence of subtle phenomena which merit further investigation. We present three of these phenomena: the influence of optical aberration on the quality of the incision, the occurrence of filamentation effects, and the deposit of microscopic glass fragments when performing penetrating incisions.

  4. THE PROPERTIES OF GUIDED ELECTROMAGNETIC FIELD MODES ON THE GaAs-BASED FIBER GLASS AND LASERS

    Directory of Open Access Journals (Sweden)

    Mustafa TEMİZ

    1999-03-01

    Full Text Available On the lasers or fiber optic communication electromagnetic waves are transmitted by confining and guiding between special layer's or fiber glass respectively. It is desired that electric and magnetic waves are in the active region of the lasers and in the core of the fiber glass. It is obtained by making more larger the of refractive index of the regions. On this work, the behavior and varying of the electric and magnetic waves and the effects on the electromagnetic waves in the fiber glass and lasers are investigated.

  5. A pure silica ytterbium-doped sol–gel-based fiber laser

    International Nuclear Information System (INIS)

    Baz, Assaad; El Hamzaoui, Hicham; Fsaifes, Ihsan; Bouwmans, Géraud; Bouazaoui, Mohamed; Bigot, Laurent

    2013-01-01

    In this letter it is demonstrated that the sol–gel route combined with fiber fabrication by the stack and draw method can be used to realize efficient fiber lasers. More precisely, a pure silica ytterbium-doped photonic crystal fiber with a core obtained by the sol–gel polymeric technique is studied, and a laser efficiency of more than 73% is achieved for a laser emission around 1034 nm. The optical and spectroscopic properties of the monolith and fiber are investigated, together with the sensitivity of the fiber to photodarkening. The dimensions of the ytterbium-doped monolith combined with the uniform doping and refractive index that are reported make this technique particularly interesting for the realization of large-mode area fibers. (letter)

  6. Compact Birefringent Waveplates Photo-Induced in Silica by Femtosecond Laser

    Directory of Open Access Journals (Sweden)

    Matthieu Lancry

    2014-09-01

    Full Text Available Recently, we showed that femtosecond laser induced “nanogratings” consist of thin regions with a low refractive index (Δn = −0.15, due to the formation of nanoporous silica surrounded by regions with a positive index change. In this paper, we investigate a wide range of laser parameters to achieve very high retardance within a single layer; as much as 350 nm at λ = 546 nm but also to minimize the competing losses. We show that the total retardance depends on the number of layers present and can be accumulated in the direction of laser propagation to values higher than 1600 nm. This opens the door to using these nanostructures as refined building blocks for novel optical elements based on strong retardance.

  7. Optical fibre cavity ring down measurement of refractive index with a microchannel drilled by femtosecond laser

    Science.gov (United States)

    Zhou, Kaiming; Webb, David; Mou, Chengbo; Farries, Mark; Hayes, Neil; Bennion, Ian

    2009-10-01

    μA microchannel was inscribed in the fibre of a ring cavity which was constructed from two 0.1%:99.9% couplers and a 10m fibre loop. Cavity ring down spectroscopy (CRDS) was used to measure the refractive index (RI) of gels infused into the microchannel with high resolution. The ring down time discloses a nonlinear increase with respect to the RI of the gel and sensitivity up to 300μs/RI unit (RIU) and resolution of 5×10-4 were obtained.

  8. The effects of the intense laser field on the nonlinear optical properties of a cylindrical Ga{sub 1−x}Al{sub x}As/GaAs quantum dot under applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Kasapoglu, E., E-mail: ekasap@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mora-Ramos, M.E. [Centro de Investigación en Ciencias, Instituto de Ciencias Básicas y Aplicadas, Universidad Autóonoma del Estado de Morelos, Av. Universidad 1001, CP 62209 Cuernavaca, Morelos (Mexico); Sökmen, I. [Department of Physics, Dokuz Eylül University, 35160 Buca, İzmir (Turkey)

    2015-10-01

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change (the linear and third-order nonlinear) for transitions between different intersubbands in the Ga{sub 1−x}Al{sub x}As/GaAs cylindrical quantum dot under external electric field are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass approximation. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the electric and intense laser fields. By changing the intensities of the electric and laser fields, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • The effects of the non-resonant intense laser field and electric field on the nonlinear optical properties of cylindrical quantum dot are investigated. • The both total absorption coefficient and refractive index change are sensitive to dot dimensions and the effects of external fields. • By changing the external fields together with dot dimensions a blue or red shift can be obtained.

  9. Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial.

    Science.gov (United States)

    Ang, Marcus; Tan, Donald; Mehta, Jodhbir S

    2012-05-31

    Small incision lenticule extraction or SMILE is a novel form of 'flapless' corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. This novel

  10. On the optical path length in refracting media

    Science.gov (United States)

    Hasbun, Javier E.

    2018-04-01

    The path light follows as it travels through a substance depends on the substance's index of refraction. This path is commonly known as the optical path length (OPL). In geometrical optics, the laws of reflection and refraction are simple examples for understanding the path of light travel from source to detector for constant values of the traveled substances' refraction indices. In more complicated situations, the Euler equation can be quite useful and quite important in optics courses. Here, the well-known Euler differential equation (EDE) is used to obtain the OPL for several index of refraction models. For pedagogical completeness, the OPL is also obtained through a modified Monte Carlo (MC) method, versus which the various results obtained through the EDE are compared. The examples developed should be important in projects involving undergraduate as well as graduate students in an introductory optics course. A simple matlab script (program) is included that can be modified by students who wish to pursue the subject further.

  11. Selective cell culture on UV transparent polymer by F{sub 2} laser surface modification

    Energy Technology Data Exchange (ETDEWEB)

    Hanada, Yasutaka, E-mail: y-hanada@riken.jp [RIKEN-Advanced Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Sugioka, Koji [RIKEN-Advanced Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Kawano, Hiroyuki [RIKEN-Brain Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Tsuchimoto, Takayoshi [RIKEN-Advanced Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Department of Applied Electronics, Faculty of Industrial Science and Technology Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510 (Japan); Miyamoto, Iwao [Department of Applied Electronics, Faculty of Industrial Science and Technology Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510 (Japan); Miyawaki, Atsushi [RIKEN-Brain Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Midorikawa, Katsumi [RIKEN-Advanced Science Institute, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)

    2009-09-30

    A microchip made of UV transparent polymer (CYTOP) that can perform selective cell culture has been fabricated by F{sub 2} laser surface modification. The refractive index of CYTOP is almost the same as that of culture medium, which is essential for three-dimensional (3D) observation of cells. The F{sub 2} laser modification of CYTOP achieves hydrophilicity only on the laser irradiated area with little deterioration of the optical properties and surface smoothness. After the laser modification, HeLa cells were successfully cultured and strongly adhered only on the modified area of CYTOP. The cells patterned on CYTOP were applied for clear 3D observation using an optical microscope in phase contrast mode.

  12. Refractive index sensing based on higher-order mode reflection of a microfiber Bragg grating.

    Science.gov (United States)

    Zhang, Yu; Lin, Bo; Tjin, Swee Chuan; Zhang, Han; Wang, Guanghui; Shum, Ping; Zhang, Xinliang

    2010-12-06

    A fiber Bragg grating written in a photosensitive microfiber using KrF excimer laser via a uniform phase mask is demonstrated. We have successfully fabricated two Bragg gratings in microfibers having different diameters. In the reflection spectrum of a microfiber Bragg grating (MFBG), we observed two reflection peaks,which agrees with our numerical simulation results. Compared with the fundamental mode reflection, the higher-order reflection mode is more sensitive to the refractive index (RI) variation of the surrounding fluid due to its larger evanescent field. The measured maximum sensitivity is ~102 nm/RIU (RI unit) at an RI value of 1.378 in an MFBG with a diameter of 6 μm.

  13. Laser formation of Bragg gratings in polymer nanocomposite materials

    Energy Technology Data Exchange (ETDEWEB)

    Nazarov, M M; Khaydukov, K V; Sokolov, V I; Khaydukov, E V [Institute on Laser and Information Technologies, Russian Academy of Sciences, Shatura, Moscow Region (Russian Federation)

    2016-01-31

    The method investigated in this work is based on the laser-induced, spatially inhomogeneous polymerisation of nanocomposite materials and allows control over the motion and structuring of nanoparticles. The mechanisms of nanoparticle concentration redistribution in the process of radical photopolymerisation are studied. It is shown that under the condition of spatially inhomogeneous illumination of a nanocomposite material, nanoparticles are diffused from the illuminated areas into the dark fields. Diffraction gratings with a thickness of 8 μm and a refractive index modulation of 1 × 10{sup -2} are written in an OCM-2 monomer impregnated by silicon nanoparticles. The gratings may be used in the development of narrowband filters, in holographic information recording and as dispersion elements in integrated optical devices. (interaction of laser radiation with matter. laser plasma)

  14. Photorefractive keratectomy in refractive accommodative esotropia.

    Science.gov (United States)

    Bilgihan, K; Akata, F; Or, M; Hasanreisoğlu, B

    1997-01-01

    Photorefractive keratectomy (PRK) was performed on a 19-year-old man with hyperopic astigmatism and refractive accommodative esotropia. The patient was orthophoric while wearing spectacles, but had an esotropia of 30 prism dioptres at near and distance vision without spectacles. The best corrected visual acuity of the right eye was 20/50 and of the left eye was 20/20. The excessive accommodative convergence of the patient was eliminated by correcting the hyperopic refractive error by performing PRK, and the patient became orthophoric after the treatment.

  15. High-power Yb- and Tm-doped double tungstate channel waveguide lasers

    NARCIS (Netherlands)

    van Dalfsen, Koop; Geskus, D.; Ay, F.; Worhoff, Kerstin; Aravazhi, S.; Pollnau, Markus

    The potassium double tungstates KGd(WO4)2, KY(WO4)2, and KLu(WO4)2 are excellent candidates for solid-state lasers because of their high refractive index of ~2.0-2.1, the large transition cross-sections of rare-earth (RE3+) ions doped into these hosts, and a reasonably large thermal conductivity of

  16. Refractive Errors in State Junior High School Students in Bandung

    Directory of Open Access Journals (Sweden)

    Sabila Tasyakur Nikmah

    2016-12-01

    Full Text Available Background: Uncorrected refractive error is one of the avoidable causes of vision impairment in children and adults. Vision problem in children has been shown to affect their psychological and academic performance. This study aims at identifying and gaining more insights on the characteristic of the refractive errors in state junior high school students in Bandung to avoid uncorrected refractive errors. Methods: A cross-sectional study was conducted in September–November 2015 in state junior high schools in Bandung, West Java, Indonesia. Sample was selected using multistage random sampling technique. Children were examined using tumbling E examination; then students with visual acuity worse than 6/12 underwent Snellen Chart test, refractometry without pupil dilatation, correction with trial lens, then was followed by direct ophthalmoscopy. Results: From a total of 435 children who completed all the examination, 80 children (18.39% had refractive errors; consisted of 151 eyes (94.38% with myopia and 9 eyes (5.62% with astigmatism. Refractive errors were found to be more common in female children (73.7% than male children (26.3%. Among those with refractive errors, 45 children (56.3% did not use any corrective glasses before the examination. Conclusions: Routine refractive error test in vision screening examination is needed for students. It is equally important to raise more awareness toward eye disease in community.

  17. Nondestructive measurement of refractive index profile of optical fiber preforms using moire technique and phase shift method

    Science.gov (United States)

    Ranjbar, Samaneh; Khalesifard, Hamid R.; Rasouli, Saifollah

    2006-01-01

    The refractive index profile of optical fiber preform is measured by a nondestructive technique based on Talbot interferometry. In this technique the preform is placed between two ronchi ruling gratings of 10 lines/mm and the system is illuminated by an expanded and collimated beam of He-Ne laser. In this arrangement the 2nd grating is positioned in the Talbot image of the 1st grating and the preform axis is parallel to the gratings planes. To eliminate the effect of clad on the light beam deflection during the measurements, the preform is immersed in an index matching liquid. The phase front of the laser light over the 2nd grating can be monitored by analysis of the moire pattern which is formed over there. The analysis is done by means of 4-step phase shift technique. In this technique the second grating is moved in four steps of 1/4 of the grating vector and in each step the intensity profile of the moire pattern is recorded. The phasefront can be specified by using the recorded intensities. The refractive index profile of the preform can be calculated from the changes on phasefront while the preform is placed between the gratings respect to the case when it is absent. The whole procedure is automated and computer controlled by using a CCD camera to record the moire fringes, a stepper motor for linear translation of the 2nd grating and a code in MATLAB to control the system and measurements.

  18. Atmosphere Refraction Effects in Object Locating for Optical Satellite Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    YAN Ming

    2015-09-01

    Full Text Available The collinear rigorous geometric model contains the atmosphere refraction geometric error in off-nadir observation. In order to estimate and correct the atmosphere refraction geometric error, the ISO international standard atmospheric model and Owens atmosphere refractive index algorithm are applied to calculate the index of atmosphere refraction in different latitude and altitude. The paper uses the weighted mean algorithm to reduce the eight layers ISO standard atmospheric model into a simple troposphere and stratosphere two layers spherical atmosphere. And the LOS vector track geometric algorithm is used to estimate the atmosphere refraction geometric error in different observation off-nadir angle. The results show that the atmosphere refraction will introduce about 2.5 m or 9 m geometric displacement in 30 or 45 degree off-nadir angle individual. Therefore, during geo-location processing of agile platform and extra wide high spatial resolution imagery, there is need to take into account the influence of atmosphere refraction and correct the atmosphere refraction geometric error to enhance the geo-location precision without GCPs.

  19. Prevalence of Refractive errors among Primary School Pupils in ...

    African Journals Online (AJOL)

    Administrator

    Effective management of blindness due to refractive errors is readily available in developed countries. 1 ... Key words: Refractive errors, Children, Prevalence, Kenya. 165 .... financial support towards the funding of this study. REFERENCES. 1.

  20. The application of excimer lasers for corneal sculpturing

    International Nuclear Information System (INIS)

    King, M.C.

    1990-01-01

    Of the broad selection of lasers available for surgery, the argon fluoride excimer laser offers a set of attributes that make it uniquely suited for the removal of corneal tissue. With ultraviolet radiation at 193mm, the energy of an individual photon (6.3 electron volts) is sufficient to break bonds in protein molecules without generating molecular vibration (heat). A single laser pulse is capable of removing 0.25 microns of corneal tissue over a well defined area 80 mm 2 in extent. This excision with a lateral precision to a fraction of a micron causes no discernible damage to neighboring cells. The smooth surface left after the tissue is removed promotes a quick and predictable regrowth of the epithelium. The penetration of radiation into the underlying tissue is the order of a micron so there is no potential harm to the lens or retinal tissue. Insignificant mutagenesis or unscheduled DNA synthesis has been detected as a result of tissue irradiation at this wavelength. In the past few years major progress has been made towards developing ophthalmic procedures which utilize the unique properties of this laser. To date there are FDA IDE's (Investigational Device Exemptions) for the following procedures: Photorefractive Keratectomy (PRK) or corneal reshaping for correcting near-sightedness, far-sightedness and astigmatism without the need for eye glasses, contact lenses or conventional refractive surgery (Radial Keratotomy); Partial Excimer Trabeculectomy for relieving the pressure build-up caused by glaucoma; T-Excisons for reducing astigmatism; Myopic Keratomileusis (MKM) for the refractive correction of severe myopia; superficial Keratectomy (corneal smoothing) for treating various corneal scars, dystrophies, recurrent corneal erosion etc. In this paper the fundamentals of beam tissue interaction at 193nm will be discussed