WorldWideScience

Sample records for laser based diagnostics

  1. Laser-based techniques for combustion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, N.

    1997-04-01

    Two-photon-induced Degenerate Four-Wave Mixing, DFWM, was applied for the first time to the detection of CO, and NH{sub 3} molecules. Measurements were performed in a cell, and in atmospheric-pressure flames. In the cell measurements, the signal dependence on the pressure and on the laser beam intensity was studied. The possibility of simultaneous detection of NH{sub 3} and OH was investigated. Carbon monoxide and ammonia were also detected employing two-photon-induced Polarization Spectroscopy, PS. In the measurements performed in a cold gas flow, the signal strength dependence on the laser intensity, and on the polarization of the pump beam, was investigated. An approach to improve the spatial resolution of the Amplified Stimulated Emission, ASE, was developed. In this approach, two laser beams at different frequencies were crossed in the sample. If the sum of the frequencies of the two laser beams matches a two photon resonance of the investigated species, only the molecules in the intersection volume will be excited. NH{sub 3} molecules and C atoms were studied. The potential of using two-photon LIF for two-dimensional imaging of combustion species was investigated. Although LIF is species specific, several species can be detected simultaneously by utilizing spectral coincidences. Combining one- and two-photon process, OH, NO, and O were detected simultaneously, as well as OH, NO, and NH{sub 3}. Collisional quenching is the major source of uncertainty in quantitative applications of LIF. A technique for two-dimensional, absolute species concentration measurements, circumventing the problems associated with collisional quenching, was developed. By applying simple mathematics to the ratio of two LIF signals generated from two counterpropagating laser beams, the absolute species concentration could be obtained. 41 refs

  2. Nuclear based diagnostics in high-power laser applications

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc; Sonnabend, Kerstin; Harres, Knut; Otten, Anke; Roth, Markus [TU Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Vogt, Karsten; Bagnoud, Vincent [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany)

    2010-07-01

    High-power lasers allow focused intensities of >10{sup 18} W/cm{sup 2}. During the laser-solid interaction, an intense relativistic electron current is injected from the plasma into the target. One challenge is to characterize the electron dynamic close to the interaction region. Moreover, next generation high-power laser proton acceleration leads to high proton fluxes, which require novel, nuclear diagnostic techniques. We present an activation-based nuclear pyrometry for the investigation of electrons generated in relativistic laser-solid interactions. We use novel activation targets consisting of several isotopes with different photo-neutron disintegration thresholds. The electrons are decelerated inside the target via bremsstrahlung processes. The high-energy bremsstrahlung induces photo-nuclear reactions. In this energy range no disturbing low energy effects are important. Via the pyrometry the Reconstruction of the absolute yield, spectral and spatial distribution of the electrons is possible. For the characterization of proton beams we present a nuclear activation imaging spectroscopy (NAIS). The diagnostic is based on proton-neutron disintegration reactions of copper stacked in consecutive layers. An autoradiography of copper layers leads to spectrally and spatially reconstruction of the beam profile.

  3. Beam Diagnostics for Laser Undulator Based on Compton Backward Scattering

    CERN Document Server

    Kuroda, R

    2005-01-01

    A compact soft X-ray source is required in various research fields such as material and biological science. The laser undulator based on Compton backward scattering has been developed as a compact soft X-ray source for the biological observation at Waseda University. It is performed in a water window region (250eV - 500 eV) using the interaction between 1047 nm Nd:YLF laser (10ps FWHM) and about 5 MeV high quality electron beam (10ps FWHM) generated from rf gun system. The range of X-ray energy in the water window region has K-shell absorption edges of Oxygen, Carbon and Nitrogen, which mainly constitute of living body. Since the absorption coefficient of water is much smaller than the protein's coefficient in this range, a dehydration of the specimens is not necessary. To generate the soft X-ray pulse stably, the electron beam diagnostics have been developed such as the emittance measurement using double slit scan technique, the bunch length measurement using two frequency analysis technique. In this confere...

  4. Laser Diagnostics for Reacting Flows

    National Research Council Canada - National Science Library

    Hanson, Ronald K

    2007-01-01

    ... (UV) or infrared (IR) wavelengths. The cw lasers were spectrally narrow, allowing study of innovative diagnostics based on spectral lineshapes, while the pulsed lasers provided intense bursts of photons needed for techniques based on LIF...

  5. Plasma Channel Diagnostic Based on Laser Centroid Oscillations

    International Nuclear Information System (INIS)

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2010-01-01

    A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. The centroid position of low-intensity ( 14 Wcm -2 ) laser pulses focused at the input of a hydrogen-filled capillary discharge waveguide was scanned and the exit positions recorded to determine the channel shape and depth with an accuracy of a few %. In addition, accurate alignment of the laser beam through the plasma channel can be provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.

  6. Laser-based diagnostics on NO in a diesel engine

    International Nuclear Information System (INIS)

    Brugman, T.M.

    1999-01-01

    The non-intrusive two-dimensional detection of nitric oxide (NO) in the cylinder of a diesel engine by means of laser-induced fluorescence (LIF) is the central theme of this thesis. Chapter 1 provides a general introduction including a brief discussion of the underlying environmental considerations as well as an overview of the laser-based imaging diagnostics in i.c. engines as reported in the literature. In the same chapter the LIF spectroscopy of NO is discussed in detail and the dependence of the LIF signal to several parameters is studied on the basis of a two-level rate equation model. This chapter concludes with an overview of the imaging techniques used in the experiments discussed in this thesis. The principal components of the experimental setup are described in great detail in chapter 2. Some of the issues discussed there have turned out to be crucial for the success of the experiments as reported in the subsequent chapters. In chapter 3 the results of the first imaging experiments in the idling engine are reported for two different fuels: n-heptane and standard diesel fuel. Besides the in-cylinder NO fluorescence distributions at various crank angles presented in this chapter, excitation spectra recorded from in-cylinder NO at atmospheric pressure using the respective fuels are also reported. In chapter 4 the detection method is further validated on the basis of a number of experiments in the standard-diesel -fuel -driven engine testing the various underlying assumptions. The sensitivity of the LIF signal to photo-chemically- induced effects possibly arising from the use of a high-power UV excimer laser, is investigated by means of a double-resonance experiment. The dependence of the LIF signal on the actual laser power is experimentally verified as well. The degree as to which saturation might occur at the in-cylinder laser intensities pertinent to this work, is estimated using data and relations found in the literature. Finally, in this chapter image

  7. A Laser-Based Diagnostic Suite for Hypersonic Test Facilities, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR effort, Los Gatos Research (LGR) proposes to develop a suite of laser-based diagnostics for the study of reactive and non-reactive hypersonic flows....

  8. Laser-Based Diagnostic Measurements of Low Emissions Combustor Concepts

    Science.gov (United States)

    Hicks, Yolanda R.

    2011-01-01

    This presentation provides a summary of primarily laser-based measurement techniques we use at NASA Glenn Research Center to characterize fuel injection, fuel/air mixing, and combustion. The report highlights using Planar Laser-Induced Fluorescence, Particle Image Velocimetry, and Phase Doppler Interferometry to obtain fuel injector patternation, fuel and air velocities, and fuel drop sizes and turbulence intensities during combustion. We also present a brief comparison between combustors burning standard JP-8 Jet fuel and an alternative fuels. For this comparison, we used flame chemiluminescence and high speed imaging.

  9. Optically-Based Diagnostics for Gas-Phase Laser Development

    Science.gov (United States)

    2010-08-01

    Laser (COIL), Electric Oxygen Iodine Laser (EOIL), Diode-Pumped Alkali Laser (DPAL), and Exciplex Alkali Laser (XPAL). The papers at this Symposium... exciplex -assisted absorption and laser-induced fluorescence, and multi-photon excitation of infrared atomic alkali transitions.11,12 In this paper... EXCIPLEX LASER SYSTEMS Proper review and discussion of the DPAL and XPAL laser systems can be found elsewhere,11,12 and in the paper by Carroll and

  10. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  11. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  12. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  13. Lanthanide-based laser-induced phosphorescence for spray diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Voort, D. D. van der, E-mail: d.d.v.d.voort@tue.nl; Water, W. van de; Kunnen, R. P. J.; Clercx, H. J. H.; Heijst, G. J. F. van [Applied Physics Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Maes, N. C. J.; Sweep, A. M.; Dam, N. J. [Mechanical Engineering Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Lamberts, T. [Institute of Theoretical Chemistry, University of Stuttgart, D-70569 Stuttgart (Germany)

    2016-03-15

    Laser-induced phosphorescence (LIP) is a relatively recent and versatile development for studying flow dynamics. This work investigates certain lanthanide-based molecular complexes for their use in LIP for high-speed sprays. Lanthanide complexes in solutions have been shown to possess long phosphorescence lifetimes (∼1-2 ms) and to emit light in the visible wavelength range. In particular, europium and terbium complexes are investigated using fluorescence/phosphorescence spectrometry, showing that europium-thenoyltrifluoracetone-trioctylphosphineoxide (Eu-TTA-TOPO) can be easily and efficiently excited using a standard frequency-tripled Nd:YAG laser. The emitted spectrum, with maximum intensity at a wavelength of 614 nm, is shown not to vary strongly with temperature (293-383 K). The decay constant of the phosphorescence, while independent of ambient pressure, decreases by approximately 12 μs/K between 323 and 373 K, with the base level of the decay constant dependent on the used solvent. The complex does not luminesce in the gas or solid state, meaning only the liquid phase is visualized, even in an evaporating spray. By using an internally excited spray containing the phosphorescent complex, the effect of vaporization is shown through the decrease in measured intensity over the length of the spray, together with droplet size measurements using interferometric particle imaging. This study shows that LIP, using the Eu-TTA-TOPO complex, can be used with different solvents, including diesel surrogates. Furthermore, it can be easily handled and used in sprays to investigate spray breakup and evaporation.

  14. Endoscopic Laser-Based 3D Imaging for Functional Voice Diagnostics

    Directory of Open Access Journals (Sweden)

    Marion Semmler

    2017-06-01

    Full Text Available Recently, we reported on the in vivo application of a miniaturized measuring device for 3D visualization of the superior vocal fold vibrations from high-speed recordings in combination with a laser projection unit (LPU. As a long-term vision for this proof of principle, we strive to integrate the further developed laserendoscopy as a diagnostic method in daily clinical routine. The new LPU mainly comprises a Nd:YAG laser source (532 nm/CW/2 ω and a diffractive optical element (DOE generating a regular laser grid (31 × 31 laser points that is projected on the vocal folds. By means of stereo triangulation, the 3D coordinates of the laser points are reconstructed from the endoscopic high-speed footage. The new design of the laserendoscope constitutes a compromise between robust image processing and laser safety regulations. The algorithms for calibration and analysis are now optimized with respect to their overall duration and the number of required interactions, which is objectively assessed using binary classifiers. The sensitivity and specificity of the calibration procedure are increased by 40.1% and 22.3%, which is statistically significant. The overall duration for the laser point detection is reduced by 41.9%. The suggested semi-automatic reconstruction software represents an important stepping-stone towards potential real time processing and a comprehensive, objective diagnostic tool of evidence-based medicine.

  15. Time of Flight based diagnostics for high energy laser driven ion beams

    Science.gov (United States)

    Scuderi, V.; Milluzzo, G.; Alejo, A.; Amico, A. G.; Booth, N.; Cirrone, G. A. P.; Doria, D.; Green, J.; Kar, S.; Larosa, G.; Leanza, R.; Margarone, D.; McKenna, P.; Padda, H.; Petringa, G.; Pipek, J.; Romagnani, L.; Romano, F.; Schillaci, F.; Borghesi, M.; Cuttone, G.; Korn, G.

    2017-03-01

    Nowadays the innovative high power laser-based ion acceleration technique is one of the most interesting challenges in particle acceleration field, showing attractive characteristics for future multidisciplinary applications, including medical ones. Nevertheless, peculiarities of optically accelerated ion beams make mandatory the development of proper transport, selection and diagnostics devices in order to deliver stable and controlled ion beams for multidisciplinary applications. This is the main purpose of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) beamline that will be realized and installed within 2018 at the ELI-Beamlines research center in the Czech Republic, where laser driven high energy ions, up to 60 MeV/n, will be available for users. In particular, a crucial role will be played by the on-line diagnostics system, recently developed in collaboration with INFN-LNS (Italy), consisting of TOF detectors, placed along the beamline (at different detection distances) to provide online monitoring of key characteristics of delivered beams, such as energy, fluence and ion species. In this contribution an overview on the ELIMAIA available ion diagnostics will be briefly given along with the preliminary results obtained during a test performed with high energy laser-driven proton beams accelerated at the VULCAN PW-laser available at RAL facility (U.K.).

  16. Time of Flight based diagnostics for high energy laser driven ion beams

    International Nuclear Information System (INIS)

    Scuderi, V.; Margarone, D.; Schillaci, F.; Milluzzo, G.; Amico, A.G.; Cirrone, G.A.P.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Alejo, A.; Doria, D.; Kar, S.; Borghesi, M.; Booth, N.; Green, J.; McKenna, P.; Padda, H.; Romagnani, L.

    2017-01-01

    Nowadays the innovative high power laser-based ion acceleration technique is one of the most interesting challenges in particle acceleration field, showing attractive characteristics for future multidisciplinary applications, including medical ones. Nevertheless, peculiarities of optically accelerated ion beams make mandatory the development of proper transport, selection and diagnostics devices in order to deliver stable and controlled ion beams for multidisciplinary applications. This is the main purpose of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) beamline that will be realized and installed within 2018 at the ELI-Beamlines research center in the Czech Republic, where laser driven high energy ions, up to 60 MeV/n, will be available for users. In particular, a crucial role will be played by the on-line diagnostics system, recently developed in collaboration with INFN-LNS (Italy), consisting of TOF detectors, placed along the beamline (at different detection distances) to provide online monitoring of key characteristics of delivered beams, such as energy, fluence and ion species. In this contribution an overview on the ELIMAIA available ion diagnostics will be briefly given along with the preliminary results obtained during a test performed with high energy laser-driven proton beams accelerated at the VULCAN PW-laser available at RAL facility (U.K.).

  17. Non-invasive diagnostics of the maxillary and frontal sinuses based on diode laser gas spectroscopy.

    Science.gov (United States)

    Lewander, Märta; Lindberg, Sven; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune

    2012-03-01

    Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.

  18. Error tolerance analysis of wave diagnostic based on coherent modulation imaging in high power laser system

    Science.gov (United States)

    Pan, Xingchen; Liu, Cheng; Zhu, Jianqiang

    2018-02-01

    Coherent modulation imaging providing fast convergence speed and high resolution with single diffraction pattern is a promising technique to satisfy the urgent demands for on-line multiple parameter diagnostics with single setup in high power laser facilities (HPLF). However, the influence of noise on the final calculated parameters concerned has not been investigated yet. According to a series of simulations with twenty different sampling beams generated based on the practical parameters and performance of HPLF, the quantitative analysis based on statistical results was first investigated after considering five different error sources. We found the background noise of detector and high quantization error will seriously affect the final accuracy and different parameters have different sensitivity to different noise sources. The simulation results and the corresponding analysis provide the potential directions to further improve the final accuracy of parameter diagnostics which is critically important to its formal applications in the daily routines of HPLF.

  19. Development of Laser Based Plasma Diagnostics for Fusion Research on NSTX-U

    Science.gov (United States)

    Barchfeld, Robert Adam

    plasma diagnostics. Plasma diagnostics collect data from fusion reactors in a number of different ways. Among these are far infrared (FIR) laser based systems. By probing a fusion plasma with FIR lasers, many properties can be measured, such as density and density fluctuations. This dissertation discusses the theory and design of two laser based diagnostic instruments: 1) the Far Infrared Tangential Interferometer and Polarimeter (FIReTIP) systems, and 2) the High-ktheta Scattering System. Both of these systems have been designed and fabricated at UC Davis for use on the National Spherical Torus Experiment - Upgrade (NSTX-U), located at Princeton Plasma Physics Laboratory (PPPL). These systems will aid PPPL scientists in fusion research. The FIReTIP system uses 119 ?m methanol lasers to pass through the plasma core to measure a chord averaged plasma density through interferometry. It can also measure the toroidal magnetic field strength by the way of polarimetery. The High-ktheta Scattering System uses a 693 GHz formic acid laser to measure electron scale turbulence. Through collective Thomson scattering, as the probe beam passes through the plasma, collective electron motion will scatter power to a receiver with the angle determined by the turbulence wavenumber. This diagnostic will measure ktheta from 7 to 40 cm-1 with a 4-channel receiver array. The High-ktheta Scattering system was designed to facilitate research on electron temperature gradient (ETG) modes, which are believed to be a major contributor to anomalous transport on NSTX-U. The design and testing of these plasma diagnostics are described in detail. There are a broad range of components detailed including: optically pumped gas FIR lasers, overmoded low loss waveguide, launching and receiving optical designs, quasi-optical mixers, electronics, and monitoring and control systems. Additionally, details are provided for laser maintenance, alignment techniques, and the fundamentals of nano-CNC-machining.

  20. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  1. Laser diagnostics for picosecond e-beams

    International Nuclear Information System (INIS)

    Pogorelsky, I.; Ben-Zvi, I.

    1992-01-01

    We propose a novel approach to picosecond e-bunch/laser pulse synchronization and spatial alignment based upon refraction and reflection of a laser beam on a plasma column created by relativistic electrons traveling through a gas or solid optical material. The technique may be used in laser accelerators and for general subpicosecond e-beam diagnostics

  2. Laser-aided plasma diagnostics

    NARCIS (Netherlands)

    Donne, A. J. H.; Barth, C. J.

    2008-01-01

    This paper will focus on two types of laser-aided diagnostics: Thomson scattering and laser-induced fluorescence. Thomson scattering is a very powerful diagnostic, which is applied at nearly every magnetic confinement device. Depending on the experimental conditions different plasma parameters can

  3. Novel Infiltration Diagnostics based on Laser-line Scanning and Infrared Temperature Field Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinwei [Iowa State Univ., Ames, IA (United States)

    2017-12-08

    This project targets the building energy efficiency problems induced by building infiltration/leaks. The current infiltration inspection techniques often require extensive visual inspection and/or whole building pressure test. These current techniques cannot meet more than three of the below five criteria of ideal infiltration diagnostics: 1. location and extent diagnostics, 2. building-level application, 3. least surface preparation, 4. weather-proof, and 5. non-disruption to building occupants. These techniques are either too expensive or time consuming, and often lack accuracy and repeatability. They are hardly applicable to facades/facades section. The goal of the project was to develop a novel infiltration diagnostics technology based on laser line-scanning and simultaneous infrared temperature imaging. A laboratory scale experimental setup was designed to mimic a model house of well-defined pressure difference below or above the outside pressure. Algorithms and Matlab-based programs had been developed for recognition of the hole location in infrared images. Our experiment based on laser wavelengths of 450 and 1550 nm and laser beam diameters of 4-25 mm showed that the location of the holes could be identified using laser heating; the diagnostic approach however could not readily distinguish between infiltration and non-infiltration points. To significantly improve the scanning throughput and recognition accuracy, a second approach was explored, developed, and extensively tested. It incorporates a liquid spray on the surface to induce extra phase change cooling effect. In this spray method, we termed it as PECIT (Phase-change Enhanced Cooling Infrared Thermography), phase-change enhanced cooling was used, which significantly amplifies the effect of air flow (infiltration and exfiltration). This heat transfer method worked extremely well to identify infiltration and exfiltration locations with high accuracy and increased throughput. The PECIT technique was

  4. Infrared laser diagnostics for ITER

    International Nuclear Information System (INIS)

    Hutchinson, D.P.; Richards, R.K.; Ma, C.H.

    1995-01-01

    Two infrared laser-based diagnostics are under development at ORNL for measurements on burning plasmas such as ITER. The primary effort is the development of a CO 2 laser Thomson scattering diagnostic for the measurement of the velocity distribution of confined fusion-product alpha particles. Key components of the system include a high-power, single-mode CO 2 pulsed laser, an efficient optics system for beam transport and a multichannel low-noise infrared heterodyne receiver. A successful proof-of-principle experiment has been performed on the Advanced Toroidal Facility (ATF) stellerator at ORNL utilizing scattering from electron plasma frequency satellites. The diagnostic system is currently being installed on Alcator C-Mod at MIT for measurements of the fast ion tail produced by ICRH heating. A second diagnostic under development at ORNL is an infrared polarimeter for Faraday rotation measurements in future fusion experiments. A preliminary feasibility study of a CO 2 laser tangential viewing polarimeter for measuring electron density profiles in ITER has been completed. For ITER plasma parameters and a polarimeter wavelength of 10.6 microm, a Faraday rotation of up to 26 degree is predicted. An electro-optic polarization modulation technique has been developed at ORNL. Laboratory tests of this polarimeter demonstrated a sensitivity of ≤ 0.01 degree. Because of the similarity in the expected Faraday rotation in ITER and Alcator C-Mod, a collaboration between ORNL and the MIT Plasma Fusion Center has been undertaken to test this polarimeter system on Alcator C-Mod. A 10.6 microm polarimeter for this measurement has been constructed and integrated into the existing C-Mod multichannel two-color interferometer. With present experimental parameters for C-Mod, the predicted Faraday rotation was on the order of 0.1 degree. Significant output signals were observed during preliminary tests. Further experiment and detailed analyses are under way

  5. Wavefront Measurement for Laser-Guiding Diagnostic

    International Nuclear Information System (INIS)

    Shiraishi, S.; Gonsalves, A.J.; Lin, C.; Nakamura, K.; Osterhoff, J.; Sokollik, T.; van Tilborg, J.; Geddes, C.G.R.; Schroeder, C.B.; Toth, Cs.; Esarey, E.; Leemans, W.P.

    2010-01-01

    The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogenfilled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

  6. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry.

    Science.gov (United States)

    Serafini, S; Paone, N; Castellini, P

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  7. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  8. Pulsed Blue and Ultraviolet Laser System for Fluorescence Diagnostics based on Nonlinear Frequency Conversion

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay

    The motivation for the current thesis work is to build a compact, efficient, pulsed, diode-pumped solid-state (DPSS) laser at 340 nm to be used for autofluorescence imaging and related cancer diagnostic experiments. By exciting endogenous fluorophores in the UV spectrum, autofluorescence imaging...... ns. Comparing this to the 9 ns relative jitter achieved in the passive system shows the performance penalty incurred in using the passive approach. Lastly, practical applications of compact semiconductor and DPSS lasers in the blue and UV spectral region are presented. A CW tapered diode at 808 nm...... applied to other wavelengths; specifically, those in the blue and UV spectral region. Using the passive synchronization technique and the optimization procedure reported for quasi-three-level lasers, a new generation of high peak power, pulsed, blue and UV laser light sources could be realized....

  9. Ultrafast Laser Diagnostics for Energetic-Material Ignition Mechanisms: Tools for Physics-Based Model Development.

    Energy Technology Data Exchange (ETDEWEB)

    Kearney, Sean Patrick; Jilek, Brook Anton; Kohl, Ian Thomas; Farrow, Darcie; Urayama, Junji

    2014-11-01

    We present the results of an LDRD project to develop diagnostics to perform fundamental measurements of material properties during shock compression of condensed phase materials at micron spatial scales and picosecond time scales. The report is structured into three main chapters, which each focus on a different diagnostic devel opment effort. Direct picosecond laser drive is used to introduce shock waves into thin films of energetic and inert materials. The resulting laser - driven shock properties are probed via Ultrafast Time Domain Interferometry (UTDI), which can additionally be used to generate shock Hugoniot data in tabletop experiments. Stimulated Raman scattering (SRS) is developed as a temperature diagnostic. A transient absorption spectroscopy setup has been developed to probe shock - induced changes during shock compressio n. UTDI results are presented under dynamic, direct - laser - drive conditions and shock Hugoniots are estimated for inert polystyrene samples and for the explosive hexanitroazobenzene, with results from both Sandia and Lawrence Livermore presented here. SRS a nd transient absorption diagnostics are demonstrated on static thin - film samples, and paths forward to dynamic experiments are presented.

  10. Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems

    Science.gov (United States)

    Esenaliev, Rinat O.

    2017-09-01

    Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels.

  11. Development of laser-based technology for the routine first wall diagnostic on the tokamak EAST: LIBS and LIAS

    Science.gov (United States)

    Hu, Z.; Gierse, N.; Li, C.; Liu, P.; Zhao, D.; Sun, L.; Oelmann, J.; Nicolai, D.; Wu, D.; Wu, J.; Mao, H.; Ding, F.; Brezinsek, S.; Liang, Y.; Ding, H.; Luo, G.; Linsmeier, C.; EAST Team

    2017-12-01

    A laser based method combined with spectroscopy, such as laser-induced breakdown spectroscopy (LIBS) and laser-induced ablation spectroscopy (LIAS), is a promising technology for plasma-wall interaction studies. In this work, we report the development of in situ laser-based diagnostics (LIBS and LIAS) for the assessment of static and dynamic fuel retention on the first wall without removing the tiles between and during plasma discharges in the Experimental Advanced Superconducting Tokamak (EAST). The fuel retention on the first wall was measured after different wall conditioning methods and daily plasma discharges by in situ LIBS. The result indicates that the LIBS can be a useful tool to predict the wall condition in EAST. With the successful commissioning of a refined timing system for LIAS, an in situ approach to investigate fuel retention is proposed.

  12. CW Laser radar for combustion diagnostics

    Directory of Open Access Journals (Sweden)

    Malmqvist Elin

    2018-01-01

    Full Text Available A CW-laser radar system developed for combustion diagnostics is described. The system is based on triangulation to attain range information. A portable system has been constructed and here we show some result from measurements in various flames, for example Rayleigh scattering thermometry and monitoring of particle distributions with high temporal and spatial resolution. The concept can equally well be based on pulsed lasers, allowing suppression of background emission through gated detection.

  13. Spectroscopic and imaging diagnostics of pulsed laser deposition laser plasmas

    International Nuclear Information System (INIS)

    Thareja, Raj K.

    2002-01-01

    An overview of laser spectroscopic techniques used in the diagnostics of laser ablated plumes used for thin film deposition is given. An emerging laser spectroscopic imaging technique for the laser ablation material processing is discussed. (author)

  14. Laser Diagnostics for Reacting Flows

    Science.gov (United States)

    2010-01-11

    the high-temperature kinetics of n-heptane pyrolysis . The two-wavelength temperature and vapor concentration diagnostic designed for n- dodecane was...features ranging from 1338 nm to 1469 nm and one laser tuned to a CO2 transition near 1997 nm were combined onto a single mode optical fiber ( Corning

  15. Novel Nonlinear Laser Diagnostic Techniques

    Science.gov (United States)

    1993-07-01

    a thermometric probe of reactive flows. Since the two-photon pump laser couples a Doppler broadened ground state velocity distribution to the excited...rism, and passed unfocused into an aluminum cell con- in frequency space. Regions for line fitting are found by taining 99% pure NO. The gas mixture...of ASE as a More recently, ASE has prompted interest as an thermometric probe of combustion environments optical diagnostic of combustion environments

  16. A pilot study using laser-based technique for non-invasive diagnostics of hypertensive conditions in mice

    Science.gov (United States)

    Litvinova, Karina S.; Ahmad, Shakil; Wang, Keqing; Rafailov, Ilya E.; Sokolovski, Sergei G.; Zhang, Lin; Rafailov, Edik U.; Ahmed, Asif

    2016-02-01

    Endothelial dysfunction is directly linked to preeclampsia, a maternal hypertensive condition that is life threating for both the mother and the baby. Epidemiological studies show that women with a history of pre-eclampsia have an elevated risk for cardiovascular disease. Here we report a new non-invasive diagnostic test for preeclampsia in mice that allows us to non-invasively assess the condition of the animals during the experiment and treatment in established models of preeclampsia. A laser-based multifunctional diagnostics system (LAKK-M) was chosen to carry out non-invasive analysis of multiple parameters. The device was used to simultaneously record the microcirculatory blood flow and oxygen saturation, as well as fluorescence levels of endogenous fluorophores. Preliminary experiments were conducted on adenoviral (Ad-)- mediated overexpression of sFlt-1 (Ad-sFlt-1) to mimic preeclampsialike symptoms in mice. The recorded data displayed the ability of the LAKK-M diagnostics device to detect significant differences in perfusion measurements between the control and Ad-sFlt-1 treatment. Preliminary results provide a potential avenue to employ these diagnostics technology to monitor and aid in maintaining control of live animal conditions throughout the experiment and treatment.

  17. Copper laser diagnostics and kinetics support

    International Nuclear Information System (INIS)

    1981-12-01

    In the effort MSNW participated with the LINL copper-Vapor Laser Program by providing a useful plasma diagnostic for interpretation of Copper-vapor laser kinetics. MSNW developed and delivered a pulsed interferometric diagnostic package to LLNL. Moreover MSNW provided personal services at the request and direction of LLL in the implementation of the diagnostic and interpretation of the data

  18. Combustion & Laser Diagnostics Research Complex (CLDRC)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The Combustion and Laser Diagnostics Research Complex (CLRDC) supports the experimental and computational study of fundamental combustion phenomena to...

  19. Laser based beam diagnostic for the RAL Front End Test Stand (FETS)

    International Nuclear Information System (INIS)

    Gabor, C.; Lee, D. A.; Pozimski, J. K.; Letchford, A.

    2007-01-01

    For the diagnostic of high power particle beams, non-destructive measurement devices provide minimum influence on the beam and avoid various problems in connection with the high power density on surfaces. An H- ion beam offers the opportunity of non destructive beam diagnostics based on the effect of photo detachment. By the interaction of light with H- ions, the additional electron can be detached and a small number of neutrals will be produced. An additional magnetic dipole field can then be used to separate the detached electrons and neutrals from the ions. Using an integral detector the spatial distribution of the beam ion density can be derived, while the use of a spatial resolving detector enables to determine the phase space distribution. To investigate the measurement principle of the latter, a test stand was set up at the IAP in Frankfurt. This system will now be adopted to the requirements of the Front End Test Stand at CCLRC/ RAL. The aim of this FETS is to demonstrate a chopped H- beam of 60mA at 3MeV and 50pps with sufficiently high beam quality. The paper will present a detailed description of the proposed set up at RAL and discuss several results of simulations and experimental data gained in Frankfurt

  20. Laser beam diagnostics for kilowatt power pulsed YAG laser

    International Nuclear Information System (INIS)

    Liu, Yi; Leong, Keng H.

    1992-01-01

    There is a growing need for high power YAG laser beam diagnostics with the recent introduction of such lasers in laser material processing. In this paper, we will describe the use of a commercially available laser beam analyzer (Prometec) to profile the laser beam from a 1600 W pulsed Nd:YAG laser that has a 1 mm fiber optic beam delivery system. The selection of laser pulse frequency and pulse width for the measurement is discussed. Laser beam propagation parameters by various optical components such as fibers and lenses can be determined from measurements using this device. The importance of such measurements will be discussed

  1. Laser diagnostics of materials and chemistry

    International Nuclear Information System (INIS)

    Hartford, A. Jr.

    1984-01-01

    Several examples are given of the ability of laser-based diagnostic techniques to make noninvasive measurements in hostile environments. Using coherent anti-Stokes Raman scattering both majority and minority species concentrations, as well as temperature, have been measured in the hot, high-pressure, particle-laden stream of a coal gasifier. In addition, numerous toxic and corrosive elements in the gasifier stream have been identified, but not yet quantified. In addition to providing the capability for making analytical determinations, laser techniques have been extensively employed to measure the rates of elementary chemical reactions. Recently, the temperature regime over which such meaurements are possible has been expanded. Although much of the laser diagnostic activity to date has involved investigations of the gas phase, significant information concerning heterogeneous phenomena can still be inferred. For instance, gas-solid reactions can manifest themselves as changes in vapor phase composition. Furthermore, in the future we expect expanded studies involving reactions of refractory metals (both atoms and clusters) and additional investigations of processes occurring at interfaces and on surfaces

  2. Charge Diagnostics for Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, K.; Gonsalves, A.J.; Lin, C.; Sokollik, T.; Smith, A.; Rodgers, D.; Donahue, R.; Bryne, W.; Leemans, W.P.

    2010-01-01

    The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1percent per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm2 and 0.4 pC/ps/mm2, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within +/-10 percent.

  3. Charge Diagnostics for Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, K.; Gonsalves, A. J.; Lin, C.; Sokollik, T.; Smith, A.; Rodgers, D.; Donahue, R.; Bryne, W.; Leemans, W. P.

    2010-01-01

    The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1% per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm 2 and 0.4 pC/ps/mm 2 , respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within ±10%.

  4. 2017 Laser Diagnostics in Combustion GRC/GRS

    Science.gov (United States)

    2017-10-06

    scientists and engineers . The goal of GRC was to bring together scientists and engineers with a strong interest in laser-based combustion diagnostics to...processes. The GRS, held the weekend before the GRC, was organized to bring together emerging leaders in the field at an early stage in their careers ...coupled multi-scale combustion processes. The GRC on Laser Diagnostics in Combustion was designed to bring together scientists and engineers working at

  5. Diagnostics of laser-produced plasmas

    Directory of Open Access Journals (Sweden)

    Batani Dimitri

    2016-12-01

    Full Text Available We present the general challenges of plasma diagnostics for laser-produced plasmas and give a few more detailed examples: spherically bent crystals for X-ray imaging, velocity interferometers (VISAR for shock studies, and proton radiography.

  6. Primer on laser scattering diagnostics

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1978-07-01

    The theory of laser scattering is presented in abbreviated format, with emphasis on physical interpretation, followed by sections on laser sources, practical considerations in designing experiments, and current developments in extending the techniques to multispace and multitime point measurements

  7. Diagnostics of laser ablated plasma plumes

    DEFF Research Database (Denmark)

    Amoruso, S.; Toftmann, B.; Schou, Jørgen

    2004-01-01

    The effect of an ambient gas on the expansion dynamics of laser ablated plasmas has been studied for two systems by exploiting different diagnostic techniques. First, the dynamics of a MgB2 laser produced plasma plume in an Ar atmosphere has been investigated by space-and time-resolved optical...... of the laser ablated plasma plume propagation in a background gas. (C) 2003 Elsevier B.V All rights reserved....

  8. Laser-induced fluorescence for medical diagnostics

    International Nuclear Information System (INIS)

    Andersson Engels, S.

    1989-12-01

    Laser-induced fluorescence as a tool for tissue diagnostics is discussed. Both spectrally and time-resolved fluorescence signals are studied to optimize the demarcation of diseased lesions from normal tissue. The presentation is focused on two fields of application: the identification of malignant tumours and atherosclerotic plaques. Tissue autofluorescence as well as fluorescence from administered drugs have been utilized in diseased tissue diagnosis. The fluorescence criterion for tissue diagnosis is, as far as possible, chosen to be independent of unknown fluorescence parameters, which are not correlated to the type of tissue investigated. Both a dependence on biological parameters, such as light absorption in blood, and instrumental characteristics, such as excitation pulse fluctuations and detection geometry, can be minimized. Several chemical compounds have been studied in animal experiments after intraveneous injection to verify their capacity as malignant tumour marking drugs under laser excitation and fluorescence detection. Another objective of these studies was to improve our understanding of the mechanism and chemistry behind the retention of the various drugs in tissue. The properties of a chemical which maximize its selective retention in tumours are discussed. In order to utilize this diagnostic modality, three different clinically adapted sets of instrumentation have been developed and are presented. Two of the systems are nitrogen-laser-based fluorosensors; one is a point-monitoring system with full spectral resolution and the other one is an imaging system with up to four simultaneously recorded images in different spectral bands. The third system is a low-cost point-monitoring mercury-lamp-based fluoroscence emission as well as reflection characteristics of tissue. (author)

  9. An Experimental Technique for Structural Diagnostic Based on Laser Vibrometry and Neural Networks

    Directory of Open Access Journals (Sweden)

    Paolo Castellini

    2000-01-01

    Full Text Available In recent years damage detection techniques based on vibration data have been largely investigated with promising results for many applications. In particular, several attempts have been made to determine which kind of data should be extracted for damage monitoring.

  10. Laser and plasma diagnostics for the OMEGA Upgrade Laser System (invited) (abstract)

    International Nuclear Information System (INIS)

    Letzring, S.A.

    1995-01-01

    The upgraded OMEGA laser system will be capable of delivering up to 30 kJ of 351-nm laser light with various temporal pulse shapes onto a variety of targets for both ICF and basic plasma physics experiments. ICF experiments will cover a wide parameter space up to near-ignition conditions, and basic interaction and plasma physics experiments will cover previously unattainable parameter spaces. The laser system is the tool with which the experiments are performed; the diagnostics, both of the laser system and the interaction between the laser and the target, form the heart of the experiment. A new suite of diagnostics is now being designed and constructed. Most of these are based on diagnostics previously fielded on the OMEGA laser system very successfully over the last ten years, but there are some new diagnostics, both for the laser and the interaction experiments, which have had to be invented. Laser system diagnostics include high-energy, full-beam calorimetry for all of the 60 beams of the upgrade; a novel, multispectral energy-measuring system for assessing the tuning of the frequency-multiplying crystals; a beam-balance diagnostic that forms the heart of the energy-balance system; and a peak power diagnostic that forms the heart of the power-balance system. Target diagnostics will include the usual time-integrated x-ray imaging systems, both pinhole cameras and x-ray microscopes; x-ray spectrometers, both imaging and spatially integrating; plamsa calorimeters, including x-ray calorimetry; and time-resolved x-ray diagnostics, both nonimaging and imaging in one and two dimensions. Neutron diagnostics will include several measurements of total yield, secondary, and possibly tertiary yield and neutron spectroscopy with several time-of-flight spectrometers. Other measurements will include ''knock-on'' particle measurements and neutron activation of shell materials as a diagnostic of compressed fuel and shell density

  11. Multigigahertz beam diagnostics for laser fusion

    International Nuclear Information System (INIS)

    Smith, R.C.; Hodson, E.K.; Carlson, R.L.

    1981-01-01

    A system to make ultra wideband measurements of fast laser pulses and their induced target interactions at a distance of approximately 38 m from the target location is discussed. The system has demonstrated an overall bandwidth of 3 GHz with projected unfolding to 4 GHz. This system allows high resolution temporal history diagnostics in a remote location providing high EMI and radiation immunity

  12. Investigation of relativistic laser-plasmas using nuclear diagnostics

    International Nuclear Information System (INIS)

    Guenther, Marc M.

    2011-01-01

    The present work explores with the development of a novel nuclear diagnostic method for the investigation of the electron dynamics in relativistic laser-plasma interactions. An additional aim of this work was the determination of the real laser peak intensity via the interaction of an intense laser short-pulse with a solid target. The nuclear diagnostics is based on a photo-neutron disintegration nuclear activation method. The main constituent of the nuclear diagnostic are novel pseudoalloic activation targets as a kind of calorimeter to measure the high-energy bremsstrahlung produced by relativistic electrons. The targets are composed of several stable isotopes with different (γ,xn)-reaction thresholds. The activated nuclides were identified via the characteristic gamma-ray decay spectrum by using high-resolution gamma spectroscopy after the laser irradiation. Via the gamma spectroscopy the (γ,xn)-reaction yields were determined. The high-energy bremsstrahlung spectrum has been deconvolved using a novel analysis method based on a modified Penfold-Leiss method. This facilitates the reconstruction of the spectrum of bremsstrahlung photons without any anticipated fit procedures. Furthermore, the characterization of the corresponding bremsstrahlung electrons in the interaction zone is accessible immediately. The consolidated findings about the properties of the relativistic electrons were used to determine the real peak intensity at the laser-plasma interaction zone. In the context of this work, experiments were performed at three different laser facilities. First Experiments were carried out at the 100 TW laser facility at Laboratoire pour l'Utilisation des Lasers Intense (LULI) in France and supplementary at the Vulcan laser facility at Rutherford Appleton Laboratory (RAL) in United Kingdom. The main part of the activation experiments were performed at the PHELIX laser facility (Petawatt High Energy Laser for heavy Ion EXperiments) at GSI-Helmholtzzentrum fuer

  13. Laser Diagnostics for Spacecraft Propulsion

    Science.gov (United States)

    2015-10-13

    for public release; distribution unlimited.  AFTC/PA Clearance No.  XXXX 3 Motivation • Many satellite propulsion technologies were developed in the...distribution unlimited.  AFTC/PA Clearance No.  XXXX Propellant Catalyst Bed Decomposition Chamber Thrust Chamber 5 Diode Laser Absorption Spectroscopy Beer...Hydrazine Thruster NH3 Iν(L)Iν0 Ramp t I L DISTRIBUTION A:  Approved for public release; distribution unlimited.  AFTC/PA Clearance No.  XXXX 6 Wavelength

  14. Infrared laser scattering system for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, K; Hiraki, N; Kawasaki, S [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1975-05-01

    The possibility of observing the collective scattering of infrared laser light from plasmas is discussed in terms of the laser power requirement, the necessary optical system and the detector performance, and is shown to be feasible with the present day techniques to get the ion temperature by means of a CO/sub 2/ laser on theta pinch plasmas. Based on this estimate, the construction of the TEA CO/sub 2/ laser and the preparations of the optical components have been started and some preliminary results of these are described.

  15. Infrared laser scattering system for plasma diagnostics

    International Nuclear Information System (INIS)

    Muraoka, Katsunori; Hiraki, Naoji; Kawasaki, Shoji

    1975-01-01

    The possibility of observing the collective scattering of infrared laser light from plasmas is discussed in terms of the laser power requirement, the necessary optical system and the detector performance, and is shown to be feasible with the present day techniques to get the ion temperature by means of a CO 2 laser on theta pinch plasmas. Based on this estimate, the construction of the TEA CO 2 laser and the preparations of the optical components have been started and some preliminary results of these are described. (auth.)

  16. Laser cleaning of ITER's diagnostic mirrors

    Science.gov (United States)

    Skinner, C. H.; Gentile, C. A.; Doerner, R.

    2012-10-01

    Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We report on laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150 - 420 nm thick. A 1.06 μm Nd laser system provided 220 ns pulses at 8 kHz with typical power densities of 1-2 J/cm^2. The laser beam was fiber optically coupled to a scanner suitable for tokamak applications. The efficacy of mirror cleaning was assessed with a new technique that combines microscopic imaging and reflectivity measurements [1]. The method is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber. Excellent restoration of reflectivity for the carbon coated Mo mirrors was observed after laser scanning under vacuum conditions. For the beryllium coated mirrors restoration of reflectivity has so far been incomplete and modeling indicates that a shorter duration laser pulse is needed. No damage of the molybdenum mirror substrates was observed.[4pt][1] C.H. Skinner et al., Rev. Sci. Instrum. at press.

  17. Diagnostics of ytterbium/aluminium laser plasmas

    International Nuclear Information System (INIS)

    Bailey, J.; Lee, R.W.; Landen, O.L.; Kilkenny, J.D.; Lewis, C.L.; Busquet, M.

    1986-11-01

    Microdot spectroscopy was used to study the x-ray emission from laser-produced plasmas consisting of 10% ytterbium, 90% aluminium. Spectra were recorded with a space-resolving flat crystal (PET) mini-spectrometer in the 4.0-8.0 A range. The Janus research laser at LLNL irradiated the targets with green (0.53 μm) light in a 1 nsec pulse. The power density was varied between 4x10 13 and 3x10 14 W/cm 2 . The plasma electron density and temperature were determined from the aluminium XI, XII and XIII line emission. By examining correlations between changes in the plasma conditions with changes in the ytterbium spectra, we will determine the potential for using ytterbium line emission as a plasma diagnostic

  18. Infrared laser scattering system for the plasma diagnostics

    International Nuclear Information System (INIS)

    Hiraki, Naoji; Kawasaki, Shoji; Muraoka, Katsunori

    1975-01-01

    As the results of the parametric studies of the double discharge TEA CO 2 laser, the required properties on the laser system for the scattering diagnostics of plasmas are shown to be realized with our CO 2 laser. The direction of the future improvements of the laser performance is also discussed. (auth.)

  19. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  20. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-01-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes

  1. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich; Byrne, Warren; Leemans, Wim

    2011-01-01

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm 2 and 0.4 pC/(ps mm 2 ), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  2. High speed photography diagnostics in laser-plasma interaction experiments

    International Nuclear Information System (INIS)

    Andre, M.L.

    1988-01-01

    The authors report on their effort in the development of techniques involved in laser-plasma experiments. This includes not only laser technology but also diagnostics studies and targets design and fabrication. Among the different kind of diagnostics currently used are high speed streak cameras, fast oscilloscopes and detectors sensitive in the i.r., visible, the u.v. region and the x-rays. In this presentation the authors describe the three high power lasers which are still in operation (P 102, OctAL and PHEBUS) and the main diagnostics used to characterize the plasma

  3. Development of terahertz laser diagnostics for electron density measurements.

    Science.gov (United States)

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2008-10-01

    A two color laser interferometer using terahertz laser sources is under development for high performance operation on the large helical device and for future burning plasma experiments such as ITER. Through investigation of terahertz laser sources, we have achieved high power simultaneous oscillations at 57.2 and 47.6 microm of a CH(3)OD laser pumped by a cw 9R(8) CO(2) laser line. The laser wavelength around 50 microm is the optimum value for future fusion devices from the consideration of the beam refraction effect and signal-to-noise ratio for an expected phase shift due to plasma. In this article, recent progress of the terahertz laser diagnostics, especially in mechanical vibration compensation by using a two color laser operation and terahertz laser beam transmission through a dielectric waveguide, will be presented.

  4. Diagnostics developments and applications for laser fusion experiments

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1977-01-01

    Some diagnostics techniques applied to current laser fusion target experiments are reviewed. Specifically, holographic interferometry of target plasmas, coded aperture imaging of thermonuclear alpha-particles and neutron energy spectrum measurements are discussed

  5. Final Report - DOE Center for Laser Imaging and Cancer Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Alfano, Robert R.; Koutcher, Jason A.

    2002-10-31

    This Final Report summarizes the significant progress made by the researchers, students and staff of the Center for Laser Imaging and Cancer Diagnostics (CLICD) from January 1998 through May 2002. During this period, the Center supported several projects. Most projects were proposed initially, some were added subsequently as their relevance and importance to the DOE mission became evident. DOE support has been leveraged to obtain continuing funding for some projects. Leveraged funds come from various sources, including NIH, Army, NSF and the Air Force. The goal of the Center was to develop laser-based instruments for use in the detection and diagnosis of major diseases, with an emphasis on detection and diagnosis of various cancers. Each of the supported projects is a collaborative effort between physicists and laser scientists and the City College of New York and noted physicians, surgeons, pathologists, and biologists located at medical centers in the Metropolitan area. The participating institutions were: City College of New York Institute for Ultrafast Lasers and Spectroscopy, Hackensack University Medical Center, Lawrence Livermore National Laboratory, Memorial Sloan Kettering Cancer Center, and New York Eye and Ear Institute. Each of the projects funded by the Center is grouped into one of four research categories: a) Disease Detection, b) Non-Disease Applications, c) New Diagnostic Tools, and, d) Education, Training, Outreach and Dissemination. The progress achieved by the multidisciplinary teams was reported in 51 publications and 32 presentations at major national conferences. Also, one U.S. patent was obtained and six U.S. patent applications have been filed for innovations resulting from the projects sponsored by the Center.

  6. Arduino based laser control

    OpenAIRE

    Bernal Muñoz, Ferran

    2015-01-01

    ARDUINO is a vey usefull platform for prototypes. In this project ARDUINO will be used for controling a Semiconductor Tuneable Laser. [ANGLÈS] Diode laser for communications control based on an Arduino board. Temperature control implementation. Software and hardware protection for the laser implementation. [CASTELLÀ] Control de un láser de comunicaciones ópticas desde el ordenador utilizando una placa Arduino. Implementación de un control de temperatura y protección software y hardware ...

  7. Diagnostics for studies of novel laser ion acceleration mechanisms

    OpenAIRE

    Senje, Lovisa; Yeung, Mark; Aurand, Bastian; Kuschel, Stephan; Rödel, Christian; Wagner, Florian; Li, Kun; Dromey, Brendan; Bagnoud, Vincent; Neumayer, Paul; Roth, Markus; Wahlström, Claes-Göran; Zepf, Matthew; Kuehl, Thomas; Jung, Daniel

    2014-01-01

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflecte...

  8. Diagnostics for studies of novel laser ion acceleration mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Senje, Lovisa; Aurand, Bastian; Wahlström, Claes-Göran [Department of Physics, Lund University, P. O. Box 118, S-221 00 Lund (Sweden); Yeung, Mark; Kuschel, Stephan; Rödel, Christian [Helmholtz-Institut Jena, D-07743 Jena (Germany); Wagner, Florian; Roth, Markus [Technische Universität Darmstadt, D-64289 Darmstadt (Germany); Li, Kun; Neumayer, Paul [ExtreMe Matter Institut, D-64291 Darmstadt (Germany); Dromey, Brendan; Jung, Daniel [Department of Physics and Astronomy, Queen' s University, Belfast BT7 1NN (United Kingdom); Bagnoud, Vincent [Helmholtz-Institut Jena, D-07743 Jena (Germany); GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Zepf, Matthew [Helmholtz-Institut Jena, D-07743 Jena (Germany); Department of Physics and Astronomy, Queen' s University, Belfast BT7 1NN (United Kingdom); Kuehl, Thomas [ExtreMe Matter Institut, D-64291 Darmstadt (Germany); GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Universität Mainz, D-55099 Mainz (Germany)

    2014-11-15

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.

  9. Diagnostics for studies of novel laser ion acceleration mechanisms

    International Nuclear Information System (INIS)

    Senje, Lovisa; Aurand, Bastian; Wahlström, Claes-Göran; Yeung, Mark; Kuschel, Stephan; Rödel, Christian; Wagner, Florian; Roth, Markus; Li, Kun; Neumayer, Paul; Dromey, Brendan; Jung, Daniel; Bagnoud, Vincent; Zepf, Matthew; Kuehl, Thomas

    2014-01-01

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution

  10. Lasers as a tool for plasma diagnostics

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1981-01-01

    Lasers can be used as non-perturbative probes to measure many plasma parameters. Plasma refractivity is primarily a function of electron density, and interferometric measurements of phase changes with either pulsed or CW lasers can determine this parameter with spatial or temporal resolution over several orders of magnitude sensitivity by using laser wavelengths from the near uv to the far infrared. Laser scattering from free electrons yields the most fundamental electron temperature measurements in the plasma parameter range where individual scattering events are uncorrelated in phase and ion temperature or plasma wave and turbulence structure in the opposite limit. Laser scattering from bound electrons can be many orders of magnitude larger if the laser is matched to appropriate resonance frequencies and can be used in specialized circumstances for measuring low-ionized impurity or dominant species neutral concentrations and velocities

  11. High-Intensity Laser Diagnostics for OMEGA EP

    International Nuclear Information System (INIS)

    Bromage, J.; Zuegel, J.D.; Bahk, S.-W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Junquist, R.; Stoeckl, C.

    2006-01-01

    OMEGA EP is a new high-energy petawatt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from <1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy petawatt laser at full energy

  12. High-intensity laser diagnostics for OMEGA EP

    Energy Technology Data Exchange (ETDEWEB)

    Bromage, J.; Zuegel, J.D.; Bahk, S.W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Jungquist, R.; Stoeckl, C. [Rochester Univ., Lab. for Laser Energetics, NY (United States)

    2006-06-15

    OMEGA EP (Extended Performance) is a new high-energy peta-watt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from < 1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy peta-watt laser at full energy. (authors)

  13. High-intensity laser diagnostics for OMEGA EP

    International Nuclear Information System (INIS)

    Bromage, J.; Zuegel, J.D.; Bahk, S.W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Jungquist, R.; Stoeckl, C.

    2006-01-01

    OMEGA EP (Extended Performance) is a new high-energy peta-watt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from < 1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy peta-watt laser at full energy. (authors)

  14. Applications of quantum cascade lasers in plasma diagnostics: a review

    International Nuclear Information System (INIS)

    Röpcke, J; Lang, N; Davies, P B; Rousseau, A; Welzel, S

    2012-01-01

    Over the past few years mid-infrared absorption spectroscopy based on quantum cascade lasers operating over the region from 3 to 12 µm and called quantum cascade laser absorption spectroscopy or QCLAS has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, nitrogen oxides and organo-silicon compounds has led to further applications of QCLAS because most of these compounds and their decomposition products are infrared active. QCLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species at time resolutions below a microsecond, which is of particular importance for the investigation of reaction kinetics and dynamics. Information about gas temperature and population densities can also be derived from QCLAS measurements. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of QCLAS techniques to industrial requirements including the development of new diagnostic equipment. The recent availability of external cavity (EC) QCLs offers a further new option for multi-component detection. The aim of this paper is fourfold: (i) to briefly review spectroscopic issues arising from applying pulsed QCLs, (ii) to report on recent achievements in our understanding of molecular phenomena in plasmas and at surfaces, (iii) to describe the current status of industrial process monitoring in the mid-infrared and (iv) to discuss the potential of advanced instrumentation based on EC-QCLs for plasma diagnostics. (topical review)

  15. Optically pumped FIR lasers and their application in plasma diagnostics

    International Nuclear Information System (INIS)

    Bakos, J.S.

    1986-06-01

    The pysics and the construction of the far infrared lasers (FIRL) and of the infrared lasers pumping them are reviewed. The details of the construction, resonating and pumping systems, spectral and power characteristics of the FIRLs are discussed. Recently more than 1000 laser lines are known and used in the 27-80 mm wavelength range, but in many cases the laser kinetics are not fully understood, and some instability phenomena cannot be prevented. New nonlinear processes were found: two-photon pumping, hyper Raman laser tuning and relaxation phenomena. A broad application field, the plasma diagnostics by far infrared lasers is described. Scattering of infrared laser radiation can give new interesting information on the not understood effect of the anomalous transport in the high temperature plasma. (D.Gy.)

  16. Diagnostics for advanced laser acceleration experiments

    International Nuclear Information System (INIS)

    Misuri, Alessio

    2002-01-01

    The first proposal for plasma based accelerators was suggested by 1979 by Tajima and Dawson. Since then there has been a tremendous progress both theoretically and experimentally. The theoretical progress is particularly due to the growing interest in the subject and to the development of more accurate numerical codes for the plasma simulations (especially particle-in-cell codes). The experimental progress follows from the development of multi-terawatt laser systems based on the chirped-pulse amplification technique. These efforts have produced results in several experiments world-wide, with the detection of accelerated electrons of tens of MeV. The peculiarity of these advanced accelerators is their ability to sustain extremely large acceleration gradients. In the conventional radio frequency linear accelerators (RF linacs) the acceleration gradients are limited roughly to 100 MV/m; this is partially due to breakdown which occurs on the walls of the structure. The electrical breakdown is originated by the emission of the electrons from the walls of the cavity. The electrons cause an avalanche breakdown when they reach other metal parts of the RF linacs structure

  17. Diagnostics for advanced laser acceleration experiments

    Energy Technology Data Exchange (ETDEWEB)

    Misuri, Alessio [Univ. of Pisa (Italy)

    2002-01-01

    The first proposal for plasma based accelerators was suggested by 1979 by Tajima and Dawson. Since then there has been a tremendous progress both theoretically and experimentally. The theoretical progress is particularly due to the growing interest in the subject and to the development of more accurate numerical codes for the plasma simulations (especially particle-in-cell codes). The experimental progress follows from the development of multi-terawatt laser systems based on the chirped-pulse amplification technique. These efforts have produced results in several experiments world-wide, with the detection of accelerated electrons of tens of MeV. The peculiarity of these advanced accelerators is their ability to sustain extremely large acceleration gradients. In the conventional radio frequency linear accelerators (RF linacs) the acceleration gradients are limited roughly to 100 MV/m; this is partially due to breakdown which occurs on the walls of the structure. The electrical breakdown is originated by the emission of the electrons from the walls of the cavity. The electrons cause an avalanche breakdown when they reach other metal parts of the RF linacs structure.

  18. Three-dimensional laser pulse intensity diagnostic for photoinjectors

    Directory of Open Access Journals (Sweden)

    Heng Li

    2011-11-01

    Full Text Available Minimizing the electron-beam emittance of photoinjectors is an important task for maximizing the brightness of the next-generation x-ray facilities, such as free-electron lasers and energy recovery linacs. Optimally shaped laser pulses can significantly reduce emittance. A reliable diagnostic for the laser pulse intensity is required for this purpose. We demonstrate measurement of three-dimensional spatiotemporal intensity profiles, with spatial resolution of 20  μm and temporal resolution of 130 fs. The capability is illustrated by measurements of stacked soliton pulses and pulses from a dissipative-soliton laser.

  19. Fibre-optic laser-assisted infrared tumour diagnostics (FLAIR)

    Science.gov (United States)

    Bindig, U.; Müller, G.

    2005-08-01

    Laser based fibre-optic surgery procedures are commonly used in minimal invasive surgery. Despite the development of precise and efficient laser systems there are also innovative attempts in the field of bio-medical diagnostics. As a direct result of the tissue's optical properties most applications are focused on the visible wavelength range of the spectrum. The extension of the spectrum up to the mid-infrared (IR) region will offer a broad range of possibilities for novel strategies with a view to non-invasive diagnostics in medicine. We describe a method to detect differences between diseased and normal tissues, which involve Fourier transform IR microspectroscopy and fibre-optics methods. Regions of interest on 10 µm thin tissue sections were mapped using an IR microscope in transmission mode. After IR-mapping, the samples were analysed using standard pathological techniques. Quadratic discriminant and correlation analyses were applied to the IR maps obtained allowing differentiation between cancerous and normal tissue. The use of optical fibres, transparent in the mid-IR, allowed measurements to be made in the attenuated total reflectance (ATR)-mode at a remote location. The IR sensor is in contact with the sample that shows characteristic absorption lines. The total transmission of the fibre and the sample will decrease at these lines. This method can be used to determine the absorption of a sample in a non-destructive manner. In this paper we report on our efforts to develop an IR fibre-optic sensor for tissue identification as well as to differentiate between malignant and healthy tissue in vivo. We also describe the technical design of the laboratory set-up and the results of developments made. Silver halide fibres and a special sensor tip were used for the ATR measurements on tissue specimens. The results indicate that fibre-optic IR spectrometry will be a useful tool for bio-diagnostics.

  20. Fibre-optic laser-assisted infrared tumour diagnostics (FLAIR)

    International Nuclear Information System (INIS)

    Bindig, U; Mueller, G

    2005-01-01

    Laser based fibre-optic surgery procedures are commonly used in minimal invasive surgery. Despite the development of precise and efficient laser systems there are also innovative attempts in the field of bio-medical diagnostics. As a direct result of the tissue's optical properties most applications are focused on the visible wavelength range of the spectrum. The extension of the spectrum up to the mid-infrared (IR) region will offer a broad range of possibilities for novel strategies with a view to non-invasive diagnostics in medicine. We describe a method to detect differences between diseased and normal tissues, which involve Fourier transform IR microspectroscopy and fibre-optics methods. Regions of interest on 10 μm thin tissue sections were mapped using an IR microscope in transmission mode. After IR-mapping, the samples were analysed using standard pathological techniques. Quadratic discriminant and correlation analyses were applied to the IR maps obtained allowing differentiation between cancerous and normal tissue. The use of optical fibres, transparent in the mid-IR, allowed measurements to be made in the attenuated total reflectance (ATR)-mode at a remote location. The IR sensor is in contact with the sample that shows characteristic absorption lines. The total transmission of the fibre and the sample will decrease at these lines. This method can be used to determine the absorption of a sample in a non-destructive manner. In this paper we report on our efforts to develop an IR fibre-optic sensor for tissue identification as well as to differentiate between malignant and healthy tissue in vivo. We also describe the technical design of the laboratory set-up and the results of developments made. Silver halide fibres and a special sensor tip were used for the ATR measurements on tissue specimens. The results indicate that fibre-optic IR spectrometry will be a useful tool for bio-diagnostics

  1. Laser beam diagnostics for metalworking applications

    International Nuclear Information System (INIS)

    Ramos, T.J.; Lingenfelter, A.C.

    1984-01-01

    The Materials Fabrication Division of Lawrence Livermore National Laboratory (LLNL) has three pulsed Nd-YAG lasers dedicated to metalworking. The units are used in a job shop primarily for welding. They also have a number of applications requiring cutting and drilling capability. Each of these metalworking operations requires somewhat different laser beam characteristics. As most investigators have found, the mode of the laser beam and the mode stability are the key variables which must be controlled if optimum results are to be achieved. The authors use several techniques to observe and measure these variables, i.e. Charge Couple Device (CCD) Camera, Thermal Image Plate and thermal-sensitive paper

  2. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  3. Laser-aided diagnostics of plasmas and gases

    CERN Document Server

    Muraoka, K

    2000-01-01

    Updated and expanded from the original Japanese edition, Laser-Aided Diagnostics of Gases and Plasmas takes a unique approach in treating laser-aided diagnostics. The book unifies the subject by joining applications instead of describing each application as a totally separate system. In taking this approach, it highlights the relative strengths of each method and shows how they can complement each other in the study of gases and plasmas.The first part of the book presents a general introduction to the laser-aided study of gases and plasmas, including the various principles and hardware needed for each method, while the second part describes the applications of each general system in detail.Beneficial to a wide spectrum of academic and industrial researchers, this book provides a solid examination of the various options and methods available when involved in the analysis and diagnostics of gases and plasmas.

  4. X-ray diagnostics for laser matter interaction experiments

    International Nuclear Information System (INIS)

    Troussel, Ph.

    2000-01-01

    Advances in the field of laser-driven inertially confined thermonuclear fusion research since the early 1990's are reviewed. It covers the experimental techniques used to study the interaction of laser radiation with matter and high density plasma. A high performance instrumentation (diagnostics) for observation of X radiation (from a few eV to a few keV) will be required to understand the physical processes involved in the interaction. This paper is a three-part: first part, describes diagnostics metrology realized around different X-ray sources (synchrotron, laser plasma...); a second part, synthesizes theoretical and experimental X-ray optics studies and show the interest for direct applications as X-ray spectroscopy and X-ray imaging around laser-produced plasma; a third part, is a review of high resolution X-ray imaging, performances of these optical system were summarized. (author)

  5. Electron beam charge diagnostics for laser plasma accelerators

    Directory of Open Access Journals (Sweden)

    K. Nakamura

    2011-06-01

    Full Text Available A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs. First, a scintillating screen (Lanex was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160  pC/mm^{2} and 0.4  pC/(ps  mm^{2}, respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  6. Beam diagnostics for Laser-induced proton generation at KAERI

    International Nuclear Information System (INIS)

    Kim, Dong Heun; Park, Seong Hee; Jeong, Young Uk; Lee, Ki Tae; Chan, Young Ho; Lee, Byung Cheol; Yoo, Byeong Duk

    2005-01-01

    With an advent of femto-second lasers, a laseraccelerated ion generation has been world-widely studied for medical and nuclear applications. It is known that protons with the energy from several tens MeV to a few hundreds MeV require for a cancer therapy and nuclear reaction. Even though, up to present, the maximum energy of laser-accelerated proton is about 60 MeV, it is expected that the energy of protons generated can be obtained at least up to 150 MeV. According to theoretical and experimental works, it turns out the energy distribution and the flux of ions strongly depends on the intensity of a fs laser at a target. However, physics on laser-plasma interaction is still not clear. The precise measurements of parameters of a fs laser and ions are important to figure out the physics and develop the theoretical interpretation. Typically, beam diagnostic system includes measurements and/or monitoring of the temporal and spatial profiles of lasers at the target as well as the energy spectrum and density profile of protons, which are critical for the analysis of mechanism and the characterization of protons generated. We fabricated and installed the target chamber for laser-accelerated proton generation and are now integrating beam diagnostic system. For laser diagnostics, beam monitoring and alignment system has been installed. For a charged particle, CR-39 detectors, Thomson parabola spectrometer, and Si charged particle detectors are installed for density profile and energy spectrum. In this paper, we discuss the laser beam monitoring and alignment system. We also estimates expected spectrum of protons from Thomson parabola spectrometer, depending on the parameters of protons

  7. Towards novel compact laser sources for non-invasive diagnostics and treatment

    Science.gov (United States)

    Rafailov, Edik U.; Litvinova, Karina S.; Sokolovski, Sergei G.

    2015-08-01

    An important field of application of lasers is biomedical optics. Here, they offer great utility for diagnosis, therapy and surgery. For the development of novel methods of laser-based biomedical diagnostics careful study of light propagation in biological tissues is necessary to enhance our understanding of the optical measurements undertaken, increase research and development capacity and the diagnostic reliability of optical technologies. Ultimately, fulfilling these requirements will increase uptake in clinical applications of laser based diagnostics and therapeutics. To address these challenges informative biomarkers relevant to the biological and physiological function or disease state of the organism must be selected. These indicators are the results of the analysis of tissues and cells, such as blood. For non-invasive diagnostics peripheral blood, cells and tissue can potentially provide comprehensive information on the condition of the human organism. A detailed study of the light scattering and absorption characteristics can quickly detect physiological and morphological changes in the cells due to thermal, chemical, antibiotic treatments, etc [1-5]. The selection of a laser source to study the structure of biological particles also benefits from the fact that gross pathological changes are not induced and diagnostics make effective use of the monochromatic directional coherence properties of laser radiation.

  8. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  9. Double-grating polychromator for laser-aided plasma diagnostics

    International Nuclear Information System (INIS)

    Mukhin, E.E.; Razdobarin, G.T.; Semenov, V.V.; Shilnikov, A.N.; Sukhanov, V.L.; Tolstjakov, S.Yu.; Kochergin, M.M.; Mihailovskij, Yu.K.; Bakh, L.I.

    2004-01-01

    A wide bandpass double-grating polychromator with high rejection and high transmission has been designed and manufactured for laser-aided plasma diagnostics. The special mount utilizes subtractive dispersion in the second stage of the double polychromator such that the larger dispersion of the second stage is reduced by that of the first stage. This affects the intensity of the stray light background at the laser wavelength. The background at the edge of the laser line was measured at 10 -5 of the light incident on the input slit. At the short end of the 200 nm bandpass, the stray light relative intensity approached 10 -7

  10. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  11. Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Matlis, N.H.; Bakeman, M.; Geddes, C.G.R.; Gonsalves, T.; Lin, C.; Nakamura, K.; Osterhoff, J.; Plateau, G.R.; Schroeder, C.B.; Shiraishi, S.; Sokollik, T.; van Tilborg, J.; Toth, Cs.; Leemans, W.P.

    2010-01-01

    We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

  12. Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Matlis, N. H.; Bakeman, M.; Geddes, C. G. R.; Gonsalves, T.; Lin, C.; Nakamura, K.; Osterhoff, J.; Plateau, G. R.; Schroeder, C. B.; Shiraishi, S.; Sokollik, T.; van Tilborg, J.; Toth, Cs.; Leemans, W. P.

    2010-06-01

    We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

  13. The motional stark effect with laser-induced fluorescence diagnostic

    Science.gov (United States)

    Foley, E. L.; Levinton, F. M.

    2010-05-01

    The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.

  14. EAST-AIA deployment under vacuum: Calibration of laser diagnostic system using computer vision

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Cheng, Yong; Feng, Hansheng; Wu, Zhenwei; Li, Yingying; Sun, Yongjun; Zheng, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Bruno, Vincent; Eric, Villedieu [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2016-11-15

    Highlights: • The first deployment of the EAST articulated inspection arm robot under vacuum is presented. • A computer vision based approach to measure the laser spot displacement is proposed. • An experiment on the real EAST tokamak is performed to validate the proposed measure approach, and the results shows that the measurement accuracy satisfies the requirement. - Abstract: For the operation of EAST tokamak, it is crucial to ensure that all the diagnostic systems are in the good condition in order to reflect the plasma status properly. However, most of the diagnostic systems are mounted inside the tokamak vacuum vessel, which makes them extremely difficult to maintain under high vacuum condition during the tokamak operation. Thanks to a system called EAST articulated inspection arm robot (EAST-AIA), the examination of these in-vessel diagnostic systems can be performed by an embedded camera carried by the robot. In this paper, a computer vision algorithm has been developed to calibrate a laser diagnostic system with the help of a monocular camera at the robot end. In order to estimate the displacement of the laser diagnostic system with respect to the vacuum vessel, several visual markers were attached to the inner wall. This experiment was conducted both on the EAST vacuum vessel mock-up and the real EAST tokamak under vacuum condition. As a result, the accuracy of the displacement measurement was within 3 mm under the current camera resolution, which satisfied the laser diagnostic system calibration.

  15. Investigation of relativistic laser-plasmas using nuclear diagnostics; Untersuchung relativistischer Laserplasmen mittels nukleardiagnostischer Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc M.

    2011-01-19

    The present work explores with the development of a novel nuclear diagnostic method for the investigation of the electron dynamics in relativistic laser-plasma interactions. An additional aim of this work was the determination of the real laser peak intensity via the interaction of an intense laser short-pulse with a solid target. The nuclear diagnostics is based on a photo-neutron disintegration nuclear activation method. The main constituent of the nuclear diagnostic are novel pseudoalloic activation targets as a kind of calorimeter to measure the high-energy bremsstrahlung produced by relativistic electrons. The targets are composed of several stable isotopes with different ({gamma},xn)-reaction thresholds. The activated nuclides were identified via the characteristic gamma-ray decay spectrum by using high-resolution gamma spectroscopy after the laser irradiation. Via the gamma spectroscopy the ({gamma},xn)-reaction yields were determined. The high-energy bremsstrahlung spectrum has been deconvolved using a novel analysis method based on a modified Penfold-Leiss method. This facilitates the reconstruction of the spectrum of bremsstrahlung photons without any anticipated fit procedures. Furthermore, the characterization of the corresponding bremsstrahlung electrons in the interaction zone is accessible immediately. The consolidated findings about the properties of the relativistic electrons were used to determine the real peak intensity at the laser-plasma interaction zone. In the context of this work, experiments were performed at three different laser facilities. First Experiments were carried out at the 100 TW laser facility at Laboratoire pour l'Utilisation des Lasers Intense (LULI) in France and supplementary at the Vulcan laser facility at Rutherford Appleton Laboratory (RAL) in United Kingdom. The main part of the activation experiments were performed at the PHELIX laser facility (Petawatt High Energy Laser for heavy Ion EXperiments) at GSI

  16. The development of the intelligent diagnostic expert system for high power dye-laser MOPA system

    International Nuclear Information System (INIS)

    Liu Lianhua; Yang Wenxi; Zhang Xiaowei; Dan Yongjun

    2014-01-01

    A intelligent diagnostic expert system was required to simulate the expert thinking process of solving problem in experiment and to real-time judge the running state of the experiment system. The intelligent diagnostic expert system for dye-laser MOPA system was build with the modular design of separated knowledge base and inference engine, the RETE algorithm rules match, the asynchronous operation, and multithreading technology. The experiment result indicated that the system could real-time analysis and diagnose the running state of dye-laser MOPA system with advantages of high diagnosis efficiency, good instantaneity and strong expansibility. (authors)

  17. Laser fusion experiments, facilities and diagnostics at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Ahlstrom, H.G.

    1980-02-01

    The progress of the LLL Laser Fusion Program to achieve high gain thermonuclear micro-explosions is discussed. Many experiments have been successfully performed and diagnosed using the large complex, 10-beam, 30 TW Shiva laser system. A 400 kJ design of the 20-beam Nova laser has been completed. The construction of the first phase of this facility has begun. New diagnostic instruments are described which provide one with new and improved resolution, information on laser absorption and scattering, thermal energy flow, suprathermal electrons and their effects, and final fuel conditions. Measurements were made on the absorption and Brillouin scattering for target irradiations at both 1.064 μm and 532 nm. These measurements confirm the expected increased absorption and reduced scattering at the shorter wavelength. Implosion experiments have been performed which have produced final fuel densities over the range of 10x to 100x liquid DT density

  18. Influence of laser parameters on the relativistic short electron bunches dynamics in linear accelerators based on RF-guns and development of associated diagnostics

    International Nuclear Information System (INIS)

    Vinatier, T.

    2015-01-01

    My thesis investigates dynamics and diagnostics related to short electron bunches, namely whose rms duration is not directly measurable by an electronic method locating the border at a few tens of picoseconds. The short nature of the bunch and the necessity of a high peak current for the applications imply strong space-charge forces leading to a degradation of beam properties, as its transverse emittance and duration. The main difficulty is to characterize, model and take into account these effects. The chapter 2 consists in the measurements of several properties of these bunches: charge, transverse emittance, energy and duration. The originality of my work is that I use simple methods, both on the theoretical (analytical at maximum) and technological (using only common elements of electron accelerators) point of view. I have developed a method of charge measurement from the measurement of the light intensity emitted by a scintillating screen following the interaction with an electron beam. I have also developed a method to measure the bunch mean energy with a steering magnet and a scintillating screen, via the displacement of the bunch centroid as a function of the field of the steering magnet. I have also adapted multi-parametric methods to measure the transverse emittance and duration of electron bunches. These indirect methods allow the determination of these properties from the measurement of other more accessible properties: the transverse dimensions for the transverse emittance and the energy spread for the duration. The chapter 3 consists in the comparison of the properties of short electron beams, single or longitudinally modulated, generated by 3 different methods: Injection of a short or longitudinally modulated laser pulse in an RF-gun; Magnetic compression in a chicane; and RF-compression in an accelerating structure (Velocity Bunching). I have shown that, at equal conditions of charge, the generation of short bunches thanks to a short laser pulse

  19. Optical diagnostics of lead and PbGa2S4 layered crystal laser plasmas

    International Nuclear Information System (INIS)

    Shuaibov, A.K.; Dashchenko, A.I.; Shevera, I.V.

    2001-01-01

    Paper presents the results of the optic diagnostics of plasma of laser flames formed from lead surface and PbGa 2 S 4 laminar crystal using a neodymium laser. It is shown that the most intensive lines in the lead laser plasma are as follows: 405.7, 368.3, 364.0 nm PbI and 220.4 nm PbII while for the laminar crystal base plasma - the combination of the most intensive lines of PbI and GaI emission. One determined the narrow point of recombination fluxes for the ion and the atomic components of laser plasma of lead and of PbGa 2 S 4 crystal. One conducted comparison study of emission dynamics of PbI and GaI lines in laser plasma of the respective metals and of PbGa 2 S 4 crystal [ru

  20. [Value of new laser technologies in occupational diseases diagnostics].

    Science.gov (United States)

    Liubchenko, P N; Dmitruk, L I; Rogatkin, D A; Karpov, V N; Shumskaia, O V

    2007-01-01

    The article deals with results of microhemodynamics assessment through new methods of noninvasive laser diagnostics--doppler flowmetry and spectrophotometry ("Spectrotest" device)--in vibration disease patients to verify origin of angiodystonic and angiospastic syndromes. The methods enable to define type of microcirculatory disorder, to evaluate quantity of revealed changes, to assess blood content of superficial tissues in fingers, blood oxygenation. Spastic type of microcirculation is indicative to include ACF inhibitors into treatment complex.

  1. Laser diagnostics on magnetically insulated flashover pulsed ion diodes

    International Nuclear Information System (INIS)

    Horioka, K.; Tazima, N.; Fukui, T.; Kasuya, K.

    1989-01-01

    Our recent experimental results on the characteristics of a flashover-type applied-B magnetically insulated pulsed ion diode are described. The main issues are to investigate the cause of impurity of the extracted beam and to examine the effect of neutral particles on the diode characteristics. In the experiment, our main efforts were placed on laser diagnostics of the diode gap behavior. (author)

  2. Proposed development of novel diagnostics for intense, ultrafast laser-plasma experiments at JAEA-KPSI

    International Nuclear Information System (INIS)

    Bolton, Paul R.; Tatchyn, Roman; Fukuda, Yuji; Kando, Masaki; Daito, Izuru; Ma, Jinglong; Chen, Liming; Pirozhkov, Alexander; Tajima, Toshiki

    2007-01-01

    Development of new diagnostics is critical for future laser-plasma accelerators, laser-driven light sources and for x-ray FELs. Recent laser wakefield electron acceleration developments and novel beam-based light source schemes (such as free electron lasers) obviate the need for next generation ultrafast diagnostics, capable of temporal resolution of a few femtoseconds (and in some cases attoseconds) for laser pulses (high order harmonics), x-ray pulses and electron bunches. Single shot detection capability in noninvasive and parasitic modes is also important. Alterations of laser pulse spectra and the associated dynamics can be informative diagnostics. The portion of a high intensity laser pulse that is transmitted through a self-induced underdense plasma (such as in laser wakefield acceleration LWFA schemes) carries the effects of plasma processes it has experienced. A distinction between the self-modulated laser wakefield (SMLWF) acceleration regime and the forced laser wakefield (FLWF) acceleration regime is in the spectral signature of the transmitted ir laser pulse. The former regime generates sidebands from stimulated Raman forward scattering (SRS-F) and the latter exhibits general spectral broadening that evidences ir laser pulse compression. Transmitted spectral effects can diagnose these acceleration regimes. Existing noninvasive electro-optic (EO) schemes for detection of ultrashort electron bunches are limited by material properties to temporal resolution at the 50-100 femtosecond level. While timing jitter at conventional accelerators is of this order (or greater), single bunch longitudinal profile measurements can require improvement of at least an order of magnitude. A new FO technique is described here which monitors enhancement and associated dynamics of spectral components in a probe pulse. Three correlation schemes for detecting ultrashort x-ray pulses are described. Two-photon absorption in tailored ion targets is proposed for scanning auto

  3. Non-invasive biomedical research and diagnostics enabled by innovative compact lasers

    Science.gov (United States)

    Litvinova, Karina S.; Rafailov, Ilya E.; Dunaev, Andrey V.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2017-11-01

    For over half a century, laser technology has undergone a technological revolution. These technologies, particularly semiconductor lasers, are employed in a myriad of fields. Optical medical diagnostics, one of the emerging areas of laser application, are on the forefront of application around the world. Optical methods of non- or minimally invasive bio-tissue investigation offer significant advantages over alternative methods, including rapid real-time measurement, non-invasiveness and high resolution (guaranteeing the safety of a patient). These advantages demonstrate the growing success of such techniques. In this review, we will outline the recent status of laser technology applied in the biomedical field, focusing on the various available approaches, particularly utilising compact semiconductor lasers. We will further consider the advancement and integration of several complimentary biophotonic techniques into single multimodal devices, the potential impact of such devices and their future applications. Based on our own studies, we will also cover the simultaneous collection of physiological data with the aid a multifunctional diagnostics system, concentrating on the optimisation of the new technology towards a clinical application. Such data is invaluable for developing algorithms capable of delivering consistent, reliable and meaningful diagnostic information, which can ultimately be employed for the early diagnosis of disease conditions in individuals from around the world.

  4. Applying Quantum Cascade Laser Spectroscopy in Plasma Diagnostics

    Directory of Open Access Journals (Sweden)

    Jürgen Röpcke

    2016-07-01

    Full Text Available The considerably higher power and wider frequency coverage available from quantum cascade lasers (QCLs in comparison to lead salt diode lasers has led to substantial advances when QCLs are used in pure and applied infrared spectroscopy. Furthermore, they can be used in both pulsed and continuous wave (cw operation, opening up new possibilities in quantitative time resolved applications in plasmas both in the laboratory and in industry as shown in this article. However, in order to determine absolute concentrations accurately using pulsed QCLs, careful attention has to be paid to features like power saturation phenomena. Hence, we begin with a discussion of the non-linear effects which must be considered when using short or long pulse mode operation. More recently, cw QCLs have been introduced which have the advantage of higher power, better spectral resolution and lower fluctuations in light intensity compared to pulsed devices. They have proved particularly useful in sensing applications in plasmas when very low concentrations have to be monitored. Finally, the use of cw external cavity QCLs (EC-QCLs for multi species detection is described, using a diagnostics study of a methane/nitrogen plasma as an example. The wide frequency coverage of this type of QCL laser, which is significantly broader than from a distributed feedback QCL (DFB-QCL, is a substantial advantage for multi species detection. Therefore, cw EC-QCLs are state of the art devices and have enormous potential for future plasma diagnostic studies.

  5. Laser-based additive manufacturing of metals

    CSIR Research Space (South Africa)

    Kumar, S

    2010-11-01

    Full Text Available For making metallic products through Additive Manufacturing (AM) processes, laser-based systems play very significant roles. Laser-based processes such as Selective Laser Melting (SLM) and Laser Engineered Net Shaping (LENS) are dominating processes...

  6. Laser-powered lunar base

    International Nuclear Information System (INIS)

    Costen, R.; Humes, D.H.; Walker, G.H.; Williams, M.D.; Deyoung, R.J.

    1989-01-01

    The objective was to compare a nuclear reactor-driven Sterling engine lunar base power source to a laser-to-electric converter with orbiting laser power station, each providing 1 MW of electricity to the lunar base. The comparison was made on the basis of total mass required in low-Earth-orbit for each system. This total mass includes transportation mass required to place systems in low-lunar orbit or on the lunar surface. The nuclear reactor with Sterling engines is considered the reference mission for lunar base power and is described first. The details of the laser-to-electric converter and mass are discussed. The next two solar-driven high-power laser concepts, the diode array laser or the iodine laser system, are discussed with associated masses in low-lunar-orbit. Finally, the payoff for laser-power beaming is summarized

  7. Relativistic electron kinetic effects on laser diagnostics in burning plasmas

    Science.gov (United States)

    Mirnov, V. V.; Den Hartog, D. J.

    2018-02-01

    Toroidal interferometry/polarimetry (TIP), poloidal polarimetry (PoPola), and Thomson scattering systems (TS) are major optical diagnostics being designed and developed for ITER. Each of them relies upon a sophisticated quantitative understanding of the electron response to laser light propagating through a burning plasma. Review of the theoretical results for two different applications is presented: interferometry/polarimetry (I/P) and polarization of Thomson scattered light, unified by the importance of relativistic (quadratic in vTe/c) electron kinetic effects. For I/P applications, rigorous analytical results are obtained perturbatively by expansion in powers of the small parameter τ = Te/me c2, where Te is electron temperature and me is electron rest mass. Experimental validation of the analytical models has been made by analyzing data of more than 1200 pulses collected from high-Te JET discharges. Based on this validation the relativistic analytical expressions are included in the error analysis and design projects of the ITER TIP and PoPola systems. The polarization properties of incoherent Thomson scattered light are being examined as a method of Te measurement relevant to ITER operational regimes. The theory is based on Stokes vector transformation and Mueller matrices formalism. The general approach is subdivided into frequency-integrated and frequency-resolved cases. For each of them, the exact analytical relativistic solutions are presented in the form of Mueller matrix elements averaged over the relativistic Maxwellian distribution function. New results related to the detailed verification of the frequency-resolved solutions are reported. The precise analytic expressions provide output much more rapidly than relativistic kinetic numerical codes allowing for direct real-time feedback control of ITER device operation.

  8. The possibilities of laser scattering diagnostics in plasmas

    International Nuclear Information System (INIS)

    Doebele, H.F.

    1974-01-01

    The laser has opened many new possibilities for plasma diagnostics. Intensive monochromatic light sources with higher precision and better time resolution have helped to improve such well-known techniques as interferometry and Schlieren method. At the same time, the range of applicability was extended into the infrared range. Due to the wave length dependence of the plasma diffraction index, the effects increase approximately lambda in interferometry and approximately lambda 2 in the Schlieren methods. The laser also helped to develop entirely new methods such as utilization of the Faraday effect in the electrons of a plasma in a magnetic field which allows the calculation of the product nsub(e) x B from the rotation of the polarization plane of monochromatic light with linear polarization. Here, too, the effect increases approximately lambda 2 , and measurements have been carried out up to FIR (HCN,337 μ). The best diagnostic possibilities are offered by the Thomson scattering diagnostics. Electron and ion temperatures, electron densities, drift velocities, magnetic fields, wave propagation and dissipation can be measured by this method. (orig./AK) [de

  9. Computer-based diagnostic decisionmaking.

    Science.gov (United States)

    Miller, R A

    1987-12-01

    The three decisionmaking aids described by the authors attack the generic problem of "see no evil, hear no evil, speak no evil"--improving the detection, diagnosis, and therapy of psychiatric disorders in the primary care setting. The three systems represent interventions at different steps in the process of providing appropriate care to psychiatric patients. The DSPW system of Robins and Marcus offers the potential of increasing the recognition of psychiatric disease in the physician's office. Politser's IDS program is representative of the sort of sophisticated microcomputer-based decisionmaking support tools that will become available to physicians in the not-too-distant future. Erdman's study of the impact of explanation capabilities on the acceptability of therapy recommending systems points out the need for careful scientific evaluations of features added to diagnostic and therapeutic systems.

  10. Proteome-based bacterial identification using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS): A revolutionary shift in clinical diagnostic microbiology.

    Science.gov (United States)

    Nomura, Fumio

    2015-06-01

    Rapid and accurate identification of microorganisms, a prerequisite for appropriate patient care and infection control, is a critical function of any clinical microbiology laboratory. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a quick and reliable method for identification of microorganisms, including bacteria, yeast, molds, and mycobacteria. Indeed, there has been a revolutionary shift in clinical diagnostic microbiology. In the present review, the state of the art and advantages of MALDI-TOF MS-based bacterial identification are described. The potential of this innovative technology for use in strain typing and detection of antibiotic resistance is also discussed. This article is part of a Special Issue entitled: Medical Proteomics. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Laser beam alignment and profilometry using diagnostic fluorescent safety mirrors

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    There are a wide range of laser beam delivery systems in use for various purposes; including industrial and medical applications. Virtually all such beam delivery systems for practical purposes employ optical systems comprised of mirrors and lenses to shape, focus and guide the laser beam down to the material being processed. The goal of the laser beam delivery is to set the optimum parameters and to "fold" the beam path to reduce the mechanical length of the optical system, thereby allowing a physically compact system. In many cases, even a compact system can incorporate upwards of six mirrors and a comparable number of lenses all needing alignment so they are collinear. One of the major requirements for use of such systems in industry is a method of safe alignment. The alignment process requires that the aligner determine where the beam strikes each element. The aligner should also preferably be able to determine the shape or pattern of the laser beam at that point and its relative power. These alignments are further compounded in that the laser beams generated are not visible to the unaided human eye. Such beams are also often of relatively high power levels, and are thereby a significant hazard to the eyes of the aligner. Obvious an invisible beam makes it nearly impossible to align laser system without some form of optical assistance. The predominant method of visually aligning the laser beam delivery is the use of thermal paper, paper cards or fluorescing card material. The use of paper products which have limited power handling capability or coated plastics can produce significant debris and contaminants within the beam line that ultimately damage the optics. The use of the cards can also create significant laser light scatter jeopardizing the safety of the person aligning the system. This paper covers a new safety mirror design for use with at various UV and Near IR wavelengths (193 nm to 1064 nm) within laser beam delivery systems and how its use can

  12. Modeling pulsed excitation for gas-phase laser diagnostics

    International Nuclear Information System (INIS)

    Settersten, Thomas B.; Linne, Mark A.

    2002-01-01

    Excitation dynamics for pulsed optical excitation are described with the density-matrix equations and the rate equations for a two-level system. A critical comparison of the two descriptions is made with complete and consistent formalisms that are amenable to the modeling of applied laser-diagnostic techniques. General solutions, resulting from numerical integration of the differential equations describing the excitation process, are compared for collisional conditions that range from the completely coherent limit to the steady-state limit, for which the two formalisms are identical. This analysis demonstrates the failure of the rate equations to correctly describe the transient details of the excitation process outside the steady-state limit. However, reasonable estimates of the resultant population are obtained for nonsaturating (linear) excitation. This comparison provides the laser diagnostician with the means to evaluate the appropriate model for excitation through a simple picture of the breakdown of the rate-equation validity

  13. Diagnostics for an XUV/soft x-ray laser

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Ceglio, N.; Medecki, H.

    1984-01-01

    We have begun investigating the production of an XUV/soft x-ray laser, using our high-powered glass lasers as drivers. A major diagnostic for lasing is the measure of the absolute power produced in the lasing line. I have developed a spectrograph to time-resolved lasing lines in the energy range from 50 eV to greater than 200 eV. the spectrograph combines a transmission grating and x-ray streak camera to produce a flat field instrument. A cylindrical mirror is used in front of the grating to image the source and act as a collecting optic. The efficiency of the components is calibrated so that absolute intensities can be measured. I will compare the performance of this instrument with reflection grating systems. I will also discuss planned improvements to the system which should increase total throughput, image quality, and resolving power

  14. A dual far-infrared laser diagnostic of magnetized plasmas

    International Nuclear Information System (INIS)

    Darrow, D.S.; Park, H.K.

    1988-02-01

    A dual far-infrared laser has been constructed and its properties have been exploited to probe tokamak-like discharges in the CDX toroidal device. Thermal variation of the difference frequency between the two far-infrared cavities is slow, though the cavities lack thermal stabilization, simply because their assembly on the same chassis exposes them to virtually identical temperature changes. The optical arrangement beyond the laser permits conversion within minutes between interferometry and density fluctuation observation, and within an hour between different operating wavelengths. Line-average densities of 2 /times/ 10 13 cm -3 and coherent fluctuations in the neighborhood of 20 kHz have been measured with this diagnostic. 15 refs., 5 figs., 2 tabs

  15. Full aperture backscatter diagnostic for the NIF laser facility (abstract)

    International Nuclear Information System (INIS)

    Sewall, Noel; Lewis, Izzy; Kirkwood, Robert; Moody, John; Celeste, John

    2001-01-01

    The current schemes for achieving ignition on the National Ignition Facility require efficient coupling of energy from 192 laser beams to the deuterium--tritium fuel capsule. Each laser beam must propagate through a long scalelength plasma region before being converted to x rays (indirect drive) or being absorbed on the capsule (direct drive). Laser-plasma instabilities such as stimulated Brillouin and stimulated Raman scattering (SBS and SRS) will scatter a fraction of the incident laser energy out of the target leading to an overall reduction in the coupling efficiency. It is important to measure the character of this scattered light in order to understand it and to develop methods for reducing it to acceptable levels. We are designing a system called the full aperature backscatter diagnostic with the capability to measure the time-dependent amplitude and spectral content of the light which is backscattered through the incident beam focusing optic. The backscattered light will be collected over about 85% of the full beam aperture and separated into the SBS wavelength band (348--354 nm) and the SRS wavelength band (400--700 nm). Spectrometers coupled to streak cameras will provide time-resolved spectra for both scattered light components. The scattered light amplitude will be measured with fast and slow diodes. The entire system will be routinely calibrated. Analysis of the data will provide important information for reducing scattered power, achieving power balance, and finally achieving ignition

  16. Construction of a nitrogen laser for plasma diagnostics

    International Nuclear Information System (INIS)

    Ishiekwene, G.C.

    1994-07-01

    The challenge faced in finding new sources of energy to bridge the gap between the availability and demand of energy is difficult to be overemphasized. Nuclear fusion seems to provide a potentially limitless source of energy which offers a bright prospect for solving this problem. Although an elaborate programme in fusion may be beyond the economic reach of most third world countries, some modest experiments are necessary to provide an indigenous expertise capable of enhancing international fusion studies. In order to initiate experimental research sufficient for plasma studies at an affordable cost to developing countries, this paper illustrates the construction of a simple, low cost, high power nitrogen laser and investigates some of its performance characteristics. Also, the laser is utilized as a source of illumination in the techniques of shadowgraphy. A series of shadowgrams depicting the temporal development of the plasma discharge is presented. The constructed laser is found to be cost-effective and useful in small-scale researches in laser-plasma diagnostics. (author). 6 refs, 5 figs

  17. Nuclear diagnostics of high intensity laser plasma interactions

    International Nuclear Information System (INIS)

    Krushelnick, K.; Santala, M.I.K.; Beg, F.N.; Clark, E.L.; Dangor, A.E.; Tatarakis, M.; Watts, I.; Wei, M.S.; Zepf, M.; Ledingham, K.W.D.; McCanny, T.; Spencer, I.; Clarke, R.J.; Norreys, P.A.

    2002-01-01

    Nuclear activation has been observed in materials exposed to energetic protons and heavy ions generated from high intensity laser-solid interactions (at focused intensities up to 5x10 19 W/cm 2 ). The energy spectrum of the protons is determined through the use of these nuclear activation techniques and is found to be consistent with other ion diagnostics. Heavy ion fusion reactions and large neutron fluxes from the (p, n) reactions were also observed. The reduction of proton emission and increase in heavy ion energy using heated targets was also observed

  18. Laser diagnostics of the energy spectrum of Rydberg states of the lithium-7 atom

    Energy Technology Data Exchange (ETDEWEB)

    Zelener, B. B., E-mail: bobozel@mail.ru; Saakyan, S. A.; Sautenkov, V. A.; Manykin, E. A.; Zelener, B. V.; Fortov, V. E. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    The spectra of excited lithium-7 atoms prepared in a magneto-optical trap are studied using a UV laser. The laser diagnostics of the energy of Rydberg atoms is developed based on measurements of the change in resonance fluorescence intensity of ultracold atoms as the exciting UV radiation frequency passes through the Rydberg transition frequency. The energies of various nS configurations are obtained in a broad range of the principal quantum number n from 38 to 165. The values of the quantum defect and ionization energy obtained in experiments and predicted theoretically are discussed.

  19. Applications of laser diagnostics to thermal power plants and engines

    International Nuclear Information System (INIS)

    Deguchi, Y.; Kamimoto, T.; Wang, Z.Z.; Yan, J.J.; Liu, J.P.; Watanabe, H.; Kurose, R.

    2014-01-01

    The demands for lowering the burdens on the environment will continue to grow steadily. It is important to monitor controlling factors in order to improve the operation of industrial thermal systems. In engines, exhaust gas temperature and concentration distributions are important factors in nitrogen oxides (NO x ), total hydrocarbon (THC) and particulate matter (PM) emissions. Coal and fly ash contents are parameters which can be used for the control of coal-fired thermal power plants. Monitoring of heavy metals such as Hg is also important for pollution control. In this study, the improved laser measurement techniques using computed tomography-tunable diode laser absorption spectroscopy (CT-TDLAS), low pressure laser-induced breakdown spectroscopy (LIBS), and laser breakdown time-of-flight mass spectrometry (LB-TOFMS) have been developed and applied to measure 2D temperature and species concentrations in engine exhausts, coal and fly ash contents, and trace species measurement. The 2D temperature and NH 3 concentration distributions in engine exhausts were successfully measured using CT-TDLAS. The elemental contents of size-segregated particles were measured and the signal stability increased using LIBS with the temperature correction method. The detection limit of trace species measurement was enhanced using low pressure LIBS and LB-TOFMS. The detection limit of Hg can be enhanced to 3.5 ppb when employing N 2 as the buffer gas using low pressure LIBS. Hg detection limit was about 0.82 ppb using 35 ps LB-TOFMS. Compared to conventional measurement methods laser diagnostics has high sensitivity, high response and non-contact features for actual industrial systems. With these engineering developments, transient phenomena such as start-ups in thermal systems can be evaluated to improve the efficiency of these thermal processes. - Highlights: • Applicability of newly developed laser diagnostics was demonstrated for the improvement of thermal power plants and

  20. Picosecond high power laser systems and picosecond diagnostic technique in laser produced plasma

    International Nuclear Information System (INIS)

    Kuroda, Hiroto; Masuko, H.; Maekawa, Shigeru; Suzuki, Yoshiji; Sugiyama, Masaru.

    1979-01-01

    Highly repetitive, high power YAG and Glass laser systems have been developed and been successfully used for the studies of laser-plasma interactions. Various picosecond diagnostic techniques have been developed for such purposes in the regions from optical to X-ray frequency. Recently highly sensitive X-ray (1 - 10 KeV) streak camera for highly repetitive operations have been developed. Preliminary experiment shows the achievement of 28ps temporal resolution (100μm slit) and good sensitivity with detectable minimum number of 10E3-1KeV photons/shot/slit area. (author)

  1. Development of two color laser diagnostics for the ITER poloidal polarimeter.

    Science.gov (United States)

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2010-10-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  2. Development of two color laser diagnostics for the ITER poloidal polarimeter

    International Nuclear Information System (INIS)

    Kawahata, K.; Akiyama, T.; Tanaka, K.; Nakayama, K.; Okajima, S.

    2010-01-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH 3 OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  3. Physics of laser fusion. Volume II. Diagnostics of experiments on laser fusion targets at LLNL

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstrom, H.G.

    1982-01-01

    These notes present the experimental basis and status for laser fusion as developed at LLNL. There are two other volumes in this series: Vol. I, by C.E. Max, presents the theoretical laser-plasma interaction physics; Vol. III, by J.F. Holzrichter et al., presents the theory and design of high-power pulsed lasers. A fourth volume will present the theoretical implosion physics. The notes consist of six sections. The first, an introductory section, provides some of the history of inertial fusion and a simple explanation of the concepts involved. The second section presents an extensive discussion of diagnostic instrumentation used in the LLNL Laser Fusion Program. The third section is a presentation of laser facilities and capabilities at LLNL. The purpose here is to define capability, not to derive how it was obtained. The fourth and fifth sections present the experimental data on laser-plasma interaction and implosion physics. The last chapter is a short projection of the future.

  4. Time-resolved diagnostics of excimer laser-generated ablation plasmas used for pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Geohegan, D.B.

    1994-09-01

    Characteristics of laser plasmas used for pulsed laser deposition (PLD) of thin films are examined with four in situ diagnostic techniques: Optical emission spectroscopy, optical absorption spectroscopy, ion probe studies, and gated ICCD (intensified charge-coupled-device array) fast photography. These four techniques are complementary and permit simultaneous views of the transport of ions, excited states, ground state neutrals and ions, and hot particulates following KrF laser ablation of YBCO, BN, graphite and Si in vacuum and background gases. The implementation and advantages of the four techniques are first described in order to introduce the key features of laser plasmas for pulsed laser deposition. Aspects of the interaction of the ablation plume with background gases (i.e., thermalization, attenuation, shock formation) and the collision of the plasma plume with the substrate heater are then summarized. The techniques of fast ICCD photography and gated photon counting are then applied to investigate the temperature, velocity, and spatial distribution of hot particles generated during KrF ablation of YBCO, BN, Si and graphite. Finally, key features of fast imaging of the laser ablation of graphite into high pressure rare gases are presented in order to elucidate internal reflected shocks within the plume, redeposition of material on a surface, and formation of hot nanoparticles within the plume.

  5. Time-resolved diagnostics of excimer laser-generated ablation plasmas used for pulsed laser deposition

    International Nuclear Information System (INIS)

    Geohegan, D.B.

    1994-01-01

    Characteristics of laser plasmas used for pulsed laser deposition (PLD) of thin films are examined with four in situ diagnostic techniques: Optical emission spectroscopy, optical absorption spectroscopy, ion probe studies, and gated ICCD (intensified charge-coupled-device array) fast photography. These four techniques are complementary and permit simultaneous views of the transport of ions, excited states, ground state neutrals and ions, and hot particulates following KrF laser ablation of YBCO, BN, graphite and Si in vacuum and background gases. The implementation and advantages of the four techniques are first described in order to introduce the key features of laser plasmas for pulsed laser deposition. Aspects of the interaction of the ablation plume with background gases (i.e., thermalization, attenuation, shock formation) and the collision of the plasma plume with the substrate heater are then summarized. The techniques of fast ICCD photography and gated photon counting are then applied to investigate the temperature, velocity, and spatial distribution of hot particles generated during KrF ablation of YBCO, BN, Si and graphite. Finally, key features of fast imaging of the laser ablation of graphite into high pressure rare gases are presented in order to elucidate internal reflected shocks within the plume, redeposition of material on a surface, and formation of hot nanoparticles within the plume

  6. Physics of laser fusion. Volume II. Diagnostics of experiments on laser fusion targets at LLNL

    International Nuclear Information System (INIS)

    Ahlstrom, H.G.

    1982-01-01

    These notes present the experimental basis and status for laser fusion as developed at LLNL. There are two other volumes in this series: Vol. I, by C.E. Max, presents the theoretical laser-plasma interaction physics; Vol. III, by J.F. Holzrichter et al., presents the theory and design of high-power pulsed lasers. A fourth volume will present the theoretical implosion physics. The notes consist of six sections. The first, an introductory section, provides some of the history of inertial fusion and a simple explanation of the concepts involved. The second section presents an extensive discussion of diagnostic instrumentation used in the LLNL Laser Fusion Program. The third section is a presentation of laser facilities and capabilities at LLNL. The purpose here is to define capability, not to derive how it was obtained. The fourth and fifth sections present the experimental data on laser-plasma interaction and implosion physics. The last chapter is a short projection of the future

  7. Image-converter diagnostics of laser and laser plasma in pico-femtosecond region

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1979-01-01

    In the present communication we would like to outline some new trends in development of pico-femtosecond image-converter diagnostics for laser and laser plasma research on the basis of the recent works done in P.N.Lebedev Physical Institute. The discussion of the following subjects will be included: new generation of picosecond image-converter tubes (ICT), pulsed control circuitry, late prototype of picosecond image-converter cameras (ICC), test installation consisting of Nd: glass and YAG lasers for production the ultra-short pulses and sinusoidally modulated radiation, methods and techniques for image tube and camera dynamic measurements in IR, visible and X-ray spectral regions. Also discussed are the image processing technique for pictures taken with picosecond ICC in order to correct the geometrical distortions, enhance pictures quality and evaluate parameters of the input signals through their recorded images. (author)

  8. Laser diagnostics in combustion. Elastic scattering and picosecond laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Ossler, Frederik

    1999-05-01

    Elastic scattering and the Lorenz-Mie (LM) theory in particular is used for the characterization of sub-micron- and micron-sized droplets of organic fuels in sprays and aerosols. Calculations on the Lorenz-Mie theory show that backward-sideward scattered visible radiation can be used for unambiguous detection of ensembles of homogeneous droplets of organic substances with diameters around 1 micrometer (size parameter between 2 and 6). A backward feature in the polarization ratio appears with a value considerably higher than one, on the opposite to the case of the rainbow observed for larger droplets. A comparison between measurements and LM calculations showed that a large amount of droplets in aerosols and well-atomized sprays were smaller than one micrometer in diameter. The LM theory was also used to characterize different size groups in a burning spray. A 3 - D technique based on a picosecond laser and a streak camera was demonstrated for measurements of fast and turbulent biphase flows. The entire 3 - D information was obtained within a time-span of less than 15 nanoseconds. A 2 - D technique for lifetime measurements based on a picosecond laser and a streak camera has been demonstrated on static objects. An analysis indicates that the technique may be applied to measurements of lifetimes around or below one picosecond employing femtosecond lasers and femtosecond streak-cameras. The technique may in principle be used to study dynamic systems when two detectors are used. Fluorescence lifetime measurements on hydrogen and oxygen atoms in flames at atmospheric pressure demonstrate the need of lasers with suiting spectral properties such as jitter and linewidth and the need of detectors with high sensitivity in the near IR in the case of oxygen atoms. The fluorescence lifetimes of gas phase acetone and 3-pentanone at 266 nm excitation wavelength have been measured for mixtures with nitrogen and air at temperatures between 323 and 723 K and pressures between 0

  9. Survey Talk--New Laser and Optical Radiation Diagnostics

    International Nuclear Information System (INIS)

    Leemans, W.P.

    1998-01-01

    New techniques am reported for electron beam monitoring, that rely either on the analysis of the properties of wiggler radiation (from static magnetic fields as well as from laser ''undulators'', also referred to as Thomson scattering) or on the non-linear mixing of laser radiation with electron beam radiation. The different techniques reviewed are capable of providing information on femtosecond time scales and micron or even sub-micron spatial scales. The laser undulator is also proposed as a useful tool for non- destructive measurement of high power electron beams. An example is given of measuring electron beam energy and energy spread through spectral filtering of spontaneous wiggler radiation [1]. A novel technique based on fluctuational characteristics of radiation is described, for single shot, nondestructive measurement of the electron beam bunch length [2,3]. Thomson scattering based beam monitoring techniques are discussed which, through analysis of the radiated beam properties, allow non-destructive detailed measurement of transverse and longitudinal distributions of relativistic electron beams [4]. Two new techniques are discussed which rely on non-linear optical mixing of laser radiation with electron bunch emission: differential optical gating (DOG) [5] and electron bunch length measurement in a storage ring based on sum-frequency generation [6

  10. UV laser ionization and electron beam diagnostics for plasma lenses

    International Nuclear Information System (INIS)

    Govil, R.; Volfbeyn, P.; Leemans, W.

    1995-04-01

    A comprehensive study of focusing of relativistic electron beams with overdense and underdense plasma lenses requires careful control of plasma density and scale lengths. Plasma lens experiments are planned at the Beam Test Facility of the LBL Center for Beam Physics, using the 50 MeV electron beam delivered by the linac injector from the Advanced Light Source. Here we present results from an interferometric study of plasmas produced in tri-propylamine vapor with a frequency quadrupled Nd:YAG laser at 266 nm. To study temporal dynamics of plasma lenses we have developed an electron beam diagnostic using optical transition radiation to time resolve beam size and divergence. Electron beam ionization of the plasma has also been investigated

  11. Laser-Induced Fluorescence diagnostic of barium ion plasmas in the Paul Trap Simulator Experiment

    International Nuclear Information System (INIS)

    Chung, Moses; Gilson, Erik P.; Davidson, Ronald C.; Efthimion, Philip C.; Majeski, Richard; Startsev, Edward A.

    2005-01-01

    The Paul Trap Simulator Experiment (PTSX) is a cylindrical Paul trap whose purpose is to simulate the nonlinear dynamics of intense charged particle beam propagation in alternating-gradient magnetic transport systems. To investigate the ion plasma microstate in PTSX, including the ion density profile and the ion velocity distribution function, a laser-induced fluorescence diagnostic system is being developed as a nondestructive diagnostic. Instead of cesium, which has been used in the initial phase of the PTSX experiment, barium has been selected as the preferred ion for the laser-induced fluorescence diagnostic. A feasibility study of the laser-induced fluorescence diagnostic using barium ions is presented with the characterization of a tunable dye laser. The installation of the barium ion source and the development of the laser-induced fluorescence diagnostic system are also discussed

  12. UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry in the diagnostics of alopecia

    Science.gov (United States)

    Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.

    2016-04-01

    Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.

  13. Laser Induced Fluorescence Diagnostic for the Plasma Couette Experiment

    Science.gov (United States)

    Katz, Noam; Skiff, Fred; Collins, Cami; Weisberg, Dave; Wallace, John; Clark, Mike; Garot, Kristine; Forest, Cary

    2010-11-01

    The Plasma Couette Experiment (PCX) at U. Wisconsin-Madison consists of a rotating high-beta plasma and is well-suited to the study of flow-driven, astrophysically-relevant plasma phenomena. PCX confinement relies on alternating rings of 1kG permanent magnets and the rotation is driven by electrode rings, interspersed between the magnets, which provide an azimuthal ExB. I will discuss the development of a laser-induced fluorescence diagnostic (LIF) to characterize the ion distribution function of argon plasmas in PCX. The LIF system--which will be scanned radially--will be used to calibrate internal Mach probes, as well as to measure the time-resolved velocity profile, ion temperature and density non-perturbatively. These diagnostics will be applied to study the magneto-rotational instability in a plasma, as well as the buoyancy instability thought to be involved in producing the solar magnetic field. This work is supported by NSF and DOE.

  14. Advanced diagnostics for laser plasma interaction studies and some recent experiments

    International Nuclear Information System (INIS)

    Chaurasia, S.; Munda, D.S.; Dhareshwar, L.J.

    2008-10-01

    The complete characterization of Laser plasma interaction studies related to inertial confinement fusion laser and Equation of state (EOS) studies needs many diagnostics to explain the several physical phenomena occurring simultaneously in the laser produced plasma. This involves many on ion emission are important to understand physical phenomena which are responsible for generation of laser plasma as well as its interaction with an intense laser. In this report we describe the development of various x-ray diagnostics which are used in determining temporal, spatial and spectral properties of x-rays radiated from laser produced plasma. Diagnostics which have been used in experiments for investigation of laser-produced plasma as a source of ions are also described. Techniques using an optical streak camera and VISAR which are being used in the Equation of States (EOS) studies of various materials, which are important for material science, astrophysics as well as ICF is described in details. (author)

  15. A review on laser diagnostics on atomization and evaporation of liquid fuel

    Science.gov (United States)

    Zhang, Yuyin; Li, Shiyan; Lin, Baiyang; Liu, Yang; Wu, Jian; Xu, Bin

    2014-08-01

    To evaluate the atomization and evaporation processes of liquid fuel, there are several laser diagnostics available in present. In this paper, the recent progress in laser diagnostics for atomization and evaporation will be introduced, as two categories: atomization and evaporation. The diagnostics for the former includes the primary breakup from liquid jet to ligaments or droplets and the secondary atomization from a bigger droplet to a smaller one, and the latter includes the droplet evaporation and the vapor distributions in a spray.

  16. Data acquisition system for fusion diagnostics on the ARGUS laser

    International Nuclear Information System (INIS)

    Greenwood, J.R.; Campbell, D.E.; Frerking, C.E.

    1976-09-01

    An extensive data acquisition and analysis system has been implemented for experiments on the ARGUS laser. The system is based upon a PDP-11/40 minicomputer and CAMAC interfaces. Highspeed transient digitizers, calorimeter digitizing modules and time integrated data are interfaced through CAMAC over a fiber optic serial highway. The system allows for dynamic definition of the experimental environment by an operator, automatic data acquisition during a shot. Two interactive graphics terminals allow experimenters real-time access to target shot data

  17. Infrared and far-infrared laser development for plasma diagnostics at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Casson, W.H.; Bennett, C.A.; Fletcher, L.K.; Hunter, H.T.; Hutchinson, D.P.; Lee, J.; Ma, C.DH.; Richards, R.K.; Vander Sluis, K.L.

    1987-01-01

    Three IR and FIR based diagnostics will be developed ann installed on the Advanced Toroidal Facility (ATF) at ORNL. An interferometer operating at 119 mu m will measure plasma density along 14 vertical chords across the plasma cross-section. A small-angle Thomson scattering experiment using a 10.6-mu m pulsed laser will determine the feasibility of measuring alpha particle distribution in a burning plasma. Plans are being developed for installing an FIR-based scattering experiment on ATF to measure density fluctuations. 4 refs., 4 figs

  18. Laser induced desorption as hydrogen retention diagnostic method

    Energy Technology Data Exchange (ETDEWEB)

    Zlobinski, Miroslaw

    2016-07-15

    Laser Induced Desorption Spectroscopy (LIDS) is a diagnostic method to measure the hydrogen content in the surface of a material exposed to a hydrogen isotope (H,D,T) plasma. It is developed mainly to monitor hydrogen retention in the walls of magnetic fusion devices that have to limit the amount of their fuel tritium mainly due to safety reasons. The development of fusion increasingly focusses on plasma-wall interactions for which in situ diagnostics like LIDS are required that work during plasma operation and without tile removal. The method has first been developed for thin amorphous hydrocarbon (a-C:H < 500 nm) layers successfully and is studied in the present work on thick (15 μm) layers, carbon fibre composites (CFCs), bulk tungsten (W), W fuzz and mixed C/W materials. In LID a 3 ms Nd:YAG (1064 nm) laser pulse heats a spot of diameter 3 mm with 500 {sup MW}/{sub m{sup 2}} on W to 1800 K at the surface and thus above 1300 K within ca. 0.2 mm depth. On C materials (graphite, CFC, a-C:H) this temperature guarantees a nearly complete (>95%) desorption already within 1.5 ms pulse duration. The retained hydrogen atoms are desorbed locally, recombine to molecules and migrate promptly to the surface via internal channels like pores and grain boundaries. Whereas, in W the retained hydrogen atoms have to diffuse through the bulk material, which is a relatively slow process also directed into the depth. The desorbed hydrogen fraction can thus be strongly reduced to 18-91% as observed here. This fraction is measured by melting the central part of a previously heated spot ca. 40 μm deep with a diameter 2 mm, 3 ms laser pulse, releasing the remaining hydrogen. W samples exposed to different plasmas in TEXTOR, Pilot-PSI, PSI-2, PADOS and PlaQ show that the desorption fraction of LID mainly decreases due to higher sample temperature during plasma exposure. The heat causes deeper hydrogen diffusion and/or stronger hydrogen trapping due to creation of traps with higher

  19. Laser induced desorption as hydrogen retention diagnostic method

    International Nuclear Information System (INIS)

    Zlobinski, Miroslaw

    2016-01-01

    Laser Induced Desorption Spectroscopy (LIDS) is a diagnostic method to measure the hydrogen content in the surface of a material exposed to a hydrogen isotope (H,D,T) plasma. It is developed mainly to monitor hydrogen retention in the walls of magnetic fusion devices that have to limit the amount of their fuel tritium mainly due to safety reasons. The development of fusion increasingly focusses on plasma-wall interactions for which in situ diagnostics like LIDS are required that work during plasma operation and without tile removal. The method has first been developed for thin amorphous hydrocarbon (a-C:H < 500 nm) layers successfully and is studied in the present work on thick (15 μm) layers, carbon fibre composites (CFCs), bulk tungsten (W), W fuzz and mixed C/W materials. In LID a 3 ms Nd:YAG (1064 nm) laser pulse heats a spot of diameter 3 mm with 500 MW / m 2 on W to 1800 K at the surface and thus above 1300 K within ca. 0.2 mm depth. On C materials (graphite, CFC, a-C:H) this temperature guarantees a nearly complete (>95%) desorption already within 1.5 ms pulse duration. The retained hydrogen atoms are desorbed locally, recombine to molecules and migrate promptly to the surface via internal channels like pores and grain boundaries. Whereas, in W the retained hydrogen atoms have to diffuse through the bulk material, which is a relatively slow process also directed into the depth. The desorbed hydrogen fraction can thus be strongly reduced to 18-91% as observed here. This fraction is measured by melting the central part of a previously heated spot ca. 40 μm deep with a diameter 2 mm, 3 ms laser pulse, releasing the remaining hydrogen. W samples exposed to different plasmas in TEXTOR, Pilot-PSI, PSI-2, PADOS and PlaQ show that the desorption fraction of LID mainly decreases due to higher sample temperature during plasma exposure. The heat causes deeper hydrogen diffusion and/or stronger hydrogen trapping due to creation of traps with higher binding energy

  20. New laser sources for clinical treatment and diagnostics of neonatal jaundice

    Science.gov (United States)

    Hamza, Mostafa; El-Ahl, Mohammad H. S.; Hamza, Ahmad M.

    2001-06-01

    An elevated serum bilirubin concentration in the newborn infant presents a therapeutic as well as a diagnostic problem to the physician. It has long been recognized that high levels of bilirubin cause irreversible brain damage and even death. The authors introduce the use of semiconductor diode lasers and diode-pumped solid-state lasers that can be used for solving such diagnostic and therapeutic problems. These new laser sources can improve the ergonomics of using laser, enhance performance capabilities and reduce the cost of employing laser energy to pump bilirubin out of an infant's body. The choice of laser wavelengths follows the principles of bilirubinometry and phototherapy of neonatal jaundice. The wide spread use of these new laser sources for clinical monitoring and treatment of neonatal hyperbilirubinemia will be made possible as each incremental or quantum jump cost reduction is achieved. Our leading clinical experience as well as the selection rules of laser wavelengths will be presented.

  1. Laser diagnostics of combustion phenomena related to engines/gas turbines. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Alden, Marcus [Lund Inst. of Technology (Sweden). Dept. of Combustion

    2000-05-01

    The following project has been a one year project bridging the time between the NUTEK program in 'Motorrelaterad foerbraenning' and the new STEM program in 'Energisystem i vaegfordon. The activities has included three Ph. D students and the project has been directed towards two main areas. The first area is the development and application of a new laser diagnostic technique based on laser-induced fluorescence from atomic species for measurements of two-dimensional temperatures in combustion systems. The technique has shown to have distinct advantages compared to more commonly used laser techniques and it has been applied both in engines (VOLVO PV) as well as in gas turbines (VOLVO Aero Corp.) A major advantage is the potential, recently investigated, to make measurements in sooty environments. The second area is in the area of development and application of a technique for measurements of two-dimensional soot volume fractions and particle sizes. The technique is called Laser-induced Incandescence, LII, and here a laser beam is heating the particle considerably above the flame temperature and by detecting the increased blackbody radiation, the parameters above can be inferred. During the year most work has been to develop the technique, but distinct applications in burners, engines and model fires are planned.

  2. Knowledge based diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Baldeweg, F.; Fiedler, U.; Weiss, F.P.; Werner, M.

    1987-01-01

    In this paper a special process diagnostic system (PDS) is presented. It must be seen as the result of a long term work on computerized process surveillance and control; it includes a model based system for noise analysis of mechanical vibrations, which has recently been enhanced by using of knowledge based technique (expert systems). The paper discusses the process diagnostic frame concept and emphasize the vibration analysis expert system

  3. Chemical sensors based on quantum cascade lasers

    Science.gov (United States)

    Tittel, Frank K.; Kosterev, Anatoliy A.; Rochat, Michel; Beck, Mattias; Faist, Jerome

    2002-09-01

    There is an increasing need in many chemical sensing applications ranging from industrial process control to environmental science and medical diagnostics for fast, sensitive, and selective gas detection based on laser spectroscopy. The recent availability of novel pulsed and cw quantum cascade distributed feedback (QC-DFB) lasers as mid-infrared spectroscopic sources address this need. A number of spectroscopic techniques have been demonstrated. For example, the authors have employed QC-DFB lasers for the monitoring and quantification of several trace gases and isotopic species in ambient air at ppmv and ppbv levels by means of direct absorption, wavelength modulation, cavity enhanced and cavity ringdown spectroscopy. In this work, pulsed thermoelectrically cooled QC-DFB lasers operating at ~15.6 μm were characterized for spectroscopic gas sensing applications. A new method for wavelength scanning based on the repetition rate modulation was developed. A non-wavelength-selective pyroelectric detector was incorporated in the gas sensor giving an advantage of room-temperature operation and low cost. Absorption lines of CO2 and H2O were observed in ambient air providing information about the concentration of these species.

  4. Diagnostic studies of molecular plasmas using mid-infrared semiconductor lasers

    NARCIS (Netherlands)

    Röpcke, J.; Welzel, S.; Lang, N.; Hempel, F.; Gatilova, L.; Guaitella, O.; Rousseau, A.; Davies, P.B.

    2008-01-01

    Within the last decade mid-infrared absorption spectroscopy between 3 and 20 µm, known as infrared laser absorption spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has

  5. Kinetic and diagnostic studies of molecular plasmas using laser absorption techniques

    NARCIS (Netherlands)

    Welzel, S.; Rousseau, A.; Davies, P.B.; Röpcke, J.

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 µm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has

  6. Nanotechnology based diagnostics for neurological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kurek, Nicholas S; Chandra, Sathees B., E-mail: schandra@roosevelt.edu [Department of Biological, Chemical and Physical Sciences, Roosevelt University, Chicago, IL (United States)

    2012-07-01

    Nanotechnology involves probing and manipulating matter at the molecular level. Nanotechnology based molecular diagnostics have the potential to alleviate the suffering caused by many diseases, including neurological disorders, due to the unique properties of nanomaterials. Most neurological illnesses are multifactorial conditions and many of these are also classified as neurobehavioral disorders. Alzheimer's disease, Parkinson's disease, Huntington disease, cerebral ischemia, epilepsy, schizophrenia and autism spectrum disorders like Rett syndrome are some examples of neurological disorders that could be better treated, diagnosed, prevented and possibly cured using nanotechnology. In order to improve the quality of life for disease afflicted people, a wide range of nanomaterials that include gold and silica nanoparticles, quantum dots and DNA along with countless other forms of nanotechnology have been investigated regarding their usefulness in advancing molecular diagnostics. Other small scaled materials like viruses and proteins also have potential for use as molecular diagnostic tools. Information obtained from nanotechnology based diagnostics can be stored and manipulated using bioinformatics software. More advanced nanotechnology based diagnostic procedures for the acquisition of even greater proteomic and genomic knowledge can then be developed along with better ways to fight various diseases. Nanotechnology also has numerous applications besides those related to biotechnology and medicine. In this article, we will discuss and analyze many novel nanotechnology based diagnostic techniques at our disposal today. (author)

  7. Nanotechnology based diagnostics for neurological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kurek, Nicholas S.; Chandra, Sathees B., E-mail: schandra@roosevelt.edu [Department of Biological, Chemical and Physical Sciences, Roosevelt University, Chicago, IL (United States)

    2012-07-01

    Nanotechnology involves probing and manipulating matter at the molecular level. Nanotechnology based molecular diagnostics have the potential to alleviate the suffering caused by many diseases, including neurological disorders, due to the unique properties of nanomaterials. Most neurological illnesses are multifactorial conditions and many of these are also classified as neurobehavioral disorders. Alzheimer's disease, Parkinson's disease, Huntington disease, cerebral ischemia, epilepsy, schizophrenia and autism spectrum disorders like Rett syndrome are some examples of neurological disorders that could be better treated, diagnosed, prevented and possibly cured using nanotechnology. In order to improve the quality of life for disease afflicted people, a wide range of nanomaterials that include gold and silica nanoparticles, quantum dots and DNA along with countless other forms of nanotechnology have been investigated regarding their usefulness in advancing molecular diagnostics. Other small scaled materials like viruses and proteins also have potential for use as molecular diagnostic tools. Information obtained from nanotechnology based diagnostics can be stored and manipulated using bioinformatics software. More advanced nanotechnology based diagnostic procedures for the acquisition of even greater proteomic and genomic knowledge can then be developed along with better ways to fight various diseases. Nanotechnology also has numerous applications besides those related to biotechnology and medicine. In this article, we will discuss and analyze many novel nanotechnology based diagnostic techniques at our disposal today. (author)

  8. Nanotechnology based diagnostics for neurological disorders

    International Nuclear Information System (INIS)

    Kurek, Nicholas S.; Chandra, Sathees B.

    2012-01-01

    Nanotechnology involves probing and manipulating matter at the molecular level. Nanotechnology based molecular diagnostics have the potential to alleviate the suffering caused by many diseases, including neurological disorders, due to the unique properties of nanomaterials. Most neurological illnesses are multifactorial conditions and many of these are also classified as neurobehavioral disorders. Alzheimer's disease, Parkinson's disease, Huntington disease, cerebral ischemia, epilepsy, schizophrenia and autism spectrum disorders like Rett syndrome are some examples of neurological disorders that could be better treated, diagnosed, prevented and possibly cured using nanotechnology. In order to improve the quality of life for disease afflicted people, a wide range of nanomaterials that include gold and silica nanoparticles, quantum dots and DNA along with countless other forms of nanotechnology have been investigated regarding their usefulness in advancing molecular diagnostics. Other small scaled materials like viruses and proteins also have potential for use as molecular diagnostic tools. Information obtained from nanotechnology based diagnostics can be stored and manipulated using bioinformatics software. More advanced nanotechnology based diagnostic procedures for the acquisition of even greater proteomic and genomic knowledge can then be developed along with better ways to fight various diseases. Nanotechnology also has numerous applications besides those related to biotechnology and medicine. In this article, we will discuss and analyze many novel nanotechnology based diagnostic techniques at our disposal today. (author)

  9. National Ignition Facility, subsystem design requirements beam control and laser diagnostics SSDR 1.7

    International Nuclear Information System (INIS)

    Bliss, E.

    1996-01-01

    This Subsystem Design Requirement document is a development specification that establishes the performance, design, development, and test requirements for the Alignment subsystem (WBS 1.7.1), Beam Diagnostics (WBS 1.7.2), and the Wavefront Control subsystem (WBS 1.7. 3) of the NIF Laser System (WBS 1.3). These three subsystems are collectively referred to as the Beam Control ampersand Laser Diagnostics Subsystem. The NIF is a multi-pass, 192-beam, high-power, neodymium-glass laser that meets requirements set forth in the NIF SDR 002 (Laser System). 3 figs., 3 tabs

  10. Semiconductor laser engineering, reliability and diagnostics a practical approach to high power and single mode devices

    CERN Document Server

    Epperlein, Peter W

    2013-01-01

    This reference book provides a fully integrated novel approach to the development of high-power, single-transverse mode, edge-emitting diode lasers by addressing the complementary topics of device engineering, reliability engineering and device diagnostics in the same book, and thus closes the gap in the current book literature. Diode laser fundamentals are discussed, followed by an elaborate discussion of problem-oriented design guidelines and techniques, and by a systematic treatment of the origins of laser degradation and a thorough exploration of the engineering means to enhance the optical strength of the laser. Stability criteria of critical laser characteristics and key laser robustness factors are discussed along with clear design considerations in the context of reliability engineering approaches and models, and typical programs for reliability tests and laser product qualifications. Novel, advanced diagnostic methods are reviewed to discuss, for the first time in detail in book literature, performa...

  11. Vulnerability analysis of DT fusion diagnostics for laser Megajoule facility. A new tool: Diacad

    International Nuclear Information System (INIS)

    D'hose, C.; Baggio, J.; Musseau, O.

    1999-01-01

    The Megajoule laser (LMJ) project is a major component of the French simulation program to study inertial confinement. This new facility will provide an energy 60 times greater than the largest lasers presently available (Phebus, Nova, Omega). Many diagnostic links will have to be developed in order to acquire complementary knowledge in this domain. A computer based tool has been defined. This paper presents the most recent developments of this new CAD (computer assisted diagnosis) tool. We first describe LMJ context, and then the analysis methodology developed to address the sensitivity to transient radiation of nuclear diagnosis links. This tool takes into account the vulnerability of individual parts and the global structure of the link. (A.C.)

  12. On the possibility of laser diagnostics of anisotropically superheated electrons in magnetic fusion systems

    International Nuclear Information System (INIS)

    Kukushkin, A.B.

    1990-01-01

    The anisotropically superheated electrons (ASE) are known to be generated by a resonance interaction of high-frequency electromagnetic waves with electron plasma. Under definite conditions the ASE energy may essentially exceed (by the order of magnitude or even more) thermal energies of background electron plasma, the ASE distribution in pitch-angle being concentrated around definite directions. This situation is typical for, e.g. electron cyclotron heating of magnetic mirror plasmas (generation of 'sloshing' electrons) and for current drive in tokamaks by means of lower-hybrid or, sometimes, electron cyclotron waves. In this work, an analysis of the possibility of the ASE laser diagnostics is based on the calculations of Thomson scattering of laser radiation by plasma electrons. The model electron velocity distribution functions, which provide qualitative description of the ASE peculiar features, were used in calculations. (author) 4 refs., 1 fig

  13. Development of the Megahertz Planar Laser-induced Fluorescence Diagnostic for Plasma Turbulence Visualization

    International Nuclear Information System (INIS)

    Kuritsyn, Aleksey; Levinton, Fred M.

    2004-01-01

    A megahertz LIF-based diagnostic system for measuring ion density fluctuations in two spatial dimensions is described. Well resolved spatial and temporal 2D images of turbulent structures will be useful in understanding ion turbulence in magnetically confined plasmas which is a key factor in the performance of fusion experimental devices. A sheet beam of a megahertz repetition rate tunable Alexandrite laser is used to excite ion emission from argon plasma. The fluorescence emitted from the plane of the laser beam is detected with a narrow band interference filter and intensified ultra-fast CCD camera providing 2D images of relative ion density fluctuations every microsecond. It is expected that the edge plasma on fusion devices will be accessible to this technique

  14. X-ray calibration facility for plasma diagnostics of the MegaJoule laser

    International Nuclear Information System (INIS)

    Hubert, S.; Prevot, V.

    2013-01-01

    The Laser MegaJoule (LMJ) located at CEA-CESTA will be equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors and cameras. To guarantee LMJ measurements, detectors such as x-ray cameras need to be regularly calibrated. An x-ray laboratory is devoted to this task and performs absolute x-ray calibrations for similar x-ray cameras running on Laser Integration Line (LIL). This paper presents the x-ray calibration bench with its x-ray tube based High Energy x-ray Source (HEXS) and some calibration results. By mean of an ingenious transposition system under vacuum absolute x-ray calibration of x-ray cameras, like streak and stripline ones, can be carried out. Coupled to a new collimation system with micrometric accuracy on aperture sensitivity quantum efficiency measurements can be achieved with reduced uncertainties. (authors)

  15. X-ray diagnostics for laser matter interaction experiments; Diagnostics X pour les experiences d'interaction laser-matiere

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph

    2000-07-01

    Advances in the field of laser-driven inertially confined thermonuclear fusion research since the early 1990's are reviewed. It covers the experimental techniques used to study the interaction of laser radiation with matter and high density plasma. A high performance instrumentation (diagnostics) for observation of X radiation (from a few eV to a few keV) will be required to understand the physical processes involved in the interaction. This paper is a three-part: first part, describes diagnostics metrology realized around different X-ray sources (synchrotron, laser plasma...); a second part, synthesizes theoretical and experimental X-ray optics studies and show the interest for direct applications as X-ray spectroscopy and X-ray imaging around laser-produced plasma; a third part, is a review of high resolution X-ray imaging, performances of these optical system were summarized. (author)

  16. Proceedings of the 13th international symposium on laser-aided plasma diagnostics

    International Nuclear Information System (INIS)

    Kawahata, Kazuo

    2007-09-01

    The 9th international symposium on LASER-AIDED PLASMA DIAGNOSTICS was held from 18th November to 21st September, 2007 at Takayama, Japan. This symposium was organized by the National Institute for Fusion Science, Toki, Japan. The topics of the symposium include laser diagnostics and diagnostics aided by lasers for fusion plasmas, industrial process plasmas, environmental plasmas as well as for other plasma applications and processes related to plasmas. Hardware development related to laser-aided plasma diagnostics is another topic. Over 80 participants attended this international symposium. 1 Akazaki lecture, 10 general talks, 10 topical talks, 12 short oral talks and 45 posters were presented. This issue is the collection of the papers presented at the title symposium. The 41 of the presented papers are indexed individually. (J.P.N.)

  17. The use of laser beams for plasma diagnostics

    International Nuclear Information System (INIS)

    Gex, J.P.; Jolas, A.; Launspach, J.; Schirmann, D.

    1975-01-01

    The optical properties of lasers allow them to be a promising source for plasma diagnosis. The Q-switched lasers provide the opportunity to make observations in a very short time interval down to a few picoseconds. The laser space and time coherence properties allow interferometric measurements of plasma electron densities. Thus in the experiments of laser-matter interactions, the radiation obtained by frequency conversion of the Nd: glass laser emission is used for density measurements (up to 10 20 cm -3 ) in small scale plasmas (approximately equal to 1mm). Owing to the monochromaticity and high intensity of the Q-switched laser radiation, density fluctuations and microscopic instabilities of the plasma can be studied by Thompson scattering measurements. Finally, some statistically isotropic media become birefringent under the action of the strong electrical field of the laser beam radiation. This effect can be used for laser pulse duration measurements in a range not exceeding a few picoseconds [fr

  18. Velocity Plume Profiles for Hall Thrusters Using Laser Diagnostic

    Science.gov (United States)

    2010-06-01

    multiple ionization of the propellant or momentum imparted by neutral xenon. Beam divergence is the angular measurement of the plume as the diameter...A3200 can manually move the stages or operate from a script to automate movement. The program also allows the user to define a local coordinate...primer/ java /lasers/diodelasers/index.html [68] Shore Laser (n.d.) Laser Operation [Online]. http://www.shorelaser.com/Laser_Operation.html [69

  19. Laser patterned carbon–polyethylene mesh electrodes for wound diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Phair, Jolene; Joshi, Mayank; Benson, John; McDonald, Damian; Davis, James, E-mail: james.davis@ulster.ac.uk

    2014-02-14

    Carbon loaded polyethylene films were selected as the base substrate for a mechanically flexible and conductive sensing material for use wound monitoring technologies. The films were processed using laser ablation of the surface to increase the effective surface area of the electrode and then subject to an oxidative electrochemical etch to improve the electron transfer kinetics. The surface morphology of the resulting films was analysed and the electrode performance in relation to monitoring uric acid, a key wound biomarker, was optimized. A prototype smart bandage was designed, based on interfacing the mesh to a portable potentiostat, and the response to urate and potential interferences assessed. - Highlights: • Innovative use of a carbon–polyethylene mesh for wound sensing applications. • Electroanalytical characterisation of a mechanically flexible conductive film. • Design and preliminary characterisation of an integrated smart bandage.

  20. Laser patterned carbon–polyethylene mesh electrodes for wound diagnostics

    International Nuclear Information System (INIS)

    Phair, Jolene; Joshi, Mayank; Benson, John; McDonald, Damian; Davis, James

    2014-01-01

    Carbon loaded polyethylene films were selected as the base substrate for a mechanically flexible and conductive sensing material for use wound monitoring technologies. The films were processed using laser ablation of the surface to increase the effective surface area of the electrode and then subject to an oxidative electrochemical etch to improve the electron transfer kinetics. The surface morphology of the resulting films was analysed and the electrode performance in relation to monitoring uric acid, a key wound biomarker, was optimized. A prototype smart bandage was designed, based on interfacing the mesh to a portable potentiostat, and the response to urate and potential interferences assessed. - Highlights: • Innovative use of a carbon–polyethylene mesh for wound sensing applications. • Electroanalytical characterisation of a mechanically flexible conductive film. • Design and preliminary characterisation of an integrated smart bandage

  1. Laser cleaning of diagnostic mirrors from tokamak-like carbon contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Maffini, A., E-mail: alessandro.maffini@polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Uccello, A. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Dellasega, D. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy); Russo, V. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Perissinotto, S. [Center for Nano Science and Technology @ Polimi, Istituto Italiano di Tecnologia, Milan (Italy); Passoni, M. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy)

    2015-08-15

    This paper presents a laboratory-scale experimental investigation of laser cleaning of diagnostic First Mirrors (FMs). Redeposition of contaminants sputtered from tokamak first wall onto FMs surface could dramatically decrease their reflectivity in an unacceptable way for the functioning of the plasma diagnostic systems. Laser cleaning is a promising solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as FMs and to deposit onto them carbon contaminants with tailored features, resembling those found in tokamaks. The same laser system was also used to perform laser cleaning experiments by means of a sample handling procedure that allows to clean some cm{sup 2} in few minutes. The cleaning effectiveness was evaluated in terms of specular reflectivity recovery and mirror surface integrity. The effect of different laser wavelengths (λ = 1064, 266 nm) on the cleaning process is also addressed.

  2. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    Science.gov (United States)

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  3. Diagnostic tests based on human basophils

    DEFF Research Database (Denmark)

    Kleine-Tebbe, Jörg; Erdmann, Stephan; Knol, Edward F

    2006-01-01

    -maximal responses, termed 'intrinsic sensitivity'. These variables give rise to shifts in the dose-response curves which, in a diagnostic setting where only a single antigen concentration is employed, may produce false-negative data. Thus, in order to meaningfully utilize the current basophil activation tests....... Diagnostic studies using CD63 or CD203c in hymenoptera, food and drug allergy are critically discussed. Basophil-based tests are indicated for allergy testing in selected cases but should only be performed by experienced laboratories....

  4. Laser Spot Detection Based on Reaction Diffusion

    OpenAIRE

    Alejandro Vázquez-Otero; Danila Khikhlukha; J. M. Solano-Altamirano; Raquel Dormido; Natividad Duro

    2016-01-01

    Center-location of a laser spot is a problem of interest when the laser is used for processing and performing measurements. Measurement quality depends on correctly determining the location of the laser spot. Hence, improving and proposing algorithms for the correct location of the spots are fundamental issues in laser-based measurements. In this paper we introduce a Reaction Diffusion (RD) system as the main computational framework for robustly finding laser spot centers. The method presente...

  5. Development of Laser-Induced Fluorescence Diagnostic for the Paul Trap Simulator Experiment

    CERN Document Server

    Chung, Moses; Efthimion, Philip; Gilson, Erik P; Majeski, Richard; Startsev, Edward

    2005-01-01

    The Paul Trap Simulator Experiment (PTSX) is a cylindrical Paul trap whose purpose is to simulate the nonlinear dynamics of intense charged particle beam propagation in alternating-gradient magnetic transport systems. For the in-situ measurement of the transverse ion density profile in the PTSX device, which is essential for the study of beam mismatch and halo particle production, a laser-induced fluorescence diagnostic system is being developed. Instead of cesium, which has been used in the initial phase of the PTSX experiment, barium has been selected as the preferred ion for the laser-induced fluorescence diagnostic. The installation of the barium ion source and the characterization of the tunable dye laser system are discussed. The design of the collection optics with an intensified CCD camera system is also discussed. Finally, initial test results using the laser-induced fluorescence diagnostic will be presented.

  6. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    International Nuclear Information System (INIS)

    Welzel, S; Rousseau, A; Davies, P B; Roepcke, J

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 μm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared

  7. Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

    International Nuclear Information System (INIS)

    Skobelev, I. Yu.; Faenov, A. Ya.; Gasilov, S. V.; Pikuz, T. A.; Pikuz, S. A.; Magunov, A. I.; Boldarev, A. S.; Gasilov, V. A.

    2010-01-01

    X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10 16 -10 18 W/cm 2 with CO 2 clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t ∼ 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of ∼100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

  8. A high repetition rate transverse beam profile diagnostic for laser-plasma proton sources

    Science.gov (United States)

    Dover, Nicholas; Nishiuchi, Mamiko; Sakaki, Hironao; Kando, Masaki; Nishitani, Keita

    2016-10-01

    The recently upgraded J-KAREN-P laser can provide PW peak power and intensities approaching 1022 Wcm-2 at 0.1 Hz. Scaling of sheath acceleration to such high intensities predicts generation of protons to near 100 MeV, but changes in electron heating mechanisms may affect the emitted proton beam properties, such as divergence and pointing. High repetition rate simultaneous measurement of the transverse proton distribution and energy spectrum are therefore key to understanding and optimising the source. Recently plastic scintillators have been used to measure online proton beam transverse profiles, removing the need for time consuming post-processing. We are therefore developing a scintillator based transverse proton beam profile diagnostic for use in ion acceleration experiments using the J-KAREN-P laser. Differential filtering provides a coarse energy spectrum measurement, and time-gating allows differentiation of protons from other radiation. We will discuss the design and implementation of the diagnostic, as well as proof-of-principle results from initial experiments on the J-KAREN-P system demonstrating the measurement of sheath accelerated proton beams up to 20 MeV.

  9. Graphene-based nanoprobes for molecular diagnostics.

    Science.gov (United States)

    Chen, Shixing; Li, Fuwu; Fan, Chunhai; Song, Shiping

    2015-10-07

    In recent years, graphene has received widespread attention owing to its extraordinary electrical, chemical, optical, mechanical and structural properties. Lately, considerable interest has been focused on exploring the potential applications of graphene in life sciences, particularly in disease-related molecular diagnostics. In particular, the coupling of functional molecules with graphene as a nanoprobe offers an excellent platform to realize the detection of biomarkers, such as nucleic acids, proteins and other bioactive molecules, with high performance. This article reviews emerging graphene-based nanoprobes in electrical, optical and other assay methods and their application in various strategies of molecular diagnostics. In particular, this review focuses on the construction of graphene-based nanoprobes and their special advantages for the detection of various bioactive molecules. Properties of graphene-based materials and their functionalization are also comprehensively discussed in view of the development of nanoprobes. Finally, future challenges and perspectives of graphene-based nanoprobes are discussed.

  10. Spectroscopic diagnostics of plasma during laser processing of aluminium

    International Nuclear Information System (INIS)

    Lober, R; Mazumder, J

    2007-01-01

    The role of the plasma in laser-metal interaction is of considerable interest due to its influence in the energy transfer mechanism in industrial laser materials processing. A 10 kW CO 2 laser was used to study its interaction with aluminium under an argon environment. The objective was to determine the absorption and refraction of the laser beam through the plasma during the processing of aluminium. Laser processing of aluminium is becoming an important topic for many industries, including the automobile industry. The spectroscopic relative line to continuum method was used to determine the electron temperature distribution within the plasma by investigating the 4158 A Ar I line emission and the continuum adjacent to it. The plasmas are induced in 1.0 atm pure Ar environment over a translating Al target, using f/7 and 10 kW CO 2 laser. Spectroscopic data indicated that the plasma composition and behaviour were Ar-dominated. Experimental results indicated the plasma core temperature to be 14 000-15 300 K over the incident range of laser powers investigated from 5 to 7 kW. It was found that 7.5-29% of the incident laser power was absorbed by the plasma. Cross-section analysis of the melt pools from the Al samples revealed the absence of any key-hole formation and confirmed that the energy transfer mechanism in the targets was conduction dominated for the reported range of experimental data

  11. Spectroscopic diagnostics of plasma during laser processing of aluminium

    Science.gov (United States)

    Lober, R.; Mazumder, J.

    2007-10-01

    The role of the plasma in laser-metal interaction is of considerable interest due to its influence in the energy transfer mechanism in industrial laser materials processing. A 10 kW CO2 laser was used to study its interaction with aluminium under an argon environment. The objective was to determine the absorption and refraction of the laser beam through the plasma during the processing of aluminium. Laser processing of aluminium is becoming an important topic for many industries, including the automobile industry. The spectroscopic relative line to continuum method was used to determine the electron temperature distribution within the plasma by investigating the 4158 Å Ar I line emission and the continuum adjacent to it. The plasmas are induced in 1.0 atm pure Ar environment over a translating Al target, using f/7 and 10 kW CO2 laser. Spectroscopic data indicated that the plasma composition and behaviour were Ar-dominated. Experimental results indicated the plasma core temperature to be 14 000-15 300 K over the incident range of laser powers investigated from 5 to 7 kW. It was found that 7.5-29% of the incident laser power was absorbed by the plasma. Cross-section analysis of the melt pools from the Al samples revealed the absence of any key-hole formation and confirmed that the energy transfer mechanism in the targets was conduction dominated for the reported range of experimental data.

  12. X-ray diagnostics in the laser-initiated fusion program

    International Nuclear Information System (INIS)

    Godwin, R.P.

    1975-08-01

    The high-density and high-temperature plasma conditions required for successful laser-initiated fusion make x-ray diagnostics a valuable tool in this exciting field. Measurements of the hard x-ray continuum emitted from laser targets provide insight into the complex laser-plasma coupling physics and the consequent energy transport through the bremsstrahlung signature of energetic electrons. X-ray techniques are important in the selection and assay of microballoon targets for current compression experiments. X-ray imaging experiments and diffraction spectroscopy of highly stripped atoms can provide information upon the symmetry, density and temperature of laser targets. Extremely high temporal and spatial resolution may be required for definitive diagnostic information on compressed targets. While laser-produced plasmas are interesting as possible intense x-ray sources and as a possible means of achieving x-ray lasing, those topics are outside the scope of this review. (auth)

  13. Features of laser spectroscopy and diagnostics of plasma ions in high magnetic fields

    International Nuclear Information System (INIS)

    Semerok, A F; Fomichev, S V

    2003-01-01

    Laser induced fluorescence and laser absorption spectroscopies of plasma ions in high magnetic fields have been investigated. Both the high degree of Zeeman splitting of the resonant transitions and the ion rotational movement drastically change the properties of the resonance interaction of the continuous wave laser radiation with ions in highly magnetized plasma. Numerical solution of the density matrix equation for a dissipative two-level system with time-dependent detuning from resonance was used to analyse this interaction. A theoretical simulation was performed and compared with the experimental results obtained from the laser spectroscopy diagnostics of barium plasma ions in high magnetic fields in the several tesla range

  14. Waveguide based external cavity semiconductor lasers

    NARCIS (Netherlands)

    Oldenbeuving, Ruud; Klein, E.J.; Offerhaus, Herman L.; Lee, Christopher James; Verhaegen, M.; Boller, Klaus J.

    2012-01-01

    We report on progress of the project waveguide based external cavity semiconductor laser (WECSL) arrays. Here we present the latest results on our efforts to mode lock an array of tunable, external cavity semiconductor lasers.

  15. High resolution laser spectroscopy as a diagnostic tool in beams

    International Nuclear Information System (INIS)

    Bergmann, K.; Hefter, U.; Hering, P.

    1977-01-01

    The combination of high resolution laser spectroscopy with the technique of molecular beams allows a very detailed beam research since molecules or atoms in specific quantum states can be sampled yielding previously unavailable sources of data. In these experiments a Na/Na 2 beam emerges from a 0.2 mm nozzle and is collimated by a 2 mm wide slit 50 cm downstream. To probe the molecules a single mode Ar + -laser was used which can be tuned within the gain profile of the laser line (8 GHz) to several transitions between specific levels in the ground state and second electronically excited state of the Na 2 molecule. (Auth.)

  16. X-ray optical diagnostic of laser produced plasmas for nuclear fusion and X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Butzbach, R.

    2001-07-01

    In the present work, the conception, design and appliance of toroidally bent crystals for the X-ray optical diagnostics of laser produced plasmas is discussed. The first part of this work deals with the development, design and characterization of an X-Ray microscope for the observation of Rayleigh-Taylor instabilities, which act against the confinement and ignition of the fuel in the inertial confinement fusion process. The aim of the second part of the present work was the diagnostic of the lasing medium for amplified spontaneous emission close to the water window. For this purpose, an one-dimensionally (1-D) imaging X-ray spectrometer based on toroidally bent quartz crystals was developed for the observation of the Ni-like 4f-3d transition of Yb, Hf, Ta, and W ions, which should be related to the amplified 4d-4p emission, since the 4f niveau is very close to the 4d niveau. Thus, the 4f-3d transition can serve as an indicator for the population of the 4d niveau. (orig.)

  17. CO{sub 2} laser diagnostics for measurements of the plasma density profile and plasma density fluctuations on LHD

    Energy Technology Data Exchange (ETDEWEB)

    Vyacheslavov, L.N. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Tanaka, K.; Kawahata, K. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2001-04-01

    A CO{sub 2} laser based diagnostics complimentary to the existing FIR interferometer is proposed. It combines interferometry for plasma density profile measurement under conditions of large density gradients, and both imaging and scattering techniques for observation of plasma fluctuations. Two-colour interferometer with a slablike probe beam and a single multichannel linear detector array provide observation of plasma density profile and density fluctuations at two locations along the probe beam. Basic characteristics of the diagnostics are considered as well as some effects that include dispersion and are critical for two colour imaging technique. The results of the bench-top experiments with the prototype of the interferometer are presented. (author)

  18. CO2 laser diagnostics for measurements of the plasma density profile and plasma density fluctuations on LHD

    International Nuclear Information System (INIS)

    Vyacheslavov, L.N.; Tanaka, K.; Kawahata, K.

    2001-04-01

    A CO 2 laser based diagnostics complimentary to the existing FIR interferometer is proposed. It combines interferometry for plasma density profile measurement under conditions of large density gradients, and both imaging and scattering techniques for observation of plasma fluctuations. Two-colour interferometer with a slablike probe beam and a single multichannel linear detector array provide observation of plasma density profile and density fluctuations at two locations along the probe beam. Basic characteristics of the diagnostics are considered as well as some effects that include dispersion and are critical for two colour imaging technique. The results of the bench-top experiments with the prototype of the interferometer are presented. (author)

  19. Case-Based Fault Diagnostic System

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2014-01-01

    Nowadays, case-based fault diagnostic (CBFD) systems have become important and widely applied problem solving technologies. They are based on the assumption that “similar faults have similar diagnosis”. On the other hand, CBFD systems still suffer from some limitations. Common ones of them are: (1) failure of CBFD to have the needed diagnosis for the new faults that have no similar cases in the case library. (2) Limited memorization when increasing the number of stored cases in the library. The proposed research introduces incorporating the neural network into the case based system to enable the system to diagnose all the faults. Neural networks have proved their success in the classification and diagnosis problems. The suggested system uses the neural network to diagnose the new faults (cases) that cannot be diagnosed by the traditional CBR diagnostic system. Besides, the proposed system can use the another neural network to control adding and deleting the cases in the library to manage the size of the cases in the case library. However, the suggested system has improved the performance of the case based fault diagnostic system when applied for the motor rolling bearing as a case of study

  20. Laser-based coatings removal

    International Nuclear Information System (INIS)

    Freiwald, J.G.; Freiwald, D.A.

    1995-01-01

    Over the years as building and equipment surfaces became contaminated with low levels of uranium or plutonium dust, coats of paint were applied to stabilize the contaminants in place. Most of the earlier paint used was lead-based paint. More recently, various non-lead-based paints, such as two-part epoxy, are used. For D ampersand D (decontamination and decommissioning), it is desirable to remove the paints or other coatings rather than having to tear down and dispose of the entire building. This report describes the use of pulse-repetetion laser systems for the removal of paints and coatings

  1. Laser-based coatings removal

    Energy Technology Data Exchange (ETDEWEB)

    Freiwald, J.G.; Freiwald, D.A. [F2 Associates, Inc., Albuquerque, NM (United States)

    1995-10-01

    Over the years as building and equipment surfaces became contaminated with low levels of uranium or plutonium dust, coats of paint were applied to stabilize the contaminants in place. Most of the earlier paint used was lead-based paint. More recently, various non-lead-based paints, such as two-part epoxy, are used. For D&D (decontamination and decommissioning), it is desirable to remove the paints or other coatings rather than having to tear down and dispose of the entire building. This report describes the use of pulse-repetetion laser systems for the removal of paints and coatings.

  2. Laser-plasma based electron acceleration studies planned at CAT, Indore

    International Nuclear Information System (INIS)

    Naik, P.A.; Gupta, P.D.

    2005-01-01

    The Laser Plasma Division at the Centre for Advanced Technology is engaged in a variety of R and D activities on laser-plasma interaction with special emphasis on laser-matter interaction at ultra-high intensities. An important aspect of our future work is studies in laser-plasma based acceleration using an elaborate infrastructural set-up of ultra-fast laser and plasma diagnostic systems and recently acquired 10 TW, 50 fs Ti: Sapphire laser system. This paper presents outline of the planned studies in this field. (author)

  3. Plasma diagnostics using laser-excited coupled and transmission ring resonators

    International Nuclear Information System (INIS)

    Haas, R.A.

    1976-01-01

    In this paper a simple two-level laser model is used to investigate the frequency response of coupled-cavity laser interferometers. It is found that under certain circumstances, often satisfied by molecular gas lasers, the frequency response exhibits a resonant behavior. This behavior severely complicates the interpretation of coupled-cavity laser interferometer measurements of rapidly varying plasmas. To circumvent this limitation a new type of laser interferometer plasma diagnostic with significantly improved time response was developed. In this interferometer the plasma is located in one arm of a transmission ring resonator cavity that is excited by an externally positioned laser. Thus, the laser is decoupled from the interferometer cavity and the time response of the interferometer is then limited by the Q of the ring resonator cavity. This improved time response is acquired without loss of spatial resolution, but requires a more sensitive signal detector since the laser is no longer used as a detector as it is in conventional coupled-cavity laser interferometers. Thus, the new technique incorporates the speed of the Mach--Zender interferometer and the sensitivity of the coupled-cavity laser interferometer. The basic operating principles of this type of interferometer have been verified using a CO 2 laser

  4. Cleaning of the first mirrors and diagnostic windows by YAG laser on HL-2A

    International Nuclear Information System (INIS)

    Zhou, Y; Zheng, L; Li, Y G; Li, L C; Jiao, Y M; Gao, H; Zhao, G

    2009-01-01

    A laser cleaning system for HL-2A tokamak first mirrors and diagnostic windows has been developed recently. A detailed description of the laser cleaning procedure is presented. The optical transmission performance measured before and after the laser cleaning of the impurity film deposited on the optical elements is investigated. HL-2A deposited layers on metal mirrors and glass windows with thicknesses of about 1 and 4 μm, respectively, are clearly removed by irradiation with a single pulse of a Q-switched Nd:YAG laser with energy density of 0.4 and 2.8 J cm -2 , respectively. The feasibility of cleaning ECE windows is demonstrated. A cleaning time of about 5 min is suitable for application in fusion devices. The comparison of results obtained at different laser wavelengths shows that there is a greater probability of damage to the metallic mirror surface with a short laser wavelength than with longer wavelength.

  5. Evidence-based diagnostics: adult septic arthritis.

    Science.gov (United States)

    Carpenter, Christopher R; Schuur, Jeremiah D; Everett, Worth W; Pines, Jesse M

    2011-08-01

    Acutely swollen or painful joints are common complaints in the emergency department (ED). Septic arthritis in adults is a challenging diagnosis, but prompt differentiation of a bacterial etiology is crucial to minimize morbidity and mortality. The objective was to perform a systematic review describing the diagnostic characteristics of history, physical examination, and bedside laboratory tests for nongonococcal septic arthritis. A secondary objective was to quantify test and treatment thresholds using derived estimates of sensitivity and specificity, as well as best-evidence diagnostic and treatment risks and anticipated benefits from appropriate therapy. Two electronic search engines (PUBMED and EMBASE) were used in conjunction with a selected bibliography and scientific abstract hand search. Inclusion criteria included adult trials of patients presenting with monoarticular complaints if they reported sufficient detail to reconstruct partial or complete 2 × 2 contingency tables for experimental diagnostic test characteristics using an acceptable criterion standard. Evidence was rated by two investigators using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS). When more than one similarly designed trial existed for a diagnostic test, meta-analysis was conducted using a random effects model. Interval likelihood ratios (LRs) were computed when possible. To illustrate one method to quantify theoretical points in the probability of disease whereby clinicians might cease testing altogether and either withhold treatment (test threshold) or initiate definitive therapy in lieu of further diagnostics (treatment threshold), an interactive spreadsheet was designed and sample calculations were provided based on research estimates of diagnostic accuracy, diagnostic risk, and therapeutic risk/benefits. The prevalence of nongonococcal septic arthritis in ED patients with a single acutely painful joint is approximately 27% (95% confidence interval [CI] = 17

  6. Soft x-ray power diagnostic improvements at the Omega Laser Facility

    International Nuclear Information System (INIS)

    Sorce, C.; Schein, J.; Weber, F.; Widmann, K.; Campbell, K.; Dewald, E.; Turner, R.; Landen, O.; Jacoby, K.; Torres, P.; Pellinen, D.

    2006-01-01

    Soft x-ray power diagnostics are essential for evaluating high temperature laser plasma experiments. The Dante soft x-ray spectrometer, a core diagnostic for radiation flux and temperature measurements of Hohlraums, installed on the Omega Laser Facility at the Laboratory for Laser Energetics has recently undergone a series of upgrades. Work performed at Brookhaven National Laboratory for the development of the National Ignition Facility (NIF) Dante spectrometer enables the Omega Dante to offer a total of 18 absolutely calibrated channels in the energy range from 50 eV to 20 keV. This feature provides Dante with the capability to measure higher, NIF relevant, radiation temperatures with increased accuracy including a differentiation of higher energy radiation such as the Au M and L bands. Diagnostic monitoring using experimental data from directly driven Au spherical shots is discussed

  7. New photonuclear methods based on femtosecond lasers

    International Nuclear Information System (INIS)

    Ivanov, K.A.; Shulyapov, S.A.; Savel'ev, A.B.; Uryupina, D.S.; Volkov, R.V.; Rusakov, A.V.; Turinge, A.A.; Dzhilkibaev, R.M.; Nedorezov, V.G.; Brantov, A.V.; Bychenkov, V.Yu.

    2014-01-01

    Results of X-ray diagnostics of plasma created on the surface of matter by laser pulse with an intensity of 2.5 · 10 18 W/cm 2 are presented in the paper. Comparison of experimental data with the results of numerical simulation of laser-plasma interaction is made taking into account the response functions of the detector. Examples of possible nuclear tasks realizable with the use of laser plasma as a source of charged particles and X rays are given

  8. Laser-produced Au nanoparticles as X-ray contrast agents for diagnostic imaging

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Restuccia, N.; Cuzzocrea, S.; Paterniti, I.; Ielo, I.; Pergolizzi, S.; Cutroneo, Mariapompea; Kováčik, L.

    2017-01-01

    Roč. 50, č. 1 (2017), s. 51-60 ISSN 0017-1557 R&D Projects: GA MŠk LM2015056; GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : Au nanoparticles * Laser * X-ray diagnostic s * medical imaging * contrast medium Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.638, year: 2016

  9. A Study of Laser System Requirements for Application in Beam Diagnostics And Polarimetry at the ILC

    Energy Technology Data Exchange (ETDEWEB)

    Dixit, S.; Delerue, N.; Foster, B.; Howell, D.F.; Peach, K.; Quelch, G.; Qureshi, M.; Reichold, A.; /Oxford U.; Hirst, G.; Ross, I.; /Rutherford; Urakawa, J.; /KEK,; Soskov, V.; Variola, A.; Zomer, F.; /Orsay, LAL; Blair, G.A.; Boogert, S.T.; Boorman, G.; Bosco, A.; Driouichi, C.; Karataev, P.; /Royal Holloway, U. of London; Brachmann,; /SLAC

    2007-02-12

    Advanced laser systems will be essential for a range of diagnostics devices and polarimetry at the ILC. High average power, high beam quality, excellent stability and reliability will be crucial in order to deliver the information required to attain the necessary ILC luminosity as well as for efficient polarimetry. The key parameters are listed together with the R & D required to achieve the necessary laser system performance.

  10. Pulse-power circuit diagnostics for the Nova laser

    International Nuclear Information System (INIS)

    Christie, D.J.; Dallum, G.E.; Gritton, D.G.; Merritt, B.T.; Whitham, K.; Berkbigler, L.W.

    1982-01-01

    The Nova laser will have a large pulse power system for driving laser amplifiers, incorporating approximately 1600 flashlamp circuits. An automated system has been designed for diagnosing the condition of these flashlamp circuits. It records digitized circuit current waveforms and detects current excursions above a given threshold. In addition, it is able to fire flashlamps at a low energy to ascertain the health of the system. Data from this system can be ploted for inspection by the operator, analyzed by the computer system and archived for future reference

  11. Diagnostic measurements related to laser driven inertial confinement fusion

    International Nuclear Information System (INIS)

    Campbell, D.E.

    1979-01-01

    Scientists at the Lawrence Livermore Laboratory have been conducting laser driven inertial confinement fusion experiments for over five years. The first proof of the thermonuclear burn came at the Janus target irradiation facility in the spring of 1975. Since that time three succeedingly higher energy facilities have been constructed at Livermore, Cyclops, Argus and Shiva, where increased fusion efficiency has been demonstrated. A new facility, called Nova, is now in the construction phase and we are hopeful that scientific break even (energy released compared to incident laser energy on target) will be demonstrated here in early 1980's. Projected progress of the Livermore program is shown

  12. Laser cleaning of pulsed laser deposited rhodium films for fusion diagnostic mirrors

    International Nuclear Information System (INIS)

    Uccello, A.; Maffini, A.; Dellasega, D.; Passoni, M.

    2013-01-01

    Highlights: ► Pulsed laser deposition is exploited to produce Rh films for first mirrors. ► Pulsed laser deposition is exploited to produce tokamak-like C contaminants. ► Rh laser damage threshold has been evaluated for infrared pulses. ► Laser cleaning of C contaminated Rh films gives promising results. -- Abstract: In this paper an experimental investigation on the laser cleaning process of rhodium films, potentially candidates to be used as tokamak first mirrors (FMs), from redeposited carbon contaminants is presented. A relevant issue that lowers mirror's performance during tokamak operations is the redeposition of sputtered material from the first wall on their surface. Among all the possible techniques, laser cleaning, in which a train of laser pulses is launched to the surface that has to be treated, is a method to potentially mitigate this problem. The same laser system (Q-switched Nd:YAG laser with a fundamental wavelength of 1064-nm and 7-ns pulses) has been employed with three aims: (i) production by pulsed laser deposition (PLD) of Rh film mirrors, (ii) production by PLD of C deposits with controlled morphology, and (iii) investigation of the laser cleaning method onto C contaminated Rh samples. The evaluation of Rh films laser damage threshold, as a function of fluence and number of pulses, is discussed. Then, the C/Rh films have been cleaned by the laser beam. The exposed zones have been characterized by visual inspection and scanning electron microscopy (SEM), showing promising results

  13. X radiation diagnostics of high-temperature laser plasma

    International Nuclear Information System (INIS)

    Marsak, Z.; Bryknar, Z.; Legova, S.; Pina, L.

    1980-01-01

    Main aspects of X-ray emission from plasma heated by a pulsed laser and methods of its detection are presented, especially using a pinhole camera and a multichannel spectrometer with p-i-n diodes and Be-filters for measurement in the energy range 0.5 keV to 3 keV. (author)

  14. Diode Laser Diagnostics of High Speed Flows (Postprint)

    National Research Council Canada - National Science Library

    Williams, Skip; Barone, Dominic; Barhorst, Todd; Jackson, Kevin; Lin, K. C; Masterson, Pat; Zhao, Qingchun; Sappey, Andrew D

    2006-01-01

    ... of 60,000-90,000 ft with an average Mach number of 7.5 over this range. The concept involves the direct measurement of oxygen concentration via absorption spectroscopy, and gas velocity via the Doppler shift of laser light transiting the flowpath...

  15. Compact laser-diode-based femtosecond sources

    International Nuclear Information System (INIS)

    Brown, C T A; Cataluna, M A; Lagatsky, A A; Rafailov, E U; Agate, M B; Leburn, C G; Sibbett, W

    2004-01-01

    This paper describes the development of compact femtosecond laser systems that are capable of being directly pumped by laser diodes or are based directly on laser diodes. The paper demonstrates the latest results in a highly efficient vibronic based gain medium and a diode-pumped Yb:KYW laser is reported that has a wall plug efficiency >14%. A Cr 4+ :YAG oscillator is described that generates transform-limited pulses of 81 fs duration at a pulse repetition frequency of >4 GHz. The development of Cr 3+ :LiSAF lasers that can be operated using power supplies based on batteries is briefly discussed. We also present a summary of work being carried out on the generation of fs-pulses from laser diodes and discuss the important issues in this area. Finally, we outline results obtained on the generation of pulses as short as 550 fs directly from a two-section quantum dot laser without any external pulse compression

  16. Divergence-based tests for model diagnostic

    Czech Academy of Sciences Publication Activity Database

    Hobza, Tomáš; Esteban, M. D.; Morales, D.; Marhuenda, Y.

    2008-01-01

    Roč. 78, č. 13 (2008), s. 1702-1710 ISSN 0167-7152 R&D Projects: GA MŠk 1M0572 Grant - others:Instituto Nacional de Estadistica (ES) MTM2006-05693 Institutional research plan: CEZ:AV0Z10750506 Keywords : goodness of fit * devergence statistics * GLM * model checking * bootstrap Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.445, year: 2008 http://library.utia.cas.cz/separaty/2008/SI/hobza-divergence-based%20tests%20for%20model%20diagnostic.pdf

  17. Electron bunch diagnostics for laser-plasma accelerators, from THz to X-rays

    International Nuclear Information System (INIS)

    Plateau, G.

    2011-10-01

    This thesis presents a series of single-shot non-intrusive diagnostics of key attributes of electron bunches produced by a laser-plasma accelerator (LPA). Three injection mechanisms of the LPA are characterized: channeled and self-guided self-injection, plasma down-ramp injection, and two-beam colliding pulse injection. New diagnostic techniques are successfully demonstrated: up to 8 times higher sensitivity wavefront sensor-based plasma density measurements, strong spatio-temporal coupling of the focused THz pulse is demonstrated using the temporal electric-field cross-correlation (TEX) of a long chirped probe with a short probe and confirms the two-component structure of the bunch observed by electron spectrometry, and normalized transverse emittances as low as 0.1 mm mrad are demonstrated for 0.5 GeV-class beams produced in a capillary-guided LPA by characterizing the betatron radiation emitted by the electrons inside the plasma using a new single-shot X-ray spectroscopy technique. (author)

  18. Laser-based optical detection of explosives

    CERN Document Server

    Pellegrino, Paul M; Farrell, Mikella E

    2015-01-01

    Laser-Based Optical Detection of Explosives offers a comprehensive review of past, present, and emerging laser-based methods for the detection of a variety of explosives. This book: Considers laser propagation safety and explains standard test material preparation for standoff optical-based detection system evaluation Explores explosives detection using deep ultraviolet native fluorescence, Raman spectroscopy, laser-induced breakdown spectroscopy, reflectometry, and hyperspectral imaging Examines photodissociation followed by laser-induced fluorescence, photothermal methods, cavity-enhanced absorption spectrometry, and short-pulse laser-based techniques Describes the detection and recognition of explosives using terahertz-frequency spectroscopic techniques Each chapter is authored by a leading expert on the respective technology, and is structured to supply historical perspective, address current advantages and challenges, and discuss novel research and applications. Readers are left with an in-depth understa...

  19. Photon acceleration versus frequency-domain interferometry for laser wakefield diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dias, J M; Oliveira e Silva, L; Mendonca, J T [GoLP/Centro de Fisica de Plasmas, Inst. Superior Tecnico, Lisbon (Portugal)

    1998-03-01

    A detailed comparison between the photon acceleration diagnostic technique and the frequency-domain interferometric technique for laser wakefield diagnostics, by using ray-tracing equations is presented here. The dispersion effects on the probe beam and the implications of an arbitrary phase velocity of the plasma wave are discussed for both diagnostic techniques. In the presence of large amplitude plasma wave and long interaction distances significant frequency shifts can be observed. The importance of this effect on the determination of the phase and frequency shifts measurements given by each of the two diagnostic techniques, is also analyzed. The accuracy of both diagnostic techniques is discussed and some of their technical problems are reviewed. (author)

  20. Application of mid-infrared tuneable diode laser absorption spectroscopy to plasma diagnostics: a review

    International Nuclear Information System (INIS)

    Roepcke, J; Lombardi, G; Rousseau, A; Davies, P B

    2006-01-01

    Within the last decade mid-infrared absorption spectroscopy over a region from 3 to 17μm and based on tuneable lead salt diode lasers, often called tuneable diode laser absorption spectroscopy or TDLAS, has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry in molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has led to further applications of TDLAS because most of these compounds and their decomposition products are infrared active. TDLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetic phenomena. Information about gas temperature and population densities can also be derived from TDLAS measurements. A variety of free radicals and molecular ions have been detected by TDLAS. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of quantum cascade lasers (QCLs) offers an attractive new option for the monitoring and control of industrial plasma processes. The aim of the present paper is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid-infrared

  1. Application of Advanced Laser Diagnostics to High-Impact Technologies: Science and Applications of Ultrafast, Ultraintense Lasers

    Science.gov (United States)

    2013-11-01

    near the dense spray region of a fuel nozzle that is used in diesel engines [Powell et al., 2003]. Several years ago we made an unsuccessful attempt...12: Drilled and shaped Silicon Carbide. The cutting of nozzle shapes for fuel injectors was also investigated. The machining algorithm was...possible previously [Poola et al., 2000]. The problem has been that conventional laser diagnostics could not penetrate the near- nozzle opaque region of

  2. Laser Spot Detection Based on Reaction Diffusion.

    Science.gov (United States)

    Vázquez-Otero, Alejandro; Khikhlukha, Danila; Solano-Altamirano, J M; Dormido, Raquel; Duro, Natividad

    2016-03-01

    Center-location of a laser spot is a problem of interest when the laser is used for processing and performing measurements. Measurement quality depends on correctly determining the location of the laser spot. Hence, improving and proposing algorithms for the correct location of the spots are fundamental issues in laser-based measurements. In this paper we introduce a Reaction Diffusion (RD) system as the main computational framework for robustly finding laser spot centers. The method presented is compared with a conventional approach for locating laser spots, and the experimental results indicate that RD-based computation generates reliable and precise solutions. These results confirm the flexibility of the new computational paradigm based on RD systems for addressing problems that can be reduced to a set of geometric operations.

  3. Laser Spot Detection Based on Reaction Diffusion

    Directory of Open Access Journals (Sweden)

    Alejandro Vázquez-Otero

    2016-03-01

    Full Text Available Center-location of a laser spot is a problem of interest when the laser is used for processing and performing measurements. Measurement quality depends on correctly determining the location of the laser spot. Hence, improving and proposing algorithms for the correct location of the spots are fundamental issues in laser-based measurements. In this paper we introduce a Reaction Diffusion (RD system as the main computational framework for robustly finding laser spot centers. The method presented is compared with a conventional approach for locating laser spots, and the experimental results indicate that RD-based computation generates reliable and precise solutions. These results confirm the flexibility of the new computational paradigm based on RD systems for addressing problems that can be reduced to a set of geometric operations.

  4. A multi-laser system for a fast sampling Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Trost, P.K.; Carlstrom, T.N.; DeBoo, J.C.; Greenfield, C.M.; Hsieh, C.L.; Snider, R.T.

    1990-10-01

    A multi-laser system is being developed for the DIII-D Thomson scattering diagnostic. This system combines the beams from up to eight Nd:YAG lasers onto a common beamline in which the beams are nearly parallel and are all focused into a small, common area within the desired scattering volume. Each laser can be fired at a constant rate (20 Hz per laser) for a high average repetition rate, or together in a ''burst,'' which will give very high sampling rates (10--20 kHz) for short periods. The burst mode will be triggerable by plasma events, which will allow for study of transient phenomena, but will require non-periodic firing of the lasers. Beamline diagnostics include position sensitive detectors for computer controlled feedback alignment of the 35 m beamline, an image position detection system for monitoring the alignment of the collection lens to the scattering volume, and a 1-D reticon camera for divergence monitoring. The effects of the non-periodic firing of the lasers will be monitored with the reticon camera. 3 refs., 5 figs

  5. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. [Texas Univ., Houston, TX (United States). Cancer Center; Welch, A.J. [Texas Univ., Austin, TX (United States); Motamedi, M. [Texas Univ., Galveston, TX (United States). Medical Branch; Rastegar, S. [Texas A and M Univ., College Station, TX (United States); Tittel, F. [Rice Univ., Houston, TX (United States); Esterowitz, L. [Naval Research Lab., Washington, DC (United States)

    1992-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the colloborating engineering centers at Rice University, UT-Austin, and Texas A&M Univ. In addition, this collective is collaborating with the Naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  6. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. (Texas Univ., Houston, TX (United States). Cancer Center); Welch, A.J. (Texas Univ., Austin, TX (United States)); Motamedi, M. (Texas Univ., Galveston, TX (United States). Medical Branch); Rastegar, S. (Texas A and M Univ., College Station, TX (United States)); Tittel, F. (Rice Univ., Houston, TX (United States)); Esterowitz, L. (Naval Research Lab., Washington, DC (United States))

    1992-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the colloborating engineering centers at Rice University, UT-Austin, and Texas A M Univ. In addition, this collective is collaborating with the Naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  7. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. [Texas Univ., Houston, TX (United States). Cancer Center; Welch, A.J. [Texas Univ., Austin, TX (United States); Motamedi, M. [Texas Univ., Galveston, TX (United States). Medical Branch; Rastegar, S. [Texas A and M Univ., College Station, TX (United States); Tittel, F. [Rice Univ., Houston, TX (United States); Esterowitz, L. [Naval Research Lab., Washington, DC (United States)

    1993-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the collaborating engineering enters at Rice University, UT-Austin, Texas A&M Univ. In addition, this collective is collaborating with the naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  8. Design process for NIF laser alignment and beam diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Grey, A., LLNL

    1998-06-09

    In a controller for an adaptive optic system designed to correct phase aberrations in a high power laser, the wavefront sensor is a discrete Hartmann-Shack design. It uses an army of lenslets (like a fly` s eye) to focus the laser into 77 spots on a CCD camera. Average local tilt of the wavefront across each lenslet changes the position of its focal spot. The system requires 0.1 pixel accuracy in determining the focal spot location. We determine a small area around each spot` s previous location. Within this area, we calculate the centroid of the light intensity in x and y. This calculation fails if the spot regions overlap. Especially during initial acquisition of a highly distorted beam, distinguishing overlapping spots is difficult. However, low resolution analysis of the overlapping spots allows the system to estimate their positions. With this estimate, it can use the deformable mirror to correct the beam enough so we can detect the spots using conventional image processing.

  9. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R; O'Brien, D; Nelson, J; Kamperschroer, J

    2007-01-01

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the deployed

  10. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; O' Brien, D; Nelson, J; Kamperschroer, J

    2007-05-07

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the

  11. Infrared laser scattering system for the plasma diagnostics: CO/sub 2/ laser characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, N; Kawasaki, S; Muraoka, K

    1975-08-01

    A detailed study was conducted of the operating characteristics of a double discharge infrared TEA carbon dioxide laser used for scattering measurements of plasmas. The discharge condition, the laser output energy and power, the beam profile and divergence, the emission spectral line width, the time lag and jitter of the output from the discharge trigger, have been established. It is concluded that the carbon dioxide oscillator can deliver the allowable beam divergence and spectral line width for the measurement of ion temperature in light scattering studies of theta pinch plasmas. The results presented might be applicable to laser fusion experiments using carbon dioxide lasers.

  12. X-ray diodes for laser fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Day, R.H.; Lee, P.; Saloman, E.B.; Nagel, D.J.

    1981-02-01

    Photodiodes with x-ray sensitive photocathodes are commonly used as broadband x-ray detectors in fusion plasma diagnostics. We have measured the risetime of the detector system and have measured the quantum efficiency between 1 to 500 A of numerous photocathode materials of practical interest. The materials studied include aluminum, copper, nickel, gold, three forms of carbon, chromium, and cesium iodide. The results of the measurements are compared with Henke's semiempirical model of photoyield. We have studied the effects of long-term cathode aging and use as a plasma diagnostic on cathode quantum efficiency. In addition, we have measured the x-ray mass-absorption coefficient of several ultrasoft x-ray windows in energy regions where data were unavailable. Windows studied were made of aluminum, Formvar, polypropylene, and Kimfoil. Measurements between 1 to 50 A were performed with the Los Alamos Scientific Laboratory's low-energy x-ray calibration facility, and the measurements between 50 to 550 A were performed at the National Bureau of Standard's synchrotron ultraviolet radiation facility

  13. Laser diagnodent: a comparative study with other diagnostic techniques

    International Nuclear Information System (INIS)

    Godinho, Reugma Rego

    2002-01-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  14. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  15. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Patel, Kiran; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-01-01

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  16. A twin optically-pumped far-infrared CH3OH laser for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, M.; Takeda, Y.; Tanigawa, S.; Nishizawa, A.; Noda, N.

    1979-11-01

    A twin optically-pumped far-infrared CH 3 OH laser has been constructed for use in plasma diagnostics. The anti-symmetric doublet due to the Raman-type resonant two-photon transition is reproducibly observed at 118.8 μm. With the 118.8-μm line, it is obtained from the frequency separation of the anti-symmetric doublet that the CH 3 OH absorption line center is 16 +- 1 MHz higher than the pump 9.7-μm P(36) CO 2 laser line center. It is shown that the Raman-type resonant two-photon transition is useful in order to get several-MHz phase modulation for the far-infrared laser interferometer. Some preliminary performances of this twin laser for the modulated interferometer are described. (author)

  17. Twin optically-pumped far-infrared CH3OH laser for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, M.; Takeda, Y.; Tanigawa, S.; Nishizawa, A.

    1980-01-01

    A twin optically-pumped far-infrared CH 3 OH laser has been constructed for use in plasma diagnostics. The antisymmetric doublet due to the Raman-type resonant two-photon transition is reproducibly observed at 118.8 microns. With the 118.8-micron line, it is found that CH 3 OH absorption line center is 16 + or - 1 MHz higher than the pump 9.7-micron P(36) CO 2 laser line center. It is shown that the Raman-type resonant two-photon transition is useful in order to get several MHz phase modulation for the far-infrared laser interferometer. Some preliminary performances of this twin laser for the modulated interferometer are described

  18. Satellite-based laser windsounder

    International Nuclear Information System (INIS)

    Schultz, J.F.; Czuchlewski, S.J.; Quick, C.R.

    1997-01-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project''s primary objective is to determine the technical feasibility of using satellite-based laser wind sensing systems for detailed study of winds, aerosols, and particulates around and downstream of suspected proliferation facilities. Extensive interactions with the relevant operational organization resulted in enthusiastic support and useful guidance with respect to measurement requirements and priorities. Four candidate wind sensing techniques were evaluated, and the incoherent Doppler technique was selected. A small satellite concept design study was completed to identify the technical issues inherent in a proof-of-concept small satellite mission. Use of a Mach-Zehnder interferometer instead of a Fabry-Perot would significantly simplify the optical train and could reduce weight, and possibly power, requirements with no loss of performance. A breadboard Mach-Zehnder interferometer-based system has been built to verify these predictions. Detailed plans were made for resolving other issues through construction and testing of a ground-based lidar system in collaboration with the University of Wisconsin, and through numerical lidar wind data assimilation studies

  19. Spatial diagnostics of the laser induced lithium fluoride plasma

    Energy Technology Data Exchange (ETDEWEB)

    Baig, M. A.; Qamar, Aisha; Fareed, M. A.; Anwar-ul-Haq, M.; Ali, Raheel [Atomic and Molecular Physics Laboratory, Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan)

    2012-06-15

    We present spatial characteristics of the lithium fluoride plasma generated by the fundamental and second harmonic of a Nd:YAG laser. The plume emission has been recorded spatially using five spectrometers covering the spectral region from 200 nm to 720 nm. The electron density is measured from the Stark broadened line profile of the line at 610.37 nm, whereas the plasma temperature has been determined using the Boltzmann plot method including all the observed spectral lines of lithium. Both the plasma parameters; electron density and plasma temperature decrease with the increase of the distance from the target surface. The thermal conduction towards the target, the radiative cooling of the plasma, and the conversion of thermal energy into kinetic energy are the main mechanisms responsible for the spatially decrease of the plasma parameters.

  20. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  1. Diode pumped solid state kilohertz disk laser system for time-resolved combustion diagnostics under microgravity at the drop tower Bremen

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Volker; Paa, Wolfgang; Triebel, Wolfgang [Institute of Photonic Technology, Laser Diagnostics, Albert-Einstein-Str. 9, 07745 Jena (Germany); Eigenbrod, Christian; Klinkov, Konstantin [Center of Applied Space Technology and Microgravity, University Bremen, Am Fallturm, 28359 Bremen (Germany); Larionov, Mikhail; Giesen, Adolf; Stolzenburg, Christian [Institut für Strahlwerkzeuge (IFSW), Pfaffenwaldring 43, 70569 Stuttgart (Germany)

    2014-03-15

    We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic around 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.

  2. Optical diagnostics of lead and PbGa2S4 layered crystal laser plasmas

    International Nuclear Information System (INIS)

    Shuaibov, A.K.; Dashchenko, A.I.; Shevera, I.V.

    2001-01-01

    Laser plasmas produced at the surfaces of lead and a PbGa 2 S 4 layered crystal irradiated by a neodymium laser with λ = 1.06 μm, pulse duration τ = 20 ns, and intensity W = (1-2) x 10 9 W/cm 2 are studied using optical diagnostics. It is shown that, in a lead plasma, the most intense (characteristic) lines are the PbI 405.7-nm, PbI 368.3-nm, PbI 364-nm, and PbII 220.4-nm lines. In a layered crystal plasma, the emission spectrum is an aggregation of the most intense PbI and GaI lines, whereas sulfur lines are absent. The bottlenecks of the recombination of the ionic and atomic components of the lead and PbGa 2 S 4 crystal plasmas are determined. The average propagation velocity of the lead laser plume is 18-20 km/s. A comparative analysis of the emission dynamics of PbI and GaI lines in the laser plasmas of these metals and in the plasma of a PbGa 2 S 4 crystal is carried out. The results obtained are important for the optical diagnostics of the plasmas of lead- and gallium-containing crystals and for the optimization of laser deposition of the thin films of these substances

  3. Field-based systems and advanced diagnostics

    International Nuclear Information System (INIS)

    Eryurek, E.

    1998-01-01

    Detection and characterization of anomalies in an industrial plant provide improved plant availability and plant efficiency thus yielding increased economic efficiency. Traditionally, detection of process anomalies is done at a high-level control system through various signal validation methods. These signal validation techniques rely on data from transmitters, which measure related process variables. Correlating these signals and deducing anomalies often is a very time consuming and a difficult task. Delays in detecting these anomalies can be costly during plant operation. Conventional centralized approaches also suffer from their dependence on detailed mathematical models of the processes. Smart field devices have the advantage of providing the necessary information directly to the control system as anomalies develop during operation of the processes enabling operators to take necessary steps to either prevent an unnecessary shut down before the problem becomes serious or schedule maintenance on the problematic loop. Fisher-Rosemount's PlantWeb TM architecture addresses 'Enhanced Measurement, Advanced Diagnostics and Control in the Field'. PlantWeb TM builds open process management systems by networking intelligent field devices, scalable control and systems platforms, and integrated modular software. A description of PlantWeb TM and how it improves various process conditions and reduces operating cost of a plant as well as a high level description of 'Enhanced Measurement, Advanced Diagnostics and Control in the Field', will be provided in this paper. PlantWeb TM is the trademark for Fisher-Rosemount's new field-based architecture that uses emerging technologies to utilize the power of intelligent field devices and deliver critical process and equipment information to improve plant performance. (author)

  4. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G; Meglinski, I V

    2014-01-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  5. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  6. Vulnerability analysis of DT fusion diagnostics for laser Megajoule facility. A new tool: Diacad; Analyse de vulnerabilite de chaines de diagnostic pour la fusion DT dans le cadre du laser megajoule. Un nouvel outil: diacad

    Energy Technology Data Exchange (ETDEWEB)

    D' hose, C.; Baggio, J.; Musseau, O. [CEA Bruyeres-le-Chatel, 91 (France)

    1999-07-01

    The Megajoule laser (LMJ) project is a major component of the French simulation program to study inertial confinement. This new facility will provide an energy 60 times greater than the largest lasers presently available (Phebus, Nova, Omega). Many diagnostic links will have to be developed in order to acquire complementary knowledge in this domain. A computer based tool has been defined. This paper presents the most recent developments of this new CAD (computer assisted diagnosis) tool. We first describe LMJ context, and then the analysis methodology developed to address the sensitivity to transient radiation of nuclear diagnosis links. This tool takes into account the vulnerability of individual parts and the global structure of the link. (A.C.)

  7. Gaseous laser targets and optical diagnostics for studying compressible hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Edwards, J M; Robey, H; Mackinnon, A

    2001-01-01

    Explore the combination of optical diagnostics and gaseous targets to obtain important information about compressible turbulent flows that cannot be derived from traditional laser experiments for the purposes of V and V of hydrodynamics models and understanding scaling. First year objectives: Develop and characterize blast wave-gas jet test bed; Perform single pulse shadowgraphy of blast wave interaction with turbulent gas jet as a function of blast wave Mach number; Explore double pulse shadowgraphy and image correlation for extracting velocity spectra in the shock-turbulent flow interaction; and Explore the use/adaptation of advanced diagnostics

  8. A laser-spectroscopy complex for fluorescent diagnostics and photodynamic therapy of age-related macula degeneration

    Science.gov (United States)

    Shevchik, S. A.; Meerovich, Gennadii A.; Budzinskaya, M. V.; Ermakova, N. A.; Kharnas, Sergey S.; Loschenov, Victor B.

    2004-06-01

    A laser-spectroscopy complex was developed for fluorescent diagnostics and photodynamic therapy of age related macula degeneration using the Russian photosensitizer Photosense. The complex is based on slit lamp which was additionally equipped with an optical adapter, and the video adapter allows to combine the procedure of photodynamic therapy and the control of its carrying in the frame work of one procedure. The sensitivity and spatial resolution of the complex were investigated using a special test object. The availability of the developed complex and Photosense itself was examined on experimental animals.

  9. Development of a non-contact diagnostic tool for high power lasers

    Science.gov (United States)

    Simmons, Jed A.; Guttman, Jeffrey L.; McCauley, John

    2016-03-01

    High power lasers in excess of 1 kW generate enough Rayleigh scatter, even in the NIR, to be detected by silicon based sensor arrays. A lens and camera system in an off-axis position can therefore be used as a non-contact diagnostic tool for high power lasers. Despite the simplicity of the concept, technical challenges have been encountered in the development of an instrument referred to as BeamWatch. These technical challenges include reducing background radiation, achieving high signal to noise ratio, reducing saturation events caused by particulates crossing the beam, correcting images to achieve accurate beam width measurements, creating algorithms for the removal of non-uniformities, and creating two simultaneous views of the beam from orthogonal directions. Background radiation in the image was reduced by the proper positioning of the back plane and the placement of absorbing materials on the internal surfaces of BeamWatch. Maximizing signal to noise ratio, important to the real-time monitoring of focus position, was aided by increasing lens throughput. The number of particulates crossing the beam path was reduced by creating a positive pressure inside BeamWatch. Algorithms in the software removed non-uniformities in the data prior to generating waist width, divergence, BPP, and M2 results. A dual axis version of BeamWatch was developed by the use of mirrors. By its nature BeamWatch produced results similar to scanning slit measurements. Scanning slit data was therefore taken and compared favorably with BeamWatch results.

  10. Development of laser-induced fluorescence for precombustion diagnostics in spark-ignition engines

    Energy Technology Data Exchange (ETDEWEB)

    Neij, H.

    1998-11-01

    ) - was investigated with respect to optical properties relevant to laser-based combustion diagnostics, by flame emission, optical absorption, laser-induced fluorescence, spontaneous Raman scattering, and rotational CARS. The potential for LIF detection of water vapor in combustion processes was evaluated. Water molecules were excited in a two-photon process at 248 nm yielding fluorescence around 400-500 nm. Spectrally interfering species at flame conditions were identified as hot O{sub 2}, and laser-generated C{sub 2} and N{sub 2}{sup +}. The detection limit for two-dimensional single-shot detection of water vapor at atmospheric conditions was estimated to 0.2%. Extrapolations to flame conditions were presented. A pressure-dependent process was identified, which decreased the signal intensity, broadened the linewidths, and degraded the spectral-excitation feature as the ambient pressure was increased. Two-photon water vapor LIF was applied to a research engine for residual gas visualization. The accuracy and precision of both two-dimensional and spatially averaged data were discussed. The LIF data was used to explain the engine behavior on a cycle-by-cycle basis. A significant correlation was identified between the combustion event and the spatially averaged water signal around the spark gap at the time of ignition 181 refs, 26 figs, 7 tabs

  11. Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge

    International Nuclear Information System (INIS)

    Tafalla, D.; Cal, E. de la; Tabares, F. L.

    1994-01-01

    A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, the density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength, bandwidth and energy profile and Rayleigh scattering in N2 was used for the optical system calibration. An absolute density of Cr atoms of n ∼ 5x10 cm was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal us. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma. (Author) 19 refs

  12. Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge

    International Nuclear Information System (INIS)

    Tafalla, D.; Cal, E. de la; Tabares, F.L.

    1994-01-01

    A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, The density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength bandwidth and energy profile and Rayleigh scattering in N 2 was used for the optical system calibration. An absolute density of Cr atoms of n= 5x10''9 cm''-3 was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal US. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma

  13. Ultrashort laser-pulse diagnostics for detection of ordering within an ion beam

    International Nuclear Information System (INIS)

    Calabrese, R.; Guidi, V.; Lenisa, P.; Mariotti, E.

    1996-01-01

    A novel diagnostic method to detect ordering within one-dimensional ion beams in a storage ring is presented. The ions are simultaneously excited by a ultrashort pulsed laser (≅1 ps) at two different locations along the beam and fluorescence is detected by a group of four photomultipliers. Correlation in fluorescence signals is a firm indication that the ion beam has an ordered structure. (orig.)

  14. High-energy resolution Thomson Parabola spectrometer for laser plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Cuttone, G.; Romano, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Maggiore, M. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague, Czech Republic and Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Ter-Avetisyan, S. [Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Tramontana, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and School of Mathematics and Physics, The Queen' s University Belfast, BT7 1NN (United Kingdom); Velyhan, A. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic)

    2013-07-26

    Thomson Parabola (TP) spectrometers are widely used devices for laser-driven beam diagnostics as they provide a complete set of information on the accelerated particles. A novel TP has been developed at LNS with a design able to detect protons up to 20 MeV. The layout design and some results obtained during the experimental campaign at PALS laboratory will be reported in the following.

  15. A pin diode x-ray camera for laser fusion diagnostic imaging: Final technical report

    International Nuclear Information System (INIS)

    Jernigan, J.G.

    1987-01-01

    An x-ray camera has been constructed and tested for diagnostic imaging of laser fusion targets at the Laboratory for Laser Energetics (LLE) of the University of Rochester. The imaging detector, developed by the Hughes Aircraft Company, is a germanium PIN diode array of 10 x 64 separate elements which are bump bonded to a silicon readout chip containing a separate low noise amplifier for each pixel element. The camera assembly consists of a pinhole alignment mechanism, liquid nitrogen cryostat with detector mount and a thin beryllium entrance window, and a shielded rack containing the analog and digital electronics for operations. This x-ray camera has been tested on the OMEGA laser target chamber, the primary laser target facility of LLE, and operated via an Ethernet link to a SUN Microsystems workstation. X-ray images of laser targets are presented. The successful operation of this particular x-ray camera is a demonstration of the viability of the hybrid detector technology for future imaging and spectroscopic applications. This work was funded by the Department of Energy (DOE) as a project of the National Laser Users Facility (NLUF)

  16. Laser Thomson scattering diagnostics of non-equilibrium high pressure plasmas

    International Nuclear Information System (INIS)

    Muraoka, K.; Uchino, K.; Bowden, M.D.; Noguchi, Y.

    2001-01-01

    For various applications of non-equilibrium high pressure plasmas, knowledge of electron properties, such as electron density, electron temperature and/or electron energy distribution function (eedf), is prerequisite for any rational approach to understanding physical and chemical processes occurring in the plasmas. For this purpose, laser Thomson scattering has been successfully applied for the first time to measure the electron properties in plasmas for excimer laser pumping and in microdischarges. Although this diagnostic technique is well established for measurements in high temperature plasmas, its applications to these glow discharge plasmas have had various inherent difficulties, such as a presence of high density neutral particles (>10 21 m -3 ) in the excimer laser pumping discharges and an extremely small plasma size (<0.1 mm) and the presence of nearby walls for microdischarges. These difficulties have been overcome and clear signals have been obtained. The measured results are presented and their implications in the respective discharge phenomena are discussed

  17. Diagnostics for the laser fusion program: plasma physics on the scale of microns and picoseconds

    International Nuclear Information System (INIS)

    Attwood, D.T.

    1978-01-01

    Laser induced fusion is the forerunner of a class of inertial confinement schemes in which hydrogen isotopes are heated to thermonuclear conditions in a very short period. The process is characterized by such short time scales that fuel confinement is achieved through its' own finite mass and expansion velocity, approaching 1 μm/psec for ignition temperatures of order 10 keV (10 8 0 K). With current laser powers limited to several terrawatts one readily estimates, on the basis of energy conservation, target mass, and expansion velocity, that target size and laser pulse duration are on the order of 100 μm and 100 psec, respectively. Within these constraints, targets have been heated and confined to the point where thermonuclear conditions have been achieved. This paper describes a sampling of diagnostic techniques with requisite resolution (microns and picoseconds) to accurately describe the dynamics of a laser driven compression. As discussed in each case cited, these in turn provide insight to and quantitative measure of, the physical processes dominating the implosion. The success of the inertial confinement fusion program is strongly dependent on the continued development of such diagnostics and the understanding they provide

  18. The Brief Introduction of Different Laser Diagnostics Methods Used in Aeroengine Combustion Research

    Directory of Open Access Journals (Sweden)

    Fei Xing

    2016-01-01

    Full Text Available Combustion test diagnosis has always been one of the most important technologies for the development of aerospace engineering. The traditional methods of measurement have been unable to meet the requirements of accurate capture of the flow field in the development process of the aeroengine combustor. Therefore, the development of high-precision measurement and diagnostic techniques to meet the needs of the aeroengine combustor design is imperative. Laser diagnostics techniques developed quickly in the past several years. They are used to measure the parameters of the combustion flow field such as velocity, temperature, and components concentration with high space and time resolution and brought no disturbance. Planar laser-induced fluorescence, coherent anti-Stokes Raman scattering, tunable diode laser absorption spectroscopy, and Raman scattering were introduced systemically in this paper. After analysis of their own advantages and disadvantages, the authors considered validated Raman scattering system and Tunable Diode Laser Absorption Tomography are more suitable for research activities on aeroengine combustion systems.

  19. Laser based refurbishment of steel mill components

    CSIR Research Space (South Africa)

    Kazadi, P

    2006-03-01

    Full Text Available Laser refurbishment capabilities were demonstrated and promising results were obtained for repair of distance sleeves, foot rolls, descaler cassette, idler rolls. Based on the cost projections and the results of the in-situ testing, components which...

  20. Laser diagnostic technology for early detection of pathogen infestation in orange fruits

    International Nuclear Information System (INIS)

    Giubileo, Gianfranco; Lai, Antonella; Piccinelli, Delinda; Puiu, Adriana

    2010-01-01

    Due to an increased expectation of food products that respect high quality and safety standards, there is a need for the growth of accurate, fast, objective and non-destructive technologies for quality determination of food and agricultural products. For this purpose, a diagnostic system based on laser photoacoustic spectroscopy (LPAS) was developed at ENEA Frascati Molecular Spectroscopy Laboratory (Italy). In the design of the photoacoustic detector, particular emphasis was placed in attaining a high sensitivity in detecting ethylene (ET) down to sub-parts per billion level (minimum detectable concentration 0.2 ppb). This was required due to the necessity to monitor and follow up ET production at a single fruit scale. ET is normally synthesised in very low amounts by healthy citrus fruits; however stress conditions such as pathogen attack may induce a substantial increase in the synthesised ET. In the present paper, the comparison between the ET emitted by healthy oranges (Citrus sinensis L. Osbeck) cv Navel and by Phytophthora citrophthora infested Navel orange fruits are reported. The obtained results show a well evident increase in ET emission from the infested fruit with respect to the healthy one, even 24 h after the inoculation with the pathogen; at that time the tissue necrosis was not yet visible, and the fruit was also not yet damaged. The possibility to perform a real time non-destructive detection of ET traces makes the LPAS a powerful tool for monitoring the healthy state of the citrus fruits.

  1. Laser diagnostic technology for early detection of pathogen infestation in orange fruits

    Science.gov (United States)

    Giubileo, Gianfranco; Lai, Antonella; Piccinelli, Delinda; Puiu, Adriana

    2010-11-01

    Due to an increased expectation of food products that respect high quality and safety standards, there is a need for the growth of accurate, fast, objective and non-destructive technologies for quality determination of food and agricultural products. For this purpose, a diagnostic system based on laser photoacoustic spectroscopy (LPAS) was developed at ENEA Frascati Molecular Spectroscopy Laboratory (Italy). In the design of the photoacoustic detector, particular emphasis was placed in attaining a high sensitivity in detecting ethylene (ET) down to sub-parts per billion level (minimum detectable concentration 0.2 ppb). This was required due to the necessity to monitor and follow up ET production at a single fruit scale. ET is normally synthesised in very low amounts by healthy citrus fruits; however stress conditions such as pathogen attack may induce a substantial increase in the synthesised ET. In the present paper, the comparison between the ET emitted by healthy oranges ( Citrus sinensis L. Osbeck) cv Navel and by Phytophthora citrophthora infested Navel orange fruits are reported. The obtained results show a well evident increase in ET emission from the infested fruit with respect to the healthy one, even 24 h after the inoculation with the pathogen; at that time the tissue necrosis was not yet visible, and the fruit was also not yet damaged. The possibility to perform a real time non-destructive detection of ET traces makes the LPAS a powerful tool for monitoring the healthy state of the citrus fruits.

  2. Laser diagnostic technology for early detection of pathogen infestation in orange fruits

    Energy Technology Data Exchange (ETDEWEB)

    Giubileo, Gianfranco, E-mail: gianfranco.giubileo@frascati.enea.i [ENEA Frascati, Via E. Fermi 45, 00044 (Italy); Lai, Antonella; Piccinelli, Delinda [ENEA Frascati, Via E. Fermi 45, 00044 (Italy); Puiu, Adriana [Tor Vergata University of Rome, Faculty of Engineering, Via del Politecnico 1, 00133 Rome (Italy)

    2010-11-11

    Due to an increased expectation of food products that respect high quality and safety standards, there is a need for the growth of accurate, fast, objective and non-destructive technologies for quality determination of food and agricultural products. For this purpose, a diagnostic system based on laser photoacoustic spectroscopy (LPAS) was developed at ENEA Frascati Molecular Spectroscopy Laboratory (Italy). In the design of the photoacoustic detector, particular emphasis was placed in attaining a high sensitivity in detecting ethylene (ET) down to sub-parts per billion level (minimum detectable concentration 0.2 ppb). This was required due to the necessity to monitor and follow up ET production at a single fruit scale. ET is normally synthesised in very low amounts by healthy citrus fruits; however stress conditions such as pathogen attack may induce a substantial increase in the synthesised ET. In the present paper, the comparison between the ET emitted by healthy oranges (Citrus sinensis L. Osbeck) cv Navel and by Phytophthora citrophthora infested Navel orange fruits are reported. The obtained results show a well evident increase in ET emission from the infested fruit with respect to the healthy one, even 24 h after the inoculation with the pathogen; at that time the tissue necrosis was not yet visible, and the fruit was also not yet damaged. The possibility to perform a real time non-destructive detection of ET traces makes the LPAS a powerful tool for monitoring the healthy state of the citrus fruits.

  3. First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

    Energy Technology Data Exchange (ETDEWEB)

    Rosch, R.; Trosseille, C.; Caillaud, T.; Allouche, V.; Bourgade, J. L.; Briat, M.; Brunel, P.; Burillo, M.; Casner, A.; Depierreux, S.; Gontier, D.; Jadaud, J. P.; Le Breton, J. P.; Llavador, P.; Loupias, B.; Miquel, J. L.; Oudot, G.; Perez, S.; Raimbourg, J.; Rousseau, A. [CEA-DAM Ile de France, Bruyères-le-Châtel, 91297 Arpajon Cedex (France); and others

    2016-03-15

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

  4. Experimental Investigation on Admittance-Based Piezoelectric Sensor Diagnostic Process

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyejin; Park, Tongil; Park, Gyuhae [Chonnam National University, Gwangju (Korea, Republic of)

    2015-01-15

    Structural health monitoring (SHM) techniques based on the use of active-sensing piezoelectric (PZT) materials have received considerable attention. The validation of the PZT functionality during SHM operation is critical to successfully implementing a reliable SHM system. In this study, we investigated several parameters that affect the admittance-based sensor diagnostic process. We experimentally identified the temperature dependency of the active-sensor diagnostic process. We found that the admittance-based sensor diagnostic process can differentiate the adhesion conditions of bonding materials that are used to install a PZT on a structure, which is important when designing a sensor diagnostic process for an SHM system.

  5. Development of a two-wavelength IR laser absorption diagnostic for propene and ethylene

    Science.gov (United States)

    Parise, T. C.; Davidson, D. F.; Hanson, R. K.

    2018-05-01

    A two-wavelength infrared laser absorption diagnostic for non-intrusive, simultaneous quantitative measurement of propene and ethylene was developed. To this end, measurements of absorption cross sections of propene and potential interfering species at 10.958 µm were acquired at high-temperatures. When used in conjunction with existing absorption cross-section measurements of ethylene and other species at 10.532 µm, a two-wavelength diagnostic was developed to simultaneously measure propene and ethylene, the two small alkenes found to generally dominate the final decomposition products of many fuel hydrocarbon pyrolysis systems. Measurements of these two species is demonstrated using this two-wavelength diagnostic scheme for propene decomposition between 1360 and 1710 K.

  6. Laser apparatus for surgery and force therapy based on high-power semiconductor and fibre lasers

    International Nuclear Information System (INIS)

    Minaev, V P

    2005-01-01

    High-power semiconductor lasers and diode-pumped lasers are considered whose development qualitatively improved the characteristics of laser apparatus for surgery and force therapy, extended the scope of their applications in clinical practice, and enhanced the efficiency of medical treatment based on the use of these lasers. The characteristics of domestic apparatus are presented and their properties related to the laser emission wavelength used in them are discussed. Examples of modern medical technologies based on these lasers are considered. (invited paper)

  7. Vendor-based laser damage metrology equipment supporting the National Ignition Facility

    International Nuclear Information System (INIS)

    Campbell, J. H; Jennings, R. T.; Kimmons, J. F.; Kozlowski, M. R.; Mouser, R. P.; Schwatz, S.; Stolz, C. J.; Weinzapfel, C. L.

    1998-01-01

    A sizable laser damage metrology effort is required as part of optics production and installation for the 192 beam National Ignition Facility (NIF) laser. The large quantities, high damage thresholds, and large apertures of polished and coated optics necessitates vendor-based metrology equipment to assure component quality during production. This equipment must be optimized to provide the required information as rapidly as possible with limited operator experience. The damage metrology tools include: (1) platinum inclusion damage test systems for laser amplifier slabs, (2) laser conditioning stations for mirrors and polarizers, and (3) mapping and damage testing stations for UV transmissive optics. Each system includes a commercial Nd:YAG laser, a translation stage for the optics, and diagnostics to evaluate damage. The scanning parameters, optical layout, and diagnostics vary with the test fluences required and the damage morphologies expected. This paper describes the technical objectives and milestones involved in fulfilling these metrology requirements

  8. Process observation in fiber laser-based selective laser melting

    Science.gov (United States)

    Thombansen, Ulrich; Gatej, Alexander; Pereira, Milton

    2015-01-01

    The process observation in selective laser melting (SLM) focuses on observing the interaction point where the powder is processed. To provide process relevant information, signals have to be acquired that are resolved in both time and space. Especially in high-power SLM, where more than 1 kW of laser power is used, processing speeds of several meters per second are required for a high-quality processing results. Therefore, an implementation of a suitable process observation system has to acquire a large amount of spatially resolved data at low sampling speeds or it has to restrict the acquisition to a predefined area at a high sampling speed. In any case, it is vitally important to synchronously record the laser beam position and the acquired signal. This is a prerequisite that allows the recorded data become information. Today, most SLM systems employ f-theta lenses to focus the processing laser beam onto the powder bed. This report describes the drawbacks that result for process observation and suggests a variable retro-focus system which solves these issues. The beam quality of fiber lasers delivers the processing laser beam to the powder bed at relevant focus diameters, which is a key prerequisite for this solution to be viable. The optical train we present here couples the processing laser beam and the process observation coaxially, ensuring consistent alignment of interaction zone and observed area. With respect to signal processing, we have developed a solution that synchronously acquires signals from a pyrometer and the position of the laser beam by sampling the data with a field programmable gate array. The relevance of the acquired signals has been validated by the scanning of a sample filament. Experiments with grooved samples show a correlation between different powder thicknesses and the acquired signals at relevant processing parameters. This basic work takes a first step toward self-optimization of the manufacturing process in SLM. It enables the

  9. On scattering diagnostics with periodically pulsed lasers to follow the continuous evolution of time dependent plasma parameters

    International Nuclear Information System (INIS)

    Hellermann, M. von; Hirsch, K.; Doeble, H.F.

    1977-04-01

    The possibilities to use periodically pulsed lasers for plasma scattering diagnostics are discussed. An experiment with succesful application of a periodically pulsed frequency-doubled Nd:YAG laser is described and results are given. Application of the method to monitor continuously, with millisecond time resolution, parameters of Tokamak type plasmas, is considered. (orig.) [de

  10. In situ Laser Diagnostics for Arc-Jet Facilities, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR Phase I effort, Los Gatos Research (LGR) proposes to develop novel instrumentation based on laser absorption spectroscopy techniques for ultrasensitive...

  11. APPLICATION OF LASERS AND LASER-OPTICAL METHODS IN LIFE SCIENCES Spectroscopy of nanoparticles based on Gd14B6Ge2O34 polycrystals and La2O3 — B2O3 glasses, activated by Nd3+ ions, for cancer diagnostics

    Science.gov (United States)

    Popov, A. V.; Ryabova, A. V.; Komova, M. G.; Krut'ko, V. A.; Petrova, O. B.; Loshchenov, V. B.; Voronko, Yu K.

    2011-01-01

    Nanoparticles of gadolinium borate polycrystals and borate glasses, activated by Nd3+ ions, are obtained from macroscopic samples of the corresponding compositions by mechanical grinding and ultrasonic dispersion in water. A spectroscopic study of these nanoparticles in the near-IR region is performed to determine their potential as luminescence biosensors and radiopharmaceutical preparations for cancer diagnostics by radiosensitive methods. A twofold increase in the lifetime of the metastable 4F3/2 state of Nd3+ ions at the transition from submicron polycrystalline particles to nanoparticles is experimentally found. A study of the nanoparticle distribution over organs and tissues of laboratory animals, performed with a 810-nm laser for exciting luminescence and a multichannel fibre spectrometer for measuring fluorescence in the range of 0.8 — 1.2 mm, showed this technique to be sufficiently sensitive to reliably determine the nanoparticle concentration in biological tissues and the dynamics of its change.

  12. Graphene devices based on laser scribing technology

    Science.gov (United States)

    Qiao, Yan-Cong; Wei, Yu-Hong; Pang, Yu; Li, Yu-Xing; Wang, Dan-Yang; Li, Yu-Tao; Deng, Ning-Qin; Wang, Xue-Feng; Zhang, Hai-Nan; Wang, Qian; Yang, Zhen; Tao, Lu-Qi; Tian, He; Yang, Yi; Ren, Tian-Ling

    2018-04-01

    Graphene with excellent electronic, thermal, optical, and mechanical properties has great potential applications. The current devices based on graphene grown by micromechanical exfoliation, chemical vapor deposition (CVD), and thermal decomposition of silicon carbide are still expensive and inefficient. Laser scribing technology, a low-cost and time-efficient method of fabricating graphene, is introduced in this review. The patterning of graphene can be directly performed on solid and flexible substrates. Therefore, many novel devices such as strain sensors, acoustic devices, memory devices based on laser scribing graphene are fabricated. The outlook and challenges of laser scribing technology have also been discussed. Laser scribing may be a potential way of fabricating wearable and integrated graphene systems in the future.

  13. Laser Thomson Scattering, Raman Scattering and laser-absorption diagnostics of high pressure microdischarges

    International Nuclear Information System (INIS)

    Donnelly, Vincent M; Belostotskiy, Sergey G; Economou, Demetre J; Sadeghi, Nader

    2010-01-01

    Laser scattering experiments were performed in high pressure (100s of Torr) parallel-plate, slot-type DC microdischarges operating in argon or nitrogen. Laser Thomson Scattering (LTS) and Rotational Raman Scattering were employed in a novel, backscattering, confocal configuration. LTS allows direct and simultaneous measurement of both electron density (n e ) and electron temperature (T e ). For 50 mA current and over the pressure range of 300 - 700 Torr, LTS yielded T e = 0.9 ± 0.3 eV and n e = (6 ± 3)·10 13 cm -3 , in reasonable agreement with the predictions of a mathematical model. Rotational Raman spectroscopy (RRS) was employed for absolute calibration of the LTS signal. RRS was also applied to measure the 3D gas temperature (T g ) in nitrogen DC microdischarges. In addition, diode laser absorption spectroscopy was employed to measure the density of argon metastables (1s5 in Paschen notations) in argon microdischarges. The gas temperature, extracted from the width of the absorption profile, was compared with T g values obtained by optical emission spectroscopy.

  14. Time-Resolved Spectroscopy Diagnostic of Laser-Induced Optical Breakdown

    Directory of Open Access Journals (Sweden)

    Christian G. Parigger

    2010-01-01

    Full Text Available Transient laser plasma is generated in laser-induced optical breakdown (LIOB. Here we report experiments conducted with 10.6-micron CO2 laser radiation, and with 1.064-micron fundamental, 0.532-micron frequency-doubled, 0.355-micron frequency-tripled Nd:YAG laser radiation. Characterization of laser induced plasma utilizes laser-induced breakdown spectroscopy (LIBS techniques. Atomic hydrogen Balmer series emissions show electron number density of 1017 cm−3 measured approximately 10 μs and 1 μs after optical breakdown for CO2 and Nd:YAG laser radiation, respectively. Recorded molecular recombination emission spectra of CN and C2 Swan bands indicate an equilibrium temperature in excess of 7000 Kelvin, inferred for these diatomic molecules. Reported are also graphite ablation experiments where we use unfocused laser radiation that is favorable for observation of neutral C3 emission due to reduced C3 cation formation. Our analysis is based on computation of diatomic molecular spectra that includes accurate determination of rotational line strengths, or Hönl-London factors.

  15. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Azima, Armin

    2009-07-15

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  16. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    International Nuclear Information System (INIS)

    Azima, Armin

    2009-07-01

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  17. Laser-based agriculture system

    KAUST Repository

    Ooi, Boon S.

    2016-03-31

    A system and method are provided for indoor agriculture using at least one growth chamber illuminated by laser light. In an example embodiment of the agriculture system, a growth chamber is provided having one or more walls defining an interior portion of the growth chamber. The agriculture system may include a removable tray disposed within the interior portion of the growth chamber. The agriculture system also includes a light source, which may be disposed outside the growth chamber. The one or more walls may include at least one aperture. The light source is configured to illuminate at least a part of the interior portion of the growth chamber. In embodiments in which the light source is disposed outside the growth chamber, the light source is configured to transmit the laser light to the interior portion of the growth chamber via the at least one aperture.

  18. Laser-based agriculture system

    KAUST Repository

    Ooi, Boon S.; Wong, Aloysius Tze; Ng, Tien Khee

    2016-01-01

    A system and method are provided for indoor agriculture using at least one growth chamber illuminated by laser light. In an example embodiment of the agriculture system, a growth chamber is provided having one or more walls defining an interior portion of the growth chamber. The agriculture system may include a removable tray disposed within the interior portion of the growth chamber. The agriculture system also includes a light source, which may be disposed outside the growth chamber. The one or more walls may include at least one aperture. The light source is configured to illuminate at least a part of the interior portion of the growth chamber. In embodiments in which the light source is disposed outside the growth chamber, the light source is configured to transmit the laser light to the interior portion of the growth chamber via the at least one aperture.

  19. Laser based spot weld characterization

    Science.gov (United States)

    Jonietz, Florian; Myrach, Philipp; Rethmeier, Michael; Suwala, Hubert; Ziegler, Mathias

    2016-02-01

    Spot welding is one of the most important joining technologies, especially in the automotive industry. Hitherto, the quality of spot welded joints is tested mainly by random destructive tests. A nondestructive testing technique offers the benefit of cost reduction of the testing procedure and optimization of the fabrication process, because every joint could be examined. This would lead to a reduced number of spot welded joints, as redundancies could be avoided. In the procedure described here, the spot welded joint between two zinc-coated steel sheets (HX340LAD+Z100MB or HC340LA+ZE 50/50) is heated optically on one side. Laser radiation and flash light are used as heat sources. The melted zone, the so called "weld nugget" provides the mechanical stability of the connection, but also constitutes a thermal bridge between the sheets. Due to the better thermal contact, the spot welded joint reveals a thermal behavior different from the surrounding material, where the heat transfer between the two sheets is much lower. The difference in the transient thermal behavior is measured with time resolved thermography. Hence, the size of the thermal contact between the two sheets is determined, which is directly correlated to the size of the weld nugget, indicating the quality of the spot weld. The method performs well in transmission with laser radiation and flash light. With laser radiation, it works even in reflection geometry, thus offering the possibility of testing with just one-sided accessibility. By using heating with collimated laser radiation, not only contact-free, but also remote testing is feasible. A further convenience compared to similar thermographic approaches is the applicability on bare steel sheets without any optical coating for emissivity correction. For this purpose, a proper way of emissivity correction was established.

  20. Application of laser diagnostics to sodium-water chemical reaction field

    International Nuclear Information System (INIS)

    Deguchi, Yoshihiro; Tamura, Kenta; Muranaka, Ryota; Kusano, Koji; Kikuchi, Shin; Kurihara, Akikazu

    2013-01-01

    In a sodium-cooled fast reactor (SFR), liquid sodium is used as a heat transfer fluid because of its excellent heat transport capability. On the other hand, it has strong chemical reactivity with water vapor. One of the design basis accidents of the SFR is the water leakage into the liquid sodium flow by a breach of heat transfer tubes in a steam generator. Therefore the study on sodium-water chemical reactions is of paramount importance for safety reasons. This study aims to clarify the sodium-water reaction mechanisms using laser diagnostics. The sodium-water counter-flow reactions were measured using laser diagnostics such as laser induced fluorescence, CARS, Raman scattering and photo-fragmentation. The measurement results show that the sodium-water reaction proceeds mainly by the reaction Na + H 2 O → NaOH + H and the main product is NaOH in this reaction. Its forward and backward reaction rates tend to balance with each other and the whole reaction rate reduces as temperature increases. (author)

  1. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  2. First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, A. L.; Biedron, S. G.; Milton, S. V.; Edelen, J. P.

    2016-12-16

    At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

  3. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  4. Experimental investigation by laser ultrasonics for high speed train axle diagnostics.

    Science.gov (United States)

    Cavuto, A; Martarelli, M; Pandarese, G; Revel, G M; Tomasini, E P

    2015-01-01

    The present paper demonstrates the applicability of a laser-ultrasonic procedure to improve the performances of train axle ultrasonic inspection. The method exploits an air-coupled ultrasonic probe that detects the ultrasonic waves generated by a high-power pulsed laser. As a result, the measurement chain is completely non-contact, from generation to detection, this making it possible to considerably speed up inspection time and make the set-up more flexible. The main advantage of the technique developed is that it works in thermo-elastic regime and it therefore can be considered as a non-destructive method. The laser-ultrasonic procedure investigated has been applied for the inspection of a real high speed train axle provided by the Italian railway company (Trenitalia), on which typical fatigue defects have been expressly created according to standard specifications. A dedicated test bench has been developed so as to rotate the axle with the angle control and to speed up the inspection of the axle surface. The laser-ultrasonic procedure proposed can be automated and is potentially suitable for regular inspection of train axles. The main achievements of the activity described in this paper are: – the study of the effective applicability of laser-ultrasonics for the diagnostic of train hollow axles with variable sections by means of a numerical FE model, – the carrying out of an automated experiment on a real train axle, – the analysis of the sensitivity to experimental parameters, like laser source – receiving probe distance and receiving probe angular position, – the demonstration that the technique is suitable for the detection of surface defects purposely created on the train axle. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Creation of a confined plasma column and diagnostic arrangement for X-ray laser development

    International Nuclear Information System (INIS)

    Voorhees, D.; Keane, C.; Milchberg, H.; Semet, A.; Skinner, C.; Suckewer, S.

    1983-01-01

    We present the experimental arrangement for our soft X-ray laser development program. We describe the various components of the apparatus. These consist of a CO 2 laser, focusing components, solenoidal magnet, targets, pulsed gas mechanisms, diagnostics and data acquisition systems. The experiment utilizes a CO 2 laser with an output energy up to 1 KJ to create a plasma column confined in a solenoidal magnetic field (B less than or equal to 100 KG). Two alternative methods are used to focus the laser energy into the vacuum chamber of the experiment. The first uses a system of two flat mirrors to reflect the 25 cm annular beam to a NaCl lens. The beam then passes through a NaCl window forming the entrance to the vacuum system. A second method consists of a two chamber vacuum system enclosing two flat mirrors and a third spherical mirror. The incident beam passes into the vacuum through one NaCl window eliminating the losses encountered at the NaCl lens of the previously described system. In each case the focused beam interacts with either a solid target, a gas target, or a combination of the two. With gas targets we have used orifices to create a pressure gradient near the point of laser interaction. For some experiments gas is introduced into the system via a fast solenoid valve or piezoactuated puff valve. A calibrated piezoelectronic transducer is utilized to characterize the gas pressure as a function of time and position along the magnetvacuum chamber axis. The resultant pressure profiles enable us to synchronize the firing of the gas valve, magnet and laser to achieve optimum densities in the plasma

  6. A new Thomson Spectrometer for high energy laser-driven beams diagnostic

    International Nuclear Information System (INIS)

    Cirrone, G A P; Tramontana, A; Candiano, G; Cavallaro, S; Cutroneo, M; Cuttone, G; Pisciotta, P; Romano, F; Schillaci, F; Scuderi, V; Torrisi, L; Carpinelli, M; Martinis, C De; Giove, D; Krása, J; Korn, G; Margarone, D; Prokůpek, J; Velyhan, A; Maggiore, M

    2014-01-01

    Thomson Spectrometers (TPs) are widely used for beam diagnostic as they provide simultaneous information on charge over mass ratio, energy and momentum of detected ions. A new TP design has been realized at INFN-LNS within the LILIA (Laser Induced Light Ion Acceleration) and ELIMED (MEDical application at ELI-Beamlines) projects. This paper reports on the construction details of the TP and on its experimental tests performed at PALS laboratory in Prague, with the ASTERIX IV laser system. Reported data are obtained with polyethylene and polyvinyl alcohol solid targets, they have been compared with data obtained from other detectors. Consistency among results confirms the correct functioning of the new TP. The main features, characterizing the design, are a wide acceptance of the deflection sector and a tunability of the, partially overlapping, magnetic and electric fields that allow to resolve ions with energy up to about 40 MeV for protons

  7. Design of laser-aided diagnostics for the negative hydrogen ion source SPIDER

    International Nuclear Information System (INIS)

    Pasqualotto, R

    2012-01-01

    ITER nuclear fusion experiment requires additional heating via neutral beams by means of two injectors, delivering 16.5 MW each, up to one hour. This power level results from the neutralization of negative deuterium ions generated by an RF source and accelerated to 1 MeV. Such specifications have never been simultaneously achieved so far and therefore a test facility is being constructed at Consorzio RFX, to demonstrate the feasibility of a prototype neutral beam injector. The facility will host two experimental devices: SPIDER, a 100 kV negative hydrogen/deuterium RF source, full size prototype of the ITER source, and MITICA, a prototype of the full ITER injector. SPIDER will be devoted to optimize the extracted negative ion current density and its spatial uniformity and to minimize the co-extracted electron current. Negative hydrogen is mainly produced by conversion of hydrogen particles at the cesium coated surface of the plasma grid. The interplay of these two species is fundamental to understand and optimize the source performance. Two laser-aided diagnostics play an important role in measuring the negative hydrogen and cesium density: cavity ring down spectroscopy and laser absorption spectroscopy. Cavity ring down spectroscopy will use the photo-detachment process to measure the absolute line-of-sight integrated negative ion density in the extraction region of the source. Laser absorption spectroscopy will be employed to measure the line integrated neutral cesium density, allowing to study the cesium distribution in the source volume, during both the plasma and the vacuum phases. In this paper, the design of the laser-aided diagnostic systems on SPIDER is presented, supported by a review of results obtained in other operating experiments.

  8. Real-time diagnostics of fast light ion beams accelerated by a sub-nanosecond laser

    Czech Academy of Sciences Publication Activity Database

    Margarone, Daniele; Krása, Josef; Picciotto, A.; Prokůpek, Jan

    2011-01-01

    Roč. 56, č. 2 (2011), s. 137-141 ISSN 0029-5922 R&D Projects: GA ČR(CZ) GAP205/11/1165 EU Projects: European Commission(XE) 212105 - ELI-PP Institutional research plan: CEZ:AV0Z10100523 Keywords : laser-driven acceleration * ion beams * real-time diagnostics Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.389, year: 2011 http://www.nukleonika.pl/www/back/full/vol56_2011/v56n2p137f.pdf

  9. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.

    Science.gov (United States)

    Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-03-01

    To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  11. Verification of a characterization method of the laser-induced selective activation based on industrial lasers

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard; Tang, Peter T.

    2013-01-01

    In this article, laser-induced selective activation (LISA) for subsequent autocatalytic copper plating is performed by several types of industrial scale lasers, including a Nd:YAG laser, a UV laser, a fiber laser, a green laser, and a short pulsed laser. Based on analysis of all the laser......-machined surfaces, normalized bearing area curves and parameters are used to characterize the surface quantitatively. The range of normalized bearing area curve parameters for plate-able surface is suggested. PBT/PET with 40 % glass fiber was used as the substrate material. For all of the studied lasers......, the parameters were varied in a relatively large range, and matrixes of the laser-machined surface were obtained. The topography of those laser-machined surfaces was examined by scanning electronic microscope (SEM). For each sample examined by SEM, there was an identical workpiece plated by for 90 min...

  12. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Directory of Open Access Journals (Sweden)

    Łukasz Ciupiński

    2010-05-01

    Full Text Available Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses. The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in Łódź, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys. Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories.

  13. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Science.gov (United States)

    Ciupiński, Łukasz; Fortuna-Zaleśna, Elżbieta; Garbacz, Halina; Koss, Andrzej; Kurzydłowski, Krzysztof J.; Marczak, Jan; Mróz, Janusz; Onyszczuk, Tomasz; Rycyk, Antoni; Sarzyński, Antoni; Skrzeczanowski, Wojciech; Strzelec, Marek; Zatorska, Anna; Żukowska, Grażyna Z.

    2010-01-01

    Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses). The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in ŁódŸ, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys). Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu) and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories. PMID:22399915

  14. Laser power meters as an X-ray power diagnostic for LCLS-II.

    Science.gov (United States)

    Heimann, Philip; Moeller, Stefan; Carbajo, Sergio; Song, Sanghoon; Dakovski, Georgi; Nordlund, Dennis; Fritz, David

    2018-01-01

    For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. A number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

  15. Laser-induced cavitation based micropump

    NARCIS (Netherlands)

    Dijkink, R.J.; Ohl, C.D.

    2008-01-01

    Lab-on-a-chip devices are in strong demand as versatile and robust pumping techniques. Here, we present a cavitation based technique, which is able to pump a volume of 4000 m3 within 75 s against an estimated pressure head of 3 bar. The single cavitation event is created by focusing a laser pulse in

  16. MBE System for Antimonide Based Semiconductor Lasers

    National Research Council Canada - National Science Library

    Lester, Luke

    1999-01-01

    .... SLR-770 inductively coupled plasma (ICP) processing system. The SLR-770 has been invaluable in the study of plasma etching of AlGaAsSb and GaSb-materials that form the backbone of antimonide-based semiconductor lasers...

  17. A methodology for laser diagnostics in large-bore marine two-stroke diesel engines

    International Nuclear Information System (INIS)

    Hult, J; Mayer, S

    2013-01-01

    Large two-stroke diesel engines for marine propulsion offer several challenges to successful implementation of the laser diagnostic techniques applied extensively in smaller automotive engines. For this purpose a fully operational large-bore engine has been modified to allow flexible optical access, through 24 optical ports with clear diameters of 40 mm. By mounting the entire optical set-up directly to the engine, effects of the vigorous vibrations and thermal drifts on alignment can be minimized. Wide-angle observation and illumination, as well as relatively large aperture detection, is made possible through mounting of optical modules and relays inside optical ports. This allows positioning of the last optical element within 10 mm from the cylinder wall. Finally, the implementation on a multi-cylinder engine allows for flexible and independent operation of the optically accessible cylinder for testing purposes. The performance of the integrated optical engine and imaging system developed is demonstrated through laser Mie scattering imaging of fuel jet structures, from which information on liquid penetration and spray angles can be deduced. Double pulse laser-sheet imaging of native in-cylinder structures is also demonstrated, for the purpose of velocimetry. (paper)

  18. Depth profilometric case studies in caries diagnostics of human teeth using modulated laser radiometry and luminescence

    Science.gov (United States)

    Jeon, Raymond J.; Mandelis, Andreas; Abrams, Stephen H.

    2003-01-01

    Simultaneous measurements from human teeth of photothermal radiometric (PTR) and luminescence (LM) signals induced by an intensity modulated laser have been performed to assess the feasibility of detecting deep lesions and near-surface cracks, to examine the effects of varying enamel thicknesses, the presence of fillings, and stains on the surface of teeth. A commercial dc luminescence monitoring instrument (DIAGNOdent by KaVo) was also used to examine a set of teeth for comparison purposes with PTR and LM. PTR amplitude signals from carious regions and from thin enamel were higher than those from healthy regions and thicker enamel. A crack produces a peak in the PTR amplitude scan, as well as a sudden change in the luminescence amplitude at the corresponding point. At low frequencies (5 Hz), the PTR amplitude showed high sensitivity to a deep (about 2 mm) lesion, while at high frequencies (700 Hz) it was more sensitive to surface cracks. It was concluded that by selecting proper modulation frequencies of the laser, measurements of PTR and LM signals could be used as a dental diagnostic technique with a small, inexpensive, low-power (<30 mW) semiconductor laser as a light source emitting in the optical window range of hard tissue (650-1000 nm).

  19. Influence of laser frequency noise on scanning Fabry-Perot interferometer based laser Doppler velocimetry

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2014-01-01

    n this work, we study the performance of a scanning Fabry-Perot interferometer based laser Doppler velocimeter (sFPILDV) and compare two candidate 1.5 um single-frequency laser sources for the system – a fiber laser (FL) and a semiconductor laser (SL). We describe a straightforward calibration...... procedure for the sFPI-LDV and investigate the effect of different degrees of laser frequency noise between the FL and the SL on the velocimeter’s performance...

  20. LIGHT: Towards a laser-based accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Busold, Simon; Deppert, Oliver; Roth, Markus [Technical University of Darmstadt, Institute for Nuclear Physics, Schlossgartenstrasse 9, 64289 Darmstadt (Germany); Brabetz, Christian [Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany); Burris-Mog, Trevor; Joost, Martin; Cowan, Tom [Helmholtz Center Dresden-Rossendorf, Bautzner Landstrasse 400, 01328 Dresden (Germany); Blazevic, Abel; Bagnoud, Vincent [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Zielbauer, Bernhard [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Helmholtz Institute Jena, Helmholtzweg 4, 07743 Jena (Germany); Kester, Oliver [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany)

    2012-07-01

    Proton acceleration by ultrashort, high intensity laser pulses has been a fast growing field of research during the last decade. The most intensely investigated acceleration mechanism is the TNSA mechanism (Target Normal Sheath Acceleration), providing protons in the multi-MeV-range. For many possible applications, however, the full energy spread and large beam divergence are major draw-backs. Therefore, a pulsed high-field solenoid was used for collimation and energy-selection and is now integrated in a full test stand for a laser-based accelerator at GSI Helmholtz Center, Darmstadt, namely the LIGHT project (Laser Ion Generation, Handling and Transport), which is a collaboration between TU Darmstadt, GSI, HZDR, JWGU Frankfurt and HI Jena. An overview of the new infrastructure, the goals of the LIGHT project, and first experimental results are presented.

  1. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  2. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  3. [Special application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in clinical microbiological diagnostics].

    Science.gov (United States)

    Nagy, Erzsébet; Abrók, Marianna; Bartha, Noémi; Bereczki, László; Juhász, Emese; Kardos, Gábor; Kristóf, Katalin; Miszti, Cecilia; Urbán, Edit

    2014-09-21

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a new possibility for rapid identification of bacteria and fungi revolutionized the clinical microbiological diagnostics. It has an extreme importance in the routine microbiological laboratories, as identification of the pathogenic species rapidly will influence antibiotic selection before the final determination of antibiotic resistance of the isolate. The classical methods for identification of bacteria or fungi, based on biochemical tests, are influenced by many environmental factors. The matrix-assisted laser desorption ionization time-of-flight mass spectrometry is a rapid method which is able to identify a great variety of the isolated bacteria and fungi based on the composition of conserved ribosomal proteins. Recently several other applications of the method have also been investigated such as direct identification of pathogens from the positive blood cultures. There are possibilities to identify bacteria from the urine samples in urinary tract infection or from other sterile body fluids. Using selective enrichment broth Salmonella sp from the stool samples can be identified more rapidly, too. The extended spectrum beta-lactamase or carbapenemase production of the isolated bacteria can be also detected by this method helping the antibiotic selection in some cases. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry based methods are suitable to investigate changes in deoxyribonucleic acid or ribonucleic acid, to carry out rapid antibiotic resistance determination or other proteomic analysis. The aim of this paper is to give an overview about present possibilities of using this technique in the clinical microbiological routine procedures.

  4. Commercialization plan laser-based decoating systems

    International Nuclear Information System (INIS)

    Freiwald, J.; Freiwald, D.A.

    1998-01-01

    F2 Associates Inc. (F2) is a small, high-technology firm focused on developing and commercializing environmentally friendly laser ablation systems for industrial-rate removal of surface coatings from metals, concrete, and delicate substrates such as composites. F2 has a contract with the US Department of Energy Federal Energy Technology Center (FETC) to develop and test a laser-based technology for removing contaminated paint and other contaminants from concrete and metal surfaces. Task 4.1 in Phase 2 of the Statement of Work for this DOE contract requires that F2 ''document its plans for commercializing and marketing the stationary laser ablation system. This document shall include a discussion of prospects for commercial customers and partners and may require periodic update to reflect changing strategy. This document shall be submitted to the DOE for review.'' This report is being prepared and submitted in fulfillment of that requirement. This report describes the laser-based technology for cleaning and coatings removal, the types of laser-based systems that have been developed by F2 based on this technology, and the various markets that are emerging for this technology. F2's commercialization and marketing plans are described, including how F2's organization is structured to meet the needs of technology commercialization, F2's strategy and marketing approach, and the necessary steps to receive certification for removing paint from aircraft and DOE certification for D and D applications. The future use of the equipment built for the DOE contract is also discussed

  5. Laser Safety and Hazard Analysis for the Trailer (B70) Based AURA Laser System

    International Nuclear Information System (INIS)

    AUGUSTONI, ARNOLD L.

    2003-01-01

    A laser safety and hazard analysis was performed for the AURA laser system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1, for ''Safe Use of Lasers'' and the 2000 version of the ANSI Standard Z136.6, for ''Safe Use of Lasers Outdoors''. The trailer based AURA laser system is a mobile platform, which is used to perform laser interaction experiments and tests at various national test sites. The trailer (B70) based AURA laser system is generally operated on the United State Air Force Starfire Optical Range (SOR) at Kirtland Air Force Base (KAFB), New Mexico. The laser is used to perform laser interaction testing inside the laser trailer as well as outside the trailer at target sites located at various distances from the exit telescope. In order to protect personnel, who work inside the Nominal Hazard Zone (NHZ), from hazardous laser emission exposures it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength (wavelength bands) and calculate the appropriate minimum Optical Density (OD min ) of the laser safety eyewear used by authorized personnel and the Nominal Ocular Hazard Distance (NOHD) to protect unauthorized personnel who may have violated the boundaries of the control area and enter into the laser's NHZ

  6. PC based diagnostic system for nitrogen production unit of HWP

    International Nuclear Information System (INIS)

    Lamba, D.S.; Rao, V.C.; Krishnan, S.; Kamaraj, T.; Krishnaswamy, C.

    1992-01-01

    The plant diagnostic system monitors the input data from local processing unit and tries to diagnose the cause of the failure. The system is a rule based application program that can perform tasks itself using fault tree model which displays the logical relationships between critical events and their possible ways occurrence, i.e. hardware failure, process faults and human error etc. Unit 37 Nitrogen Plant is taken as a prototype model for trying the plant diagnostics system. (author). 3 refs., 2 figs

  7. Dual-wavelength differential spectroscopic imaging for diagnostics of laser-induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Motto-Ros, V., E-mail: vincent.motto-ros@univ-lyon1.fr [Universite de Lyon, F-69622, Lyon, Universite Lyon 1, Villeurbanne, CNRS, UMR5579, LASIM (France); Ma, Q.L. [Universite de Lyon, F-69622, Lyon, Universite Lyon 1, Villeurbanne, CNRS, UMR5579, LASIM (France); Gregoire, S. [CRITT Matriaux Alsace, 19 rue de St Junien, 67300 Schiltigheim (France); Lei, W.Q.; Wang, X.C. [Universite de Lyon, F-69622, Lyon, Universite Lyon 1, Villeurbanne, CNRS, UMR5579, LASIM (France); Pelascini, F.; Surma, F. [CRITT Matriaux Alsace, 19 rue de St Junien, 67300 Schiltigheim (France); Detalle, V. [Laboratoire de Recherche des Monuments Historiques, 29 rue de Paris, 77420 Champs-sur-Marne (France); Yu, J. [Universite de Lyon, F-69622, Lyon, Universite Lyon 1, Villeurbanne, CNRS, UMR5579, LASIM (France)

    2012-08-15

    A specific configuration for plasma fast spectroscopic imaging was developed, where a pair of narrowband filters, one fitting an emission line of a species to be studied and the other out of its emission line, allowed double images to be taken for a laser-induced plasma. A dedicated software was developed for the subtraction between the double images. The result represents therefore the monochromatic emission image of the species in the plasma. We have shown in this work that such configuration is especially efficient for the monitoring of a plasma generated under the atmospheric pressure at very short delays after the impact of the laser pulse on the target, when a strong continuum emission is observed. The efficiency of the technique has been particularly demonstrated in the study of laser-induced plasma on a polymer target. Molecular species, such as C{sub 2} and CN, as well as atomic species, such as C and N, were imaged starting from 50 ns after the laser impact. Moreover space segregation of different species, atomic or molecular, inside of the plasma was clearly observed. - Highlights: Black-Right-Pointing-Pointer Imaging to study species with time and space resolution in laser induced plasma. Black-Right-Pointing-Pointer Image display of multiple species is proposed based on RGB color model. Black-Right-Pointing-Pointer Molecular emission (CN and C{sub 2}) is observed at very short delays (50 ns). Black-Right-Pointing-Pointer Segregation of different species inside the plasma is clearly established.

  8. Laser-based coatings removal

    International Nuclear Information System (INIS)

    Freiwald, J.G.; Freiwald, D.

    1995-01-01

    Over the years as building and equipment surfaces became contaminated with low levels of uranium or plutonium dust, coats of paint were applied to stabilize the contaminants in place. Most of the earlier paint used was lead-based paint. More recently, various non-lead-based paints, such as two-part epoxy, are used. For D ampersand D (decontamination and decommissioning), it is desirable to remove the paints or other coatings rather than having to tear down and dispose of the entire building

  9. Spectroscopical plasma diagnostics for the procedure optimization in laser-beam high-speed cutting; Spektroskopische Plasmadiagnostik zur Verfahrensoptimierung beim Laserstrahl-Hochgeschwindigkeitsschneiden

    Energy Technology Data Exchange (ETDEWEB)

    Nate, M.

    2001-07-01

    In the present thesis the laser-induced plasma typical for the high- speed cutting process was studied in the region of the interaction zone. For this especially the absorption properties of the plasma for the incident laser radiation and their correlation with the maximally reachable cutting speeds. For this with methods of the spectroscopic plasma diagnostics the influence of different process parameters on the quantities characterizing the plasma, electron density and temperature, was determined. On the base of these values in the framework of an equilibrium model the densities of all particles contained in the plasma were determined. With these values the plasma absorption coefficient was subsequently calculated and the laser radiation absorbed in the plasma estimated.

  10. High Efficiency Mask Based Laser Materials Processing with TEA-CO2 - and Excimer Laser

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1997-01-01

    In general, mask based laser materials processing techniques suffer from a very low energy efficiency. We have developed a simple device called an energy enhancer, which is capable of increasing the energy efficiency of typical mask based laser materials processing systems. A short review of the ...... line marking with TEA-CO2 laser of high speed canning lines. The second one is manufactured for marking or microdrilling with excimer laser....

  11. Diagnostics of a stationary MPD-type plasma jet with a HCN laser interferometer

    International Nuclear Information System (INIS)

    Graser, W.; Hoffmann, P.

    1975-01-01

    A HCN laser interferometer of the Ashby-Jephcott type operating at a wavelength of 337 μm was used to measure spatially resolved electron densities in a stationary MPD-type plasma jet with non-LTE behavior. Experiments were performed with and without superimposed magnetic fields up to 0.1 T at the exit of the plasma accelerator. Electron densities were obtained within the limits of 5times10 12 and 10 15 cm -3 with an accuracy better than 10%. Within the axially symmetric expanding plasma of about 15-cm average diameter and 50-cm length the radial resolving power came to less than 1 cm. So this technique has proved to be suitable to fill a gap in the diagnostics of stationary magnetized plasmas in the mean range of electron densities. (auth)

  12. Transverse phase space diagnostics for ionization injection in laser plasma acceleration using permanent magnetic quadrupoles

    Science.gov (United States)

    Li, F.; Nie, Z.; Wu, Y. P.; Guo, B.; Zhang, X. H.; Huang, S.; Zhang, J.; Cheng, Z.; Ma, Y.; Fang, Y.; Zhang, C. J.; Wan, Y.; Xu, X. L.; Hua, J. F.; Pai, C. H.; Lu, W.; Mori, W. B.

    2018-04-01

    We report the transverse phase space diagnostics for electron beams generated through ionization injection in a laser-plasma accelerator. Single-shot measurements of both ultimate emittance and Twiss parameters are achieved by means of permanent magnetic quadrupole. Beams with emittance of μm rad level are obtained in a typical ionization injection scheme, and the dependence on nitrogen concentration and charge density is studied experimentally and confirmed by simulations. A key feature of the transverse phase space, matched beams with Twiss parameter α T ≃ 0, is identified according to the measurement. Numerical simulations that are in qualitative agreement with the experimental results reveal that a sufficient phase mixing induced by an overlong injection length leads to the matched phase space distribution.

  13. Prediction of temperature-insensitive molecular absorption lines in laser-assisted combustion diagnostics

    International Nuclear Information System (INIS)

    Walewski, Joachim W.; Elmqvist, Anders

    2005-01-01

    In laser-assisted combustion diagnostics it is a recurring task to predict molecular transitions whose signal strength depends only weakly on variations in temperature. The signal strength is proportional to the Boltzmann fraction of the level probed and the amplitude of the absorption line profile. In the past investigations have been presented in which this task was attack by detailed numerical calculations of the temperature dependence of pertinent physical properties of the molecule. Another widely applied approach relies on an analytical formula for the Boltzmann fraction of hetero-nuclear diatomic molecules and the neglect of line shape effects. The analytical approach experiences a continuing popularity in laser-assisted combustion diagnostics, which is why we compared both approaches with each other. The objective of this comparison was to assess the accuracy of the analytical approach and to reveal its potential pitfalls. Our comparison revealed that the analytical approach suffers from mediocre accuracy, which makes it unfit for practical applications. One cause is the neglect of higher lying vibrational levels, which show a non-negligible population for typical flame temperatures. Another reason is the neglect of fine structure splitting in molecules with non-zero orbit angular momentum in the ground state. Another reason for the observed inaccuracy is the neglect of line shape effects quenching, which were found to have a significant effect on the temperature sensitivity of a line. Because of its insufficient accuracy due to both oversimplified models of the molecular energy levels and the neglect of line shape effects and quenching we discourage from applying the analytical approach and recommend the use of detailed numerical approaches that are free of the above limitations

  14. LASER CLADDING ON ALUMINIUM BASE ALLOYS

    OpenAIRE

    Pilloz , M.; Pelletier , J.; Vannes , A.; Bignonnet , A.

    1991-01-01

    laser cladding is often performed on iron or titanium base alloys. In the present work, this method is employed on aluminum alloys ; nickel or silicon are added by powder injection. Addition of silicon leads to sound surface layers, but with moderated properties, while the presence of nickel induces the formation of hard intermetallic compounds and then to an attractive hardening phenomena ; however a recovery treatment has to be carried out, in order to eliminate porosity in the near surface...

  15. Problems in the development of autonomous mobile laser systems based on a cw chemical DF laser

    International Nuclear Information System (INIS)

    Aleksandrov, B P; Bashkin, A S; Beznozdrev, V N; Parfen'ev, M V; Pirogov, N A; Semenov, S N

    2003-01-01

    The problems involved in designing autonomous mobile laser systems based on high-power cw chemical DF lasers, whose mass and size parameters would make it possible to install them on various vehicles, are discussed. The need for mobility of such lasers necessitates special attention to be paid to the quest for ways and means of reducing the mass and size of the main laser systems. The optimisation of the parameters of such lasers is studied for various methods of scaling their systems. A complex approach to analysis of the optical scheme of the laser system is developed. (special issue devoted to the 80th anniversary of academician n g basov's birth)

  16. Optical diagnostics of CO2 laser-fusion targets using backscattered light

    International Nuclear Information System (INIS)

    Casperson, D.E.

    1981-01-01

    With the f/2.4 focusing optics on one of the eight Helios CO 2 laser beam lines, direct backscattered light from a variety of glass microballoon targets has been observed. The quantities that have been measured include: (1) the total backscattered energy; (2) relative amplitudes of the backscattered fundamental and low harmonics (n = 1, 2, 3) of the 10.6 μm incident light; (3) the 3/2 harmonic emission from a double pulse backscatter experiment; (4) the temporally resolved 10.6 μm light using a fast pyroelectric detector and a Los Alamos 5-GHz oscilloscope; and (5) the time-integrated spectrally resolved fundamental using a 3/4 meter spectrometer and a high resolution pyroelectric detector array (resolution approx. 40 A at 10.6 μm). The suitability of these diagnostics for evaluating the CO 2 laser plasma in terms of stimulated scattering processes, plasma density gradients, velocity of the critical surface, etc., is discussed

  17. UV Laser Diagnostics of the 1-MA Z-pinch Plasmas

    International Nuclear Information System (INIS)

    Altemara, S. D.; Ivanov, V. V.; Astanovitskiy, A. L.; Haboub, A.

    2009-01-01

    The 532 nm laser diagnostic set at the Zebra generator shows the details of the ablation and stagnation phases in cylindrical, planar, and star-like wire arrays but it cannot show the structure of the stagnated z-pinch and the implosion in small diameter loads, 1-3 mm in diameter. The absorption increment and the refraction angle of the 532 nm laser, when passing through the plasma, are too great to obtain quality images. An ultraviolet probing beam at the wavelength of 266 nm was developed to study small-diameter loads and to investigate the structure of the 1-MA z-pinch. The UV radiation has a much smaller absorption increment and refraction angles in plasmas than the 532 nm light and allows for better imaging of the z-pinch plasmas. Estimates showed that UV probing would be able to probe the high-density z-pinch plasma in experiments on the Zebra generator, and the early results of UV probing on the Zebra generator have shown promise.

  18. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Dornmair, Irene

    2017-05-15

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  19. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    International Nuclear Information System (INIS)

    Dornmair, Irene

    2017-05-01

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  20. Advances in nucleic acid-based diagnostics of bacterial infections

    DEFF Research Database (Denmark)

    Barken, Kim Bundvig; Haagensen, Janus Anders Juul; Tolker-Nielsen, Tim

    2007-01-01

    Methods for rapid detection of infectious bacteria and antimicrobial-resistant pathogens have evolved significantly over the last decade. Many of the new procedures are nucleic acid-based and replace conventional diagnostic methods like culturing which is time consuming especially with fastidious...... of these pathogens is important to isolate patients and prevent further spreading of the diseases. Newly developed diagnostic procedures are superior with respect to turnaround time, sensitivity and specificity. Methods like multiplex real time PCR and different array-based technologies offer the possibility...

  1. The diagnostic capability of laser induced fluorescence in the characterization of excised breast tissues

    Science.gov (United States)

    Galmed, A. H.; Elshemey, Wael M.

    2017-08-01

    Differentiating between normal, benign and malignant excised breast tissues is one of the major worldwide challenges that need a quantitative, fast and reliable technique in order to avoid personal errors in diagnosis. Laser induced fluorescence (LIF) is a promising technique that has been applied for the characterization of biological tissues including breast tissue. Unfortunately, only few studies have adopted a quantitative approach that can be directly applied for breast tissue characterization. This work provides a quantitative means for such characterization via introduction of several LIF characterization parameters and determining the diagnostic accuracy of each parameter in the differentiation between normal, benign and malignant excised breast tissues. Extensive analysis on 41 lyophilized breast samples using scatter diagrams, cut-off values, diagnostic indices and receiver operating characteristic (ROC) curves, shows that some spectral parameters (peak height and area under the peak) are superior for characterization of normal, benign and malignant breast tissues with high sensitivity (up to 0.91), specificity (up to 0.91) and accuracy ranking (highly accurate).

  2. Enhanced diagnostic of skin conditions by polarized laser speckles: phantom studies and computer modeling

    Science.gov (United States)

    Tchvialeva, Lioudmila; Lee, Tim K.; Markhvida, Igor; Zeng, Haishan; Doronin, Alexander; Meglinski, Igor

    2014-03-01

    The incidence of the skin melanoma, the most commonly fatal form of skin cancer, is increasing faster than any other potentially preventable cancer. Clinical practice is currently hampered by the lack of the ability to rapidly screen the functional and morphological properties of tissues. In our previous study we show that the quantification of scattered laser light polarization provides a useful metrics for diagnostics of the malignant melanoma. In this study we exploit whether the image speckle could improve skin cancer diagnostic in comparison with the previously used free-space speckle. The study includes skin phantom measurements and computer modeling. To characterize the depolarization of light we measure the spatial distribution of speckle patterns and analyse their depolarization ratio taken into account radial symmetry. We examine the dependences of depolarization ratio vs. roughness for phantoms which optical properties are of the order of skin lesions. We demonstrate that the variation in bulk optical properties initiates the assessable changes in the depolarization ratio. We show that image speckle differentiates phantoms significantly better than free-space speckle. The results of experimental measurements are compared with the results of Monte Carlo simulation.

  3. A two photon absorption laser induced fluorescence diagnostic for fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Magee, R. M.; Galante, M. E.; McCarren, D.; Scime, E. E. [Physics Department, West Virginia University, Morgantown, West Virginia 26506 (United States); Boivin, R. L.; Brooks, N. H.; Groebner, R. J.; Hill, D. N. [General Atomics, San Diego, California 92121 (United States); Porter, G. D. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    The quality of plasma produced in a magnetic confinement fusion device is influenced to a large extent by the neutral gas surrounding the plasma. The plasma is fueled by the ionization of neutrals, and charge exchange interactions between edge neutrals and plasma ions are a sink of energy and momentum. Here we describe a diagnostic capable of measuring the spatial distribution of neutral gas in a magnetically confined fusion plasma. A high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup -1}) laser is injected into a hydrogen plasma to excite the Lyman {beta} transition via the simultaneous absorption of two 205 nm photons. The absorption rate, determined by measurement of subsequent Balmer {alpha} emission, is proportional to the number of particles with a given velocity. Calibration is performed in situ by filling the chamber to a known pressure of neutral krypton and exciting a transition close in wavelength to that used in hydrogen. We present details of the calibration procedure, including a technique for identifying saturation broadening, measurements of the neutral density profile in a hydrogen helicon plasma, and discuss the application of the diagnostic to plasmas in the DIII-D tokamak.

  4. A two photon absorption laser induced fluorescence diagnostic for fusion plasmas.

    Science.gov (United States)

    Magee, R M; Galante, M E; McCarren, D; Scime, E E; Boivin, R L; Brooks, N H; Groebner, R J; Hill, D N; Porter, G D

    2012-10-01

    The quality of plasma produced in a magnetic confinement fusion device is influenced to a large extent by the neutral gas surrounding the plasma. The plasma is fueled by the ionization of neutrals, and charge exchange interactions between edge neutrals and plasma ions are a sink of energy and momentum. Here we describe a diagnostic capable of measuring the spatial distribution of neutral gas in a magnetically confined fusion plasma. A high intensity (5 MW/cm(2)), narrow bandwidth (0.1 cm(-1)) laser is injected into a hydrogen plasma to excite the Lyman β transition via the simultaneous absorption of two 205 nm photons. The absorption rate, determined by measurement of subsequent Balmer α emission, is proportional to the number of particles with a given velocity. Calibration is performed in situ by filling the chamber to a known pressure of neutral krypton and exciting a transition close in wavelength to that used in hydrogen. We present details of the calibration procedure, including a technique for identifying saturation broadening, measurements of the neutral density profile in a hydrogen helicon plasma, and discuss the application of the diagnostic to plasmas in the DIII-D tokamak.

  5. Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

    Science.gov (United States)

    Grinstead, Jay; Wilder, Michael C.; Porter, Barry; Brown, Jeff; Yeung, Dickson; Battazzo, Steve; Brubaker, Tim

    2016-01-01

    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnsons arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

  6. Cognitive diagnostic assessment based on knowledge structure

    Directory of Open Access Journals (Sweden)

    Huang Sue-Fen

    2018-01-01

    Full Text Available The purpose of this study is to provide an integrated method of fuzzy theory basis for individualized concept structure analysis. In order to insight the misconception of learning basic mathematics and progress teaching. This method integrates Fuzzy Logic Model of Perception (FLMP and Interpretive Structural Modelling (ISM. The combined algorithm could analyze individualized concepts structure based on the comparisons with concept structure of expert. In this paper, some well-known knowledge structure assessment methods will be discussed. For item connection, Bart et al ordering theory and Takeya’s item relational structure provided ordering coefficient to construct item relationships and hierarchies. For concepts or skills connection, Warfield’s ISM and Lin et al Concept Advanced Interpretive Structural Modelling (CAISM provided to construct graphic relationship among elements and display the individualized concept hierarchy structure by numeric and picture. Samples contain 427 which come from Min-Hwei Junior College. Subjects were analyzed by CAISM. It shows the traditional assessment is not the only criteria; it must be combined with other assessment tools. The result shows that CAISM gives meaningful learning and lacks of learners.

  7. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Foley, E. L.; Levinton, F. M. [Nova Photonics, Inc., Princeton, New Jersey 08540 (United States)

    2013-04-15

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  8. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    Science.gov (United States)

    Foley, E. L.; Levinton, F. M.

    2013-04-01

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  9. Betatron emission as a diagnostic for injection and acceleration mechanisms in laser plasma accelerators

    International Nuclear Information System (INIS)

    Corde, S; Thaury, C; Phuoc, K Ta; Lifschitz, A; Lambert, G; Lundh, O; Brijesh, P; Sebban, S; Rousse, A; Faure, J; Malka, V; Arantchuk, L

    2012-01-01

    Betatron x-ray emission in laser plasma accelerators is a promising compact source that may be an alternative to conventional x-ray sources, based on large scale machines. In addition to its potential as a source, precise measurements of betatron emission can reveal crucial information about relativistic laser–plasma interaction. We show that the emission length and the position of the x-ray emission can be obtained by placing an aperture mask close to the source, and by measuring the beam profile of the betatron x-ray radiation far from the aperture mask. The position of the x-ray emission gives information on plasma wave breaking and hence on the laser non-linear propagation. Moreover, the measurement of the longitudinal extension helps one to determine whether the acceleration is limited by pump depletion or dephasing effects. In the case of multiple injections, it is used to retrieve unambiguously the position in the plasma of each injection. This technique is also used to study how, in a capillary discharge, the variations of the delay between the discharge and the laser pulse affect the interaction. The study reveals that, for a delay appropriate for laser guiding, the x-ray emission only occurs in the second half of the capillary: no electrons are injected and accelerated in the first half. (paper)

  10. Analysis of relaxing laser-induced plasmas by absorption spectroscopy: Toward a new quantitative diagnostic technique

    International Nuclear Information System (INIS)

    Ribiere, M.; Cheron, B.G.

    2010-01-01

    Broad-band near UV absorption spectroscopy was used to analyze atmospheric laser-induced plasmas formed on metallic and refractory targets. When the common emission spectroscopy only provides the density of the radiating atomic excited states, the technique reported in this paper is able to achieve high spatial resolution in the measurement of absolute number densities in expanding laser-induced plasmas. The reliability and the versatility of this technique, which is based on the comparison between results of the numerical integration of the radiative transfer equation and experimental spectra, were tested on different targets. The evolutions in time and space of the absolute population of the plasma species originating from metallic alloys (Al-Mg and Cu-Ni) and refractory materials (C/SiC) were achieved over large time scales. Owing to its accuracy, this absorption technique (that we call 'LIPAS' for Laser Induced Plasma Absorption Spectroscopy) should bring a new and enhanced support to the validation of collisional-radiative models attempting to provide reliable evolutions of laser-induced plasmas.

  11. Rapid development of paper-based fluidic diagnostic devices

    CSIR Research Space (South Africa)

    Smith, S

    2014-11-01

    Full Text Available We present a method for rapid and low-cost development of microfluidic diagnostic devices using paper-based techniques. Specifically, the implementation of fluidic flow paths and electronics on paper are demonstrated, with the goal of producing...

  12. MRI-based diagnostic imaging of the intratemporal facial nerve

    International Nuclear Information System (INIS)

    Kress, B.; Baehren, W.

    2001-01-01

    Detailed imaging of the five sections of the full intratemporal course of the facial nerve can be achieved by MRI and using thin tomographic section techniques and surface coils. Contrast media are required for tomographic imaging of pathological processes. Established methods are available for diagnostic evaluation of cerebellopontine angle tumors and chronic Bell's palsy, as well as hemifacial spasms. A method still under discussion is MRI for diagnostic evaluation of Bell's palsy in the presence of fractures of the petrous bone, when blood volumes in the petrous bone make evaluation even more difficult. MRI-based diagnostic evaluation of the idiopatic facial paralysis currently is subject to change. Its usual application cannot be recommended for routine evaluation at present. However, a quantitative analysis of contrast medium uptake of the nerve may be an approach to improve the prognostic value of MRI in acute phases of Bell's palsy. (orig./CB) [de

  13. Energy enhancer for mask based laser materials processing

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1996-01-01

    A device capable of drastically improving the energy efficiency of present mask based laser materials processing systems is presented. Good accordance between experiments and simulations for a TEA-CO2 laser system designed for laser marking has been demonstrated. The energy efficiency may...... be improved with a factor of 2 - 4 for typical mask transmittances between 10 - 40%....

  14. Beam diagnostics based on virtual instrument technology for HLS

    International Nuclear Information System (INIS)

    Sun Baogen; Lu Ping; Wang Xiaohui; Wang Baoyun; Wang Junhua; Gu Liming; Fang Jia; Ma Tianji

    2009-01-01

    The paper introduce the beam diagnostics system using virtual instrument technology for Hefei Light Source (HLS), which includes a GPIB bus-based DCCT measurement system to measure the beam DC current and beam life, a VXIbus-based closed orbit measurement system to measure the beam position, a PCIbus-based beam profile measurement system to measure the beam profile and emittance, a GPIB-LAN based bunch length system using photoelectric method, and a Ethernet-based photon beam position measurement system. The software is programmed by LabVIEW, which reduces much developing work. (authors)

  15. Recent results in mirror based high power laser cutting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Nielsen, Jakob Skov; Elvang, Mads

    2004-01-01

    In this paper, recent results in high power laser cutting, obtained in reseach and development projects are presented. Two types of mirror based focussing systems for laser cutting have been developed and applied in laser cutting studies on CO2-lasers up to 12 kW. In shipyard environment cutting...... speed increase relative to state-of-the-art cutting of over 100 % has been achieved....

  16. Optical methods for diagnostics and feedback control in laser-induced regeneration of spine disc and joint cartilages

    Science.gov (United States)

    Sobol, Emil; Sviridov, Alexander; Omeltchenko, Alexander; Baum, Olga; Baskov, Andrey; Borchshenko, Igor; Golubev, Vladimir; Baskov, Vladimir

    2011-03-01

    In 1999 we have introduced a new approach for treatment of spine diseases based on the mechanical effect of nondestructive laser radiation on the nucleus pulposus of the intervertebral disc. Laser reconstruction of spine discs (LRD) involves puncture of the disc and non-destructive laser irradiation of the nucleus pulposus to activate reparative processes in the disc tissues. In vivo animal study has shown that LRD allows activate the growth of hyaline type cartilage in laser affected zone. The paper considers physical processes and mechanisms of laser regeneration, presents results of investigations aimed to optimize laser settings and to develop feedback control system for laser reparation in cartilages of spine and joints. The results of laser reconstruction of intervertebral discs for 510 patients have shown substantial relief of back pain for 90% of patients. Laser technology has been experimentally tested for reparation of traumatic and degenerative diseases in joint cartilage of 20 minipigs. It is shown that laser regeneration of cartilage allows feeling large (more than 5 mm) defects which usually never repair on one's own. Optical techniques have been used to promote safety and efficacy of the laser procedures.

  17. Diagnostic capability of scanning laser polarimetry with and without enhanced corneal compensation and optical coherence tomography.

    Science.gov (United States)

    Benítez-del-Castillo, Javier; Martinez, Antonio; Regi, Teresa

    2011-01-01

    To compare the abilities of the current commercially available versions of scanning laser polarimetry (SLP) and optical coherence tomography (OCT), SLP-variable corneal compensation (VCC), SLP-enhanced corneal compensation (ECC), and high-definition (HD) OCT, in discriminating between healthy eyes and those with early-to-moderate glaucomatous visual field loss. Healthy volunteers and patients with glaucoma who met the eligibility criteria were consecutively enrolled in this prospective, cross-sectional, observational study. Subjects underwent complete eye examination, automated perimetry, SLP-ECC, SLP-VCC, and HD-OCT. Scanning laser polarimetry parameters were recalculated in 90-degree segments (quadrants) in the calculation circle to be compared. Areas under the receiver operating characteristic curve (AUROCs) were calculated for every parameter in order to compare the ability of each imaging modality to differentiate between normal and glaucomatous eyes. Fifty-five normal volunteers (mean age 59.1 years) and 33 patients with glaucoma (mean age 63.8 years) were enrolled. Average visual field mean deviation was -6.69 dB (95% confidence interval -8.07 to -5.31) in the glaucoma group. The largest AUROCs were associated with nerve fiber indicator (0.880 and 0.888) for the SLP-VCC and SLP-ECC, respectively, and with the average thickness in the HD-OCT (0.897). The best performing indices for the SLP-VCC, SLP-ECC, and HD OCT gave similar AUROCs, showing moderate diagnostic accuracy in patients with early to moderate glaucoma. Further studies are needed to evaluate the ability of these technologies to discriminate between normal and glaucomatous eyes.

  18. Intelligent model-based diagnostics for vehicle health management

    Science.gov (United States)

    Luo, Jianhui; Tu, Fang; Azam, Mohammad S.; Pattipati, Krishna R.; Willett, Peter K.; Qiao, Liu; Kawamoto, Masayuki

    2003-08-01

    The recent advances in sensor technology, remote communication and computational capabilities, and standardized hardware/software interfaces are creating a dramatic shift in the way the health of vehicles is monitored and managed. These advances facilitate remote monitoring, diagnosis and condition-based maintenance of automotive systems. With the increased sophistication of electronic control systems in vehicles, there is a concomitant increased difficulty in the identification of the malfunction phenomena. Consequently, the current rule-based diagnostic systems are difficult to develop, validate and maintain. New intelligent model-based diagnostic methodologies that exploit the advances in sensor, telecommunications, computing and software technologies are needed. In this paper, we will investigate hybrid model-based techniques that seamlessly employ quantitative (analytical) models and graph-based dependency models for intelligent diagnosis. Automotive engineers have found quantitative simulation (e.g. MATLAB/SIMULINK) to be a vital tool in the development of advanced control systems. The hybrid method exploits this capability to improve the diagnostic system's accuracy and consistency, utilizes existing validated knowledge on rule-based methods, enables remote diagnosis, and responds to the challenges of increased system complexity. The solution is generic and has the potential for application in a wide range of systems.

  19. Development of electromagnetic induction diagnostics technology for condition based maintenance

    International Nuclear Information System (INIS)

    Mawatari, Shingo; Oeda, Kaoru; Yatogi, Hideo; Fukuchi, Taira; Ueno, Tadashi

    2008-01-01

    In ROKKASHO Reprocessing Plant (below, called 'RRP'), we have applied Condition Based Maintenance to rotating equipment with vibration diagnostics technology. However, a few rotating equipment are difficult to diagnose definitely, because have structural problems which exercise vibrational noise to peripheral and be impossible to install vibratory sensor. Electromagnetic induction diagnostics technology which measure magnetic fields to eddy current which is induced to rotary through static magnetic field, diagnose deterioration behavior such as abrasion and crack. As a result, it has possibilities to clear above problems. Therefore, we started our basic researches with this technology for Condition Based Maintenance. In this paper, it introduces basic data about 'Non-seal pump' that have installed in RRP. As a result, this technology is a possibility that be able to detect Condition Based Maintenance. (author)

  20. Laser-induced breakdown spectroscopy (LIBS), part I: review of basic diagnostics and plasma-particle interactions: still-challenging issues within the analytical plasma community.

    Science.gov (United States)

    Hahn, David W; Omenetto, Nicoló

    2010-12-01

    Laser-induced breakdown spectroscopy (LIBS) has become a very popular analytical method in the last decade in view of some of its unique features such as applicability to any type of sample, practically no sample preparation, remote sensing capability, and speed of analysis. The technique has a remarkably wide applicability in many fields, and the number of applications is still growing. From an analytical point of view, the quantitative aspects of LIBS may be considered its Achilles' heel, first due to the complex nature of the laser-sample interaction processes, which depend upon both the laser characteristics and the sample material properties, and second due to the plasma-particle interaction processes, which are space and time dependent. Together, these may cause undesirable matrix effects. Ways of alleviating these problems rely upon the description of the plasma excitation-ionization processes through the use of classical equilibrium relations and therefore on the assumption that the laser-induced plasma is in local thermodynamic equilibrium (LTE). Even in this case, the transient nature of the plasma and its spatial inhomogeneity need to be considered and overcome in order to justify the theoretical assumptions made. This first article focuses on the basic diagnostics aspects and presents a review of the past and recent LIBS literature pertinent to this topic. Previous research on non-laser-based plasma literature, and the resulting knowledge, is also emphasized. The aim is, on one hand, to make the readers aware of such knowledge and on the other hand to trigger the interest of the LIBS community, as well as the larger analytical plasma community, in attempting some diagnostic approaches that have not yet been fully exploited in LIBS.

  1. 2005 Laser Diagnostics in Combustion Gordon Conference July 31-August 5, 2005

    Energy Technology Data Exchange (ETDEWEB)

    Mark G. Allen

    2005-08-01

    The Gordon Research Conference (GRC) on LASER DIAGNOSTICS IN COMBUSTION was held at Mount Holyoke College from 7/31/2005 thru 8/5/2005. The Conference was well-attended with 121 participants (attendees list attached). The attendees represented the spectrum of endeavor in this field coming from academia, industry, and government laboratories, both U.S. and foreign scientists, senior researchers, young investigators, and students. In designing the formal speakers program, emphasis was placed on current unpublished research and discussion of the future target areas in this field. There was a conscious effort to stimulate lively discussion about the key issues in the field today. Time for formal presentations was limited in the interest of group discussions. In order that more scientists could communicate their most recent results, poster presentation time was scheduled. Attached is a copy of the formal schedule and speaker program and the poster program. In addition to these formal interactions, ''free time'' was scheduled to allow informal discussions. Such discussions are fostering new collaborations and joint efforts in the field. I want to personally thank you for your support of this Conference. As you know, in the interest of promoting the presentation of unpublished and frontier-breaking research, Gordon Research Conferences does not permit publication of meeting proceedings. If you wish any further details, please feel free to contact me.

  2. Intelligent DNA-based molecular diagnostics using linked genetic markers

    Energy Technology Data Exchange (ETDEWEB)

    Pathak, D.K.; Perlin, M.W.; Hoffman, E.P.

    1994-12-31

    This paper describes a knowledge-based system for molecular diagnostics, and its application to fully automated diagnosis of X-linked genetic disorders. Molecular diagnostic information is used in clinical practice for determining genetic risks, such as carrier determination and prenatal diagnosis. Initially, blood samples are obtained from related individuals, and PCR amplification is performed. Linkage-based molecular diagnosis then entails three data analysis steps. First, for every individual, the alleles (i.e., DNA composition) are determined at specified chromosomal locations. Second, the flow of genetic material among the individuals is established. Third, the probability that a given individual is either a carrier of the disease or affected by the disease is determined. The current practice is to perform each of these three steps manually, which is costly, time consuming, labor-intensive, and error-prone. As such, the knowledge-intensive data analysis and interpretation supersede the actual experimentation effort as the major bottleneck in molecular diagnostics. By examining the human problem solving for the task, we have designed and implemented a prototype knowledge-based system capable of fully automating linkage-based molecular diagnostics in X-linked genetic disorders, including Duchenne Muscular Dystrophy (DMD). Our system uses knowledge-based interpretation of gel electrophoresis images to determine individual DNA marker labels, a constraint satisfaction search for consistent genetic flow among individuals, and a blackboard-style problem solver for risk assessment. We describe the system`s successful diagnosis of DMD carrier and affected individuals from raw clinical data.

  3. Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, nathaniel R.; Baggott, Renee S.; Singh, Upendra N.; Kavaya, Michael J.

    2004-01-01

    Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

  4. Observation of a rainbow of visible colors in a near infrared cascaded Raman fiber laser and its novel application as a diagnostic tool for length resolved spectral analysis

    Science.gov (United States)

    Aparanji, Santosh; Balaswamy, V.; Arun, S.; Supradeepa, V. R.

    2018-02-01

    In this work, we report and analyse the surprising observation of a rainbow of visible colors, spanning 390nm to 620nm, in silica-based, Near Infrared, continuous-wave, cascaded Raman fiber lasers. The cascaded Raman laser is pumped at 1117nm at around 200W and at full power we obtain 100 W at 1480nm. With increasing pump power at 1117nm, the fiber constituting the Raman laser glows in various hues along its length. From spectroscopic analysis of the emitted visible light, it was identified to be harmonic and sum-frequency components of various locally propagating wavelength components. In addition to third harmonic components, surprisingly, even 2nd harmonic components were observed. Despite being a continuous-wave laser, we expect the phase-matching occurring between the core-propagating NIR light with the cladding-propagating visible wavelengths and the intensity fluctuations characteristic of Raman lasers to have played a major role in generation of visible light. In addition, this surprising generation of visible light provides us a powerful non-contact method to deduce the spectrum of light propagating in the fiber. Using static images of the fiber captured by a standard visible camera such as a DSLR, we demonstrate novel, image-processing based techniques to deduce the wavelength component propagating in the fiber at any given spatial location. This provides a powerful diagnostic tool for both length and power resolved spectral analysis in Raman fiber lasers. This helps accurate prediction of the optimal length of fiber required for complete and efficient conversion to a given Stokes wavelength.

  5. Laser-Based Additive Manufacturing of Zirconium

    Directory of Open Access Journals (Sweden)

    Himanshu Sahasrabudhe

    2018-03-01

    Full Text Available Additive manufacturing of zirconium is attempted using commercial Laser Engineered Net Shaping (LENSTM technique. A LENSTM-based approach towards processing coatings and bulk parts of zirconium, a reactive metal, aims to minimize the inconvenience of traditional metallurgical practices of handling and processing zirconium-based parts that are particularly suited to small volumes and one-of-a-kind parts. This is a single-step manufacturing approach for obtaining near net shape fabrication of components. In the current research, Zr metal powder was processed in the form of coating on Ti6Al4V alloy substrate. Scanning electron microscopy (SEM and energy dispersive spectroscopy (EDS as well as phase analysis via X-ray diffraction (XRD were studied on these coatings. In addition to coatings, bulk parts were also fabricated using LENS™ from Zr metal powders, and measured part accuracy.

  6. 2011 Laser Diagnostics in Combustion Gordon Research Conference, (August 14-19, 2011, Waterville Valley Resort, Waterville Valley, NH)

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Settersten

    2011-08-19

    The vast majority of the world's energy needs are met by combustion of fossil fuels. Optimum utilization of limited resources and control of emissions of pollutants and greenhouse gases demand sustained improvement of combustion technology. This task can be satisfied only by detailed knowledge of the underlying physical and chemical processes. Non-intrusive laser diagnostics continuously contribute to our growing understanding of these complex and coupled multi-scale processes. The GRC on Laser Diagnostics in Combustion focuses on the most recent scientific advances and brings together scientists and engineers working at the leading edge of combustion research. Major tasks of the community are developing and applying methods for precise and accurate measurements of fluid motion and temperatures; chemical compositions; multi-phase phenomena appearing near walls, in spray and sooting combustion; improving sensitivities, precision, spatial resolution and tracking transients in their spatio-temporal development. The properties and behaviour of novel laser sources, detectors, optical systems that lead to new diagnostic capabilities are also part of the conference program.

  7. Diagnostic markers of urothelial cancer based on DNA methylation analysis

    International Nuclear Information System (INIS)

    Chihara, Yoshitomo; Hirao, Yoshihiko; Kanai, Yae; Fujimoto, Hiroyuki; Sugano, Kokichi; Kawashima, Kiyotaka; Liang, Gangning; Jones, Peter A; Fujimoto, Kiyohide; Kuniyasu, Hiroki

    2013-01-01

    Early detection and risk assessment are crucial for treating urothelial cancer (UC), which is characterized by a high recurrence rate, and necessitates frequent and invasive monitoring. We aimed to establish diagnostic markers for UC based on DNA methylation. In this multi-center study, three independent sample sets were prepared. First, DNA methylation levels at CpG loci were measured in the training sets (tumor samples from 91 UC patients, corresponding normal-appearing tissue from these patients, and 12 normal tissues from age-matched bladder cancer-free patients) using the Illumina Golden Gate methylation assay to identify differentially methylated loci. Next, these methylated loci were validated by quantitative DNA methylation by pyrosequencing, using another cohort of tissue samples (Tissue validation set). Lastly, methylation of these markers was analyzed in the independent urine samples (Urine validation set). ROC analysis was performed to evaluate the diagnostic accuracy of these 12 selected markers. Of the 1303 CpG sites, 158 were hyper ethylated and 356 were hypo ethylated in tumor tissues compared to normal tissues. In the panel analysis, 12 loci showed remarkable alterations between tumor and normal samples, with 94.3% sensitivity and 97.8% specificity. Similarly, corresponding normal tissue could be distinguished from normal tissues with 76.0% sensitivity and 100% specificity. Furthermore, the diagnostic accuracy for UC of these markers determined in urine samples was high, with 100% sensitivity and 100% specificity. Based on these preliminary findings, diagnostic markers based on differential DNA methylation at specific loci can be useful for non-invasive and reliable detection of UC and epigenetic field defect

  8. Mueller-matrix of laser-induced autofluorescence of polycrystalline films of dried peritoneal fluid in diagnostics of endometriosis

    Science.gov (United States)

    Ushenko, Yuriy A.; Koval, Galina D.; Ushenko, Alexander G.; Dubolazov, Olexander V.; Ushenko, Vladimir A.; Novakovskaia, Olga Yu.

    2016-07-01

    This research presents investigation results of the diagnostic efficiency of an azimuthally stable Mueller-matrix method of analysis of laser autofluorescence of polycrystalline films of dried uterine cavity peritoneal fluid. A model of the generalized optical anisotropy of films of dried peritoneal fluid is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase (linear and circular birefringence) and amplitude (linear and circular dichroism) anisotropies is taken into consideration. The interconnections between the azimuthally stable Mueller-matrix elements characterizing laser autofluorescence and different mechanisms of optical anisotropy are determined. The statistical analysis of coordinate distributions of such Mueller-matrix rotation invariants is proposed. Thereupon the quantitative criteria (statistic moments of the first to the fourth order) of differentiation of polycrystalline films of dried peritoneal fluid, group 1 (healthy donors) and group 2 (uterus endometriosis patients), are determined.

  9. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    Science.gov (United States)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  10. Key techniques for space-based solar pumped semiconductor lasers

    Science.gov (United States)

    He, Yang; Xiong, Sheng-jun; Liu, Xiao-long; Han, Wei-hua

    2014-12-01

    In space, the absence of atmospheric turbulence, absorption, dispersion and aerosol factors on laser transmission. Therefore, space-based laser has important values in satellite communication, satellite attitude controlling, space debris clearing, and long distance energy transmission, etc. On the other hand, solar energy is a kind of clean and renewable resources, the average intensity of solar irradiation on the earth is 1353W/m2, and it is even higher in space. Therefore, the space-based solar pumped lasers has attracted much research in recent years, most research focuses on solar pumped solid state lasers and solar pumped fiber lasers. The two lasing principle is based on stimulated emission of the rare earth ions such as Nd, Yb, Cr. The rare earth ions absorb light only in narrow bands. This leads to inefficient absorption of the broad-band solar spectrum, and increases the system heating load, which make the system solar to laser power conversion efficiency very low. As a solar pumped semiconductor lasers could absorb all photons with energy greater than the bandgap. Thus, solar pumped semiconductor lasers could have considerably higher efficiencies than other solar pumped lasers. Besides, solar pumped semiconductor lasers has smaller volume chip, simpler structure and better heat dissipation, it can be mounted on a small satellite platform, can compose satellite array, which can greatly improve the output power of the system, and have flexible character. This paper summarizes the research progress of space-based solar pumped semiconductor lasers, analyses of the key technologies based on several application areas, including the processing of semiconductor chip, the design of small and efficient solar condenser, and the cooling system of lasers, etc. We conclude that the solar pumped vertical cavity surface-emitting semiconductor lasers will have a wide application prospects in the space.

  11. Portable Diode Laser Diagnostic System for Collaborative Research on Air-Breathing Combustion

    National Research Council Canada - National Science Library

    Hanson, Ronald

    2003-01-01

    This equipment grant focused on four areas: (1) portable diode laser sensors with new fiber-coupled diode lasers and the support equipment to provide higher power with extended wavelength tuning range and speed; (2...

  12. Proteinuria: The diagnostic strategy based on urine proteins differentiation

    Directory of Open Access Journals (Sweden)

    Stojimirović Biljana B.

    2004-01-01

    Full Text Available Basal glomerular membrane represents mechanical and electrical barrier for passing of the plasma proteins. Mechanical barrier is composed of cylindrical pores and filtration fissure, and negative layer charge in exterior and interior side of basal glomerular membrane, made of heparan sulphate and sialoglicoproteine, provides certain electrical barrier. Diagnostic strategy based on different serum and urine proteins enables the differentiation of various types of proteinuria. Depending on etiology of proteinuria it can be prerenal, renal and postrenal. By analyzing albumin, armicroglobulin, immunoglobulin G and armacroglobulin, together with total protein in urine, it is possible to detect and differentiate causes of prerenal, renal (glomerular, tubular, glomerulo-tubular and postrenal proteinuria. The adequate and early differentiation of proteinuria type is of an immense diagnostic and therapeutic importance.

  13. Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnstico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharg de Neon

    Energy Technology Data Exchange (ETDEWEB)

    Tafalla, D.; Cal, E. de la; Tabares, F. L.

    1994-07-01

    A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, the density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength, bandwidth and energy profile and Rayleigh scattering in N2 was used for the optical system calibration. An absolute density of Cr atoms of n {approx} 5x10 cm was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal us. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma. (Author) 19 refs.

  14. A 3 ps synchronised multi-frame photographic diagnostic for target experiments with the iodine laser

    International Nuclear Information System (INIS)

    Maaswinkel, A.G.M.; Sigel, R.; Baumhacker, H.; Brederlow, G.

    1982-10-01

    A laser system is described with which we obtain a sequence of 6 pictures (interferograms or shadowgrams) of the plasma produced by the iodine laser on solid targets. The system consists of a synchronously pumped dye laser amplified in dye cells pumped by an excimer laser. It delivers a pulse with an energy of 400 μJ and a length of 3 ps at a wavelength of 580 nm that is highly synchronous with the iodine pulse. (orig.)

  15. 77 FR 14838 - General Electric-Hitachi Global Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-13

    ... Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment Facility, Wilmington, North Carolina... a license to General Electric-Hitachi Global Laser Enrichment LLC (GLE or the applicant) to authorize construction of a laser-based uranium enrichment facility and possession and use of byproduct...

  16. Laser based micro forming and assembly.

    Energy Technology Data Exchange (ETDEWEB)

    MacCallum, Danny O' Neill; Wong, Chung-Nin Channy; Knorovsky, Gerald Albert; Steyskal, Michele D.; Lehecka, Tom (Pennsylvania State University, Freeport, PA); Scherzinger, William Mark; Palmer, Jeremy Andrew

    2006-11-01

    It has been shown that thermal energy imparted to a metallic substrate by laser heating induces a transient temperature gradient through the thickness of the sample. In favorable conditions of laser fluence and absorptivity, the resulting inhomogeneous thermal strain leads to a measurable permanent deflection. This project established parameters for laser micro forming of thin materials that are relevant to MESA generation weapon system components and confirmed methods for producing micrometer displacements with repeatable bend direction and magnitude. Precise micro forming vectors were realized through computational finite element analysis (FEA) of laser-induced transient heating that indicated the optimal combination of laser heat input relative to the material being heated and its thermal mass. Precise laser micro forming was demonstrated in two practical manufacturing operations of importance to the DOE complex: micrometer gap adjustments of precious metal alloy contacts and forming of meso scale cones.

  17. Planar Laser-Based QEPAS Trace Gas Sensor

    Directory of Open Access Journals (Sweden)

    Yufei Ma

    2016-06-01

    Full Text Available A novel quartz enhanced photoacoustic spectroscopy (QEPAS trace gas detection scheme is reported in this paper. A cylindrical lens was employed for near-infrared laser focusing. The laser beam was shaped as a planar line laser between the gap of the quartz tuning fork (QTF prongs. Compared with a spherical lens-based QEPAS sensor, the cylindrical lens-based QEPAS sensor has the advantages of easier laser beam alignment and a reduction of stringent stability requirements. Therefore, the reported approach is useful in long-term and continuous sensor operation.

  18. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  19. Glycosylation-Based Serum Biomarkers for Cancer Diagnostics and Prognostics.

    Science.gov (United States)

    Kirwan, Alan; Utratna, Marta; O'Dwyer, Michael E; Joshi, Lokesh; Kilcoyne, Michelle

    2015-01-01

    Cancer is the second most common cause of death in developed countries with approximately 14 million newly diagnosed individuals and over 6 million cancer-related deaths in 2012. Many cancers are discovered at a more advanced stage but better survival rates are correlated with earlier detection. Current clinically approved cancer biomarkers are most effective when applied to patients with widespread cancer. Single biomarkers with satisfactory sensitivity and specificity have not been identified for the most common cancers and some biomarkers are ineffective for the detection of early stage cancers. Thus, novel biomarkers with better diagnostic and prognostic performance are required. Aberrant protein glycosylation is well known hallmark of cancer and represents a promising source of potential biomarkers. Glycoproteins enter circulation from tissues or blood cells through active secretion or leakage and patient serum is an attractive option as a source for biomarkers from a clinical and diagnostic perspective. A plethora of technical approaches have been developed to address the challenges of glycosylation structure detection and determination. This review summarises currently utilised glycoprotein biomarkers and novel glycosylation-based biomarkers from the serum glycoproteome under investigation as cancer diagnostics and for monitoring and prognostics and includes details of recent high throughput and other emerging glycoanalytical techniques.

  20. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  1. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    International Nuclear Information System (INIS)

    Pak, S.; Kim, Y.; Park, K.Y.; Lee, K.D.; Cheon, M.S.; Lee, H.G.

    2010-01-01

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  2. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    Energy Technology Data Exchange (ETDEWEB)

    Pak, S. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)], E-mail: paksunil@nfri.re.kr; Kim, Y.; Park, K.Y.; Lee, K.D. [Institute for Advanced Engineering, 633-2, Goan-ri, Baegam-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do (Korea, Republic of); Cheon, M.S.; Lee, H.G. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)

    2010-04-15

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  3. High-power pulsed lasers

    International Nuclear Information System (INIS)

    Holzrichter, J.F.

    1980-01-01

    The ideas that led to the successful construction and operation of large multibeam fusion lasers at the Lawrence Livermore Laboratory are reviewed. These lasers are based on the use of Nd:glass laser materials. However, most of the concepts are applicable to any laser being designed for fusion experimentation. This report is a summary of lectures given by the author at the 20th Scottish University Summer School in Physics, on Laser Plasma Interaction. This report includes basic concepts of the laser plasma system, a discussion of lasers that are useful for short-pulse, high-power operation, laser design constraints, optical diagnostics, and system organization

  4. Pulsed Laser Cladding of Ni Based Powder

    Science.gov (United States)

    Pascu, A.; Stanciu, E. M.; Croitoru, C.; Roata, I. C.; Tierean, M. H.

    2017-06-01

    The aim of this paper is to optimize the operational parameters and quality of one step Metco Inconel 718 atomized powder laser cladded tracks, deposited on AISI 316 stainless steel substrate by means of a 1064 nm high power pulsed laser, together with a Precitec cladding head manipulated by a CLOOS 7 axes robot. The optimization of parameters and cladding quality has been assessed through Taguchi interaction matrix and graphical output. The study demonstrates that very good cladded layers with low dilution and increased mechanical proprieties could be fabricated using low laser energy density by involving a pulsed laser.

  5. GaN-based blue laser diodes

    Energy Technology Data Exchange (ETDEWEB)

    Miyajima, Takao; Yanashima, Katsunori; Funato, Kenji; Asatsuma, Tsunenori; Kobayashi, Toshimasa [CT Development Centre, CNC, Sony Corporation, Atsugi, Kanagawa (Japan); Tojyo, Tsuyoshi; Asano, Takeharu; Kijima, Satoru; Hino, Tomonori; Takeya, Motonobu; Uchida, Shiro; Ikeda, Masao [Sony Shiroishi Semiconductor Inc., Shiroishi, Miyagi (Japan); Tomiya, Shigetaka [Environment and Analyhsis Technology Department, Sony Corporation, Hodogaya, Yokohama (Japan)

    2001-08-13

    We report our recent progress on GaN-based high-power laser diodes (LDs), which will be applied as a light source in high-density optical storage systems. We have developed raised-pressure metal-organic chemical vapour deposition (RP-MOCVD), which can reduce the threading-dislocation density in the GaN layer to several times 10{sup 8} cm{sup -2}, and demonstrated continuous-wave (cw) operation of GaN-based LD grown by RP-MOCVD. Furthermore, we found that the epitaxial lateral overgrowth (ELO) technique is useful for further reducing threading-dislocation density to 10{sup 6} cm{sup -2} and reducing the roughness of the cleaved facet. By using this growth technique and optimizing device parameters, the lifetime of LDs was improved to more than 1000 hours under 30 mW cw operation at 60 deg. C. Our results proved that reducing both threading-dislocation density and consumption power is a valid approach to realizing a practical GaN-based LD. On the other hand, the practical GaN-based LD was obtained when threading-dislocation density in ELO-GaN was only reduced to 10{sup 6} cm{sup -2}, which is a relatively small reduction as compared with threading-dislocation density in GaAs- and InP-based LDs. We believe that the multiplication of non-radiative centres is very slow in GaN-based LDs, possibly due to the innate character of the GaN-based semiconductor itself. (author)

  6. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Zangeneh, H.R.; Zamanipour, Z.; Davoud-Abadi, Gh.R.

    2008-01-01

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler

  7. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of)], E-mail: parvin@aut.ac.ir; Jaleh, B. [Physics Department, Bu-Ali Sina University, Postal Code 65174, Hamedan (Iran, Islamic Republic of); Zangeneh, H.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Zamanipour, Z. [Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of); Davoud-Abadi, Gh.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of)

    2008-08-15

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler.

  8. Optical Sideband Generation: a Longitudinal Electron Beam Diagnostic Beyond the Laser Bandwidth Resolution Limit

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence Berkeley National Laboratory; Tilborg, J. van; Matlis, N. H.; Plateau, G. R.; Leemans, W. P.

    2010-06-01

    Electro-optic sampling (EOS) is widely used as a technique to measure THz-domain electric field pulses such asthe self-fields of femtosecond electron beams. We present an EOS-based approach for single-shot spectral measurement that excels in simplicity (compatible with fiber integration) and bandwidth coverage (overcomes the laser bandwidth limitation), allowing few-fs electron beams or single-cycle THz pulses to be characterized with conventional picosecond probes. It is shown that the EOS-induced optical sidebands on the narrow-bandwidth optical probe are spectrally-shifted replicas of the THz pulse. An experimental demonstration on a 0-3 THz source is presented.

  9. En Route: next-generation laser-plasma-based electron accelerators

    International Nuclear Information System (INIS)

    Hidding, Bernhard

    2008-05-01

    same time they increase the acceptance of laser-plasma-accelerator technology for future international accelerator projects. A second main focus of this thesis is on electron acceleration with (overdense) solids, again using the JETI laser pulses. New diagnostics based on Image Plate stacks and Monte Carlo-Simulations have been developed, and amongst other things, relativistic electron beams have been found, which propagate (nearly) parallel to the target surface. Using PIC-Simulations, it was demonstrated that these electrons can be accelerated in the transient laser interference fields created by incident and reflected laser pulse, leading to fields as high as several 10 TV/m. These electrons are not monoenergetic, but can have sub-fs-pulse durations, rendering them useful for injection in future multi-staged laser-plasma accelerators, for instance. (orig.)

  10. Simulation based analysis of laser beam brazing

    Science.gov (United States)

    Dobler, Michael; Wiethop, Philipp; Schmid, Daniel; Schmidt, Michael

    2016-03-01

    Laser beam brazing is a well-established joining technology in car body manufacturing with main applications in the joining of divided tailgates and the joining of roof and side panels. A key advantage of laser brazed joints is the seam's visual quality which satisfies highest requirements. However, the laser beam brazing process is very complex and process dynamics are only partially understood. In order to gain deeper knowledge of the laser beam brazing process, to determine optimal process parameters and to test process variants, a transient three-dimensional simulation model of laser beam brazing is developed. This model takes into account energy input, heat transfer as well as fluid and wetting dynamics that lead to the formation of the brazing seam. A validation of the simulation model is performed by metallographic analysis and thermocouple measurements for different parameter sets of the brazing process. These results show that the multi-physical simulation model not only can be used to gain insight into the laser brazing process but also offers the possibility of process optimization in industrial applications. The model's capabilities in determining optimal process parameters are exemplarily shown for the laser power. Small deviations in the energy input can affect the brazing results significantly. Therefore, the simulation model is used to analyze the effect of the lateral laser beam position on the energy input and the resulting brazing seam.

  11. A Ribeiroia spp. (Class: Trematoda) - Specific PCR-based diagnostic

    Science.gov (United States)

    Reinitz, David M.; Yoshino, T.P.; Cole, Rebecca A.

    2007-01-01

    Increased reporting of amphibian malformations in North America has been noted with concern in light of reports that amphibian numbers and species are declining worldwide. Ribeiroia ondatrae has been shown to cause a variety of types of malformations in amphibians. However, little is known about the prevalence of R. ondatrae in North America. To aid in conducting field studies of Ribeiroia spp., we have developed a polymerase chain reaction (PCR)-based diagnostic. Herein, we describe the development of an accurate, rapid, simple, and cost-effective diagnostic for detection of Ribeiroia spp. infection in snails (Planorbella trivolvis). Candidate oligonucleotide primers for PCR were designed via DNA sequence analyses of multiple ribosomal internal transcribed spacer-2 regions from Ribeiroia spp. and Echinostoma spp. Comparison of consensus sequences determined from both genera identified areas of sequence potentially unique to Ribeiroia spp. The PCR reliably produced a diagnostic 290-base pair (bp) product in the presence of a wide concentration range of snail or frog DNA. Sensitivity was examined with DNA extracted from single R. ondatrae cercaria. The single-tube PCR could routinely detect less than 1 cercariae equivalent, because DNA isolated from a single cercaria could be diluted at least 1:50 and still yield a positive result via gel electrophoresis. An even more sensitive nested PCR also was developed that routinely detected 100 fg of the 290-bp fragment. The assay did not detect furcocercous cercariae of certain Schistosomatidae, Echinostoma sp., or Sphaeridiotrema globulus nor adults of Clinostomum sp. or Cyathocotyle bushiensis. Field testing of 137 P. trivolvis identified 3 positives with no overt environmental cross-reactivity, and results concurred with microscopic examinations in all cases. ?? American Society of Parasitologists 2007.

  12. Electronics and Algorithms for HOM Based Beam Diagnostics

    Science.gov (United States)

    Frisch, Josef; Baboi, Nicoleta; Eddy, Nathan; Nagaitsev, Sergei; Hensler, Olaf; McCormick, Douglas; May, Justin; Molloy, Stephen; Napoly, Olivier; Paparella, Rita; Petrosyan, Lyudvig; Ross, Marc; Simon, Claire; Smith, Tonee

    2006-11-01

    The signals from the Higher Order Mode (HOM) ports on superconducting cavities can be used as beam position monitors and to do survey structure alignment. A HOM-based diagnostic system has been installed to instrument both couplers on each of the 40 cryogenic accelerating structures in the DESY TTF2 Linac. The electronics uses a single stage down conversion from the 1.7 GHz HOM spectral line to a 20MHz IF which has been digitized. The electronics is based on low cost surface mount components suitable for large scale production. The analysis of the HOM data is based on Singular Value Decomposition. The response of the OM modes is calibrated using conventional BPMs.

  13. Laser wakefield accelerator based light sources: potential applications and requirements

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). NIF and Photon Sciences; Thomas, A. G. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Sciences; Mangles, S. P.D. [Imperial College, London (United Kingdom). Blackett Lab.; Banerjee, S. [Univ. of Nebraska, Lincoln, NE (United States); Corde, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Flacco, A. [ENSTA, CNRS, Ecole Polytechnique, Palaiseau (France); Litos, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Neely, D. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Viera, J. [Univ. of Lisbon (Portugal). GoLP-Inst. de Plasmas e Fusao Nuclear-Lab. Associado; Najmudin, Z. [Imperial College, London (United Kingdom). Blackett Lab.; Bingham, R. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Joshi, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering; Katsouleas, T. [Duke Univ., Durham, NC (United States). Platt School of Engineering

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  14. Development of a high power HCN waveguide laser for plasma diagnostic

    International Nuclear Information System (INIS)

    Deng Zhongchao; Zhou Yan; Tang Yiwu; Yi Jiang; Gao Bingyi; Tian Chongli

    2007-06-01

    Both design and development of a high power cw HCN waveguide laser is described for multichannel FIR laser interferometer on the HL-2A divertor tokamak. The geometry parameters of stracture of the HCN laser are calculated according to scaling laws for cw 337 μm HCN waveguide laser offered by P. Belland et al. The designed value of output power of the laser that is more than 400 mW with discharge length of 5.6 m and 6.3 cm inner diameter of tube have been chosen in case of external loss of the cavity of 2%. At the same time, in order to get a laser system of stable output both of configuration and operating condition is discussed. In developed laser a hot LaB 6 cathode is employed to en- sure a stable discharge, the cavity mirrors are spaced using four invar rod of φ25 mm in diameter and an structure of adjusting machine for axially movable flat mirror in cavity has been also designed, and that it can be taken down many times without badly destroying alignment of the cavity etc.. A suit of pipes sys- tem of cw HCN laser is schemed out so that some experiments of operating parameter optimization can be done. The results of primary test of operating waveguide HCN laser are briefly showed. (authors)

  15. Capabilities of laser technology for manufacturing diagnostic peptide matrices with maximal density

    Energy Technology Data Exchange (ETDEWEB)

    Baum, O I; Shcherbakov, E M; Sobol' , E N [Institute on Laser and Information Technologies of the Russian Academy of Sciencies, Troitsk, Moscow (Russian Federation); Nesterov-Müller, A [Karlsruhe Institute of Technology, Institute of Microstructure Technology (Germany)

    2016-02-28

    The process of manufacturing a matrix-gel biochip is modelled by means of laser fused deposition of a layer of polymer microparticles, containing a sensitive peptide element, onto a glass substrate. The limits of acceptable ranges and the optimal values of laser parameters, at which the melting of the polymer coating occurs without damaging the sensitive elements of the biochip, are theoretically determined. The results of the experiments on laser fused deposition of a layer of microparticles having the size 3 – 4 μm confirm the conservation of the functions of the biological complexes at optimal irradiation regimes. The parameters of the laser impact affecting the possible minimal separation between the zones of laser fused deposition are investigated. The essential role of heat conductivity and thermoplasticity of the polymer in increasing the size of the melted droplet is demonstrated. Using the laser radiation with the wavelength 532 nm focused into a spot with the diameter 6 μm (the laser pulse duration being 10 ms) the laser fused deposition density of 110000 spots per 1 cm{sup 2} is achieved. The maximal estimated density of laser fused deposition for the studied system amounts to 250000 spots per 1 cm{sup 2}. (biophotonics)

  16. A Stark-tuned, far-infrared laser for high frequency plasma diagnostics

    International Nuclear Information System (INIS)

    Mansfield, D.K.; Vocaturo, M.; Guttadora, L.; Rockmore, M.; Micai, K.; Krug, P.A.

    1992-03-01

    A Stark-tuned optically pumped far-infrared methanol laser operating at 119 micrometers has been built. The laser is designed to operate at high power while exhibiting a well-separated Stark doublet. At a pump power of 65 Watts and electric field of 1 kV/cm the laser has delivered over 100 mW c.w. while exhibiting a frequency splitting of 34 MHz. These parameters indicate that this laser would be suitable for use in the present generation of modulated interferometers on large thermonuclear plasma devices. The achieved modulation frequency is more than an order of magnitude higher than could be achieved using standard techniques

  17. Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics.

    Science.gov (United States)

    Tang, Longhua; Li, Jinghong

    2017-07-28

    Colorimetric detection of target analytes with high specificity and sensitivity is of fundamental importance to clinical and personalized point-of-care diagnostics. Because of their extraordinary optical properties, plasmonic nanomaterials have been introduced into colorimetric sensing systems, which provide significantly improved sensitivity in various biosensing applications. Here we review the recent progress on these plasmonic nanoparticles-based colorimetric nanosensors for ultrasensitive molecular diagnostics. According to their different colorimetric signal generation mechanisms, these plasmonic nanosensors are classified into two categories: (1) interparticle distance-dependent colorimetric assay based on target-induced forming cross-linking assembly/aggregate of plasmonic nanoparticles; and (2) size/morphology-dependent colorimetric assay by target-controlled growth/etching of the plasmonic nanoparticles. The sensing fundamentals and cutting-edge applications will be provided for each of them, particularly focusing on signal generation and/or amplification mechanisms that realize ultrasensitive molecular detection. Finally, we also discuss the challenge and give our future perspective in this emerging field.

  18. Symptom based diagnostic system using artificial neural networks

    International Nuclear Information System (INIS)

    Santosh; Vinod, Gopika; Saraf, R.K.

    2003-01-01

    Nuclear power plant experiences a number of transients during its operations. In case of such an undesired plant condition generally known as an initiating event, the operator has to carry out diagnostic and corrective actions. The operator's response may be too late to mitigate or minimize the negative consequences in such scenarios. The objective of this work is to develop an operator support system based on artificial neural networks that will assist the operator to identify the initiating events at the earliest stages of their developments. A symptom based diagnostic system has been developed to investigate the initiating events. Neutral networks are utilized for carrying out the event identification by continuously monitoring process parameters. Whenever an event is detected, the system will display the necessary operator actions along with the initiating event. The system will also show the graphical trend of process parameters that are relevant to the event. This paper describes the features of the software that is used to monitor the reactor. (author)

  19. Power System Transient Diagnostics Based on Novel Traveling Wave Detection

    Science.gov (United States)

    Hamidi, Reza Jalilzadeh

    Modern electrical power systems demand novel diagnostic approaches to enhancing the system resiliency by improving the state-of-the-art algorithms. The proliferation of high-voltage optical transducers and high time-resolution measurements provide opportunities to develop novel diagnostic methods of very fast transients in power systems. At the same time, emerging complex configuration, such as multi-terminal hybrid transmission systems, limits the applications of the traditional diagnostic methods, especially in fault location and health monitoring. The impedance-based fault-location methods are inefficient for cross-bounded cables, which are widely used for connection of offshore wind farms to the main grid. Thus, this dissertation first presents a novel traveling wave-based fault-location method for hybrid multi-terminal transmission systems. The proposed method utilizes time-synchronized high-sampling voltage measurements. The traveling wave arrival times (ATs) are detected by observation of the squares of wavelet transformation coefficients. Using the ATs, an over-determined set of linear equations are developed for noise reduction, and consequently, the faulty segment is determined based on the characteristics of the provided equation set. Then, the fault location is estimated. The accuracy and capabilities of the proposed fault location method are evaluated and also compared to the existing traveling-wave-based method for a wide range of fault parameters. In order to improve power systems stability, auto-reclosing (AR), single-phase auto-reclosing (SPAR), and adaptive single-phase auto-reclosing (ASPAR) methods have been developed with the final objectives of distinguishing between the transient and permanent faults to clear the transient faults without de-energization of the solid phases. However, the features of the electrical arcs (transient faults) are severely influenced by a number of random parameters, including the convection of the air and plasma

  20. Potential for GPC-based laser direct writing

    DEFF Research Database (Denmark)

    Bañas, Andrew; Glückstad, Jesper

    2016-01-01

    lasers for such applications by using phase modulation as opposed to amplitude truncating masks. Here, we explore GPC’s potential for increasing the yield of micropscopic 3D printing also known as direct laser writing. Many light based additive manufacturing techniques, adopt a point scanning approach...

  1. Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Oudini, N. [Laboratoire des plasmas de décharges, Centre de Développement des Technologies Avancées, Cité du 20 Aout BP 17 Baba Hassen, 16081 Algiers (Algeria); Taccogna, F. [Istituto di Metodologie Inorganiche e dei Plasmi, CNR, via Amendola 122/D, 70126 Bari (Italy); Bendib, A. [Laboratoire d' Electronique Quantique, Faculté de Physique, USTHB, El Alia BP 32, Bab Ezzouar 16111, Algiers (Algeria); Aanesland, A. [Laboratoire de Physique des Plasmas (CNRS, Ecole Polytechnique, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud), École Polytechnique, 91128 Palaiseau Cedex (France)

    2014-06-15

    Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

  2. Methodology for assessing laser-based equipment

    Science.gov (United States)

    Pelegrina-Bonilla, Gabriel; Hermsdorf, Jörg; Thombansen, Ulrich; Abels, Peter; Kaierle, Stefan; Neumann, Jörg

    2017-10-01

    Methodologies for the assessment of technology's maturity are widely used in industry and research. Probably the best known are technology readiness levels (TRLs), initially pioneered by the National Aeronautics and Space Administration (NASA). At the beginning, only descriptively defined TRLs existed, but over time, automated assessment techniques in the form of questionnaires emerged in order to determine TRLs. Originally TRLs targeted equipment for space applications, but the demands on industrial relevant equipment are partly different in terms of, for example, overall costs, product quantities, or the presence of competitors. Therefore, we present a commonly valid assessment methodology with the aim of assessing laser-based equipment for industrial use, in general. The assessment is carried out with the help of a questionnaire, which allows for a user-friendly and easy accessible way to monitor the progress from the lab-proven state to the application-ready product throughout the complete development period. The assessment result is presented in a multidimensional metric in order to reveal the current specific strengths and weaknesses of the equipment development process, which can be used to direct the remaining development process of the equipment in the right direction.

  3. Entropy-Based Clutter Rejection for Intrawall Diagnostics

    Directory of Open Access Journals (Sweden)

    Raffaele Solimene

    2012-01-01

    Full Text Available The intrawall diagnostic problem of detecting localized inhomogeneities possibly present within the wall is addressed. As well known, clutter arising from masonry structure can impair detection of embedded scatterers due to high amplitude reflections that wall front face introduces. Moreover, internal multiple reflections also can make it difficult ground penetrating radar images (radargramms interpretation. To counteract these drawbacks, a clutter rejection method, properly tailored on the wall features, is mandatory. To this end, here we employ a windowing strategy based on entropy measures of temporal traces “similarity.” Accordingly, instants of time for which radargramms exhibit entropy values greater than a prescribed threshold are “silenced.” Numerical results are presented in order to show the effectiveness of the entropy-based clutter rejection algorithm. Moreover, a comparison with the standard average trace subtraction is also included.

  4. Density and temperature diagnostics of a Ne-like germanium plasma created by laser

    International Nuclear Information System (INIS)

    Berthier, E.; Bourgade, J.L.; Combis, P.; Jacquemot, S.; Le Breton, J.P.; Louis-Jacquet, M.; Naccache, D.; Nail, M.; Peyrusse, O.

    1987-01-01

    In the framework of X-ray laser studies, experiments on Ne-like Ge plasma have been performed by laser irradiation at λ = 1.053 μm. Amplification in lasing transitions has been observed by varying the plasma length. Theoretical calculations of excited level population allow us to determine density and temperature from line intensity ratios

  5. Development of high-power optically-pumped far-infrared lasers for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, Masanobu; Yamanaka, Tatsuhiko; Mitsuishi, Akiyoshi; Fujita, Shigeru; Tsunawaki, Yoshiaki.

    1982-01-01

    The activities for developing an over 0.1-MW optically-pumped 385-μm D 2 O laser and a CW optically-pumped 382.9-μm CH 2 F 2 laser as local oscillator for measurement of ion temperature in Tokamaks are described. (author)

  6. Picosecond streak camera diagnostics of CO2 laser-produced plasmas

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; Marjoribanks, R.S.; Sancton, R.W.; Enright, G.D.; Richardson, M.C.

    1979-01-01

    The interaction of intense laser radiation with solid targets is currently of considerable interest in laser fusion studies. Its understanding requires temporal knowledge of both laser and plasma parameters on a picosecond time scale. In this paper we describe the progress we have recently made in analysing, with picosecond time resolution, various features of intense nanosecond CO 2 laser pulse interaction experiments. An infrared upconversion scheme, having linear response and <20 ps temporal resolution, has been utilized to characterise the 10 μm laser pulse. Various features of the interaction have been studied with the aid of picosecond IR and x-ray streak cameras. These include the temporal and spatial characteristics of high harmonic emission from the plasma, and the temporal development of the x-ray continuum spectrum. (author)

  7. Can and should value-based pricing be applied to molecular diagnostics?

    Science.gov (United States)

    Garau, Martina; Towse, Adrian; Garrison, Louis; Housman, Laura; Ossa, Diego

    2013-01-01

    Current pricing and reimbursement systems for diagnostics are not efficient. Prices for diagnostics are often driven by administrative practices and expected production cost. The purpose of the paper is to discuss how a value-based pricing framework being used to ensure efficient use and price of medicines could also be applied to diagnostics. Diagnostics not only facilitates health gain and cost savings, but also information to guide patients' decisions on interventions and their future 'behaviors'. For value assessment processes we recommend a two-part approach. Companion diagnostics introduced at the launch of the drug should be assessed through new drug assessment processes considering a broad range of value elements and a balanced analysis of diagnostic impacts. A separate diagnostic-dedicated committee using value-based pricing principles should review other diagnostics lying outside the companion diagnostics-and-drug 'at-launch' situation.

  8. Influence of excited state spatial distributions on plasma diagnostics: Atmospheric pressure laser-induced He-H2 plasma

    Science.gov (United States)

    Monfared, Shabnam K.; Hüwel, Lutz

    2012-10-01

    Atmospheric pressure plasmas in helium-hydrogen mixtures with H2 molar concentrations ranging from 0.13% to 19.7% were investigated at times from 1 to 25 μs after formation by a Q-switched Nd:YAG laser. Spatially integrated electron density values are obtained using time resolved optical emission spectroscopic techniques. Depending on mixture concentration and delay time, electron densities vary from almost 1017 cm-3 to about 1014 cm-3. Helium based results agree reasonably well with each other, as do values extracted from the Hα and Hβ emission lines. However, in particular for delays up to about 7 μs and in mixtures with less than 1% hydrogen, large discrepancies are observed between results obtained from the two species. Differences decrease with increasing hydrogen partial pressure and/or increasing delay time. In mixtures with molecular hydrogen fraction of 7% or more, all methods yield electron densities that are in good agreement. These findings seemingly contradict the well-established idea that addition of small amounts of hydrogen for diagnostic purposes does not perturb the plasma. Using Abel inversion analysis of the experimental data and a semi-empirical numerical model, we demonstrate that the major part of the detected discrepancies can be traced to differences in the spatial distributions of excited helium and hydrogen neutrals. The model yields spatially resolved emission intensities and electron density profiles that are in qualitative agreement with experiment. For the test case of a 1% H2 mixture at 5 μs delay, our model suggests that high electron temperatures cause an elevated degree of ionization and thus a reduction of excited hydrogen concentration relative to that of helium near the plasma center. As a result, spatially integrated analysis of hydrogen emission lines leads to oversampling of the plasma perimeter and thus to lower electron density values compared to those obtained from helium lines.

  9. Single event upset threshold estimation based on local laser irradiation

    International Nuclear Information System (INIS)

    Chumakov, A.I.; Egorov, A.N.; Mavritsky, O.B.; Yanenko, A.V.

    1999-01-01

    An approach for estimation of ion-induced SEU threshold based on local laser irradiation is presented. Comparative experiment and software simulation research were performed at various pulse duration and spot size. Correlation of single event threshold LET to upset threshold laser energy under local irradiation was found. The computer analysis of local laser irradiation of IC structures was developed for SEU threshold LET estimation. The correlation of local laser threshold energy with SEU threshold LET was shown. Two estimation techniques were suggested. The first one is based on the determination of local laser threshold dose taking into account the relation of sensitive area to local irradiated area. The second technique uses the photocurrent peak value instead of this relation. The agreement between the predicted and experimental results demonstrates the applicability of this approach. (authors)

  10. Screen printed paper-based diagnostic devices with polymeric inks.

    Science.gov (United States)

    Sun, Ju-Yen; Cheng, Chao-Min; Liao, Ying-Chih

    2015-01-01

    A simple and low-cost fabrication method for paper-based diagnostic devices (PBDDs) is described in this study. Street-available polymer solutions were screen printed onto filter papers to create hydrophobic patterns for fluidic channels. In order to obtain fully functional hydrophobic patterns for fluids, the original polymer solutions were diluted with butyl acetate to yield a suitable viscosity range between 30-200 cP for complete patterning on paper. Typical pH and glucose tests with color indicators were performed on the screen printed PBDDs. Images of the PBDDs were analyzed by computers to obtain calibration curves for pH between 2 and 12 and glucose concentration ranging from 10-1000 mmol dm(-3). Detection of formaldehyde in acetone was also carried out to show the possibility of using this PBBD for analytical detection with organic solvents. An exemplar PBDD with simultaneous pH and glucose detection was also used to demonstrate the feasibility of applying this technique for realistic diagnostic applications.

  11. Extracellular gadolinium-based contrast media: Differences in diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Molen, Aart J. van der [Department of Radiology C-2S, Leiden University Medical Centre, Albinusdreef 2, NL-2333 ZA Leiden (Netherlands)], E-mail: molen@lumc.nl; Bellin, Marie-France [Universite Paris-Sud XI, AP-HP, Service de Radiologie, Hopital Paul Brousse, 12-14 Avenue Paul Vaillant Couturier, F-94804 Villejuif Cedex (France)

    2008-05-15

    Since the introduction of the first gadolinium-based contrast agent (Gd-CA) in 1988 it has become clear that these agents significantly improve the diagnostic efficacy of MRI. Studies on single agents have shown that, in comparison to unenhanced sequences, all agents help to improve the detection and delineation of lesions which can alter diagnosis in up to 40% of patients. Doubling or tripling the standard dose of 0.1 mmol/kg body weight may be beneficial for selected indications (e.g. brain perfusion, equivocal single dose study in MRI for brain metastasis, small vessel MR angiography). A more limited number of studies have compared the various agents. These studies do not show clinically significant differences in diagnostic efficacy between the various extracellular Gd-CA. Agents with higher concentration or protein binding may be relatively better suitable for selected applications (e.g. perfusion MRI). The higher relaxivity agents may be used in somewhat lower doses than the extracellular agents.

  12. Extracellular gadolinium-based contrast media: Differences in diagnostic efficacy

    International Nuclear Information System (INIS)

    Molen, Aart J. van der; Bellin, Marie-France

    2008-01-01

    Since the introduction of the first gadolinium-based contrast agent (Gd-CA) in 1988 it has become clear that these agents significantly improve the diagnostic efficacy of MRI. Studies on single agents have shown that, in comparison to unenhanced sequences, all agents help to improve the detection and delineation of lesions which can alter diagnosis in up to 40% of patients. Doubling or tripling the standard dose of 0.1 mmol/kg body weight may be beneficial for selected indications (e.g. brain perfusion, equivocal single dose study in MRI for brain metastasis, small vessel MR angiography). A more limited number of studies have compared the various agents. These studies do not show clinically significant differences in diagnostic efficacy between the various extracellular Gd-CA. Agents with higher concentration or protein binding may be relatively better suitable for selected applications (e.g. perfusion MRI). The higher relaxivity agents may be used in somewhat lower doses than the extracellular agents

  13. Image standards in Tissue-Based Diagnosis (Diagnostic Surgical Pathology

    Directory of Open Access Journals (Sweden)

    Vollmer Ekkehard

    2008-04-01

    Full Text Available Abstract Background Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. Aims To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. Theory and experiences Images used in tissue-based diagnosis present with pathology – specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease – image combination, human – diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image

  14. Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

    Science.gov (United States)

    deBoer, Gary; Scott, Carl

    2003-01-01

    Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal

  15. Detection of angiospastic disorders in the microcirculatory bed using laser diagnostics technologies

    Directory of Open Access Journals (Sweden)

    Irina N. Makovik

    2018-01-01

    Thus, the evaluation of combined noninvasive optical diagnostic method use, the cold pressor test and proposed diagnostic criteria showed a positive result. This approach can be used to detect the presence of possible angiospastic disorders and related complications, as well as microcirculatory bed disorders against the background of other diseases.

  16. Nanoparticles for diagnostics and laser medical treatment of cartilage in orthopaedics

    Science.gov (United States)

    Baum, O. I.; Soshnikova, Yu. M.; Omelchenko, A. I.; Sobol, Emil

    2013-02-01

    Laser reconstruction of intervertebral disc (LRD) is a new technique which uses local, non-destructive laser irradiation for the controlled activation of regenerative processes in a targeted zone of damaged disc cartilage. Despite pronounced advancements of LRD, existing treatments may be substantially improved if laser radiation is absorbed near diseased and/or damaged regions in cartilage so that required thermomechanical stress and strain at chondrocytes may be generated and non-specific injury reduced or eliminated. The aims of the work are to study possibility to use nanoparticles (NPs) to provide spatial specificity for laser regeneration of cartilage. Two types of porcine joint cartilage have been impregnated with magnetite NPs: 1) fresh cartilage; 2) mechanically damaged cartilage. NPs distribution was studied using transition electron microscopy, dynamic light scattering and analytical ultracentrifugation techniques. Laser radiation and magnetic field have been applied to accelerate NPs impregnation. It was shown that NPs penetrate by diffusion into the mechanically damaged cartilage, but do not infiltrate healthy cartilage. Temperature dynamics in cartilage impregnated with NPs have been theoretically calculated and measurements using an IR thermo vision system have been performed. Laser-induced alterations of cartilage structure and cellular surviving have been studied for cartilage impregnated with NPs using histological and histochemical techniques. Results of our study suggest that magnetite NPs might be used to provide spatial specificity of laser regeneration. When damaged, the regions of cartilage impreganted with NPs have higher absorption of laser radiation than that for healthy areas. Regions containing NPs form target sites that can be used to generate laser-induced thermo mechanical stress leading to regeneration of cartilage of hyaline type.

  17. Chemistry, spectroscopy and isotope separation of zirconium and its compounds as revealed by laser diagnostics of laser produced metal beams

    International Nuclear Information System (INIS)

    Hackett, P.A.; Humphries, M.; Rayner, D.M.; Bourne, O.L.; Mitchell, A.

    1986-01-01

    Recent work from the author's laboratory on zirconium beams is reviewed. Zirconium metal beams have been produced by laser vaporization of solid zirconium targets coupled with supersonic expansion of helium gas. The resultant supersonic metal beam is shown to present an ideal environment for various spectroscopic techniques. The state distribution of zirconium atoms in the beam is obtained from low resolution laser induced fluorescence (LIF) studies. High resolution LIF studies give information on the hyperfine splitting in the ground state of the zirconium-91 isotope. Information on the hyperfine splitting in the excited state is obtained from quantum beat spectroscopy. Low resolution 2 color multiphoton ionization spectroscopy using a XeCl laser allows isotope separation of all isotopes of zirconium. These metal beams are highly reactive and can be used to produce novel chemical species. The results of two studies in which a reactant is added to the expansion gas are reported here. Zirconium oxide (ZrO), a molecule observed in the emission spectra of cool stars and in laboratory studies at high temperatures, is produced in a low temperature, collision free environment by adding small quantities of oxygen to the expansion gas. Zirconium fluoride (ZrF), a molecule previously unobserved, is produced by the addition of small quantities of CF/sub 4/

  18. Method for assessing the reliability of molecular diagnostics based on multiplexed SERS-coded nanoparticles.

    Directory of Open Access Journals (Sweden)

    Steven Y Leigh

    Full Text Available Surface-enhanced Raman scattering (SERS nanoparticles have been engineered to generate unique fingerprint spectra and are potentially useful as bright contrast agents for molecular diagnostics. One promising strategy for biomedical diagnostics and imaging is to functionalize various particle types ("flavors", each emitting a unique spectral signature, to target a large multiplexed panel of molecular biomarkers. While SERS particles emit narrow spectral features that allow them to be easily separable under ideal conditions, the presence of competing noise sources and background signals such as detector noise, laser background, and autofluorescence confounds the reliability of demultiplexing algorithms. Results obtained during time-constrained in vivo imaging experiments may not be reproducible or accurate. Therefore, our goal is to provide experimentalists with a metric that may be monitored to enforce a desired bound on accuracy within a user-defined confidence level. We have defined a spectral reliability index (SRI, based on the output of a direct classical least-squares (DCLS demultiplexing routine, which provides a measure of the reliability of the computed nanoparticle concentrations and ratios. We present simulations and experiments to demonstrate the feasibility of this strategy, which can potentially be utilized for a range of instruments and biomedical applications involving multiplexed SERS nanoparticles.

  19. Laser-based measuring equipment controlled by microcomputer

    International Nuclear Information System (INIS)

    Miron, N.; Sporea, D.; Velculescu, V.G.; Petre, M.

    1988-03-01

    Some laser-based measuring equipment controlled by microcomputer developed for industrial and scientific purposes are described. These equipments are intended for dial indicators verification, graduated rules measurement, and for very accurate measurement of the gravitational constant. (authors)

  20. Electrically pumped graphene-based Landau-level laser

    Science.gov (United States)

    Brem, Samuel; Wendler, Florian; Winnerl, Stephan; Malic, Ermin

    2018-03-01

    Graphene exhibits a nonequidistant Landau quantization with tunable Landau-level (LL) transitions in the technologically desired terahertz spectral range. Here, we present a strategy for an electrically driven terahertz laser based on Landau-quantized graphene as the gain medium. Performing microscopic modeling of the coupled electron, phonon, and photon dynamics in such a laser, we reveal that an inter-LL population inversion can be achieved resulting in the emission of coherent terahertz radiation. The presented paper provides a concrete recipe for the experimental realization of tunable graphene-based terahertz laser systems.

  1. Space- and time-resolved diagnostics of soft x-ray emission from laser plasmas

    International Nuclear Information System (INIS)

    Richardson, M.C.; Jaanimagi, P.A.; Chen, H.

    1988-01-01

    The analysis of soft x-ray emission from plasmas created by intense short-wavelength laser radiation can provide much useful information on the density, temperature and ionization distribution of the plasma. Until recently, limitations of sensitivity and the availability of suitable x-ray optical elements have restricted studies of soft x-ray emission from laser plasmas. In this paper, the authors describe novel instrumentation which provides high sensitivity in the soft x-ray spectrum with spatial and temporal resolution in the micron and picosecond ranges respectively. These systems exploit advances made in soft x-ray optic and electro-optic technology. Their application in current studies of laser fusion, x-ray lasers, and high density atomic physics are discussed

  2. Laser diagnostic and therapy of dental caries: the clinic point of view

    International Nuclear Information System (INIS)

    Paiva, Priscila Faria

    2001-01-01

    Dental caries's diagnosis is a major dentistry problem from the clinic point of view. The laser beam on the region of 655 nm induces the fluorescence of the compounds present in the hard tissue, quantifying differences between sound and carious enamel and dentine. Diagnodent (Kavo, Germany), showed to be effective regarding dental caries's diagnosis in the present research sampling. The Er:YAG laser (Kavo Key Laser 2, Germany) performed efficient cavity preparations in caries lesions of I and V class type, using up energies that ranged from 300 mJ to 350 mJ with 4 Hz repetition rate for the enamel; and from 250 mJ to 300 mJ with 4 Hz repetition rate for the dentine, and with 80 mJ with 6 Hz of repetition rate for laser conditioning. In the Er:YAG laser preparations no patient was anesthetized even when there were deeper cavities, and the maximum degree of pain ( which ranged from 0 to 10) was 4. In the control group with conventional high-speed drill two patients were anesthetized and the maximum degree of pain was 7. Restorations performed by conventional method of composite were equally satisfying both in caries groups of I and V class type and in the control group. The laser application in the operative dentistry office as a new method of diagnosis and dental preparations should be a good alternative to the use of the conventional dental drill. Nevertheless, dentistry practice has a lot to improve from technology progress, as well as new researches on laser dentistry are necessary in a long term. New types of lasers will come about and will increasingly improve the dental practice assistance and procedures quality. (author)

  3. Laser-based instrumentation for the detection of chemical agents

    International Nuclear Information System (INIS)

    Hartford, A. Jr.; Sander, R.K.; Quigley, G.P.; Radziemski, L.J.; Cremers, D.A.

    1982-01-01

    Several laser-based techniques are being evaluated for the remote, point, and surface detection of chemical agents. Among the methods under investigation are optoacoustic spectroscopy, laser-induced breakdown spectroscopy (LIBS), and synchronous detection of laser-induced fluorescence (SDLIF). Optoacoustic detection has already been shown to be capable of extremely sensitive point detection. Its application to remote sensing of chemical agents is currently being evaluated. Atomic emission from the region of a laser-generated plasma has been used to identify the characteristic elements contained in nerve (P and F) and blister (S and Cl) agents. Employing this LIBS approach, detection of chemical agent simulants dispersed in air and adsorbed on a variety of surfaces has been achieved. Synchronous detection of laser-induced fluorescence provides an attractive alternative to conventional LIF, in that an artificial narrowing of the fluorescence emission is obtained. The application of this technique to chemical agent simulants has been successfully demonstrated. 19 figures

  4. Research on laser cladding control system based on fuzzy PID

    Science.gov (United States)

    Zhang, Chuanwei; Yu, Zhengyang

    2017-12-01

    Laser cladding technology has a high demand for control system, and the domestic laser cladding control system mostly uses the traditional PID control algorithm. Therefore, the laser cladding control system has a lot of room for improvement. This feature is suitable for laser cladding technology, Based on fuzzy PID three closed-loop control system, and compared with the conventional PID; At the same time, the laser cladding experiment and friction and wear experiment were carried out under the premise of ensuring the reasonable control system. Experiments show that compared with the conventional PID algorithm in fuzzy the PID algorithm under the surface of the cladding layer is more smooth, the surface roughness increases, and the wear resistance of the cladding layer is also enhanced.

  5. Recent developments in the Thomson Parabola Spectrometer diagnostic for laser-driven multi-species ion sources

    International Nuclear Information System (INIS)

    Alejo, A.; Gwynne, D.; Doria, D.; Ahmed, H.; Borghesi, M.; Kar, S.; Carroll, D.C.; Clarke, R.J.; Neely, D.; Scott, G.G.

    2016-01-01

    Ongoing developments in laser-driven ion acceleration warrant appropriate modifications to the standard Thomson Parabola Spectrometer (TPS) arrangement in order to match the diagnostic requirements associated to the particular and distinctive properties of laser-accelerated beams. Here we present an overview of recent developments by our group of the TPS diagnostic aimed to enhance the capability of diagnosing multi-species high-energy ion beams. In order to facilitate discrimination between ions with same Z / A , a recursive differential filtering technique was implemented at the TPS detector in order to allow only one of the overlapping ion species to reach the detector, across the entire energy range detectable by the TPS. In order to mitigate the issue of overlapping ion traces towards the higher energy part of the spectrum, an extended, trapezoidal electric plates design was envisaged, followed by its experimental demonstration. The design allows achieving high energy-resolution at high energies without sacrificing the lower energy part of the spectrum. Finally, a novel multi-pinhole TPS design is discussed, that would allow angularly resolved, complete spectral characterization of the high-energy, multi-species ion beams.

  6. Recent developments in the Thomson Parabola Spectrometer diagnostic for laser-driven multi-species ion sources

    Science.gov (United States)

    Alejo, A.; Gwynne, D.; Doria, D.; Ahmed, H.; Carroll, D. C.; Clarke, R. J.; Neely, D.; Scott, G. G.; Borghesi, M.; Kar, S.

    2016-10-01

    Ongoing developments in laser-driven ion acceleration warrant appropriate modifications to the standard Thomson Parabola Spectrometer (TPS) arrangement in order to match the diagnostic requirements associated to the particular and distinctive properties of laser-accelerated beams. Here we present an overview of recent developments by our group of the TPS diagnostic aimed to enhance the capability of diagnosing multi-species high-energy ion beams. In order to facilitate discrimination between ions with same Z/A, a recursive differential filtering technique was implemented at the TPS detector in order to allow only one of the overlapping ion species to reach the detector, across the entire energy range detectable by the TPS. In order to mitigate the issue of overlapping ion traces towards the higher energy part of the spectrum, an extended, trapezoidal electric plates design was envisaged, followed by its experimental demonstration. The design allows achieving high energy-resolution at high energies without sacrificing the lower energy part of the spectrum. Finally, a novel multi-pinhole TPS design is discussed, that would allow angularly resolved, complete spectral characterization of the high-energy, multi-species ion beams.

  7. Dual purpose laser ablation-inductively coupled plasma mass spectrometry for pulsed laser deposition and diagnostics of thin film fabrication: preliminary study.

    Science.gov (United States)

    Azdejković, Mersida Janeva; van Elteren, Johannes Teun; Rozman, Kristina Zuzek; Jaćimović, Radojko; Sarantopoulou, Evangelia; Kobe, Spomenka; Cefalas, Alkiviadis Constantinos

    2009-08-15

    PLD (pulsed laser deposition) is an attractive technique to fabricate thin films with a stoichiometry reflecting that of the target material. Conventional PLD instruments are more or less black boxes in which PLD is performed virtually "blind", i.e. without having great control on the important PLD parameters. In this preliminary study, for the first time, a 213 nm Nd-YAG commercial laser ablation-inductively coupled plasma mass spectrometer (LA-ICPMS) intended for microanalysis work was used for PLD under atmospheric pressure and in and ex situ ICPMS analysis for diagnostics of the thin film fabrication process. A PLD demonstration experiment in a He atmosphere was performed with a Sm(13.8)Fe(82.2)Ta(4.0) target-Ta-coated silicon wafer substrate (contraption with defined geometry in the laser ablation chamber) to transfer the permanent magnetic properties of the target to the film. Although this paper is not dealing with the magnetic properties of the film, elemental analysis was applied as a means of depicting the PLD process. It was shown that in situ ICPMS monitoring of the ablation plume as a function of the laser fluence, beam diameter and repetition rate may be used to ensure the absence of large particles (normally having a stoichiometry somewhat different from the target). Furthermore, ex situ microanalysis of the deposited particles on the substrate, using the LA-ICPMS as an elemental mapping tool, allowed for the investigation of PLD parameters critical in the fabrication of a thin film with appropriate density, homogeneity and stoichiometry.

  8. Laser spot detection based on reaction diffusion

    Czech Academy of Sciences Publication Activity Database

    Vázquez-Otero, Alejandro; Khikhlukha, Danila; Solano-Altamirano, J. M.; Dormido, R.; Duro, N.

    2016-01-01

    Roč. 16, č. 3 (2016), s. 1-11, č. článku 315. ISSN 1424-8220 R&D Projects: GA MŠk EF15_008/0000162 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : laser spot detection * laser beam detection * reaction diffusion models * Fitzhugh-Nagumo model * reaction diffusion computation * Turing patterns Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.677, year: 2016

  9. Laser Scattering Diagnostic for Shock Front Arrival and Electron Number Density, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Three diagnostic methods are proposed for measuring properties of interest in the post-shock regions of a hypersonic bow shock wave that is used for studying...

  10. SOME ASPECTS OF SCANNING LASER OPHTHALMOSCOPY IN THE DIAGNOSTICS OF OPHTHALMOPATHOLOGY

    Directory of Open Access Journals (Sweden)

    S. A. Kochergin

    2017-01-01

    Full Text Available The exact diagnosis of the fundus pathology requires the most modern equipment use. This is mandatory for the selection of the most complete therapy and monitoring of ongoing treatment. At present, the method of scanning laser ophthalmoscopy is widely spread. However, for the earliest detection of the smallest pathological changes, data of the normal ocular fundus state using a scanning laser ophthalmoscope is necessary. Thus, the purpose of our research becomes relevant. Purpose: to give a characteristic of the fundus in patients without concomitant pathology with using various modes of a scanning laser ophthalmoscope. Patients and methods. 116 people (232 eyes at the age from 17 to 71 years (mean age 32.5±12 years were examined. The patients were divided into two groups. Group I: 81 patients (162 eyes with different ophthalmopathology. Group II: 35 people (70 eyes — practically healthy and did not have an anamnesis of consulting an ophthalmologist. Diagnosis of the patients’ fundus was performed using a scanning laser ophthalmoscopy with retro-mode imaging and autofluorescence registration. Results. After the conducted research features and regularities of the reflectivity distribution of laser beams from the fundus structures are revealed. Also a characteristic of various anatomical formations and zones of the fundus in the normal conditions is given when examined by a scanning laser ophthalmoscope. An algorithm for examining patients and analyzing the images was developed. Conclusion. The use of scanning laser ophthalmoscopy made possible to take a fresh look at the algorithms of diagnosing patients with fundus pathology. Understanding the normal conditions ofundus allowed an earlier detection of the smallest pathological changes in the retina. 

  11. Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, A. P., E-mail: APKuznetsov@mephi.ru [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) (Russian Federation); Buzinskij, O. I. [State Research Center Troitsk Institute for Innovation and Fusion Research (TRINITI) (Russian Federation); Gubsky, K. L.; Nikitina, E. A.; Savchenkov, A. V.; Tarasov, B. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) (Russian Federation); Tugarinov, S. N. [State Research Center Troitsk Institute for Innovation and Fusion Research (TRINITI) (Russian Federation)

    2015-12-15

    A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxide films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements.

  12. Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER

    International Nuclear Information System (INIS)

    Kuznetsov, A. P.; Buzinskij, O. I.; Gubsky, K. L.; Nikitina, E. A.; Savchenkov, A. V.; Tarasov, B. A.; Tugarinov, S. N.

    2015-01-01

    A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxide films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements

  13. ETHERNET BASED EMBEDDED SYSTEM FOR FEL DIAGNOSTICS AND CONTROLS

    International Nuclear Information System (INIS)

    Jianxun Yan; Daniel Sexton; Steven Moore; Albert Grippo; Kevin Jordan

    2006-01-01

    An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller was built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has the features of a low cost IOC, an open source real-time operating system, plug and play-like ease of installation and flexibility, and provides a much more localized solution

  14. Laser-Based Maintenance and Repair Technologies for Reactor Components

    International Nuclear Information System (INIS)

    Masaki Yoda; Naruhiko Mukai; Makoto Ochiai; Masataka Tamura; Satoshi Okada; Katsuhiko Sato; Motohiko Kimura; Yuji Sano; Noboru Saito; Seishi Shima; Tetsuo Yamamoto

    2004-01-01

    Toshiba has developed various laser-based maintenance and repair technologies and applied them to existing nuclear power plants. Laser-based technology is considered to be the best tool for remote processing in nuclear power plants, and particularly so for the maintenance and repair of reactor core components. Accessibility could be drastically improved by a simple handling system owing to the absence of reactive force against laser irradiation and the flexible optical fiber. For the preventive maintenance, laser peening (LP) technology was developed and applied to reactor components in operating BWR plants. LP is a novel process to improve residual stress from tensile to compressive on material surface layer by irradiating focused high-power laser pulses in water. We have developed a fiber-delivered LP system as a preventive maintenance measure against stress corrosion cracking (SCC). Laser ultrasonic testing (LUT) has a great potential to be applied to the remote inspection of reactor components. Laser-induced surface acoustic wave (SAW) inspection system was developed using a compact probe with a multi-mode optical fiber and an interferometer. The developed system successfully detected a micro slit of 0.5 mm depth on weld metal and heat-affected zone (HAZ). An artificial SCC was also detected by the system. We are developing a new LP system combined with LUT to treat the inner surface of bottom-mounted instruments (BMI) of PWR plants. Underwater laser seal welding (LSW) technology was also developed to apply surface crack. LSW is expected to isolate the crack tip from corrosive water environment and to stop the propagation of the crack. Rapid heating and cooling of the process minimize the heat effect, which extends the applicability to neutron-irradiated material. This paper describes recent advances in the development and application of such laser-based technologies. (authors)

  15. Diagnostics of Particles emitted from a Laser generated Plasma: Experimental Data and Simulations

    Science.gov (United States)

    Costa, Giuseppe; Torrisi, Lorenzo

    2018-01-01

    The charge particle emission form laser-generated plasma was studied experimentally and theoretically using the COMSOL simulation code. The particle acceleration was investigated using two lasers at two different regimes. A Nd:YAG laser, with 3 ns pulse duration and 1010 W/cm2 intensity, when focused on solid target produces a non-equilibrium plasma with average temperature of about 30-50 eV. An Iodine laser with 300 ps pulse duration and 1016 W/cm2 intensity produces plasmas with average temperatures of the order of tens keV. In both cases charge separation occurs and ions and electrons are accelerated at energies of the order of 200 eV and 1 MeV per charge state in the two cases, respectively. The simulation program permits to plot the charge particle trajectories from plasma source in vacuum indicating how they can be deflected by magnetic and electrical fields. The simulation code can be employed to realize suitable permanent magnets and solenoids to deflect ions toward a secondary target or detectors, to focalize ions and electrons, to realize electron traps able to provide significant ion acceleration and to realize efficient spectrometers. In particular it was applied to the study two Thomson parabola spectrometers able to detect ions at low and at high laser intensities. The comparisons between measurements and simulation is presented and discussed.

  16. Laser diagnodent: a comparative study with other diagnostic techniques; Laser diagnodent: estudo comparativo com outras tecnicas de diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, Reugma Rego

    2002-07-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  17. Utility of optical heterodyne displacement sensing and laser ultrasonics as in situ process control diagnostic for additive manufacturing

    Science.gov (United States)

    Manzo, Anthony J.; Helvajian, Henry

    2018-04-01

    An in situ process control monitor is presented by way of experimental results and simulations, which utilizes a pulsed laser ultrasonic source as a probe and an optical heterodyne displacement meter as a sensor. The intent is for a process control system that operates in near real time, is nonintrusive, and in situ: A necessary requirement for a serial manufacturing technology such as additive manufacturing (AM). We show that the diagnostic approach has utility in characterizing the local temperature, the area of the heat-affected zone, and the surface roughness (Ra ˜ 0.4 μm). We further demonstrate that it can be used to identify solitary defects (i.e., holes) on the order of 10 to 20 μm in diameter. Moreover, the technique shows promise in measuring properties of materials with features that have a small radius of curvature. We present results for a thin wire of ˜650 μm in diameter. By applying multiple pairs of probe-sensor systems, the diagnostic could also measure the local cooling rate on the scale of 1 μs. Finally, while an obvious application is used in AM technology, then all optical diagnostics could be applied to other manufacturing technologies.

  18. A laser based reusable microjet injector for transdermal drug delivery

    Science.gov (United States)

    Han, Tae-hee; Yoh, Jack J.

    2010-05-01

    A laser based needle-free liquid drug injection device has been developed. A laser beam is focused inside the liquid contained in the rubber chamber of microscale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is 125 μm and the injected microjet reaches an average velocity of 264 m/s. This device adds the time-varying feature of microjet to the current state of liquid injection for drug delivery.

  19. Efficient TEA CO2 laser based coating removal system

    CSIR Research Space (South Africa)

    Prinsloo, FJ

    2007-04-01

    Full Text Available stream_source_info Prinsloo_2007.pdf.txt stream_content_type text/plain stream_size 11617 Content-Encoding UTF-8 stream_name Prinsloo_2007.pdf.txt Content-Type text/plain; charset=UTF-8 Efficient TEA CO2 laser based... by keeping energy density below the damage threshold. The advantage of a pulsed TEA CO2 laser system is that a laser frequency and temporal profile can be chosen to maximize paint removal and concurrently minimize substrate damage. To achieve...

  20. Changing Histopathological Diagnostics by Genome-Based Tumor Classification

    Directory of Open Access Journals (Sweden)

    Michael Kloth

    2014-05-01

    Full Text Available Traditionally, tumors are classified by histopathological criteria, i.e., based on their specific morphological appearances. Consequently, current therapeutic decisions in oncology are strongly influenced by histology rather than underlying molecular or genomic aberrations. The increase of information on molecular changes however, enabled by the Human Genome Project and the International Cancer Genome Consortium as well as the manifold advances in molecular biology and high-throughput sequencing techniques, inaugurated the integration of genomic information into disease classification. Furthermore, in some cases it became evident that former classifications needed major revision and adaption. Such adaptations are often required by understanding the pathogenesis of a disease from a specific molecular alteration, using this molecular driver for targeted and highly effective therapies. Altogether, reclassifications should lead to higher information content of the underlying diagnoses, reflecting their molecular pathogenesis and resulting in optimized and individual therapeutic decisions. The objective of this article is to summarize some particularly important examples of genome-based classification approaches and associated therapeutic concepts. In addition to reviewing disease specific markers, we focus on potentially therapeutic or predictive markers and the relevance of molecular diagnostics in disease monitoring.

  1. An indicator cell assay for blood-based diagnostics.

    Directory of Open Access Journals (Sweden)

    Samuel A Danziger

    Full Text Available We have established proof of principle for the Indicator Cell Assay Platform™ (iCAP™, a broadly applicable tool for blood-based diagnostics that uses specifically-selected, standardized cells as biosensors, relying on their innate ability to integrate and respond to diverse signals present in patients' blood. To develop an assay, indicator cells are exposed in vitro to serum from case or control subjects and their global differential response patterns are used to train reliable, disease classifiers based on a small number of features. In a feasibility study, the iCAP detected pre-symptomatic disease in a murine model of amyotrophic lateral sclerosis (ALS with 94% accuracy (p-Value = 3.81E-6 and correctly identified samples from a murine Huntington's disease model as non-carriers of ALS. Beyond the mouse model, in a preliminary human disease study, the iCAP detected early stage Alzheimer's disease with 72% cross-validated accuracy (p-Value = 3.10E-3. For both assays, iCAP features were enriched for disease-related genes, supporting the assay's relevance for disease research.

  2. X-ray spectral line shapes for the excimer-laser-produced high density plasma diagnostics

    International Nuclear Information System (INIS)

    Magunov, A.; Faenov, A.; Skobelev, I.; Pikuz, T.; Batani, D.; Milani, M.; Conti, A.; Masini, A.; Costato, M.; Pozzi, A.; Turcu, E.; Allot, R.; Lisi, N.; Koenig, M.; Benuzzi, A.; Flora, F.; Letardi, T.; Palladino, L.; Reale, A.

    1997-01-01

    The time and space-integrated emission spectra measurements have been performed in plasma produced by 308 nm wavelength XeCl laser radiation (I L =(4-10)·10 12 W/cm 2 , τ=10 ns) and by 248 nm wavelength KrF laser pulse train radiation (I L =5·10 15 W/cm 2 , τ=7 ps, 16 pulses in train) on CF n plane target. The lines' shapes and intensities modeling of Lyman series and He-like ion resonance series of fluorine up to n=7 by fitting experimental data shows the considerable difference of plasma formation features for these two sets of the laser pulse parameters

  3. Laser spot welding of cobalt-based amorphous metal foils

    International Nuclear Information System (INIS)

    Runchev, Dobre; Dorn, Lutc; Jaferi, Seifolah; Purbst, Detler

    1997-01-01

    The results concerning weldability of amorphous alloy (VAC 6025F) in shape of foils and the quality of laser-spot welded joints are presented in this paper. The aim of the research was the production of a high quality welding joint, by preserving the amorphous structure. The quality of the joint was tested by shear strength analysis and microhardness measuring. The metallographic studies were made by using optical microscope and SEM. The results show that (1) overlapped Co based amorphous metals foils can be welded with high-quality by a pulsed Nd: YAG-Laser, but only within a very narrow laser parameter window; (2) the laser welded spots show comparably high strength as the basic material; (3) the structure of the welded spot remains amorphous, so that the same characteristics as the base material can be achieved. (author)

  4. Fiber laser welding of nickel based superalloy Inconel 625

    Science.gov (United States)

    Janicki, Damian M.

    2013-01-01

    The paper describes the application of single mode high power fiber laser (HPFL) for the welding of nickel based superalloy Inconel 625. Butt joints of Inconel 625 sheets 0,8 mm thick were laser welded without an additional material. The influence of laser welding parameters on weld quality and mechanical properties of test joints was studied. The quality and mechanical properties of the joints were determined by means of tensile and bending tests, and micro hardness tests, and also metallographic examinations. The results showed that a proper selection of laser welding parameters provides non-porous, fully-penetrated welds with the aspect ratio up to 2.0. The minimum heat input required to achieve full penetration butt welded joints with no defect was found to be 6 J/mm. The yield strength and ultimate tensile strength of the joints are essentially equivalent to that for the base material.

  5. Distributed Feedback Laser Based on Single Crystal Perovskite

    Science.gov (United States)

    Sun, Shang; Xiao, Shumin; Song, Qinghai

    2017-06-01

    We demonstrate a single crystal perovskite based, with grating-structured photoresist on top, highly polarized distributed feedback laser. A lower laser threshold than the Fabry-Perot mode lasers from the same single crystal CH3NH3PbBr3 microplate was obtained. Single crystal CH3NH3PbBr3 microplates was synthesized with one-step solution processed precipitation method. Once the photoresist on top of the microplate was patterned with electron beam, the device was realized. This one-step fabrication process utilized the advantage of single crystal to the greatest extend. The ultra-low defect density in single crystalline microplate offer an opportunity for lower threshold lasing action compare with poly-crystal perovskite films. In the experiment, the lasing action based on the distributed feedback grating design was found with lower threshold and higher intensity than the Fabry-Perot mode lasers supported by the flat facets of the same microplate.

  6. Compact silicon photonics-based multi laser module for sensing

    Science.gov (United States)

    Ayotte, S.; Costin, F.; Babin, A.; Paré-Olivier, G.; Morin, M.; Filion, B.; Bédard, K.; Chrétien, P.; Bilodeau, G.; Girard-Deschênes, E.; Perron, L.-P.; Davidson, C.-A.; D'Amato, D.; Laplante, M.; Blanchet-Létourneau, J.

    2018-02-01

    A compact three-laser source for optical sensing is presented. It is based on a low-noise implementation of the Pound Drever-Hall method and comprises high-bandwidth optical phase-locked loops. The outputs from three semiconductor distributed feedback lasers, mounted on thermo-electric coolers (TEC), are coupled with micro-lenses into a silicon photonics (SiP) chip that performs beat note detection and several other functions. The chip comprises phase modulators, variable optical attenuators, multi-mode-interference couplers, variable ratio tap couplers, integrated photodiodes and optical fiber butt-couplers. Electrical connections between a metallized ceramic and the TECs, lasers and SiP chip are achieved by wirebonds. All these components stand within a 35 mm by 35 mm package which is interfaced with 90 electrical pins and two fiber pigtails. One pigtail carries the signals from a master and slave lasers, while another carries that from a second slave laser. The pins are soldered to a printed circuit board featuring a micro-processor that controls and monitors the system to ensure stable operation over fluctuating environmental conditions. This highly adaptable multi-laser source can address various sensing applications requiring the tracking of up to three narrow spectral features with a high bandwidth. It is used to sense a fiber-based ring resonator emulating a resonant fiber optics gyroscope. The master laser is locked to the resonator with a loop bandwidth greater than 1 MHz. The slave lasers are offset frequency locked to the master laser with loop bandwidths greater than 100 MHz. This high performance source is compact, automated, robust, and remains locked for days.

  7. Innovative laser based solar cell scribing

    Science.gov (United States)

    Frei, Bruno; Schneeberger, Stefan; Witte, Reiner

    2011-03-01

    The solar photovoltaic market is continuously growing utilizing boths crystalline silicon (c-Si) as well as thin film technologies. This growth is directly dependant on the manufacturing costs for solar cells. Factors for cost reduction are innovative ideas for an optimization of precision and throughput. Lasers are excellent tools to provide highly efficient processes with impressive accuracy. They need to be used in combination with fast and precise motion systems for a maximum gain in the manufacturing process, yielding best cost of ownership. In this article such an innovative solution is presented for laser scribing in thin film Si modules. A combination of a new glass substrate holding system combined with a fast and precise motion system is the foundation for a cost effective scribing machine. In addition, the advantages of fiber lasers in beam delivery and beam quality guarantee not only shorter setup and down times but also high resolution and reproducibility for the scribing processes P1, P2 and P3. The precision of the whole system allows to reduce the dead zone to a minimum and therefore to improve the efficiency of the modules.

  8. Laser based analytical spectroscopy of uranium

    International Nuclear Information System (INIS)

    Argekar, A.A.; Kulkarni, M.J.; Godbole, S.V.; Page, A.G.; Samuel, J.K.; Paranjape, D.B.; Singh Mudher, K.D.

    1992-01-01

    Analytical spectroscopy of uranium has been studied using a XeCl excimer laser, using the fluorescence emission of U(VI) ions doped in a solid solution of sodium fluoride (NaF) and sodium chloride (NaCl) in 3:2 proportion. An electronic circuitry involving time-gating of the photomultiplier tube and facility to integrate the analytical signal over ten laser pulses has been developed to enable laser operation and signal detection with high S/N ratio. The matrix enhanced U(VI) fluorescence emission is free from chemical and spectral interferences due to the concomitant presence of ten metallic elements generally associated with uranium. The digital signal output is highly precise and does not saturate upto 5 ppm uranium concentration. X-ray diffraction patterns obtained for uranium doped compounds at 2.5% and 10% dopant concentrations are broadly similar to that of Na 2 U 2 O 7 . The detailed studies have, however, revealed fine structure for individual peaks, thereby, revealing the formation of sodium fluoro-uranate complex which is responsible for the enhanced intensity of fluorescence emission. (author). 10 refs., 6 figs., 2 tabs

  9. Laser ablation method for cleaning of mirror surfaces for optical diagnostic systems at the ITER

    International Nuclear Information System (INIS)

    Aleksandrova, A.S.; Kuznetsov, A.P.; Gubskij, K.L.; Petrovskij, V.N.; Savelov, A.S.; Shtamm, V.G.; Buzhinskij, O.I.

    2012-01-01

    The possibility of cleaning metallic mirrors from films with complex composition by pulsed radiation from a fiber laser has been experimentally examined. It has been shown that the high initial reflection characteristics of optical elements can be recovered by choosing regimes of the action of radiation on the surface with a deposited film [ru

  10. Silicon carbide detectors for diagnostics of ion emission from laser plasmas

    International Nuclear Information System (INIS)

    Musumeci, Paolo; Zimbone, Massimo; Calcagno, Lucia; Cutroneo, Maria; Torrisi, Lorenzo; Velyhan, Andry

    2014-01-01

    Silicon carbide (SiC) detectors have been employed to analyze the multi-MeV ions generated from laser plasma. The irradiation was performed with the iodine laser of Prague Asterix Laser System Laboratory operating at 10 16  W cm −2 pulse intensity. Thin metallic and polymeric targets were irradiated and the produced plasmas were monitored in the forward direction. The use of SiC detectors ensures the cutting of the visible and soft UV radiation emitted from plasma, enhancing the sensitivity to protons and very fast heavy ions. The time-of-flight spectra obtained by irradiating polymeric films with high laser pulse energy produce protons with energy in the range 1.0–2.5 MeV and all the charge states of carbon ions. The metallic Al target allows achieving energy up to 3.0 MeV for protons and 40 MeV for Al ions. All the results reveal the high performances of these detectors in terms of resolution and response time. (paper)

  11. Case-based reasoning diagnostic technique based on multi-attribute similarity

    Energy Technology Data Exchange (ETDEWEB)

    Makoto, Takahashi [Tohoku University, Miyagi (Japan); Akio, Gofuku [Okayama University, Okayamaa (Japan)

    2014-08-15

    Case-based diagnostic technique has been developed based on the multi-attribute similarity. Specific feature of the developed system is to use multiple attributes of process signals for similarity evaluation to retrieve a similar case stored in a case base. The present technique has been applied to the measurement data from Monju with some simulated anomalies. The results of numerical experiments showed that the present technique can be utilizes as one of the methods for a hybrid-type diagnosis system.

  12. 77 FR 13367 - General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-06

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0157] General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment Facility, Wilmington, NC AGENCY: Nuclear Regulatory... Impact Statement (EIS) for the proposed General Electric- Hitachi Global Laser Enrichment, LLC (GLE...

  13. Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET) Velocimetry in Flow and Combustion Diagnostics

    Science.gov (United States)

    Jiang, Naibo; Halls, Benjamin R.; Stauffer, Hans U.; Roy, Sukesh; Danehy, Paul M.; Gord, James R.

    2016-01-01

    Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET), a non-seeded ultrafast-laser-based velocimetry technique, is demonstrated in reactive and non-reactive flows. STARFLEET is pumped via a two-photon resonance in N2 using 202.25-nm 100-fs light. STARFLEET greatly reduces the per-pulse energy required (30 µJ/pulse) to generate the signature FLEET emission compared to the conventional FLEET technique (1.1 mJ/pulse). This reduction in laser energy results in less energy deposited in the flow, which allows for reduced flow perturbations (reactive and non-reactive), increased thermometric accuracy, and less severe damage to materials. Velocity measurements conducted in a free jet of N2 and in a premixed flame show good agreement with theoretical velocities and further demonstrate the significantly less-intrusive nature of STARFLEET.

  14. Smartphone-Based Food Diagnostic Technologies: A Review.

    Science.gov (United States)

    Rateni, Giovanni; Dario, Paolo; Cavallo, Filippo

    2017-06-20

    A new generation of mobile sensing approaches offers significant advantages over traditional platforms in terms of test speed, control, low cost, ease-of-operation, and data management, and requires minimal equipment and user involvement. The marriage of novel sensing technologies with cellphones enables the development of powerful lab-on-smartphone platforms for many important applications including medical diagnosis, environmental monitoring, and food safety analysis. This paper reviews the recent advancements and developments in the field of smartphone-based food diagnostic technologies, with an emphasis on custom modules to enhance smartphone sensing capabilities. These devices typically comprise multiple components such as detectors, sample processors, disposable chips, batteries and software, which are integrated with a commercial smartphone. One of the most important aspects of developing these systems is the integration of these components onto a compact and lightweight platform that requires minimal power. To date, researchers have demonstrated several promising approaches employing various sensing techniques and device configurations. We aim to provide a systematic classification according to the detection strategy, providing a critical discussion of strengths and weaknesses. We have also extended the analysis to the food scanning devices that are increasingly populating the Internet of Things (IoT) market, demonstrating how this field is indeed promising, as the research outputs are quickly capitalized on new start-up companies.

  15. Smartphone-Based Food Diagnostic Technologies: A Review

    Directory of Open Access Journals (Sweden)

    Giovanni Rateni

    2017-06-01

    Full Text Available A new generation of mobile sensing approaches offers significant advantages over traditional platforms in terms of test speed, control, low cost, ease-of-operation, and data management, and requires minimal equipment and user involvement. The marriage of novel sensing technologies with cellphones enables the development of powerful lab-on-smartphone platforms for many important applications including medical diagnosis, environmental monitoring, and food safety analysis. This paper reviews the recent advancements and developments in the field of smartphone-based food diagnostic technologies, with an emphasis on custom modules to enhance smartphone sensing capabilities. These devices typically comprise multiple components such as detectors, sample processors, disposable chips, batteries and software, which are integrated with a commercial smartphone. One of the most important aspects of developing these systems is the integration of these components onto a compact and lightweight platform that requires minimal power. To date, researchers have demonstrated several promising approaches employing various sensing techniques and device configurations. We aim to provide a systematic classification according to the detection strategy, providing a critical discussion of strengths and weaknesses. We have also extended the analysis to the food scanning devices that are increasingly populating the Internet of Things (IoT market, demonstrating how this field is indeed promising, as the research outputs are quickly capitalized on new start-up companies.

  16. Smartphone-Based Food Diagnostic Technologies: A Review

    Science.gov (United States)

    Rateni, Giovanni; Dario, Paolo; Cavallo, Filippo

    2017-01-01

    A new generation of mobile sensing approaches offers significant advantages over traditional platforms in terms of test speed, control, low cost, ease-of-operation, and data management, and requires minimal equipment and user involvement. The marriage of novel sensing technologies with cellphones enables the development of powerful lab-on-smartphone platforms for many important applications including medical diagnosis, environmental monitoring, and food safety analysis. This paper reviews the recent advancements and developments in the field of smartphone-based food diagnostic technologies, with an emphasis on custom modules to enhance smartphone sensing capabilities. These devices typically comprise multiple components such as detectors, sample processors, disposable chips, batteries and software, which are integrated with a commercial smartphone. One of the most important aspects of developing these systems is the integration of these components onto a compact and lightweight platform that requires minimal power. To date, researchers have demonstrated several promising approaches employing various sensing techniques and device configurations. We aim to provide a systematic classification according to the detection strategy, providing a critical discussion of strengths and weaknesses. We have also extended the analysis to the food scanning devices that are increasingly populating the Internet of Things (IoT) market, demonstrating how this field is indeed promising, as the research outputs are quickly capitalized on new start-up companies. PMID:28632188

  17. Clinical advances of nanocarrier-based cancer therapy and diagnostics.

    Science.gov (United States)

    Luque-Michel, Edurne; Imbuluzqueta, Edurne; Sebastián, Víctor; Blanco-Prieto, María J

    2017-01-01

    Cancer is a leading cause of death worldwide and efficient new strategies are urgently needed to combat its high mortality and morbidity statistics. Fortunately, over the years, nanotechnology has evolved as a frontrunner in the areas of imaging, diagnostics and therapy, giving the possibility of monitoring, evaluating and individualizing cancer treatments in real-time. Areas covered: Polymer-based nanocarriers have been extensively studied to maximize cancer treatment efficacy and minimize the adverse effects of standard therapeutics. Regarding diagnosis, nanomaterials like quantum dots, iron oxide nanoparticles or gold nanoparticles have been developed to provide rapid, sensitive detection of cancer and, therefore, facilitate early treatment and monitoring of the disease. Therefore, multifunctional nanosystems with both imaging and therapy functionalities bring us a step closer to delivering precision/personalized medicine in the cancer setting. Expert opinion: There are multiple barriers for these new nanosystems to enter the clinic, but it is expected that in the near future, nanocarriers, together with new 'targeted drugs', could replace our current treatments and cancer could become a nonfatal disease with good recovery rates. Joint efforts between scientists, clinicians, the pharmaceutical industry and legislative bodies are needed to bring to fruition the application of nanosystems in the clinical management of cancer.

  18. Wind Turbine Bearing Diagnostics Based on Vibration Monitoring

    Science.gov (United States)

    Kadhim, H. T.; Mahmood, F. H.; Resen, A. K.

    2018-05-01

    Reliability maintenance can be considered as an accurate condition monitoring system which increasing beneficial and decreasing the cost production of wind energy. Supporting low friction of wind turbine rotating shaft is the main task of rolling element bearing and it is the main part that suffers from failure. The rolling failures elements have an economic impact and may lead to malfunctions and catastrophic failures. This paper concentrates on the vibration monitoring as a Non-Destructive Technique for assessing and demonstrates the feasibility of vibration monitoring for small wind turbine bearing defects based on LabVIEW software. Many bearings defects were created, such as inner race defect, outer race defect, and ball spin defect. The spectra data were recorded and compared with the theoretical results. The accelerometer with 4331 NI USB DAQ was utilized to acquiring, analyzed, and recorded. The experimental results were showed the vibration technique is suitable for diagnostic the defects that will be occurred in the small wind turbine bearings and developing a fault in the bearing which leads to increasing the vibration amplitude or peaks in the spectrum.

  19. Synchronization and Characterization of an Ultra-Short Laser for Photoemission and Electron-Beam Diagnostics Studies at a Radio Frequency Photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Timothy; Ruan, Jinhao; Piot, Philippe; Lumpkin, Alex

    2012-03-01

    A commercially-available titanium-sapphire laser system has recently been installed at the Fermilab A0 photoinjector laboratory in support of photoemission and electron beam diagnostics studies. The laser system is synchronized to both the 1.3-GHz master oscillator and a 1-Hz signal use to trigger the radiofrequency system and instrumentation acquisition. The synchronization scheme and performance are detailed. Long-term temporal and intensity drifts are identified and actively suppressed to within 1 ps and 1.5%, respectively. Measurement and optimization of the laser's temporal profile are accomplished using frequency-resolved optical gating.

  20. Laser-Based Spatio-Temporal Characterisation of Port Fuel Injection (PFI Sprays

    Directory of Open Access Journals (Sweden)

    C. T. N. Anand

    2010-06-01

    Full Text Available In the present work, detailed laser-based diagnostic experiments were conducted to characterise the spray from low pressure 2-hole and 4-hole Port Fuel Injection (PFI injectors. The main objective of the work included obtaining quantitative information of the spatio-temporal spray structure of such low-pressure gasoline sprays. A novel approach involving a combination of techniques such as Mie scattering, Granulometry, and Laser Sheet Dropsizing (LSD was used to study the spray structure. The droplet sizes, distributions with time, Sauter Mean Diameters (SMD, droplet velocities, cone angles and spray tip penetrations of the sprays from the injectors were determined. The spray from these injectors is found to be ‘pencil like’ and not dispersed as in high pressure sprays. The application of the above mentioned techniques provides two-dimensional SMD contours of the entire spray at different instants of time, with reasonable accuracy.

  1. Towards a blood-based diagnostic panel for bipolar disorder

    NARCIS (Netherlands)

    F. Haenisch (Frieder); J.D. Cooper (Jason); A. Reif (Andreas); S. Kittel-Schneider (Sarah); J. Steiner (Johann); F.M. Leweke (Marcus); M. Rothermundt (Matthias); N.J.M. van Beveren (Nico); B. Crespo-Facorro (Benedicto); D. Niebuhr (David); D. Cowan (David); N. Weber (Natalya); R.H. Yolken (Robert); B.W.J.H. Penninx (Brenda W.J.H.); S. Bahn (Sabine)

    2015-01-01

    markdownabstract_Background:_ Bipolar disorder (BD) is a costly, devastating and life shortening mental disorder that is often misdiagnosed, especially on initial presentation. Misdiagnosis frequently results in ineffective treatment. We investigated the utility of a biomarker panel as a diagnostic

  2. Model-based Diagnostics for Propellant Loading Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are neces- sary to quickly identify when a fault occurs, so that...

  3. Conceptual fusion reactor designs based on the laser heat solenoid

    International Nuclear Information System (INIS)

    Steinhauer, L.C.

    1976-01-01

    The feasibility of the laser heated solenoid (LHS) as an approach to fusion and fusion-fission commercial power generation has been examined. The LHS concept is based on magnetic confinement of a long slender plasma column which is partly heated by the axially directed beam from a powerful long wavelength laser. As a pure fusion concept, the LHS configurations studied so far are characterized by fairly difficult engineering constraints, particularly on the magnet, a large laser, and a marginally acceptable system energy balance. As a fusion-fission system, however, the LHS is capable of a very attractive energy balance, has much more relaxed engineering constraints, requires a relatively modest laser, and as such holds great potential as a power generator and fissile fuel breeding scheme

  4. Numerical Model based Reliability Estimation of Selective Laser Melting Process

    DEFF Research Database (Denmark)

    Mohanty, Sankhya; Hattel, Jesper Henri

    2014-01-01

    Selective laser melting is developing into a standard manufacturing technology with applications in various sectors. However, the process is still far from being at par with conventional processes such as welding and casting, the primary reason of which is the unreliability of the process. While...... of the selective laser melting process. A validated 3D finite-volume alternating-direction-implicit numerical technique is used to model the selective laser melting process, and is calibrated against results from single track formation experiments. Correlation coefficients are determined for process input...... parameters such as laser power, speed, beam profile, etc. Subsequently, uncertainties in the processing parameters are utilized to predict a range for the various outputs, using a Monte Carlo method based uncertainty analysis methodology, and the reliability of the process is established....

  5. Development of genomic based diagnostics in various application domains

    DEFF Research Database (Denmark)

    Szallasi, Zoltan Imre

    2017-01-01

    We will review the revolution brought about by low cost next generation sequencing in a wide array of diagnostic and industrial applications with a special emphasis on computational requirements and big data challenges.......We will review the revolution brought about by low cost next generation sequencing in a wide array of diagnostic and industrial applications with a special emphasis on computational requirements and big data challenges....

  6. Fast infectious diseases diagnostics based on microfluidic biochip system

    Directory of Open Access Journals (Sweden)

    Qin Huang

    2017-03-01

    Full Text Available Molecular diagnostics is one of the most important tools currently in use for clinical pathogen detection due to its high sensitivity, specificity, and low consume of sample and reagent is keyword to low cost molecular diagnostics. In this paper, a sensitive DNA isothermal amplification method for fast clinical infectious diseases diagnostics at aM concentrations of DNA was developed using a polycarbonate (PC microfluidic chip. A portable confocal optical fluorescence detector was specifically developed for the microfluidic chip that was capable of highly sensitive real-time detection of amplified products for sequence-specific molecular identification near the optical diffraction limit with low background. The molecular diagnostics of Listeria monocytogenes with nucleic acid extracted from stool samples was performed at a minimum DNA template concentration of 3.65aM, and a detection limit of less than five copies of genomic DNA. Contrast to the general polymerase chain reaction (PCR at eppendorf (EP tube, the detection time in our developed method was reduced from 1.5h to 45min for multi-target parallel detection, the consume of sample and reagent was dropped from 25μL to 1.45μL. This novel microfluidic chip system and method can be used to develop a micro total analysis system as a clinically relevant pathogen molecular diagnostics method via the amplification of targets, with potential applications in biotechnology, medicine, and clinical molecular diagnostics.

  7. IR and FIR laser polarimetry as a diagnostic tool in high-. beta. and Tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, D; Machida, M; Scalabrin, A

    1986-03-01

    The change of the polarization state of an electromagnetic wave (EMW) propagating across a magnetized plasma may be used to determine plasma parameters. In a plasma machine of the Tokamak type, the Faraday rotation of the EMW allows for the determination of the product of the plasma electronic density by the poloidal magnetic field. A novel optical configuration which permits simultaneous measurements of these two parameters without the use of an auxiliary interferometric set up is proposed. By choosing appropriate laser wave length this method can be used in Tokamaks (lambda >= 1mm) and also in theta-pinch plasmas (lambda approx. 10..mu..m). The application of these results is discussed to plasma machines now in operation in Brazil, like the Tokamak/USP and theta-pinch/UNICAMP, using lasers developed at UNICAMP.

  8. Time-resolved x-ray line diagnostics of laser-produced plasmas

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Kilkenny, J.D.; Lee, R.W.

    1982-11-01

    We have examined the underdense plasma conditions of laser irradiated disks using K x-rays from highly ionized ions. A 900 ps laser pulse of 0.532 μm light is used to irradiate various Z disks which have been doped with low concentrations of tracer materials. The tracers, whose Z's range from 13 to 22, are chosen so that their K x-ray spectrum is sensitive to typical underdense plasma temperatures and densities. Spectra are measured using a time-resolved crystal spectrograph recording the time history of the x-ray spectrum. A spatially-resolved, time-integrated crystal spectrograph also monitors the x-ray lines. Large differences in Al spectra are observed when the host plasms is changed from SiO 2 to PbO or In. Spectra will be presented along with preliminary analysis of the data

  9. Using self-generated harmonics as a diagnostic of high intensity laser-produced plasmas

    International Nuclear Information System (INIS)

    Krushelnick, K; Watts, I; Tatarakis, M; Gopal, A; Wagner, U; Beg, F N; Clark, E L; Clarke, R J; Dangor, A E; Norreys, P A; Wei, M S; Zepf, M

    2002-01-01

    The interaction of high intensity laser pulses (up to I∼10 20 W cm -2 ) with plasmas can generate very high order harmonics of the laser frequency (up to the 75th order have been observed). Measurements of the properties of these harmonics can provide important insights into the plasma conditions which exist during such interactions. For example, observations of the spectrum of the harmonic emission can provide information of the dynamics of the critical surface as well as information on relativistic non-linear optical effects in the plasma. However, most importantly, observations of the polarization properties of the harmonics can provide a method to measure the ultra-strong magnetic fields (greater than 350 MG) which can be generated during these interactions. It is likely that such techniques can be scaled to provide a significant amount of information from experiments at even higher intensities

  10. Role of diagnostic testing in identifying and resolving dimensional-stability problems in electroplated laser mirrors

    International Nuclear Information System (INIS)

    Cutler, R.L.; Hogan, B.

    1982-01-01

    The metal mirrors which are the subject of this discussion are to be used in the Antares inertial fusion laser system. Antares is a high-power (40 TW), high-energy (35 to 40 kJ), pulsed CO 2 laser system for the investigation of inertial confinement fusion. The system contains more than four hundred small and large diamond-turned and conventionally polished mirrors. The largest mirrors are trapezoidal in shape with the longest dimension being 16 to 18 inches. The substrates are type 2124 aluminum for most large mirrors, and aluminum bronze, oxygen-free copper or a copper-zirconium alloy for most of the smaller mirrors. The optical surface is electro-deposited copper 20 to 40 mils thick. After nondestructive testing and rough machining, the electroplated surface is single-point diamond machined or conventionally polished

  11. Time-resolved x-ray line diagnostics of laser-produced plasmas

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Kilkenny, J.D.; Lee, R.W.

    1982-01-01

    We have examined the underdense plasma conditions of laser irradiated disks using K x-rays from highly ionized ions. A 900 ps laser pulse of 0.532 μm light is used to irradiate various Z disks which have been doped with low concentrations of tracer materials. The tracers whose Z's range from 13 to 22 are chosen so that their K x-ray spectrum is sensitive to typical underdense plasma temperatures and densities. Spectra are measured using a time-resolved crystal spectrograph recording the time history of the x-ray spectrum. A spatially-resolved, time-integrated crystal spectrograph also monitors the x-ray lines. Large differences in Al spectra are observed when the host plasma is changed from SiO 2 to PbO or In. Spectra will be presented along with preliminary analysis of the data

  12. Application of diamond window for infrared laser diagnostics in a tokamak device

    International Nuclear Information System (INIS)

    Kawano, Yasunori; Chiba, Shinichi; Inoue, Akira

    2004-01-01

    Chemical vapor deposited diamond disks have been successfully applied as the vacuum windows for infrared CO 2 laser interferometry and polarimetry used in electron density measurement in the JT-60U tokamak. In comparison with the conventional zinc-selenide windows, the Faraday rotation component of diamond windows was negligible. This results in an improvement of the Faraday rotation measurement of tokamak plasma by polarimetry

  13. Preliminary studies on fast particle diagnostics for the future fs-laser facility at PALS

    Czech Academy of Sciences Publication Activity Database

    Margarone, Daniele; Krása, Josef; Láska, Leoš; Velyhan, Andriy; Mocek, Tomáš; Torrisi, L.; Ando, L.; Gammino, S.; Prokůpek, J.; Krouský, Eduard; Pfeifer, Miroslav; Ullschmied, Jiří; Rus, Bedřich

    2010-01-01

    Roč. 165, 6-10 (2010), s. 419-428 ISSN 1042-0150 R&D Projects: GA AV ČR IAA100100715 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : fs-laser plasma * electron streams * ion streams * electron spectrometer * ion collectors Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.660, year: 2010

  14. High-intensity laser for Ta and Ag implantation into different substrates for plasma diagnostics

    Czech Academy of Sciences Publication Activity Database

    Cutroneo, Mariapompea; Macková, Anna; Malinský, Petr; Matoušek, J.; Torrisi, L.; Ullschmied, Jiří

    2015-01-01

    Roč. 354, JUL (2015), s. 56-59 ISSN 0168-583X R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk LM2011019 Institutional support: RVO:61389005 ; RVO:68378271 Keywords : multi-energy implantation * laser-produced plasma * RBS analysis Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders; BL - Plasma and Gas Discharge Physics (FZU-D) Impact factor: 1.389, year: 2015

  15. Laser-based direct-write techniques for cell printing

    Energy Technology Data Exchange (ETDEWEB)

    Schiele, Nathan R; Corr, David T [Biomedical Engineering Department, Rensselaer Polytechnic Institute, Troy, NY (United States); Huang Yong [Department of Mechanical Engineering, Clemson University, Clemson, SC (United States); Raof, Nurazhani Abdul; Xie Yubing [College of Nanoscale Science and Engineering, University at Albany, SUNY, Albany, NY (United States); Chrisey, Douglas B, E-mail: schien@rpi.ed, E-mail: chrisd@rpi.ed [Material Science and Engineering Department, Rensselaer Polytechnic Institute, Troy, NY (United States)

    2010-09-15

    Fabrication of cellular constructs with spatial control of cell location ({+-}5 {mu}m) is essential to the advancement of a wide range of applications including tissue engineering, stem cell and cancer research. Precise cell placement, especially of multiple cell types in co- or multi-cultures and in three dimensions, can enable research possibilities otherwise impossible, such as the cell-by-cell assembly of complex cellular constructs. Laser-based direct writing, a printing technique first utilized in electronics applications, has been adapted to transfer living cells and other biological materials (e.g., enzymes, proteins and bioceramics). Many different cell types have been printed using laser-based direct writing, and this technique offers significant improvements when compared to conventional cell patterning techniques. The predominance of work to date has not been in application of the technique, but rather focused on demonstrating the ability of direct writing to pattern living cells, in a spatially precise manner, while maintaining cellular viability. This paper reviews laser-based additive direct-write techniques for cell printing, and the various cell types successfully laser direct-written that have applications in tissue engineering, stem cell and cancer research are highlighted. A particular focus is paid to process dynamics modeling and process-induced cell injury during laser-based cell direct writing. (topical review)

  16. Iterative Decoding for an Optical CDMA based Laser communication System

    International Nuclear Information System (INIS)

    Kim, Jin Young; Kim, Eun Cheol; Cha, Jae Sang

    2008-01-01

    An optical CDMA(code division multiple access)based Laser communication system has attracted much attention since it requires minimal optical Laser signal processing and it is virtually delay free, while from the theoretical point of view, its performance depends on the auto and cross correlation properties of employed sequences. Various kinds of channel coding schemes for optical CDMA based Laser communication systems have been proposed and analyzed to compensate nonideal channel and receiver conditions in impaired photon channels. In this paper, we propose and analyze an iterative decoding of optical CDMA based Laser communication signals for both shot noise limited and thermal noise limited systems. It is assumed that optical channel is an intensity modulated (IM)channel and direct detection scheme is employed to detect the received optical signal. The performance is evaluated in terms of bit error probability and throughput. It is demonstrated that the BER and throughput performance is substantially improved with interleaver length for a fixed code rate and with alphabet size of PPM (pulse position modulation). Also, the BER and throughput performance is significantly enhanced with the number of iterations for decoding process. The results in this paper can be applied to the optical CDMA based Laser communication network with multiple access applications

  17. Iterative Decoding for an Optical CDMA based Laser communication System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Young; Kim, Eun Cheol [Kwangwoon Univ., Seoul (Korea, Republic of); Cha, Jae Sang [Seoul National Univ. of Technology, Seoul (Korea, Republic of)

    2008-11-15

    An optical CDMA(code division multiple access)based Laser communication system has attracted much attention since it requires minimal optical Laser signal processing and it is virtually delay free, while from the theoretical point of view, its performance depends on the auto and cross correlation properties of employed sequences. Various kinds of channel coding schemes for optical CDMA based Laser communication systems have been proposed and analyzed to compensate nonideal channel and receiver conditions in impaired photon channels. In this paper, we propose and analyze an iterative decoding of optical CDMA based Laser communication signals for both shot noise limited and thermal noise limited systems. It is assumed that optical channel is an intensity modulated (IM)channel and direct detection scheme is employed to detect the received optical signal. The performance is evaluated in terms of bit error probability and throughput. It is demonstrated that the BER and throughput performance is substantially improved with interleaver length for a fixed code rate and with alphabet size of PPM (pulse position modulation). Also, the BER and throughput performance is significantly enhanced with the number of iterations for decoding process. The results in this paper can be applied to the optical CDMA based Laser communication network with multiple access applications.

  18. Laser-based direct-write techniques for cell printing

    International Nuclear Information System (INIS)

    Schiele, Nathan R; Corr, David T; Huang Yong; Raof, Nurazhani Abdul; Xie Yubing; Chrisey, Douglas B

    2010-01-01

    Fabrication of cellular constructs with spatial control of cell location (±5 μm) is essential to the advancement of a wide range of applications including tissue engineering, stem cell and cancer research. Precise cell placement, especially of multiple cell types in co- or multi-cultures and in three dimensions, can enable research possibilities otherwise impossible, such as the cell-by-cell assembly of complex cellular constructs. Laser-based direct writing, a printing technique first utilized in electronics applications, has been adapted to transfer living cells and other biological materials (e.g., enzymes, proteins and bioceramics). Many different cell types have been printed using laser-based direct writing, and this technique offers significant improvements when compared to conventional cell patterning techniques. The predominance of work to date has not been in application of the technique, but rather focused on demonstrating the ability of direct writing to pattern living cells, in a spatially precise manner, while maintaining cellular viability. This paper reviews laser-based additive direct-write techniques for cell printing, and the various cell types successfully laser direct-written that have applications in tissue engineering, stem cell and cancer research are highlighted. A particular focus is paid to process dynamics modeling and process-induced cell injury during laser-based cell direct writing. (topical review)

  19. Electronegative plasma diagnostic by laser photo-detachment combined with negatively biased Langmuir probe

    Science.gov (United States)

    Oudini, N.; Sirse, N.; Taccogna, F.; Ellingboe, A. R.; Bendib, A.

    2018-05-01

    We propose a new technique for diagnosing negative ion properties using Langmuir probe assisted pulsed laser photo-detachment. While the classical technique uses a laser pulse to convert negative ions into electron-atom pairs and a positively biased Langmuir probe tracking the change of electron saturation current, the proposed method uses a negatively biased Langmuir probe to track the temporal evolution of positive ion current. The negative bias aims to avoid the parasitic electron current inherent to probe tip surface ablation. In this work, we show through analytical and numerical approaches that, by knowing electron temperature and performing photo-detachment at two different laser wavelengths, it is possible to deduce plasma electronegativity (ratio of negative ion to electron densities) α, and anisothermicity (ratio of electron to negative ion temperatures) γ-. We present an analytical model that links the change in the collected positive ion current to plasma electronegativity and anisothermicity. Particle-In-Cell simulation is used as a numerical experiment covering a wide range of α and γ- to test the new analysis technique. The new technique is sensitive to α in the range 0.5 1.

  20. Control of Reproduced Colour Using Laser Based Tristimulus Colorimetry

    OpenAIRE

    Oulton, David

    1999-01-01

    Tristimulus colorimetry based laser line reflectance measurement is proposed and exemplified by the construction and testing of a prototype abridged spectrometer.The intent is to enable rugged on-line colour measurement and improve on the instrument to instrument variability that is characteristic of filter based spectrometry

  1. Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Lanzalone, G., E-mail: Gaetano.Lanzalone@ct.infn.it [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy); Università degli Studi di Enna “Kore,” Via delle Olimpiadi, 94100 Enna (Italy); Altana, C. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università degli Studi di Catania, Via S. Sofia 64, 95123 Catania (Italy); Mascali, D.; Tudisco, S. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy); Muoio, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Messina, Viale F.S. D’Alcontres 31, 98166 Messina (Italy); Malferrari, L.; Odorici, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); Malandrino, G. [Dipartimento di Scienze Chimiche and INSTM UdR, Università degli Studi di Catania, Catania (Italy)

    2016-02-15

    An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al{sub 2}O{sub 3} of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasma plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the “optical range” signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.

  2. Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited)

    Science.gov (United States)

    Lanzalone, G.; Altana, C.; Mascali, D.; Muoio, A.; Malferrari, L.; Odorici, F.; Malandrino, G.; Tudisco, S.

    2016-02-01

    An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al2O3 of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasma plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the "optical range" signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.

  3. Self-referencing Mach-Zehnder interferometer as a laser system diagnostic: Active and adaptive optical systems

    International Nuclear Information System (INIS)

    Feldman, M.; Mockler, D.J.; English, R.E. Jr.; Byrd, J.L.; Salmon, J.T.

    1991-01-01

    We are incorporating a novel self-referencing Mach-Zehnder interferometer into a large scale laser system as a real time, interactive diagnostic tool for wavefront measurement. The instrument is capable of absolute wavefront measurements accurate to better than λ/10 pv over a wavelength range > 300 nm without readjustment of the optical components. This performance is achieved through the design of both refractive optics and catadioptric collimator to achromatize the Mach-Zehnder reference arm. Other features include polarization insensitivity through the use of low angles of incidence on all beamsplitters as well as an equal path length configuration that allows measurement of either broad-band or closely spaced laser-line sources. Instrument accuracy is periodically monitored in place by means of a thermally and mechanically stable wavefront reference source that is calibrated off-line with a phase conjugate interferometer. Video interferograms are analyzed using Fourier transform techniques on a computer that includes dedicated array processor. Computer and video networks maintain distributed interferometers under the control of a single analysis computer with multiple user access. 7 refs., 11 figs

  4. Diagnostic technique for measuring fusion reaction rate for inertial confinement fusion experiments at Shen Guang-III prototype laser facility

    International Nuclear Information System (INIS)

    Wang Feng; Peng Xiao-Shi; Liu Shen-Ye; Xu Tao; Kang Dong-Guo

    2013-01-01

    A study is conducted using a two-dimensional simulation program (Lared-s) with the goal of developing a technique to evaluate the effect of Rayleigh-Taylor growth in a neutron fusion reaction region. Two peaks of fusion reaction rate are simulated by using a two-dimensional simulation program (Lared-s) and confirmed by the experimental results. A neutron temporal diagnostic (NTD) system is developed with a high temporal resolution of ∼ 30 ps at the Shen Guang-III (SG-III) prototype laser facility in China, to measure the fusion reaction rate history. With the shape of neutron reaction rate curve and the spherical harmonic function in this paper, the degree of Rayleigh-Taylor growth and the main source of the neutron yield in our experiment can be estimated qualitatively. This technique, including the diagnostic system and the simulation program, may provide important information for obtaining a higher neutron yield in implosion experiments of inertial confinement fusion

  5. Rapid analysis of steels using laser-based techniques

    International Nuclear Information System (INIS)

    Cremers, D.A.; Archuleta, F.L.; Dilworth, H.C.

    1985-01-01

    Based on the data obtained by this study, we conclude that laser-based techniques can be used to provide at least semi-quantitative information about the elemental composition of molten steel. Of the two techniques investigated here, the Sample-Only method appears preferable to the LIBS (laser-induced breakdown spectroscopy) method because of its superior analytical performance. In addition, the Sample-Only method would probably be easier to incorporate into a steel plant environment. However, before either technique can be applied to steel monitoring, additional research is needed

  6. Surface alloying of nickel based superalloys by laser

    International Nuclear Information System (INIS)

    Rodriguez, G.P.; Garcia, I.; Damborenea, J.J. de

    1998-01-01

    Ni based superalloys present a high oxidation resistance at high temperature as well as good mechanical properties. But new technology developments force to research in this materials to improve their properties at high temperature. In this work, two Ni based superalloys (Nimonic 80A and Inconel 600) were surface alloyed with aluminium using a high power laser. SEM and EDX were used to study the microstructure of the obtained coatings. Alloyed specimens were tested at 1.273 K between 24 and 250 h. Results showed the generation of a protective and continuous coating of alumina on the laser treated specimens surface that can improve oxidation resistance. (Author) 8 refs

  7. Experimental demonstration of a Fano laser based on photonic crystals

    DEFF Research Database (Denmark)

    Yu, Yi; Semenova, Elizaveta; Yvind, Kresten

    2017-01-01

    Conventional semiconductor laser mirrors are based on Fresnel reflection [1], Bragg reflection [2, 3] or total internal reflection [4]. Here we demonstrate a new laser concept using photonic crystals (PhC), with a mirror based on Fano interference between a waveguide continuum and a discrete...... resonance of a nanocavity [5]. We show that the very narrowband feature of the Fano resonance [6] can lead to single mode lasing. In addition, when combined with optical nonlinearity, the highly dispersive feature of the Fano resonance can promote self-pulsations at gigahertz frequencies [7], which...

  8. Broadband pulsed difference frequency generation laser source centered 3326 nm based on ring fiber lasers

    Science.gov (United States)

    Chen, Guangwei; Li, Wenlei

    2018-03-01

    A broadband pulsed mid-infrared difference frequency generation (DFG) laser source based on MgO-doped congruent LiNbO3 bulk is experimentally demonstrated, which employs a homemade pulsed ytterbium-doped ring fiber laser and a continuous wave erbium-doped ring fiber laser to act as seed sources. The experimental results indicate that the perfect phase match crystal temperature is about 74.5∘C. The maximum spectrum bandwidth of idler is about 60 nm with suitable polarization states of fundamental lights. The central wavelength of idlers varies from 3293 nm to 3333 nm over the crystal temperature ranges of 70.4-76∘C. A jump of central wavelength exists around crystal temperature of 72∘C with variation of about 30 nm. The conversion efficiency of DFG can be tuned with the crystal temperature and polarization states of fundamental lights.

  9. Optimal Combinations of Diagnostic Tests Based on AUC.

    Science.gov (United States)

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  10. Bayesian based Diagnostic Model for Condition based Maintenance of Offshore Wind Farms

    DEFF Research Database (Denmark)

    Asgarpour, Masoud; Sørensen, John Dalsgaard

    2018-01-01

    Operation and maintenance costs are a major contributor to the Levelized Cost of Energy for electricity produced by offshore wind and can be significantly reduced if existing corrective actions are performed as efficiently as possible and if future corrective actions are avoided by performing...... sufficient preventive actions. This paper presents an applied and generic diagnostic model for fault detection and condition based maintenance of offshore wind components. The diagnostic model is based on two probabilistic matrices; first, a confidence matrix, representing the probability of detection using...... for a wind turbine component based on vibration, temperature, and oil particle fault detection methods. The last part of the paper will have a discussion of the case study results and present conclusions....

  11. Multi-parameter sensor based on random fiber lasers

    Directory of Open Access Journals (Sweden)

    Yanping Xu

    2016-09-01

    Full Text Available We demonstrate a concept of utilizing random fiber lasers to achieve multi-parameter sensing. The proposed random fiber ring laser consists of an erbium-doped fiber as the gain medium and a random fiber grating as the feedback. The random feedback is effectively realized by a large number of reflections from around 50000 femtosecond laser induced refractive index modulation regions over a 10cm standard single mode fiber. Numerous polarization-dependent spectral filters are formed and superimposed to provide multiple lasing lines with high signal-to-noise ratio up to 40dB, which gives an access for a high-fidelity multi-parameter sensing scheme. The number of sensing parameters can be controlled by the number of the lasing lines via input polarizations and wavelength shifts of each peak can be explored for the simultaneous multi-parameter sensing with one sensing probe. In addition, the random grating induced coupling between core and cladding modes can be potentially used for liquid medical sample sensing in medical diagnostics, biology and remote sensing in hostile environments.

  12. A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

    International Nuclear Information System (INIS)

    Metzkes, J.; Kraft, S. D.; Sobiella, M.; Stiller, N.; Zeil, K.; Schramm, U.; Karsch, L.; Schürer, M.; Pawelke, J.; Richter, C.

    2012-01-01

    In recent years, a new generation of high repetition rate (∼10 Hz), high power (∼100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ∼1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

  13. A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra.

    Science.gov (United States)

    Metzkes, J; Karsch, L; Kraft, S D; Pawelke, J; Richter, C; Schürer, M; Sobiella, M; Stiller, N; Zeil, K; Schramm, U

    2012-12-01

    In recent years, a new generation of high repetition rate (~10 Hz), high power (~100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ~1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

  14. Intraoral fiber optic-based diagnostic for periodontal disease

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P W; Gutierrez, D M; Everett, M J; Brown, S B; Langry, K C; Colston, B W; Roe, J N

    2000-01-21

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic sensor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research tool.

  15. Intraoral fiber-optic-based diagnostic for periodontal disease

    Science.gov (United States)

    Colston, Bill W., Jr.; Gutierrez, Dora M.; Everett, Matthew J.; Brown, Steve B.; Langry, Kevin C.; Cox, Weldon R.; Johnson, Paul W.; Roe, Jeffrey N.

    2000-05-01

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic senor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research too.

  16. Scavenging processes in high speed two-stroke engines studied with laser diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ekenberg, M.

    1998-12-31

    The major problem with the carburetted two-stroke engine is the short-circuiting of fuel that occurs during the scavenging phase. This leads to large emissions of unburned hydrocarbons. The object of this thesis has been to map the flow behaviour in the cylinder during the scavenging phase, and to detect differences between different cylinder designs. The measurement techniques used has been Laser Doppler Velocimetry (LDV), Laser Induced Fluorescence (LIF) and Laser Sheet Droplet Illumination (LSDI). Of these measurement methods, LDV and LSDI has been used inside the cylinder. LIF was used outside the exhaust port. All measurements were performed in engines running at their rated speeds, 9000 rpm for three of the designs and 5800 rpm for one design. All engines were run at full load with combustion. The LDV measurements inside the cylinder show that cylinders with cup handle transfer channels have a flow pattern inside the cylinder that gives less short-circuiting, and hence less emissions of hydrocarbons, than the cylinder with open transfer channels has. The LIF measurements outside the exhaust port show that the HC emissions that are caused by short-circuiting comes earlier in the scavenging phase for the cylinder with open transfer channels than is the case for the cylinders with cup handle transfer channels. The LSDI measurements in the cylinder give the transfer channel flow angle, for the cylinders with cup handle transfer channels. For the cylinder with open transfer channels, the results are not as useful; fuel droplet vaporization close to the exhaust port ruins the results 35 refs, 43 figs

  17. Multiscale modeling of beryllium: quantum mechanics and laser-driven shock experiments using novel diagnostics

    International Nuclear Information System (INIS)

    Swift, D.C.; Paisley, Dennis L.; Kyrala, George A.; Hauer, Allan

    2002-01-01

    Ab initio quantum mechanics was used to construct a thermodynamically complete and rigorous equation of state for beryllium in the hexagonal and body-centred cubic structures, and to predict elastic constants as a function of compression. The equation of state agreed well with Hugoniot data and previously-published equations of state, but the temperatures were significantly different. The hexagonal/bcc phase boundary agreed reasonably well with published data, suggesting that the temperatures in our new equation of state were accurate. Shock waves were induced in single crystals and polycrystalline foils of beryllium, by direct illumination using the TRIDENT laser at Los Alamos. The velocity history at the surface of the sample was measured using a line-imaging VISAR, and transient X-ray diffraction (TXD) records were obtained with a plasma backlighter and X-ray streak cameras. The VISAR records exhibited elastic precursors, plastic waves, phase changes and spall. Dual TXD records were taken, in Bragg and Laue orientations. The Bragg lines moved in response to compression in the uniaxial direction. Because direct laser drive was used, the results had to be interpreted with the aid of radiation hydrodynamics simulations to predict the loading history for each laser pulse. In the experiments where there was evidence of polymorphism in the VISAR record, additional lines appeared in the Bragg and Laue records. The corresponding pressures were consistent with the phase boundary predicted by the quantum mechanical equation of state for beryllium. A model of the response of a single crystal of beryllium to shock loading is being developed using these new theoretical and experimental results. This model will be used in meso-scale studies of the response of the microstructure, allowing us to develop a more accurate representation of the behaviour of polycrystalline beryllium.

  18. Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, A. P., E-mail: APKuznetsov@mephi.ru; Alexandrova, A. S. [National Research Nuclear University MEPhI (Russian Federation); Buzhinsky, O. I. [State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research (Russian Federation); Gubskiy, K. L.; Kazieva, T. V.; Savchenkov, A. V. [National Research Nuclear University MEPhI (Russian Federation); Tugarinov, S. N. [State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research (Russian Federation)

    2015-12-15

    The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10{sup 7} W/cm{sup 2}. The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant.

  19. Feasibility of Optical Transition Radiation Imaging for Laser-driven Plasma Accelerator Electron-Beam Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Rule, D. W. [Unlisted, US, MD; Downer, M. C. [Texas U.

    2017-10-09

    We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/γ and beam sizes to be determined at the micron level. Analytical modeling results indicate the feasibility of using these OTR techniques for the LPA applications.

  20. Evaporation as a diagnostic test for hydrodynamic cooling of laser-ablated clusters

    International Nuclear Information System (INIS)

    Klots, C.E.

    1991-01-01

    The properties of materials laser-ablated from a surface are of considerable interest. The interrogation of these properties inevitably occurs at a point some distance from the surface. One might then ask what processes have occurred in the intervening path length. Immediately, for example, one wonders whether the material was released as such from the surface or was formed as a result of collisions at a distant point. Similarly, one might ask if an observed ''temperature'' of the materials is characteristic of the ablation process of of subsequent events. We will indicate here how measurements of metastable evaporation rates can provide clues which are pertinent to these questions. 7 refs

  1. Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

    International Nuclear Information System (INIS)

    Kuznetsov, A. P.; Alexandrova, A. S.; Buzhinsky, O. I.; Gubskiy, K. L.; Kazieva, T. V.; Savchenkov, A. V.; Tugarinov, S. N.

    2015-01-01

    The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10 7 W/cm 2 . The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant

  2. Laser photothermal diagnostics of genuine and counterfeit British and United States banknotes

    Science.gov (United States)

    Othonos, Andreas; Mandelis, Andreas; Nestoros, Marios; Christofides, Constantinos

    1997-02-01

    Laser-induced, frequency-scanned IR photothermal radiometry was used to investigate the thermophysical properties of the paper on which several genuine and counterfeit British (10 pounds) and U.S. ($DOL50, $DOL100) currency bills were printed. The radiometric photothermal amplitudes and phases were further compared with a theoretical model, which yielded simultaneous quantitative measurements of the thermal diffusivities and conductivities of the bills. Both statistical and single-specimen results demonstrated the excellent thermophysical resolution of the technique with prospects for its use in the nonintrusive, on-line identification of counterfeit banknotes.

  3. Laser fluorescent diagnostics of a plasma of combustion products with an alkali additive

    International Nuclear Information System (INIS)

    Mokhov, A.V.; Nefedov, A.P.

    1993-01-01

    Methods of laser fluorescent determination of sodium atom and hydroxyl molecule (impurity fire component) concentration are described. A method of wide-band detection is presented in detail. A monochromator, its transmission band allowing one to detect all rotational lines of hydroxyl electron-vibrational transition, is used as wide-bond filter. High efficiency of using the methods described in studying the combustion chemistry, kinetics of sodium atom compound production in combustion product plasma and pre-electrode processes is demonstrated. 95 refs., 12 figs., 4 tabs

  4. Plasma diagnostics: Detection of laser scattering: Final report, September 1, 1978 to August 31, 1982

    International Nuclear Information System (INIS)

    Dutta, J.M.; Jones, C.R.

    1985-01-01

    Submillimeter (SMM) radiation is the optimum radiation to use in studying some parameters of plasmas produced in Tokamak machines. The ultimate objective has been in constructing a low-noise SMM receiver suitable for application to the diagnosis of Tokamak plasmas. In this connection, a compact, stable SMM laser has been designed and constructed, and its performance as a local oscillator in the heterodyne detection has been tested. The performance of Schottky diodes as mixer elements has been evaluated by utilizing them in a quasi-optical modulation for the heterodyne generation of tunable sidebands

  5. Photoacoustic CO2 sensor based on a DFB diode laser at 2.7 μm

    Science.gov (United States)

    Wolff, M.; Germer, M.; Groninga, H. G.; Harde, H.

    2008-01-01

    We present a new detection scheme for carbon dioxide (CO{2}) based on a custom-made room temperature distributed feedback (DFB) diode laser at 2.7 μm, currently representing one of the lasers with the highest emission wavelength of its kind. The detector's especially compact and simple set-up is based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. The sensor enables a very high detection sensitivity for CO{2} in the ppb range. Furthermore, the carefully selected spectral region as well as the narrow bandwidth and wide tunability of the single-mode laser ensure an excellent selectivity. Even measurements of different CO{2} isotopes can be easily performed. This enables applications in industrial sensing and medical diagnostics (e.g. 13C-breath tests).

  6. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  7. Molecular diagnostics based on clustering dynamics of magnetic nanobeads

    DEFF Research Database (Denmark)

    Donolato, Marco; Bejhed, Rebecca S.; de la Torre, Teresa Zardán Gómez

    2014-01-01

    transmission modulation caused by the AC magnetic field-stimulated reversible formation and disruption of elongated MNB supra-structures during a cycle of the uniaxial applied magnetic field. As a specific clinically relevant diagnostic case, we detect DNA coils formed via padlock probe recognition...

  8. Diagnostics of femoral head status in humans using laser spectroscopy - In vitro studies.

    Science.gov (United States)

    Lin, Huiying; Li, Wansha; Zhang, Hao; Chen, Peng; Chen, Delong; He, Wei; Svanberg, Sune; Svanberg, Katarina

    2017-10-01

    Osteonecrosis of the femoral head (ONFH), a recalcitrant and disabling disease, is caused by inadequate or fully disrupted blood supply to the affected segment of the subchondral bone. Theoretically, there will develop gas-filled pores during the bone decay process due to lacking blood supply. Unfortunately, the relationship between the gas-filled pores and ONFH is still unclear. Here, we have introduced diode laser absorption spectroscopy to detect oxygen and water vapor signals in the femoral heads from hip replacement in 19 patients. Five samples are affected by osteoarthritis (OA) and the others are related to ONFH. Oxygen and water vapor signals could be obtained, demonstrating the presence of gas-filled pores in both the OA and ONFH groups while the measurement results showed no significant difference. A study of gas exchange was also performed on one excised bone sample to study how these gas pores communicate with the ambient air. The results suggested that the obtained oxygen signals inside the bone samples originate from the invasion of ambient air, which is not expected in vivo. In conclusion, the ability to detect the gas signal of laser absorption spectroscopy shows the potential for the medical application of assessing the human femoral head in vivo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. High-intensity laser for Ta and Ag implantation into different substrates for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Cutroneo, M., E-mail: cutroneo@ujf.cas.cz [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Mackova, A.; Malinsky, P. [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Matousek, J. [Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Torrisi, L. [Department of Physics and Earth Sciences, Messina University, V.le F.S. d’Alcontres 31, 98166 S. Agata, Messina (Italy); Ullschmied, J. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic)

    2015-07-01

    High-intensity lasers generating non-equilibrium plasma, can be employed to accelerate ions in the keV–MeV region, useful for many applications. In the present work, we performed study of ion implantation into different substrates by using a high-intensity laser at the PALS laboratory in Prague. Multi-energy ions generated by plasma from Ta and Ag targets were implanted into polyethylene and metallic substrates (Al, Ti) at energies of tens of keV per charge state. The ion emission was monitored online using time-of-flight detectors and electromagnetic deflection systems. Rutherford Backscattering Spectrometry (RBS) was used to characterise the elemental composition in the implanted substrates by ion plasma emission and to provide the implanted ion depth profiling. These last measurements enable offline plasma characterisation and provide information on the useful potentiality of multi-ion species and multi-energy ion implantation into different substrates. XPS analysis gives information on the chemical bonds and their modifications in the first superficial implanted layers. The depth distributions of implanted Ta and Ag ions were compared with the theoretical ones achieved by using the SRIM-2012 simulation code.

  10. Near-infrared diode laser absorption diagnostic for temperature and water vapor in a scramjet combustor

    International Nuclear Information System (INIS)

    Liu, Jonathan T.C.; Rieker, Gregory B.; Jeffries, Jay B.; Gruber, Mark R.; Carter, Campbell D.; Mathur, Tarun; Hanson, Ronald K.

    2005-01-01

    Tunable diode laser absorption measurements of gas temperature and water concentration were made at the exit of a model scramjet combustor fueled on JP-7. Multiplexed, fiber-coupled, near-infrared distributed feedback lasers were used to probe three water vapor absorption features in the 1.34-1.47 μm spectral region (2v1and v1+ v3overtone bands). Ratio thermometry was performed using direct-absorption wavelength scans of isolated features at a 4-kHz repetition rate, as well as 2f wavelength modulation scans at a 2-kHz scan rate. Large signal-to-noise ratios demonstrate the ability of the optimally engineered optical hardware to reject beam steering and vibration noise. Successful measurements were made at full combustion conditions for a variety of fuel/air equivalence ratios and at eight vertical positions in the duct to investigate spatial uniformity. The use of three water vapor absorption features allowed for preliminary estimates of temperature distributions along the line of sight. The improved signal quality afforded by 2f measurements, in the case of weak absorption, demonstrates the utility of a scanned wavelength modulation strategy in such situations

  11. Bayesian Based Diagnostic Model for Condition Based Maintenance of Offshore Wind Farms

    Directory of Open Access Journals (Sweden)

    Masoud Asgarpour

    2018-01-01

    Full Text Available Operation and maintenance costs are a major contributor to the Levelized Cost of Energy for electricity produced by offshore wind and can be significantly reduced if existing corrective actions are performed as efficiently as possible and if future corrective actions are avoided by performing sufficient preventive actions. This paper presents an applied and generic diagnostic model for fault detection and condition based maintenance of offshore wind components. The diagnostic model is based on two probabilistic matrices; first, a confidence matrix, representing the probability of detection using each fault detection method, and second, a diagnosis matrix, representing the individual outcome of each fault detection method. Once the confidence and diagnosis matrices of a component are defined, the individual diagnoses of each fault detection method are combined into a final verdict on the fault state of that component. Furthermore, this paper introduces a Bayesian updating model based on observations collected by inspections to decrease the uncertainty of initial confidence matrix. The framework and implementation of the presented diagnostic model are further explained within a case study for a wind turbine component based on vibration, temperature, and oil particle fault detection methods. The last part of the paper will have a discussion of the case study results and present conclusions.

  12. The design of laser atmosphere transmission characteristic measurement system based on virtual instrument

    Science.gov (United States)

    Zhang, Laixian; Sun, Huayan; Xu, Jiawen

    2010-10-01

    The laser atmosphere transmission characteristic affects the use of laser in engineering greatly. This paper designed a laser atmosphere transmission characteristic measurement system based on LabVIEW software, a product of NI. The system acquires laser spacial distribution by means of controlling NI image acquisition card and CCD through PCI, controls oscillograph to acquire laser time domain distribution through Ethernet and controls power meter to acquire energy of laser through RS-232. It processes the data acquired and analyses the laser atmosphere transmission characteristic using Matlab, which is powerful in data processing, through software interface. It provided a new way to study the laser atmosphere transmission characteristic.

  13. Comparison of laser-based mitigation of fused silica surface damage using mid- versus far-infrared lasers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S T; Matthews, M J; Elhadj, S; Cooke, D; Guss, G M; Draggoo, V G; Wegner, P J

    2009-12-16

    Laser induced growth of optical damage can limit component lifetime and therefore operating costs of large-aperture fusion-class laser systems. While far-infrared (IR) lasers have been used previously to treat laser damage on fused silica optics and render it benign, little is known about the effectiveness of less-absorbing mid-IR lasers for this purpose. In this study, they quantitatively compare the effectiveness and efficiency of mid-IR (4.6 {micro}m) versus far-IR (10.6 {micro}m) lasers in mitigating damage growth on fused silica surfaces. The non-linear volumetric heating due to mid-IR laser absorption is analyzed by solving the heat equation numerically, taking into account the temperature-dependent absorption coefficient {alpha}(T) at {lambda} = 4.6 {micro}m, while far-IR laser heating is well-described by a linear analytic approximation to the laser-driven temperature rise. In both cases, the predicted results agree well with surface temperature measurements based on infrared radiometry, as well as sub-surface fictive temperature measurements based on confocal Raman microscopy. Damage mitigation efficiency is assessed using a figure of merit (FOM) relating the crack healing depth to laser power required, under minimally-ablative conditions. Based on their FOM, they show that for cracks up to at least 500 {micro}m in depth, mitigation with a 4.6 {micro}m mid-IR laser is more efficient than mitigation with a 10.6 {micro}m far-IR laser. This conclusion is corroborated by direct application of each laser system to the mitigation of pulsed laser-induced damage possessing fractures up to 225 {micro}m in depth.

  14. Centralized computer-based controls of the Nova Laser Facility

    International Nuclear Information System (INIS)

    Krammen, J.

    1985-01-01

    This article introduces the overall architecture of the computer-based Nova Laser Control System and describes its basic components. Use of standard hardware and software components ensures that the system, while specialized and distributed throughout the facility, is adaptable. 9 references, 6 figures

  15. Contextual segment-based classification of airborne laser scanner data

    NARCIS (Netherlands)

    Vosselman, George; Coenen, Maximilian; Rottensteiner, Franz

    2017-01-01

    Classification of point clouds is needed as a first step in the extraction of various types of geo-information from point clouds. We present a new approach to contextual classification of segmented airborne laser scanning data. Potential advantages of segment-based classification are easily offset

  16. Near-infrared Raman spectroscopy using a diode laser and CCD detector for tissue diagnostics

    International Nuclear Information System (INIS)

    Gustafsson, U.

    1993-09-01

    This paper surveys the possibility to observe high-quality NIR Raman spectra of both fluorescent and non-fluorescent samples with the use of a diode laser, a fibre optic sample, a single spectrometer and a charge-coupled device (CCD) detector. A shifted excitation difference technique was implemented for removing the broad-band fluorescence emission from Raman spectra of the highly fluorescent samples. Raman spectra of 1.4-dioxane, toluene, rhodamine 6G, and HITCI in the 640 to 1840 cm -1 spectral region and 1.4-dioxane and toluene in the 400 to 3400 cm -1 spectral region have been recorded. The results open the field of sensitive tissue characterisation and the possibility of optical biopsy in vivo by using NIR Raman spectroscopy with fibre optic sampling, a single spectrometer, and a CCD detector

  17. Diagnostics of Susabi-nori (Porphyra Yezoensis) by Laser-Induced Fluorescence Method

    Science.gov (United States)

    Okamoto, Tamotsu; Nakamura, Yuki; Takahashi, Kunio; Kaneko, Shohei; Shimada, Yuji

    Susabi-nori (Porphyra yezoensis) was diagnosed by means of laser-induced fluorescence (LIF) method. Fluorescence peaks located at approximately 580, 660, 685 and 720 nm were observed in the LIF spectra of Susabi-nori. In the spectrum of the sample infected with the red rot disease, the intensity of 580 nm peak was relatively high as compared with that of the control sample. On the other hand, the intensities of 580 nm and 660 nm peaks drastically decreased by the influence of the chytrid disease. Furthermore, the intensity of the 580 nm peak increased by dipping into fresh water. These results indicate that LIF spectra of Susabi-nori are affected by the diseases and the stress of fresh water and that the diseases and the stress of Susabi-nori can be diagnosed by the LIF method.

  18. Laser diagnostics of atomic hydrogen and oxygen production in rf and microwave plasma discharges

    International Nuclear Information System (INIS)

    Preppernau, B.L.

    1993-01-01

    The research for this thesis involved the application of two-photon allowed laser-induced fluorescence (TALIF) to the study of atomic hydrogen and oxygen production in industrial scale radio-frequency and microwave plasma discharge apparatus. Absolute atomic hydrogen concentration profiles were measured in a Gaseous Electronics Conference Reference Cell installed at Wright-Patterson AFB, Ohio operating with a simple H 2 discharge. Two-dimensional atomic hydrogen concentration profiles were also measured in an ASTEX HPMM microwave plasma diamond deposition reactor during actual diamond growth. In addition absolute atomic oxygen concentrations were measured in the ASTEX system. Particular attention as paid to refining the concentration calibration technique and in determining a correction to account for the collisional quenching of excited state fluorescence in high pressure gases

  19. Laser diagnostics of H- formation in a magnetic multicusp ion source

    International Nuclear Information System (INIS)

    Young, A.T.; Chen, P.; Kunkel, W.B.; Leung, K.N.; Li, C.Y.; Stutzin, G.C.

    1991-05-01

    The populations of ground electronic state atomic hydrogen and ground electronic state, vibrationally-rotationally excited hydrogen molecules in a negative hydrogen ion source discharge have been measured using vacuum ultraviolet (VUV) laser absorption spectroscopy. Vibrational states up to v=8 and rotational levels as high as J=15 have been measured. The measurements have been made under a range of discharge conditions. The complete vibrational population distribution for v=1-8, J=1 has been obtained. The vibrational distribution appears to be thermalized and does not exhibit a ''plateau'' at the higher vibrational levels, in contrast to most models of this system. In contrast, the high rotational states are populated suprathermally. These determinations indicate that rotationally excited molecules may play an important role in the production of H minus in these sources. 5 refs., 5 figs

  20. Diagnostics of ETL TPE-1 plasmas by using a He--Ne laser

    Energy Technology Data Exchange (ETDEWEB)

    Maejima, Y; Sugimoto, H; Tamaru, T [Electrotechnical Lab., Tanashi, Tokyo (Japan). Tanashi Branch

    1975-08-01

    The electron density in the plasma of toroidal screw pinch device TPE-1 of the Electrotechnical Laboratory has been measured with a conventional optical interferometer of He-Ne gas laser, 6,328 A in wavelength. The minimum phase shift detectable is about 1/300 lambda, equivalent to ..integral..nsub(e)dl=1x10/sup 15/cm/sup -2/. Some problems on this measuring system are presented. As the system uses conventional components, it is easy to construct and handle and is useful for determining plasma parameters in confinement experiments. The confinement time of charged particles is measured. As a result it has been found that the particles escape from the plasma mostly in conformity with the classical diffusion.

  1. Integration of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in blood culture diagnostics: a fast and effective approach.

    Science.gov (United States)

    Klein, Sabrina; Zimmermann, Stefan; Köhler, Christine; Mischnik, Alexander; Alle, Werner; Bode, Konrad A

    2012-03-01

    Sepsis is a major cause of mortality in hospitalized patients worldwide, with lethality rates ranging from 30 to 70 %. Sepsis is caused by a variety of different pathogens, and rapid diagnosis is of outstanding importance, as early and adequate antimicrobial therapy correlates with positive clinical outcome. In recent years, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) fingerprinting has become a powerful tool in microbiological diagnostics. The direct identification of micro-organisms in a positive blood culture by MALDI-TOF MS can shorten the diagnostic procedure significantly. Therefore, the aim of the present study was to evaluate whether identification rates could be improved by using the new Sepsityper kit from Bruker Daltonics for direct isolation and identification of bacteria from positive blood cultures by MALDI-TOF MS compared with the use of conventional separator gel columns, and to integrate the MALDI-TOF MS-based identification method into the routine course of blood culture diagnostics in the setting of a microbiological laboratory at a university hospital in Germany. The identification of Gram-negative bacteria by MALDI-TOF MS was significantly better using the Sepsityper kit compared with a separator gel tube-based method (99 and 68 % correct identification, respectively). For Gram-positive bacteria, only 73 % were correctly identified by MALDI-TOF with the Sepsityper kit and 59 % with the separator gel tube assay. A major problem of both methods was the poor identification of Gram-positive grape-like clustered cocci. As differentiation of Staphylococcus aureus from coagulase-negative staphylococci is of clinical importance, a PCR was additionally established that was capable of identifying S. aureus directly from positive blood cultures, thus closing this diagnostic gap. Another benefit of the PCR approach is the possibility of directly detecting the genes responsible for meticillin

  2. A laser printing based approach for printed electronics

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, T.; Hu, M.; Guo, Q.; Zhang, W.; Yang, J., E-mail: jyang@eng.uwo.ca [Department of Mechanical and Materials Engineering, Western University, London N6A 3K7 (Canada); Liu, Y.; Lau, W. [Chengdu Green Energy and Green Manufacturing Technology R& D Center, 355 Tengfei Road, 620107 Chengdu (China); Wang, X. [Department of Mechanical and Materials Engineering, Western University, London N6A 3K7 (Canada); Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2016-03-07

    Here we report a study of printing of electronics using an office use laser printer. The proposed method eliminates those critical disadvantages of solvent-based printing techniques by taking the advantages of electroless deposition and laser printing. The synthesized toner acts as a catalyst for the electroless copper deposition as well as an adhesion-promoting buffer layer between the substrate and deposited copper. The easy metallization of printed patterns and strong metal-substrate adhesion make it an especially effective method for massive production of flexible printed circuits. The proposed process is a high throughput, low cost, efficient, and environmentally benign method for flexible electronics manufacturing.

  3. A laser printing based approach for printed electronics

    International Nuclear Information System (INIS)

    Zhang, T.; Hu, M.; Guo, Q.; Zhang, W.; Yang, J.; Liu, Y.; Lau, W.; Wang, X.

    2016-01-01

    Here we report a study of printing of electronics using an office use laser printer. The proposed method eliminates those critical disadvantages of solvent-based printing techniques by taking the advantages of electroless deposition and laser printing. The synthesized toner acts as a catalyst for the electroless copper deposition as well as an adhesion-promoting buffer layer between the substrate and deposited copper. The easy metallization of printed patterns and strong metal-substrate adhesion make it an especially effective method for massive production of flexible printed circuits. The proposed process is a high throughput, low cost, efficient, and environmentally benign method for flexible electronics manufacturing.

  4. Femtosecond laser fabrication of fiber based optofluidic platform for flow cytometry applications

    Science.gov (United States)

    Serhatlioglu, Murat; Elbuken, Caglar; Ortac, Bulend; Solmaz, Mehmet E.

    2017-02-01

    Miniaturized optofluidic platforms play an important role in bio-analysis, detection and diagnostic applications. The advantages of such miniaturized devices are extremely low sample requirement, low cost development and rapid analysis capabilities. Fused silica is advantageous for optofluidic systems due to properties such as being chemically inert, mechanically stable, and optically transparent to a wide spectrum of light. As a three dimensional manufacturing method, femtosecond laser scanning followed by chemical etching shows great potential to fabricate glass based optofluidic chips. In this study, we demonstrate fabrication of all-fiber based, optofluidic flow cytometer in fused silica glass by femtosecond laser machining. 3D particle focusing was achieved through a straightforward planar chip design with two separately fabricated fused silica glass slides thermally bonded together. Bioparticles in a fluid stream encounter with optical interrogation region specifically designed to allocate 405nm single mode fiber laser source and two multi-mode collection fibers for forward scattering (FSC) and side scattering (SSC) signals detection. Detected signal data collected with oscilloscope and post processed with MATLAB script file. We were able to count number of events over 4000events/sec, and achieve size distribution for 5.95μm monodisperse polystyrene beads using FSC and SSC signals. Our platform shows promise for optical and fluidic miniaturization of flow cytometry systems.

  5. Laser Refractography

    CERN Document Server

    Rinkevichyus, B.S; Raskovskaya, I.L

    2010-01-01

    This book describes the basic principles of laser refractography, a flexible new diagnostic tool for measuring optically inhomogeneous media and flows. Laser refractography is based on digital imaging and computer processing of structured laser beam refraction (SLR) in inhomogeneous transparent media. Laser refractograms provide both qualitative and quantitative measurements and can be used for the study of fast and transient processes. In this book, the theoretical basis of refractography is explored in some detail, and experimental setups are described for measurement of transparent media using either 2D (passed radiation) or 3D (scattered radiation) refractograms. Specific examples and applications are discussed, including visualization of the boundary layer near a hot or cold metallic ball in water, and observation of edge effects and microlayers in liquids and gases. As the first book to describe this new and exciting technique, this monograph has broad cross-disciplinary appeal and will be of interest t...

  6. Forecasting method in multilateration accuracy based on laser tracker measurement

    International Nuclear Information System (INIS)

    Aguado, Sergio; Santolaria, Jorge; Samper, David; José Aguilar, Juan

    2017-01-01

    Multilateration based on a laser tracker (LT) requires the measurement of a set of points from three or more positions. Although the LTs’ angular information is not used, multilateration produces a volume of measurement uncertainty. This paper presents two new coefficients from which to determine whether the measurement of a set of points, before performing the necessary measurements, will improve or worsen the accuracy of the multilateration results, avoiding unnecessary measurement, and reducing the time and economic cost required. The first specific coefficient measurement coefficient (MC LT ) is unique for each laser tracker. It determines the relationship between the radial and angular laser tracker measurement noise. Similarly, the second coefficient is related with specific conditions of measurement β . It is related with the spatial angle between the laser tracker positions α and its effect on error reduction. Both parameters MC LT and β are linked in error reduction limits. Beside these, a new methodology to determine the multilateration reduction limit according to the multilateration technique of an ideal laser tracker distribution and a random one are presented. It provides general rules and advice from synthetic tests that are validated through a real test carried out in a coordinate measurement machine. (paper)

  7. Non-Topographic Space-Based Laser Remote Sensing

    Science.gov (United States)

    Yu, Anthony W.; Abshire, James B.; Riris, Haris; Purucker, Michael; Janches, Diego; Getty, Stephanie; Krainak, Michael A.; Stephen, Mark A.; Chen, Jeffrey R.; Li, Steve X.; hide

    2016-01-01

    In the past 20+ years, NASA Goddard Space Flight Center (GSFC) has successfully developed and flown lidars for mapping of Mars, the Earth, Mercury and the Moon. As laser and electro-optics technologies expand and mature, more sophisticated instruments that once were thought to be too complicated for space are being considered and developed. We will present progress on several new, space-based laser instruments that are being developed at GSFC. These include lidars for remote sensing of carbon dioxide and methane on Earth for carbon cycle and global climate change; sodium resonance fluorescence lidar to measure environmental parameters of the middle and upper atmosphere on Earth and Mars and a wind lidar for Mars orbit; in situ laser instruments include remote and in-situ measurements of the magnetic fields; and a time-of-flight mass spectrometer to study the diversity and structure of nonvolatile organics in solid samples on missions to outer planetary satellites and small bodies.

  8. High-average-power laser medium based on silica glass

    Science.gov (United States)

    Fujimoto, Yasushi; Nakatsuka, Masahiro

    2000-01-01

    Silica glass is one of the most attractive materials for a high-average-power laser. We have developed a new laser material base don silica glass with zeolite method which is effective for uniform dispersion of rare earth ions in silica glass. High quality medium, which is bubbleless and quite low refractive index distortion, must be required for realization of laser action. As the main reason of bubbling is due to hydroxy species remained in the gelation same, we carefully choose colloidal silica particles, pH value of hydrochloric acid for hydrolysis of tetraethylorthosilicate on sol-gel process, and temperature and atmosphere control during sintering process, and then we get a bubble less transparent rare earth doped silica glass. The refractive index distortion of the sample also discussed.

  9. Fundamentals of metasurface lasers based on resonant dark states

    International Nuclear Information System (INIS)

    Droulias, Sotiris; Technology - Hellas; Jain, Aditya; Koschny, Thomas; Soukoulis, Costas M.; Technology - Hellas; Ames Laboratory and Iowa State University, Ames, IA

    2017-01-01

    Recently, our group proposed a metamaterial laser design based on explicitly coupled dark resonant states in low-loss dielectrics, which conceptually separates the gain-coupled resonant photonic state responsible for macroscopic stimulated emission from the coupling to specific free-space propagating modes, allowing independent adjustment of the lasing state and its coherent radiation output. Due to this functionality, it is now possible to make lasers that can overcome the trade-off between system dimensions and Q factor, especially for surface emitting lasers with deeply subwavelength thickness. In this paper, we give a detailed discussion of the key functionality and benefits of this design, such as radiation damping tunability, directionality, subwavelength integration, and simple layer-by-layer fabrication. Finally, we examine in detail the fundamental design tradeoffs that establish the principle of operation and must be taken into account and give guidance for realistic implementations.

  10. Assessment of Laser Induced Ablation Spectroscopy (LIAS) as a method for quantitative in situ surface diagnostic in plasma environments

    International Nuclear Information System (INIS)

    Gierse, Niels Hannes Gustav

    2014-01-01

    In this work Laser Induced Ablation Spectroscopy (LIAS) is investigated as an in situ plasma surface interaction diagnostic for fusion reactors and fusion experiments. In LIAS an intensive laser pulse is used to ablate the material under investigation during plasma operation. Ablation products penetrate into the edge region of the plasma and are excited and ionized. In case of molecules and clusters additionally dissociation occurs. The emitted line radiation is observed by radiometric calibrated spectroscopy. Results from LIAS of W/C/Al/D-mixed layers and amorphous hydrocarbon layers are presented. Using a fast camera system time resolved measurements of the LIAS.process could be performed, allowing investigation of the temporal behavior of excitation, dissociation and ionization processes. For Tungsten, 90% of the LIAS light is observed within 10±3 μs after the laser pulse. In case of carbon within 20±3 μs. Additionally separation in time of LIAS emission and the LIBS emission caused by the laser pulse at the surface within single measurements was demonstrated. This allows the separate analysis of both processes in a coaxial setup which is foreseen for future experiments. The inverse photon efficiency of the Balmer D_α-emission from LIAS of a-C:D-layers was found to be [(D)/(XB)]"a"-"C":"D""L""I""A""S"_→"D_D__α=71±7. The plasma perturbation due to LIAS was investigated by laser energy density variation when ablating W/C/Al/D.mixed layers. Local plasma perturbation is found to increase with laser energy density. Balmer H_γ/H_δ - line intensity ratio measurements only show for ohmic discharges and the case of the lowest central density signs of local plasma perturbation in LIAS of graphite samples. A simple analytical model for local plasma perturbation during LIAS is introduced and evaluated. Qualitative agreement between the model and the above reported experimental observations is found; a stronger influence on local conditions is found by tungsten

  11. Improvement of malaria diagnostic system based on acridine orange staining.

    Science.gov (United States)

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  12. Precise Charge Measurement For Laser Plasma Accelerators

    International Nuclear Information System (INIS)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Sokollik, Thomas; Shiraishi, Satomi; van Tilborg, Jeroen; Osterhoff, Jens; Donahue, Rich; Rodgers, David; Smith, Alan; Byrne, Warren; Leemans, Wim

    2011-01-01

    Cross-calibrations of charge diagnostics are conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). Employed diagnostics are a scintillating screen, activation based measurement, and integrating current transformer. The diagnostics agreed within ±8 %, showing that they can provide accurate charge measurements for LPAs provided they are used properly.

  13. A WAO - ARIA - GA2LEN consensus document on molecular-based allergy diagnostics

    DEFF Research Database (Denmark)

    Canonica, Giorgio Walter; Ansotegui, Ignacio J; Pawankar, Ruby

    2013-01-01

    Molecular-based allergy (MA) diagnostics is an approach used to map the allergen sensitization of a patient at a molecular level, using purified natural or recombinant allergenic molecules (allergen components) instead of allergen extracts. Since its introduction, MA diagnostics has increasingly ...

  14. Fetal Implications of Diagnostic Radiation Exposure During Pregnancy: Evidence-based Recommendations.

    Science.gov (United States)

    Rimawi, Bassam H; Green, Victoria; Lindsay, Michael

    2016-06-01

    The purpose of this article is to review the fetal and long-term implications of diagnostic radiation exposure during pregnancy. Evidence-based recommendations for radiologic imaging modalities utilizing exposure of diagnostic radiation during pregnancy, including conventional screen-film mammography, digital mammography, tomosynthesis, and contrast-enhanced mammography are described.

  15. Nanographene-Based Saturable Absorbers for Ultrafast Fiber Lasers

    Directory of Open Access Journals (Sweden)

    Hsin-Hui Kuo

    2014-01-01

    Full Text Available The generation of femtosecond pulse laser in the erbium-doped fiber laser system is presented by integrating of the nanographene-based saturable absorbers (SAs. A simplified method of dispersed nanographene-based SAs side-polished fiber device with controllable polished length and depth was also developed. The dependence of geometry of a graphene-deposited side-polished fiber device on optical nonlinear characteristics and on the performance of the MLFL was screened. We found that the 10 mm polished length with 1.68 dB insertion loss had the highest modulation depth (MD of 1.2%. A stable MLFL with graphene-based SAs employing the optimized side-polished fiber device showed a pulse width, a 3 dB bandwidth, a time-bandwidth product (TBP, a repetition rate, and pulse energy of 523 fs, 5.4 nm, 0.347, 16.7 MHz, and 0.18 nJ, respectively, at fundamental soliton-like operation. The femtosecond pulse laser is achieved by evanescent field coupling through graphene-deposited side-polished fiber devices in the laser cavity. This study demonstrates that the polished depth is the key fabrication geometric parameter affecting the overall optical performance and better results exist within the certain polished range.

  16. Fiber-based laser MOPA transmitter packaging for space environment

    Science.gov (United States)

    Stephen, Mark; Yu, Anthony; Chen, Jeffrey; Numata, Kenji; Wu, Stewart; Gonzales, Brayler; Han, Lawrence; Fahey, Molly; Plants, Michael; Rodriguez, Michael; Allan, Graham; Abshire, James; Nicholson, Jeffrey; Hariharan, Anand; Mamakos, William; Bean, Brian

    2018-02-01

    NASA's Goddard Space Flight Center has been developing lidar to remotely measure CO2 and CH4 in the Earth's atmosphere. The ultimate goal is to make space-based satellite measurements with global coverage. We are working on maturing the technology readiness of a fiber-based, 1.57-micron wavelength laser transmitter designed for use in atmospheric CO2 remote-sensing. To this end, we are building a ruggedized prototype to demonstrate the required power and performance and survive the required environment. We are building a fiber-based master oscillator power amplifier (MOPA) laser transmitter architecture. The laser is a wavelength-locked, single frequency, externally modulated DBR operating at 1.57-micron followed by erbium-doped fiber amplifiers. The last amplifier stage is a polarization-maintaining, very-large-mode-area fiber with 1000 μm2 effective area pumped by a Raman fiber laser. The optical output is single-frequency, one microsecond pulses with >450 μJ pulse energy, 7.5 KHz repetition rate, single spatial mode, and < 20 dB polarization extinction.

  17. Beam manipulation for compact laser wakefield accelerator based free-electron lasers

    International Nuclear Information System (INIS)

    Loulergue, A; Labat, M; Benabderrahmane, C; Couprie, M E; Evain, C; Malka, V

    2015-01-01

    Free-electron lasers (FELs) are a unique source of light, particularly in the x-ray domain. After the success of FELs based on conventional acceleration using radio-frequency cavities, an important challenge is the development of FELs based on electron bunching accelerated by a laser wakefield accelerator (LWFA). However, the present LWFA electron bunch properties do not permit use directly for a significant FEL amplification. It is known that longitudinal decompression of electron beams delivered by state-of-the-art LWFA eases the FEL process. We propose here a second order transverse beam manipulation turning the large inherent transverse chromatic emittances of LWFA beams into direct FEL gain advantage. Numerical simulations are presented showing that this beam manipulation can further enhance by orders of magnitude the peak power of the radiation. (paper)

  18. Coherent transition radiation from a laser wakefield accelerator as an electron bunch diagnostic

    International Nuclear Information System (INIS)

    Tilborg, J. van; Geddes, C.G.R.; Toth, C.; Esarey, E.; Schroeder, C.B.; Martin, M.C.; Hao, Z.; Leemans, W.P.

    2004-01-01

    The observation and modeling of coherent transition radiation from femtosecond laser accelerated electron bunches is discussed. The coherent transition radiation, scaling quadratically with bunch charge, is generated as the electrons transit the plasma-vacuum boundary. Due to the limited transverse radius of the plasma boundary, diffraction effects will strongly modify the angular distribution and the total energy radiated is reduced compared to an infinite transverse boundary. The multi-nC electron bunches, concentrated in a length of a few plasma periods (several tens of microns), experience partial charge neutralization while propagating inside the plasma towards the boundary. This reduces the space-charge blowout of the beam, allowing for coherent radiation at relatively high frequencies (several THz). The charge distribution of the electron bunch at the plasma-vacuum boundary can be derived from Fourier analysis of the coherent part of the transition radiation spectrum. A Michelson interferometer was used to measure the coherent spectrum, and electron bunches with duration on the order of 50 fs (rms) were observed

  19. Quantitative laser diagnostic and modeling study of C2 and CH chemistry in combustion.

    Science.gov (United States)

    Köhler, Markus; Brockhinke, Andreas; Braun-Unkhoff, Marina; Kohse-Höinghaus, Katharina

    2010-04-15

    Quantitative concentration measurements of CH and C(2) have been performed in laminar, premixed, flat flames of propene and cyclopentene with varying stoichiometry. A combination of cavity ring-down (CRD) spectroscopy and laser-induced fluorescence (LIF) was used to enable sensitive detection of these species with high spatial resolution. Previously, CH and C(2) chemistry had been studied, predominantly in methane flames, to understand potential correlations of their formation and consumption. For flames of larger hydrocarbon fuels, however, quantitative information on these small intermediates is scarce, especially under fuel-rich conditions. Also, the combustion chemistry of C(2) in particular has not been studied in detail, and although it has often been observed, its role in potential build-up reactions of higher hydrocarbon species is not well understood. The quantitative measurements performed here are the first to detect both species with good spatial resolution and high sensitivity in the same experiment in flames of C(3) and C(5) fuels. The experimental profiles were compared with results of combustion modeling to reveal details of the formation and consumption of these important combustion molecules, and the investigation was devoted to assist the further understanding of the role of C(2) and of its potential chemical interdependences with CH and other small radicals.

  20. Velocimetry using scintillation of a laser beam for a laser-based gas-flux monitor

    Science.gov (United States)

    Kagawa, Naoki; Wada, Osami; Koga, Ryuji

    1999-05-01

    This paper describes a velocimetry system using scintillation of a laser-beam with spatial filters based on sensor arrays for a laser- based gas flux monitor. In the eddy correlation method, gas flux is obtained by mutual relation between the gas density and the flow velocity. The velocimetry system is developed to support the flow velocity monitor portion of the laser-based gas flux monitor with a long span for measurement. In order to sense not only the flow velocity but also the flow direction, two photo diode arrays are arranged with difference of a quarter period of the weighting function between them; the two output signals from the sensor arrays have phase difference of either (pi) /2 or -(pi) /2 depending on the sense of flow direction. In order to obtain the flow velocity and the flow direction instantly, an electronic apparatus built by the authors extracts frequency and phase from crude outputs of the pair of sensors. A feasibility of the velocimetry was confirmed indoors by measurement of the flow- velocity vector of the convection. Measured flow-velocity vector of the upward flow agreed comparatively with results of an ultrasonic anemometer.