  1. Laser-induced thermal desorption of aniline from silica surfaces

    Science.gov (United States)

    Voumard, Pierre; Zenobi, Renato

    1995-10-01

    A complete study on the energy partitioning upon laser-induced thermal desorption of aniline from silica surfaces was undertaken. The measurements include characterization of the aniline-quartz adsorption system using temperature-programmed desorption, the extrapolation of quasiequilibrium desorption temperatures to the regime of laser heating rates on the order of 109-1010 K/s by computational means, measurement of the kinetic energy distributions of desorbing aniline using a pump-probe method, and the determination of internal energies with resonance-enhanced multiphoton ionization spectroscopy. The measurements are compared to calculations of the surface temperature rise and the resulting desorption rates, based on a finite-difference mathematical description of pulsed laser heating. While the surface temperature of laser-heated silica reaches about 600-700 K at the time of desorption, the translational temperature of laser-desorbed aniline was measured to be Tkin=420±60 K, Tvib was 360±60 K, and Trot was 350±100 K. These results are discussed using different models for laser-induced thermal desorption from surfaces.

  2. Femtosecond laser pulse induced desorption: A molecular dynamics simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lončarić, Ivor, E-mail: ivor.loncaric@gmail.com [Centro de Física de Materiales CFM/MPC (CSIC-UPV/EHU), P. Manuel de Lardizabal 5, 20018 San Sebastián (Spain); Alducin, Maite [Centro de Física de Materiales CFM/MPC (CSIC-UPV/EHU), P. Manuel de Lardizabal 5, 20018 San Sebastián (Spain); Donostia International Physics Center DIPC, P. Manuel de Lardizabal 4, 20018 San Sebastián (Spain); Saalfrank, Peter [Institut für Chemie, Universität Potsdam, Karl-Liebknecht-Strasse 24-25, D-14476 Potsdam (Germany); Donostia International Physics Center DIPC, P. Manuel de Lardizabal 4, 20018 San Sebastián (Spain); Juaristi, J. Iñaki [Departamento de Física de Materiales, Facultad de Químicas, Universidad del País Vasco (UPV/EHU), Apartado 1072, 20080 San Sebastián (Spain); Centro de Física de Materiales CFM/MPC (CSIC-UPV/EHU), P. Manuel de Lardizabal 5, 20018 San Sebastián (Spain); Donostia International Physics Center DIPC, P. Manuel de Lardizabal 4, 20018 San Sebastián (Spain)

    2016-09-01

    In recent simulations of femtosecond laser induced desorption of molecular oxygen from the Ag(110) surface, it has been shown that depending on the properties (depth and electronic environment) of the well in which O{sub 2} is adsorbed, the desorption can be either induced dominantly by hot electrons or via excitations of phonons. In this work we explore whether the ratios between the desorption yields from different adsorption wells can be tuned by changing initial surface temperature and laser pulse properties. We show that the initial surface temperature is an important parameter, and that by using low initial surface temperatures the electronically mediated process can be favored. In contrast, laser properties seem to have only a modest influence on the results.

  3. Thermal desorption from surfaces with laser-induced defects

    Energy Technology Data Exchange (ETDEWEB)

    Szabelski, Pawel; Panczyk, Tomasz; Rudzinski, Wladyslaw

    2002-12-30

    Monte Carlo simulation method was used to mimic surface damage development caused by short laser pulses. The influence of pulsed laser irradiation on the creation of defect concentration was examined in the case of a model surface. In particular, the dependence of the intact surface area on a number of laser scans was studied and compared with the experimental results obtained for Rh(1 1 1) crystal face. Changes in the adsorptivoperties of the surface produced by laser irradiation are explained with the help of a simple geometric model connecting the laser intensity and the disordered area generated by a single laser shot. It was demonstrated that exponential decay of the Low Energy Electron Diffraction (LEED) signal with the number of laser scans, which is observed experimentally, may result directly from the overlapping of the laser spots created on the surface. This effect becomes enhanced when the laser intensity, hence the spot size, increases. The importance of laser-induced defects in the kinetics of catalytic/separation processes was examined in the case of temperature programmed desorption (TPD) spectra from surfaces subjected to a different number of laser shots. The spectra were simulated by employing the Monte Carlo method as well as by application of the absolute rate theory (ART) coupled with the mean field approximation. The results obtained with both methods were in a good agreement even when weak lateral interactions in the adsorbed phase were allowed.

  4. Laser-induced acoustic desorption (LIAD) mass spectrometry.

    Science.gov (United States)

    Dow, Alex M; Wittrig, Ashley R; Kenttämaa, Hilkka I

    2012-01-01

    Large thermally labile molecules were not amenable to mass spectrometric analysis until the development of atmospheric pressure evaporation/ionization methods, such as electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI), since attempts to evaporate these molecules by heating induces degradation of the sample. While ESI and MALDI are relatively soft desorption/ionization techniques, they are both limited to preferential ionization of acidic and basic analytes. This limitation has been the driving force for the development of other soft desorption/ionization techniques. One such method employs laser-induced acoustic desorption (LIAD) to evaporate neutral sample molecules into mass spectrometers. LIAD utilizes acoustic waves generated by a laser pulse in a thin metal foil. The acoustic waves travel through the foil and cause desorption of neutral molecules that have been deposited on the opposite side of the foil. One of the advantages of LIAD is that it desorbs low-energy molecules that can be ionized by a variety of methods, thus allowing the analysis of large molecules that are not amenable to ESI and MALDI. This review covers the generation of acoustic waves in foils via a laser pulse, the parameters affecting the generation of acoustic waves, possible mechanisms for desorption of neutral molecules, as well as the various uses of LIAD by mass spectrometrists. The conditions used to generate acoustic or stress waves in solid materials consist of three regimes: thermal, ablative, and constrained. Each regime is discussed, in addition to the mechanisms that lead to the ablation of the metal from the foil and generation of acoustic waves for two of the regimes. Previously proposed desorption mechanisms for LIAD are presented along with the flaws associated with some of them. Various experimental parameters, such as the exact characteristics of the laser pulse and foil used, are discussed. The internal and kinetic energy of the neutral

  5. Study on impurity desorption induced by femtosecond pulse laser based on a stochastic process model

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    With the advantages on non-equilibrium heating and desorption induced by electronic transition, the femtosecond pulse laser introduces a new way for solving the problem of impurity pollution adsorbed on a solid thin film in micro-electro-mechanical systems (MEMS). A model based on stochastic processes was established for stimulated desorption induced by the femtosecond pulse laser to interpret the interaction of the optically excited hot electrons with the adsorbed molecules in a metal substrate. Numerical simulation results reveal a time-dependent desorption probability of adsorbed molecules and indicate that how key parameters of femtosecond pulse laser, such as incident laser energy flux, pulse duration, and wavelength of pulse, have a great effect on the desorption probability.

  6. Laser desorption ionization and peptide sequencing on laser induced silicon microcolumn arrays

    Science.gov (United States)

    Vertes, Akos [Reston, VA; Chen, Yong [San Diego, CA

    2011-12-27

    The present invention provides a method of producing a laser-patterned silicon surface, especially silicon wafers for use in laser desorption ionization (LDI-MS) (including MALDI-MS and SELDI-MS), devices containing the same, and methods of testing samples employing the same. The surface is prepared by subjecting a silicon substrate to multiple laser shots from a high-power picosecond or femtosecond laser while in a processing environment, e.g., underwater, and generates a remarkable homogenous microcolumn array capable of providing an improved substrate for LDI-MS.

  7. Laser-Induced Acoustic Desorption Atmospheric Pressure Photoionization via VUV-Generating Microplasmas.

    Science.gov (United States)

    Benham, Kevin; Hodyss, Robert; Fernández, Facundo M; Orlando, Thomas M

    2016-11-01

    We demonstrate the first application of laser-induced acoustic desorption (LIAD) and atmospheric pressure photoionization (APPI) as a mass spectrometric method for detecting low-polarity organics. This was accomplished using a Lyman-α (10.2 eV) photon generating microhollow cathode discharge (MHCD) microplasma photon source in conjunction with the addition of a gas-phase molecular dopant. This combination provided a soft desorption and a relatively soft ionization technique. Selected compounds analyzed include α-tocopherol, perylene, cholesterol, phenanthrene, phylloquinone, and squalene. Detectable surface concentrations as low as a few pmol per spot sampled were achievable using test molecules. The combination of LIAD and APPI provided a soft desorption and ionization technique that can allow detection of labile, low-polarity, structurally complex molecules over a wide mass range with minimal fragmentation. Graphical Abstract ᅟ.

  8. Laser-Induced Acoustic Desorption Atmospheric Pressure Photoionization via VUV-Generating Microplasmas

    Science.gov (United States)

    Benham, Kevin; Hodyss, Robert; Fernández, Facundo M.; Orlando, Thomas M.

    2016-11-01

    We demonstrate the first application of laser-induced acoustic desorption (LIAD) and atmospheric pressure photoionization (APPI) as a mass spectrometric method for detecting low-polarity organics. This was accomplished using a Lyman-α (10.2 eV) photon generating microhollow cathode discharge (MHCD) microplasma photon source in conjunction with the addition of a gas-phase molecular dopant. This combination provided a soft desorption and a relatively soft ionization technique. Selected compounds analyzed include α-tocopherol, perylene, cholesterol, phenanthrene, phylloquinone, and squalene. Detectable surface concentrations as low as a few pmol per spot sampled were achievable using test molecules. The combination of LIAD and APPI provided a soft desorption and ionization technique that can allow detection of labile, low-polarity, structurally complex molecules over a wide mass range with minimal fragmentation.

  9. Theoretical Study of Pulsed-Laser-Induced Resonant Desorption.

    Science.gov (United States)

    1986-11-01

    laser the energy flow in the steady state is constant in time . Per unit of time it is given by,2 d- - & L Ire CW1 ( P () Pe ) " (4.4) dt r2 + 262 CW...1 - 2Pe(eq)] 2 + a cw (6.6) which is constant in time . The energy flow into the substrate is given by, dE2 cw A 2- 0 1 - 2Pe(-)1. (6.7) t F Jq, 14

  10. Fabrication of chemical templates via selective laser-induced desorption of hexadecanethiol self-assembled monolayers

    Science.gov (United States)

    Schröter, Anja; Mathieu, Mareike; Franzka, Steffen; Feydt, Jürgen; Irsen, Stephan; Hartmann, Nils

    2013-08-01

    A nonlinear photothermal laser patterning technique for rapid fabrication of chemical templates is demonstrated. Hexadecanethiol monolayers on Au-coated Si substrates are processed at λ = 532 nm, a 1/e2 spot diameter of d=2.8 μm and ambient conditions. Local laser irradiation at high laser powers and short irradiation times in the micro-/millisecond range induces desorption of thiol molecules. The laser-depleted areas are backfilled with mercaptohexadecanoic acid in order to build up chemical templates. Atomic force microscopy, scanning electron microscopy and scanning Auger electron spectroscopy are used for characterization of these templates. In agreement with a selective laser process, the results indicate the formation of flat chemical patterns with well-defined boundaries. Complementary condensation experiments demonstrate the functionality of the patterns as hydrophilic/hydrophobic templates. In particular, upon decreasing the temperature below the dew point, selective formation of water droplets on the backfilled areas is observed.

  11. Fabrication of chemical templates via selective laser-induced desorption of hexadecanethiol self-assembled monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Schröter, Anja; Mathieu, Mareike; Franzka, Steffen [Fakultät für Chemie, Universität Duisburg-Essen, 45117 Essen (Germany); CENIDE – Center for Nanointegration Duisburg-Essen, 47048 Duisburg (Germany); Feydt, Jürgen; Irsen, Stephan [caesar – Center of Advanced European Studies and Research, 53175 Bonn (Germany); Hartmann, Nils, E-mail: nils.hartmann@uni-due.de [Fakultät für Chemie, Universität Duisburg-Essen, 45117 Essen (Germany); CENIDE – Center for Nanointegration Duisburg-Essen, 47048 Duisburg (Germany)

    2013-08-01

    A nonlinear photothermal laser patterning technique for rapid fabrication of chemical templates is demonstrated. Hexadecanethiol monolayers on Au-coated Si substrates are processed at λ = 532 nm, a 1/e{sup 2} spot diameter of d{sub 1/e{sup 2}}=2.8μm and ambient conditions. Local laser irradiation at high laser powers and short irradiation times in the micro-/millisecond range induces desorption of thiol molecules. The laser-depleted areas are backfilled with mercaptohexadecanoic acid in order to build up chemical templates. Atomic force microscopy, scanning electron microscopy and scanning Auger electron spectroscopy are used for characterization of these templates. In agreement with a selective laser process, the results indicate the formation of flat chemical patterns with well-defined boundaries. Complementary condensation experiments demonstrate the functionality of the patterns as hydrophilic/hydrophobic templates. In particular, upon decreasing the temperature below the dew point, selective formation of water droplets on the backfilled areas is observed.

  12. Quantum dynamics of STM and laser induced desorption of atoms and molecules from surfaces

    CERN Document Server

    Boendgen, G

    2001-01-01

    The manipulation of atoms and molecules at solid surfaces by electronic excitations with electrons (or holes) emitted from the tip of a scanning tunneling microscope (STM) or with laser radiation is both of applied and fundamental interest, e.g. for micro- and nanostructuring of materials, the clarification of elementary (catalytic) reaction mechanisms and for the question of how to treat the quantum dynamics of a laser or STM driven 'system' (the adsorbate) in contact with a dissipative (energy-withdrawing) 'bath' (the substrate). Desorption induced by electronic transitions (DIET) and its variant DIMET (M = multiple) are among the simplest possible 'reactions' of adsorbate-surface systems; usually involving extremely short-lived electronically excited intermediates. In this thesis, the ultra-short dynamics of directly (localised to the adsorbate-substrate complex) and indirectly (i.e., through the substrate) stimulated DIET and DIMET processes was studied for Si(100)-(2x1):H(D) and Pt(111):NO. Isotope effec...

  13. Laser-induced acoustic desorption coupled with a linear quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Habicht, Steven C; Amundson, Lucas M; Duan, Penggao; Vinueza, Nelson R; Kenttämaa, Hilkka I

    2010-01-15

    In recent years, laser-induced acoustic desorption (LIAD) coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been demonstrated to provide a valuable technique for the analysis of a wide variety of nonvolatile, thermally labile compounds, including analytes that could not previously be analyzed by mass spectrometry. Although FT-ICR instruments are very powerful, they are also large and expensive and, hence, mainly used as research instruments. In contrast, linear quadrupole ion trap (LQIT) mass spectrometers are common due to several qualities that make these instruments attractive for both academic and industrial settings, such as high sensitivity, large dynamic range, and experimental versatility. Further, the relatively small size of the instruments, comparatively low cost, and the lack of a magnetic field provide some distinct advantages over FT-ICR instruments. Hence, we have coupled the LIAD technique with a commercial LQIT, the Thermo Fischer Scientific LTQ mass spectrometer. The LQIT was modified for a LIAD probe by outfitting the removable back plate of the instrument with a 6 in. ConFlat flange (CFF) port, gate valve, and sample lock. Reagent ions were created using the LQIT's atmospheric pressure ionization source and trapped in the mass analyzer for up to 10 s to allow chemical ionization reactions with the neutral molecules desorbed via LIAD. These initial experiments focused on demonstrating the feasibility of performing LIAD in the LQIT. Hence, the results are compared to those obtained using an FT-ICR mass spectrometer. Despite the lower efficiency in the transfer of desorbed neutral molecules into the ion trap, and the smaller maximum number of available laser pulses, the intrinsically higher sensitivity of the LQIT resulted in a higher sensitivity relative to the FT-ICR.

  14. Laser-induced desorption of overlayer films off a heated metal substrate

    Science.gov (United States)

    Gu, Xiang; Urbassek, Herbert M.

    2007-02-01

    The temperature-induced desorption of adsorbed overlayer films with thicknesses between 4 and 200 ML off a suddenly heated metal substrate is studied using molecular-dynamics simulation. We observe that the rapid heating vaporizes the surface-near part of the overlayer film. The initial heating-induced thermoelastic pressure and the vapor pressure in the vapor film drive the remaining film as a large relatively cold cluster away from the surface. In our simulations, the material present in the developing vapor film amounts to roughly 2 ML and is quite independent of the overlayer film thickness. For cluster thicknesses beyond 40 ML, the desorption time increases only little with film thickness, while the resulting cluster velocity decreases only slightly.

  15. Effect of heat treatment on UV-laser-induced positive ion desorption in CaHPO4.2H2O

    Science.gov (United States)

    Kawaguchi, Y.; Dawes, M. L.; Langford, S. C.; Dickinson, J. T.

    We have investigated KrF excimer-laser-induced positive ion desorption from single-crystal brushite (CaHPO4.2H2O), a model biomineral containing water, and we show the effect of heat treatment on ion desorption. Time-of-flight peaks of Ca+ desorption from the heated-cleaved surface are similar to those from as-cleaved ones, but the ion intensity is 2 to 4 orders of magnitude larger. In addition to Ca+, desorption of CaO+, PO+, and P+ from the heated surface is also strongly enhanced. The heated-cleaved surface shows rough, platelet-like fine structures due to recrystallization. Surface defects created during recrystallization strongly couple with the 5 eV photons and dramatically enhance ion desorption.

  16. Optical laser-induced CO desorption from Ru(0001) monitored with a free-electron X-ray laser

    DEFF Research Database (Denmark)

    Öberg, H.; Gladh, J.; Dell'Angela, M.

    2015-01-01

    We present density functional theory modeling of time-resolved optical pump/X-ray spectroscopic probe data of CO desorption from Ru(0001). The BEEF van der Waals functional predicts a weakly bound state as a precursor to desorption. The optical pump leads to a near-instantaneous (b100 fs) increas...

  17. Atmospheric pressure laser-induced acoustic desorption chemical ionization Fourier transform ion cyclotron resonance mass spectrometry for the analysis of complex mixtures.

    Science.gov (United States)

    Nyadong, Leonard; McKenna, Amy M; Hendrickson, Christopher L; Rodgers, Ryan P; Marshall, Alan G

    2011-03-01

    We present a novel nonresonant laser-based matrix-free atmospheric pressure ionization technique, atmospheric pressure laser-induced acoustic desorption chemical ionization (AP/LIAD-CI). The technique decouples analyte desorption from subsequent ionization by reagent ions generated from a corona discharge initiated in ambient air or in the presence of vaporized toluene as a CI dopant at room temperature. Analyte desorption is initiated by a shock wave induced in a titanium foil coated with electrosprayed sample, irradiated from the rear side by high-energy laser pulses. The technique enables facile and independent optimization of the analyte desorption, ionization, and sampling events, for coupling to any mass analyzer with an AP interface. Moreover, the generated analyte ions are efficiently thermalized by collisions with atmospheric gases, thereby reducing fragmentation. We have coupled AP/LIAD-CI to ultrahigh-resolution FT-ICR MS to generate predominantly [M + H](+) or M(+•) ions to resolve and identify thousands of elemental compositions from organic mixtures as complex as petroleum crude oil distillates. Finally, we have optimized the AP/LIAD CI process and investigated ionization mechanisms by systematic variation of placement of the sample, placement of the corona discharge needle, discharge current, gas flow rate, and inclusion of toluene as a dopant.

  18. Infrared laser desorption/ionization on silicon.

    Science.gov (United States)

    Bhattacharya, Sucharita H; Raiford, Timothy J; Murray, Kermit K

    2002-05-01

    Laser desorption/ionization from a single-crystal silicon surface was performed using a laser operating in the 3-microm region of the mid-infrared. Analyte molecules up to 6 kDa were ionized with no added matrix. As with ultraviolet desorption/ionization from porous silicon (DIOS), IR laser desorption from silicon does not produce matrix ions that can interfere with analysis of low-mass analytes. However, in contrast to UV DIOS, silicon porosity or roughness is not required for ionization using an IR laser. Mass spectra were obtained in the wavelength range between 2.8 and 3.5 microm, which is consistent with energy absorption by a hydrogen-bonded OH group. A mechanism based on desorption of adsorbed solvent molecules is postulated.

  19. Laser-induced electron transfer desorption/ionization of metal complexes on TiO2 films

    Science.gov (United States)

    Grechnikov, A. A.; Georgieva, V.; Borodkov, A. S.; Nikiforov, S. M.; Raicheva, Z.; Lazarov, J.; Donkov, N.

    2014-12-01

    Thin titanium dioxide (TiO2) films were studied as ion emitters for the laser-induced electron transfer desorption/ionization (LETDI) of metal complexes with organic reagents. The TiO2 films (350 nm thick) were deposited on the silicon substrates by e-beam evaporation of TiO2 powder. Copper complex with phthalocyanine, rhenium complex with thiocarbanilide and platinum complex with 8-quinolinethiol were studied as the test analytes. Reflectron time-of- flight mass spectrometer with the rotating ball interface was used for analysis. The analytes were applied on the surface of TiO2 film using an electrospray deposition. All tested compounds are detected as the radical molecular ions with no fragmentation. It is found, that TiO2 films are very stable and show good sensitivity in examined range of the analyte concentrations. The limits of detection of studied complexes were at the subfemtomole range, and the relative standard deviation was less than 10%.

  20. UV laser induced desorption of CsI and RbI ion clusters

    Science.gov (United States)

    Fernández-Lima, F. A.; Ponciano, C. R.; Filho, H. D. Fonseca; Pedrero, E.; Chaer Nascimento, M. A.; da Silveira, E. F.

    2006-09-01

    Experimental results of laser sputtering of cesium and rubidium iodide secondary ions are presented. A TOF mass spectrometer, operating in linear mode, continuous extraction for positive or negative ions, was used for the analysis of (CsI) nCs +, (CsI) nI -, (RbI) nRb + and (RbI) nI - ion emission as a function of the laser irradiance. Experimental data show that the cluster ion emission yields decrease exponentially with n, for all the laser irradiances applied. Theoretical analysis of the clusters structure was performed using density functional theory at the B3LYP/LACV3P level, for the positive and negative cluster series. A quasi-equilibrium evolution of the clusters is proposed to extract a parameter characteristic of the cluster recombination process: the effective temperature. The hypothesis of the atomic species' recombination (during the expansion of a high density highly ionized cloud) leading to cluster formation is confirmed to some extent in a second set of experiments: the UV laser ablation of a mixed and non-mixed cesium iodide and potassium bromide targets. These experiments show that the emission yields contain contributions from both the recombination process and from the sample stoichiometry, even for high laser irradiances.

  1. SPS Ion Induced Desorption Experiment

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    This experiment will give a study about the induced desorption from heavy ion (Indium ion run from week 45 in SPS T4-H8 area) impacting LHC type graphite collimator. 4 different samples are located in the 4 chambers 90° one to each other: pure graphite, graphite with copper coating, graphite with NEG coating, 316LN stainless steal (reference).

  2. Laser desorption of NO from a thick C 60 film

    Science.gov (United States)

    Hoger, T.; Marzok, C.; Jongma, R. T.; Zacharias, H.

    2006-09-01

    The desorption of NO molecules from a thick C 60 film is reported. A thermal desorption spectrum indicates two adsorption sites with binding energies of Eb = 0.30 eV and 0.55 eV. For laser desorption the fullerene surface is exposed to NO and excited by 7 ns UV laser pulses. Desorbing NO molecules are recorded state selectively as well as time resolved. The time-of-flight measurement indicates three different desorption pathways. A fast channel shows rovibronic temperatures of Trot( v″ = 0) = 370 K, Trot( v″ = 1) = 390 K and Tvib = 610 K as well as strong rotational-translational coupling. The desorption yield for the fast channel increases linearly with pulse energy with a desorption cross section of σ = (5.1 ± 0.9) × 10 -17 cm 2. Dominating the signal for small J″ values is a slow channel with low rotational and translational temperatures of about 110 K. We assign this peak to a laser-induced thermal desorption. For large pump-probe delays the data deviate from the Maxwellian flux distribution and a third channel appears with extremely late arrival times.

  3. Quantum theory of laser-stimulated desorption

    Science.gov (United States)

    Slutsky, M. S.; George, T. F.

    1978-01-01

    A quantum theory of laser-stimulated desorption (LSDE) is presented and critically analyzed. It is shown how LSDE depends on laser-pulse characteristics and surface-lattice dynamics. Predictions of the theory for a Debye model of the lattice dynamics are compared to recent experimental results.

  4. Substrate-Enhanced Micro Laser Desorption Ionization Mass Spectrometry Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aerodyne Research, Inc. and the University of Massachusetts at Amherst will collaborate to develop laser desorption ionization (LDI) mass spectrometric analysis of...

  5. The laser desorption/laser ionization mass spectra of some methylated xanthines and the laser desorption of caffeine and theophylline from thin layer chromatography plates

    Science.gov (United States)

    Rogers, Kevin; Milnes, John; Gormally, John

    1993-02-01

    Laser desorption/laser ionization time-of-flight mass spectra of caffeine, theophylline, theobromine and xanthine are reported. These mass spectra are compared with published spectra obtained using electron impact ionization. Mass spectra of caffeine and theophylline obtained by IR laser desorption from thin layer chromatography plates are also described. The laser desorption of materials from thin layer chromatography plates is discussed.

  6. Site Specificity in Femtosecond Laser Desorption of Neutral H Atoms from Graphite(0001)

    DEFF Research Database (Denmark)

    Frigge, R.; Hoger, T.; Siemer, B.;

    2010-01-01

    Femtosecond laser excitation and density functional theory reveal site and vibrational state specificity in neutral atomic hydrogen desorption from graphite induced by multiple electronic transitions. Multimodal velocity distributions witness the participation of ortho and para pair states...... of chemisorbed hydrogen in the desorption process. Very slow velocities of 700 and 400  ms-1 for H and D atoms are associated with the desorption out of the highest vibrational state of a barrierless potential....

  7. Micro- and nanopatterning of functional organic monolayers on oxide-free silicon by laser-induced photothermal desorption.

    Science.gov (United States)

    Scheres, Luc; Klingebiel, Benjamin; ter Maat, Jurjen; Giesbers, Marcel; de Jong, Hans; Hartmann, Nils; Zuilhof, Han

    2010-09-06

    The photothermal laser patterning of functional organic monolayers, prepared on oxide-free hydrogen-terminated silicon, and subsequent backfilling of the laser-written lines with a second organic monolayer that differs in its terminal functionality, is described. Since the thermal monolayer decomposition process is highly nonlinear in the applied laser power density, subwavelength patterning of the organic monolayers is feasible. After photothermal laser patterning of hexadecenyl monolayers, the lines freed up by the laser are backfilled with functional acid fluoride monolayers. Coupling of cysteamine to the acid fluoride groups and subsequent attachment of Au nanoparticles allows easy characterization of the functional lines by atomic force microscopy (AFM) and scanning electron microscopy (SEM). Depending on the laser power and writing speed, functional lines with widths between 1.1 μm and 250 nm can be created. In addition, trifluoroethyl-terminated (TFE) monolayers are also patterned. Subsequently, the decomposed lines are backfilled with a nonfunctional hexadecenyl monolayer, the TFE stripes are converted into thiol stripes, and then finally covered with Au nanoparticles. By reducing the lateral distance between the laser lines, Au-nanoparticle stripes with widths close to 100 nm are obtained. Finally, in view of the great potential of this type of monolayer in the field of biosensing, the ease of fabricating biofunctional patterns is demonstrated by covalent binding of fluorescently labeled oligo-DNA to acid-fluoride-backfilled laser lines, which--as shown by fluorescence microscopy--is accessible for hybridization.

  8. Characterization of nonpolar lipids and steroids by using laser-induced acoustic desorption/chemical ionization, atmospheric pressure chemical ionization, and electrospray ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Z; Daiya, S; Kenttämaa, Hilkka I

    Laser-induced acoustic desorption (LIAD) combined with ClMn(H{sub 2}O){sup +} chemical ionization (CI) was tested for the analysis of nonpolar lipids and selected steroids in a Fourier-transform ion cyclotron resonance mass spectrometer (FT-ICR). The nonpolar lipids studied, cholesterol, 5α-cholestane, cholesta-3,5-diene, squalene, and β-carotene, were found to solely form the desired water replacement product (adduct-H{sub 2}O) upon reaction with the ClMn(H{sub 2}O){sup +} ions. The steroids, androsterone, dehydroepiandrosterone (DHEA), estrone, estradiol, and estriol, also form abundant adduct-H{sub 2}O ions, but less abundant adduct-2H{sub 2}O ions were also observed. Neither (+)APCI nor (+)ESI can ionize the saturated hydrocarbon lipid, cholestane. APCI successfully ionizes the unsaturated hydrocarbon lipids to form exclusively the intact protonated analytes. However, it causes extensive fragmentation for cholesterol and the steroids. The worst case is cholesterol that does not produce any stable protonated molecules. On the other hand, ESI cannot ionize any of the hydrocarbon analytes, saturated or unsaturated. However, ESI can be used to protonate the oxygen-containing analytes with substantially less fragmentation than for APCI in all cases except for cholesterol and estrone. In conclusion, LIAD/ClMn(H{sub 2}O){sup +} chemical ionization is superior over APCI and ESI for the mass spectrometric characterization of underivatized nonpolar lipids and steroids.

  9. Laser Desorption Mass Spectrometry. II. Applications to Structural Analysis.

    Science.gov (United States)

    1982-02-02

    was unexpected, was the quaternary amine Safranin -O. Ions corresponding to (M-HC)- at m/z 313 dominate the negative ion mass spectrum. Two classes of...and cluster species were observed. The positive ion LD mass spectrum of safranin -O, shown in Figure 6, is tvnical of LD results for salts. The...Figure 6. Laser Desorption Positive-ion Spectrum of Safranin 0. Figure 7. Laser Desorntion Mass Spectra of Doubly Charged Organic Salts Top - N,N

  10. Laser desorption lamp ionization source for ion trap mass spectrometry.

    Science.gov (United States)

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds.

  11. Investigations into ultraviolet matrix-assisted laser desorption

    Energy Technology Data Exchange (ETDEWEB)

    Heise, Theodore W. [Iowa State Univ., Ames, IA (United States)

    1993-07-01

    Matrix-assisted laser desorption (MALD) is a technique for converting large biomolecules into gas phase ions. Some characteristics of the commonly used uv matrices are determined. Solubilities in methanol range from 0.1 to 0.5 M. Solid phase absorption spectra are found to be similar to solution, but slightly red-shifted. Acoustic and quartz crystal microbalance signals are investigated as possible means of uv-MALD quantitation. Evidence for the existence of desorption thresholds is presented. Threshold values are determined to be in the range of 2 to 3 MW/cm2. A transient imaging technique based on laser-excited fluorescence for monitoring MALD plumes is described. Sensitivity is well within the levels required for studying matrix-assisted laser desorption, where analyte concentrations are significantly lower than those in conventional laser desorption. Results showing the effect of film morphology, particularly film thickness, on plume dynamics are presented. In particular, MALD plumes from thicker films tend to exhibit higher axial velocities. Fluorescent labeling of protein and of DNA is used to allow imaging of their uv-MALD generated plumes. Integrated concentrations are available with respect to time, making it possible to assess the rate of fragmentation. The spatial and temporal distributions are important for the design of secondary ionization schemes to enhance ion yields and for the optimization of ion collection in time-of-flight MS instruments to maximize resolution. Such information could also provide insight into whether ionization is closely associated with the desorption step or whether it is a result of subsequent collisions with the matrix gas (e.g., proton transfer). Although the present study involves plumes in a normal atmosphere, adaptation to measurements in vacuum (e.g., inside a mass spectrometer) should be straightforward.

  12. Layer-by-layer thin film of reduced graphene oxide and gold nanoparticles as an effective sample plate in laser-induced desorption/ionization mass spectrometry.

    Science.gov (United States)

    Kuo, Tsung-Rong; Wang, Di-Yan; Chiu, Yu-Chen; Yeh, Yun-Chieh; Chen, Wei-Ting; Chen, Ching-Hui; Chen, Chun-Wei; Chang, Huan-Cheng; Hu, Cho-Chun; Chen, Chia-Chun

    2014-01-27

    This work demonstrated a simple platform for rapid and effective surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF MS) measurements based on the layer structure of reduced graphene oxide (rGO) and gold nanoparticles. A multi-layer thin film was fabricated by alternate layer-by-layer depositions of rGO and gold nanoparticles (LBL rGO/AuNP). The flat and clean two-dimensional film was served as the sample plate and also functioned as the matrix in SALDI-TOF MS. By simply one-step deposition of analytes onto the LBL rGO/AuNP sample plate, the MS measurements of various homogeneous samples were ready to execute. The optimization of MS signal was reached by the variation of the layer numbers of rGO and gold nanoparticles. Also, the small molecules including amino acids, carbohydrates and peptides were successfully analyzed in SALDI-TOF MS using the LBL rGO/AuNP sample plate. The results showed that the signal intensity, S N(-1) ratio and reproducibility of SALDI-TOF spectra have been significantly improved in comparison to the uses of gold nanoparticles or α-cyano-4-hydroxy-cinnamic acid (CHCA) as the assisted matrixes. Taking the advantages of the unique properties of rGO and gold nanoparticles, the ready-to-use MS sample plate, which could absorb and dissipate laser energy to analytes quite efficiently and homogeneously, has shown great commercial potentials for MS applications.

  13. Laser Desorption Postionization for Imaging MS of Biological Material

    OpenAIRE

    Akhmetov, Artem; Moore, Jerry F.; Gasper, Gerald L.; Koin, Peter J.; Hanley, Luke

    2010-01-01

    Vacuum ultraviolet single photon ionization (VUV SPI) is a soft ionization technique that has the potential to address many of the limitations of MALDI for imaging MS. Laser desorption postionization (LDPI) employs VUV SPI for postionization and is experimentally analogous to a MALDI instrument with the addition of a pulsed VUV light source. This review discusses progress in LDPI-MS over the last decade, with an emphasis on imaging MS of bacterial biofilms, analytes whose high salt environmen...

  14. 2nd International Workshop on Desorption Induced by Electronic Transitions

    CERN Document Server

    Menzel, Dietrich

    1985-01-01

    The second workshop on Desorption Induced by Electronic Transitions (DIET II) took place October 15-17, 1984, in SchloB Elmau, Bavaria. DIET II, fol­ lowing the great success of DIET I (edited by N. H. Tolk, M. M. Traum, J. C. Tully, T. E. Madey and published in Springer Ser. Chem. Phys. , Vol. 24), again brought together over 60 workers in this exciting field. The "hard co­ re of experts" was essentially the same as in DIET I but the general overlap of participants between the two meetings was small. While DIET I had the function of an exposition of the status of the field DIET II focussed more on new developments. The main emphasis was again on the microscopic under­ standing of DIET but a number of side aspects and the application of DIET ideas to other fields such as sputtering, laser-induced desorption, fractu­ re, erosion, etc. were considered, too. New mechanisms and new refined expe­ rimental techniques were proposed and discussed at the meeting critically but with great enthusiasm. In addition t...

  15. Desorption Dynamics, Internal Energies and Imaging of Organic Molecules from Surfaces with Laser Desorption and Vacuum Ultraviolet (VUV) Photoionization

    Energy Technology Data Exchange (ETDEWEB)

    Kostko, Oleg; Takahashi, Lynelle K.; Ahmed, Musahid

    2011-04-05

    There is enormous interest in visualizing the chemical composition of organic material that comprises our world. A convenient method to obtain molecular information with high spatial resolution is imaging mass spectrometry. However, the internal energy deposited within molecules upon transfer to the gas phase from a surface can lead to increased fragmentation and to complications in analysis of mass spectra. Here it is shown that in laser desorption with postionization by tunable vacuum ultraviolet (VUV) radiation, the internal energy gained during laser desorption leads to minimal fragmentation of DNA bases. The internal temperature of laser-desorbed triacontane molecules approaches 670 K, whereas the internal temperature of thymine is 800 K. A synchrotron-based VUV postionization technique for determining translational temperatures reveals that biomolecules have translational temperatures in the range of 216-346 K. The observed low translational temperatures, as well as their decrease with increased desorption laser power is explained by collisional cooling. An example of imaging mass spectrometry on an organic polymer, using laser desorption VUV postionization shows 5 mu m feature details while using a 30 mu m laser spot size and 7 ns duration. Applications of laser desorption postionization to the analysis of cellulose, lignin and humic acids are briefly discussed.

  16. Laser desorption postionization for imaging MS of biological material.

    Science.gov (United States)

    Akhmetov, Artem; Moore, Jerry F; Gasper, Gerald L; Koin, Peter J; Hanley, Luke

    2010-02-01

    Vacuum ultraviolet single photon ionization (VUV SPI) is a soft ionization technique that has the potential to address many of the limitations of matrix-assisted laser desorption/ionization (MALDI) for imaging MS. Laser desorption postionization (LDPI) uses VUV SPI for postionization and is experimentally analogous to a MALDI instrument with the addition of a pulsed VUV light source. This review discusses progress in LDPI-MS over the last decade, with an emphasis on imaging MS of bacterial biofilms, analytes whose high salt environment make them particularly resistant to imaging by MALDI-MS. This review first considers fundamental aspects of VUV SPI including ionization mechanisms, cross sections, quantum yields of ionization, dissociation and potential mass limits. The most common sources of pulsed VUV radiation are then described along with a newly constructed LDPI-MS instrument with imaging capabilities. Next, the detection and imaging of small molecules within intact biofilms is demonstrated by LDPI-MS using 7.87 eV (157.6 nm) VUV photons from a molecular fluorine excimer laser, followed by the use of aromatic tags for detection of selected species within the biofilm. The final section considers the future prospects for imaging intact biological samples by LDPI-MS. Copyright 2010 John Wiley & Sons, Ltd.

  17. Influence of fs-laser desorption on target normal sheath accelerated ions

    Directory of Open Access Journals (Sweden)

    G. Hoffmeister

    2013-04-01

    Full Text Available We report on the effects of fs-laser desorption on the ion acceleration induced by the target normal sheath acceleration (TNSA mechanism. The experiment was performed at the Lawrence Livermore National Laboratory (LLNL using the 100 TW Callisto laser of the Jupiter Laser Facility (JLF. Thin metal foils (Au, Cu, and Al with thicknesses ranging from 10 to 20  μm were irradiated by a variable number of low intensity (∼10^{12}  W/cm^{2} laser pulses, the last one arriving 100 ms before the main pulse. With these short pulses water vapor and hydrocarbon contaminations could stepwise be removed from the target surface. Substantial modifications of the TNSA-ion energy spectra were observed such as diminished proton energy and intensity, the absence of low-charged ion states, increased particle numbers for C^{4+} and O^{6+} ions in the higher energetic part of their particle spectra as well as the acceleration of target ions. The controlled application of fs-laser desorption on the laser-ion acceleration thus strongly influences the ion spectra and offers the possibility of selecting a targeted range of ion species for the acceleration to higher energies due to the systematic removal of contamination layers.

  18. Laser desorption VUV postionization MS imaging of a cocultured biofilm.

    Science.gov (United States)

    Bhardwaj, Chhavi; Moore, Jerry F; Cui, Yang; Gasper, Gerald L; Bernstein, Hans C; Carlson, Ross P; Hanley, Luke

    2013-09-01

    Laser desorption postionization mass spectrometry (LDPI-MS) imaging is demonstrated with a 10.5 eV photon energy source for analysis and imaging of small endogenous molecules within intact biofilms. Biofilm consortia comprised of a synthetic Escherichia coli K12 coculture engineered for syntrophic metabolite exchange are grown on membranes and then used to test LDPI-MS analysis and imaging. Both E. coli strains displayed many similar peaks in LDPI-MS up to m/z 650, although some observed differences in peak intensities were consistent with the appearance of byproducts preferentially expressed by one strain. The relatively low mass resolution and accuracy of this specific LDPI-MS instrument prevented definitive assignment of species to peaks, but strategies are discussed to overcome this shortcoming. The results are also discussed in terms of desorption and ionization issues related to the use of 10.5 eV single-photon ionization, with control experiments providing additional mechanistic information. Finally, 10.5 eV LDPI-MS was able to collect ion images from intact, electrically insulating biofilms at ~100 μm spatial resolution. Spatial resolution of ~20 μm was possible, although a relatively long acquisition time resulted from the 10 Hz repetition rate of the single-photon ionization source.

  19. Heavy-Ion-Induced Electronic Desorption of Gas from Metals

    CERN Document Server

    Molvik, A W; Mahner, E; Kireeff Covo, M; Bellachioma, M C; Bender, M; Bieniosek, F M; Hedlund, E; Krämer, A; Kwan, J; Malyshev, O B; Prost, L; Seidl, P A; Westenskow, G; Westerberg, L

    2007-01-01

    During heavy-ion operation in several particle accelerators worldwide, dynamic pressure rises of orders of magnitude were triggered by lost beam ions that bombarded the vacuum chamber walls. This ion-induced molecular desorption, observed at CERN, GSI, and BNL, can seriously limit the ion beam lifetime and intensity of the accelerator. From dedicated test stand experiments we have discovered that heavy-ion-induced gas desorption scales with the electronic energy loss (dEe/dx) of the ions slowing down in matter; but it varies only little with the ion impact angle, unlike electronic sputtering.

  20. Heavy-ion induced electronic desorption of gas from metals

    Energy Technology Data Exchange (ETDEWEB)

    Molvik, A W; Kollmus, H; Mahner, E; Covo, M K; Bellachioma, M C; Bender, M; Bieniosek, F M; Hedlund, E; Kramer, A; Kwan, J; Malyshev, O B; Prost, L; Seidl, P A; Westenskow, G; Westerberg, L

    2006-12-19

    During heavy ion operation in several particle accelerators world-wide, dynamic pressure rises of orders of magnitude were triggered by lost beam ions that bombarded the vacuum chamber walls. This ion-induced molecular desorption, observed at CERN, GSI, and BNL, can seriously limit the ion beam lifetime and intensity of the accelerator. From dedicated test stand experiments we have discovered that heavy-ion induced gas desorption scales with the electronic energy loss (dE{sub e}/d/dx) of the ions slowing down in matter; but it varies only little with the ion impact angle, unlike electronic sputtering.

  1. Gold ion beams induced desorption studies for Booster Nuclotron

    Science.gov (United States)

    Kuznetsov, A. B.; Tuzikov, A. V.; Philippov, A. V.

    2016-12-01

    Heavy ions induced pressure rise is one of the machine limits. The calculation results of the gold ion beam 197Au31+ losses due to residual gas interaction in view of desorption of adsorbed particles on the Booster Nuclotron vacuum chamber surface are discussed.

  2. Electronically driven adsorbate excitation mechanism in femtosecond-pulse laser desorption

    DEFF Research Database (Denmark)

    Brandbyge, Mads; Hedegård, Per; Heinz, T. F.

    1995-01-01

    Femtosecond-pulse laser desorption is a process in which desorption is driven by a subpicosecond temperature pulse of order 5000 K in the substrate-adsorbate electron system, whose energy is transferred into the adsorbate center-of-mass degrees of freedom by a direct coupling mechanism. We presen...

  3. Development of the positron-induced ion-desorption apparatus

    CERN Document Server

    Kanazawa, I

    2002-01-01

    The principle of the positron-induced ion-desorption, which is developed recently, and experimental apparatus are explained and study of desorption of positron-induced hydrogen ion from surface of Ni is reported as an example. The slow positron beam system in the positron-induced ion-desorption spectroscopy is consisted of two stages, moderator and transformation from magnetic transport type to electrostatic transport type. Positron is antiparticle of electron and localized both outside and monolayer of surface, which is special futures and used to analyze the surface. The number of emission positive charge particles from the clean Ni surface was changed by coil current at 1.9 keV and 2.9 keV incident positron energy. The number of re-emission positron at 1.9 keV was larger than at 2.9 keV. The number of emission positive charge particles from the clean Ni surface adsorbed monolayer hydrogen atom were decreased with coil current at 1.9 keV and 2.9 keV. The number of desorption hydrogen particle at 1.9 keV was...

  4. Ion intensity and thermal proton transfer in ultraviolet matrix-assisted laser desorption/ionization.

    Science.gov (United States)

    Lu, I-Chung; Lee, Chuping; Chen, Hui-Yuan; Lin, Hou-Yu; Hung, Sheng-Wei; Dyakov, Yuri A; Hsu, Kuo-Tung; Liao, Chih-Yu; Lee, Yin-Yu; Tseng, Chien-Ming; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-04-17

    The ionization mechanism of ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI) was investigated by measuring the total cation intensity (not including sodiated and potasiated ions) as a function of analyte concentration (arginine, histidine, and glycine) in a matrix of 2,4,6-trihydroxyacetophenone (THAP). The total ion intensity increased up to 55 times near the laser fluence threshold as the arginine concentration increased from 0% to 1%. The increases were small for histidine, and a minimal increase occurred for glycine. Time-resolved fluorescence intensity was employed to investigate how analytes affected the energy pooling of the matrix. No detectable energy pooling was observed for pure THAP and THAP/analyte mixtures. The results can be described by using a thermal proton transfer model, which suggested that thermally induced proton transfer is crucial in the primary ion generation in UV-MALDI.

  5. Quantitative analysis of biopolymers by matrix-assisted laser desorption

    Energy Technology Data Exchange (ETDEWEB)

    Tang, K.; Allman, S.L.; Jones, R.B.; Chen, C.H. (Oak Ridge National Lab., TN (United States))

    1993-08-01

    During the past few years, major efforts have been made to use mass spectrometry to measure biopolymers because of the great potential benefit to biological and medical research. Although the theoretical details of laser desorption and ionization mechanisms of MALDI are not yet fully understood, several models have been presented to explain the production of large biopolymer ions. In brief, it is very difficult to obtain reliable measurements of the absolute quantity of analytes by MALDI. If MALDI is going to become a routine analytical tool, it is obvious that quantitative measurement capability must be pursued. Oligonucleotides and protein samples used in this work were purchased from commercial sources. Nicotinic acid was used as matrix for both types of biopolymers. From this experiment, it is seen that it is difficult to obtain absolute quantitative measurements of biopolymers using MALDI. However, internal calibration with molecules having similar chemical properties can be used to resolve these difficulties. Chemical reactions between biopolymers must be avoided to prevent the destruction of the analyte materials. 10 refs., 8 figs.

  6. Thermal proton transfer reactions in ultraviolet matrix-assisted laser desorption/ionization.

    Science.gov (United States)

    Chu, Kuan Yu; Lee, Sheng; Tsai, Ming-Tsang; Lu, I-Chung; Dyakov, Yuri A; Lai, Yin Hung; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-03-01

    One of the reasons that thermally induced reactions are not considered a crucial mechanism in ultraviolet matrix-assisted laser desorption ionization (UV-MALDI) is the low ion-to-neutral ratios. Large ion-to-neutral ratios (10(-4)) have been used to justify the unimportance of thermally induced reactions in UV-MALDI. Recent experimental measurements have shown that the upper limit of the total ion-to-neutral ratio is approximately 10(-7) at a high laser fluence and less than 10(-7) at a low laser fluence. Therefore, reexamining the possible contributions of thermally induced reactions in MALDI may be worthwhile. In this study, the concept of polar fluid was employed to explain the generation of primary ions in MALDI. A simple model, namely thermal proton transfer, was used to estimate the ion-to-neutral ratios in MALDI. We demonstrated that the theoretical calculations of ion-to-neutral ratios exhibit the same trend and similar orders of magnitude compared with those of experimental measurements. Although thermal proton transfer may not generate all of the ions observed in MALDI, the calculations demonstrated that thermally induced reactions play a crucial role in UV-MALDI.

  7. {sup 252}Cf plasma desorption and laser desorption mass spectrometry for the determination of molecular weight distribution of coal derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, B.R.; Bartle, K.D.; Ross, A.B.; Herod, A.A.; Kandiyoti, R.; Larsen, J.W. [University of Leeds, Leeds (United Kingdom). School of Chemistry

    1999-11-01

    A detailed knowledge of the molecular mass (MM) distribution in coal and its derived products is essential for a fundamental understanding of coal structure, and of the processes occurring during coal conversion. Fractionation using size exclusion chromatography (s.e.c.) using N-methyl-2-pyrrolidinone as the mobile phase has been applied to such materials and has provided improved MM distributions. Absolute calibration has been provided using matrix assisted laser desorption ionisation mass spectrometry (MAl.d.I.-m.s.). An alternative method of volatilising and ionising large molecules for mass spectrometry (m.s.) is {sup 252}Cf plasma desorption ({sup 252}Cf p.d.-m.s.). This involves the use of energetic fission fragments from the decay of {sup 252}Cf and produces mass spectra consisting predominantly of molecular ions from a range of polymers and biomolecules. This has been used by other workers to determine the molecular weight distribution of heavy distillation residues obtained from coal liquefaction processes either unfractionated or fractionated into broad fractions. Generally, a good agreement was obtained between values of MM determined by {sup 252}Cf p.d.-m.s. and s.e.c. A comparison is reported of MM distribution determined by {sup 252}Cf p.d.-m.s. and laser desorption mass spectrometry (l.d.-m.s.) for narrower fractions separated by s.e.c. from a coal tar pitch. 19 refs., 4 figs., 1 tab.

  8. Ambient Femtosecond Laser Vaporization and Nanosecond Laser Desorption Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Flanigan, Paul; Levis, Robert

    2014-06-01

    Recent investigations of ambient laser-based transfer of molecules into the gas phase for subsequent mass spectral analysis have undergone a renaissance resulting from the separation of vaporization and ionization events. Here, we seek to provide a snapshot of recent femtosecond (fs) duration laser vaporization and nanosecond (ns) duration laser desorption electrospray ionization mass spectrometry experiments. The former employs pulse durations of proteins, and even preserve the condensed phase of folded or unfolded protein structures according to the mass spectral charge state distribution, as demonstrated for cytochrome c and lysozyme. Because of the ability to vaporize and ionize multiple components from complex mixtures for subsequent analysis, near perfect classification of explosive formulations, plant tissue phenotypes, and even the identity of the manufacturer of smokeless powders can be determined by multivariate statistics. We also review the more mature field of nanosecond laser desorption for ambient mass spectrometry, covering the wide range of systems analyzed, the need for resonant absorption, and the spatial imaging of complex systems like tissue samples.

  9. Laser Desorption Supersonic Jet Spectroscopy of Hydrated Tyrosine

    Science.gov (United States)

    Oba, Hikari; Shimozono, Yoko; Ishiuchi, Shun-Ichi; Fujii, Masaaki; Carcabal, Pierre

    2013-06-01

    The structure of tyrosine (tyr) consists of amino-acid chain and phenol, and it has roughly two possible binding sites for water, amino-acid site and phenolic OH site. Investigating how water molecule binds to tyr will give fundamental information for hydrations of peptide and protein. Resonance enhanced multi photon ionization (REMPI) spectrum of tyr-water 1:1 cluster has already been reported by de Vries and co-workers, however, no analysis on the hydrated structures has been reported. In the REMPI spectrum, two clusters of bands are observed; one appears at ˜35600 cm^{-1} energy region which is the almost same with 0-0 transitions of tyr monomer, and another is observed at ˜300 cm^{-1} lower than the former. Based on the electronic transition energy of phenylalanine and the hydrated clusters, the former is expected to be derived from a structure that water binds to amino acid site. On the other hand, it is plausibly predicted that the latter originates from a structure that water binds to phenolic OH group, because the electronic transition of mono hydrated phenol is ˜300 cm^{-1} red-shifted from the monomer. We applied IR dip spectroscopy which can measure conformer selective IR spectra to the tyr-(H_{2}O)_{1} clusters by using laser desorption supersonic jet technique to confirm the assignments. Especially in the phenolic OH bound isomer, it was found that the intra molecular hydrogen bond within amino-acid chain, which is far from the water molecule and cannot interact directly with each other, is strengthened by the hydration. A. Abio-Riziq et al., J. Phys. Chem. A, 115, 6077 (2011). Y. Shimozono, et al., Phys. Chem. Chem. Phys., (2013) DOI: 10.1039/c3cp43573c. T. Ebata et al., Phys. Chem. Chem. Phys., 8, 4783 (2006). T. Watanabe et al., J. Chem. Phys., 105, 408 (1996).

  10. Unconventional resource's production under desorption-induced effects

    Directory of Open Access Journals (Sweden)

    S. Sina Hosseini Boosari

    2016-06-01

    We have developed a numerical model to study the effect of changes in porosity, permeability and compaction on four major U.S. shale formations considering their Langmuir isotherm desorption behavior. These resources include; Marcellus, New Albany, Barnett and Haynesville Shales. First, we introduced a model that is a physical transport of single-phase gas flow in shale porous rock. Later, the governing equations are implemented into a one-dimensional numerical model and solved using a fully implicit solution method. It is found that the natural gas production is substantially affected by desorption-induced porosity/permeability changes and geomechancis. This paper provides valuable insights into accurate modeling of unconventional reservoirs that is more significant when an even small correction to the future production prediction can enormously contribute to the U.S. economy.

  11. Rapid decompression and desorption induced energetic failure in coal

    Directory of Open Access Journals (Sweden)

    Shugang Wang

    2015-06-01

    Full Text Available In this study, laboratory experiments are conducted to investigate the rapid decompression and desorption induced energetic failure in coal using a shock tube apparatus. Coal specimens are recovered from Colorado at a depth of 610 m. The coal specimens are saturated with the strong sorbing gas CO2 for a certain period and then the rupture disc is suddenly broken on top of the shock tube to generate a shock wave propagating upwards and a rarefaction wave propagating downwards through the specimen. This rapid decompression and desorption has the potential to cause energetic fragmentation in coal. Three types of behaviors in coal after rapid decompression are found, i.e. degassing without fragmentation, horizontal fragmentation, and vertical fragmentation. We speculate that the characteristics of fracture network (e.g. aperture, spacing, orientation and stiffness and gas desorption play a role in this dynamic event as coal can be considered as a dual porosity, dual permeability, dual stiffness sorbing medium. This study has important implications in understanding energetic failure process in underground coal mines such as coal gas outbursts.

  12. Surface-assisted laser desorption ionization mass spectrometry techniques for application in forensics.

    Science.gov (United States)

    Guinan, Taryn; Kirkbride, Paul; Pigou, Paul E; Ronci, Maurizio; Kobus, Hilton; Voelcker, Nicolas H

    2015-01-01

    Matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) is an excellent analytical technique for the rapid and sensitive analysis of macromolecules (>700 Da), such as peptides, proteins, nucleic acids, and synthetic polymers. However, the detection of smaller organic molecules with masses below 700 Da using MALDI-MS is challenging due to the appearance of matrix adducts and matrix fragment peaks in the same spectral range. Recently, nanostructured substrates have been developed that facilitate matrix-free laser desorption ionization (LDI), contributing to an emerging analytical paradigm referred to as surface-assisted laser desorption ionization (SALDI) MS. Since SALDI enables the detection of small organic molecules, it is rapidly growing in popularity, including in the field of forensics. At the same time, SALDI also holds significant potential as a high throughput analytical tool in roadside, work place and athlete drug testing. In this review, we discuss recent advances in SALDI techniques such as desorption ionization on porous silicon (DIOS), nano-initiator mass spectrometry (NIMS) and nano assisted laser desorption ionization (NALDI™) and compare their strengths and weaknesses with particular focus on forensic applications. These include the detection of illicit drug molecules and their metabolites in biological matrices and small molecule detection from forensic samples including banknotes and fingerprints. Finally, the review highlights recent advances in mass spectrometry imaging (MSI) using SALDI techniques.

  13. Recent progress in application of carbon nanomaterials in laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Wang, Jing; Liu, Qian; Liang, Yong; Jiang, Guibin

    2016-04-01

    Carbon nanomaterials have attracted great interest over past decades owing to their unique physical properties, versatile functionalization chemistry, and biological compatibility. In this article, we review recent progress in application of carbon nanomaterials in laser desorption/ionization mass spectrometry (LDI MS). Various types of carbon nanomaterials, including fullerenes, carbon nanotubes, graphene, carbon nanodots, nanodiamond, nanofibers, nanohorns, and their derivative forms, are involved. The applications of these materials as new matrices or probes in matrix-assisted or surface-enhanced laser desorption/ionization mass spectrometry (MALDI or SELDI MS) are discussed. Finally, we summarize current challenges and give our perspectives on the future of applications of carbon nanomaterials in LDI MS.

  14. 5th International Workshop on Desorption Induced by Electronic Transitions

    CERN Document Server

    Jennison, Dwight R; Stechel, Ellen B; DIET V; Desorption induced by electronic transitions

    1993-01-01

    This volume in the Springer Series on Surface Sciences presents a recent account of advances in the ever-broadening field of electron-and photon-stimulated sur­ face processes. As in previous volumes, these advances are presented as the proceedings of the International Workshop on Desorption Induced by Electronic Transitions; the fifth workshop (DIET V) was held in Taos, New Mexico, April 1-4, 1992. It will be abundantly clear to the reader that "DIET" is not restricted to desorption, but has for several years included photochemistry, non-thermal surface modification, exciton self-trapping, and many other phenomena that are induced by electron or photon bombardment. However, most stimulated surface processes do share a common physics: initial electronic excitation, localization of the excitation, and conversion of electronic energy into nuclear kinetic energy. It is the rich variation of this theme which makes the field so interesting and fruitful. We have divided the book into eleven parts in orde...

  15. Laser Infrared Desorption Spectroscopy to Detect Complex Organic Molecules on Icy Planetary Surfaces

    Science.gov (United States)

    Sollit, Luke S.; Beegle, Luther W.

    2008-01-01

    Laser Desorption-Infrared Spectroscopy (LD-IR) uses an IR laser pulse to desorb surface materials while a spectrometer measures the emission spectrum of the desorbed materials (Figure 1). In this example, laser desorption operates by having the incident laser energy absorbed by near surface material (10 microns in depth). This desorption produces a plume that exists in an excited state at elevated temperatures. A natural analog for this phenomenon can be observed when comets approach the sun and become active and individual molecular emission spectra can be observed in the IR [1,2,3,4,5]. When this occurs in comets, the same species that initially emit radiation down to the ground state are free to absorb it, reducing the amount of detectable emission features. The nature of our technique results in absorption not occurring, because the laser pulse could easily be moved away form the initial desorption plume, and still have better spatial resolution then reflectance spectroscopy. In reflectance spectroscopy, trace components have a relatively weak signal when compared to the entire active nature of the surface. With LDIR, the emission spectrum is used to identify and analyze surface materials.

  16. Laser Infrared Desorption Spectroscopy to Detect Complex Organic Molecules on Icy Planetary Surfaces

    Science.gov (United States)

    Sollit, Luke S.; Beegle, Luther W.

    2008-01-01

    Laser Desorption-Infrared Spectroscopy (LD-IR) uses an IR laser pulse to desorb surface materials while a spectrometer measures the emission spectrum of the desorbed materials (Figure 1). In this example, laser desorption operates by having the incident laser energy absorbed by near surface material (10 microns in depth). This desorption produces a plume that exists in an excited state at elevated temperatures. A natural analog for this phenomenon can be observed when comets approach the sun and become active and individual molecular emission spectra can be observed in the IR [1,2,3,4,5]. When this occurs in comets, the same species that initially emit radiation down to the ground state are free to absorb it, reducing the amount of detectable emission features. The nature of our technique results in absorption not occurring, because the laser pulse could easily be moved away form the initial desorption plume, and still have better spatial resolution then reflectance spectroscopy. In reflectance spectroscopy, trace components have a relatively weak signal when compared to the entire active nature of the surface. With LDIR, the emission spectrum is used to identify and analyze surface materials.

  17. 2,5-Dihydroxybenzoic acid: laser desorption/ionisation as a function of elevated temperature

    Science.gov (United States)

    Wallace, W. E.; Arnould, M. A.; Knochenmuss, R.

    2005-03-01

    The temperature dependence of laser desorption/ionization (LDI) ion yields has been measured for 2,5-dihydroxybenzoic acid (2,5-DHB) single crystals from room temperature to 160 °C using time-of-flight (TOF) mass spectrometry. A steep rise in ion production occurs at 90 °C, achieving a maximum at 120 °C, then decreases sharply to a minimum at 140 °C, and returns to a second maximum at 150 °C. Above 160 °C, useful information could not be obtained because of rapid volatilization of the sample into the vacuum. The overall trend in ion production, but not some of the details, is well described by a recent two-step theory of the laser desorption/ionization process, which takes into account the temperature-dependent effects of plume expansion. Measuring the background vacuum composition with a quadrupole mass spectrometer residual gas analyzer (RGA) showed an increase in thermal desorption of 2,5-DHB starting at 90 °C and maximizing at 130 °C. The increased neutral production by thermal desorption is believed to be the cause of the decrease in LDI ion production due to reduced pooling probabilities for laser-excited 2,5-DHB molecules. Thermal dehydration, condensation, and decarboxylation increase the volume of gas released at high temperatures which also serve to decrease LDI ion production at elevated temperatures. Lastly, to confirm the mass spectrometry results, the thermal desorption of 2,5-DHB single crystals under vacuum was measured using a quartz-crystal microbalance (QCM). The onset of desorption was found to occur at 90 °C and the maximum desorption rate was found at 135 °C.

  18. 3rd International Workshop on Desorption Induced by Electronic Transitions

    CERN Document Server

    Knotek, Michael

    1988-01-01

    These proceedings are the result of the third international workshop on Desorption Induced by Electronic Transitions, DIET III, which took place on Shelter Island, NY, May. 20-22, 1987. The work contained in this volume is an excellent summary of the current status of the field and should be a valuable reference text for both "seasoned" researchers and newcomers in the field of DIET. Based on the success of the meeting it seems clear that interest and enthusiasm in the field is strong. It is also apparent, from the many lively discussions during the meeting, that many unanswered questions (and controversies) remain to be solved. It was particularly pleasing to see many new participants from new and rapidly advancing fields, ranging from gas phase dynamics to semiconductor processing. The resulting cross-fertilization from these separate but related fields is playing an important role in helping us understand desorption processes at solid surfaces. In general, the topics covered during the course of the worksh...

  19. Characterisation of bacteria by matrix-assisted laser desorption/ionisation and electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van

    2000-01-01

    Chemical analysis for the characterisation of micro-organisms is rapidly evolving, after the recent advent of new ionisation methods in mass spectrometry (MS): electrospray (ES) and matrix-assisted laser desorption/ionisation (MALDI). These methods allow quick characterisation of micro-organisms, ei

  20. Bioaerosol detection by aerosol TOF-mass spectrometry: Application of matrix assisted laser desorption/ionisation

    NARCIS (Netherlands)

    Wuijckhuijse, A.L. van; Stowers, M.A.; Kientz, Ch.E.; Marijnissen, J.C.M.; Scarlett, B.

    2000-01-01

    In previous publications the use of an aerosol time of flight mass spectrometer was reported for the on-line measurements of aerosols (Weiss 1997, Kievit 1995). The apparatus is capable of measuring the size as well as the chemical composition, by the use of Laser Desorption/Ionisation (LDI), of an

  1. Identification of Bacteria Using Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry

    Science.gov (United States)

    Kedney, Mollie G.; Strunk, Kevin B.; Giaquinto, Lisa M.; Wagner, Jennifer A.; Pollack, Sidney; Patton, Walter A.

    2007-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS or simply MALDI) has become ubiquitous in the identification and analysis of biomacromolecules. As a technique that allows for the molecular weight determination of otherwise nonvolatile molecules, MALDI has had a profound impact in the molecular…

  2. Laser Desorption Mass Spectrometry for High Throughput DNA Analysis and Its Applications

    Energy Technology Data Exchange (ETDEWEB)

    Allman, S.L.; Chen, C.H.; Golovlev, V.V.; Isola, N.R.; Matteson, K.J.; Potter, N.T.; Taranenko, N.I.

    1999-01-23

    Laser desorption mass spectrometry (LDMS) has been developed for DNA sequencing, disease diagnosis, and DNA Fingerprinting for forensic applications. With LDMS, the speed of DNA analysis can be much faster than conventional gel electrophoresis. No dye or radioactive tagging to DNA segments for detection is needed. LDMS is emerging as a new alternative technology for DNA analysis.

  3. Tandem Mass Spectrometry on a Miniaturized Laser Desorption Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Li, Xiang; Cornish, Timothy; Getty, Stephanie A.; Brinckerhoff, William B.

    2016-01-01

    Tandem mass spectrometry (MSMS) is a powerful and widely-used technique for identifying the molecular structure of organic constituents of a complex sample. Application of MSMS to the study of unknown planetary samples on a remote space mission would contribute to our understanding of the origin, evolution, and distribution of extraterrestrial organics in our solar system. Here we report on the realization of MSMS on a miniaturized laser desorption time-of-flight mass spectrometer (LD-TOF-MS), which is one of the most promising instrument types for future planetary missions. This achievement relies on two critical components: a curved-field reflectron and a pulsed-pin ion gate. These enable use of the complementary post-source decay (PSD) and laser-assisted collision induced dissociation (L-CID) MSMS methods on diverse measurement targets with only modest investment in instrument resources such as volume and weight. MSMS spectra of selected molecular targets in various organic standards exhibit excellent agreement when compared with results from a commercial, laboratory-scale TOF instrument, demonstrating the potential of this powerful technique in space and planetary environments.

  4. Formation of Metal-Related Ions in Matrix-Assisted Laser Desorption Ionization

    Science.gov (United States)

    Lee, Chuping; Lu, I.-Chung; Hsu, Hsu Chen; Lin, Hou-Yu; Liang, Sheng-Ping; Lee, Yuan-Tseh; Ni, Chi-Kung

    2016-09-01

    In a study of the metal-related ion generation mechanism in matrix-assisted laser desorption ionization (MALDI), crystals of matrix used in MALDI were grown from matrix- and salt-containing solutions. The intensities of metal ion and metal adducts of the matrix ion obtained from unwashed crystals were higher than those from crystals washed with deionized water, indicating that metal ions and metal adducts of the matrix ions are mainly generated from the surface of crystals. The contributions of preformed metal ions and metal adducts of the matrix ions inside the matrix crystals were minor. Metal adducts of the matrix and analyte ion intensities generated from a mixture of dried matrix, salt, and analyte powders were similar to or higher than those generated from the powder of dried droplet crystals, indicating that the contributions of the preformed metal adducts of the matrix and analyte ions were insignificant. Correlation between metal-related ion intensity fluctuation and protonated ion intensity fluctuation was observed, indicating that the generation mechanism of the metal-related ions is similar to that of the protonated ions. Because the thermally induced proton transfer model effectively describes the generation of the protonated ions, we suggest that metal-related ions are mainly generated from the salt dissolution in the matrix melted by the laser.

  5. Laser desorption and time-of-flight mass spectrometry. Fundamentals .Applications; Desorption laser et spectrometrie de masse par temps de vol. Aspects fondamentaux. Applications

    Energy Technology Data Exchange (ETDEWEB)

    Chaurand, P.

    1994-11-01

    Time-of-flight mass spectrometry is a very powerful technique for the analysis of heavy molecular ions (100 000 u and more). The ejection in the gas phase and the ionization of these molecules is now possible through the MALDI technique (Matrix Assisted Laser Desorption Ionization). This technique consists in mixing the heavy molecules to be analysed with a organic matrix which absorbs at the wavelength of the laser. The necessary irradiance are of the order of 10{sup 6} W/cm{sup 2}. In these conditions we have shown that the mass resolutions are optimum and that the relative mass accuracies are of the order of 10{sup -4}. We have also demonstrated that the emission angle of the molecular ions in MALDI depends on the incident angle of the laser light. During the desorption process, the molecular ions are emitted in the opposite direction of the incident laser light. This effect is particularly important for the design of the accelerating stage of the time-of-flight spectrometers. Problems relative to the detection of these heavy molecular ions have been studied in details between 0.5 10{sup 4} m/s and 10{sup 5} m/s. The velocity threshold of the electronic emission is lower than the value of 0.5 10{sup 4} m/s. The relation between the electronic emission and the projectile velocity is complex. Finally, examples on mass identification of C{sub 60} molecules and derivated C{sub 60} are presented. Desorption methods are compared. (author). 32 refs., 34 figs.

  6. Derivatization of small biomolecules for optimized matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Tholey, Andreas; Wittmann, Christoph; Kang, Min-Jung; Bungert, Ditte; Hollemeyer, Klaus; Heinzle, Elmar

    2002-09-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is a powerful tool for the measurement of low molecular mass compounds of biological interest. The limitations for this method are the volatility of many analytes, possible interference with matrix signals or bad ionization or desorption behavior of the compounds. We investigated the application of well-known and straightforward one-pot derivatization procedures to circumvent these problems. The derivatizations tested allow the measurement and the labeling of alcohols, aldehydes and ketones, carboxylic acids, alpha-ketocarboxylic acids and amines.

  7. Non-traditional applications of laser desorption/ionization mass spectrometry

    Science.gov (United States)

    McAlpin, Casey R.

    Seven studies were carried out using laser desorption/ionization mass spectrometry (LDI MS) to develop enhanced methodologies for a variety of analyte systems by investigating analyte chemistries, ionization processes, and elimination of spectral interferences. Applications of LDI and matrix assisted laser/desorption/ionization (MALDI) have been previously limited by poorly understood ionization phenomena, and spectral interferences from matrices. Matrix assisted laser desorption ionization MS is well suited to the analysis of proteins. However, the proteins associated with bacteriophages often form complexes which are too massive for detection with a standard MALDI mass spectrometer. As such, methodologies for pretreatment of these samples are discussed in detail in the first chapter. Pretreatment of bacteriophage samples with reducing agents disrupted disulfide linkages and allowed enhanced detection of bacteriophage proteins. The second chapter focuses on the use of MALDI MS for lipid compounds whose molecular mass is significantly less than the proteins for which MALDI is most often applied. The use of MALDI MS for lipid analysis presented unique challenges such as matrix interference and differential ionization efficiencies. It was observed that optimization of the matrix system, and addition of cationization reagents mitigated these challenges and resulted in an enhanced methodology for MALDI MS of lipids. One of the challenges commonly encountered in efforts to expand MALDI MS applications is as previously mentioned interferences introduced by organic matrix molecules. The third chapter focuses on the development of a novel inorganic matrix replacement system called metal oxide laser ionization mass spectrometry (MOLI MS). In contrast to other matrix replacements, considerable effort was devoted to elucidating the ionization mechanism. It was shown that chemisorption of analytes to the metal oxide surface produced acidic adsorbed species which then

  8. Development of Laser Desorption Imaging Mass Spectrometry Methods to Investigate the Molecular Composition of Latent Fingermarks

    Science.gov (United States)

    Lauzon, Nidia; Dufresne, Martin; Chauhan, Vinita; Chaurand, Pierre

    2015-06-01

    For a century, fingermark analysis has been one of the most important and common methods in forensic investigations. Modern chemical analysis technologies have added the potential to determine the molecular composition of fingermarks and possibly identify chemicals a suspect may have come into contact with. Improvements in analytical detection of the molecular composition of fingermarks is therefore of great importance. In this regard, matrix-assisted laser desorption ionization (MALDI) and laser desorption ionization (LDI) imaging mass spectrometry (IMS) have proven to be useful technologies for fingermark analysis. In these analyses, the choice of ionizing agent and its mode of deposition are critical steps for the identification of molecular markers. Here we propose two novel and complementary IMS approaches for endogenous and exogenous substance detection in fingermarks: sublimation of 2-mercaptobenzothiazol (2-MBT) matrix and silver sputtering.

  9. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry identification of mycobacteria in routine clinical practice

    National Research Council Canada - National Science Library

    El Khéchine, Amel; Couderc, Carine; Flaudrops, Christophe; Raoult, Didier; Drancourt, Michel

    2011-01-01

    .... Matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS) has previously been proven to effectively identify mycobacteria grown in high-concentration inocula from collections...

  10. Unusual Fragmentation of Peptide and Protein in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Mitsuo Takayama

    2001-01-01

    Unusual amine - bond fragmentation on the peptide/protein backbone has been reported using matrix - assisted laser desorption/ionization time - of- flight mass spectrometry (MALDI - TOFMS)The amine - bond cleavage occurred without metastable decay, while the peptide - bond cleavage occurred with metastable decay of peptide ions in a drift region of TOF mass analyzer. It was presumed that the amine - bond cleavage occurred as a non - ergodic process independent of the ionization under MALDI conditions.

  11. Laser Desorption Ionization Mass Spectrometry Imaging of Drosophila Brain Using Matrix Sublimation versus Modification with Nanoparticles.

    Science.gov (United States)

    Phan, Nhu T N; Mohammadi, Amir Saeid; Dowlatshahi Pour, Masoumeh; Ewing, Andrew G

    2016-02-02

    Laser desorption ionization mass spectrometry (LDI-MS) is used to image brain lipids in the fruit fly, Drosophila, a common invertebrate model organism in biological and neurological studies. Three different sample preparation methods, including sublimation with two common organic matrixes for matrix-assisted laser desorption ionization (MALDI) and surface-assisted laser desorption ionization (SALDI) using gold nanoparticles, are examined for sample profiling and imaging the fly brain. Recrystallization with trifluoroacetic acid following matrix deposition in MALDI is shown to increase the incorporation of biomolecules with one matrix, resulting in more efficient ionization, but not for the other matrix. The key finding here is that the mass fragments observed for the fly brain slices with different surface modifications are significantly different. Thus, these approaches can be combined to provide complementary analysis of chemical composition, particularly for the small metabolites, diacylglycerides, phosphatidylcholines, and triacylglycerides, in the fly brain. Furthermore, imaging appears to be beneficial using modification with gold nanoparticles in place of matrix in this application showing its potential for cellular and subcellular imaging. The imaging protocol developed here with both MALDI and SALDI provides the best and most diverse lipid chemical images of the fly brain to date with LDI.

  12. Electrospray ionization and matrix assisted laser desorption/ionization mass spectrometry: powerful analytical tools in recombinant protein chemistry

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Svensson, B; Roepstorff, P

    1996-01-01

    Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy is presen......Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy...

  13. omniSpect: an open MATLAB-based tool for visualization and analysis of matrix-assisted laser desorption/ionization and desorption electrospray ionization mass spectrometry images.

    Science.gov (United States)

    Parry, R Mitchell; Galhena, Asiri S; Gamage, Chaminda M; Bennett, Rachel V; Wang, May D; Fernández, Facundo M

    2013-04-01

    We present omniSpect, an open source web- and MATLAB-based software tool for both desorption electrospray ionization (DESI) and matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) that performs computationally intensive functions on a remote server. These functions include converting data from a variety of file formats into a common format easily manipulated in MATLAB, transforming time-series mass spectra into mass spectrometry images based on a probe spatial raster path, and multivariate analysis. OmniSpect provides an extensible suite of tools to meet the computational requirements needed for visualizing open and proprietary format MSI data.

  14. Study of the mechanisms of heavy-ion induced desorption on accelerator-relevant materials; Untersuchung der Mechanismen schwerioneninduzierter Desorption an beschleunigerrelevanten Materialien

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Markus

    2008-02-22

    The ion beam loss induced desorption is a performance limitation for low charge state heavy ion accelerators. If charge exchanged projectile ions get lost onto the beam pipe, desorption of gas is stimulated resulting in a pressure increase inside of the synchrotron and thus, a dramatically reduction of the beam life time. To minimize the amount of desorbed gas an experimental program has been started to measure the desorption yields (released gas molecules per incident ion) of various materials and different projectile ions. The present work is a contribution to the understanding of the physical processes behind the ion beam loss induced desorption. The yield measurements by the pressure rise method have been combined for the rst time with in situ ion beam analysis technologies such as ERDA and RBS. With this unique method the desorption behavior of a sample can be correlated to its surface and bulk properties. The performed experiments with 1,4 MeV/u Xenon-Ions show that the ion induced desorption is mainly a surface effect. Sputtered oxide layers or impurities do not contribute to the desorbed gas significantly. Nevertheless bulk properties play an important role in the desorption strength. Pure metallic samples desorb less gas than isolating materials under swift heavy ion irradiation. From the experimental results it was possible to estimate the desorption yields of various materials under ion bombardment by means of an extended inelastic thermal-spike-model. The extension is the combination of the thermal-spike's temperature map with thermal desorption. Within this model the ion induced desorption can be regarded as the release of adsorbates from a transient overheated spot on the samples surface around the ion impact. Finally a copper substrate with a gold coated surface was developed and proposed as a suitable material for a beam loss collimator with minimum desorption to ensure the performance of GSI's SIS18 in high current beam operation. (orig.)

  15. Laser induced nuclear reactions

    Science.gov (United States)

    Ledingham, Ken; McCanny, Tom; Graham, Paul; Fang, Xiao; Singhal, Ravi; Magill, Joe; Creswell, Alan; Sanderson, David; Allott, Ric; Neely, David; Norreys, Peter; Santala, Marko; Zepf, Matthew; Watts, Ian; Clark, Eugene; Krushelnick, Karl; Tatarakis, Michael; Dangor, Bucker; Machecek, Antonin; Wark, Justin

    1998-12-01

    Dramatic improvements in laser technology since 1984 have revolutionised high power laser technology. Application of chirped-pulse amplification techniques has resulted in laser intensities in excess of 1019W/cm2. In the mid to late eighties, C. K. Rhodes and K. Boyer discussed the possibility of shining laser light of this intensity onto solid surfaces and to cause nuclear transitions. In particular, irradiation of a uranium target could induce electro- and photofission in the focal region of the laser. In this paper it is shown that μCi of 62Cu can be generated via the (γ,n) reaction by a laser with an intensity of about 1019Wcm-2.

  16. Brominated Tyrosine and Polyelectrolyte Multilayer Analysis by Laser Desorption VUV Postionization and Secondary Ion Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    University of Illinois at Chicago; Blaze, Melvin M. T.; Takahashi, Lynelle; Zhou, Jia; Ahmed, Musahid; Gasper, Gerald; Pleticha, F. Douglas; Hanley, Luke

    2011-03-14

    The small molecular analyte 3,5-dibromotyrosine (Br2Y) and chitosan-alginate polyelectrolyte multilayers (PEM) with and without adsorbed Br2Y were analyzed by laser desorption postionization mass spectrometry (LDPI-MS). LDPI-MS using 7.87 eV laser and tunable 8 ? 12.5 eV synchrotron vacuum ultraviolet (VUV) radiation found that desorption of clusters from Br2Y films allowed detection by≤8 eV single photon ionization. Thermal desorption and electronic structure calculations determined the ionization energy of Br2Y to be ~;;8.3?0.1 eV and further indicated that the lower ionization energies of clusters permitted their detection at≤8 eV photon energies. However, single photon ionization could only detect Br2Y adsorbed within PEMs when using either higher photon energies or matrix addition to the sample. All samples were also analyzed by 25 keV Bi3 + secondary ion mass spectrometry (SIMS), with the negative ion spectra showing strong parent ion signal which complemented that observed by LDPI-MS. The negative ion SIMS depended strongly on the high electron affinity of this specific analyte and the analyte?s condensed phase environment.

  17. Pyroelectricity Assisted Infrared-Laser Desorption Ionization (PAI-LDI) for Atmospheric Pressure Mass Spectrometry

    Science.gov (United States)

    Li, Yanyan; Ma, Xiaoxiao; Wei, Zhenwei; Gong, Xiaoyun; Yang, Chengdui; Zhang, Sichun; Zhang, Xinrong

    2015-08-01

    A new atmospheric pressure ionization method termed pyroelectricity-assisted infrared laser desorption ionization (PAI-LDI) was developed in this study. The pyroelectric material served as both sample target plate and enhancing ionization substrate, and an IR laser with wavelength of 1064 nm was employed to realize direct desorption and ionization of the analytes. The mass spectra of various compounds obtained on pyroelectric material were compared with those of other substrates. For the five standard substances tested in this work, LiNbO3 substrate produced the highest ion yield and the signal intensity was about 10 times higher than that when copper was used as substrate. For 1-adamantylamine, as low as 20 pg (132.2 fmol) was successfully detected. The active ingredient in (Compound Paracetamol and 1-Adamantylamine Hydrochloride Capsules), 1-adamantylamine, can be sensitively detected at an amount as low as 150 pg, when the medicine stock solution was diluted with urine. Monosaccharide and oligosaccharides in Allium Cepa L. juice was also successfully identified with PAI-LDI. The method did not require matrix-assisted external high voltage or other extra facility-assisted set-ups for desorption/ionization. This study suggested exciting application prospect of pyroelectric materials in matrix- and electricity-free atmospheric pressure mass spectrometry research.

  18. Matrix-assisted laser desorption mass spectrometry of gas-phase peptide-metal complexes

    Science.gov (United States)

    Hortal, Ana R.; Hurtado, Paola; Martínez-Haya, Bruno

    2008-12-01

    Cation attachment to a model peptide has been investigated in matrix-assisted laser desorption experiments. Angiotensin I (Asp-Arg-Val-Tyr-Ile-His-Pro-Phe-His-Leu) is chosen as a system for study, and Cu2+ and K+ salts are used as cationizing agents. Three fundamentally different types of samples are investigated: (1) a crystalline sample of Ang I, metal salt and MALDI matrix, prepared with the conventional dried droplet method; (2) a solvent-free fine powder mixture of the same three compounds, and (3) a solution of the angiotensin and the metal salt in an ionic liquid matrix (a molten organic salt that acts as a MALDI active solvent). Effective protonation and cationization of the peptide are achieved with the three methods. The transition metal systematically provides more efficient cationization than the alkali metal. At sufficiently high concentration of the salt, the attachment of up to four copper cations to the angiotensin is observed in the MALDI spectrum. In contrast, only one K+ cation is efficiently bound to the peptide. For a given salt concentration, the highest degree of cationization is obtained in the laser desorption from the ionic liquid matrix. This is attributed to the efficient transfer of free metal cations to the desorption plume, where the complexation takes place.

  19. Target Plate Material Influence on Fullerene-C60 Laser Desorption/Ionization Efficiency.

    Science.gov (United States)

    Zeegers, Guido P; Günthardt, Barbara F; Zenobi, Renato

    2016-04-01

    Systematic laser desorption/ionization (LDI) experiments of fullerene-C60 on a wide range of target plate materials were conducted to gain insight into the initial ion formation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The positive and negative ion signal intensities of precursor, fragment, and cluster ions were monitored, varying both the laser fluence (0-3.53 Jcm(-2)) and the ion extraction delay time (0-950 ns). The resulting species-specific ion signal intensities are an indication for the ionization mechanisms that contribute to LDI and the time frames in which they operate, providing insight in the (MA)LDI primary ionization. An increasing electrical resistivity of the target plate material increases the fullerene-C60 precursor and fragment anion signal intensity. Inconel 625 and Ti90/Al6/V4, both highly electrically resistive, provide the highest anion signal intensities, exceeding the cation signal intensity by a factor ~1.4 for the latter. We present a mechanism based on transient electrical field strength reduction to explain this trend. Fullerene-C60 cluster anion formation is negligible, which could be due to the high extraction potential. Cluster cations, however, are readily formed, although for high laser fluences, the preferred channel is formation of precursor and fragment cations. Ion signal intensity depends greatly on the choice of substrate material, and careful substrate selection could, therefore, allow for more sensitive (MA)LDI measurements. Graphical Abstract ᅟ.

  20. Target Plate Material Influence on Fullerene-C60 Laser Desorption/Ionization Efficiency

    Science.gov (United States)

    Zeegers, Guido P.; Günthardt, Barbara F.; Zenobi, Renato

    2016-04-01

    Systematic laser desorption/ionization (LDI) experiments of fullerene-C60 on a wide range of target plate materials were conducted to gain insight into the initial ion formation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The positive and negative ion signal intensities of precursor, fragment, and cluster ions were monitored, varying both the laser fluence (0-3.53 Jcm-2) and the ion extraction delay time (0-950 ns). The resulting species-specific ion signal intensities are an indication for the ionization mechanisms that contribute to LDI and the time frames in which they operate, providing insight in the (MA)LDI primary ionization. An increasing electrical resistivity of the target plate material increases the fullerene-C60 precursor and fragment anion signal intensity. Inconel 625 and Ti90/Al6/V4, both highly electrically resistive, provide the highest anion signal intensities, exceeding the cation signal intensity by a factor ~1.4 for the latter. We present a mechanism based on transient electrical field strength reduction to explain this trend. Fullerene-C60 cluster anion formation is negligible, which could be due to the high extraction potential. Cluster cations, however, are readily formed, although for high laser fluences, the preferred channel is formation of precursor and fragment cations. Ion signal intensity depends greatly on the choice of substrate material, and careful substrate selection could, therefore, allow for more sensitive (MA)LDI measurements.

  1. Large Scale Nanoparticle Screening for Small Molecule Analysis in Laser Desorption Ionization Mass Spectrometry.

    Science.gov (United States)

    Yagnik, Gargey B; Hansen, Rebecca L; Korte, Andrew R; Reichert, Malinda D; Vela, Javier; Lee, Young Jin

    2016-09-20

    Nanoparticles (NPs) have been suggested as efficient matrixes for small molecule profiling and imaging by laser-desorption ionization mass spectrometry (LDI-MS), but so far there has been no systematic study comparing different NPs in the analysis of various classes of small molecules. Here, we present a large scale screening of 13 NPs for the analysis of two dozen small metabolite molecules. Many NPs showed much higher LDI efficiency than organic matrixes in positive mode and some NPs showed comparable efficiencies for selected analytes in negative mode. Our results suggest that a thermally driven desorption process is a key factor for metal oxide NPs, but chemical interactions are also very important, especially for other NPs. The screening results provide a useful guideline for the selection of NPs in the LDI-MS analysis of small molecules.

  2. Laser Desorption Postionization Mass Spectrometry of Antibiotic-Treated Bacterial Biofilms using Tunable Vacuum Ultraviolet Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gasper, Gerald L; Takahashi, Lynelle K; Zhou, Jia; Ahmed, Musahid; Moore, Jerry F; Hanley, Luke

    2010-08-04

    Laser desorption postionization mass spectrometry (LDPI-MS) with 8.0 ? 12.5 eV vacuum ultraviolet synchrotron radiation is used to single photon ionize antibiotics andextracellular neutrals that are laser desorbed both neat and from intact bacterial biofilms. Neat antibiotics are optimally detected using 10.5 eV LDPI-MS, but can be ionized using 8.0 eV radiation, in agreement with prior work using 7.87 eV LDPI-MS. Tunable vacuum ultraviolet radiation also postionizes laser desorbed neutrals of antibiotics and extracellular material from within intact bacterial biofilms. Different extracellular material is observed by LDPI-MS in response to rifampicin or trimethoprim antibiotic treatment. Once again, 10.5 eV LDPI-MS displays the optimum trade-off between improved sensitivity and minimum fragmentation. Higher energy photons at 12.5 eV produce significant parent ion signal, but fragment intensity and other low mass ions are also enhanced. No matrix is added to enhance desorption, which is performed at peak power densities insufficient to directly produce ions, thus allowing observation of true VUV postionization mass spectra of antibiotic treated biofilms.

  3. Cosmetic Analysis Using Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging (MALDI-MSI

    Directory of Open Access Journals (Sweden)

    Rodrigo Ramos Catharino

    2013-03-01

    Full Text Available A new “omic” platform—Cosmetomics—that proves to be extremely simple and effective in terms of sample preparation and readiness for data acquisition/interpretation is presented. This novel approach employing Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging (MALDI-MSI for cosmetic analysis has proven to readily identify and quantify compounds of interest. It also allows full control of all the production phases, as well as of the final product, by integration of both analytical and statistical data. This work has focused on products of daily use, namely nail polish, lipsticks and eyeliners of multiple brands sold in the worldwide market.

  4. Measurement of Chiral Recognition Properties of Crown Ethers Using Matrix Assisted Laser Desorption Ionization Mass Spectrometry

    OpenAIRE

    SAWADA, Masami; Harada, Manabu; TAKAI, Yoshio; NAKANO, Kazurou; Kuroda, Masao; ARAKAWA, Ryuichi; 荒川, 隆一

    2000-01-01

    Hydrogen bonding host-guest complex ions between chiral crown ethers and chiral amino acid ester salts, detected by matrix assisted laser desorption ionization (MALDI) mass spectrometry (MS) with a DHBA or MSA matrix, were studied on the view point of chiral recognition properties of the chiral crown hosts. The chiral recognition property (IR/IS-dn value≅1.0) obtained by the present MALDI-MS is sharply different from the IR/IS-dn value obtained by FAB-MS or ESI-MS (≠1.0) in the same host-gues...

  5. Heavy-ion-induced desorption of organic molecules studied with Langmuir-Blodgett multilayer systems (DE)

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.; Schoppmann, C.; Brandl, D.; Ostrowski, A.; Voit, H. (Physikalisches Institut der Universitaet Erlangen-Nuernberg D-8520 Erlangen, (Germany)); Johannsmann, D.; Knoll, W. (Max-Planck-Institut fuer Polymerforschung Mainz D-6500 Mainz, (Germany))

    1991-07-01

    Heavy-ion-induced desorption has been studied with samples consisting of Langmuir-Blodgett films made from Cd salts of fatty acids. The experiments confirm the result of previous works that heavy ions drill a crater into the sample surface. The explicit dependence of the crater depth on the electronic energy loss could be determined from the experiments. The craters exhibit the shape of a symmetric cone as obtained from a desorption model applied to the experimental data.

  6. Highly reproducible laser beam scanning device for an internal source laser desorption microprobe Fourier transform mass spectrometer

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2002-03-01

    Traditionally, mass spectrometry has relied on manipulating the sample target to provide scanning capabilities for laser desorption microprobes. This has been problematic for an internal source laser desorption Fourier transform mass spectrometer (LD-FTMS) because of the high magnetic field (7 Tesla) and geometric constraints of the superconducting magnet bore. To overcome these limitations, we have implemented a unique external laser scanning mechanism for an internal source LD-FTMS. This mechanism provides adjustable resolution enhancement so that the spatial resolution at the target is not limited to that of the stepper motors at the light source (˜5 μm/step). The spatial resolution is now limited by the practical optical diffraction limit of the final focusing lens. The scanning mechanism employs a virtual source that is wavelength independent up to the final focusing lens, which can be controlled remotely to account for focal length dependence on wavelength. A binary index provides an automatic alignment feature. The virtual source is located ˜9 ft from the sample; therefore, it is completely outside of the vacuum system and beyond the 50 G line of the fringing magnetic field. To eliminate reproducibility problems associated with vacuum pump vibrations, we have taken advantage of the magnetic field inherent to the FTMS to utilize Lenz's law for vibrational dampening. The LD-FTMS microprobe has exceptional reproducibility, which enables successive mapping sequences for depth-profiling studies.

  7. Comparative mass spectrometric analyses of Photofrin oligomers by fast atom bombardment mass spectrometry, UV and IR matrix-assisted laser desorption/ionization mass spectrometry, electrospray ionization mass spectrometry and laser desorption/jet-cooling photoionization mass spectrometry.

    Science.gov (United States)

    Siegel, M M; Tabei, K; Tsao, R; Pastel, M J; Pandey, R K; Berkenkamp, S; Hillenkamp, F; de Vries, M S

    1999-06-01

    Photofrin (porfimer sodium) is a porphyrin derivative used in the treatment of a variety of cancers by photodynamic therapy. This oligomer complex and a variety of porphyrin monomers, dimers and trimers were analyzed with five different mass spectral ionization techniques: fast atom bombardment, UV and IR matrix-assisted laser desorption/ionization, electrospray ionization, and laser desorption/jet-cooling photoionization. All five approaches resulted in very similar oligomer distributions with an average oligomer length of 2.7 +/- 0.1 porphyrin units. In addition to the Photofrin analysis, this study provides a side-by-side comparison of the spectra for the five different mass spectrometric techniques.

  8. Investigation of thin ZnO layers in view of laser desorption-ionization

    Energy Technology Data Exchange (ETDEWEB)

    Grechnikov, A A; Borodkov, A S [Vernadsky Institute of Geochemistry and Analytical Chemistry, Russian Academy of Sciences, 19 Kosygin Str., 119991 Moscow (Russian Federation); Georgieva, V B [Georgi Nadjakov Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee, 1784 Sofia (Bulgaria); Alimpiev, S S; Nikiforov, S M; Simanovsky, Ya O [General Physics Institute, Russian Academy of Sciences, 38 Vavilov Str., 119991 Moscow (Russian Federation); Dimova-Malinovska, D; Angelov, O I, E-mail: lazarova@issp.bas.b [Laboratory for Solar Energy and New Energy Sources, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee, 1784 Sofia (Bulgaria)

    2010-04-01

    Thin zinc oxide films (ZnO) were developed as a matrix-free platform for surface assisted laser desorption-ionization (SALDI) time-of-flight mass spectrometry. The ZnO films were deposited by RF magnetron sputtering of ZnO ceramic targets in Ar atmospheres on monocrystalline silicon. The generation under UV (355 nm) laser irradiation of positive ions of atenolol, reserpine and gramicidin S from the ZnO layers deposited was studied. All analytes tested were detected as protonated molecules with no or very structure-specific fragmentation. The mass spectra obtained showed low levels of chemical background noise. All ZnO films studied exhibited high stability and good reproducibility. The detection limits for test analytes are in the 10 femtomol range.

  9. Applications of electrospray laser desorption ionization mass spectrometry for document examination.

    Science.gov (United States)

    Cheng, Sy-Chyi; Lin, Yu-Shan; Huang, Ming-Zong; Shiea, Jentaie

    2010-01-01

    We have employed electrospray laser desorption ionization mass spectrometry (ELDI-MS) to rapidly characterize certain classes of compounds--the inks within the characters made by inks and inkjet printer on regular paper and the chemical compounds within thermal papers. This ELDI-MS approach allowed the ink and paper samples to be distinguished in terms of their chemical compositions. Sample pretreatment was unnecessary and the documents were practically undamaged after examination. The ink chemicals on the documents were desorbed through laser irradiation (sampling spot area: <100 microm(2)); the desorbed molecules then entered an electrospray plume--prepared from an acidic methanol/water solution (50%)--where they became ionized through fusion or ion-molecule reactions with the charged solvent species and droplets in the plume.

  10. Identification of Microalgae by Laser Desorption/Ionization Mass Spectrometry Coupled with Multiple Nanomatrices.

    Science.gov (United States)

    Peng, Lung-Hsiang; Unnikrishnan, Binesh; Shih, Chi-Yu; Hsiung, Tung-Ming; Chang, Jeng; Hsu, Pang-Hung; Chiu, Tai-Chia; Huang, Chih-Ching

    2016-04-01

    In this study, we demonstrate a simple method to identify microalgae by surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using three different substrates: HgSe, HgTe, and HgTeSe nanostructures. The fragmentation/ionization processes of complex molecules in algae varied according to the heat absorption and transfer efficiency of the nanostructured matrices (NMs). Therefore, the mass spectra obtained for microalgae showed different patterns of m/z values for different NMs. The spectra contained both significant and nonsignificant peaks. Constructing a Venn diagram with the significant peaks obtained for algae when using HgSe, HgTe, and HgTeSe NMs in m/z ratio range 100-1000, a unique relationship among the three sets of values was obtained. This unique relationship of sets is different for each species of microalgae. Therefore, by observing the particular relationship of sets, we successfully identified different algae such as Isochrysis galbana, Emiliania huxleyi, Thalassiosira weissflogii, Nannochloris sp., Skeletonema cf. costatum, and Tetraselmis chui. This simple and cost-effective SALDI-MS analysis method coupled with multi-nanomaterials as substrates may be extended to identify other microalgae and microorganisms in real samples. Graphical Abstract Identification of microalgae by surface-assisted laser desorption/ionization mass spectrometry coupled with three different mercury-based nanosubstrates.

  11. Revisiting the quantitative features of surface-assisted laser desorption/ionization mass spectrometric analysis.

    Science.gov (United States)

    Wu, Ching-Yi; Lee, Kai-Chieh; Kuo, Yen-Ling; Chen, Yu-Chie

    2016-10-28

    Surface-assisted laser desorption/ionization (SALDI) coupled with mass spectrometry (MS) is frequently used to analyse small organics owing to its clean background. Inorganic materials can be used as energy absorbers and the transfer medium to facilitate the desorption/ionization of analytes; thus, they are used as SALDI-assisting materials. Many studies have demonstrated the usefulness of SALDI-MS in quantitative analysis of small organics. However, some characteristics occurring in SALDI-MS require certain attention to ensure the reliability of the quantitative analysis results. The appearance of a coffee-ring effect in SALDI sample preparation is the primary factor that can affect quantitative SALDI-MS analysis results. However, to the best of our knowledge, there are no reports relating to quantitative SALDI-MS analysis that discuss or consider this effect. In this study, the coffee-ring effect is discussed using nanoparticles and nanostructured substrates as SALDI-assisting materials to show how this effect influences SALDI-MS analysis results. Potential solutions for overcoming the existing problems are also suggested.This article is part of the themed issue 'Quantitative mass spectrometry'.

  12. Laser desorption time-of-flight mass spectrometry of vacuum UV photo-processed methanol ice

    Science.gov (United States)

    Paardekooper, D. M.; Bossa, J.-B.; Linnartz, H.

    2016-07-01

    Context. Methanol in the interstellar medium mainly forms upon sequential hydrogenation of solid CO. With typical abundances of up to 15% (with respect to water) it is an important constituent of interstellar ices where it is considered as a precursor in the formation of large and complex organic molecules (COMs), e.g. upon vacuum UV (VUV) photo-processing or exposure to cosmic rays. Aims: This study aims at detecting novel complex organic molecules formed during the VUV photo-processing of methanol ice in the laboratory using a technique more sensitive than regular surface diagnostic tools. In addition, the formation kinetics of the main photo-products of methanol are unravelled for an astronomically relevant temperature (20 K) and radiation dose. Methods: The VUV photo-processing of CH3OH ice is studied by applying laser desorption post-ionisation time-of-flight mass spectrometry (LDPI TOF-MS), and analysed by combining molecule-specific fragmentation and desorption features. Results: The mass spectra correspond to fragment ions originating from a number of previously recorded molecules and from new COMs, such as the series (CO)xH, with x = 3 and y prebiotic glycerin belongs. The formation of these large COMs has not been reported in earlier photolysis studies and suggests that such complex species may form in the solid state under interstellar conditions.

  13. Basic matrices in the analysis of non-covalent complexes by matrix-assisted laser desorption/ionization mass spectrometry

    NARCIS (Netherlands)

    Jespersen, S.; Niessen, W.M.A.; Tjaden, U.R.; Greef, J. van der

    1998-01-01

    A number of potential matrix candidates were investigated with regard to the importance of the pH in the matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) analysis of non-covalently bound protein complexes. The matrices examined were 2,5-dihydroxybenzoic acid (DHB), 4-hydroxy-

  14. Performance of matrix-assisted laser desorption-time of flight mass spectrometry for identification of clinical yeast isolates

    DEFF Research Database (Denmark)

    Rosenvinge, Flemming S; Dzajic, Esad; Knudsen, Elisa;

    2013-01-01

    Accurate and fast yeast identification is important when treating patients with invasive fungal disease as susceptibility to antifungal agents is highly species related. Matrix-assisted laser desorption-time of flight mass spectrometry (MALDI-TOF-MS) provides a powerful tool with a clear potential...

  15. Development of matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) for plant metabolite analysis

    Energy Technology Data Exchange (ETDEWEB)

    Korte, Andrew R [Iowa State Univ., Ames, IA (United States)

    2014-12-01

    This thesis presents efforts to improve the methodology of matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) as a method for analysis of metabolites from plant tissue samples. The first chapter consists of a general introduction to the technique of MALDI-MSI, and the sixth and final chapter provides a brief summary and an outlook on future work.

  16. Basic matrices in the analysis of non-covalent complexes by matrix-assisted laser desorption/ionization mass spectrometry

    NARCIS (Netherlands)

    Jespersen, S.; Niessen, W.M.A.; Tjaden, U.R.; Greef, J. van der

    1998-01-01

    A number of potential matrix candidates were investigated with regard to the importance of the pH in the matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) analysis of non-covalently bound protein complexes. The matrices examined were 2,5-dihydroxybenzoic acid (DHB), 4-hydroxy-

  17. Application of matrix-assisted laser desorption/ionization to on-line aerosol time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Stowers, M.A.; Wuijckhuijse, A.L. van; Marijnissen, J.C.M.; Scarlett, B.; Baar, B.L.M. van; Kientz, Ch.E.

    2000-01-01

    Matrix-assisted laser desorption/ionization (MALDI) mass spectra were obtained from single biological aerosol particles using an aerosol time-of- flight mass spectrometer (ATOFMS). The inlet to the ATOFMS was coupled with an evaporation/condensation flow cell that allowed the aerosol to be coated wi

  18. A novel sample preparation method of matrix-assisted laser desorption/ionization time of flight mass spectrometry for polystyrene

    Institute of Scientific and Technical Information of China (English)

    Shu Zhang; Zhen Wen Zhao; Lei Xiong; Bin Xin; Wei Hua Hu; Shao Xiang Xiong

    2007-01-01

    A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported.Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved.The mechanism was also analyzed.

  19. Quantum dots assisted laser desorption/ionization mass spectrometric detection of carbohydrates: qualitative and quantitative analysis.

    Science.gov (United States)

    Bibi, Aisha; Ju, Huangxian

    2016-04-01

    A quantum dots (QDs) assisted laser desorption/ionization mass spectrometric (QDA-LDI-MS) strategy was proposed for qualitative and quantitative analysis of a series of carbohydrates. The adsorption of carbohydrates on the modified surface of different QDs as the matrices depended mainly on the formation of hydrogen bonding, which led to higher MS intensity than those with conventional organic matrix. The effects of QDs concentration and sample preparation method were explored for improving the selective ionization process and the detection sensitivity. The proposed approach offered a new dimension to the application of QDs as matrices for MALDI-MS research of carbohydrates. It could be used for quantitative measurement of glucose concentration in human serum with good performance. The QDs served as a matrix showed the advantages of low background, higher sensitivity, convenient sample preparation and excellent stability under vacuum. The QDs assisted LDI-MS approach has promising application to the analysis of carbohydrates in complex biological samples.

  20. Manganese oxide nanoparticle-assisted laser desorption/ionization mass spectrometry for medical applications

    Directory of Open Access Journals (Sweden)

    Shu Taira, Kenji Kitajima, Hikaru Katayanagi, Eiichiro Ichiishi and Yuko Ichiyanagi

    2009-01-01

    Full Text Available We prepared and characterized manganese oxide magnetic nanoparticles (d =5.6 nm and developed nanoparticle-assited laser desorption/ionization (nano-PALDI mass spectrometry. The nanoparticles had MnO2 and Mn2O3 cores conjugated with hydroxyl and amino groups, and showed paramagnetism at room temperature. The nanoparticles worked as an ionization assisting reagent in mass spectroscopy. The mass spectra showed no background in the low m/z. The nanoparticles could ionize samples of peptide, drug and proteins (approx. 5000 Da without using matrix, i.e., 2,5-dihydroxybenzoic acid (DHB, 4-hydroxy-α-cinnamic acid (CHCA and liquid matrix, as conventional ionization assisting reagents. Post source decay spectra by nano-PALDI mass spectrometry will yield information of the chemical structure of analytes.

  1. Ammonium Ion Exchanged Zeolite for Laser Desorption/Ionization Mass Spectrometry of Phosphorylated Peptides

    Directory of Open Access Journals (Sweden)

    Mengrui Yang

    2015-01-01

    Full Text Available α-Cyano-4-hydroxycinnamic acid (CHCA, an organic matrix molecule for matrix-assisted laser desorption/ionization mass spectrometry, was adsorbed to NH4+-type zeolite surface, and this new matrix was used for the detection of low-molecular-weight compounds. It was found that this matrix could simplify the mass spectrum in the low-molecular-weight region and prevent interference from fragments and alkali metal ion adducted species. CHCA adsorbed to NH4+-type ZSM5 zeolite (CHCA/NH4ZSM5 was used to measure atropine and aconitine, two toxic alkaloids in plants. In addition, CHCA/NH4ZSM5 enabled us to detect phosphorylated peptides; peaks of the protonated peptides had higher intensities than the peaks observed using CHCA only.

  2. Beer fingerprinting by Matrix-Assisted Laser Desorption-Ionisation-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Šedo, Ondrej; Márová, Ivana; Zdráhal, Zbyněk

    2012-11-15

    A method allowing parallel fingerprinting of proteins and maltooligosaccharides directly from untreated beer samples is presented. These two classes of compounds were detected by Matrix-Assisted Laser Desorption-Ionisation-Time of Flight-Mass Spectrometry (MALDI-TOF-MS) analysis of beer mixed with 2,5-dihydroxybenzoic acid solution. The maltooligosaccharide profiles acquired from the MALDI sample spot center were not found characteristic for beers of different source and technology. On the other hand, according to profiles containing protein signals acquired from crystals formed on the border of the MALDI sample spot, we were able to distinguish beer samples of the same brand produced by different breweries. The discriminatory abilities of the method were further examined on a set of 17 lager beers, where the fingerprints containing protein signals enabled resolution of majority of examined brands. We propose MALDI-TOF-MS profiling as a rapid tool for beer brewing technology process monitoring, quality control, and determination of beer authenticity.

  3. Direct Surface Analysis of Fungal Species by Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Valentine, Nancy B.(BATTELLE (PACIFIC NW LAB)); Wahl, Jon H.(BATTELLE (PACIFIC NW LAB)); Kingsley, Mark T.(BATTELLE (PACIFIC NW LAB)); Wahl, Karen L.(BATTELLE (PACIFIC NW LAB))

    2001-12-01

    Intact spores and/or hyphae of Aspergillus niger, Rhizopus oryzae, Trichoderma reesei and Phanerochaete chrysosporium are analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). This study investigates various methods of sample preparation and matrices to determine optimum collection and analysis criteria for fungal analysis by MALDI-MS. Fungi are applied to the MALDI sample target as untreated, sonicated, acid/heat treated, or blotted directly from the fungal culture with double-stick tape. Ferulic acid or sinapinic acid matrix solution is layered over the dried samples and analyzed by MALDI-MS. Statistical analysis of the data show that simply using double stick tape to collect and transfer to a MALDI sample plate typically worked as well as the other preparation methods, but requires the least sample handling.

  4. Application of parylene for surface (polymer) enhanced laser desorption/ionization of synthetic polymers.

    Science.gov (United States)

    Miksa, Beata J; Sochacki, Marek; Sroka-Bartnicka, Anna; Uznański, Paweł; Nosal, Andrzej; Potrzebowski, Marek J

    2013-04-15

    Synthetic polymers of molecular masses up to a few kDa can be analyzed without the use of any matrix by direct laser desorption/ionization mass spectrometry (LDI-MS). In this technique, the surface of the sample plate plays a crucial role, and many attempts have been made to understand the influence of the surface on the ease of desorption. Since this technique requires no tedious sample pretreatment, it is a promising method for the rapid characterization of various synthetic polymers. Parylene (poly(p-xylylenes), PPX) was tested as a surface support for studying the molecular masses of biocompatible polymers: poly(ethylene glycol) (PEG), poly(L-lactide) (PLLA), and poly(methyl methacrylate) (PMMA). The average molecular masses of the polymers were: PEG (600.0 Da and 3.5 kDa), PMMA (2.0 kDa), and PLLA (2.8 kDa). LDI mass spectra of polymers deposited on parylene were enhanced by a factor of two over those obtained directly from the gold target plate. Modification of the surface of the target plate by the addition of a PPX layer extended the functionality of LDI-TOF MS, especially for the analysis of low-mass compounds. The LDI analysis using the PPX-coated target plate provided details of polymers including: end-group, composition, monomer unit, and molecular mass distribution. The average molecular weights of four tested polymers on the gold target plate and the PPX support were unchanged, indicating that sample degradation was not occurring despite the high energy of the laser beam. The LDI investigations showed that the PPX support boosted ion yields by a factor of two compared with the gold target plate. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Molecular dynamics investigation of desorption and ion separation following picosecond infrared laser (PIRL) ablation of an ionic aqueous protein solution

    Science.gov (United States)

    Zou, J.; Wu, C.; Robertson, W. D.; Zhigilei, L. V.; Miller, R. J. D.

    2016-11-01

    Molecular dynamics simulations were performed to characterize the ablation process induced by a picosecond infrared laser (PIRL) operating in the regime of desorption by impulsive vibrational excitation (DIVE) of a model peptide (lysozyme)/counter-ion system in aqueous solution. The simulations were performed for ablation under typical experimental conditions found within a time-of-flight mass spectrometer (TOF-MS), that is in vacuum with an applied electric field (E = ± 107 V/m), for up to 2 ns post-ablation and compared to the standard PIRL-DIVE ablation condition (E = 0 V/m). Further, a simulation of ablation under an extreme field condition (E = 1010 V/m) was performed for comparison to extend the effective dynamic range of the effect of the field on charge separation. The results show that the plume dynamics were retained under a typical TOF-MS condition within the first 1 ns of ablation. Efficient desorption was observed with more than 90% of water molecules interacting with lysozyme stripped off within 1 ns post-ablation. The processes of ablation and desolvation of analytes were shown to be independent of the applied electric field and thus decoupled from the ion separation process. Unlike under the extreme field conditions, the electric field inside a typical TOF-MS was shown to modify the ions' motion over a longer time and in a soft manner with no enhancement to fragmentation observed as compared to the standard PIRL-DIVE. The study indicates that the PIRL-DIVE ablation mechanism could be used as a new, intrinsically versatile, and highly sensitive ion source for quantitative mass spectrometry.

  6. Molecular dynamics investigation of desorption and ion separation following picosecond infrared laser (PIRL) ablation of an ionic aqueous protein solution.

    Science.gov (United States)

    Zou, J; Wu, C; Robertson, W D; Zhigilei, L V; Miller, R J D

    2016-11-28

    Molecular dynamics simulations were performed to characterize the ablation process induced by a picosecond infrared laser (PIRL) operating in the regime of desorption by impulsive vibrational excitation (DIVE) of a model peptide (lysozyme)/counter-ion system in aqueous solution. The simulations were performed for ablation under typical experimental conditions found within a time-of-flight mass spectrometer (TOF-MS), that is in vacuum with an applied electric field (E = ± 10(7) V/m), for up to 2 ns post-ablation and compared to the standard PIRL-DIVE ablation condition (E = 0 V/m). Further, a simulation of ablation under an extreme field condition (E = 10(10) V/m) was performed for comparison to extend the effective dynamic range of the effect of the field on charge separation. The results show that the plume dynamics were retained under a typical TOF-MS condition within the first 1 ns of ablation. Efficient desorption was observed with more than 90% of water molecules interacting with lysozyme stripped off within 1 ns post-ablation. The processes of ablation and desolvation of analytes were shown to be independent of the applied electric field and thus decoupled from the ion separation process. Unlike under the extreme field conditions, the electric field inside a typical TOF-MS was shown to modify the ions' motion over a longer time and in a soft manner with no enhancement to fragmentation observed as compared to the standard PIRL-DIVE. The study indicates that the PIRL-DIVE ablation mechanism could be used as a new, intrinsically versatile, and highly sensitive ion source for quantitative mass spectrometry.

  7. Novel Galvanic Nanostructures of Ag and Pd for Efficient Laser Desorption/Ionization of Low Molecular Weight Compounds

    Science.gov (United States)

    Silina, Yuliya E.; Meier, Florian; Nebolsin, Valeriy A.; Koch, Marcus; Volmer, Dietrich A.

    2014-05-01

    A simple approach for synthesis of palladium and silver nanostructures with readily adjustable morphologies was developed using galvanic electrochemical deposition, for application to surface-assisted laser desorption/ionization (SALDI) of small biological molecules. A range of fatty acids, triglycerides, carbohydrates, and antibiotics were investigated to assess the performance of the new materials. Intense analyte cations were generated from the galvanic surfaces upon UV laser irradiation such as potassium adducts for a film thickness 120 nm. Possible laser desorption/ionization mechanisms of these galvanic structures are discussed. The films exhibited self-organizing abilities and adjustable morphologies by changing electrochemical parameters. They did not require any stabilizing agents and were inexpensive and very easy to produce. SALDI analysis showed that the materials were stable under ambient conditions and analytical results with excellent measurement reproducibility and detection sensitivity similar to MALDI were obtained. Finally, we applied the galvanic surfaces to fast screening of natural oils with minimum sample preparation.

  8. Matrix-assisted laser desorption ion trap mass spectrometry: efficient isolation and effective fragmentation of peptide ions.

    Science.gov (United States)

    Qin, J; Chait, B T

    1996-07-01

    Effective analysis of the sequence of peptides using matrix-assisted laser desorption/ionization (MALDI) tandem ion trap mass spectrometry requires efficient mass isolation and the ability to induce extensive sequence-specific fragmentation. The present paper describes a new excitation scheme, which we term red-shifted off-resonance large-amplitude excitation (RSORLAE), that can deposit higher amounts of internal energy in ions than is feasible with conventional resonant excitation. The new method provides an effective means for inducing fragmentation of MALDI-produced peptide ions with m/z values up to 3500. Prior to excitation, it is necessary to isolate ions of interest with high efficiency. We demonstrate that isolation efficiencies of > 95% can be achieved by careful design of the rf scan functions used during ion isolation. In particular, sudden transitions in the amplitude of the rf field (from low to high amplitudes) must be avoided. The combined improvements in the efficiency for ion isolation and the efficacy of ion activation make MALDI tandem ion trap mass spectrometry a practical tool for the characterization of proteins with high sensitivity.

  9. Identification of colorants in pigmented pen inks by laser desorption mass spectrometry.

    Science.gov (United States)

    Papson, Kaitlin; Stachura, Sylwia; Boralsky, Luke; Allison, John

    2008-01-01

    Pigments are rapidly replacing dyes as colorants in pen and printer inks, due to their superior colors and stability. Unfortunately, tools commonly used in questioned document examination for analyzing pen inks, such as TLC, cannot be used for the analysis of insoluble pigments on paper. Laser desorption mass spectrometry is demonstrated here as a tool for analyzing pigment-based pen inks. A pulsed nitrogen laser can be focused onto a pen stroke from a pigmented ink pen on paper, and positive and negative ions representative of the pigment can be generated for subsequent mass spectrometric analysis. Targeted pens for this work were a set of Uni-ball 207 pigmented ink pens containing blue, light blue, orange, green, violet, red, pink, and black inks. Copper phthalocyanine was identified as the pigment used to make both blue inks. A mixture of halogenated copper phthalocyanines were identified in the green ink. Unexpectedly, the pink ink was found to contain a red pigment, Pigment Red 12, treated with a mixture of water-soluble dyes. Each sample yielded ions representative of the pigments present.

  10. Formation of aluminium, aluminium nitride and nitrogen clusters via laser ablation of nano aluminium nitride. Laser Desorption Ionisation and Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Panyala, Nagender Reddy; Prysiazhnyi, Vadym; Slavíček, Pavel; Černák, Mirko; Havel, Josef

    2011-06-30

    Laser Desorption Ionisation (LDI) and Matrix-Assisted Laser Desorption Ionisation (MALDI) Time-of-Flight Mass Spectrometry (TOFMS) were used to study the pulsed laser ablation of aluminium nitride (AlN) nano powder. The formation of Al(m)(+) (m=1-3), N(n)(+) (n=4, 5), AlN(n)(+) (n=1-5, 19, 21), Al(m)N(+) (m=2-3), Al(3)N(2)(+), Al(9)N(n)(+) (n=5, 7, 9, 11 and 15), Al(11)N(n)(+) (n=4, 6, 10, 12, 19, 21, 23, and 25), and Al(13)N(n)(+) (n=25, 31, 32, 33, 34, 35, and 36) clusters was detected in positive ion mode. Similarly, Al(m)(-) (m=1-3), AlN(n)(-) (n=1-3, 5), Al(m)N(-) (n=2, 3), Al(2)N(n)(-) (n=2-4, 28, 30), N(n)(-) (n=2, 3), Al(4)N(7)(-) Al(8)N(n)(-) (n=1-6), and Al(13)N(n)(-) (n=9, 18, 20, 22, 24, 26, 28, 33, 35, 37, 39, 41 and 43) clusters were observed in negative ion mode. The formation of the stoichiometric Al(10) N(10) cluster was shown to be of low abundance. On the contrary, the laser ablation of nano-AlN led mainly to the formation of nitrogen-rich Al(m)N(n) clusters in both negative and positive ion mode. The stoichiometry of the Al(m)N(n) clusters was determined via isotopic envelope analysis and computer modelling.

  11. Heavy-ion induced desorption yields of cryogenic surfaces bombarded with 4.2 MeV/u lead ions

    CERN Document Server

    Mahner, E; Evans, L; Kollmus, H; Küchler, D; Scrivens, R; Severin, D; Wengenroth, M; CERN. Geneva. ATS Department

    2011-01-01

    The ion-induced desorption experiment, installed in the CERN Heavy-Ion Accelerator LINAC 3, has been used to study the dynamic outgassing of cryogenic surfaces. Two different targets, bare and goldcoated copper, were bombarded under perpendicular impact with 4.2 MeV/u Pb54+ ions. Partial pressure rises of H2, CH4, CO, and CO2 and effective desorption yields were measured at 300, 77, and 6.3 K using single shot and continuous ion bombardment techniques. We find that the heavy-ion-induced desorption yield is temperature dependent and investigate the influence of CO gas cryosorbed at 6.3 K. The gain in desorption yield reduction at cryogenic temperature vanishes after several monolayers of CO are cryosorbed on both targets. In this paper we describe the new cryogenic target assembly, the temperature-dependent pressure rise, desorption yield, and gas adsorption measurements.

  12. UV–UV hole burning and IR dip spectroscopy of homophenylalanine by laser desorption supersonic jet technique

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Woon Yong; Ishiuchi, Shun-ichi [Chemical Resources Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503 (Japan); Çarçabal, Pierre [Institut des Sciences Moléculaires d’Orsay, CNRS, Université Paris Sud XI, Bâtiment 210, 91405 Orsay (France); Oba, Hikari [Chemical Resources Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503 (Japan); Fujii, Masaaki, E-mail: mfujii@res.titech.ac.jp [Chemical Resources Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503 (Japan)

    2014-12-05

    Highlights: • Homophenylalanine was measured by laser desorption supersonic jet spectroscopy. • Ten conformers were found by UV–UV hole burning spectroscopy. • The observed conformers were assigned by the combination of UV and IR spectra. • Franck–Condon simulations were employed to assign the flexible molecule. - Abstract: Conformer selected electronic and vibrational spectra of homophenylalanine, phenylalanine analogue molecule, were measured by UV–UV hole burning and IR dip spectroscopy combined with laser desorption technique. 10 conformers were found by UV–UV hole burning spectroscopy and their structures were assigned by IR dip and UV absorption spectra with aid of quantum chemical calculations in both S{sub 0} and S{sub 1}. This study shows that the combination of simulated IR and UV spectra is powerful to assign flexible molecules.

  13. TiO(2) printed aluminum foil: single-use film for a laser desorption/ionization target plate.

    Science.gov (United States)

    Bi, Hongyan; Qiao, Liang; Busnel, Jean-Marc; Devaud, Valerie; Liu, Baohong; Girault, Hubert H

    2009-02-01

    Single-use aluminum foil-based laser desorption/ionization (LDI) target plates have been developed for mass spectrometry (MS) analysis and provide detection results comparable to those of commercial stainless steel plates while offering a convenient way to avoid the time-consuming surface cleaning process. Additionally, arrays of TiO(2) nanoparticle spots are coated on the foil either by screen-printing or rotogravure-printing followed by sintering to form a mesoporous layer spot to act as an anchor for sample deposition. These TiO(2) spots offer further functions to the Al foil, such as matrix-free laser desorption/ionization or specific affinity for in situ enrichment of phosphopeptides. The single-use TiO(2)-Al foils are cheap to produce, easy to use, and well suited for high-throughput proteomics research. They can also be of interest for protein post-translational modifications study.

  14. Direct Analysis of Gold Nanoparticles from Dried Droplets Using Substrate-Assisted Laser Desorption Single Particle-ICPMS.

    Science.gov (United States)

    Benešová, Iva; Dlabková, Kristýna; Zelenák, František; Vaculovič, Tomáš; Kanický, Viktor; Preisler, Jan

    2016-03-01

    Single particle inductively coupled plasma mass spectrometry (SP-ICPMS) has been generally accepted as a powerful tool in the field of nanoanalysis. The method has usually been restricted to direct nanoparticle (NP) introduction using nebulization or microdroplet generation systems. In this work, AuNPs are introduced into ICPMS by substrate-assisted laser desorption (SALD) directly from a suitable absorbing plastic surface using a commercial ablation cell for the first time. In SALD, desorption of individual NPs is mediated using a frequency-quintupled Nd:YAG laser (213 nm) operated at a rather low laser fluence. Conditions including laser fluence, laser beam scan rate, and carrier gas flow rate were optimized in order to gain the highest AuNP transport efficiency and avoid AuNP disintegration within the laser irradiation. The method was demonstrated on a well-characterized reference material, 56 nm AuNPs with a transport efficiency of 61% and commercially available 86 nm AuNPs. Feasibility of our technique for NP detection and characterization is discussed here, and the results are compared with an established technique, nebulizer SP-ICPMS.

  15. Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Identification of Mycobacteria in Routine Clinical Practice: e24720

    National Research Council Canada - National Science Library

    Amel El Khéchine; Carine Couderc; Christophe Flaudrops; Didier Raoult; Michel Drancourt

    2011-01-01

    .... Matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS) has previously been proven to effectively identify mycobacteria grown in high-concentration inocula from collections...

  16. Calibration of matrix-assisted laser desorption/ionization time-of-flight peptide mass fingerprinting spectra

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2007-01-01

    This chapter describes a number of aspects important for calibration of matrix-assisted laser desorption/ionization time-of-flight spectra prior to peptide mass fingerprinting searches. Both multipoint internal calibration and mass defect-based calibration is illustrated. The chapter describes ho...... potential internal calibrants, like tryptic autodigest peptides and keratin-related peptides, can be identified and used for high-precision calibration. Furthermore, the construction of project/user-specific lists of potential calibrants is illustrated....

  17. Application of nanodiamonds in human body fluid analysis by matrix-assisted laser desorption/ionization mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Xianglei Kong

    2008-01-01

    Direct mass spectrometric analysis of complex biological samples is very important and challenging. In this paper, nanodiamonds have been successfully used in matrix-assisted laser desorption/ionization mass spectrometric analysis of human serum and urine. As a practical tool and platform, it can be widely used in the field of humoral proteomics, and it plays a very promising role in clinical diagnosis, including identification of novel disease-associated biomarkers.

  18. Nanoparticle-assisted laser desorption/ionization mass spectrometry: Novel sample preparation methods and nanoparticle screening for plant metabolite imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagnik, Gargey B. [Iowa State Univ., Ames, IA (United States)

    2016-02-19

    The main goal of the presented research is development of nanoparticle based matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS). This dissertation includes the application of previously developed data acquisition methods, development of novel sample preparation methods, application and comparison of novel nanoparticle matrices, and comparison of two nanoparticle matrix application methods for MALDI-MS and MALDI-MS imaging.

  19. Photoionization and Dissociative Photoionization Study of Cholesterol by IR Laser Desorption/Tunable Synchrotron VUV Photoionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yang Pan; Li-dong Zhang; Hui-jun Guo; Hao Yin; Fei Qi

    2009-01-01

    Elementary cholesterol was analyzed with IR laser desorption/tunable synchrotron vacuum ultraviolet photoionization mass spectrometry. An exclusive molecular ion of cholesterol is observed by near threshold single-photon ionization with high efficiency. Fragments are yielded with the increase of photon energy. The structures of various fragments are determined with commercial electron ionization time-of-flight mass spectrometry. Dominant fragmentation pathways are discussed in detail with the aid of ab initio calculations.

  20. Black phosphorus-assisted laser desorption ionization mass spectrometry for the determination of low-molecular-weight compounds in biofluids.

    Science.gov (United States)

    He, Xiao-Mei; Ding, Jun; Yu, Lei; Hussain, Dilshad; Feng, Yu-Qi

    2016-09-01

    Quantitative analysis of small molecules by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been a challenging task due to matrix-derived interferences in low m/z region and poor reproducibility of MS signal response. In this study, we developed an approach by applying black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix for the quantitative analysis of small molecules for the first time. Black phosphorus-assisted laser desorption/ionization mass spectrometry (BP/ALDI-MS) showed clear background and exhibited superior detection sensitivity toward quaternary ammonium compounds compared to carbon-based materials. By combining stable isotope labeling (SIL) strategy with BP/ALDI-MS (SIL-BP/ALDI-MS), a variety of analytes labeled with quaternary ammonium group were sensitively detected. Moreover, the isotope-labeled forms of analytes also served as internal standards, which broadened the analyte coverage of BP/ALDI-MS and improved the reproducibility of MS signals. Based on these advantages, a reliable method for quantitative analysis of aldehydes from complex biological samples (saliva, urine, and serum) was successfully established. Good linearities were obtained for five aldehydes in the range of 0.1-20.0 μM with correlation coefficients (R (2)) larger than 0.9928. The LODs were found to be 20 to 100 nM. Reproducibility of the method was obtained with intra-day and inter-day relative standard deviations (RSDs) less than 10.4 %, and the recoveries in saliva samples ranged from 91.4 to 117.1 %. Taken together, the proposed SIL-BP/ALDI-MS strategy has proved to be a reliable tool for quantitative analysis of aldehydes from complex samples. Graphical Abstract An approach for the determination of small molecules was developed by using black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix.

  1. Photoionization and Dissociative Photoionization Study of Cholesterol by IR Laser Desorption/Tunable Synchrotron VUV Photoionization Mass Spectrometry

    Science.gov (United States)

    Pan, Yang; Zhang, Li-dong; Guo, Hui-jun; Yin, Hao; Qi, Fei

    2009-04-01

    Elementary cholesterol was analyzed with IR laser desorption/tunable synchrotron vacuum ultraviolet photoionization mass spectrometry. An exclusive molecular ion of cholesterol is observed by near threshold single-photon ionization with high efficiency. Fragments are yielded with the increase of photon energy. The structures of various fragments are determined with commercial electron ionization time-of-flight mass spectrometry. Dominant fragmentation pathways are discussed in detail with the aid of ab initio calculations.

  2. Overview literature on matrix assisted laser desorption ionization mass spectroscopy (MALDI MS): basics and its applications in characterizing polymeric materials

    Indian Academy of Sciences (India)

    R N Jagtap; A H Ambre

    2005-10-01

    Matrix assisted laser desorption ionization mass spectroscopy (MALDI MS) is a technique which allows the measurement of molecular mass > 200,000 Daltons by ionization and vapourization without degradation. This technique is useful for the mass analysis of synthetic polymers, which have very low volatility. The basic principles of and its applications for polymer characterization have been discussed in this paper. In addition, the possibilities of combining MALDI MS with chromatographic and other analytical techniques have also been discussed.

  3. Efficient laser desorption ionization mass spectrometry of polycyclic aromatic hydrocarbons using excitation energy transfer from anthracene

    Energy Technology Data Exchange (ETDEWEB)

    Fujimori, Kensuke [Department of Chemistry, Graduate School of Science and Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo 192-0397 (Japan); Fujino, Tatsuya, E-mail: fujino@tmu.ac.jp [Department of Chemistry, Graduate School of Science and Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo 192-0397 (Japan)

    2013-06-20

    Highlights: ► Femtomolar detection of PAHs such as perylene and benzopyrene was achieved. ► Photoexcited anthracene molecules transferred their energy to PAHs. ► Electronically excited PAHs were then excited to be ions. ► Two-photon ionization process was necessary to complete the ionization process. ► The number of defect sites could be reduced by the annealing procedure. - Abstract: Polycyclic aromatic hydrocarbons (PAHs), such as perylene and benzopyrene, doped at amounts on the order of femtomol (∼10{sup −15} mol) in anthracene crystals could be detected by laser desorption ionization mass spectrometry. Sensitivity was roughly 10{sup 3} times higher than that of LDI method in our experimental conditions. It was revealed from the excitation power dependence of the peak intensity of PAHs on the mass spectra that two-photon excitation in one UV pulse was necessary to complete the ionization process. It was also clarified that the number of defect sites that trap excitons generated in anthracene crystals could be reduced by the annealing procedure, by which an efficient energy transfer between anthracene and PAHs became possible.

  4. Study of ionization process of matrix molecules in matrix-assisted laser desorption ionization

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Kazumasa; Sato, Asami; Hashimoto, Kenro; Fujino, Tatsuya, E-mail: fujino@tmu.ac.jp

    2013-06-20

    Highlights: ► Proton transfer and adduction reaction of matrix in MALDI were studied. ► Hydroxyl group forming intramolecular hydrogen bond was related to the ionization. ► Intramolecular proton transfer in the electronic excited state was the initial step. ► Non-volatile analytes stabilized protonated matrix in the ground state. ► A possible mechanism, “analyte support mechanism”, has been proposed. - Abstract: Proton transfer and adduction reaction of matrix molecules in matrix-assisted laser desorption ionization were studied. By using 2,4,6-trihydroxyacetophenone (THAP), 2,5-dihydroxybenzoic acid (DHBA), and their related compounds in which the position of a hydroxyl group is different, it was clarified that a hydroxyl group forming an intramolecular hydrogen bond is related to the ionization of matrix molecules. Intramolecular proton transfer in the electronic excited state of the matrix and subsequent proton adduction from a surrounding solvent to the charge-separated matrix are the initial steps for the ionization of matrix molecules. Nanosecond pump–probe NIR–UV mass spectrometry confirmed that the existence of analyte molecules having large dipole moment in their structures is necessary for the stabilization of [matrix + H]{sup +} in the electronic ground state.

  5. Developments and Applications of Electrophoresis and Small Molecule Laser Desorption Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hui [Iowa State Univ., Ames, IA (United States)

    2007-01-01

    Ultra-sensitive native fluorescence detection of proteins with miniaturized one- and two-dimensional polyacrylamide gel electrophoresis was achieved with laser side-entry excitation, which provides both high excitation power and low background level. The detection limit for R-phycoerythrin protein spots in 1-D SDS-PAGE was as low as 15 fg, which corresponds to 40 thousand molecules only. The average detection limit of six standard native proteins was 5 pg per band and the dynamic range spanned more than 3 orders of magnitude. Approximately 150 protein spots from 30 ng of total Escherichia coli extraction were detected on a 0.8 cm x 1 cm gel in two-dimensional separation. Estrogen-DNA adducts as 4-OHE1(E2)-1-N3Ade and 4-OHEI(E2)-2-NacCys were hypothesized as early risk assessment of prostate and breast cancers. Capillary electrophoresis, luminescence/absorption spectroscopy and LC-MS were used to characterize and detect these adducts. Monoclonal antibodies against each individual adduct were developed and used to enrich such compounds from urine samples of prostate and breast cancer patients as well as healthy people. Adduct 4-OHE1-1-N3Ade was detected at much higher level in urine from subjects with prostate cancer patients compared to healthy males. The same adduct and 4-OHEI-2-NacCys were also detected at a much higher level in urine from a woman with breast carcinoma than samples from healthy controls. These two DNA adducts may serve as novel biomarkers for early diagnostic of cancers. The adsorption properties of R-phycoerythrin (RPE), on the fused-silica surface were studied using capillary electrophoresis (CE) and single molecule spectroscopy. The band shapes and migration times were measured in CE. Adsorption and desorption events were recorded at the single-molecule level by imaging of the evanescent-field layer using total internal reflection. The adsorbed RPE molecules on the fused-silica prism surface were

  6. Nanoporous GaN-Ag composite materials prepared by metal-assisted electroless etching for direct laser desorption-ionization mass spectrometry.

    Science.gov (United States)

    Nie, Bei; Duan, Barrett K; Bohn, Paul W

    2013-07-10

    Three-dimensional nanoporous gallium nitride(PGaN) produced by metal-assisted electroless etching is chemically embedded with silver nanoparticles via electroless deposition, forming a metallized semiconductor membrane with large surface area and nanoscale metal features. A new application utilizing the unique chemical and morphological features of these composite nanostructures is described here, laser induced desorption-ionization(LDI) of biomolecules(e.g., cholesterol and nucleotides) for direct mass analysis, without use of additional organic matrix. Although PGaN itself is a poor matrix for direct LDI mass spectrometry, the combination of Ag and PGaN greatly improves ion signals relative to PGaN or Ag nanostructure surfaces alone. This behavior is attributed to the combination of strong UV absorption, enhanced surface area, and favorable thermal properties of PGaN. Importantly, Ag-PGaN is shown to facilitate the formation of Ag adduct ions in some cases, for example adenine, where adducts are not observed from either porous anodic aluminum membranes or surfaces presenting Ag nanoparticles in isolation. Nanopore-embedded Ag nanostructures serve a dual role: as cationization agents and to assist thermal desorption under UV laser irradiation. The results reported here suggest that the combination of Ag nanostructures embedded in PGaN has the capacity for high quality matrix-free LDI mass analysis.

  7. Enhanced capabilities for imaging gangliosides in murine brain with matrix-assisted laser desorption/ionization and desorption electrospray ionization mass spectrometry coupled to ion mobility separation.

    Science.gov (United States)

    Škrášková, Karolina; Claude, Emmanuelle; Jones, Emrys A; Towers, Mark; Ellis, Shane R; Heeren, Ron M A

    2016-07-15

    The increased interest in lipidomics calls for improved yet simplified methods of lipid analysis. Over the past two decades, mass spectrometry imaging (MSI) has been established as a powerful technique for the analysis of molecular distribution of a variety of compounds across tissue surfaces. Matrix-assisted laser desorption/ionization (MALDI) MSI is widely used to study the spatial distribution of common lipids. However, a thorough sample preparation and necessity of vacuum for efficient ionization might hamper its use for high-throughput lipid analysis. Desorption electrospray ionization (DESI) is a relatively young MS technique. In DESI, ionization of molecules occurs under ambient conditions, which alleviates sample preparation. Moreover, DESI does not require the application of an external matrix, making the detection of low mass species more feasible due to the lack of chemical matrix background. However, irrespective of the ionization method, the final information obtained during an MSI experiment is very complex and its analysis becomes challenging. It was shown that coupling MSI to ion mobility separation (IMS) simplifies imaging data interpretation. Here we employed DESI and MALDI MSI for a lipidomic analysis of the murine brain using the same IMS-enabled instrument. We report for the first time on the DESI IMS-MSI of multiply sialylated ganglioside species, as well as their acetylated versions, which we detected directly from the murine brain tissue. We show that poly-sialylated gangliosides can be imaged as multiply charged ions using DESI, while they are clearly separated from the rest of the lipid classes based on their charge state using ion mobility. This represents a major improvement in MSI of intact fragile lipid species. We additionally show that complementary lipid information is reached under particular conditions when DESI is compared to MALDI MSI.

  8. Engineering matrix-free laser desorption ionization mass spectrometry using glancing angle deposition films.

    Science.gov (United States)

    Singh, Reshma; Bezuidenhout, Louis W; Jemere, Abebaw; Wang, Zhen; Brett, Michael; Harrison, D Jed

    2017-04-15

    Thin, nanoporous films fabricated using Glancing Angle Deposition (GLAD) technology are demonstrated for solid matrix laser desorption/ionization mass spectrometry (SMALDI-MS). GLAD allows facile engineering of nanoporosity, film thickness, post alignment, and material composition, as demonstrated here by the fabrication of Co-GLAD and Si-GLAD films for SMALDI, and by exploration of the SMALDI performance as a function of thickness, post density, and angle of the post relative to surface normal. GLAD films were prepared by electron beam evaporation onto silicon substrates, using steep angles of incidence for the vacuum deposition, with computer controlled substrate rotation. LDI from the GLAD films was evaluated using an MDS-Sciex time-of-flight (TOF) MALDI mass spectrometer. Co-GLAD films give a limit of quantitation of 6 fmol for complex carbohydrate derivatives, and slanted-post Si-GLAD films show up to three times higher sensitivity than vertical post structures. Reproducibility of both Si and Co films is much higher than conventional MALDI methods for m/z below at least 2100 Da. Both reproducibility and detection limits are comparable to or better than other nano-structured materials. Co-GLAD films are significantly better in performance than Co powders or Co thin films on silicon substrates previously evaluated. The flexibility of GLAD for thin film fabrication of LDI materials is demonstrated by the range of nanoporous materials that can be grown, and the fine control over structural conformation, thickness and porosity. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Optimising the Use of TRIzol-extracted Proteins in Surface Enhanced Laser Desorption/ Ionization (SELDI Analysis

    Directory of Open Access Journals (Sweden)

    Perlaky Laszlo

    2006-03-01

    Full Text Available Abstract Background Research with clinical specimens is always hampered by the limited availability of relevant samples, necessitating the use of a single sample for multiple assays. TRIzol is a common reagent for RNA extraction, but DNA and protein fractions can also be used for other studies. However, little is known about using TRIzol-extracted proteins in proteomic research, partly because proteins extracted from TRIzol are very resistant to solubilization. Results To facilitate the use of TRIzol-extracted proteins, we first compared the ability of four different common solubilizing reagents to solubilize the TRIzol-extracted proteins from an osteosarcoma cell line, U2-OS. Then we analyzed the solubilized proteins by Surface Enhanced Laser Desorption/ Ionization technique (SELDI. The results showed that solubilization of TRIzol-extracted proteins with 9.5 M Urea and 2% CHAPS ([3-[(3-cholamidopropyl-dimethylammonio]propanesulfonate] (UREA-CHAPS was significantly better than the standard 1% SDS in terms of solubilization efficiency and the number of detectable ion peaks. Using three different types of SELDI arrays (CM10, H50, and IMAC-Cu, we demonstrated that peak detection with proteins solubilized by UREA-CHAPS was reproducible (r > 0.9. Further SELDI analysis indicated that the number of ion peaks detected in TRIzol-extracted proteins was comparable to a direct extraction method, suggesting many proteins still remain in the TRIzol protein fraction. Conclusion Our results suggest that UREA-CHAPS performed very well in solubilizing TRIzol-extracted proteins for SELDI applications. Protein fractions left over after TRIzol RNA extraction could be a valuable but neglected source for proteomic or biochemical analysis when additional samples are not available.

  10. Depth profiling of inks in authentic and counterfeit banknotes by electrospray laser desorption ionization/mass spectrometry.

    Science.gov (United States)

    Kao, Yi-Ying; Cheng, Sy-Chyi; Cheng, Chu-Nian; Shiea, Jentaie

    2016-01-01

    Electrospray laser desorption ionization is an ambient ionization technique that generates neutrals via laser desorption and ionizes those neutrals in an electrospray plume and was utilized to characterize inks in different layers of copy paper and banknotes of various currencies. Depth profiling of inks was performed on overlapping color bands on copy paper by repeatedly scanning the line with a pulsed laser beam operated at a fixed energy. The molecules in the ink on a banknote were desorbed by irradiating the banknote surface with a laser beam operated at different energies, with results indicating that different ions were detected at different depths. The analysis of authentic $US100, $100 RMB and $1000 NTD banknotes indicated that ions detected in 'color-shifting' and 'typography' regions were significantly different. Additionally, the abundances of some ions dramatically changed with the depth of the aforementioned regions. This approach was used to distinguish authentic $1000 NTD banknotes from counterfeits. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Desorption of H atoms from graphite (0001) using XUV free electron laser pulses

    DEFF Research Database (Denmark)

    Siemer, B.; Olsen, Thomas; Hoger, T.;

    2010-01-01

    , and identifies the highest vibrational state in the adsorbate potential as a major source for the slow atoms. It is evident that multiple electron scattering processes are required for this desorption. A direct electronic excitation of a repulsive hydrogen-carbon bond seems not to be important.......The desorption of neutral H atoms from graphite with femtosecond XUV pulses is reported. The velocity distribution of the atoms peaks at extremely low kinetic energies. A DFT-based electron scattering calculation traces this distribution to desorption out of specific adsorption sites on graphite...

  12. An ultraviolet/infrared matrix-assisted laser desorption ionization sample stage integrating scanning knife-edge and slit devices for laser beam analysis.

    Science.gov (United States)

    Soltwisch, Jens; Dreisewerd, Klaus

    2011-05-15

    A sample stage is described that allows the on-line analysis of laser intensity profiles and spot sizes directly in the ion source of a matrix-assisted laser desorption ionization (MALDI) mass spectrometer. The detector uses either a scanning knife-edge or a narrow slit in combination with diffusing disks for scattering of photons and a pyroelectric sensor for recording the light pulses. The setup was integrated into the sample holder of a oMALDI2(TM) ion source (AB Sciex) and allows parallel analysis of UV- and IR-laser beams at typical UV-/IR-MALDI laser fluences. The concept could be especially useful for a precise control of the laser spot size in MALDI imaging applications. Copyright © 2011 John Wiley & Sons, Ltd.

  13. High-Resolution Live-Cell Imaging and Analysis by Laser Desorption/Ionization Droplet Delivery Mass Spectrometry.

    Science.gov (United States)

    Lee, Jae Kyoo; Jansson, Erik T; Nam, Hong Gil; Zare, Richard N

    2016-05-17

    We have developed a new ambient-ionization mass spectrometric technique named laser desorption/ionization droplet delivery mass spectrometry (LDIDD-MS). LDIDD-MS permits high-resolution, high-sensitivity imaging of tissue samples as well as measurements of both single-cell apoptosis and live-cell exocytosis. A pulsed (15 Hz) UV laser beam (266 nm) is focused on a surface covered with target analytes to trigger their desorption and ionization. A spray of liquid droplets is simultaneously directed onto the laser-focused surface region to capture the ionized analytes and deliver them to a mass spectrometer. The approach of rapid and effective capturing of molecules after laser desorption/ionization allows the limit of detection for the amino acid lysine to be as low as 2 amol under ambient ionization conditions. Two-dimensional maps of the desorbed/ionized species are recorded by moving the sample on an XY translational stage. The spatial resolution for imaging with LDIDD-MS was determined to be 2.4 μm for an ink-printed pattern and 3 μm for mouse brain tissue. We applied LDIDD-MS to single-cell analysis of apoptotic HEK cells. Differences were observed in the profiles of fatty acids and lipids between healthy HEK cells and those undergoing apoptosis. We observed upregulation of phosphatidylcholine (PC) with a relatively shorter carbon chain length and downregulation of PC with a relatively longer carbon chain length. We also applied LDIDD-MS for a real-time direct measurements of live-cell exocytosis. The catecholamine dopamine and trace amines (phenethylamine and tyramine) were detected from live PC12 cells without damaging them.

  14. Laser induced structural vibration

    Science.gov (United States)

    Koss, L. L.; Tobin, R. C.

    1983-01-01

    A technique is described for exciting structural vibration by using a focussed laser beam to vaporize material from a target attached to the structure. The rapid ejection of material results in an impulsive reaction to the target which is transmitted to the structure. The method has been studied with a Nd: glass laser, operated in the long pulse mode, in combination with a bismuth target attached in turn to a ballistic pendulum and cantilever beam. The specific mechanical energy was found to be proportional to the laser pulse energy raised to a power in the range 2.5-2.9. The highest efficiency of energy transfer achieved for the first vibrational mode of the cantilever was about 2 millipercent for the maximum laser pulse energy used, 1.5 J, the signal to noise ratio then being about 40 dB.

  15. Structural features of lipoarabinomannan from Mycobacterium bovis BCG. Determination of molecular mass by laser desorption mass spectrometry.

    Science.gov (United States)

    Venisse, A; Berjeaud, J M; Chaurand, P; Gilleron, M; Puzo, G

    1993-06-15

    It was recently shown that mycobacterial lipoarabinomannan (LAM) can be classified into two types (Chatterjee, D., Lowell, K., Rivoire B., McNeil M. R., and Brennan, P. J. (1992) J. Biol. Chem. 267, 6234-6239) according to the presence or absence of mannosyl residues (Manp) located at the nonreducing end of the oligoarabinosyl side chains. These two types of LAM were found in a pathogenic Mycobacterium tuberculosis strain and in an avirulent M. tuberculosis strain, respectively, suggesting that LAM with Manp characterizes virulent and "disease-inducing strains." We now report the structure of the LAM from Mycobacterium bovis Bacille Calmette-Guérin (BCG) strain Pasteur, largely used throughout the world as vaccine against tuberculosis. Using an up-to-date analytical approach, we found that the LAM of M. bovis BCG belongs to the class of LAMs capped with Manp. By means of two-dimensional homonuclear and heteronuclear scalar coupling NMR analysis and methylation data, the sugar spin system assignments were partially established, revealing that the LAM contained two types of terminal Manp and 2-O-linked Manp. From the following four-step process: (i) partial hydrolysis of deacylated LAM (dLAM), (ii) oligosaccharide derivatization with aminobenzoic ethyl ester, (iii) HPLC purification, (iv) FAB/MS-MS analysis; it was shown that the dimannosyl unit alpha-D-Manp-(1-->2)-alpha-D-Manp is the major residue capping the termini of the arabinan of the LAM. In this report, LAM molecular mass determination was established using matrix-assisted UV-laser desorption/ionization mass spectrometry which reveals that the LAM molecular mass is around 17.4 kDa. The similarity of the LAM structures between M. bovis BCG and M. tuberculosis H37Rv is discussed in regard to their function in the immunopathology of mycobacterial infection.

  16. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  17. A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

    Science.gov (United States)

    Arevalo, Ricardo, Jr.; Coyle, Barry; Paulios, Demetrios; Stysley, Paul; Feng, Steve; Getty, Stephanie; Binkerhoff, William

    2015-01-01

    Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

  18. On the determination of molecular weight distributions of asphaltenes and their aggregates in laser desorption ionization experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hortal, A.R.; Martinez-Haya, B.; Lobato, M.D.; Pedrosa, J.M.; Lago, S. [University of Pablo Olavide, Seville (Spain)

    2006-07-15

    Molecular weight distributions (MWD) of asphaltenes and their aggregates have been investigated in laser desorption ionization (LDI) mass spectrometric experiments. A systematic investigation of the dependence of the measured MIND on the asphaltene sample density and on the laser pulse energy allows the assignment of most probable molecular weights within 300-500 amu and average molecular weights of 800-1000 amu for the monomeric asphaltenes, as well as for the estimation of the contribution from asphaltene clusters in typical LDI measurements. The results serve to reconcile the existing controversy between earlier mass spectrometric characterizations of asphaltenes based on laser desorption techniques by different groups. Furthermore, the MWD measurements performed on particularly dense samples yield an additional differentiated broad band peaking around 9000-10,000 amu and extending over 20,000 amu, not observed previously in LDI experiments, thereby revealing a strong propensity of the asphaltenes to form clusters with specific aggregation numbers, which is in qualitative agreement with previous theoretical predictions and with the interpretation of measurements performed with other techniques.

  19. Functionalization of silicon nanowire arrays by silver nanoparticles for the laser desorption ionization mass spectrometry analysis of vegetable oils.

    Science.gov (United States)

    Picca, Rosaria Anna; Calvano, Cosima Damiana; Lo Faro, Maria Josè; Fazio, Barbara; Trusso, Sebastiano; Ossi, Paolo Maria; Neri, Fortunato; D'Andrea, Cristiano; Irrera, Alessia; Cioffi, Nicola

    2016-09-01

    In this work, novel hybrid nanostructured surfaces, consisting of dense arrays of silicon nanowires (SiNWs) functionalized by Ag nanoparticles (AgNP/SiNWs), were used for the laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS) analysis of some typical unsaturated food components (e.g. squalene, oleic acid) to assess their MS performance. The synthesis of the novel platforms is an easy, cost-effective process based on the maskless wet-etching preparation at room temperature of SiNWs followed by their decoration with AgNPs, produced by pulsed laser deposition. No particular surface pretreatment or addition of organic matrixes/ionizers was necessary. Moreover, oil extracts (e.g. extra virgin olive oil, peanut oil) could be investigated on AgNP/SiNWs surfaces, revealing their different MS profiles. It was shown that such substrates operate at reduced laser energy, typically generating intense silver cluster ions and analyte adducts. A comparison with bare SiNWs was also performed, indicating the importance of AgNP density on NW surface. In this case, desorption/ionization on silicon was invoked as probable LDI mechanism. Finally, the influence of SiNW length and surface composition on MS results was assessed. The combination of typical properties of SiNWs (hydrophobicity, antireflectivity) with ionization ability of metal NPs can be a valid methodology for the further development of nanostructured surfaces in LDI-TOF MS applications. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Quantification of Carbohydrates and Related Materials Using Sodium Ion Adducts Produced by Matrix-Assisted Laser Desorption Ionization

    Science.gov (United States)

    Ahn, Sung Hee; Park, Kyung Man; Moon, Jeong Hee; Lee, Seong Hoon; Kim, Myung Soo

    2016-11-01

    The utility of sodium ion adducts produced by matrix-assisted laser desorption ionization for the quantification of analytes with multiple oxygen atoms was evaluated. Uses of homogeneous solid samples and temperature control allowed the acquisition of reproducible spectra. The method resulted in a direct proportionality between the ion abundance ratio I([A + Na]+)/I([M + Na]+) and the analyte concentration, which could be used as a calibration curve. This was demonstrated for carbohydrates, glycans, and polyether diols with dynamic range exceeding three orders of magnitude.

  1. Pigments and proteins in green bacterial chlorosomes studied by matrix-assisted laser desorption ionization mass spectrometry

    DEFF Research Database (Denmark)

    Persson, S; Sönksen, C P; Frigaard, N-U

    2000-01-01

    homologs in a small amount of green bacterial cells. In addition to information on pigments, the MALDI spectra also contained peaks from chlorosome proteins. Thus we have been able with high precision to confirm the molecular masses of the chlorosome proteins CsmA and CsmE which have been previously......We have used matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for mass determination of pigments and proteins in chlorosomes, the light-harvesting organelles from the photosynthetic green sulfur bacterium Chlorobium tepidum. By applying a small volume (1...

  2. Pigments and proteins in green bacterial chlorosomes studied by matrix-assisted laser desorption ionization mass spectrometry

    DEFF Research Database (Denmark)

    Persson, S; Sönksen, C P; Frigaard, N U

    2000-01-01

    We have used matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for mass determination of pigments and proteins in chlorosomes, the light-harvesting organelles from the photosynthetic green sulfur bacterium Chlorobium tepidum. By applying a small volume (1...... homologs in a small amount of green bacterial cells. In addition to information on pigments, the MALDI spectra also contained peaks from chlorosome proteins. Thus we have been able with high precision to confirm the molecular masses of the chlorosome proteins CsmA and CsmE which have been previously...

  3. Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory.

    Science.gov (United States)

    Kok, Jen; Chen, Sharon C A; Dwyer, Dominic E; Iredell, Jonathan R

    2013-01-01

    The integration of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) into many clinical microbiology laboratories has revolutionised routine pathogen identification. MALDI-TOF MS complements and has good potential to replace existing phenotypic identification methods. Results are available in a more clinically relevant timeframe, particularly in bacteraemic septic shock. Novel applications include strain typing and the detection of antimicrobial resistance, but these are not widely used. This review discusses the technical aspects, current applications, and limitations of MALDI-TOF MS.

  4. Authenticity assessment of beef origin by principal component analysis of matrix-assisted laser desorption/ionization mass spectrometric data.

    Science.gov (United States)

    Zaima, Nobuhiro; Goto-Inoue, Naoko; Hayasaka, Takahiro; Enomoto, Hirofumi; Setou, Mitsutoshi

    2011-06-01

    It has become necessary to assess the authenticity of beef origin because of concerns regarding human health hazards. In this study, we used a metabolomic approach involving matrix-assisted laser desorption/ionization imaging mass spectrometry to assess the authenticity of beef origin. Highly accurate data were obtained for samples of extracted lipids from beef of different origin; the samples were grouped according to their origin. The analysis of extracted lipids in this study ended within 10 min, suggesting this approach can be used as a simple authenticity assessment before a definitive identification by isotope analysis.

  5. Detection of Radical Adducts with Small Molecular Weights by Matrix-Assisted Laser Desorption/Ionization with Fourier Transform Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    TIAN,Yao-Wei; SUN,Shi-Hao; XIE,Jian-Ping; ZONG,Yong-Li; NIE,Cong; GUO,Yin-Long

    2007-01-01

    As an alternative method, matrix-assisted laser desorption/ionization with Fourier transform mass spectrometry (MALDI-FTMS) has been successfully used to detect and identify free radical adducts with small molecular weights of hydroxyl and 2-cyano-2-propyl radicals trapped with 5,5-dimethylpyrroline N-oxide (DMPO). The detection and identification by MS/MS experiments using sustained offresonance irradiation collision-induced dissociation (SORI-CID) of [(DMPO+·OH-·H)+H+] (m/z 130.0868) and [DMPO+2 ·CH(CH3)2CN+H+] (m/z 250.1917) have demonstrated that MALDI-FTMS could be an effective method for detection and identification of free radical adducts. Other radical adducts have been also detected and identified. The approach of MALDI-FTMS is simple, fast, and sensitive which has potential for high-throughput analysis.

  6. Treatment of Laser-Induced Retinal Injuries

    Science.gov (United States)

    1989-06-29

    Distribution List (enclosed) bI’TF rruIoN STATEMEN A Approved for publi reljaso Disatbunon Unlimited TREATMENT OF LASER-INDUCED RETINAL INJURIES FINAL...suprathreshold retinal laser lesions II. Subthreshold retinal laser lesions III. Effect of steroid treatment on laser-induced retinal injury Discussion and...In the present study we investigated the effect of corticosteroid treatment of argon laser-induced retinal injury on vitreal accumulation of both

  7. Considerations for quantification of lipids in nerve tissue using matrix-assisted laser desorption/ionization mass spectrometric imaging.

    Science.gov (United States)

    Landgraf, Rachelle R; Garrett, Timothy J; Conaway, Maria C Prieto; Calcutt, Nigel A; Stacpoole, Peter W; Yost, Richard A

    2011-10-30

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging is a technique that provides the ability to identify and characterize endogenous and exogenous compounds spatially within tissue with relatively little sample preparation. While it is a proven methodology for qualitative analysis, little has been reported for its utility in quantitative measurements. In the current work, inherent challenges in MALDI quantification are addressed. Signal response is monitored over successive analyses of a single tissue section to minimize error due to variability in the laser, matrix application, and sample inhomogeneity. Methods for the application of an internal standard to tissue sections are evaluated and used to quantify endogenous lipids in nerve tissue. A precision of 5% or less standard error was achieved, illustrating that MALDI imaging offers a reliable means of in situ quantification for microgram-sized samples and requires minimal sample preparation.

  8. Ion-to-Neutral Ratios and Thermal Proton Transfer in Matrix-Assisted Laser Desorption/Ionization.

    Science.gov (United States)

    Lu, I-Chung; Chu, Kuan Yu; Lin, Chih-Yuan; Wu, Shang-Yun; Dyakov, Yuri A; Chen, Jien-Lian; Gray-Weale, Angus; Lee, Yuan-Tseh; Ni, Chi-Kung

    2015-07-01

    The ion-to-neutral ratios of four commonly used solid matrices, α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (2,5-DHB), sinapinic acid (SA), and ferulic acid (FA) in matrix-assisted laser desorption/ionization (MALDI) at 355 nm are reported. Ions are measured using a time-of-flight mass spectrometer combined with a time-sliced ion imaging detector. Neutrals are measured using a rotatable quadrupole mass spectrometer. The ion-to-neutral ratios of CHCA are three orders of magnitude larger than those of the other matrices at the same laser fluence. The ion-to-neutral ratios predicted using the thermal proton transfer model are similar to the experimental measurements, indicating that thermal proton transfer reactions play a major role in generating ions in ultraviolet-MALDI.

  9. Laser desorption/ionization mass spectrometry for direct profiling and imaging of small molecules from raw biological materials

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sangwon [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    Matrix-assisted laser desorption/ionization(MALDI) mass spectrometry(MS) has been widely used for analysis of biological molecules, especially macromolecules such as proteins. However, MALDI MS has a problem in small molecule (less than 1 kDa) analysis because of the signal saturation by organic matrixes in the low mass region. In imaging MS (IMS), inhomogeneous surface formation due to the co-crystallization process by organic MALDI matrixes limits the spatial resolution of the mass spectral image. Therefore, to make laser desorption/ionization (LDI) MS more suitable for mass spectral profiling and imaging of small molecules directly from raw biological tissues, LDI MS protocols with various alternative assisting materials were developed and applied to many biological systems of interest. Colloidal graphite was used as a matrix for IMS of small molecules for the first time and methodologies for analyses of small metabolites in rat brain tissues, fruits, and plant tissues were developed. With rat brain tissues, the signal enhancement for cerebroside species by colloidal graphite was observed and images of cerebrosides were successfully generated by IMS. In addition, separation of isobaric lipid ions was performed by imaging tandem MS. Directly from Arabidopsis flowers, flavonoids were successfully profiled and heterogeneous distribution of flavonoids in petals was observed for the first time by graphite-assisted LDI(GALDI) IMS.

  10. Detection of trace organics in Mars analog samples containing perchlorate by laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Li, Xiang; Danell, Ryan M; Brinckerhoff, William B; Pinnick, Veronica T; van Amerom, Friso; Arevalo, Ricardo D; Getty, Stephanie A; Mahaffy, Paul R; Steininger, Harald; Goesmann, Fred

    2015-02-01

    Evidence from recent Mars missions indicates the presence of perchlorate salts up to 1 wt % level in the near-surface materials. Mixed perchlorates and other oxychlorine species may complicate the detection of organic molecules in bulk martian samples when using pyrolysis techniques. To address this analytical challenge, we report here results of laboratory measurements with laser desorption mass spectrometry, including analyses performed on both commercial and Mars Organic Molecule Analyzer (MOMA) breadboard instruments. We demonstrate that the detection of nonvolatile organics in selected spiked mineral-matrix materials by laser desorption/ionization (LDI) mass spectrometry is not inhibited by the presence of up to 1 wt % perchlorate salt. The organics in the sample are not significantly degraded or combusted in the LDI process, and the parent molecular ion is retained in the mass spectrum. The LDI technique provides distinct potential benefits for the detection of organics in situ on the martian surface and has the potential to aid in the search for signs of life on Mars.

  11. Matrix-Free UV-Laser Desorption Ionization Mass Spectrometry as a Versatile Approach for Accelerating Dereplication Studies on Lichens.

    Science.gov (United States)

    Le Pogam, Pierre; Schinkovitz, Andreas; Legouin, Béatrice; Le Lamer, Anne-Cécile; Boustie, Joël; Richomme, Pascal

    2015-10-20

    The present study examined the suitability of laser desorption/ionization time-of-flight mass spectrometry (LDI-MS) for the rapid chemical fingerprinting of lichen extracts. Lichens are known to produce a wide array of secondary metabolites. Most of these compounds are unique to the symbiotic condition but some can be found in many species. Therefore, dereplication, that is, the rapid identification of known compounds within a complex mixture is crucial in the search for novel natural products. Over the past decade, significant advances were made in analytical techniques and profiling methods specifically adapted to crude lichen extracts, but LDI-MS has never been applied in this context. However, most classes of lichen metabolites have UV chromophores, which are quite similar to commercial matrix molecules used in matrix-assisted laser desorption ionization (MALDI). It is consequently postulated that these molecules could be directly detectable by matrix-free LDI-MS. The present study evaluated the versatility of this technique by investigating the LDI properties of a vast array of single lichen metabolites as well as lichen extracts of known chemical composition. Results from the LDI experiments were compared with those obtained by direct ESI-MS detection as well as LC-ESI-MS. It was shown that LDI ionization leads to strong molecular ion formation with little fragmentation, thus, facilitating straightforward spectra interpretation and representing a valuable alternative to time-consuming LC-MS analysis.

  12. Furoic and mefenamic acids as new matrices for matrix assisted laser desorption/ionization-(MALDI)-mass spectrometry.

    Science.gov (United States)

    Abdelhamid, Hani Nasser; Wu, Hui-Fen

    2013-10-15

    The present study introduces two novel organic matrices for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the analysis of small molecules. The first matrix is "2-amino-4,5-diphenylfuran-3-carboxylic acid" (also called furoic acid, FA) which was synthesized and then characterized by ultraviolet (UV), infrared (FTIR), nuclear magnetic resonance NMR ((1)H and (13)C) and mass spectrometry. The compound has organic semiconductor properties and exhibits intense UV-absorption which is suitable for the UV-MALDI laser (N2 laser, 337 nm). The second matrix is mefenamic acid (MA). The two matrices can be successfully applied for various classes of compounds including adenosine-5'-triphosphate (ATP, 0.5 µL(10.0 nmol)), spectinomycin (spect, 0.5 µL(14.0 nmol)), glutathione (GSH, 0.5 µL(9.0 nmol)), sulfamethazole (SMT, 0.5 µL(2.0 nmol)) and mixture of peptides gramicidin D (GD, 0.5µL (9.0 nmol)). The two matrices can effectively absorb the laser energy, resulting in excellent desorption/ionization of small molecules. The new matrices offer a significant enhancement of ionization, less fragmentation, few interferences, nice reproducibility, and excellent stability under vacuum. Theoretical calculations of the physical parameters demonstrated increase in polarizability, molar volume and refractivity than the conventional organic matrices which can effectively enhance the proton transfer reactions between the matrices with the analyte molecules. While the reduction in density, surface tension and index of refraction can enhance homogeneity between the two new matrices with the analytes. Due to the sublimation energy of mefenamic acid is (1.2 times) higher than that of the DHB, it is more stable to be used in the vacuum.

  13. Screening of specific proteins in ultraviolet-induced acute damage of human fibroblasts using proteinchip with surface enhanced laser desorption/ ionization time-of-flight mass spectrometry%采用蛋白芯片结合SELDI-TOF-MS技术筛选紫外线照射后皮肤成纤维细胞损伤的特异性蛋白

    Institute of Scientific and Technical Information of China (English)

    闫言; 徐浩翔; 郑艳华; 刘洁; 张建中; 王宝玺

    2015-01-01

    目的 探讨应用蛋白芯片结合表面增强激光解吸离子化飞行时间质谱(SELDI-TOF-MS)技术筛选紫外线照射后皮肤成纤维细胞早期损伤的生物标记的可行性.方法 用弱阳离子交换蛋白芯片(CM10)结合SELDI-TOF-MS技术,检测未照射组、2.5 J/cm2长波紫外线(UVA)照射组和100 mJ/cm2中波紫外线(UVB)照射组正常人真皮成纤维细胞差异表达的蛋白.结果 紫外线照射组与未照射组蛋白质指纹图谱比较,发现10种蛋白表达下降,8种蛋白表达增强.将差异蛋白峰在SWISS-PROT和TREMBLE蛋白数据库中搜索,发现相对分子质量为11 320.1的蛋白峰与人半胱氨酸天冬氨酸蛋白酶-7前驱体(caspase-7 precursor)相匹配;相对分子质量为8 574.3的蛋白峰与细胞色素C氧化酶多肽VIc前体(Cytochrome c oxidase polypeptide VIc precursor)相符.结论 蛋白芯片结合SELDI-TOF-MS技术是一种快速、简便的高通量蛋白质组研究方法,为光损伤研究提供了新的研究平台.%Objective To investigate specific proteins in ultraviolet (UV)-induced acute damage of human fibroblasts using proteinchip with surface enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS).Methods CM10 Proteinchip and SELDI-TOF-MS were used for detecting protein samples of non-irradiated group,UVA (2.5 J/cm2)-irradiated group and UVB (100 mJ/cm2)-irradiated group of normal human fibroblasts.Results Ten protein peaks were down-regulated and 8 protein peaks up-regulated in fibroblasts after UV irradiation.By searching in SWISS-PROT and TREMBLE databases,the peaks of 11 320.1 and 8 574.3 accorded with those of caspase-7 precursor and cytochrome C oxidase polypeptide VIc precursor proteins.Conclusion As a quick and convenient high-throughout proteomic analytic method,SELDI-TOF-MS plus proteinchip offers a unique platform for detecting dermal photodamage.

  14. Laser-induced tobacco protoplast fusion

    Institute of Scientific and Technical Information of China (English)

    李银妹; 关力劼; 楼立人; 崔国强; 姚湲; 王浩威; 操传顺; 鲁润龙; 陈曦

    1999-01-01

    Laser tweezers can manipulate small particles, such as cells and organdies. When coupling them with laser microbeam selective fusion of two tobacco protoplasts containing some chloroplast was achieved. Physical and biological variables that affect laser trapping and laser-induced fusion were also discussed. The results show that the effect of chloroplast content and distribution on the yield of cell fusion is remarkable.

  15. Matrix-enhanced surface-assisted laser desorption/ionization mass spectrometry (ME-SALDI-MS) for mass spectrometry imaging of small molecules.

    Science.gov (United States)

    Brown, Victoria L; Liu, Qiang; He, Lin

    2015-01-01

    Surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS), a parallel technique to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), utilizes inorganic particles or porous surfaces to aid in the desorption/ionization of low-molecular-weight (MW) analytes. As a matrix-free and "soft" LDI approach, SALDI offers the benefit of reduced background noise in the low MW range, allowing for easier detection of biologically significant small MW species. Despite the inherent advantages of SALDI-MS, it has not reached comparable sensitivity levels to MALDI-MS. In relation to mass spectrometry imaging (MSI), intense efforts have been made in order to improve sensitivity and versatility of SALDI-MSI. We describe herein a detailed protocol that utilizes a hybrid LDI method, matrix-enhanced SALDI-MS (ME-SALDI MS), to detect and image low MW species in an imaging mode.

  16. Solvent Separating Secondary Metabolites Directly from Biosynthetic Tissue for Surface-Assisted Laser Desorption Ionisation Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    David Rudd

    2015-03-01

    Full Text Available Marine bioactive metabolites are often heterogeneously expressed in tissues both spatially and over time. Therefore, traditional solvent extraction methods benefit from an understanding of the in situ sites of biosynthesis and storage to deal with heterogeneity and maximize yield. Recently, surface-assisted mass spectrometry (MS methods namely nanostructure-assisted laser desorption ionisation (NALDI and desorption ionisation on porous silicon (DIOS surfaces have been developed to enable the direct detection of low molecular weight metabolites. Since direct tissue NALDI-MS or DIOS-MS produce complex spectra due to the wide variety of other metabolites and fragments present in the low mass range, we report here the use of “on surface” solvent separation directly from mollusc tissue onto nanostructured surfaces for MS analysis, as a mechanism for simplifying data annotation and detecting possible artefacts from compound delocalization during the preparative steps. Water, ethanol, chloroform and hexane selectively extracted a range of choline esters, brominated indoles and lipids from Dicathais orbita hypobranchial tissue imprints. These compounds could be quantified on the nanostructured surfaces by comparison to standard curves generated from the pure compounds. Surface-assisted MS could have broad utility for detecting a broad range of secondary metabolites in complex marine tissue samples.

  17. Global optimization of the infrared matrix-assisted laser desorption electrospray ionization (IR MALDESI) source for mass spectrometry using statistical design of experiments.

    Science.gov (United States)

    Barry, Jeremy A; Muddiman, David C

    2011-12-15

    Design of experiments (DOE) is a systematic and cost-effective approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response can be measured in few experiments. Herein, we describe the use of statistical DOE to improve a few of the analytical figures of merit of the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source for mass spectrometry. In a typical experiment, bovine cytochrome c was ionized via electrospray, and equine cytochrome c was desorbed and ionized by IR-MALDESI such that the ratio of equine:bovine was used as a measure of the ionization efficiency of IR-MALDESI. This response was used to rank the importance of seven source parameters including flow rate, laser fluence, laser repetition rate, ESI emitter to mass spectrometer inlet distance, sample stage height, sample plate voltage, and the sample to mass spectrometer inlet distance. A screening fractional factorial DOE was conducted to designate which of the seven parameters induced the greatest amount of change in the response. These important parameters (flow rate, stage height, sample to mass spectrometer inlet distance, and laser fluence) were then studied at higher resolution using a full factorial DOE to obtain the globally optimized combination of parameter settings. The optimum combination of settings was then compared with our previously determined settings to quantify the degree of improvement in detection limit. The limit of detection for the optimized conditions was approximately 10 attomoles compared with 100 femtomoles for the previous settings, which corresponds to a four orders of magnitude improvement in the detection limit of equine cytochrome c.

  18. Preanalytical and analytical variation of surface-enhanced laser desorption-ionization time-of-flight mass spectrometry of human serum

    DEFF Research Database (Denmark)

    Albrethsen, Jakob; Bøgebo, Rikke; Olsen, Jesper

    2006-01-01

    BACKGROUND: Surface-enhanced laser desorption-ionization time-of-flight (SELDI-TOF) mass spectrometry of human serum is a potential diagnostic tool in human diseases. In the present study, the preanalytical and analytical variation of SELDI-TOF mass spectrometry of serum was assessed in healthy...

  19. Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging for Peptide and Protein Analyses: A Critical Review of On-Tissue Digestion

    NARCIS (Netherlands)

    Cillero-Pastor, B.; Heeren, R.M.A.

    2013-01-01

    Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) has established itself among the plethora of mass spectrometry applications. In the biomedical field, MALDI-MSI is being more frequently recognized as a new method for the discovery of biomarkers and targets of treatme

  20. Identification of Wheat Varieties Using Matrix-assisted Laser Desorption/Ionisation Time-of-flight Mass Spectrometry and an Artificial Neural network

    DEFF Research Database (Denmark)

    Bloch, Helle Aagaard; Kesmir, Can; Petersen, Marianne Kjerstine;

    1999-01-01

    A novel tool for variety identification of wheat (Triticum aestivum L,) has been developed: an artificial neural network (ANN) is used to classify the gliadin fraction analysed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The robustness...

  1. Analysis of Phospholipid Mixtures from Biological Tissues by Matrix-Assisted Laser Desorption and Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS): A Laboratory Experiment

    Science.gov (United States)

    Eibisch, Mandy; Fuchs, Beate; Schiller, Jurgen; Sub, Rosmarie; Teuber, Kristin

    2011-01-01

    Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used to investigate the phospholipid (PL) compositions of tissues and body fluids, often without previous separation of the total mixture into the individual PL classes. Therefore, the questions of whether all PL classes are detectable…

  2. Identification of Fatty Acids, Phospholipids, and Their Oxidation Products Using Matrix-Assisted Laser Desorption Ionization Mass Spectrometry and Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Harmon, Christopher W.; Mang, Stephen A.; Greaves, John; Finlayson-Pitts, Barbara J.

    2010-01-01

    Electrospray ionization mass spectrometry (ESI-MS) and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) have found increasing application in the analysis of biological samples. Using these techniques to solve problems in analytical chemistry should be an essential component of the training of undergraduate chemists. We…

  3. Alkaloid profiling of the Chinese herbal medicine Fuzi by combination of matrix-assisted laser desorption ionization mass spectrometry with liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wang, J.; Heijden, R. van der; Spijksma, G.; Reijmers, T.; Wang, M.; Xu, G.; Hankemeier, T.; Greef, J. van der

    2009-01-01

    A matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) method was developed for the high throughput and robust qualitative profiling of alkaloids in Fuzi-the processed lateral roots of the Chinese herbal medicine Aconitum carmichaeli Debx (A. carmichaeli). After optimization, pow

  4. Differentiation of Raoultella ornithinolytica/planticola and Klebsiella oxytoca clinical isolates by matrix-assisted laser desorption/ionization-time of flight mass spectrometry.

    NARCIS (Netherlands)

    Jong, Eefje de; Jong, A.S. de; Smidts-van den Berg, N.; Rentenaar, R.J.

    2013-01-01

    Ninety-nine clinical isolates previously identified as Klebsiella oxytoca were evaluated using matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). Eight isolates were identified as Raoultella spp., being 5 Raoultella spp. and 3 K. oxytoca, by 16S rRNA sequenc

  5. Analysis of Phospholipid Mixtures from Biological Tissues by Matrix-Assisted Laser Desorption and Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS): A Laboratory Experiment

    Science.gov (United States)

    Eibisch, Mandy; Fuchs, Beate; Schiller, Jurgen; Sub, Rosmarie; Teuber, Kristin

    2011-01-01

    Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used to investigate the phospholipid (PL) compositions of tissues and body fluids, often without previous separation of the total mixture into the individual PL classes. Therefore, the questions of whether all PL classes are detectable…

  6. Identification of Fatty Acids, Phospholipids, and Their Oxidation Products Using Matrix-Assisted Laser Desorption Ionization Mass Spectrometry and Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Harmon, Christopher W.; Mang, Stephen A.; Greaves, John; Finlayson-Pitts, Barbara J.

    2010-01-01

    Electrospray ionization mass spectrometry (ESI-MS) and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) have found increasing application in the analysis of biological samples. Using these techniques to solve problems in analytical chemistry should be an essential component of the training of undergraduate chemists. We…

  7. Differentiation of Clinically Relevant mucorales Rhizopus microsporus and R. arrhizus by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS)

    NARCIS (Netherlands)

    Dolatabadi, S.; Kolecka, A.; Versteeg, Matthijs; de Hoog, Sybren G; Boekhout, Teun

    2015-01-01

    This study addresses the usefulness of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) for reliable identification of the two most frequently occuring clinical species of Rhizopus, namely R. arrhizus with its two varieties arrhizus and delemar and R. micro

  8. Possible evidence of amide bond formation between sinapinic acid and lysine-containing bacterial proteins by matrix-assisted laser desorption/ionization (MALDI) at 355 nm

    Science.gov (United States)

    We previously reported the apparent formation of matrix adducts of 3,5-dimethoxy-4-hydroxy-cinnamic acid (sinapinic acid or SA) via covalent attachment to disulfide bond-containing proteins (HdeA, HdeB and YbgS) from bacterial cell lysates ionized by matrix-assisted laser desorption/ionization (MALD...

  9. Adsorption-desorption induced structural changes of Cu-MOF evidenced by solid state NMR and EPR spectroscopy.

    Science.gov (United States)

    Jiang, Yijiao; Huang, Jun; Kasumaj, Besnik; Jeschke, Gunnar; Hunger, Michael; Mallat, Tamas; Baiker, Alfons

    2009-02-18

    Adsorption-desorption induced structural changes of Cu(bpy)(H(2)O)(2)(BF(4)),(bpy) (bpy = 4,4'-bipyridine) [Cu-MOF] have been evidenced by combined NMR and EPR spectroscopy. Upon adsorption of probe molecules even at a few mbar, EPR spectra show that they are activated to form complexes at Cu(II) sites, which results in a change of the Cu-MOF's structure as indicated by a high-field shift of the (11)B MAS NMR. After desorption, both EPR and (11)B MAS NMR spectra evidenced that the structure of the Cu-MOF reversibly shifted to the original state. This observation indicates that MOFs can undergo structural changes during processes where adsorption-desorption steps are involved such as gas storage, separation, and catalysis.

  10. Recent Advances in Bacteria Identification by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Using Nanomaterials as Affinity Probes

    Directory of Open Access Journals (Sweden)

    Tai-Chia Chiu

    2014-04-01

    Full Text Available Identifying trace amounts of bacteria rapidly, accurately, selectively, and with high sensitivity is important to ensuring the safety of food and diagnosing infectious bacterial diseases. Microbial diseases constitute the major cause of death in many developing and developed countries of the world. The early detection of pathogenic bacteria is crucial in preventing, treating, and containing the spread of infections, and there is an urgent requirement for sensitive, specific, and accurate diagnostic tests. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS is an extremely selective and sensitive analytical tool that can be used to characterize different species of pathogenic bacteria. Various functionalized or unmodified nanomaterials can be used as affinity probes to capture and concentrate microorganisms. Recent developments in bacterial detection using nanomaterials-assisted MALDI-MS approaches are highlighted in this article. A comprehensive table listing MALDI-MS approaches for identifying pathogenic bacteria, categorized by the nanomaterials used, is provided.

  11. Pigments and proteins in green bacterial chlorosomes studied by matrix-assisted laser desorption ionization mass spectrometry

    DEFF Research Database (Denmark)

    Persson, S; Sönksen, C P; Frigaard, N U;

    2000-01-01

    We have used matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for mass determination of pigments and proteins in chlorosomes, the light-harvesting organelles from the photosynthetic green sulfur bacterium Chlorobium tepidum. By applying a small volume (1...... proportional to peak areas obtained from HPLC analysis of the same sample. The same result was also obtained when whole cells of Chl. tepidum were applied to the target, indicating that MALDI-MS can provide a rapid method for obtaining a semiquantitative determination or finger-print of the bacteriochlorophyll...... homologs in a small amount of green bacterial cells. In addition to information on pigments, the MALDI spectra also contained peaks from chlorosome proteins. Thus we have been able with high precision to confirm the molecular masses of the chlorosome proteins CsmA and CsmE which have been previously...

  12. Analysis and Quantitation of Glycated Hemoglobin by Matrix Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Hattan, Stephen J; Parker, Kenneth C; Vestal, Marvin L; Yang, Jane Y; Herold, David A; Duncan, Mark W

    2016-03-01

    Measurement of glycated hemoglobin is widely used for the diagnosis and monitoring of diabetes mellitus. Matrix assisted laser desorption/ionization (MALDI) time of flight (TOF) mass spectrometry (MS) analysis of patient samples is used to demonstrate a method for quantitation of total glycation on the β-subunit of hemoglobin. The approach is accurate and calibrated with commercially available reference materials. Measurements were linear (R(2) > 0.99) across the clinically relevant range of 4% to 20% glycation with coefficients of variation of ≤ 2.5%. Additional and independent measurements of glycation of the α-subunit of hemoglobin are used to validate β-subunit glycation measurements and distinguish hemoglobin variants. Results obtained by MALDI-TOF MS were compared with those obtained in a clinical laboratory using validated HPLC methodology. MALDI-TOF MS sample preparation was minimal and analysis times were rapid making the method an attractive alternative to methodologies currently in practice.

  13. Detection of Posaconazole by Surface-Assisted Laser Desorption/Ionization Mass Spectrometry with Dispersive Liquid-Liquid Microextraction

    Science.gov (United States)

    Lin, Sheng-Yu; Chen, Pin-Shiuan; Chang, Sarah Y.

    2015-03-01

    A simple, rapid, and sensitive method for the detection of posaconazole using dispersive liquid-liquid microextraction (DLLME) coupled to surface-assisted laser desorption/ionization mass spectrometric detection (SALDI/MS) was developed. After the DLLME, posaconazole was detected using SALDI/MS with colloidal gold and α-cyano-4-hydroxycinnamic acid (CHCA) as the co-matrix. Under optimal extraction and detection conditions, the calibration curve, which ranged from 1.0 to 100.0 nM for posaconazole, was observed to be linear. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 0.3 nM for posaconazole. This novel method was successfully applied to the determination of posaconazole in human urine samples.

  14. Matrix assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) for direct visualization of plant metabolites in situ.

    Science.gov (United States)

    Sturtevant, Drew; Lee, Young-Jin; Chapman, Kent D

    2016-02-01

    Direct visualization of plant tissues by matrix assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) has revealed key insights into the localization of metabolites in situ. Recent efforts have determined the spatial distribution of primary and secondary metabolites in plant tissues and cells. Strategies have been applied in many areas of metabolism including isotope flux analyses, plant interactions, and transcriptional regulation of metabolite accumulation. Technological advances have pushed achievable spatial resolution to subcellular levels and increased instrument sensitivity by several orders of magnitude. It is anticipated that MALDI-MSI and other MSI approaches will bring a new level of understanding to metabolomics as scientists will be encouraged to consider spatial heterogeneity of metabolites in descriptions of metabolic pathway regulation.

  15. Characterization of aromaticity in analogues of titan's atmospheric aerosols with two-step laser desorption ionization mass spectrometry

    CERN Document Server

    Mahjoub, Ahmed; Carrasco, Nathalie; Benilan, Yves; Cernogora, Guy; Szopa, Cyril; Gazeau, Marie-Claire

    2016-01-01

    The role of polycyclic aromatic hydrocarbons (PAH) and Nitrogen containing PAH (PANH) as intermediates of aerosol production in the atmosphere of Titan has been a subject of controversy for a long time. An analysis of the atmospheric emission band observed by the Visible and Infrared Mapping Spectrometer (VIMS) at 3.28 micrometer suggests the presence of neutral polycyclic aromatic species in the upper atmosphere of Titan. These molecules are seen as the counter part of negative and positive aromatics ions suspected by the Plasma Spectrometer onboard the Cassini spacecraft, but the low resolution of the instrument hinders any molecular speciation. In this work we investigate the specific aromatic content of Titan's atmospheric aerosols through laboratory simulations. We report here the selective detection of aromatic compounds in tholins, Titan's aerosol analogues, produced with a capacitively coupled plasma in a N2:CH4 95:5 gas mixture. For this purpose, Two-Step Laser Desorption Ionization Time-of-Flight Ma...

  16. Analysis of chlorophylls and their derivatives by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry.

    Science.gov (United States)

    Suzuki, Toshiyuki; Midonoya, Hitoshi; Shioi, Yuzo

    2009-07-01

    The analysis of chlorophylls and their derivatives by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry is described. Four matrices-sinapinic acid, a-cyano-4-hydroxycinnnamic acid, terthiophene, and 3-aminoquinoline-were examined to determine optimal conditions for analysis of the molecular mass and structure of chlorophyll a as a representative chlorophyll. Among them, terthiophene was the most efficient without releasing metal ions, although it caused fragmentation of the phytol-ester linkage. Terthiophene was useful for the analyses of chlorophyll derivatives as well as porphyrin products such as 8-deethyl-8-vinyl-chlorophyll a, pheophorbide a, pyropheophorbide a, bacteriochlorophyll a esterified phytol, and protoporphyrin IX. The current method is suitable for rapid and accurate determination of the molecular mass and structure of chlorophylls and porphyrins.

  17. Aptamer-conjugated multifunctional nanoflowers as a platform for targeting, capture, and detection in laser desorption ionization mass spectrometry.

    Science.gov (United States)

    Ocsoy, Ismail; Gulbakan, Basri; Shukoor, Mohammed Ibrahim; Xiong, Xiangling; Chen, Tao; Powell, David H; Tan, Weihong

    2013-01-22

    Although many different nanomaterials have been tested as substrates for laser desorption and ionization mass spectrometry (LDI-MS), this emerging field still requires more efficient multifuncional nanomaterials for targeting, enrichment, and detection. Here, we report the use of gold manganese oxide (Au@MnO) hybrid nanoflowers as an efficient matrix for LDI-MS. The nanoflowers were also functionalized with two different aptamers to target cancer cells and capture adenosine triphosphate (ATP). These nanoflowers were successfully used for metabolite extraction from cancer cell lysates. Thus, in one system, our multifunctional nanoflowers can (1) act as an ionization substrate for mass spectrometry, (2) target cancer cells, and (3) detect and analyze metabolites from cancer cells.

  18. Aptamer Conjugated Multifunctional Nanoflowers as a Platform for Targeting, Capture and Detection in Laser Desorption Ionization Mass Spectrometry

    Science.gov (United States)

    Ocsoy, Ismail; Gulbakan, Basri; Shukoor, Mohammed Ibrahim; Xiong, Xiangling; Chen, Tao; Powell, David H.; Tan, Weihong

    2013-01-01

    Although many different nanomaterials have been tested as substrates for laser desorption and ionization mass spectrometry (LDI-MS), this emerging field still requires more efficient multifuncional nanomaterials for targeting, enrichment and detection. Here, we report the use of gold-manganese oxide (Au@MnO) hybrid nanoflowers as an efficient matrix for LDI–MS. The nanoflowers were also functionalized with two different aptamers to target cancer cells and capture adenosine triphosphate (ATP), respectively. These nanoflowers were successfully used for metabolite extraction from cancer cell lysates. Thus, in one system, our multifunctional nanoflowers can 1) act as an ionization substrate for mass spectrometry, 2) target cancer cells, and 3) detect and analyze metabolites from cancer cells. PMID:23211039

  19. On plate graphite supported sample processing for simultaneous lipid and protein identification by matrix assisted laser desorption ionization mass spectrometry.

    Science.gov (United States)

    Calvano, Cosima Damiana; van der Werf, Inez Dorothé; Sabbatini, Luigia; Palmisano, Francesco

    2015-05-01

    The simultaneous identification of lipids and proteins by matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS) after direct on-plate processing of micro-samples supported on colloidal graphite is demonstrated. Taking advantages of large surface area and thermal conductivity, graphite provided an ideal substrate for on-plate proteolysis and lipid extraction. Indeed proteins could be efficiently digested on-plate within 15 min, providing sequence coverages comparable to those obtained by conventional in-solution overnight digestion. Interestingly, detection of hydrophilic phosphorylated peptides could be easily achieved without any further enrichment step. Furthermore, lipids could be simultaneously extracted/identified without any additional treatment/processing step as demonstrated for model complex samples such as milk and egg. The present approach is simple, efficient, of large applicability and offers great promise for protein and lipid identification in very small samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Affinity labeling coupled with matrix assistant laser desorption tandem time of flight mass spectrometry for quantitative proteomies research

    Institute of Scientific and Technical Information of China (English)

    MENG Qingfang; ZHANG Yangjun; CAI Yun; QIAN Xiaohong

    2007-01-01

    A relative quantitative method for differential proteomics by cleavable isotope-coded atTmity tag (cICAT)and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF-MS) was estab-lished. The accuracy and reproducibility of the method were evaluated by bovine serum albumin (BSA) digest as having a relative standard deviation of less than 30% and good reproducibility. The dynamic range was als0 evaluated by analyzing two mixtures of several standard proteins with dif-ferent concentration. The experimental results showed that in the dynamic range of 1:30, the quantitation error of the method was less than 30%. Although the quantitation error becomes very large when used beyond this range, it does not affect the derivation of information on the differential proteins. All the work provides an alternative method for differential proteomics analysis in biological samples from different origins.

  1. Quantitative matrix-assisted laser desorption ionization-time-of-flight mass spectrometry analysis of synthetic polymers and peptides.

    Science.gov (United States)

    Hyzak, Lukas; Moos, Rebecca; von Rath, Friederike; Wulf, Volker; Wirtz, Michaela; Melchior, David; Kling, Hans-Willi; Köhler, Michael; Gäb, Siegmar; Schmitz, Oliver J

    2011-12-15

    Matrix-assisted laser desorption ionization (MALDI) is a very powerful and widely used mass spectrometric technique to ionize high molecular weight compounds. The most commonly used dried droplet (DD) technique can lead to a concentration distribution of the analyte on the target and is therefore often not suitable for reproducible analyses. We developed a new solvent-free deposition technique, called compressed sample (CS), to prevent the distribution of the analytes caused by the crystallization of the compounds. The CS technique presented in this work allows the quantitative analysis of synthetic polymers such as derivatized maltosides with correlation coefficients of 0.999 and peptides up to 3500 Da with correlation coefficients of at least 0.982 without the use of stable-isotope-labeled standards.

  2. Structural characterization of phospholipids by matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Marto, J A; White, F M; Seldomridge, S; Marshall, A G

    1995-11-01

    Matrix-assisted laser desorption/ionization (MALDI) Fourier transform ion cyclotron resonance mass spectrometry provides for structural analysis of the principal biological phospholipids: glycerophosphatidylcholine, -ethanolamine, -serine, and -inositol. Both positive and negative molecular or quasimolecular ions are generated in high abundance. Isolated molecular ions may be collisionally activated in the source side of a dual trap mass analyzer, yielding fragments serving to identify the polar head group (positive ion mode) and fatty acid side chains (negative ion mode). Azimuthal quadrupolar excitation following collisionally activated dissociation refocuses productions close to the solenoid axis; subsequent transfer of product ions to the analyzer ion trap allows for high-resolution mass analysis. Cyro-cooling of the sample probe with liquid nitrogen greatly reduces matrix adduction encountered in the negative ion mode.

  3. Laser Desorption/Ionization Mass Spectrometric Imaging of Endogenous Lipids from Rat Brain Tissue Implanted with Silver Nanoparticles

    Science.gov (United States)

    Muller, Ludovic; Baldwin, Kathrine; Barbacci, Damon C.; Jackson, Shelley N.; Roux, Aurélie; Balaban, Carey D.; Brinson, Bruce E.; McCully, Michael I.; Lewis, Ernest K.; Schultz, J. Albert; Woods, Amina S.

    2017-08-01

    Mass spectrometry imaging (MSI) of tissue implanted with silver nanoparticulate (AgNP) matrix generates reproducible imaging of lipids in rodent models of disease and injury. Gas-phase production and acceleration of size-selected 8 nm AgNP is followed by controlled ion beam rastering and soft landing implantation of 500 eV AgNP into tissue. Focused 337 nm laser desorption produces high quality images for most lipid classes in rat brain tissue (in positive mode: galactoceramides, diacylglycerols, ceramides, phosphatidylcholines, cholesteryl ester, and cholesterol, and in negative ion mode: phosphatidylethanolamides, sulfatides, phosphatidylinositol, and sphingomyelins). Image reproducibility in serial sections of brain tissue is achieved within lipid types having the fatty acid as a subunit. Almost no argentated intact fatty acid ions come from the pure fatty acid standard on tissue.

  4. Identification of Haemophilus influenzae and Haemophilus haemolyticus by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Bruin, J P; Kostrzewa, M; van der Ende, A; Badoux, P; Jansen, R; Boers, S A; Diederen, B M W

    2014-02-01

    Generally accepted laboratory methods that have been used for decades do not reliably distinguish between H. influenzae and H. haemolyticus isolates. H. haemolyticus strains are often incorrectly identified as nontypeable Haemophilus influenzae (NTHi). To distinguish H. influenzae from H. haemolyticus we have created a new database on the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) bio-typer 2 and compared the results with routine determination of Haemophilus (growth requirement for X and V factor), and multilocus sequence typing (MLST). In total we have tested 277 isolates, 244 H. influenzae and 33 H. haemolyticus. Using MLST as the gold standard, the agreement of MALDI-TOF MS was 99.6 %. MALDI-TOF MS allows reliable and rapid discrimination between H. influenzae and H. haemolyticus.

  5. Analysis and Quantitation of Glycated Hemoglobin by Matrix Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

    Science.gov (United States)

    Hattan, Stephen J.; Parker, Kenneth C.; Vestal, Marvin L.; Yang, Jane Y.; Herold, David A.; Duncan, Mark W.

    2016-03-01

    Measurement of glycated hemoglobin is widely used for the diagnosis and monitoring of diabetes mellitus. Matrix assisted laser desorption/ionization (MALDI) time of flight (TOF) mass spectrometry (MS) analysis of patient samples is used to demonstrate a method for quantitation of total glycation on the β-subunit of hemoglobin. The approach is accurate and calibrated with commercially available reference materials. Measurements were linear (R2 > 0.99) across the clinically relevant range of 4% to 20% glycation with coefficients of variation of ≤ 2.5%. Additional and independent measurements of glycation of the α-subunit of hemoglobin are used to validate β-subunit glycation measurements and distinguish hemoglobin variants. Results obtained by MALDI-TOF MS were compared with those obtained in a clinical laboratory using validated HPLC methodology. MALDI-TOF MS sample preparation was minimal and analysis times were rapid making the method an attractive alternative to methodologies currently in practice.

  6. Generation of highly charged peptide and protein ions by atmospheric pressure matrix-assisted infrared laser desorption/ionization ion trap mass spectrometry.

    Science.gov (United States)

    König, Simone; Kollas, Oliver; Dreisewerd, Klaus

    2007-07-15

    We show that highly charged ions can be generated if a pulsed infrared laser and a glycerol matrix are employed for atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry with a quadrupole ion trap. Already for small peptides like bradykinin, doubly protonated ions form the most abundant analyte signal in the mass spectra. The center of the charge-state distribution increases with the size of the analyte. For example, insulin is detected with a most abundant ion signal corresponding to a charge state of four, whereas for cytochrome c, the 10 times protonated ion species produces the most intense signal. Myoglobin is observed with up to 13 charges. The high m/z ratios allow us to use the Paul trap for the detection of MALDI-generated protein ions that are, owing to their high molecular weight, not amenable in their singly protonated charge state. Formation of multiple charges critically depends on the addition of diluted acid to the analyte-matrix solution. Tandem mass spectra generated by collision-induced dissociation of doubly charged peptides are also presented. The findings allow speculations about the involvement of electrospray ionization processes in these MALDI experiments.

  7. Platinum vapor deposition surface-assisted laser desorption/ionization for imaging mass spectrometry of small molecules.

    Science.gov (United States)

    Kawasaki, Hideya; Ozawa, Tomoyuki; Hisatomi, Hirotaka; Arakawa, Ryuichi

    2012-08-30

    Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) allows for the simultaneous detection and imaging of several molecules in a sample. However, when using an organic matrix in the MALDI-IMS of small molecules, inhomogeneous matrix crystallization may yield poorly reproducible peaks in the mass spectra. We describe a solvent-free approach that employs a homogeneously deposited metal nanoparticle layer (or film) for small-molecule detection. Platinum vapor deposition surface-assisted laser desorption/ionization imaging mass spectrometry (Pt vapor deposition SALDI-IMS) of small molecules was performed as a solvent-free and organic-matrix-free method. A commercially available magnetron sputtering device was used for Pt deposition. Vapor deposition of Pt produced a homogenous layer of nanoparticles over the surface of the target imaging sample. The effectiveness of Pt vapor deposition SALDI-IMS was demonstrated for the direct detection of small analytes of inkjet ink on printed paper as well as for various other analytes (saccharides, pigments, and drugs) separated by thin-layer chromatography (TLC), without the need for extraction or concentration processes. The advantage of choosing Pt instead of Au in SALDI-IMS was also shown. A solvent-free approach involving the direct deposition of Pt on samples (SALDI-IMS) is effective for the analysis of inkjet-printed papers and various analytes separated by TLC. This method would be useful in imaging analyses of various insulating materials such as polymers and biological materials. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Detection of drugs in lifted cyanoacrylate-developed latent fingermarks using two laser desorption/ionisation mass spectrometric methods.

    Science.gov (United States)

    Sundar, Latha; Rowell, Frederick

    2014-02-01

    This paper describes a method for lifting cyanoacrylate (CNA)-developed latent fingermarks from a glass surface and the detection of five drugs in lifted marks from fingers that had been in contact with the drugs, using Surface Assisted Laser Desorption Ionisation Time of Flight Mass Spectrometry (SALDI-TOF-MS) or Matrix Assisted Laser Desorption Ionisation TOF-MS (MALDI-TOF-MS). Two drugs of abuse (cocaine and methadone) and three therapeutic drugs (aspirin, paracetamol and caffeine) were used as contact residues. Latent fingermarks spiked with the drugs were subjected to CNA fuming followed by dusting with ARRO SupraNano™ MS black magnetic powder (SALDI-TOF-MS) or 2,5-dihydroxybenzoic acid (DHB) (MALDI-TOF-MS). The dusted mark was then exposed to solvent vapour before lifting with a commercial fingerprint lifting tape following established procedures. The presence of the drugs was then confirmed by direct analysis on the tape without further processing using SALDI- or MALDI-TOF-MS. The black magnetic fingerprint powder provided visual enhancement of the CNA-fingermark while no visual enhancement was observed for marks dusted with DHB powder. Similar [M + H](+) peaks for all the drug analytes were observed for both methods along with some sodium and potassium adducts for SALDI-MS and some major fragment ions but the SALDI signals were generally more intense. Simple exposure to acetone vapour of the CNA-developed marks enabled their effective transfer onto the tape which was crucial for subsequent MS detection of the analytes.

  9. Discrimination between bacterial spore types using time-of-flight mass spectrometry and matrix-free infrared laser desorption and ionization.

    Science.gov (United States)

    Ullom, J N; Frank, M; Gard, E E; Horn, J M; Labov, S E; Langry, K; Magnotta, F; Stanion, K A; Hack, C A; Benner, W H

    2001-05-15

    We demonstrate that molecular ions with mass-to-charge ratios (m/z) ranging from a few hundred to 19 050 can be desorbed from whole bacterial spores using infrared laser desorption and no chemical matrix. We have measured the mass of these ions using time-of-flight mass spectrometry and we observe that different ions are desorbed from spores of Bacillus cereus, Bacillus thuringiensis, Bacillus subtilis, and Bacillus niger. Our results raise the possibility of identifying microorganisms using mass spectrometry without conventional sample preparation techniques such as the addition of a matrix. We have measured the dependence of the ion yield from B. subtilis on desorption wavelength over the range 3.05-3.8 microm, and we observe the best results at 3.05 microm. We have also generated mass spectra from whole spores using 337-nm ultraviolet laser desorption, and we find that these spectra are inferior to spectra generated with infrared desorption. Since aerosol analysis is a natural application for matrix-free desorption, we have measured mass spectra from materials such as ragweed pollen and road dust that are likely to form a background to microbial aerosols. We find that these materials are readily differentiated from bacterial spores.

  10. Laser-induced damage in optical materials

    CERN Document Server

    Ristau, Detlev

    2014-01-01

    Dedicated to users and developers of high-powered systems, Laser-Induced Damage in Optical Materials focuses on the research field of laser-induced damage and explores the significant and steady growth of applications for high-power lasers in the academic, industrial, and military arenas. Written by renowned experts in the field, this book concentrates on the major topics of laser-induced damage in optical materials and most specifically addresses research in laser damage that occurs in the bulk and on the surface or the coating of optical components. It considers key issues in the field of hi

  11. Ultrafast Desorption by Impulsive Vibrational Excitation (DIVE). Applications in laser surgery, mass spectrometry and towards ultimate limits in biodiagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Ling

    2015-07-15

    The prospects for minimally invasive surgery, spatial imaging with mass spectrometry and rapid high throughput biodiagnosis require new means of tissue incision and biomolecule extraction with conserved molecular structure. Towards this aim, a laser ablation process is utilized in this dissertation, which is capable of performing precise tissue incision with minimal collateral damage and extracting intact biological entities with conserved biological functions. The method is based on the recently developed Picosecond Infrared Laser (PIRL) designed to excite selectively the water vibrational modes under the condition of ultrafast Desorption by Impulsive Vibrational Excitation (DIVE). The basic concept is that the selectively excited water molecules act as propellant to ablate whole biological complexes into the plume, faster than any thermal deleterious effect or fragmentation that would mask molecular identities.The PIRL ablation under DIVE condition is applied for the first time to six types of ocular tissues, rendering precise and minimally invasive incisions in a well-controlled and reproducible way. An eminent demonstration is the contact-free and applanation-free corneal trephination with the PIRL. Mass spectrometry and other analytical techniques show that great abundance of proteins with various molecular weights are extracted from the tissue by the PIRL ablation, and that fragmentation or other chemical alternation does not occur to the proteins in the ablation plume. With various microscope imaging and biochemical analysis methods, nano-scale single protein molecules, viruses and cells in the ablation plume are found to be morphologically and functionally identical to their corresponding controls. The PIRL ablation provides a new means to push the frontiers of laser surgery in ophthalmology and can be applied to resolve chemical activities in situ and in vivo. The most important finding is the conserved nature of the extracted biological entities

  12. Femtosecond Laser Desorption of Thin Polymer Films from a Dielectric Surface

    Directory of Open Access Journals (Sweden)

    Mercadier L.

    2013-11-01

    Full Text Available We desorb polymer films from fused silica with a femtosecond laser and characterize the results by atomic force microscopy. Our study as a function of beam geometry and energy reveals two ways of achieving spatially controlled nanodesorption.

  13. Laser desorption-ion mobility spectrometry as a useful tool for imaging of thin layer chromatography surface.

    Science.gov (United States)

    Ilbeigi, Vahideh; Sabo, Martin; Valadbeigi, Younes; Matejcik, Stefan; Tabrizchi, Mahmoud

    2016-08-12

    We present a novel method for coupling thin layer chromatography (TLC) with ion mobility spectrometry (IMS) using laser desorption technique (LD). After separation of the compounds by TLC, the TLC surface was sampled by the LD-IMS without any further manipulation or preparation. The position of the laser was fixed and the TLC plate was moved in desired directions by the motorized micro-positioning stage. The method was successfully applied to analyze the TLC plates containing explosives (tri nitro toluene, 1,3,5-trinitro- 1,3,5-triazacyclohexane, pentaerythritol tetranitrate, 2,4-dinitro toluene and 3,4-dinitro toluene), amino acids (alanine, proline and isoleucine), nicotine and diphenylamine mixtures and detection limits for these compounds were determined. Combination of TLC with LD-IMS technique offers additional separation dimension, allowing separation of overlapping TLC analytes. The time for TLC sampling by LD-IMS was less than 80s. The scan rate for LD is adjustable so that fast and effective analysis of the mixtures is possible with the proposed method. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Direct analysis of textile fabrics and dyes using infrared matrix-assisted laser desorption electrospray ionization mass spectrometry.

    Science.gov (United States)

    Cochran, Kristin H; Barry, Jeremy A; Muddiman, David C; Hinks, David

    2013-01-15

    The forensic analysis of textile fibers uses a variety of techniques from microscopy to spectroscopy. One such technique that is often used to identify the dye(s) within the fiber is mass spectrometry (MS). In the traditional MS method, the dye must be extracted from the fabric and the dye components are separated by chromatography prior to mass spectrometric analysis. Direct analysis of the dye from the fabric allows the omission of the lengthy sample preparation involved in extraction, thereby significantly reducing the overall analysis time. Herein, a direct analysis of dyed textile fabric was performed using the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source for MS. In MALDESI, an IR laser with wavelength tuned to 2.94 μm is used to desorb the dye from the fabric sample with the aid of water as the matrix. The desorbed dye molecules are then postionized by electrospray ionization (ESI). A variety of dye classes were analyzed from various fabrics with little to no sample preparation allowing for the identification of the dye mass and in some cases the fiber polymer. Those dyes that were not detected using MALDESI were also not observed by direct infusion ESI of the dye standard.

  15. Coupling Laser Diode Thermal Desorption with Acoustic Sample Deposition to Improve Throughput of Mass Spectrometry-Based Screening.

    Science.gov (United States)

    Haarhoff, Zuzana; Wagner, Andrew; Picard, Pierre; Drexler, Dieter M; Zvyaga, Tatyana; Shou, Wilson

    2016-02-01

    The move toward label-free screening in drug discovery has increased the demand for mass spectrometry (MS)-based analysis. Here we investigated the approach of coupling acoustic sample deposition (ASD) with laser diode thermal desorption (LDTD)-tandem mass spectrometry (MS/MS). We assessed its use in a cytochrome P450 (CYP) inhibition assay, where a decrease in metabolite formation signifies CYP inhibition. Metabolite levels for 3 CYP isoforms were measured as CYP3A4-1'-OH-midazolam, CYP2D6-dextrorphan, and CYP2C9-4'-OH-diclofenac. After incubation, samples (100 nL) were acoustically deposited onto a stainless steel 384-LazWell plate, then desorbed by an infrared laser directly from the plate surface into the gas phase, ionized by atmospheric pressure chemical ionization (APCI), and analyzed by MS/MS. Using this method, we achieved a sample analysis speed of 2.14 s/well, with bioanalytical performance comparable to the current online solid-phase extraction (SPE)-based MS method. An even faster readout speed was achieved when postreaction sample multiplexing was applied, where three reaction samples, one for each CYP, were transferred into the same well of the LazWell plate. In summary, LDTD coupled with acoustic sample deposition and multiplexing significantly decreased analysis time to 0.7 s/sample, making this MS-based approach feasible to support high-throughput screening (HTS) assays.

  16. Low energy ion induced desorption on technical surfaces at room temperature

    CERN Document Server

    Hulla, Georg

    2009-01-01

    The ion-induced pressure instability is a hard limitation for the maximum intensity, and hence the ultimate luminosity achievable in a proton accelerator. This instability is due to the interaction of high intensity proton beams with the residual gas generating positive ions. These ions, accelerated by the beam space charge, impact on the vaccuum chamber wall and lead to the desorption of gaseous species like $H_{2}, CH_{4}, C_{2}H_{4}, C_{2}H_{6}, CO$ and $CO_{2}$. These gases can in turn be ionized by the circulating beam, and initiate a pressure run-away process causing the loss of the stored beam. This phenomenon was first registered right at the beginning of operation of the Intersecting Storage Rings (ISR) at CERN in 1970. Later on, a long term evolution of the pressure was recorded for a stable stored beam current where a change of the residual gas composition was measured. In order to adapt the pumping speed and the surface treatments to the desired circulating beam currents, mathematical tools (e.g. ...

  17. Review of Heavy-ion Induced Desorption Studies for Particle Accelerators

    CERN Document Server

    Mahner, E

    2008-01-01

    During high-intensity heavy-ion operation of several particle accelerators worldwide, large dynamic pressure rises of orders of magnitude were caused by lost beam ions that impacted under grazing angle onto the vacuum chamber walls. This ion-induced desorption, observed, for example, at CERN, GSI, and BNL, can seriously limit the ion intensity, luminosity, and beam lifetime of the accelerator. For the heavyion program at CERN's Large Hadron Collider collisions between beams of fully stripped lead (208Pb82+) ions with a beam energy of 2.76 TeV/u and a nominal luminosity of 10**27 cm**-2 s**-1 are foreseen. The GSI future project FAIR (Facility for Antiproton and Ion Research) aims at a beam intensity of 10**12 uranium (238U28+) ions per second to be extracted from the synchrotron SIS18. Over the past years an experimental effort has been made to study the observed dynamic vacuum degradations, which are important to understand and overcome for present and future particle accelerators. The paper reviews the resu...

  18. Light-induced atom desorption from glass surfaces characterized by X-ray photoelectron spectroscopy

    Science.gov (United States)

    Kumagai, Ryo; Hatakeyama, Atsushi

    2016-07-01

    We analyzed the surfaces of vitreous silica (quartz) and borosilicate glass (Pyrex) substrates exposed to rubidium (Rb) vapor by X-ray photoelectron spectroscopy (XPS) to understand the surface conditions of alkali metal vapor cells. XPS spectra indicated that Rb atoms adopted different bonding states in quartz and Pyrex. Furthermore, Rb atoms in quartz remained in the near-surface region, while they diffused into the bulk in Pyrex. For these characterized surfaces, we measured light-induced atom desorption (LIAD) of Rb atoms. Clear differences in time evolution, photon energy dependence, and substrate temperature dependence were found; the decay of LIAD by continuous ultraviolet irradiation for quartz was faster than that for Pyrex, a monotonic increase in LIAD with increasing photon energy from 1.8 to 4.3 eV was more prominent for quartz, and LIAD from quartz was more efficient at higher temperatures in the range from 300 to 580 K, while that from Pyrex was almost independent of temperature.

  19. Modeling of laser induced periodic surface structures

    NARCIS (Netherlands)

    Skolski, J.Z.P.; Römer, G.R.B.E.; Huis in 't Veld, A.J.; Mitko, V.S.; Obona, J.V.; Ocelik, V.; Hosson, J.T.M. de

    2010-01-01

    In surfaces irradiated by short laser pulses, Laser Induced Periodic Surface Structures (LIPSS) have been observed on all kind of materials for over forty years. These LIPSS, also referred to as ripples, consist of wavy surfaces with periodicity equal or smaller than the wavelength of the laser radi

  20. Heavy-ion induced desorption yields of cryogenic surfaces bombarded with 4.2  MeV/u lead ions

    Directory of Open Access Journals (Sweden)

    E. Mahner

    2011-05-01

    Full Text Available The ion-induced desorption experiment, installed in the CERN Heavy-Ion Accelerator LINAC 3, has been used to study the dynamic outgassing of cryogenic surfaces. Two different targets, bare and gold-coated copper, were bombarded under perpendicular impact with 4.2  MeV/u Pb^{54+} ions. Partial pressure rises of H_{2}, CH_{4}, CO, and CO_{2} and effective desorption yields were measured at 300, 77, and 6.3 K using single shot and continuous ion bombardment techniques. We find that the heavy-ion-induced desorption yield is temperature dependent and investigate the influence of CO gas cryosorbed at 6.3 K. The gain in desorption yield reduction at cryogenic temperature vanishes after several monolayers of CO are cryosorbed on both targets. In this paper we describe the new cryogenic target assembly, the temperature-dependent pressure rise, desorption yield, and gas adsorption measurements.

  1. Tailored nanopost arrays (NAPA) for laser desorption ionization in mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vertes, Akos; Walker, Bennett N.; Stolee, Jessica A.; Retterer, Scott T.

    2016-11-08

    The production and use of semiconducting nanopost arrays made by nanofabrication is described herein. These nanopost arrays (NAPA) provide improved laser ionization yields and controllable fragmentation with switching or modulation capabilities for mass spectrometric detection and identification of samples deposited on them.

  2. Tailored nanopost arrays (NAPA) for laser desorption ionization in mass spectrometry

    Science.gov (United States)

    Vertes, Akos; Walker, Bennett N.; Stolee, Jessica A.; Retterer, Scott T.

    2016-11-08

    The production and use of semiconducting nanopost arrays made by nanofabrication is described herein. These nanopost arrays (NAPA) provide improved laser ionization yields and controllable fragmentation with switching or modulation capabilities for mass spectrometric detection and identification of samples deposited on them.

  3. Two-Step Resonance-Enhanced Desorption Laser Mass Spectrometry for In Situ Analysis of Organic-Rich Environments

    Science.gov (United States)

    Getty, S. A.; Grubisic, A.; Uckert, K.; Li, X.; Cornish, T.; Cook, J. E.; Brinckerhoff, W. B.

    2016-01-01

    A wide diversity of planetary surfaces in the solar system represent high priority targets for in situ compositional and contextual analysis as part of future missions. The planned mission portfolio will inform our knowledge of the chemistry at play on Mars, icy moons, comets, and primitive asteroids, which can lead to advances in our understanding of the interplay between inorganic and organic building blocks that led to the evolution of habitable environments on Earth and beyond. In many of these environments, the presence of water or aqueously altered mineralogy is an important indicator of habitable environments that are present or may have been present in the past. As a result, the search for complex organic chemistry that may imply the presence of a feedstock, if not an inventory of biosignatures, is naturally aligned with targeted analyses of water-rich surface materials. Here we describe the two-step laser mass spectrometry (L2MS) analytical technique that has seen broad application in the study of organics in meteoritic samples, now demonstrated to be compatible with an in situ investigation with technique improvements to target high priority planetary environments as part of a future scientific payload. An ultraviolet (UV) pulsed laser is used in previous and current embodiments of laser desorption/ionization mass spectrometry (LDMS) to produce ionized species traceable to the mineral and organic composition of a planetary surface sample. L2MS, an advanced technique in laser mass spectrometry, is selective to the aromatic organic fraction of a complex sample, which can provide additional sensitivity and confidence in the detection of specific compound structures. Use of a compact two-step laser mass spectrometer prototype has been previously reported to provide specificity to key aromatic species, such as PAHs, nucleobases, and certain amino acids. Recent improvements in this technique have focused on the interaction between the mineral matrix and the

  4. Surgical Treatment of Laser Induced Eye Injuries

    Science.gov (United States)

    1990-12-05

    AD-A234 849 CONTRACT NO.: DAMD17-89-C-9026 TITLE: SURGICAL TREATMENT OF LASER INDUCED EYE INJURIES AUTHORS: Leonard M. Hjelmeland, Maurice B. Landers...62787A 62787A878 BA JDA318205 11. TITLE (Include Secirity Classification) (U) Surgical Treatment of Laser Induced Eye Injuries 12. PERSONAL AUTHOR(S...TERMS (Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP RA 3; Lasers; Eye injury ; Surgery 09 03 06 04 19. ABSTRACT

  5. Laser-Induced Energy Transfer in Solids

    NARCIS (Netherlands)

    Morsink, J.B.W.; Rullmann, Johan; Wiersma, Douwe

    1981-01-01

    Laser-induced energy transfer was observed and studied in the system pentacene doped into naphthalene. The transfer spectrum shows a remarkable correspondence with the host density of states function. The rate for laser-induced energy transfer is given and it is concluded that most likely, intermole

  6. Pioneers of Study on Desorption Induced by Electronic Transitions; Achievements by Dr. Yoshioki Ishikawa and Dr. Yoshio Ohta

    Science.gov (United States)

    Mase, Kazuhiko; Nambu, Akira

    Dr. Yoshioki Ishikawa is a pioneer who carried out systematic electron stimulated desorption (ESD) investigations for hydrogen adsorbed on a clean platinum plate (H2/Pt) under ultrahigh vacuum (UHV) conditions in 1942. (His name is spelled as Yosioki Isikawa in the original papers.) Although his papers are referred in several papers on desorption induced by electronic transitions (DIET), these seem to be not as well-known as famous ones by Menzel, Gomer, and Redhead in 1964. We describe his pioneering work in this article. He developed an UHV apparatus made of glass with a Pt plate and an oxide cathode pumped by a small mercury pump via a liquid air trap. Clear ESD signals were observed for H2/Pt at excitation energies of 8, 12, 14, 33-46, and 46-51 eV. He assigned the desorbate to atomic hydrogen (H), because it was pumped by a glass wall baked above 350°C. Based on these results and the potential curves of H2 in the gas phase, he proposed a model for the ESD of H from H2/Pt that is, the first step is an electronic transition of adsorbed H2, and the second is the desorption of H along the repulsive potential surface of the excited state. This was the first introduction of the notion of DIET. He also carried out an ESD study of H2O/Pt in 1943. We also introduce achievements by Dr. Yoshio Ohta, who was another pioneer in the field of DIET. He measured electron-stimulated ion desorption from an oxidized Ni plate. He found that the threshold excitation energy for ion desorption is 22 eV, and that the kinetic energy of the desorbed ion is 1˜2 eV. To explain these results, he also proposed the concept of DIET.

  7. Determination of metformin in mouse, rat, dog and human plasma samples by laser diode thermal desorption/atmospheric pressure chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Swales, John G; Gallagher, Richard; Peter, Raimund M

    2010-11-02

    A simple, rapid and robust high-throughput assay for the quantitative analysis of metformin in plasma from different species using laser diode thermal desorption interfaced with atmospheric chemical pressure ionization tandem mass spectrometry (LDTD-APCI-MSMS) was developed for use in a pharmaceutical discovery environment. In order to minimize sample preparation a generic protein precipitation method was used to extract metformin from the plasma. Laser diode thermal desorption is a relatively new sample introduction method, the optimization of the instrumental parameters are presented. The method was successfully applied to spiked mouse, rat, dog and human plasma samples and was subsequently used to determine the oral pharmacokinetics of metformin after dosing to male rats in order to support drug discovery projects. The deviations for intra-assay accuracy and precision across the four species were less than 30% at all calibration and quality control levels.

  8. Simplified sample preparation method for protein identification by matrix-assisted laser desorption/ionization mass spectrometry: in-gel digestion on the probe surface

    DEFF Research Database (Denmark)

    Stensballe, A; Jensen, Ole Nørregaard

    2001-01-01

    Identification and detailed characterization of complex mixtures of proteins separated by polyacrylamide gel electrophoresis (PAGE) require optimized and robust methods for interfacing electrophoretic techniques to mass spectrometry. Peptide mapping by matrix-assisted laser desorption/ionization-......Identification and detailed characterization of complex mixtures of proteins separated by polyacrylamide gel electrophoresis (PAGE) require optimized and robust methods for interfacing electrophoretic techniques to mass spectrometry. Peptide mapping by matrix-assisted laser desorption...... for protein identification similar to that obtained by the traditional protocols for in-gel digestion and MALDI peptide mass mapping of human proteins, i.e. approximately 60%. The overall performance of the novel on-probe digestion method is comparable with that of the standard in-gel sample preparation...

  9. Determination of Macrolide Antibiotics Using Dispersive Liquid-Liquid Microextraction Followed by Surface-Assisted Laser Desorption/Ionization Mass Spectrometry

    Science.gov (United States)

    Chen, Kuan-Yu; Yang, Thomas C.; Chang, Sarah Y.

    2012-06-01

    A novel method for the determination of macrolide antibiotics using dispersive liquid-liquid microextraction coupled to surface-assisted laser desorption/ionization mass spectrometric detection was developed. Acetone and dichloromethane were used as the disperser solvent and extraction solvent, respectively. A mixture of extraction solvent and disperser solvent were rapidly injected into a 1.0 mL aqueous sample to form a cloudy solution. After the extraction, macrolide antibiotics were detected using surface-assisted laser desorption/ionization mass spectrometry (SALDI/MS) with colloidal silver as the matrix. Under optimum conditions, the limits of detection (LODs) at a signal-to-noise ratio of 3 were 2, 3, 3, and 2 nM for erythromycin (ERY), spiramycin (SPI), tilmicosin (TILM), and tylosin (TYL), respectively. This developed method was successfully applied to the determination of macrolide antibiotics in human urine samples.

  10. Verification of a characterization method of the laser-induced selective activation based on industrial lasers

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard; Tang, Peter T.

    2013-01-01

    In this article, laser-induced selective activation (LISA) for subsequent autocatalytic copper plating is performed by several types of industrial scale lasers, including a Nd:YAG laser, a UV laser, a fiber laser, a green laser, and a short pulsed laser. Based on analysis of all the laser-machine...

  11. Characterization of some synthetic Ru and Ir complexes by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Lou, X.; Buijtenen, J. van; Bastiaansen, J.J.A.M.; Waal, B.F.M. de; Langeveld, B.M.W.; Dongen, J.L.J. van

    2005-01-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was applied to the analysis of Ru(OCOCF 3)2(CO)(PPh3)2, Ru(OCOC 3F7)2(CO)(PPh3)2, Ir(tBuppy)3 and Ir(ppy)2(acac) complexes. A troublesome problem in the MALDI-TOFMS characterization of these metal complexes is

  12. Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry for species identification of nonfermenting Gram-negative bacilli.

    Science.gov (United States)

    Almuzara, Marisa; Barberis, Claudia; Traglia, Germán; Famiglietti, Angela; Ramirez, Maria Soledad; Vay, Carlos

    2015-05-01

    Matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) to identify 396 Nonfermenting Gram-Negative Bacilli clinical isolates was evaluated in comparison with conventional phenotypic tests and/or molecular methods. MALDI-TOF MS identified to species level 256 isolates and to genus or complex level 112 isolates. It identified 29 genera including uncommon species. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Differentiation of the Dimorphic Fungal Species Paracoccidioides brasiliensis and Paracoccidioides lutzii

    Science.gov (United States)

    Del Negro, Gilda M. B.; Grenfell, Rafaella C.; Vidal, Monica S. M.; Thomaz, Danilo Y.; de Figueiredo, Dulce S. Y.; Bagagli, Eduardo; Juliano, Luiz; Benard, Gil

    2015-01-01

    Isolates of Paracoccidioides brasiliensis and Paracoccidioides lutzii, previously characterized by molecular techniques, were identified for the first time by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS). All isolates were correctly identified, with log score values of >2.0. Thus, MALDI-TOF MS is a new tool for differentiating species of the genus Paracoccidioides. PMID:25631803

  14. Does the Capsule Interfere with Performance of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of Cryptococcus neoformans and Cryptococcus gattii?

    Science.gov (United States)

    Grenfell, Rafaella C.; Vidal, Monica S. M.; Giudice, Mauro C.; Del Negro, Gilda M. B.; Juliano, Luiz; Benard, Gil; de Almeida Júnior, João N.

    2015-01-01

    We described the impact of the capsule size for Cryptococcus neoformans and Cryptococcus gattii identification at the species level by Bruker matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS). After experimental capsule size modulation, we observed that reducing the capsule size resulted in improved identification by Bruker MALDI-TOF MS across all of the reference strains analyzed. PMID:26659203

  15. Rapid on-site detection of explosives on surfaces by ambient pressure laser desorption and direct inlet single photon ionization or chemical ionization mass spectrometry.

    Science.gov (United States)

    Ehlert, S; Hölzer, J; Rittgen, J; Pütz, M; Schulte-Ladbeck, R; Zimmermann, R

    2013-09-01

    Considering current security issues, powerful tools for detection of security-relevant substances such as traces of explosives and drugs/drug precursors related to clandestine laboratories are required. Especially in the field of detection of explosives and improvised explosive devices, several relevant compounds exhibit a very low vapor pressure. Ambient pressure laser desorption is proposed to make these substances available in the gas phase for the detection by adapted mass spectrometers or in the future with ion-mobility spectrometry as well. In contrast to the state-of-the-art thermal desorption approach, by which the sample surface is probed for explosive traces by a wipe pad being transferred to a thermal desorber unit, by the ambient pressure laser desorption approach presented here, the sample is directly shockwave ablated from the surface. The laser-dispersed molecules are sampled by a heated sniffing capillary located in the vicinity of the ablation spot into the mass analyzer. This approach has the advantage that the target molecules are dispersed more gently than in a thermal desorber unit where the analyte molecules may be decomposed by the thermal intake. In the technical realization, the sampling capillary as well as the laser desorption optics are integrated in the tip of an endoscopic probe or a handheld sampling module. Laboratory as well as field test scenarios were performed, partially in cooperation with the Federal Criminal Police Office (Bundeskriminalamt, BKA, Wiesbaden, Germany), in order to demonstrate the applicability for various explosives, drugs, and drug precursors. In this work, we concentrate on the detection of explosives. A wide range of samples and matrices have been investigated successfully.

  16. Characterization of some synthetic Ru and Ir complexes by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Lou, X.; Buijtenen, J. van; Bastiaansen, J.J.A.M.; Waal, B.F.M. de; Langeveld, B.M.W.; Dongen, J.L.J. van

    2005-01-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was applied to the analysis of Ru(OCOCF 3)2(CO)(PPh3)2, Ru(OCOC 3F7)2(CO)(PPh3)2, Ir(tBuppy)3 and Ir(ppy)2(acac) complexes. A troublesome problem in the MALDI-TOFMS characterization of these metal complexes is

  17. Identification of non-diphtheriae corynebacterium by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Alatoom, Adnan A; Cazanave, Charles J; Cunningham, Scott A; Ihde, Sherry M; Patel, Robin

    2012-01-01

    We evaluated the Bruker Biotyper matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for identification of 92 clinical isolates of Corynebacterium species in comparison to identification using rpoB or 16S rRNA gene sequencing. Eighty isolates (87%) yielded a score of ≥1.700, and all of these were correctly identified to the species level with the exception of Corynebacterium aurimucosum being misidentified as the closely related Corynebacterium minutissimum.

  18. Assessment of Reproducibility of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Bacterial and Yeast Identification

    OpenAIRE

    Westblade, Lars F.; Garner, Omai B.; MacDonald,Karen; Bradford, Constance; Pincus, David H.; Mochon, A. Brian; Jennemann, Rebecca; Manji, Ryhana; Bythrow, Maureen; Lewinski, Michael A.; Burnham, Carey-Ann D.; Ginocchio, Christine C.

    2015-01-01

    Matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry (MS) has revolutionized the identification of clinical bacterial and yeast isolates. However, data describing the reproducibility of MALDI-TOF MS for microbial identification are scarce. In this study, we show that MALDI-TOF MS-based microbial identification is highly reproducible and can tolerate numerous variables, including differences in testing environments, instruments, operators, reagent lots, and ...

  19. Differentiation of Raoultella ornithinolytica/planticola and Klebsiella oxytoca clinical isolates by matrix-assisted laser desorption/ionization-time of flight mass spectrometry.

    Science.gov (United States)

    de Jong, Eefje; de Jong, Arjan S; Smidts-van den Berg, Nathalie; Rentenaar, Rob J

    2013-04-01

    Ninety-nine clinical isolates previously identified as Klebsiella oxytoca were evaluated using matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). Eight isolates were identified as Raoultella spp., being 5 Raoultella spp. and 3 K. oxytoca, by 16S rRNA sequencing. These isolates were correctly identified by applying the 10% differential rule for the MALDI-TOF MS score values. This approach might be useful to discriminate Raoultella species from K. oxytoca.

  20. Influence of Culture Media on Detection of Carbapenem Hydrolysis by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Ramos, Ana Carolina; Carvalhaes, Cecília Godoy; Cordeiro-Moura, Jhonatha Rodrigo; Rockstroh, Anna Carolina; Machado, Antonia Maria Oliveira; Gales, Ana Cristina

    2016-07-01

    In this study, we evaluated the influence of distinct bacterial growth media on detection of carbapenemase hydrolysis by matrix-assisted laser desorption ionization-time of flight mass spectrometry. False-negative results were observed for OXA-25-, OXA-26-, and OXA-72-producing Acinetobacter baumannii isolates grown on MacConkey agar medium. The other culture media showed 100% sensitivity and 100% specificity for detecting carbapenemase.

  1. Proteomic-based prognosis of brain tumor patients using direct-tissue matrix-assisted laser desorption ionization mass spectrometry.

    Science.gov (United States)

    Schwartz, Sarah A; Weil, Robert J; Thompson, Reid C; Shyr, Yu; Moore, Jason H; Toms, Steven A; Johnson, Mahlon D; Caprioli, Richard M

    2005-09-01

    Clinical diagnosis and treatment decisions for a subset of primary human brain tumors, gliomas, are based almost exclusively on tissue histology. Approaches for glioma diagnosis can be highly subjective due to the heterogeneity and infiltrative nature of these tumors and depend on the skill of the neuropathologist. There is therefore a critical need to develop more precise, non-subjective, and systematic methods to classify human gliomas. To this end, mass spectrometric analysis has been applied to these tumors to determine glioma-specific protein patterns. Protein profiles have been obtained from human gliomas of various grades through direct analysis of tissue samples using matrix-assisted laser desorption ionization mass spectrometry (MS). Statistical algorithms applied to the MS profiles from tissue sections identified protein patterns that correlated with tumor histology and patient survival. Using a data set of 108 glioma patients, two patient populations, a short-term and a long-term survival group, were identified based on the tissue protein profiles. In addition, a subset of 57 patients diagnosed with high-grade, grade IV, malignant gliomas were analyzed and a novel classification scheme that segregated short-term and long-term survival patients based on the proteomic profiles was developed. The protein patterns described served as an independent indicator of patient survival. These results show that this new molecular approach to monitoring gliomas can provide clinically relevant information on tumor malignancy and is suitable for high-throughput clinical screening.

  2. Differentiation of blue ballpoint pen inks by laser desorption ionization mass spectrometry and high-performance thin-layer chromatography.

    Science.gov (United States)

    Weyermann, Céline; Marquis, Raymond; Mazzella, Williams; Spengler, Bernhard

    2007-01-01

    The differentiation of inks on a questioned document can highlight a fraudulent insertion and is usually carried out by optical comparison and thin-layer chromatography (TLC). Laser desorption ionization mass spectrometry (LDI-MS) may also be used for the analysis of dyes from ink. This analytical technique was compared with a standard method of high-performance TLC (HPTLC) according to their capacity to differentiate blue ballpoint inks. Ink entries on paper from 31 blue ballpoint pens have been analyzed and their dye ink formulations compared. The pens were classified into 26 classes by LDI-MS against 18 for HPTLC. LDI-MS proved to be a more powerful method for differentiating ink formulations because it provides information about dye structures (molecular weights) and relative quantification of dye classes (peak areas). Sample preparation was minimal and analysis time was short in contrast to the more complex extraction, application, and development steps of the HPTLC method. However, only basic dyes and pigments were identified using positive mode LDI-MS, while HPTLC did yield additional information about acid dyes.

  3. Direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry improves appropriateness of antibiotic treatment of bacteremia.

    Science.gov (United States)

    Vlek, Anne L M; Bonten, Marc J M; Boel, C H Edwin

    2012-01-01

    Matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows the identification of microorganisms directly from positive blood culture broths. Use of the MALDI-TOF MS for rapid identification of microorganisms from blood culture broths can reduce the turnaround time to identification and may lead to earlier appropriate treatment of bacteremia. During February and April 2010, direct MALDI-TOF MS was routinely performed on all positive blood cultures. During December 2009 and March 2010 no direct MALDI-TOF MS was used. Information on antibiotic therapy was collected from the hospital and intensive care units' information systems from all positive blood cultures during the study period. In total, 253 episodes of bacteremia were included of which 89 during the intervention period and 164 during the control period. Direct performance of MALDI-TOF MS on positive blood culture broths reduced the time till species identification by 28.8-h and was associated with an 11.3% increase in the proportion of patients receiving appropriate antibiotic treatment 24 hours after blood culture positivity (64.0% in the control period versus 75.3% in the intervention period (p0.01)). Routine implementation of this technique increased the proportion of patients on adequate antimicrobial treatment within 24 hours.

  4. Direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry improves appropriateness of antibiotic treatment of bacteremia.

    Directory of Open Access Journals (Sweden)

    Anne L M Vlek

    Full Text Available Matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS allows the identification of microorganisms directly from positive blood culture broths. Use of the MALDI-TOF MS for rapid identification of microorganisms from blood culture broths can reduce the turnaround time to identification and may lead to earlier appropriate treatment of bacteremia. During February and April 2010, direct MALDI-TOF MS was routinely performed on all positive blood cultures. During December 2009 and March 2010 no direct MALDI-TOF MS was used. Information on antibiotic therapy was collected from the hospital and intensive care units' information systems from all positive blood cultures during the study period. In total, 253 episodes of bacteremia were included of which 89 during the intervention period and 164 during the control period. Direct performance of MALDI-TOF MS on positive blood culture broths reduced the time till species identification by 28.8-h and was associated with an 11.3% increase in the proportion of patients receiving appropriate antibiotic treatment 24 hours after blood culture positivity (64.0% in the control period versus 75.3% in the intervention period (p0.01. Routine implementation of this technique increased the proportion of patients on adequate antimicrobial treatment within 24 hours.

  5. Total microcystins analysis in water using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Roy-Lachapelle, Audrey; Fayad, Paul B; Sinotte, Marc; Deblois, Christian; Sauvé, Sébastien

    2014-04-11

    A new approach for the analysis of the cyanobacterial microcystins (MCs) in environmental water matrices has been developed. It offers a cost efficient alternative method for the fast quantification of total MCs using mass spectrometry. This approach permits the quantification of total MCs concentrations without requiring any derivatization or the use of a suite of MCs standards. The oxidation product 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) was formed through a Lemieux oxidation and represented the total concentration of free and bound MCs in water samples. MMPB was analyzed using laser diode thermal desorption-atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). LDTD is a robust and reliable sample introduction method with ultra-fast analysis time (0.999). Limits of detection and quantification were 0.2 and 0.9 μg L(-1), respectively. These values are comparable with the WHO (World Health Organization) guideline of 1 μg L(-1) for total microcystin-LR congener in drinking water. Accuracy and interday/intraday variation coefficients were below 15%. Matrix effect was determined with a recovery of 91%, showing no significant signal suppression. This work demonstrates the use of the LDTD-APCI-MS/MS interface for the screening, detection and quantification of total MCs in complex environmental matrices.

  6. Novel ionic liquid matrices for qualitative and quantitative detection of carbohydrates by matrix assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Zhao, Xiaoyong; Shen, Shanshan; Wu, Datong; Cai, Pengfei; Pan, Yuanjiang

    2017-09-08

    Analysis of carbohydrates based on matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is still challenging and researchers have been devoting themselves to efficient matrices discovery. In the present study, the design, synthesis, qualitative and quantitative performance of non-derivative ionic liquid matrices (ILMs) were reported. DHB/N-methylaniline (N-MA) and DHB/N-ethylaniline (N-EA), performing best for carbohydrate detection, have been screened out. The limit of detection for oligosaccharide provided by DHB/N-MA and DHB/N-EA were as low as 10 fmol. DHB/N-MA and DHB/N-EA showed significantly higher ion generation efficiency than DHB. The comparison of capacity to probe polysaccharide between these two ILMs and DHB also revealed their powerful potential. Their outstanding performance were probably due to lower proton affinities and stronger UV absorption at λ = 355 nm. What is more, taking DHB/N-MA as an example, quantitative analysis of fructo-oligosaccharide mixtures extracted and identified from rice noodles has been accomplished sensitively using an internal standard method. Overall, DHB/N-MA and DHB/N-EA exhibited excellent performance and might be significant sources as the carbohydrate matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry for the identification of Neisseria gonorrhoeae.

    Science.gov (United States)

    Buchanan, R; Ball, D; Dolphin, H; Dave, J

    2016-09-01

    Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS) was compared with the API NH biochemical method for the identification of Neisseria gonorrhoeae in routine clinical samples. A retrospective review of laboratory records for 1090 isolates for which both biochemical and MALDI-TOF MS identifications were available was performed. Cases of discrepant results were examined in detail for evidence supportive of a particular organism identification. Of 1090 isolates, 1082 were identified as N. gonorrhoeae by API NH. MALDI-TOF MS successfully identified 984 (91%) of these after one analysis, rising to 1081 (99.9%) after two analyses, with a positive predictive value of 99.3%. For those isolates requiring a repeat analysis, failure to generate an identifiable proteomic signature was the reason in 76% of cases, with alternative initial identifications accounting for the remaining 24%. MALDI-TOF MS identified eight isolates as N. gonorrhoeae that were not identified as such by API NH-examination of these discrepant results suggested that the MALDI-TOF MS identification may be the more reliable. MALDI-TOF MS is at least as accurate and reliable a method of identifying N. gonorrhoeae as API NH. We propose that MALDI-TOF MS could potentially be used as a single method for N. gonorrhoeae identification in routine cases by laboratories with access to this technology.

  8. Matrix-assisted laser desorption/ionization mass spectrometry method for selectively producing either singly or multiply charged molecular ions.

    Science.gov (United States)

    Trimpin, Sarah; Inutan, Ellen D; Herath, Thushani N; McEwen, Charles N

    2010-01-01

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is noted for its ability to produce primarily singly charged ions. This is an attribute when using direct ionization for complex mixtures such as protein digests or synthetic polymers. However, the ability to produce multiply charged ions, as with electrospray ionization (ESI), has advantages such as extending the mass range on mass spectrometers with limited mass-to-charge (m/z) range and enhancing fragmentation for structural characterization. We designed and fabricated a novel field free transmission geometry atmopsheric pressure (AP) MALDI source mounted to a high-mass resolution Orbitrap Exactive mass spectrometer. We report the ability to produce at will either singly charged ions or highly charged ions using a MALDI process by simply changing the matrix or the matrix preparation conditions. Mass spectra with multiply charged ions very similar to those obtained with ESI of proteins such as cytochrome c and ubiquitin are obtained with low femtomole amounts applied to the MALDI target plate and for peptides such as angiotensin I and II with application of attomole amounts. Single scan acquisitions produce sufficient ion current even from proteins.

  9. Determination of paclitaxel distribution in solid tumors by nano-particle assisted laser desorption ionization mass spectrometry imaging.

    Directory of Open Access Journals (Sweden)

    Lavinia Morosi

    Full Text Available A sensitive, simple and reproducible protocol for nanoparticle-assisted laser desorption/ionization mass spectrometry imaging technique is described. The use of commercially available TiO2 nanoparticles abolishes heterogeneous crystallization, matrix background interferences and enhances signal detection, especially in the low mass range. Molecular image normalization was based on internal standard deposition on tissues, allowing direct comparison of drug penetration and distribution between different organs and tissues. The method was applied to analyze the distribution of the anticancer drug paclitaxel, inside normal and neoplastic mouse tissue sections. Spatial resolution was good, with a linear response between different in vivo treatments and molecular imaging intensity using therapeutic drug doses. This technique distinguishes the different intensity of paclitaxel distribution in control organs of mice, such as liver and kidney, in relation to the dose. Animals treated with 30 mg/kg of paclitaxel had half of the concentration of those treated with 60 mg/kg. We investigated the spatial distribution of paclitaxel in human melanoma mouse xenografts, following different dosage schedules and found a more homogeneous drug distribution in tumors of mice given repeated doses (5×8 mg/kg plus a 60 mg/kg dose than in those assigned only a single 60 mg/kg dose. The protocol can be readily applied to investigate anticancer drug distribution in neoplastic lesions and to develop strategies to optimize and enhance drug penetration through different tumor tissues.

  10. Direct analysis of pharmaceutical tablet formulations using Matrix-Assisted Laser Desorption/Ionisation Mass Spectrometry Imaging.

    Science.gov (United States)

    Earnshaw, Caroline J; Carolan, Vikki A; Richards, Don S; Clench, Malcolm R

    2010-06-15

    Matrix-Assisted Laser Desorption/Ionisation Mass Spectrometry Imaging (MALDI MSI) has been used to directly analyse a range of tablets in order to assess the homogeneity of the active drug compound throughout the excipients contained within the tablets studied. The information gained from the imaging experiments can be used to improve and gain a greater understanding of the manufacturing process; such knowledge will enable improvements in finished product quality to make safer and more efficacious tablet formulations. Commercially available and prescription tablet formulations have been analysed, including aspirin, paracetamol, sildenafil citrate (Viagra(R)) and a batch of tablets in development (tablet X: placebo; 1 mg; 3 mg and 6 mg). MALDI MSI provides semi-quantitative information that is related to ion abundance, therefore Principal Component Analysis (PCA), a multivariate analysis technique, has been used to differentiate between tablets containing different amounts of active drug ingredient. Aspects of sample preparation have also been investigated with regard to tablet shape and texture. The results obtained indicate that MALDI MSI can be used effectively to analyse the spatial distribution of the active pharmaceutical component (API) in pharmaceutical tablet formulations.

  11. Direct matrix-assisted laser desorption/ionization mass spectrometric imaging of cellulose and hemicellulose in Populus tissue.

    Science.gov (United States)

    Lunsford, Kyle Ann; Peter, Gary F; Yost, Richard A

    2011-09-01

    Imaging applied toward lignocellulosic materials requires high molecular specificity to map specific compounds within intact tissue. Although secondary ionization mass spectrometry (SIMS) and matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) with a single stage of MS have been used to image lignocellulosic biomass, the complexity of the plant tissue requires tandem MS, which limits the interpretation of simple MS. MALDI linear ion trap (LIT) tandem MS offers the high molecular specificity needed for lignocellulosic analyses. MALDI-LIT MS analyses of cellulose and xylan (hemicellulose) standards were performed to determine mass-to-charge ratios and fragmentation pathways for identification of these compounds in intact tissue. The MALDI-LIT-MS images of young Populus wood stem showed even distribution of both cellulose and hemicellulose ions; in contrast, the tandem MS images of cellulose and hemicellulose generated by plotting characteristic fragment ions resulted in drastically different images. This demonstrates that isobaric ions are present during MALDI-LIT-MS analyses of wood tissue and tandem MS is necessary to distinguish between isobaric species for selective imaging of carbohydrates in biomass.

  12. Titanium dioxide anatase as matrix for matrix-assisted laser desorption/ionization analysis of small molecules.

    Science.gov (United States)

    Castro, Ana L; Madeira, Paulo J Amorim; Nunes, Manuel R; Costa, Fernanda M; Florêncio, M Helena

    2008-12-01

    The use of inorganic species as assisting materials in matrix-assisted laser desorption/ionization (MALDI) analysis is an alternative approach to avoid interfering matrix ions in the low-mass region of the mass spectra. Reports of the application of inorganic species as matrices in MALDI analysis of small molecules are, however, scarce. Nevertheless, titanium dioxide (TiO(2)) powder has been reported to be a promising matrix medium. In this study we further explore the use of TiO(2) as a matrix for the MALDI analysis of low molecular weight compounds. We present results showing that nanosized TiO(2) anatase and TiO(2) rutile perform better as MALDI matrices than a commercial TiO(2) anatase/rutile mixture. Moreover, when using nanosized TiO(2) anatase as a matrix, high-quality mass spectra can be obtained with strong analyte signals and weak or non-existing matrix interference ions. Furthermore, our results show that the phase type plays an important role in the application of TiO(2) as a MALDI matrix.

  13. Targeted comparative proteomics by liquid chromatography/matrix-assisted laser desorption/ionization triple-quadrupole mass spectrometry.

    Science.gov (United States)

    Melanson, Jeremy E; Chisholm, Kenneth A; Pinto, Devanand M

    2006-01-01

    Here we report the first application of a matrix-assisted laser desorption/ionization (MALDI) triple-quadrupole mass spectrometer for targeted proteomics. Employing an amine-specific isotopic labelling approach, the technique was validated using five randomly selected bovine serum albumin peptides differentially labelled at known ratios. An indirect benefit of the isotopic labelling technique is a significant enhancement of the a1 ion in tandem mass (MS/MS) spectra of all peptides studied. Therefore, the a1 ion was selected as the fragment ion for multiple reaction monitoring (MRM) in all cases, eliminating tedious method development and optimization. Accurate quantification was achieved with an average relative standard deviation (RSD) of 5% (n = 5) and a detection limit of 14 amol. The technique was then applied to validate an important virulence biomarker of the fungal pathogen Candida albicans, which was not accurately quantified using global proteomics experiment employing two-dimensional liquid chromatography/electrospray ionization tandem mass spectrometry (2D-LC/ESI)-MS/MS. Using LC/MALDI-MRM analysis of five tryptic peptides, the protein PHR1 was found to be upregulated in the hyphal (pathogenic) form of C. albicans by a factor of 7.7 +/- 0.8.

  14. Carbapenemase Activity Detection by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry ▿

    Science.gov (United States)

    Hrabák, Jaroslav; Walková, Radka; Študentová, Vendula; Chudáčková, Eva; Bergerová, Tamara

    2011-01-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is used for the determination of molecular weights of different chemical compounds. We describe here the use of MALDI-TOF mass spectrometry to detect a carbapenem antibiotic, meropenem, and its degradation products. Buffered meropenem solution (0.1 mM Tris-HCl, pH 6.8) was mixed with an overnight culture of bacteria. After 3-h incubation, the reaction mixture was centrifuged, and the supernatant was analyzed by MALDI-TOF mass spectrometry. The presence or absence of peaks representing meropenem and its sodium salts was crucial. The average turnaround time of this test, considering the use of overnight culture, is 4 h. We validated this method for the detection of resistance to carbapenems in Enterobacteriaceae and Pseudomonas aeruginosa mediated by carbapenemase production. A total of 124 strains, including 30 carbapenemase-producing strains, were used in the study. The sensitivity of this method is 96.67%, with a specificity of 97.87%. Our results demonstrate the ability of this method to routinely detect carbapenemases in Enterobacteriaceae and Pseudomonas spp. in laboratories. This assay is comparable with a labor-intensive imipenem-hydrolyzing spectrophotometric assay that is a reference method for the detection of carbapenemase. As demonstrated here, MALDI-TOF mass spectrometry may be used in microbiological laboratories not only for microbial identification but also for other applications, such as studies of mechanisms of antibiotic resistance. PMID:21775535

  15. Analysis of Microbial Mixtures by Matrix-assisted Laser Desorption/Ionization time-of-flight Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Karen L.; Wunschel, Sharon C.; Jarman, Kristin H.; Valentine, Nancy B.; Petersen, Catherine E.; Kingsley, Mark T.; Zartolas, Kimberly A.; Saenz, Adam J.

    2002-12-15

    Many different laboratories are currently developing mass-spectrometric techniques to analyze and identify microorganisms. However, minimal work has been done with mixtures of bacteria. To demonstrate that microbial mixtures could be analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), mixed bacterial cultures were analyzed in a double-blind fashion. Nine different bacterial species currently in our MALDI-MS fingerprint library were used to generate 50 different simulated mixed bacterial cultures similar to that done for an initial blind study previously reported.(1) The samples were analyzed by MALDI-MS with automated data extraction and analysis algorithms developed in our laboratory. The components present in the sample were identified correctly to the species level in all but one of the samples. However, correctly eliminating closely related organisms was challenging for the current algorithms, especially in differentiating Serratia marcescens, Escherichia coli, and Yersinia enterocolitica, which have some similarities in their MALDI-MS fingerprints. Efforts to improve the specificity of the algorithms are in progress.

  16. Identification and localization of trauma-related biomarkers using matrix assisted laser desorption/ionization imaging mass spectrometry

    Science.gov (United States)

    Jones, Kirstin; Reilly, Matthew A.; Glickman, Randolph D.

    2017-02-01

    Current treatments for ocular and optic nerve trauma are largely ineffective and may have adverse side effects; therefore, new approaches are needed to understand trauma mechanisms. Identification of trauma-related biomarkers may yield insights into the molecular aspects of tissue trauma that can contribute to the development of better diagnostics and treatments. The conventional approach for protein biomarker measurement largely relies on immunoaffinity methods that typically can only be applied to analytes for which antibodies or other targeting means are available. Matrix assisted laser-assisted desorption/ionization imaging mass spectrometry (MALDI-IMS) is a specialized application of mass spectrometry that not only is well suited to the discovery of novel or unanticipated biomarkers, but also provides information about the spatial localization of biomarkers in tissue. We have been using MALDI-IMS to find traumarelated protein biomarkers in retina and optic nerve tissue from animal models subjected to ocular injury produced by either blast overpressure or mechanical torsion. Work to date by our group, using MALDI-IMS, found that the pattern of protein expression is modified in the injured ocular tissue as soon as 24 hr post-injury, compared to controls. Specific proteins may be up- or down-regulated by trauma, suggesting different tissue responses to a given injury. Ongoing work is directed at identifying the proteins affected and mapping their expression in the ocular tissue, anticipating that systematic analysis can be used to identify targets for prospective therapies for ocular trauma.

  17. Rapid differentiation of Panax ginseng and Panax quinquefolius by matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Lai, Ying-Han; So, Pui-Kin; Lo, Samual Chun-Lap; Ng, Eddy Wing Yin; Poon, Terence Chuen Wai; Yao, Zhong-Ping

    2012-11-13

    A matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS)-based method has been developed for rapid differentiation between Panax ginseng and Panax quinquefolius, two herbal medicines with similar chemical and physical properties but different therapeutic effects. This method required only a small quantity of samples, and the herbal medicines were analyzed by MALDI-MS either after a brief extraction step, or directly on the powder form or small pieces of raw samples. The acquired MALDI-MS spectra showed different patterns of ginsenosides and small chemical molecules between P. ginseng and P. quinquefolius, thus allowing unambiguous differentiation between the two Panax species based on the specific ions, intensity ratios of characteristic ions or principal component analysis. The approach could also be used to differentiate red ginseng or P. quinquefolius adulterated with P. ginseng from pure P. ginseng and pure Panax quinquefolium. The intensity ratios of characteristic ions in the MALDI-MS spectra showed high reproducibility and enabled quantitative determination of ginsenosides in the herbal samples and percentage of P. quinquefolius in the adulterated binary mixture. The method is simple, rapid, robust, and can be extended for analysis of other herbal medicines. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Identification and Classification of Rhizobia by Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry.

    Science.gov (United States)

    Jia, Rui Zong; Zhang, Rong Juan; Wei, Qing; Chen, Wen Feng; Cho, Il Kyu; Chen, Wen Xin; Li, Qing X

    Mass spectrometry (MS) has been widely used for specific, sensitive and rapid analysis of proteins and has shown a high potential for bacterial identification and characterization. Type strains of four species of rhizobia and Escherichia coli DH5α were employed as reference bacteria to optimize various parameters for identification and classification of species of rhizobia by matrix-assisted laser desorption/ionization time-of-flight MS (MALDI TOF MS). The parameters optimized included culture medium states (liquid or solid), bacterial growth phases, colony storage temperature and duration, and protein data processing to enhance the bacterial identification resolution, accuracy and reliability. The medium state had little effects on the mass spectra of protein profiles. A suitable sampling time was between the exponential phase and the stationary phase. Consistent protein mass spectral profiles were observed for E. coli colonies pre-grown for 14 days and rhizobia for 21 days at 4°C or 21°C. A dendrogram of 75 rhizobial strains of 4 genera was constructed based on MALDI TOF mass spectra and the topological patterns agreed well with those in the 16S rDNA phylogenetic tree. The potential of developing a mass spectral database for all rhizobia species was assessed with blind samples. The entire process from sample preparation to accurate identification and classification of species required approximately one hour.

  19. Effect of surface-enhanced laser desorption/ionization time-of-flight mass spectrometry on identifing biomarkers of endometriosis

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong; FENG Jie; CHANG Xiao-hong; LI Zhong-xing; WU Xiao-yi; CUI Heng

    2009-01-01

    Background Endometriosis is a common gynecological disease. This study aimed to screen proteins that were expressed differently in patients with endometriosis versus normal controls using proteomic techniques, surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS).Methods Protein chip SELDI-TOF-MS combines the advantages of microarray and mass spectrometry, and can screen latent markers in sera of patients with endometriosis. Serum samples from patients and normal volunteers were analyzed by SELDI-TOF-MS.Results After comparing the serum protein spectra of 36 patients with 24 normal controls, 24 differently expressed potential biomarkers (P <0.01) were identified. Using Biomarker Pattern software, we established a tree model of the 60 serum protein spectra. When using the three biomarkers to classify the samples, the sensitivity for diagnosing endometriosis was 91.7%, specificity was 95.8%, and coincidence rate was 93.3%. Then we used serum samples from 12 patients and 8 normal controls to validate the tree model and report the sensitivity for diagnosing endometriosis was 91.7%, specificity was 75%, and coincidence rate was 85%.Conclusions SELDI-TOF-MS may be a useful tool in high-risk population screening for endometriosis. The identification and application of the biomarkers need to further study.

  20. Matrix-assisted laser desorption/ionization mass spectrometric analysis of aliphatic biodegradable photoluminescent polymers using new ionic liquid matrices.

    Science.gov (United States)

    Serrano, Carlos A; Zhang, Yi; Yang, Jian; Schug, Kevin A

    2011-05-15

    In this study, two novel ionic liquid matrices (ILMs), N,N-diisopropylethylammonium 3-oxocoumarate and N,N-diisopropylethylammonium dihydroxymonooxoacetophenoate, were tested for the structural elucidation of recently developed aliphatic biodegradable polymers by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The polymers, formed by a condensation reaction of three components, citric acid, octane diol, and an amino acid, are fluorescent, but the exact mechanism behind their luminescent properties has not been fully elucidated. In the original studies, which introduced the polymer class (J. Yang et al., Proc. Natl. Acad. Sci. USA 2009, 106, 10086-10091), a hyper-conjugated cyclic structure was proposed as the source for the photoluminescent behavior. With the use of the two new ILMs, we present evidence that supports the presence of the proposed cyclization product. In addition, the new ILMs, when compared with a previously established ILM, N,N-diisopropylethylammonium α-cyano-3-hydroxycinnimate, provided similar signal intensities and maintained similar spectral profiles. This research also established that the new ILMs provided good spot-to-spot reproducibility and high ionization efficiency compared with corresponding crystalline matrix preparations. Many polymer features revealed through the use of the ILMs could not be observed with crystalline matrices. Ultimately, the new ILMs highlighted the composition of the synthetic polymers, as well as the loss of water that was expected for the formation of the proposed cyclic structure on the polymer backbone.

  1. Silica nanoparticles pre-spotted onto target plate for laser desorption/ionization mass spectrometry analyses of peptides.

    Science.gov (United States)

    Dupré, Mathieu; Cantel, Sonia; Durand, Jean-Olivier; Martinez, Jean; Enjalbal, Christine

    2012-09-05

    We report on the simple deposition of Stöber silica nanoparticles (SiO(2) NPs) on conventional MALDI target plate for high throughput laser desorption/ionization mass spectrometry (LDI-MS) analyses of peptide mixtures with sensitivity in the femtomolar range. This low-cost easily prepared material allowed straightforward LDI experiments by deposition of the studied samples directly onto a pre-spotted MALDI plate. This analytical strategy can be performed in any laboratory equipped with a MALDI-TOF instrument. All key benefits of organic matrix-free technologies were satisfied while maintaining a high level of detection performances (sensitivity and reproducibility/repeatability). In particular, sample preparation was simple and detection in the low mass range was not hampered by matrix ions. Imaging studies were undertaken to query sample dispersion into the inert SiO(2) NPs and to help into the search of the best experimental conditions producing homogeneous analyte distribution within the deposit. In contrast to commercial disposable LDI targets designed for single use and requiring an adaptor such as NALDI™, the proposed SiO(2) NPs pre-spotting on a MALDI target plate allowed very easily switching between MALDI and LDI experiments. They can be conducted either simultaneously (positions with an organic matrix or SiO(2) NPs) or in the row (support prepared in advance, stored and washed after use). The overall cost and versatility of the methodology made it very attractive to MALDI users in many domains (peptidomics, proteomics, metabolomics).

  2. Principles of hydrogen radical mediated peptide/protein fragmentation during matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Asakawa, Daiki

    2016-07-01

    Matrix-assisted laser desorption/ionization in-source decay (MALDI-ISD) is a very easy way to obtain large sequence tags and, thereby, reliable identification of peptides and proteins. Recently discovered new matrices have enhanced the MALDI-ISD yield and opened new research avenues. The use of reducing and oxidizing matrices for MALDI-ISD of peptides and proteins favors the production of fragmentation pathways involving "hydrogen-abundant" and "hydrogen-deficient" radical precursors, respectively. Since an oxidizing matrix provides information on peptide/protein sequences complementary to that obtained with a reducing matrix, MALDI-ISD employing both reducing and oxidizing matrices is a potentially useful strategy for de novo peptide sequencing. Moreover, a pseudo-MS(3) method provides sequence information about N- and C-terminus extremities in proteins and allows N- and C-terminal side fragments to be discriminated within the complex MALDI-ISD mass spectrum. The combination of high mass resolution of a Fourier transform-ion cyclotron resonance (FTICR) analyzer and the software suitable for MALDI-ISD facilitates the interpretation of MALDI-ISD mass spectra. A deeper understanding of the MALDI-ISD process is necessary to fully exploit this method. Thus, this review focuses first on the mechanisms underlying MALDI-ISD processes, followed by a discussion of MALDI-ISD applications in the field of proteomics. © 2014 Wiley Periodicals, Inc., Mass Spec Rev 35:535-556, 2016.

  3. Characterization of aromaticity in analogues of titan's atmospheric aerosols with two-step laser desorption ionization mass spectrometry

    Science.gov (United States)

    Mahjoub, Ahmed; Schwell, Martin; Carrasco, Nathalie; Benilan, Yves; Cernogora, Guy; Szopa, Cyril; Gazeau, Marie-Claire

    2016-10-01

    The role of polycyclic aromatic hydrocarbons (PAH) and Nitrogen containing PAH (PANH) as intermediates of aerosol production in the atmosphere of Titan has been a subject of controversy for a long time. An analysis of the atmospheric emission band observed by the Visible and Infrared Mapping Spectrometer (VIMS) at 3.28 μm suggests the presence of neutral polycyclic aromatic species in the upper atmosphere of Titan. These molecules are seen as the counter part of negative and positive aromatics ions suspected by the Plasma Spectrometer onboard the Cassini spacecraft, but the low resolution of the instrument hinders any molecular speciation. In this work we investigate the specific aromatic content of Titan's atmospheric aerosols through laboratory simulations. We report here the selective detection of aromatic compounds in tholins, Titan's aerosol analogs, produced with a capacitively coupled plasma in a N2:CH4 95:5 gas mixture. For this purpose, Two-Step Laser Desorption Ionization Time-of-Flight Mass Spectrometry (L2DI-TOF-MS) technique is used to analyze the so produced analogs. This analytical technique is based on the ionization of molecules by Resonance Enhanced Multi-Photon Ionization (REMPI) using a λ=248 nm wavelength laser which is selective for aromatic species. This allows for the selective identification of compounds having at least one aromatic ring. Our experiments show that tholins contain a trace amount of small PAHs with one to three aromatic rings. Nitrogen containing PAHs (PANHs) are also detected as constituents of tholins. Molecules relevant to astrobiology are detected as is the case of the substituted DNA base adenine.

  4. Differentiation of Microbial Species and Strains in Coculture Biofilms by Multivariate Analysis of Laser Desorption Postionization Mass Spectra

    Energy Technology Data Exchange (ETDEWEB)

    University of Illinois at Chicago; Montana State University; Bhardwaj, Chhavi; Cui, Yang; Hofstetter, Theresa; Liu, Suet Yi; Bernstein, Hans C.; Carlson, Ross P.; Ahmed, Musahid; Hanley, Luke

    2013-04-01

    7.87 to 10.5 eV vacuum ultraviolet (VUV) photon energies were used in laser desorption postionization mass spectrometry (LDPI-MS) to analyze biofilms comprised of binary cultures of interacting microorganisms. The effect of photon energy was examined using both tunable synchrotron and laser sources of VUV radiation. Principal components analysis (PCA) was applied to the MS data to differentiate species in Escherichia coli-Saccharomyces cerevisiae coculture biofilms. PCA of LDPI-MS also differentiated individual E. coli strains in a biofilm comprised of two interacting gene deletion strains, even though these strains differed from the wild type K-12 strain by no more than four gene deletions each out of approximately 2000 genes. PCA treatment of 7.87 eV LDPI-MS data separated the E. coli strains into three distinct groups two ?pure? groups and a mixed region. Furthermore, the ?pure? regions of the E. coli cocultures showed greater variance by PCA when analyzed by 7.87 eV photon energies than by 10.5 eV radiation. Comparison of the 7.87 and 10.5 eV data is consistent with the expectation that the lower photon energy selects a subset of low ionization energy analytes while 10.5 eV is more inclusive, detecting a wider range of analytes. These two VUV photon energies therefore give different spreads via PCA and their respective use in LDPI-MS constitute an additional experimental parameter to differentiate strains and species.

  5. Benefits of 2.94 μm infrared matrix-assisted laser desorption/ionization for analysis of labile molecules by Fourier transform mass spectrometry

    DEFF Research Database (Denmark)

    Budnik, Bogdan A.; Jensen, Kenneth Bendix; Jørgensen, Thomas J. D.

    2000-01-01

    A 2.94 microm Er:YAG laser was used together with a commercial Fourier transform mass spectrometer to study labile biomolecules. The combination has shown superior performance over conventional 337 nm ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI) Fourier transform mass...... spectrometry (FTMS), especially for the analysis of peptides with post-translational modifications. With succinic acid as a matrix, the sensitivity of the single-shot analysis was increased by an order of magnitude to the low femtomole level, with significantly less fragmentation observed. Intact molecular...

  6. Online laser desorption-multiphoton postionization mass spectrometry of individual aerosol particles: molecular source indicators for particles emitted from different traffic-related and wood combustion sources.

    Science.gov (United States)

    Bente, Matthias; Sklorz, Martin; Streibel, Thorsten; Zimmermann, Ralf

    2008-12-01

    Direct inlet aerosol mass spectrometry plays an increasingly important role in applied and fundamental aerosol and nanoparticle research. Laser desorption/ionization (LDI) based techniques for single particle time-of-flight mass spectrometry (LDI-SP-TOFMS) are a promising approach in the chemical analysis of single aerosol particles, especially for the detection of inorganic species and distinction of particle classes. However, until now the detection of molecular organic compounds on a single particle basis has been difficult due to the high laser power densities which are required for the LDI process as well as due to the inherent matrix effects associated with this ionization technique. By the application of a two-step approach, where an IR desorption laser pulse is applied to perform a gentle desorption of organic material from the single particle surface and a second UV-laser performs the soft ionization of the desorbed species, this drawback of laser based single particles mass spectrometry can be overcome. The postionization of the desorbed molecules has been accomplished in this work by resonance enhanced multiphoton ionization (REMPI) using a KrF excimer laser (248 nm). REMPI allows an almost fragmentation free trace analysis of polycyclic aromatic hydrocarbons (PAHs) and their derivatives from individual single particles (laser desorption-REMPI postionization-single particle-time-of-flight mass spectrometry or LD-REMPI-SP-TOFMS). Crucial system parameters of the home-built aerosol mass spectrometer such as the power densities and the relative timing of both lasers were optimized with respect to the detectability of particle source specific organic signatures using well characterized standard particles. In a second step, the LD-REMPI-SP-TOFMS system was applied to analyze different real world aerosols (spruce wood combustion, gasoline car exhaust, beech wood combustion, and diesel car exhaust). It was possible to distinguish the particles from different

  7. Field enhancement induced laser ablation

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Maibohm, Christian; Kjelstrup-Hansen, Jakob

    Sub-diffraction spatially resolved, quantitative mapping of strongly localized field intensity enhancement on gold nanostructures via laser ablation of polymer thin films is reported. Illumination using a femtosecond laser scanning microscope excites surface plasmons in the nanostructures...

  8. Electric field induced desorption of bacteria from a conditioning film covered substratum.

    Science.gov (United States)

    Poortinga, A T; Smit, J; van der Mei, H C; Busscher, H J

    2001-12-01

    Desorption of three oral bacterial strains from a salivary conditioning film on an indium tin oxide electrode during application of a positive (bacterial adhesion to the anode) or a negative electric current was studied in a parallel plate flow chamber. Bacterial adhesion was from a flowing suspension of high ionic strength, after which the bacterial suspension was replaced by a low ionic strength solution without bacteria and currents ranging from -800 to +800 microA were applied. Streptococcus oralis J22 desorbed during application of a positive and negative electric current with a desorption probability that increased with increasing electric current. Two actinomyces strains, however, could not be stimulated to desorb by the electric currents applied. The desorption forces acting on adhering bacteria are electroosmotic in origin and working parallel to the electrode surface in case of a positive current, whereas they are electrophoretic and electrostatic in origin and working perpendicular to the surface in case of a negative current. By comparison of the effect of positive and negative electric currents, it can be concluded that parallel forces are more effective in stimulating bacterial desorption than perpendicular forces. The results of this study point to a new pathway of cleaning industrial and biomedical surfaces without the use of detergents or biocides.

  9. Electric field induced desorption of bacteria from a conditioning film covered substratum

    NARCIS (Netherlands)

    Poortinga, AT; Smit, J; van der Mei, HC; Busscher, HJ

    2001-01-01

    Desorption of three oral bacterial strains from a salivary conditioning film on an indium tin oxide electrode during application of a positive (bacterial adhesion to the anode) or a negative electric current was studied in a parallel plate flow chamber. Bacterial adhesion was from a flowing suspensi

  10. Large molecular mass materials in coal-derived liquids by {sup 252}Cf-plasma and matrix-assisted laser desorption mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Domin, M.; Li, S.; Lazaro, M.-J.; Herod, A.A.; Larsen, J.W.; Kandiyoti, R. [School of Pharmacy, London (United Kingdom). Dept. of Parmaceutical and Biological Chemistry

    1998-05-01

    The paper compares responses of {sup 252}Cf-plasma desorption MS (PD-MS) and matrix-assisted laser desorption (MALDI) MS to identical samples. The two pairs of samples selected for the comparison were known from previous work to differ significantly in their high mass contents. MALDI-MS showed large differences in MM distributions within both pairs of samples. The PD-MS data showed a degree of similarity between one pair of samples (pyridine soluble/insoluble fractions of a coal tar pitch); for the second pair (a coal extract and its hydrocracked product), trends from the two MS techniques agreed closely. The MM range observed by PD-MS was somewhat narrower, extending to between 3000 and 5000 u. Significant differences within pairs of samples were observed by SEC and by UV-fluorescence spectroscopy, providing somewhat closer agreement with the MALDI spectra. The two MS instruments differ in two important respects: the ionization system (i.e., plasma vs laser desorption) and the maximum available ion extraction voltage: 30 kV for the MALDI-MS instrument and 15 kV for the PD-MS. The comparison of plasma vs laser desorption mass spectroscopy could not therefore take place at high ion extraction voltages. Work at up to 30 kV in the MALDI instrument indicated better sensitivity to high-mass materials at higher ion extraction voltages. The qualitative similarity of results from the two MS techniques is nevertheless apparent; the range of MMs observed in PD-MS as well as in MALDI-MS were, furthermore, far larger than those reported by any MS technique, to date. 38 refs., 6 figs., 1 tab.

  11. Atmospheric pressure laser desorption/ionization using a 6-7 µm-band mid-infrared tunable laser and liquid water matrix.

    Science.gov (United States)

    Hiraguchi, Ryuji; Hazama, Hisanao; Masuda, Katsuyoshi; Awazu, Kunio

    2015-01-01

    Due to the characteristic absorption peaks in the IR region, various molecules can be used as a matrix for infrared matrix-assisted laser desorption/ionization (IR-MALDI). Especially in the 6-7 µm-band IR region, solvents used as the mobile phase for liquid chromatography have absorption peaks that correspond to their functional groups, such as O-H, C=O, and CH3. Additionally, atmospheric pressure (AP) IR-MALDI, which is applicable to liquid-state samples, is a promising technique to directly analyze untreated samples. Herein we perform AP-IR-MALDI mass spectrometry of a peptide, angiotensin II, using a mid-IR tunable laser with a tunable wavelength range of 5.50-10.00 µm and several different matrices. The wavelength dependences of the ion signal intensity of [M + H](+) of the peptide are measured using a conventional solid matrix, α-cyano-4-hydroxycinnamic acid (CHCA) and a liquid matrix composed of CHCA and 3-aminoquinoline. Other than the O-H stretching and bending vibration modes, the characteristic absorption peaks are useful for AP-IR-MALDI. Peptide ions are also observed from an aqueous solution of the peptide without an additional matrix, and the highest peak intensity of [M + H](+) is at 6.00 µm, which is somewhat shorter than the absorption peak wavelength of liquid water corresponding to the O-H bending vibration mode. Moreover, long-lasting and stable ion signals are obtained from the aqueous solution. AP-IR-MALDI using a 6-7 µm-band IR tunable laser and solvents as the matrix may provide a novel on-line interface between liquid chromatography and mass spectrometry.

  12. Probing of Metabolites in Finely Powdered Plant Material by Direct Laser Desorption Ionization Mass Spectrometry

    Science.gov (United States)

    Musharraf, Syed Ghulam; Ali, Arslan; Choudhary, M. Iqbal; Atta-ur-Rahman

    2014-04-01

    Natural products continue to serve as an important source of novel drugs since the beginning of human history. High-throughput techniques, such as MALDI-MS, can be techniques of choice for the rapid screening of natural products in plant materials. We present here a fast and reproducible matrix-free approach for the direct detection of UV active metabolites in plant materials without any prior sample preparation. The plant material is mechanically ground to a fine powder and then sieved through different mesh sizes. The collected plant material is dispersed using 1 μL solvent on a target plate is directly exposed to Nd:YAG 335 nm laser. The strategy was optimized for the analysis of plant metabolites after study of the different factors affecting the reproducibility and effectiveness of the analysis, including particle sizes effects, types of solvents used to disperse the sample, and the part of the plant analyzed. Moreover, several plant species, known for different classes of metabolites, were screened to establish the generality of the approach. The developed approach was validated by the characterization of withaferin A and nicotine in the leaves of Withania somnifera and Nicotiana tabacum, respectively, through comparison of its MS/MS data with the standard compound. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) techniques were used for the tissue imaging purposes. This approach can be used to directly probe small molecules in plant materials as well as in herbal and pharmaceutical formulations for fingerprinting development.

  13. FOREWORD: The 12th International Workshop on Desorption Induced by Electronic Transitions (DIET XII) (Pine Mountain, Georgia, USA, 19-23 April 2009) The 12th International Workshop on Desorption Induced by Electronic Transitions (DIET XII) (Pine Mountain, Georgia, USA, 19-23 April 2009)

    Science.gov (United States)

    Orlando, Thomas M.; Diebold, Ulrike

    2010-03-01

    The 12th International Workshop on Desorption Induced by Electronic Transitions (DIET XII) took place from 19-23 April 2009 in Pine Mountain, Georgia, USA. This was the 12th conference in a strong and vibrant series, which dates back to the early 1980s. DIET XII continued the tradition of exceptional interdisciplinary science and focused on the study of desorption and dynamics induced by electronic excitations of surfaces and interfaces. The format involved invited lectures, contributed talks and a poster session on the most recent developments and advances in this area of surface physics. The Workshop International Steering Committee and attendees wish to dedicate DIET XII to the memory of the late Professor Theodore (Ted) Madey. Ted was one of the main pioneers of this field and was one of the primary individuals working to keep this area of science exciting and adventurous. His overall contributions to surface science were countless and his contributions to the DIET field and community were enormous. He is missed and remembered by many friends and colleagues throughout the world. The papers collected in this issue cover many of the highlights of DIET XII. Topics include ultrafast electron transfer at surfaces and interfaces, quantum and spatially resolved mapping of surface dynamics and desorption, photon-, electron- and ion-beam induced processes at complex interfaces, the role of non-thermal desorption in astrochemistry and astrophysics and laser-/ion-based methods of examining soft matter and biological media. Although the workshop attracted many scientists active in the general area of non-thermal surface processes, DIET XII also attracted many younger scientists (i.e., postdoctoral fellows, advanced graduate students, and a select number of advanced undergraduate students). This field has had an impact in a number of areas including nanoscience, device physics, astrophysics, and now biophysics. We believe that this special issue of Journal of Physics

  14. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for rapid identification of fungal rhinosinusitis pathogens.

    Science.gov (United States)

    Huang, Yanfei; Wang, Jinglin; Zhang, Mingxin; Zhu, Min; Wang, Mei; Sun, Yufeng; Gu, Haitong; Cao, Jingjing; Li, Xue; Zhang, Shaoya; Lu, Xinxin

    2017-03-01

    Filamentous fungi are among the most important pathogens, causing fungal rhinosinusitis (FRS). Current laboratory diagnosis of FRS pathogens mainly relies on phenotypic identification by culture and microscopic examination, which is time consuming and expertise dependent. Although matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS has been employed to identify various fungi, its efficacy in the identification of FRS fungi is less clear. A total of 153 FRS isolates obtained from patients were analysed at the Clinical Laboratory at the Beijing Tongren Hospital affiliated to the Capital Medical University, between January 2014 and December 2015. They were identified by traditional phenotypic methods and Bruker MALDI-TOF MS (Bruker, Biotyper version 3.1), respectively. Discrepancies between the two methods were further validated by sequencing. Among the 153 isolates, 151 had correct species identification using MALDI-TOF MS (Bruker, Biot 3.1, score ≥2.0 or 2.3). MALDI-TOF MS enabled identification of some very closely related species that were indistinguishable by conventional phenotypic methods, including 1/10 Aspergillus versicolor, 3/20 Aspergillus flavus, 2/30 Aspergillus fumigatus and 1/20 Aspergillus terreus, which were misidentified by conventional phenotypic methods as Aspergillus nidulans, Aspergillus oryzae, Aspergillus japonicus and Aspergillus nidulans, respectively. In addition, 2/2 Rhizopus oryzae and 1/1 Rhizopus stolonifer that were identified only to the genus level by the phenotypic method were correctly identified by MALDI-TOF MS. MALDI-TOF MS is a rapid and accurate technique, and could replace the conventional phenotypic method for routine identification of FRS fungi in clinical microbiology laboratories.

  15. Identification of beer-spoilage bacteria using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Wieme, Anneleen D; Spitaels, Freek; Aerts, Maarten; De Bruyne, Katrien; Van Landschoot, Anita; Vandamme, Peter

    2014-08-18

    Applicability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of beer-spoilage bacteria was examined. To achieve this, an extensive identification database was constructed comprising more than 4200 mass spectra, including biological and technical replicates derived from 273 acetic acid bacteria (AAB) and lactic acid bacteria (LAB), covering a total of 52 species, grown on at least three growth media. Sequence analysis of protein coding genes was used to verify aberrant MALDI-TOF MS identification results and confirmed the earlier misidentification of 34 AAB and LAB strains. In total, 348 isolates were collected from culture media inoculated with 14 spoiled beer and brewery samples. Peak-based numerical analysis of MALDI-TOF MS spectra allowed a straightforward species identification of 327 (94.0%) isolates. The remaining isolates clustered separately and were assigned through sequence analysis of protein coding genes either to species not known as beer-spoilage bacteria, and thus not present in the database, or to novel AAB species. An alternative, classifier-based approach for the identification of spoilage bacteria was evaluated by combining the identification results obtained through peak-based cluster analysis and sequence analysis of protein coding genes as a standard. In total, 263 out of 348 isolates (75.6%) were correctly identified at species level and 24 isolates (6.9%) were misidentified. In addition, the identification results of 50 isolates (14.4%) were considered unreliable, and 11 isolates (3.2%) could not be identified. The present study demonstrated that MALDI-TOF MS is well-suited for the rapid, high-throughput and accurate identification of bacteria isolated from spoiled beer and brewery samples, which makes the technique appropriate for routine microbial quality control in the brewing industry. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Localization of ergot alkaloids in sclerotia of Claviceps purpurea by matrix-assisted laser desorption/ionization mass spectrometry imaging.

    Science.gov (United States)

    Dopstadt, Julian; Vens-Cappell, Simeon; Neubauer, Lisa; Tudzynski, Paul; Cramer, Benedikt; Dreisewerd, Klaus; Humpf, Hans-Ulrich

    2017-02-01

    The fungus Claviceps purpurea produces highly toxic ergot alkaloids and accumulates these in the hardened bodies of fungal mycelium. These so-called sclerotia, or ergot bodies, replace the crop seed of infected plants, which can include numerous important food- and feedstuff such as rye and wheat. While several studies have explored details of the infection process and development of ergot bodies, little information is available on the spatial distribution of the mycotoxins in the sclerotia. Here we used matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) at a lateral resolution of 35 μm to visualize the distribution of two representative alkaloids, ergocristine and ergometrine, produced by Ecc93 and Gal 310 variants of C. purpurea, respectively, after infection of rye. To improve cryosectioning of this fragile biological material tissue with complex texture, we developed a practical embedding protocol based on cellulose polymers. The MALDI-MS images recorded from the so produced intact tissues sections revealed that ergometrine exhibited a relatively homogeneous distribution throughout the ergot body, whereas ergocristine was found to be enriched in the proximal region. This finding can be correlated to the morphological development of sclerotia as ergot alkaloids are only produced in the sphacelial stage. The ability to localize toxins and other secondary metabolites in intact sections of crop-infecting fungi with high lateral resolution renders MALDI-MSI a powerful tool for investigating biosynthetic pathways and for obtaining a deeper understanding of the parasite-host interaction. Graphical abstract Workflow for identification and spatial localization of ergot alkaloids in infected rye grains.

  17. Rapid Identification of the Foodborne Pathogen Trichinella spp. by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

    Science.gov (United States)

    Mayer-Scholl, Anne; Murugaiyan, Jayaseelan; Neumann, Jennifer; Bahn, Peter; Reckinger, Sabine; Nöckler, Karsten

    2016-01-01

    Human trichinellosis occurs through consumption of raw or inadequately processed meat or meat products containing larvae of the parasitic nematodes of the genus Trichinella. Currently, nine species and three genotypes are recognized, of which T. spiralis, T. britovi and T. pseudospiralis have the highest public health relevance. To date, the differentiation of the larvae to the species and genotype level is based primarily on molecular methods, which can be relatively time consuming and labor intensive. Due to its rapidness and ease of use a matrix assisted laser desorption / ionization time of flight mass spectrometry (MALDI-TOF MS) reference spectra database using Trichinella strains of all known species and genotypes was created. A formicacid/acetonitrile protein extraction was carried out after pooling 10 larvae of each Trichinella species and genotype. Each sample was spotted 9 times using α-cyano 4-hydoxy cinnamic acid matrix and a MicroFlex LT mass spectrometer was used to acquire 3 spectra (m/z 2000 to 20000 Da) from each spot resulting in 27 spectra/species or genotype. Following the spectra quality assessment, Biotyper software was used to create a main spectra library (MSP) representing nine species and three genotypes of Trichinella. The evaluation of the spectra generated by MALDI-TOF MS revealed a classification which was comparable to the results obtained by molecular methods. Also, each Trichinella species utilized in this study was distinct and distinguishable with a high confidence level. Further, different conservation methods such as freezing and conservation in alcohol and the host species origin of the isolated larvae did not have a significant influence on the generated spectra. Therefore, the described MALDI-TOF MS can successfully be implemented for both genus and species level identification and represents a major step forward in the use of this technique in foodborne parasitology.

  18. Large-Scale Metabolite Analysis of Standards and Human Serum by Laser Desorption Ionization Mass Spectrometry from Silicon Nanopost Arrays.

    Science.gov (United States)

    Korte, Andrew R; Stopka, Sylwia A; Morris, Nicholas; Razunguzwa, Trust; Vertes, Akos

    2016-09-20

    The unique challenges presented by metabolomics have driven the development of new mass spectrometry (MS)-based techniques for small molecule analysis. We have previously demonstrated silicon nanopost arrays (NAPA) to be an effective substrate for laser desorption ionization (LDI) of small molecules for MS. However, the utility of NAPA-LDI-MS for a wide range of metabolite classes has not been investigated. Here we apply NAPA-LDI-MS to the large-scale acquisition of high-resolution mass spectra and tandem mass spectra from a collection of metabolite standards covering a range of compound classes including amino acids, nucleotides, carbohydrates, xenobiotics, lipids, and other classes. In untargeted analysis of metabolite standard mixtures, detection was achieved for 374 compounds and useful MS/MS spectra were obtained for 287 compounds, without individual optimization of ionization or fragmentation conditions. Metabolite detection was evaluated in the context of 31 metabolic pathways, and NAPA-LDI-MS was found to provide detection for 63% of investigated pathway metabolites. Individual, targeted analysis of the 20 common amino acids provided detection of 100% of the investigated compounds, demonstrating that improved coverage is possible through optimization and targeting of individual analytes or analyte classes. In direct analysis of aqueous and organic extracts from human serum samples, spectral features were assigned to a total of 108 small metabolites and lipids. Glucose and amino acids were quantitated within their physiological concentration ranges. The broad coverage demonstrated by this large-scale screening experiment opens the door for use of NAPA-LDI-MS in numerous metabolite analysis applications.

  19. Laser desorption ionization-time-of-flight mass analysis of perfluoropolyether monolayer directly from hard disk medium surface.

    Science.gov (United States)

    Kudo, Toshiji; Macht, Marcus; Kuroda, Masami

    2011-07-15

    Modern life is dependent on computer technology, and because the volume of digital data in the world is increasing rapidly, the importance of data storage devices is also increasing rapidly. Among them, demands for magnetic disk drive well-known as hard disk drives is quite huge and information recording density on the disk media is continuing to grow dramatically. For the research and development of the magnetic disk media, it is critical to investigate and characterize the lubricant layer formed on the disk media surface. However, it is difficult because the layer is only a monolayer which has only approximately 1 nm thickness in many cases. Although matrix-assisted laser desorption ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) measurements of monolayers have already been reported (Su, J.; Mrksich, M. Langmuir, 2003, 19, 4867-4870), lubricants used here are (co)polymers which have molecular weight distributions and are mixtures of various degrees of polymerization. This can reduce the sensitivity of MS measurement because the number (or density) of distinct single molecular species is lower than for homogeneous samples. In this report, direct measurement and characterization of lubricant monolayers using the LDI-TOF-MS instrument is performed to gain insight into detailed information like average molecular weight, polymer distribution, and two-dimensional mapping directly from magnetic disk monolayers. To our knowledge, this is the first time such information was acquired directly from hard disk media. The technique reported here might open up new possibilities also for investigations of various electronic devices other than magnetic hard disks.

  20. Rapid Identification of the Foodborne Pathogen Trichinella spp. by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Anne Mayer-Scholl

    Full Text Available Human trichinellosis occurs through consumption of raw or inadequately processed meat or meat products containing larvae of the parasitic nematodes of the genus Trichinella. Currently, nine species and three genotypes are recognized, of which T. spiralis, T. britovi and T. pseudospiralis have the highest public health relevance. To date, the differentiation of the larvae to the species and genotype level is based primarily on molecular methods, which can be relatively time consuming and labor intensive. Due to its rapidness and ease of use a matrix assisted laser desorption / ionization time of flight mass spectrometry (MALDI-TOF MS reference spectra database using Trichinella strains of all known species and genotypes was created. A formicacid/acetonitrile protein extraction was carried out after pooling 10 larvae of each Trichinella species and genotype. Each sample was spotted 9 times using α-cyano 4-hydoxy cinnamic acid matrix and a MicroFlex LT mass spectrometer was used to acquire 3 spectra (m/z 2000 to 20000 Da from each spot resulting in 27 spectra/species or genotype. Following the spectra quality assessment, Biotyper software was used to create a main spectra library (MSP representing nine species and three genotypes of Trichinella. The evaluation of the spectra generated by MALDI-TOF MS revealed a classification which was comparable to the results obtained by molecular methods. Also, each Trichinella species utilized in this study was distinct and distinguishable with a high confidence level. Further, different conservation methods such as freezing and conservation in alcohol and the host species origin of the isolated larvae did not have a significant influence on the generated spectra. Therefore, the described MALDI-TOF MS can successfully be implemented for both genus and species level identification and represents a major step forward in the use of this technique in foodborne parasitology.

  1. Exploring the frontiers of synthetic eumelanin polymers by high-resolution matrix-assisted laser/desorption ionization mass spectrometry.

    Science.gov (United States)

    Reale, Samantha; Crucianelli, Marcello; Pezzella, Alessandro; d'Ischia, Marco; De Angelis, Francesco

    2012-01-01

    New trends in material science and nanotechnologies have spurred growing interest in eumelanins black insoluble biopolymers derived by tyrosinase-catalysed oxidation of tyrosine via 5,6-dihydroxyindole (DHI) and its 2-carboxylic acid (DHICA). Efficient antioxidant and photoprotective actions, associated with peculiar optoelectronic properties, are recognised as prominent functions of eumelanin macromolecules within the human and mammalian pigmentary system, making them unique candidates for the realisation of innovative bio-inspired functional soft materials, with structure-based physical-chemical properties. An unprecedented breakthrough into the mechanism of synthetic eumelanin buildup has derived from a detailed investigation of the oxidative polymerization of DHI and its N-methyl derivative (NMDHI) by linear and reflectron matrix-assisted laser/desorption ionization mass spectrometry. Regular collections of oligomers of increasing masses, spanning the entire m/z ranges up to 5000 Da (>30-mer) and 8000 Da (> 50-mer) for the two building blocks, respectively, were disclosed. It is the first time that the in vitro polymerisation of dihydroxyindoles to form synthetic eumelanins is explored up to its high mass limits, giving at the same time information on the polymerisation mode, whether it follows a stepwise pattern (being this the conclusion in our case) or a staking sequencing of small-sized entities. It also highlighted the influence of the N-methyl substituent on the polymerization process; this opens the way to the production of N-functionalized, synthetic eumelanin-inspired soft materials, for possible future technological applications. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Rapid screening of mixed edible oils and gutter oils by matrix-assisted laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Tsz-Tsun; So, Pui-Kin; Zheng, Bo [Food Safety and Technology Research Centre, State Key Laboratory of Chirosciences and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong Special Administrative Region (China); Shenzhen Key Laboratory of Food Biological Safety Control and State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation), Shenzhen Research Institute of The Hong Kong Polytechnic University, Shenzhen (China); Yao, Zhong-Ping, E-mail: zhongping.yao@polyu.edu.hk [Food Safety and Technology Research Centre, State Key Laboratory of Chirosciences and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong Special Administrative Region (China); Shenzhen Key Laboratory of Food Biological Safety Control and State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation), Shenzhen Research Institute of The Hong Kong Polytechnic University, Shenzhen (China)

    2015-07-16

    Highlights: • Simplified sample preparation method for direct analysis of edible oils by MALDI-MS. • Establishment of a preliminary MALDI-MS spectral database of edible oils. • Rapid screening of mixed edible oils and gutter oils. - Abstract: Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils.

  3. Negative Ion In-Source Decay Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for Sequencing Acidic Peptides

    Science.gov (United States)

    McMillen, Chelsea L.; Wright, Patience M.; Cassady, Carolyn J.

    2016-05-01

    Matrix-assisted laser desorption/ionization (MALDI) in-source decay was studied in the negative ion mode on deprotonated peptides to determine its usefulness for obtaining extensive sequence information for acidic peptides. Eight biological acidic peptides, ranging in size from 11 to 33 residues, were studied by negative ion mode ISD (nISD). The matrices 2,5-dihydroxybenzoic acid, 2-aminobenzoic acid, 2-aminobenzamide, 1,5-diaminonaphthalene, 5-amino-1-naphthol, 3-aminoquinoline, and 9-aminoacridine were used with each peptide. Optimal fragmentation was produced with 1,5-diaminonphthalene (DAN), and extensive sequence informative fragmentation was observed for every peptide except hirudin(54-65). Cleavage at the N-Cα bond of the peptide backbone, producing c' and z' ions, was dominant for all peptides. Cleavage of the N-Cα bond N-terminal to proline residues was not observed. The formation of c and z ions is also found in electron transfer dissociation (ETD), electron capture dissociation (ECD), and positive ion mode ISD, which are considered to be radical-driven techniques. Oxidized insulin chain A, which has four highly acidic oxidized cysteine residues, had less extensive fragmentation. This peptide also exhibited the only charged localized fragmentation, with more pronounced product ion formation adjacent to the highly acidic residues. In addition, spectra were obtained by positive ion mode ISD for each protonated peptide; more sequence informative fragmentation was observed via nISD for all peptides. Three of the peptides studied had no product ion formation in ISD, but extensive sequence informative fragmentation was found in their nISD spectra. The results of this study indicate that nISD can be used to readily obtain sequence information for acidic peptides.

  4. Composite glycerol/graphite/aromatic acid matrices for thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry of heterocyclic compounds.

    Science.gov (United States)

    Esparza, Cesar; Borisov, R S; Varlamov, A V; Zaikin, V G

    2016-10-28

    New composite matrices have been suggested for the analysis of mixtures of different synthetic organic compounds (N-containing heterocycles and erectile dysfunction drugs) by thin layer chromatography/matrix-assisted laser desorption ionization time-of-flight mass spectrometry (TLC/MALDI-TOF). Different mixtures of classical MALDI matrices and graphite particles dispersed in glycerol were used for the registration of MALDI mass spectra directly from TLC plates after analytes separation. In most of cases, the mass spectra possessed [M+H](+) ions; however, for some analytes only [M+Na](+) and [M+K](+) ions were observed. These ions have been used to generate visualized TLC chromatograms. The described approach increases the desorption/ionization efficiencies of analytes separated by TLC, prevent spot blurring, simplifies and decrease time for sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Large molecular mass materials in coal derived liquids by {sup 252}Cf-plasma and matrix assisted laser desorption mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Domin, M. [School of Pharmacy, London (United Kingdom). Dept. of Pharmaceutical and Biological Chemistry; Li, S.; Herod, A.A.; Larsen, J.W. [Lehigh Univ., Bethlehem, PA (United States). Dept. of Chemistry; Lazaro, M.J.; Kandiyoti, R. [Imperial College, London (United Kingdom). Dept. of Chemical Engineering and Chemical Technology

    1997-12-31

    A Point of Ayr coal extract, its hydrocracked product and the pyridine solubles/insolubles of a coal tar pitch have been examined using {sup 252}Cf-plasma desorption-mass spectrometry (PDMS) and matrix assisted laser desorption-mass spectrometry (MALDI-MS). Comparison of molecular masses (MMs) between the coal extract and its hydrocracked product by PDMS indicated ranges of masses in the product to be considerably smaller, with number and weight average MMs reduced by approximately a factor of two. MALDI-mass spectra of the same samples indicated a greater reduction in mass. Similar comparison of the pyridine soluble/insoluble fractions of the coal tar pitch showed smaller differences by PD-MS than by MALDI-MS. (orig.)

  6. Size-effects on energy relaxation and excited-species desorption in krypton clusters: Fluorescence lifetime measurements with 10 eV laser excitation

    Science.gov (United States)

    Kanaev, A. V.; Museur, L.; Castex, M. C.

    1997-09-01

    Fluorescence lifetime measurements of KrN clusters (N¯=2-2000) have been carried out using intense 10 eV laser excitation near 3P2 metastable atomic energy level. Two principal groups of electronically excited dimers Kr2* have been found in desorption: dimers, loosely bound near the (3P2+1S0) dissociation limit, ejected from cooled clusters and dimers undergoing vibrational relaxation from hot clusters. The desorption is principally terminated when N¯⩾50 at./cluster. The relaxation kinetics seems to converge to the properties of a solid state for 102⩽N¯⩽103 at./cluster. A variation of the Kr2*(1u/0u-) radiative lifetime, from 264 ns (in gas phase) to 440 ns (N¯=102), has been found. An equilibrium cluster temperature of 57 K has been calculated from this τ(N) dependence.

  7. The role of electron-stimulated desorption in focused electron beam induced deposition

    DEFF Research Database (Denmark)

    van Dorp, Willem F.; Hansen, Thomas Willum; Wagner, Jakob Birkedal;

    2013-01-01

    rate is lower at higher substrate temperatures. From Arrhenius plots we calculated the activation energy for desorption, Edes, of W(CO)6. We found an average value for Edes of 20.3 kJ or 0.21 eV, which is 2.5–3.0 times lower than literature values. This difference between estimates for Edes from FEBIP...

  8. Laser induced white lighting of graphene foam

    Science.gov (United States)

    Strek, Wieslaw; Tomala, Robert; Lukaszewicz, Mikolaj; Cichy, Bartlomiej; Gerasymchuk, Yuriy; Gluchowski, Pawel; Marciniak, Lukasz; Bednarkiewicz, Artur; Hreniak, Dariusz

    2017-01-01

    Laser induced white light emission was observed from porous graphene foam irradiated with a focused continuous wave beam of the infrared laser diode. It was found that the intensity of the emission increases exponentially with increasing laser power density, having a saturation level at ca. 1.5 W and being characterized by stable emission conditions. It was also observed that the white light emission is spatially confined to the focal point dimensions of the illuminating laser light. Several other features of the laser induced white light emission were also discussed. It was observed that the white light emission is highly dependent on the electric field intensity, allowing one to modulate the emission intensity. The electric field intensity ca. 0.5 V/μm was able to decrease the white light intensity by half. Origins of the laser-induced white light emission along with its characteristic features were discussed in terms of avalanche multiphoton ionization, inter-valence charge transfer and possible plasma build-up processes. It is shown that the laser-induced white light emission may be well utilized in new types of white light sources.

  9. Laser induced white lighting of graphene foam

    Science.gov (United States)

    Strek, Wieslaw; Tomala, Robert; Lukaszewicz, Mikolaj; Cichy, Bartlomiej; Gerasymchuk, Yuriy; Gluchowski, Pawel; Marciniak, Lukasz; Bednarkiewicz, Artur; Hreniak, Dariusz

    2017-01-01

    Laser induced white light emission was observed from porous graphene foam irradiated with a focused continuous wave beam of the infrared laser diode. It was found that the intensity of the emission increases exponentially with increasing laser power density, having a saturation level at ca. 1.5 W and being characterized by stable emission conditions. It was also observed that the white light emission is spatially confined to the focal point dimensions of the illuminating laser light. Several other features of the laser induced white light emission were also discussed. It was observed that the white light emission is highly dependent on the electric field intensity, allowing one to modulate the emission intensity. The electric field intensity ca. 0.5 V/μm was able to decrease the white light intensity by half. Origins of the laser-induced white light emission along with its characteristic features were discussed in terms of avalanche multiphoton ionization, inter-valence charge transfer and possible plasma build-up processes. It is shown that the laser-induced white light emission may be well utilized in new types of white light sources. PMID:28112254

  10. Laser-Induced Incandescence: Excitation Intensity

    Science.gov (United States)

    Vander Wal, Randall L.; Jensen, Kirk A.

    1998-03-01

    Assumptions of theoretical laser-induced incandescence (LII) models along with possible effects of high-intensity laser light on soot aggregates and the constituent primary particles are discussed in relation to selection of excitation laser fluence. Ex situ visualization of laser-heated soot by use of transmission electron microscopy reveals significant morphological changes (graphitization) induced by pulsed laser heating. Pulsed laser transmission measurements within a premixed laminar sooting flame suggest that soot vaporization occurs for laser fluences greater than 0.5 J cm 2 at 1064 nm. Radial LII intensity profiles at different axial heights in a laminar ethylene gas jet diffusion flame reveal a wide range of signal levels depending on the laser fluence that is varied over an eight fold range. Results of double-pulse excitation experiments in which a second laser pulse heats in situ the same soot that was heated by a prior laser pulse are detailed. These two-pulse measurements suggest varying degrees of soot structural change for fluences below and above a vaporization threshold of 0.5 J cm 2 at 1064 nm. Normalization of the radial-resolved LII signals based on integrated intensities, however, yields self-similar profiles. The self-similarity suggests robustness of LII for accurate relative measurement of soot volume fraction despite the morphological changes induced in the soot, variations in soot aggregate and primary particle size, and local gas temperature. Comparison of LII intensity profiles with soot volume fractions ( f v ) derived by light extinction validates LII for quantitative determination of f v upon calibration for laser fluences ranging from 0.09 to 0.73 J cm 2 .

  11. Imaging Mass Spectrometry by Matrix-Assisted Laser Desorption/Ionization and Stress-Strain Measurements in Iontophoresis Transepithelial Corneal Collagen Cross-Linking

    Directory of Open Access Journals (Sweden)

    Paolo Vinciguerra

    2014-01-01

    Full Text Available Purpose. To compare biomechanical effect, riboflavin penetration and distribution in transepithelial corneal collagen cross-linking with iontophoresis (I-CXL, with standard cross linking (S-CXL and current transepithelial protocol (TE-CXL. Materials and Methods. The study was divided into two different sections, considering, respectively, rabbit and human cadaver corneas. In both sections corneas were divided according to imbibition protocols and irradiation power. Imaging mass spectrometry by matrix-assisted laser desorption/ionization (MALDI-IMS and stress-strain measurements were used. Forty-eight rabbit and twelve human cadaver corneas were evaluated. Results. MALDI-IMS showed a deep riboflavin penetration throughout the corneal layers with I-CXL, with a roughly lower concentration in the deepest layers when compared to S-CXL, whereas with TE-CXL penetration was considerably less. In rabbits, there was a significant increase (by 71.9% and P=0.05 in corneal rigidity after I-CXL, when compared to controls. In humans, corneal rigidity increase was not significantly different among the subgroups. Conclusions. In rabbits, I-CXL induced a significant increase in corneal stiffness as well as better riboflavin penetration when compared to controls and TE-CXL but not to S-CXL. Stress-strain in human corneas did not show significant differences among techniques, possibly because of the small sample size of groups. In conclusion, I-CXL could be a valid alternative to S-CXL for riboflavin delivery in CXL, preserving the epithelium.

  12. Characterizing changes in snow crab (Chionoecetes opilio) cryptocyanin protein during molting using matrix-assisted laser desorption/ionization mass spectrometry and tandem mass spectrometry.

    Science.gov (United States)

    Demian, Wael L L; Jahouh, Farid M; Stansbury, Don; Randell, Edward; Brown, Robert J; Banoub, Joseph H

    2014-02-28

    We report the matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) characterization of the cryptocyanin proteins of the juvenile Chionoecetes opilio crabs during their molting and non-molting phases. In order to assess the structural cryptocyanin protein differences between the molting and non-molting phases, the obtained peptides were sequenced by MALDI low-energy collision-induced dissociation tandem mass spectrometry (CID-MS/MS). The cryptocyanin protein was isolated by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and analyzed by MALDI-TOF/TOF-MS. The purified cryptocyanin protein was sequenced, using the 'bottom-up' approach. After tryptic digestion, the peptide mixture was analyzed by MALDI-QqTOF-MS/MS and the data obtained were used for the peptide mass fingerprinting (PMF) identification by means of the Mascot database. It was demonstrated using MALDI-TOF/TOF-MS that the actual molecular weights of the non-molting and molting cryptocyanin proteins were different; these were, respectively, 67.6 kDa and 68.1 kDa. Using low-energy CID-MS/MS we have sequenced the trytic peptides to monitor the differences and similarities between the cryptocyanin molecular structures during the molting and non-molting stages. We have demonstrated for the first time that the actual molecular masses of the cryptocyanin protein during the molting and non-molting phases were different. The MALDI-CID-MS/MS analyses allowed the sequencing of the cryptocyanins after tryptic digestion, during the molting and non-molting stages, and showed some similarities and staggering differences between the identified cryptocyanin peptides. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Quantitation of peptides and proteins by matrix-assisted laser desorption/ionization mass spectrometry using (18)O-labeled internal standards

    DEFF Research Database (Denmark)

    Mirgorodskaya, O A; Kozmin, Y P; Titov, M I;

    2000-01-01

    A method for quantitating proteins and peptides in the low picomole and sub-picomole range has been developed using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) with internal (18)O-labeled standards. A simple procedure is proposed to produce such internal standards...... for the tested sample by enzymatic hydrolysis of the same sample (with known concentration) in (18)O-water. A mathematical algorithm was developed which uses the isotopic patterns of the substance, the internal standard, and the substance/internal standard mixture for accurate quantitation of the substance...

  14. Semiconductor Nanomaterials-Based Fluorescence Spectroscopic and Matrix-Assisted Laser Desorption/Ionization (MALDI Mass Spectrometric Approaches to Proteome Analysis

    Directory of Open Access Journals (Sweden)

    Suresh Kumar Kailasa

    2013-12-01

    Full Text Available Semiconductor quantum dots (QDs or nanoparticles (NPs exhibit very unusual physico-chemcial and optical properties. This review article introduces the applications of semiconductor nanomaterials (NMs in fluorescence spectroscopy and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS for biomolecule analysis. Due to their unique physico-chemical and optical properties, semiconductors NMs have created many new platforms for investigating biomolecular structures and information in modern biology. These semiconductor NMs served as effective fluorescent probes for sensing proteins and cells and acted as affinity or concentrating probes for enriching peptides, proteins and bacteria proteins prior to MALDI-MS analysis.

  15. In situ probing of cholesterol in astrocytes at the single-cell level using laser desorption ionization mass spectrometric imaging with colloidal silver.

    Science.gov (United States)

    Perdian, D C; Cha, Sangwon; Oh, Jisun; Sakaguchi, Donald S; Yeung, Edward S; Lee, Young Jin

    2010-04-30

    Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level.

  16. Discovery of rifampicin as a new anti-glycating compound by matrix-assisted laser desorption/ionization mass spectrometry-based insulin glycation assay.

    Science.gov (United States)

    Golegaonkar, Sandeep B; Bhonsle, Hermangi S; Boppana, Ramanamurthy; Kulkarni, Mahesh J

    2010-01-01

    An in vitro insulin glycation assay was developed for screening glycation inhibitors. The assay involves the use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for monitoring the formation of glycated insulin. The assay is simple, rapid and amenable for high throughput screening. Using this assay we have discovered a strong anti-glycation activity for the anti-tuberculosis drug rifampicin. These results were compared with bovine serum albumin glucose fluorescence assay. In addition, the IC(50) of rifampicin was lower than that of aminoguanidine, a known anti-glycating agent, suggesting that rifampicin is a more potent glycation inhibitor.

  17. Evaluation of matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF) mass spectrometry for identification of Candida parapsilosis, C. orthopsilosis and C. metapsilosis.

    Science.gov (United States)

    Quiles-Melero, I; García-Rodríguez, J; Gómez-López, A; Mingorance, J

    2012-01-01

    We have evaluated matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF) mass spectrometry for the rapid identification of Candida parapsilosis, C. orthopsilosis and C. metapsilosis. A total of 103 isolates, including reference strains and clinical isolates, were identified by pyrosequencing of the ITS1 region and then assay by MALDI-TOF mass spectrometry. Concordance between the two methods was 100%, showing that MALDI-TOF may be useful as a rapid and reliable method for discrimination of species within the C. parapsilosis group.

  18. A novel type of matrix for surface-assisted laser desorption-ionization mass spectrometric detection of biomolecules using metal-organic frameworks.

    Science.gov (United States)

    Fu, Chien-Ping; Lirio, Stephen; Liu, Wan-Ling; Lin, Chia-Her; Huang, Hsi-Ya

    2015-08-12

    A 3D metal-organic framework (MOF) nanomaterial as matrix for surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) and tandem mass spectrometry (MS/MS) was developed for the analysis of complex biomolecules. Unlike other nanoparticle matrices, this MOF nanomaterial does not need chemical modification prior to use. An exceptional signal reproducibility as well as very low background interferences in analyzing mono-/di-saccharides, peptides and complex starch digests demonstrate its high potential for biomolecule assays, especially for small molecules.

  19. Structure Determination of β-Glucans from Ganoderma lucidum with Matrix-assisted Laser Desorption/ionization (MALDI Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wen-Bin Yang

    2008-08-01

    Full Text Available A novel method that uses matrix-assisted laser desorption/ionization (MALDI mass spectrometry to analyze molecular weight and sequencing of glucan in Ganoderma lucidum is presented. Thus, β-glucan, which was isolated from fruiting bodies of G. lucidum, was measured in a direct and fast way using MALDI mass spectrometry. In addition, tandem mass spectrometry of permethylated glucans of G. lucidum, dextran, curdlan and maltohexaose were also pursued and different fragment patterns were obtained. The G. lucidum glucan structure was determined and this method for linkage analysis of permethylated glucan has been proven feasible.

  20. Assessment of Reproducibility of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Bacterial and Yeast Identification.

    Science.gov (United States)

    Westblade, Lars F; Garner, Omai B; MacDonald, Karen; Bradford, Constance; Pincus, David H; Mochon, A Brian; Jennemann, Rebecca; Manji, Ryhana; Bythrow, Maureen; Lewinski, Michael A; Burnham, Carey-Ann D; Ginocchio, Christine C

    2015-07-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has revolutionized the identification of clinical bacterial and yeast isolates. However, data describing the reproducibility of MALDI-TOF MS for microbial identification are scarce. In this study, we show that MALDI-TOF MS-based microbial identification is highly reproducible and can tolerate numerous variables, including differences in testing environments, instruments, operators, reagent lots, and sample positioning patterns. Finally, we reveal that samples of bacterial and yeast isolates prepared for MALDI-TOF MS identification can be repeatedly analyzed without compromising organism identification.

  1. Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of KPC-Producing Klebsiella pneumoniae.

    Science.gov (United States)

    Gaibani, Paolo; Galea, Anna; Fagioni, Marco; Ambretti, Simone; Sambri, Vittorio; Landini, Maria Paola

    2016-10-01

    We evaluated a real-time single-peak (11.109-Da) detection assay based on matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for the identification of Klebsiella pneumoniae carbapenemase (KPC)-producing K. pneumoniae Our results demonstrated that the 11.109-Da peak was detected in 88.2% of the KPC producers. Analysis of blaKPC-producing K. pneumoniae showed that the gene encoding the 11.109-Da protein was commonly (97.8%) associated with the Tn4401a isoform.

  2. Evaluation of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of KPC-Producing Klebsiella pneumoniae

    Science.gov (United States)

    Galea, Anna; Fagioni, Marco; Ambretti, Simone; Sambri, Vittorio; Landini, Maria Paola

    2016-01-01

    We evaluated a real-time single-peak (11.109-Da) detection assay based on matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) for the identification of Klebsiella pneumoniae carbapenemase (KPC)-producing K. pneumoniae. Our results demonstrated that the 11.109-Da peak was detected in 88.2% of the KPC producers. Analysis of blaKPC-producing K. pneumoniae showed that the gene encoding the 11.109-Da protein was commonly (97.8%) associated with the Tn4401a isoform. PMID:27413192

  3. Natural products in Glycyrrhiza glabra (licorice) rhizome imaged at the cellular level by atmospheric pressure matrix-assisted laser desorption/ionization tandem mass spectrometry imaging

    DEFF Research Database (Denmark)

    Li, Bin; Bhandari, Dhaka Ram; Janfelt, Christian

    2014-01-01

    The rhizome of Glycyrrhiza glabra (licorice) was analyzed by high-resolution mass spectrometry imaging and tandem mass spectrometry imaging. An atmospheric pressure matrix-assisted laser desorption/ionization imaging ion source was combined with an orbital trapping mass spectrometer in order...... to obtain high-resolution imaging in mass and space. Sections of the rhizome were imaged with a spatial resolution of 10 μm in the positive ion mode, and a large number of secondary metabolites were localized and identified based on their accurate mass and MS/MS fragmentation patterns. Major tissue...

  4. Metal surface nitriding by laser induced plasma

    Science.gov (United States)

    Thomann, A. L.; Boulmer-Leborgne, C.; Andreazza-Vignolle, C.; Andreazza, P.; Hermann, J.; Blondiaux, G.

    1996-10-01

    We study a nitriding technique of metals by means of laser induced plasma. The synthesized layers are composed of a nitrogen concentration gradient over several μm depth, and are expected to be useful for tribological applications with no adhesion problem. The nitriding method is tested on the synthesis of titanium nitride which is a well-known compound, obtained at present by many deposition and diffusion techniques. In the method of interest, a laser beam is focused on a titanium target in a nitrogen atmosphere, leading to the creation of a plasma over the metal surface. In order to understand the layer formation, it is necessary to characterize the plasma as well as the surface that it has been in contact with. Progressive nitrogen incorporation in the titanium lattice and TiN synthesis are studied by characterizing samples prepared with increasing laser shot number (100-4000). The role of the laser wavelength is also inspected by comparing layers obtained with two kinds of pulsed lasers: a transversal-excited-atmospheric-pressure-CO2 laser (λ=10.6 μm) and a XeCl excimer laser (λ=308 nm). Simulations of the target temperature rise under laser irradiation are performed, which evidence differences in the initial laser/material interaction (material heated thickness, heating time duration, etc.) depending on the laser features (wavelength and pulse time duration). Results from plasma characterization also point out that the plasma composition and propagation mode depend on the laser wavelength. Correlation of these results with those obtained from layer analyses shows at first the important role played by the plasma in the nitrogen incorporation. Its presence is necessary and allows N2 dissociation and a better energy coupling with the target. Second, it appears that the nitrogen diffusion governs the nitriding process. The study of the metal nitriding efficiency, depending on the laser used, allows us to explain the differences observed in the layer features

  5. Heat pump processes induced by laser radiation

    Science.gov (United States)

    Garbuny, M.; Henningsen, T.

    1980-01-01

    A carbon dioxide laser system was constructed for the demonstration of heat pump processes induced by laser radiation. The system consisted of a frequency doubling stage, a gas reaction cell with its vacuum and high purity gas supply system, and provisions to measure the temperature changes by pressure, or alternatively, by density changes. The theoretical considerations for the choice of designs and components are dicussed.

  6. The adsorption-desorption transition of double-stranded DNA interacting with an oppositely charged dendrimer induced by multivalent anions.

    Science.gov (United States)

    Jiang, Yangwei; Zhang, Dong; Zhang, Yaoyang; Deng, Zhenyu; Zhang, Linxi

    2014-05-28

    The adsorption-desorption transition of DNA in DNA-dendrimer solutions is observed when high-valence anions, such as hexavalent anions, are added to the DNA-dendrimer solutions. In the DNA-dendrimer solutions with low-valence anions, dendrimers bind tightly with the V-shaped double-stranded DNA. When high-valence anions, such as pentavalent or hexavalent anions, are added to the DNA-dendrimer solutions, the double-stranded DNA chains can be stretched straightly and the dendrimers are released from the double-stranded DNA chains. In fact, adding high-valence anions to the solutions can change the charge spatial distribution in the DNA-dendrimer solutions, and weaken the electrostatic interactions between the positively charged dendrimers and the oppositely charged DNA chains. Adsorption-desorption transition of DNA is induced by the overcharging of dendrimers. This investigation is capable of helping us understand how to control effectively the release of DNA in gene/drug delivery because an effective gene delivery for dendrimers includes non-covalent DNA-dendrimer binding and the effective release of DNA in gene therapy.

  7. Treatment of Laser Induced Retinal Injuries.

    Science.gov (United States)

    1986-04-02

    END 1.0 1.18 Yl(-ROCOPY Ri yjTuION If ’,! (HART !. UIH; iLruud @ N TREATMENT OF LASER INDUCED RETINAL INJURIES (ANNUAL REPORT 00 DTIC Michael Belkin...NO. CCESSION NO _______________________________61102A I102BS1O0 CF 1i. 446 TITLE (Indude S*.curny Claifkaion) TREATMENT OF LASER INDUCED RETINAL... INJURIES PERSONAL AUTHOR(S) M. BELKIN N. NAVEH a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Mont. D y) S. PAGE COUNT FROM Xaj& TO l 2Ann

  8. Analysis of Antiretrovirals in Single Hair Strands for Evaluation of Drug Adherence with Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging.

    Science.gov (United States)

    Rosen, Elias P; Thompson, Corbin G; Bokhart, Mark T; Prince, Heather M A; Sykes, Craig; Muddiman, David C; Kashuba, Angela D M

    2016-01-19

    Adherence to a drug regimen can be a strong predictor of health outcomes, and validated measures of adherence are necessary at all stages of therapy from drug development to prescription. Many of the existing metrics of drug adherence (e.g., self-report, pill counts, blood monitoring) have limitations, and analysis of hair strands has recently emerged as an objective alternative. Traditional methods of hair analysis based on LC-MS/MS (segmenting strands at ≥1 cm length) are not capable of preserving a temporal record of drug intake at higher resolution than approximately 1 month. Here, we evaluated the detectability of HIV antiretrovirals (ARVs) in hair from a range of drug classes using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging (MSI) with 100 μm resolution. Infrared laser desorption of hair strands was shown to penetrate into the strand cortex, allowing direct measurement by MSI without analyte extraction. Using optimized desorption conditions, a linear correlation between IR-MALDESI ion abundance and LC-MS/MS response was observed for six common ARVs with estimated limits of detection less than or equal to 1.6 ng/mg hair. The distribution of efavirenz (EFV) was then monitored in a series of hair strands collected from HIV infected, virologically suppressed patients. Because of the role hair melanin plays in accumulation of basic drugs (like most ARVs), an MSI method to quantify the melanin biomarker pyrrole-2,3,5-tricarboxylic acid (PTCA) was evaluated as a means of normalizing drug response between patients to develop broadly applicable adherence criteria.

  9. Direct Imaging Mass Spectrometry of Plant Leaves Using Surface-assisted Laser Desorption/Ionization with Sputter-deposited Platinum Film.

    Science.gov (United States)

    Ozawa, Tomoyuki; Osaka, Issey; Hamada, Satoshi; Murakami, Tatsuya; Miyazato, Akio; Kawasaki, Hideya; Arakawa, Ryuichi

    2016-01-01

    Plant leaves administered with systemic insecticides as agricultural chemicals were analyzed using imaging mass spectrometry (IMS). Matrix-assisted laser desorption/ionization (MALDI) is inadequate for the detection of insecticides on leaves because of the charge-up effect that occurs on the non-conductive surface of the leaves. In this study, surface-assisted laser desorption/ionization with a sputter-deposited platinum film (Pt-SALDI) was used for direct analysis of chemicals in plant leaves. Sputter-deposited platinum (Pt) films were prepared on leaves administered with the insecticides. A sputter-deposited Pt film with porous structure was used as the matrix for Pt-SALDI. Acephate and acetamiprid contained in the insecticides on the leaves could be detected using Pt-SALDI-MS, but these chemical components could not be adequately detected using MALDI-MS because of the charge-up effect. Enhancement of ion yields for the insecticides was achieved using Pt-SALDI, accompanied by prevention of the charge-up effect by the conductive Pt film. The movement of systemic insecticides in plants could be observed clearly using Pt-SALDI-IMS. The distribution and movement of components of systemic insecticides on leaves could be analyzed directly using Pt-SALDI-IMS. Additionally, changes in the properties of the chemicals with time, as an indicator of the permeability of the insecticides, could be evaluated.

  10. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) coupled to XAD fractionation: Method to algal organic matter characterization.

    Science.gov (United States)

    Nicolau, Rudy; Leloup, Maud; Lachassagne, Delphine; Pinault, Emilie; Feuillade-Cathalifaud, Geneviève

    2015-05-01

    This work is focused on the development of an analytical procedure for the improvement of the Organic Matter structure characterization, particularly the algal matter. Two fractions of algal organic matter from laboratory cultures of algae (Euglena gracilis) and cyanobacteria (Microcystis aeruginosa) were extracted with XAD resins. The fractions were studied using laser desorption ionization (LDI) and Matrix-Assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF). A comparison with the natural organic matter characteristics from commercial humic acids and fulvic acids extracted from Suwannee River was performed. Results show that algal and natural organic matters have unique quasi-polymeric structures. Significant repeating patterns were identified. Different fractions extracted from organic matter with common origin had common structures. Thus, 44, 114 and 169Da peaks separation for fractions from E. gracilis organic matter and 28, 58 and 100Da for M. aeruginosa ones were clearly observed. Using the developed protocol, a structural scheme and organic matter composition were obtained. The range 600-2000Da contained more architectural composition differences than the range 100-600Da, suggesting that organic matter is composed of an assembly of common small molecules. Associated to specific monomers, particular patterns were common to all samples but assembly and resulting structure were unique for each organic matter. Thus, XAD fractionation coupled to mass spectroscopy allowed determining a specific fingerprint for each organic matter.

  11. UV photoprocessing of CO2 ice: a complete quantification of photochemistry and photon-induced desorption processes

    CERN Document Server

    Martín-Doménech, R; Caro, G M Muñoz; Cruz-Díaz, G A; Chen, Y -J; Herrero, V J; Tanarro, I

    2015-01-01

    Ice mantles that formed on top of dust grains are photoprocessed by the secondary ultraviolet (UV) field in cold and dense molecular clouds. UV photons induce photochemistry and desorption of ice molecules. Experimental simulations dedicated to ice analogs under astrophysically relevant conditions are needed to understand these processes. We present UV-irradiation experiments of a pure CO2 ice analog. Calibration of the QMS allowed us to quantify the photodesorption of molecules to the gas phase. This information was added to the data provided by the FTIR on the solid phase to obtain a complete quantitative study of the UV photoprocessing of an ice analog. Experimental simulations were performed in an ultra-high vacuum chamber. Ice samples were deposited onto an infrared transparent window at 8K and were subsequently irradiated with a microwave-discharged hydrogen flow lamp. After irradiation, ice samples were warmed up until complete sublimation was attained. Photolysis of CO2 molecules initiates a network o...

  12. UV Laser-Induced DNA Photochemistry

    Science.gov (United States)

    1991-05-13

    nicking of DNA) can be described by a Poisson distribution (Armitage, 1971; Kroeber and LaForge, 1980). Such a distribution can be used to determine...specificity of the alkali-sensitive lesions induced in DNA by high intensity ultraviolet laser radiation", Photochem. Photohiol. 52:509-517 Kroeber , D.W

  13. Laser-Induced Fluorescence in Gaseous [I[subscript]2] Excited with a Green Laser Pointer

    Science.gov (United States)

    Tellinghuisen, Joel

    2007-01-01

    A green laser pointer could be used in a flashy demonstration of laser-induced fluorescence in the gas phase by directing the beam of the laser through a cell containing [I[subscript]2] at its room temperature vapor pressure. The experiment could be used to provide valuable insight into the requirements for laser-induced fluorescence (LIF) and the…

  14. Laser-induced axion photoproduction

    Science.gov (United States)

    Brodsky, S. J.; Mottola, E.; Muzinich, I. J.; Soldate, M.

    1986-01-01

    Axion photoproduction is suggested as a systematic technique for investigating the coupling of new elementary pseudoscalar or scalar particles in the megaelectronvolt mass range to leptons, photons, and hadronic matter. The experiments involve a configuration where a low-energy photon collides with a relativistic electron beam. Threshold production energies of 300 GeV can be accomplished with an optical laser, and those of 14.5-50 GeV can be achieved with wigglers directed onto an electron beam. With this scheme, at least 10 to the -7th of the electrons can be converted to axions, providing a 1-100 thousand/s relativistic beam of axions.

  15. Laser-induced lipolysis on adipose cells

    Science.gov (United States)

    Solarte, Efrain; Gutierrez, O.; Neira, Rodrigo; Arroyave, J.; Isaza, Carolina; Ramirez, Hugo; Rebolledo, Aldo F.; Criollo, Willian; Ortiz, C.

    2004-10-01

    Recently, a new liposuction technique, using a low-level laser (LLL) device and Ultrawet solution prior to the procedure, demonstrated the movement of fat from the inside to the outside of the adipocyte (Neira et al., 2002). To determine the mechanisms involved, we have performed Scanning and Transmission Electron Microscopy studies; Light transmittance measurements on adipocyte dilutions; and a study of laser light propagation in adipose tissue. This studies show: 1. Cellular membrane alterations. 2. LLL is capable to reach the deep adipose tissue layer, and 3. The tumescence solution enhances the light propagation by clearing the tissue. MRI studies demonstrated the appearance of fat on laser treated abdominal tissue. Besides, adipocytes were cultivated and irradiated to observe the effects on isolated cells. These last studies show: 1. 635 nm-laser alone is capable of mobilizing cholesterol from the cell membrane; this action is enhanced by the presence of adrenaline and lidocaine. 2. Intracellular fat is released from adipocytes by co joint action of adrenaline, aminophyline and 635 nm-laser. Results are consistent with a laser induced cellular process, which causes fat release from the adipocytes into the intercellular space, besides the modification of the cellular membranes.

  16. Laser induced ponderomotive convection in water

    CERN Document Server

    Shneider, M N

    2015-01-01

    A new mechanism for inducing convection during IR laser interaction with water or any absorbing polar liquid is described theoretically. The numerical simulations performed using the developed model show that the ponderomotive force produces water flow in the direction of the laser beam propagation. In the later stage of interaction, when water temperature rises, the Archimedes force becomes first comparable and then dominant producing convection directed against the vector of gravitational acceleration (upward). The theoretical estimates and the numerical simulations predict fluid dynamics that is similar to the observed in the previous experiments.

  17. Laser induced forward transfer of soft materials

    Science.gov (United States)

    Palla-Papavlu, A.; Dinca, V.; Luculescu, C.; Shaw-Stewart, J.; Nagel, M.; Lippert, T.; Dinescu, M.

    2010-12-01

    A strong research effort is presently aimed at patterning methodologies for obtaining controlled defined micrometric polymeric structures for a wide range of applications, including electronics, optoelectronics, sensors, medicine etc. Lasers have been identified as appropriate tools for processing of different materials, such as ceramics and metals, but also for soft, easily damageable materials (biological compounds and polymers). In this work we study the dynamics of laser induced forward transfer (LIFT) with a gap between the donor and the receiver substrates, which is the basis for possible applications that require multilayer depositions with high spatial resolution.

  18. Laser induced fluorescence technique for environmental applications

    Science.gov (United States)

    Utkin, Andrei B.; Felizardo, Rui; Gameiro, Carla; Matos, Ana R.; Cartaxana, Paulo

    2014-08-01

    We discuss the development of laser induced fluorescence sensors and their application in the evaluation of water pollution and physiological status of higher plants and algae. The sensors were built on the basis of reliable and robust solid-state Nd:YAG lasers. They demonstrated good efficiency in: i) detecting and characterizing oil spills and dissolved organic matter; ii) evaluating the impact of stress on higher plants (cork oak, maritime pine, and genetically modified Arabidopsis); iii) tracking biomass changes in intertidal microphytobenthos; and iv) mapping macroalgal communities in the Tagus Estuary.

  19. Identification of Laser-induced Lamb waves

    Energy Technology Data Exchange (ETDEWEB)

    Castro C, M.; Lopez, J.A. [Physics Department, U. 1: El Paso, El Paso, TX 79968 (United States); Osegueda, R. [FAST Center, Burgess Hall, U. 1: El Paso, El Paso, TX 79968 (United States)

    2007-07-01

    We studied experimentally the ultrasonic propagating modes produced by a laser pulse of 532 nm while impinging on an aluminum plate. The beam, shaped as a line, induced various Lamb modes whose relative power varied with the laser line length. Identification of their mode was performed by detecting the ultrasonic modes with piezoelectric detectors along a propagation direction orthogonal to the line, and using two dimensional fast Fourier transform. Good agreement is observed between theoretical and experimental dispersion curves for the first fundamental symmetric and anti-symmetric modes. Results are shown for 12 and 24 mm laser line-length at 13.6 and 16.8 ns pulse-width. (Author)

  20. On-Tissue Derivatization via Electrospray Deposition for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging of Endogenous Fatty Acids in Rat Brain Tissues.

    Science.gov (United States)

    Wu, Qian; Comi, Troy J; Li, Bin; Rubakhin, Stanislav S; Sweedler, Jonathan V

    2016-06-07

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is used for the multiplex detection and characterization of diverse analytes over a wide mass range directly from tissues. However, analyte coverage with MALDI MSI is typically limited to the more abundant compounds, which have m/z values that are distinct from MALDI matrix-related ions. On-tissue analyte derivatization addresses these issues by selectively tagging functional groups specific to a class of analytes, while simultaneously changing their molecular masses and improving their desorption and ionization efficiency. We evaluated electrospray deposition of liquid-phase derivatization agents as a means of on-tissue analyte derivatization using 2-picolylamine; we were able to detect a range of endogenous fatty acids with MALDI MSI. When compared with airbrush application, electrospray led to a 3-fold improvement in detection limits and decreased analyte delocalization. Six fatty acids were detected and visualized from rat cerebrum tissue using a MALDI MSI instrument operating in positive mode. MALDI MSI of the hippocampal area allowed targeted fatty acid analysis of the dentate gyrus granule cell layer and the CA1 pyramidal layer with a 20-μm pixel width, without degrading the localization of other lipids during liquid-phase analyte derivatization.

  1. A DFT analysis of the adsorption of nitrogen oxides on Fe-doped graphene, and the electric field induced desorption

    Science.gov (United States)

    Cortés-Arriagada, Diego; Villegas-Escobar, Nery

    2017-10-01

    Density functional theory calculations were carried out to study the adsorption and sensing properties of Fe-doped graphene nanosheets (FeG) toward nitrogen oxides (NO, NO2, and N2O). The results indicated the adsorption of nitrogen oxides is significantly increased onto FeG compared to pristine graphene, reaching adsorption energies of 1.1-2.2 eV, even with a high stability at room temperature. As a result of the larger charge transfer and strong chemical binding, the bandgap of the adsorbent-adsorbate systems is increased in up to 0.5 eV with respect to the free FeG, indicating that FeG is highly sensitive to nitrogen oxides. It was also evidenced the adsorption and sensing properties remain even in the presence of O2 currents for N2O, where a co-adsorption mechanism was analyzed. Besides, NO2 is capable to induce the largest magnetization of FeG. Finally, positive electric fields of at least 0.04 a.u. decrease the stability of the adsorbent-adsorbate interactions, inducing the desorption process. Therefore, FeG emerges as a promising low-dimensional material with excellent adsorption and sensing properties to be applied in solid state sensors of nitrogen oxides, where electric fields can be used as a strategy for the FeG reactivation in repetitive sensing applications.

  2. Investigation of tissue inhibitor of metalloproteinases 1 in plasma from colorectal cancer patients and blood donors by surface-enhanced laser desorption/ionization time-of-flight mass spectrometryscopy

    DEFF Research Database (Denmark)

    CASPERSEN, M. B.; Sørensen, N. M.; Iversen, P

    2007-01-01

    in plasma, surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI TOF MS) was used. TIMP-1 measurements of plasma from 16 healthy donors and 14 CRC patients were performed using TIMP-1 monoclonal antibody in SELDI TOF MS and ELISA. SELDI TOF MS applying an antibody to TIMP-1...

  3. Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Analysis of Gram-Positive, Catalase-Negative Cocci Not Belonging to the Streptococcus or Enterococcus Genus and Benefits of Database Extension

    DEFF Research Database (Denmark)

    Christensen, Jens Jørgen; Dargis, Rimtas; Hammer, Monja;

    2012-01-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry with a Bruker Daltonics microflex LT system was applied to 90 well-characterized catalase-negative, Gram-positive cocci not belonging to the streptococci or enterococci. Biotyper version 2.0.43.1 software was...

  4. Classification of wheat varieties: Use of two-dimensional gel electrophoresis for varieties that can not be classified by matrix assisted laser desorption/ionization-time of flight-mass spectrometry and an artificial neural network

    DEFF Research Database (Denmark)

    Jacobsen, Susanne; Nesic, Ljiljana; Petersen, Marianne Kjerstine;

    2001-01-01

    Analyzing a gliadin extract by matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI- TOF-MS) combined with an artificial neural network (ANN) is a suitable method for identification of wheat varieties. However, the ANN can not distinguish between all different wheat...

  5. Localization of an O-glycosylated site in the recombinant barley alpha-amylase 1 produced in yeast and correction of the amino acid sequence using matrix-assisted laser desorption/ionization mass spectrometry of peptide mixtures

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Søgaard, M; Svensson, B

    1994-01-01

    Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of peptide mixtures was used to characterize recombinant barley alpha-amylase 1, produced in yeast. Three peptide mixtures were generated by cleavage with CNBr, digestion with endoproteinase Lys-C and Asp-N, respectively, an...

  6. Bacteriophage cell lysis of Shiga toxin-producing Escherichia coli for top-down proteomic identification of Shiga toxin 1 & 2 using matrix-assisted laser desorption/ionization tandem time-of-light mass spectrometry

    Science.gov (United States)

    RATIONALE: Analysis of bacteria by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) often relies upon sample preparation methods that result in cell lysis, e.g. bead-beating. However, Shiga toxin-producing Escherichia coli (STEC) can undergo bacteriophage...

  7. Pulsed laser positive ion desorption from a model hydrated inorganic crystal (CaHPO 4·2H 2O) at 248 nm

    Science.gov (United States)

    Dawes, M. L.; Langford, S. C.; Dickinson, J. T.

    1998-05-01

    We examine the laser-induced positive ion emission of a typical, wide band gap, hydrated inorganic single crystal, CaHPO 4·2H 2O (brushite), at 248 nm (KrF excimer) in vacuum. As-grown brushite is quite resistant to laser damage and yields little ion emission at fluences below 1 J/cm 2. In the presence of surface damage by abrasion or heating-induced transformations, intense laser-induced ion emission appears at lower fluences. The ion energy and fluence dependence are consistent with a defect mediated, multiple photon emission mechanism. In particular, the transport of hydrated Ca + to the surface, followed by adsorption at anion defects (and removal of water by evaporation), can provide an ideal environment for ion emission. The implications with regard to the UV laser ablation of hydrated environmental and biological minerals are discussed.

  8. DNA deposition through laser induced forward transfer.

    Science.gov (United States)

    Colina, M; Serra, P; Fernández-Pradas, J M; Sevilla, L; Morenza, J L

    2005-02-15

    Laser induced forward transfer (LIFT) is a laser direct write technique that appears to be specially adequate for the production of biosensors, since it permits to deposit patterns of biomolecules with high spatial resolution. In the LIFT technique, a laser pulse is focused on a thin film of the material to be transferred through a transparent support, and under the action of the laser pulse, a small fraction of the film is transferred to a receptor substrate that is placed parallel to the film-support system. In the case of biomolecules transfer, the thin film consists in a liquid solution containing the biomolecules. In this work, microarrays of two different cDNAs have been both spotted by LIFT and pin microspotting onto a poly-L-lysine treated glass slide. Once transferred, all the microarrays have been submitted to hybridization with the complementary strands of the spotted cDNAs, each one tagged with a different fluorochrome. Comparative fluorescence scanner analyses have revealed that the microarrays transferred through LIFT are equivalent to those transferred through pin microspotting in terms of signal intensity and gene discrimination capacity, and that the action of the laser pulse does not result in significant damage of the transferred DNA.

  9. In situ liquid-liquid extraction as a sample preparation method for matrix-assisted laser desorption/ionization MS analysis of polypeptide mixtures

    DEFF Research Database (Denmark)

    Kjellström, Sven; Jensen, Ole Nørregaard

    2003-01-01

    A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic...... matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing...... phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research....

  10. Preparation of porous styrenics-based monolithic layers for thin layer chromatography coupled with matrix-assisted laser-desorption/ionization time-of-flight mass spectrometric detection.

    Science.gov (United States)

    Lv, Yongqin; Lin, Zhixing; Tan, Tianwei; Svec, Frantisek

    2013-11-01

    Monolithic 50 μm thin poly(4-methylstyrene-co-chloromethylstyrene-co-divinylbenzene) layers attached to 6.0 cm × 3.3 cm glass plates have been prepared, using a thermally initiated polymerization process. These layers had a well-defined porous structure with a globular morphology demonstrated with SEM images and exhibited superhydrophobic properties characterized with a water contact angle of 157°. They were then used for thin-layer chromatography of peptides and proteins fluorescently labeled with fluorescamine. The spots of individual separated compounds were visualized using UV light, and their identities were confirmed with a matrix-assisted laser desorption/ionization time of flight mass spectrometry. The presence of chloromethylstyrene units in the polymer enabled hypercrosslinking via a Friedel-Crafts alkylation reaction, and led to monoliths with much larger surface areas, which were suitable for separations of small dye molecules.

  11. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2003-2004.

    Science.gov (United States)

    Harvey, David J

    2009-01-01

    This review is the third update of the original review, published in 1999, on the application of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings the topic to the end of 2004. Both fundamental studies and applications are covered. The main topics include methodological developments, matrices, fragmentation of carbohydrates and applications to large polymeric carbohydrates from plants, glycans from glycoproteins and those from various glycolipids. Other topics include the use of MALDI MS to study enzymes related to carbohydrate biosynthesis and degradation, its use in industrial processes, particularly biopharmaceuticals and its use to monitor products of chemical synthesis where glycodendrimers and carbohydrate-protein complexes are highlighted.

  12. Feasibility of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) networking in university hospitals in Brussels.

    Science.gov (United States)

    Martiny, D; Cremagnani, P; Gaillard, A; Miendje Deyi, V Y; Mascart, G; Ebraert, A; Attalibi, S; Dediste, A; Vandenberg, O

    2014-05-01

    The mutualisation of analytical platforms might be used to address rising healthcare costs. Our study aimed to evaluate the feasibility of networking a unique matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) system for common use in several university hospitals in Brussels, Belgium. During a one-month period, 1,055 successive bacterial isolates from the Brugmann University Hospital were identified on-site using conventional techniques; these same isolates were also identified using a MALDI-TOF MS system at the Porte de Hal Laboratory by sending target plates and identification projects via transportation and the INFECTIO_MALDI software (Infopartner, Nancy, France), respectively. The occurrence of transmission problems (helpdesk to manage potential connectivity problems.

  13. Ionic matrices pre-spotted matrix-assisted laser desorption/ionization plates for patient maker following in course of treatment, drug titration, and MALDI mass spectrometry imaging.

    Science.gov (United States)

    Bonnel, David; Franck, Julien; Mériaux, Céline; Salzet, Michel; Fournier, Isabelle

    2013-03-01

    In the current study, we compared plastic matrix-assisted laser desorption/ionization (MALDI) plates pre-spotted with different solid ionic matrices. Data reflect that after 3 months of storage, the standards were oxidized in α-cyano-4-hydroxycinnamic acid (HCCA) whether or not in HCCA/3-acetylpyridine (3APY) and HCCA/aniline, and certain peptides, such as ubiquitin, were not detected using the HCCA matrix, whereas they were detected in pre-spotted ionic matrices. Application in peptidomics of these MALDI matrices pre-spotted plates (after 3 months of storage) with ovarian cyst fluid showed less intense signals with HCCA than with solid ionic matrices. We show that these pre-spotted ionic matrices plates can be used for relative drug quantification, high mass protein detection, and MALDI mass spectrometry imaging.

  14. Stationary phase thickness determines the quality of thin-layer chromatography/matrix-assisted laser desorption and ionization mass spectra of lipids.

    Science.gov (United States)

    Griesinger, Hans; Fuchs, Beate; Süß, Rosmarie; Matheis, Katerina; Schulz, Michael; Schiller, Jürgen

    2014-04-15

    Normal phase thin-layer chromatography (NP TLC) is an established method of (phospho)lipid analysis. The determination of the fatty acyl composition is, however, a more challenging task by NP TLC. The direct coupling of TLC separation with mass spectrometric detection (e.g., matrix-assisted laser desorption/ionization mass spectrometry, MALDI MS), however, enables a detailed characterization of complex lipid mixtures. Here we show that the thickness of the silica gel layer has a considerable effect on the quality of the mass spectra recorded directly from the TLC plate. In particular, the intensity of the matrix background signals can be reduced if "thinner" TLC layers are used. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Evaluation of laser desorption mass spectrometry and UV accelerated aging of dyes on paper as tools for the evaluation of a questioned document.

    Science.gov (United States)

    Grim, Donzna M; Siegel, Jay; Allison, John

    2002-11-01

    Laser desorption mass spectrometry (LDMS) may be used for the detection and identification of dyes found in inks. Naturally-aged and artificially-aged blue and black ballpoint pen inks containing the cationic dye methyl violet were analyzed on paper. The average molecular weight of the dye sample was calculated from LD mass spectral data and plotted versus time. The resulting aging curves demonstrate that, as dye degradation increases, the average molecular weight of the dye decreases. Typical variables involved in ink aging, such as the type of paper and ink formulation, were investigated. Results show that these variables influence the rate of dye degradation. Furthermore, UV accelerated aging has been developed and tested as an alternative to thermal approaches.

  16. Microbial typing by matrix-assisted laser desorption ionization-time of flight mass spectrometry: do we need guidance for data interpretation?

    Science.gov (United States)

    Spinali, Sébastien; van Belkum, Alex; Goering, Richard V; Girard, Victoria; Welker, Martin; Van Nuenen, Marc; Pincus, David H; Arsac, Maud; Durand, Géraldine

    2015-03-01

    The integration of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) in clinical microbiology has revolutionized species identification of bacteria, yeasts, and molds. However, beyond straightforward identification, the method has also been suggested to have the potential for subspecies-level or even type-level epidemiological analyses. This minireview explores MALDI-TOF MS-based typing, which has already been performed on many clinically relevant species. We discuss the limits of the method's resolution and we suggest interpretative criteria allowing valid comparison of strain-specific data. We conclude that guidelines for MALDI-TOF MS-based typing can be developed along the same lines as those used for the interpretation of data from pulsed-field gel electrophoresis (PFGE).

  17. Inkjet-printed gold nanoparticle surfaces for the detection of low molecular weight biomolecules by laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Marsico, Alyssa L M; Creran, Brian; Duncan, Bradley; Elci, S Gokhan; Jiang, Ying; Onasch, Timothy B; Wormhoudt, Joda; Rotello, Vincent M; Vachet, Richard W

    2015-11-01

    Effective detection of low molecular weight compounds in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is often hindered by matrix interferences in the low m/z region of the mass spectrum. Here, we show that monolayer-protected gold nanoparticles (AuNPs) can serve as alternate matrices for the very sensitive detection of low molecular weight compounds such as amino acids. Amino acids can be detected at low fmol levels with minimal interferences by properly choosing the AuNP deposition method, density, size, and monolayer surface chemistry. By inkjet-printing AuNPs at various densities, we find that AuNP clusters are essential for obtaining the greatest sensitivity. Graphical Abstract ᅟ.

  18. Structural determination of the conjugate of human serum albumin with a mitomycin C derivative, KW-2149, by matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Yasuzawa, T; Tomer, K B

    1997-01-01

    A new mitomycin C derivative, KW-2149, is known to form a covalent conjugate with human serum albumin (HSA). This conjugate exhibits 1/20 of the anticellular activity of unconjugated KW-2149. Structural studies of this conjugate were carried out using a combination of enzymatic digestion, high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The tryptic peptide T5 (residues 21-41) was the only peptide found to be modified by KW-2149 moieties, the [(gamma-L-glutamylamino)ethyl]thio group or the (2-aminoethyl)thio group, through a disulfide bond. Although the latter peptide lost its mitomycin C moiety in the course of tryptic digestion, these data strongly suggest that KW-2149 was bound to Cys-34, the only free cysteine on HSA.

  19. An extraction method of positive blood cultures for direct identification of Candida species by Vitek MS matrix-assisted laser desorption ionization time of flight mass spectrometry.

    Science.gov (United States)

    Lavergne, Rose-Anne; Chauvin, Pamela; Valentin, Alexis; Fillaux, Judith; Roques-Malecaze, Christine; Arnaud, Sylvie; Menard, Sandie; Magnaval, Jean-François; Berry, Antoine; Cassaing, Sophie; Iriart, Xavier

    2013-08-01

    Candida spp. are an important cause of nosocomial bloodstream infections. Currently, complete identification of yeasts with conventional methods takes several days. We report here the first evaluation of an extraction method associated with the Vitek MS matrix-assisted laser desorption ionization time of flight mass spectrometry for direct identification of Candida species from positive blood cultures. We evaluated this protocol with blood cultures that were inoculated with reference and routine isolates (eight reference strains, 30 patients isolates and six mixed cultures containing two strains of different Candida species), or from patients with candidemia (28 isolates). This method performed extremely well (97% correct identification) with blood cultures of single Candida spp. and significantly reduced the time of diagnosis. Nevertheless, subculture remains indispensable to test fungal resistance and to detect mixed infections.

  20. Reproducibility of serum protein profiling by systematic assessment using solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry

    DEFF Research Database (Denmark)

    Callesen, Anne K; Christensen, René Depont; Madsen, Jonna S

    2008-01-01

    for serum protein profiling we investigated a range of sample preparation techniques and developed a statistical method based on repeated analyses for evaluation of protein-profiling performance of MALDI MS. Two different solid-phase extraction (SPE) methods were investigated, namely custom......Protein profiling of human serum by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is potentially a new diagnostic tool for early detection of human diseases, including cancer. Sample preparation is a key issue in MALDI MS and the analysis of complex samples such as serum......-made microcolumns and commercially available magnetic beads. Using these two methods, nineteen different sample preparation methods for serum profiling by MALDI MS were systematically tested with regard to matrix selection, stationary phase, selectivity, and reproducibility. Microcolumns were tested with regard...

  1. Comparative study of matrix-assisted laser desorption/ionization and gas chromatography for quantitative determination of cocoa butter and cocoa butter equivalent triacylglycerol composition.

    Science.gov (United States)

    Guyon, F; Absalon, Ch; Eloy, A; Salagoity, M H; Esclapez, M; Medina, B

    2003-01-01

    The triacylglycerol (TAG) composition study of cocoa butter (CB) and cocoa butter equivalents (CBEs) has been performed by gas chromatography (GC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). These two techniques provided comparable results. The advantage of the MALDI technique was the detection of each compound comprising the triacylglycerol classes (Cn). Moreover, comparison of the data obtained by these two techniques indicated that TAG relative percentages could be obtained quantitatively with the MALDI technique. These techniques have been applied for the composition determination of CB + CBE mixtures. Encouraging results showed that it is possible to quantify an admixture containing as little as 4% of CBE.

  2. Study of bisphosphonates by matrix-assisted laser desorption/ionization mass spectrometry--influence of alkali atoms on fragmentation patterns.

    Science.gov (United States)

    Guénin, Erwann; Lecouvey, Marc; Hardouin, Julie

    2009-05-01

    1-hydroxymethylene-1,1-bisphosphonic acids (or bisphosphonates) are compounds that have interesting pharmacological applications. However, few mass spectrometric investigations have been carried out to determine their fragmentation patterns. Herein, we evaluated different matrices for the study by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of the formation and fragmentation of the protonated, the cationized (MNa+ and MK+) and the deprotonated bisphosphonates. Some in-source fragmentations were observed both in positive and in negative ion modes. The fragmentation patterns obtained in post-source decay mode are also discussed. In contrast to previous electrospray ionization/multi-stage mass spectrometry (ESI-MSn) studies, some new fragmentation pathways were deduced and the effects of alkali ions on the fragmentation patterns were shown. The results summarized here completed the data previously recorded by ESI-MSn and could be used for the characterization of bisphosphonates as alkali complexes in biological mixtures.

  3. Direct Analysis of Triterpenes from High-Salt Fermented Cucumbers Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI)

    Science.gov (United States)

    Ekelöf, Måns; McMurtrie, Erin K.; Nazari, Milad; Johanningsmeier, Suzanne D.; Muddiman, David C.

    2017-02-01

    High-salt samples present a challenge to mass spectrometry (MS) analysis, particularly when electrospray ionization (ESI) is used, requiring extensive sample preparation steps such as desalting, extraction, and purification. In this study, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to a Q Exactive Plus mass spectrometer was used to directly analyze 50-μm thick slices of cucumber fermented and stored in 1 M sodium chloride brine. From the several hundred unique substances observed, three triterpenoid lipids produced by cucumbers, β-sitosterol, stigmasterol, and lupeol, were putatively identified based on exact mass and selected for structural analysis. The spatial distribution of the lipids were imaged, and the putative assignments were confirmed by tandem mass spectrometry performed directly on the same cucumber, demonstrating the capacity of the technique to deliver confident identifications from highly complex samples in molar concentrations of salt without the need for sample preparation.

  4. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry as a tool for fast identification of protein binders in color layers of paintings.

    Science.gov (United States)

    Hynek, Radovan; Kuckova, Stepanka; Hradilova, Janka; Kodicek, Milan

    2004-01-01

    Identification of materials in color layers of paintings is necessary for correct decisions concerning restoration procedures as well as proving the authenticity of the painting. The proteins are usually important components of the painting layers. In this paper it has been demonstrated that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) can be used for fast and reliable identification of proteins in color layers even in old, highly aged matrices. The digestion can be easily performed directly on silica wafers which are routinely used for infrared analysis. The amount of material necessary for such an analysis is extremely small. Peptide mass mapping using digestion with trypsin followed by MALDI-TOFMS and identification of the protein was successfully used for determination of the binder from a painting of the 19th century.

  5. Laser-induced incandescence from laser-heated silicon nanoparticles

    Science.gov (United States)

    Menser, Jan; Daun, Kyle; Dreier, Thomas; Schulz, Christof

    2016-11-01

    This work describes the application of temporally and spectrally resolved laser-induced incandescence to silicon nanoparticles synthesized in a microwave plasma reactor. Optical properties for bulk silicon presented in the literature were extended for nanostructured particles analyzed in this paper. Uncertainties of parameters in the evaporation submodel, as well as measurement noise, are incorporated into the inference process by Bayesian statistics. The inferred nanoparticle sizes agree with results from transmission electron microscopy, and the determined accommodation coefficient matches the values of the preceding study.

  6. Desorption/Ionization Fluence Thresholds and Improved Mass Spectral Consistency Measured Using a Flattop Laser Profile in the Bioaerosol Mass Spectrometry of Single Bacillus Endospores

    Energy Technology Data Exchange (ETDEWEB)

    Steele, P T; Srivastava, A; Pitesky, M E; Fergenson, D P; Tobias, H J; Gard, E E; Frank, M

    2004-11-30

    Bioaerosol mass spectrometry (BAMS) is being developed to analyze and identify biological aerosols in real-time. Mass spectra of individual Bacillus endospores were measured here with a bipolar aerosol time-of-flight mass spectrometer in which molecular desorption and ionization were produced using a single laser pulse from a Q-switched, frequency-quadrupled Nd:YAG laser that was modified to have an approximately flattop profile. The flattened laser profile allowed the minimum fluence required to desorb and ionize significant numbers of ions from single aerosol particles to be determined. For Bacillus spores this threshold had a mean value of approximately 1 nJ/{micro}m{sup 2} (0.1 J/cm{sup 2}). Thresholds for individual spores, however, could apparently deviate by 20% or more from the mean. Threshold distributions for clumps of MS2 bacteriophage and bovine serum albumin were subsequently determined. Finally, the flattened profile was observed to increase the reproducibility of single spore mass spectra. This is consistent with the general conclusions of our earlier paper on the fluence dependence of single spore mass spectra and is particularly significant because it is expected to enable more robust differentiation and identification of single bioaerosol particles.

  7. Laser-Induced Breakdown Spectroscopy in Africa

    Directory of Open Access Journals (Sweden)

    M. A. Kasem

    2015-01-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS, known also as laser-induced plasma spectroscopy (LIPS, is a well-known spectrochemical elemental analysis technique. The field of LIBS has been rapidly matured as a consequence of growing interest in real-time analysis across a broad spectrum of applied sciences and recent development of commercial LIBS analytical systems. In this brief review, we introduce the contributions of the research groups in the African continent in the field of the fundamentals and applications of LIBS. As it will be shown, the fast development of LIBS in Africa during the last decade was mainly due to the broad environmental, industrial, archaeological, and biomedical applications of this technique.

  8. Laser induced breakdown spectroscopy on meteorites

    Energy Technology Data Exchange (ETDEWEB)

    De Giacomo, A. [Department of Chemistry, University of Bari (Italy); MIP-CNR sec Bari (Italy)], E-mail: alessandro.degiacomo@ba.imip.cnr.it; Dell' Aglio, M.; De Pascale, O. [MIP-CNR sec Bari (Italy); Longo, S.; Capitelli, M. [Department of Chemistry, University of Bari (Italy); MIP-CNR sec Bari (Italy)

    2007-12-15

    The classification of meteorites when geological analysis is unfeasible is generally made by the spectral line emission ratio of some characteristic elements. Indeed when a meteorite impacts Earth's atmosphere, hot plasma is generated, as a consequence of the braking effect of air, with the consequent ablation of the falling body. Usually, by the plasma emission spectrum, the meteorite composition is determined, assuming the Boltzmann equilibrium. The plasma generated during Laser Induced Breakdown Spectroscopy (LIBS) experiment shows similar characteristics and allows one to verify the mentioned method with higher accuracy. On the other hand the study of Laser Induced Breakdown Spectroscopy on meteorite can be useful for both improving meteorite classification methods and developing on-flight techniques for asteroid investigation. In this paper certified meteorites belonging to different typologies have been investigated by LIBS: Dofhar 461 (lunar meteorite), Chondrite L6 (stony meteorite), Dofhar 019 (Mars meteorite) and Sikhote Alin (irony meteorite)

  9. Tailor-Made Stable Zr(IV)-Based Metal-Organic Frameworks for Laser Desorption/Ionization Mass Spectrometry Analysis of Small Molecules and Simultaneous Enrichment of Phosphopeptides.

    Science.gov (United States)

    Chen, Lianfang; Ou, Junjie; Wang, Hongwei; Liu, Zhongshan; Ye, Mingliang; Zou, Hanfa

    2016-08-10

    Although thousands of metal-organic frameworks (MOFs) have been fabricated and widely applied in gas storage/separations, adsorption, catalysis, and so on, few kinds of MOFs have been used as adsorption materials while simultaneously serving as matrixes to analyze small molecules for laser desorption/ionization mass spectrometry (LDI-MS). Herein, a new concept is introduced to design and synthesize MOFs as both adsorption materials and matrixes according to the structure of ligands and common matrixes. The proof of concept design was demonstrated by selection of 2,5-pyridinedicarboxylic acid (PDC) and 2,5-dihydroxyterephthalic acid (DHT) as ligands for synthesis of MOFs. Two Zr(IV)-based MOFs of UiO-66-PDC and UiO-66-(OH)2 were synthesized and applied for the first time as new matrixes for analysis of small molecules by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Both of them showed low matrix interferences, high ionization efficiency, and good reproducibility when used as matrixes. A variety of small molecules, including saccharides, amino acids, nucleosides, peptides, alkaline drugs, and natural products, were analyzed. In addition, UiO-66-(OH)2 exhibited potential for application in the quantitative determination of glucose and pyridoxal 5'-phosphate. Furthermore, thanks to its intrinsically large surface area and highly ordered pores, UiO-66-(OH)2 also showed sensitive and specific enrichment of phosphopeptides prior to MS analysis. These results demonstrated that this strategy can be used to efficiently screen tailor-made MOFs as matrixes to analyze small molecules by MALDI-TOF-MS.

  10. Fractionation of a coal tar pitch by ultra-filtration, and characterization by size exclusion chromatography, UV-fluorescence and laser desorption-mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Anthe George; Trevor J. Morgan; Patricia Alvarez; Marcos Millan; Alan A. Herod; Rafael Kandiyoti [Imperial College London, London (United Kingdom). Department of Chemical Engineering

    2010-10-15

    Ultra-filtration (UF) provides a new way of generating narrow bands of sample in the fractionation of coal and petroleum-derived liquids. It allows larger quantities of high-mass fractions to be recovered, making more detailed investigations possible, through the use of techniques requiring larger amounts of sample. In this work, UF-separated fractions have been used to study molecular mass distributions of a coal tar pitch, used as laboratory standard. The pitch was fractionated by solvent solubility into three fractions. These were further fractionated by ultra-filtration, using membranes specific to protein molecular sizes classed as '1 kDa', '5 kDa', '10 kDa' and '100 kDa'. Planar chromatography was used as a tertiary fractionation method, to sub-divide the UF-fractions. The various fractions were examined by size exclusion chromatography (SEC), UV-fluorescence spectroscopy and laser desorption-mass spectrometry (LD-MS). There was good agreement between mass estimates based on SEC and LD-MS of the smaller UF-fractions, with evidence for the presence of material with molecular masses ranging between 800 and 10,000 u. Examining the largest UF fractions of the pitch-pyridine-insoluble sample also gave clear evidence for material with molecular masses above 10,000 u. Taken together, however, the LD-MS data showed progressively diminishing differences, as the sizes of the UF membranes, and the likely molecular masses of the sample fractions, increased. One likely explanation is incomplete sampling during the laser desorption procedure. The evidence suggests that the upper mass limit detectable for these and similar samples by LD-MS has been reached. Despite these reservations, LD-MS appears as the best method to date, for investigating the mass ranges of samples derived from coal tar pitch and heavy petroleum fractions. 51 refs., 6 figs., 3 tabs.

  11. Heavy-ion induced desorption yields of amorphous carbon films bombarded with 4.2 MeV/u lead ions

    CERN Document Server

    Mahner, E; Küchler, D; Scrivens, R; Costa Pinto, P; Yin Vallgren, C; Bender, M

    2011-01-01

    During the past decade, intense experimental studies on the heavy-ion induced molecular desorption were performed in several particle accelerator laboratories worldwide in order to understand and overcome large dynamic pressure rises caused by lost beam ions. Different target materials and various coatings were studied for desorption and mitigation techniques were applied to heavy-ion accelerators. For the upgrade of the CERN injector complex, a coating of the Super Proton Synchrotron (SPS) vacuum system with a thin film of amorphous carbon is under study to mitigate the electron cloud effect observed during SPS operation with the nominal proton beam for the Large Hadron Collider (LHC). Since the SPS is also part of the heavy-ion injector chain for LHC, dynamic vacuum studies of amorphous carbon films are important to determine their ion induced desorption yields. At the CERN Heavy Ion Accelerator (LINAC 3), carbon-coated accelerator-type stainless steel vacuum chambers were tested for desorption using 4.2 Me...

  12. Laser-Induced Breakdown in Liquid Helium

    Science.gov (United States)

    Sirisky, S.; Yang, Y.; Wei, W.; Maris, H. J.

    2017-10-01

    We report on experiments in which focused laser light is used to induce optical breakdown in liquid helium-4. The threshold intensity has been measured over the temperature range from 1.1 to 2.8 K with light of wavelength 1064 nm. In addition to the measurement of the threshold, we have performed experiments to study how the breakdown from one pulse modifies the probability that a subsequent pulse will result in breakdown.

  13. Laser induced nuclear waste transmutation

    CERN Document Server

    Hirlimann, Charles

    2016-01-01

    When producing electricity that collects the mass energy that is available at the time of the induced disintegration of radioactive elements, other unstable elements are produced with half-life span durations ranging from less than one second to hundreds of thousands of years and which are considered as waste. Managing nuclear waste with a half-life of less than 30 years is an easy task, as our societies clearly know how to keep buildings safe for more than a century, the time it takes for the activity to be divided by a factor of 8. High-activity, long-lasting waste that can last for thousands of years or even longer, up to geological time laps, cannot be taken care of for such long durations. Therefore, these types of waste are socially unacceptable; nobody wants to leave a polluted planet to descendants.

  14. Laser-induced torques in metallic ferromagnets

    Science.gov (United States)

    Freimuth, Frank; Blügel, Stefan; Mokrousov, Yuriy

    2016-10-01

    We study laser-induced torques in bcc Fe, hcp Co, and L 10 FePt based on first-principles electronic structure calculations and the Keldysh nonequilibrium formalism. We find that the torques have two contributions, one from the inverse Faraday effect (IFE) and one from the optical spin-transfer torque (OSTT). Depending on the ferromagnet at hand and on the quasiparticle broadening the two contributions may be of similar magnitude, or one contribution may dominate over the other. Additionally, we determine the nonequilibrium spin polarization in order to investigate its relation to the torque. We find the torques and the perpendicular component of the nonequilibrium spin polarization to be odd in the helicity of the laser light, while the spin polarization that is induced parallel to the magnetization is helicity independent. The parallel component of the nonequilibrium spin polarization is orders of magnitude larger than the perpendicular component. In the case of hcp Co we find good agreement between the calculated laser-induced torque and a recent experiment.

  15. Applicability of a two-step laser desorption-ionization aerosol time-of-flight mass spectrometer for determination of chemical composition of ultrafine aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Laitinen, T.

    2013-11-01

    This thesis is based on the construction of a two-step laser desorption-ionization aerosol time-of-flight mass spectrometer (laser AMS), which is capable of measuring 10 to 50 nm aerosol particles collected from urban and rural air at-site and in near real time. The operation and applicability of the instrument was tested with various laboratory measurements, including parallel measurements with filter collection/chromatographic analysis, and then in field experiments in urban environment and boreal forest. Ambient ultrafine aerosol particles are collected on a metal surface by electrostatic precipitation and introduced to the time-of-flight mass spectrometer (TOF-MS) with a sampling valve. Before MS analysis particles are desorbed from the sampling surface with an infrared laser and ionized with a UV laser. The formed ions are guided to the TOF-MS by ion transfer optics, separated according to their m/z ratios, and detected with a micro channel plate detector. The laser AMS was used in urban air studies to quantify the carbon cluster content in 50 nm aerosol particles. Standards for the study were produced from 50 nm graphite particles, suspended in toluene, with 72 hours of high power sonication. The results showed the average amount of carbon clusters (winter 2012, Helsinki, Finland) in 50 nm particles to be 7.2% per sample. Several fullerenes/fullerene fragments were detected during the measurements. In boreal forest measurements, the laser AMS was capable of detecting several different organic species in 10 to 50 nm particles. These included nitrogen-containing compounds, carbon clusters, aromatics, aliphatic hydrocarbons, and oxygenated hydrocarbons. A most interesting event occurred during the boreal forest measurements in spring 2011 when the chemistry of the atmosphere clearly changed during snow melt. On that time concentrations of laser AMS ions m/z 143 and 185 (10 nm particles) increased dramatically. Exactly at the same time, quinoline concentrations

  16. The role of electron-stimulated desorption in focused electron beam induced deposition

    NARCIS (Netherlands)

    van Dorp, Willem F.; Hansen, Thomas W.; Wagner, Jakob B.; De Hosson, Jeff T. M.

    2013-01-01

    We present the results of our study about the deposition rate of focused electron beam induced processing (FEBIP) as a function of the substrate temperature with the substrate being an electron-transparent amorphous carbon membrane. When W(CO)(6) is used as a precursor it is observed that the growth

  17. Electron beam exposure mechanisms in hydrogen silsesquioxane investigated by vibrational spectroscopy and in-situ electron beam induced desorption

    Energy Technology Data Exchange (ETDEWEB)

    Olynick, D.L.; Cord, B.; Schipotinin, A.; Ogletree, D.F.; Schuck, P.J.

    2009-11-13

    Hydrogen Silsesquioxane (HSQ) is used as a high-resolution resist with resolution down below 10nm half-pitch. This material or materials with related functionalities could have widespread impact in nanolithography and nanoscience applications if the exposure mechanism was understood and instabilities controlled. Here we have directly investigated the exposure mechanism using vibrational spectroscopy (both Raman and Fourier transform Infrared) and electron beam desorption spectrocscopy (EBDS). In the non-networked HSQ system, silicon atoms sit at the corners of a cubic structure. Each silicon is bonded to a hydrogen atom and bridges 3 oxygen atoms (formula: HSiO3/2). For the first time, we have shown, via changes in the Si-H2 peak at ~;;2200 cm -1 in the Raman spectra and the release of SiHx products in EBID, that electron-bam exposed materials crosslinks via a redistribution reaction. In addition, we observe the release of significantly more H2 than SiH2 during EBID, which is indicative of additional reaction mechanisms. Additionally, we compare the behavior of HSQ in response to both thermal and electron-beam induced reactions.

  18. Pulsed laser-induced formation of silica nanogrids

    National Research Council Canada - National Science Library

    Ihlemann, Jürgen; Weichenhain-Schriever, Ruth

    2014-01-01

    ... ) coating through the transparent substrate. A polydimethylsiloxane (PDMS) superstrate (cover layer) coated on top of the SiO x film prior to laser exposure serves as confinement for controlled laser-induced structure formation...

  19. Femtosecond-laser induced dynamics of CO on Ru(0001): Deep insights from a hot-electron friction model including surface motion

    Science.gov (United States)

    Scholz, Robert; Floß, Gereon; Saalfrank, Peter; Füchsel, Gernot; Lončarić, Ivor; Juaristi, J. I.

    2016-10-01

    A Langevin model accounting for all six molecular degrees of freedom is applied to femtosecond-laser induced, hot-electron driven dynamics of Ru(0001)(2 ×2 ):CO. In our molecular dynamics with electronic friction approach, a recently developed potential energy surface based on gradient-corrected density functional theory accounting for van der Waals interactions is adopted. Electronic friction due to the coupling of molecular degrees of freedom to electron-hole pairs in the metal are included via a local density friction approximation, and surface phonons by a generalized Langevin oscillator model. The action of ultrashort laser pulses enters through a substrate-mediated, hot-electron mechanism via a time-dependent electronic temperature (derived from a two-temperature model), causing random forces acting on the molecule. The model is applied to laser induced lateral diffusion of CO on the surface, "hot adsorbate" formation, and laser induced desorption. Reaction probabilities are strongly enhanced compared to purely thermal processes, both for diffusion and desorption. Reaction yields depend in a characteristic (nonlinear) fashion on the applied laser fluence, as well as branching ratios for various reaction channels. Computed two-pulse correlation traces for desorption and other indicators suggest that aside from electron-hole pairs, phonons play a non-negligible role for laser induced dynamics in this system, acting on a surprisingly short time scale. Our simulations on precomputed potentials allow for good statistics and the treatment of long-time dynamics (300 ps), giving insight into this system which hitherto has not been reached. We find generally good agreement with experimental data where available and make predictions in addition. A recently proposed laser induced population of physisorbed precursor states could not be observed with the present low-coverage model.

  20. Laser-induced fluorescence imaging of bacteria

    Science.gov (United States)

    Hilton, Peter J.

    1998-12-01

    This paper outlines a method for optically detecting bacteria on various backgrounds, such as meat, by imaging their laser induced auto-fluorescence response. This method can potentially operate in real-time, which is many times faster than current bacterial detection methods, which require culturing of bacterial samples. This paper describes the imaging technique employed whereby a laser spot is scanned across an object while capturing, filtering, and digitizing the returned light. Preliminary results of the bacterial auto-fluorescence are reported and plans for future research are discussed. The results to date are encouraging with six of the eight bacterial strains investigated exhibiting auto-fluorescence when excited at 488 nm. Discrimination of these bacterial strains against red meat is shown and techniques for reducing background fluorescence discussed.

  1. Laser induced fluorescence of dental caries

    Science.gov (United States)

    Albin, S.; Byvik, C. E.; Buoncristiani, A. M.

    1988-01-01

    Significant differences between the optical spectra taken from sound regions of teeth and carious regions have been observed. These differences appear both in absorption and in laser induced fluorescence spectra. Excitation by the 488 nm line of an argon ion laser beam showed a peak in the emission intensity around 553 nm for the sound dental material while the emission peak from the carious region was red-shifted by approximately 40 nm. The relative absorption of carious region was significantly higher at 488 nm; however its fluorescence intensity peak was lower by an order of magnitude compared to the sound tooth. Implications of these results for a safe, reliable and early detection of dental caries are discussed.

  2. Nanodot formation induced by femtosecond laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Abere, M. J.; Kang, M.; Goldman, R. S.; Yalisove, S. M. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, C. [Applied Physics Program, University of Michigan, Ann Arbor, Michigan 48109 (United States); Rittman, D. R. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States); Phillips, J. D. [Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109 (United States); Torralva, B. [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-10-20

    The femtosecond laser generation of ZnSe nanoscale features on ZnSe surfaces was studied. Irradiation with multiple exposures produces 10–100 nm agglomerations of nanocrystalline ZnSe while retaining the original single crystal structure of the underlying material. The structure of these nanodots was verified using a combination of scanning transmission electron microscopy, scanning electron microscopy, and atomic force microscopy. The nanodots continue to grow hours after irradiation through a combination of bulk and surface diffusion. We suggest that in nanodot formation the result of ultrafast laser induced point defect formation is more than an order of magnitude below the ZnSe ultrafast melt threshold fluence. This unique mechanism of point defect injection will be discussed.

  3. Laser induced fluorescence of dental caries

    Science.gov (United States)

    Albin, S.; Byvik, C. E.; Buoncristiani, A. M.

    1988-01-01

    Significant differences between the optical spectra taken from sound regions of teeth and carious regions have been observed. These differences appear both in absorption and in laser induced fluorescence spectra. Excitation by the 488 nm line of an argon ion laser beam showed a peak in the emission intensity around 553 nm for the sound dental material while the emission peak from the carious region was red-shifted by approximately 40 nm. The relative absorption of carious region was significantly higher at 488 nm; however its fluorescence intensity peak was lower by an order of magnitude compared to the sound tooth. Implications of these results for a safe, reliable and early detection of dental caries are discussed.

  4. ARTICLES: Influence Factors on Particle Growth for On-line Aerosol Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

    Science.gov (United States)

    Xia, Wei-wei; Ti, Ru-fang; Zhang, Zi-Iiang; Zheng, Hai-yang; Fang, Li

    2010-06-01

    An evaporation/condensation flow cell was developed and interfaced with the matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometer for on-line bioaerosol detection and characterization, which allows matrix addition by condensation onto the laboratory-generated bioaerosol particles. The final coated particle exiting from the condenser is then introduced into the aerodynamic particle sizer spectrometer or home-built aerosol laser time-of-flight mass spectrometer, and its aerodynamic size directly effects on the matrix-to-analyte molar ratio, which is very important for MALDI technique. In order to observe the protonated analyte molecular ion, and then determine the classification of biological aerosols, the matrix-to-analyte molar ratio must be appropriate. Four experimental parameters, including the temperature of the heated reservoir, the initial particle size, its number concentration, and the matrix material, were tested experimentally to analyze their influences on the final particle size. This technique represents an on-line system of detection that has the potential to provide rapid and reliable identification of airborne biological aerosols.

  5. Advanced stored waveform inverse Fourier transform technique for a matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Doroshenko, V M; Cotter, R J

    1996-01-01

    The stored waveform inverse Fourier transform (SWIFT) technique is used for broadband excitation of ions in an ion-trap mass spectrometer to perform mass-selective accumulation, isolation, and fragmentation of peptide ions formed by matrix-assisted laser desorption/ionization. Unit mass resolution is achieved for isolation of ions in the range of m/z up to 1300 using a two-step isolation technique with stretched-in-time narrow band SWIFT pulses at the second stage. The effect of 'stretched-in-time' waveforms is similar to that observed previously for mass-scan-rate reduction. The asymmetry phenomenon resulting from the stretched ion-trap electrode geometry is observed during application of normal and time-reversed waveforms and is similar to the asymmetry effects observed for forward and reverse mass scans in the resonance ejection mode. Mass-selective accumulation of ions from multiple laser shots was accomplished using a method described earlier that involves increasing the trapping voltage during ion introduction for more efficient trapping of ions.

  6. Efficiency of Gas-Phase Ion Formation in Matrix-Assisted Laser Desorption Ionization with 2,5-Dihydroxybenzoic Acid as Matrix

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Man; Ahn, Sung Hee; Bae, Yong Jin; Kim, Myung Soo [Seoul National Univ., Seoul (Korea, Republic of)

    2013-03-15

    Numbers of matrix- and analyte-derived ions and their sum in matrix-assisted laser desorption ionization (MALDI) of a peptide were measured using 2,5-dihydroxybenzoic acid (DHB) as matrix. As for MALDI with α-cyano-4-hydroxy cinnamic acid as matrix, the sum was independent of the peptide concentration in the solid sample, or was the same as that of pure DHB. This suggested that the matrix ion was the primary ion and that the peptide ion was generated by matrix-to-peptide proton transfer. Experimental ionization efficiencies of 10{sup -5}-10{sup -4} for peptides and 10{sup -8}-10{sup -7} for matrices are far smaller than 10.3-10.1 for peptides and 10{sup -5}-10{sup -3} for matrices speculated by Hillenkamp and Karas. Number of gas-phase ions generated by MALDI was unaffected by laser wavelength or pulse energy. This suggests that the main role of photo-absorption in MALDI is not in generating ions via a multi-photon process but in ablating materials in a solid sample to the gas phase.

  7. Laser induced single spot oxidation of titanium

    Energy Technology Data Exchange (ETDEWEB)

    Jwad, Tahseen, E-mail: taj355@bham.ac.uk; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-11-30

    Highlights: • A new high resolution laser induced oxidation (colouring) method is proposed (single spot oxidation). • The method is applied to control oxide films thicknesses and hence colours on titanium substrates in micro-scale. • The method enable imprinting high resolution coloured image on Ti substrate. • Optical and morphological periodic surface structures are also produced by an array of oxide spots using the proposed method. • Colour coding of two colours into one field is presented. - Abstract: Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels’ colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  8. Laser-Induced Incandescence in Microgravity

    Science.gov (United States)

    VanderWal, Randy L.

    1997-01-01

    Knowledge of soot concentration is important due to its presence and impact upon a wide range of combustion processes ranging from diffusion to premixed flames, laminar to turbulent processes and homogeneous to heterogeneous combustion. Measurement of soot volume fraction (f(sub v)) is essential to discerning its formation and growth. The presence of soot also affects other physical and chemical properties of combustion thereby affecting studies not directly concerned with either its formation or growth, such as radiative heat transfer, CO oxidation and fuel vaporization or pyrolysis rates. Microgravity offers unique opportunities for studying both soot growth and the effect of soot radiation upon flame structure and spread. Spatial scales and residence time scales are greatly extended in 0-g facilitating soot growth studies. With the varied geometries, short duration microgravity test times and time-varying processes there is a demand for measurement of f(sub v) with high spatial and temporal resolution. Laser-induced incandescence (LII) has advanced f(sub v) measurements in many 1-g combustion processes. To create laser-induced incandescence, a pulsed high intensity laser heats soot to incandescence temperatures. Using appropriate spectral and temporal detection conditions, the resulting incandescence can be selectively detected apart from the non-laser-heated soot and flame gases. Theoretical modelling and experiments have shown that the resulting incandescence is representative of f(sub v). Using an intensified array camera and a laser sheet for excitation, one- and two-dimensionally resolved LII images of f(sub v) have been obtained in 1-g. LII has been characterized and developed at NASA-Lewis for soot volume fraction determination in a wide range of 1-g combustion applications. Broadly grouped, the characterization work has included studies of excitation intensity, excitation wavelength and the optimum temporal and spectral detection conditions to enable an

  9. Carbon Dots and 9AA as a Binary Matrix for the Detection of Small Molecules by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

    Science.gov (United States)

    Chen, Yongli; Gao, Dan; Bai, Hangrui; Liu, Hongxia; Lin, Shuo; Jiang, Yuyang

    2016-07-01

    Application of matrix-assisted laser-desorption/ionization mass spectrometry (MALDI MS) to analyze small molecules have some limitations, due to the inhomogeneous analyte/matrix co-crystallization and interference of matrix-related peaks in low m/z region. In this work, carbon dots (CDs) were for the first time applied as a binary matrix with 9-Aminoacridine (9AA) in MALDI MS for small molecules analysis. By 9AA/CDs assisted desorption/ionization (D/I) process, a wide range of small molecules, including nucleosides, amino acids, oligosaccharides, peptides, and anticancer drugs with a higher sensitivity were demonstrated in the positive ion mode. A detection limit down to 5 fmol was achieved for cytidine. 9AA/CDs matrix also exhibited excellent reproducibility compared with 9AA matrix. Moreover, by exploring the ionization mechanism of the matrix, the influence factors might be attributed to the four parts: (1) the strong UV absorption of 9AA/CDs due to their π-conjugated network; (2) the carboxyl groups modified on the CDs surface act as protonation sites for proton transfer in positive ion mode; (3) the thin layer crystal of 9AA/CDs could reach a high surface temperature more easily and lower transfer energy for LDI MS; (4) CDs could serve as a matrix additive to suppress 9AA ionization. Furthermore, this matrix was allowed for the analysis of glucose as well as nucleosides in human urine, and the level of cytidine was quantified with a linear range of 0.05-5 mM (R(2) > 0.99). Therefore, the 9AA/CDs matrix was proven to be an effective MALDI matrix for the analysis of small molecules with improved sensitivity and reproducibility. This work provides an alternative solution for small molecules detection that can be further used in complex samples analysis. Graphical Abstract ᅟ.

  10. Carbon Dots and 9AA as a Binary Matrix for the Detection of Small Molecules by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

    Science.gov (United States)

    Chen, Yongli; Gao, Dan; Bai, Hangrui; Liu, Hongxia; Lin, Shuo; Jiang, Yuyang

    2016-07-01

    Application of matrix-assisted laser-desorption/ionization mass spectrometry (MALDI MS) to analyze small molecules have some limitations, due to the inhomogeneous analyte/matrix co-crystallization and interference of matrix-related peaks in low m/z region. In this work, carbon dots (CDs) were for the first time applied as a binary matrix with 9-Aminoacridine (9AA) in MALDI MS for small molecules analysis. By 9AA/CDs assisted desorption/ionization (D/I) process, a wide range of small molecules, including nucleosides, amino acids, oligosaccharides, peptides, and anticancer drugs with a higher sensitivity were demonstrated in the positive ion mode. A detection limit down to 5 fmol was achieved for cytidine. 9AA/CDs matrix also exhibited excellent reproducibility compared with 9AA matrix. Moreover, by exploring the ionization mechanism of the matrix, the influence factors might be attributed to the four parts: (1) the strong UV absorption of 9AA/CDs due to their π-conjugated network; (2) the carboxyl groups modified on the CDs surface act as protonation sites for proton transfer in positive ion mode; (3) the thin layer crystal of 9AA/CDs could reach a high surface temperature more easily and lower transfer energy for LDI MS; (4) CDs could serve as a matrix additive to suppress 9AA ionization. Furthermore, this matrix was allowed for the analysis of glucose as well as nucleosides in human urine, and the level of cytidine was quantified with a linear range of 0.05-5 mM (R2 > 0.99). Therefore, the 9AA/CDs matrix was proven to be an effective MALDI matrix for the analysis of small molecules with improved sensitivity and reproducibility. This work provides an alternative solution for small molecules detection that can be further used in complex samples analysis.

  11. Laser-Induced Breakdown Spectroscopy: Capabilities and Applications

    Science.gov (United States)

    2010-07-01

    sample preparation. 14 6. References 1. Cremers D.A.; Radziemski, L. J. Handbook of Laser-Induced Breakdown Spectroscopy; West Sussex, England...30 (21), 2882–2884. 17. Salle, B.; Lacour, J. L.; Vors, E.; Fichet, P.; Maurice, S.; Cremers , D. A.; et al. Laser- Induced Breakdown Spectroscopy...90. Martin , M. Z.; Labbe, N.; Andre, N.; Harris, R.; Ebinger, M.; Wullschleger, S. D.; et al. High Resolution Applications of Laser-Induced

  12. Enzymatic lipid removal from surfaces--lipid desorption by a pH-induced "electrostatic explosion".

    Science.gov (United States)

    Snabe, Torben; Neves-Petersen, Maria Teresa; Petersen, Steffen Bjørn

    2005-01-01

    Removal of lipidic molecules from surfaces can be accomplished using detergents containing lipases. Surface cleaning is usually performed under alkaline conditions due to increased solubility of the hydrolysis products, especially free fatty acids. This paper shows that removal of a triacylglycerol film from a surface can be dramatically enhanced in a sequential system where pH is shifted to alkaline conditions after an initial lipolytic reaction period at or below neutral pH. Data from three different biophysical techniques, attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), quartz crystal microbalance with dissipation monitoring (QCM-D), and total internal reflection fluorescence spectroscopy (TIRF) clearly show the effects of such cleaning procedure. Initially the reaction is carried out at pH below the pKa value of the fatty acids formed upon triacylglycerol hydrolysis, and the protonated fatty acids accumulate in the film. The mechanism of lipid removal, induced by increasing pH to a value above the fatty acid pKa, is explained by a burst caused by electrostatic repulsion between rapidly ionised fatty acids, i.e. by an "electrostatic explosion". Performing the initial hydrolysis at pH 6 and the subsequent rinse at pH 10, using triolein as model substrate, lipid removal from surfaces by both commercial detergent lipases and non-commercial lipases was significantly improved compared to a reaction at constant pH 10.

  13. Laser-induced breakdown spectroscopy in Asia

    Science.gov (United States)

    Wang, Zhen-Zhen; Deguchi, Yoshihiro; Zhang, Zhen-Zhen; Wang, Zhe; Zeng, Xiao-Yan; Yan, Jun-Jie

    2016-12-01

    Laser-induced breakdown spectroscopy (LIBS) is an analytical detection technique based on atomic emission spectroscopy to measure the elemental composition. LIBS has been extensively studied and developed due to the non-contact, fast response, high sensitivity, real-time and multi-elemental detection features. The development and applications of LIBS technique in Asia are summarized and discussed in this review paper. The researchers in Asia work on different aspects of the LIBS study in fundamentals, data processing and modeling, applications and instrumentations. According to the current research status, the challenges, opportunities and further development of LIBS technique in Asia are also evaluated to promote LIBS research and its applications.

  14. Laser induced single spot oxidation of titanium

    Science.gov (United States)

    Jwad, Tahseen; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-11-01

    Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels' colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  15. A method to detect metal-drug complexes and their interactions with pathogenic bacteria via graphene nanosheet assist laser desorption/ionization mass spectrometry and biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Abdelhamid, Hani Nasser [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Wu, Hui-Fen, E-mail: hwu@faculty.nsysu.edu.tw [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, 800, Taiwan (China); Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Doctoral Degree Program in Marine Biotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China)

    2012-11-02

    Highlights: Black-Right-Pointing-Pointer Probe transition metals-complexes based on noncovalent functionalized graphene for MALDI-MS. Black-Right-Pointing-Pointer Study interaction of transition metals complexes with pathogenic bacteria. Black-Right-Pointing-Pointer Propose a new biosensor for two pathogenic bacteria. - Abstract: A new method was proposed to probe the interactions between transition metals of Fe(II), Fe(III), Cu(II) with a non steroidal anti-inflammatory drug (NSAID), flufenamic acid (FF) using graphene as a matrix for Graphene assisted laser desorption ionization mass spectrometry (GALDI-MS). Metal-drug complexation was confirmed via UV absorption spectroscopy, fluorescence spectroscopy, pH meter, and change in solution conductivity. The optimal molar ratios for these complexation interactions are stoichiometry 1:2 in both Cu(II) and Fe(II) complexes, and 1:3 in Fe(III) complexes at physiological pH (7.4). Metal complexation of the drug could enhance fluorescence for 20 fold which is due to the charge transfer reaction or increase rigidity of the drug. The main interaction between graphene and flufenamic acid is the {Pi}-{Pi} interaction which allows us to probe the metal-drug complexation. The GALDI-MS could sensitively detect the drug at m/z 281.0 Da (protonated molecule) with detection limit 2.5 pmol (1.0 {mu}M) and complexation at m/z 661.0, 654.0 and 933.0 Da corresponding to [Cu(II)(FF){sub 2}(H{sub 2}O){sub 2} + H]{sup +}, [Fe(II)(FF){sub 2}(H{sub 2}O){sub 2} + H]{sup +} and [Fe(III) (FF){sub 3}(H{sub 2}O){sub 2} + H]{sup +}, respectively (with limit of detection (LOD) 2.0 pmol (10.0 {mu}M). Matrix assisted laser desorption ionization mass spectrometry (MALDI-MS) spectra show change in the protein profile of intact pathogenic bacteria (Pseudomonas aeroginosa, Staphylococcus aureus). The change in the ionization ability (mainly proton affinity) of pathogenic bacteria may be due to the interactions between the bacteria with the drug (or its

  16. Sequencing of phosphopeptides sulfonated by 4-sulfophenyl isothiocyanate using post-source decay matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    TANG Jianguang; WANG Yongjun; ZHANG Hainan; WANG Chunyu; HU Zhiping; XUE Zhigang; XIA Kun; SHI Xiaoliu

    2006-01-01

    Phosphorylation/dephosphorylation is probably the most common and important reversible post-translational modificaion of proteins. Analyzing the functional effects of phosphorylation is helpful for understanding the biological functions of proteins. Identification of the phosphorylation sites of phosphorylated protein is a prerequisite for research on phosphorylation. In this work, an effective and simple method of identification of protein phosphorylation sites has been developed. Phosphopeptides were selectively enriched with immobilized metal affinity chromatography (IMAC) and subsequently chemically modified by 4-sulfophenyl isothiocyanate, and then the chemically modified phosphopeptides were sequenced with post-source decay (PSD) matrix-assisted laser desorption/ionization (MALDI)time-of-flight mass spectrometry for detecting phosphorylation sites. The charge of derivatization by 4-sulfophenyl isothiocyanate introduces a negative sulfonic acid group at the N-terminus of a peptide, and enables the selective detection of only a single series of C-terminal y-type ions. This chemically assisted method greatly simplifies the extremely complex pattern of PSD fragment ions and makes the PSD spectra more easier to be interpreted. The phosphorylation sites of a synthesized model phosphopeptide and human c-myc protein have been successfully identified by this method.Phosphorylation/dephosphorylation is probably the most common and important reversible post-translational modificaion of proteins. Analyzing the functional effects of phosphorylation is helpful for understanding the biological functions of proteins. Identification of the phosphorylation sites of phosphorylated protein is a prerequisite for research on phosphorylation. In this work, an effective and simple method of identification of protein phosphorylation sites has been developed. Phosphopeptides were selectively enriched with immobilized metal affinity chromatography (IMAC) and subsequently chemically

  17. Study of the photon-induced formation and subsequent desorption of CH3 OH and H2 CO in interstellar ice analogs

    CERN Document Server

    Martín-Doménech, R; Cruz-Díaz, G A

    2016-01-01

    Methanol and formaldehyde are two simple organic molecules that are ubiquitously detected in the interstellar medium. An origin in the solid phase and a subsequent nonthermal desorption into the gas phase is often invoked to explain their abundances in some of the environments where they are found. Experimental simulations under astrophysically relevant conditions have been carried out to find a suitable mechanism for that process. We explore the in situ formation and subsequent photon-induced desorption of these species, studying the UV photoprocessing of pure ethanol ice, and a more realistic binary H2O:CH4 ice analog. Ice samples deposited onto an infrared transparent window at 8 K were UV-irradiated using a microwave-discharged hydrogen flow lamp. Evidence of photochemical production of these two species and subsequent UV-photon-induced desorption into the gas phase were searched for by means of a Fourier transform infrared spectrometer and a quadrupole mass spectrometer, respectively. Formation of CH3OH ...

  18. Identification and Quantification of N-Acyl Homoserine Lactones Involved in Bacterial Communication by Small-Scale Synthesis of Internal Standards and Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

    Science.gov (United States)

    Leipert, Jan; Treitz, Christian; Leippe, Matthias; Tholey, Andreas

    2017-08-01

    N-acyl homoserine lactones (AHL) are small signal molecules involved in the quorum sensing of many gram-negative bacteria, and play an important role in biofilm formation and pathogenesis. Present analytical methods for identification and quantification of AHL require time-consuming sample preparation steps and are hampered by the lack of appropriate standards. By aiming at a fast and straightforward method for AHL analytics, we investigated the applicability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Suitable MALDI matrices, including crystalline and ionic liquid matrices, were tested and the fragmentation of different AHL in collision-induced dissociation MS/MS was studied, providing information about characteristic marker fragments ions. Employing small-scale synthesis protocols, we established a versatile and cost-efficient procedure for fast generation of isotope-labeled AHL standards, which can be used without extensive purification and yielded accurate standard curves. Quantitative analysis was possible in the low pico-molar range, with lower limits of quantification reaching from 1 to 5 pmol for different AHL. The developed methodology was successfully applied in a quantitative MALDI MS analysis of low-volume culture supernatants of Pseudomonas aeruginosa. [Figure not available: see fulltext.

  19. Femtosecond laser induced microripple on PDMS surface

    Institute of Scientific and Technical Information of China (English)

    Jin Xie; Changhe Zhou; Wei Wang; Tengfei Wu

    2009-01-01

    laser pulses and the subsequent cool-down solidification of the melting PDMS along with the movement of the femtosecond laser spot. This result will be helpful to understand the interaction between the femtosecond laser and the polymer.

  20. [Data analysis of laser desorption/ionization mass spectrum of individual particle using adaptive resonance theory based neural network].

    Science.gov (United States)

    Lin, Ying; Guo, Xiao-Yong; Gu, Xue-Jun; Xia, Wei-Wei; Zheng, Hai-Yang; Zhang, Wei-Jun; Fang, Li

    2009-03-01

    On-line measurement of size and chemical composition of single particle using an aerosol laser time-of-flight mass spectrometer (ALTOFMS) was designed in our lab. Each particle's aerodynamic diameter is determined by measuring the delay time between two continuous-wave lasers operating at 650 nm. A Nd : YAG laser desorbs and ionizes molecules from the particle, and the time-of-flight mass spectrometer collects a mass spectrum of the generated ions. Then the composition of single particle is obtained. ALTOFMS generates large amount of data during the process period. How to process these data quickly and extract valuable information is one of the key problems for the ALTOFMS. In the present paper, an adaptive resonance theory-based neural network, ART-2a algorithm, was used to classify mixed mass spectra of aerosol particles of NaCl, CaCl2, dioctylphthalate (DOP), and 2,5-dihydroxybenzoic acid (DHB). Compared with the traditional methods, ART-2a can recognize input patterns self-organically, self-adaptively and self-steadily without considering the complexity and the number of the patterns, so it is more favorable for the analysis of the mass spectra data. Experimental results show that when vigilance parameter is 0.40, learning rate is 0.05 and iteration number is 6, ART-2a algorithm can successfully reveal these four particle categories. The weight vectors for these four particle classes were obtained, which can represent the characters of these four particle classes remarkably.

  1. Minimally invasive non-thermal laser technology using laser-induced optical breakdown for skin rejuvenation

    NARCIS (Netherlands)

    Habbema, L.; Verhagen, R.; Van Hal, R.; Liu, Y.; Varghese, B.

    2011-01-01

    We describe a novel, minimally invasive laser technology for skin rejuvenation by creating isolated microscopic lesions within tissue below the epidermis using laser induced optical breakdown. Using an in-house built prototype device, tightly focused near-infrared laser pulses are used to create opt

  2. Minimally invasive non-thermal laser technology using laser-induced optical breakdown for skin rejuvenation

    NARCIS (Netherlands)

    Habbema, L.; Verhagen, R.; Van Hal, R.; Liu, Y.; Varghese, B.

    2011-01-01

    We describe a novel, minimally invasive laser technology for skin rejuvenation by creating isolated microscopic lesions within tissue below the epidermis using laser induced optical breakdown. Using an in-house built prototype device, tightly focused near-infrared laser pulses are used to create

  3. Structure determination of two conotoxins from Conus textile by a combination of matrix-assisted laser desorption/ionization time-of-flight and electrospray ionization mass spectrometry and biochemical methods

    DEFF Research Database (Denmark)

    Kalume, D E; Stenflo, J; Czerwiec, E

    2000-01-01

    Two highly modified conotoxins from the mollusc Conus textile, epsilon-TxIX and Gla(1)-TxVI, were characterized by matrix-assisted laser desorption/ionization and electrospray mass spectrometry and also by electrospray ionization tandem and triple mass spectrometry in combination with enzymatic c...... esterification was found necessary for the site-specific assignment of the Gla residues in the peptides....

  4. Comparison of the Accuracy of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry with That of Other Commercial Identification Systems for Identifying Staphylococcus saprophyticus in Urine

    Science.gov (United States)

    Lee, Tai-Fen; Lee, Hao; Chen, Chung-Ming; Du, Shin-Hei; Cheng, Ya-Chih; Hsu, Chen-Ching; Chung, Meng-Yu; Teng, Shih-Hua; Teng, Lee-Jene

    2013-01-01

    Among 30 urinary isolates of Staphylococcus saprophyticus identified by sequencing methods, the rate of accurate identification was 100% for Bruker Biotyper matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS), 86.7% for the Phoenix PID and Vitek 2 GP systems, 93.3% for the MicroScan GP33 system, and 46.7% for the BBL CHROMagar Orientation system. PMID:23390286

  5. Rapid Identification of Bacteria Directly from Positive Blood Cultures by Use of a Serum Separator Tube, Smudge Plate Preparation, and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Chen, Yan; Porter, Vanessa; Mubareka, Samira; Kotowich, Leona; Simor, Andrew E

    2015-10-01

    We analyzed the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) of smudge plate growth for bacterial identification from 400 blood cultures. Ninety-seven percent of Gram-negative bacilli and 85% of Gram-positive organisms were correctly identified within 4 h; only eight isolates (2.0%) were misidentified. This method provided rapid and accurate microbial identification from positive blood cultures.

  6. Amazonian Vegetable Oils and Fats: Fast Typification and Quality Control via Triacylglycerol (TAG) Profiles from Dry Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry Fingerprinting

    OpenAIRE

    Saraiva, Sergio A.; Cabral, Elaine C; Eberlin, Marcos N; Rodrigo R. Catharino

    2009-01-01

    Amazonian oils and fats display unique triacylglycerol (TAG) profiles and, because of their economic importance as renewable raw materials and use by the cosmetic and food industries, are often subject to adulteration and forgery. Representative samples of these oils (andiroba, Brazil nut, buriti, and passion fruit) and fats (cupuacu, murumuru, and ucuba) were characterized without pre-separation or derivatization via dry (solvent-free) matrix-assisted laser desorption/ionization time-of-flig...

  7. Comparison of the accuracy of matrix-assisted laser desorption ionization-time of flight mass spectrometry with that of other commercial identification systems for identifying Staphylococcus saprophyticus in urine.

    Science.gov (United States)

    Lee, Tai-Fen; Lee, Hao; Chen, Chung-Ming; Du, Shin-Hei; Cheng, Ya-Chih; Hsu, Chen-Ching; Chung, Meng-Yu; Teng, Shih-Hua; Teng, Lee-Jene; Hsueh, Po-Ren

    2013-05-01

    Among 30 urinary isolates of Staphylococcus saprophyticus identified by sequencing methods, the rate of accurate identification was 100% for Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS), 86.7% for the Phoenix PID and Vitek 2 GP systems, 93.3% for the MicroScan GP33 system, and 46.7% for the BBL CHROMagar Orientation system.

  8. Ghost peaks observed after atmospheric pressure matrix-assisted laser desorption/ionization experiments may disclose new ionization mechanism of matrix-assisted hypersonic velocity impact ionization.

    Science.gov (United States)

    Moskovets, Eugene

    2015-08-30

    Understanding the mechanisms of matrix-assisted laser desorption/ionization (MALDI) promises improvements in the sensitivity and specificity of many established applications in the field of mass spectrometry. This paper reports a serendipitous observation of a significant ion yield in a post-ionization experiment conducted after the sample had been removed from a standard atmospheric pressure (AP)-MALDI source. This post-ionization is interpreted in terms of collisions of microparticles moving with a hypersonic velocity into a solid surface. Calculations show that the thermal energy released during such collisions is close to that absorbed by the top matrix layer in traditional MALDI. The microparticles, containing both the matrix and analytes, could be detached from a film produced inside the inlet capillary during the sample ablation and accelerated by the flow rushing through the capillary. These observations contribute some new perspective to ion formation in both laser and laser-less matrix-assisted ionization. An AP-MALDI ion source hyphenated with a three-stage high-pressure ion funnel system was utilized for peptide mass analysis. After the laser had been turned off and the MALDI sample removed, ions were detected during a gradual reduction of the background pressure in the first funnel. The constant-rate pressure reduction led to the reproducible appearance of different singly and doubly charged peptide peaks in mass spectra taken a few seconds after the end of the MALDI analysis of a dried-droplet spot. The ion yield as well as the mass range of ions observed with a significant delay after a completion of the primary MALDI analysis depended primarily on the background pressure inside the first funnel. The production of ions in this post-ionization step was exclusively observed during the pressure drop. A lower matrix background and significant increase in relative yield of double-protonated ions are reported. The observations were partially consistent

  9. Laser induced phase locking of hydrogen plasma striations

    Energy Technology Data Exchange (ETDEWEB)

    Glab, W.; Nayfeh, M.H.

    1982-04-01

    Laser induced transient striations of a hydrogen discharge plasma are studied as a function of the ''detuning'' of the discharge parameters from the steady-state oscillatory response conditions. We observed laser induced phase locking of the steady-state striations.

  10. Laser Induced Selective Activation For Subsequent Autocatalytic Electroless Plating

    DEFF Research Database (Denmark)

    Zhang, Yang

    The subject of this PhD thesis is “Laser induced selective activation for subsequent autocatalytic electroless plating.” The objective of the project is to investigate the process chains for micro structuring of polymer surfaces for selective micro metallization. Laser induced selective activation...

  11. Evaluation of a simple protein extraction method for species identification of clinically relevant staphylococci by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Matsuda, Naoto; Matsuda, Mari; Notake, Shigeyuki; Yokokawa, Hirohide; Kawamura, Yoshiaki; Hiramatsu, Keiichi; Kikuchi, Ken

    2012-12-01

    In clinical microbiology, bacterial identification is labor-intensive and time-consuming. A solution for this problem is the use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). In this study, we evaluated a modified protein extraction method of identification performed on target plates (on-plate extraction method) with MALDI-TOF (Bruker Microflex LT with Biotyper version 3.0) and compared it to 2 previously described methods: the direct colony method and a standard protein extraction method (standard extraction method). We evaluated the species of 273 clinical strains and 14 reference strains of staphylococci. All isolates were characterized using the superoxide dismutase A sequence as a reference. For the species identification, the on-plate, standard extraction, and direct colony methods identified 257 isolates (89.5%), 232 isolates (80.8%), and 173 isolates (60.2%), respectively, with statistically significant differences among the three methods (P extraction method is at least as good as standard extraction in identification rate and has the advantage of a shorter processing time.

  12. Sample-first preparation: a method for surface-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of cyclic oligosaccharides.

    Science.gov (United States)

    Wu, Hsin-Pin; Su, Chih-Lin; Chang, Hui-Chiu; Tseng, Wei-Lung

    2007-08-15

    A new sample preparation method for the analysis of cyclic oligosaccharides in surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) is presented. We call this new technique "sample first method", in which a sample is deposited first and then bare gold nanoparticles (AuNPs), which serve as the SALDI matrixes, are added to the top of the sample layer. The use of the sample first method offers significant advantages for improving shot-to-shot reproducibility, enhancing the ionization efficiency of the analyte, and reducing sample preparation time as compared to the dried-droplet method, wherein samples and bare AuNPs are mixed and dried together. The relative standard deviation (RSD) values of the signal intensity as calculated from 65 sample spots was 25% when the sample first methods were applied to the analysis of beta-cyclodextrin. The results were more homogeneous as compared to the outcome using dried-droplet preparation of AuNPs (RSD=66%) and 2,5-dihydroxybenzoic acid (RSD=209%). We also found out that the optimal concentration of AuNP for ionization efficiency is 7.4 nM (4.52x10(12) particles/mL) while the lowest detectable concentration of cyclic oligosaccharides through this approach is 0.25 microM. Except for the cyclic oligosaccharide, the proposed method was also applied to the analyses of other biological samples, including neutral carbohydrate and steroid, aminothiols, and peptides as well as proteins.

  13. An evaluation of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the identification of Staphylococcus pseudintermedius isolates from canine infections.

    Science.gov (United States)

    Silva, Marcella Braga; Ferreira, Fabienne Antunes; Garcia, Luize Neli Nunes; Silva-Carvalho, Maria Cícera; Botelho, Larissa Alvarenga Batista; Figueiredo, Agnes Marie Sá; Vieira-da-Motta, Olney

    2015-03-01

    It has been proposed, based on taxonomic and molecular studies, that all canine isolates belonging to Staphylococcus intermedius group (SIG) should be renamed Staphylococcus pseudintermedius. However, isolates of SIG and other coagulase-positive staphylococci share many phenotypic characteristics, which could lead to misidentification. The accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identifying S. pseudintermedius isolates obtained from canine infections was evaluated, using a polymerase chain reaction (PCR)-based identification as the gold standard. In addition, MALDI-TOF MS was compared with conventional biochemical tests. A central problem was the incorrect identification of S. pseudintermedius isolates as S. intermedius by either MALDI-TOF MS or biochemical identification. From the 49 S. pseudintermedius isolates identified by the molecular method, only 21 could be assigned to this species by the biochemical approach and only 12 by MALDI-TOF MS. The 6 S. aureus isolates were correctly identified by all 3 techniques. However, using biochemical tests, 9 S. pseudintermedius were mistakenly classified as S. aureus, indicating a reduced specificity relative to the MALDI-TOF MS system. Analysis with the MALDI-TOF MS platform allowed rapid and accurate identification of the 49 isolates to the S. intermedius group but the approach was very limited in identifying S. pseudintermedius isolates, as only 12 of 49 isolates were correctly identified, a sensitivity of 0.24 (95% confidence interval: 0.13-0.39).

  14. Detection of bacteria from biological mixtures using immunomagnetic separation combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    Science.gov (United States)

    Madonna, A.J.; Basile, F.; Furlong, E.; Voorhees, K.J.

    2001-01-01

    A rapid method for identifying specific bacteria from complex biological mixtures using immunomagnetic separation coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been developed. The technique employs commercially available magnetic beads coated with polycolonal antibodies raised against specific bacteria and whole cell analysis by MALDI-MS. A suspension of a bacterial mixture is mixed with the immunomagnetic beads specific for the target microorganism. After a short incubation period (20 mins) the bacteria captured by the beads are washed, resuspended in deionized H2O and directly applied onto a MALDI probe. Liquid suspensions containing bacterial mixtures can be screened within 1 h total analysis time. Positive tests result in the production of a fingerprint mass spectrum primarily consisting of protein biomarkers characteristic of the targeted microorganism. Using this procedure, Salmonella choleraesuis was isolated and detected from standard bacterial mixtures and spiked samples of river water, human urine, and chicken blood. Copyright ?? 2001 John Wiley & Sons, Ltd.

  15. Evaluation of the Andromas matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of aerobically growing Gram-positive bacilli.

    Science.gov (United States)

    Farfour, E; Leto, J; Barritault, M; Barberis, C; Meyer, J; Dauphin, B; Le Guern, A-S; Leflèche, A; Badell, E; Guiso, N; Leclercq, A; Le Monnier, A; Lecuit, M; Rodriguez-Nava, V; Bergeron, E; Raymond, J; Vimont, S; Bille, E; Carbonnelle, E; Guet-Revillet, H; Lécuyer, H; Beretti, J-L; Vay, C; Berche, P; Ferroni, A; Nassif, X; Join-Lambert, O

    2012-08-01

    Matrix-associated laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a rapid and simple microbial identification method. Previous reports using the Biotyper system suggested that this technique requires a preliminary extraction step to identify Gram-positive rods (GPRs), a technical issue that may limit the routine use of this technique to identify pathogenic GPRs in the clinical setting. We tested the accuracy of the MALDI-TOF MS Andromas strategy to identify a set of 659 GPR isolates representing 16 bacterial genera and 72 species by the direct colony method. This bacterial collection included 40 C. diphtheriae, 13 C. pseudotuberculosis, 19 C. ulcerans, and 270 other Corynebacterium isolates, 32 L. monocytogenes and 24 other Listeria isolates, 46 Nocardia, 75 Actinomyces, 18 Actinobaculum, 11 Propionibacterium acnes, 18 Propionibacterium avidum, 30 Lactobacillus, 21 Bacillus, 2 Rhodococcus equi, 2 Erysipelothrix rhusiopathiae, and 38 other GPR isolates, all identified by reference techniques. Totals of 98.5% and 1.2% of non-Listeria GPR isolates were identified to the species or genus level, respectively. Except for L. grayi isolates that were identified to the species level, all other Listeria isolates were identified to the genus level because of highly similar spectra. These data demonstrate that rapid identification of pathogenic GPRs can be obtained without an extraction step by MALDI-TOF mass spectrometry.

  16. Matrix-assisted laser desorption/ionization mass spectrometry imaging: a powerful tool for probing the molecular topology of plant cutin polymer.

    Science.gov (United States)

    Veličković, Dušan; Herdier, Hélène; Philippe, Glenn; Marion, Didier; Rogniaux, Hélène; Bakan, Bénédicte

    2014-12-01

    The cutin polymers of different fruit cuticles (tomato, apple, nectarine) were examined using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) after in situ release of the lipid monomers by alkaline hydrolysis. The mass spectra were acquired from each coordinate with a lateral spatial resolution of approximately 100 μm. Specific monomers were released at their original location in the tissue, suggesting that post-hydrolysis diffusion can be neglected. Relative quantification of the species was achieved by introducing an internal standard, and the collection of data was subjected to non-supervised and supervised statistical treatments. The molecular images obtained showed a specific distribution of ions that could unambiguously be ascribed to cutinized and suberized regions observed at the surface of fruit cuticles, thus demonstrating that the method is able to probe some structural changes that affect hydrophobic cuticle polymers. Subsequent chemical assignment of the differentiating ions was performed, and all of these ions could be matched to cutin and suberin molecular markers. Therefore, this MALDI-MSI procedure provides a powerful tool for probing the surface heterogeneity of plant lipid polymers. This method should facilitate rapid investigation of the relationships between cuticle phenotypes and the structure of cutin within a large population of mutants.

  17. Applications of whole-cell matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry in systematic microbiology.

    Science.gov (United States)

    Welker, Martin; Moore, Edward R B

    2011-02-01

    In the last few years matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been increasingly studied and applied for the identification and typing of microorganisms. Very recently, MALDI-TOF MS has been introduced in clinical routine microbiological diagnostics with marked success, which is remarkable considering that not long ago the technology was generally seen as being far from practical application. The identification of microbial isolates by whole-cell mass spectrometry (WC-MS) is being recognized as one of the latest tools forging a revolution in microbial diagnostics, with the potential of bringing to an end many of the time-consuming and man-power-intensive identification procedures that have been used for decades. Apart from applications of WC-MS in clinical diagnostics, other fields of microbiology also have adopted the technology with success. In this article, an over-view of the principles of MALDI-TOF MS and WC-MS is presented, highlighting the characteristics of the technology that allow its utilization for systematic microbiology.

  18. Differentiation of Lactobacillus brevis strains using Matrix-Assisted-Laser-Desorption-Ionization-Time-of-Flight Mass Spectrometry with respect to their beer spoilage potential.

    Science.gov (United States)

    Kern, Carola C; Vogel, Rudi F; Behr, Jürgen

    2014-06-01

    Lactobacillus (L.) brevis is one of the most frequently encountered bacteria in beer-spoilage incidents. As the species Lactobacillus brevis comprises strains showing varying ability to grow in beer, ranging from growth in low hopped wheat to highly hopped pilsner beer, differentiation and classification of L. brevis with regard to their beer-spoiling ability is of vital interest for the brewing industry. Matrix-Assisted-Laser-Desorption-Ionization-Time-Of-Flight Mass Spectrometry (MALDI-TOF MS) has been shown as a powerful tool for species and sub-species differentiation of bacterial isolates and is increasingly used for strain-level differentiation. Seventeen L. brevis strains, representative of different spoilage types, were characterized according to their tolerance to iso-alpha-acids and their growth in wheat-, lager- and pilsner beer. MALDI-TOF MS spectra were acquired to perform strain-level identification, cluster analysis and biomarker detection. Strain-level identification was achieved in 90% out of 204 spectra. Misidentification occurred nearly exclusively among strains belonging to the same spoilage type. Though spectra of strongly beer-spoiling strains showed remarkable similarity, no decisive single markers were detected to be present in all strains of one group. However, MALDI-TOF MS spectra can be reliably assigned to the corresponding strain and thus allow to track single strains and connect them to their physiological properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Matrix-assisted laser desorption ionization-time of flight mass spectrometry based identification of Edwardsiella ictaluri isolated from Vietnamese striped catfish (Pangasius hypothalamus)

    Science.gov (United States)

    Nhu, Truong Quynh; Park, Seong Bin; Kim, Si Won; Lee, Jung Seok; Im, Se Pyeong; Lazarte, Jassy Mary S.; Seo, Jong Pyo; Lee, Woo-Jai; Kim, Jae Sung

    2016-01-01

    Edwardsiella (E.) ictaluri is a major bacterial pathogen that affects commercially farmed striped catfish (Pangasius hypothalamus) in Vietnam. In a previous study, 19 strains of E. ictaluri collected from striped catfish were biochemically identified with an API-20E system. Here, the same 19 strains were used to assess the ability of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS; applied using a MALDI Biotyper) to conduct rapid, easy and accurate identification of E. ictaluri. MALDI-TOF MS could directly detect the specific peptide patterns of cultured E. ictaluri colonies with high (> 2.0, indicating species-level identification) scores. MALDI Biotyper 3.0 software revealed that all of the strains examined in this study possessed highly similar peptide peak patterns. In addition, electrophoresis (SDS-PAGE) and subsequent immuno-blotting using a specific chicken antibody (IgY) against E. ictaluri revealed that the isolates had highly similar protein profiles and antigenic banding profiles. The results of this study suggest that E. ictaluri isolated from striped catfish in Vietnam have homologous protein compositions. This is important, because it indicates that MALDI-TOF MS analysis could potentially outperform the conventional methods of identifying E. ictaluri. PMID:26726022

  20. Novel approach for differentiating Shigella species and Escherichia coli by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Khot, Prasanna D; Fisher, Mark A

    2013-11-01

    Shigella species are so closely related to Escherichia coli that routine matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) cannot reliably differentiate them. Biochemical and serological methods are typically used to distinguish these species; however, "inactive" isolates of E. coli are biochemically very similar to Shigella species and thus pose a greater diagnostic challenge. We used ClinProTools (Bruker Daltonics) software to discover MALDI-TOF MS biomarker peaks and to generate classification models based on the genetic algorithm to differentiate between Shigella species and E. coli. Sixty-six Shigella spp. and 72 E. coli isolates were used to generate and test classification models, and the optimal models contained 15 biomarker peaks for genus-level classification and 12 peaks for species-level classification. We were able to identify 90% of E. coli and Shigella clinical isolates correctly to the species level. Only 3% of tested isolates were misidentified. This novel MALDI-TOF MS approach allows laboratories to streamline the identification of E. coli and Shigella species.

  1. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the rapid identification of yeasts causing bloodstream infections.

    Science.gov (United States)

    Ghosh, A K; Paul, S; Sood, P; Rudramurthy, S M; Rajbanshi, A; Jillwin, T J; Chakrabarti, A

    2015-04-01

    Few studies have systematically standardised and evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of yeasts from bloodstream infections. This is rapidly becoming pertinent for early identification of yeasts and appropriate antifungal therapy. We used 354 yeast strains identified by polymerase chain reaction (PCR) sequencing for standardisation and 367 blind clinical strains for validation of our MALDI-TOF MS protocols. We also evaluated different sample preparation methods and found the on-plate formic acid extraction method as most cost- and time-efficient. The MALDI-TOF assay correctly identified 98.9% of PCR-sequenced yeasts. Novel main spectrum projections (MSP) were developed for Candida auris, C. viswanathii and Kodamaea ohmeri, which were missing from the Bruker MALDI-TOF MS database. Spectral cut-offs computed by receiver operating characteristics (ROC) analysis showed 99.4% to 100% accuracy at a log score of ≥ 1.70 for C. tropicalis, C. parapsilosis, C. pelliculosa, C. orthopsilosis, C. albicans, C. rugosa, C. guilliermondii, C. lipolytica, C. metapsilosis, C. nivariensis. The differences in the species-specific scores of our standardisation and blind validation strains were not statistically significant, implying the optimal performance of our test protocol. The MSPs of the three new species also were validated. We conclude that MALDI-TOF MS is a rapid, accurate and reliable tool for identification of bloodstream yeasts. With proper standardisation, validation and regular database expansion, its efficiency can be further enhanced.

  2. Design and Performance of a Novel Interface for Combined Matrix-Assisted Laser Desorption Ionization at Elevated Pressure and Electrospray Ionization with Orbitrap Mass Spectrometry.

    Science.gov (United States)

    Belov, Mikhail E; Ellis, Shane R; Dilillo, Marialaura; Paine, Martin R L; Danielson, William F; Anderson, Gordon A; de Graaf, Erik L; Eijkel, Gert B; Heeren, Ron M A; McDonnell, Liam A

    2017-07-18

    Matrix-Assisted Laser Desorption Ionization, MALDI, has been increasingly used in a variety of biomedical applications, including tissue imaging of clinical tissue samples, and in drug discovery and development. These studies strongly depend on the performance of the analytical instrumentation and would drastically benefit from improved sensitivity, reproducibility, and mass/spatial resolution. In this work, we report on a novel combined MALDI/ESI interface, which was coupled to different Orbitrap mass spectrometers (Elite and Q Exactive Plus) and extensively characterized with peptide and protein standards, and in tissue imaging experiments. In our approach, MALDI is performed in the elevated pressure regime (5-8 Torr) at a spatial resolution of 15-30 μm, while ESI-generated ions are injected orthogonally to the interface axis. We have found that introduction of the MALDI-generated ions into an electrodynamic dual-funnel interface results in increased sensitivity characterized by a limit of detection of ∼400 zmol, while providing a mass measurement accuracy of 1 ppm and a mass resolving power of 120 000 in analysis of protein digests. In tissue imaging experiments, the MALDI/ESI interface has been employed in experiments with rat brain sections and was shown to be capable of visualizing and spatially characterizing very low abundance analytes separated only by 20 mDa. Comparison of imaging data has revealed excellent agreement between the MALDI and histological images.

  3. Characterization of Staphylococcus aureus Isolated from Clinical Specimens by Matrix Assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    WANG Ye Ru; CHEN Qian; CUI Sheng Hui; LI Feng Qin

    2013-01-01

    Objective To develop a matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) approach to identify Staphylococcus aureus (S. aureus) and differentiate methicillin-resistant S. aureus (MRSA) from methicillin-sensitive S. aureus (MSSA). Methods A total of 100 S. aureus strains isolated from clinical specimens and farm workers were collected and analyzed by MALDI-TOF-MS. And data obtained were interpreted with biotyper software. Results Ninety-two strains were identified by MALDI-TOF-MS as S. aureus at a level of secure genus and probable species, and 4 strains were identified at probable genus after their cultivation, spectral collection and data preprocessing. One strain was identified as S. aureus with lower score. It was revealed that identification of S. aureus by MALDI-TOF-MS was highly correlated with typing by biochemical and serological methods with an accuracy as high as 97%. The biotyper cluster analysis showed that 100 isolates were divided into 2 types at the distance level of 400. Higher peak intensity in the mass of both 3784 Da and 5700 Da was observed in MRSA, whereas that was absent from MSSA. Conclusion MALDI-TOF-MS is considered as a simple, rapid and highly reproducible technique with high-throughput and accuracy for the identification of S. aureus and it can reliably differentiate MRSA from MSSA.

  4. Flexible xxx-asp/asn and gly-xxx residues of equine cytochrome C in matrix-assisted laser desorption/ionization in-source decay mass spectrometry.

    Science.gov (United States)

    Takayama, Mitsuo

    2012-01-01

    The backbone flexibility of a protein has been studied from the standpoint of the susceptibility of amino acid residues to in-source decay (ISD) in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Residues more susceptible to MALDI-ISD, namely Xxx-Asp/Asn and Gly-Xxx, were identified from the discontinuous intense peak of c'-ions originating from specific cleavage at N-Cα bonds of the backbone of equine cytochrome c. The identity of the residues susceptible to ISD was consistent with the known flexible backbone amides as estimated by hydrogen/deuterium exchange (HDX) experiments. The identity of these flexible amino acid residues (Asp, Asn, and Gly) is consistent with the fact that these residues are preferred in flexible secondary structure free from intramolecular hydrogen-bonded structures such as α-helix and β-sheet. The MALDI-ISD spectrum of equine cytochrome c gave not only intense N-terminal side c'-ions originating from N-Cα bond cleavage at Xxx-Asp/Asn and Gly-Xxx residues, but also C-terminal side complement z'-ions originating from the same cleavage sites. The present study implies that MALDI-ISD can give information about backbone flexibility of proteins, comparable with the protection factors estimated by HDX.

  5. Rapid detection of high-risk Enterococcus faecium clones by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Freitas, Ana R; Sousa, Clara; Novais, Carla; Silva, Liliana; Ramos, Helena; Coque, Teresa M; Lopes, João; Peixe, Luísa

    2017-04-01

    We aimed to explore the potential of matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for early identification of dominant Enterococcus faecium (Efm) clones involved in human infections. Well-characterized Efm isolates (n=77), analyzed by pulsed-field gel electrophoresis and multilocus sequence typing(eBURST and BAPS [Bayesian analysis of population structure] algorithms), and belonging to different hospital (n=53) and community (n=24) phylogenomic groups, were tested. Mass spectra (Bruker) were analyzed by visual inspection and different chemometric tools. Discrimination between groups comprising isolates commonly found in hospitals (BAPS 2.1a, 3.3a1, 3.3a2) and community (BAPS 2.1b and 3.2) was achieved with >99% accuracy, while identification of sequence types belonging to different BAPS subgroups was associated with >95% correct predictions. Our work is a proof of concept with regard to the suitability of MALDI-TOF MS in the identification of high-risk Efm clones. Further studies including strains from a wider variety of clones and sources will strengthen the potential of the workflow here described.

  6. Localization of ginsenosides in Panax ginseng with different age by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry imaging.

    Science.gov (United States)

    Bai, Hangrui; Wang, Shujuan; Liu, Jianjun; Gao, Dan; Jiang, Yuyang; Liu, Hongxia; Cai, Zongwei

    2016-07-15

    The root of Panax ginseng C.A. Mey. (P. ginseng) is one of the most popular traditional Chinese medicines, with ginsenosides as its main bioactive components. Because different ginsenosides have varied pharmacological effects, extraction and separation of ginsenosides are usually required for the investigation of pharmacological effects of different ginsenosides. However, the contents of ginsenosides vary with the ages and tissues of P. ginseng root. In this research, an efficient method to explore the distribution of ginsenosides and differentiate P. ginseng roots with different ages was developed based on matrix assisted laser desorption/ionization time-of-flight mass spectrometry imaging (MALDI-TOF-MSI). After a simple sample preparation, there were 18 peaks corresponding to 31 ginsenosides with distinct localization in the mass range of m/z 700-1400 identified by MALDI-TOF-MSI and MALDI-TOF-MS/MS. All the three types of ginsenosides were successfully detected and visualized in images, which could be correlated with anatomical features. The P. ginseng at the ages of 2, 4 and 6 could be differentiated finely through the principal component analysis of data collected from the cork based on the ion images but not data from the whole tissue. The experimental result implies that the established method for the direct analysis of metabolites in plant tissues has high potential for the rapid identification of metabolites and analysis of their localizations in medicinal herbs. Furthermore, this technique also provides valuable information for the component-specific extraction and pharmacological research of herbs.

  7. Matrix-assisted laser desorption/ionization-time of flight-mass spectrometry profiling of trace constituents of condom lubricants in the presence of biological fluids.

    Science.gov (United States)

    Spencer, Sandra E; Kim, Sin Young; Kim, Seoung Bum; Schug, Kevin A

    2011-04-15

    The use of condoms in sexual assault cases has become increasingly common due to the heightened awareness of the use of DNA as evidence in criminal investigations. The ability to identify and differentiate the polymers and additives found in lubricant residues can provide investigators leads and insights as to the perpetrator of a sexual assault. Matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) is ideal for detecting condom lubricants and additives; the instrument is capable of surveying analytes across a wide mass range and is a preferred technique for the analysis of polymers. Three MALDI-TOF-MS methods directed toward the detection and differentiation of condom and personal lubricant residues, as well as their mixtures with biological fluids, were developed and compared: (a) a sample premixed with aqueous matrix; (b) a sample premixed with an ionic liquid matrix; and (c) a layering method that incorporates a cationization reagent. Of the three, the layered method that utilized sodium chloride as a cationization reagent showed the best sensitivity and selectivity. This method allowed for the segregation of the various lubricant formulas into a discrete number of groups. Infrared spectroscopy was used to support and clarify the MALDI data. Principal component analysis was used to further demonstrate the ability of this method to segregate various lubricant types into a limited number of classes. Additionally, lubricant residues could be detected in the presence of biological fluids down to a fraction of a percent.

  8. Classification algorithm for subspecies identification within the Mycobacterium abscessus species, based on matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Fangous, Marie-Sarah; Mougari, Faiza; Gouriou, Stéphanie; Calvez, Elodie; Raskine, Laurent; Cambau, Emmanuelle; Payan, Christopher; Héry-Arnaud, Geneviève

    2014-09-01

    Mycobacterium abscessus, as a species, has been increasingly implicated in respiratory infections, notably in cystic fibrosis patients. The species comprises 3 subspecies, which can be difficult to identify. Since they differ in antibiotic susceptibility and clinical relevance, developing a routine diagnostic tool discriminating Mycobacterium abscessus at the subspecies level is a real challenge. Forty-three Mycobacterium abscessus species isolates, previously identified by multilocus sequence typing, were analyzed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). A subspecies identification algorithm, based on five discriminating peaks, was drawn up and validated by blind identification of a further 49 strains, 94% of which (n = 46) were correctly identified. Two M. abscessus subsp. massiliense strains were misidentified as M. abscessus subsp. abscessus, and for 1 other strain identification failed. Inter- and intralaboratory reproducibility tests were conclusive. This study presents, for the first time, a classification algorithm for MALDI-TOF MS identification of the 3 M. abscessus subspecies. MALDI-TOF MS proved effective in discriminating within the M. abscessus species and might be easily integrated into the workflow of microbiology labs. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  9. Hydrophilic interaction chromatography coupled matrix assisted laser desorption/ionization mass spectrometry for molecular analysis of organic compounds in medicines, tea, and coffee

    KAUST Repository

    Wang, Renqi

    2013-01-01

    Natural occurring organic compounds from food, natural organic matter, as well as metabolic products have received intense attention in current chemical and biological studies. Examination of unknown compounds in complex sample matrices is hampered by the limited choices for data readout and molecular elucidation. Herein, we report a generic method of hydrophilic interaction chromatography (HILIC) coupled with matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the rapid characterization of ingredients in pharmaceutical compounds, tea, and coffee. The analytes were first fractionated using a cationic HILIC column prior to MALDI-MS analyses. It was found that the retention times of a compound arising from different samples were consistent under the same conditions. Accordingly, molecules can be readily characterized by both the mass and chromatographic retention time. The retention behaviors of acidic and basic compounds on the cationic HILIC column were found to be significantly influenced by the pH of mobile phases, whereas neutral compounds depicted a constant retention time at different pH. The general HILIC-MALDI-MS method is feasible for fast screening of naturally occurring organic compounds. A series of homologs can be determined if they have the same retention behavior. Their structural features can be elucidated by considering their mass differences and hydrophilic properties as determined by HILIC chromatogram. © 2013 The Royal Society of Chemistry.

  10. Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid

    Directory of Open Access Journals (Sweden)

    Gomez-Mancilla Baltazar

    2006-04-01

    Full Text Available Abstract Cerebrospinal fluid (CSF potentially carries an archive of peptides and small proteins relevant to pathological processes in the central nervous system (CNS and surrounding brain tissue. Proteomics is especially well suited for the discovery of biomarkers of diagnostic potential in CSF for early diagnosis and discrimination of several neurodegenerative diseases. ProteinChip surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS is one such approach which offers a unique platform for high throughput profiling of peptides and small proteins in CSF. In this study, we evaluated methodologies for the retention of CSF proteins m/z we found a high degree of overlap between the tested array surfaces. The combination of CM10 and IMAC30 arrays was sufficient to represent between 80–90% of all assigned peaks when using either sinapinic acid or α-Cyano-4-hydroxycinnamic acid as the energy absorbing matrices. Moreover, arrays processed with SPA consistently showed better peak resolution and higher peak number across all surfaces within the measured mass range. We intend to use CM10 and IMAC30 arrays prepared in sinapinic acid as a fast and cost-effective approach to drive decisions on sample selection prior to more in-depth discovery of diagnostic biomarkers in CSF using alternative but complementary proteomic strategies.

  11. Identification of pathogenic microorganisms directly from positive blood vials by matrix-assisted laser desorption/ionization time of flight mass spectrometry

    DEFF Research Database (Denmark)

    Nonnemann, Bettina; Tvede, Michael; Bjarnsholt, Thomas

    2013-01-01

    Matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) is a promising and fast method for identifying fungi and bacteria directly from positive blood cultures. Various pre-treatment methods for MALDI-TOF MS identification have been reported for this purpose. In......-house results for identification of bacterial colonies by MALDI-TOF MS using a cut-off score of 1.5 did not reduce the diagnostic accuracy compared with the recommended cut-off score of 1.8. A 3-month consecutive study of positive blood cultures was carried out in our laboratory to evaluate whether...... the Sepsityper™ Kit (Bruker Daltonics) with Biotyper 2.0 software could be used as a fast diagnostic tool for bacteria and fungi and whether a 1.5 cut-off score could improve species identification compared with the recommended score of 1.8. Two hundred and fifty-six positive blood vials from 210 patients and 19...

  12. [The research and application of pretreatment method for matrix-assisted laser desorption ionization-time of flight mass spectrometry identification of filamentous fungi].

    Science.gov (United States)

    Huang, Y F; Chang, Z; Bai, J; Zhu, M; Zhang, M X; Wang, M; Zhang, G; Li, X Y; Tong, Y G; Wang, J L; Lu, X X

    2017-08-08

    Objective: To establish and evaluate the feasibility of a pretreatment method for matrix-assisted laser desorption ionization-time of flight mass spectrometry identification of filamentous fungi developed by the laboratory. Methods: Three hundred and eighty strains of filamentous fungi from January 2014 to December 2016 were recovered and cultured on sabouraud dextrose agar (SDA) plate at 28 ℃ to mature state. Meanwhile, the fungi were cultured in liquid sabouraud medium with a vertical rotation method recommended by Bruker and a horizontal vibration method developed by the laboratory until adequate amount of colonies were observed. For the strains cultured with the three methods, protein was extracted with modified magnetic bead-based extraction method for mass spectrum identification. Results: For 380 fungi strains, it took 3-10 d to culture with SDA culture method, and the ratio of identification of the species and genus was 47% and 81%, respectively; it took 5-7 d to culture with vertical rotation method, and the ratio of identification of the species and genus was 76% and 94%, respectively; it took 1-2 d to culture with horizontal vibration method, and the ratio of identification of the species and genus was 96% and 99%, respectively. For the comparison between horizontal vibration method and SDA culture method comparison, the difference was statistically significant (χ(2)=39.026, Pfilamentous fungi, which can be applied in clinic.

  13. Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry: a Fundamental Shift in the Routine Practice of Clinical Microbiology

    Science.gov (United States)

    Clark, Andrew E.; Kaleta, Erin J.; Arora, Amit

    2013-01-01

    SUMMARY Within the past decade, clinical microbiology laboratories experienced revolutionary changes in the way in which microorganisms are identified, moving away from slow, traditional microbial identification algorithms toward rapid molecular methods and mass spectrometry (MS). Historically, MS was clinically utilized as a high-complexity method adapted for protein-centered analysis of samples in chemistry and hematology laboratories. Today, matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS is adapted for use in microbiology laboratories, where it serves as a paradigm-shifting, rapid, and robust method for accurate microbial identification. Multiple instrument platforms, marketed by well-established manufacturers, are beginning to displace automated phenotypic identification instruments and in some cases genetic sequence-based identification practices. This review summarizes the current position of MALDI-TOF MS in clinical research and in diagnostic clinical microbiology laboratories and serves as a primer to examine the “nuts and bolts” of MALDI-TOF MS, highlighting research associated with sample preparation, spectral analysis, and accuracy. Currently available MALDI-TOF MS hardware and software platforms that support the use of MALDI-TOF with direct and precultured specimens and integration of the technology into the laboratory workflow are also discussed. Finally, this review closes with a prospective view of the future of MALDI-TOF MS in the clinical microbiology laboratory to accelerate diagnosis and microbial identification to improve patient care. PMID:23824373

  14. Matrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology.

    Science.gov (United States)

    Clark, Andrew E; Kaleta, Erin J; Arora, Amit; Wolk, Donna M

    2013-07-01

    Within the past decade, clinical microbiology laboratories experienced revolutionary changes in the way in which microorganisms are identified, moving away from slow, traditional microbial identification algorithms toward rapid molecular methods and mass spectrometry (MS). Historically, MS was clinically utilized as a high-complexity method adapted for protein-centered analysis of samples in chemistry and hematology laboratories. Today, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS is adapted for use in microbiology laboratories, where it serves as a paradigm-shifting, rapid, and robust method for accurate microbial identification. Multiple instrument platforms, marketed by well-established manufacturers, are beginning to displace automated phenotypic identification instruments and in some cases genetic sequence-based identification practices. This review summarizes the current position of MALDI-TOF MS in clinical research and in diagnostic clinical microbiology laboratories and serves as a primer to examine the "nuts and bolts" of MALDI-TOF MS, highlighting research associated with sample preparation, spectral analysis, and accuracy. Currently available MALDI-TOF MS hardware and software platforms that support the use of MALDI-TOF with direct and precultured specimens and integration of the technology into the laboratory workflow are also discussed. Finally, this review closes with a prospective view of the future of MALDI-TOF MS in the clinical microbiology laboratory to accelerate diagnosis and microbial identification to improve patient care.

  15. Subtype determination of Blastocystis isolates by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Martiny, D; Bart, A; Vandenberg, O; Verhaar, N; Wentink-Bonnema, E; Moens, C; van Gool, T

    2014-04-01

    The pathogenic role of the enteric parasite Blastocystis remains controversial. Recent studies have suggested that various subtypes (STs) found in human samples could be correlated to the presence or absence and variability of clinical manifestations, and that STs can differ with respect to drug sensitivity. Polymerase chain reaction (PCR) techniques used to determine these STs are expensive and are usually restricted to research laboratory settings. This study evaluates the potential application of the inexpensive matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) technique to discriminate Blastocystis STs. A database of parasitic protein signatures was constructed for five Blastocystis STs, and the reference spectra were challenged with those from 19 axenic cultures of ST1, ST2, ST3, ST4 and ST8 and those from nine xenic liquid cultures of ST3 and ST4. Samples from axenic cultures were prepared using standard formic acid extraction and direct deposition procedures. The reference spectra revealed five distinct spectral profiles, and the database library allowed for discrimination between all of the cultures with reliability indices ranging from 2.038 to greater than 2.8 when an extraction was performed. The direct deposition procedure resulted in greater variability in the discrimination and direct MALDI-TOF MS identification from xenic liquid cultures was effective in 3 out of 9 samples. MALDI-TOF MS proved to be an effective technology for efficiently discriminating Blastocystis STs in axenic cultures.

  16. Gold nanoparticles bridging infra-red spectroscopy and laser desorption/ionization mass spectrometry for direct analysis of over-the-counter drug and botanical medicines.

    Science.gov (United States)

    Chau, Siu-Leung; Tang, Ho-Wai; Ng, Kwan-Ming

    2016-05-05

    With a coating of gold nanoparticles (AuNPs), over-the-counter (OTC) drugs and Chinese herbal medicine granules in KBr pellets could be analyzed by Fourier Transform Infra-red (FT-IR) spectroscopy and Surface-assisted Laser Desorption/Ionization mass spectrometry (SALDI-MS). FT-IR spectroscopy allows fast detection of major active ingredient (e.g., acetaminophen) in OTC drugs in KBr pellets. Upon coating a thin layer of AuNPs on the KBr pellet, minor active ingredients (e.g., noscapine and loratadine) in OTC drugs, which were not revealed by FT-IR, could be detected unambiguously using AuNPs-assisted LDI-MS. Moreover, phytochemical markers of Coptidis Rhizoma (i.e. berberine, palmatine and coptisine) could be quantified in the concentrated Chinese medicine (CCM) granules by the SALDI-MS using standard addition method. The quantitative results matched with those determined by high-performance liquid chromatography with ultraviolet detection. Being strongly absorbing in UV yet transparent to IR, AuNPs successfully bridged FT-IR and SALDI-MS for direct analysis of active ingredients in the same solid sample. FT-IR allowed the fast analysis of major active ingredient in drugs, while SALDI-MS allowed the detection of minor active ingredient in the presence of excipient, and also quantitation of phytochemicals in herbal granules. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Evaluation of synthase and hemisynthase activities of glucosamine-6-phosphate synthase by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Gaucher-Wieczorek, Florence; Guérineau, Vincent; Touboul, David; Thétiot-Laurent, Sophie; Pelissier, Franck; Badet-Denisot, Marie-Ange; Badet, Bernard; Durand, Philippe

    2014-08-01

    Glucosamine-6-phosphate synthase (GlmS, EC 2.6.1.16) catalyzes the first and rate-limiting step in the hexosamine biosynthetic pathway, leading to the synthesis of uridine-5'-diphospho-N-acetyl-D-glucosamine, the major building block for the edification of peptidoglycan in bacteria, chitin in fungi, and glycoproteins in mammals. This bisubstrate enzyme converts D-fructose-6-phosphate (Fru-6P) and L-glutamine (Gln) into D-glucosamine-6-phosphate (GlcN-6P) and L-glutamate (Glu), respectively. We previously demonstrated that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) allows determination of the kinetic parameters of the synthase activity. We propose here to refine the experimental protocol to quantify Glu and GlcN-6P, allowing determination of both hemisynthase and synthase parameters from a single assay kinetic experiment, while avoiding interferences encountered in other assays. It is the first time that MALDI-MS is used to survey the activity of a bisubstrate enzyme.

  18. Study of Phospholipids in Single Cells Using an Integrated Microfluidic Device Combined with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

    Science.gov (United States)

    Xie, Weiyi; Gao, Dan; Jin, Feng; Jiang, Yuyang; Liu, Hongxia

    2015-07-21

    Single-cell trapping and high-throughput mass spectrometry analysis remain challenging now. Current technologies for single-cell analysis have several limitations, such as throughput, space resolution, and multicomponent analysis. In this study, we demonstrate, for the first time, the combination of microfluidic chip and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for high-throughput and automatic single-cell phospholipids analysis. A microwell-array-based microfluidic chip was designed and fabricated for cell array formation on an indium tin oxide (ITO)-coated glass slide. Mass spectrometry imaging measurement with 25 μm pixel size was performed with a MALDI ion source. Eight phospholipids in a single A549 cell were detected, and their structures were further identified by MS/MS spectra. Selected ion images were generated with a bin width of Δm/z ± 0.005. The selected ion images and optical images of the cell array showed excellent correlation, and mass spectrometry information on phospholipids from 1-3 cells was extracted automatically by selecting pixels with the same fixed interval between microwells on the chip. The measurement and data extraction could be processed in several minutes to achieve a high-throughput analysis. Through the optimization of different microwell sizes and different matrices, this method showed potential for the analysis of other metabolites or metabolic changes at the single-cell level.

  19. Increased detection rate of melamine-containing calcium urolithiasis by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique in clinical practice.

    Science.gov (United States)

    Wu, Chia-Fang; Liu, Chia-Chu; Chou, Yii-Her; Shiea, Jentaie; Shen, Jung-Tsung; Wang, Shiun-Shiuan; Wu, Ming-Tsang

    2014-04-20

    Background: Studies have shown that melamine may be associated with urolithiasis. A more sensitive method is needed to analyze melamine in urinary stones to identify potential causes of urolithiasis.Methods: Here we compare the analytical methods of detecting melamine in urinary stones by Fourier transform infrared (FTIR) spectroscopy and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS) in the laboratory and clinic. First, we established the melamine detection limit in melamine cyanurate standard by the methods of FTIR spectrophotometer and MALDI-TOF MS. Subsequently, we applied these two methods to 54 adult patients with upper urinary tract calcium urolithiasis.Results: We found that the detection limit of melamine in melamine cyanurate standard by MALD-TOF MS was~10,000-fold more sensitive than FTIR.We applied both instruments to 54 stone specimens from 54 calcium urolithias is patients. In those without distinctive melamine pattern in the FTIR spectra,melamine could be detected by MALD-TOF MS in an additional 12 out of 42 subjects' stone specimens (28.6%). Compared to MALD-TOF MS negative subjects (n = 30), those positive subjects (n = 12) excreted significantly higher urinary melamine levels (P melamine in melamine-containing kidney stones

  20. Monitoring the enzymatic polymerization of 4-phenylphenol by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a novel approach.

    Science.gov (United States)

    Xu, Peng; Kumar, Jayant; Samuelson, Lynne; Cholli, Ashok L

    2002-01-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry is a powerful tool for polymer characterization. It has been used to understand the enzymatic polymerization of 4-phenylphenol and to monitor number average molecular weight and weight average molecular weight of the polymer as a function of systematic addition of hydrogen peroxide (H(2)O(2)) in the reaction. A novel method, an introduction of internal standard for quantification of data, has been developed for MALDI-TOF MS to investigate the fate of each mers during the reaction. The preliminary data suggest that this approach provides new insight on the enzymatic synthesis, which is not available by other techniques. For the first time, we are able to understand the fate of several mers as a function of reaction conditions. The relative content of each mer increases with the addition of H(2)O(2), except for dimer and trimer. For example, the concentration of dimer species decreases as a function of H(2)O(2). On the other hand, the concentration of trimer species increases first and then decreases in the course of the reaction.

  1. Gold-decorated titania nanotube arrays as dual-functional platform for surface-enhanced Raman spectroscopy and surface-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Nitta, Syuhei; Yamamoto, Atsushi; Kurita, Masahiro; Arakawa, Ryuichi; Kawasaki, Hideya

    2014-06-11

    In this report, we demonstrate gold-decorated titania nanotube arrays (Au-TNA substrate) as a dual-functional platform for surface-enhanced Raman spectroscopy (SERS) and surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS). The Au nanoparticles are grown on the substrate using vapor deposition of Au. The resulting substrates perform better than Au colloids in terms of the reproducibility of the SERS measurements, long-term stability of the fabricated structures, and clean surface of the Au. The nanostructure of the Au-TNA substrate was designed to optimize the SALDI-MS and SERS performance. Excellent reproducibility of the SERS measurements using the Au-TNA substrate was obtained, with a standard error less than 6 %. SALDI activity was also demonstrated for the same Au-TNA substrates. Finally, the Au-TNA substrate was used for combined SERS and SALDI-MS analysis (i) to discriminate the structural isomers of pyridine compounds (para-, meta-, and ortho-pyridinecarboxylic acid) and (ii) to detect polycarbamate, a dithiocarbamate fungicide. These results are difficult to obtain using either approach alone.

  2. Accuracy of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of clinical pathogenic fungi: a meta-analysis.

    Science.gov (United States)

    Ling, Huazhi; Yuan, Zhijie; Shen, Jilu; Wang, Zhongxin; Xu, Yuanhong

    2014-07-01

    Fungal infections in the clinic have become increasingly serious. In many cases, the identification of clinically relevant fungi remains time-consuming and may also be unreliable. Matrix-assisted laser desorption ionization-time of flight mass spectroscopy (MALDI-TOF MS) is a newly developed diagnostic tool that is increasingly being employed to rapidly and accurately identify clinical pathogenic microorganisms. The present meta-analysis aimed to systematically evaluate the accuracy of MALDI-TOF MS for the identification of clinical pathogenic fungi. After a rigorous selection process, 33 articles, involving 38 trials and a total of 9,977 fungal isolates, were included in the meta-analysis. The random-effects pooled identification accuracy of MALDI-TOF MS increased from 0.955 (95% confidence interval [CI], 0.939 to 0.969) at the species level to 0.977 (95% CI, 0.955 to 0.993) at the genus level (P meta-analysis and some of the subanalyses. In parallel, significant differences in heterogeneity among different systems and among different methods for calculating the identification ratios were found by multivariate metaregression, but none of the factors, except for the moderator of outcome, was significantly associated with heterogeneity by univariate metaregression. In summary, the MALDI-TOF MS method is highly accurate for the identification of clinically pathogenic fungi; future studies should analyze the comprehensive capability of this technology for clinical diagnostic microbiology.

  3. Decision peptide-driven: a free software tool for accurate protein quantification using gel electrophoresis and matrix assisted laser desorption ionization time of flight mass spectrometry.

    Science.gov (United States)

    Santos, Hugo M; Reboiro-Jato, Miguel; Glez-Peña, Daniel; Nunes-Miranda, J D; Fdez-Riverola, Florentino; Carvallo, R; Capelo, J L

    2010-09-15

    The decision peptide-driven tool implements a software application for assisting the user in a protocol for accurate protein quantification based on the following steps: (1) protein separation through gel electrophoresis; (2) in-gel protein digestion; (3) direct and inverse (18)O-labeling and (4) matrix assisted laser desorption ionization time of flight mass spectrometry, MALDI analysis. The DPD software compares the MALDI results of the direct and inverse (18)O-labeling experiments and quickly identifies those peptides with paralleled loses in different sets of a typical proteomic workflow. Those peptides are used for subsequent accurate protein quantification. The interpretation of the MALDI data from direct and inverse labeling experiments is time-consuming requiring a significant amount of time to do all comparisons manually. The DPD software shortens and simplifies the searching of the peptides that must be used for quantification from a week to just some minutes. To do so, it takes as input several MALDI spectra and aids the researcher in an automatic mode (i) to compare data from direct and inverse (18)O-labeling experiments, calculating the corresponding ratios to determine those peptides with paralleled losses throughout different sets of experiments; and (ii) allow to use those peptides as internal standards for subsequent accurate protein quantification using (18)O-labeling. In this work the DPD software is presented and explained with the quantification of protein carbonic anhydrase.

  4. Dithranol as a matrix for matrix assisted laser desorption/ionization imaging on a fourier transform ion cyclotron resonance mass spectrometer.

    Science.gov (United States)

    Le, Cuong H; Han, Jun; Borchers, Christoph H

    2013-11-26

    Mass spectrometry imaging (MSI) determines the spatial localization and distribution patterns of compounds on the surface of a tissue section, mainly using MALDI (matrix assisted laser desorption/ionization)-based analytical techniques. New matrices for small-molecule MSI, which can improve the analysis of low-molecular weight (MW) compounds, are needed. These matrices should provide increased analyte signals while decreasing MALDI background signals. In addition, the use of ultrahigh-resolution instruments, such as Fourier transform ion cyclotron resonance (FTICR) mass spectrometers, has the ability to resolve analyte signals from matrix signals, and this can partially overcome many problems associated with the background originating from the MALDI matrix. The reduction in the intensities of the metastable matrix clusters by FTICR MS can also help to overcome some of the interferences associated with matrix peaks on other instruments. High-resolution instruments such as the FTICR mass spectrometers are advantageous as they can produce distribution patterns of many compounds simultaneously while still providing confidence in chemical identifications. Dithranol (DT; 1,8-dihydroxy-9,10-dihydroanthracen-9-one) has previously been reported as a MALDI matrix for tissue imaging. In this work, a protocol for the use of DT for MALDI imaging of endogenous lipids from the surfaces of mammalian tissue sections, by positive-ion MALDI-MS, on an ultrahigh-resolution hybrid quadrupole FTICR instrument has been provided.

  5. Application of surface-enhanced laser desorption/ionization time-of-flight-based serum proteomic array technique for the early diagnosis of prostate cancer

    Institute of Scientific and Technical Information of China (English)

    Yu-Zhuo Pan; Xue-Yuan Xiao; Dan Zhao; Ling Zhang; Guo-Yi Ji; Yang Li; Bao-Xue Yang; Da-Cheng He; Xue-Jian Zhao

    2006-01-01

    Aim: To identify the serum biomarkers of prostate cancer (PCa) by protein chip and bioinformatics. Methods:Serum samples from 83 PCa patients and 95 healthy men were taken from a mass screening in Changchun, China.Protein profiling was carried out using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS). The data of spectra were analyzed using two bioinformatics tools. Results: Eighteen serum differential proteins were identified in the PCa group compared with the control group (P < 0.01). There were four proteins at the higher serum level and 14 proteins at the lower serum level in the PCa group. A decision tree classification algorithm that used an eight-protein mass pattern was developed to correctly classify the samples. A sensitivity of 92.0 % and a specificity of 96.7 % for the study group were obtained by comparing the PCa and control groups.Conclusion: We identified new serum biomarkers of PCa. SELDI-TOF MS coupled with a decision tree classification algorithm will provide a highly accurate and innovative approach for the early diagnosis of PCa.

  6. Investigations of the lysophospholipid composition of human neutrophils under different stimulation conditions by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    Directory of Open Access Journals (Sweden)

    JURGEN ARNHOLD

    2002-03-01

    Full Text Available Matrix-assisted laser desorption / ionization time-of-flight mass spectrometry (MALDI-TOF MS is usually used for the analyses of proteins, carbohydrates and oligonucleotides. In spite of the number of advantages that MALDI-TOF MS exhibits for lipid analysis, this method has not often been applied in this field. In this paper we have extended our previous studies on the suitability of MALDI-TOF MS for the investigation of changes in the content of lipid-derived second messengers in organic extracts of human neutrophils. Qualitative differences in the lysophospholipid composition in organic extracts of the human neutrophils under different stimulation conditions could be easily observed by MALDI-TOF MS. Although there are still some methodological problems to be solved before this method can be routinely applied for the quantification of different lipid classes in complex biological mixtures (such as organic extracts of human neutrophils it is shown here that MALDI-TOF MS possesses the capability to be used as a simple screening method for the investigation of the content of lipid-derived second messengers and of signalling pathways in cells.

  7. Visualization of phosphatidylcholine, lysophosphatidylcholine and sphingomyelin in mouse tongue body by matrix-assisted laser desorption/ionization imaging mass spectrometry.

    Science.gov (United States)

    Enomoto, Hirofumi; Sugiura, Yuki; Setou, Mitsutoshi; Zaima, Nobuhiro

    2011-06-01

    The mammalian tongue is one of the most important organs during food uptake because it is helpful for mastication and swallowing. In addition, taste receptors are present on the surface of the tongue. Lipids are the second most abundant biomolecules after water in the tongue. Lipids such as phosphatidylcholine (PC), lysophosphatidylcholine (LPC) and sphingomyelin (SM) are considered to play fundamental roles in the mediation of cell signaling. Imaging mass spectrometry (IMS) is powerful tool for determining and visualizing the distribution of lipids across sections of dissected tissue. In this study, we identified and visualized the PC, LPC, and SM species in a mouse tongue body section with matrix-assisted laser desorption/ionization (MALDI)-IMS. The ion image constructed from the peaks revealed that docosahexaenoic acid (DHA)-containing PC, LPC, linoleic acid-containing PC and SM (d18:1/16:0), and oleic acid-containing PC were mainly distributed in muscle, connective tissue, stratified epithelium, and the peripheral nerve, respectively. Furthermore, the distribution of SM (d18:1/16:0) corresponded to the distribution of nerve tissue relating to taste in the stratified epithelium. This study represents the first visualization of PC, LPC and SM localization in the mouse tongue body.

  8. Matrix-assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) Can Precisely Discriminate the Lineages of Listeria monocytogenes and Species of Listeria.

    Science.gov (United States)

    Ojima-Kato, Teruyo; Yamamoto, Naomi; Takahashi, Hajime; Tamura, Hiroto

    2016-01-01

    The genetic lineages of Listeria monocytogenes and other species of the genus Listeria are correlated with pathogenesis in humans. Although matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has become a prevailing tool for rapid and reliable microbial identification, the precise discrimination of Listeria species and lineages remains a crucial issue in clinical settings and for food safety. In this study, we constructed an accurate and reliable MS database to discriminate the lineages of L. monocytogenes and the species of Listeria (L. monocytogenes, L. innocua, L. welshimeri, L. seeligeri, L. ivanovii, L. grayi, and L. rocourtiae) based on the S10-spc-alpha operon gene encoded ribosomal protein mass spectrum (S10-GERMS) proteotyping method, which relies on both genetic information (genomics) and observed MS peaks in MALDI-TOF MS (proteomics). The specific set of eight biomarkers (ribosomal proteins L24, L6, L18, L15, S11, S9, L31 type B, and S16) yielded characteristic MS patterns for the lineages of L. monocytogenes and the different species of Listeria, and led to the construction of a MS database that was successful in discriminating between these organisms in MALDI-TOF MS fingerprinting analysis followed by advanced proteotyping software Strain Solution analysis. We also confirmed the constructed database on the proteotyping software Strain Solution by using 23 Listeria strains collected from natural sources.

  9. Direct identification of trypanosomatids by matrix-assisted laser desorption ionization-time of flight mass spectrometry (DIT MALDI-TOF MS).

    Science.gov (United States)

    Avila, C C; Almeida, F G; Palmisano, G

    2016-08-01

    Accurate and rapid determination of trypanosomatids is essential in epidemiological surveillance and therapeutic studies. Matrix-assisted laser desorption ionization/time of flight mass spectrometry (MALDI-TOF MS) has been shown to be a useful and powerful technique to identify bacteria, fungi, metazoa and human intact cells with applications in clinical settings. Here, we developed and optimized a MALDI-TOF MS method to profile trypanosomatids. trypanosomatid cells were deposited on a MALDI target plate followed by addition of matrix solution. The plate was then subjected to MALDI-TOF MS measurement to create reference mass spectra library and unknown samples were identified by pattern matching using the BioTyper software tool. Several m/z peaks reproducibly and uniquely identified trypanosomatids species showing the potentials of direct identification of trypanosomatids by MALDI-TOF MS. Moreover, this method discriminated different life stages of Trypanosoma cruzi, epimastigote and bloodstream trypomastigote and Trypanosoma brucei, procyclic and bloodstream. T. cruzi Discrete Typing Units (DTUs) were also discriminated in three clades. However, it was not possible to achieve enough resolution and software-assisted identification at the strain level. Overall, this study shows the importance of MALDI-TOF MS for the direct identification of trypanosomatids and opens new avenues for mass spectrometry-based detection of parasites in biofluids. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Solvent selection for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis of synthetic polymers employing solubility parameters.

    Science.gov (United States)

    Brandt, Heike; Ehmann, Thomas; Otto, Matthias

    2010-08-30

    The principle relating to the selection of a proper matrix, cationization reagent, and solvent for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) of synthetic polymers is still a topic of research. In this work we focused on the selection of a suitable MALDI solvent. Polystyrene PS7600 and poly(ethylene glycol) PEG4820 were analyzed by MALDI-TOF MS using various solvents which were selected based on the Hansen solubility parameter system. For polystyrene (PS), dithranol was used as the matrix and silver trifluoroacetate as the cationization reagent whereas, for poly(ethylene glycol) (PEG), the combination of 2,5-dihydroxybenzoic acid and sodium trifluoroacetate was used for all experiments. When employing solvents which dissolve PS and PEG, reliable MALDI mass spectra were obtained while samples in non-solvents (solvents which are not able to dissolve the polymer) failed to provide spectra. It seems that the solubility of the matrix and the cationization reagent are less important than the polymer solubility.

  11. Direct Analysis of hCGβcf Glycosylation in Normal and Aberrant Pregnancy by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ray K. Iles

    2014-06-01

    Full Text Available The analysis of human chorionic gonadotropin (hCG in clinical chemistry laboratories by specific immunoassay is well established. However, changes in glycosylation are not as easily assayed and yet alterations in hCG glycosylation is associated with abnormal pregnancy. hCGβ-core fragment (hCGβcf was isolated from the urine of women, pregnant with normal, molar and hyperemesis gravidarum pregnancies. Each sample was subjected to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS analysis following dithiothreitol (DTT reduction and fingerprint spectra of peptide hCGβ 6–40 were analyzed. Samples were variably glycosylated, where most structures were small, core and largely mono-antennary. Larger single bi-antennary and mixtures of larger mono-antennary and bi-antennary moieties were also observed in some samples. Larger glycoforms were more abundant in the abnormal pregnancies and tri-antennary carbohydrate moieties were only observed in the samples from molar and hyperemesis gravidarum pregnancies. Given that such spectral profiling differences may be characteristic, development of small sample preparation for mass spectral analysis of hCG may lead to a simpler and faster approach to glycostructural analysis and potentially a novel clinical diagnostic test.

  12. Peptidylation for the determination of low-molecular-weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Tang, Feng; Cen, Si-Ying; He, Huan; Liu, Yi; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-05-23

    Determination of low-molecular-weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been a great challenge in the analytical research field. Here we developed a universal peptide-based derivatization (peptidylation) strategy for the sensitive analysis of low-molecular-weight compounds by MALDI-TOF-MS. Upon peptidylation, the molecular weights of target analytes increase, thus avoiding serious matrix ion interference in the low-molecular-weight region in MALDI-TOF-MS. Since peptides typically exhibit good signal response during MALDI-TOF-MS analysis, peptidylation endows high detection sensitivities of low-molecular-weight analytes. As a proof-of-concept, we analyzed low-molecular-weight compounds of aldehydes and thiols by the developed peptidylation strategy. Our results showed that aldehydes and thiols can be readily determined upon peptidylation, thus realizing the sensitive and efficient determination of low-molecular-weight compounds by MALDI-TOF-MS. Moreover, target analytes also can be unambiguously detected in biological samples using the peptidylation strategy. The established peptidylation strategy is a universal strategy and can be extended to the sensitive analysis of various low-molecular-weight compounds by MALDI-TOF-MS, which may be potentially used in areas such as metabolomics.

  13. Cultivable Methylobacterium species diversity in rice seeds identified with whole-cell matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis.

    Science.gov (United States)

    Okumura, Marie; Fujitani, Yoshiko; Maekawa, Masahiko; Charoenpanich, Jittima; Murage, Hunja; Kimbara, Kazuhide; Sahin, Nurettin; Tani, Akio

    2017-02-01

    Methylobacterium species are methylotrophic bacteria that widely inhabit plant surfaces. In addition to studies on methylotrophs as model organisms, research has also been conducted on their mechanism of plant growth promotion as well as the species-species specificity of plant-microbe interaction. We employed whole-cell matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (WC-MS) analysis, which enables the rapid and accurate identification of bacteria at the species level, to identify Methylobacterium isolates collected from the rice seeds of different cultivars harvested in Japan, Thailand, and Kenya. Rice seeds obtained from diverse geographical locations showed different communities of Methylobacterium species. We found that M. fujisawaense, M. aquaticum, M. platani, and M. radiotolerans are the most frequently isolated species, but none were isolated as common species from 18 seed samples due to the highly biased communities in some samples. These findings will contribute to the development of formulations containing selected species that promote rice growth, though it may be necessary to customize the formulations depending on the cultivars and farm conditions.

  14. Comparing inactivation protocols of Yersinia organisms for identification with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Couderc, Carine; Nappez, Claude; Drancourt, Michel

    2012-03-30

    It is recommended that harmful Biosafety Level 3 (BSL-3) bacteria be inactivated prior to identification by mass spectrometry, yet optimal effects of inactivation protocol have not been defined. Here, we compare trifluoroacetic acid inactivation (protocol A) with ethanol inactivation (protocol B) of Yersinia organisms prior to identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The total number of peaks detected was 10.5 ± 1.7 for protocol A and 15.7 ± 4.2 for protocol B (ρ Yersinia isolates was 9.7 ± 3.1 for protocol A and 18.1 ± 4.6 for protocol B (ρ Yersinia spp., including 20 strains of Y. pestis, the identification score was 1.79 ± 0.2 for protocol A and 1.97 ± 0.19 for protocol B (ρ = 0.0024). Our observations indicate that for the identification of Yersinia organisms, ethanol inactivation yielded MALDI-TOF-MS spectra of significantly higher quality than spectra derived from trifluoroacetic acid inactivation. Combined with previously published data, our results permit the updating of protocols for inactivating BSL-3 bacteria. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Carbamazepine in municipal wastewater and wastewater sludge: ultrafast quantification by laser diode thermal desorption-atmospheric pressure chemical ionization coupled with tandem mass spectrometry.

    Science.gov (United States)

    Mohapatra, D P; Brar, S K; Tyagi, R D; Picard, P; Surampalli, R Y

    2012-09-15

    In this study, the distribution of the anti-epileptic drug carbamazepine (CBZ) in wastewater (WW) and aqueous and solid phases of wastewater sludge (WWS) was carried out. A rapid and reliable method enabling high-throughput sample analysis for quicker data generation, detection, and monitoring of CBZ in WW and WWS was developed and validated. The ultrafast method (15s per sample) is based on the laser diode thermal desorption-atmospheric pressure chemical ionization (LDTD-APCI) coupled to tandem mass spectrometry (MS/MS). The optimization of instrumental parameters and method application for environmental analysis are presented. The performance of the novel method was evaluated by estimation of extraction recovery, linearity, precision and detection limit. The method detection limits was 12 ng L(-1) in WW and 3.4 ng g(-1) in WWS. The intra- and inter-day precisions were 8% and 11% in WW and 6% and 9% in WWS, respectively. Furthermore, three extraction methods, ultrasonic extraction (USE), microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) with three different solvent condition such as methanol, acetone and acetonitrile:ethyle acetate (5:1, v/v) were compared on the basis of procedural blank and method recovery. Overall, ASE showed the best extraction efficiency with methanol as compared to USE and MAE. Furthermore, the quantification of CBZ in WW and WWS samples showed the presence of contaminant in all stages of the treatment plant.

  16. Enhanced visualization of small peptides absorbed in rat small intestine by phytic-acid-aided matrix-assisted laser desorption/ionization-imaging mass spectrometry.

    Science.gov (United States)

    Hong, Seong-Min; Tanaka, Mitsuru; Yoshii, Saori; Mine, Yoshinori; Matsui, Toshiro

    2013-11-05

    Enhanced visualization of small peptides absorbed through a rat intestinal membrane was achieved by matrix-assisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-IMS) with the aid of phytic acid as a matrix additive. Penetrants through intestinal peptide transporter 1, i.e., glycyl-sarcosine (Gly-Sar, 147.1 m/z) and antihypertensive dipeptide, Val-Tyr (281.2 m/z), were chosen for MALDI-IMS. The signal-to-noise (S/N) ratios of dipeptides Gly-Sar and Val-Tyr were seen to increase by 2.4- and 8.0-fold, respectively, when using a 2',4',6'-trihydroxyacetophenone (THAP) matrix containing 5.0 mM phytic acid, instead of the THAP matrix alone. Owing to the phytic-acid-aided MALDI-IMS method, Gly-Sar and Val-Tyr absorbed in the rat intestinal membrane were successfully visualized. The proposed imaging method also provided useful information on intestinal peptide absorption; to some extent, Val-Tyr was rapidly hydrolyzed to Tyr by peptidases located at the intestinal microvillus during the absorption process. In conclusion, the strongly acidic additive, phytic acid, is beneficial for enhancing the visualization of small peptides using MALDI-IMS, owing to the suppression of ionization-interfering salts in the tissue.

  17. Turnaround time of positive blood cultures after the introduction of matrix-assisted laser desorption-ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Angeletti, Silvia; Dicuonzo, Giordano; D'Agostino, Alfio; Avola, Alessandra; Crea, Francesca; Palazzo, Carlo; Dedej, Etleva; De Florio, Lucia

    2015-07-01

    A comparative evaluation of the turnaround time (TAT) of positive blood culture before and after matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS) introduction in the laboratory routine was performed. A total of 643 positive blood cultures, of which 310 before and 333 after MALDI-TOF technique introduction, were collected. In the post MALDI-TOF period, blood culture median TAT decreased from 73.53 hours to 71.73 for Gram-positive, from 64.09 hours to 63.59 for Gram-negative and from 115.7 hours to 47.62 for anaerobes. MALDI-TOF significantly decreased the TAT of anaerobes, for which antimicrobial susceptibility test is not routinely performed. Furthermore, the major advantage of MALDI-TOF introduction was the decrease of the time for pathogen identification (TID) independently from the species with an improvement of 93% for Gram-positive, 86% for Gram-negative and 95% for anaerobes. In addition, high species-level identification rates and cost savings than conventional methods were achieved after MALDI-TOF introduction.

  18. Evaluation of a Semiquantitative Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method for Rapid Antimicrobial Susceptibility Testing of Positive Blood Cultures.

    Science.gov (United States)

    Jung, Jette S; Hamacher, Christina; Gross, Birgit; Sparbier, Katrin; Lange, Christoph; Kostrzewa, Markus; Schubert, Sören

    2016-11-01

    With the increasing prevalence of multidrug-resistant Gram-negative bacteria, rapid identification of the pathogen and its individual antibiotic resistance is crucial to ensure adequate antiinfective treatment at the earliest time point. Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for the identification of bacteria directly from the blood culture bottle has been widely established; however, there is still an urgent need for new methods that permit rapid resistance testing. Recently, a semiquantitative MALDI-TOF mass spectrometry-based method for the prediction of antibiotic resistance was described. We evaluated this method for detecting nonsusceptibility against two β-lactam and two non-β-lactam antibiotics. A collection of 30 spiked blood cultures was tested for nonsusceptibility against gentamicin and ciprofloxacin. Furthermore, 99 patient-derived blood cultures were tested for nonsusceptibility against cefotaxime, piperacillin-tazobactam, and ciprofloxacin in parallel with MALDI-TOF mass spectrometry identification from the blood culture fluid. The assay correctly classified all isolates tested for nonsusceptibility against gentamicin and cefotaxime. One misclassification for ciprofloxacin nonsusceptibility and five misclassifications for piperacillin-tazobactam nonsusceptibility occurred. Identification of the bacterium and prediction of nonsusceptibility was possible within approximately 4 h.

  19. Flexible Xxx–Asp/Asn and Gly–Xxx Residues of Equine Cytochrome c in Matrix-Assisted Laser Desorption/Ionization In-Source Decay Mass Spectrometry

    Science.gov (United States)

    Takayama, Mitsuo

    2012-01-01

    The backbone flexibility of a protein has been studied from the standpoint of the susceptibility of amino acid residues to in-source decay (ISD) in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Residues more susceptible to MALDI-ISD, namely Xxx–Asp/Asn and Gly–Xxx, were identified from the discontinuous intense peak of c′-ions originating from specific cleavage at N–Cα bonds of the backbone of equine cytochrome c. The identity of the residues susceptible to ISD was consistent with the known flexible backbone amides as estimated by hydrogen/deuterium exchange (HDX) experiments. The identity of these flexible amino acid residues (Asp, Asn, and Gly) is consistent with the fact that these residues are preferred in flexible secondary structure free from intramolecular hydrogen-bonded structures such as α-helix and β-sheet. The MALDI-ISD spectrum of equine cytochrome c gave not only intense N-terminal side c′-ions originating from N–Cα bond cleavage at Xxx–Asp/Asn and Gly–Xxx residues, but also C-terminal side complement z′-ions originating from the same cleavage sites. The present study implies that MALDI-ISD can give information about backbone flexibility of proteins, comparable with the protection factors estimated by HDX. PMID:24349908

  20. Discrimination of different species from the genus Drosophila by intact protein profiling using matrix-assisted laser desorption ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    Gröger-Arndt Helke

    2010-04-01

    Full Text Available Abstract Background The use of molecular biology-based methods for species identification and establishing phylogenetic relationships has supplanted traditional methods relying on morphological characteristics. While PCR-based methods are now the commonly accepted gold standards for these types of analysis, relatively high costs, time-consuming assay development or the need for a priori information about species-specific sequences constitute major limitations. In the present study, we explored the possibility to differentiate between 13 different species from the genus Drosophila via a molecular proteomic approach. Results After establishing a simple protein extraction procedure and performing matrix-assisted laser desorption/ionization (MALDI mass spectrometry (MS with intact proteins and peptides, we could show that most of the species investigated reproducibly yielded mass spectra that were adequate for species classification. Furthermore, a dendrogram generated by cluster analysis of total protein patterns agrees reasonably well with established phylogenetic relationships. Conclusion Considering the intra- and interspecies similarities and differences between spectra obtained for specimens of closely related Drosophila species, we estimate that species typing of insects and possibly other multicellular organisms by intact protein profiling (IPP can be established successfully for species that diverged from a common ancestor about 3 million years ago.

  1. Paraffin-wax-coated plates as matrix-assisted laser desorption/ionization sample support for high-throughput identification of proteins by peptide mass fingerprinting.

    Science.gov (United States)

    Tannu, Nilesh S; Wu, Jian; Rao, Vamshi K; Gadgil, Himanshu S; Pabst, Michael J; Gerling, Ivan C; Raghow, Rajendra

    2004-04-15

    We compared trysin-digested protein samples desalted by ZipTip(C18) reverse-phase microcolumns with on-plate washing of peptides deposited either on paraffin-coated plates (PCP), Teflon-based AnchorChip plates, or stainless steel plates, before analysis by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). Trypsinized bovine serum albumin and ovalbumin and 16 protein spots extracted from silver-stained two-dimensional gels of murine C(2)C(12) myoblasts or human leukocytes, prepared by the above two methods, were subjected to MALDI on PCP, AnchorChip plates, or uncoated stainless steel plates. Although most peptide mass peaks were identical regardless of the method of desalting and concentrating of protein samples, samples washed and concentrated by the PCP-based method had peptide peaks that were not seen in the samples prepared using the ZipTip(C18) columns. The mass spectra of peptides desalted and washed on uncoated stainless steel MALDI plates were consistently inferior due to loss of peptides. Some peptides of large molecular masses were apparently lost from samples desalted by ZipTip(C18) microcolumns, thus diminishing the quality of the fingerprint needed for protein identification. We demonstrate that the method of washing of protein samples on paraffin-coated plates provides an easy, reproducible, inexpensive, and high-throughput alternative to ZipTip(C18)-based purification of protein prior to MALDI-TOF-MS analysis.

  2. Detection of methicillin-resistant Staphylococcus aureus using phage amplification combined with matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Rees, Jon C; Barr, John R

    2017-02-01

    Antibiotic resistance continues to contribute significantly to morbidity and mortality across the world. Developing new tests for antibiotic-resistant bacteria is a core action to combat resistant infections. We describe a method that uses phage amplification detection (PAD) combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) to rapidly identify Staphylococcus aureus and determine phenotypic susceptibility to cefoxitin. Samples tested for S. aureus are incubated together with bacteriophage in the presence and absence of cefoxitin and subjected to rapid trypsin digestion followed by MALDI-MS analysis. Tryptic peptides derived from amplified phage proteins can be detected by MALDI-MS, as validated by time-of-flight (TOF)/TOF analysis of each peptide combined with database searching. Methicillin-resistant S. aureus show significant phage amplification in the presence of cefoxitin, while methicillin-sensitive S. aureus show no phage amplification relative to a no-antibiotic control. We also show that PAD methodology can be implemented on an FDA-approved commercial MALDI-MS bacterial identification system to identify S. aureus and determine antibiotic susceptibility. The novelty of this assay includes the use of phage-derived tryptic peptides as detected by MALDI-MS to monitor the results of PAD on an instrument common to many modern microbiology laboratories.

  3. Probing chain-end functionalization reactions in living anionic polymerization via matrix-assisted laser desorption ionization time-of-flight mass spectrometry

    Science.gov (United States)

    Arnould, Mark A.; Polce, Michael J.; Quirk, Roderic P.; Wesdemiotis, Chrys

    2004-11-01

    Matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) is applied to examine the products arising upon the preparation of chain-end functional polymers via living anionic polymerization techniques. Both post-polymerization functionalizations as well as the use of functionalized initiators are investigated. MALDI-TOF MS is shown to be a sensitive probe for the qualitative analysis of the major and minor oligomers from novel functionalization reactions whose mechanisms are not yet well established. The method is particularly valuable for the identification of the end groups of the minor, and often unexpected, distributions that may be undetectable by other analytical means. Complete characterization of all oligomers generated during functionalization reactions provides an essential tool to the synthetic chemist for understanding the corresponding mechanisms. This insight is necessary for selecting alternative routes or making modifications to the reaction conditions. It is demonstrated that MALDI-TOF MS can convey quantitative information about the yields of the chain-end groups introduced during functionalization. From the cases presented it is evident that post-polymerization reactions allow for better control of chain-end functionality and molecular weight than functionalization with the limited number of currently available protected functionalized initiators.

  4. Examination of the translocation of sulfonylurea herbicides in sunflower plants by matrix-assisted laser desorption/ionisation mass spectrometry imaging.

    Science.gov (United States)

    Anderson, David M G; Carolan, Vikki A; Crosland, Susan; Sharples, Kate R; Clench, Malcolm R

    2010-11-30

    Pesticides are widely used in agriculture to control weeds, pests and diseases. Successful control is dependent on the compound reaching the target site within the organism after spray or soil application. Conventional methods for determining uptake and movement of herbicides and pesticides include autoradiography, liquid scintillation and chromatographic techniques such as high-performance liquid chromatography (HPLC). Autoradiography using radiolabelled compounds provides the best indication of a compound's movement within the plant system. Autoradiography is an established technique but it relies on the synthesis of radiolabelled compounds. The distribution of four sulfonylurea herbicides in sunflower plants has been studied 24  h after foliar application. The use of matrix-assisted laser desorption/ionisation mass spectrometry imaging (MALDI-MSI) images of protonated molecules and fragment ions (resulting from fragmentation at the urea bond within the sulfonylurea herbicides) has provided evidence for translocation above and below the application point. The translocation of nicosulfuron and azoxystrobin within the same plant system has also been demonstrated following their application to the plant stem. This study provides evidence that MALDI-MSI has great potential as an analytical technique to detect and assess the foliar, root and stem uptake of agrochemicals, and to reveal their distribution through the plant once absorbed and translocated.

  5. Rapid Characterization of Microalgae and Microalgae Mixtures Using Matrix-Assisted Laser Desorption Ionization Time-Of-Flight Mass Spectrometry (MALDI-TOF MS)

    Science.gov (United States)

    Barbano, Duane; Diaz, Regina; Zhang, Lin; Sandrin, Todd; Gerken, Henri; Dempster, Thomas

    2015-01-01

    Current molecular methods to characterize microalgae are time-intensive and expensive. Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) may represent a rapid and economical alternative approach. The objectives of this study were to determine whether MALDI-TOF MS can be used to: 1) differentiate microalgae at the species and strain levels and 2) characterize simple microalgal mixtures. A common protein extraction sample preparation method was used to facilitate rapid mass spectrometry-based analysis of 31 microalgae. Each yielded spectra containing between 6 and 56 peaks in the m/z 2,000 to 20,000 range. The taxonomic resolution of this approach appeared higher than that of 18S rDNA sequence analysis. For example, two strains of Scenedesmus acutus differed only by two 18S rDNA nucleotides, but yielded distinct MALDI-TOF mass spectra. Mixtures of two and three microalgae yielded relatively complex spectra that contained peaks associated with members of each mixture. Interestingly, though, mixture-specific peaks were observed at m/z 11,048 and 11,230. Our results suggest that MALDI-TOF MS affords rapid characterization of individual microalgae and simple microalgal mixtures. PMID:26271045

  6. Identification of different respiratory viruses, after a cell culture step, by matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS)

    Science.gov (United States)

    Calderaro, Adriana; Arcangeletti, Maria Cristina; Rodighiero, Isabella; Buttrini, Mirko; Montecchini, Sara; Vasile Simone, Rosita; Medici, Maria Cristina; Chezzi, Carlo; De Conto, Flora

    2016-01-01

    In this study matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS), a reliable identification method for the diagnosis of bacterial and fungal infections, is presented as an innovative tool to investigate the protein profile of cell cultures infected by the most common viruses causing respiratory tract infections in humans. MALDI-TOF MS was applied to the identification of influenza A and B viruses, adenovirus C species, parainfluenza virus types 1, 2 and 3, respiratory syncytial virus, echovirus, cytomegalovirus and metapneumovirus. In this study MALDI-TOF MS was proposed as a model to be applied to the identification of cultivable respiratory viruses using cell culture as a viral proteins enrichment method to the proteome profiling of virus infected and uninfected cell cultures. The reference virus strains and 58 viruses identified from respiratory samples of subjects with respiratory diseases positive for one of the above mentioned viral agents by cell culture were used for the in vitro infection of suitable cell cultures. The isolated viral particles, concentrated by ultracentrifugation, were used for subsequent protein extraction and their spectra profiles were generated by MALDI-TOF MS analysis. The newly created library allowed us to discriminate between uninfected and respiratory virus infected cell cultures. PMID:27786297

  7. Comparing Laser Desorption Ionization and Atmospheric Pressure Photoionization Coupled to Fourier Transform Ion Cyclotron Resonance Mass Spectrometry To Characterize Shale Oils at the Molecular Level

    Science.gov (United States)

    Cho, Yunjo; Jin, Jang Mi; Witt, Matthias; Birdwell, Justin E.; Na, Jeong-Geol; Roh, Nam-Sun; Kim, Sunghwan

    2013-01-01

    Laser desorption ionization (LDI) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was used to analyze shale oils. Previous work showed that LDI is a sensitive ionization technique for assessing aromatic nitrogen compounds, and oils generated from Green River Formation oil shales are well-documented as being rich in nitrogen. The data presented here demonstrate that LDI is effective in ionizing high-double-bond-equivalent (DBE) compounds and, therefore, is a suitable method for characterizing compounds with condensed structures. Additionally, LDI generates radical cations and protonated ions concurrently, the distribution of which depends upon the molecular structures and elemental compositions, and the basicity of compounds is closely related to the generation of protonated ions. This study demonstrates that LDI FT-ICR MS is an effective ionization technique for use in the study of shale oils at the molecular level. To the best of our knowledge, this is the first time that LDI FT-ICR MS has been applied to shale oils.

  8. Proteomic profiling of hepatitis B virus-related hepatocellular carcinoma with magnetic bead-based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Taotao Liu; Ruyi Xue; Xiaowu Huang; Danying Zhang; Ling Dong; Hao Wu; Xizhong Shen

    2011-01-01

    Proteomic techniques are promising strategies in the surveillance of hepatocellular carcinoma (HCC). This study aimed to investigate the serum profiling with magnetic bead (MB) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) and to further identify the biomarkers for HCC. Serum samples from 80 chronic hepatitis B (CHB) patients, 94 HCC concomitant with HBV patients and 24 healthy subjects were examined by MALDI-TOF MS after peptide enrichment on MBs. Based on the genetic algorithm,diagnostic models for HCC were established between 30HCC patients and 24 healthy subjects/30 CHB patients.Validations were done with the remaining cases. Markers in the models were identified through liquid chromatography (LC)/MS-MS. The three groups were well separated from each other and two discrimination models were established for HCC. The overall recognition capability of these two models was 96.25% and 93.33%, respectively.Validations showed the misdiagnosis ratio for HCC was 1.6% and 23.4%, respectively. The identified biomarkers for HCC included prothrombin precursor (fragment),calcium-dependent secretion activator 1, Baculoviral inhibitor of apoptosis repeat-containing protein 6, etc.MB-based MALDI-TOF MS is applicable in identifying the serum biomarkers and can be used in the surveillance of HCC among HBV-infected patients.

  9. Application of Whole-Cell Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Identification and Clustering Analysis of Pantoea Species ▿ †

    Science.gov (United States)

    Rezzonico, Fabio; Vogel, Guido; Duffy, Brion; Tonolla, Mauro

    2010-01-01

    Pantoea agglomerans is an ecologically diverse taxon that includes commercially important plant-beneficial strains and opportunistic clinical isolates. Standard biochemical identification methods in diagnostic laboratories were repeatedly shown to run into false-positive identifications of P. agglomerans, a fact which is also reflected by the high number of 16S rRNA gene sequences in public databases that are incorrectly assigned to this species. More reliable methods for rapid identification are required to ascertain the prevalence of this species in clinical samples and to evaluate the biosafety of beneficial isolates. Whole-cell matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) methods and reference spectra (SuperSpectrum) were developed for accurate identification of P. agglomerans and related bacteria and used to detect differences in the protein profile within variants of the same strain, including a ribosomal point mutation conferring streptomycin resistance. MALDI-TOF MS-based clustering was shown to generally agree with classification based on gyrB sequencing, allowing rapid and reliable identification at the species level. PMID:20453125

  10. Rapid identification and typing of Yersinia pestis and other Yersinia species by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

    Science.gov (United States)

    Ayyadurai, Saravanan; Flaudrops, Christophe; Raoult, Didier; Drancourt, Michel

    2010-11-12

    Accurate identification is necessary to discriminate harmless environmental Yersinia species from the food-borne pathogens Yersinia enterocolitica and Yersinia pseudotuberculosis and from the group A bioterrorism plague agent Yersinia pestis. In order to circumvent the limitations of current phenotypic and PCR-based identification methods, we aimed to assess the usefulness of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) protein profiling for accurate and rapid identification of Yersinia species. As a first step, we built a database of 39 different Yersinia strains representing 12 different Yersinia species, including 13 Y. pestis isolates representative of the Antiqua, Medievalis and Orientalis biotypes. The organisms were deposited on the MALDI-TOF plate after appropriate ethanol-based inactivation, and a protein profile was obtained within 6 minutes for each of the Yersinia species. When compared with a 3,025-profile database, every Yersinia species yielded a unique protein profile and was unambiguously identified. In the second step of analysis, environmental and clinical isolates of Y. pestis (n = 2) and Y. enterocolitica (n = 11) were compared to the database and correctly identified. In particular, Y. pestis was unambiguously identified at the species level, and MALDI-TOF was able to successfully differentiate the three biotypes. These data indicate that MALDI-TOF can be used as a rapid and accurate first-line method for the identification of Yersinia isolates.

  11. Influence of secondary structure on in-source decay of protein in matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Takayama, Mitsuo; Osaka, Issey; Sakakura, Motoshi

    2012-01-01

    The susceptibility of the N-Cα bond of the peptide backbone to specific cleavage by in-source decay (ISD) in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) was studied from the standpoint of the secondary structure of three proteins. A naphthalene derivative, 5-amino-1-naphtol (5,1-ANL), was used as the matrix. The resulting c'-ions, which originate from the cleavage at N-Cα bonds in flexible secondary structures such as turn and bend, and are free from intra-molecular hydrogen-bonded α-helix structure, gave relatively intense peaks. Furthermore, ISD spectra of the proteins showed that the N-Cα bonds of specific amino acid residues, namely Gly-Xxx, Xxx-Asp, and Xxx-Asn, were more susceptible to MALDI-ISD than other amino acid residues. This is in agreement with the observation that Gly, Asp and Asn residues usually located in turns, rather than α-helix. The results obtained indicate that protein molecules embedded into the matrix crystal in the MALDI experiments maintain their secondary structures as determined by X-ray crystallography, and that MALDI-ISD has the capability for providing information concerning the secondary structure of protein.

  12. Discrimination of Bacillus anthracis Spores by Direct in-situ Analysis of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Youngsu; Lee, Jonghee; Kim, Seongsoo [Agency for Defense Development, Daejeon (Korea, Republic of)

    2013-09-15

    The rapid and accurate identification of biological agents is a critical step in the case of bio-terror and biological warfare attacks. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been widely used for the identification of microorganisms. In this study, we describe a method for the rapid and accurate discrimination of Bacillus anthracis spores using MALDI-TOF MS. Our direct in-situ analysis of MALDI-TOF MS does not involve subsequent high-resolution mass analyses and sample preparation steps. This method allowed the detection of species-specific biomarkers from each Bacillus spores. Especially, B. anthracis spores had specific biomarker peaks at 2503, 3089, 3376, 6684, 6698, 6753, and 6840 m/z. Cluster and PCA analyses of the mass spectra of Bacillus spores revealed distinctively separated clusters and within-groups similarity. Therefore, we believe that this method is effective in the real-time identification of biological warfare agents such as B. anthracis as well as other microorganisms in the field.

  13. Investigation of colloidal graphite as a matrix for matrix-assisted laser desorption/ionisation mass spectrometry of low molecular weight analytes.

    Science.gov (United States)

    Warren, Alexander D; Conway, Ulric; Arthur, Christopher J; Gates, Paul J

    2016-07-01

    The analysis of low molecular weight compounds by matrix-assisted laser desorption/ionisation mass spectrometry is problematic due to the interference and suppression of analyte ionisation by the matrices typically employed - which are themselves low molecular weight compounds. The application of colloidal graphite is demonstrated here as an easy to use matrix that can promote the ionisation of a wide range of analytes including low molecular weight organic compounds, complex natural products and inorganic complexes. Analyte ionisation with colloidal graphite is compared with traditional organic matrices along with various other sources of graphite (e.g. graphite rods and charcoal pencils). Factors such as ease of application, spectra reproducibility, spot longevity, spot-to-spot reproducibility and spot homogeneity (through single spot imaging) are explored. For some analytes, considerable matrix suppression effects are observed resulting in spectra completely devoid of matrix ions. We also report the observation of radical molecular ions [M(-●) ] in the negative ion mode, particularly with some aromatic analytes. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Differentiation of clinically relevant Mucorales Rhizopus microsporus and R. arrhizus by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Dolatabadi, Somayeh; Kolecka, Anna; Versteeg, Matthijs; de Hoog, Sybren G; Boekhout, Teun

    2015-07-01

    This study addresses the usefulness of matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) MS for reliable identification of the two most frequently occurring clinical species of Rhizopus, namely Rhizopus arrhizus with its two varieties, arrhizus and delemar, and Rhizopus microsporus. The test-set comprised 38 isolates of clinical and environmental origin previously identified by internal transcribed spacer (ITS) sequencing of rDNA. Multi-locus sequence data targeting three gene markers (ITS, ACT, TEF ) showed two monophylic clades for Rhizopus arrhizus and Rhizopus microsporus (bootstrap values of 99 %). Cluster analysis confirmed the presence of two distinct clades within Rhizopus arrhizus representing its varieties arrhizus and delemar. The MALDI Biotyper 3.0 Microflex LT platform (Bruker Daltonics) was used to confirm the distinction between Rhizopus arrhizus and Rhizopus microsporus and the presence of two varieties within the species Rhizopus arrhizus. An in-house database of 30 reference main spectra (MSPs) was initially tested for correctness using commercially available databases of Bruker Daltonics. By challenging the database with the same strains of which an in-house database was created, automatic identification runs confirmed that MALDI-TOF MS is able to recognize the strains at the variety level. Based on principal component analysis, two MSP dendrograms were created and showed concordance with the multi-locus tree; thus, MALDI-TOF MS is a useful tool for diagnostics of mucoralean species.

  15. Application of porous metal enrichment probe sampling to single cell analysis using matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS).

    Science.gov (United States)

    Fu, Qiang; Tang, Jun; Cui, Meng; Xing, Junpeng; Liu, Zhiqiang; Liu, Shuying

    2016-01-01

    There is an increasing need for analyzing metabolism in a single cell, which is important to understand the nature of cellular heterogeneity, disease, growth and specialization, etc. However, single cell analysis is often challenging for the traces of samples. In the present study, porous metal enrichment probe sampling combined with matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) has been applied for in situ analysis of live onion epidemic cell. Porous probe, treated by corroding copper wire with HCl, was directly inserted into a single cell to get cell solution. A self-made linear actuator was enough to control the penetration of probe into the target cell accurately. Then samples on the tip of probe were eluted and detected by a commercial MALDI-TOF-MS directly. The formation of porous microstructure on the probe surface increased the adsorptive capacity of cell solution. The sensitivity of porous probe sampling was 6 times higher than uncorroded probes generally. This method provides a sensitive and convenient way for the sampling and detection of single cell solution. Copyright © 2015 John Wiley & Sons, Ltd.

  16. A novel cluster of Mycobacterium abscessus complex revealed by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Suzuki, Hiromichi; Yoshida, Shiomi; Yoshida, Atsushi; Okuzumi, Katsuko; Fukusima, Atsuhito; Hishinuma, Akira

    2015-12-01

    Mycobacterium abscessus complex is a rapidly growing mycobacterium consisting of 3 subspecies, M. abscessus, Mycobacterium massiliense, and Mycobacterium bolletii. However, rapid and accurate species identification is difficult. We first evaluated a suitable protocol of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) for distinguishing these subspecies. Then, we studied spectral signals by MALDI-TOF MS in 59 M. abscessus, 42 M. massiliense, and 2 M. bolletii. Among several specific spectral signals, 4 signals clearly differentiate M. massiliense from the other 2 subspecies, M. abscessus and M. bolletii. Moreover, 6 of the 42 M. massiliense isolates showed a spectral pattern similar to M. abscessus. These isolates correspond to the distinctive class of M. massiliense (cluster D) which is closer to M. abscessus by the previous variable number tandem repeat analysis. These results indicate that MALDI-TOF MS is not only useful for the identification of 3 subspecies of M. abscessus complex but also capable of distinguishing clusters of M. massiliense.

  17. Enhanced reliability of avian influenza virus (AIV) and Newcastle disease virus (NDV) identification using matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS).

    Science.gov (United States)

    Jang, Ho Bin; Sung, Haan Woo; Nho, Seong Won; Park, Seong Bin; Cha, In Seok; Aoki, Takashi; Jung, Tae Sung

    2011-03-01

    In-solution enzymatic and nonenzymatic digestion methods have been successfully implemented in matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS)-based virus identification, extending to typing/subtyping of deadly influenza viruses. However, these methods are inefficient in obtaining more precise information on surface proteins of myxovirus particles, not only the hemagglutinin and neuraminidase of influenza virus but also the hemagglutinin-neuraminidase of Newcastle disease virus (NDV). Imbalances in viral protein composition cause ion suppression of tryptic fragments from low-abundant target proteins (surface proteins), adversely affecting reproducibility of mass spectra. Additionally, the coexistence of tryptic peptides from several proteins requires sophisticated statistical solutions for precise result interpretations. To circumvent these, we apply detergent-based (gel-free) partitioning of whole viruses into soluble surface proteins and insoluble virus materials, using differential centrifugation. MALDI-TOF or MALDI-TOF/TOF MS was applied to analyze tryptic peptides from separated viral proteins. In this study, we achieved type/subtype of avian influenza virus (AIV) within 5 h, based on 4 major proteins, by significantly reducing ion suppression and signal overlap from various protein sources. Hence, our approach can both yield dependable results and allow Web-based search engines to be directly employed, obviating the need for additional statistical strategy. Additionally, we demonstrate the utility of the method using NDV.

  18. Independent assessment of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) sample preparation quality: A novel statistical approach for quality scoring.

    Science.gov (United States)

    Kooijman, Pieter C; Kok, Sander J; Weusten, Jos J A M; Honing, Maarten

    2016-05-05

    Preparation of samples according to an optimized method is crucial for accurate determination of polymer sample characteristics by Matrix-Assisted Laser Desorption Ionization (MALDI) analysis. Sample preparation conditions such as matrix choice, cationization agent, deposition technique or even the deposition volume should be chosen to suit the sample of interest. Many sample preparation protocols have been developed and employed, yet finding the optimal sample preparation protocol remains a challenge. Because an objective comparison between the results of diverse protocols is not possible, "gut-feeling" or "good enough" is often decisive in the search for an optimum. This implies that sub-optimal protocols are used, leading to a loss of mass spectral information quality. To address this problem a novel analytical strategy based on MALDI imaging and statistical data processing was developed in which eight parameters were formulated to objectively quantify the quality of sample deposition and optimal MALDI matrix composition and finally sum up to an overall quality score of the sample deposition. These parameters can be established in a fully automated way using commercially available mass spectrometry imaging instruments without any hardware adjustments. With the newly developed analytical strategy the highest quality MALDI spots were selected, resulting in more reproducible and more valuable spectra for PEG in a variety of matrices. Moreover, our method enables an objective comparison of sample preparation protocols for any analyte and opens up new fields of investigation by presenting MALDI performance data in a clear and concise way.

  19. Detection of Staphylococcus aureus using 15N-labeled bacteriophage amplification coupled with matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry.

    Science.gov (United States)

    Pierce, Carrie L; Rees, Jon C; Fernández, Facundo M; Barr, John R

    2011-03-15

    A novel approach to rapid bacterial detection using an isotopically labeled (15)N bacteriophage and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) is introduced. Current phage amplification detection (PAD) via mass spectrometric analysis is limited because host bacteria must be inoculated with low phage titers in such a way that initial infecting phage concentrations must be below the detection limit of the instrument, thus lengthening incubation times. Additionally, PAD techniques cannot distinguish inoculate input phage from output phage which can increase the possibility of false positive results. Here, we report a rapid and accurate PAD approach for identification of Staphylococcus aureus via detection of bacteriophage capsid proteins. This approach uses both a wild-type (14)N and a (15)N-isotopically labeled S. aureus-specific bacteriophage. High (15)N phage titers, above our instrument's detection limits, were used to inoculate S. aureus. MALDI-TOF MS detection of the (14)N progeny capsid proteins in the phage-amplified culture indicated the presence of the host bacteria. Successful phage amplification was observed after 90 min of incubation. The amplification was observed by both MALDI-TOF MS analysis and by standard plaque assay measurements. This method overcomes current limitations by improving analysis times while increasing selectivity when compared to previously reported PAD methodologies.

  20. Study of a complex environmental mixture by electrospray ionization and laser desorption ionization high resolution mass spectrometry: the cigarette smoke aerosol

    Directory of Open Access Journals (Sweden)

    Vincent Carré

    2015-06-01

    Full Text Available Aerosols from the mainstream cigarette smoke have been analyzed by electrospray ionization (ESI coupled to Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS. Measurements have been conducted in positive ion mode. The chemical composition of cigarette smoke aerosol is significant because it gives insights of one complex indoor environmental mixture. Almost 1300 chemical compositions relative to nitrogen species were successfully determined through the accurate mass measurement and the good ion production of the used technique. The most abundant class of compounds corresponds to N2 one (hydrocarbons with two nitrogen atoms. For other classes, the van Krevelen diagrams ensured to define that other nitrogen and oxygen-nitrogen compounds adopted similar behavior in terms of unsaturation and alkylation range. The detailed composition of cigarette smoke aerosol provided a typical chemical fingerprint from the biomass pyrolysis with tobacco-specific compounds. We examined also the contribution of laser desorption ionization (LDI technique coupled to FTICRMS for the acute analysis of cigarette smoke aerosol. While a part of the chemical composition were found similar to ESI results, LDI achieved a broader range of poly-aromatic compounds and highlight new class compounds as pure hydrocarbon and oxygen-containing species. The combination of ESI and LDI with high resolution mass spectrometry clearly increased significantly the coverage of the “whole composition” of environmental aerosols such as cigarette smoke aerosol.

  1. BioAerosol Mass Spectrometry: Reagentless Detection of Individual Airborne Spores and Other Bioagent Particles Based on Laser Desorption/Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Steele, Paul Thomas [Univ. of California, Davis, CA (United States)

    2004-09-01

    Better devices are needed for the detection of aerosolized biological warfare agents. Advances in the ongoing development of one such device, the BioAerosol Mass Spectrometry (BAMS) system, are described here in detail. The system samples individual, micrometer-sized particles directly from the air and analyzes them in real-time without sample preparation or use of reagents. At the core of the BAMS system is a dual-polarity, single-particle mass spectrometer with a laser based desorption and ionization (DI) system. The mass spectra produced by early proof-of-concept instruments were highly variable and contained limited information to differentiate certain types of similar biological particles. The investigation of this variability and subsequent changes to the DI laser system are described. The modifications have reduced the observed variability and thereby increased the usable information content in the spectra. These improvements would have little value without software to analyze and identify the mass spectra. Important improvements have been made to the algorithms that initially processed and analyzed the data. Single particles can be identified with an impressive level of accuracy, but to obtain significant reductions in the overall false alarm rate of the BAMS instrument, alarm decisions must be made dynamically on the basis of multiple analyzed particles. A statistical model has been developed to make these decisions and the resulting performance of a hypothetical BAMS system is quantitatively predicted. The predictions indicate that a BAMS system, with reasonably attainable characteristics, can operate with a very low false alarm rate (orders of magnitude lower than some currently fielded biodetectors) while still being sensitive to small concentrations of biological particles in a large range of environments. Proof-of-concept instruments, incorporating some of the modifications described here, have already performed well in independent testing.

  2. Analysis of trimethoprim, lincomycin, sulfadoxin and tylosin in swine manure using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Solliec, Morgan; Massé, Daniel; Sauvé, Sébastien

    2014-10-01

    A new extraction method coupled to a high throughput sample analysis technique was developed for the determination of four veterinary antibiotics. The analytes belong to different groups of antibiotics such as chemotherapeutics, sulfonamides, lincosamides and macrolides. Trimethoprim (TMP), sulfadoxin (SFX), lincomycin (LCM) and tylosin (TYL) were extracted from lyophilized manure using a sonication extraction. McIlvaine buffer and methanol (MeOH) were used as extraction buffers, followed by cation-exchange solid phase extraction (SPE) for clean-up. Analysis was performed by laser diode thermal desorption-atmospheric pressure chemical-ionization (LDTD-APCI) tandem mass spectrometry (MS/MS) with selected reaction monitoring (SRM) detection. The LDTD is a high throughput sample introduction method that reduces total analysis time to less than 15s per sample, compared to minutes when using traditional liquid chromatography (LC). Various SPE parameters were optimized after sample extraction: the stationary phase, the extraction solvent composition, the quantity of sample extracted and sample pH. LDTD parameters were also optimized: solvent deposition, carrier gas, laser power and corona discharge. The method limit of detection (MLD) ranged from 2.5 to 8.3 µg kg(-1) while the method limit of quantification (MLQ) ranged from 8.3 to 28µgkg(-1). Calibration curves in the manure matrix showed good linearity (R(2)≥ 0.996) for all analytes and the interday and intraday coefficients of variation were below 14%. Recoveries of analytes from manure ranged from 53% to 69%. The method was successfully applied to real manure samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. BioAerosol Mass Spectrometry: Reagentless Detection of Individual Airborne Spores and Other Bioagent Particles Based on Laser Desorption/Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Steele, P T

    2004-07-20

    Better devices are needed for the detection of aerosolized biological warfare agents. Advances in the ongoing development of one such device, the BioAerosol Mass Spectrometry (BAMS) system, are described here in detail. The system samples individual, micrometer-sized particles directly from the air and analyzes them in real-time without sample preparation or use of reagents. At the core of the BAMS system is a dual-polarity, single-particle mass spectrometer with a laser based desorption and ionization (DI) system. The mass spectra produced by early proof-of-concept instruments were highly variable and contained limited information to differentiate certain types of similar biological particles. The investigation of this variability and subsequent changes to the DI laser system are described. The modifications have reduced the observed variability and thereby increased the usable information content in the spectra. These improvements would have little value without software to analyze and identify the mass spectra. Important improvements have been made to the algorithms that initially processed and analyzed the data. Single particles can be identified with an impressive level of accuracy, but to obtain significant reductions in the overall false alarm rate of the BAMS instrument, alarm decisions must be made dynamically on the basis of multiple analyzed particles. A statistical model has been developed to make these decisions and the resulting performance of a hypothetical BAMS system is quantitatively predicted. The predictions indicate that a BAMS system, with reasonably attainable characteristics, can operate with a very low false alarm rate (orders of magnitude lower than some currently fielded biodetectors) while still being sensitive to small concentrations of biological particles in a large range of environments. Proof-of-concept instruments, incorporating some of the modifications described here, have already performed well in independent testing.

  4. 1,8-Bis(dimethylamino)naphthalene/9-aminoacridine: A new binary matrix for lipid fingerprinting of intact bacteria by matrix assisted laser desorption ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Calvano, C.D., E-mail: cosimadamiana.calvano@uniba.it [Dipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via Orabona, 4, 70126 Bari (Italy); Monopoli, A.; Ditaranto, N. [Dipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via Orabona, 4, 70126 Bari (Italy); Palmisano, F. [Dipartimento di Chimica, Università degli Studi di Bari Aldo Moro, Via Orabona, 4, 70126 Bari (Italy); Centro Interdipartimentale di Ricerca S.M.A.R.T., Università degli Studi di Bari Aldo Moro, Via Orabona, 4, 70126 Bari (Italy)

    2013-10-10

    Graphical abstract: -- Highlights: •New binary matrix for less ionizable lipid analysis with no interfering peaks. •Combined MALDI and X-ray photoelectron spectroscopy (XPS) analyses. •Fast lipid fingerprint on Gram positive and Gram negative bacteria by MALDI MS. •Mapping of phospholipids by XPS imaging. •Very fast membrane lipid extraction procedure. -- Abstract: The effectiveness of a novel binary matrix composed of 1,8-bis(dimethylamino)naphthalene (DMAN; proton sponge) and 9-aminoacridine (9AA) for the direct lipid analysis of whole bacterial cells by matrix assisted laser desorption ionization mass spectrometry (MALDI MS) is demonstrated. Deprotonated analyte signals nearly free of matrix-related ions were observed in negative ion mode. The effect of the most important factors (laser energy, pulse voltage, DMAN/9AA ratio, analyte/matrix ratio) was investigated using a Box–Behnken response surface design followed by multi-response optimization in order to simultaneously maximize signal-to-noise (S/N) ratio and resolution. The chemical surface composition of single or mixed matrices was explored by X-ray photoelectron spectroscopy (XPS). Moreover, XPS imaging was used to map the spatial distribution of a model phospholipid in single or binary matrices. The DMAN/9AA binary matrix was then successfully applied to the analysis of intact Gram positive (Lactobacillus sanfranciscensis) or Gram negative (Escherichia coli) microorganisms. About fifty major membrane components (free fatty acids, mono-, di- and tri-glycerides, phospholipids, glycolipids and cardiolipins) were quickly and easily detected over a mass range spanning from ca. 200 to ca. 1600 m/z. Moreover, mass spectra with improved S/N ratio (compared to single matrices), reduced chemical noise and no formation of matrix-clusters were invariably obtained demonstrating the potential of this binary matrix to improve sensitivity.

  5. Laser-induced oxidation of cholesterol observed during MALDI-TOF mass spectrometry

    Science.gov (United States)

    Conditions for the detection of three odd-electron cholesterol oxidation peaks were determined and these peaks were shown to be artifacts of the matrix-assisted laser desorption time of flight (MALDI-TOF) process. Matrix choice, solvent, laser intensity and cholesterol concentration were systematica...

  6. Laser-induced damage of 1064-nm narrow-band interference filters under different laser modes

    Institute of Scientific and Technical Information of China (English)

    Weidong Gao(高卫东); Hongbo He(贺洪波); Jianda Shao(邵建达); Zhengxiu Fan(范正修)

    2004-01-01

    The laser-induced damage behavior of narrow-band interference filters was investigated with a Nd:YAG laser at 1064 nm under single-pulse mode and free-running laser mode.The absorption measurement of such coatings has been performed by surface thermal lensing(STL)technique.The relationship between damage morphology and absorption under the two different laser modes was studied in detail.The explanation was given by the standing-wave distribution theory.

  7. Laser filament-induced aerosol formation

    Directory of Open Access Journals (Sweden)

    H. Saathoff

    2013-05-01

    Full Text Available Using the aerosol and cloud simulation chamber AIDA, we investigated the laser filament induced particle formation in ambient air, humid synthetic air, humid nitrogen, argon–oxygen mixture, and pure argon in order to simulate the particle formation under realistic atmospheric conditions as well as to investigate the influence of typical gas-phase atmospheric constituents on the particle formation. Terawatt laser plasma filaments generated new particles in the size range 3 to 130 nm with particle production rates ranging from 1 × 107 to 5 × 109 cm−3 plasma s−1 for the given experimental conditions. In all cases the particle formation rates increased exponentially with the water content of the gas mixture. Furthermore, the presence of a few ppb of trace gases like SO2 and α-pinene clearly enhanced the particle yield by number, the latter also by mass. Our findings suggest that new particle formation is efficiently supported by oxidized species like acids generated by the photoionization of both major and minor components of the air, including N2, NH3, SO2 and organics.

  8. Laser filament-induced aerosol formation

    Directory of Open Access Journals (Sweden)

    H. Saathoff

    2012-11-01

    Full Text Available Using the aerosol and cloud simulation chamber AIDA we investigated the laser filament induced particle formation in ambient air, humid synthetic air, humid nitrogen, argon-oxygen mixture, and pure argon in order to simulate the particle formation under realistic atmospheric conditions as well as to investigate the influence of typical gas-phase atmospheric constituents on the particle formation. Terawatt laser plasma filaments generated new particles in the size range 3 to 130 nm with particle production rates ranging from 1 × 107 to 5 × 109 cm−3 plasma s−1. In all cases the particle formation rates increased exponentially with the water content of the gas mixture. Furthermore, the presence of a few ppb of trace gases like SO2 and α-pinene clearly enhanced the particle yield by number, the latter also by mass. Our findings suggest that new particle formation is efficiently supported by acids generated by the photo-ionization of both major and minor components of the air, including N2, NH3, SO2 and organics.

  9. Effect of native defects and laser-induced defects on multi-shot laser-induced damage in multilayer mirrors

    Institute of Scientific and Technical Information of China (English)

    Ying Wang; Yuanan Zhao; Tanda Shao; Zhengxiu Fan

    2011-01-01

    The roles of laser-induced defects and native defects in multilayer mirrors under multi-shot irradiation condition are investigated. The HfO2/SiO2 dielectric mirrors are deposited by electron beam evaporation (EBE). Laser damage testing is carried out on both the 1-on-l and S-on-1 regimes using 355-nm pulsed laser at a duration of 8 ns. It is found that the single-shot laser-induced damage threshold (LIDT) is much higher than the multi-shot LIDT. In the multi-shot mode, the main factor influencing LIDT is the accumulation of irreversible laser-induced defects and native defects. The surface morphologies of the samples are observed by optical microscopy. Moreover, the number of laser-induced defects affects the damage probability of the samples. A correlative model based on critical conduction band (CB) electron density (ED) is presented to simulate the multi-shot damage behavior.%@@ The roles of laser-induced defects and native defects in multilayer mirrors under multi-shot irradiation condition are investigated.The Hf02/SiO2 dielectric mirrors are deposited by electron beam evaporation (EBE).Laser damage testing is carried out on both the 1-on-1 and S-on-1 regimes using 355-nn pulsed laser at a duration of 8 us.It is found that the single-shot laser-induced damage threshold(LIDT)is much higher than the multi-shot LIDT.In the multi-shot mode,the main factor influencing LIDT is the accumulation of irreversible laser-induced defects and native defects.The surface morphologies of the samples are observed by optical microscopy.Moreover,the number of laser-induced defects affects the damage probability of the samples.A correlative model based on critical conduction band(CB)electron density(ED)is presented to simulate the multi-shot damage behavior.

  10. Laser-induced periodic surface structuring of biopolymers

    Science.gov (United States)

    Pérez, Susana; Rebollar, Esther; Oujja, Mohamed; Martín, Margarita; Castillejo, Marta

    2013-03-01

    We report here on a systematic study about the formation of laser-induced periodic surface structures (LIPSS) on biopolymers. Self-standing films of the biopolymers chitosan, starch and the blend of chitosan with the synthetic polymer poly (vinyl pyrrolidone), PVP, were irradiated in air with linearly polarized laser beams at 193, 213 and 266 nm, with pulse durations in the range of 6-17 ns. The laser-induced periodic surface structures were topographically characterized by atomic force microscopy and the chemical modifications induced by laser irradiation were inspected via Raman spectroscopy. Formation of LIPSS parallel to the laser polarization direction, with periods similar to the laser wavelength, was observed at efficiently absorbed wavelengths in the case of the amorphous biopolymer chitosan and its blend with PVP, while formation of LIPSS is prevented in the crystalline starch biopolymer.

  11. Ceria nanocubic-ultrasonication assisted dispersive liquid-liquid microextraction coupled with matrix assisted laser desorption/ionization mass spectrometry for pathogenic bacteria analysis.

    Science.gov (United States)

    Abdelhamid, Hani Nasser; Bhaisare, Mukesh L; Wu, Hui-Fen

    2014-03-01

    A new ceria (CeO2) nanocubic modified surfactant is used as the basis of a novel nano-based microextraction technique for highly sensitive detection of pathogenic bacteria (Pseudomonas aeruginosa and Staphylococcus aureus). The technique uses ultrasound enhanced surfactant-assisted dispersive liquid-liquid microextraction (UESA-DLLME) with and without ceria (CeO2) followed by matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS). In order to achieve high separation efficiency, we investigated the influential parameters, including extraction time of ultrasonication, type and volume of the extraction solvent and surfactant. Among various surfactants, the cationic surfactants can selectively offer better extraction efficiency on bacteria analysis than that of the anionic surfactants due to the negative charges of bacteria cell membranes. Extractions of the bacteria lysate from aqueous samples via UESA-DLLME-MALDI-MS were successfully achieved by using cetyltrimethyl ammonium bromide (CTAB, 10.0 µL, 1.0×10(-3) M) as surfactants in chlorobenzene (10.0 µL) and chloroform (10.0 µL) as the optimal extracting solvent for P. aeruginosa and S. aureus, respectively. Ceria nanocubic was synthesized, and functionalized with CTAB (CeO2@CTAB) and then characterized using transmission electron microscopy (TEM) and optical spectroscopy (UV and FTIR). CeO2@CTAB demonstrates high extraction efficiency, improve peaks ionization, and enhance resolution. The prime reasons for these improvements are due to the large surface area of nanoparticles, and its absorption that coincides with the wavelength of MALDI laser (337 nm, N2 laser). CeO2@CTAB-based microextraction offers lowest detectable concentrations tenfold lower than that of without nanoceria. The present approach has been successfully applied to detect pathogenic bacteria at low concentrations of 10(4)-10(5) cfu/mL (without ceria) and at 10(3)-10(4) cfu/mL (with ceria) from bacteria suspensions. Finally, the

  12. Analysis of Single Nucleotide Polymorphism in Human Paraoxonase 1 Gene(Q192R) with Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500-1000 nucleotides[1]. A variety of methods have been used for the analysis of single nucleotide polymorphisms, including restriction fragment length polymorphism (RFLP) [2], direct sequencing by using laser-induced fluorescence detection[3], fluorescence energy transfer[4], MALDI-TOF MS combined with primer extension or invasive cleavage[5,6] , and fluorescence polarization[7].

  13. Laser induced periodic surface structure formation in germanium above laser damage fluence by mid IR femtosecond laser irradiation

    Science.gov (United States)

    Kafka, Kyle; Austin, Drake; Cheng, Jian; Trendafilov, Simeon; Shvets, Gennady; Li, Hui; Yi, Allen; Blaga, Cosmin I.; DiMauro, L. F.; Chowdhury, Enam

    2014-11-01

    Laser induced periodic surface structures (LIPSS) were generated via interaction of multiple 90 femtosecond 1900 - 3600 nm mid IR laser pulses (3 -10,000) on single crystal Ge targets. For specific laser parameters, both low and high frequency LIPSS are found together, which are oriented perpendicular to each other. Study of polarization dependence of LIPSS revealed that orientation and symmetry of interaction could be controlled by rotating polarization of laser pulses. Low frequency LIPSS formation was consistent with surface plasmon coupling of laser pulses with excited Ge.

  14. MoS2/Ag nanohybrid: A novel matrix with synergistic effect for small molecule drugs analysis by negative-ion matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Zhao, Yaju; Deng, Guoqing; Liu, Xiaohui; Sun, Liang; Li, Hui; Cheng, Quan; Xi, Kai; Xu, Danke

    2016-09-21

    This paper reports a facile synthesis of molybdenum disulfide nanosheets/silver nanoparticles (MoS2/Ag) hybrid and its use as an effective matrix in negative ion matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The nanohybrid exerts a strong synergistic effect, leading to high performance detection of small molecule analytes including amino acids, peptides, fatty acids and drugs. The enhancement of laser desorption/ionization (LDI) efficiency is largely attributed to the high surface roughness and large surface area for analyte adsorption, better dispersibility, increased thermal conductivity and enhanced UV energy absorption as compared to pure MoS2. Moreover, both Ag nanoparticles and the edge of the MoS2 layers function as deprotonation sites for proton capture, facilitating the charging process in negative ion mode and promoting formation of negative ions. As a result, the MoS2/Ag nanohybrid proves to be a highly attractive matrix in MALDI-TOF MS, with desired features such as high desorption/ionization efficiency, low fragmentation interference, high salt tolerance, and no sweet-spots for mass signal. These characteristic properties allowed for simultaneous analysis of eight different drugs and quantification of acetylsalicylic acid in the spiked human serum. This work demonstrates for the first time the fabrication and application of a novel MoS2/Ag hybrid, and provides a new platform for use in the rapid and high throughput analysis of small molecules by mass spectrometry.

  15. Tissue tearing caused by pulsed laser-induced ablation pressure.

    Science.gov (United States)

    Cummings, J P; Walsh, J T

    1993-02-01

    Pressure induced by ablative pulses of laser radiation is shown to correlate with the mechanical disruption of tissue. The ablation pressure induced during Er:YSGG laser irradiation of skin, liver, and aorta was calculated from a ballistic pendulum-based measurement of recoil momentum. The ejected material and ablation crater were examined grossly and microscopically after ablation. A gas-dynamic model of laser-induced vaporization was used to understand the measured pressures. The results show that mechanical disruption of tissue occurs when the ablation pressure exceeds the strength of the irradiated tissue at sites of intrinsic weakness.

  16. Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Combined Species Identification and Drug Sensitivity Testing in Mycobacteria.

    Science.gov (United States)

    Ceyssens, Pieter-Jan; Soetaert, Karine; Timke, Markus; Van den Bossche, An; Sparbier, Katrin; De Cremer, Koen; Kostrzewa, Markus; Hendrickx, Marijke; Mathys, Vanessa

    2017-02-01

    Species identification and drug susceptibility testing (DST) of mycobacteria are important yet complex processes traditionally reserved for reference laboratories. Recent technical improvements in matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has started to facilitate routine mycobacterial identifications in clinical laboratories. In this paper, we investigate the possibility of performing phenotypic MALDI-based DST in mycobacteriology using the recently described MALDI Biotyper antibiotic susceptibility test rapid assay (MBT-ASTRA). We randomly selected 72 clinical Mycobacterium tuberculosis and nontuberculous mycobacterial (NTM) strains, subjected them to MBT-ASTRA methodology, and compared its results to current gold-standard methods. Drug susceptibility was tested for rifampin, isoniazid, linezolid, and ethambutol (M. tuberculosis, n = 39), and clarithromycin and rifabutin (NTM, n = 33). Combined species identification was performed using the Biotyper Mycobacteria Library 4.0. Mycobacterium-specific MBT-ASTRA parameters were derived (calculation window, m/z 5,000 to 13,000, area under the curve [AUC] of >0.015, relative growth [RG] of drug resistance profiles which corresponded to standard testing results. Turnaround times were not significantly different in M. tuberculosis testing, but the MBT-ASTRA method delivered on average a week faster than routine DST in NTM. Databases searches returned 90.4% correct species-level identifications, which increased to 98.6% when score thresholds were lowered to 1.65. In conclusion, the MBT-ASTRA technology holds promise to facilitate and fasten mycobacterial DST and to combine it directly with high-confidence species-level identifications. Given the ease of interpretation, its application in NTM typing might be the first in finding its way to current diagnostic workflows. However, further validations and automation are required before routine implementation can be envisioned

  17. Natural products in Glycyrrhiza glabra (licorice) rhizome imaged at the cellular level by atmospheric pressure matrix-assisted laser desorption/ionization tandem mass spectrometry imaging.

    Science.gov (United States)

    Li, Bin; Bhandari, Dhaka Ram; Janfelt, Christian; Römpp, Andreas; Spengler, Bernhard

    2014-10-01

    The rhizome of Glycyrrhiza glabra (licorice) was analyzed by high-resolution mass spectrometry imaging and tandem mass spectrometry imaging. An atmospheric pressure matrix-assisted laser desorption/ionization imaging ion source was combined with an orbital trapping mass spectrometer in order to obtain high-resolution imaging in mass and space. Sections of the rhizome were imaged with a spatial resolution of 10 μm in the positive ion mode, and a large number of secondary metabolites were localized and identified based on their accurate mass and MS/MS fragmentation patterns. Major tissue-specific metabolites, including free flavonoids, flavonoid glycosides and saponins, were successfully detected and visualized in images, showing their distributions at the cellular level. The analytical power of the technique was tested in the imaging of two isobaric licorice saponins with a mass difference of only 0.02 Da. With a mass resolving power of 140 000 and a bin width of 5 ppm in the image processing, the two compounds were well resolved in full-scan mode, and appeared with different distributions in the tissue sections. The identities of the compounds and their distributions were validated in a subsequent MS/MS imaging experiment, thereby confirming their identities and excluding possible analyte interference. The use of high spatial resolution, high mass resolution and tandem mass spectrometry in imaging experiments provides significant information about the biosynthetic pathway of flavonoids and saponins in legume species, combing the spatially resolved chemical information with morphological details at the microscopic level. Furthermore, the technique offers a scheme capable of high-throughput profiling of metabolites in plant tissues.

  18. Automated coupling of capillary-HPLC to matrix-assisted laser desorption/ionization mass spectrometry for the analysis of small molecules utilizing a reactive matrix.

    Science.gov (United States)

    Brombacher, Stephan; Owen, Stacey J; Volmer, Dietrich A

    2003-07-01

    This study describes the application of a novel, reactive matrix for the mass spectral analysis of steroids by capillary-high performance liquid chromatography (capillary-HPLC) coupled to matrix-assisted laser desorption/ionization (MALDI). The mass spectral analysis of steroids was accomplished after fully automated peak deposition of chromatographic peaks onto MALDI targets. The seven corticosteroids used as test compounds were: triamcinolone, prednisone, cortisone, fludrocortisone, dexamethasone, deoxycorticosterone, and budesonide. They were separated using a PepMap C(18) (3 microm particle size, 100 A pore width) column at five different concentration levels of 25, 15, 7.5, 2.5 and 1 ng/microL, and the peaks were detected at a wavelength of 237 nm. The column effluent was mixed with 2,4-dinitrophenylhydrazine (DNPH) directly following the UV detector. The chromatographic peaks were then deposited onto the MALDI target with a robotic micro-fraction collector triggered by the UV detector signals. A special hydrophobic surface coating allowed the deposition of up to 4 microL (up to 90 % of the chromatographic peak volume) onto one sample spot. The compounds were then identified by MALDI mass spectrometry. Depending on the nature of the analyte, radical cations ([M](+.)) and sodium adduct ions ([M+Na](+)) of the steroids as well as protonated steroid-dinitrophenylhydrazone derivatives ([M(D)+H](+)) were detected in positive ion mode. The detection limits were between 0.5 and 15 ng injected with capillary-HPLC-MALDI-TOF-MS and between 0.3 and 3 ng on target with MALDI-TOF when deposited manually.

  19. Liquid chromatography electrospray ionization and matrix-assisted laser desorption ionization tandem mass spectrometry for the analysis of lipid raft proteome of monocytes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Nan [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Shaw, Andrew R.E. [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)], E-mail: andrewsh@cancerboard.ab.ca; Li Nan; Chen Rui [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Mak, Allan; Hu Xiuying [Department of Oncology, University of Alberta, Edmonton, Alberta (Canada); Young, Nelson; Wishart, David [Department of Computing Science, University of Alberta, Edmonton, Alberta (Canada); Li Liang, E-mail: Liang.Li@ualberta.ca

    2008-10-03

    Lipid rafts are dynamic assemblies of cholesterol and glycolipid that form detergent-insoluble microdomains within membrane lipid bilayers. Because rafts can be separated by flotation on sucrose gradients, interrogation by mass spectrometry (MS) provides a valuable new insight into lipid raft function. Here we combine liquid chromatography (LC) electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) MS/MS to corroborate and extend our previous description of lipid raft proteomes derived from the monocytic cell line THP-1. Interestingly, LC-ESI and MALDI MS/MS identify largely non-overlapping, and therefore, potentially complementary protein populations. Using the combined approach, we detected 277 proteins compared to 52 proteins obtained with the original gel-based MALDI MS. We confirmed the presence of 47 of the original 52 proteins demonstrating the consistency of the lipid raft preparations. We demonstrated by immunoblotting that Rac 1 and Rac 2, two of the 52 proteins we failed to confirm, were indeed absent from the lipid raft fractions. The majority of new proteins were cytoskeletal proteins and their regulators, proteins implicated in membrane fusion and vesicular trafficking or signaling molecules. Our results therefore, confirm and extend previous evidence indicating lipid rafts of monocytic cells are specialized for cytoskeletal assembly and vesicle trafficking. Of particular interest, we detected SNAP-23, basigin, Glut-4 and pantophysin in lipid rafts. Since these proteins are implicated in both vesicular trafficking and gamete fusion, lipid rafts may play a common role in these processes. It is evident that the combination of LC-ESI and LC-MALDI MS/MS increases the proteome coverage which allows better understanding of the lipid raft function.

  20. Optimizing identification of clinically relevant Gram-positive organisms by use of the Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry system.

    Science.gov (United States)

    McElvania Tekippe, Erin; Shuey, Sunni; Winkler, David W; Butler, Meghan A; Burnham, Carey-Ann D

    2013-05-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) can be used as a method for the rapid identification of microorganisms. This study evaluated the Bruker Biotyper (MALDI-TOF MS) system for the identification of clinically relevant Gram-positive organisms. We tested 239 aerobic Gram-positive organisms isolated from clinical specimens. We evaluated 4 direct-smear methods, including "heavy" (H) and "light" (L) smears, with and without a 1-μl direct formic acid (FA) overlay. The quality measure assigned to a MALDI-TOF MS identification is a numerical value or "score." We found that a heavy smear with a formic acid overlay (H+FA) produced optimal MALDI-TOF MS identification scores and the highest percentage of correctly identified organisms. Using a score of ≥2.0, we identified 183 of the 239 isolates (76.6%) to the genus level, and of the 181 isolates resolved to the species level, 141 isolates (77.9%) were correctly identified. To maximize the number of correct identifications while minimizing misidentifications, the data were analyzed using a score of ≥1.7 for genus- and species-level identification. Using this score, 220 of the 239 isolates (92.1%) were identified to the genus level, and of the 181 isolates resolved to the species level, 167 isolates (92.2%) could be assigned an accurate species identification. We also evaluated a subset of isolates for preanalytic factors that might influence MALDI-TOF MS identification. Frequent subcultures increased the number of unidentified isolates. Incubation temperatures and subcultures of the media did not alter the rate of identification. These data define the ideal bacterial preparation, identification score, and medium conditions for optimal identification of Gram-positive bacteria by use of MALDI-TOF MS.

  1. Validation of a New Web Application for Identification of Fungi by Use of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Normand, A C; Becker, P; Gabriel, F; Cassagne, C; Accoceberry, I; Gari-Toussaint, M; Hasseine, L; De Geyter, D; Pierard, D; Surmont, I; Djenad, F; Donnadieu, J L; Piarroux, M; Ranque, S; Hendrickx, M; Piarroux, R

    2017-09-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry has emerged as a reliable technique to identify molds involved in human diseases, including dermatophytes, provided that exhaustive reference databases are available. This study assessed an online identification application based on original algorithms and an extensive in-house reference database comprising 11,851 spectra (938 fungal species and 246 fungal genera). Validation criteria were established using an initial panel of 422 molds, including dermatophytes, previously identified via DNA sequencing (126 species). The application was further assessed using a separate panel of 501 cultured clinical isolates (88 mold taxa including dermatophytes) derived from five hospital laboratories. A total of 438 (87.35%) isolates were correctly identified at the species level, while 26 (5.22%) were assigned to the correct genus but the wrong species and 37 (7.43%) were not identified, since the defined threshold of 20 was not reached. The use of the Bruker Daltonics database included in the MALDI Biotyper software resulted in a much higher rate of unidentified isolates (39.76 and 74.30% using the score thresholds 1.7 and 2.0, respectively). Moreover, the identification delay of the online application remained compatible with real-time online queries (0.15 s per spectrum), and the application was faster than identifications using the MALDI Biotyper software. This is the first study to assess an online identification system based on MALDI-TOF spectrum analysis. We have successfully applied this approach to identify molds, including dermatophytes, for which diversity is insufficiently represented in commercial databases. This free-access application is available to medical mycologists to improve fungal identification. Copyright © 2017 American Society for Microbiology.

  2. High-Throughput Identification of Bacteria and Yeast by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Conventional Medical Microbiology Laboratories ▿

    Science.gov (United States)

    van Veen, S. Q.; Claas, E. C. J.; Kuijper, Ed J.

    2010-01-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is suitable for high-throughput and rapid diagnostics at low costs and can be considered an alternative for conventional biochemical and molecular identification systems in a conventional microbiological laboratory. First, we evaluated MALDI-TOF MS using 327 clinical isolates previously cultured from patient materials and identified by conventional techniques (Vitek-II, API, and biochemical tests). Discrepancies were analyzed by molecular analysis of the 16S genes. Of 327 isolates, 95.1% were identified correctly to genus level, and 85.6% were identified to species level by MALDI-TOF MS. Second, we performed a prospective validation study, including 980 clinical isolates of bacteria and yeasts. Overall performance of MALDI-TOF MS was significantly better than conventional biochemical systems for correct species identification (92.2% and 83.1%, respectively) and produced fewer incorrect genus identifications (0.1% and 1.6%, respectively). Correct species identification by MALDI-TOF MS was observed in 97.7% of Enterobacteriaceae, 92% of nonfermentative Gram-negative bacteria, 94.3% of staphylococci, 84.8% of streptococci, 84% of a miscellaneous group (mainly Haemophilus, Actinobacillus, Cardiobacterium, Eikenella, and Kingella [HACEK]), and 85.2% of yeasts. MALDI-TOF MS had significantly better performance than conventional methods for species identification of staphylococci and genus identification of bacteria belonging to HACEK group. Misidentifications by MALDI-TOF MS were clearly associated with an absence of sufficient spectra from suitable reference strains in the MALDI-TOF MS database. We conclude that MALDI-TOF MS can be implemented easily for routine identification of bacteria (except for pneumococci and viridans streptococci) and yeasts in a medical microbiological laboratory. PMID:20053859

  3. Comparative proteomic profiles of Aspergillus fumigatus and Aspergillus lentulus strains by surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF-MS

    Directory of Open Access Journals (Sweden)

    Pelloux Hervé

    2011-07-01

    Full Text Available Abstract Background Surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF-MS was applied to analyze the protein profiles in both somatic and metabolic extracts of Aspergillus species. The study was carried out on some Aspergillus species within the Fumigati section (Aspergillus fumigatus wild-types and natural abnormally pigmented mutants, and Aspergillus lentulus. The aim was to validate whether mass spectrometry protein profiles can be used as specific signatures to discriminate different Aspergillus species or even mutants within the same species. Results The growth conditions and the SELDI-TOF parameters were determined to generate characteristic protein profiles of somatic and metabolic extracts of Aspergillus fumigatus strains using five different ProteinChips®, eight growth conditions combining two temperatures, two media and two oxygenation conditions. Nine strains were investigated: three wild-types and four natural abnormally pigmented mutant strains of A. fumigatus and two strains of A. lentulus. A total of 242 fungal extracts were prepared. The spectra obtained are protein signatures linked to the physiological states of fungal strains depending on culture conditions. The best resolutions were obtained using the chromatographic surfaces CM10, NP20 and H50 with fractions of fungi grown on modified Sabouraud medium at 37°C in static condition. Under these conditions, the SELDI-TOF analysis allowed A. fumigatus and A. lentulus strains to be grouped into distinct clusters. Conclusions SELDI-TOF analysis distinguishes A. fumigatus from A. lentulus strains and moreover, permits separate clusters of natural abnormally pigmented A. fumigatus strains to be obtained. In addition, this methodology allowed us to point out fungal components specifically produced by a wild-type strain or natural mutants. It offers attractive potential for further studies of the Aspergillus biology or pathogenesis.

  4. Cost Analysis of Implementing Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Plus Real-Time Antimicrobial Stewardship Intervention for Bloodstream Infections.

    Science.gov (United States)

    Patel, Twisha S; Kaakeh, Rola; Nagel, Jerod L; Newton, Duane W; Stevenson, James G

    2017-01-01

    Studies evaluating rapid diagnostic testing plus stewardship intervention have consistently demonstrated improved clinical outcomes for patients with bloodstream infections. However, the cost of implementing new rapid diagnostic testing can be significant, and such testing usually does not generate additional revenue. There are minimal data evaluating the impact of adding matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for rapid organism identification and dedicating pharmacy stewardship personnel time on the total hospital costs. A cost analysis was performed utilizing patient data generated from the hospital cost accounting system and included additional costs of MALDI-TOF equipment, supplies and personnel, and dedicated pharmacist time for blood culture review and of making interventions to antimicrobial therapy. The cost analysis was performed from a hospital perspective for 3-month blocks before and after implementation of MALDI-TOF plus stewardship intervention. A total of 480 patients with bloodstream infections were included in the analysis: 247 in the preintervention group and 233 in the intervention group. Thirty-day mortality was significantly improved in the intervention group (12% versus 21%, P cost per bloodstream infection was lower in the intervention group ($42,580 versus $45,019). Intensive care unit cost per bloodstream infection accounted for the largest share of the total costs in each group and was also lower in the intervention group ($10,833 versus $13,727). Implementing MALDI-TOF plus stewardship review and intervention decreased mortality for patients with bloodstream infections. Despite the additional costs of implementing MALDI-TOF and of dedicating pharmacy stewardship personnel time to interventions, the total hospital costs decreased by $2,439 per bloodstream infection, for an approximate annual cost savings of $2.34 million. Copyright © 2016 American Society for Microbiology.

  5. Application of Multiplex PCR Coupled with Matrix-Assisted Laser Desorption Ionization-Time of Flight Analysis for Simultaneous Detection of 21 Common Respiratory Viruses.

    Science.gov (United States)

    Zhang, Chi; Xiao, Yan; Du, Jiang; Ren, Lili; Wang, Jianwei; Peng, Junping; Jin, Qi

    2015-08-01

    Respiratory infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory viruses. To compensate for the limits of current respiratory virus detection methods, we developed a 24-plex analysis (common respiratory virus-mass spectrometry [CRV-MS]) that can simultaneously detect and identify 21 common respiratory viruses based on a matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry system. To evaluate the efficacy of the CRV-MS method, we used 102 samples that were confirmed positive for these common respiratory viruses. All tests using the CRV-MS method were effective, with no cross-reactivity observed with other common respiratory viruses. To confirm the usefulness of the CRV-MS method, we screened 336 nasal and throat swabs that were collected from adults or children with suspected viral acute respiratory tract infections using the CRV-MS method and consensus PCR/reverse transcription-PCR (RT-PCR) methods. Excluding four RNase P-negative samples, the CRV-MS and consensus PCR/RT-PCR methods detected respiratory viruses in 92.5% (307/332) and 89.5% (297/332) of the samples, respectively. The two methods yielded identical results for 306 (92.2%) samples, including negative results for 25 samples (7.5%) and positive results for 281 samples (84.6%). Differences between the two methods may reflect their different sensitivities. The CRV-MS method proved to be sensitive and robust, and it can be used in large-scale epidemiological studies of common respiratory virus infections. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Use of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of molds of the Fusarium genus.

    Science.gov (United States)

    Triest, David; Stubbe, Dirk; De Cremer, Koen; Piérard, Denis; Normand, Anne-Cécile; Piarroux, Renaud; Detandt, Monique; Hendrickx, Marijke

    2015-02-01

    The rates of infection with Fusarium molds are increasing, and a diverse number of Fusarium spp. belonging to different species complexes can cause infection. Conventional species identification in the clinical laboratory is time-consuming and prone to errors. We therefore evaluated whether matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a useful alternative. The 289 Fusarium strains from the Belgian Coordinated Collections of Microorganisms (BCCM)/Institute of Hygiene and Epidemiology Mycology (IHEM) culture collection with validated sequence-based identities and comprising 40 species were used in this study. An identification strategy was developed, applying a standardized MALDI-TOF MS assay and an in-house reference spectrum database. In vitro antifungal testing was performed to assess important differences in susceptibility between clinically relevant species/species complexes. We observed that no incorrect species complex identifications were made by MALDI-TOF MS, and 82.8% of the identifications were correct to the species level. This success rate was increased to 91% by lowering the cutoff for identification. Although the identification of the correct species complex member was not always guaranteed, antifungal susceptibility testing showed that discriminating between Fusarium species complexes can be important for treatment but is not necessarily required between members of a species complex. With this perspective, some Fusarium species complexes with closely related members can be considered as a whole, increasing the success rate of correct identifications to 97%. The application of our user-friendly MALDI-TOF MS identification approach resulted in a dramatic improvement in both time and accuracy compared to identification with the conventional method. A proof of principle of our MALDI-TOF MS approach in the clinical setting using recently isolated Fusarium strains demonstrated its validity.

  7. A Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Method for the Identification of Anthraquinones: the Case of Historical Lakes

    Science.gov (United States)

    Sabatini, Francesca; Lluveras-Tenorio, Anna; Degano, Ilaria; Kuckova, Stepanka; Krizova, Iva; Colombini, Maria Perla

    2016-08-01

    This study deals with the identification of anthraquinoid molecular markers in standard dyes, reference lakes, and paint model systems using a micro-invasive and nondestructive technique such as matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry (MALDI-ToF-MS). Red anthraquinoid lakes, such as madder lake, carmine lake, and Indian lac, have been the most widely used for painting purposes since ancient times. From an analytical point of view, identifying lakes in paint samples is challenging and developing methods that maximize the information achievable minimizing the amount of sample needed is of paramount importance. The employed method was tested on less than 0.5 mg of reference samples and required a minimal sample preparation, entailing a hydrofluoric acid extraction. The method is fast and versatile because of the possibility to re-analyze the same sample (once it has been spotted on the steel plate), testing both positive and negative modes in a few minutes. The MALDI mass spectra collected in the two analysis modes were studied and compared with LDI and simulated mass spectra in order to highlight the peculiar behavior of the anthraquinones in the MALDI process. Both ionization modes were assessed for each species. The effect of the different paint binders on dye identification was also evaluated through the analyses of paint model systems. In the end, the method was successful in detecting madder lake in archeological samples from Greek wall paintings and on an Italian funerary clay vessel, demonstrating its capabilities to identify dyes in small amount of highly degraded samples.

  8. Direct demonstration of tissue uptake of an inhaled drug: proof-of-principle study using matrix-assisted laser desorption ionization mass spectrometry imaging.

    Science.gov (United States)

    Fehniger, Thomas E; Végvári, Akos; Rezeli, Melinda; Prikk, Kaiu; Ross, Peeter; Dahlbäck, Magnus; Edula, Goutham; Sepper, Ruth; Marko-Varga, György

    2011-11-01

    Drug therapy is often directed to specific organ and tissue compartments where the mode of action of the compound affects specifically targeted biological processes. However, the direct measurement of drug uptake in terms of a time kinetic and concentrations attained at the local sites has not been readily available as a clinical index for most drugs. A proof-of-principle study was conducted to test the utility of applying matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) to demonstrate the qualitative distribution pattern of a locally administered drug within tissue sites of targeted action. Here we have measured the occurrence of an inhaled bronchodilator, the muscarinic receptor antagonist ipratropium, within human bronchial biopsies obtained by fiber optic bronchoscopy shortly after dosing exposure. Cryo-preserved biopsy samples from five subjects being evaluated for airway obstruction or potential tumor development were prepared as thin frozen sections. Samples coated with a MALDI matrix were analyzed by a MALDI LTQ Orbitrap XL mass spectrometer at large (100 μm) and small (30 μm) raster sizes. Our results demonstrate that ipratropium is rapidly absorbed into the airway wall. Ipratropium parent ion (m/z 332.332) and daughter ions (m/z 166.2 and 290.2) were coincidently partitioned within submucosal spaces containing targeted airway smooth muscle in four out of five subjects. The signal intensity of ipratropium fragment ions provided estimates that local drug concentrations between 3 and 80 nM were achieved within the airway wall. To our knowledge, this is the first reported study in applying MALDI-MSI to demonstrate the localization of a drug administered at therapeutic levels. The study highlights the potential benefit of MALDI-MSI to provide important measurements of drug efficacy in clinical settings.

  9. Rapid, simple, and highly sensitive analysis of drugs in biological samples using thin-layer chromatography coupled with matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Kuwayama, Kenji; Tsujikawa, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2012-01-01

    Rapid and precise identification of toxic substances is necessary for urgent diagnosis and treatment of poisoning cases and for establishing the cause of death in postmortem examinations. However, identification of compounds in biological samples using gas chromatography and liquid chromatography coupled with mass spectrometry entails time-consuming and labor-intensive sample preparations. In this study, we examined a simple preparation and highly sensitive analysis of drugs in biological samples such as urine, plasma, and organs using thin-layer chromatography coupled with matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI/MS). When the urine containing 3,4-methylenedioxymethamphetamine (MDMA) without sample dilution was spotted on a thin-layer chromatography (TLC) plate and was analyzed by TLC/MALDI/MS, the detection limit of the MDMA spot was 0.05 ng/spot. The value was the same as that in aqueous solution spotted on a stainless steel plate. All the 11 psychotropic compounds tested (MDMA, 4-hydroxy-3-methoxymethamphetamine, 3,4-methylenedioxyamphetamine, methamphetamine, p-hydroxymethamphetamine, amphetamine, ketamine, caffeine, chlorpromazine, triazolam, and morphine) on a TLC plate were detected at levels of 0.05-5 ng, and the type (layer thickness and fluorescence) of TLC plate did not affect detection sensitivity. In addition, when rat liver homogenate obtained after MDMA administration (10 mg/kg) was spotted on a TLC plate, MDMA and its main metabolites were identified using TLC/MALDI/MS, and the spots on a TLC plate were visualized by MALDI/imaging MS. The total analytical time from spotting of intact biological samples to the output of analytical results was within 30 min. TLC/MALDI/MS enabled rapid, simple, and highly sensitive analysis of drugs from intact biological samples and crude extracts. Accordingly, this method could be applied to rapid drug screening and precise identification of toxic substances in poisoning cases and

  10. Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi

    Science.gov (United States)

    McMullen, Allison R.; Wallace, Meghan A.; Pincus, David H.; Wilkey, Kathy

    2016-01-01

    Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (including Aspergillus amoenus [n = 2] and Aspergillus calidoustus [n = 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%) Aspergillus sp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare. PMID:27225405

  11. Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi.

    Science.gov (United States)

    McMullen, Allison R; Wallace, Meghan A; Pincus, David H; Wilkey, Kathy; Burnham, C A

    2016-08-01

    Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (including Aspergillus amoenus [n = 2] and Aspergillus calidoustus [n = 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%) Aspergillus sp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Development of a rapid and simplified protocol for direct bacterial identification from positive blood cultures by using matrix assisted laser desorption ionization time-of- flight mass spectrometry.

    Science.gov (United States)

    Jakovljev, Aleksandra; Bergh, Kåre

    2015-11-06

    Bloodstream infections represent serious conditions carrying a high mortality and morbidity rate. Rapid identification of microorganisms and prompt institution of adequate antimicrobial therapy is of utmost importance for a successful outcome. Aiming at the development of a rapid, simplified and efficient protocol, we developed and compared two in-house preparatory methods for the direct identification of bacteria from positive blood culture flasks (BD BACTEC FX system) by using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI TOF MS). Both methods employed saponin and distilled water for erythrocyte lysis. In method A the cellular pellet was overlaid with formic acid on the MALDI TOF target plate for protein extraction, whereas in method B the pellet was exposed to formic acid followed by acetonitrile prior to placing on the target plate. Best results were obtained by method A. Direct identification was achieved for 81.9 % and 65.8 % (50.3 % and 26.2 % with scores >2.0) of organisms by method A and method B, respectively. Overall concordance with final identification was 100 % to genus and 97.9 % to species level. By applying a lower cut-off score value, the levels of identification obtained by method A and method B increased to 89.3 % and 77.8 % of organisms (81.9 % and 65.8 % identified with scores >1.7), respectively. Using the lowered score criteria, concordance with final results was obtained for 99.3 % of genus and 96.6 % of species identifications. The reliability of results, rapid performance (approximately 25 min) and applicability of in-house method A have contributed to implementation of this robust and cost-effective method in our laboratory.

  13. Chemical analysis of pharmaceuticals and explosives in fingermarks using matrix-assisted laser desorption ionization/time-of-flight mass spectrometry.

    Science.gov (United States)

    Kaplan-Sandquist, Kimberly; LeBeau, Marc A; Miller, Mark L

    2014-02-01

    Chemical analysis of latent fingermarks, "touch chemistry," has the potential of providing intelligence or forensically relevant information. Matrix-assisted laser desorption ionization/time-of-flight mass spectrometry (MALDI/TOF MS) was used as an analytical platform for obtaining mass spectra and chemical images of target drugs and explosives in fingermark residues following conventional fingerprint development methods and MALDI matrix processing. There were two main purposes of this research: (1) develop effective laboratory methods for detecting drugs and explosives in fingermark residues and (2) determine the feasibility of detecting drugs and explosives after casual contact with pills, powders, and residues. Further, synthetic latent print reference pads were evaluated as mimics of natural fingermark residue to determine if the pads could be used for method development and quality control. The results suggest that artificial amino acid and sebaceous oil residue pads are not suitable to adequately simulate natural fingermark chemistry for MALDI/TOF MS analysis. However, the pads were useful for designing experiments and setting instrumental parameters. Based on the natural fingermark residue experiments, handling whole or broken pills did not transfer sufficient quantities of drugs to allow for definitive detection. Transferring drugs or explosives in the form of powders and residues was successful for preparing analytes for detection after contact with fingers and deposition of fingermark residue. One downfall to handling powders was that the analyte particles were easily spread beyond the original fingermark during development. Analyte particles were confined in the original fingermark when using transfer residues. The MALDI/TOF MS was able to detect procaine, pseudoephedrine, TNT, and RDX from contact residue under laboratory conditions with the integration of conventional fingerprint development methods and MALDI matrix. MALDI/TOF MS is a nondestructive

  14. Efficient Detection of Carbapenemase Activity in Enterobacteriaceae by Matrix-Assisted Laser Desorption Ionization−Time of Flight Mass Spectrometry in Less Than 30 Minutes

    Science.gov (United States)

    Lasserre, Camille; De Saint Martin, Luc; Cuzon, Gaelle; Bogaerts, Pierre; Lamar, Estelle; Glupczynski, Youri; Naas, Thierry

    2015-01-01

    The recognition of carbapenemase-producing Enterobacteriaceae (CPE) isolates is a major laboratory challenge, and their inappropriate or delayed detection may have negative impacts on patient management and on the implementation of infection control measures. We describe here a matrix-assisted laser desorption ionization−time of flight (MALDI-TOF)-based method to detect carbapenemase activity in Enterobacteriaceae. After a 20-min incubation of the isolate with 0.5 mg/ml imipenem at 37°C, supernatants were analyzed by MALDI-TOF in order to identify peaks corresponding to imipenem (300 Da) and an imipenem metabolite (254 Da). A total of 223 strains, 77 CPE (OXA-48 variants, KPC, NDM, VIM, IMI, IMP, and NMC-A) and 146 non-CPE (cephalosporinases, extended-spectrum β-lactamases [ESBLs], and porin defects), were tested and used to calculate a ratio of imipenem hydrolysis: mass spectrometry [MS] ratio = metabolite/(imipenem + metabolite). An MS ratio cutoff was statistically determined to classify strains as carbapenemase producers (MS ratio of ≥0.82). We validated this method first by testing 30 of our 223 isolates (15 CPE and 15 non-CPE) 10 times to calculate an intraclass correlation coefficient (ICC of 0.98), showing the excellent repeatability of the method. Second, 43 strains (25 CPE and 18 non-CPE) different from the 223 strains used to calculate the ratio cutoff were used as external controls and blind tested. They yielded sensitivity and specificity of 100%. The total cost per test is <0.10 U.S. dollars (USD). This easy-to-perform assay is time-saving, cost-efficient, and highly reliable and might be used in any routine laboratory, given the availability of mass spectrometry, to detect CPE. PMID:25926485

  15. Comparison of Vitek Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Versus Conventional Methods in Candida Identification.

    Science.gov (United States)

    Keçeli, Sema Aşkın; Dündar, Devrim; Tamer, Gülden Sönmez

    2016-02-01

    Candida species are generally identified by conventional methods such as germ tube or morphological appearance on corn meal agar, biochemical methods using API kits and molecular biological methods. Alternative to these methods, rapid and accurate identification methods of microorganisms called matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDİ-TOF MS) has recently been described. In this study, Candida identification results by API Candida kit, API 20C AUX kit and identifications on corn meal agar (CMA) are compared with the results obtained on Vitek-MS. All results were confirmed by sequencing internal transcribed spacer (ITS) regions of rDNA. Totally, 97 Candida strains were identified by germ tube test, CMA, API and Vitek-MS. Vitek-MS results were compatible with 74.2 % of API 20C AUX and 81.4 % of CMA results. The difference between the results of API Candida and API 20C AUX was detected. The ratio of discrepancy between Vitek-MS and API 20C AUX was 25.8 %. Candida species mostly identified as C. famata or C. tropicalis by and not compatible with API kits were identified as C. albicans by Vitek-MS. Sixteen Candida species having discrepant results with Vitek-MS, API or CMA were randomly chosen, and ITS sequence analysis was performed. The results of sequencing were compatible 56.2 % with API 20C AUX, 50 % with CMA and 93.7 % with Vitek-MS. When compared with conventional identification methods, MS results are more reliable and rapid for Candida identification. MS system may be used as routine identification method in clinical microbiology laboratories.

  16. Rapid identification of Bacillus anthracis spores in suspicious powder samples by using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Dybwad, Marius; van der Laaken, Anton L; Blatny, Janet Martha; Paauw, Armand

    2013-09-01

    Rapid and reliable identification of Bacillus anthracis spores in suspicious powders is important to mitigate the safety risks and economic burdens associated with such incidents. The aim of this study was to develop and validate a rapid and reliable laboratory-based matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis method for identifying B. anthracis spores in suspicious powder samples. A reference library containing 22 different Bacillus sp. strains or hoax materials was constructed and coupled with a novel classification algorithm and standardized processing protocol for various powder samples. The method's limit of B. anthracis detection was determined to be 2.5 × 10(6) spores, equivalent to a 55-μg sample size of the crudest B. anthracis-containing powder discovered during the 2001 Amerithrax incidents. The end-to-end analysis method was able to successfully discriminate among samples containing B. anthracis spores, closely related Bacillus sp. spores, and commonly encountered hoax materials. No false-positive or -negative classifications of B. anthracis spores were observed, even when the analysis method was challenged with a wide range of other bacterial agents. The robustness of the method was demonstrated by analyzing samples (i) at an external facility using a different MALDI-TOF MS instrument, (ii) using an untrained operator, and (iii) using mixtures of Bacillus sp. spores and hoax materials. Taken together, the observed performance of the analysis method developed demonstrates its potential applicability as a rapid, specific, sensitive, robust, and cost-effective laboratory-based analysis tool for resolving incidents involving suspicious powders in less than 30 min.

  17. Comparison of the Microflex LT and Vitek MS systems for routine identification of bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Martiny, Delphine; Busson, Laurent; Wybo, Ingrid; El Haj, Rachid Ait; Dediste, Anne; Vandenberg, Olivier

    2012-04-01

    This study compared the performance of three matrix-assisted laser desorption ionization-time of flight mass spectrometry systems: Microflex LT (Bruker Daltonics, Bremen, Germany), Vitek MS RUO (Axima Assurance-Saramis database; bioMérieux, Marcy l'Etoile, France), and Vitek MS IVD (bioMérieux). A total of 1,129 isolates, including 1,003 routine isolates, 73 anaerobes, and 53 bacterial enteropathogens, were tested on the Microflex LT and Axima Assurance devices. The spectra were analyzed using three databases: Biotyper (Bruker Daltonics), Saramis, and Vitek MS (bioMérieux). Among the routine isolates requiring identification to the species level (n = 986), 92.7% and 93.2% were correctly identified by the Biotyper and Vitek MS databases, respectively. The Vitek MS database is more specific for the identification of Streptococcus viridans. For the anaerobes, the Biotyper database often identified Fusobacterium isolates to only the genus level, which is of low clinical significance, whereas 20% of the Bacteroides species were not identified or were misidentified by the Vitek MS database. For the enteropathogens, the poor discrimination between Escherichia coli and Shigella explains the high proportion of unidentified organisms. In contrast to the Biotyper database, the Vitek MS database properly discriminated all of the Salmonella entrica serovar Typhi isolates (n = 5). The performance of the Saramis database was globally poorer. In conclusion, for routine procedures, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency. Other factors, including price, work flow, and lab activity, will affect the choice of a system.

  18. Coumarins as new matrices for matrix-assisted laser-desorption/ionization Fourier transform ion cyclotron resonance mass spectrometric analysis of hydrophobic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hang, E-mail: hangwang@sjtu.edu.cn [Instrumental Analysis Center, Shanghai Jiao Tong University, Dongchuan Road 800, Shanghai 200240 (China); Dai, Bona [Instrumental Analysis Center, Shanghai Jiao Tong University, Dongchuan Road 800, Shanghai 200240 (China); Liu, Bin [Key Laboratory of Kidney Disease Pathogenesis and Intervention of Hubei Province, College of Medicine, Hubei Polytechnic University, Huangshi, Hubei 435003 (China); Lu, Han [Department of Anesthesiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine (SJTU-SM), 197, Rui Jin Er Road, Shanghai 200025 (China)

    2015-07-02

    Highlights: • Coumarins were used as new MALDI matrices. • Coumarins were used for MALDI-FT ICR MS detection of hydrophobic compounds. • DCA had improvement in detection sensitivity, stability, selectivity and reproducibility. • DCA was applied to sterols detection in yeast cells. - Abstract: Hydrophobic compounds with hydroxyl, aldehyde or ketone groups are generally difficult to detect using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), because these compounds have low proton affinity and are poorly ionized by MALDI. Herein, coumarins have been used as new matrices for MALDI-MS analysis of a variety of hydrophobic compounds with low ionization efficiency, including steroids, coenzyme Q10, a cyclic lipopeptide and cholesterol oleate. Five coumarins, including coumarin, umbelliferone, esculetin, 7-hydroxycoumarin-3-carboxylic acid (HCA) and 6,7-dihydroxycoumarin-3-carboxylic acid (DCA), were compared with the conventional matrices of 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA). Coumarins with hydroxyl or carboxylic acid groups enabled detection. Taking DCA as an example, this matrix proved to be superior to DHB or CHCA in detection sensitivity, stability, spot-to-spot and sample-to-sample reproducibility, and accuracy. DCA increased the stability of the target compounds and decreased the loss of water. The [M + Na]{sup +} peaks were observed for all target compounds by adding NaCl as an additive, and the [M − H{sub 2}O + H]{sup +} and [M + H]{sup +} peaks decreased. DCA was selected for the identification of sterols in yeast cells, and thirteen sterols were detected by Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry. This work demonstrates the potential of DCA as a new matrix for detection of hydrophobic molecules by MALDI-MS and provides an alternative tool for screening sterols in antifungal research.

  19. A Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Method for the Identification of Anthraquinones: the Case of Historical Lakes

    Science.gov (United States)

    Sabatini, Francesca; Lluveras-Tenorio, Anna; Degano, Ilaria; Kuckova, Stepanka; Krizova, Iva; Colombini, Maria Perla

    2016-11-01

    This study deals with the identification of anthraquinoid molecular markers in standard dyes, reference lakes, and paint model systems using a micro-invasive and nondestructive technique such as matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry (MALDI-ToF-MS). Red anthraquinoid lakes, such as madder lake, carmine lake, and Indian lac, have been the most widely used for painting purposes since ancient times. From an analytical point of view, identifying lakes in paint samples is challenging and developing methods that maximize the information achievable minimizing the amount of sample needed is of paramount importance. The employed method was tested on less than 0.5 mg of reference samples and required a minimal sample preparation, entailing a hydrofluoric acid extraction. The method is fast and versatile because of the possibility to re-analyze the same sample (once it has been spotted on the steel plate), testing both positive and negative modes in a few minutes. The MALDI mass spectra collected in the two analysis modes were studied and compared with LDI and simulated mass spectra in order to highlight the peculiar behavior of the anthraquinones in the MALDI process. Both ionization modes were assessed for each species. The effect of the different paint binders on dye identification was also evaluated through the analyses of paint model systems. In the end, the method was successful in detecting madder lake in archeological samples from Greek wall paintings and on an Italian funerary clay vessel, demonstrating its capabilities to identify dyes in small amount of highly degraded samples.

  20. The use of matrix-assisted laser desorption ionization-time of flight mass spectrometry in the identification of Francisella tularensis

    Science.gov (United States)

    Karatuna, Onur; Çelebi, Bekir; Can, Simge; Akyar, Işın; Kiliç, Selçuk

    2016-01-01

    Francisella tularensis is the cause of the zoonotic disease tularemia and is classified among highly pathogenic bacteria (HPB) due to its low infection dose and potential for airborne transmission. In the case of HBP, there is a pressing need for rapid, accurate and reliable identification. Phenotypic identification of Francisella species is inappropriate for clinical microbiology laboratories because it is time-consuming, hazardous and subject to variable interpretation. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was recently evaluated as a useful tool for the rapid identification of a variety of microorganisms. In this study, we evaluated the use of MALDI-TOF MS for the rapid identification of Francisella tularensis and differentiation of its subspecies. Using national collection of Francisella isolates from the National Tularemia Reference Laboratory (Public Health Institution of Turkey, Ankara), a total of 75 clinical isolates were investigated by species and subspecies-specific polymerase chain reaction (PCR) test and MALDI-TOF MS. All isolates were originally identified as F. tularensis subsp. holarctica according to region of difference 1 (RD1) subspecies-specific PCR results. For all isolates MALDI-TOF MS provided results in concordance with subspecies-specific PCR analysis. Although PCR-based methods are effective in identifying Francisella species, they are labor-intensive and take longer periods of time to obtain the results when compared with MALDI-TOF MS. MALDI-TOF MS appeared to be a rapid, reliable and cost-effective identification technique for Francisella spp. Shorter analysis time and low cost make this an appealing new option in microbiology laboratories. PMID:26773181

  1. Comparison of the Vitek MS and Bruker Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Systems for Identification of Rhodococcus equi and Dietzia spp.

    Science.gov (United States)

    de Alegría Puig, Carlos Ruiz; Pilares, Lilian; Marco, Francesc; Vila, Jordi; Martínez-Martínez, Luis; Navas, Jesús

    2017-07-01

    Rhodococcus equi causes pyogranulomatous pneumonia in domesticated animals and immunocompromised humans. Dietzia spp. are environmental bacteria that have rarely been associated with human infections. R. equi and Dietzia spp. are closely related actinomycetes. Phenotypic discrimination between R. equi and Dietzia on the basis of their Gram stain morphology and colony appearance is problematic. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a fast, reliable, and cost-effective method for identification of a wide variety of microorganisms. We have evaluated the performance of Bruker Biotyper versus that of Vitek MS for identification of a collection of 154 isolates identified at the source as R. equi that includes isolates belonging to the genus Dietzia PCR amplification of the choE gene, encoding a cholesterol oxidase, and 16S rRNA sequencing were considered the reference methods for R. equi identification. Biotyper identified 131 (85.1%) of the 154 isolates at the species level, and this figure increased to 152 (98.7%) when the species cutoff was reduced from a score of ≥2.000 to ≥1.750. Vitek MS correctly identified at the species level 130 (84.4%) isolates as long as bacteria were extracted with ethanol but only 35 (22.7%) isolates when samples were prepared by direct extraction from colonies. The two systems allowed differentiation between R. equi and Dietzia spp., but identification of all Dietzia sp. isolates at the species level needed sequencing of the 16S rRNA gene. Copyright © 2017 American Society for Microbiology.

  2. Interfacing droplet microfluidics with matrix-assisted laser desorption/ionization mass spectrometry: label-free content analysis of single droplets.

    Science.gov (United States)

    Küster, Simon K; Fagerer, Stephan R; Verboket, Pascal E; Eyer, Klaus; Jefimovs, Konstantins; Zenobi, Renato; Dittrich, Petra S

    2013-02-05

    Droplet-based microfluidic systems have become a very powerful tool to miniaturize chemical and biological reactions. However, droplet content analysis remains challenging and relies almost exclusively on optical methods such as fluorescence spectroscopy. Hence, labeling of the analyte is typically required which impedes a more universal applicability of microdroplets. Here we present a novel interface coupling droplet microfluidics and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for label-free content analysis of single droplets. Nanoliter aqueous droplets immersed in perfluorinated oil are created in a microfluidic T-junction, transferred into a capillary, and deposited on a high-density microarray MALDI plate mounted on a motorized xy-stage. The fully automated system is robust and reliable due to two unique features. First, a simple optical droplet detection system is used to synchronize stage movement and exit of droplets from the capillary. Second, the microarray plate contains an array of over 26,000 hydrophilic spots within a hydrophobic coating, each spot acting as a recipient to confine the droplets and to prevent cross-contamination. The MALDI matrix can also be applied using our system by spotting matrix droplets on the microarray in a separate run. To demonstrate the potential of our system, we studied the enzymatic cleavage of angiotensin I by angiotensin converting enzyme and monitored the increasing concentration of the product angiotensin II over time. The interface provides a robust and fully automated method for rapid label-free and information-rich content analysis of single droplets. With the high number of droplets per plate, this method is particularly suitable for high-throughput screening applications.

  3. Rapid detection of enterobacteriaceae producing extended spectrum beta-lactamases directly from positive blood cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Oviaño, M; Fernández, B; Fernández, A; Barba, M J; Mouriño, C; Bou, G

    2014-11-01

    Bacteria that produce extended-spectrum β-lactamases (ESBLs) are an increasing healthcare problem and their rapid detection is a challenge that must be overcome in order to optimize antimicrobial treatment and patient care. Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has been used to determine resistance to β-lactams, including carbapenems in Enterobacteriaceae, but the methodology has not been fully validated as it remains time-consuming. We aimed to assess whether MALDI-TOF can be used to detect ESBL-producing Enterobacteriaceae from positive blood culture bottles in clinical practice. In the assay, 141 blood cultures were tested, 13 of them were real bacteraemias and 128 corresponded to blood culture bottles seeded with bacterial clinical isolates. Bacteraemias were analysed by MALDI-TOF after a positive growth result and the 128 remaining blood cultures 24 h after the bacterial seeding. β-lactamase activity was determined through the profile of peaks associated with the antibiotics cefotaxime and ceftazidime and its hydrolyzed forms. Clavulanic acid was added to rule out the presence of non-ESBL mechanisms. Overall data show a 99% (103 out of 104) sensitivity in detecting ESBL in positive blood cultures. Data were obtained in 90 min (maximum 150 min). The proposed methodology has a great impact on the early detection of ESBL-producing Enterobacteriaceae from positive blood cultures, being a rapid and efficient method and allowing early administration of an appropriate antibiotic therapy.

  4. Rapid Identification of microbes in positive blood cultures by use of the vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system.

    Science.gov (United States)

    Foster, Arnold G W

    2013-11-01

    Sepsis is a major cause of death worldwide among nonhospitalized people and hospitalized patients. A wide range of pathogens are involved, and the correct identification and correct antimicrobial therapy are critical to ensure optimal clinical outcomes. With the recent introduction of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS), rapid identification of bacteria and fungi is now possible. The purpose of this study was to develop a rapid technique for identifying organisms in positive blood cultures using the Vitek MS system (bioMérieux). This technique is a lysis centrifugation method which involves a four-step washing and centrifugation procedure. A total of 253 positive monomicrobial blood cultures (Bactec Plus aerobic, anaerobic, and pediatric bottles) were tested using the Vitek MS system (KnowledgeBase version 2.0), with 92.1% and 88.1% of organisms overall being identified to the genus level and the species level, respectively. Of 161 Gram-positive bacterial isolates, 95.7% and 90.1% were identified to the genus level and the species level, respectively; of 92 Gram-negative bacterial isolates, 84.7% and 83.7% were identified to the genus level and the species level, respectively. The results obtained using this method demonstrate that the Vitek MS system can be used for rapid and effective identification of bacteria from positive blood cultures within 30 to 45 min after the positive signal has been provided by the Bactec FX blood culture system (Becton, Dickinson). This will lead to faster administration of the appropriate antimicrobial therapy and increase the chances for optimal clinical outcomes for patients.

  5. Rapid detection of carbapenem resistance in Acinetobacter baumannii using matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Marie Kempf

    Full Text Available Rapid detection of carbapenem-resistant Acinetobacter baumannii strains is critical and will benefit patient care by optimizing antibiotic therapies and preventing outbreaks. Herein we describe the development and successful application of a mass spectrometry profile generated by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF that utilized the imipenem antibiotic for the detection of carbapenem resistance in a large series of A. baumannii clinical isolates from France and Algeria. A total of 106 A. baumannii strains including 63 well-characterized carbapenemase-producing and 43 non-carbapenemase-producing strains, as well as 43 control strains (7 carbapenem-resistant and 36 carbapenem-sensitive strains were studied. After an incubation of bacteria with imipenem for up to 4 h, the mixture was centrifuged and the supernatant analyzed by MALDI-TOF MS. The presence and absence of peaks representing imipenem and its natural metabolite was analyzed. The result was interpreted as positive for carbapenemase production if the specific peak for imipenem at 300.0 m/z disappeared during the incubation time and if the peak of the natural metabolite at 254.0 m/z increased as measured by the area under the curves leading to a ratio between the peak for imipenem and its metabolite being <0.5. This assay, which was applied to the large series of A. baumannii clinical isolates, showed a sensitivity of 100.0% and a specificity of 100.0%. Our study is the first to demonstrate that this quick and simple assay can be used as a routine tool as a point-of-care method for the identification of A. baumannii carbapenemase-producers in an effort to prevent outbreaks and the spread of uncontrollable superbugs.

  6. Rapid Detection of Carbapenem Resistance in Acinetobacter baumannii Using Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry

    Science.gov (United States)

    Flaudrops, Christophe; Berrazeg, Meryem; Brunel, Jean-Michel; Drissi, Mourad; Mesli, Esma; Touati, Abdelaziz; Rolain, Jean-Marc

    2012-01-01

    Rapid detection of carbapenem-resistant Acinetobacter baumannii strains is critical and will benefit patient care by optimizing antibiotic therapies and preventing outbreaks. Herein we describe the development and successful application of a mass spectrometry profile generated by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) that utilized the imipenem antibiotic for the detection of carbapenem resistance in a large series of A. baumannii clinical isolates from France and Algeria. A total of 106 A. baumannii strains including 63 well-characterized carbapenemase-producing and 43 non-carbapenemase-producing strains, as well as 43 control strains (7 carbapenem-resistant and 36 carbapenem-sensitive strains) were studied. After an incubation of bacteria with imipenem for up to 4 h, the mixture was centrifuged and the supernatant analyzed by MALDI-TOF MS. The presence and absence of peaks representing imipenem and its natural metabolite was analyzed. The result was interpreted as positive for carbapenemase production if the specific peak for imipenem at 300.0 m/z disappeared during the incubation time and if the peak of the natural metabolite at 254.0 m/z increased as measured by the area under the curves leading to a ratio between the peak for imipenem and its metabolite being <0.5. This assay, which was applied to the large series of A. baumannii clinical isolates, showed a sensitivity of 100.0% and a specificity of 100.0%. Our study is the first to demonstrate that this quick and simple assay can be used as a routine tool as a point-of-care method for the identification of A. baumannii carbapenemase-producers in an effort to prevent outbreaks and the spread of uncontrollable superbugs. PMID:22359616

  7. Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for species identification of Acinetobacter strains isolated from blood cultures.

    Science.gov (United States)

    Kishii, K; Kikuchi, K; Matsuda, N; Yoshida, A; Okuzumi, K; Uetera, Y; Yasuhara, H; Moriya, K

    2014-05-01

    The clinical relevance of Acinetobacter species, other than A. baumannii, as human pathogens has not been sufficiently assessed owing to the insufficiency of simple phenotypic clinical diagnostic laboratory tests. Infections caused by these organisms have different impacts on clinical outcome and require different treatment and management approaches. It is therefore important to correctly identify Acinetobacter species. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been introduced to identify a wide range of microorganisms in clinical laboratories, but only a few studies have examined its utility for identifying Acinetobacter species, particularly those of the non-Acinetobacter baumannii complex. We therefore evaluated MALDI-TOF MS for identification of Acinetobacter species by comparing it with sequence analysis of rpoB using 123 isolates of Acinetobacter species from blood. Of the isolates examined, we identified 106/123 (86.2%) to species, and 16/123 (13.0%) could only be identified as acinetobacters. The identity of one isolate could not be established. Of the 106 species identified, 89/106 (84.0%) were confirmed by rpoB sequence analysis, and 17/106 (16.0%) were discordant. These data indicate correct identification of 89/123 (72.4%) isolates. Surprisingly, all blood culture isolates were identified as 13 species of Acinetobacter, and the incidence of Acinetobacter pittii was unexpectedly high (42/123; 34.1%) and exceeded that of A. baumannii (22/123; 17.9%). Although the present identification rate using MALDI-TOF MS is not acceptable for species-level identification of Acinetobacter, further expansion of the database should remedy this situation.

  8. Identification of rare pathogenic bacteria in a clinical microbiology laboratory: impact of matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Seng, Piseth; Abat, Cedric; Rolain, Jean Marc; Colson, Philippe; Lagier, Jean-Christophe; Gouriet, Frédérique; Fournier, Pierre Edouard; Drancourt, Michel; La Scola, Bernard; Raoult, Didier

    2013-07-01

    During the past 5 years, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has become a powerful tool for routine identification in many clinical laboratories. We analyzed our 11-year experience in routine identification of clinical isolates (40 months using MALDI-TOF MS and 91 months using conventional phenotypic identification [CPI]). Among the 286,842 clonal isolates, 284,899 isolates of 459 species were identified. The remaining 1,951 isolates were misidentified and required confirmation using a second phenotypic identification for 670 isolates and using a molecular technique for 1,273 isolates of 339 species. MALDI-TOF MS annually identified 112 species, i.e., 36 species/10,000 isolates, compared to 44 species, i.e., 19 species/10,000 isolates, for CPI. Only 50 isolates required second phenotypic identifications during the MALDI-TOF MS period (i.e., 4.5 reidentifications/10,000 isolates) compared with 620 isolates during the CPI period (i.e., 35.2/10,000 isolates). We identified 128 bacterial species rarely reported as human pathogens, including 48 using phenotypic techniques (22 using CPI and 37 using MALDI-TOF MS). Another 75 rare species were identified using molecular methods. MALDI-TOF MS reduced the time required for identification by 55-fold and 169-fold and the cost by 5-fold and 96-fold compared with CPI and gene sequencing, respectively. MALDI-TOF MS was a powerful tool not only for routine bacterial identification but also for identification of rare bacterial species implicated in human infectious diseases. The ability to rapidly identify bacterial species rarely described as pathogens in specific clinical specimens will help us to study the clinical burden resulting from the emergence of these species as human pathogens, and MALDI-TOF MS may be considered an alternative to molecular methods in clinical laboratories.

  9. Identification of Enterobacteriaceae by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using the VITEK MS system.

    Science.gov (United States)

    Richter, S S; Sercia, L; Branda, J A; Burnham, C-A D; Bythrow, M; Ferraro, M J; Garner, O B; Ginocchio, C C; Jennemann, R; Lewinski, M A; Manji, R; Mochon, A B; Rychert, J A; Westblade, L F; Procop, G W

    2013-12-01

    This multicenter study evaluated the accuracy of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry identifications from the VITEK MS system (bioMérieux, Marcy l'Etoile, France) for Enterobacteriaceae typically encountered in the clinical laboratory. Enterobacteriaceae isolates (n = 965) representing 17 genera and 40 species were analyzed on the VITEK MS system (database v2.0), in accordance with the manufacturer's instructions. Colony growth (≤72 h) was applied directly to the target slide. Matrix solution (α-cyano-4-hydroxycinnamic acid) was added and allowed to dry before mass spectrometry analysis. On the basis of the confidence level, the VITEK MS system provided a species, genus only, or no identification for each isolate. The accuracy of the mass spectrometric identification was compared to 16S rRNA gene sequencing performed at MIDI Labs (Newark, DE). Supplemental phenotypic testing was performed at bioMérieux when necessary. The VITEK MS result agreed with the reference method identification for 96.7% of the 965 isolates tested, with 83.8% correct to the species level and 12.8% limited to a genus-level identification. There was no identification for 1.7% of the isolates. The VITEK MS system misidentified 7 isolates (0.7 %) as different genera. Three Pantoea agglomerans isolates were misidentified as Enterobacter spp. and single isolates of Enterobacter cancerogenus, Escherichia hermannii, Hafnia alvei, and Raoultella ornithinolytica were misidentified as Klebsiella oxytoca, Citrobacter koseri, Obesumbacterium proteus, and Enterobacter aerogenes, respectively. Eight isolates (0.8 %) were misidentified as a different species in the correct genus. The VITEK MS system provides reliable mass spectrometric identifications for Enterobacteriaceae.

  10. Identification of serum proteins discriminating colorectal cancer patients and healthy controls using surface-enhanced laser desorption ionisation-time of flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Judith YMN Engwegen; Helgi H Helgason; Annemieke Cats; Nathan Harris; Johannes MG Bonfrer; Jan HM Schellens; Jos H Beijnen

    2006-01-01

    AIM: To detect the new serum biomarkers for colorectal cancer (CRC) by serum protein profiling with surfaceenhanced laser desorption ionisation - time of flight mass spectrometry (SELDI-TOF MS).METHODS: Two independent serum sample sets were analysed separately with the ProteinChip technology (set A: 40 CRC + 49 healthy controls; set B: 37 CRC + 31 healthy controls), using chips with a weak cation exchange moiety and buffer pH 5. Discriminative power of differentially expressed proteins was assessed with a classification tree algorithm. Sensitivities and specificities of the generated classification trees were obtained by blindly applying data from set A to the generated trees from set B and vice versa. CRC serum protein profiles were also compared with those from breast, ovarian,prostate, and non-small cell lung cancer.RESULTS: Mass-to-charge ratios (m/z) 3.1×103, 3.3×103, 4.5×103, 6.6×103 and 28×103 were used as classifiers in the best-performing classification trees. Tree sensitivities and specificities were between 65% and 90%.Most of these discriminative m/z values were also different in the other tumour types investigated. M/z 3.3×103, main classifier in most trees, was a doubly charged form of the 6.6×103-Da protein. The latter was identified as apolipoprotein C-I. M/z 3.1×103 was identified as an N-terminal fragment of albumin, and m/z 28×103 as apolipoprotein A-I.CONCLUSION: SELDI-TOF MS followed by classification tree pattern analysis is a suitable technique for finding new serum markers for CRC. Biomarkers can be identified and reproducibly detected in independent sample sets with high sensitivities and specificities. Although not specific for CRC, these biomarkers have a potential role in disease and treatment monitoring.

  11. Identification of Haemophilus influenzae Type b Isolates by Use of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

    Science.gov (United States)

    Månsson, Viktor; Kostrzewa, Markus; Nilson, Bo; Riesbeck, Kristian

    2015-01-01

    Haemophilus influenzae type b (Hib) is, in contrast to non-type b H. influenzae, associated with severe invasive disease, such as meningitis and epiglottitis, in small children. To date, accurate H. influenzae capsule typing requires PCR, a time-consuming and cumbersome method. Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) provides rapid bacterial diagnostics and is increasingly used in clinical microbiology laboratories. Here, MALDI-TOF MS was evaluated as a novel approach to separate Hib from other H. influenzae. PCR-verified Hib and non-Hib reference isolates were selected based on genetic and spectral characteristics. Mass spectra of reference isolates were acquired and used to generate different classification algorithms for Hib/non-Hib differentiation using both ClinProTools and the MALDI Biotyper software. A test series of mass spectra from 33 Hib and 77 non-Hib isolates, all characterized by PCR, was used to evaluate the algorithms. Several algorithms yielded good results, but the two best were a ClinProTools model based on 22 separating peaks and subtyping main spectra (MSPs) using MALDI Biotyper. The ClinProTools model had a sensitivity of 100% and a specificity of 99%, and the results were 98% reproducible using a different MALDI-TOF MS instrument. The Biotyper subtyping MSPs had a sensitivity of 97%, a specificity of 100%, and 93% reproducibility. Our results suggest that it is possible to use MALDI-TOF MS to differentiate Hib from other H. influenzae. This is a promising method for rapidly identifying Hib in unvaccinated populations and for the screening and surveillance of Hib carriage in vaccinated populations. PMID:25926500

  12. Study on the plasma proteomic profiling by using surface enhanced laser desorption ionization time of flight mass spectrometry for setting up a diagnostic model of endometriosis

    Institute of Scientific and Technical Information of China (English)

    Liu Hai-yuan; Liu Chun-yan; Leng Jin-hua; Liu Zhu-feng; Sun Da-wei; Zhu Lan; Lang Jing-he; Zheng Yan-hua; Zhang Jian-zhong

    2007-01-01

    Objective: To determine the plasma proteomic profiling by using surface enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF-MS) combined with bioinformatics for screening biomarkers of endometriosis and primarily setting up a diagnostic model of endometriosis.Method.Thirty-six patients with endometriosis diagnosed laparoscopically and thirty-five healthy controls were included in the study.Their serum were analyzed by SELDI and protein chip to generate protein profiling spectra.Student t test was used to compare the peak intensifies of the protein profiling results from the different groups.Biomarker Pattern Software was used to analyze the data between two groups and set up a diagnostic model for endometriosis.Protein profiling spectra from sixteen endometriosis patients and fifteen healthy controls were used double-blindedly to test the efficiency of the diagnostic model and generate the sensitivity and specificity of the model.Result: Fourteen abnormally expressed protein peaks were detected in the plasma of patients with endometriosis (P<0.01).The endometriosis diagnostic model was composed of three protein peaks.It correctly identified 33 of 36 patients with endometriosis and 29 of 35 controls in the training test.In the masked set 14 of 16 patients with endometriosis and 12 of 15 normal controls were correctly identified with sensitivity of 87.5% and specificity of 8o%.Conclusion: Patients with endometriosis have a unique cluster of proteins in plasma detected by SELDI.SELDI provides a new approach for screening novel biomarkers of endometriosis.Its utility in clinical practice need further study.

  13. Identification of Haemophilus influenzae Type b Isolates by Use of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Månsson, Viktor; Resman, Fredrik; Kostrzewa, Markus; Nilson, Bo; Riesbeck, Kristian

    2015-07-01

    Haemophilus influenzae type b (Hib) is, in contrast to non-type b H. influenzae, associated with severe invasive disease, such as meningitis and epiglottitis, in small children. To date, accurate H. influenzae capsule typing requires PCR, a time-consuming and cumbersome method. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) provides rapid bacterial diagnostics and is increasingly used in clinical microbiology laboratories. Here, MALDI-TOF MS was evaluated as a novel approach to separate Hib from other H. influenzae. PCR-verified Hib and non-Hib reference isolates were selected based on genetic and spectral characteristics. Mass spectra of reference isolates were acquired and used to generate different classification algorithms for Hib/non-Hib differentiation using both ClinProTools and the MALDI Biotyper software. A test series of mass spectra from 33 Hib and 77 non-Hib isolates, all characterized by PCR, was used to evaluate the algorithms. Several algorithms yielded good results, but the two best were a ClinProTools model based on 22 separating peaks and subtyping main spectra (MSPs) using MALDI Biotyper. The ClinProTools model had a sensitivity of 100% and a specificity of 99%, and the results were 98% reproducible using a different MALDI-TOF MS instrument. The Biotyper subtyping MSPs had a sensitivity of 97%, a specificity of 100%, and 93% reproducibility. Our results suggest that it is possible to use MALDI-TOF MS to differentiate Hib from other H. influenzae. This is a promising method for rapidly identifying Hib in unvaccinated populations and for the screening and surveillance of Hib carriage in vaccinated populations.

  14. Use of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of Molds of the Fusarium Genus

    Science.gov (United States)

    Stubbe, Dirk; De Cremer, Koen; Piérard, Denis; Normand, Anne-Cécile; Piarroux, Renaud; Detandt, Monique; Hendrickx, Marijke

    2014-01-01

    The rates of infection with Fusarium molds are increasing, and a diverse number of Fusarium spp. belonging to different species complexes can cause infection. Conventional species identification in the clinical laboratory is time-consuming and prone to errors. We therefore evaluated whether matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is a useful alternative. The 289 Fusarium strains from the Belgian Coordinated Collections of Microorganisms (BCCM)/Institute of Hygiene and Epidemiology Mycology (IHEM) culture collection with validated sequence-based identities and comprising 40 species were used in this study. An identification strategy was developed, applying a standardized MALDI-TOF MS assay and an in-house reference spectrum database. In vitro antifungal testing was performed to assess important differences in susceptibility between clinically relevant species/species complexes. We observed that no incorrect species complex identifications were made by MALDI-TOF MS, and 82.8% of the identifications were correct to the species level. This success rate was increased to 91% by lowering the cutoff for identification. Although the identification of the correct species complex member was not always guaranteed, antifungal susceptibility testing showed that discriminating between Fusarium species complexes can be important for treatment but is not necessarily required between members of a species complex. With this perspective, some Fusarium species complexes with closely related members can be considered as a whole, increasing the success rate of correct identifications to 97%. The application of our user-friendly MALDI-TOF MS identification approach resulted in a dramatic improvement in both time and accuracy compared to identification with the conventional method. A proof of principle of our MALDI-TOF MS approach in the clinical setting using recently isolated Fusarium strains demonstrated its validity. PMID:25411180

  15. High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories.

    Science.gov (United States)

    van Veen, S Q; Claas, E C J; Kuijper, Ed J

    2010-03-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is suitable for high-throughput and rapid diagnostics at low costs and can be considered an alternative for conventional biochemical and molecular identification systems in a conventional microbiological laboratory. First, we evaluated MALDI-TOF MS using 327 clinical isolates previously cultured from patient materials and identified by conventional techniques (Vitek-II, API, and biochemical tests). Discrepancies were analyzed by molecular analysis of the 16S genes. Of 327 isolates, 95.1% were identified correctly to genus level, and 85.6% were identified to species level by MALDI-TOF MS. Second, we performed a prospective validation study, including 980 clinical isolates of bacteria and yeasts. Overall performance of MALDI-TOF MS was significantly better than conventional biochemical systems for correct species identification (92.2% and 83.1%, respectively) and produced fewer incorrect genus identifications (0.1% and 1.6%, respectively). Correct species identification by MALDI-TOF MS was observed in 97.7% of Enterobacteriaceae, 92% of nonfermentative Gram-negative bacteria, 94.3% of staphylococci, 84.8% of streptococci, 84% of a miscellaneous group (mainly Haemophilus, Actinobacillus, Cardiobacterium, Eikenella, and Kingella [HACEK]), and 85.2% of yeasts. MALDI-TOF MS had significantly better performance than conventional methods for species identification of staphylococci and genus identification of bacteria belonging to HACEK group. Misidentifications by MALDI-TOF MS were clearly associated with an absence of sufficient spectra from suitable reference strains in the MALDI-TOF MS database. We conclude that MALDI-TOF MS can be implemented easily for routine identification of bacteria (except for pneumococci and viridans streptococci) and yeasts in a medical microbiological laboratory.

  16. Performances of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for rapid identification of bacteria in routine clinical microbiology.

    Science.gov (United States)

    Dubois, Damien; Grare, Marion; Prere, Marie-Françoise; Segonds, Christine; Marty, Nicole; Oswald, Eric

    2012-08-01

    Rapid and cost-effective matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based systems will replace conventional phenotypic methods for routine identification of bacteria. We report here the first evaluation of the new MALDI-TOF MS-based Vitek MS system in a large clinical microbiology laboratory. This system uses an original spectrum classifier algorithm and a specific database designed for the identification of clinically relevant species. We have tested 767 routine clinical isolates representative of 50 genera and 124 species. Vitek MS-based identifications were performed by means of a single deposit on a MALDI disposable target without any prior extraction step and compared with reference identifications obtained mainly with the VITEK2 phenotypic system; if the identifications were discordant, molecular techniques provided reference identifications. The Vitek MS system provided 96.2% correct identifications to the species level (86.7%), to the genus level (8.2%), or within a range of species belonging to different genera (1.3%). Conversely, 1.3% of isolates were misidentified and 2.5% were unidentified, partly because the species was not included in the database; a second deposit provided a successful identification for 0.8% of isolates unidentified with the first deposit. The Vitek MS system is a simple, convenient, and accurate method for routine bacterial identification with a single deposit, considering the high bacterial diversity studied and as evidenced by the low prevalence of species without correct identification. In addition to a second deposit in uncommon cases, expanding the spectral database is expected to further enhance performances.

  17. 4-Chloro-α-cyanocinnamic acid is an efficient soft matrix for cyanocobalamin detection in foodstuffs by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS).

    Science.gov (United States)

    Calvano, Cosima Damiana; Ventura, Giovanni; Palmisano, Francesco; Cataldi, Tommaso R I

    2016-09-01

    4-Chloro-α-cyanocinnamic acid (ClCCA) is a very useful matrix able to give the protonated adduct [M+H](+) of intact cyanocobalamin (CNCbl) as the base peak (m/z 1355.58) in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The only fragment observed is [M-CN + H](+•) formed through the facile (•) CN neutral loss reflecting the fairly low Co-C bond energy. All other investigated proton transfer matrices, including α-cyano-4-hydroxycinnamic acid, para-nitroaniline and 2,5-dihydroxybenzoic acid, give rise to a complete decyanation of CNCbl with concomitant formation of [M-CN + H](+•) , [M-CN + Na](+•) and [M-CN + K](+•) adducts at m/z 1329.57, 1351.55 and 1367.51, respectively. Depending on the matrix used, a variable degree of fragmentation involving the α-side axial ligand was observed. A plausible explanation of the specific behaviour of 4-chloro-α-cyanocinnamic acid as a soft matrix is discussed. Tandem mass spectra of both [M + H](+) and [M-CN + H](+•) ions were obtained and product ions successfully assigned. The possibility of detecting the protonated adduct of intact CNCbl was exploited in foodstuff samples such as cow milk and hen egg yolk by MALDI tandem MS upon sample extraction. We believe that our data provide strong basis for the application of MALDI tandem MS in the qualitative analysis of natural CNCbl, including fish, liver and meat samples. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Analysis of methicillin-resistant Staphylococcus aureus major clonal lineages by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Zhang, Tingting; Ding, Jinya; Rao, Xiancai; Yu, Jingbo; Chu, Meiling; Ren, Wei; Wang, Lu; Xue, Wencheng

    2015-10-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important pathogen associated with nosocomial infections in many countries. Multilocus sequence typing (MLST) is one of the genetic typing methods used to type MRSA with a high discriminatory power, however, it is labor-intensive, timely, and costly. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) coupled with ClinProTools is a potential tool to discover biomarker peaks and to generate a classification model based on highly sophisticated mathematical algorithms to discriminate clonal lineages. We investigated the performance of MALDI-TOF MS for discriminating 154 MRSA-ST239, 72 MRSA-ST5, 30 MRSA-ST59, 14 MRSA-ST45, and 20 MRSA-OST (other clonal lineages). Our results indicate that the model construction and validation have good potency to discriminate ST45 from other lineages with a sensitivity and a specificity of both 100%, and a sensitivity of 95.80% and a specificity of 94.62% to identify ST239. For Biotyper classification, the sensitivity and specificity were more than of 90% for ST239, ST59 and ST45, whereas only 81.94% sensitivity for ST5. By single-peak analysis, the peaks m/z 4808 and 9614 can correctly discriminate ST45 a sensitivity and a specificity of both 100%; the peak m/z 6554 can also discriminate ST239 with a sensitivity of 91.9% and a specificity of 85.4%. In conclusion, MALDI-TOF MS coupled with ClinProTools has a high detection performance for MRSA typing with obvious advantages of being rapid, highly accurate, and being a low cost in comparison with MLST.

  19. Analysis of metal-binding proteins separated by non-denaturating gel electrophoresis using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS).

    Science.gov (United States)

    Becker, J Susanne; Mounicou, Sandra; Zoriy, Miroslav V; Becker, J Sabine; Lobinski, Ryszard

    2008-09-15

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) have become established as very efficient and sensitive biopolymer and elemental mass spectrometric techniques for studying metal-binding proteins (metalloproteins) in life sciences. Protein complexes present in rat tissues (liver and kidney) were separated in their native state in the first dimension by blue native gel electrophoresis (BN-PAGE). Essential and toxic metals, such as zinc, copper, iron, nickel, chromium, cadmium and lead, were detected by scanning the gel bands using quadrupole LA-ICP-MS with and without collision cell as a microanalytical technique. Several proteins were identified by using MALDI-TOF-MS together with a database search. For example, on one protein band cut from the BN-PAGE gel and digested with the enzyme trypsin, two different proteins - protein FAM44B and cathepsin B precursor - were identified. By combining biomolecular and elemental mass spectrometry, it was possible to characterize and identify selected metal-binding rat liver and kidney tissue proteins.

  20. Matrix-free UV-laser desorption/ionization (LDI) mass spectrometric imaging at the single-cell level: distribution of secondary metabolites of Arabidopsis thaliana and Hypericum species.

    Science.gov (United States)

    Hölscher, Dirk; Shroff, Rohit; Knop, Katrin; Gottschaldt, Michael; Crecelius, Anna; Schneider, Bernd; Heckel, David G; Schubert, Ulrich S; Svatos, Ales

    2009-12-01

    The present paper describes matrix-free laser desorption/ionisation mass spectrometric imaging (LDI-MSI) of highly localized UV-absorbing secondary metabolites in plant tissues at single-cell resolution. The scope and limitations of the method are discussed with regard to plants of the genus Hypericum. Naphthodianthrones such as hypericin and pseudohypericin are traceable in dark glands on Hypericum leaves, placenta, stamens and styli; biflavonoids are also traceable in the pollen of this important phytomedical plant. The highest spatial resolution achieved, 10 microm, was much higher than that achieved by commonly used matrix-assisted laser desorption/ionization (MALDI) imaging protocols. The data from imaging experiments were supported by independent LDI-TOF/MS analysis of cryo-sectioned, laser-microdissected and freshly cut plant material. The results confirmed the suitability of combining laser microdissection (LMD) and LDI-TOF/MS or LDI-MSI to analyse localized plant secondary metabolites. Furthermore, Arabidopsis thaliana was analysed to demonstrate the feasibility of LDI-MSI for other commonly occurring compounds such as flavonoids. The organ-specific distribution of kaempferol, quercetin and isorhamnetin, and their glycosides, was imaged at the cellular level.