WorldWideScience

Sample records for lars artificial ligament

  1. Thermographic and microscopic evaluation of LARS knee ligament tearing.

    Science.gov (United States)

    Pătraşcu, Jenel Marian; Amarandei, Mihaela; Kun, Karla Noemy; Borugă, Ovidiu; Totorean, Alina; Andor, Bogdan; Florescu, Sorin

    2014-01-01

    Damage to knee articular ligaments causes important functional problems and adversely affects particularly the stability of the knee joint. Several methods were developed in order to repair damage to the anterior cruciate ligament (ACL), which employ autografts, allografts, as well as synthetic ligaments. One such synthetic scaffold, the ligament advanced reinforcement system (LARS) synthetic ligament is made of non-absorbing polyethylene terephthalate fibers whose structure allow tissue ingrowths in the intra-articular part, improving the stability of the joint. The LARS ligament is nowadays widely used in modern knee surgery in the Europe, Canada, China or Japan. This paper evaluates LARS ligament from two perspectives. The first regards a study done by the Orthopedics Clinic II, Timisoara, Romania, which compared results obtained by employing two techniques of ACL repair - the Bone-Tendon-Bone (BTB) or LARS arthroscopic, intra-articular techniques. This study found that patients treated with the BTB technique presented with an IKDC score of 45.82±1.14 units preoperative, with increasing values in the first nine months after each implant post-surgical ligament restoration, reaching an average value of 75.92 ± 2.88 units postoperative. Patients treated with the LARS technique presented with an IKDC score of 43.64 ± 1.11 units preoperative, and a score of 77.32 ± 2.71 units postoperative. The second perspective describes the thermographic and microscopic analysis of an artificial knee ligament tearing or loosening. The objective of the study was to obtain information regarding the design of artificial ligaments in order to expand their lifespan and avoid complications such as recurring synovitis, osteoarthritis and trauma of the knee joint. Thermographic data has shown that tearing begins from the inside out, thus improving the inner design of the ligament would probably enhance its durability. An optical microscope was employed to obtain images of structural

  2. The treatment of the acute acromioclavicular joint dislocation with LARS artificial ligament:a preliminary report%应用LARS人工韧带治疗急性肩锁关节脱位的初步报告

    Institute of Scientific and Technical Information of China (English)

    陈爱民; 鹿楠; 叶添文; 杨鹏; 朱磊; 李菁

    2014-01-01

    Background Currently,the clinical perspectives of surgical treatment for Tossy Ⅲacromioclavicular(AC)joint dislocations are relatively identical.Due to the post-traumatic ruptures of the acromioclavicular ligament and coracoclavicular(CC)ligament which are used to maintain stability of the joint,the clavicle moves backward and upward,and the upper arm and the scapula drops downward for the gravity of the upper arm and the influence of the sternocleidomastoid muscle.Since such complications as reduction difficulties,redislocation after external fixation,pressure ulcers of the skin,and so forth are particularly prone to occur in the conservative therapy,the operative treatment is more inclined to be adopted for the Tossy Ⅲ dislocation of the AC joint.With the single repair and fixation of the CC ligament,redislocation is likely to happen after implant removal because the ruptured ligaments healed as scar tissue.Therefore,this study uses an operative method of reconstructing and augmenting the CC ligament with LARS artificial ligament for the treatment of Tossy Ⅲ AC joint dislocation,and evaluates its clinical effect.Methods From November 2006 to July 2009,8 patients with acute AC joint dislocation of Tossy Ⅲ were admitted into our hospital.Five patients were male and 3 were female,and their ages ranged from 21 to 45.Sides:3 injuries were on the left and 5 were on the right.Seven patients suffered from falling on the ground,and 1 patient was inj ured in a traffic accident.All the patients were treated with LARS artificial ligaments to reconstruct the CC ligament.Constant score and VAS score were adopted in clinical evaluation.Zanca view of the bilateral AC joint and the axillary radiograph of the affected shoulder joint were employed for imaging evaluation.All the patients were simple Tossy Ⅲ dislocation of AC joint with no trauma of other parts and skin breakdown.Regular pre-operative examinations and evaluations were carried out after admission,and LARS

  3. Status and headway of the clinical application of artificial ligaments

    Directory of Open Access Journals (Sweden)

    Tianwu Chen

    2015-01-01

    Full Text Available The authors first reviewed the history of clinical application of artificial ligaments. Then, the status of clinical application of artificial ligaments was detailed. Some artificial ligaments possessed comparable efficacy to, and fewer postoperative complications than, allografts and autografts in ligament reconstruction, especially for the anterior cruciate ligament. At the end, the authors focused on the development of two types of artificial ligaments: polyethylene glycol terephthalate artificial ligaments and tissue-engineered ligaments. In conclusion, owing to the advancements in surgical techniques, materials processing, and weaving methods, clinical application of some artificial ligaments so far has demonstrated good outcomes and will become a trend in the future.

  4. Artificial phrenoesophageal ligament. An experimental study in dogs.

    Science.gov (United States)

    Sader, A A; Dantas, R O; Campos, A D; Evora, P R B

    2016-01-01

    This report deals with the preparation of a 'true' artificial phrenoesophageal ligament aimed at restoring effective anchoring of the esophagus to the diaphragm, keeping the esophagogastric sphincter in the abdomen. A total of 24 mongrel dogs were assigned to four groups: (i) Group I (n = 4): the esophageal diaphragm hiatus left wide open; (ii) Group II (n = 8): the anterolateral esophagus walls were attached to the diaphragm by the artificial ligament and the esophageal hiatus was left wide opened; (iii) Group III (n = 5): in addition to the use of the artificial ligament, the esophageal hiatus was narrowed with two retroesophageal stitches; (iv) Group IV (n = 7): the only procedure was the esophageal hiatus narrowing with two retroesophageal stitches. The phrenoesophagogastric connections were released, sparing the vagus nerves. Five animals of groups III and IV, which did not develop hiatal hernia, were submitted to esophageal manometry immediately before and 15 days after surgery. In group I, all animals developed huge sliding hiatal hernias. In group II, two dogs (25%) had a paraesophageal hernia between the two parts of the artificial ligament. In group III, neither sliding hiatal hernia nor paraesophageal hernia occurred. In group IV, two animals (28.6%) developed sliding esophageal hiatus hernia. Regarding esophageal manometry, postoperative significant difference between groups III and IV (P = 0.008) was observed. Thus, the artificial phrenoesophageal ligament maintained the esophagus firmly attached to the diaphragm in all animals and the esophagogastric sphincter pressure was significantly higher in this group. © 2015 International Society for Diseases of the Esophagus.

  5. An osteogenesis/angiogenesis-stimulation artificial ligament for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Li, Hong; Li, Jinyan; Jiang, Jia; Lv, Fang; Chang, Jiang; Chen, Shiyi; Wu, Chengtie

    2017-05-01

    To solve the poor healing of polyethylene terephthalate (PET) artificial ligament in bone tunnel, copper-containing bioactive glass (Cu-BG) nanocoatings on PET artificial ligaments were successfully prepared by pulsed laser deposition (PLD). It was hypothesized that Cu-BG coated PET (Cu-BG/PET) grafts could enhance the in vitro osteogenic and angiogenic differentiation of rat bone marrow mesenchymal stem cells (rBMSCs) and in vivo graft-bone healing after anterior cruciate ligament (ACL) reconstruction in a goat model. Scanning electron microscope and EDS mapping analysis revealed that the prepared nanocoatings had uniform element distribution (Cu, Ca, Si and P) and nanostructure. The surface hydrophilicity of PET grafts was significantly improved after depositing Cu-BG nanocoatings. The in vitro study displayed that the Cu-BG/PET grafts supported the attachment and proliferation of rBMSCs, and significantly promoted the expression of HIF-1α gene, which up-regulated the osteogenesis-related genes (S100A10, BMP2, OCN) and angiogenesis-related genes (VEGF) in comparison with PET or BG coated PET (BG/PET) grafts which do not contain Cu element. Meanwhile, Cu-BG/PET grafts promoted the bone regeneration at the graft-host bone interface and decreased graft-bone interface width, thus enhancing the bonding strength as well as angiogenesis (as indicated by CD31 expression) in the goat model as compared with BG/PET and pure PET grafts. The study demonstrates that the Cu-containing biomaterials significantly promote osteogenesis and angiogenesis in the repair of bone defects of large animals and thus offering a promising method for ACL reconstruction by using Cu-containing nanobioglass modified PET grafts. It remains a significant challenge to develop an artificial graft with distinct osteogenetic/angiogenetic activity to enhance graft-bone healing for ligament reconstruction. To solve these problems, copper-containing bioactive glass (Cu-BG) nanocoatings on PET artificial

  6. Development of a Tissue-Engineered Artificial Ligament: Reconstruction of Injured Rabbit Medial Collateral Ligament With Elastin-Collagen and Ligament Cell Composite Artificial Ligament.

    Science.gov (United States)

    Hirukawa, Masaki; Katayama, Shingo; Sato, Tatsuya; Inoue, Kota; Niwa, Kosuke; Ito, Naoya; Hattori, Tetsuya; Hosoi, Takashi; Unno, Hironori; Suzuki, Yoshiaki; Hasegawa, Masahiro; Miyamoto, Keiichi; Horiuchi, Takashi

    2018-04-16

    Ligament reconstruction using a tissue-engineered artificial ligament (TEAL) requires regeneration of the ligament-bone junction such that fixation devices such as screws and end buttons do not have to be used. The objective of this study was to develop a TEAL consisting of elastin-coated polydioxanone (PDS) sutures covered with elastin and collagen fibers preseeded with ligament cells. In a pilot study, a ring-type PDS suture with a 2.5 mm (width) bone insertion was constructed with/without elastin coating (Ela-coat and Non-coat) and implanted into two bone tunnels, diameter 2.4 mm, in the rabbit tibia (6 cases each) to access the effect of elastin on the bond strength. PDS specimens taken together with the tibia at 6 weeks after implantation indicated growth of bone-like hard tissues around bone tunnels accompanied with narrowing of the tunnels in the Ela-coat group and not in the Non-coat group. The drawout load of the Ela-coat group was significantly higher (28.0 ± 15.1 N, n = 4) than that of the Non-coat group (7.6 ± 4.6 N, n = 5). These data can improve the mechanical bulk property of TEAL through extracellular matrix formation. To achieve this TEAL model, 4.5 × 10 6 ligament cells were seeded on elastin and collagen fibers (2.5 cm × 2.5 cm × 80 µm) prior to coil formation around the elastin-coated PDS core sutures having ball-shape ends with a diameter of 2.5 mm. Cell-seeded and cell-free TEALs were implanted across the femur and the tibia through bone tunnels with a diameter of 2.4 mm (6 cases each). There was no incidence of TEAL being pulled in 6 weeks. Regardless of the remarkable degradation of PDS observed in the cell-seeded group, both the elastic modulus and breaking load of the cell-seeded group (n = 3) were comparable to those of the sham-operation group (n = 8) (elastic modulus: 15.4 ± 1.3 MPa and 18.5 ± 5.7 MPa; breaking load: 73.0 ± 23.4 N and 104.8 ± 21.8 N, respectively) and higher than those

  7. Effects of Artificial Ligaments with Different Porous Structures on the Migration of BMSCs

    Directory of Open Access Journals (Sweden)

    Chun-Hui Wang

    2015-01-01

    Full Text Available Polyethylene terephthalate- (PET- based artificial ligaments (PET-ALs are commonly used in anterior cruciate ligament (ACL reconstruction surgery. The effects of different porous structures on the migration of bone marrow mesenchymal stem cells (BMSCs on artificial ligaments and the underlying mechanisms are unclear. In this study, a cell migration model was utilized to observe the migration of BMSCs on PET-ALs with different porous structures. A rabbit extra-articular graft-to-bone healing model was applied to investigate the in vivo effects of four types of PET-ALs, and a mechanical test and histological observation were performed at 4 weeks and 12 weeks. The BMSC migration area of the 5A group was significantly larger than that of the other three groups. The migration of BMSCs in the 5A group was abolished by blocking the RhoA/ROCK signaling pathway with Y27632. The in vivo study demonstrated that implantation of 5A significantly improved osseointegration. Our study explicitly demonstrates that the migration ability of BMSCs can be regulated by varying the porous structures of the artificial ligaments and suggests that this regulation is related to the RhoA/ROCK signaling pathway. Artificial ligaments prepared using a proper knitting method and line density may exhibit improved biocompatibility and clinical performance.

  8. Reconstruction of chronic acromioclavicular joint disruption with artificial ligament prosthesis

    Directory of Open Access Journals (Sweden)

    Chouhan Devendra Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: Management of Rockwood type 3 acromioclavicular disruptions is a matter of debate. Should we adopt conservative or operative measures at first presentation? It is not clear but most of the evidences are in favour of conservative management. We present our expe-rience in managing these patients surgically. Methods: We present a prospective series of eight cases of chronic Rockwood type 3 acromioclavicular joint disruptions treated surgically. Anatomical reconstruction of the coracoclavicular ligament was done by artificial braided polyester ligament prosthesis. Results: All the patients were able to perform daily activities from an average of the 14th postoperative day. All patients felt an improvement in pain, with decrease in ave-rage visual analogue scale from preoperative 6.5 points (range 3-9 points to 2.0 points (range 0-5 points, Constant score from 59% to 91% and American Shoulder and Elbow Surgeons shoulder score from 65 to 93 points postoperatively. These results improved or at least remained stationary on midterm follow-up, and no deterioration was recorded at an average follow-up of 46 months. Conclusion: This midterm outcome analysis of the artificial ligament prosthesis is the first such follow-up study with prosthesis. Our results are encouraging and justify the further use and evaluation of this relatively new and easily reproducible technique. Key words: Acromioclavicular joint; Prostheses and implants; Reconstructive surgical procedures; Ligaments

  9. Formation of Apatite Coatings on an Artificial Ligament Using a Plasma- and Precursor-Assisted Biomimetic Process

    Directory of Open Access Journals (Sweden)

    Ayako Oyane

    2013-09-01

    Full Text Available A plasma- and precursor-assisted biomimetic process utilizing plasma and alternate dipping treatments was applied to a Leed-Keio artificial ligament to produce a thin coating of apatite in a supersaturated calcium phosphate solution. Following plasma surface modification, the specimen was alternately dipped in calcium and phosphate ion solutions three times (alternate dipping treatment to create a precoating containing amorphous calcium phosphate (ACP which is an apatite precursor. To grow an apatite layer on the ACP precoating, the ACP-precoated specimen was immersed for 24 h in a simulated body fluid with ion concentrations approximately equal to those in human blood plasma. The plasma surface modification was necessary to create an adequate apatite coating and to improve the coating adhesion depending on the plasma power density. The apatite coating prepared using the optimized conditions formed a thin-film that covered the entire surface of the artificial ligament. The resulting apatite-coated artificial ligament should exhibit improved osseointegration within the bone tunnel and possesses great potential for use in ligament reconstructions.

  10. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  11. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  12. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  13. Development of Tissue-Engineered Ligaments: Elastin Promotes Regeneration of the Rabbit Medial Collateral Ligament.

    Science.gov (United States)

    Hirukawa, Masaki; Katayama, Shingo; Sato, Tatsuya; Yamada, Masayoshi; Kageyama, Satoshi; Unno, Hironori; Suzuki, Yoshiaki; Miura, Yoshihiro; Shiratsuchi, Eri; Hasegawa, Masahiro; Miyamoto, Keiichi; Horiuchi, Takashi

    2017-12-21

    When ligaments are injured, reconstructive surgery is sometimes required to restore function. Methods of reconstructive surgery include transplantation of an artificial ligament and autotransplantation of a tendon. However, these methods have limitations related to the strength of the bone-ligament insertion and biocompatibility of the transplanted tissue after surgery. Therefore, it is necessary to develop new reconstruction methods and pursue the development of artificial ligaments. Elastin is a major component of elastic fibers and ligaments. However, the role of elastin in ligament regeneration has not been described. Here, we developed a rabbit model of a medial collateral ligament (MCL) rupture and treated animal knees with exogenous elastin [100 µg/(0.5 mL·week)] for 6 or 12 weeks. Elastin treatment increased gene expression and protein content of collagen and elastin (gene expression, 6-fold and 42-fold, respectively; protein content, 1.6-fold and 1.9-fold, respectively), and also increased the elastic modulus of MCL increased with elastin treatment (2-fold) compared with the controls. Our data suggest that elastin is involved in the regeneration of damaged ligaments. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai [Department of Sports Medicine, Huashan Hospital, Shanghai (China); Zhang Pengyun; Wu Lingxiang [Shanghai Research Center of Biomedical Engineering, Shanghai (China); Chen Shiyi, E-mail: cshiyi@163.com [Department of Sports Medicine, Huashan Hospital, Shanghai (China)

    2011-09-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  15. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    International Nuclear Information System (INIS)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai; Zhang Pengyun; Wu Lingxiang; Chen Shiyi

    2011-01-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  16. The effect of polystyrene sodium sulfonate grafting on polyethylene terephthalate artificial ligaments on in vitro mineralisation and in vivo bone tissue integration

    Science.gov (United States)

    Vaquette, Cédryck; Viateau, Véronique; Guérard, Sandra; Anagnostou, Fani; Manassero, Mathieu; Castner, David G.; Migonney, Véronique

    2013-01-01

    This study investigates the impact of polystyrene sodium sulfonate (PolyNaSS) grafting onto the osseointegration of a polyethylene terephthalate artificial ligament (Ligament Advanced Reinforcement System, LARS™) used for Anterior Cruciate Ligament (ACL). The performance of grafted and non-grafted ligaments was assessed in vitro by culturing human osteoblasts under osteogenic induction and this demonstrated that the surface modification was capable of up-regulating the secretion of ALP and induced higher level of mineralisation as measured 6 weeks post-seeding by Micro-Computed Tomography. Grafted and non-grafted LARS™ were subsequently implanted in an ovine model for ACL reconstruction and the ligament-to-bone interface was evaluated by histology and biomechanical testing 3 and 12 months post-implantation. The grafted ligaments exhibited more frequent direct ligament-to-bone contact and bone formation in the core of the ligament at the later time point than the nongrafted specimens, the grafting also significantly reduced the fibrous encapsulation of the ligament 12 months post-implantation. However, this improved osseo-integration was not translated into a significant increase in the biomechanical pull-out loads. These results provide evidences that PolyNaSS grafting improved the osseo-integration of the artificial ligament within the bone tunnels. This might positively influence the outcome of the surgical reconstructions, as higher ligament stability is believed to limit micro-movement and therefore permits earlier and enhanced healing. PMID:23790438

  17. Surface modification of nano-silica on the ligament advanced reinforcement system for accelerated bone formation: primary human osteoblasts testing in vitro and animal testing in vivo.

    Science.gov (United States)

    Li, Mengmeng; Wang, Shiwen; Jiang, Jia; Sun, Jiashu; Li, Yuzhuo; Huang, Deyong; Long, Yun-Ze; Zheng, Wenfu; Chen, Shiyi; Jiang, Xingyu

    2015-05-07

    The Ligament Advanced Reinforcement System (LARS) has been considered as a promising graft for ligament reconstruction. To improve its biocompatibility and effectiveness on new bone formation, we modified the surface of a polyethylene terephthalate (PET) ligament with nanoscale silica using atom transfer radical polymerization (ATRP) and silica polymerization. The modified ligament is tested by both in vitro and in vivo experiments. Human osteoblast testing in vitro exhibits an ∼21% higher value in cell viability for silica-modified grafts compared with original grafts. Animal testing in vivo shows that there is new formed bone in the case of a nanoscale silica-coated ligament. These results demonstrate that our approach for nanoscale silica surface modification on LARS could be potentially applied for ligament reconstruction.

  18. The effect of layer-by-layer chitosan-hyaluronic acid coating on graft-to-bone healing of a poly(ethylene terephthalate) artificial ligament.

    Science.gov (United States)

    Li, Hong; Ge, Yunsheng; Zhang, Pengyun; Wu, Lingxiang; Chen, Shiyi

    2012-01-01

    Surface coating with an organic layer-by-layer self-assembled template of chitosan and hyaluronic acid on a poly(ethylene terephthalate) (PET) artificial ligament was designed for the promotion and enhancement of graft-to-bone healing after artificial ligament implantation in a bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells supported the hypothesis that the layer-by-layer coating of chitosan and hyaluronic acid could promote the cell compatibility of grafts and could promote osteoblast proliferation. A rabbit extra-articular tendon-to-bone healing model was used to evaluate the effect of this kind of surface-modified stainless artificial ligament in vivo. The final results proved that this organic compound coating could significantly promote and enhance new bone formation at the graft-bone interface histologically and, correspondingly, the experimental group with coating had significantly higher biomechanical properties compared with controls at 8 weeks (P < 0.05).

  19. Local delivery of controlled-release simvastatin to improve the biocompatibility of polyethylene terephthalate artificial ligaments for reconstruction of the anterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Zhang P

    2016-01-01

    Full Text Available Peng Zhang,1,* Fei Han,2,* Yunxia Li,1 Jiwu Chen,1 Tianwu Chen,1 Yunlong Zhi,1 Jia Jiang,1 Chao Lin,2 Shiyi Chen,1 Peng Zhao2 1Department of Sports Medicine, Huashan Hospital, Fudan University, 2Shanghai East Hospital, The Institute for Biomedical Engineering and Nanoscience, School of Medicine, Tongji University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: The Ligament Advanced Reinforcement System has recently been widely used as the primary graft of choice in anterior cruciate ligament (ACL reconstruction. But the biological graft–bone healing still remains a problem. Previous studies have shown that simvastatin (SIM stimulates bone formation. The objective of this study was to investigate whether surface coating with collagen containing low-dose SIM microsphere could enhance the surface biocompatibility of polyethylene terephthalate (PET artificial ligaments to accelerate graft-to-bone healing. The in vitro studies demonstrated that bone marrow stromal cells on the collagen-coated PET scaffolds (COL/PET and simvastatin/collagen-coated PET scaffolds (SIM/COL/PET proliferated vigorously. Compared with the PET group and the COL/PET group, SIM could induce bone marrow stromal cells’ osteoblastic differentiation, high alkaline phosphatase activity, more mineralization deposition, and more expression of osteoblast-related genes, such as osteocalcin, runt-related transcription factor 2, bone morphogenetic protein-2, and vascular endothelial growth factor, in the SIM/COL/PET group. In vivo, rabbits received ACL reconstruction with different scaffolds. Histological analysis demonstrated that graft–bone healing was significantly greater with angiogenesis and osteogenesis in the SIM/COL/PET group than the other groups. In addition, biomechanical testing at the eighth week demonstrated a significant increase in the ultimate failure load and stiffness in the SIM/COL/PET group. The low dose of SIM

  20. Anterior Cruciate Ligament Reconstruction in Ehlers-Danlos Syndrome

    Directory of Open Access Journals (Sweden)

    John Williams

    2015-01-01

    Full Text Available This report details the reconstruction of the anterior cruciate ligament in an 18-year-old man with Ehlers-Danlos syndrome (EDS. The reduced mechanical properties of the tissue in EDS can pose a challenge to the orthopaedic surgeon. In this case, we describe the use of a hamstring autograft combined with a Ligament Advanced Reinforcement System (LARS. There was a good radiographical, clinical, and functional outcome after two years. This technique gave a successful outcome in the reconstruction of the ACL in a patient with EDS and therefore may help surgeons faced with the same clinical scenario.

  1. Artificial ligamentous joints:Methods, materials and characteristics

    OpenAIRE

    Hockings, Nick; Iravani, Pejman; Bowen, Chris

    2014-01-01

    This paper presents a novel method for making ligamentous articulations for robots. Ligamentous joints are widely found in animals, but they have been of limited appli- cation in robotics due to lack of analogous synthetic materials. The method presented combines 3D printing, tow laying and thermoplastic welding which enables manufacturing of this type of structure.

  2. Ligament Augmentation and Reconstruction System Failures in Repair of Grade V Acromioclavicular Joint Dislocation

    Directory of Open Access Journals (Sweden)

    Martin K.-H. Li

    2017-01-01

    Full Text Available The Ligament Augmentation and Reconstruction System® (LARS® represents a popular synthetic anatomical reduction method for acromioclavicular joint dislocation by means of coracoclavicular ligament reconstruction. To our knowledge, no early failure has been documented in the literature. We present two unusual cases of LARS failure, one at four months after implant and the other at three weeks, without obvious causes, requiring re-do reconstruction, and discuss potential contributory factors.

  3. Enhancement of osseointegration of polyethylene terephthalate artificial ligament by coating of silk fibroin and depositing of hydroxyapatite

    Science.gov (United States)

    Jiang, Jia; Wan, Fang; Yang, Jianjun; Hao, Wei; Wang, Yaxian; Yao, Jinrong; Shao, Zhengzhong; Zhang, Peng; Chen, Jun; Zhou, Liang; Chen, Shiyi

    2014-01-01

    Background Application of artificial ligament in anterior cruciate ligament reconstruction is one of the research focuses of sports medicine but the biological tendon–bone healing still remains a problem. The preliminary study of hydroxyapatite (HAP) coating on the polyethylene terephthalate (PET) surface could effectively induce the osteoblast differentiation, but the tendon–bone healing was still not stable. As a green synthesis process, the biomimetic mineralization can simulate the natural bone growth in vitro and in vivo. Methods HAP crystals were grown under the guide of silk fibroin (SF) PET surface by biomimetic route. Several techniques including scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy were utilized for proving the introduction of both SF and HAP. The viability and osseointegration of bone marrow stromal cells on the surface of three kinds of ligament, including PET group (non-coating group), PET+SF group (SF-coating group), and PET+SF+HAP group (combined HAP- and SF-coating group), were analyzed by CCK-8 assays and alkaline phosphatase (ALP) detection. Seventy-two mature male New Zealand rabbits were randomly divided into three groups. Among them, 36 rabbits were sacrificed for mechanical testing, and histological examination for the others. Results The SF and SF+HAP were successfully coated on the surface of PET fiber. The CCK-8 assay showed that the cell proliferation on PET+SF+HAP group was better than the other two groups from 24 to 120 hours. After 14 days of culture, the cells in the PET+SF+HAP group delivered higher levels of ALP than the other two groups. After 3 days of culture, the expression level of integrin β1 in the PET+SF+HAP group and PET+SF group were higher than in the PET group. The mean load to failure and the stiffness value of the PET+SF+HAP group were both higher than the other two groups. Hematoxylin and

  4. Enhancement of osseointegration of polyethylene terephthalate artificial ligament by coating of silk fibroin and depositing of hydroxyapatite.

    Science.gov (United States)

    Jiang, Jia; Wan, Fang; Yang, Jianjun; Hao, Wei; Wang, Yaxian; Yao, Jinrong; Shao, Zhengzhong; Zhang, Peng; Chen, Jun; Zhou, Liang; Chen, Shiyi

    2014-01-01

    Application of artificial ligament in anterior cruciate ligament reconstruction is one of the research focuses of sports medicine but the biological tendon-bone healing still remains a problem. The preliminary study of hydroxyapatite (HAP) coating on the polyethylene terephthalate (PET) surface could effectively induce the osteoblast differentiation, but the tendon-bone healing was still not stable. As a green synthesis process, the biomimetic mineralization can simulate the natural bone growth in vitro and in vivo. HAP crystals were grown under the guide of silk fibroin (SF) PET surface by biomimetic route. Several techniques including scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy were utilized for proving the introduction of both SF and HAP. The viability and osseointegration of bone marrow stromal cells on the surface of three kinds of ligament, including PET group (non-coating group), PET+SF group (SF-coating group), and PET+SF+HAP group (combined HAP- and SF-coating group), were analyzed by CCK-8 assays and alkaline phosphatase (ALP) detection. Seventy-two mature male New Zealand rabbits were randomly divided into three groups. Among them, 36 rabbits were sacrificed for mechanical testing, and histological examination for the others. The SF and SF+HAP were successfully coated on the surface of PET fiber. The CCK-8 assay showed that the cell proliferation on PET+SF+HAP group was better than the other two groups from 24 to 120 hours. After 14 days of culture, the cells in the PET+SF+HAP group delivered higher levels of ALP than the other two groups. After 3 days of culture, the expression level of integrin β1 in the PET+SF+HAP group and PET+SF group were higher than in the PET group. The mean load to failure and the stiffness value of the PET+SF+HAP group were both higher than the other two groups. Hematoxylin and eosin staining showed that new bone

  5. The LArIAT Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Nutini, Irene

    2017-09-20

    A short overview of the Liquid Argon In A Testbeam (LArIAT) experiment hosted at Fermilab is reported. This program supports the Liquid Argon Time Projection Chamber (LArTPC) Neutrino Experiments at Fermilab. The LArIAT program consists of a calibration of a LArTPC in a dedicated charged particle beamline. The first total pion interaction cross section measurement ever made on argon is presented here (preliminary result).

  6. Siber Saldırılar Siber Savaşlar ve Etkileri

    OpenAIRE

    Kara, Mahruze

    2013-01-01

    74 pages. İnternetin ortaya çıkması ile yararlarından faydalanılmaktadır. Ancak internetin zararları da mevcuttur. İnternet, dünya dengelerini değiştirmektedir. İnternet, siber saldırılara ve siber savaşlara aracılık eden bir alan olmuştur. Siber saldırılar, ülkelerin ulusal ve ekonomik güvenliğini sarsmaktadır. Siber savaşlar 5. boyutta yapılmaktadır. Bu çalışmada siber silahlar ile siber saldırılar ve siber savaşların etkileri işlenmiştir. Siber güvenlik önlemleri için çöz...

  7. Enhancement of osseointegration of polyethylene terephthalate artificial ligament by coating of silk fibroin and depositing of hydroxyapatite

    Directory of Open Access Journals (Sweden)

    Jiang J

    2014-09-01

    Full Text Available Jia Jiang,1,2 Fang Wan,1 Jianjun Yang,1 Wei Hao,3 Yaxian Wang,3 Jinrong Yao,3 Zhengzhong Shao,3 Peng Zhang,1 Jun Chen,1 Liang Zhou,4 Shiyi Chen11Fudan University Sports Medicine Center and Department of Sports Medicine and Arthroscopy Surgery, Huashan Hospital, 2State Key Laboratory of Molecular Engineering of Polymers, 3Laboratory of Advanced Materials, National Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, People’s Republic of China; 4Department of Forest Products, Anhui Agricultural University, Hefei Anhui Province, People’s Republic of ChinaBackground: Application of artificial ligament in anterior cruciate ligament reconstruction is one of the research focuses of sports medicine but the biological tendon–bone healing still remains a problem. The preliminary study of hydroxyapatite (HAP coating on the polyethylene terephthalate (PET surface could effectively induce the osteoblast differentiation, but the tendon–bone healing was still not stable. As a green synthesis process, the biomimetic mineralization can simulate the natural bone growth in vitro and in vivo.Methods: HAP crystals were grown under the guide of silk fibroin (SF PET surface by biomimetic route. Several techniques including scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy were utilized for proving the introduction of both SF and HAP. The viability and osseointegration of bone marrow stromal cells on the surface of three kinds of ligament, including PET group (non-coating group, PET+SF group (SF-coating group, and PET+SF+HAP group (combined HAP- and SF-coating group, were analyzed by CCK-8 assays and alkaline phosphatase (ALP detection. Seventy-two mature male New Zealand rabbits were randomly divided into three groups. Among them, 36 rabbits were sacrificed for mechanical testing, and

  8. Tissue Engineering Strategies in Ligament Regeneration

    Directory of Open Access Journals (Sweden)

    Caglar Yilgor

    2012-01-01

    Full Text Available Ligaments are dense fibrous connective tissues that connect bones to other bones and their injuries are frequently encountered in the clinic. The current clinical approaches in ligament repair and regeneration are limited to autografts, as the gold standard, and allografts. Both of these techniques have their own drawbacks that limit the success in clinical setting; therefore, new strategies are being developed in order to be able to solve the current problems of ligament grafting. Tissue engineering is a novel promising technique that aims to solve these problems, by producing viable artificial ligament substitutes in the laboratory conditions with the potential of transplantation to the patients with a high success rate. Direct cell and/or growth factor injection to the defect site is another current approach aiming to enhance the repair process of the native tissue. This review summarizes the current approaches in ligament tissue engineering strategies including the use of scaffolds, their modification techniques, as well as the use of bioreactors to achieve enhanced regeneration rates, while also discussing the advances in growth factor and cell therapy applications towards obtaining enhanced ligament regeneration.

  9. Lars von Triers film

    DEFF Research Database (Denmark)

    Nielsen, Lisbeth Overgaard

    2007-01-01

    Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse.......Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse....

  10. Euroopa majanduste andunud vikatimees Lars Christensen / Piret Reiljan

    Index Scriptorium Estoniae

    Reiljan, Piret, 1983-

    2007-01-01

    Danske Banki vanemanalüütik Lars Christensen on kahtluse alla seadnud Eesti valuutakomitee süsteemi püsimise. Vt. samas: Lars Christensen; Valik Lars Christenseni tänavusi hävitavaid hinnanguid Euroopa murelastele; Islandile kuulutatud häving kukutas otsemaid aktsiaid ja valuutat. Kommenteerivad Lars Rasmussen, Flemming Christensen ja Hanna Strandgaard

  11. LAr instrumentation for Gerda phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently the commissioning of Gerda Phase II is ongoing. To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  12. Clinical, biomechanical and morphological assessment of anterior cruciate ligament Kevlar®-based artificial prosthesis in rabbit model.

    Science.gov (United States)

    de la Garza-Castro, Santiago; González-Rivera, Carlos E; Vílchez-Cavazos, Félix; Morales-Avalos, Rodolfo; Barrera-Flores, Francisco J; Elizondo-Omaña, Rodrigo E; Soto-Dominguez, Adolfo; Acosta-Olivo, Carlos; Mendoza-Lemus, Oscar F

    2017-07-27

    The aim of this study was to evaluate the clinical, biomechanical and morphological characteristics of a Kevlar®-based prosthetic ligament as a synthetic graft of the anterior cruciate ligament (ACL) in an experimental animal model in rabbits. A total of 27 knees of rabbits randomly divided into 3 groups (control, ACL excision and ACL replacement with a Kevlar® prosthesis) were analyzed using clinical, biomechanical and morphological tests at 6, 12 and 18 weeks postprocedure. The mean displacement in mechanical testing was 0.73 ± 0.06 mm, 1.58 ± 0.19 mm and 0.94 ± 0.20 mm for the control, ACL excision and ACL replacement with synthetic prosthesis groups, respectively. The results showed an improvement in the stability of the knee with the use of the Kevlar® synthetic prosthesis in the biomechanical testing (p0.05), between the replacement group and the control group. The histological study revealed a good morphological adaptation of the synthetic material to the knee. This study proposes a new animal model for the placement and evaluation of Kevlar®-based synthetic ACL implants. The studied prosthesis showed promising behavior in the clinical and biomechanical tests and in the histological analysis. This study lays the foundation for further basic and clinical studies of artificial ACL prostheses using this material.

  13. Emergent Synapse Organizers: LAR-RPTPs and Their Companions.

    Science.gov (United States)

    Han, K A; Jeon, S; Um, J W; Ko, J

    2016-01-01

    Leukocyte common antigen-related receptor tyrosine phosphatases (LAR-RPTPs) have emerged as key players that organize various aspects of neuronal development, including axon guidance, neurite extension, and synapse formation and function. Recent research has highlighted the roles of LAR-RPTPs at neuronal synapses in mediating distinct synaptic adhesion pathways through interactions with a host of extracellular ligands and in governing a variety of intracellular signaling cascades through binding to various scaffolds and signaling proteins. In this chapter, we review and update current research progress on the extracellular ligands of LAR-RPTPs, regulation of their extracellular interactions by alternative splicing and heparan sulfates, and their intracellular signaling machineries. In particular, we review structural insights on complexes of LAR-RPTPs with their various ligands. These studies lend support to general molecular mechanisms underlying LAR-RPTP-mediated synaptic adhesion and signaling pathways. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Yapay Sinir Ağları ile Web İçeriklerini Sınıflandırma / Web Content Classification Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Esra Nergis Güven

    2008-04-01

    Full Text Available [Turkish abstract]Internet’in hızlı gelişmesi ve yaygınlaşması elektronik ortamda iş ve işlemleri hızlandırmış ve kolaylaştırmıştır. Elektronik ortamlarda depolanan, taşınan ve işlenen bilgilerin boyutunun her geçen gün artması ise bilgiye erişim ile ilgili birçok problemi de beraberinde getirmiştir. Kullanıcıların elektronik ortamda sunulan bilgilere erişmelerindeki hız ve doğruluk gereksinimi nedeniyle, bu ortamlarda tutulan bilgileri sınıflandırma ve kategorilere ayırma yaklaşımlarına ihtiyaç duyulmaktadır. Sayıları milyonun üzerinde olan arama motorlarının, kullanıcıların doğru bilgilere kısa sürede ulaşmasını sağlaması için her geçen gün yeni yaklaşımlar ile desteklenmesi gerekmektedir. Bu çalışmada, web sayfalarının belirlenen konulara göre sınıflandırılabilmesi için, Çok Katmanlı (MLP yapay sinir ağı modeli kullanılmıştır. Özellik vektörü içeriğinin seçimi, yapay sinir ağının eğitilmesi ve son olarak web sayfalarının doğru kategorize edilmesi için bir yazılım geliştirilmiştir. Bu zeki yaklaşımın, elektronik ortamlarda bilgilerin kolaylıkla ve yüksek doğrulukla sınıflandırılması, web ortamlarında doğru içeriğe ulaşılması ve birçok güvenlik açığının giderilmesine katkılar sağlayacağı değerlendirilmektedir. [English abstract]Recent developments and widespread usage of the Internet have made business and processes to be completed faster and easily in electronic media. The increasing size of the stored, transferred and processed data brings many problems that affect access to information on the Web. Because of users’ need get to access to the information in electronic environment quickly, correctly and appropriately, different methods of classification and categorization of data are strictly needed. Millions of search engines should be supported with new approaches every day in order for users to get access to

  15. Ultrastructure of periprosthetic Dacron knee ligament tissue. Two cases of ruptured anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Salvi, M; Velluti, C; Misasi, M; Bartolozzi, P; Quacci, D; Dell'Orbo, C

    1991-04-01

    Light- and electron-microscopic investigations were performed on two failed Dacron ligaments that had been removed from 2 patients shortly after failure of the implant 2-3 years after reconstruction of the anterior cruciate ligament. Two different cell populations and matrices were correlated with closeness to the Dacron threads. Fibroblasts surrounded by connective tissue with collagen fibrils were located far from the Dacron threads. Roundish cells, appearing to be myofibroblasts surrounded by a more lax connective tissue and elastic fibers, were found close to the Dacron threads. The presence of myofibroblasts and the matrix differentiation could be attributed to the different mechanical forces acting on the Dacron and on the connective tissue because of their different coefficients of elasticity. The sparse occurrence of inflammatory cells in the synovial membrane and in the connective tissue surrounding the Dacron supports the biologic inertness of this artificial material. However, the repair tissue was not structured to resist tension stresses.

  16. Enformasyon Toplumunun Suçluları: “Hacker”lar

    OpenAIRE

    Emre Kaya, Ayşe Elif

    2018-01-01

    Bu çalışmada, 1960’lı yıllarda araştırmacılar tarafından ortaya konan enformasyon toplumu projeleri ile aynı dönemde ortaya çıkan “hacker”lar ve “hacker”ların suça yöneliş nedenleri üzerinde durulmaktadır. Çalışmada, enformasyon projeleri ve ona kar- şılık sunulan eleştiriler ortaya konularak, “hacker”ların eylemlerinin enformasyon toplumu projelerine yönelik bir eleştiriyi içlerinde barındırıp barındırmadıkları sorusu araştırılmıştır. Kapsamı bu şekilde be...

  17. The Liquid Annular Reactor System (LARS) propulsion

    International Nuclear Information System (INIS)

    Powell, J.; Ludewig, H.; Horn, F.; Lenard, R.

    1990-01-01

    A concept for very high specific impulse (greater than 2000 seconds) direct nuclear propulsion is described. The concept, termed the liquid annular reactor system (LARS), uses liquid nuclear fuel elements to heat hydrogen propellant to very high temperatures (approximately 6000 K). Operating pressure is moderate (approximately 10 atm), with the result that the outlet hydrogen is virtually 100 percent dissociated to monatomic H. The molten fuel is contained in a solid container of its own material, which is rotated to stabilize the liquid layer by centripetal force. LARS reactor designs are described, together with neutronic and thermal-hydraulic analyses. Power levels are on the order of 200 megawatts. Typically, LARS designs use seven rotating fuel elements, are beryllium moderated, and have critical radii of approximately 100 cm (core L/D approximately equal to 1.5)

  18. ICARUS An Innovative Large LAR Detector for Neutrino Physics

    CERN Document Server

    Vignoli, C; Disdier, J.M.; Rampoldi, D.; Passardi, G.

    2006-01-01

    ICARUS is an international project that foresees the installation of very large LAr detectors inside the Gran Sasso underground laboratory in order to be sensitive to rare phenomena of particle physics. The detection technique is based on the collection of electrons produced by particle interactions in LAr by a matrix of thousands of thin wires. At the moment the project foresees the installation of a 600,000‐kg vessel (T600). The total amount of LAr can be expanded in a modular way to masses of the order of 106 kg. The T600 houses two identical 300,000‐kg Ar sub‐cryostats that are aluminum boxes about 20‐m long, 4‐m high and 4‐m wide. Safety requirements for the underground installation have led to a unique design for the vessels to prevent LAr spillages even in the case of inner cryostat failure. Electrons must drift over meters requiring the development of special gas and liquid Ar purification units to provide an extremely high LAr purity (better then 0.1 ppb). The cooling system has been desi...

  19. Arthroscopic procedures and therapeutic results of anatomical reconstruction of the coracoclavicular ligaments for acromioclavicular Joint dislocation.

    Science.gov (United States)

    Takase, K; Yamamoto, K

    2016-09-01

    Surgical treatment is recommended for type 5 acromioclavicular joint dislocation on Rockwood's classification. We believe that anatomic repair of the coracoclavicular ligaments best restores the function of the acromioclavicular joint. We attempted to correctly reconstruct the anatomy of the coracoclavicular ligaments under arthroscopy, and describe the minimally invasive arthroscopic procedure. There were 22 patients; mean age at surgery, 38.1 years. Mean time to surgery was 13.2 days. Mean follow-up was 3 years 2 months. The palmaris longus tendon was excised from the ipsilateral side to replace the conoid ligament, while artificial ligament was used for reconstructing the trapezoid ligament. Both ligament reconstructions were performed arthroscopically. No temporary fixation of the acromioclavicular joint was performed. On postoperative radiographic evaluation, 4 patients showed subluxation and 2 showed dislocation of the acromioclavicular joint; the other 16 patients had maintained reduction at the final consultation. MR images 1year after surgery clearly revealed the reconstructed ligaments in 19 patients. Only 1 patient showed osteoarthritis of the acromioclavicular joint. Although it requires resection of the ipsilateral palmaris longus for grafting, we believe that anatomic reconstruction of both coracoclavicular ligaments best restores the function of the acromioclavicular joint. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Ülar Mark: loome uut ja iga loomisega lammutame midagi / Ülar Mark ; intervjueerinud Mikk Salu

    Index Scriptorium Estoniae

    Mark, Ülar, 1968-

    2010-01-01

    Eesti Arhitektuurikeskuse juhatuse esimees, arhitekt Ülar Mark Tallinna arhitektuurist ja linna arengust, demokraatlikust linnaruumist. Pikemalt Solarise keskusest, vabadussambast, väikepoodide asemele suurte kaubanduskeskuste tulekust

  1. Tissue-engineered collateral ligament composite allografts for scapholunate ligament reconstruction: an experimental study.

    Science.gov (United States)

    Endress, Ryan; Woon, Colin Y L; Farnebo, Simon J; Behn, Anthony; Bronstein, Joel; Pham, Hung; Yan, Xinrui; Gambhir, Sanjiv S; Chang, James

    2012-08-01

    In patients with chronic scapholunate (SL) dissociation or dynamic instability, ligament repair is often not possible, and surgical reconstruction is indicated. The ideal graft ligament would recreate both anatomical and biomechanical properties of the dorsal scapholunate ligament (dorsal SLIL). The finger proximal interphalangeal joint (PIP joint) collateral ligament could possibly be a substitute ligament. We harvested human PIP joint collateral ligaments and SL ligaments from 15 cadaveric limbs. We recorded ligament length, width, and thickness, and measured the biomechanical properties (ultimate load, stiffness, and displacement to failure) of native dorsal SLIL, untreated collateral ligaments, decellularized collateral ligaments, and SL repairs with bone-collateral ligament-bone composite collateral ligament grafts. As proof of concept, we then reseeded decellularized bone-collateral ligament-bone composite grafts with green fluorescent protein-labeled adipo-derived mesenchymal stem cells and evaluated them histologically. There was no difference in ultimate load, stiffness, and displacement to failure among native dorsal SLIL, untreated and decellularized collateral ligaments, and SL repairs with tissue-engineered collateral ligament grafts. With pair-matched untreated and decellularized scaffolds, there was no difference in ultimate load or stiffness. However, decellularized ligaments revealed lower displacement to failure compared with untreated ligaments. There was no difference in displacement between decellularized ligaments and native dorsal SLIL. We successfully decellularized grafts with recently described techniques, and they could be similarly reseeded. Proximal interphalangeal joint collateral ligament-based bone-collateral ligament-bone composite allografts had biomechanical properties similar to those of native dorsal SLIL. Decellularization did not adversely affect material properties. These tissue-engineered grafts may offer surgeons another

  2. Performance of the LAr scintillation veto of GERDA Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Technische Universitaet Muenchen, Physik Dept. E15, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda is upgraded to Phase II. To reach the aspired background index of ≤ 10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  3. Ligament Tissue Engineering

    OpenAIRE

    Khan, Wasim Sardar

    2016-01-01

    Ligaments are commonly injured in the knee joint, and have a poor capacity for healing due to their relative avascularity. Ligament reconstruction is well established for injuries such as anterior cruciate ligament rupture, however the use of autografts and allografts for ligament reconstruction are associated with complications, and outcomes are variable. Ligament tissue engineering using stem cells, growth factors and scaffolds is a novel technique that has the potential to provide an unlim...

  4. Three-dimensional Imaging for Large LArTPCs

    Energy Technology Data Exchange (ETDEWEB)

    Chao, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Qian, X. [Brookhaven National Lab. (BNL), Upton, NY (United States); Viren, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Diwan, M. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-12-14

    High-performance event reconstruction is critical for current and future massive liquid argon time projection chambers (LArTPCs) to realize their full scientic potential. LArTPCs with readout using wire planes provides a limited number of 2D projections. In general, without a pixel-type readout it is challenging to achieve unambiguous 3D event reconstruction. As a remedy, we present a novel 3D imaging method, Wire-Cell, which incorporates the charge and sparsity information in addition to the time and geometry through simple and robust mathematics.

  5. [Imaging of alloplastic ligament implant. An in vivo and in vitro study exemplified by Kevlar].

    Science.gov (United States)

    Wening, J V; Katzer, A; Nicolas, V; Hahn, M; Jungbluth, K H; Kratzer A [corrected to Katzer, A

    1994-04-01

    Neither native X-ray nor CT or NMR allow to evaluate intraarticular implantation results of Kevlar -49 directly. In animal trials, the course of an artificial ligament may only be presumed from connective tissue ingrowth. Although soft tissue structure appears much better in NMR than in CT, direct proof of ligament continuity is still impossible. As soon as the connective tissue becomes continuous, it appears clearly and allows indirect evaluation of the prosthesis, as integrity can be judged by its shape like in natural cruciate ligament. Anatomic preparations show that connective tissue fills up the small space between the two cords of a Kevlar -49 two bundle prosthesis eight weeks after implantation, so that imaging systems show only one intraarticular bundle.

  6. Performance of the LAr scintillation veto of Gerda Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda has been upgraded to Phase II. To reach the aspired background index of ∝10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium detectors, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during Phase II start-up is reported.

  7. Ultrasonography of ankle ligaments

    International Nuclear Information System (INIS)

    Peetrons, P.A.; Silvestre, A.; Cohen, M.; Creteur, V.

    2002-01-01

    The lateral collateral ligament of the ankle is a complex of 3 ligaments: The anterior and posterior talofibular ligaments and the calcaneofibular ligament; these ligaments work together to support the lateral aspect of the ankle. The anterior talofibular (ATF) ligament (Fig. 1) runs from the anterior of the talus. The probe is placed in a slightly oblique position from the malleolus toward the forefoot. The ligament is hyperechoic when its fibres are perpendicular to the ultrasound beam (anisotropy artifact is present in ligaments as well as in tendons). It is approximately 2 mm thick and, during examination, must be straight and tight from one insertion point to the other, as seen in Fig. 2. The posterior talofibular (PTF) ligament, which runs from the posterior part of the malleolus to the posterior part of the talus, is difficult to see on US, being partially or sometimes completely hidden by the malleolus. The calcaneofibular ligament forms the middle portion of the lateral collateral ligament. It is tight between the inferior part of the lateral malleolus and the calcaneus, and runs in a slightly posterior oblique direction toward the heel (Fig. 3). The ligament lies on the deep surface of the fibular tendons, forming a hammock to fall deep on the calcaneus surface (Fig. 4). The calcaneofibular ligament is approximately 2-3 nun thick and is hyperechoic in the distal two-thirds only because of the obliquity of the proximal part. When examining this ligament, it is mandatory that the ankle be flexed dorsally; this stretches the ligament so that it can be seen clearly. (author)

  8. LArSoft: toolkit for simulation, reconstruction and analysis of liquid argon TPC neutrino detectors

    Science.gov (United States)

    Snider, E. L.; Petrillo, G.

    2017-10-01

    LArSoft is a set of detector-independent software tools for the simulation, reconstruction and analysis of data from liquid argon (LAr) neutrino experiments The common features of LAr time projection chambers (TPCs) enable sharing of algorithm code across detectors of very different size and configuration. LArSoft is currently used in production simulation and reconstruction by the ArgoNeuT, DUNE, LArlAT, MicroBooNE, and SBND experiments. The software suite offers a wide selection of algorithms and utilities, including those for associated photo-detectors and the handling of auxiliary detectors outside the TPCs. Available algorithms cover the full range of simulation and reconstruction, from raw waveforms to high-level reconstructed objects, event topologies and classification. The common code within LArSoft is contributed by adopting experiments, which also provide detector-specific geometry descriptions, and code for the treatment of electronic signals. LArSoft is also a collaboration of experiments, Fermilab and associated software projects which cooperate in setting requirements, priorities, and schedules. In this talk, we outline the general architecture of the software and the interaction with external libraries and detector-specific code. We also describe the dynamics of LArSoft software development between the contributing experiments, the projects supporting the software infrastructure LArSoft relies on, and the core LArSoft support project.

  9. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    Science.gov (United States)

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  10. ARIADNE, a Photographic LAr TPC at the CERN Neutrino Platform

    CERN Document Server

    Mavrokoridis, K; Nessi, M; Roberts, A; Smith, N A; Touramanis, C; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2016-01-01

    This letter of intent describes a novel and innovative two-phase LAr TPC with photographic capabilities as an attractive alternative readout method to the currently accepted segmented THGEMs which will require many thousands of charge readout channels for kton-scale two-phase TPCs. These colossal LAr TPCs will be used for the future long-baseline-neutrino-oscillation experiments. Optical readout also presents many other clear advantages over current readout techniques such as ease of scalability, upgrade, installation and maintenance, and cost effectiveness. This technology has already been demonstrated at the Liverpool LAr facility with the photographic capturing of cosmic muon tracks and single gammas using a 40-litre prototype. We have now secured ERC funding to develop this further with the ARIADNE programme. ARIADNE will be a 1-ton two-phase LAr TPC utilizing THGEM and EMCCD camera readouts in order to photograph interactions, allowing for track reconstruction and particle identification. We are request...

  11. Engineering the bone-ligament interface using polyethylene glycol diacrylate incorporated with hydroxyapatite.

    Science.gov (United States)

    Paxton, Jennifer Z; Donnelly, Kenneth; Keatch, Robert P; Baar, Keith

    2009-06-01

    Ligaments and tendons have previously been tissue engineered. However, without the bone attachment, implantation of a tissue-engineered ligament would require it to be sutured to the remnant of the injured native tissue. Due to slow repair and remodeling, this would result in a chronically weak tissue that may never return to preinjury function. In contrast, orthopaedic autograft reconstruction of the ligament often uses a bone-to-bone technique for optimal repair. Since bone-to-bone repairs heal better than other methods, implantation of an artificial ligament should also occur from bone-to-bone. The aim of this study was to investigate the use of a poly(ethylene glycol) diacrylate (PEGDA) hydrogel incorporated with hydroxyapatite (HA) and the cell-adhesion peptide RGD (Arg-Gly-Asp) as a material for creating an in vitro tissue interface to engineer intact ligaments (i.e., bone-ligament-bone). Incorporation of HA into PEG hydrogels reduced the swelling ratio but increased mechanical strength and stiffness of the hydrogels. Further, HA addition increased the capacity for cell growth and interface formation. RGD incorporation increased the swelling ratio but decreased mechanical strength and stiffness of the material. Optimum levels of cell attachment were met using a combination of both HA and RGD, but this material had no better mechanical properties than PEG alone. Although adherence of the hydrogels containing HA was achieved, failure occurs at about 4 days with 5% HA. Increasing the proportion of HA improved interface formation; however, with high levels of HA, the PEG HA composite became brittle. This data suggests that HA, by itself or with other materials, might be well suited for engineering the ligament-bone interface.

  12. Full Spectrum LAR

    Science.gov (United States)

    2008-01-01

    Emerson 901 TOW Under Armor (TUA) weapons system. When reliably operational, the Emerson 901 turret can still provide effective anti-armor fires as...the rear of the LAV-R thus there is no available space to carry ammunition resupplies, food, or under armor ambulance kits. On the other hand, the...the LAR battalion; however, the LAV-EFSS cannot be fired under armor protection or in the direct firing mode. Both the LAV-120 AMS and the LAV-EFSS

  13. ICARUS: An Innovative Large LAR Detector for Neutrino Physics

    Science.gov (United States)

    Vignoli, C.; Barni, D.; Disdier, J. M.; Rampoldi, D.; Icarus Collaboration

    2006-04-01

    ICARUS is an international project that foresees the installation of very large LAr detectors inside the Gran Sasso underground laboratory in order to be sensitive to rare phenomena of particle physics. The detection technique is based on the collection of electrons produced by particle interactions in LAr by a matrix of thousands of thin wires. At the moment the project foresees the installation of a 600,000-kg vessel (T600). The total amount of LAr can be expanded in a modular way to masses of the order of 106 kg. The T600 houses two identical 300,000-kg Ar sub-cryostats that are aluminum boxes about 20-m long, 4-m high and 4-m wide. Safety requirements for the underground installation have led to a unique design for the vessels to prevent LAr spillages even in the case of inner cryostat failure. Electrons must drift over meters requiring the development of special gas and liquid Ar purification units to provide an extremely high LAr purity (better then 0.1 ppb). The cooling system has been designed to assure a high thermal uniformity in the detector volume (less than 1-K differential). The cryogenic system associated with the final ICARUS configuration is based on three N2 refrigerators, three 30-m3 tanks and pump driven two-phase N2 forced-flow cooling of the various sub-systems. The T600 was successfully tested in Pavia in 2001 and it is now under installation in Gran Sasso for final operation. The future mass expansion strategy is under investigation.

  14. Medial collateral ligament healing one year after a concurrent medial collateral ligament and anterior cruciate ligament injury: an interdisciplinary study in rabbits.

    Science.gov (United States)

    Yamaji, T; Levine, R E; Woo, S L; Niyibizi, C; Kavalkovich, K W; Weaver-Green, C M

    1996-03-01

    The optimal treatment for concurrent injuries to the medial collateral and anterior cruciate ligaments has not been determined, despite numerous clinical and laboratory studies. The objective of this study was to examine the effect of surgical repair of the medial collateral ligament on its biomechanical and biochemical properties 52 weeks after such injuries. In the left knee of 12 skeletally mature New Zealand White rabbits, the medial collateral ligament was torn and the anterior cruciate ligament was transected and then reconstructed. This is an experimental model previously developed in our laboratory. In six rabbits, the torn ends of the medial collateral ligament were repaired, and in the remaining six rabbits, the ligament was not repaired. Fifty-two weeks after injury, we examined varus-valgus and anterior-posterior knee stability; structural properties of the femur-medial collateral ligament-tibia complex; and mechanical properties, collagen content, and mature collagen crosslinking of the medial collateral ligament. We could not detect significant differences between repair and nonrepair groups for any biomechanical or biochemical property. Our data support clinical findings that when the medial collateral and anterior cruciate ligaments are injured concurrently and the anterior cruciate ligament is reconstructed, conservative treatment of the ruptured medial collateral ligament can result in successful healing.

  15. Extra-articular subcutaneous "inverted king post-truss" ligament reconstruction for severe swan neck deformity (snapping finger).

    Science.gov (United States)

    de Soras, X; de Mourgues, P; Pradel, P; Urien, J-P; Beaudoin, E

    2017-02-01

    A swan neck deformity (SND) can be well tolerated for a long time, until the appearance of a disabling "snapping finger". In its most advanced condition, the other hand is needed to initiate finger flexion. We propose a technique of extra-articular, subcutaneous ligament reconstruction with an "inverted king post-truss" configuration use in roofs and to reinforce railway bridges. An artificial ligament (MaxBraid™ polyethylene surgical suture, 5 metric, Biomet) makes a figure of eight between transosseous tunnels in the proximal and middle phalanges, crossing over top of the A3 pulley. We limited our series to severe SND cases with "snapping finger". We excluded isolated SNDs without functional disability. Eleven patients were followed for 3.4 years on average. The cause was an acute injury 8 times (7 balloon accidents), rheumatoid arthritis 2 times and overuse once (saxophone). Only one case was a poor outcome of mallet finger. The 11 patients were reassessed by a telephone survey. Two patients underwent reoperation: one for a ligament rupture, the other one for a knot that became untied. One patient had a suspected late rupture but without recurrence of the disabling snapping finger. The 11 patients considered themselves improved by the intervention. Nine patients did not notice any difference between their operated finger and the contralateral side. Return to manual activity was possible once the skin had healed. The technique is simpler than the spiral oblique retinacular ligament (SORL) reconstruction technique described by Thomson-Littler and also less demanding because it does not involve the distal interphalangeal joint. It requires only a short incision in the volar crease of the proximal interphalangeal joint. No tendon or ligament is sacrificed. Neither postoperative immobilization nor lengthy physical therapy is needed. Complications can be avoided by selecting the appropriate artificial ligament material and careful knot tying. Copyright © 2016 SFCM

  16. MRI appearance of surgically proven abnormal accessory anterior-inferior tibiofibular ligament (Bassett's ligament)

    International Nuclear Information System (INIS)

    Subhas, Naveen; Vinson, Emily N.; Cothran, R.L.; Helms, Clyde A.; Santangelo, James R.; Nunley, James A.

    2008-01-01

    A thickened accessory anterior-inferior tibiofibular ligament (Bassett's ligament) of the ankle can be a cause of ankle impingement. Its imaging appearance is not well described. The purpose of this study was to determine if the ligament could be identified on magnetic resonance imaging (MRI), to determine associated abnormalities, and to determine if MRI could be used to differentiate normal from abnormal. Eighteen patients with a preoperative ankle MRI and an abnormal Bassett's ligament reported at surgery were found retrospectively. A separate cohort of 18 patients was selected as a control population. The presence of Bassett's ligament and its thickness were noted. The integrity and appearance of the lateral ankle ligaments, talar dome cartilage, and anterolateral gutter were also noted. In 34 of the 36 cases (94%), Bassett's ligament was identified on MRI. The ligament was seen in all three imaging planes and most frequently in the axial plane. The mean thickness of the ligament in the surgically abnormal cases was 2.37 mm, compared with 1.87 mm in the control with a p value = 0.015 (t test). Nine of the 18 abnormal cases (50%) had talar dome cartilage lesions as a result of contact with the ligament at surgery, with only 3 cases of high-grade defects seen on MRI. Fourteen of the 18 abnormal cases (78%) had of synovitis or scarring in the lateral gutter at surgery, with only 5 cases with scarring seen on MRI. The anterior-inferior tibiofibular ligament was abnormal or torn in 8 of the 18 abnormal cases (44%) by MRI and confirmed in only 3 cases at surgery. Bassett's ligament can be routinely identified on MRI and was significantly thicker in patients who had it resected at surgery. An abnormal Bassett's ligament is often present in the setting of a normal anterior-inferior tibiofibular ligament. The cartilage abnormalities and synovitis associated with an abnormal Bassett's ligament are poorly detected by conventional MRI. (orig.)

  17. Influence of LAR and VAR on Para-Aminopyridine Antimalarials Targetting Haematin in Chloroquine-Resistance.

    Science.gov (United States)

    Warhurst, David C; Craig, John C; Raheem, K Saki

    2016-01-01

    Antimalarial chloroquine (CQ) prevents haematin detoxication when CQ-base concentrates in the acidic digestive vacuole through protonation of its p-aminopyridine (pAP) basic aromatic nitrogen and sidechain diethyl-N. CQ export through the variant vacuolar membrane export channel, PFCRT, causes CQ-resistance in Plasmodium falciparum but 3-methyl CQ (sontochin SC), des-ethyl amodiaquine (DAQ) and bis 4-aminoquinoline piperaquine (PQ) are still active. This is determined by changes in drug accumulation ratios in parasite lipid (LAR) and in vacuolar water (VAR). Higher LAR may facilitate drug binding to and blocking PFCRT and also aid haematin in lipid to bind drug. LAR for CQ is only 8.3; VAR is 143,482. More hydrophobic SC has LAR 143; VAR remains 68,523. Similarly DAQ with a phenol substituent has LAR of 40.8, with VAR 89,366. In PQ, basicity of each pAP is reduced by distal piperazine N, allowing very high LAR of 973,492, retaining VAR of 104,378. In another bis quinoline, dichlorquinazine (DCQ), also active but clinically unsatisfactory, each pAP retains basicity, being insulated by a 2-carbon chain from a proximal nitrogen of the single linking piperazine. While LAR of 15,488 is still high, the lowest estimate of VAR approaches 4.9 million. DCQ may be expected to be very highly lysosomotropic and therefore potentially hepatotoxic. In 11 pAP antimalarials a quadratic relationship between logLAR and logResistance Index (RI) was confirmed, while log (LAR/VAR) vs logRI for 12 was linear. Both might be used to predict the utility of structural modifications.

  18. The appearance of a lurking ligament in Laparoscopic Sleeve Gastrectomy; Posterior Gastric Ligament

    Directory of Open Access Journals (Sweden)

    Mutlu Ünver

    2017-03-01

    Full Text Available Objective: The aim of this study was to demonstrate a lurking ligament and its various formation types and to mention the importance of this ligament in Laparoscopic sleeve gastrectomy Methods: One hundred and twelve patients had laparoscopic sleeve gastrectomy (LSG procedure in our clinic between March 2011 and September 2013. All procedures were performed with a standard operative technique. Only difference for the last 50 patients was to avoid the excessive dissection of posterior gastric wall. The existence of posterior gastric ligament was recorded and different types of posterior gastric ligament was demonstrated. Results: Posterior gastric ligament was observed in all of the cases in different formation types. Three types of ligament; complete, partial and skippy, was demonstrated. 53(47.3% of the patients had skippy, while 41 (36.6% had partial and 18 (16.1% had complete type of posterior gastric ligament. Conclusion: A ligament named as ‘posterior gastric ligament’ and its various forms were defined in the third dimensional plane of stomach. Posterior gastric ligament remains as the only structure in LSG for preventing the mobility and ability of the stomach to rotate. The excessive dissection of the posterior gastric ligament should be avoided to prevent complications such as kinking and volvulus

  19. Land-Acquisition and Resettlement (LAR Conflicts: A Perspective of Spatial Injustice of Urban Public Resources Allocation

    Directory of Open Access Journals (Sweden)

    Jinxia Zhu

    2018-03-01

    Full Text Available Land acquisition and resettlement (LAR is an important step in urban development. As one of the ‘externalities of development’, LAR conflicts have affected social stability and development in rural areas of China. With social conflict research shifting from value identity to resource allocation, few studies have examined the relationship between the spatial injustice of urban public resources and LAR conflict. To mitigate this research gap and formulate effective policies, this study aims to reinterpret the obstacles of LAR conflicts from the perspective of the spatial injustice of urban public facilities allocation in Hangzhou City by examining 195 administrative litigation cases. Spatial accessibility was used for estimating the spatial justice of urban public resources allocation. A classification and regression tree (CART model was applied to identify the advantage and disadvantage factors behind LAR conflict, and explored the logical and structural relationships among these factors. Results showed that a spatial mismatch between the spatial behavior preferences of human activity and the spatial injustice of urban public resources allocation had significantly accelerated LAR conflicts. When the spatial behavior preferences of human activity and spatial distribution of urban public resources correspond to each other pre- and after LAR, basic rights to social space are safeguarded and various groups can equitably share spatial resources. There are no conflicts. Conversely, respondents expressed a high level of dissatisfaction in comparison to their pre-LAR conditions, and LAR conflict undeniably occurs. This approach also proposes some good LAR policies by regulating the spatial injustice of urban public resources allocation associated with LAR with the aim of long-term urban sustainable development for Hangzhou.

  20. File list: His.Lar.50.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.50.AllAg.Larval_brain dm3 Histone Larvae Larval brain SRX1426943,SRX1426945... http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.50.AllAg.Larval_brain.bed ...

  1. File list: His.Lar.10.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.10.AllAg.Larval_brain dm3 Histone Larvae Larval brain SRX1426945,SRX1426943... http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.10.AllAg.Larval_brain.bed ...

  2. File list: His.Lar.20.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.20.AllAg.Larval_brain dm3 Histone Larvae Larval brain SRX1426943,SRX1426945... http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.20.AllAg.Larval_brain.bed ...

  3. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    Heisel, Mark

    2011-01-01

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76 Ge, by operating naked germanium detectors submersed into 65 m 3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m 3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10 3 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10 -2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42 Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  4. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  5. The Liquid Argon Software Toolkit (LArSoft): Goals, Status and Plan

    Energy Technology Data Exchange (ETDEWEB)

    Pordes, Rush [Fermilab; Snider, Erica [Fermilab

    2016-08-17

    LArSoft is a toolkit that provides a software infrastructure and algorithms for the simulation, reconstruction and analysis of events in Liquid Argon Time Projection Chambers (LArTPCs). It is used by the ArgoNeuT, LArIAT, MicroBooNE, DUNE (including 35ton prototype and ProtoDUNE) and SBND experiments. The LArSoft collaboration provides an environment for the development, use, and sharing of code across experiments. The ultimate goal is to develop fully automatic processes for reconstruction and analysis of LArTPC events. The toolkit is based on the art framework and has a well-defined architecture to interface to other packages, including to GEANT4 and GENIE simulation software and the Pandora software development kit for pattern recognition. It is designed to facilitate and support the evolution of algorithms including their transition to new computing platforms. The development of the toolkit is driven by the scientific stakeholders involved. The core infrastructure includes standard definitions of types and constants, means to input experiment geometries as well as meta and event- data in several formats, and relevant general utilities. Examples of algorithms experiments have contributed to date are: photon-propagation; particle identification; hit finding, track finding and fitting; electromagnetic shower identification and reconstruction. We report on the status of the toolkit and plans for future work.

  6. CT appearance of pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Han, Man Chung; Chin, Soo Yil [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Pulmonary ligament consists of 2 serosal of pleura that connect the lower to the mediastinum. Author analyse and present CT appearance of pulmonary ligament of the 40 normal and abnormal patients on the basis of anatomic knowledge from the cross section of cadaver. Left pulmonary ligament is more frequency visualized than the right. The most important CT landmark in localizing pulmonary ligament is the esophagus where the ligament attaches on its lateral wall. Pitfalls in CT identification of pulmonary ligament are right phrenic nerve and right pericardiacophrenic vessels which emerge from lateral wall of the IVC and wall of the emphysematous bulla in the region of the pulmonary ligament.

  7. CT appearance of pulmonary ligament

    International Nuclear Information System (INIS)

    Im, Jung Gi; Han, Man Chung; Chin, Soo Yil

    1984-01-01

    Pulmonary ligament consists of 2 serosal of pleura that connect the lower to the mediastinum. Author analyse and present CT appearance of pulmonary ligament of the 40 normal and abnormal patients on the basis of anatomic knowledge from the cross section of cadaver. Left pulmonary ligament is more frequency visualized than the right. The most important CT landmark in localizing pulmonary ligament is the esophagus where the ligament attaches on its lateral wall. Pitfalls in CT identification of pulmonary ligament are right phrenic nerve and right pericardiacophrenic vessels which emerge from lateral wall of the IVC and wall of the emphysematous bulla in the region of the pulmonary ligament

  8. File list: ALL.Lar.50.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.50.AllAg.Larval_brain dm3 All antigens Larvae Larval brain SRX1426944,SRX14...26943,SRX1426945,SRX1426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.50.AllAg.Larval_brain.bed ...

  9. File list: ALL.Lar.20.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.20.AllAg.Larval_brain dm3 All antigens Larvae Larval brain SRX1426944,SRX14...26943,SRX1426945,SRX1426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.20.AllAg.Larval_brain.bed ...

  10. File list: ALL.Lar.05.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.05.AllAg.Larval_brain dm3 All antigens Larvae Larval brain SRX1426945,SRX14...26944,SRX1426946,SRX1426943 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.05.AllAg.Larval_brain.bed ...

  11. File list: ALL.Lar.10.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.10.AllAg.Larval_brain dm3 All antigens Larvae Larval brain SRX1426945,SRX14...26944,SRX1426943,SRX1426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.10.AllAg.Larval_brain.bed ...

  12. Koda = Koda / Ülar Mark, Kariina Kristiina Kaufmann, Kadri Tonto ; kommenteerinud Katrin Koov

    Index Scriptorium Estoniae

    Mark, Ülar, 1968-

    2016-01-01

    Minimalistliku vormiga eramu KODA Tallinnas, Järvekalda tee 33. Autorid Ülar Mark, Taavi Jakobson, Hannes Tamjärv, Kalev Ramjalg, Marek Strandberg. Arhitektid Ülar Mark, Kariina Kristiina Kaufmann, Kadri Tonto, Hannes Praks

  13. File list: Oth.Lar.05.daf-12.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.05.daf-12.AllCell ce10 TFs and others daf-12 Larvae SRX146513,SRX065705,SRX...146512,SRX065706,SRX065713,SRX065714 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Oth.Lar.05.daf-12.AllCell.bed ...

  14. File list: Oth.Lar.10.daf-12.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.10.daf-12.AllCell ce10 TFs and others daf-12 Larvae SRX146513,SRX065706,SRX...065705,SRX146512,SRX065713,SRX065714 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Oth.Lar.10.daf-12.AllCell.bed ...

  15. File list: Oth.Lar.50.daf-12.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.50.daf-12.AllCell ce10 TFs and others daf-12 Larvae SRX065714,SRX065713,SRX...146512,SRX065705,SRX146513,SRX065706 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Oth.Lar.50.daf-12.AllCell.bed ...

  16. File list: Oth.Lar.20.daf-12.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.20.daf-12.AllCell ce10 TFs and others daf-12 Larvae SRX146513,SRX146512,SRX...065713,SRX065705,SRX065706,SRX065714 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Oth.Lar.20.daf-12.AllCell.bed ...

  17. Regionaalpoliitika ja arhitektuur / Ülar Mark

    Index Scriptorium Estoniae

    Mark, Ülar

    1999-01-01

    Kagu-Eesti Regionaalarengu Programmi raames Eesti Kunstiakadeemia arhitektuurikateedri IV kursuse eriala valikaines 1998/99 tehtud tööst "HyperMobiilne Reaalsus & Kagu Eesti" (juhendajad Ralf Tamm, Ülar Mark). Ühises töös osalesid Tartu Ülikooli geograafiatudengid (juhendaja Rein Ahas). 4 illustratsiooni

  18. File list: Pol.Lar.50.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.50.RNA_polymerase_III.AllCell ce10 RNA polymerase RNA polymerase III Larvae... http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Pol.Lar.50.RNA_polymerase_III.AllCell.bed ...

  19. File list: Pol.Lar.20.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.20.RNA_polymerase_III.AllCell ce10 RNA polymerase RNA polymerase III Larvae... http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Pol.Lar.20.RNA_polymerase_III.AllCell.bed ...

  20. File list: Pol.Lar.10.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.10.RNA_polymerase_III.AllCell ce10 RNA polymerase RNA polymerase III Larvae... http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Pol.Lar.10.RNA_polymerase_III.AllCell.bed ...

  1. File list: Pol.Lar.05.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.05.RNA_polymerase_III.AllCell ce10 RNA polymerase RNA polymerase III Larvae... http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Pol.Lar.05.RNA_polymerase_III.AllCell.bed ...

  2. Matlab implementation of LASSO, LARS, the elastic net and SPCA

    DEFF Research Database (Denmark)

    2005-01-01

    There are a number of interesting variable selection methods available beside the regular forward selection and stepwise selection methods. Such approaches include LASSO (Least Absolute Shrinkage and Selection Operator), least angle regression (LARS) and elastic net (LARS-EN) regression. There al...... exists a method for calculating principal components with sparse loadings. This software package contains Matlab implementations of these functions. The standard implementations of these functions are available as add-on packages in S-Plus and R....

  3. File list: Pol.Lar.05.RNA_Polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.05.RNA_Polymerase_II.AllCell ce10 RNA polymerase RNA Polymerase II Larvae h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Pol.Lar.05.RNA_Polymerase_II.AllCell.bed ...

  4. Investigation and development of the suppression methods of the {sup 42}K background in LArGe

    Energy Technology Data Exchange (ETDEWEB)

    Lubashevskiy, Alexey [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    GERDA is an ultra-low background experiment aimed for the neutrinoless double beta decay search. The search is performed using HPGe detectors operated in liquid argon (LAr). One of the most dangerous backgrounds in GERDA is the background from {sup 42}K which is a daughter isotope of cosmogenically produced {sup 42}Ar. {sup 42}K ions are collected towards to the detector by the electric field of the detector. Estimation of the background contribution and development of the suppression methods were performed in the low background test facility LArGe. For this purpose encapsulated HPGe and bare BEGe detectors were operated in 1m{sup 3} of LAr in the LArGe setup. It is equipped with scintillation veto, so particles which deposit part of their energy in LAr can be detected by 9 PMTs. In order to better understand background and to increase statistics the LAr of LArGe was spiked with specially produced {sup 42}Ar. All these investigations allowed us to estimate background contribution from {sup 42}K and demonstrate the possibility to suppress it in future measurements in GERDA Phase II.

  5. La Medea de Lars von Trier

    Directory of Open Access Journals (Sweden)

    Iratxe Fresneda Delgado

    2013-04-01

    Full Text Available El presente artículo analiza el modo en el que Lars von Trier recrea para el cine el estereotipo de Medea. Mediante el análisis fílmico de la película y apoyándose en los estudios culturales, el texto se interroga acerca de la importancia y el poder potencial del cine a la hora recuperar el antiguo mito y demostrar su vigencia. El análisis amplía horizontes para la compresión de los mecanismos que articulan el entramado de significados de la película, donde Von Trier aporta una nueva visión del arquetipo de Medea uniéndola, a la tradición pictórica del Romanticismo. Una influencia que habita en las posteriores obras del director danés, donde el paisaje, la naturaleza, se erige en elemento catalizador de las pulsiones humanas, en su cómplice y testigo.This paper explores the way that Lars von Trier’s film recreates the stereotype of Medea. Using film analysis and based on cultural studies the article asks about the importance and potential power of cinema to recover the ancient myth and show their effects. The analysis expands horizons for the understanding of the mechanisms that link the network of meanings of the film, where the author offers a new vision of Medea's archetype attaching it to the pictorial tradition tied to the Romanticism. An influence that can be seen in the later works of Lars von Trier, where the landscape, the nature, stands as a catalyst of human drives, as his accomplice and witness.

  6. Biomechanical study using fuzzy systems to quantify collagen fiber recruitment and predict creep of the rabbit medial collateral ligament.

    Science.gov (United States)

    Ali, A F; Taha, M M Reda; Thornton, G M; Shrive, N G; Frank, C B

    2005-06-01

    In normal daily activities, ligaments are subjected to repeated loads, and respond to this environment with creep and fatigue. While progressive recruitment of the collagen fibers is responsible for the toe region of the ligament stress-strain curve, recruitment also represents an elegant feature to help ligaments resist creep. The use of artificial intelligence techniques in computational modeling allows a large number of parameters and their interactions to be incorporated beyond the capacity of classical mathematical models. The objective of the work described here is to demonstrate a tool for modeling creep of the rabbit medial collateral ligament that can incorporate the different parameters while quantifying the effect of collagen fiber recruitment during creep. An intelligent algorithm was developed to predict ligament creep. The modeling is performed in two steps: first, the ill-defined fiber recruitment is quantified using the fuzzy logic. Second, this fiber recruitment is incorporated along with creep stress and creep time to model creep using an adaptive neurofuzzy inference system. The model was trained and tested using an experimental database including creep tests and crimp image analysis. The model confirms that quantification of fiber recruitment is important for accurate prediction of ligament creep behavior at physiological loads.

  7. File list: InP.Lar.10.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.10.AllAg.Larval_brain dm3 Input control Larvae Larval brain SRX1426944,SRX1...426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.10.AllAg.Larval_brain.bed ...

  8. File list: InP.Lar.50.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.50.AllAg.Larval_brain dm3 Input control Larvae Larval brain SRX1426944,SRX1...426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.50.AllAg.Larval_brain.bed ...

  9. File list: InP.Lar.05.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.05.AllAg.Larval_brain dm3 Input control Larvae Larval brain SRX1426944,SRX1...426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.05.AllAg.Larval_brain.bed ...

  10. File list: InP.Lar.20.AllAg.Larval_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.20.AllAg.Larval_brain dm3 Input control Larvae Larval brain SRX1426944,SRX1...426946 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.20.AllAg.Larval_brain.bed ...

  11. File list: InP.Lar.05.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.05.Input_control.AllCell ce10 Input control Input control Larvae SRX331089,...,SRX015099 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/InP.Lar.05.Input_control.AllCell.bed ...

  12. File list: Oth.Lar.50.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.50.AllAg.3rd_instar dm3 TFs and others Larvae 3rd instar SRX318781,SRX31878...5306 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Lar.50.AllAg.3rd_instar.bed ...

  13. Macroscopic and microscopic analysis of the thumb carpometacarpal ligaments: a cadaveric study of ligament anatomy and histology.

    Science.gov (United States)

    Ladd, Amy L; Lee, Julia; Hagert, Elisabet

    2012-08-15

    Stability and mobility represent the paradoxical demands of the human thumb carpometacarpal joint, yet the structural origin of each functional demand is poorly defined. As many as sixteen and as few as four ligaments have been described as primary stabilizers, but controversy exists as to which ligaments are most important. We hypothesized that a comparative macroscopic and microscopic analysis of the ligaments of the thumb carpometacarpal joint would further define their role in joint stability. Thirty cadaveric hands (ten fresh-frozen and twenty embalmed) from nineteen cadavers (eight female and eleven male; average age at the time of death, seventy-six years) were dissected, and the supporting ligaments of the thumb carpometacarpal joint were identified. Ligament width, length, and thickness were recorded for morphometric analysis and were compared with use of the Student t test. The dorsal and volar ligaments were excised from the fresh-frozen specimens and were stained with use of a triple-staining immunofluorescent technique and underwent semiquantitative analysis of sensory innervation; half of these specimens were additionally analyzed for histomorphometric data. Mixed-effects linear regression was used to estimate differences between ligaments. Seven principal ligaments of the thumb carpometacarpal joint were identified: three dorsal deltoid-shaped ligaments (dorsal radial, dorsal central, posterior oblique), two volar ligaments (anterior oblique and ulnar collateral), and two ulnar ligaments (dorsal trapeziometacarpal and intermetacarpal). The dorsal ligaments were significantly thicker (p histologic appearance of capsular tissue with low cellularity. The dorsal deltoid ligament complex is uniformly stout and robust; this ligament complex is the thickest morphometrically, has the highest cellularity histologically, and shows the greatest degree of sensory nerve endings. The hypocellular anterior oblique ligament is thin, is variable in its location, and

  14. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  15. File list: Oth.Lar.10.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.10.AllAg.3rd_instar dm3 TFs and others Larvae 3rd instar SRX104963,SRX10497...4971,SRX331403 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Lar.10.AllAg.3rd_instar.bed ...

  16. File list: Oth.Lar.20.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.20.AllAg.3rd_instar dm3 TFs and others Larvae 3rd instar SRX318781,SRX31878...1403,SRX495243 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Lar.20.AllAg.3rd_instar.bed ...

  17. File list: Oth.Lar.05.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.05.AllAg.3rd_instar dm3 TFs and others Larvae 3rd instar SRX104964,SRX10496...1403,SRX495243 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.Lar.05.AllAg.3rd_instar.bed ...

  18. File list: InP.Lar.20.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.20.Input_control.AllCell dm3 Input control Input control Larvae SRX040614,S...457599,SRX1426944,SRX1426946,SRX1426948 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.20.Input_control.AllCell.bed ...

  19. File list: His.Lar.05.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.05.AllAg.1st_instar dm3 Histone Larvae 1st instar SRX013088,SRX013009,SRX01...3064,SRX013044,SRX013097 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.05.AllAg.1st_instar.bed ...

  20. File list: Pol.Lar.10.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.10.AllAg.3rd_instar dm3 RNA polymerase Larvae 3rd instar SRX287908,SRX28790...7,SRX013070,SRX013082 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.10.AllAg.3rd_instar.bed ...

  1. File list: His.Lar.20.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.20.AllAg.1st_instar dm3 Histone Larvae 1st instar SRX013009,SRX013088,SRX01...3044,SRX013064,SRX013097 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.20.AllAg.1st_instar.bed ...

  2. File list: Pol.Lar.50.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.50.AllAg.3rd_instar dm3 RNA polymerase Larvae 3rd instar SRX287908,SRX28790...7,SRX013070,SRX013082 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.50.AllAg.3rd_instar.bed ...

  3. File list: ALL.Lar.50.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.50.AllAg.3rd_instar dm3 All antigens Larvae 3rd instar SRX1038029,SRX103803...SRX467060,SRX495306,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.50.AllAg.3rd_instar.bed ...

  4. File list: Pol.Lar.05.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.05.AllAg.3rd_instar dm3 RNA polymerase Larvae 3rd instar SRX287907,SRX28790...8,SRX013070,SRX013082 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.05.AllAg.3rd_instar.bed ...

  5. File list: His.Lar.50.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.50.AllAg.1st_instar dm3 Histone Larvae 1st instar SRX013009,SRX013088,SRX01...3044,SRX013064,SRX013097 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.50.AllAg.1st_instar.bed ...

  6. File list: His.Lar.10.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.10.AllAg.1st_instar dm3 Histone Larvae 1st instar SRX013088,SRX013064,SRX01...3044,SRX013009,SRX013097 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.10.AllAg.1st_instar.bed ...

  7. File list: Pol.Lar.20.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.20.AllAg.3rd_instar dm3 RNA polymerase Larvae 3rd instar SRX287908,SRX28790...7,SRX013070,SRX013082 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.20.AllAg.3rd_instar.bed ...

  8. Extrinsic wrist ligaments: prevalence of injury by magnetic resonance imaging and association with intrinsic ligament tears.

    Science.gov (United States)

    Taneja, Atul K; Bredella, Miriam A; Chang, Connie Y; Joseph Simeone, F; Kattapuram, Susan V; Torriani, Martin

    2013-01-01

    The objective of this study was to determine the prevalence of extrinsic wrist ligament injury by magnetic resonance imaging and its association with intrinsic ligament tears. We reviewed conventional magnetic resonance images performed over a 5-year period from adult patients in the setting of wrist trauma. Two musculoskeletal radiologists examined the integrity of wrist ligaments and presence of bone abnormalities. In a cohort of 75 subjects, extrinsic ligament injury was present in 75%, with radiolunotriquetral being most frequently affected (45%). Intrinsic ligament injury was present in 60%. Almost half of subjects had combined intrinsic and extrinsic ligament injury. Bone abnormalities were seen in 69%. The rate of extrinsic injury was higher in subjects with bone injury (P = 0.008). There is high prevalence of extrinsic ligament injury in the setting of wrist trauma, especially in the presence of bone abnormalities, with combined injury of intrinsic and extrinsic ligaments in about half of cases.

  9. File list: InP.Lar.05.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.05.Input_control.AllCell dm3 Input control Input control Larvae SRX645428,S...287678,SRX1426944,SRX1426946,SRX1426948,SRX1426950 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.05.Input_control.AllCell.bed ...

  10. File list: His.Lar.10.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.10.AllAg.2nd_instar dm3 Histone Larvae 2nd instar SRX013087,SRX013015,SRX01...3112,SRX013042,SRX013043,SRX013096 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.10.AllAg.2nd_instar.bed ...

  11. File list: His.Lar.05.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.05.AllAg.2nd_instar dm3 Histone Larvae 2nd instar SRX013087,SRX013096,SRX01...3043,SRX013015,SRX013112,SRX013042 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.05.AllAg.2nd_instar.bed ...

  12. File list: His.Lar.50.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.50.AllAg.2nd_instar dm3 Histone Larvae 2nd instar SRX013015,SRX013042,SRX01...3112,SRX013043,SRX013087,SRX013096 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.50.AllAg.2nd_instar.bed ...

  13. File list: His.Lar.20.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Lar.20.AllAg.2nd_instar dm3 Histone Larvae 2nd instar SRX013015,SRX013042,SRX01...3112,SRX013043,SRX013096,SRX013087 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/His.Lar.20.AllAg.2nd_instar.bed ...

  14. Ankle ligament injuries

    Directory of Open Access Journals (Sweden)

    Per A.F.H. Renström

    1998-06-01

    Full Text Available Acute ankle ligament sprains are common injuries. The majority of these occur during athletic participation in the 15 to 35 year age range. Despite the frequency of the injury, diagnostic and treatment protocols have varied greatly. Lateral ligament complex injuries are by far the most common of the ankle sprains. Lateral ligament injuries typically occur during plantar flexion and inversion, which is the position of maximum stress on the anterotalofibular liagment (ATFL. For this reason, the ATFL is the most commonly torn ligament during an inversion injury. In more severe inversion injuries the calcaneofibular (CFL, posterotalofibular (PTFL and subtalar ligament can also be injured. Most acute lateral ankle ligament injuries recover quickly with nonoperative management. The treatment program, called "functional treatment," includes application of the RICE principle (rest, ice, compression, and elevation immediately after the injury, a short period of immobilization and protection with an elastic or inelastic tape or bandage, and early motion exercises followed by early weight bearing and neuromuscular ankle training. Proprioceptive training with a tilt board is commenced as soon as possible, usually after 3 to 4 weeks. The purpose is to improve the balance and neuromuscular control of the ankle. Sequelae after ankle ligament injuries are very common. As much as 10% to 30% of patients with a lateral ligament injury may have chronic symptoms. Symptoms usually include persistent synovitis or tendinitis, ankle stiffness, swelling, and pain, muscle weakness, and frequent giving-way. A well designed physical therapy program with peroneal strengthening and proprioceptive training, along with bracing and/or taping can alleviate instability problems in most patients. For cases of chronic instability that are refractory to bracing and external support, surgical treatment can be explored. If the chronic instability is associated with subtalar instability

  15. Twentyfourth Podcast - Interview with Lars Holmgaard Christensen

    DEFF Research Database (Denmark)

    2008-01-01

    Every wednesday the Doctoral School of Human Centred Informatics hosts a small research seminar, where PhD students and senior researchers can share and discuss their ongoing work. Today, we bring an interview from spring 2008. On February 27, Lars Holmgaard Christensen presented his paper "Homo...

  16. File list: ALL.Lar.10.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.10.AllAg.1st_instar dm3 All antigens Larvae 1st instar SRX013088,SRX013064,...SRX013044,SRX013009,SRX013072,SRX013097,SRX013055,SRX013056 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.10.AllAg.1st_instar.bed ...

  17. File list: ALL.Lar.50.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.50.AllAg.1st_instar dm3 All antigens Larvae 1st instar SRX013009,SRX013072,...SRX013088,SRX013044,SRX013064,SRX013097,SRX013056,SRX013055 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.50.AllAg.1st_instar.bed ...

  18. File list: ALL.Lar.20.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.20.AllAg.1st_instar dm3 All antigens Larvae 1st instar SRX013009,SRX013072,...SRX013088,SRX013044,SRX013064,SRX013097,SRX013055,SRX013056 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.20.AllAg.1st_instar.bed ...

  19. File list: ALL.Lar.05.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.05.AllAg.3rd_instar dm3 All antigens Larvae 3rd instar SRX104964,SRX104963,...SRX287718,SRX331401,SRX287658,SRX331366,SRX287906,SRX287678 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.05.AllAg.3rd_instar.bed ...

  20. File list: ALL.Lar.10.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.10.AllAg.3rd_instar dm3 All antigens Larvae 3rd instar SRX104963,SRX104968,...SRX287718,SRX022334,SRX104976,SRX467107,SRX013086,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.10.AllAg.3rd_instar.bed ...

  1. File list: ALL.Lar.20.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.20.AllAg.3rd_instar dm3 All antigens Larvae 3rd instar SRX1038029,SRX103803...SRX013082,SRX467107,SRX016173,SRX215499,SRX495243,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.20.AllAg.3rd_instar.bed ...

  2. File list: ALL.Lar.05.AllAg.1st_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.05.AllAg.1st_instar dm3 All antigens Larvae 1st instar SRX013088,SRX013009,...SRX013064,SRX013044,SRX013072,SRX013055,SRX013097,SRX013056 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.05.AllAg.1st_instar.bed ...

  3. File list: Unc.Lar.50.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Lar.50.AllAg.3rd_instar dm3 Unclassified Larvae 3rd instar SRX1038029,SRX103803...1,SRX1038032,SRX1038030,SRX022335,SRX032124,SRX032123,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Lar.50.AllAg.3rd_instar.bed ...

  4. File list: Oth.Lar.20.Adenine_N6-methylation.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Lar.20.Adenine_N6-methylation.AllCell ce10 TFs and others Adenine N6-methylatio...n Larvae http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/assembled/Oth.Lar.20.Adenine_N6-methylation.AllCell.bed ...

  5. Rupture of the meniscofibular ligament

    Directory of Open Access Journals (Sweden)

    Poyanli Oguz

    2010-05-01

    Full Text Available Abstract The meniscofibular ligament is an anatomically defined ligament of the knee in humans. However, there are no data regarding the prognosis following injury to this ligament. Our case was a 42-year-old man who presented at our clinic with pain of the lateral side of his left knee. MRI of his left knee revealed the rupture of the meniscofibular ligament. The mechanism of injury was consistent with anatomical and mechanical studies of the meniscofibular ligament. The patient was treated conservatively for 1 year, but his pain did not resolve completely. A case series of patients with the same injury is required to establish an effective treatment for this rare injury.

  6. File list: Pol.Lar.05.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.05.RNA_polymerase_II.AllCell dm3 RNA polymerase RNA polymerase II Larvae SR...SRX151962,SRX182775,SRX661503,SRX013070,SRX013072,SRX013113,SRX013082,SRX151961 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.05.RNA_polymerase_II.AllCell.bed ...

  7. File list: Pol.Lar.20.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Lar.20.RNA_polymerase_II.AllCell dm3 RNA polymerase RNA polymerase II Larvae SR...SRX661503,SRX026742,SRX013070,SRX013072,SRX182775,SRX151961,SRX013082,SRX013113 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Pol.Lar.20.RNA_polymerase_II.AllCell.bed ...

  8. File list: Unc.Lar.10.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Lar.10.AllAg.3rd_instar dm3 Unclassified Larvae 3rd instar SRX1038029,SRX103803...1,SRX1038032,SRX1038030,SRX032124,SRX032123,SRX022335,SRX022334,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Lar.10.AllAg.3rd_instar.bed ...

  9. File list: ALL.Lar.05.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.05.AllAg.2nd_instar dm3 All antigens Larvae 2nd instar SRX013087,SRX013096,...SRX013043,SRX013015,SRX013112,SRX013042,SRX013113,SRX013016,SRX013114 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.05.AllAg.2nd_instar.bed ...

  10. File list: ALL.Lar.50.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.50.AllAg.2nd_instar dm3 All antigens Larvae 2nd instar SRX013015,SRX013042,...SRX013112,SRX013016,SRX013114,SRX013043,SRX013087,SRX013096,SRX013113 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.50.AllAg.2nd_instar.bed ...

  11. File list: ALL.Lar.20.AllAg.2nd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Lar.20.AllAg.2nd_instar dm3 All antigens Larvae 2nd instar SRX013015,SRX013042,...SRX013112,SRX013043,SRX013016,SRX013114,SRX013096,SRX013087,SRX013113 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/ALL.Lar.20.AllAg.2nd_instar.bed ...

  12. File list: Unc.Lar.20.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Lar.20.AllAg.3rd_instar dm3 Unclassified Larvae 3rd instar SRX1038029,SRX103803...1,SRX1038032,SRX1038030,SRX022335,SRX032124,SRX022334,SRX032123,SRX013058 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Lar.20.AllAg.3rd_instar.bed ...

  13. File list: Unc.Lar.05.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Lar.05.AllAg.3rd_instar dm3 Unclassified Larvae 3rd instar SRX1038031,SRX103802...9,SRX1038032,SRX1038030,SRX022335,SRX022334,SRX032124,SRX013058,SRX032123 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Unc.Lar.05.AllAg.3rd_instar.bed ...

  14. Samsun’da Ağır Ceza Mahkemesine Yansıyan Cinsel Suçlar

    Directory of Open Access Journals (Sweden)

    Berna Aydın

    2004-04-01

    Full Text Available Çalışmamızda cinsel suçların karakteristik özelliklerini belirlemek ve Türk Ceza Kanunu (TCK’nda yapılan değişiklikler çerçevesinde, cinsel suçlarla ilgili ortaya çıkan farklılıkları değerlendirmek amaçlanmıştır. 1999-2003 yılları arasında Samsun 1. Ağır Ceza Mahkemesi’nde karara bağlanmış dava dosyalarına ait karar kartonları incelenerek, cinsel suçlarla ilgili davalar çalışma kapsamına alınmıştır. Mağdurların %9,4’ü erkek iken, sanıkların tümünün erkek olduğu belirlenmiştir. Sanıkların %43,4’lük oranla en sık 21-30 yaş grubunda, mağdurların ise en sık (%31,6 16-18 yaş grubunda olduğu görülmüştür. Yargıya yansıyan cinsel suçlar arasında en sık ırza geçme suçları olduğu belirlenmiştir. Cinsel suçların adli ve tıbbi boyutu ile ilgilenen tıp ve hukuk mensupları, yeni yasal düzenlemeler yanı sıra cinsel suçların karakteristik özellikleri hakkında da bilgi sahibi olmalıdır. Her ilde ve büyük ilçe merkezlerinde cinsel suçlar değerlendirme merkezleri kurulması gerekmektedir. Anahtar kelimeler: Cinsel suçlar, cinsel saldırı, sanık, mağdur, mahkeme kararı

  15. CT of the pulmonary ligament

    International Nuclear Information System (INIS)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-01-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures

  16. CT of the pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-08-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures.

  17. Finding Neutrinos in LArTPCs using Convolutional Neural Networks

    Science.gov (United States)

    Wongjirad, Taritree

    2017-09-01

    Deep learning algorithms, which have emerged over the last decade, are opening up new ways to analyze data for many particle physics experiments. MicroBooNE, which is a neutrino experiment at Fermilab, has been exploring the use of such algorithms, in particular, convolutional neural networks (CNNS). CNNs are the state-of-the-art method for a large class of problems involving the analysis of images. This makes CNNs an attractive approach for MicroBooNE, whose detector, a liquid argon time projection chamber (LArTPC), produces high-resolution images of particle interactions. In this talk, I will discuss the ways CNNs can be applied to tasks like neutrino interaction detection and particle identification in MicroBooNE and LArTPCs.

  18. Ulnar Collateral Ligament Injuries of the Thumb

    Science.gov (United States)

    McKeon, Kathleen E.; Gelberman, Richard H.; Calfee, Ryan P.

    2013-01-01

    Background: The clinical diagnosis of thumb ulnar collateral ligament disruption has been based on joint angulation during valgus stress testing. This report describes a definitive method of distinguishing between complete and partial ulnar collateral ligament injuries by quantifying translation of the proximal phalanx on the metacarpal head during valgus stress testing. Methods: Sixty-two cadaveric thumbs underwent standardized valgus stress testing under fluoroscopy with the ulnar collateral ligament intact, following an isolated release of the proper ulnar collateral ligament, and following a combined release of both the proper and the accessory ulnar collateral ligament (complete ulnar collateral ligament release). Following complete ulnar collateral ligament release, the final thirty-seven thumbs were also analyzed after the application of a valgus force sufficient to cause 45° of valgus angulation at the metacarpophalangeal joint to model more severe soft-tissue injury. Two independent reviewers measured coronal plane joint angulation (in degrees), ulnar joint line gap formation (in millimeters), and radial translation of the proximal phalanx on the metacarpal head (in millimeters) on digital fluoroscopic images that had been randomized. Results: Coronal angulation across the stressed metacarpophalangeal joint progressively increased through the stages of the testing protocol: ulnar collateral ligament intact (average [and standard deviation], 20° ± 8.1°), release of the proper ulnar collateral ligament (average, 23° ± 8.3°), and complete ulnar collateral ligament release (average, 30° ± 8.9°) (p collateral ligament release (5.7 ± 1.5 mm), to that following complete ulnar collateral ligament release (7.2 ± 1.5 mm) (p collateral ligament (1.6 ± 0.8 mm vs. 1.5 ± 0.9 mm in the intact state). There was a significant increase in translation following release of the complete ulnar collateral ligament complex (3.0 ± 0.9 mm; p collateral ligament

  19. Brinquedo e educação: na escola e no lar

    Directory of Open Access Journals (Sweden)

    Edda Bomtempo

    Full Text Available Como o artigo mostra, brinquedo, brincar e jogar são considerados de grande importância para o desenvolvimento humano. Os tópicos considerados são: aprender brincando ou brincar para aprender; papéis educacionais dos brinquedos e jogos; os professores e os brinquedos; brinquedos e jogos no lar e na escola; o lar como um lugar divertido. Pais e professores precisam estar informados do valor dos brinquedos, brincadeiras e jogos para o desenvolvimento das crianças e dos adolescentes.

  20. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  1. Anatomic ligament consolidation of the superior acromioclavicular ligament and the coracoclavicular ligament complex after acute arthroscopically assisted double coracoclavicular bundle stabilization.

    Science.gov (United States)

    Jobmann, S; Buckup, J; Colcuc, C; Roessler, P P; Zimmermann, E; Schüttler, K F; Hoffmann, R; Welsch, F; Stein, T

    2017-09-18

    The consolidation of the acromioclavicular (AC) and coracoclavicular (CC) ligament complex after arthroscopically assisted stabilization of acute acromioclavicular joint (ACJ) separation is still under consideration. Fifty-five consecutive patients after arthroscopically assisted double-CC-bundle stabilization within 14 days after acute high-grade ACJ separation were studied prospectively. All patients were clinically analysed preoperatively (FU0) and post-operatively (FU1 = 6 months; FU2 = 12 months). The structural MRI assessments were performed at FU0 (injured ACJ) and at FU2 bilateral (radiologic control group) and assessed separately the ligament thickness and length at defined regions for the conoid, trapezoid and the superior AC ligament. Thirty-seven patients were assessed after 6.5 months and after 16.0 months. The 16-month MRI analysis revealed for all patients continuous ligament healing for the CC-complex and the superior AC ligament with in the average hypertrophic consolidation compared to the control side. Separate conoid and trapezoid strands (double-strand configuration) were detected in 27 of 37 (73%) patients, and a single-strand configuration was detected in 10 of 37 (27%) patients; both configurations showed similar CCD data. The ligament healing was not influenced by the point of surgery, age at surgery and heterotopic ossification. The clinical outcome was increased (FU0-FU2): Rowe, 47.7-97.0 pts.; TAFT, 3.9-10.6 pts.; NAS pain , 8.9-1.4 pts. (all P < 0.05). The arthroscopically assisted double-CC-bundle stabilization within 14 days after acute high-grade ACJ separation showed 16 months after surgery sufficient consolidations of the AC and double-CC ligament complex in 73%. III, Case series.

  2. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  3. Kui lokaalne saab olla, et jääda globaalselt huvitavaks? / Lars Nittve ; interv. Anna Mustonen

    Index Scriptorium Estoniae

    Nittve, Lars

    2005-01-01

    Stockholmi moodsa kunsti muuseumi Moderna Museeti direktor Lars Nittve räägib kaasaegse kunstimuuseumi kogumispoliitika väljakutsetest ja rahvuslikkuse aspektist. Lars Nittve eluloolisi andmeid, lühidalt Moderna Museet'ist

  4. Neural Network Optimization of Ligament Stiffnesses for the Enhanced Predictive Ability of a Patient-Specific, Computational Foot/Ankle Model.

    Science.gov (United States)

    Chande, Ruchi D; Wayne, Jennifer S

    2017-09-01

    Computational models of diarthrodial joints serve to inform the biomechanical function of these structures, and as such, must be supplied appropriate inputs for performance that is representative of actual joint function. Inputs for these models are sourced from both imaging modalities as well as literature. The latter is often the source of mechanical properties for soft tissues, like ligament stiffnesses; however, such data are not always available for all the soft tissues nor is it known for patient-specific work. In the current research, a method to improve the ligament stiffness definition for a computational foot/ankle model was sought with the greater goal of improving the predictive ability of the computational model. Specifically, the stiffness values were optimized using artificial neural networks (ANNs); both feedforward and radial basis function networks (RBFNs) were considered. Optimal networks of each type were determined and subsequently used to predict stiffnesses for the foot/ankle model. Ultimately, the predicted stiffnesses were considered reasonable and resulted in enhanced performance of the computational model, suggesting that artificial neural networks can be used to optimize stiffness inputs.

  5. Distonia laríngea respiratória

    Directory of Open Access Journals (Sweden)

    Lebl Mariana Dantas Aumond

    2003-01-01

    Full Text Available A distonia laríngea respiratória (DLR é uma desordem rara caracterizada por espasmos da musculatura adutora das pregas vocais durante a fase inalatória da respiração, com manifestação clínica de dispnéia e estridor. O diagnóstico etiológico do estridor laríngeo, entretanto, nem sempre é fácil de ser realizado, principalmente em situações emergenciais, de forma que a DLR pode não ser diagnosticada, o que nos leva a supor ser mais freqüente do que usualmente é descrita. O diagnóstico da DRL requer primeiramente a realização de uma história médica e exames laringológico e neurológico apropriados, com ênfase na verificação da presença de características distônicas e na exclusão de outras etiologias causadoras de movimentos paradoxais de pregas vocais. Muitos tratamentos foram propostos para a DLR, mas nenhum deles apresentou resultados satisfatórios. O uso da Toxina Botulínica do tipo A (Botox® no músculo tireoaritenoídeo tem oferecido melhoras admiráveis, apesar dos poucos casos descritos. Apresentamos dois casos clínicos de pacientes com DLR tratados com Botox® que apresentavam o fechamento glótico inspiratório causado tanto pelos espasmos anômalos dos músculos tireoaritenoídeos, como pela movimentação paradoxal da epiglote. Dentro da classificação proposta por Koufman e Blabock para as distonias laríngeas, inserimos um novo subtipo de DLR caracterizado pela presença de paroxismos de adução de estruturas glóticas e supraglóticas durante a respiração.

  6. Morphology of the dorsal and lateral calcaneocuboid ligaments.

    Science.gov (United States)

    Dorn-Lange, Nadja V; Nauck, Tanja; Lohrer, Heinz; Arentz, Sabine; Konerding, Moritz A

    2008-09-01

    The dorsolateral calcaneocuboid ligaments have different configurations. In the literature they are only described as either the dorsal or lateral calcaneocuboid ligament. However, recent reconstructive surgical techniques may benefit from a better understanding of the anatomy. The aims of this study were to classify the morphology and attachments of the dorso-lateral calcaneocuboid ligaments and to determine their dimensions. The dorso-lateral aspects of the calcaneocuboid joint of 30 cadaver feet were dissected to expose the associated ligaments. Further, we evaluated possible bony landmarks of the calcaneus that could imply which shape or course the ligament would have in a specific individual. Our findings showed a wide variety of configurations in shape, number, and attachment sites. A constant dorsal ligament and an additional narrower lateral ligament was detectable in half of the cases. The majority of the dorso-lateral calcaneocuboid ligament-complex had an upward course and fanning out from proximal to distal. No bony predictor for the ligaments' shape or course was found. The dorso-lateral ligament-complex of the calcaneocuboid joint revealed a wide variety of configurations. Better understanding of the anatomy of these ligaments may aid in the anatomic reconstruction of these ligaments.

  7. File list: InP.Lar.50.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.50.AllAg.3rd_instar dm3 Input control Larvae 3rd instar SRX287726,SRX331369...87917,SRX287921,SRX288023,SRX467107,SRX016172,SRX016173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.50.AllAg.3rd_instar.bed ...

  8. Lateral collateral ligament (image)

    Science.gov (United States)

    The lateral collateral ligament connects the end of the femur (thigh) to the top of the fibula (the thin bone that runs next to the shin bone). The lateral collateral ligament provides stability against varus stress. Varus stress ...

  9. Sosyal Pekiştireçlerin ve Model Davranışlarının, Çocukların Ahlaki Yargılarının Şekillenmesindeki Etkisi (Bandura Örneği)

    OpenAIRE

    GÜREL, Ramazan

    2014-01-01

    Bu makale, Bandura'nın 5-11 yaş aralığındaki çocukların ahlaki yargılarının şekillenmesinde model alma ve sosyal pekiştireçlerin etkisini test etmek üzere gerçekleştirdiği araştırmasının ulaştığı sonuçları değerlendirmeyi amaçlamaktadır. Bu doğrultuda makalede, Bandura tarafından üç farklı deney ortamında 5-11 yaşlarındaki çocuklar üzerinde, ahlaki gelişim ve uyum sağlamada sosyal öğrenme, pekiştireçler ve model davranışlarının etkilerine dair gerçekleştirilen deneysel faaliyetlerin uygu...

  10. Biomechanical implications of lumbar spinal ligament transection.

    Science.gov (United States)

    Von Forell, Gregory A; Bowden, Anton E

    2014-11-01

    Many lumbar spine surgeries either intentionally or inadvertently damage or transect spinal ligaments. The purpose of this work was to quantify the previously unknown biomechanical consequences of isolated spinal ligament transection on the remaining spinal ligaments (stress transfer), vertebrae (bone remodelling stimulus) and intervertebral discs (disc pressure) of the lumbar spine. A finite element model of the full lumbar spine was developed and validated against experimental data and tested in the primary modes of spinal motion in the intact condition. Once a ligament was removed, stress increased in the remaining spinal ligaments and changes occurred in vertebral strain energy, but disc pressure remained similar. All major biomechanical changes occurred at the same spinal level as the transected ligament, with minor changes at adjacent levels. This work demonstrates that iatrogenic damage to spinal ligaments disturbs the load sharing within the spinal ligament network and may induce significant clinically relevant changes in the spinal motion segment.

  11. Image-anatomic research of the alar ligament

    International Nuclear Information System (INIS)

    Hao Caixian; Liu Jun; Jin Ying; Wang Jian; Zhong Jin; Wang Jinyue; Zhu Miao; Cheng Jinbao

    2008-01-01

    Objective: To detect position and morphous as well as coursing of the alar ligament, and to further investigate the sectional anatomy and CT and MRI imaging of the alar ligament. Methods: Twelve formalin fixed specimens including head and neck utilized, three of the twelve were observed in gross anatomy, nine of them were dissectioned. Fifty- one healthy volunteers from each group were selected to perform CT and MRI examination respectively. By combining gross and sectional anatomy. CT and MRI manifestations of the alar ligament were analyzed, the alar ligament width was measured. Results: Location and shape, as well as coursing of the alar ligament could be demonstrated clearly in gross and sectional anatomy. The transverse plane across the upper dens and the coronal plane by the middle dens were the optimal planes for demonstrating the alar ligament. The display ratio of the alar ligament was even 100% (51/51) in both images of CT and MRI. MRI had better advantages than CT in respect of demonstrating the alar ligament, PDWI (proton density weighted imaging, PDWI) is the most optimal sequence for the alar ligament. There were no significant differences of the alar ligament width between male and female and between the right and the left side (P>0.05). Conclusion: In combination with gross and sectional anatomy. CT and MRI could both provide an imageo-anatomic basis for diagnosis of the alar ligament trauma and malformation as well as infection. (authors)

  12. Memecik Zeytinyağlarının Biyokimyasal Karakterizasyonu

    Directory of Open Access Journals (Sweden)

    Huri İlyasoğlu

    2015-02-01

    Full Text Available Zeytinyağı kalitesi botanik ve coğrafi orijin ile ilişkili olduğundan zeytinyağının çeşit ve bölgesel karakte­rizasyonu önem kazanmıştır. Bu çalışmada, ülkemizin ekonomik açıdan en önemli zeytinyağlarından biri­si olan Memecik zeytinyağlarının kalite parametreleri, yağ asitleri, triaçilgliserol ve sterol kompozisyonu, a-tokoferol ve toplam fenolik madde içerikleri, fenolik madde ve aroma profili belirlenmiştir. Analiz edilen zeytinyağı örneklerinin kalite parametreleri, yağ asitleri ve sterol kompozisyonun (kampesterol hariç, Türk Gıda Kodeksi ile uyumlu olduğu saptanmıştır. Memecik zeytinyağlarında tespit edilen başlıca yağ asitleri oleik asit (% 73.37-75.64, palmitik asit (% 11.45-13.84 ve linoleik asittir (% 7.33-8.91. Triolein (% 63.50-68.32, palmitodiolein (% 18.25-25.82 ve dioleolinolein (% 6.01-9.18 zeytinyağı örneklerinde tespit edilen başlıca triaçilgliserollerdir. Sterol kompozisyonu oluşturan başlıca steroller, b-sitosterol (% 80.76-83.00, D5-avenasterol (% 11.02-12.78 ve kampesteroldür (% 4.01-4.97. Memecik çeşidi zeytinyağlarının fenolik madde profilinde, hidroksitirozol, tirozol, ferulik asit, p-kumarik asit, apigenin ve luteolin ve aroma profi­linde hekzanal, hekzanol, E-2-hekzenal, E-2-hekzenol ve Z-3-hekzenol tespit edilmiştir.

  13. File list: InP.Lar.20.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.20.AllAg.3rd_instar dm3 Input control Larvae 3rd instar SRX467108,SRX287726...67103,SRX288024,SRX288023,SRX104976,SRX016172,SRX467107,SRX016173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.20.AllAg.3rd_instar.bed ...

  14. File list: InP.Lar.10.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.10.AllAg.3rd_instar dm3 Input control Larvae 3rd instar SRX016172,SRX016173...87701,SRX287922,SRX467104,SRX287918,SRX287718,SRX104976,SRX467107 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.10.AllAg.3rd_instar.bed ...

  15. File list: InP.Lar.05.AllAg.3rd_instar [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Lar.05.AllAg.3rd_instar dm3 Input control Larvae 3rd instar SRX016173,SRX288024...87921,SRX287718,SRX331401,SRX287658,SRX331366,SRX287906,SRX287678 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/InP.Lar.05.AllAg.3rd_instar.bed ...

  16. Unilateral aplasia of both cruciate ligaments

    Directory of Open Access Journals (Sweden)

    Liem Dennis

    2010-02-01

    Full Text Available Abstract Aplasia of both cruciate ligaments is a rare congenital disorder. A 28-year-old male presented with pain and the feeling of instability of his right knee after trauma. The provided MRI and previous arthroscopy reports did not indicate any abnormalities except cruciate ligament tears. He was referred to us for reconstruction of both cruciate ligaments. The patient again underwent arthroscopy which revealed a hypoplasia of the medial trochlea and an extremely narrow intercondylar notch. The tibia revealed a missing anterior cruciate ligament (ACL footprint and a single bump with a complete coverage with articular cartilage. There was no room for an ACL graft. A posterior cruciate ligament could not be identified. The procedure was ended since a ligament reconstruction did not appear reasonable. A significant notch plasty if not a partial resection of the condyles would have been necessary to implant a ligament graft. It is most likely that this would not lead to good knee stability. If the surgeon would have retrieved the contralateral hamstrings at the beginning of the planned ligament reconstruction a significant damage would have occurred to the patient. Even in seemingly clear diagnostic findings the arthroscopic surgeon should take this rare abdnormality into consideration and be familiar with the respective radiological findings. We refer the abnormal finding of only one tibial spine to as the "dromedar-sign" as opposed to the two (medial and a lateral tibial spines in a normal knee. This may be used as a hint for aplasia of the cruciate ligaments.

  17. Sacroiliac part of the iliolumbar ligament

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Kleinrensink, G.J.; Snijders, C.; Stoeckart, R.

    1999-01-01

    The iliolumbar ligament has been described as the most important ligament for restraining movement at the lumbosacral junction. In addition, it may play an important role in restraining movement in the sacroiliac joints. To help understand its presumed restraining effect, the anatomy of the ligament

  18. Halkın Genetiği Değiştirilmiş Ürünlere/Üretilme Süreçlerine Yönelik Algıları ve Etik İnançları

    Directory of Open Access Journals (Sweden)

    Özlen Özgen

    2014-02-01

    Full Text Available Bu araştırmanın amacı, halkın genetiği değiştirilmiş ürünlere ve üretilme süreçlerine yönelik fayda/risk algıları ile etik inançları arasındaki ilişkinin incelenmesidir. Araştırma materyalinin toplanmasında karşılıklı görüşme tekniği kullanılmıştır. Likert tipi cümlelere verilen yanıtlar puanlanmış, geçerlik ve güvenirlik analizi yapılmıştır. Yaş değişkenine bağlı farklılığın belirlenebilmesi için t-testi uygulanmıştır. Bireylerin genetiği değiştirilmiş ürünlere/üretilme süreçlerine bağlı fayda/risk algıları ile etik inançları arasındaki ilişkinin incelenmesi amacı ile Pearson korelasyon analizi yapılmıştır. Bulgular; tüketicilerin genetiği değiştirilmiş ürünlere ilişkin fayda algılarının, genetiği değiştirilmiş ürünlere ve üretilme süreçlerine ilişkin risk algılarının, genetiği değiştirilmiş ürünlere ve üretilme süreçlerine ilişkin etik inançlarının yaşa bağlı olarak değiştiğini göstermektedir. Pearson korelasyon analizi sonucunda p<0.001 düzeyinde anlamlı ilişkiler saptanmıştır.

  19. Developing Light Collection Enhancements and Wire Tensioning Methods for LArTPC Neutrino Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Spagliardi, Fabio [Univ. of Manchester (United Kingdom)

    2017-01-01

    Liquid argon Time Projection Chambers (LArTPCs) are becoming widely used as neutrino detectors because of their image-like event reconstruction which enables precision neutrino measurements. They primarily use ionisation charge to reconstruct neutrino events. It has been shown, however, that the scintillation light emitted by liquid argon could be exploited to improve their performance. As the neutrino measurements planned in the near future require large-scale experiments, their construction presents challenges in terms of both charge and light collection. In this dissertation we present solutions developed to improve the performance in both aspects of these detectors. We present a new wire tensioning measurement method that allows a remote measurement of the tension of the large number wires that constitute the TPC anode. We also discuss the development and installation of WLS-compound covered foils for the SBND neutrino detector at Fermilab, which is a technique proposed t o augment light collection in LArTPCs. This included preparing a SBND-like mesh cathode and testing it in the Run III of LArIAT, a test beam detector also located at Fermilab. Finally, we present a study aimed at understanding late scintillation light emitted by recombining positive argon ions using LArIAT data, which could affect large scale surface detectors.

  20. Neck ligament strength is decreased following whiplash trauma

    Directory of Open Access Journals (Sweden)

    Rubin Wolfgang

    2006-12-01

    Full Text Available Abstract Background Previous clinical studies have documented successful neck pain relief in whiplash patients using nerve block and radiofrequency ablation of facet joint afferents, including capsular ligament nerves. No previous study has documented injuries to the neck ligaments as determined by altered dynamic mechanical properties due to whiplash. The goal of the present study was to determine the dynamic mechanical properties of whiplash-exposed human cervical spine ligaments. Additionally, the present data were compared to previously reported control data. The ligaments included the anterior and posterior longitudinal, capsular, and interspinous and supraspinous ligaments, middle-third disc, and ligamentum flavum. Methods A total of 98 bone-ligament-bone specimens (C2–C3 to C7-T1 were prepared from six cervical spines following 3.5, 5, 6.5, and 8 g rear impacts and pre- and post-impact flexibility testing. The specimens were elongated to failure at a peak rate of 725 (SD 95 mm/s. Failure force, elongation, and energy absorbed, as well as stiffness were determined. The mechanical properties were statistically compared among ligaments, and to the control data (significance level: P Results For all whiplash-exposed ligaments, the average failure elongation exceeded the average physiological elongation. The highest average failure force of 204.6 N was observed in the ligamentum flavum, significantly greater than in middle-third disc and interspinous and supraspinous ligaments. The highest average failure elongation of 4.9 mm was observed in the interspinous and supraspinous ligaments, significantly greater than in the anterior longitudinal ligament, middle-third disc, and ligamentum flavum. The average energy absorbed ranged from 0.04 J by the middle-third disc to 0.44 J by the capsular ligament. The ligamentum flavum was the stiffest ligament, while the interspinous and supraspinous ligaments were most flexible. The whiplash

  1. Dead Time in the LAr Calorimeter Front-End Readout

    CERN Document Server

    Gingrich, D M

    2002-01-01

    We present readout time, latency, buffering, and dead-time calculations for the switched capacitor array controllers of the LAr calorimeter. The dead time is compared with algorithms for the dead-time generation in the level-1 central trigger processor.

  2. MR imaging of posttraumatic spinal ligament injury

    International Nuclear Information System (INIS)

    Pathria, M.N.; Emery, S.; Masaryk, T.J.; Wilber, R.G.; Bohlman, H.

    1988-01-01

    The accuracy of MR imaging in the detection of ligamentous injury was evaluated in 29 patients (24 male, five female) with spinal injury resulting in fractures (n=27), evidence of instability (n=11), or neurologic deficit (n=2). MR examinations were performed acutely (average, 7.5 days posttrauma) with T1- and T2-weighted imaging and were blindly evaluated. Subsequently, plain films (n=27), tomograms (n=10), and CT scans (n=22) were evaluated. Eighteen patients underwent surgery. Fourteen patients had torn ligaments as indicated by clinical and surgical findings. MR imaging demonstrated ligament damage in 13. One case imaged 40 days following trauma was not detected. No patients with intact ligaments had evidence of ligamentous damage on MR images. MR imaging demonstrated retropulsed fractures in six patients in whom the posterior longitudinal ligament was intact but displaced from the vertebra. MR imaging was more reliable than radiography and CT for detection of ligamentous injury, and T2- weighted sequences are essential in such cases

  3. Genetic association analysis of LARS2 with type 2 diabetes

    DEFF Research Database (Denmark)

    Reiling, E; Jafar-Mohammadi, B; van 't Riet, E

    2010-01-01

    was to establish the true contribution of this variant and common variants in LARS2 (MAF > 5%) to type 2 diabetes risk. METHODS: We combined genome-wide association data (n = 10,128) from the DIAGRAM consortium with independent data derived from a tagging single nucleotide polymorphism (SNP) approach in Dutch...... individuals (n = 999) and took forward two SNPs of interest to replication in up to 11,163 Dutch participants (rs17637703 and rs952621). In addition, because inspection of genome-wide association study data identified a cluster of low-frequency variants with evidence of type 2 diabetes association, we...... of sequence variants in LARS2 in type 2 diabetes susceptibility, we found no evidence to support previous data indicating a role in type 2 diabetes susceptibility....

  4. MR imaging of alar and transverse atlantal ligament injuries

    Energy Technology Data Exchange (ETDEWEB)

    Echigoya, Naoki; Harata, Seiko; Ueyama, Kazumasa (Hirosaki Univ., Aomori (Japan). School of Medicine); Nakano, Keisuke

    1992-06-01

    Autopsy findings of ligaments of the upper cervical spine were compared with magnetic resonance imaging (MRI) findings. Ligaments were clearly shown as hypointensity on T1-weighted images and proton density images. Transverse images were useful in diagnosing alar and transverse atlantal ligament injuries. When there is a bilateral difference in the alar ligaments, ruptured ligament is suspected. Transverse ligament rupture was shown on interrupted hypointensity and as hyperintensity. MRI was capable of diagnosing alar ligament rupture in 8 of 11 patients, and transverse ligament rupture in all 3 patients. In 2 patients having Jefferson's fracture and injuried atlanoaxial subluxation encountered in the clinical practice, transverse ligament rupture was similarly observed as that in autopsy cases on MR images. Hyperintensity in the transverse ligament rupture area was seen even one year after injury. Injured transverse ligament was seen as swollen hyperintensity on sagittal images; and the hyperintensity was gradually decreased with the process of healing. (N.K.).

  5. Deltoid ligament in acute ankle injury: MR imaging analysis

    International Nuclear Information System (INIS)

    Jeong, Min Sun; Choi, Yun Sun; Kim, Yun Jung; Jung, Yoon Young; Kim, Jin Su; Young, Ki Won

    2014-01-01

    To identify the pattern of deltoid ligament injury after acute ankle injury and the relationship between ankle fracture and deltoid ligament tear by magnetic resonance imaging (MRI). Thirty-six patients (32 male, and 4 female; mean age, 29.8 years) with acute deltoid ligament injury who had undergone MRI participated in this study. The deltoid ligament was classified as having 3 superficial and 2 deep components. An image analysis included the integrity and tear site of the deltoid ligament, and other associated injuries. Association between ankle fracture and deltoid ligament tear was assessed using Fisher's exact test (P < 0.05). Of the 36 patients, 21 (58.3 %) had tears in the superficial and deep deltoid ligaments, 6 (16.7 %) in the superficial ligaments only, and 4 (11.1 %) in the deep ligaments only. The most common tear site of the three components of the superficial deltoid and deep anterior tibiotalar ligaments was their proximal attachments (94 % and 91.7 % respectively), and that of the deep posterior tibiotalar ligament (pTTL) was its distal attachment (82.6 %). The common associated injuries were ankle fracture (63.9 %), syndesmosis tear (55.6 %), and lateral collateral ligament complex tear (44.4 %). All the components of the deltoid ligament were frequently torn in patients with ankle fractures (tibionavicular ligament, P = 0.009). The observed injury pattern of the deltoid ligament was complex and frequently associated with concomitant ankle pathology. The most common tear site of the superficial deltoid ligament was the medial malleolar attachment, whereas that of the deep pTTL was near its medial talar insertion. (orig.)

  6. Functional tissue engineering of ligament healing

    Directory of Open Access Journals (Sweden)

    Hsu Shan-Ling

    2010-05-01

    Full Text Available Abstract Ligaments and tendons are dense connective tissues that are important in transmitting forces and facilitate joint articulation in the musculoskeletal system. Their injury frequency is high especially for those that are functional important, like the anterior cruciate ligament (ACL and medial collateral ligament (MCL of the knee as well as the glenohumeral ligaments and the rotator cuff tendons of the shoulder. Because the healing responses are different in these ligaments and tendons after injury, the consequences and treatments are tissue- and site-specific. In this review, we will elaborate on the injuries of the knee ligaments as well as using functional tissue engineering (FTE approaches to improve their healing. Specifically, the ACL of knee has limited capability to heal, and results of non-surgical management of its midsubstance rupture have been poor. Consequently, surgical reconstruction of the ACL is regularly performed to gain knee stability. However, the long-term results are not satisfactory besides the numerous complications accompanied with the surgeries. With the rapid development of FTE, there is a renewed interest in revisiting ACL healing. Approaches such as using growth factors, stem cells and scaffolds have been widely investigated. In this article, the biology of normal and healing ligaments is first reviewed, followed by a discussion on the issues related to the treatment of ACL injuries. Afterwards, current promising FTE methods are presented for the treatment of ligament injuries, including the use of growth factors, gene delivery, and cell therapy with a particular emphasis on the use of ECM bioscaffolds. The challenging areas are listed in the future direction that suggests where collection of energy could be placed in order to restore the injured ligaments and tendons structurally and functionally.

  7. Deltoid ligament in acute ankle injury: MR imaging analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Min Sun; Choi, Yun Sun; Kim, Yun Jung; Jung, Yoon Young [Eulji University, Department of Radiology, Eulji Hospital, Seoul (Korea, Republic of); Kim, Jin Su; Young, Ki Won [Eulji University, Department of Orthopedic Surgery, Eulji Hospital, Seoul (Korea, Republic of)

    2014-05-15

    To identify the pattern of deltoid ligament injury after acute ankle injury and the relationship between ankle fracture and deltoid ligament tear by magnetic resonance imaging (MRI). Thirty-six patients (32 male, and 4 female; mean age, 29.8 years) with acute deltoid ligament injury who had undergone MRI participated in this study. The deltoid ligament was classified as having 3 superficial and 2 deep components. An image analysis included the integrity and tear site of the deltoid ligament, and other associated injuries. Association between ankle fracture and deltoid ligament tear was assessed using Fisher's exact test (P < 0.05). Of the 36 patients, 21 (58.3 %) had tears in the superficial and deep deltoid ligaments, 6 (16.7 %) in the superficial ligaments only, and 4 (11.1 %) in the deep ligaments only. The most common tear site of the three components of the superficial deltoid and deep anterior tibiotalar ligaments was their proximal attachments (94 % and 91.7 % respectively), and that of the deep posterior tibiotalar ligament (pTTL) was its distal attachment (82.6 %). The common associated injuries were ankle fracture (63.9 %), syndesmosis tear (55.6 %), and lateral collateral ligament complex tear (44.4 %). All the components of the deltoid ligament were frequently torn in patients with ankle fractures (tibionavicular ligament, P = 0.009). The observed injury pattern of the deltoid ligament was complex and frequently associated with concomitant ankle pathology. The most common tear site of the superficial deltoid ligament was the medial malleolar attachment, whereas that of the deep pTTL was near its medial talar insertion. (orig.)

  8. Arrival of the last cryostat for the ATLAS LAr calorimeter at CERN

    CERN Multimedia

    Aleksa, M; Oberlack, H

    On Wednesday, 4th June the last cryostat for the ATLAS LAr calorimeter (end-cap A) arrived at CERN and was immediately unloaded from the truck in building 180 (see Figures 1 and 2), where the integration of the LAr calorimeters into their cryostats takes place. The transport from the Italian company SIMIC, where both end-cap calorimeters have been produced took longer than expected due to delays because of the G8 summit. Thanks to the great effort by the CERN Host State office and the French-German steering group that supplies the end-cap cryostat as an in-kind contribution to the LAr collaboration, an exceptional convoy was finally available and the cryostat could make its way to CERN. Fig.1 (left): Truck with the end-cap cryostat. Fig.2 (right): Unloading the cryostat in bldg. 180. Each end-cap cryostat will contain an electromagnetic calorimeter wheel, two wheels of a hadronic calorimeter, and a forward calorimeter. The design of the cryostat as a double vessel structure made of Aluminum fulfills t...

  9. Radio sterilized human ligaments and their clinical application

    International Nuclear Information System (INIS)

    Luna Z, D.; Reyes F, M. L.; Diaz M, I.; Hernandez R, G.

    2009-10-01

    The ligaments are human tissues that are used in the transplantation area. A ligament is an anatomical structure in band form, composed by resistant fibers that connect the tissues that unite the bones with the articulations. In an articulation, the ligaments allow and facilitate the movement inside the natural anatomical directions, while it restricts those movements that are anatomically abnormal, impeding lesions that could arise of this type of movements. The kneecap ligament is a very important tissue in the knee mobility and of walking in the human beings. This ligament can injure it because of automobile accidents, for sport lesions or illnesses, and in many cases the only form of recovering the knee movement is carried out a transplant with the purpose of replacing the damage ligament by allo gen kneecap ligament processed in specialized Tissue Banks where the tissue is sterilized with gamma radiation of 60 Co at very low temperatures, obtaining high quality ligaments for clinical application in injured patients. The kneecap ligaments are processed in the Tissue Banks with a segment of kneecap bone, a segment of tibial bone, the contained ligament between both bones and in some cases a fraction of the quadriceps tendon. In this work is given a description of the selection method of the tissue that includes the donor's serologic control, the kneecap ligament processing in the Radio Sterilized Tissues Bank, its sterilization with gamma radiation of 60 Co, also it is indicated like the clinical application of the allo gen ligament was realized in a hasty patient and whose previous crossed ligament was injured. Finally the results are presented from the tissue obtaining until the clinical application of it is, and in this case is observed a favorable initial evolution of the transplantation patient. (Author)

  10. Chronic injuries of the cruciate ligaments

    International Nuclear Information System (INIS)

    Pricca, P.; Cecchini, A.; Vecchioni, G.; Mariani, P.M.; Tansini, A.; Ferrario, A.

    1988-01-01

    The high incidence of cruciate ligament injuries as a result of acute knee trauma with hemartrosis and abuse of diagnostic arthroscopies call for a suitable radiological imaging of the central pivot. Computed Arthrotomography (CAT) was used to examine the knee joint in 20 cases of clinically suspected chronic cruciate ligament injury. The images were correlated with arthroscopic and/or arthrotomic findings. Thirteen lesions of the anterior cruciate ligament (ACL) (65%) were found, plus 1 lesion of the posterior cruciate ligament (PCL) (5%), 2 associated lesions of ACL + PCL (10%), and 4 normal cases. Confirmation of pathology was available in all cases but one by arthroscopy and/or surgery. The central pivot diseases were classified as follows: absence, detachement, partial or complete tear. CAT findings of cruciate ligament injuries are emphasized and the role of the technique as compared to arthroscopy is discussed. CAT is useful in 3-D evaluation of central pivot and detection of different cruciate ligament injuries, with high sensitivity-specifity for ACL and high specifity-moderate sensitivity for PCL. In the evaluation of the chronic unstable knee, CAT is highly accurate and gives the surgeon useful information towards the planning of therapeutic procedures. CAT is almost non-invasive, well tolerated and easy to perform in out-patients, which make it a first-choice procedure in the screening of chronic ligament injuries

  11. ATLAS LAr Calorimeter Performance in LHC Run-2

    CERN Document Server

    Morgenstern, Stefanie; The ATLAS collaboration

    2018-01-01

    Liquid-argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region $\\eta<3.2$, and for hadronic and forward calorimetry in the region from $\\eta=1.5$ to $\\eta=4.9$. In the first LHC run a total luminosity of $27\\,\\mathrm{fb}^{-1}$ has been collected at centre-of-mass energies of $7-8\\,\\mathrm{TeV}$. After detector consolidation during a long shutdown, Run-2 started in 2015 and $86.4\\,\\mathrm{fb}^{-1}$ of data at a centre-of-mass energy of $13\\,\\mathrm{TeV}$ have been recorded. In order to realize the level-1 acceptance rate of $100\\,\\mathrm{kHz}$ in Run-2 data taking, the number of readout samples recorded and used for the energy and the time measurement has been modified from five to four while keeping the expected performance. The well calibrated and highly granular LAr calorimeter reached its design values both in energy measurement as well as in direction resolution. This contribution will give an overview of the detector operation, hardware...

  12. Anatomy of the ankle ligaments: a pictorial essay

    NARCIS (Netherlands)

    Golanó, Pau; Vega, Jordi; de Leeuw, Peter A. J.; Malagelada, Francesc; Manzanares, M. Cristina; Götzens, Víctor; van Dijk, C. Niek

    2010-01-01

    Understanding the anatomy of the ankle ligaments is important for correct diagnosis and treatment. Ankle ligament injury is the most frequent cause of acute ankle pain. Chronic ankle pain often finds its cause in laxity of one of the ankle ligaments. In this pictorial essay, the ligaments around the

  13. Anatomy of the ankle ligaments: a pictorial essay

    NARCIS (Netherlands)

    Golanó, Pau; Vega, Jordi; de Leeuw, Peter A. J.; Malagelada, Francesc; Manzanares, M. Cristina; Götzens, Víctor; van Dijk, C. Niek

    2016-01-01

    Understanding the anatomy of the ankle ligaments is important for correct diagnosis and treatment. Ankle ligament injury is the most frequent cause of acute ankle pain. Chronic ankle pain often finds its cause in laxity of one of the ankle ligaments. In this pictorial essay, the ligaments around the

  14. Mobil reklamlar ve mobil reklam araçlarına yönelik tutumlar

    OpenAIRE

    Barutçu, Süleyman; Öztürk Göl, Meltem

    2009-01-01

    Bu çalışmanın amacı, pazarlama bölümü yöneticilerinin dikkatlerini mobil iletişim teknolojilerindeki gelişmelerin sonucu olarak ortaya çıkan mobil pazarlama ve mobil reklam uygulamalarına çekmektir. Çalışmanın kavramsal analiz bölümünde mobil pazarlama, mobil reklamların önemi açıklanmış ve mobil reklam araçları (SMS, MMS ve Bluetooth Reklamları) analiz edilmiştir. Araştırma bölümünde ise mobil telefon kullanıcılarının mobil reklam araçlarına yönelik tutumlarının karşılaştırmalı olarak belirl...

  15. Artificial organs versus regenerative medicine: is it true?

    Science.gov (United States)

    Nosé, Yukihiko; Okubo, Hisashi

    2003-09-01

    Individuals engaged in the fields of artificial kidney and artificial heart have often mistakenly stated that "the era of artificial organs is over; regenerative medicine is the future." Contrarily, we do not believe artificial organs and regenerative medicine are different medical technologies. As a matter of fact, artificial organs developed during the last 50 years have been used as a bridge to regeneration. The only difference between regenerative medicine and artificial organs is that artificial organs for the bridge to regeneration promote tissue regeneration in situ, instead of outside the body (for example, vascular prostheses, neuroprostheses, bladder substitutes, skin prostheses, bone prostheses, cartilage prostheses, ligament prostheses, etc.). All of these artificial organs are successful because tissue regeneration over a man-made prosthesis is established inside the patient's body (artificial organs to support regeneration). Another usage of the group of artificial organs for the bridge to regeneration is to sustain the functions of the patient's diseased organs during the regeneration process of the body's healthy tissues and/or organs. This particular group includes artificial kidney, hepatic assist, respiratory assist, and circulatory assist. Proof of regeneration of these healthy tissues and/or organs is demonstrated in the short-term recovery of end-stage organ failure patients (artificial organs for bridge to regeneration). A third group of artificial organs for the bridge to regeneration accelerates the regenerating process of the patient's healthy tissues and organs. This group includes neurostimulators, artificial blood (red cells) blood oxygenators, and plasmapheresis devices, including hemodiafiltrators. So-called "therapeutic artificial organs" fall into this category (artificial organs to accelerate regeneration). Thus, almost all of today's artificial organs are useful in the bridge to regeneration of healthy natural tissues and organs

  16. Trends in Materials Science for Ligament Reconstruction.

    Science.gov (United States)

    Sava, Oana Roxana; Sava, Daniel Florin; Radulescu, Marius; Albu, Madalina Georgiana; Ficai, Denisa; Veloz-Castillo, Maria Fernanda; Mendez-Rojas, Miguel Angel; Ficai, Anton

    2017-01-01

    The number of ligament injuries increases every year and concomitantly the need for materials or systems that can reconstruct the ligament. Limitations imposed by autografts and allografts in ligament reconstruction together with the advances in materials science and biology have attracted a lot of interest for developing systems and materials for ligament replacement or reconstruction. This review intends to synthesize the major steps taken in the development of polymer-based materials for anterior cruciate ligament, their advantages and drawbacks and the results of different in vitro and in vivo tests. Until present, there is no successful polymer system for ligament reconstruction implanted in humans. The developing field of synthetic polymers for ligament reconstruction still has a lot of potential. In addition, several nano-structured materials, made of nanofibers or in the form of ceramic/polymeric nanocomposites, are attracting the interest of several groups due to their potential use as engineered scaffolds that mimic the native environment of cells, increasing the chances for tissue regeneration. Here, we review the last 15 years of literature in order to obtain a better understanding on the state-of-the-art that includes the usage of nano- and poly-meric materials for ligament reconstruction, and to draw perspectives on the future development of the field. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    Science.gov (United States)

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Ligament Tissue Engineering and Its Potential Role in Anterior Cruciate Ligament Reconstruction

    OpenAIRE

    Yates, E. W.; Rupani, A.; Foley, G. T.; Khan, W. S.; Cartmell, S.; Anand, S. J.

    2011-01-01

    Tissue engineering is an emerging discipline that combines the principle of science and engineering. It offers an unlimited source of natural tissue substitutes and by using appropriate cells, biomimetic scaffolds, and advanced bioreactors, it is possible that tissue engineering could be implemented in the repair and regeneration of tissue such as bone, cartilage, tendon, and ligament. Whilst repair and regeneration of ligament tissue has been demonstrated in animal studies, further research ...

  19. On the behavior of crack surface ligaments

    International Nuclear Information System (INIS)

    Nilsson, P.; Staahle, P.; Sundin, K.G.

    1998-01-01

    Small ligaments connecting the fracture surfaces just behind a moving crack front are assumed to exist under certain conditions. The ligaments are rapidly torn as the crack advances. Inelastic straining of such ligaments influences the energy balance in the fracture process. The rapid tearing of a single ligament is studied both numerically and experimentally. An elastic visco-plastic material model is adopted for finite-element calculations. The results show that relatively large amounts of energy are dissipated during the tearing process. Further, the energy needed to tear a ligament increases rapidly with increasing tearing rate. The computed behavior is partly verified in a few preliminary experiments. The implications for slow stable crack tip speeds during dynamic fracture are discussed. (orig.)

  20. Budget impact of pasireotide LAR for the treatment of acromegaly, a rare endocrine disorder.

    Science.gov (United States)

    Zhang, J J; Nellesen, D; Ludlam, W H; Neary, M P

    2016-01-01

    Acromegaly is a rare disorder characterized by the over-production of growth hormone (GH). Patients often experience a range of chronic comorbidities including hypertension, cardiac dysfunction, diabetes, osteoarthropathy, and obstructive sleep apnea. Untreated or inadequately controlled patients incur substantial healthcare costs, while normalization of GH levels may reduce morbidity and mortality rates to be comparable to the general population. To assess the 3-year budget impact of pasireotide LAR on a US managed care health plan following pasireotide LAR availability. Two separate economic models were developed: one from the perspective of an entire health plan and another from the perspective of a pharmacy budget. The total budget impact model includes costs of drug therapies and other costs for treatment, monitoring, management of adverse events, and comorbidities. The pharmacy cost calculator only considers drug costs. The total estimated budget impact associated with the introduction of pasireotide LAR is 0.31 cents ($0.0031) per member per month (PMPM) in the first year, 0.78 cents ($0.0078) in the second year, and 1.42 cents ($0.0142) in the third year following FDA approval. Costs were similar or lower from a pharmacy budget impact perspective. For each patient achieving disease control, cost savings from reduced comorbidities amounted to $10,240 per year. Published data on comorbidities for acromegaly are limited. In the absence of data on acromegaly-related costs for some comorbidities, comorbidity costs for the general population were used (may be under-estimates). The budget impact of pasireotide LAR is expected to be modest, with an expected increase of 1.42 cents PMPM on the total health plan budget in the third year after FDA approval. The efficacy of pasireotide LAR in acromegaly, as demonstrated in head-to-head trials compared with currently available treatment options, is expected to be associated with a reduction of the prevalence of

  1. MRI of injuries of the lateral ankle ligaments

    International Nuclear Information System (INIS)

    Breitenseher, Martin

    2011-01-01

    The most frequent sport injury of the ankle is located in the lateral ankle ligaments. The diagnosis of lateral collateral ankle ligament trauma is based on patient history, clinical examination, and stress radiography, allowing a fair diagnosis for the daily routine. For the direct visualization and precise diagnosis of the lateral ankle ligaments MRI provides the best answer. MRI is used with controlled positioning of the foot, correct angulation of sequenzes, and distinct analysis of MR findings. Sinus tarsi ligaments and ligaments of the distal syndesmosis should be included to the report. In selected patients MRI allows the best evaluation of the extent of the lateral ankle ligaments. MRI is the method of choice for combined osteochondral injuries and soft tissue lesions too. (orig.)

  2. The spinoglenoid ligament. Anatomy, morphology, and histological findings.

    Science.gov (United States)

    Plancher, Kevin D; Peterson, Robert K; Johnston, Jack C; Luke, Timothy A

    2005-02-01

    Dysfunction of the distal branch of the suprascapular nerve has been reported in athletes involved in throwing or overhead sports. The consistent presence of a dynamic anatomic structure, the spinoglenoid ligament, overlying the nerve in the spinoglenoid notch may be a contributing factor to the dysfunction of this nerve. The purpose of this study was to report the anatomy, morphology, and histological characteristics of the spinoglenoid ligament. The spinoglenoid ligaments of fifty-eight fresh-frozen cadaver shoulders were dissected to evaluate their anatomic dimensions, histological characteristics, and relationship to the suprascapular nerve, the posterior part of the capsule, and the glenoid rim. The spinoglenoid ligament was harvested, with its insertions on the scapular spine and on the capsule and glenoid left intact, for the histological analysis. Dissection revealed that a spinoglenoid ligament was present in all specimens. The ligament was found to form an irregular quadrangular shape. On gross examination, the deep fibers of the ligament extended from the lateral aspect of the scapular spine to the posterior part of the glenoid and the superficial fibers blended with the posterior aspect of the shoulder capsule. Histological sections demonstrated Sharpey fibers inserting into bone at the scapular spine and blending with the posterior aspect of the shoulder capsule to insert into the posterior surface of the glenoid, findings that confirmed the ligamentous nature of this structure. This study revealed the presence of the spinoglenoid ligament in all of the shoulders that were examined, with some variation in the size of the ligament.

  3. ATLAS LAr Calorimeter Performance in LHC Run-2

    CERN Document Server

    Morgenstern, Stefanie; The ATLAS collaboration

    2018-01-01

    Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region eta<3.2, and for hadronic and forward calorimetry in the region from eta=1.5 to eta=4.9. In the first LHC run a total luminosity of 27 fb-1 has been collected at c.o.m energies of 7-8 TeV. After detector consolidation during a long shutdown, Run-2 started in 2015 and 86.4fb-1 of data at a c.o.m energy of 13 TeV have been recorded. In order to realize the level-1 acceptance rate of 100 kHz in Run-2 data taking, the number of read-out samples recorded and used for the energy and the time measurement has been modified from five to four while keeping the expected performance. The well calibrated and highly granular LAr Calorimeter reached its design values both in energy measurement as well as in direction resolution. This contribution will give an overview of the detector operation, hardware improvements, changes in the monitoring and data quality procedures, to cope with increased ...

  4. Tissue Engineering Strategies in Ligament Regeneration

    OpenAIRE

    Yilgor, Caglar; Yilgor Huri, Pinar; Huri, Gazi

    2011-01-01

    Ligaments are dense fibrous connective tissues that connect bones to other bones and their injuries are frequently encountered in the clinic. The current clinical approaches in ligament repair and regeneration are limited to autografts, as the gold standard, and allografts. Both of these techniques have their own drawbacks that limit the success in clinical setting; therefore, new strategies are being developed in order to be able to solve the current problems of ligament grafting. Tissue eng...

  5. The Cruciate Ligaments in Total Knee Arthroplasty.

    Science.gov (United States)

    Parcells, Bertrand W; Tria, Alfred J

    2016-01-01

    The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction.

  6. Instrument-assisted cross-fiber massage accelerates knee ligament healing.

    Science.gov (United States)

    Loghmani, M Terry; Warden, Stuart J

    2009-07-01

    Controlled laboratory study. To investigate the effects of instrument-assisted cross-fiber massage (IACFM) on tissue-level healing of knee medial collateral ligament (MCL) injuries. Ligament injuries are common and significant clinical problems for which there are few established interventions. IACFM represents an intervention that may mediate tissue-level healing following ligament injury. Bilateral knee MCL injuries were created in 51 rodents, while 7 rodents were maintained as ligament-intact, control animals. IACFM was commenced 1 week following injury and introduced 3 sessions per week for 1 minute per session. IACFM was introduced unilaterally (IACFM-treated), with the contralateral, injured MCL serving as an internal control (nontreated). Thirty-one injured animals received 9 ACFM treatments, while the remaining 20 injured animals received 30 treatments. Ligament biomechanical properties and morphology were assessed at either 4 or 12 weeks postinjury. IACFM-treated ligaments were 43.1% stronger (P<.05), 39.7% stiffer (P<.01), and could absorb 57.1% more energy before failure (P<.05) than contralateral, injured, nontreated ligaments at 4 weeks postinjury. On histological and scanning electron microscopy assessment, IACFM-treated ligaments appeared to have improved collagen fiber bundle formation and orientation within the scar region than nontreated ligaments. There were minimal differences between IACFM-treated and contralateral, nontreated ligaments at 12 weeks postinjury, although IACFM-treated ligaments were 15.4% stiffer (P<.05). IACFM-accelerated ligament healing, possibly via favorable effects on collagen formation and organization, but had minimal effect on the final outcome of healing. These findings are clinically interesting, as there are few established interventions for ligament injuries, and IACFM is a simple and practical therapy technique. J Orthop Sports Phys Ther 2009;39(7):506-514, Epub 24 February 2009. doi:10.2519/jospt.2009.2997.

  7. Posterior longitudinal ligament status in cervical spine bilateral facet dislocations

    International Nuclear Information System (INIS)

    Carrino, John A.; Manton, Geoffrey L.; Morrison, William B.; Flanders, Adam E.; Vaccaro, Alex R.; Schweitzer, Mark E.

    2006-01-01

    It is generally accepted that cervical spine bilateral facet dislocation results in complete disruption of the posterior longitudinal ligament. The goal of this study was to evaluate the integrity of numerous spine-stabilizing structures by MRI, and to determine if any associations between injury patterns exist with respect to the posterior longitudinal ligament status. Retrospective case series. A retrospective review was performed of 30 cervical spine injury subjects with bilateral facet dislocation. Assessment of 1.5T MRI images was carried out for: intervertebral disc disruption, facet fracture, and ligamentous disruption. Statistical analyses were performed to evaluate for associations between various injury patterns and posterior longitudinal ligament status. The frequency of MRI abnormalities was: anterior longitudinal ligament disruption (26.7%), disc herniation or disruption (90%), posterior longitudinal ligament disruption (40%), facet fracture (63.3%) and disruption of the posterior column ligament complex (97%). There were no significant associations between injury to the posterior longitudinal ligament and other structures. Compared to surgical reports, MRI was accurate for determining the status for 24 of 26 ligaments (three of three anterior longitudinal ligament, seven of nine posterior longitudinal ligament, and 14 of 14 posterior column ligament complex) but generated false negatives in two instances (in both MRI showed an intact posterior longitudinal ligament that was torn at surgery). (orig.)

  8. Whiplash causes increased laxity of cervical capsular ligament

    Science.gov (United States)

    Ivancic, Paul C.; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P.; Ndu, Anthony B.; Carlson, Erik J.; Panjabi, Manohar M.

    2009-01-01

    Background Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. Methods A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1 mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Findings Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Interpretation Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients. PMID:17959284

  9. Whiplash causes increased laxity of cervical capsular ligament.

    Science.gov (United States)

    Ivancic, Paul C; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P; Ndu, Anthony B; Carlson, Erik J; Panjabi, Manohar M

    2008-02-01

    Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients.

  10. Recruitment of knee joint ligaments

    NARCIS (Netherlands)

    Blankevoort, L.; Huiskes, H.W.J.; Lange, de A.

    1991-01-01

    On the basis of earlier reported data on the in vitro kinematics of passive knee-joint motions of four knee specimens, the length changes of ligament fiber bundles were determined by using the points of insertion on the tibia and femur. The kinematic data and the insertions of the ligaments were

  11. Ultrasonographic evaluation of normal extrinsic and intrinsic carpal ligaments: preliminary experience

    International Nuclear Information System (INIS)

    Boutry, Nathalie; Lapegue, Franck; Demondion, Xavier; Masi, Laetitia; Cotten, Anne; Claret, Antoine

    2005-01-01

    To determine normal anatomy of extrinsic and intrinsic carpal ligaments at ultrasonography (US). In the first part of the study, two musculoskeletal radiologists retrospectively reviewed in consensus the photographs of anatomic sections and dissections derived from 20 cadaveric wrists. This cadaveric study gave the two readers the opportunity to learn the anatomy and orientation of the various extrinsic and intrinsic carpal ligaments and, thus, to develop a US protocol to facilitate the recognition of each carpal ligament. In the second part of the study, these two radiologists prospectively and independently evaluated the visibility of extrinsic and intrinsic carpal ligaments in 30 wrists of volunteers, using the same US protocol. With regard to extrinsic carpal ligaments, the radioscaphocapitate ligament (partially visible, 38%; completely visible, 62%), the radiolunotriquetral ligament (partially visible, 27%; completely visible, 73%), the palmar ulnotriquetral ligament (partially visible, 12%; completely visible, 88%), and the dorsal radiotriquetral ligament (partially visible, 7%; completely visible, 93%) were visualized at US. The dorsal ulnotriquetral ligament (partially visible, 21%; completely visible, 74%), the ulnolunate ligament (partially visible, 5%; completely visible, 70%), and the radial collateral ligament (partially visible, 18%; completely visible, 12%) were more difficult to recognize. The radioscapholunate ligament was never seen. With regard to intrinsic carpal ligaments, the dorsal (partially visible, 11%; completely visible, 89%) and palmar (partially visible, 38%; completely visible, 62%) scaphotriquetral ligaments as well as the dorsal scapholunate ligament (partially visible, 3%; completely visible, 97%) were visualized at US. The dorsal lunotriquetral ligament (partially visible, 39%; completely visible, 61%) and the palmar scapholunate ligaments (partially visible, 12%; completely visible, 81%) were more difficult to recognize. US may

  12. Ligament-induced sacral fractures of the pelvis are possible.

    Science.gov (United States)

    Steinke, Hanno; Hammer, Niels; Lingslebe, Uwe; Höch, Andreas; Klink, Thomas; Böhme, Jörg

    2014-07-01

    Pelvic ring stability is maintained passively by both the osseous and the ligamentous apparatus. Therapeutic approaches focus mainly on fracture patterns, so ligaments are often neglected. When they rupture along with the bone after pelvic ring fractures, disrupting stability, ligaments need to be considered during reconstruction and rehabilitation. Our aim was to determine the influence of ligaments on open-book injury using two experimental models with body donors. Mechanisms of bone avulsion related to open-book injury were investigated. Open-book injuries were induced in human pelves and subsequently investigated by anatomical dissection and endoscopy. The findings were compared to CT and MRI scans of open-book injuries. Relevant structures were further analyzed using plastinated cross-sections of the posterior pelvic ring. A fragment of the distal sacrum was observed, related to open-book injury. Two ligaments were found to be responsible for this avulsion phenomenon: the caudal portion of the anterior sacroiliac ligament and another ligament running along the ventral surface of the third sacral vertebra. The sacral fragment remained attached to the coxal bone by this second ligament after open-book injury. These results were validated using plastination and the structures were identified. Pelvic ligaments are probably involved in sacral avulsion caused by lateral traction. Therefore, ligaments should to be taken into account in diagnosis of open-book injury and subsequent therapy. Copyright © 2014 Wiley Periodicals, Inc.

  13. Evaluation of Transsyndesmotic Fixation and Primary Deltoid Ligament Repair in Ankle Fractures With Suspected Combined Deltoid Ligament Injury.

    Science.gov (United States)

    Wu, Kai; Lin, Jian; Huang, Jianhua; Wang, Qiugen

    2018-04-13

    The present prospective study examined the utility of the intraoperative tap test/technique for distal tibiofibular syndesmosis in the diagnosis of deltoid ligament rupture and compared the outcomes of transsyndesmotic fixation to deltoid ligament repair with suture anchor. This diagnostic technique was performed in 59 ankle fractures with suspected deltoid ligament injury. The width of the medial clear space of 59 cases was evaluated to assess the sensitivity and specificity. Those with deltoid ligament rupture were randomly assigned to 2 groups and treated with deltoid ligament repair with a suture anchor or with syndesmosis screw fixation. All the patients were assessed with the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, short-form 36-item questionnaire (SF-36), and visual analog scale (VAS). The tap test was positive in 53 cases. However, surgical exploration demonstrated that 51 cases (86.4%) had a combined deltoid ligament injury and fracture. The sensitivity and specificity of the tap test was 100.0% and 75.0%, respectively. Finally, 26 cases (96.3%) in the syndesmosis screw group and 22 (91.7%) in the deltoid repair group were followed up. No statistically significant differences were found in the AOFAS ankle-hindfoot scale score, SF-36 score, or VAS score between the 2 groups. The malreduction rate in the syndesmosis screw group was 34.6% and that in the deltoid repair group was 9.09%. The tap test is an intraoperative diagnostic method to use to evaluate for deltoid ligament injury. Deltoid ligament repair with a suture anchor had good functional and radiologic outcomes comparable to those with syndesmotic screw fixation but has a lower malreduction rate. We did not encounter the issue of internal fixation failure or implant removal. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. MR imaging features of chronically torn anterior cruciate ligament

    International Nuclear Information System (INIS)

    Niitsu, Mamoru; Kuramochi, Masashi; Ikeda, Kotaroh; Fukubayashi, Tohru; Anno, Izumi; Itai, Yuji

    1995-01-01

    Magnetic resonance (MR) images of 40 knee joints with arthroscopically proved chronic anterior cruciate ligament (ACL) tears were retrospectively evaluated. MRI demonstrated various features of chronic ACL tears: 19 knees revealed with no identifiable ligamentous structure, and 21 had residual ligamentous structures. These pseudoligaments, 14 discontinuous bands and seven continuous bands with elongation, were residual torn ligamentous fibers and/or synovial tissues. All the discontinuous bands were disrupted from the femoral attachment and were likely to traverse the lower intercondylar space. Six disrupted ligaments were attached to the lateral aspect of the posterior cruciate ligament (PCL). Coronal T2 * -weighted gradient echo images showed better delineation of the disrupted femoral attachment and adhesion to the PCL. A chronic ACL tear with minimal elongation or with PCL attachment at a higher position may occasionally be difficult to distinguish from an intact ligament. (author)

  15. The fibre bundle anatomy of human cruciate ligaments

    NARCIS (Netherlands)

    Mommersteeg, T. J.; Kooloos, J. G.; Blankevoort, L.; Kauer, J. M.; Huiskes, R.; Roeling, F. Q.

    1995-01-01

    The cruciate ligaments of the knee consist of numerous fascicles, groups of which comprise fibre bundles. The stabilising function of these ligaments is established by changes in the lengths and orientations of the fascicles. Understanding the function of knee ligaments thus requires an

  16. The medial collateral ligament of the elbow joint

    DEFF Research Database (Denmark)

    Floris, S; Olsen, Bo Sanderhoff; Dalstra, Michel

    1998-01-01

    Eighteen osteoligamentous elbow joint specimens were included in a study of the medial collateral ligament complex (MCL). The morphologic characteristics of the MCL were examined, and three-dimensional kinematic measurements were taken after selective ligament dissections were performed. On morph......Eighteen osteoligamentous elbow joint specimens were included in a study of the medial collateral ligament complex (MCL). The morphologic characteristics of the MCL were examined, and three-dimensional kinematic measurements were taken after selective ligament dissections were performed...

  17. LAr calorimeter for SCC with a common vacuum bulkhead---a concept to improve hermeticity

    International Nuclear Information System (INIS)

    Pope, W.L.; Watt, R.D.

    1989-11-01

    A new concept for a Barrel/Endcap LAr Calorimeter (LAC) is described in which the Barrel and Endcaps are in separate vacuum enclosures but share a common vacuum bulkhead (CVB). We explore 2 possible bulkhead construction types; welded plate sandwich panels, and brazed sandwich panels in which the core is an isotropic cellular solid--foamed aluminum. Gas lines and electric cables from he innermost Drift Chamber pass through radial holes in the core of the sandwich bulkhead. The CVB concept offers the potential to obtain a more hermetic calorimeter with significantly reduced dead material and/or space in the interface region common to conventional design LAr detectors for the SSC with Endcap features. To utilize a common additional steps to remove the Drift Chamber, a large increase in Endcap standby heat leak, and perhaps, new cryogenic safety issues. We find that significant amount of dead mass can be removed from critical regions of the vacuum shells when compared to a promising SSC LAC reference design. It is also shown that the increased standby heat leak of this concept can be easily removed by existing cooling capacity in another large LAr calorimeter. It is further shown that shut-downs need not be appreciably longer. Finally, it is argued that cryogen spill hazards can be avoided if the Endcap's LAr is removed during Drift chamber maintenance shutdowns, and that cryogenic safety is not compromised

  18. Lateral collateral ligament of the elbow joint

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1996-01-01

    The structure and kinematics of the lateral collateral ligament of the elbow joint were investigated in 10 cadaveric specimens. The lateral collateral ligament was observed to be a distinct part of the lateral collateral ligament complex. It contains posterior fibers that pass through the annular....... Division of the posterolateral capsule caused no further laxity. Cutting the lateral collateral ligament induced a maximum laxity of 11.8 degrees at 110 degrees of flexion in forced varus and a maximum laxity of 20.6 degrees at 110 degrees of flexion in forced external rotation. The corresponding maximal...... posterior radial head translation was observed at 80 degrees to 100 degrees of flexion and was 5.7 mm in forced varus and 8.1 mm in forced external rotation. This study suggests the lateral collateral ligament to be an important stabilizer of the humeroulnar joint and the radial head in forced varus...

  19. Tissue engineered devices for ligament repair, replacement and ...

    African Journals Online (AJOL)

    PRECIOUS

    2009-12-29

    Dec 29, 2009 ... These devices use a wide variety of materials and designs to replicate ligament mechanics and allow for new tissue regeneration. Key words: Anterior cruciate ligament (ACL), tissue engineering, cells, tensile, stress relaxation, polymer, allograft, xenograft. INTRODUCTION. The anterior cruciate ligament ...

  20. Syndesmosis and deltoid ligament injuries in the athlete

    NARCIS (Netherlands)

    McCollum, Graham A.; van den Bekerom, Michel P. J.; Kerkhoffs, Gino M. M. J.; Calder, James D. F.; van Dijk, C. Niek

    2013-01-01

    Injury to the syndesmosis and deltoid ligament is less common than lateral ligament trauma but can lead to significant time away from sport and prolonged rehabilitation. This literature review will discuss both syndesmotic and deltoid ligament injuries without fracture in the professional athlete. A

  1. Operation plan for the data 100/LARS terminal system

    Science.gov (United States)

    Bowen, A. J., Jr.

    1980-01-01

    The Data 100/LARS terminal system provides an interface for processing on the IBM 3031 computer system at Purdue University's Laboratory for Applications of Remote Sensing. The environment in which the system is operated and supported is discussed. The general support responsibilities, procedural mechanisms, and training established for the benefit of the system users are defined.

  2. Bioengineered anterior cruciate ligament

    Science.gov (United States)

    Martin, Ivan (Inventor); Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  3. Radiologic analysis of the medical collateral ligament rupture

    International Nuclear Information System (INIS)

    Cho, Chung Che; Lee, Chang Jun; Kim, Kun Sang; Park, Soo Soung

    1979-01-01

    The medical collateral ligament rupture is the most common injury involving the knee joint ligaments. The ruptured medical collateral ligaments of 73 cases with clinical and surgical confirmations were radiologically analyzed. The results were obtained as follows: 1. The most risky age for tearing of the medical collateral ligament was third to fifth decades (50 cases of male and 23 of females). 2. The most common cause of the medical collateral ligament rupture was traffic accident (82.2%). 3. The mean distance of medial knee joint space was 7.9 ± 2.0 mm on the normal side and 13.7 ± 4.2 mm on the affected side. 4. The mean degree of knee joint space was 10.1 ± 2.5 on the normal side and 14.7 ± 3.8 on the affected side. 5. The fibula was the bone fractured most frequently in association with the medial collateral ligament rupture (30.6%).

  4. Readout Electronics for the ATLAS LAr Calorimeter at HL-LHC

    CERN Document Server

    Chen, H; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment is one of the two general-purpose detectors designed to study proton-proton collisions (14 TeV in the center of mass) produced at the Large Hadron Collider (LHC) and to explore the full physics potential of the LHC machine at CERN. The ATLAS Liquid Argon (LAr) calorimeters are high precision, high sensitivity and high granularity detectors designed to provide precision measurements of electrons, photons, jets and missing transverse energy. ATLAS (and its LAr Calorimeters) has been operating and collecting p-p collisions at LHC since 2009. The on-detector electronics (front-end) part of the current readout electronics of the calorimeters measures the ionization current signals by means of preamplifiers, shapers and digitizers and then transfers the data to the off-detector electronics (back-end) for further elaboration, via optical links. Only the data selected by the level-1 calorimeter trigger system are transferred, achieving a bandwidth reduction to 1.6 Gbps. The analog trigger sum sig...

  5. Anterolateral Ligament of the Knee Shows Variable Anatomy in Pediatric Specimens.

    Science.gov (United States)

    Shea, Kevin G; Milewski, Matthew D; Cannamela, Peter C; Ganley, Theodore J; Fabricant, Peter D; Terhune, Elizabeth B; Styhl, Alexandra C; Anderson, Allen F; Polousky, John D

    2017-06-01

    Anterior cruciate ligament (ACL) reconstruction failure rates are highest in youth athletes. The role of the anterolateral ligament in rotational knee stability is of increasing interest, and several centers are exploring combined ACL and anterolateral ligament reconstruction for these young patients. Literature on the anterolateral ligament of the knee is sparse in regard to the pediatric population. A single study on specimens younger than age 5 years demonstrated the presence of the anterolateral ligament in only one of eight specimens; therefore, much about the prevalence and anatomy of the anterolateral ligament in pediatric specimens remains unknown. We sought to (1) investigate the presence or absence of the anterolateral ligament in prepubescent anatomic specimens; (2) describe the anatomic relationship of the anterolateral ligament to the lateral collateral ligament; and (3) describe the anatomic relationship between the anterolateral ligament and the physis. Fourteen skeletally immature knee specimens (median age, 8 years; range, 7-11 years) were dissected (12 male, two female specimens). The posterolateral structures were identified in all specimens, including the lateral collateral ligament and popliteus tendon. The presence or absence of the anterolateral ligament was documented in each specimen, along with origin, insertion, and dimensions, when applicable. The relationship of the anterolateral ligament origin to the lateral collateral ligament origin was recorded. The anterolateral ligament was identified in nine of 14 specimens. The tibial attachment point was consistently located in the same region on the proximal tibia, between the fibular head and Gerdy's tubercle; however, the femoral origin of the anterolateral ligament showed considerable variation with respect to the lateral collateral ligament origin. The median femoral origin of the anterolateral ligament was 10 mm (first interquartile 6 mm, third interquartile 13) distal to the distal

  6. Round Ligament Varicosities During Pregnancy: Case Report

    International Nuclear Information System (INIS)

    Baek, Chang Kyu; Oh, Young Taik; Jung, Dae Chul

    2011-01-01

    There are various causes of a painful palpable mass in the groin during pregnancy. The differential diagnoses of an inguinal mass include hernia, lymphadenopathy, mesothelial cyst, cystic lymphangioma, neoplasms (lipoma, leiomyoma and sarcoma), endometriosis, embryonic remnants and round ligament varicosities. Among them, round ligament varicosities can be easily misdiagnosed as an inguinal hernia in a pregnant woman. These lesions should be managed conservatively because they resolve spontaneously during the postpartum period. Ultrasonography can help make the diagnosis of round ligament varicosities and so prevent unnecessary surgical intervention and the associated morbidity. Herein we report on a case of round ligament varicosities that presented during pregnancy and this condition was readily diagnosed via Doppler sonography

  7. Round Ligament Varicosities During Pregnancy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Chang Kyu; Oh, Young Taik; Jung, Dae Chul [Yonsei University Health System, Seoul (Korea, Republic of)

    2011-12-15

    There are various causes of a painful palpable mass in the groin during pregnancy. The differential diagnoses of an inguinal mass include hernia, lymphadenopathy, mesothelial cyst, cystic lymphangioma, neoplasms (lipoma, leiomyoma and sarcoma), endometriosis, embryonic remnants and round ligament varicosities. Among them, round ligament varicosities can be easily misdiagnosed as an inguinal hernia in a pregnant woman. These lesions should be managed conservatively because they resolve spontaneously during the postpartum period. Ultrasonography can help make the diagnosis of round ligament varicosities and so prevent unnecessary surgical intervention and the associated morbidity. Herein we report on a case of round ligament varicosities that presented during pregnancy and this condition was readily diagnosed via Doppler sonography

  8. Anterior cruciate ligament tears: MRI versus arthroscopy

    International Nuclear Information System (INIS)

    Tosch, U.; Felix, R.; Schauwecker, W.; Dreithaler, B.

    1992-01-01

    Because of suspected rupture of the anterior cruciate ligament sixteen acute traumatised patients were investigated by MR and arthroscopy. The MR diagnosis of a lesion of the anterior cruciate ligament proved to be correct by arthroscopy in fifteen of sixteen cases. Diagnostic criteria for lesions of the anterior cruciate ligament were: increased signal intensity in T 1 - and T 2 weighted images, increased volume and discontinuity of ligamentous structures. Additional MR findings of meniscal tears were correct in three of four cases laterally and in four of four cases medially. Femoral cartilage lesions were correctly identified by MR in three cases. MR normal findings proved to be correct by arthroscopy in another five cases. (orig.) [de

  9. Altın Fiyatlarının Yapay Sinir Ağları ile Tahmini ve Bir Uygulama

    Directory of Open Access Journals (Sweden)

    Rıdvan YÜKSEL

    2016-03-01

    Full Text Available Bu çalışmada altın fiyatlarını yapay sinir ağları ile öngörmek amacıyla, altın fiyatlarını etkileyebileceği düşünülen değişkenler olan Gümüş fiyatları, Brent Petrol fiyatları, ABD doları/ EUR paritesi, EuroNext100 endeksi, Amerika Dow Jones Endeksi, 13 Hafta vadeli ABD bonosu faiz oranı ve ABD TÜFE endeksi kullanılarak modeller kurulmuştur. Yapay sinir ağları ile kurulan modellerden elde edilen tahmin sonuçları, gerçek değerler ile R2, RMSE, MAE ve MAPE (% gibi performans kriterleri hesaplanarak karşılaştırılmıştır. Elde edilen bulgular yapay sinir ağlarının altın fiyatlarının tahmininde başarı ile kullanılabileceğini göstermektedir. Yapılan duyarlılık analizinin sonuçları değerlendirildiğinde altın fiyatlarını etkileyen faktörlerin başında gümüş ve petrol fiyatlarının geldiği tespit edilmiştir.

  10. Genetic association analysis of LARS2 with type 2 diabetes

    NARCIS (Netherlands)

    E. Reiling (Erwin); B. Jafar-Mohammadi (Bahram); E. van 't Riet (Esther); M.N. Weedon (Michael); J.V. van Vliet-Ostaptchouk (Jana); T. Hansen (Torben); R. Saxena (Richa); T.W. van Haeften (Timon); P.P. Arp (Pascal); S. Das; M.G.A.A.M. Nijpels (Giel); M.J. Groenewoud (Marlous); E.C. van Hove (Els); A.G. Uitterlinden (André); J.W.A. Smit (Jan); A.D. Morris (Andrew); A.S.F. Doney (Alex); C.N.A. Palmer (Colin); C. Guiducci (Candace); A.T. Hattersley (Andrew); T.M. Frayling (Timothy); O. Pedersen (Oluf); P.E. Slagboom (Eline); D. Altshuler (David); L. Groop (Leif); J.A. Romijn; J.A. Maassen (Johannes); M.A. Hofker (Marten); J.M. Dekker (Jacqueline); M.I. McCarthy (Mark); L.M. 't Hart (Leen)

    2010-01-01

    textabstractAims/hypothesis: LARS2 has been previously identified as a potential type 2 diabetes susceptibility gene through the low-frequency H324Q (rs71645922) variant (minor allele frequency [MAF] 3.0%). However, this association did not achieve genome-wide levels of significance. The aim of this

  11. MORPHOMETRIC STUDY OF MEDIAL COLLATERAL LIGAMENTS OF ANKLE

    Directory of Open Access Journals (Sweden)

    Neelu Prasad

    2016-06-01

    Full Text Available BACKGROUND The ankle joint is one of the most frequently injured joint. A sprained ankle results due to tear of anterior talofibular and calcaneofibular ligaments when the foot is twisted in lateral direction. In forcible eversion of the foot, the deltoid ligament may be torn. At times, the deltoid ligament pulls the medial malleolus thereby causing avulsion fracture of the malleolus. The strong eversion pull on the deltoid ligament causes transverse fracture of medial malleolus. If the tibia is carried anteriorly, the posterior margin of the distal end of the tibia is also broken by the talus producing a trimalleolar fracture. The talocrural joint is a major weight bearing joint of the body. The weight of the body is transmitted from the tibia and fibula to the talus which distributes the weight anteriorly and posteriorly within the foot. One sixth of the static load of the leg is carried by the fibula at the tibiofibular joint. These require a high degree of stability which is determined by the passive and dynamic factors. A sprained ankle results due to tear of anterior talofibular and calcaneofibular ligaments when the foot is twisted in lateral direction. In forcible eversion of the foot, the deltoid ligament may be torn. At times, the deltoid ligament pulls the medial malleolus thereby causing avulsion fracture of the malleolus. The strong eversion pull on the deltoid ligament causes transverse fracture of medial malleolus. If the tibia is carried anteriorly, the posterior margin of the distal end of the tibia is also broken by the talus producing a trimalleolar fracture. Conventionally, X-ray techniques have been used to diagnose ligament injuries. Magnetic resonance (MR imaging has opened new horizons in the diagnosis and treatment of many musculoskeletal diseases of the ankle and foot. It demonstrates abnormalities in the bones and soft tissues before they become evident at other imaging modalities. The anatomy of the deltoid ligament

  12. Meniscotibial (coronary) ligament tears

    International Nuclear Information System (INIS)

    El-Khoury, G.Y.; Usta, H.Y.; Berger, R.A.

    1984-01-01

    Preservation of the meniscus whenever possible is essential in maintaining knee stability and preventing premature osteoarthritis. Peripheral meniscal tears are the most amenable to surgical repair. This study evaluates the peripheral attachments of the medial meniscus and focuses on a specific tear limited to the meniscotibial ligament (coronary ligament). The diagnosis is made arthrographically when the medial meniscus floats above the tibial plateau without separating completely from the capsule. The lateral meniscus is rarely involved in this type of injury. (orig.)

  13. Tissue engineering of ligaments: a comparison of bone marrow stromal cells, anterior cruciate ligament, and skin fibroblasts as cell source.

    Science.gov (United States)

    Van Eijk, F; Saris, D B F; Riesle, J; Willems, W J; Van Blitterswijk, C A; Verbout, A J; Dhert, W J A

    2004-01-01

    Anterior cruciate ligament (ACL) reconstruction surgery still has important problems to overcome, such as "donor site morbidity" and the limited choice of grafts in revision surgery. Tissue engineering of ligaments may provide a solution for these problems. Little is known about the optimal cell source for tissue engineering of ligaments. The aim of this study is to determine the optimal cell source for tissue engineering of the anterior cruciate ligament. Bone marrow stromal cells (BMSCs), ACL, and skin fibroblasts were seeded onto a resorbable suture material [poly(L-lactide/glycolide) multifilaments] at five different seeding densities, and cultured for up to 12 days. All cell types tested attached to the suture material, proliferated, and synthesized extracellular matrix rich in collagen type I. On day 12 the scaffolds seeded with BMSCs showed the highest DNA content (p engineered ligament.

  14. Brüssel Euroopa pealinnaks? / Ülar Mark

    Index Scriptorium Estoniae

    Mark, Ülar, 1968-

    2009-01-01

    Brüsseli Euroopa kvartali planeerimisvõistlusest, mille peakorraldaja oli Brüsseli pealinna piirkond koos Brüsseli linna ja Euroopa Komisjoniga. Eestist osales žüriis arhitekt Ülar Mark. Meeskonna Atelier Christian de Portzamparc võidutööst ja teiste teise vooru pääsenud nelja meeskonna (JDS / Julien De Smedt Architects, OMA / Office for Metropolitan Architecture, Xaveer De Geyter Architect, Fletcher Priest Architects) töödest

  15. MRI assessment of mid-urethral ligament changes in female stress urinary incontinence

    International Nuclear Information System (INIS)

    Bai Mei; Liu Hongyi; Han Yue; Xu Guoping; Fang Ping; Zhao Yang; Li Jingjin

    2012-01-01

    Objective: To evaluate the MRI value in changes of mid-urethral ligament injury of female stress urinary incontinence (SUI). Methods: Comparison of MRI changes of mid-urethral ligament on 30 healthy female volunteers and 20 female SUI patients. Chi-square test was used to compare the form of SUI patient's mid-urethral support ligaments. Results: The female mid-urethral support ligaments were composed of 4 groups of ligaments, including the periurethral ligament and pubourethral ligaments (1 pair), and at both sides of the urethra's paraurethral ligaments (1 pair) and suburethral ligament lying dorsal urethra, connecting the urethra and pelvic arcus tendinous fasciae. In normal MRI, ligament was a thin strip and showed low signal on both T 1 WI and T 2 WI, T 2 WI sagittal and cross-section scan was the best combination to show the middle urethral support ligaments changes, with tension; 6 patients (20%) in the 30 patients normal control group could be seen tortuously and slack like around the urethra ligaments. Twenty SUI patients mid-urethral support ligaments were performance laxity or rupture,rates were 39% (47/120) and 42% (50/120) (χ 2 =43.191, P<0.05). On T 2 WI, the ligamentous laxity was floating,and loss tension, also could performance one side extension and thinner than the other side. The ligament rupture was performance of the signal interruption, ligament contracture and one end of ligament attachment points separation. Conclusion: MRI can objective effective evaluate the mid-urethral support ligaments' pathological changes in stress urinary incontinence patients. (authors)

  16. Application of SDSM and LARS-WG for simulating and downscaling of rainfall and temperature

    Science.gov (United States)

    Hassan, Zulkarnain; Shamsudin, Supiah; Harun, Sobri

    2014-04-01

    Climate change is believed to have significant impacts on the water basin and region, such as in a runoff and hydrological system. However, impact studies on the water basin and region are difficult, since general circulation models (GCMs), which are widely used to simulate future climate scenarios, do not provide reliable hours of daily series rainfall and temperature for hydrological modeling. There is a technique named as "downscaling techniques", which can derive reliable hour of daily series rainfall and temperature due to climate scenarios from the GCMs output. In this study, statistical downscaling models are used to generate the possible future values of local meteorological variables such as rainfall and temperature in the selected stations in Peninsular of Malaysia. The models are: (1) statistical downscaling model (SDSM) that utilized the regression models and stochastic weather generators and (2) Long Ashton research station weather generator (LARS-WG) that only utilized the stochastic weather generators. The LARS-WG and SDSM models obviously are feasible methods to be used as tools in quantifying effects of climate change condition in a local scale. SDSM yields a better performance compared to LARS-WG, except SDSM is slightly underestimated for the wet and dry spell lengths. Although both models do not provide identical results, the time series generated by both methods indicate a general increasing trend in the mean daily temperature values. Meanwhile, the trend of the daily rainfall is not similar to each other, with SDSM giving a relatively higher change of annual rainfall compared to LARS-WG.

  17. Characterization and role of the immune response during ligament healing

    Science.gov (United States)

    Chamberlain, Connie S.

    Scar formation of ligaments after rupture remains a great challenge. Ligament healing involves a complex, coordinated series of events that form a neo-ligament, which is more disorganized and fibrotic in character than the native tissue. The repair process may extend from months to years, and the injured ligament never fully recovers its original mechanical properties. With little intrinsic healing potential, ruptures of the anterior cruciate ligament (ACL) are usually reconstructed. The "healed" tissues, however, do not regenerate native tissues or recapitulate their mechanical function. ACL grafts often lengthen (incidents range from 40-100%) and their strength can drop by ˜50% after remodeling. Reconstructed knees are often less stable and fail to restore normal joint kinematics. Our overall goal is to improve healing, making ligaments more regenerative. The first 2 studies characterized ligament healing in a spatial and temporal manner over 28 days. The experiments demonstrated creeping substitution and the potential role of the immune system to control the repair and/or regenerative process. From these studies, macrophages were identified as significant players during healing. Macrophages paralleled creeping substitution, were abundant within the healing ligament, and potentially played a destructive role via matrix phagocytosis. The role of macrophages during early ligament healing was then evaluated using liposome-encapsulated clodronate to inhibit phagocytosing macrophages. Clodronate attenuated the early infiltration of macrophages, resulting in delayed structural and functional healing. Macrophage re-infiltration into the wound resulted in continued ligament healing. These results suggested that early inhibition of phagocytosing macrophages is detrimental to ligament healing. The final experiment evaluated the effects of interleukin-4 on ligament healing. Interleukin-4 (IL-4) is reported to stimulate the Th2 lymphocyte/M2 macrophage pathway, reducing

  18. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    Science.gov (United States)

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  19. Anterolateral ligament abnormalities in patients with acute anterior cruciate ligament rupture are associated with lateral meniscal and osseous injuries

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, Pieter van; Smet, Eline de; Gielen, Jan L.; Parizel, Paul M. [Antwerp University Hospital and University of Antwerp, Department of Radiology, Antwerp (Belgium); Clockaerts, Stefan [University College Hospitals, Department of Orthopaedics, London (United Kingdom); Vanhoenacker, Filip M. [Antwerp University Hospital and University of Antwerp, Department of Radiology, Antwerp (Belgium); Ghent University Hospital and University of Ghent, Department of Radiology, Ghent (Belgium); AZ St-Maarten, Department of Radiology, Antwerp (Belgium); Lambrecht, Valerie [Ghent University Hospital and University of Ghent, Department of Radiology, Ghent (Belgium); Wouters, Kristien [Antwerp University Hospital and University of Antwerp, Department of Biostatistics, Antwerp (Belgium)

    2016-10-15

    To determine the frequency of anterolateral ligament (ALL) injury in patients with acute anterior cruciate ligament (ACL) rupture and to analyse its associated injury patterns. Ninety patients with acute ACL rupture for which MRI was obtained within 8 weeks after the initial trauma were retrospectively identified. Two radiologists assessed the status of the ALL on MRI by consensus. The presence or absence of an ALL abnormality was compared with the existence of medial and lateral meniscal tears diagnosed during arthroscopy. Associated collateral ligament and osseous injuries were documented with MRI. Forty-one of 90 knees (46 %) demonstrated ALL abnormalities on MRI. Of 49 knees with intact ALL, 15 (31 %) had a torn lateral meniscus as compared to 25 torn lateral menisci in 41 knees (61 %) with abnormal ALL (p = 0.008). Collateral ligament (p ≤ 0.05) and osseous injuries (p = 0.0037) were more frequent and severe in ALL-injured as compared with ALL-intact knees. ALL injuries are fairly common in patients with acute ACL rupture and are statistically significantly associated with lateral meniscal, collateral ligament and osseous injuries. (orig.)

  20. [Studies on the mechanical properties of the knee ligament].

    Science.gov (United States)

    Kubotera, D

    1987-04-01

    To study mechanical properties of the knee ligaments, tension tests at various speeds were performed on the knee of a dog with only the collateral ligament. The results showed that the tensile force was greater in high speed than in low speed test. The difference may be caused in a viscous property of the ligament. The mechanical properties of ligaments can therefore be treated as those of viscoelastic materials and expressed by a modified Voigt model consisting of a non-linear spring element and a dash pot component. Observations regarding the ultrastructure of human knee ligaments using an electron scanning microscope revealed wavy bundles of collagen fiber connected with coarse fibers like network running in parallel with the long axis as the main structure. The above structure and properties were considered to be the decisive factors in the mechanical actions of the knee ligament.

  1. Strain Distribution in the Anterior Inferior Tibiofibular Ligament, Posterior Inferior Tibiofibular Ligament, and Interosseous Membrane Using Digital Image Correlation.

    Science.gov (United States)

    Xu, Daorong; Wang, Yibei; Jiang, Chunyu; Fu, Maoqing; Li, Shiqi; Qian, Lei; Sun, Peidong; Ouyang, Jun

    2018-05-01

    Ligament repair and augmentation techniques can stabilize syndesmosis injuries. However, little is known about the mechanical behavior of syndesmotic ligaments. The aim of this study was to analyze full-field strain, strain trend under foot rotation, and subregional strain differences of the anterior inferior tibiofibular ligament (AITFL), posterior inferior tibiofibular ligament (PITFL), and interosseous membrane (IOM). Eleven fresh-frozen lower limbs were dissected to expose the AITFL, PITFL, and IOM. The foot underwent rotation from 0° to 25° internal and 35° external, with 3 ankle positions (neutral, 15° dorsiflexion, and 25° plantarflexion) and a vertical load of 430 N. Ligament strain was recorded using digital image correlation. The mean strain on the AITFL with 35° external rotation was greater in the proximal portion compared with distal portion in the neutral position ( P = .009) and dorsiflexion ( P = .003). The mean strain in the tibial insertion and midsubstance near tibial insertion were greater when compared with other regions ( P = .018 and P = .009). The subregions of mean strain in the PITFL and IOM groups were not significantly different. The strain trend of AITFL, PITFL, and IOM showed common transformation, just when the foot was externally rotated. The findings of this study show that a significantly high strain was observed on the proximal part and the midsubstance near the Chaput tubercle of the AITFL when the ankle was externally rotated. All 3 ligaments resisted the torque in the syndesmosis by external rotation of the foot. This study allows for better understanding of the mechanical behavior of the syndesmosis ligaments, which could influence the repair technique and AITFL augmentation techniques.

  2. Peynirlere Kontamine Olan Küflerin Bazı Esansiyel Yağlar ile İnhibisyonu

    Directory of Open Access Journals (Sweden)

    Sibel Özçakmak

    2015-02-01

    Full Text Available Küf kontaminasyonu önemli kalite problemlerine ve peynir üreticilerine ekonomik kayıplara neden olmaktadır. Peynirlerden yaygın olarak izole edilen kontamine küf türleri Penicillium commune, P. verrucosum, P. roqueforti, P. palitans, Aspergillus flavus ve Geotrichum candidum olarak belirlenmiştir. Sorbik asit veya bunların tuzları, bozulma etmeni küflerin önlenmesi için peynir yüzeylerine uygulanmaktadır. Bazı sentetik gıda katkılarının kullanımıyla ilgili gıda endüstrisi ve mevzuatı oluşturan kuruluşlar tarafından getirilen kısıtlamalar doğal antimikrobiyel bileşikler üzerine araştırmaların doğmasına neden olmuştur. Bitki ve baharat, gıdaların mikrobiyolojik güvenliğini sağlayan etkili bileşiklere sahiptir. Salvia officinalis (ada çayı, Laurus nobilis (defne, Cinnamomum zeylanicum (tarçın, Thymus vulgaris (kekik, Cymbopogon citratus (limon otu, Origanum vulgare (keklik otu esansiyel yağları, bozulma etmeni küf şorasını inhibe edebilmiştir. Thymol ve karanfil esansiyel yağlarının Çedar peynirinde P. citrinum, Kaşar peynirinde A. flavus; zeytin yaprağı ekstraklarının, Tulum peynirinde A. niger, P. citrinum ve P. roqueforti, beyaz peynirde Mucor rocemosus’un gelişimini inhibe edebildiği bildirilmiştir.

  3. ATLAS LAr Calorimeter Performance and Commissioning for LHC Run-2

    CERN Document Server

    Spettel, Fabian; The ATLAS collaboration

    2015-01-01

    The ATLAS detector was designed and built to study proton-proton colli- sions produced at the LHC at centre-of-mass energies up to 14 TeV and in- stantaneous luminosities up to $10^{34} \\text{cm}^{-2} \\text{s}^{-1}$. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region $|\\eta|<3.2$, and for hadronic calorimetry in the region from $|\\eta|=1.5$ to $|\\eta|=4.9$. In the first LHC run a total luminosity of 27 $\\text{fb}^{-1}$ as been collected at center-of-mass energies of 7-8 TeV with very high operational efficiency of the LAr Calorimeters and excellent performance. The well calibrated and highly granular detector achieved its design values both in energy measurement as well as in direction resolution, which was a main ingredient for the successul discovery of a Higgs boson in the di-photon decay channel. The talk will give an overview of the procedures applied to calibrate the 180.000 read-out channels electronically as well as from using refe...

  4. The WA105-3x1x1 m3 dual phase LAr-TPC demonstrator

    CERN Document Server

    Murphy, Sebastien

    2016-11-15

    The dual phase Liquid Argon Time Projection Chamber (LAr TPC) is the state-of-art technology for neutrino detection thanks to its superb 3D tracking and calorimetry performance. Its main feature is the charge amplification in gas argon which provides excellent signal-to-noise ratio. Electrons produced in the liquid argon are extracted in the gas phase. Here, a readout plane based on Large Electron Multiplier detectors provides amplification of the charges before its collection onto an anode with strip readout. The charge amplification enables constructing fully homoge- nous giant LAr-TPCs with tuneable gain, excellent charge imaging performance and increased sensitivity to low energy events. Following a staged approach the WA105 collaboration is con- structing a dual phase LAr-TPC with an active volume of 3x1x1m3 that will soon be tested with cosmic rays. Its construction and operation aims to test scalable solutions for the crucial aspects of this technology: ultra high argon purity in non-evacuable tank, la...

  5. MRI of the lateral ankle ligaments: value of three-dimensional orientation

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Breitenseher, M.J.

    2003-01-01

    Purpose: To determine the three-dimensional orientation of the lateral ankle ligaments with MRI. Materials and Methods: Twenty healthy volunteers without previous injury to the ankle were included in the study. With the right ankle in the normal anatomic position stabilized in a splint, coronal T2-weighted spin-echo sequences (TSE) were obtained. The three-dimensional orientation was determined by placing paths through the ligaments and by measuring the angles between corresponding tangents and the three main imaging planes. Results: Using the calculated angles, full-length visualization of the lateral ligaments of the ankle was achieved. The angles deviating from the axial imaging plane were 18.0 degrees for the anterior talofibular ligament, 52.3 degrees for the calcaneofibular ligament and 28.2 degrees for the posterior talofibular ligament. Conclusion: MRI enables the exact determination of the three-dimensional orientation of the lateral ankle ligaments. Orienting the imaging planes according to the calculated angular deviation allows the full-length visualization of the ligaments and is the basis for optimal imaging of the lateral ankle ligaments. (orig.) [de

  6. Injury of the ankle joint ligaments

    International Nuclear Information System (INIS)

    Breitenseher, M.J.

    2007-01-01

    The diagnosis of lateral collateral ankle ligament trauma is based on patient history, clinical examination and clinical stress tests. If the clinical stress test is positive, stress radiography can be performed. There is, however, no consensus about the usefulness of stress radiography in acute ankle sprain, and in particular about the cut-off talar tilt angle beyond which a two-ligament rupture would be certain, ranging from 5 to 30 . Today, magnetic resonance imaging (MRI) is not used in this area, although it does allow controlled positioning of the foot and defined section visualization of injured lateral collateral ankle ligaments. In acute and chronic sinus tarsi injuries, MRI forms the established basis for diagnostic imaging, and can provide a definitive answer in most cases. MRI is also the method of choice for chronic posttraumatic pain with anterolateral impingement after rupture of the anterior talofibular ligament. Generally, for the evaluation of acute ankle injuries, MRI has developed to be the most important second-step procedure when projection radiology is non-diagnostic. (orig.) [de

  7. Stiffness of the ligaments of the human wrist joint

    NARCIS (Netherlands)

    Savelberg, H.H.C.M.; Kooloos, J.G.M.; Huiskes, H.W.J.; Kauer, J.M.G.

    1992-01-01

    The stiffnesses of the superficial ligaments of 14 human cadaver wrist joints have been determined. In these experiments the tested, fresh-frozen carpal joints are divided into a number of bone-ligament-bone complexes, which are loaded in a tensile testing machine at a rate of 66% of the ligaments'

  8. Comparative histology of mouse, rat, and human pelvic ligaments.

    Science.gov (United States)

    Iwanaga, Ritsuko; Orlicky, David J; Arnett, Jameson; Guess, Marsha K; Hurt, K Joseph; Connell, Kathleen A

    2016-11-01

    The uterosacral (USL) and cardinal ligaments (CL) provide support to the uterus and pelvic organs, and the round ligaments (RL) maintain their position in the pelvis. In women with pelvic organ prolapse (POP), the connective tissue, smooth muscle, vasculature, and innervation of the pelvic support structures are altered. Rodents are commonly used animal models for POP research. However, the pelvic ligaments have not been defined in these animals. In this study, we hypothesized that the gross anatomy and histological composition of pelvic ligaments in rodents and humans are similar. We performed an extensive literature search for anatomical and histological descriptions of the pelvic support ligaments in rodents. We also performed anatomical dissections of the pelvis to define anatomical landmarks in relation to the ligaments. In addition, we identified the histological components of the pelvic ligaments and performed quantitative analysis of the smooth muscle bundles and connective tissue of the USL and RL. The anatomy of the USL, CL, and RL and their anatomical landmarks are similar in mice, rats, and humans. All species contain the same cellular components and have similar histological architecture. However, the cervical portion of the mouse USL and RL contain more smooth muscle and less connective tissue compared with rat and human ligaments. The pelvic support structures of rats and mice are anatomically and histologically similar to those of humans. We propose that both mice and rats are appropriate, cost-effective models for directed studies in POP research.

  9. The sacroiliac part of the iliolumbar ligament

    NARCIS (Netherlands)

    A.L. Pool-Goudzwaard (Annelies); G.J. Kleinrensink (Gert Jan); C.J. Snijders (Chris); C.A. Entius; R. Stoeckart (Rob)

    2001-01-01

    textabstractThe iliolumbar ligament has been described as the most important ligament for restraining movement at the lumbosacral junction. In addition, it may play an important role in restraining movement in the sacroiliac joints. To help understand its presumed restraining

  10. Magnetic resonance imaging of ankle ligaments and tendon injuries

    International Nuclear Information System (INIS)

    Breitenseher, M.; Trattnig, S.; Kukla, C.; Daebler, C.; Helbich, T.; Haller, J.; Imhof, H.

    1995-01-01

    Today MRI allows evaluation of the integrity of injured ankle ligaments. The major difficulty in MRI is inconsistency in visualization by inadequate appreciation of the three-dimensional orientation of each ankle ligament. Using this technique, 52 patients with sprained ankles underwent MRI. The integrity of rupture of the collateral lateral ligaments was obtained in all 52 ankles. Full-lenght visualization is essential for evaluation of the ankle ligaments with MRI. In these 52 patients the angle of tilt on the stress X-ray was compared with the rate of MRI findings showing an injury affecting two ligaments. We found that none of the patients in whom the angle of lateral tilt was less than 5 had rupture of two laterial ligaments, while 32% of patients with angles of tilt of 6-14 and 42% of those with angles of tilt over 15 on stress X-ray had two ruptured lateral ligaments. The advantages of MRI are that it offers the best visualization of the extent of the tendon lesion. MRI, however, seems to be superior to US in detecting and quantifying lesions of the Achilles tendon. Therefore, MRI may be indicated in particularly difficult cases of tendons injuries in the foot. (orig.) [de

  11. Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS)

    DEFF Research Database (Denmark)

    Roemer, Frank W; Frobell, Richard; Lohmander, Stefan

    2014-01-01

    OBJECTIVE: To develop a whole joint scoring system, the Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS), for magnetic resonance imaging (MRI)-based assessment of acute anterior cruciate ligament (ACL) injury and follow-up of structural sequelae, and to assess its reliability. DESIGN...

  12. Anterior cruciate ligament-derived cells have high chondrogenic potential.

    Science.gov (United States)

    Furumatsu, Takayuki; Hachioji, Motomi; Saiga, Kenta; Takata, Naoki; Yokoyama, Yusuke; Ozaki, Toshifumi

    2010-01-01

    Anterior cruciate ligament (ACL)-derived cells have a character different from medial collateral ligament (MCL)-derived cells. However, the critical difference between ACL and MCL is still unclear in their healing potential and cellular response. The objective of this study was to investigate the mesenchymal differentiation property of each ligament-derived cell. Both ligament-derived cells differentiated into adipogenic, osteogenic, and chondrogenic lineages. In chondrogenesis, ACL-derived cells had the higher chondrogenic property than MCL-derived cells. The chondrogenic marker genes, Sox9 and alpha1(II) collagen (Col2a1), were induced faster in ACL-derived pellets than in MCL-derived pellets. Sox9 expression preceded the increase of Col2a1 in both pellet-cultured cells. However, the expression level of Sox9 and a ligament/tendon transcription factor Scleraxis did not parallel the increase of Col2a1 expression along with chondrogenic induction. The present study demonstrates that the balance between Sox9 and Scleraxis have an important role in the chondrogenic differentiation of ligament-derived cells. Copyright 2009 Elsevier Inc. All rights reserved.

  13. Tissue engineering of ligaments for reconstructive surgery.

    Science.gov (United States)

    Hogan, MaCalus V; Kawakami, Yohei; Murawski, Christopher D; Fu, Freddie H

    2015-05-01

    The use of musculoskeletal bioengineering and regenerative medicine applications in orthopaedic surgery has continued to evolve. The aim of this systematic review was to address tissue-engineering strategies for knee ligament reconstruction. A systematic review of PubMed/Medline using the terms "knee AND ligament" AND "tissue engineering" OR "regenerative medicine" was performed. Two authors performed the search, independently assessed the studies for inclusion, and extracted the data for inclusion in the review. Both preclinical and clinical studies were reviewed, and the articles deemed most relevant were included in this article to provide relevant basic science and recent clinical translational knowledge concerning "tissue-engineering" strategies currently used in knee ligament reconstruction. A total of 224 articles were reviewed in our initial PubMed search. Non-English-language studies were excluded. Clinical and preclinical studies were identified, and those with a focus on knee ligament tissue-engineering strategies including stem cell-based therapies, growth factor administration, hybrid biomaterial, and scaffold development, as well as mechanical stimulation modalities, were reviewed. The body of knowledge surrounding tissue-engineering strategies for ligament reconstruction continues to expand. Presently, various tissue-engineering techniques have some potential advantages, including faster recovery, better ligamentization, and possibly, a reduction of recurrence. Preclinical research of these novel therapies continues to provide promising results. There remains a need for well-designed, high-powered comparative clinical studies to serve as a foundation for successful translation into the clinical setting going forward. Level IV, systematic review of Level IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Acromioclavicular joint reconstruction with coracoacromial ligament transfer using the docking technique

    Directory of Open Access Journals (Sweden)

    Gobezie Reuben

    2009-01-01

    Full Text Available Abstract Background Symptomatic Acromioclavicular (AC dislocations have historically been surgically treated with Coracoclavicular (CC ligament reconstruction with transfer of the Coracoacromial (CA ligament. Tensioning the CA ligament is the key to success. Methods Seventeen patients with chronic, symptomatic Type III AC joint or acute Type IV and V injuries were treated surgically. The distal clavicle was resected and stabilized with CC ligament reconstruction using the CA ligament. The CA ligament was passed into the medullary canal and tensioned, using a modified 'docking' technique. Average follow-up was 29 months (range 12–57. Results Postoperative ASES and pain significantly improved in all patients (p = 0.001. Radiographically, 16 (94% maintained reduction, and only 1 (6% had a recurrent dislocation when he returned to karate 3 months postoperatively. His ultimate clinical outcome was excellent. Conclusion The docking procedure allows for tensioning of the transferred CA ligament and healing of the ligament in an intramedullary bone tunnel. Excellent clinical results were achieved, decreasing the risk of recurrent distal clavicle instability.

  15. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    Science.gov (United States)

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  16. Correlation between bone contusion and ligament, menisci injury of knee joint

    International Nuclear Information System (INIS)

    Zhang Lijuan; Li Pei; Tu Changzhuo; Wu Guangren; Qi Yuliang; Yan Xiaoqun

    2004-01-01

    Objective: To evaluate the correlation between bone contusion and ligament, meniscus injury of knee joint with MR imaging. Methods: Thirty-five patients with acute trauma of knee joint were studied retrospectively. All eases showed negative on X-ray and bone cont, -sion on MR imaging. Results: in all patients, ligament and meniscus injury were seen in 25 cases (71%), incorporate anterior cruciate ligament injury in 12 cases, posterior cruciate ligament in 6, tibial collateral ligament in 8 cases, fibular collateral ligament in 6 cases, medial meniscus tear in 4 cases, lateral meniscus tear in 5 cases, and hydrops in 29 cases. There were only 3 patients with ligament or meniscus injury but no bone contusion during the same period. Conclusion: It is necessary to check by MR for the patients with acute trauma of knee joint, who have clinical symptom such as ache, swelling, move un-freely showing bone contusion on MR Imaging but without any abnormality on X-ray in order to avoid failure in diagnosing injury of ligament and meniscus. (authors)

  17. Aladağlar da Bitki Formasyonları ve Dağılışları

    OpenAIRE

    ÜNALDI, Ülkü ESER; TOROĞLU, Emin

    2007-01-01

    Bulunduğu konum itibariyle Türkiye\\'de yetişme şartlarının bitki gelişimine ve çeşitliliğine uygun koşullar taşıdığı yerlerden biri de Aladağlar\\'dır. Nitekim dağda orman, çalı ve ot formasyonları yer almaktadır. Orman formasyonu kuru ormanlar ve yarı nemli ormanlar olmak üzere ikiye ayrılmaktadır. Kuru ormanlar güney yamaçta 250-1300mler, kuzey yamaçta 1400–2400 mler arasında uzanmaktadır. Kuru ormanların hakim elemanları güney yamaçlarda kızılçam, kuzey yamaçlarda i...

  18. A real-time computational model for estimating kinematics of ankle ligaments.

    Science.gov (United States)

    Zhang, Mingming; Davies, T Claire; Zhang, Yanxin; Xie, Sheng Quan

    2016-01-01

    An accurate assessment of ankle ligament kinematics is crucial in understanding the injury mechanisms and can help to improve the treatment of an injured ankle, especially when used in conjunction with robot-assisted therapy. A number of computational models have been developed and validated for assessing the kinematics of ankle ligaments. However, few of them can do real-time assessment to allow for an input into robotic rehabilitation programs. An ankle computational model was proposed and validated to quantify the kinematics of ankle ligaments as the foot moves in real-time. This model consists of three bone segments with three rotational degrees of freedom (DOFs) and 12 ankle ligaments. This model uses inputs for three position variables that can be measured from sensors in many ankle robotic devices that detect postures within the foot-ankle environment and outputs the kinematics of ankle ligaments. Validation of this model in terms of ligament length and strain was conducted by comparing it with published data on cadaver anatomy and magnetic resonance imaging. The model based on ligament lengths and strains is in concurrence with those from the published studies but is sensitive to ligament attachment positions. This ankle computational model has the potential to be used in robot-assisted therapy for real-time assessment of ligament kinematics. The results provide information regarding the quantification of kinematics associated with ankle ligaments related to the disability level and can be used for optimizing the robotic training trajectory.

  19. Biomechanical Measures During Landing and Postural Stability Predict Second Anterior Cruciate Ligament Injury After Anterior Cruciate Ligament Reconstruction and Return to Sport

    Science.gov (United States)

    Paterno, Mark V.; Schmitt, Laura C.; Ford, Kevin R.; Rauh, Mitchell J.; Myer, Gregory D.; Huang, Bin; Hewett, Timothy E.

    2016-01-01

    Background Athletes who return to sport participation after anterior cruciate ligament reconstruction (ACLR) have a higher risk of a second anterior cruciate ligament injury (either reinjury or contralateral injury) compared with non–anterior cruciate ligament–injured athletes. Hypotheses Prospective measures of neuromuscular control and postural stability after ACLR will predict relative increased risk for a second anterior cruciate ligament injury. Study Design Cohort study (prognosis); Level of evidence, 2. Methods Fifty-six athletes underwent a prospective biomechanical screening after ACLR using 3-dimensional motion analysis during a drop vertical jump maneuver and postural stability assessment before return to pivoting and cutting sports. After the initial test session, each subject was followed for 12 months for occurrence of a second anterior cruciate ligament injury. Lower extremity joint kinematics, kinetics, and postural stability were assessed and analyzed. Analysis of variance and logistic regression were used to identify predictors of a second anterior cruciate ligament injury. Results Thirteen athletes suffered a subsequent second anterior cruciate ligament injury. Transverse plane hip kinetics and frontal plane knee kinematics during landing, sagittal plane knee moments at landing, and deficits in postural stability predicted a second injury in this population (C statistic = 0.94) with excellent sensitivity (0.92) and specificity (0.88). Specific predictive parameters included an increase in total frontal plane (valgus) movement, greater asymmetry in internal knee extensor moment at initial contact, and a deficit in single-leg postural stability of the involved limb, as measured by the Biodex stability system. Hip rotation moment independently predicted second anterior cruciate ligament injury (C = 0.81) with high sensitivity (0.77) and specificity (0.81). Conclusion Altered neuromuscular control of the hip and knee during a dynamic landing task

  20. Common Types and Countermeasures of Ankle Ligament Injury ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... Objective: To analyze ankle ligament injury of basketball players caused during movement, summarize ... players with ankle ligament injury during basketball movement and admitted to different .... Road Success 2010;8:70. 5.

  1. Return to National Basketball Association Competition Following Anterior Cruciate Ligament and Fibular Collateral Ligament Injuries: A Case Report.

    Science.gov (United States)

    LaPrade, Robert F; O'Brien, Luke; Kennedy, Nicholas I; Cinque, Mark E; Chahla, Jorge

    2017-01-01

    Numerous outcome studies regarding anterior cruciate ligament (ACL) reconstruction demonstrate the ability of athletes to return to a high level of play. However, to our knowledge, there is limited literature regarding return to play following injury to both the ACL and the fibular collateral ligament (FCL). We describe the case of a National Basketball Association (NBA) player who sustained a combined ACL and FCL knee injury and subsequently underwent surgical reconstruction of both affected ligaments. He was able to return to a preinjury level of competition at 9 months postoperatively. It is possible for athletes to return to competitive basketball and maintain a high production level following a single-staged reconstruction of both the ACL and the FCL.

  2. Nõmme maja "Kergus" : Kerese tn., Tallinn / Ülar Mark, Kalle Komissarov

    Index Scriptorium Estoniae

    Mark, Ülar

    1999-01-01

    Kahekorruselise, tänavapoolse pika umbse seinaga eramu projekteeris Arhitektuuribüroo Mark & Tamm, arhitekt Ülar Mark, kaasautor Kalle Komissarov. Konstruktiivne osa: Randväli & Karema Inseneribüroo. Projekt 1997, hoone valmis 1999. Eramu tähenduse ümbermõtestamisest. 13 illustratsiooni: korruste plaanid, välisvaated, sisevaade.Mark & Tamm (arhitektibüroo)

  3. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    OpenAIRE

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance ima...

  4. Anatomic deltoid ligament repair with anchor-to-post suture reinforcement: technique tip.

    Science.gov (United States)

    Lack, William; Phisitkul, Phinit; Femino, John E

    2012-01-01

    The deltoid ligament is the primary ligamentous stabilizer of the ankle joint. Both superficial and deep components of the ligament can be disrupted with a rotational ankle fracture, chronic ankle instability, or in late stage adult acquired flatfoot deformity. The role of deltoid ligament repair in these conditions has been limited and its contribution to arthritis is largely unknown. Neglect of the deltoid ligament in the treatment of ankle injuries may be due to difficulties in diagnosis and lack of an effective method for repair. Most acute repair techniques address the superficial deltoid ligament with direct end-to-end repair, fixation through bone tunnels, or suture anchor repair of avulsion injuries. Deep deltoid ligament repair has been described using direct end-to-end repair with sutures, as well as by autograft and allograft tendon reconstruction utilizing various techniques. Newer tenodesis techniques have been described for late reconstruction of both deep and superficial components in patients with stage 4 adult acquired flatfoot deformity. We describe a technique that provides anatomic ligament-to-bone repair of the superficial and deep bundles of the deltoid ligament while reducing the talus toward the medial malleolar facet of the tibiotalar joint with anchor-to-post reinforcement of the ligamentous repair. This technique may protect and allow the horizontally oriented fibers of the deep deltoid ligament to heal with the appropriate resting length while providing immediate stability of the construct.

  5. [Ligament-controlled positioning of the knee prosthesis components].

    Science.gov (United States)

    Widmer, K-H; Zich, A

    2015-04-01

    There are at least two predominant goals in total knee replacement: first, the surgeon aims to achieve an optimal postoperative kinematic motion close to the patient's physiological range, and second, he aims for concurrent high ligament stability to establish pain-free movement for the entire range of motion. A number of prosthetic designs and surgical techniques have been developed in recent years to achieve both of these targets. This study presents another modified surgical procedure for total knee implantation. As in common practice the osteotomies are planned preoperatively, referencing well-defined bony landmarks, but their placement and orientation are also controlled intraoperatively in a stepwise sequence via ligamentous linkages. This method is open to all surgical approaches and can be applied for PCL-conserving or -sacrificing techniques. The anterior femoral osteotomy is carried out first, followed by the distal femoral osteotomy. Then, the extension gap is finalized by tensioning the ligaments and "top-down" referencing at the level of the tibial osteotomy, followed by finishing the flexion gap in the same way, except that the osteotomy of the posterior condyles is referenced in a "bottom-up" fashion. Hence, this technique relies on both bony and ligament-controlled procedures. Thus, it respects the modified ligamentous framework and drives the prosthetic components into the new ligamentous envelope. Further improvement may be achieved by additional control of the kinematics during surgery by applying modern computer navigation technology.

  6. Creep behaviour and creep mechanisms of normal and healing ligaments

    Science.gov (United States)

    Thornton, Gail Marilyn

    Patients with knee ligament injuries often undergo ligament reconstructions to restore joint stability and, potentially, abate osteoarthritis. Careful literature review suggests that in 10% to 40% of these patients the graft tissue "stretches out". Some graft elongation is likely due to creep (increased elongation of tissue under repeated or sustained load). Quantifying creep behaviour and identifying creep mechanisms in both normal and healing ligaments is important for finding clinically relevant means to prevent creep. Ligament creep was accurately predicted using a novel yet simple structural model that incorporated both collagen fibre recruitment and fibre creep. Using the inverse stress relaxation function to model fibre creep in conjunction with fibre recruitment produced a superior prediction of ligament creep than that obtained from the inverse stress relaxation function alone. This implied mechanistic role of fibre recruitment during creep was supported using a new approach to quantify crimp patterns at stresses in the toe region (increasing stiffness) and linear region (constant stiffness) of the stress-strain curve. Ligament creep was relatively insensitive to increases in stress in the toe region; however, creep strain increased significantly when tested at the linear region stress. Concomitantly, fibre recruitment was evident at the toe region stresses; however, recruitment was limited at the linear region stress. Elevating the water content of normal ligament using phosphate buffered saline increased the creep response. Therefore, both water content and fibre recruitment are important mechanistic factors involved in creep of normal ligaments. Ligament scars had inferior creep behaviour compared to normal ligaments even after 14 weeks. In addition to inferior collagen properties affecting fibre recruitment and increased water content, increased glycosaminoglycan content and flaws in scar tissue were implicated as potential mechanisms of scar creep

  7. Tissue engineering of ligaments : A comparison of bone marrow stromal cells, anterior cruciate ligament, and skin fibroblasts as cell source

    NARCIS (Netherlands)

    Van Eijk, F; Riesle, J; Willems, WJ; Van Blitterswijk, CA; Verbout, AJ; Dhert, WJA

    Anterior cruciate ligament (ACL) reconstruction surgery still has important problems to overcome, such as "donor site morbidity" and the limited choice of grafts in revision surgery. Tissue engineering of ligaments may provide a solution for these problems. Little is known about the optimal cell

  8. Subfailure injury of the rabbit anterior cruciate ligament.

    Science.gov (United States)

    Panjabi, M M; Yoldas, E; Oxland, T R; Crisco, J J

    1996-03-01

    Ligamentous injuries range in severity from a simple sprain to a complete rupture. Although sprains occur more frequently than complete failures, only a few studies have investigated the phenomena of these subfailure injuries. The purpose of our study was to document the changes in the load-deformation curve until the failure point, after the ligament has been subjected to an 80% subfailure stretch. Thirteen paired fresh rabbit bone-anterior cruciate ligament-bone preparations were used. One of the pairs (control) was stretched until failure; the other (experimental) was first stretched to 80% of the failure deformation of the control and then stretched to failure. Comparisons were made between the load-deformation curves of the experimental and control specimens. The nonlinear load-deformation curves were characterized by eight parameters: failure load (Ffail), failure deformation (Dfail), energy until failure (Efail), deformations measured at 5, 10, 25, and 50% of the failure load (D5, D10, D25, and D50, respectively), and stiffness measured at 50% of the failure force (K50). There were no significant differences in the values for Ffail, Dfail, and Efail between the experimental and control ligaments (p > 0.33). In contrast, the deformation values were all larger for the experimental than the control ligaments (p > 0.01). The deformations D5, D10, D25, and D50 (mean +/- SD) for the control were 0.36 +/- 0.13, 0.49 +/- 0.23, 0.81 +/- 0.35, and 1.23 +/- 0.41 mm. The corresponding deformations for the experimental ligaments were, respectively, 209, 186, 153, and 130% of the control values. K50 was also greater for the experimental ligament (125.0 +/- 41.7 N/mm compared with 108.7 +/- 31.4 N/mm, p < 0.03). These findings indicate that even though the strength of the ligament did not change due to a subfailure injury, the shape of the load-displacement curve, especially at low loads, was significantly altered. Under the dynamic in vivo loading conditions of daily

  9. Reconstruction of the Anterior Cruciate Ligament : Alternative Strategies

    NARCIS (Netherlands)

    van Eijk, F.

    2009-01-01

    This thesis describes the long-term results of reconstruction of the anterior cruciate ligament with an allograft. Due to the poor results found, further studies were performed to investigate alternative strategies for reconstruction of the anterior cruciate ligament in the field of tissue

  10. Advanced imaging of the scapholunate ligamentous complex

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, Maryam; Maeseneer, Michel de; Boulet, Cedric; Mey, Johan de [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Radiology, Brussels (Belgium); Staelens, Barbara; Scheerlinck, Thierry [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Orthopaedics and Traumatology, Brussels (Belgium); Overstraeten, Luc van [Hand and Foot Surgery Unit (HFSU), Tournai (Belgium)

    2015-12-15

    The scapholunate joint is one of the most involved in wrist injuries. Its stability depends on primary and secondary stabilisers forming together the scapholunate complex. This ligamentous complex is often evaluated by wrist arthroscopy. To avoid surgery as diagnostic procedure, optimization of MR imaging parameters as use of three-dimensional (3D) sequences with very thin slices and high spatial resolution, is needed to detect lesions of the intrinsic and extrinsic ligaments of the scapholunate complex. The paper reviews the literature on imaging of radial-sided carpal ligaments with advanced computed tomographic arthrography (CTA) and magnetic resonance arthrography (MRA) to evaluate the scapholunate complex. Anatomy and pathology of the ligamentous complex are described and illustrated with CTA, MRA and corresponding arthroscopy. Sprains, mid-substance tears, avulsions and fibrous infiltrations of carpal ligaments could be identified on CTA and MRA images using 3D fat-saturated PD and 3D DESS (dual echo with steady-state precession) sequences with 0.5-mm-thick slices. Imaging signs of scapholunate complex pathology include: discontinuity, nonvisualization, changes in signal intensity, contrast extravasation (MRA), contour irregularity and waviness and periligamentous infiltration by edema, granulation tissue or fibrosis. Based on this preliminary experience, we believe that 3 T MRA using 3D sequences with 0.5-mm-thick slices and multiplanar reconstructions is capable to evaluate the scapholunate complex and could help to reduce the number of diagnostic arthroscopies. (orig.)

  11. Telomere length of anterior crucial ligament after rupture

    DEFF Research Database (Denmark)

    Ponsot, Elodie; Langberg, Henning; Krogsgaard, Michael R

    2011-01-01

    The regeneration of ligaments following injury is a slow process compared to the healing of many other tissues and the underlying mechanisms remain unknown. The purpose of the study was to evaluate the proliferative potential of ligaments by assessing telomere length within three distinct parts...... of human anterior cruciate ligament (ACL) obtained during ACL reconstruction: the macroscopically injured proximal part and macroscopically noninjured mid- and distal portions in eight subjects (age 28 ± 8 years). The mean telomere length in ACL was within normal range of values usually reported for other...... tissues indicating that the endogenous machinery responsible for the proliferative potential of ligament is not implicated in its poor healing capacity. The three ACL parts showed similar mean TRF lengths (distal part: 11.5 ± 0.8 kbp, mid-portion: 11.8 ± 1.2 kbp, proximal part: 11.9 ± 1.6 kbp...

  12. A Review on Biomechanics of Anterior Cruciate Ligament and Materials for Reconstruction

    Science.gov (United States)

    Marieswaran, M.; Jain, Ishita; Garg, Bhavuk; Sharma, Vijay

    2018-01-01

    The anterior cruciate ligament is one of the six ligaments in the human knee joint that provides stability during articulations. It is relatively prone to acute and chronic injuries as compared to other ligaments. Repair and self-healing of an injured anterior cruciate ligament are time-consuming processes. For personnel resuming an active sports life, surgical repair or replacement is essential. Untreated anterior cruciate ligament tear results frequently in osteoarthritis. Therefore, understanding of the biomechanics of injury and properties of the native ligament is crucial. An abridged summary of the prominent literature with a focus on key topics on kinematics and kinetics of the knee joint and various loads acting on the anterior cruciate ligament as a function of flexion angle is presented here with an emphasis on the gaps. Briefly, we also review mechanical characterization composition and anatomy of the anterior cruciate ligament as well as graft materials used for replacement/reconstruction surgeries. The key conclusions of this review are as follows: (a) the highest shear forces on the anterior cruciate ligament occur during hyperextension/low flexion angles of the knee joint; (b) the characterization of the anterior cruciate ligament at variable strain rates is critical to model a viscoelastic behavior; however, studies on human anterior cruciate ligament on variable strain rates are yet to be reported; (c) a significant disparity on maximum stress/strain pattern of the anterior cruciate ligament was observed in the earlier works; (d) nearly all synthetic grafts have been recalled from the market; and (e) bridge-enhanced repair developed by Murray is a promising technique for anterior cruciate ligament reconstruction, currently in clinical trials. It is important to note that full extension of the knee is not feasible in the case of most animals and hence the loading pattern of human ACL is different from animal models. Many of the published reviews on

  13. Knee ligament injuries associated with long bone fractures

    Directory of Open Access Journals (Sweden)

    Kaseb M.H

    2007-06-01

    Full Text Available Background: Tibial and femoral fractures, commonly seen in emergency departments, may be associated with various knee ligament injuries. The aim of this study was to determine the prevalence of such fracture-associated knee ligament problems, with especial attention to rapid diagnosis. Methods: This study was carried out in patients with femoral or tibial fractures who were operated on in Imam Khomeini Medical Center from March 2003 to March 2005. All patients underwent surgical repair immediately after acute fracture, followed by a thorough knee examination. Patients with positive clinical findings were further evaluated using the stress view and arthroscopy. Results: We enrolled 470 cases in this study, of which 266 were tibial and 204 were femoral fractures. There were 404 men and 67 women, with an average age of tibial fracture patients was 34.5 and 44.6 years for those with femoral fractures. Of all fractures, 66% were due to car accidents, 16% to industrial accidents and 8% due to falling. The overall prevalence of ligament injuries in tibial fractures was as follows: 6.58% ACL tearing, 2.5% PCL, 21.95% MCL and 14.63% LCL. The overall prevalence of ligament injuries in femoral fractures was as follows: 6% ACL tearing, 3% PCL, 14% MCL and 8% LCL. Conclusion: The prevalence of ligament injuries of the knee was highest in distal femoral and tibial plateau fractures. It is prudent to perform a thorough knee examination once the fracture is stabilized in the operating room for the early detection of ligament injuries and prevention of further complications.

  14. Electron Attenuation Measurement using Cosmic Ray Muons at the MicroBooNE LArTPC

    Energy Technology Data Exchange (ETDEWEB)

    Meddage, Varuna [Kansas State U., Manhattan

    2017-10-01

    The MicroBooNE experiment at Fermilab uses liquid argon time projection chamber (LArTPC) technology to study neutrino interactions in argon. A fundamental requirement for LArTPCs is to achieve and maintain a low level of electronegative contaminants in the liquid to minimize the capture of drifting ionization electrons. The attenuation time for the drifting electrons should be long compared to the maximum drift time, so that the signals from particle tracks that generate ionization electrons with long drift paths can be detected efficiently. In this talk we present MicroBooNE measurement of electron attenuation using cosmic ray muons. The result yields a minimum electron 1/e lifetime of 18 ms under typical operating conditions, which is long compared to the maximum drift time of 2.3 ms.

  15. Tissue engineered devices for ligament repair, replacement and ...

    African Journals Online (AJOL)

    potential, severe damage warrants surgical intervention including complete replacement. Ligaments are longitudinally arranged, complex tissues; the mechanical properties of ligaments are a direct result of their components and the arrangement of these components in the tissue. It is these mechanics that have made ...

  16. Reconstruction of the Anterior Cruciate Ligament : Alternative Strategies

    OpenAIRE

    van Eijk, F.

    2009-01-01

    This thesis describes the long-term results of reconstruction of the anterior cruciate ligament with an allograft. Due to the poor results found, further studies were performed to investigate alternative strategies for reconstruction of the anterior cruciate ligament in the field of tissue engineering.

  17. Common types and countermeasures of ankle ligament injury ...

    African Journals Online (AJOL)

    Objective: To analyze ankle ligament injury of basketball players caused during movement, summarize injury types, analyze the causes of injury, and put forward corresponding control measures. Methods: The author selected 3100 basketball players with ankle ligament injury during basketball movement and admitted to ...

  18. Comparative transcriptional analysis of three human ligaments with distinct biomechanical properties

    Science.gov (United States)

    Lorda-Diez, Carlos I; Canga-Villegas, Ana; Cerezal, Luis; Plaza, Santiago; Hurlé, Juan M; García-Porrero, Juan A; Montero, Juan A

    2013-01-01

    One major aim of regenerative medicine targeting the musculoskeletal system is to provide complementary and/or alternative therapeutic approaches to current surgical therapies, often involving the removal and prosthetic substitution of damaged tissues such as ligaments. For these approaches to be successful, detailed information regarding the cellular and molecular composition of different musculoskeletal tissues is required. Ligaments have often been considered homogeneous tissues with common biomechanical properties. However, advances in tissue engineering research have highlighted the functional relevance of the organisational and compositional differences between ligament types, especially in those with higher risks of injury. The aim of this study was to provide information concerning the relative expression levels of a subset of key genes (including extracellular matrix components, transcription factors and growth factors) that confer functional identity to ligaments. We compared the transcriptomes of three representative human ligaments subjected to different biomechanical demands: the anterior cruciate ligament (ACL); the ligamentum teres of the hip (LT); and the iliofemoral ligament (IL). We revealed significant differences in the expression of type I collagen, elastin, fibromodulin, biglycan, transforming growth factor β1, transforming growth interacting factor 1, hypoxia-inducible factor 1-alpha and transforming growth factor β-induced gene between the IL and the other two ligaments. Thus, considerable molecular heterogeneity can exist between anatomically distinct ligaments with differing biomechanical demands. However, the LT and ACL were found to show remarkable molecular homology, suggesting common functional properties. This finding provides experimental support for the proposed role of the LT as a hip joint stabiliser in humans. PMID:24128114

  19. Calcification of the alar ligament of the cervical spine: imaging findings and clinical course

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yuka; Mochida, J.; Toh, E. [Dept. of Orthopaedic Surgery, Tokai Univ., Isehara, Kanagawa (Japan); Saito, Ikuo; Matui, Sizuka [Dept. of Orthopaedic Surgery, Odawara Hospital, Printing Bureau, Ministry of Finance, Sakawa, Odawara, Kanagawa (Japan)

    2001-05-01

    Ligamentous calcification of the cervical spine has been reported in the yellow ligament, anterior and posterior longitudinal ligaments and interspinous ligament. Calcification in the upper cervical spine is rare, although some cases with calcification of the transverse ligament of the atlas have been reported. Two patients with calcification of the alar ligament with an unusual clinical presentation and course are described. Examination by tomography and computed tomography (CT) showed calcification of the alar ligament and the transverse ligament of the atlas. CT documented decreased calcification as symptoms resolved. There may be a role for CT in the search for calcifications in the upper cervical spine in patients presenting with neck pain and pharyngodynia if radiographs are normal. (orig.)

  20. Calcification of the alar ligament of the cervical spine: imaging findings and clinical course

    International Nuclear Information System (INIS)

    Kobayashi, Yuka; Mochida, J.; Toh, E.; Saito, Ikuo; Matui, Sizuka

    2001-01-01

    Ligamentous calcification of the cervical spine has been reported in the yellow ligament, anterior and posterior longitudinal ligaments and interspinous ligament. Calcification in the upper cervical spine is rare, although some cases with calcification of the transverse ligament of the atlas have been reported. Two patients with calcification of the alar ligament with an unusual clinical presentation and course are described. Examination by tomography and computed tomography (CT) showed calcification of the alar ligament and the transverse ligament of the atlas. CT documented decreased calcification as symptoms resolved. There may be a role for CT in the search for calcifications in the upper cervical spine in patients presenting with neck pain and pharyngodynia if radiographs are normal. (orig.)

  1. Psychological Aspects of Recovery Following Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Christino, Melissa A; Fantry, Amanda J; Vopat, Bryan G

    2015-08-01

    Recovery following anterior cruciate ligament reconstruction is an arduous process that requires a significant mental and physical commitment to rehabilitation. Orthopaedic research in recent years has focused on optimizing anterior cruciate ligament surgical techniques; however, despite stable anterior cruciate ligament reconstructions, many athletes still never achieve their preinjury ability or even return to sport. Psychological factors associated with patient perceptions and functional outcomes following anterior cruciate ligament reconstruction are important to acknowledge and understand. Issues related to emotional disturbance, motivation, self-esteem, locus of control, and self-efficacy can have profound effects on patients' compliance, athletic identity, and readiness to return to sport. The psychological aspects of recovery play a critical role in functional outcomes, and a better understanding of these concepts is essential to optimize the treatment of patients undergoing anterior cruciate ligament reconstruction, particularly those who plan to return to sport. Identifying at-risk patients, encouraging a multidisciplinary approach to patient care, and providing early referral to a sports psychologist may improve patient outcomes and increase return-to-play rates among athletes. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  2. Histogramming in the LATOME-firmware for the Phase-1 upgrade of the ATLAS LAr calorimeter readout

    Energy Technology Data Exchange (ETDEWEB)

    Horn, Philipp; Hentges, Rainer; Straessner, Arno [Institut fuer Kern- und Teilchenphysik, Dresden (Germany)

    2016-07-01

    Due to the increased luminosity and the higher effective event rate after the phase 1 upgrade the ATLAS LAr detector needs new trigger electronics. The so-called LATOME-Board was designed as a LAr Digital Processing Blade (LPDB) to reconstruct the energy deposited by the particles and is an important part of the read out system. A prototype has already been build and the firmware for the on-board FPGA is under development. The insertion of a histogram-builder in this device gives the unique opportunity to look at untriggered data. This talk provides an insight in the LATOME-firmware and shows the different possibilities to implement the histogram-builder.

  3. Anterolateral Ligament (ALL — Myth or Reality?

    Directory of Open Access Journals (Sweden)

    Roman Mihai

    2017-05-01

    Full Text Available Although the anterolateral ligament (ALL was described a long time ago, recent research shows a lot of interest regarding this structure. There is a high variability concerning its anatomy, especially its capsular/extracapsular situation and insertion sites. There is also some controversy about its ligamentous structure. It seems that it has a biomechanical role in restricting anterior tibial translation and internal rotation. The ALL complex seems to have a clinical significance, and a relationship with the pivot shift has been described. Although there are promising results recently, the surgical techniques of ALL reconstruction, in addition to anterior cruciate ligament reconstruction, have to be further investigated. A precise indication algorithm and patient selection criteria need to be established.

  4. Occipital condyle fracture and ligament injury: imaging by CT

    International Nuclear Information System (INIS)

    Bloom, A.I.; Neeman, Z.; Floman, Y.; Gomori, J.; Bar-Ziv, J.

    1996-01-01

    The true incidence of fracture of the occipital condyles is unknown. It may be associated with instability at the craniocervical joint. CT is the modality of choice for the demonstration of these fractures, but its use for imaging of the associated ligament injury has not been reported. In order to demonstrate normal anatomy, occipital condyle fracture and ligament injury, and to estimate the incidence of this lesion, 21 children and young adults with high-energy blunt craniocervical injury were examined prospectively. Thin-slice, axial, contiguous, CT was performed from the base of C2 to above the foramen magnum. Bone and soft tissue windows and coronal, sagittal, and curvilinear 2D reconstructions were performed. Five occipital condyle fractures were identified in four patients (19 %), with demonstration of alar ligament injury in two cases and local hematoma in one. In four, artifacts or rotation precluded assessment of ligaments. In all remaining cases normal bone and ligament anatomy was demonstrated. Fracture of the occipital condyles following craniocervical injury is not uncommon in children and young adults. Normal bone and ligament anatomy and pathology can be safely and clearly demonstrated in seriously injured patients and others using this CT technique. Increased awareness of this entity and a low threshold for performing CT should avoid the potentially serious consequences of a missed diagnosis. (orig.). With 8 figs., 2 tabs

  5. Marker of cemento-periodontal ligament junction associated with periodontal regeneration.

    Science.gov (United States)

    Hara, Ryohko; Wato, Masahiro; Tanaka, Akio

    2005-06-01

    The purpose of this study was to identify factors promoting formation of the cemento-periodontal ligament junction. Regeneration of the cemento-periodontal ligament junction is an important factor in recovery of the connective tissue attachment to the cementum and it is important to identify all specific substances that promote its formation. To clarify the substances involved in cemento-periodontal ligament junction formation, we produced a monoclonal antibody (mAb) to human cemento-periodontal ligament junction (designated as the anti-TAP mAb) and examined its immunostaining properties and reactive antigen. Hybridomas producing monoclonal antibody against human cemento-periodontal ligament junction antigens were established by fusing P3U1 mouse myeloma cells with spleen cells from BALB/c mice immunized with homogenized human cemento-periodontal ligament junction. The mAb, the anti-TAP mAb for cemento-periodontal ligament junction, was then isolated. The immunoglobulin class and light chain of the mAb were examined using an isotyping kit. Before immunostaining, antigen determination using an enzymatic method or heating was conducted. Human teeth, hard tissue-forming lesions, and animal tissues were immunostained by the anti-TAP mAb. The anti-TAP mAb was positive in human cemento-periodontal ligament junction and predentin but negative in all other human and animal tissues examined. In the cemento-osseous lesions, the anti-TAP mAb was positive in the peripheral area of the cementum and cementum-like hard tissues and not in the bone and bone-like tissues. The anti-TAP mAb showed IgM (kappa) and recognized phosphoprotein. The anti-TAP mAb is potentially useful for developing new agents promoting cementogenesis and periodontal regeneration.

  6. Ultrasonographic assessment of the proximal digital annular ligament in the equine forelimb

    International Nuclear Information System (INIS)

    Dik, K.J.; Boroffka, S.; Stolk, P.

    1994-01-01

    Ultrasonography was used with 6 normal cadaver forelimbs of Dutch Warmblood horses to delineate the ultrasonographic anatomy of the palmar pastern region, with emphasis on the proximal digital annular ligament. Using a 5.5 MHz sector scanner, the thin proximal digital annular ligament was not visible on offset sonograms. Only if the digital sheath in the normal limb was distended was the distal border of this ligament outlined. In all normal limbs the palmarodistal thickness of the combined skin-proximal digital annular ligament layer in the mid-pastern region was 2 mm. The flexor tendons and distal sesamoidean ligaments were easily identified as hyperechoic structures. Distension of the digital sheath in the normal limbs clearly outlined the anechoic digital sheath pouches. In 4 lame horses ultrasonography aided the diagnosis of functional proximal digital annular ligament constriction. In all 4 diseased forelimbs ultrasonography demonstrated thickening of the skin-proximal digital annular ligament layer and distension of the digital sheath. In one of these limbs the distended digital sheath was also thickened. The flexor tendons and distal sesamoidean ligaments were normal. There was no radiographic evidence of additional bone or joint lesions

  7. Ultrasonographic assessment of the proximal digital annular ligament in the equine forelimb.

    Science.gov (United States)

    Dik, K J; Boroffka, S; Stolk, P

    1994-01-01

    Ultrasonography was used with 6 normal cadaver forelimbs of Dutch Warmblood horses to delineate the ultrasonographic anatomy of the palmar pastern region, with emphasis on the proximal digital annular ligament. Using a 5.5 MHz sector scanner, the thin proximal digital annular ligament was not visible on offset sonograms. Only if the digital sheath in the normal limb was distended was the distal border of this ligament outlined. In all normal limbs the palmarodistal thickness of the combined skin-proximal digital annular ligament layer in the mid-pastern region was 2 mm. The flexor tendons and distal sesamoidean ligaments were easily identified as hyperechoic structures. Distension of the digital sheath in the normal limbs clearly outlined the anechoic digital sheath pouches. In 4 lame horses ultrasonography aided the diagnosis of functional proximal digital annular ligament constriction. In all 4 diseased forelimbs ultrasonography demonstrated thickening of the skin-proximal digital annular ligament layer and distension of the digital sheath. In one of these limbs the distended digital sheath was also thickened. The flexor tendons and distal sesamoidean ligaments were normal. There was no radiographic evidence of additional bone or joint lesions.

  8. Postural stability in subjects with anterior cruciate ligament injury

    OpenAIRE

    Kolář, Miroslav

    2011-01-01

    6 Abstract Title: Postural stability in subjects with anterior cruciate ligament injury. Objectives: The aim of this thesis was to find out if the postural stability is differed in subjects with anterior cruciate ligament injury and in the control group after the "4 steps - one leg stance" test had been performed. Methods: This study compared a group with anterior cruciate ligament injury and a control group on the basis of the "4 steps - one leg stance" test. Methods of comparison and analys...

  9. Lichenised and Lichenicolous Fungi of Aladağlar National Park (Niğde, Kayseri and Adana Provinces) in Turkey

    OpenAIRE

    HALICI, Mehmet Gökhan; AKSOY, Ahmet

    2014-01-01

    Three hundred and two lichenised fungi taxa belonging to 90 genera and 45 lichenicolous fungi taxa belonging to 24 genera are reported from Aladağlar National Park. Of these, 290 lichenised fungi taxa and 21 lichenicolous fungi taxa are reported for the first time from Aladağlar National Park. Nine species of lichenised fungi, namely Arthopyrenia fraxini A.Massal., Aspicilia obscurata (Fr.) Arnold, Cephalophysis leucospila (Anzi) H.Kilias & Scheid., Chaenotheca ferruginea (Turner ex S...

  10. Craniocervical junction in dogs revisited--new ligaments and confirmed presence of enthesis fibrocartilage.

    Science.gov (United States)

    Kupczynska, M; Wieladek, A; Janczyk, P

    2012-06-01

    The study was performed to investigate and to describe features of gross and microscopic morphology of craniocervical junction (CCJ) in dogs. Seventy mature dogs (38 females, 32 males) of different body weight, representing small, medium and large breeds of dolicho-, mesati-, and brachycephalic morphotype were dissected. Morphological details were localised using an operating microscope with integrated video channel. Occurrence and distribution of fibrocartilage in the ligaments from 10 dogs was analysed histologically. Three new pairs of ligaments were described and named: dorsal ligaments of atlas, cranial internal collateral ligaments of atlas, and caudal internal collateral ligaments of atlas. Several new findings in the course of the known ligaments were found relating to breed and body weight. For the first time enthesis fibrocartilage was identified in ligaments of CCJ in dogs. Sesamoidal fibrocartilage was identified in the transversal ligament of atlas in large dogs. The findings are discussed for clinical importance. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Tissue engineered devices for ligament repair, replacement and ...

    African Journals Online (AJOL)

    PRECIOUS

    2009-12-29

    Dec 29, 2009 ... These devices use a wide variety of materials and designs to replicate ligament ... other during the application of strain, leading to viscous dissipation of stress at low ... low strains without straining the collagen molecules and plastically ..... anterior cruciate ligament: current and future concepts. New York:.

  12. Ligament-bone interaction in a three-dimensional model of the knee

    NARCIS (Netherlands)

    Blankevoort, L.; Huiskes, H.W.J.

    1991-01-01

    In mathematical knee-joint models, the ligaments are usually represented by straight-line elements, connecting the insertions of the femur and tibia. Such a model may not be valid if a ligament is bent in its course over bony surfaces, particularly not if the resulting redirection of the ligament

  13. Ligament-bone interaction in a three-dimensional model of the knee

    NARCIS (Netherlands)

    Blankevoort, L.; Huiskes, R.

    1991-01-01

    In mathematical knee-joint models, the ligaments are usually represented by straight-line elements, connecting the insertions of the femur and tibia. Such a model may not be valid if a ligament is bent in its course over bony-surfaces, particularly not if the resulting redirection of the ligament

  14. A Review on Biomechanics of Anterior Cruciate Ligament and Materials for Reconstruction

    Directory of Open Access Journals (Sweden)

    M. Marieswaran

    2018-01-01

    Full Text Available The anterior cruciate ligament is one of the six ligaments in the human knee joint that provides stability during articulations. It is relatively prone to acute and chronic injuries as compared to other ligaments. Repair and self-healing of an injured anterior cruciate ligament are time-consuming processes. For personnel resuming an active sports life, surgical repair or replacement is essential. Untreated anterior cruciate ligament tear results frequently in osteoarthritis. Therefore, understanding of the biomechanics of injury and properties of the native ligament is crucial. An abridged summary of the prominent literature with a focus on key topics on kinematics and kinetics of the knee joint and various loads acting on the anterior cruciate ligament as a function of flexion angle is presented here with an emphasis on the gaps. Briefly, we also review mechanical characterization composition and anatomy of the anterior cruciate ligament as well as graft materials used for replacement/reconstruction surgeries. The key conclusions of this review are as follows: (a the highest shear forces on the anterior cruciate ligament occur during hyperextension/low flexion angles of the knee joint; (b the characterization of the anterior cruciate ligament at variable strain rates is critical to model a viscoelastic behavior; however, studies on human anterior cruciate ligament on variable strain rates are yet to be reported; (c a significant disparity on maximum stress/strain pattern of the anterior cruciate ligament was observed in the earlier works; (d nearly all synthetic grafts have been recalled from the market; and (e bridge-enhanced repair developed by Murray is a promising technique for anterior cruciate ligament reconstruction, currently in clinical trials. It is important to note that full extension of the knee is not feasible in the case of most animals and hence the loading pattern of human ACL is different from animal models. Many of the

  15. Injuries of the lateral collateral ligaments of the ankle: assessment with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F.; Ferber, A.; Grebe, P.; Thelen, M. [Department of Radiology, Johannes Gutenberg University Mainz (Germany); Runkel, M. [Department of Traumatologic and Reconstructive Surgery, Johannes Gutenberg University Mainz (Germany); Berger, S. [Department of Pediatric Surgery, Johannes Gutenberg University Mainz (Germany)

    1999-04-01

    The aim of this study was to evaluate the ability of MRI to display injuries of the lateral collateral ligamentous complex in patients with an acute ankle distorsion trauma. The MR examinations of 36 patients with ankle pain after ankle distorsion were evaluated retrospectively without knowledge of clinical history, outcome and/or operative findings. The examinations were performed on a 1.5-T whole-body imager using a flexible surface coil. The signs for ligamentous abnormality were as follows: complete or partial discontinuity, increased signal within, and irregularity and waviness of the ligament. The results were compared with operative findings in 18 patients with subsequent surgical repair. Eighteen patients with conservative therapy had a follow-up MR examination after 3 months. There was 1 sprain, 3 partial and 32 complete tears of the anterior talofibular ligament, and 5 sprains, 5 partial, and 7 complete tears of the calcaneofibular ligament. There were no lesions of the posterior talofibular ligament. Compared with surgery, MRI demonstrated in 18 of 18 cases the exact extent of anterior talofibular ligament injuries and underestimated the extent in 2 of 8 cases of calcaneofibular ligament injury. In patients with follow-up MRI after conservative therapy, a thickened band-like structure was found along the course of the injured ligament in 17 of 18 cases. The absence of ligament repair after conservative treatment was confirmed during operative revision in one case. The MRI technique allows for grading of the extent of injury of the lateral collateral ligamentous complex after acute ankle strain. It seems to be suitable for monitoring the healing process after conservative-functional treatment of ligament tears. (orig.) With 5 figs., 2 tabs., 26 refs.

  16. Injuries of the lateral collateral ligaments of the ankle: assessment with MR imaging

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ferber, A.; Grebe, P.; Thelen, M.; Runkel, M.; Berger, S.

    1999-01-01

    The aim of this study was to evaluate the ability of MRI to display injuries of the lateral collateral ligamentous complex in patients with an acute ankle distorsion trauma. The MR examinations of 36 patients with ankle pain after ankle distorsion were evaluated retrospectively without knowledge of clinical history, outcome and/or operative findings. The examinations were performed on a 1.5-T whole-body imager using a flexible surface coil. The signs for ligamentous abnormality were as follows: complete or partial discontinuity, increased signal within, and irregularity and waviness of the ligament. The results were compared with operative findings in 18 patients with subsequent surgical repair. Eighteen patients with conservative therapy had a follow-up MR examination after 3 months. There was 1 sprain, 3 partial and 32 complete tears of the anterior talofibular ligament, and 5 sprains, 5 partial, and 7 complete tears of the calcaneofibular ligament. There were no lesions of the posterior talofibular ligament. Compared with surgery, MRI demonstrated in 18 of 18 cases the exact extent of anterior talofibular ligament injuries and underestimated the extent in 2 of 8 cases of calcaneofibular ligament injury. In patients with follow-up MRI after conservative therapy, a thickened band-like structure was found along the course of the injured ligament in 17 of 18 cases. The absence of ligament repair after conservative treatment was confirmed during operative revision in one case. The MRI technique allows for grading of the extent of injury of the lateral collateral ligamentous complex after acute ankle strain. It seems to be suitable for monitoring the healing process after conservative-functional treatment of ligament tears. (orig.)

  17. MR imaging of normal extrinsic wrist ligaments using thin slices with clinical and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M., E-mail: maryam.shahabpour@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); De Maeseneer, M., E-mail: michel.demaeseneer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Pouders, C. [Department of Experimental Anatomy, Vrije Universiteit Brussel (Belgium); Van Overstraeten, L. [Department of Foot and Hand Surgery, Centre Hospitalier Regional de Wallonie Picarde, Tournai (Belgium); Ceuterick, P. [Department of Hand Surgery, Europa Ziekenhuizen, Brussels (Belgium); Fierens, Y. [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Goubau, J. [Department of Orthopaedic Surgery, UZ Brussel, Brussels (Belgium); De Mey, J. [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium)

    2011-02-15

    Eighty-nine MR examinations of the wrist were retrospectively analyzed. MRI results were compared with clinical findings and/or arthroscopy. Thin proton density and T2 weighted sequences and 3D DESS weighted sequences were applied on a 1.5 T scanner. On the palmar side three radiocarpal ligaments are recognized including the radioscaphocapitate, radiolunotriquetral, radioscapholunate, and midcarpal triquetroscaphoidal ligaments. Ulnocarpal ligaments include the ulnolunate ligament and the ulnotriquetral ligament. On the dorsal side three ligaments are recognized: the dorsal radiolunotriquetral, and the midcarpal triquetroscaphoidal and triquetro-trapezoido-trapezial. The collateral ligaments include the radial and ulnar collateral ligament. MR is a valuable technique in the assessment of the extrinsic and midcarpal ligaments. Depiction of the extrinsic ligaments can best be accomplished with coronal 3D DESS sequences and sagittal and transverse proton density and T2 weighted sequences with thin slices.

  18. Anterior cruciate ligament repair - past, present and future.

    Science.gov (United States)

    Mahapatra, Piyush; Horriat, Saman; Anand, Bobby S

    2018-06-15

    This article provides a detailed narrative review on the history and current concepts surrounding ligamentous repair techniques in athletic patients. In particular, we will focus on the anterior cruciate ligament (ACL) as a case study in ligament injury and ligamentous repair techniques. PubMed (MEDLINE), EMBASE and Cochrane Library databases for papers relating to primary anterior cruciate ligament reconstruction were searched by all participating authors. All relevant historical papers were included for analysis. Additional searches of the same databases were made for papers relating to biological enhancement of ligament healing. The poor capacity of the ACL to heal is one of the main reasons why the current gold standard surgical treatment for an ACL injury in an athletic patient is ACL reconstruction with autograft from either the hamstrings or patella tendon. It is hypothesised that by preserving and repairing native tissues and negating the need for autograft that primary ACL repair may represent a key step change in the treatment of ACL injuries. The history of primary ACL repair will be discussed and the circumstances that led to the near-abandonment of primary ACL repair techniques will be reviewed. There has been a recent resurgence in interest with regards to primary ACL repair. Improvements in imaging now allow for identification of tear location, with femoral-sided injuries, being more suitable for repair. We will discuss in details strategies for improving the mechanical and biological environment in order to allow primary healing to occur. In particular, we will explain mechanical supplementation such as Internal Brace Ligament Augmentation and Dynamic Intraligamentary Stabilisation techniques. These are novel techniques that aim to protect the primary repair by providing a stabilising construct that connects the femur and the tibia, thus bridging the repair. In addition, biological supplementation is being investigated as an adjunct and we will

  19. High-Fat Diet Augments VPAC1 Receptor-Mediated PACAP Action on the Liver, Inducing LAR Expression and Insulin Resistance

    Directory of Open Access Journals (Sweden)

    Masanori Nakata

    2016-01-01

    Full Text Available Pituitary adenylate cyclase-activating polypeptide (PACAP acts on multiple processes of glucose and energy metabolism. PACAP potentiates insulin action in adipocytes and insulin release from pancreatic β-cells, thereby enhancing glucose tolerance. Contrary to these effects at organ levels, PACAP null mice exhibit hypersensitivity to insulin. However, this apparent discrepancy remains to be solved. We aimed to clarify the mechanism underlying the antidiabetic phenotype of PACAP null mice. Feeding with high-fat diet (HFD impaired insulin sensitivity and glucose tolerance in wild type mice, whereas these changes were prevented in PACAP null mice. HFD also impaired insulin-induced Akt phosphorylation in the liver in wild type mice, but not in PACAP null mice. Using GeneFishing method, HFD increased the leukocyte common antigen-related (LAR protein tyrosine phosphatase in the liver in wild type mice. Silencing of LAR restored the insulin signaling in the liver of HFD mice. Moreover, the increased LAR expression by HFD was prevented in PACAP null mice. HFD increased the expression of VPAC1 receptor (VPAC1-R, one of three PACAP receptors, in the liver of wild type mice. These data indicate that PACAP-VPAC1-R signaling induces LAR expression and insulin resistance in the liver of HFD mice. Antagonism of VPAC1-R may prevent progression of HFD-induced insulin resistance in the liver, providing a novel antidiabetic strategy.

  20. Uneventful octreotide LAR therapy throughout three pregnancies, with favorable delivery and anthropometric measures for each newborn: a case report

    Directory of Open Access Journals (Sweden)

    Naccache Deeb

    2011-08-01

    Full Text Available Abstract Introduction The safety of octreotide use, in its short-acting preparation, in pregnancy is still unclear. This report provides the first documentation of uneventful octreotide LAR use during three pregnancies in a woman with bronchial carcinoid-associated adrenocorticotropic hormone-dependent Cushing's syndrome. Case presentation A 25-year-old Arabic woman presented to our emergency department with rapid onset of headache, flaring acne and hirsutism, facial puffiness, weight gain and paroxysmal myopathy, and paranoiac thoughts of rape and sexual intimidation. After undergoing surgical removal of a mass by left lower lung lobectomy, her residual lung disease medical therapy failed. Chronic octreotide LAR injections were initiated as indicated by a positive octreoscan. Follow-up revealed a long-lasting positive response to octreotide. Avidity of octreotide to somatostatin receptor sub-type 2 was later confirmed by a positive somatostatin receptor sub-type 2 in the resected tumor specimen. Against our instructions, the patient had three spontaneous pregnancies leading to delivery of three full-term healthy children while her octreotide LAR therapy continued. Conclusion This case adds more data supporting the potential for the safe use of octreotide and the feasibility of octreotide LAR use during pregnancy, making compliance with the patient's preference not to withdraw octreotide therapy as soon as her pregnancy is confirmed a thoughtful option.

  1. MR imaging of posterior cruciate ligament injuries

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Nobuyuki [Tsukuba Univ., Ibaraki (Japan). Hospital; Niitsu, Mamoru; Itai, Yuji; Sato, Motohiro; Kujiraoka, Yuka; Ikeda, Kotaro; Kanamori, Akihiro

    2001-07-01

    Posterior cruciate ligament (PCL) injuries are less frequent than anterior cruciate ligament (ACL) injuries, but are presumably more common than once thought. Thirty-nine patients with PCL injuries identified on MR images were studied. The criteria for PCL injury were complete tear, partial tear, and avulsion fracture. The approximate site of a partial tear was categorized as proximal, midsubstance, distal, or combination. Fourteen patients (35.9%) had complete tears of the PCL, 21 patients (53.8%) had partial tears, and four patients (10.3%) had avulsion fractures. A total of 12 patients (30.7%) had isolated PCL injuries, while the remaining 27 patients demonstrated evidence of other coexistent knee injuries, such as meniscal tears and ligamentous injuries. Of coexistent knee injuries, meniscal tears (18 patients, 46.2%) were most often seen. (author)

  2. MR imaging of posterior cruciate ligament injuries

    International Nuclear Information System (INIS)

    Takahashi, Nobuyuki; Niitsu, Mamoru; Itai, Yuji; Sato, Motohiro; Kujiraoka, Yuka; Ikeda, Kotaro; Kanamori, Akihiro

    2001-01-01

    Posterior cruciate ligament (PCL) injuries are less frequent than anterior cruciate ligament (ACL) injuries, but are presumably more common than once thought. Thirty-nine patients with PCL injuries identified on MR images were studied. The criteria for PCL injury were complete tear, partial tear, and avulsion fracture. The approximate site of a partial tear was categorized as proximal, midsubstance, distal, or combination. Fourteen patients (35.9%) had complete tears of the PCL, 21 patients (53.8%) had partial tears, and four patients (10.3%) had avulsion fractures. A total of 12 patients (30.7%) had isolated PCL injuries, while the remaining 27 patients demonstrated evidence of other coexistent knee injuries, such as meniscal tears and ligamentous injuries. Of coexistent knee injuries, meniscal tears (18 patients, 46.2%) were most often seen. (author)

  3. A CULPA É DA MULHER: O Anticristo, de Lars von Trier

    Directory of Open Access Journals (Sweden)

    João Nunes Silva

    2016-08-01

    Full Text Available RESUMO O Anticristo, filme de Lars von Trier, lançado em 2009, mostra o desespero de um casal ao perder seu único filho. Extremamente polêmico e repleto de referências bíblicas - a começar pelo título -, é um filme que choca pelo incessante desespero de uma mãe em luto que parece carregar o peso do mundo em sua condição de mulher. A proposta deste artigo é fazer uma análise deste filme iluminando a culpa cristã historicamente atribuída à mulher e seus desdobramentos imediatos, como o feminicídio.   PALAVRAS-CHAVE: Análise Fílmica; Cristianismo; Feminicídio; O Anticristo.   ABSTRACT Antichrist, film of Lars von Trier, released on 2009, shows the the despair of a couple to lose their only son. Extremely controversial and fraught with biblical references - beginning with the title -, it’s a film that shocked the unyielding despair a bereaved mother that seems to carry the weight of the world on his wife's condition. The purpose of this paper is to analyze of this film illuminating the christian guilt historically attributed to the woman and their immediate consequences, like the feminicide.   KEYWORDS: Filmic Analysis; Christianity; Feminicide; Antichrist.     RESUMEN Anticristo, pelicula de Lars von Trier, lanzada em 2009, muestra el desespero de una pareja cuando pierde su único hijo. Extremadamente polémica y llena de referencias bíblicas - empezando con el título -, es una película que sorprende al inquebrantable desesperación de una madre em luto que parece cargar el peso del mundo por ser mujer. El objetivo de este artículo es analizar esta película iluminando la culpa cristiana históricamente asignada a las mujeres y sus consecuencias inmediatas, como el feminicidio.   PALABRAS CLAVE: Análisis fílmica; Cristianismo; Feminicidio; Anticristo.

  4. Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap

    Science.gov (United States)

    Cancelo, G.; Cavanna, F.; Escobar, C. O.; Kemp, E.; Machado, A. A.; Para, A.; Segreto, E.; Totani, D.; Warner, D.

    2018-03-01

    The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. In this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.

  5. R&D Studies of the ATLAS LAr Calorimeter Readout Electronics for super-LHC

    CERN Document Server

    Chen, H

    2010-01-01

    The ATLAS Liquid Argon (LAr) calorimeters are high precision, high sensitivity and high granularity detectors, total about 180,000 signals are digitized and processed real-time on detector, to provide energy and time deposited in each detector element at every occurrence of the L1-trigger. A luminosity upgrade (x10) of the LHC will occur ~2017, the current readout electronics will have to be upgraded to sustain the higher radiation levels. A completely innovative readout scheme is being developed. The front-end readout will send out data continuously at each bunch crossing through high speed radiation resistant optical links, the data will be processed real-time with the possibility of implementing trigger algorithms. This article is an overview of the R&D activities and architectural studies the ATLAS LAr collaboration is developing: front-end analog and mixed-signal ASIC design, radiation resistance optical-links in SOS, high-speed back-end processing units based on FPGA architectures and power supply d...

  6. Specialisation of extracellular matrix for function in tendons and ligaments

    Science.gov (United States)

    Birch, Helen L.; Thorpe, Chavaunne T.; Rumian, Adam P.

    2013-01-01

    Summary Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures. PMID:23885341

  7. Ex Vivo Growth of Bioengineered Ligaments and Other Tissues

    Science.gov (United States)

    Altman, Gregory; Kaplan, David L.; Martin, Ivan; Vunjak-Novakovic, Gordana

    2005-01-01

    A method of growing bioengineered tissues for use in surgical replacement of damaged anterior cruciate ligaments has been invented. An anterior cruciate ligament is one of two ligaments (the other being the posterior cruciate ligament) that cross in the middle of a knee joint and act to prevent the bones in the knee from sliding forward and backward relative to each other. Anterior cruciate ligaments are frequently torn in sports injuries and traffic accidents, resulting in pain and severe limitations on mobility. By making it possible to grow replacement anterior cruciate ligaments that structurally and functionally resemble natural ones more closely than do totally synthetic replacements, the method could create new opportunities for full or nearly full restoration of functionality in injured knees. The method is also adaptable to the growth of bioengineered replacements for other ligaments (e.g., other knee ligaments as well as those in the hands, wrists, and elbows) and to the production of tissues other than ligaments, including cartilage, bones, muscles, and blood vessels. The method is based on the finding that the histomorphological properties of a bioengineered tissue grown in vitro from pluripotent cells within a matrix are affected by the direct application of mechanical force to the matrix during growth generation. This finding provides important new insights into the relationships among mechanical stress, biochemical and cell-immobilization methods, and cell differentiation, and is applicable to the production of the variety of tissues mentioned above. Moreover, this finding can be generalized to nonmechanical (e.g., chemical and electromagnetic) stimuli that are experienced in vivo by tissues of interest and, hence, the method can be modified to incorporate such stimuli in the ex vivo growth of replacements for the various tissues mentioned above. In this method, a three-dimensional matrix made of a suitable material is seeded with pluripotent stem

  8. Fluid Flow Patterns During Production from Gas Hydrates in the Laboratory compared to Field Settings: LARS vs. Mallik

    Science.gov (United States)

    Strauch, B.; Heeschen, K. U.; Priegnitz, M.; Abendroth, S.; Spangenberg, E.; Thaler, J.; Schicks, J. M.

    2015-12-01

    The GFZ's LArge Reservoir Simulator LARS allows for the simulation of the 2008 Mallik gas hydrate production test and the comparison of fluid flow patterns and their driving forces. Do we see the gas flow pattern described for Mallik [Uddin, M. et al., J. Can. Petrol Tech, 50, 70-89, 2011] in a pilot scale test? If so, what are the driving forces? LARS has a network of temperature sensors and an electric resistivity tomography (ERT) enabling a good spatial resolution of gas hydrate occurrences, water and gas distribution, and changes in temperature in the sample. A gas flow meter and a water trap record fluid flow patterns and a backpressure valve has controlled the depressurization equivalent to the three pressure stages (7.0 - 5.0 - 4.2 MPa) applied in the Mallik field test. The environmental temperature (284 K) and confining pressure (13 MPa) have been constant. The depressurization induced immediate endothermic gas hydrate dissociation until re-establishment of the stability conditions by a consequent temperature decrease. Slight gas hydrate dissociation continued at the top and upper lateral border due to the constant heat input from the environment. Here transport pathways were short and permeability higher due to lower gas hydrate saturation. At pressures of 7.0 and 5.0 MPa the LARS tests showed high water flow rates and short irregular spikes of gas production. The gas flow patterns at 4.2 MPa and 3.0MPa resembled those of the Mallik test. In LARS the initial gas surges overlap with times of hydrate instability while water content and lengths of pathways had increased. Water production was at a minimum. A rapidly formed continuous gas phase caused the initial gas surges and only after gas hydrate dissociation decreased to a minimum the single gas bubbles get trapped before slowly coalescing again. In LARS, where pathways were short and no additional water was added, a transport of microbubbles is unlikely to cause a gas surge as suggested for Mallik.

  9. Estrogen inhibits lysyl oxidase and decreases mechanical function in engineered ligaments.

    Science.gov (United States)

    Lee, Cassandra A; Lee-Barthel, Ann; Marquino, Louise; Sandoval, Natalie; Marcotte, George R; Baar, Keith

    2015-05-15

    Women are more likely to suffer an anterior cruciate ligament (ACL) rupture than men, and the incidence of ACL rupture in women rises with increasing estrogen levels. We used an engineered ligament model to determine how an acute rise in estrogen decreases the mechanical properties of ligaments. Using fibroblasts isolated from human ACLs from male or female donors, we engineered ligaments and determined that ligaments made from female ACL cells had more collagen and were equal in strength to those made from male ACL cells. We then treated engineered ligaments for 14 days with low (5 pg/ml), medium (50 pg/ml), or high (500 pg/ml) estrogen, corresponding to the range of in vivo serum estrogen concentrations and found that collagen within the grafts increased without a commensurate increase in mechanical strength. Mimicking the menstrual cycle, with 12 days of low estrogen followed by 2 days of physiologically high estrogen, resulted in a decrease in engineered ligament mechanical function with no change in the amount of collagen in the graft. The decrease in mechanical stiffness corresponded with a 61.7 and 76.9% decrease in the activity of collagen cross-linker lysyl oxidase with 24 and 48 h of high estrogen, respectively. Similarly, grafts treated with the lysyl oxidase inhibitor β-aminoproprionitrile (BAPN) for 24 h showed a significant decrease in ligament mechanical strength [control (CON) = 1.58 ± 0.06 N; BAPN = 1.06 ± 0.13 N] and stiffness (CON = 7.7 ± 0.46 MPa; BAPN = 6.1 ± 0.71 MPa) without changing overall collagen levels (CON = 396 ± 11.5 μg; BAPN = 382 ± 11.6 μg). Together, these data suggest that the rise in estrogen during the follicular phase decreases lysyl oxidase activity in our engineered ligament model and if this occurs in vivo may decrease the stiffness of ligaments and contribute to the elevated rate of ACL rupture in women. Copyright © 2015 the American Physiological Society.

  10. STUDY OF ANTERIOR CRUCIATE LIGAMENT INJURY AND ITS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Tummala Venkata

    2016-03-01

    Full Text Available BACKGROUND The anterior cruciate ligament is the weaker of the two cruciate ligaments stabilizing the knee joint, and therefore gets torn easier than the posterior cruciate ligament. OBJECTIVE To determine pattern of anterior cruciate ligament injury and its management in a tertiary care center. MATERIALS AND METHODS A prospective study was carried out for two years, 28 patients with ACL injury were included. A detailed history regarding the pattern of injury was noted and ACL reconstruction was done using BT Bautograft with mini-arthrotomy and arthroscopic assisted ACL reconstruction. RESULTS The mean age of the study subjects was 30.6±7.3 years & majority were males. Majority of the ACL injury was sports related & was on the right knee. 64% underwent arthroscopic assisted ACL reconstruction & majority of them had normal range of motion of the knee. CONCLUSION Our present study concludes that most common age group involved was 20-30 years & ACL injury was more common among males. Patients with an early ACL reconstruction were more satisfied with the end result. Also, ACL reconstruction techniques using BTB auto graft leads to good ligamentous stability and function of the knee.

  11. Wrist ligament injuries: value of post-arthrography computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Theumann, N.; Schnyder, P.; Meuli, R. [Dept. of Diagnostic and Interventional Radiology, University Hospital, CHUV, Lausanne (Switzerland); Favarger, N. [Clinique Longeraie, Lausanne (Switzerland)

    2001-02-01

    Objective: To evaluate the use of post-arthrography high-resolution computed tomography in wrist ligament injuries.Design and patients: Thirty-six consecutive patients who had a history and clinical findings suggestive of ligamentous injuries of the wrist were prospectively studied. The findings of three-compartment arthrography and post-arthrography computed tomography (arthro-CT) were compared with those of arthroscopy. The evaluation concentrates on the detection and precise localization of ligament lesions in the triangular fibrocartilage (TFC), the scapholunate ligament (SLL) and the lunotriquetral ligament (LTL).Results: For TFC, SLL and LTL lesions, standard arthrography responded with a sensitivity and specificity of 85% and 100%, 85% and 100%, 80% and 100% respectively, while arthro-CT showed a sensitivity and specificity of 85% and 100%, 100% and 100%, 80% and 100% respectively. The precise localization of the lesions was possible only with arthro-CT.Conclusion: The sensitivity and specificity of standard arthrography and arthro-CT are similar, although the latter shows the site of tears or perforation with greater precision, while conventional arthrography demonstrates them indirectly. This precision is essential and may have clinical implications for the success of treatment procedures. (orig.)

  12. Rigid immobilization alters matrix organization in the injured rat medial collateral ligament.

    Science.gov (United States)

    Padgett, L R; Dahners, L E

    1992-11-01

    The effects of mobilization on matrix reorganization and density after ligament injury were studied in rat medial collateral ligaments using scanning electron microscopy (SEM). Both medial collateral ligaments of 14 Sprague-Dawley rats were sharply incised transversely at their midpoint. A 1.14-mm threaded Kirschner wire was driven through the tibia and into the femur of the right leg (through the knee) to immobilize that knee at 90 degrees of flexion. Four additional rats were used as controls. The right medial collateral ligament of the control rats was exposed in the same manner as the experimental rats and the wound closed without damaging the ligament. Rats were sacrificed on the 7th and 14th days postinjury and the ligaments evaluated by SEM. The electron micrographs from this study demonstrated that early on, the tissue at the injury site is disorganized on a gross scale with large bundles of poorly organized matrix. Large "defects" were present between bundles in the substance of the ligament and appeared as holes in the ligament around the injury site. As healing progressed, the matrix in the mobilized specimens appeared to bridge the injury site more rapidly and completely with fewer "defects" and thus higher density than the immobilized specimens.

  13. A space vehicle rotating with a uniform angu- lar velocity about a ...

    Indian Academy of Sciences (India)

    IAS Admin

    A space vehicle rotating with a uniform angu- lar velocity about a vertical axis fixed to it is falling freely vertically downwards, say, with its engine shut off. It carries two astronauts inside it. One astronaut throws a tiny tool towards the other astronaut. The motion of the tiny tool with reference to a rotating frame rigidly fixed.

  14. Combined medial and lateral anatomic ligament reconstruction for chronic rotational instability of the ankle.

    Science.gov (United States)

    Buchhorn, Tomas; Sabeti-Aschraf, Manuel; Dlaska, Constantin E; Wenzel, Florian; Graf, Alexandra; Ziai, Pejman

    2011-12-01

    This study aimed to extend knowledge on the arthroscopic evaluation of the unstable ankle joint and the outcome of ligament reconstruction on rotational instability. In contrast to previous studies, we investigated the combined repair of lateral and medial ligaments. Ninety-six patients underwent medial and lateral ligament reconstruction between 2006 and 2008, 81 of whom, with a mean age of 31.9 (range, 14 to 44) years, completed the 12-month followup and were therefore included in this study (Table 1). Clinical, radiographic, and concomitant arthroscopic examination was performed prior to the ligament stabilization. Postoperative followup included clinical and radiographic evaluation after 3, 6, and 12 months. Arthroscopy showed a lesion of the anterior fibulotalar ligament (AFTL), calcaneofibular ligament (CFL), and tibiocalcanear ligament (TCL) (Deep part of deltoid ligament complex) in 67 patients. An avulsion of the proximal insertion point of the ATTL was additionally found in 14 cases. Clinical results 3 months after surgery showed a significant increase in the AOFAS-Hindfoot Score as well as a significant decrease of the Visual Analogue-Scale for pain (VAS) (p ankle joint in most cases has an injury of the lateral ligaments and a component of the deltoid, the TCL, but rarely with a combined lesion of the TCL and the anterior tibiotalar ligament (ATTL) (Superficial part of deltoid ligament complex). The combined lateral and medial ligament reconstruction with an anchor technique had a good clinical outcome with high patient satisfaction with few complications.

  15. Strengthening exercises for old cruciate ligament tears.

    Science.gov (United States)

    Tegner, Y; Lysholm, J; Lysholm, M; Gillquist, J

    1986-04-01

    Fifty-three consecutive patients with troublesome old cruciate ligament lesions underwent a 3-month thigh and calf muscle training program. Before training, the diagnosis was established by arthroscopy and clinical examination under anesthesia. Significant improvement in strength, performance, knee score, and activity level took place; the majority were improved and declined surgery. A period of strength training is recommended before the decision to undertake surgery for cruciate ligament injury.

  16. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok; Kwon, Soon-Sun

    2013-01-01

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  17. Aetiology and pathogenesis of cranial cruciate ligament rupture in cats by histological examination.

    Science.gov (United States)

    Wessely, Marlis; Reese, Sven; Schnabl-Feichter, Eva

    2017-06-01

    Objectives The aim of this study was to examine histologically intact and ruptured cranial cruciate ligaments in cats, in order to evaluate whether degeneration is a prerequisite for rupture. Methods We performed a histological examination of 50 intact and 19 ruptured cranial cruciate ligaments in cadaver or client-owned cats, respectively, using light microscopy. Cats with stifle pathology were further divided into five age groups in order to investigate the relationship of changes in the ligament with lifespan. Cats with ruptured cranial cruciate ligaments were divided into two groups according to medical history (with presumed history of trauma or without any known history of trauma) in order to investigate the relationship of ligament rupture with a traumatic event. Data from 200 healthy cats were selected randomly and reviewed to make a statistical comparison of cats with and without cranial cruciate ligament rupture (reference group). Results On histological examination, the intact cranial cruciate ligaments showed basic parallel arrangement of the collagen fibres, with no relation to age. While cats of a more advanced age showed fibrocartilage in the middle of the cranial cruciate ligament - a likely physiological reaction to compression forces over the lifespan - degenerative changes within the fibrocartilage were absent in all cases, regardless of age or rupture status. Cats suffering from cranial cruciate ligament rupture without history of trauma were significantly older than cats in the reference group. Conclusions and relevance This study showed that differentiation of fibrocartilage in the middle of the cranial cruciate ligament is likely a physiological reaction to compressive forces and not a degenerative change associated with greater risk of rupture in advanced age. This finding in cats is distinct from the known decrease in differentiation of fibrocartilage in dogs with cranial cruciate ligament rupture. Furthermore, the histological examination

  18. Research and Development for a Free-Running Readout System for the ATLAS LAr Calorimeters at the High Luminosity LHC

    CERN Document Server

    AUTHOR|(SzGeCERN)758889; The ATLAS collaboration

    2016-01-01

    The ATLAS Liquid Argon (LAr) Calorimeters were designed and built to measure electromagnetic and hadronic energy in proton-proton collisions produced at the Large Hadron Collider (LHC) at centre-of-mass energies up to \\SI{14}{\\tera\\electronvolt} and instantaneous luminosities up to \\SI{d34}{\\per\\centi\\meter\\squared\\per\\second}. The High Luminosity LHC (HL-LHC) programme is now developed for up to 5-7 times the design luminosity, with the goal of accumulating an integrated luminosity of \\SI{3000}{\\per\\femto\\barn}. In the HL-LHC phase, the increased radiation levels require a replacement of the front-end (FE) electronics of the LAr Calorimeters. Furthermore, the ATLAS trigger system is foreseen to increase the trigger accept rate and the trigger latency which requires a larger data volume to be buffered. Therefore, the LAr Calorimeter read-out will be exchanged with a new FE and a high bandwidth back-end (BE) system for receiving data from all \

  19. Effects of mechanical strain on human mesenchymal stem cells and ligament fibroblasts in a textured poly(L-lactide) scaffold for ligament tissue engineering.

    Science.gov (United States)

    Kreja, Ludwika; Liedert, Astrid; Schlenker, Heiter; Brenner, Rolf E; Fiedler, Jörg; Friemert, Benedikt; Dürselen, Lutz; Ignatius, Anita

    2012-10-01

    The purpose of this study was to prove the effect of cyclic uniaxial intermittent strain on the mRNA expression of ligament-specific marker genes in human mesenchymal stem cells (MSC) and anterior cruciate ligament-derived fibroblasts (ACL-fibroblasts) seeded onto a novel textured poly(L-lactide) scaffold (PLA scaffold). Cell-seeded scaffolds were mechanically stimulated by cyclic uniaxial stretching. The expression of ligament matrix gene markers: collagen types I and III, fibronectin, tenascin C and decorin, as well as the proteolytic enzymes matrix metalloproteinase MMP-1 and MMP-2 and their tissue specific inhibitors TIMP-1 and TIMP-2 was investigated by analysing the mRNA expression using reverse transcriptase polymerase chain reaction and related to the static control. In ACL-fibroblasts seeded on PLA, mechanical load induced up-regulation of collagen types I and III, fibronectin and tenascin C. No effect of mechanical stimulation on the expression of ligament marker genes was found in undifferentiated MSC seeded on PLA. The results indicated that the new textured PLA scaffold could transfer the mechanical load to the ACL-fibroblasts and improved their ligament phenotype. This scaffold might be suitable as a cell-carrying component of ACL prostheses.

  20. Role of periodontal ligament fibroblasts in osteoclastogenesis: a review

    NARCIS (Netherlands)

    Sokos, D.; Everts, V.; de Vries, T.J.

    2015-01-01

    During the last decade it has become clear that periodontal ligament fibroblasts may contribute to the in vitro differentiation of osteoclasts. We surveyed the current findings regarding their osteoclastogenesis potential. Periodontal ligament fibroblasts have the capacity to select and attract

  1. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Energy Technology Data Exchange (ETDEWEB)

    Aalseth, C.E.; et al.

    2017-07-25

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\\gt3\\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $\

  2. Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN

    CERN Document Server

    Antonello, A.; Baibussinov, B.; Bilokon, H.; Boffelli, F.; Bonesini, M.; Calligarich, E.; Canci, N.; Centro, S.; Cesana, A.; Cieslik, K.; Cline, D.B.; Cocco, A.G.; Dequal, D.; Dermenev, A.; Dolfini, R.; De Gerone, M.; Dussoni, S.; Farnese, C.; Fava, A.; Ferrari, A.; Fiorillo, G.; Garvey, G.T.; Gatti, F.; Gibin, D.; Gninenko, S.; Guber, F.; Guglielmi, A.; Haranczyk, M.; Holeczek, J.; Ivashkin, A.; Kirsanov, M.; Kisiel, J.; Kochanek, I.; Kurepin, A.; Lagoda, J.; Lucchini, G.; Louis, W.C.; Mania, S.; Mannocchi, G.; Marchini, S.; Matveev, V.; Menegolli, A.; Meng, G.; Mills, G.B.; Montanari, C.; Nicoletto, M.; Otwinowski, S.; Palczewki, T.J.; Passardi, G.; Perfetto, F.; Picchi, P.; Pietropaolo, F.; Plonski, P.; Rappoldi, A.; Raselli, G.L.; Rossella, M.; Rubbia, C.; Sala, P.; Scaramelli, A.; Segreto, E.; Stefan, D.; Stepaniak, J.; Sulej, R.; Suvorova, O.; Terrani, M.; Tlisov, D.; Van de Water, R.G.; Trinchero, G.; Turcato, M.; Varanini, F.; Ventura, S.; Vignoli, C.; Wang, H.G.; Yang, X.; Zani, A.; Zaremba, K; Benettoni, M.; Bernardini, P.; Bertolin, A.; Brugnera, R.; Calabrese, M.; Cecchetti, A.; Cecchini, S.; Collazuol, G.; Creti, P.; Corso, F.Dal; Del Prete, A.; De Mitri, I.; De Robertis, G.; De Serio, M.; Esposti, L.Degli; Di Ferdinando, D.; Dore, U.; Dusini, S.; Fabbricatore, P.; Fanin, C.; Fini, R.A.; Fiore, G.; Garfagnini, A.; Giacomelli, G.; Giacomelli, R.; Guandalini, C.; Guerzoni, M.; Kose, U.; Laurenti, G.; Laveder, M.; Lippi, I.; Loddo, F.; Longhin, A.; Loverre, P.; Mancarella, G.; Mandrioli, G.; Margiotta, A.; Marsella, G.; Mauri, N.; Medinaceli, E.; Mengucci, A.; Mezzetto, M.; Michinelli, R.; Muciaccia, M.T.; Orecchini, D.; Paoloni, A.; Papadia, G.; Pastore, A.; Patrizii, L.; Pozzato, M.; Rosa, G.; Sahnounm, Z.; Simone, S.; Sioli, M.; Sirri, G.; Spurio, M.; Stanco, L.; Surdo, A.; Tenti, M.; Togo, V.; Ventura, M.; Zago, M.

    2012-01-01

    A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly comple...

  3. Isolation and Characterization of Human Mesenchymal Stem Cells From Facet Joints and Interspinous Ligaments.

    Science.gov (United States)

    Kristjánsson, Baldur; Limthongkul, Worawat; Yingsakmongkol, Wicharn; Thantiworasit, Pattarawat; Jirathanathornnukul, Napaphat; Honsawek, Sittisak

    2016-01-01

    A descriptive in vitro study on isolation and differentiation of human mesenchymal stem cells (MSCs) derived from the facet joints and interspinous ligaments. To isolate cells from the facet joints and interspinous ligaments and investigate their surface marker profile and differentiation potentials. Lumbar spinal canal stenosis and ossification of the posterior longitudinal ligament are progressive conditions characterized by the hypertrophy and ossification of ligaments and joints within the spinal canal. MSCs are believed to play a role in the advancement of these diseases and the existence of MSCs has been demonstrated within the ligamentum flavum and posterior longitudinal ligament. The aim of this study was to investigate whether these cells could also be found within facet joints and interspinous ligaments. Samples were harvested from 10 patients undergoing spinal surgery. The MSCs from facet joints and interspinous ligaments were isolated using direct tissue explant technique. Cell surface antigen profilings were performed via flow cytometry. Their lineage differentiation potentials were analyzed. The facet joints and interspinous ligaments-derived MSCs have the tri-lineage potential to be differentiated into osteogenic, adipogenic, and chondrogenic cells under appropriate inductions. Flow cytometry analysis revealed both cell lines expressed MSCs markers. Both facet joints and interspinous ligaments-derived MSCs expressed marker genes for osteoblasts, adipocytes, and chondrocytes. The facet joints and interspinous ligaments may provide alternative sources of MSCs for tissue engineering applications. The facet joints and interspinous ligaments-derived MSCs are part of the microenvironment of the human ligaments of the spinal column and might play a crucial role in the development and progression of degenerative spine conditions.

  4. The role of mechanical loading in ligament tissue engineering.

    Science.gov (United States)

    Benhardt, Hugh A; Cosgriff-Hernandez, Elizabeth M

    2009-12-01

    Tissue-engineered ligaments have received growing interest as a promising alternative for ligament reconstruction when traditional transplants are unavailable or fail. Mechanical stimulation was recently identified as a critical component in engineering load-bearing tissues. It is well established that living tissue responds to altered loads through endogenous changes in cellular behavior, tissue organization, and bulk mechanical properties. Without the appropriate biomechanical cues, new tissue formation lacks the necessary collagenous organization and alignment for sufficient load-bearing capacity. Therefore, tissue engineers utilize mechanical conditioning to guide tissue remodeling and improve the performance of ligament grafts. This review provides a comparative analysis of the response of ligament and tendon fibroblasts to mechanical loading in current bioreactor studies. The differential effect of mechanical stimulation on cellular processes such as protease production, matrix protein synthesis, and cell proliferation is examined in the context of tissue engineering design.

  5. The Gore-Tex prosthetic ligament as a salvage procedure in deficient knees

    NARCIS (Netherlands)

    Roolker, W.; Patt, T. W.; van Dijk, C. N.; Vegter, M.; Marti, R. K.

    2000-01-01

    The purpose of this study was to evaluate the results of prosthetic ligament replacement of the anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) with the Gore-Tex polytetrafluorethyene prosthesis (W.L. Gore and Co., Flagstaff, Ariz. ) in 52 patients (54 knees). All patients

  6. Allogeneic versus autologous derived cell sources for use in engineered bone-ligament-bone grafts in sheep anterior cruciate ligament repair.

    Science.gov (United States)

    Mahalingam, Vasudevan D; Behbahani-Nejad, Nilofar; Horine, Storm V; Olsen, Tyler J; Smietana, Michael J; Wojtys, Edward M; Wellik, Deneen M; Arruda, Ellen M; Larkin, Lisa M

    2015-03-01

    The use of autografts versus allografts for anterior cruciate ligament (ACL) reconstruction is controversial. The current popular options for ACL reconstruction are patellar tendon or hamstring autografts, yet advances in allograft technologies have made allogeneic grafts a favorable option for repair tissue. Despite this, the mismatched biomechanical properties and risk of osteoarthritis resulting from the current graft technologies have prompted the investigation of new tissue sources for ACL reconstruction. Previous work by our lab has demonstrated that tissue-engineered bone-ligament-bone (BLB) constructs generated from an allogeneic cell source develop structural and functional properties similar to those of native ACL and vascular and neural structures that exceed those of autologous patellar tendon grafts. In this study, we investigated the effectiveness of our tissue-engineered ligament constructs fabricated from autologous versus allogeneic cell sources. Our preliminary results demonstrate that 6 months postimplantation, our tissue-engineered auto- and allogeneic BLB grafts show similar histological and mechanical outcomes indicating that the autologous grafts are a viable option for ACL reconstruction. These data indicate that our tissue-engineered autologous ligament graft could be used in clinical situations where immune rejection and disease transmission may preclude allograft use.

  7. Geometrik Yapıların İnşasında Pergel ve Çizgecin Kullanımı

    OpenAIRE

    Erduran, Ayten; Yeşildere, Sibel

    2010-01-01

    Bu yapıda üç matematik öğretinin pergel ve çizgeçmenin geometrik yapıları süreçleri incelenmektedir. Öğretmenlerin geometri yapı yapımı ve ilgili dersleri video kamera ile kaydedilmiş ve derslerdeki öğretmen-öğrenci-araç üçlüsü arasındaki etkileşim incelenmiştir. Ders Kitaplığı içeren öğretmenlerle görüşmeler yapıldı. Çalışmada üç matematik öğretmeninin pergel ve çizgeci geometrik yapılar yapı mühendisliği. Araştırma pergel ve çizgeçle geometrik yapıların inşasına ezbere bir anlayışla öğretme...

  8. Biomechanical analysis of ankle ligamentous sprain injury cases from televised basketball games: Understanding when, how and why ligament failure occurs.

    Science.gov (United States)

    Panagiotakis, Emmanouil; Mok, Kam-Ming; Fong, Daniel Tik-Pui; Bull, Anthony M J

    2017-12-01

    Ankle sprains due to landing on an opponent's foot are common in basketball. There is no analysis to date that provides a quantification of this injury mechanism. The aim of this study was to quantify the kinematics of this specific injury mechanism and relate this to lateral ankle ligament biomechanics. Case series. The model-based image-matching technique was used to quantify calcaneo-fibular-talar kinematics during four ankle inversion sprain injury incidents in televised NBA basketball games. The four incidents follow the same injury pattern in which the players of interest step onto an opponent's foot with significant inversion and a diagnosed ankle injury. A geometric analysis was performed to calculate the in vivo ligament strains and strain rates for the anterior talofibular ligament (ATFL) and the calcaneofibular ligament (CFL). Despite the controlled selection of cases, the results show that there are two distinct injury mechanisms: sudden inversion and internal rotation with low levels of plantarflexion; and a similar mechanism without internal rotation. The first of these mechanisms results in high ATFL and CFL strains, whereas the second of these strains the CFL in isolation. The injury mechanism combined with measures of the ligament injury in terms of percentage of strain to failure correlate directly with the severity of the injury quantified by return-to-sport. The opportunity to control excessive internal rotation through proprioceptive training and/or prophylactic footwear or bracing could be utilised to reduce the severity of common ankle injuries in basketball. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. CT anatomy of right phrenic nerve and pulmonary ligament

    International Nuclear Information System (INIS)

    Berkmen, Y.M.; Kazam, E.; Auh, Y.

    1988-01-01

    The relationship between the right phrenic nerve and the right pulmonary ligament was studied in eight cadavers and 100 computed tomographic (CT) examinations. The pulmonary ligament originates below the inferior pulmonary vein and is constantly posterior to the inferior vena cava. The lower end of the right phrenic nerve, on the other hand, descends over the lateral surface of the inferior vena cava, accompanied by the right cardiophrenic artery. The nerve spreads over the diaphragm within a thick parietal pleural fold, wrapped in a fatty tissue, and this should not be confused with pulmonary ligament on CT

  10. An Ecological Study of Anterior Cruciate Ligament Reconstruction, Part 2: Functional Performance Tests Correlate With Return-to-Sport Outcomes.

    Science.gov (United States)

    McGrath, Timothy M; Waddington, Gordon; Scarvell, Jennie M; Ball, Nick; Creer, Rob; Woods, Kevin; Smith, Damian; Adams, Roger

    2017-02-01

    Additional high-quality prospective studies are needed to better define the objective criteria used in relation to return-to-sport decisions after anterior cruciate ligament (ACL) reconstruction in active populations. To investigate prospectively the relationship between functional performance test results at 24 weeks postoperative and return-to-sport activity (Tegner activity score) at 12 and 24 months, respectively, after synthetic (ligament advanced reinforcement system [LARS]) and autograft (doubled semitendinosus/gracilis [2ST/2GR]) ACL reconstructions. Case series; Level of evidence, 4. A total of 64 patients who underwent ACL reconstruction (32 LARS, 32 2ST/2GR autograft; mean age, 27.9 years; body mass index [BMI], 24.9 kg/m 2 ) were assessed preoperatively and at staged intervals postoperatively up to 24 weeks for isokinetic testing of quadriceps and hamstring average power per repetition at 60 deg/s and 180 deg/s, a battery of hop tests, peak vertical ground-reaction force (vGRF), and time to peak vGRF (in seconds) during a step- and jump-down task onto a force platform and peak speed (m/s) using a global positioning system (GPS unit) during a running task. A cohort of 32 healthy matched participants (mean age, 26.31 years; BMI, 25.7 kg/m 2 ) were also tested to act as reference. Pearson correlation was calculated to assess correlation of each performance measure at 24 weeks postoperative with activity outcomes (Tegner score) at 12 and 24 months. The strongest correlation between physical performance tests and return-to-sport outcomes was observed with peak speed during running. Large correlations were also observed for hamstring isokinetic power and hop test for distance. Moderate correlations were observed for timed hop, peak vGRF during a jump-down task, and quadriceps isokinetic power. No statistical correlations were observed for time to peak vGRF during a step-down and jump-down task as well as peak vGRF during a step-down task. When the performance

  11. In Vivo Study of Ligament-Bone Healing after Anterior Cruciate Ligament Reconstruction Using Autologous Tendons with Mesenchymal Stem Cells Affinity Peptide Conjugated Electrospun Nanofibrous Scaffold

    Directory of Open Access Journals (Sweden)

    Jingxian Zhu

    2013-01-01

    Full Text Available Electrospinning nanofibrous scaffold was commonly used in tissue regeneration recently. Nanofibers with specific topological characteristics were reported to be able to induce osteogenic differentiation of MSCs. In this in vivo study, autologous tendon grafts with lattice-like nanofibrous scaffold wrapping at two ends of autologous tendon were used to promote early stage of ligament-bone healing after rabbit ACL reconstruction. To utilize native MSCs from bone marrow, an MSCs specific affinity peptide E7 was conjugated to nanofibrous meshes. After 3 months, H-E assessment and specific staining of collagen type I, II, and III showed direct ligament-bone insertion with typical four zones (bone, calcified fibrocartilage, fibrocartilage, and ligament in bioactive scaffold reconstruction group. Diameters of bone tunnel were smaller in nanofibrous scaffold conjugated E7 peptide group than those in control group. The failure load of substitution complex also indicated a stronger ligament-bone insertion healing using bioactive scaffold. In conclusion, lattice-like nanofibrous scaffold with specific MSCs affinity peptide has great potential in promoting early stage of ligament-bone healing after ACL reconstruction.

  12. Injuries to the Collateral Ligaments of the Metacarpophalangeal Joint of the Thumb, Including Simultaneous Combined Thumb Ulnar and Radial Collateral Ligament Injuries, in National Football League Athletes.

    Science.gov (United States)

    Werner, Brian C; Belkin, Nicole S; Kennelly, Steve; Weiss, Leigh; Barnes, Ronnie P; Rodeo, Scott A; Warren, Russell F; Hotchkiss, Robert N

    2017-01-01

    Thumb collateral ligament injuries occur frequently in the National Football League (NFL). In the general population or in recreational athletes, pure metacarpophalangeal (MCP) abduction or adduction mechanisms yield isolated ulnar collateral ligament (UCL) and radial collateral ligament (RCL) tears, respectively, while NFL athletes may sustain combined mechanism injury patterns. To evaluate the incidence of simultaneous combined thumb UCL and RCL tears among all thumb MCP collateral ligament injuries in NFL athletes on a single team. Case series; Level of evidence, 4. A retrospective review of all thumb injuries on a single NFL team from 1991 to 2014 was performed. All players with a thumb MCP collateral ligament injury were included. Collateral ligament injuries were confirmed by review of both physical examination findings and magnetic resonance imaging. Player demographics, surgical details, and return-to-play data were obtained from the team electronic medical record and surgeons' records. A total of 36 thumbs in 32 NFL players were included in the study, yielding an incidence of 1.6 thumb MCP collateral ligament injuries per year on a single NFL team. Of these, 9 thumbs (25%) had a simultaneous combined UCL and RCL tear injury pattern confirmed on both physical examination and MRI. The remaining 27 thumbs (75%) were isolated UCL injuries. All combined UCL/RCL injuries required surgery due to dysfunction from instability; 63.0% of isolated UCL injuries required surgical repair ( P = .032) due to continued pain and dysfunction from instability. Repair, when required, was delayed until the end of the season. All players with combined UCL/RCL injuries and isolated UCL injuries returned to play professional football the following season. Simultaneous combined thumb UCL and RCL tear is a previously undescribed injury pattern that occurred in 25% of thumb MCP collateral ligament injuries on a single NFL team over a 23-year period. All players with combined thumb UCL

  13. Keratinocyte growth factor mRNA expression in periodontal ligament fibroblasts

    DEFF Research Database (Denmark)

    Dabelsteen, S; Wandall, H H; Grøn, B

    1997-01-01

    Keratinocyte growth factor (KGF) is a fibroblast growth factor which mediates epithelial growth and differentiation. KGF is expressed in subepithelial fibroblasts, but generally not in fibroblasts of deep connective tissue, such as fascia and ligaments. Here we demonstrate that KGF mRNA is expres......Keratinocyte growth factor (KGF) is a fibroblast growth factor which mediates epithelial growth and differentiation. KGF is expressed in subepithelial fibroblasts, but generally not in fibroblasts of deep connective tissue, such as fascia and ligaments. Here we demonstrate that KGF m......RNA is expressed in periodontal ligament fibroblasts, and that the expression is increased upon serum stimulation. Fibroblasts from human periodontal ligament, from buccal mucosa, from gingiva, and from skin were established from explants. Alkaline phosphatase activity was used as an indicator of the periodontal...

  14. Visualization of Penile Suspensory Ligamentous System Based on Visible Human Data Sets

    Science.gov (United States)

    Chen, Xianzhuo; Wu, Yi; Tao, Ling; Yan, Yan; Pang, Jun; Zhang, Shaoxiang; Li, Shirong

    2017-01-01

    Background The aim of this study was to use a three-dimensional (3D) visualization technology to illustrate and describe the anatomical features of the penile suspensory ligamentous system based on the Visible Human data sets and to explore the suspensory mechanism of the penis for the further improvement of the penis-lengthening surgery. Material/Methods Cross-sectional images retrieved from the first Chinese Visible Human (CVH-1), third Chinese Visible Human (CVH-3), and Visible Human Male (VHM) data sets were used to segment the suspensory ligamentous system and its adjacent structures. The magnetic resonance imaging (MRI) images of this system were studied and compared with those from the Visible Human data sets. The 3D models reconstructed from the Visible Human data sets were used to provide morphological features of the penile suspensory ligamentous system and its related structures. Results The fundiform ligament was a superficial, loose, fibro-fatty tissue which originated from Scarpa’s fascia superiorly and continued to the scrotal septum inferiorly. The suspensory ligament and arcuate pubic ligament were dense fibrous connective tissues which started from the pubic symphysis and terminated by attaching to the tunica albuginea of the corpora cavernosa. Furthermore, the arcuate pubic ligament attached to the inferior rami of the pubis laterally. Conclusions The 3D model based on Visible Human data sets can be used to clarify the anatomical features of the suspensory ligamentous system, thereby contributing to the improvement of penis-lengthening surgery. PMID:28530218

  15. Review of the Nomenclature of the Retaining Ligaments of the Cheek: Frequently Confused Terminology

    Directory of Open Access Journals (Sweden)

    Yeui Seok Seo

    2017-07-01

    Full Text Available Since the time of its inception within facial anatomy, wide variability in the terminology as well as the location and extent of retaining ligaments has resulted in confusion over nomenclature. Confusion over nomenclature also arises with regard to the subcutaneous ligamentous attachments, and in the anatomic location and extent described, particularly for zygomatic and masseteric ligaments. Certain historical terms—McGregor’s patch, the platysma auricular ligament, parotid cutaneous ligament, platysma auricular fascia, temporoparotid fasica (Lore’s fascia, anterior platysma-cutaneous ligament, and platysma cutaneous ligament—delineate retaining ligaments of related anatomic structures that have been conceptualized in various ways. Confusion around the masseteric cutaneous ligaments arises from inconsistencies in their reported locations in the literature because the size and location of the parotid gland varies so much, and this affects the relationship between the parotid gland and the fascia of the masseter muscle. For the zygomatic ligaments, there is disagreement over how far they extend, with descriptions varying over whether they extend medially beyond the zygomaticus minor muscle. Even the ‘main’ zygomatic ligament’s denotation may vary depending on which subcutaneous plane is used as a reference for naming it. Recent popularity in procedures using threads or injectables has required not only an accurate understanding of the nomenclature of retaining ligaments, but also of their location and extent. The authors have here summarized each retaining ligament with a survey of the different nomenclature that has been introduced by different authors within the most commonly cited published papers.

  16. Experimental observation of an extremely high electron lifetime with the ICARUS-T600 LAr-TPC

    CERN Document Server

    Antonello, M; Benetti, P; Boffelli, F; Bubak, A; Calligarich, E; Centro, S; Cesana, A; Cieslik, K; Cline, D B; Cocco, A G; Dabrowska, A; Dermenev, A; Dolfini, R; Falcone, A; Farnese, C; Fava, A; Ferrari, A; Fiorillo, G; Gibin, D; Gninenko, S; Guglielmi, A; Haranczyk, M; Holeczek, J; Kirsanov, M; Kisiel, J; Kochanek, I; Lagoda, J; Mania, S; Menegolli, A; Meng, G; Montanari, C; Otwinowski, S; Picchi, P; Pietropaolo, F; Plonski, P; Rappoldi, A; Raselli, G L; Rossella, M; Rubbia, C; Sala, P; Scaramelli, A; Segreto, E; Sergiampietri, F; Stefan, D; Sulej, R; Szarska, M; Terrani, M; Torti, M; Varanini, F; Ventura, S; Vignoli, C; Wang, H; Yang, X; Zalewska, A; Zani, A; Zaremba, K

    2014-01-01

    The ICARUS T600 detector, the largest liquid Argon Time Projection Chamber (LAr-TPC) realized after many years of RD activities, was installed and successfully operated for 3 years at the INFN Gran Sasso underground Laboratory. One of the most important issues was the need of an extremely low residual electronegative impurity content in the liquid Argon, in order to transport the free electrons created by the ionizing particles with a very small attenuation along the drift path. The solutions adopted for the Argon re-circulation and purification systems have permitted to reach impressive results in terms of Argon purity and a free electron lifetime exceeding 15 ms, corresponding to about 20 parts per trillion of equivalent O2 contamination, a milestone for any future project involving LAr-TPC's and the development of higher detector mass scales.

  17. Biomechanical properties of interosseous proximal carpal row ligaments.

    Science.gov (United States)

    Nikolopoulos, Fotios; Apergis, Emmanuel; Kefalas, Vassilios; Zoubos, Aristides; Soucacos, Panayiotis; Papagelopoulos, Panayiotis

    2011-05-01

    The Scapholunate (S-L) and Lunotriquetrum (L-Tr) ligaments have been extensively studied in the literature. A wide range of measurements has been reported for ultimate load and stiffness with different mechanical protocols. In this study, we examined the mechanical properties of both ligaments harvested from the same wrist. Fifteen fresh cadaver wrists were used to harvest eight S-L and four L-Tr. Testing was performed in quasi-static loading in a well defined direction for each ligament system. The ultimate load for S-L was 68-210 N with a mean value of 147 ± 54 N and a stiffness of 35.7 ± 9.6 N/mm. For L-Tr the ultimate load was 122-179 N with a mean value of 150 ± 24 N and a stiffness of 192 ± 60 N/mm. The two ligaments had nearly the same ultimate load, but the L-Tr had a higher stiffness (p = 0.05). These findings could be useful to assess the appropriate autologous autografts for reconstruction of the S-L and L-Tr. Copyright © 2010 Orthopaedic Research Society.

  18. Anatomy and histology of the transverse humeral ligament.

    Science.gov (United States)

    Snow, Brian J; Narvy, Steven J; Omid, Reza; Atkinson, Roscoe D; Vangsness, C Thomas

    2013-10-01

    The classic literature describes the transverse humeral ligament (THL) as a distinct anatomic structure with a role in biceps tendon stability; however, recent literature suggests that it is not a distinct anatomic structure. The purpose of this study was to evaluate the gross and microscopic anatomy of the THL, including a specific investigation of the histology of this ligament. Thirty frozen, embalmed cadaveric specimens were dissected to determine the gross anatomy of the THL. Seven specimens were evaluated histologically for the presence of mechanoreceptors and free nerve endings. Two tissue layers were identified in the area described as the THL. In the deep layer, fibers of the subscapularis tendon were found to span the bicipital groove with contributions from the coracohumeral ligament and the supraspinatus tendon. Superficial to this layer was a fibrous fascial covering consisting of distinct bands of tissue. Neurohistology staining revealed the presence of free nerve endings but no mechanoreceptors. This study's findings demonstrate that the THL is a distinct structure continuous with the rotator cuff tendons and the coracohumeral ligament. The finding of free nerve endings in the THL suggests a potential role as a shoulder pain generator. Copyright 2013, SLACK Incorporated.

  19. Sonography of injury of the ulnar collateral ligament of the elbow - initial experience

    International Nuclear Information System (INIS)

    Miller, Theodore T.; Adler, Ronald S.; Friedman, Lawrence

    2004-01-01

    The purpose of this study is to describe the sonographic appearance of injuries of the ulnar collateral ligament (UCL) of the elbow. Eight non-professional male baseball pitchers, ages 13-35 years, with medial elbow pain and clinical suspicion of ulnar collateral ligament injury, were referred for imaging. All eight underwent sonography of the affected and contralateral asymptomatic elbow, and six also underwent MR imaging. Neither valgus stress nor power Doppler was used during the sonographic examinations. Time from onset of symptoms to imaging was 1.5 weeks to 6 months. Three patients had surgical confirmation of their injuries, with time from imaging to surgery of 2 days to 9 months. In four patients, the UCL was ruptured, manifest sonographically in three cases as discontinuity of the normally hyperechoic ligament with anechoic fluid in the gap and in one case as non-visualization of the ligament with heterogeneous echogenicity in the expected location of the ligament. Two adolescent patients had avulsions of the UCL from the medial epicondyle, with sonographic demonstration of the avulsed echogenic bony fragment in both cases. One patient had a mild sprain, manifest as mild thickening and decreased echogenicity of the ligament sonographically compared with the contralateral normal elbow, with mild surrounding hypoechoic edema. The eighth patient had a small partial tear of the deep surface of the distal aspect of the ligament, visualized as a hypoechoic focus between the deep surface of the ligament and its ulnar attachment. Tears of the ulnar collateral ligament are manifested sonographically as non-visualization of the ligament or alteration of the normal morphology. (orig.)

  20. The anatomy of the coracohumeral ligament and its relation to the subscapularis muscle.

    Science.gov (United States)

    Arai, Ryuzo; Nimura, Akimoto; Yamaguchi, Kumiko; Yoshimura, Hideya; Sugaya, Hiroyuki; Saji, Takahiko; Matsuda, Shuichi; Akita, Keiichi

    2014-10-01

    Only a few reports describe the extension of the coracohumeral ligament to the subscapularis muscle. The purposes of this study were to histo-anatomically examine the structure between the ligament and subscapularis and to discuss the function of the ligament. Nineteen intact embalmed shoulders were used. In 9 shoulders, the expansion of the ligament was anatomically observed, and in 6 of these 9, the muscular tissue of the supraspinatus and subscapularis was removed to carefully examine the attachments to the tendons of these muscles. Five shoulders were frozen and sagittally sectioned into 3-mm-thick slices. After observation, histologic analysis was performed on 3 of these shoulders. In the remaining 5 shoulders, the coracoid process was harvested to investigate the ligament origin. The coracohumeral ligament originated from the horizontal limb and base of the coracoid process and enveloped the cranial part of the subscapularis muscle. The superficial layer of the ligament covered a broad area of the anterior surface of the muscle. Laterally, it protruded between the long head of the biceps tendon and subscapularis and attached to the tendinous floor, which extended from the subscapularis insertion. Histologically, the ligament consisted of irregular and sparse fibers abundant in type III collagen. The coracohumeral ligament envelops the whole subscapularis muscle and insertion and seems to function as a kind of holder for the subscapularis and supraspinatus muscles. The ligament is composed of irregular and sparse fibers and contains relatively rich type III collagen, which would suggest flexibility. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. MRI features of the anterolateral ligament of the knee

    International Nuclear Information System (INIS)

    Taneja, Atul K.; Miranda, Frederico C.; Braga, Cesar A.P.; Hartmann, Luiz G.C.; Santos, Durval C.B.; Rosemberg, Laercio A.; Gill, Corey M.

    2015-01-01

    Evaluate the visibility and describe the anatomical features of the anterolateral ligament of the knee using MRI. Magnetic resonance imaging examinations of the knee were independently reviewed by two musculoskeletal radiologists and assessed for the visibility of the anterolateral ligament under direct cross-referencing of axial and coronal images as complete, partial, or non-visible. Distal insertion site (tibial, meniscal), distance to lateral tibial plateau, measurements (length, width, thickness), and associated imaging findings were also tabulated. Clinical and surgical records were also reviewed. Seventy MRI scans from 60 consecutive subjects were included in the study. Mean age was 40 years, body mass 74.9 kg, and height 1.72 m. The subject population was 53 % male, most of the knees were from the left side (51 %), and chronic pain was the main clinical symptom (40 %). Nine knees (13 %) had undergone previous surgery. The anterolateral ligament was identified in 51 % of the knees: completely visible in 11 % and partially visible in 40 %. In all visible cases, the distal insertion site was identified on the tibia, with a mean distance of 5.7 mm to the plateau. A completely visible ligament had a mean length of 33.2 mm, thickness of 5.6 mm, and width of 1.9 mm. Inter-observer agreement for ligament presence was significant (κ = 0.7). Statistical analyses showed a trend to be more visible in men, with a longer length compared with women. Magnetic resonance imaging clearly identifies the anterolateral ligament of the knee in slightly more than half of cases, being partially visible in most of them. In all cases, a tibial insertion is characterized. (orig.)

  2. MRI features of the anterolateral ligament of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Taneja, Atul K. [Hospital Israelita Albert Einstein, Musculoskeletal Radiology Division, Imaging Department, Sao Paulo, SP (Brazil); Hospital do Coracao (HCor), and Teleimagem, Musculoskeletal Imaging, Diagnostic Center, Sao Paulo, SP (Brazil); Miranda, Frederico C.; Braga, Cesar A.P.; Hartmann, Luiz G.C.; Santos, Durval C.B.; Rosemberg, Laercio A. [Hospital Israelita Albert Einstein, Musculoskeletal Radiology Division, Imaging Department, Sao Paulo, SP (Brazil); Gill, Corey M. [Department of Neurology and Cancer Center, Pappas Center for Neuro-Oncology, Boston, MA (United States)

    2014-11-27

    Evaluate the visibility and describe the anatomical features of the anterolateral ligament of the knee using MRI. Magnetic resonance imaging examinations of the knee were independently reviewed by two musculoskeletal radiologists and assessed for the visibility of the anterolateral ligament under direct cross-referencing of axial and coronal images as complete, partial, or non-visible. Distal insertion site (tibial, meniscal), distance to lateral tibial plateau, measurements (length, width, thickness), and associated imaging findings were also tabulated. Clinical and surgical records were also reviewed. Seventy MRI scans from 60 consecutive subjects were included in the study. Mean age was 40 years, body mass 74.9 kg, and height 1.72 m. The subject population was 53 % male, most of the knees were from the left side (51 %), and chronic pain was the main clinical symptom (40 %). Nine knees (13 %) had undergone previous surgery. The anterolateral ligament was identified in 51 % of the knees: completely visible in 11 % and partially visible in 40 %. In all visible cases, the distal insertion site was identified on the tibia, with a mean distance of 5.7 mm to the plateau. A completely visible ligament had a mean length of 33.2 mm, thickness of 5.6 mm, and width of 1.9 mm. Inter-observer agreement for ligament presence was significant (κ = 0.7). Statistical analyses showed a trend to be more visible in men, with a longer length compared with women. Magnetic resonance imaging clearly identifies the anterolateral ligament of the knee in slightly more than half of cases, being partially visible in most of them. In all cases, a tibial insertion is characterized. (orig.)

  3. Three-dimensional anatomical analysis of ligamentous attachments of the second through fifth carpometacarpal joints

    International Nuclear Information System (INIS)

    Nanno, Mitsuhiko; Sawaizumi, Takuya; Horiguchi, Gen; Ito, Hiromoto

    2007-01-01

    The purpose of this study is to identify, measure, and show the anatomic locations and areas of specific ligamentous attachments and paths of the second through fifth carpometacarpal (CMC) joints on a three-dimensional (3-D) surface model. Ten fresh-frozen cadaver wrists were used to dissect and identify the second through fifth CMC ligaments. The ligamentous attachments and whole bone surfaces were digitized three-dimensionally, and their areas were calculated. The attachments of each ligament were represented in a model in which their surfaces, as seen on computed tomography (CT), were overlaid with a digitized 3-D surface, and they were also visually demonstrated with a specific color on 3-D images of the bones. A total of 9 dorsal and 9 volar CMC ligaments and 1 CMC interosseous ligament were identified in the second through fifth CMC joints. An intra-articular ligament between the third and fourth metacarpals (MCs) and the capitate and hamate was also identified. In addition, 5 dorsal and 5 volar intermetacarpal ligaments and 3 intermetacarpal interosseous ligaments were also identified in the second through fifth intermetacarpal joints. A previously undescribed volar intermetacarpal ligament was found located between the third, fourth, and fifth MC bases. The anatomic 3-D attachment sites of the second through fifth CMC ligaments were visually depicted qualitatively, and their areas were quantified. This study has improved the knowledge and understanding of the normal anatomy and its impact on the mechanics of the second through fifth CMC joints. This 3-D information should facilitate the accurate assessment of radiographic images and the treatment of various injuries seen in the second through fifth CMC joints when performing ligament reconstruction, repair, osteochondral grafting, and arthroscopy. (author)

  4. Internet and Its Contributions to Library Services Internet: Kütüphane Hizmetlerine Katkıları

    Directory of Open Access Journals (Sweden)

    Yaşar Çelik

    1995-06-01

    Full Text Available This paper examines the major Internet services such as email, telnet and ftp and describes various information discovery and retrieval tools such as gopher, WAIS, and WWW. It also discusses the contributions of the Internet to library and information services. Bu makalede elektronik posta, telnet ve ftp gibi belli başlı Internet hizmetleri tanıtılmış, çeşitli bilgi keşfetme ve erişim araçları (gopher, WAIS, WWW açıklanmıştır. İnternet'in kütüphane hizmetlerine katkıları kısaca tartışılmıştır.

  5. LArGe: active background suppression using argon scintillation for the GERDA 0νββ-experiment

    International Nuclear Information System (INIS)

    Agostini, M.; Budjas, D.; Schoenert, S.; Barnabe-Heider, M.; Cattadori, C.; Gangapshev, A.; Gusev, K.; Heisel, M.; Smolnikov, A.; Junker, M.; Klimenko, A.; Lubashevskiy, A.; Pelczar, K.; Zuzel, G.

    2015-01-01

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed into liquid argon (1 m 3 , 1.4tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10 3 have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12 - 4.6) x 10 -2 cts/(keV kg year) (90 % C.L.), which is at the level of GERDA Phase I. Furthermore, for the first time we monitor the natural 42 Ar abundance (parallel to GERDA), and have indication for the 2νββ-decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in GERDA Phase II is pursued. (orig.)

  6. LArGe: active background suppression using argon scintillation for the Gerda 0ν β β -experiment

    Science.gov (United States)

    Agostini, M.; Barnabé-Heider, M.; Budjáš, D.; Cattadori, C.; Gangapshev, A.; Gusev, K.; Heisel, M.; Junker, M.; Klimenko, A.; Lubashevskiy, A.; Pelczar, K.; Schönert, S.; Smolnikov, A.; Zuzel, G.

    2015-10-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for future application in the Gerda experiment. Similar to Gerda, LArGe operates bare germanium detectors submersed into liquid argon (1 m^3, 1.4 tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to Gerda. Suppression factors of a few times 10^3 have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12-4.6)× 10^{-2} cts/(keV kg year) (90 % C.L.), which is at the level of Gerda Phase I. Furthermore, for the first time we monitor the natural ^{42}Ar abundance (parallel to Gerda), and have indication for the 2ν β β -decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in Gerda Phase II is pursued.

  7. LArGe: active background suppression using argon scintillation for the GERDA 0νββ-experiment

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, M.; Budjas, D.; Schoenert, S. [Technische Universitaet Muenchen, Munich (Germany); Barnabe-Heider, M. [Technische Universitaet Muenchen, Munich (Germany); Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Cattadori, C. [Universita degli Studi di Milano, Milan (Italy); INFN, Milan (Italy); Gangapshev, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Institut for Nuclear Research, Moscow (Russian Federation); Gusev, K. [Technische Universitaet Muenchen, Munich (Germany); Joint Institut for Nuclear Research, Dubna (Russian Federation); National Research Center Kurchatov Institut, Moscow (Russian Federation); Heisel, M.; Smolnikov, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Junker, M. [Laboratori Nazionali del Gran Sasso, Assergi (Italy); Klimenko, A.; Lubashevskiy, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Joint Institut for Nuclear Research, Dubna (Russian Federation); Pelczar, K. [Jagellonian University, Cracow (Poland); Zuzel, G. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Jagellonian University, Cracow (Poland)

    2015-10-15

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed into liquid argon (1 m{sup 3}, 1.4tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12 - 4.6) x 10{sup -2} cts/(keV kg year) (90 % C.L.), which is at the level of GERDA Phase I. Furthermore, for the first time we monitor the natural {sup 42}Ar abundance (parallel to GERDA), and have indication for the 2νββ-decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in GERDA Phase II is pursued. (orig.)

  8. Development of new readout electronics for the ATLAS LAr Calorimeter at the sLHC

    CERN Document Server

    Strässner, A

    2009-01-01

    The readout of the ATLAS Liquid Argon (LAr) calorimeter is a complex multi-channel system to amplify, shape, digitize and process signals of the detector cells. The current on-detector electronics is not designed to sustain the ten times higher radiation levels expected at sLHC in the years beyond 2019/2020, and will be replaced by new electronics with a completely different readout scheme. The future on-detector electronics is planned to send out all data continuously at each bunch crossing, as opposed to the current system which only transfers data at a trigger-accept signal. Multiple high-speed and radiation-resistant optical links will transmit 100 Gb/s per front-end board. The off-detector processing units will not only process the data in real-time and provide digital data buffering, but will also implement trigger algorithms. An overview about the various components necessary to develop such a complex system is given. The current R&D activities and architectural studies of the LAr Calorimeter group...

  9. Stress changes of lateral collateral ligament at different

    Directory of Open Access Journals (Sweden)

    ZHONG Yan-lin

    2011-04-01

    Full Text Available 【Abstract】 Objective: To create a 3-dimensional finite element model of knee ligaments and to analyse the stress changes of lateral collateral ligament (LCL with or without displaced movements at different knee flexion conditions. Methods: A four-major-ligament contained knee specimen from an adult died of skull injury was prepared for CT scanning with the detectable ligament insertion footprints, locations and orientations precisely marked in advance. The CT scanning images were converted to a 3-dimensional model of the knee with the 3-dimensional reconstruction technique and transformed into finite element model by the software of ANSYS. The model was validated using experimental and numerical results obtained by other scientists. The natural stress changes of LCL at five different knee flexion angles (0°, 30°, 60°, 90°, 120° and under various motions of anterior-posterior tibial translation, tibial varus rotation and internal-external tibial rotation were measured. Results: The maximum stress reached to 87%-113% versus natural stress in varus motion at early 30° of knee flexions. The stress values were smaller than the peak value of natural stress at 0° (knee full extension when knee bending was over 60° of flexion in anterior-posterior tibial translation and internal-external rotation. Conclusion: LCL is vulnerable to varus motion in almost all knee bending positions and susceptible to anterior- posterior tibial translation or internal-external rotation at early 30° of knee flexions. Key words: Knee joint; Collateral ligaments; Finite element analysis

  10. Sonoanatomy and injection technique of the iliolumbar ligament.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2012-01-31

    BACKGROUND: The iliolumbar ligament plays an important biomechanic role in anchoring the spine to the pelvic ring and stabilizing the sacroiliac joint. Iliolumbar syndrome is a back pain condition caused by pathology of the iliolumbar ligament. History and physical examination are important in the assessment of back pain, but they lack sufficient specificity. Injection of small volumes of local anesthetic into the structure considered to be the source of the pain (i.e. the iliolumbar ligament) increases the specificity of the diagnostic workup. OBJECTIVE: To describe an ultrasound - guided technique for injecting the iliolumbar ligament. STUDY DESIGN: Case report based on knowledge of topographic anatomy and sonoanatomy. SETTING: Outpatient clinic. METHODS: A patient with a clinical picture suggestive of iliolumbar syndrome was selected. An ultrasound-guided injection of the iliolumbar ligament with local anesthetic was performed. We recorded the patient\\'s subjective assessment of pain and the change in range of movement and pain scores during provocative tests. RESULTS: Following the injection, the patient\\'s pain score decreased, provocation tests became negative, and the range of movement increased. LIMITATIONS: Case report. Target specificity and dispersion of local anesthetic spread not confirmed with an independent technique (i.e. magnetic resonance imaging). CONCLUSIONS: Ultrasound guidance allows the selective deposition of small volumes of local anesthetic into structures believed to cause soft tissue back pain and thus to confirm or exclude the working diagnosis. Further studies are needed to confirm our conclusions and to prove the clinical feasibility of this technique.

  11. Research and Development for a Free-Running Readout System for the ATLAS LAr Calorimeters at the High Luminosity LHC

    CERN Document Server

    Hils, Maximilian; The ATLAS collaboration

    2015-01-01

    The ATLAS Liquid Argon (LAr) Calorimeters were designed and built to measure electromagnetic and hadronic energy in proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to $10^{34} \\text{cm}^{-2} \\text{s}^{-1}$. The High Luminosity LHC (HL-LHC) programme is now developed for up to 5-7 times the design luminosity, with the goal of accumulating an integrated luminosity of $3000~\\text{fb}^{-1}$. In the HL-LHC phase, the increased radiation levels require a replacement of the front-end electronics of the LAr Calorimeters. Furthermore, the ATLAS trigger system is foreseen to increase the trigger accept rate by a factor 10 to 1 MHz and the trigger latency by a factor of 20 which requires a larger data volume to be buffered. Therefore, the LAr Calorimeter read-out will be exchanged with a new front-end and a high bandwidth back-end system for receiving data from all 186.000 channels at 40 MHz LHC bunch-crossing frequency and for off-detector buffering...

  12. In vivo structural and cellular remodeling of engineered bone-ligament-bone constructs used for anterior cruciate ligament reconstruction in sheep.

    Science.gov (United States)

    Florida, Shelby E; VanDusen, Keith W; Mahalingam, Vasudevan D; Schlientz, Aleesa J; Wojtys, Edward M; Wellik, Deneen M; Larkin, Lisa M

    2016-11-01

    Anterior cruciate ligament (ACL) ruptures rank among the most prevalent and costly sports-related injuries. Current tendon grafts used for ACL reconstruction are limited by suboptimal biomechanical properties. We have addressed these issues by engineering multiphasic bone-ligament-bone (BLB) constructs that develop structural and mechanical properties similar to native ACL. The purpose of this study was to examine the acute remodeling process that occurs as the BLB grafts advance toward the adult ligament phenotype in vivo. Thus, we implanted BLB constructs fabricated from male cells into female host sheep and allowed 3, 7, 14, or 28 days (n = 4 at each time point) for recovery. To address whether or not graft-derived cells were even necessary, a subset of BLB constructs (n = 3) were acellularized, implanted, and allowed 28 days for recovery. At each recovery time point, the following histological analyses were performed: picrosirius red staining to assess collagen alignment and immunohistochemistry to assess both graft development and host immune response. Polymerase chain reaction (PCR) analysis, performed on every explanted BLB, was used to detect the presence of graft-derived male cells remaining in the constructs and/or migration into surrounding host tissue. The analysis of the PCR and histology samples revealed a rapid migration of host-derived macrophages and neutrophils into the graft at 3 days, followed by increased collagen density and alignment, vascularization, innervation, and near complete repopulation of the graft with host cells within 28 days. This study provides a greater understanding of the processes of ligament regeneration in our BLB constructs as they remodel toward the adult ligament phenotype.

  13. Mastication and the Postorbital Ligament: Dynamic Strain in Soft Tissues

    Science.gov (United States)

    Herring, Susan W.; Rafferty, Katherine L.; Liu, Zi Jun; Lemme, Michael

    2011-01-01

    Although the FEED database focuses on muscle activity patterns, it is equally suitable for other physiological recording and especially for synthesizing different types of information. The present contribution addresses the interaction between muscle activity and ligamentary stretch during mastication. The postorbital ligament is the thickened edge of a septum dividing the orbital contents from the temporal fossa and is continuous with the temporal fascia. As a tensile element, this fascial complex could support the zygomatic arch against the pull of the masseter muscle. An ossified postorbital bar has evolved repeatedly in mammals, enabling resistance to compression and shear in addition to tension. Although such ossification clearly reinforces the skull against muscle pull, the most accepted explanation is that it helps isolate the orbital contents from contractions of the temporalis muscle. However, it has never been demonstrated that the contraction of jaw muscles deforms the unossified ligament. We examined linear deformation of the postorbital ligament in minipigs, Sus scrofa, along with electromyography of the jaw muscles and an assessment of changes in pressure and shape in the temporalis. During chewing, the ligament elongated (average 0.9%, maximum 2.8%) in synchrony with the contraction of the elevator muscles of the jaw. Although the temporalis bulged outward and created substantial pressure against the braincase, the superficial fibers usually retracted caudally, away from the postorbital ligament. In anesthetized animals, stimulating either the temporalis or the masseter muscle in isolation usually elongated the ligament (average 0.4–0.7%). These results confirm that contraction of the masticatory muscles can potentially distort the orbital contents and further suggest that the postorbital ligament does function as a tension member resisting the pull of the masseter on the zygomatic arch. PMID:21593142

  14. Cold experiments on ligament formation for blast furnace slag granulation

    International Nuclear Information System (INIS)

    Liu Junxiang; Yu Qingbo; Li Peng; Du Wenya

    2012-01-01

    Rotary cup atomization for molten slag granulation is an attractive alternative to water quenching. However, the mechanism of disintegration of molten slag must be assessed. In the present study, a glycerol/water mixture was substituted for molten slag, and the mechanism of ligament formation in a rotary cup was investigated using photos taken by a high-speed camera. The effects of the angular speed and inner depth of the rotary cup on ligament disintegration was investigated. The results showed that one state of disintegration may transform into another state as the angular speed of the rotary cup increases at a given liquid flow rate. During ligament formation, the number of ligaments increased with an increase in the angular speed of the rotary cup, and a decrease in the diameter of ligament and liquid drop was observed. Moreover, the initial point of disintegration of the ligament moved to the lip of the rotary cup as the angular speed increased. An equation describing the relationship between the diameter of the liquid drop and various factors was used to predict the diameter of the liquid drop. A rotary cup with an inner depth of 30 mm was the best choice for granulation. The results of the present study will be useful for designing devices used in molten slag granulation. - Highlights: ►The results can be used in the granulation of molten blast furnace slag. ► The three different states of disintegration occur as the angular speed of rotary cup increases. ► The mechanism of ligament disintegration is analyzed. ► Eq. can be used to predict the diameter of liquid drop. ► A rotary cup with an inner depth of 30 mm is optimal for granulation.

  15. Study on the nuchal ligament ossification on lateral cephalometric radiograph

    International Nuclear Information System (INIS)

    An, Chang Hyeon

    2009-01-01

    The purpose of this study was to assess the prevalence and radiographic characteristics of the nuchal ligament ossification on lateral cephalometric radiographs in Koreans. I review and interpreted the lateral cephalometric radiographs from 4,558 patients (1,857 males and 2,701 females, age range from 2 to 79 years) who visited the Kyungpook National University Dental Hospital from January 1, 2008 to February 3, 2009. I grouped the shapes of nuchal ligament ossification as round, rod-like, and segmented shape. And localized the ossification as the involvement of anterior cervical vertebral body. The data were analyzed by using chi-squared test with two-tailed and at a 5% significance level. Among those who showed the nuchal ligament ossification, the mean age of the 143 males was 51.1 and that of the 97 females was 48.0 years. It was not observed completely below teens, and was observed 1% in twenties, 6.1% in thirties, 18.6% in forties, and 26.3% over fifties. It was significantly prevalent in older age group (P<0.01) and in males than females among the same age group (P<0.05). The shapes of nuchal ligament ossification were as follows in order of frequency : rod-like (49.2%), round (30.4%), and segmented (20.4%). The highest involvement of ossification was found at the level of C5 (67.9%), C4 (29.2%), C6 (22.9%), C3 (3.3%), C7 (2.9%), C2 (0.8%), and C1 (0.4%). The nuchal ligament ossifications on lateral cephalometric radiographs were showed as round, rodlike, or segmented shape. The nuchal ligament ossification is often observed after the age of 40 and is observed more frequently in males than females. The highest shape of nuchal ligament ossification was rod-like shape and the highest involvement of cervical spine was C5.

  16. Design and characterization of a biodegradable composite scaffold for ligament tissue engineering.

    Science.gov (United States)

    Hayami, James W S; Surrao, Denver C; Waldman, Stephen D; Amsden, Brian G

    2010-03-15

    Herein we report on the development and characterization of a biodegradable composite scaffold for ligament tissue engineering based on the fundamental morphological features of the native ligament. An aligned fibrous component was used to mimic the fibrous collagen network and a hydrogel component to mimic the proteoglycan-water matrix of the ligament. The composite scaffold was constructed from cell-adherent, base-etched, electrospun poly(epsilon-caprolactone-co-D,L-lactide) (PCLDLLA) fibers embedded in a noncell-adherent photocrosslinked N-methacrylated glycol chitosan (MGC) hydrogel seeded with primary ligament fibroblasts. Base etching improved cellular adhesion to the PCLDLLA material. Cells within the MGC hydrogel remained viable (72 +/- 4%) during the 4-week culture period. Immunohistochemistry staining revealed ligament ECM markers collagen type I, collagen type III, and decorin organizing and accumulating along the PCLDLLA fibers within the composite scaffolds. On the basis of these results, it was determined that the composite scaffold design was a viable alternative to the current approaches used for ligament tissue engineering and merits further study. (c) 2009 Wiley Periodicals, Inc.

  17. Evaluation of the Performance of ClimGen and LARS-WG models in generating rainfall and temperature time series in rainfed research station of Sisab, Northern Khorasan

    Directory of Open Access Journals (Sweden)

    najmeh khalili

    2016-10-01

    Full Text Available Introduction:Many existing results on water and agriculture researches require long-term statistical climate data, while practically; the available collected data in synoptic stations are quite short. Therefore, the required daily climate data should be generated based on the limited available data. For this purpose, weather generators can be used to enlarge the data length. Among the common weather generators, two models are more common: LARS-WG and ClimGen. Different studies have shown that these two models have different results in different regions and climates. Therefore, the output results of these two methods should be validated based on the climate and weather conditions of the study region. Materials and Methods:The Sisab station is 35 KM away from Bojnord city in Northern Khorasan. This station was established in 1366 and afterwards, the meteorological data including precipitation data are regularly collected. Geographical coordination of this station is 37º 25׳ N and 57º 38׳ E, and the elevation is 1359 meter. The climate in this region is dry and cold under Emberge and semi-dry under Demarton Methods. In this research, LARG-WG model, version 5.5, and ClimGen model, version 4.4, were used to generate 500 data sample for precipitation and temperature time series. The performance of these two models, were evaluated using RMSE, MAE, and CD over the 30 years collected data and their corresponding generated data. Also, to compare the statistical similarity of the generated data with the collected data, t-student, F, and X2 tests were used. With these tests, the similarity of 16 statistical characteristics of the generated data and the collected data has been investigated in the level of confidence 95%. Results and Discussion:This study showed that LARS-WG model can better generate precipitation data in terms of statistical error criteria. RMSE and MAE for the generated data by LAR-WG were less than ClimGen model while the CD value of

  18. Functional regeneration of ligament-bone interface using a triphasic silk-based graft.

    Science.gov (United States)

    Li, Hongguo; Fan, Jiabing; Sun, Liguo; Liu, Xincheng; Cheng, Pengzhen; Fan, Hongbin

    2016-11-01

    The biodegradable silk-based scaffold with unique mechanical property and biocompatibility represents a favorable ligamentous graft for tissue-engineering anterior cruciate ligament (ACL) reconstruction. However, the low efficiency of ligament-bone interface restoration barriers the isotropic silk graft to common ACL therapeutics. To enhance the regeneration of the silk-mediated interface, we developed a specialized stratification approach implementing a sequential modification on isotropic silk to constitute a triphasic silk-based graft in which three regions respectively referring to ligament, cartilage and bone layers of interface were divided, followed by respective biomaterial coating. Furthermore, three types of cells including bone marrow mesenchymal stem cells (BMSCs), chondrocytes and osteoblasts were respectively seeded on the ligament, cartilage and bone region of the triphasic silk graft, and the cell/scaffold complex was rolled up as a multilayered graft mimicking the stratified structure of native ligament-bone interface. In vitro, the trilineage cells loaded on the triphasic silk scaffold revealed a high proliferative capacity as well as enhanced differentiation ability into their corresponding cell lineage. 24 weeks postoperatively after the construct was implanted to repair the ACL defect in rabbit model, the silk-based ligamentous graft exhibited the enhancement of osseointegration detected by a robust pullout force and formation of three-layered structure along with conspicuously corresponding matrix deposition via micro-CT and histological analysis. These findings potentially broaden the application of silk-based ligamentous graft for ACL reconstruction and further large animal study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. [Treatment of complete acromioclavicular joint dislocation with transfer of the medial half of the coracoacromial ligament to reconstruct the coracoclavicular ligament].

    Science.gov (United States)

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2015-04-01

    To explore the operation methods and clinical effects of transfer of the medial half of the coracoacromial ligament to reconstruct the coracoclavicular ligament in treating complete acromioclavicular joint dislocation. From January 2006 to June 2012,26 patients with acute complete acromioclavicular joint dislocation underwent surgery. Transfer of the medial half of the coracoacromial ligament to reconstruct the coracoclavicular ligament, additional clavical hoot plate and Kirschner wires fixation, were performed in all the patients. Among the patients, 18 patients were male and 8 patients were female, with an average age of 36.7 years old (ranged from 25 to 51 years). The duration from injury to operation was from 3 to 12 days with an average of 5 days. According to the Rockwood classification, 4 cases were grade III and 22 cases were grade V . Clinical manifestation included local swelling, tenderness with snapping, limitation of shoulder joint motion. In preoperative bilateral shoulder joint X-rays, the injured coracoclavicular distance was (16.2 ± 5.0) mm which was significantly wider than that of uninjured sides (7.6 ± 1.0) mm. Clinical results were evaluated according to X-rays and Constant-Murley score. All incisions obtained primary healing after operation without complication of infection, internal fixation breakage, redislocation. All the patients were followed up from 12 to 30 months with an average of 18 months. Kirschner wires and internal fixation plate were removed at 1 month and 8-10 months after operation, respectively. At final follow-up, the motion of shoulder joint recovered to normal and a no pain joint was obtained. According to Constant-Murley score, 24 cases got excellent results and 2 cases good. There was no significant difference after operation between the injured coracoclavicular distance and the uninjured contralateral side [(7.7 ± 1.2) mm vs (7.6 ± 1.0) mm), P > 0.05]. Transfer of the medial half of the coracoacromial ligament to

  20. Empirical Asset Pricing: Eugene Fama, Lars Peter Hansen, and Robert Shiller

    OpenAIRE

    Campbell, John Y.

    2016-01-01

    The Nobel Memorial Prize in Economic Sciences for 2013 was awarded to Eugene Fama, Lars Peter Hansen, and Robert Shiller for their contributions to the empirical study of asset pricing. Some observers have found it hard to understand the common elements of the laureates research, preferring to highlight areas of disagreement among them. This paper argues that empirical asset pricing is a coherent enterprise, which owes much to the laureates seminal contributions, and that important themes in ...

  1. Radio sterilized human ligaments and their clinical application;Ligamentos humanos radioesterilizados y su aplicacion clinica

    Energy Technology Data Exchange (ETDEWEB)

    Luna Z, D.; Reyes F, M. L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Diaz M, I.; Hernandez R, G., E-mail: daniel.luna@inin.gob.m [Centro Estatal de Trasplantes del Estado de Mexico, Pablo Sidar No. 602, Col. Universidad, 50130 Toluca, Estado de Mexico (Mexico)

    2009-10-15

    The ligaments are human tissues that are used in the transplantation area. A ligament is an anatomical structure in band form, composed by resistant fibers that connect the tissues that unite the bones with the articulations. In an articulation, the ligaments allow and facilitate the movement inside the natural anatomical directions, while it restricts those movements that are anatomically abnormal, impeding lesions that could arise of this type of movements. The kneecap ligament is a very important tissue in the knee mobility and of walking in the human beings. This ligament can injure it because of automobile accidents, for sport lesions or illnesses, and in many cases the only form of recovering the knee movement is carried out a transplant with the purpose of replacing the damage ligament by allo gen kneecap ligament processed in specialized Tissue Banks where the tissue is sterilized with gamma radiation of {sup 60}Co at very low temperatures, obtaining high quality ligaments for clinical application in injured patients. The kneecap ligaments are processed in the Tissue Banks with a segment of kneecap bone, a segment of tibial bone, the contained ligament between both bones and in some cases a fraction of the quadriceps tendon. In this work is given a description of the selection method of the tissue that includes the donor's serologic control, the kneecap ligament processing in the Radio Sterilized Tissues Bank, its sterilization with gamma radiation of {sup 60}Co, also it is indicated like the clinical application of the allo gen ligament was realized in a hasty patient and whose previous crossed ligament was injured. Finally the results are presented from the tissue obtaining until the clinical application of it is, and in this case is observed a favorable initial evolution of the transplantation patient. (Author)

  2. Biofabrication of soft tissue templates for engineering the bone-ligament interface.

    Science.gov (United States)

    Harris, Ella; Liu, Yurong; Cunniffe, Grainne; Morrissey, David; Carroll, Simon; Mulhall, Kevin; Kelly, Daniel J

    2017-10-01

    Regenerating damaged tissue interfaces remains a significant clinical challenge, requiring recapitulation of the structure, composition, and function of the native enthesis. In the ligament-to-bone interface, this region transitions from ligament to fibrocartilage, to calcified cartilage and then to bone. This gradation in tissue types facilitates the transfer of load between soft and hard structures while minimizing stress concentrations at the interface. Previous attempts to engineer the ligament-bone interface have utilized various scaffold materials with an array of various cell types and/or biological cues. The primary goal of this study was to engineer a multiphased construct mimicking the ligament-bone interface by driving differentiation of a single population of mesenchymal stem cells (MSCs), seeded within blended fibrin-alginate hydrogels, down an endochondral, fibrocartilaginous, or ligamentous pathway through spatial presentation of growth factors along the length of the construct within a custom-developed, dual-chamber culture system. MSCs within these engineered constructs demonstrated spatially distinct regions of differentiation, adopting either a cartilaginous or ligamentous phenotype depending on their local environment. Furthermore, there was also evidence of spatially defined progression toward an endochondral phenotype when chondrogenically primed MSCs within this construct were additionally exposed to hypertrophic cues. The study demonstrates the feasibility of engineering spatially complex soft tissues within a single MSC laden hydrogel through the defined presentation of biochemical cues. This novel approach represents a new strategy for engineering the ligament-bone interface. Biotechnol. Bioeng. 2017;114: 2400-2411. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Alar ligaments: radiological aspects in the diagnosis of patients with whiplash injuries

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Biederer, J.; Jahnke, Th.; Grimm, J.; Heller, M.

    2002-01-01

    Post-traumatic changes of the alar ligaments have been proposed to be the cause of chronic pain in patients after whiplash injury of the cervical spine. In addition to an asymmetric dens position, widening of the atlantodental distance to more than 12 mm can be an indirect sign of an alar ligament rupture. CT is recommended for detection of a avulsion fracture of the occipital condyle. Isolated ruptures of the alar ligaments are best visualized on MRI. In patients with chronic impairments after whiplash injuries changes of the alar ligaments on MRI must be differentiated from normal variants in healthy individuals. (orig.) [de

  4. Lise 1 Biyoloji Dersi Alan Öğrencilerin Canlıların Çeşitliliği ve Sınıflandırılmasıyla ilgili Kavram Yanılgılarının Belirlenmesi ve Kavram Haritası Yardımıyla Değiştirilmesi

    OpenAIRE

    TÜRKMEN, Lütfullah; ÇARDAK, Osman; DIKMENLI, Musa

    2014-01-01

    İlk ve orta öğrenim fen bilimleri eğitiminde, öğrencilerin sahip oldukları kavram yanılgılarını değiştirmek için öğretmenler ve fen bilimleri eğitimcileri tarafından farklı öğretim yöntemleri kullanılmaktadır. Kavram yanılgılarını değiştirmek kullanılan en yaygın olan yöntemlerden biri de kavram haritalarıdır. Bu çalışmanın amacı Lise 1. sınıf biyoloji dersi alan öğrencilerin Canlıların çeşitliliği ve sınıflandırılması hakkındaki kavram yanılgılarını değiştirmektir. Bu çalışma biyoloji dersi...

  5. Altındere Vadisi Milli Parkı kullanıcılarının rekreasyonel memnuniyetinin belirlenmesi

    Directory of Open Access Journals (Sweden)

    Özge Volkan AKSU

    2017-07-01

    Full Text Available Bu çalışma; Altındere Vadisi Milli Parkı kullanıcılarının rekreasyonel memnuniyetinin belirlenmesi amacı ile 2015 yılı yaz dönemi milli park alanında, 308 yerli kullanıcı ile yapılan anket çalışmalarını kapsamaktadır. Anket soruları ile kullanıcılarının bazı kişisel özellikleri, kullanım tercihleri, katıldıkları rekreasyonel etkinlikler, geliş amaçları, alan tercihleri, genel ve beklenen memnuniyetleri, alan farkındalığı, kullanıcı memnuniyet ve memnuniyetsizlik durumunu etkileyen faktörler ve bu faktörlerle kullanıcıların bazı kişisel özellikleri arasındaki ilişkiler istatistiksel yöntemlerle irdelenmiştir. Sonuç olarak; “milli parkın doğal ve kültürel peyzaj değerleri, görsel kalite”, “alandan aktif olarak yararlanma isteği”, “alandan pasif olarak yararlanma isteği”, “macera ve kendini keşfetme”, “açık hava aktivite olanakları”, “sosyalleşme”,  “ulaşılabilirlik ve alan kullanımı” olarak tanımlanabilecek faktörlerin alandaki kullanıcı memnuniyeti üzerinde etkili olduğu, yine; “planlama-tasarım sorunları”, “donatı elemanı eksikliği, yönetim”, “taşıma kapasitesinin aşılması-kalabalık, gürültü kirliliği”, “çevre-görüntü kirliliği, alt yapı-bakım eksikliği”, “bilgi eksikliği ve yönetim” olarak tanımlanabilecek faktörlerin ise kullanıcı memnuniyetsizliği üzerinde etkili olduğu belirlenmiştir. Kullanıcıların genel memnuniyet ve beklentilerinin karşılanma durumu orta düzeydir. Kullanıcıların memnuniyet faktörlerinin, geldiği yerin milli parka uzaklığı ve eğitim, memnuniyetsizlik faktörlerinin ise geldiği yerin milli parka uzaklığı, cinsiyet ve yaş olarak belirlenen etmenlerden etkilendiği saptanmıştır.

  6. Arthrographic differential diagnosis between ruptures of the anterior talofibular ligament, the joint capsule and the anterior tibiofibular ligament

    International Nuclear Information System (INIS)

    Moppes, F.I. van; Hoogenband, C.R. van den; Meijer, F.

    1980-01-01

    Aus einem Studium der Literatur, chirurgischen Befunden und Untersuchungen an Leichen kann es als unwahrscheinlich angesehen werden, dass bei einer Fussverstauchung vom Inversionstyp ein Riss des vorderen tibiofibularen Ligraments haeufig zusammen mit einem Gelenkkapselriss und einem seitlichen Baenderriss auftritt. Entgegen der Beobachtung anderer Verfasser fanden wir, dass ein Riss des vorderen tibiofularen Ligaments in keiner Weise aus dem Vorhandensein oder Nichtvorhandensein folgender arthrographischer Befunde geschlossen werden konnte: a) kontrastfreie Zone, b) tibiofibularer Rezessus, oder c) beide zusammen. Ein Gelenkkapselriss kann angenommen werden, wenn Kontrastmittel aus dem Gelenk in das weiche Gewebe austritt, ohne unterhalb oder seitlich in den Aussenknoechel zu dringen. Ein Austritt des Kontrastmittels unterhalb und seitlich des Aussenknoechels deutet auf einen Riss des vorderen tabofibularen Ligaments hin. Die anatomischen Zusammenhaenge zwischen Bandverbindung, Gelenkkapsel, tibiofibularem Rezessus und dem vorderen talofibularen Ligament wurden an Leichen und waehrend der chirurgischen Eingriffe studiert. Ausbreitung des Kontrastmittels im weichen Gewebe wird wahrscheinlich bestimmt durch die Anordnung und Beschaedigung der Weichteile und durch die Groesse des entstandenen Haematoms und folgt dem Weg des kleinsten Widerstandes. (orig.) [de

  7. Knee Ligament Injury and the Clinical Application of Tissue Engineering Techniques: A Systematic Review.

    Science.gov (United States)

    Riley, Thomas C; Mafi, Reza; Mafi, Pouya; Khan, Wasim S

    2018-02-23

    The incidence of knee ligament injury is increasing and represents a significant cost to healthcare providers. Current interventions include tissue grafts, suture repair and non-surgical management. These techniques have demonstrated good patient outcomes but have been associated graft rejection, infection, long term immobilization and reduced joint function. The limitations of traditional management strategies have prompted research into tissue engineering of knee ligaments. This paper aims to evaluate whether tissue engineering of knee ligaments offers a viable alternative in the clinical management of knee ligament injuries. A search of existing literature was performed using OVID Medline, Embase, AMED, PubMed and Google Scholar, and a manual review of citations identified within these papers. Silk, polymer and extracellular matrix based scaffolds can all improve graft healing and collagen production. Fibroblasts and stem cells demonstrate compatibility with scaffolds, and have been shown to increase organized collagen production. These effects can be augmented using growth factors and extracellular matrix derivatives. Animal studies have shown tissue engineered ligaments can provide the biomechanical characteristics required for effective treatment of knee ligament injuries. There is a growing clinical demand for a tissue engineered alternative to traditional management strategies. Currently, there is limited consensus regarding material selection for use in tissue engineered ligaments. Further research is required to optimize tissue engineered ligament production before clinical application. Controlled clinical trials comparing the use of tissue engineered ligaments and traditional management in patients with knee ligament injury could determine whether they can provide a cost-effective alternative. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Labores, quitutes e panelas: em busca do lar ideal

    OpenAIRE

    Pilla,Maria Cecília Barreto Amorim

    2008-01-01

    A partir do conceito de auto-governo, entendido como um modelo psicológico capaz de garantir o reconhecimento e respeito do próximo, uma valorização de si mesmo, este artigo propõe uma reflexão a respeito da mulher no desempenho do papel de "rainha do lar" no Brasil do início do século XX. Na preparação da casa repousava a valorização de uma conduta controlada da dona-de-casa, que deveria manter o controle sobre tudo e sobre todos, tendo aí a oportunidade de demonstrar sua capacidade de gover...

  9. Late rupture of the posterior cruciate ligament after total knee replacement.

    OpenAIRE

    Montgomery, R. L.; Goodman, S. B.; Csongradi, J.

    1993-01-01

    To our knowledge there have been no reports of late rupture of the posterior cruciate ligament (PCL) as a cause of instability in PCL-retaining total knee prostheses. In our experience of 150 total knee replacements using PCL-retaining prosthesis, three cases (2.0%) of late rupture of the posterior cruciate ligament have occurred, each leading to chronic instability, disabling pain, and revision arthroplasty. In each case rupture of the posterior cruciate ligament was confirmed at the time of...

  10. The Influence of Interleukin-4 on Ligament Healing

    Science.gov (United States)

    Chamberlain, Connie S; Leiferman, Ellen M; Frisch, Kayt E; Wang, Sijian; Yang, Xipei; Brickson, Stacey L; Vanderby, Ray

    2011-01-01

    Despite a complex cascade of cellular events to reconstruct the damaged extracellular matrix, ligament healing results in a mechanically inferior scarred ligament. During normal healing, granulation tissue expands into any residual normal ligamentous tissue (creeping substitution), resulting in a larger region of healing, greater mechanical compromise, and an inefficient repair process. To control creeping substitution and possibly enhance the repair process, the anti-inflammatory cytokine, interleukin-4 (IL-4) was administered to rats prior to and after rupture of their medial collateral ligaments. In vitro experiments demonstrated a time-dependent effect on fibroblast proliferation after interleukin-4 treatment. In vivo treatments with interleukin-4 (100 ng/ml i.v.) for 5 days resulted in decreased wound size and type III collagen and increased type I procollagen, indicating a more regenerative early healing in response to the interleukin-4 treatment. However, continued treatment of interleukin-4 to day 11 antagonized this early benefit and slowed healing. Together, these results suggest that interleukin-4 influences the macrophages and T-lymphocytes but also stimulates fibroblasts associated with the proliferative phase of healing in a dose-, cell-, and time-dependent manner. Although treatment significantly influenced healing in the first week after injury, interleukin-4 alone was unable to maintain this early regenerative response. PMID:21518087

  11. Operation of bare HPGe detectors in LAr/LN{sub 2} for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Heider, M Barnabe; Chkvorets, O; Schoenert, S [MPI fuer Kernphysik, Heidelberg (Germany); Cattadori, C [INFN-Milano Bicocca, Milano (Italy); Vacri, A di [INFN-LNGS, L' Aquila (Italy); Gusev, K; Shirchenko, M [Russian Research Center Kurchatov Institute, Moscow, Russia and JINR, Dubna (Russian Federation)], E-mail: assunta.divacri@lngs.infn.it

    2008-11-01

    GERDA is designed to search for 0{nu}{beta}{beta}-decay of {sup 76}Ge using high purity germanium detectors (HPGe), enriched ({approx} 85%) in {sup 76}Ge, directly immersed in LAr which acts both as shield against {gamma} radiation and as cooling medium. The cryostat is located in a stainless steel water tank providing an additional shield against external background. The GERDA experiment aims at a background (b) {approx}<10{sup -3} cts/(kg-y-keV) and energy resolution (FWHM) {<=} 4 keV at Q{sub {beta}}{sub {beta}} = 2039 keV. GERDA experiment is foreseen to proceed in two phases. For Phase I, eight reprocessed enriched HPGe detectors from the past HdM [C Balysh et al., Phys. Rev. D 66 (1997) 54] and IGEX [C E Aalseth et al., Phys. of Atomic Nuclei 63 (2000) 1225] experiments ({approx} 18 kg) and six reprocessed natural HPGe detectors ({approx} 15 kg) from the Genius Test-Facility [H V Klapdor et al., HIM A 481 (2002) 149] will be deployed in strings. GERDA aims at b {approx}< 10{sup -2} cts/(kg{center_dot}keV{center_dot}y). With an exposure of {approx} 15 kg{center_dot}y of {sup 76}Ge and resolution {approx} 3.6 keV, the sensitivity on the half-life will be T{sup 0{nu}}{sub 1/2} 3 {center_dot} 10{sup 25} y (90 % C.L.) corresponding to m{sub ee} < 270 meV [V A Rodin et al., Nucl. Phys. A 766 (2006) 107]. In Phase II, new diodes, able to discriminate between single- and multi-site events, will be added ({approx} 20 kg of {sup 76}Ge with intrinsic b {approx} 10{sup -2} cts/(kg{center_dot}keV{center_dot}y). With an exposure of {approx} 120 kg{center_dot}y, it is expected T{sup 0{nu}}{sub 1/2} > 1.5 {center_dot} 10{sup 26} y (90% C.L.) corresponding to m{sub ee} < 110 meV [V A Rodin et al., Nucl. Phys. A 766 (2006) 107]. Three natural p-type HPGe prototypes (different passivation layer designs) are available in the GERDA underground facility at LNGS to investigate the effect of the detector assembly (low-mass low-activity holder), of the handling procedure and of the

  12. Digital Natives, Social Networks and the Future of Libraries Dijital Yerliler, Sosyal Ağlar ve Kütüphanelerin Geleceği

    Directory of Open Access Journals (Sweden)

    Yaşar Tonta

    2009-12-01

    Full Text Available Facebook, MySpace, Flickr and YouTube are currently among the most frequently visited websites with Web 2.0 features. They are used not only for social networking and entertainment but also for access to information, for learning and for carrying out professional work. Social networks commonly have Web 2.0 features, offer personalized services and allow users to incorporate their own content easily and describe, organize and share it with others, thereby enriching users’ experience. Some users tend to “live” on those social networks and expect information providing organizations to offer similar services. They want libraries to be as accessible, flexible, open to collaboration and sharing as that of social networks and heighten the expectations from such institutions. The future of libraries is closely associated with how successfully they meet the demands of digital users. Otherwise, the “net generation” or the “digital natives” grown up with the Web, Google and Facebook would see libraries as outdated institutions and “take their business elsewhere” to satisfy their information needs. In this paper, the impact of the technological convergence on information providing organizations is reviewed and the challenges and opportunities facing libraries in the digital environment are discussed. Facebook, MySpace, Flickr ve YouTube gibi Web 2.0 özelliklerine sahip sosyal ağlar en çok ziyaret edilen web siteleri arasında yer almaktadır. Sosyal ağlar sadece sosyalleşmek ve eğlenmek amacıyla değil, bilgiye erişmek, öğrenmek ve profesyonel iş yapmak amacıyla da kullanılmaktadır. Sosyal ağların sağladığı işbirliği, kişiselleştirme, kullanıcı destekli içerik ekleme ve üst veri gibi özellikler kullanıcı deneyimini zenginleştirmekte ve bu web sitelerini daha çekici kılmaktadır. Kütüphanelerin de sosyal ağlar kadar erişilebilir, esnek, işbirliği ve paylaşıma açık olmasını bekleyen kullanıcılar

  13. A Nano-indentation Identification Technique for Viscoelastic Constitutive Characteristics of Periodontal Ligaments

    Directory of Open Access Journals (Sweden)

    Ashrafi H.

    2016-06-01

    Full Text Available Introduction: Nano-indentation has recently been employed as a powerful tool for determining the mechanical properties of biological tissues on nano and micro scales. A majority of soft biological tissues such as ligaments and tendons exhibit viscoelastic or time-dependent behaviors. The constitutive characterization of soft tissues is among very important subjects in clinical medicine and especially, biomechanics fields. Periodontal ligament plays an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. It is also the most accessible ligament in human body as it can be directly manipulated without any surgical intervention. From a mechanical point of view, this ligament can be considered as a thin interface made by a solid phase, consisting mainly of collagen fibers, which is immersed into a so-called ground substance. However, the viscoelastic constitutive effects of biological tissues are seldom considered rigorous during Nano-indentation tests. Methods: In the present paper, a mathematical contact approach is developed to enable determining creep compliance and relaxation modulus of distinct periodontal ligaments, using constant–rate indentation and loading time histories, respectively. An adequate curve-fitting method is presented to determine these characteristics based on the Nano-indentation of rigid Berkovich tips. Generalized Voigt-Kelvin and Wiechert models are used to model constitutive equations of periodontal ligaments, in which the relaxation and creep functions are represented by series of decaying exponential functions of time. Results: Time-dependent creep compliance and relaxation function have been obtained for tissue specimens of periodontal ligaments. Conclusion: To improve accuracy, relaxation and creep moduli are measured from two tests separately. Stress relaxation effects appear more rapidly than creep in the periodontal ligaments.

  14. Meniscofibular Ligament: Morphology and Functional Significance of a Relatively Unknown Anatomical Structure

    Directory of Open Access Journals (Sweden)

    K. Natsis

    2012-01-01

    Full Text Available Purpose. A relatively unknown ligamentous structure of the posterolateral corner of the knee joint, the so-called meniscofibular ligament (MFL, was investigated as regards its macroscopic morphology, its histological features, and its reaction to knee movements. Material and Methods. MFL was exposed on 21 fresh-frozen unpaired knee joints. Its microscopic morphology was examined utilizing for comparison the fibular collateral and the popliteofibular ligament. Results. MFL was encountered in 100% of the specimens as a thin striplike fibrous band extending between the lower border of the lateral meniscus and the head of the fibula. MFL was tense during knee extension and external rotation of the tibia, whereas its histological features were similar to those of fibular collateral and popliteofibular ligament. Discussion. Its precise histological nature is studied as well as its tension alterations during knee movements. The potential functional significance of the MFL with respect to its role in avoidance of lateral meniscus and lateral coronary ligament tears is discussed. Conclusions. MFL presumably provides an additional protection to the lateral meniscus during the last stages of knee extension, as well as to the lateral coronary ligament reducing the possibility of a potential rupture.

  15. Bir grup üniversite öğrencisinin batıl inanışlar ve hastalıklara karşı tutum ve davranışlarının değerlendirilmesi

    OpenAIRE

    Ögenler, Oya; Yapıcı, Gülçin

    2011-01-01

    Özet Amaç. Tıp, batıl ve dini inançlar belli bir toplumda sözlü veya yazılı bir şekilde nesilden nesile aktarılır. Tıp, batıl inançlar ve din birbirinden bazen kesin çizgilerle ayrılırken bazen aralarındaki sınır belirsizleşebilmektedir. Bu üçlüden herhangi birine ait davranışa neden olan bilgi zamanla değişime uğrar başlangıç noktası unutulur ama varlığını sürdürür. Doğru oldukları için değil, işe yaradıkları için doğru kabul edilen birçok inanış insanları belirsizlikten kurtarır, iç rahatla...

  16. Arthroscopic suture anchor repair of the lateral ligament ankle complex: a cadaveric study.

    Science.gov (United States)

    Giza, Eric; Shin, Edward C; Wong, Stephanie E; Acevedo, Jorge I; Mangone, Peter G; Olson, Kirstina; Anderson, Matthew J

    2013-11-01

    Operative treatment of mechanical ankle instability is indicated for patients with multiple sprains and continued episodes of instability. Open repair of the lateral ankle ligaments involves exposure of the attenuated ligaments and advancement back to their anatomic insertions on the fibula using bone tunnels or suture implants. Open and arthroscopic fixation are equal in strength to failure for anatomic Broström repair. Controlled laboratory study. Seven matched pairs of human cadaveric ankle specimens were randomized into 2 groups of anatomic Broström repair: open or arthroscopic. The calcaneofibular ligament and anterior talofibular ligament were excised from their origin on the fibula. In the open repair group, 2 suture anchors were used to reattach the ligaments to their anatomic origins. In the arthroscopic repair group, identical suture anchors were used for repair via an arthroscopic technique. The ligaments were cyclically loaded 20 times and then tested to failure. Torque to failure, degrees to failure, initial stiffness, and working stiffness were measured. A matched-pair analysis was performed. Power analysis of 0.8 demonstrated that 7 pairs needed to show a difference of 30%, with a 15% standard error at a significance level of α = .05. There was no difference in the degrees to failure, torque to failure, or stiffness for the repaired ligament complex. Nine of 14 specimens failed at the suture anchor. There is no statistical difference in strength or stiffness of a traditional open repair as compared with an arthroscopic anatomic repair of the lateral ligaments of the ankle. An arthroscopic technique can be considered for lateral ligament stabilization in patients with mild to moderate mechanical instability.

  17. Biomechanical and histologic evaluation of tissue engineered ligaments using chitosan and hyaluronan hybrid polymer fibers: a rabbit medial collateral ligament reconstruction model.

    Science.gov (United States)

    Irie, Toru; Majima, Tokifumi; Sawaguchi, Naohiro; Funakoshi, Tadanao; Nishimura, Shin-Ichiro; Minami, Akio

    2011-05-01

    In this study, we used a rabbit medial collateral ligament reconstruction model to evaluate a novel chitosan-based hyaluronan hybrid polymer fiber scaffold for ligament tissue engineering and to examine whether mechanical forces exerted in an in vivo model increased extracellular matrix production by seeded fibroblasts. Scaffolds were used 2 weeks after incubation with fibroblasts obtained from the same rabbit in a cell-seeded scaffold (CSS) group and without cells in a noncell-seeded scaffold (NCSS) group. At 3, 6, and 12 weeks after surgery, the failure loads of the engineered ligaments in the CSS groups were significantly greater than those in the NCSS groups. At 6 weeks after surgery, the reconstructed tissue of the CSS group was positive for type I collagen, whereas that in the NCSS group was negative for type I collagen. At 12 weeks after surgery, the reconstructed tissue stained positive for type I collagen in the CSS group, but negative in the NCSS group. Our results indicate that the scaffold material enhanced the production of type I collagen and led to improved mechanical strength in the engineered ligament in vivo. Copyright © 2011 Wiley Periodicals, Inc.

  18. DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

    Science.gov (United States)

    Aalseth, C. E.; Acerbi, F.; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Antonioli, P.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Asner, D. M.; Ave, M.; Back, H. O.; Barrado Olmedo, A. I.; Batignani, G.; Bertoldo, E.; Bettarini, S.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Boulay, M.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Castellani, A.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Colocci, M.; Corgiolu, S.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Da Rocha Rolo, M. D.; Daniel, M.; Davini, S.; de Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Della Valle, M.; Demontis, P.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Dolgov, A.; Dormia, I.; Dussoni, S.; Empl, A.; Fernandez Diaz, M.; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garcia Abia, P.; Gendotti, A.; Ghisi, A.; Giagu, S.; Giampa, P.; Gibertoni, G.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, An.; Jillings, C.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kim, S.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; Kuźniak, M.; La Commara, M.; Lehnert, B.; Li, X.; Lissia, M.; Lodi, G. U.; Loer, B.; Longo, G.; Loverre, P.; Lussana, R.; Luzzi, L.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Martoff, C. J.; Mascia, M.; Mayer, M.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Monte, A.; Morrocchi, M.; Mount, B. J.; Mu, W.; Muratova, V. N.; Murphy, S.; Musico, P.; Nania, R.; Navrer Agasson, A.; Nikulin, I.; Nosov, V.; Nozdrina, A. O.; Nurakhov, N. N.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pelczar, K.; Pellegrini, L. A.; Pelliccia, N.; Perotti, F.; Perruzza, R.; Pesudo, V.; Piemonte, C.; Pilo, F.; Pocar, A.; Pollmann, T.; Portaluppi, D.; Pugachev, D. A.; Qian, H.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Retière, F.; Riffard, Q.; Rivetti, A.; Rizzardini, S.; Romani, A.; Romero, L.; Rossi, B.; Rossi, N.; Rubbia, A.; Sablone, D.; Salatino, P.; Samoylov, O.; Sánchez García, E.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Shekhtman, L.; Shemyakina, E.; Sheshukov, A.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Speziale, F.; Stainforth, R.; Stanford, C.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Tosi, A.; Trinchese, P.; Unzhakov, E. V.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Villa, F.; Vishneva, A.; Vogelaar, B.; Wada, M.; Wahl, J.; Walding, J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Williams, R.; Wojcik, M. M.; Wu, S.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Yllera de Llano, A.; Zappa, F.; Zappalà, G.; Zhu, C.; Zichichi, A.; Zullo, M.; Zullo, A.; Zuzel, G.

    2018-03-01

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of >3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ν-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2 × 10^{-47} cm2 (1.1 × 10^{-46} cm2) for WIMPs of 1 TeV/c 2 (10 TeV/c 2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

  19. Kinematics of the lateral ligamentous constraints of the elbow joint

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole; Dalstra, Michel

    1996-01-01

    preventer of elbow joint laxity. The LCLC was observed to be a complex structure of ligamentous fibers rather than discreet bands. The LCLC forms a ligamentous constraint between the lateral humeral epicondyle and the ulna, stabilizing the elbow joint and forming a base for radial head stability...

  20. Magnetic resonance imaging evaluation of cruciate ligaments after arthroscopic reconstruction

    Directory of Open Access Journals (Sweden)

    Amit Kharat

    2017-01-01

    Full Text Available Background: Due to increase in road traffic and sports injuries, tears of anterior cruciate ligament (ACL and the posterior cruciate ligament (PCL of the knee are common. Magnetic resonance imaging (MRI is emerging as an important tool of diagnosis and evaluation of these injuries. Methods: We carried out a prospective study on role of MRI on ten patients who had undergone ACL or PCL repair over a period of six months. In this report we present three illustrative cases to capture the spectrum of findings in our series to underline the role of MRI in management of such injuries and discuss the modalities of the procedure. Results: In our series, as demonstrated by the cases, MRI had an important role in diagnosis and evaluation of injuries to the cruciate ligaments. Conclusion: MRI can play an important role, particularly in tertiary centres, in diagnosis and evaluation of reconstructed ACL and PCL ligaments of the knee joint.

  1. The name cranial ovarian suspensory ligaments in mammalian anatomy should be used only to indicate the structures derived from the foetal cranial mesonephric and gonadal ligaments

    NARCIS (Netherlands)

    P. van der Schoot (P.)

    1993-01-01

    textabstractThe term ovarian suspensory ligament appears ambiguous when human adult anatomy textbooks are compared with human embryology or with general mammalian anatomy textbooks. The term ovarian suspensory ligament in laboratory rodents and domestic animals indicates homologous structures during

  2. Visibility of Anterolateral Ligament Tears in Anterior Cruciate Ligament-Deficient Knees With Standard 1.5-Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Hartigan, David E; Carroll, Kevin W; Kosarek, Frank J; Piasecki, Dana P; Fleischli, James F; D'Alessandro, Donald F

    2016-10-01

    To attempt to visualize the ligament with standard 1.5-tesla magnetic resonance imaging (MRI) in the acute anterior cruciate ligament (ACL)-torn knee, and if it is visible, attempt to characterize it as torn or intact at its femoral, meniscal, and tibial attachment sites. This was a retrospective MRI study based on arthroscopic findings of a known ACL tear in 72 patients between the years 2006 and 2010. Patients all had hamstring ACL reconstructions, no concomitant lateral collateral ligament, or posterolateral corner injury based on imaging and physical examination, and had a preoperative 1.5-tesla MRI scan with standard sequences performed within 3 weeks of the injury. Two fellowship-trained musculoskeletal radiologists retrospectively reviewed the preoperative MRI for visualization of the anterolateral ligament (ALL) for concomitant tears. Inter- and intraobserver reliability was calculated. Learning effect was analyzed to determine if radiologists' agreement improved as reads progressed. Both radiologists were able to visualize the ALL in 100% of the scans. Overall, ALL tears were noted in 26% by radiologist 1 and in 62% by radiologist 2. The agreement between the ligament being torn or not had a kappa of 0.54 between radiologists. The agreements in torn or not torn between radiologists in the femoral, meniscal, and tibial sites were 0.14, 0.15, and 0.31. The intraobserver reliability by radiologist 1 for femoral, meniscal, and tibial tears was 0.04, 0.57, and 0.54 respectively. For radiologist 2, they were 0.75, 0.61, and 0.55. There was no learning effect noted. ALL tears are currently unable to be reliably identified as torn or intact on standard 1.5-tesla MRI sequences. Proper imaging sequences are of crucial importance to reliably follow these tears to determine their clinical significance. Level IV, therapeutic case series study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Bilateral agenesis of the anterior cruciate ligament: MRI evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bedoya, Maria A.; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Radiology Department, Philadelphia, PA (United States); McGraw, Michael H. [Hospitalof theUniversityof Pennsylvania, Divisionof Orthopaedics, Philadelphia, PA (United States); Wells, Lawrence [The Children' s Hospital of Philadelphia, Division of Orthopaedics, Philadelphia, PA (United States)

    2014-09-15

    Bilateral agenesis of the anterior cruciate ligament (ACL) is extremely rare. We describe a 13-year-old girl who presented with bilateral knee pain without history of trauma; she has two family members with knee instability. Magnetic resonance imaging showed bilateral absence of the ACL, and medial posterior horn meniscal tears. Bilateral arthroscopic partial meniscectomy and anterior cruciate ligament reconstruction was performed. (orig.)

  4. Anatomy and Histology of the Knee Anterolateral Ligament.

    Science.gov (United States)

    Helito, Camilo Partezani; Demange, Marco Kawamura; Bonadio, Marcelo Batista; Tírico, Luis Eduardo Passarelli; Gobbi, Riccardo Gomes; Pécora, José Ricardo; Camanho, Gilberto Luis

    2013-12-01

    Reconstruction of the anterior cruciate ligament (ACL) is one of the most common procedures in orthopaedic surgery. However, even with advances in surgical techniques and implants, some patients still have residual anterolateral rotatory laxity after reconstruction. A thorough study of the anatomy of the anterolateral region of the knee is needed. To study the anterolateral region and determine the measurements and points of attachments of the anterolateral ligament (ALL). Descriptive laboratory study. Dissections of the anterolateral structures of the knee were performed in 20 human cadavers. After isolating the ALL, its length, thickness, width, and points of attachments were determined. The femoral attachment of the ALL was based on the anterior-posterior and proximal-distal distances from the attachment of the lateral collateral ligament (LCL). The tibial attachment point was based on the distance from the Gerdy tubercle to the fibular head and the distance from the lateral tibial plateau. The ligaments from the first 10 dissections were sent for histological analysis. The ALL was found in all 20 knees. The femoral attachment of the ALL at the lateral epicondyle averaged 3.5 mm distal and 2.2 mm anterior to the attachment of the LCL. Two distal attachments were observed: one inserts into the lateral meniscus, the other between the Gerdy tubercle and the fibular head, approximately 4.4 mm distal to the tibial articular cartilage. The mean measurements for the ligament were 37.3 mm (length), 7.4 mm (width), and 2.7 mm (thickness). The histological analysis of the ligaments revealed dense connective tissue. The ALL is consistently present in the anterolateral region of the knee. Its attachment to the femur is anterior and distal to the attachment of the LCL. Moving distally, it bifurcates at close to half of its length. The ALL features 2 distal attachments, one at the lateral meniscus and the other between the Gerdy tubercle and the fibular head. The ALL may be

  5. Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Adams, C.; et al.

    2018-04-07

    The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

  6. Background reduction at low energies with BEGe detector operated in liquid argon using the GERDA-LArGe facility

    Energy Technology Data Exchange (ETDEWEB)

    Budjas, Dusan [Physik-Department E15, Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    LArGe is a low background test facility used for proving innovative approaches to background reduction in support of the neutrinoless double beta decay experiment Gerda. These approaches include an anti-Compton veto using scintillation light detection from liquid argon, as well as a novel pulse shape discrimination method exploiting the characteristic electrical field distribution inside BEGe detectors. The latter technique can identify single-site events (typical for double beta decays) and efficiently reject multi-site events (typical for backgrounds from gamma-ray interactions), as well as different types of background events from detector surfaces. While the main focus of the LArGe facility is to assist with reaching the goal of Gerda - improving the sensitivity for {sup 76}Ge neutrinoless double beta decay search, reducing the background at low energies and lowering the energy threshold is also of interest. In particular such efforts can be potentially relevant for search of dark matter or low energy neutrino interactions. In this talk I present the experimental measurement of the low energy region with a BEGe detector operated in LArGe with the application of powerful background suppression methods. The performance will be compared to that of some dedicated dark matter detection experiments.

  7. Outcome of hamstring ligament harvest for Anterior Cruciate Ligament reconstruction with allograft versus autograft: a clinical trial

    Directory of Open Access Journals (Sweden)

    Mehdi Moghtadaei

    2013-11-01

    Full Text Available Background: The goal of this study was to evaluate, functional capacity of the knee in flexion and internal rotation after hamstring ligament harvest for Anterior Cruciate Ligament (ACL reconstruction.Methods: Fifty patients (male and 18-45 years old with isolated ACL injury, randomly allocated in two equal groups (in one group, ACL reconstruction was performed with Tibialis Posterior allograft and in another group with quadruple hamstring ligament auto graft and before and 6 months after surgery in both groups isokinetic flexion strength and isometric internal rotation strength of knee evaluated with Biodex System 4 dynamometer and rotational torque recorder, in order. Isokinetic flexion strength evaluated in sitting and prone position; the later position was performed for deep flexion strength evaluation. Also subjective and objective assessment of all patients pre operatively and 6 months post operatively was documented with International Knee Documentation Committee (IKDC questionnaire. In this study for first time, rotational torque strength of knee was recorded with new design measure, from isometric aspect and not isokinetic.Results: Although significant improvements in IKDC scores, flexion and internal rotation capacity of the knee were observed in both groups, post operatively in respect to pre operatively; there was no significant difference between 2 groups. (P<0.05 or more than 95% confidence Interval of the differenceConclusion: This study demonstrates that ACL reconstruction surgery, improves knee performance in flexion and internal rotation, regardless of hamstring tendon harvesting. Considering potential complications of allograft (for example: transfer of harmful diseases from donor to recipient, it is logical to use hamstring auto graft ligament for ACL reconstruction surgery. Because result of this study is not longstanding follow up and limited to male sex, for more worthfull conclusion, we suggest future study in both sex

  8. Roentgenologic diagnostics of capsular ligament lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, C.J.; Jaeger, M.

    1981-10-01

    The X-ray diagnostic is of obvious importance and relevance in the detection of acute or old capsular ligament lesions of the limb joint. On the one hand it serves as the plain radiograph (roentgenogram without contrast medium) for the assessment of osseous secondary lesions, for the documentation of luxationary positions of the joint partners, and in old capsular ligament lesions for the detection of an already existing arthrosis. On the other hand the X-ray images are of main importance, which are made from the hand-held limb in order to permit a comparison of the two sides, and which beyond the clinical detection of a joint instability indicate the extent and the direction of this instability and which also document it, and which allow in adolescents to recognize a separation of the epiphysis as an alternative to the capsular ligament rupture. Only in particular cases arthrography can provide some additional information, so for example in the case of an isolated syndesmosis rupture, ruptures of the rosette of the rotator muscle or of a damaged triangular disk in the hand. Angiography is only required in cases of traumatic luxations of the knee in order to exclude an intimal lesion of the popliteal artery.

  9. Anterior cruciate ligament ganglion: case report

    Directory of Open Access Journals (Sweden)

    André Pedrinelli

    Full Text Available CONTEXT: A ganglion is a cystic formation close to joints or tendinous sheaths, frequently found in the wrist, foot or knee. Intra-articular ganglia of the knee are rare, and most of them are located in the anterior cruciate ligament. The clinical picture for these ganglia comprises pain and movement restrictions in the knee, causing significant impairment to the patient. Symptoms are non-specific, and anterior cruciate ligament ganglia are usually diagnosed through magnetic resonance imaging or arthroscopy. Not all ganglia diagnosed through magnetic resonance imaging need to undergo surgical treatment: only those that cause clinical signs and symptoms do. Surgical results are considered good or excellent in the vast majority of cases. CASE REPORT: A 29-year-old male presented with pain in the left knee during a marathon race. Physical examination revealed limitation in the maximum range of knee extension and pain in the posterior aspect of the left knee. Radiographs of the left knee were normal, but magnetic resonance imaging revealed a multi-lobed cystic structure adjacent to the anterior cruciate ligament, which resembled a ganglion cyst. The mass was removed through arthroscopy, and pathological examination revealed a synovial cyst. Patient recovery was excellent, and he resumed his usual training routine five months later.

  10. Avaliação laríngea em pacientes reumatológicos Laryngeal assessment in reumatic disease patients

    Directory of Open Access Journals (Sweden)

    Hugo Valter Lisboa Ramos

    2005-08-01

    Full Text Available As doenças reumáticas produzem alterações sistêmicas e podem, por isso, comprometer os vasos sangüíneos, as serosas e as mucosas de todo o trato aerodigestivo. Casos esporádicos de acometimento laríngeo por doenças reumáticas têm sido descritos. Esse estudo tem por objetivo avaliar e descrever as alterações laríngeas encontradas em pacientes reumatológicos. FORMA DE ESTUDO: coorte transversal. MATERIAL E MÉTODO: Estudo transversal com pacientes portadores de lúpus eritematoso sistêmico, esclerodermia e doença mista do tecido conjuntivo. Os pacientes submeteram-se a exame clínico otorrinolaringológico e à videolaringoestroboscopia. RESULTADOS: Foram incluídos no estudo 27 pacientes sendo que 26 conseguiram realizar a videolaringoestroboscopia. Alterações laríngeas foram observadas em 11 dos 12 pacientes portadores de lúpus, nos 11 pacientes portadores de esclerodermia e nos 3 pacientes portadores de doença mista do tecido conjuntivo. Lesões sugestivas de nódulo em bambu foram identificados em 5 pacientes e 92,3% dos pacientes apresentaram sinais laríngeos de síndrome faringolaríngea do refluxo. CONCLUSÃO: Neste estudo identificamos 5 lesões sugestivas de nódulos em bambu e sinais laríngeos de refluxo em quase todos os pacientes.Rheumatic diseases usually promote several systemic disorders, which can affect blood vessels, mucosa and serosa of the aerodigestive tract. Scarce laryngeal involvement has been described in these patients and this study aims at investigating laryngeal alterations found in patients with rheumatic diseases. STUDY DESIGN: transversal cohort. MATERIAL AND METHOD: A transversal study was developed with systemic lupus erythematous, systemic sclerosis and mixed connective tissue disease's patients. They were evaluated by means of clinical examinations and videolaryngoestroboscopy. RESULTS: Twenty-seven patients were included in the study, 26 succeeded in completing the

  11. [Double Endobutto reconstituting coracoclavicular ligament combined with repairing acromioclavicular ligament at stage I for the treatment of acromioclavicular dislocation with Rockwood type III - V].

    Science.gov (United States)

    Hu, Wen-yue; Yu, Chong; Huang, Zhong-ming; Han, Lei

    2015-06-01

    To explore clinical efficacy of double Endobutto reconstituting coracoclavicular ligament combined with repairing acromioclavicular ligament in stage I in treating acromioclavicular dislocation with Rockwood type III - V . From January 2010 to September 2013, 56 patients with Rockwood type III - V acromioclavicular dislocation were treated by operation, including 20 males and 36 femlaes, aged from 32 to 52 years old with an average of 38.5 years old. Twenty-five patients were on the left side and 31 cases on the right side. The time from injury to operation was from 3 to 14 days, averaged 7 days. All patients were diagnosed as acromioclavicular dislocation with Rockwood type III - V, and double Endobutto were used to reconstituting coracoclavicular ligament, line metal anchors were applied for repairing acromioclavicular ligament. Postoperative complications were observed, Karlsson and Constant-Murley evaluation standard were used to evaluate clinical effects. All patients were followed up from 8 to 24 months with average of 11 months. According to Karlsson evaluation standard at 6 months after operation,42 cases were grade A, 13 were grade B and 1 was grade C. Constant-Murley score were improved from (42.80±5.43) before operation to (91.75±4.27) at 6 months after operation. All items at 6 months after operation were better than that of preoperative items. Forty-eight patients got excellent results, 7 were moderate and only 1 with bad result. No shoulder joint adhesion, screw loosening or breakage were occurred during following up. Double Endobutto reconstituting coracoclavicular ligament combined with repairing acromioclavicular ligament in stage I for the treatment of acromioclavicular dislocation with Rockwood type III - V could obtain early staisfied clinical effects, and benefit for early recovery of shoulder joint function.

  12. Lumbosacral interspinous ligament rupture associated with acute intrinsic spinal muscle degeneration

    International Nuclear Information System (INIS)

    Jinkins, Randy J.

    2002-01-01

    The objective of this study was to demonstrate lumbosacral interspinous ligament rupture, with or without related acute intrinsic spinal muscle degeneration. This study consisted of a prospective imaging analysis of consecutive 100 MRI studies in adult patients (mean age 56 years) presenting with low back pain. Alterations from the normal in the inter- and perispinal structures of the spine and perispinal soft tissues (e.g., spinal ligaments, perispinal muscles) were sought based upon studies on young volunteers without low back pain (n=10; mean age 23 years). Compared with the group without low back pain, many index cases (n=71, 71%) demonstrated hyperintensity (i.e., sprain or frank ligamentous rupture) of the interspinous ligament(s) on T2-weighted, fat-suppressed MRI studies at one (20 of 71, 28%) or multiple (51 of 71, 72%) levels. Associated intrinsic spinal muscle (e.g., interspinalis, multifidus muscles) degeneration was observed in a minority of cases overall (n=7, 7%), but was only seen in association with cases also demonstrating interspinous ligament degeneration/rupture (7 of 71, 10%). Lumbosacral interspinous ligament sprain or frank rupture, as well as related acute-subacute autotraumatic intrinsic spinal muscle rupture/degeneration, may be overlooked by many observers if fat-suppressed, T2-weighted MRI is not acquired. These musculoligamentous alterations are on occasion the only abnormalities recognized on MRI of the lumbosacral spine and may theoretically be sources of low back morbidity that potentially may respond to specific therapy. Because this study was an observational one, based solely upon medical imaging, future research must focus upon the correlation of the relevance of these findings with an age-matched asymptomatic control group and longitudinal clinicoradiologic therapeutic trials. (orig.)

  13. Preventive lateral ligament tester (PLLT): a novel method to evaluate mechanical properties of lateral ankle joint ligaments in the intact ankle.

    Science.gov (United States)

    Best, Raymond; Böhle, Caroline; Mauch, Frieder; Brüggemann, Peter G

    2016-04-01

    To construct and evaluate an ankle arthrometer that registers inversion joint deflection at standardized inversion loads and that, moreover, allows conclusions about the mechanical strain of intact ankle joint ligaments at these loads. Twelve healthy ankles and 12 lower limb cadaver specimens were tested in a self-developed measuring device monitoring passive ankle inversion movement (Inv-ROM) at standardized application of inversion loads of 5, 10 and 15 N. To adjust in vivo and in vitro conditions, the muscular inactivity of the evertor muscles was assured by EMG in vivo. Preliminary, test-retest and trial-to-trial reliabilities were tested in vivo. To detect lateral ligament strain, the cadaveric calcaneofibular ligament was instrumented with a buckle transducer. After post-test harvesting of the ligament with its bony attachments, previously obtained resistance strain gauge results were then transferred to tensile loads, mounting the specimens with their buckle transducers into a hydraulic material testing machine. ICC reliability considering the Inv-ROM and torsional stiffness varied between 0.80 and 0.90. Inv-ROM ranged from 15.3° (±7.3°) at 5 N to 28.3° (±7.6) at 15 N. The different tests revealed a CFL tensile load of 31.9 (±14.0) N at 5 N, 51.0 (±15.8) at 10 N and 75.4 (±21.3) N at 15 N inversion load. A highly reliable arthrometer was constructed allowing not only the accurate detection of passive joint deflections at standardized inversion loads but also reveals some objective conclusions of the intact CFL properties in correlation with the individual inversion deflections. The detection of individual joint deflections at predefined loads in correlation with the knowledge of tensile ligament loads in the future could enable more individual preventive measures, e.g., in high-level athletes.

  14. Does evaluation of the ligamentous compartment enhance diagnostic utility of sacroiliac joint MRI in axial spondyloarthritis?

    DEFF Research Database (Denmark)

    Weber, Ulrich; Maksymowych, Walter P; Chan, Stanley M

    2015-01-01

    in the ligamentous compartment and their potential diagnostic utility in axial SpA. We therefore aimed to evaluate the ligamentous compartment on sacroiliac joint MRI for lesion distribution and potential incremental value towards diagnosis of SpA over and above the traditional assessment of the cartilaginous...... and ligamentous compartment. The incremental value of evaluating the ligamentous additionally to the cartilaginous compartment alone for diagnosis of SpA was graded qualitatively. We determined the lesion distribution between the two compartments, and the impact of the ligamentous compartment evaluation...... on diagnostic utility. RESULTS: MRI bone marrow lesions solely in the ligamentous compartment in the absence of lesions in the cartilaginous compartment were reported in just 0-2.0/0-4.0 % (BME/fat metaplasia) of all subjects. Additional assessment of the ligamentous compartment was regarded as essential...

  15. Trochleoplasty and medial patellofemoral ligament reconstruction for recurrent patellar dislocation

    Directory of Open Access Journals (Sweden)

    K Raghuveer Reddy

    2012-01-01

    Full Text Available We report a case of recurrent patellar dislocation with high-grade trochlear dysplasia which persisted despite two previous operations. We did a Dejour′s sulcus deepening trochleoplasty, medial patellofemoral ligament reconstruction, and lateral retinacular release. Trochleoplasty and medial patellofemoral ligament reconstruction is required in patients with high grade trochlear dysplasia.

  16. Lise Öğrencilerinin Mobil Öğrenme Araçlarını Kullanma Öz-Yeterlik Düzeylerinin İncelenmesi

    OpenAIRE

    Karaoğlan Yılmaz, Fatma Gizem; Dilen, Anıl; Yılmaz, Hatice

    2018-01-01

    Bu araştırmanın amacı, lise öğrencilerinin mobil öğrenme araçlarını kullanma öz-yeterlik düzeylerini; sınıf düzeyine, cinsiyete, internette geçirilen zamana ve düzenli internet bağlantısına sahip olup olmama durumuna göre incelemektir. Araştırma kapsamında, lise öğrencilerinin mobil öğrenme araçlarını kullanma öz-yeterlik düzeylerini inceleyebilmek için tarama modeli kullanılmıştır. Araştırmanın katılımcıları; 2016-2017 öğretim yılı güz döneminde bir lisede öğrenim görmekte olan ve mobil öğre...

  17. Kullanıcıların Facebook Reklamlarına Tepkilerini Belirleyen Reklam Özellikleri

    OpenAIRE

    Çakır, Vesile; Tam, Mehmet Sinan

    2014-01-01

    Facebook halihazırda en popüler sosyal medyadır ve bu özelliği ile cazip bir reklam medyasıdır. Bu araştırma facebook reklamlarının beğenilmesi, tıklanması ve paylaşılmasında yordayıcı olan reklam özelliklerini araştırmaktadır. Facebook kullanıcıları üzerinde gerçekleştirilen bir saha araştırmasından elde edilen veriler, kullanıcıların ilgilendikleri bir ürün kategorisine ait, tıklanma oranının yüksek, bilim kurgu tarzı, değişik renk ve yazılı bağlantılara sahip ödemeli reklamlara daha çok tı...

  18. Soft error rate estimations of the Kintex-7 FPGA within the ATLAS Liquid Argon (LAr) Calorimeter

    International Nuclear Information System (INIS)

    Wirthlin, M J; Harding, A; Takai, H

    2014-01-01

    This paper summarizes the radiation testing performed on the Xilinx Kintex-7 FPGA in an effort to determine if the Kintex-7 can be used within the ATLAS Liquid Argon (LAr) Calorimeter. The Kintex-7 device was tested with wide-spectrum neutrons, protons, heavy-ions, and mixed high-energy hadron environments. The results of these tests were used to estimate the configuration ram and block ram upset rate within the ATLAS LAr. These estimations suggest that the configuration memory will upset at a rate of 1.1 × 10 −10 upsets/bit/s and the bram memory will upset at a rate of 9.06 × 10 −11 upsets/bit/s. For the Kintex 7K325 device, this translates to 6.85 × 10 −3 upsets/device/s for configuration memory and 1.49 × 10 −3 for block memory

  19. The iliolumbar ligament : its influence on stability of the sacroiliac joint

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; Mulder, P; Spoor, C.W.; Snijders, C.; Stoeckart, R.

    2003-01-01

    STUDY DESIGN: In human specimens the influence of the iliolumbar ligament on sacroiliac joint stability was tested during incremental moments applied to the sacroiliac joints. OBJECTIVES: To assess whether the iliolumbar ligament is able to restrict sacroiliac joint mobility in embalmed cadavers.

  20. Clinical diagnosis of an anterior cruciate ligament rupture : A meta-analysis

    NARCIS (Netherlands)

    Benjammse, A; Gokeler, A; van der Schans, CP

    Study Design: Meta-analysis. Objectives: To define the accuracy of clinical tests for assessing anterior cruciate ligament (ACL) ruptures. Background: The cruciate ligaments, and especially the ACL, are among the most commonly injured structures of the knee. Given the increasing injury prevalence,

  1. Distribution of lymphatic tissues and autonomic nerves in supporting ligaments around the cervix uteri.

    Science.gov (United States)

    Zhang, Jianping; Feng, Lanlan; Lu, Yi; Guo, Dongxia; Xi, Tengteng; Wang, Xiaochun

    2013-05-01

    To investigate the distribution of lymphatic tissues and nerves in the supporting ligaments around the cervix uteri for their tomographical relationship, 9 adult female cadavers were used in this study. Following the incision of all supporting ligaments around the cervix, hematoxylin and esosin (H&E) and immunohistochemical staining of various sections of these ligaments was performed to enable the distribution of lymph tissues and autonomic nerves to be observed. Four lymph nodes were identified in three cadaver specimens. Three lymph nodes were present at a distance of 2.0 cm from the cervix in the cranial side of the cardinal ligaments (CLs), and one lymph node was located at a distance of 4.0 cm from the cervix in the cranial side of the uterosacral ligament (USL). The lymphatic vessels were dispersed in the CLs, scattered in the cervical side of the USLs, and occasionally distributed in the vesicouterine ligaments (VULs). In the CLs, parasympathetic nerves were located at the pelvic lateral wall and went downwards and medially into the cervix, while sympathetic fibers were located in the middle and lower parts of the ligaments. In the USLs, the autonomic nerves, which consisted primarily of sympathetic fibers, went downwards and laterally from the pelvic wall to the cervix. In the VULs, parasympathetic and sympathetic nerves were located in the inner sides of the vesical veins in the deep layers of the ligaments. It is concluded that there are few lymphatic tissues in the supporting ligaments around the cervix uteri, and that nerve‑sparing radical hysterectomy (NSRH) may be a safe method for the treatment of early‑stage cervical cancer.

  2. A Nano-indentation Identification Technique for Viscoelastic Constitutive Characteristics of Periodontal Ligaments.

    Science.gov (United States)

    Ashrafi, H; Shariyat, M

    2016-06-01

    Nano-indentation has recently been employed as a powerful tool for determining the mechanical properties of biological tissues on nano and micro scales. A majority of soft biological tissues such as ligaments and tendons exhibit viscoelastic or time-dependent behaviors. The constitutive characterization of soft tissues is among very important subjects in clinical medicine and especially, biomechanics fields. Periodontal ligament plays an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. It is also the most accessible ligament in human body as it can be directly manipulated without any surgical intervention. From a mechanical point of view, this ligament can be considered as a thin interface made by a solid phase, consisting mainly of collagen fibers, which is immersed into a so-called ground substance. However, the viscoelastic constitutive effects of biological tissues are seldom considered rigorous during Nano-indentation tests. In the present paper, a mathematical contact approach is developed to enable determining creep compliance and relaxation modulus of distinct periodontal ligaments, using constant-rate indentation and loading time histories, respectively. An adequate curve-fitting method is presented to determine these characteristics based on the Nano-indentation of rigid Berkovich tips. Generalized Voigt-Kelvin and Wiechert models are used to model constitutive equations of periodontal ligaments, in which the relaxation and creep functions are represented by series of decaying exponential functions of time. Time-dependent creep compliance and relaxation function have been obtained for tissue specimens of periodontal ligaments. To improve accuracy, relaxation and creep moduli are measured from two tests separately. Stress relaxation effects appear more rapidly than creep in the periodontal ligaments.

  3. A Nano-indentation Identification Technique for Viscoelastic Constitutive Characteristics of Periodontal Ligaments

    Science.gov (United States)

    Ashrafi, H.; Shariyat, M.

    2016-01-01

    Introduction Nano-indentation has recently been employed as a powerful tool for determining the mechanical properties of biological tissues on nano and micro scales. A majority of soft biological tissues such as ligaments and tendons exhibit viscoelastic or time-dependent behaviors. The constitutive characterization of soft tissues is among very important subjects in clinical medicine and especially, biomechanics fields. Periodontal ligament plays an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. It is also the most accessible ligament in human body as it can be directly manipulated without any surgical intervention. From a mechanical point of view, this ligament can be considered as a thin interface made by a solid phase, consisting mainly of collagen fibers, which is immersed into a so-called ground substance. However, the viscoelastic constitutive effects of biological tissues are seldom considered rigorous during Nano-indentation tests. Methods In the present paper, a mathematical contact approach is developed to enable determining creep compliance and relaxation modulus of distinct periodontal ligaments, using constant–rate indentation and loading time histories, respectively. An adequate curve-fitting method is presented to determine these characteristics based on the Nano-indentation of rigid Berkovich tips. Generalized Voigt-Kelvin and Wiechert models are used to model constitutive equations of periodontal ligaments, in which the relaxation and creep functions are represented by series of decaying exponential functions of time. Results Time-dependent creep compliance and relaxation function have been obtained for tissue specimens of periodontal ligaments. Conclusion To improve accuracy, relaxation and creep moduli are measured from two tests separately. Stress relaxation effects appear more rapidly than creep in the periodontal ligaments. PMID:27672630

  4. In vivo metacarpophalanageal joint collateral ligament length changes during flexion.

    Science.gov (United States)

    Sun, Y C; Sheng, X M; Chen, J; Qian, Z W

    2017-07-01

    We investigated the in vivo length changes of the collateral ligaments of metacarpophalangeal joint during flexion. We obtained computed tomography scans of index, middle, ring and little fingers at 0°, 30°, 60° and 90° of joint flexion from six hands of six healthy adult volunteers. Three of them had their dominant right hand studied, and the other three had their non-dominant left hand studied. We measured and analysed the radial and ulnar collateral ligaments of each metacarpophalangeal joint from the reconstructed images. We found that the dorsal and middle portions of the both radial and ulnar collateral ligament lengthened progressively during digital flexion and reached the maximum at 90° flexion. The length of the volar portion increased from 0° to 30° flexion and then decreased from 30° to 60° flexion, reaching the minimum at 90°. In conclusion, three portions of collateral ligaments on both sides of the metacarpophalangeal joint have variable length changes during flexion, which act to stabilize the joint through its flexion arc.

  5. A Soft Gripper with Rigidity Tunable Elastomer Strips as Ligaments.

    Science.gov (United States)

    Nasab, Amir Mohammadi; Sabzehzar, Amin; Tatari, Milad; Majidi, Carmel; Shan, Wanliang

    2017-12-01

    Like their natural counterparts, soft bioinspired robots capable of actively tuning their mechanical rigidity can rapidly transition between a broad range of motor tasks-from lifting heavy loads to dexterous manipulation of delicate objects. Reversible rigidity tuning also enables soft robot actuators to reroute their internal loading and alter their mode of deformation in response to intrinsic activation. In this study, we demonstrate this principle with a three-fingered pneumatic gripper that contains "programmable" ligaments that change stiffness when activated with electrical current. The ligaments are composed of a conductive, thermoplastic elastomer composite that reversibly softens under resistive heating. Depending on which ligaments are activated, the gripper will bend inward to pick up an object, bend laterally to twist it, and bend outward to release it. All of the gripper motions are generated with a single pneumatic source of pressure. An activation-deactivation cycle can be completed within 15 s. The ability to incorporate electrically programmable ligaments in a pneumatic or hydraulic actuator has the potential to enhance versatility and reduce dependency on tubing and valves.

  6. The structure of the coracoacromial ligament: fibrocartilage differentiation does not necessarily mean pathology.

    Science.gov (United States)

    Milz, S; Jakob, J; Büttner, A; Tischer, T; Putz, R; Benjamin, M

    2008-02-01

    The coracoacromial ligament forms part of the coracoacromial arch and is implicated in impingement syndrome and acromial spur formation. Here, we describe its structure and the composition of its extracellular matrix. Ligaments were obtained from 15 cadavers, nine from older people (average age 74.7 years) and six from younger individuals (average age 24.2 years). Cryosections of methanol-fixed tissue were cut and sections were immunolabelled with monoclonal antibodies against collagens, glycosaminoglycans, proteoglycans, matrix proteins and neurofilament proteins. Both ligament entheses were highly fibrocartilaginous and immunolabelled strongly for type II collagen, aggrecan and link protein. The area of labelling was more extensive in older people. However, fibrocartilage also characterized the ligament midsubstance, particularly with increased age. Signs of fibrocartilage degeneration were more common in older people. Ligament fat (containing blood vessels and nerve fibers) was conspicuous in both age groups, especially between fiber bundles at the entheses. We conclude that fibrocartilage is a normal feature but becomes more pronounced with age. It is not necessarily pathological, for it simply indicates that the ligament is subject to compression and/or shear. Nevertheless, the prominence of fibrocartilage at the acromial enthesis may relate to the frequency with which enthesophytes develop.

  7. Role of integrins in the periodontal ligament: organizers and facilitators.

    Science.gov (United States)

    Barczyk, Malgorzata; Bolstad, Anne Isine; Gullberg, Donald

    2013-10-01

    The periodontal ligament is the tissue that connects teeth to bone. The periodontal ligament is a fascinating tissue from a cell biologist's point of view, and because of its special properties and stem-cell content it has also come into the limelight in emerging fields of regenerative medicine. An increased range of genetically modified mouse models offer new tools for studying molecular mechanisms of tooth development. However, owing to species-specific organization of the tooth apparatus, the use of genetic animal models to study the role of the periodontal ligament in normal human tooth physiology and tooth pathology is challenging. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Jee, Won Hee; Im, Soo A; Chun, Ho Jong; Jung, Hyun Seouk; Kim, Soo Young; Kwon, Tae An; Song, Sun Wha; Choi, Kyu Ho

    1998-01-01

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema

  9. Tendon and ligament as novel cell sources for engineering the knee meniscus.

    Science.gov (United States)

    Hadidi, P; Paschos, N K; Huang, B J; Aryaei, A; Hu, J C; Athanasiou, K A

    2016-12-01

    The application of cell-based therapies in regenerative medicine is hindered by the difficulty of acquiring adequate numbers of competent cells. For the knee meniscus in particular, this may be solved by harvesting tissue from neighboring tendons and ligaments. In this study, we have investigated the potential of cells from tendon and ligament, as compared to meniscus cells, to engineer scaffold-free self-assembling fibrocartilage. Self-assembling meniscus-shaped constructs engineered from a co-culture of articular chondrocytes and either meniscus, tendon, or ligament cells were cultured for 4 weeks with TGF-β1 in serum-free media. After culture, constructs were assessed for their mechanical properties, histological staining, gross appearance, and biochemical composition including cross-link content. Correlations were performed to evaluate relationships between biochemical content and mechanical properties. In terms of mechanical properties as well as biochemical content, constructs engineered using tenocytes and ligament fibrocytes were found to be equivalent or superior to constructs engineered using meniscus cells. Furthermore, cross-link content was found to be correlated with engineered tissue tensile properties. Tenocytes and ligament fibrocytes represent viable cell sources for engineering meniscus fibrocartilage using the self-assembling process. Due to greater cross-link content, fibrocartilage engineered with tenocytes and ligament fibrocytes may maintain greater tensile properties than fibrocartilage engineered with meniscus cells. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Effect of the Periodontal Ligament of the Bilateral Support Teeth on the Stress Analysis of Dental Implant

    Directory of Open Access Journals (Sweden)

    Xie Yanhua

    2017-01-01

    Full Text Available The aim of this work is to analyze the function of natural teeth’s periodontal ligament and the effects of periodontal ligament on implants by the finite element method (FEM, when static functional loads occur. The finite element analysis models are established, which consist of fragment of mandible, natural teeth, periodontal ligament, and implant. Finite element software Abaqus is used to analyze the stress transfer in models with or without periodontal ligament, and mandibular first molar is implant. The implant obtained the maximum stress value of 87.71MPa when periodontal ligament of natural tooth is absent, but the maximum value reduces to 38.43 MPa with the action of periodontal ligament. It illustrates that periodontal ligament has significant effects on stress transfer. When the finite element model of single natural tooth or dentition with implant is generated, periodontal ligament should be taken into account.

  11. Novel strategies in tendon and ligament tissue engineering: Advanced biomaterials and regeneration motifs

    OpenAIRE

    Kuo Catherine K; Marturano Joseph E; Tuan Rocky S

    2010-01-01

    Abstract Tendon and ligaments have poor healing capacity and when injured often require surgical intervention. Tissue replacement via autografts and allografts are non-ideal strategies that can lead to future problems. As an alternative, scaffold-based tissue engineering strategies are being pursued. In this review, we describe design considerations and major recent advancements of scaffolds for tendon/ligament engineering. Specifically, we outline native tendon/ligament characteristics criti...

  12. Review of Politics as Form in Lars von Trier: A Post-Brechtian Reading

    Directory of Open Access Journals (Sweden)

    Sara Marino

    2014-10-01

    Full Text Available Controversial and unconventional designer of formal experimentations, simultaneously celebrated and despised around the world, performative to a point that realism is achieved through the manipulation of realistic conventions hidden in everyday forms of human interactions, von Trier is indeed one of the most important contemporary filmmakers within European cinema, as well as the protagonist of Koutsourakis’s Politics as Form in Lars von Trier: A Post-Brechtian Reading.

  13. Background suppression in Gerda Phase II and its study in the LArGe low background set-up

    Energy Technology Data Exchange (ETDEWEB)

    Budjas, Dusan [Physik-Department E15, Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    In Phase II of the Gerda experiment additional ∝20 kg of BEGe-type germanium detectors, enriched in {sup 76}Ge, will be deployed in liquid argon (LAr) to further increase the sensitivity for the half-life of neutrinoless double beta (0νββ) decay of {sup 76}Ge to > 2 . 10{sup 26} yr. To reduce background by a factor of 10 to the required level of < 10{sup -3} cts/(keV.kg.yr), it is necessary to employ active background-suppression techniques, including anti-Compton veto using scintillation light detection from LAr and pulse shape discrimination exploiting the characteristic electrical field distribution inside BEGe detectors. The latter technique can identify single-site events (typical for 0νββ) and efficiently reject multi-site events (mainly from γ-rays), as well as different types of background events from detector surfaces. The combined power of these techniques was studied for {sup 42}K and other background sources at the low background facility LArGe. Together with extensive simulations, the information from tracking of the Phase II detector material exposure to cosmic rays and based on the background contributions observed in Phase I, the expected background level in Phase II in the region of interest at 2039 keV, the Q{sub ββ} energy of {sup 76}Ge, is estimated. The preliminary analysis shows that contributions from all expected background components after all cuts are in line with the goal of Gerda Phase II.

  14. The effect of constitutive representations and structural constituents of ligaments on knee joint mechanics.

    Science.gov (United States)

    Orozco, Gustavo A; Tanska, Petri; Mononen, Mika E; Halonen, Kimmo S; Korhonen, Rami K

    2018-02-02

    Ligaments provide stability to the human knee joint and play an essential role in restraining motion during daily activities. Compression-tension nonlinearity is a well-known characteristic of ligaments. Moreover, simpler material representations without this feature might give reasonable results because ligaments are primarily in tension during loading. However, the biomechanical role of different constitutive representations and their fibril-reinforced poroelastic properties is unknown. A numerical knee model which considers geometric and material nonlinearities of meniscus and cartilages was applied. Five different constitutive models for the ligaments (spring, elastic, hyperelastic, porohyperelastic, and fibril-reinforced porohyperelastic (FRPHE)) were implemented. Knee joint forces for the models with elastic, hyperelastic and porohyperelastic properties showed similar behavior throughout the stance, while the model with FRPHE properties exhibited lower joint forces during the last 50% of the stance phase. The model with ligaments as springs produced the lowest joint forces at this same stance phase. The results also showed that the fibril network contributed substantially to the knee joint forces, while the nonfibrillar matrix and fluid had small effects. Our results indicate that simpler material models of ligaments with similar properties in compression and tension can be used when the loading is directed primarily along the ligament axis in tension.

  15. Injured lateral ankle ligaments: technique and assessment of MRI

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Trattnig, S.; Kukla, C.; Gaebler, C.; Kaider, A.; Haller, J.; Heinz-Peer, G.; Imhof, H.

    1996-01-01

    56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T 1 w-SE and T 2 w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [de

  16. Functional anatomy of the lateral collateral ligament of the elbow.

    Science.gov (United States)

    Hackl, M; Bercher, M; Wegmann, K; Müller, L P; Dargel, J

    2016-07-01

    The aim of this study was to analyze the functional anatomy of the lateral collateral ligament complex (LCLC) and the surrounding forearm extensors. Using 81 human cadaveric upper extremities, the anatomy of the forearm extensors-especially the anconeus, supinator and extensor carpi ulnaris (ECU)-was analyzed. After removal of aforementioned extensors the functional anatomy of the LCLC was analyzed. The origin of the LCLC was evaluated for isometry. The insertion types of the lateral ulnar collateral ligament (LUCL) were analyzed and classified. The ECU runs parallel to the RCL to dynamically preserve varus stability. The supinator and anconeus muscle fibers coalesce with the LCLC and lengthen during pronation. The anconeus fibers run parallel to the LUCL in full flexion. The LCLC consists of the annular ligament (AL) and the isometric radial collateral ligament (RCL). During elbow flexion, its posterior branches (LUCL) tighten while the anterior branches loosen. When performing a pivot shift test, the loosened LUCL fibers do not fully tighten in full extension. The LUCL inserts along with the AL at the supinator crest. Three different insertion types could be observed. The LUCL represents the posterior branch of the RCL rather than a distinct ligament. It is non-isometric and lengthens during elbow flexion. The RCL was found to be of vital importance for neutralization of posterolateral rotatory forces. Pronation of the forearm actively stabilizes the elbow joint as the supinator, anconeus and biceps muscle work in unison to increase posterolateral rotatory stability.

  17. Comparison of potentials between stem cells isolated from human anterior cruciate ligament and bone marrow for ligament tissue engineering.

    Science.gov (United States)

    Cheng, Ming-Te; Liu, Chien-Lin; Chen, Tain-Hsiung; Lee, Oscar K

    2010-07-01

    We have previously isolated and identified stem cells from human anterior cruciate ligament (ACL). The purpose of this study was to evaluate the differences in proliferation, differentiation, and extracellular matrix (ECM) formation abilities between bone marrow stem cells (BMSCs) and ACL-derived stem cells (LSCs) from the same donors when cultured with different growth factors, including basic fibroblast growth factor (bFGF), epidermal growth factor, and transforming growth factor-beta 1 (TGF-beta1). Ligament tissues and bone marrow aspirate were obtained from patients undergoing total knee arthroplasty and ACL reconstruction surgeries. Proliferation, colony formation, and population doubling capacity as well as multilineage differentiation potentials of LSCs and BMSCs were compared. Gene expression and ECM production for ligament engineering were also evaluated. It was found that BMSCs possessed better osteogenic differentiation potential than LSCs, while similar adipogenic and chondrogenic differentiation abilities were observed. Proliferation rates of both LSCs and BMSCs were enhanced by bFGF and TGF-beta1. TGF-beta1 treatment significantly increased the expression of type I collagen, type III collagen, fibronectin, and alpha-smooth muscle actin in LSCs, but TGF-beta1 only upregulated type I collagen and tenascin-c in BMSCs. Protein quantification further confirmed the results of differential gene expression and suggested that LSCs and BMSCs increase ECM production upon TGF-beta1 treatment. In summary, in comparison with BMSCs, LSCs proliferate faster and maintain an undifferentiated state with bFGF treatment, whereas under TGF-beta1 treatment, LSCs upregulate major tendinous gene expression and produce a robust amount of ligament ECM protein, making LSCs a potential cell source in future applications of ACL tissue engineering.

  18. Elamu Silgu tänaval Tallinnas = Dwelling on Silgu Street in Tallinn / Ülar Mark, Indrek Tiigi

    Index Scriptorium Estoniae

    Mark, Ülar

    2003-01-01

    Klaasmaja projekteerija: Arhitektuuribüroo Urban Mark. Arhitektid Ülar Mark ja Indrek Tiigi. Konstruktor: Inseneribüroo Peipman OÜ. Sisekujundaja Raina Lillepõld (OÜ Boxes). Projekt 2002, valmis 2004. 4 välis- ja 3 sisevaadet, põhiplaan

  19. Effects of glucosamine on proteoglycan loss by tendon, ligament and joint capsule explant cultures.

    Science.gov (United States)

    Ilic, M Z; Martinac, B; Samiric, T; Handley, C J

    2008-12-01

    To investigate the effect of glucosamine on the loss of newly synthesized radiolabeled large and small proteoglycans by bovine tendon, ligament and joint capsule. The kinetics of loss of (35)S-labeled large and small proteoglycans from explant cultures of tendon, ligament and joint capsule treated with 10mM glucosamine was investigated over a 10-day culture period. The kinetics of loss of (35)S-labeled small proteoglycans and the formation of free [(35)S]sulfate were determined for the last 10 days of a 15-day culture period. The proteoglycan core proteins were analyzed by gel electrophoresis followed by fluorography. The metabolism of tendon, ligament and joint capsule explants exposed to 10mM glucosamine was evaluated by incorporation of [(3)H]serine and [(35)S]sulfate into protein and glycosaminoglycans, respectively. Glucosamine at 10mM stimulated the loss of small proteoglycans from ligament explant cultures. This was due to the increased loss of both macromolecular and free [(35)S]sulfate to the medium indicating that glucosamine affected the release of small proteoglycans as well as their intracellular degradation. The degradation pattern of small proteoglycans in ligament was not affected by glucosamine. In contrast, glucosamine did not have an effect on the loss of large or small proteoglycans from tendon and joint capsule or large proteoglycans from ligament explant cultures. The metabolism of cells in tendon, ligament and joint capsule was not impaired by the presence of 10mM glucosamine. Glucosamine stimulated the loss of small proteoglycans from ligament but did not have an effect on small proteoglycan catabolism in joint capsule and tendon or large proteoglycan catabolism in ligament, tendon or synovial capsule. The consequences of glucosamine therapy at clinically relevant concentrations on proteoglycan catabolism in joint fibrous connective tissues need to be further assessed in an animal model.

  20. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  1. MRI appearance of the distal insertion of the anterior cruciate ligament of the knee: an additional criterion for ligament ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Oldrini, G.; Teixeira, P.G.; Chanson, A.; Osemont, B.; Louis, M.; Blum, A. [CHU Nancy, Service d' imagerie Guilloz, Nancy (France); Erpelding, M.L. [CHU Nancy, Hopitaux de Brabois Allee du Morvan, Service Epidemiologie et Evaluation Cliniques, Vandoeuvre-les-Nancy (France)

    2012-09-15

    Anterior cruciate ligament tears are frequent and if not diagnosed may lead to relevant patient disability. Magnetic resonance imaging is the method of choice for the non-invasive diagnosis of these tears. Despite the high performance of this method some cases are challenging and the criteria described in the literature are not sufficient to reach a diagnosis. We propose a systematic method for the evaluation of anterior cruciate ligament tears based on the aspect of its distal portion. Magnetic resonance studies of 132 knees were evaluated in correlation with arthroscopy. The performance of the proposed method was compared with that of classic imaging signs of anterior cruciate ligament tear. The impact of image quality and reader expertise on the proposed method and the classic signs of tear were taken into account. This method had a sensitivity and specificity of 91.1% and 82.9% for the detection of abnormal ACLs. The interobserver agreement (kappa) of the proposed method was significantly higher than that of the classic signs at all levels of expertise (0.89 vs 0.76). This method was not influenced by image quality. Distal ACL analysis identified more partial tears and synovialization (granulation scar tissue) than the conventional method (71% vs 58.5% for partial tears and 83.5% vs 58.5% for synovialization). The proposed classification has a high performance and reproducibility for the identification of abnormal anterior cruciate ligament. The results were influenced neither by the level of expertise of the readers nor by the image quality. (orig.)

  2. Case study of a 15-year-old boy with McCune-Albright syndrome combined with pituitary gigantism: effect of octreotide-long acting release (LAR) and cabergoline therapy.

    Science.gov (United States)

    Tajima, Toshihiro; Tsubaki, Junko; Ishizu, Katsura; Jo, Wakako; Ishi, Nobuaki; Fujieda, Kenji

    2008-07-01

    The use of octreotide-LAR and cabergoline therapy has shown great promise in adults with acromegaly; however, the experience in pediatric patients has rarely been reported. We described a clinical course of a 15-year-old boy of McCune-Albright syndrome (MAS) with pituitary gigantism. At the age of 8 years, a growth hormone (GH) and prolactin (PRL) producing pituitary adenoma was diagnosed at our hospital. He also had multiple fibrous dysplasia, so that he was diagnosed as having MAS. The tumor was partially resected, and GNAS1 gene mutation (R201C) was identified in affected tissues. We introduced octreotide to suppress GH secretion (100 mug 2/day s.c). During therapy with octreotide, IGF-1 and GH levels could not be suppressed and the patient frequently complained of nausea from octreotide treatment. Therefore, the therapy was changed to monthly injections of octreotide-LAR at the age of 12.3 years and was partially effective. However, as defect of left visual field worsened due to progressive left optic canal stenosis, he underwent second neurological decompression of the left optic nerve at 13.4 years of age. After surgery, in addition to octreotide-LAR, cabergoline (0.25 mg twice a month) was started. This regimen normalized serum levels of GH and IGF-1; however, he showed impaired glucose tolerance and gallstones at 15.7 years of age. Therefore, the dose of octreotide-LAR was reduced to 10 mg and the dose of cabergoline increased. This case demonstrated the difficulty of treating pituitary gigantism due to MAS. The use of octreotide-LAR and cabergoline should be considered even in pediatric patients; however, adverse events due to octreotide-LAR must be carefully examined.

  3. Acromioclavicular dislocation: postoperative evaluation of the coracoclavicular ligaments using magnetic resonance

    Directory of Open Access Journals (Sweden)

    Rafael Salomon Silva Faria

    2015-04-01

    Full Text Available OBJECTIVE: To radiologically evaluate the healing of the coracoclavicular ligaments after surgical treatment for acromioclavicular dislocation.METHODS: Ten patients who had undergone surgical treatment for acromioclavicular dislocation via a posterosuperior route at least one year earlier were invited to return for radiological assessment using magnetic resonance. This evaluation was done by means of analogy with the scale described in the literature for studying the healing of the anterior cruciate ligament of the knee and for measuring the healed coracoclavicular ligaments.RESULTS: A scar structure of fibrous appearance had formed in 100% of the cases. In 50% of the cases, the images of this structure had a good appearance, while the other 50% were deficient.CONCLUSION: Late postoperative evaluation using magnetic resonance, on patients who had been treated for acute acromioclavicular dislocation using a posterosuperior route in the shoulder, showed that the coracoclavicular ligaments had healed in 100% of the cases, but that this healing was deficient in 50%.

  4. Development of an ADC Radiation Tolerance Characterization System for the Upgrade of the ATLAS LAr Calorimeter

    CERN Document Server

    INSPIRE-00445642; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge

    2016-01-01

    ATLAS LAr calorimeter will perform its Phase-I upgrade during the long shut down (LS2) in 2018, a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multichannel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for LTDB. In order to evaluate the radiation tolerance of these back up commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, which has ADC driver and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as DAQ board. The data from ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed wit...

  5. Lar Betânia: O atendimento à infância abandonada em Maringá – PR

    Directory of Open Access Journals (Sweden)

    Ângela Mara de Barros Lara

    2012-08-01

    Full Text Available O presente artigo discute as políticas públicas de atendimento à criança e ao adolescenteem situação social de risco, na cidade de Maringá-PR, por meio da história do Lar Betânia,um abrigo fundado em 1965, no sistema casa-lar. A instituição que, em muitos períodos desua história chegou a atender, simultaneamente, 100 crianças vive hoje, a possibilidade desucumbir diante da atual filosofia do Estado de priorizar a permanência do menor junto àfamília biológica e, na impossibilidade dessa convivência, encaminhá-lo para acolhimento,junto às famílias cadastradas e preparadas para atuarem como famílias temporárias. Estadiscussão só foi possível a partir do estudo dos pressupostos que evidenciam o papel doEstado e dos direitos sociais na sociedade em que vivemos.

  6. Subject-Specific Carpal Ligament Elongation in Extreme Positions, Grip, and the Dart Thrower's Motion

    Science.gov (United States)

    Rainbow, Michael J.; Kamal, Robin N.; Moore, Douglas C.; Akelman, Edward; Wolfe, Scott W.; Crisco, Joseph J.

    2015-01-01

    This study examined whether the radiocarpal and dorsal capsular ligaments limit end-range wrist motion or remain strained during midrange wrist motion. Fibers of these ligaments were modeled in the wrists of 12 subjects over multiple wrist positions that reflect high demand tasks and the dart thrower's motion. We found that many of the volar and dorsal ligaments were within 5% of their maximum length throughout the range of wrist motion. Our finding of wrist ligament recruitment during midrange and end-range wrist motion helps to explain the complex but remarkably similar intersubject patterns of carpal motion. PMID:26367853

  7. MR imaging diagnosis of posterior cruciate ligament injury: importance of ancillary findings

    International Nuclear Information System (INIS)

    Hwang, Kang Ik; Lee, Jong Hwa; Kim, Young Sun; Lee, Jung Hwoi; Ki, Tae Sung; Park, Jong Oag

    1997-01-01

    To evaluate the importance of two ancillary findings of anterior tibial plateau bruise/fracture and popliteus muscle strain on MR diagnosis of posterior cruicate ligament injury. We retrospectively evaluated 48 patients with confirmed posterior cruciate ligament tear. We studied the incidence of anterior tibial plateau injury and popliteus muscle strain, and the specificity of popliteus muscle strain with or without bony injury. A complete tear of the posterior cruciate ligament was noted in 37 cases, a partial tear in 11. Anterior tibial plateau lesion was found in 21 of 48 cases (44%); This total was made up of 17/37 PCL complete tears (46%) and 4/11 partial tears (36%). The difference in the incidence of complete and partial tears is not statistically significant. Popliteus muscle injury was found in 20 of 48 cases (42%), the total consisted of 19/37 PCL complete tears (51%) and 1/11 partial tears (10%). The incidence of 42% is relatively high, approximating that of bony injury. The difference in the incidence of complete and partial tears is statistically significant (p < 0.006). Specificity for posterior cruciate ligament tear is 69%(20/29), and when concomitant with anterior tibial plateau injury is 94%(16/17). As in the case of anterior cruciate ligament injury, these documented ancillary findings of anterior tibial plateau and popliteus muscle injuries are very helpful when MR diagnosis of posterior cruciate ligament injury itself and differentiation of partial and complete rupture are doubtful

  8. Novel Treatment of a Scapholunate Ligament Injury with Proximal Pole Scaphoid Nonunion

    Science.gov (United States)

    Gaspar, Michael P.; Kane, Patrick M.; Jacoby, Sidney M.; Culp, Randall W.

    2016-01-01

    Background  Nonunion of scaphoid proximal pole fractures presents a challenging management dilemma to hand surgeons. This problem is further complicated in the uncommon concurrence of scapholunate (SL) ligament disruption. Case Description  A 39-year-old male patient presented with new-onset wrist pain following a remote history of a proximal pole scaphoid fracture sustained as a teenager, which was treated nonoperatively. Six months before presentation, the patient sustained a fall while snowboarding. The patient was found to have a chronic nonunion of his scaphoid proximal pole with an associated SL ligament disruption. As the proximal fragment was too small to be amenable to fixation, the patient was treated with an arthroscopic partial scaphoid excision and SL ligament reconstruction using a scapholunateintercarpal screw placed percutaneously. At 26 months, the patient exhibited no pain, near-normal strength, and wrist motion, and expressed a high-level of satisfaction from his surgery. Literature Review  Although cases of SL ligament disruption with concomitant proximal scaphoid fractures have been reported, to our knowledge, this is the first report of SL ligament rupture occurring in the setting of a preexisting proximal pole scaphoid nonunion. Clinical Relevance  We report the use of SL ligament reconstruction augmented with intercarpal screw fixation, and excision of the proximal pole scaphoid nonunion. This minimallyinvasive approach may be a particularly useful option in young, active patients such as our own, where a motion-sacrificing salvage procedure would be less than ideal. PMID:27616829

  9. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    Science.gov (United States)

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  10. Treatment of chronic deltoid ligament injury using suture anchors.

    Science.gov (United States)

    Wang, Xu; Ma, Xin; Zhang, Chao; Wang, Chen; Huang, Jia-zhang

    2014-08-01

    To explore the efficacy of overlapping suture-anchor fixation for treatment of chronic deltoid ligament injury. Seventeen patients (11 men, 6 women of mean age 32.1 years [range, 18-58 years]) who had undergone surgery for chronic deltoid ligament injury from January 2007 to December 2011 were retrospectively analyzed. Preoperatively, they had undergone bilateral weight-bearing posterior-anterior radiographs, (MRI) and ultrasound examinations of the ankle. Ankle arthroscopy was performed to confirm the diagnosis, followed by surgery to clear intra-articular proliferating synovial tissues and remove cartilage debris and scar tissue. The deep layer of the deltoid ligament was sutured onto the tip of the medial malleolus and its superficial layer sutured onto its periosteum and fixed with suture anchors. American Orthopedic Foot and Ankle Society (AOFAS) scoring system for the ankle-hindfoot was used to evaluate the ankles pre- and post-operatively. The 17 patients were followed up for 12-34 months (mean 20.1 months). The angle between the long axes of the talus and first metatarsal and the hindfoot angle measured in a hindfoot alignment view (as described by Saltzman) were reduced from 5.4° ± 1.8° and 8.2° ± 2.6° preoperatively to 4.0° ± 0.9° and 5.3° ± 1.3° postoperatively, respectively. The mean AOFAS ankle-hindfoot score was 76.8 ± 7.0 preoperatively and 94.1 ± 3.3 at the last follow-up visit. Ten patients were scored as excellent, six as good, and one as fair. Pain was relieved in all patients and no patients had recurrent deltoid ligament injury. Using suture anchors to treat chronic deltoid ligament injury has relatively satisfactory outcomes. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  11. Aynı coğrafyada iki savaş: Troia ve Çanakkale savaşlarının karşılaştırılması

    OpenAIRE

    Körpe, Reyhan

    2015-01-01

    Yaklaşık üç bin yıl arayla aynı topraklarda meydana gelen iki savaş, Troia ve Çanakkale Savaşları sadece coğrafi benzerlikleri değil, nedenleri, oluş şekli ve sonuçları ile birbirine benzemektedir. Birinci Dünya savaşının bir parçası olan Çanakkale Savaşı gibi, arkeolojik kaynaklar Homeros’un destanlaştırdığı Troia Savaşı’nın Tunç Çağların sonunda Batı Anadolu’daki çok büyük bir mücadelenin parçası olduğunu ortaya koymuştur. Çanakkale Savaşları sırasında kullanılan yöntemlerin antik çağ savaş...

  12. Ingestão de energia e nutrientes segundo consumo de alimentos fora do lar na Região Nordeste: uma análise do Inquérito Nacional de Alimentação 2008-2009

    Directory of Open Access Journals (Sweden)

    Jessica Brito Cavalcante

    Full Text Available RESUMO: Introdução: O consumo de alimentos fora do lar vem crescendo no Brasil, sendo associado a escolhas alimentares menos nutritivas. Objetivo: Descrever a ingestão de energia e nutrientes específicos entre consumidores e não consumidores de alimentos fora do lar, na Região Nordeste. Métodos: Foram analisados dados do Inquérito Nacional de Alimentação (INA, provenientes da Pesquisa de Orçamentos Familiares (POF 2008-2009, em uma amostra de 11.674 indivíduos residentes na Região Nordeste, que forneceram dois registros alimentares em dias não consecutivos, com informação sobre o local de consumo dos alimentos (dentro ou fora do lar. Alimentação fora do lar foi definida como todo alimento adquirido e consumido fora de casa. Modelos de regressão linear foram desenvolvidos para avaliar a relação entre o consumo alimentar fora do lar em um dos dois dias de registro e a ingestão de energia e nutrientes, ajustados por idade, sexo e renda per capita. Resultados: O consumo de alimentos fora do lar, em pelo menos um dos dois dias de registro alimentar, foi reportado por 42% dos indivíduos. Os indivíduos que consomem alimentos fora do lar apresentaram pior ingestão de nutrientes em comparação com os que não consomem alimentos fora do lar, com maior consumo de energia, açúcar livre, gordura saturada, gordura trans e menor ingestão de proteína, ferro e fibra alimentar, independente da idade, sexo e renda (p < 0,05. Conclusão: A alimentação fora do lar no Nordeste contribuiu para uma maior ingestão de energia e uma pior ingestão de nutrientes. Assim, faz-se necessária a elaboração de políticas públicas e estratégias que favoreçam a escolha de alimentos mais saudáveis quando os indivíduos optam por se alimentar fora do lar.

  13. Ortaöğretim Öğrencilerinin Yazma Eğilimi Algıları

    Directory of Open Access Journals (Sweden)

    Ercan Deniz

    2015-04-01

    Full Text Available Bu araştırmanın amacı, ortaöğretim öğrencilerinin yazma eğilimi algılarının genel düzeyini tespit ederek yazma eğilimi algısını cinsiyet, sınıf düzeyi, öğrenim alanı, anne eğitim durumu, baba eğitim durumu, kitap okuma sıklığı, facebook ve e-mail kullanma durumlarına göre incelemektir. Araştırma 2013-2014 eğitim-öğretim yılında tesadüfi örnekleme yoluyla seçilen resmi bir okuldaki 317 öğrenci üzerinde yürütülmüştür. Elde edilen veriler SPSS 20.0 paket programı kullanılarak analiz edilmiştir. Verilerin analizinde ilişkisiz örneklem t testi, tek yönlü varyans analizi ve pearson momentler çarpımı korelasyonu kullanılmıştır. Araştırmada elde edilen bulgulara göre ortaöğretim öğrencilerinin yazma eğilimi algılarının “orta düzeyde” olduğu sonucuna ulaşılmıştır. Öğrencilerin yazma eğilimi algılarının cinsiyet, sınıf düzeyi, öğrenim alanı ve kitap okuma sıklığı değişkenlerine göre anlamlı bir farlılık gösterdiği tespit edilmiştir. Anne ve baba eğitim durumuyla facebook ve e-mail kullanma değişkenlerinin yazma eğilimi algısıyla istatiksel olarak anlamlı bir ilişkisi bulunmamaktadır.

  14. Snow reliability in ski resorts considering artificial snowmaking

    Science.gov (United States)

    Hofstätter, M.; Formayer, H.; Haas, P.

    2009-04-01

    Snow reliability is the key factor to make skiing on slopes possible and to ensure added value in winter tourism. In this context snow reliability is defined by the duration of a snowpack on the ski runs of at least 50 mm snow water equivalent (SWE), within the main season (Dec-Mar). Furthermore the snowpack should form every winter and be existent early enough in season. In our work we investigate the snow reliability of six Austrian ski resorts. Because nearly all Austrian resorts rely on artificial snowmaking it is of big importance to consider man made snow in the snowpack accumulation and ablation in addition to natural snow. For each study region observed weather data including temperature, precipitation and snow height are used. In addition we differentiate up to three elevations on each site (valley, intermediate, mountain top), being aware of the typical local winter inversion height. Time periods suitable for artificial snow production, for several temperature threshold (-6,-4 or -1 degree Celsius) are calculated on an hourly base. Depending on the actual snowpack height, man made snow can be added in the model with different defined capacities, considering different technologies or the usage of additives. To simulate natural snowpack accumulation and ablation we a simple snow model, based on daily precipitation and temperature. This snow model is optimized at each site separately through certain parameterization factors. Based on the local observations and the monthly climate change signals from the climate model REMO-UBA, we generate long term time series of temperature and precipitation, using the weather generator LARS. Thereby we are not only able to simulate the snow reliability under current, but also under future climate conditions. Our results show significant changes in snow reliability, like an increase of days with insufficient snow heights, especially at mid and low altitudes under natural snow conditions. Artificial snowmaking can partly

  15. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture.

    Science.gov (United States)

    Bai, Rong-Jie; Zhang, Hui-Bo; Zhan, Hui-Li; Qian, Zhan-Hua; Wang, Nai-Li; Liu, Yue; Li, Wen-Ting; Yin, Yu-Ming

    2018-05-05

    Hand injuries are very common in sports, such as skiing and ball sports. One of the major reasons causing hand and finger deformity is due to ligament and tendon injury. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) can demonstrate the complex anatomy of the fingers and thumb, especially the tendons and ligaments, and provide the accurate diagnosis of clinically important fingers and thumbs deformity due to ligamentous and tendinous injuries during sport activities. Sixteen fresh un-embalmed cadaveric hands were harvested from eight cadavers. A total of 20 healthy volunteers' hands and 44 patients with fingers or thumb deformity due to sports-related injuries were included in this study. All subjects had MR examination with T1-weighted images and proton density-weighted imaging with fat suppression (PD FS) in axial, coronal, and sagittal plane, respectively. Subsequently, all 16 cadaveric hands were sliced into 2-mm thick slab with a band saw (six in coronal plane, six in sagittal plane, and four in axial plane). The correlation of anatomic sections and the MRI characteristics of tendons of fingers and the ulnar collateral ligament (UCL) at the metacarpal phalangeal joint (MCPJ) of thumb between 20 healthy volunteers and 44 patients (confirmed by surgery) were analyzed. The normal ligaments and tendons in 16 cadaveric hands and 20 volunteers' hands showed uniform low-signal intensity on all the sequences of the MRI. Among 44 patients with tendinous and ligamentous injuries in the fingers or thumb, 12 cases with UCL injury at MCPJ of the thumb (Stener lesion = 8 and non-Stener lesion = 4), 6 cases with the central slip injury, 12 cases with terminal tendon injury, and 14 cases with flexor digitorum profundus injury. The ligaments and tendons disruption manifested as increased signal intensity and poor definition, discontinuity, and heterogeneous signal intensity of the involved ligaments and tendons. Sports

  16. RESULTS OF DIAGNOSTICAL BLOCK OF LONG DORSAL SACROILIAC LIGAMENT UNDER SONOGRAPHIC CONTROL IN PATIENTS WITH LOW BACK PAIN

    Directory of Open Access Journals (Sweden)

    Yurkovskiy A. M.

    2018-02-01

    Full Text Available Purpose: to improve effectiveness of diagnostic block of long dorsal sacroiliac ligament performed under sonographic control in patients with low back pain caused by pathology of this ligament. Material and methods: the research included 35 patients (average age 46,2±12,5 years with symptoms of low back pain caused by pathology of long dorsal sacroiliac ligament. Diagnostical block of the given ligament was made under ultrasound control. Results: significant pain syndrome reduction was observed in all patients with ligamentopathy of long dorsal sacroiliac ligament. Conclusion: compared to "blind" technique, long dorsal sacroiliac ligament block performed under sonographic control is a more efficient method of verification and treatment for low back pain syndrome in case of long dorsal sacroiliac ligament injury.

  17. Pelvic belt effects on sacroiliac joint ligaments: a computational approach to understand therapeutic effects of pelvic belts.

    Science.gov (United States)

    Sichting, Freddy; Rossol, Jerome; Soisson, Odette; Klima, Stefan; Milani, Thomas; Hammer, Niels

    2014-01-01

    The sacroiliac joint is a widely described source of low back pain. Therapeutic approaches to relieve pain include the application of pelvic belts. However, the effects of pelvic belts on sacroiliac joint ligaments as potential pain generators are mostly unknown. The aim of our study was to analyze the influence of pelvic belts on ligament load by means of a computer model. Experimental computer study using a finite element method. A computer model of the human pelvis was created, comprising bones, ligaments, and cartilage. Detailed geometries, material properties of ligaments, and in-vivo pressure distribution patterns of a pelvic belt were implemented. The effects of pelvic belts on ligament strain were computed in the double-leg stance. Pelvic belts increase sacroiliac joint motion around the sagittal axis but decrease motion around the transverse axis. With pelvic belt application, most of the strained sacroiliac joint ligaments were relieved, especially the sacrospinous, sacrotuberous, and the interosseous sacroiliac ligaments. Sacroiliac joint motion and ligament strains were minute. These results agree with validation data from other studies. Assigning homogenous and linear material properties and excluding muscle forces are clear simplifications of the complex reality. Pelvic belts alter sacroiliac joint motion and provide partial relief of ligament strain that is subjectively marked, although minimal in absolute terms. These findings confirm theories that besides being mechanical stabilizers, the sacroiliac joint ligaments are likely involved in neuromuscular feedback mechanisms. The results from our computer model help with unraveling the therapeutic mechanisms of pelvic belts.

  18. In vitro characterization of self-assembled anterior cruciate ligament cell spheroids for ligament tissue engineering.

    Science.gov (United States)

    Hoyer, M; Meier, C; Breier, A; Hahner, J; Heinrich, G; Drechsel, N; Meyer, M; Rentsch, C; Garbe, L-A; Ertel, W; Lohan, A; Schulze-Tanzil, G

    2015-03-01

    Tissue engineering of an anterior cruciate ligament (ACL) implant with functional enthesis requires site-directed seeding of different cell types on the same scaffold. Therefore, we studied the suitability of self-assembled three-dimensional spheroids generated by lapine ACL ligament fibroblasts for directed scaffold colonization. The spheroids were characterized in vitro during 14 days in static and 7 days in dynamic culture. Size maintenance of self-assembled spheroids, the vitality, the morphology and the expression pattern of the cells were monitored. Additionally, we analyzed the total sulfated glycosaminoglycan, collagen contents and the expression of the ligament components type I collagen, decorin and tenascin C on protein and for COL1A1, DCN and TNMD on gene level in the spheroids. Subsequently, the cell colonization of polylactide-co-caprolactone [P(LA-CL)] and polydioxanone (PDS) polymer scaffolds was assessed in response to a directed, spheroid-based seeding technique. ACL cells were able to self-assemble spheroids and survive over 14 days. The spheroids decreased in size but not in cellularity depending on the culture time and maintained or even increased their differentiation state. The area of P[LA-CL] scaffolds, colonized after 14 days by the cells of one spheroid, was in average 4.57 ± 2.3 mm(2). Scaffolds consisting of the polymer P[LA-CL] were more suitable for colonization by spheroids than PDS embroideries. We conclude that ACL cell spheroids are suitable as site-directed seeding strategy for scaffolds in ACL tissue engineering approaches and recommend the use of freshly assembled spheroids for scaffold colonization, due to their balanced proliferation and differentiation.

  19. Arcuate ligament of the wrist: normal MR appearance and its relationship to palmar midcarpal instability: a cadaveric study

    International Nuclear Information System (INIS)

    Chang, Weiling; Peduto, Anthony J.; Aguiar, Rodrigo O.C.; Trudell, Debra J.; Resnick, Donald L.

    2007-01-01

    To describe the magnetic resonance (MR) imaging and gross anatomic appearance of the scaphocapitate (SC) ligament and triquetrohamocapitate (THC) ligament, which are the radial and ulnar limbs of the composite arcuate ligament, a critical volar midcarpal stabilizing ligament. T1 spin-echo and 3D gradient-echo MR imaging in the standard, coronal oblique, and axial oblique planes were performed both before and following midcarpal arthrography in seven cadaveric wrists. The seven specimens were then sectioned in selected planes to optimally visualize the SC and THC ligaments. These specimens were analyzed and correlated with their corresponding MR images. The SC and THC ligaments can be visualized in MR images as structures of low signal intensity that form an inverted ''V'' joining the proximal and distal carpal rows. The entire ligamentous complex is best visualized with coronal and axial oblique MR imaging but can also be seen in standard imaging planes. SC and THC ligaments together form the arcuate ligament of the wrist. Their function is crucial to the normal functioning of the wrist. Palmar midcarpal instability (PMCI) is a resulting condition when abnormalities of these ligaments occur. Dedicated MR imaging in the coronal and axial imaging planes can be performed in patients suspected of having PCMI. (orig.)

  20. Arcuate ligament of the wrist: normal MR appearance and its relationship to palmar midcarpal instability: a cadaveric study

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Weiling [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States); Sharp-Grossmont Hospital, Department of Radiology, La Mesa, CA (United States); Peduto, Anthony J. [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States); Westmead Hospital and Western Clinical School of Sydney University, Department of Radiology, Sydney (Australia); Aguiar, Rodrigo O.C. [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States); Universidade Federal do Rio de Janeiro, Rio de Janerio (Brazil); Trudell, Debra J.; Resnick, Donald L. [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States)

    2007-07-15

    To describe the magnetic resonance (MR) imaging and gross anatomic appearance of the scaphocapitate (SC) ligament and triquetrohamocapitate (THC) ligament, which are the radial and ulnar limbs of the composite arcuate ligament, a critical volar midcarpal stabilizing ligament. T1 spin-echo and 3D gradient-echo MR imaging in the standard, coronal oblique, and axial oblique planes were performed both before and following midcarpal arthrography in seven cadaveric wrists. The seven specimens were then sectioned in selected planes to optimally visualize the SC and THC ligaments. These specimens were analyzed and correlated with their corresponding MR images. The SC and THC ligaments can be visualized in MR images as structures of low signal intensity that form an inverted ''V'' joining the proximal and distal carpal rows. The entire ligamentous complex is best visualized with coronal and axial oblique MR imaging but can also be seen in standard imaging planes. SC and THC ligaments together form the arcuate ligament of the wrist. Their function is crucial to the normal functioning of the wrist. Palmar midcarpal instability (PMCI) is a resulting condition when abnormalities of these ligaments occur. Dedicated MR imaging in the coronal and axial imaging planes can be performed in patients suspected of having PCMI. (orig.)

  1. Spiral ligament and stria vascularis changes in cochlear otosclerosis: effect on hearing level.

    Science.gov (United States)

    Doherty, Joni K; Linthicum, Fred H

    2004-07-01

    To investigate the effect of changes within the spiral ligament and stria vascularis on hearing in cochlear otosclerosis, we examined spiral ligament hyalinization, stria vascularis atrophy, and sensory hearing loss in cochlear otosclerosis and described changes in ion transport molecule expression. Retrospective. Tertiary referral center. Thirty-two cochleae from 24 temporal bone donors with histologic evidence of cochlear otosclerosis, including spiral ligament hyalinization. Audiography. Measurements of spiral ligament width, stria vascularis, and bone-conduction thresholds were compared by the amount of hyalinization. Expression of the ion transport molecules Na,K-ATPase, connexin 26, and carbonic anhydrase II were assessed by immunohistochemical techniques. Hyalinization most often involved the posterior basal turn (88%) and the posterior middle turn (27%). Spiral ligament hyalinization correlated significantly with stria vascularis atrophy in the posterior middle turn of the cochlea (rho = -0.63, p Bone-conduction thresholds at 2,000 and 4,000 Hz were significantly associated with the amount of stria vascularis atrophy (rho = -0.44, -0.40, p recycling, resulting in loss of endocochlear potential and sensory hearing loss.

  2. Sonography of the anterior oblique ligament of the trapeziometacarpal joint: a study of cadavers and asymptomatic volunteers.

    Science.gov (United States)

    Chiavaras, Mary M; Harish, Srinivasan; Oomen, Glen; Popowich, Terry; Wainman, Bruce; Bain, James R

    2010-12-01

    The purpose of this study was to evaluate the ability of ultrasound to identify and characterize the anterior oblique ligament of the thumb in cadavers and asymptomatic volunteers. The anterior oblique ligaments of four cadaveric hands were imaged with a high-resolution transducer. The ligaments were then injected with 0.1% methylene blue using ultrasound guidance. To confirm identification of the ligament, the base of the thumb was immediately dissected, revealing the exact location of the dye. The bilateral ligaments in 40 asymptomatic adult volunteers were imaged. Surgical dissection confirmed injection of methylene blue into all cadaveric ligaments. The proximal attachment of the anterior oblique ligament was well defined in all the hands, and the distal attachment was well defined in 94% of the hands. The mean thickness of the anterior oblique ligament at the metacarpal attachment (0.7 mm), midportion (0.98 mm), and trapezial attachment (0.65 mm) did not differ significantly with respect to sex, right and left side, or hand dominance and was weakly correlated with weight, height, body mass index, and age. The length of the ligament was statistically significantly different between the dominant (10.6 mm) and nondominant (9.6 mm) hands. The volar metacarpal translation with palmar abduction stress did not differ significantly between the dominant (0.7 mm) and nondominant (0.8 mm) hands. There was no association between the degree of translation and the biologic characteristics (weight, height, body mass index, and age). High-resolution ultrasound can be used to identify and measure the thickness of the anterior oblique ligament. Dynamic ultrasound imaging can depict volar translation of the metacarpal, which may facilitate diagnosis of ligamentous injury.

  3. Understanding acute ankle ligamentous sprain injury in sports

    Directory of Open Access Journals (Sweden)

    Fong Daniel TP

    2009-07-01

    Full Text Available Abstract This paper summarizes the current understanding on acute ankle sprain injury, which is the most common acute sport trauma, accounting for about 14% of all sport-related injuries. Among, 80% are ligamentous sprains caused by explosive inversion or supination. The injury motion often happens at the subtalar joint and tears the anterior talofibular ligament (ATFL which possesses the lowest ultimate load among the lateral ligaments at the ankle. For extrinsic risk factors to ankle sprain injury, prescribing orthosis decreases the risk while increased exercise intensity in soccer raises the risk. For intrinsic factors, a foot size with increased width, an increased ankle eversion to inversion strength, plantarflexion strength and ratio between dorsiflexion and plantarflexion strength, and limb dominance could increase the ankle sprain injury risk. Players with a previous sprain history, players wearing shoes with air cells, players who do not stretch before exercising, players with inferior single leg balance, and overweight players are 4.9, 4.3, 2.6, 2.4 and 3.9 times more likely to sustain an ankle sprain injury. The aetiology of most ankle sprain injuries is incorrect foot positioning at landing – a medially-deviated vertical ground reaction force causes an explosive supination or inversion moment at the subtalar joint in a short time (about 50 ms. Another aetiology is the delayed reaction time of the peroneal muscles at the lateral aspect of the ankle (60–90 ms. The failure supination or inversion torque is about 41–45 Nm to cause ligamentous rupture in simulated spraining tests on cadaver. A previous case report revealed that the ankle joint reached 48 degrees inversion and 10 degrees internal rotation during an accidental grade I ankle ligamentous sprain injury during a dynamic cutting trial in laboratory. Diagnosis techniques and grading systems vary, but the management of ankle ligamentous sprain injury is mainly conservative

  4. Incorporating ligament laxity in a finite element model for the upper cervical spine.

    Science.gov (United States)

    Lasswell, Timothy L; Cronin, Duane S; Medley, John B; Rasoulinejad, Parham

    2017-11-01

    Predicting physiological range of motion (ROM) using a finite element (FE) model of the upper cervical spine requires the incorporation of ligament laxity. The effect of ligament laxity can be observed only on a macro level of joint motion and is lost once ligaments have been dissected and preconditioned for experimental testing. As a result, although ligament laxity values are recognized to exist, specific values are not directly available in the literature for use in FE models. The purpose of the current study is to propose an optimization process that can be used to determine a set of ligament laxity values for upper cervical spine FE models. Furthermore, an FE model that includes ligament laxity is applied, and the resulting ROM values are compared with experimental data for physiological ROM, as well as experimental data for the increase in ROM when a Type II odontoid fracture is introduced. The upper cervical spine FE model was adapted from a 50th percentile male full-body model developed with the Global Human Body Models Consortium (GHBMC). FE modeling was performed in LS-DYNA and LS-OPT (Livermore Software Technology Group) was used for ligament laxity optimization. Ordinate-based curve matching was used to minimize the mean squared error (MSE) between computed load-rotation curves and experimental load-rotation curves under flexion, extension, and axial rotation with pure moment loads from 0 to 3.5 Nm. Lateral bending was excluded from the optimization because the upper cervical spine was considered to be primarily responsible for flexion, extension, and axial rotation. Based on recommendations from the literature, four varying inputs representing laxity in select ligaments were optimized to minimize the MSE. Funding was provided by the Natural Sciences and Engineering Research Council of Canada as well as GHMBC. The present study was funded by the Natural Sciences and Engineering Research Council of Canada to support the work of one graduate student

  5. A low-level diode laser therapy reduces the lipopolysaccharide (LPS)-induced periodontal ligament cell inflammation

    International Nuclear Information System (INIS)

    Huang, T H; Chen, C C; Liu, S L; Lu, Y C; Kao, C T

    2014-01-01

    The purpose of this study was to investigate the cytologic effects of inflammatory periodontal ligament cells in vitro after low-level laser therapy. Human periodontal ligament cells were cultured, exposed to lipopolysaccharide and subjected to low-level laser treatment of 5 J cm −2 or 10 J cm −2 using a 920 nm diode laser. A periodontal ligament cell attachment was observed under a microscope, and the cell viability was quantified by a mitochondrial colorimetric assay. Lipopolysaccharide-treated periodontal ligament cells were irradiated with the low-level laser, and the expression levels of several inflammatory markers, iNOS, TNF-α and IL-1, and pErk kinase, were analyzed by reverse transcription polymerase chain reaction and western blot. The data were collected and analyzed by one-way analysis of variance; p < 0.05 indicated a statistically significant difference. The low-level laser treatment of periodontal ligament cells increased their ability to attach and survive. After irradiation, the expression levels of iNOS, TNF-α and IL-1 in lipopolysaccharide-exposed periodontal ligament cells decreased over time (p < 0.05). In periodontal ligament cells, low-level diode laser treatment increased the cells’ proliferative ability and decreased the expression of the examined inflammatory mediators. (letters)

  6. Acute neck pain caused by pseudogout attack of calcified cervical yellow ligament: a case report.

    Science.gov (United States)

    Kobayashi, Takashi; Miyakoshi, Naohisa; Abe, Toshiki; Abe, Eiji; Kikuchi, Kazuma; Noguchi, Hideaki; Konno, Norikazu; Shimada, Yoichi

    2016-05-30

    Calcification of the yellow ligament sometimes compresses the spinal cord and can induce myelopathy. Usually, the calcification does not induce acute neck pain. We report a case of a patient with acute neck pain caused by calcium pyrophosphate dihydrate in a calcified cervical yellow ligament. A 70-year-old Japanese woman presented with acute neck pain. She had a moderately high fever (37.5 °C), and her neck pain was so severe that she could not move her neck in any direction. Computed tomography showed a high-density area between the C5 and C6 laminae suspicious for calcification of the yellow ligament. Magnetic resonance imaging showed intermediate-signal intensity on T1-weighted imaging and high-signal intensity on T2-weighted imaging surrounding a low-signal region on both T1- and T2-weighted imaging with cord compression. There was a turbid, yellow fluid collection in the yellow ligament at the time of operation. Histologically, calcium pyrophosphate dihydrate crystals were found in the fluid, and she was diagnosed as having a pseudogout attack of the yellow ligament. Pseudogout attack of the cervical yellow ligament is rare, but this clinical entity should be added to the differential diagnosis of acute neck pain, especially when calcification of the yellow ligament exists.

  7. Engineering tendon and ligament tissues: present developments towards successful clinical products.

    Science.gov (United States)

    Rodrigues, Márcia T; Reis, Rui L; Gomes, Manuela E

    2013-09-01

    Musculoskeletal diseases are one of the leading causes of disability worldwide. Among them, tendon and ligament injuries represent an important aspect to consider in both athletes and active working people. Tendon and ligament damage is an important cause of joint instability, and progresses into early onset of osteoarthritis, pain, disability and eventually the need for joint replacement surgery. The social and economical burden associated with these medical conditions presents a compelling argument for greater understanding and expanding research on this issue. The particular physiology of tendons and ligaments (avascular, hypocellular and overall structural mechanical features) makes it difficult for currently available treatments to reach a complete and long-term functional repair of the damaged tissue, especially when complete tear occurs. Despite the effort, the treatment modalities for tendon and ligament are suboptimal, which have led to the development of alternative therapies, such as the delivery of growth factors, development of engineered scaffolds or the application of stem cells, which have been approached in this review. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    Science.gov (United States)

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Sheet, ligament and droplet formation in swirling primary atomization

    Directory of Open Access Journals (Sweden)

    Changxiao Shao

    2018-04-01

    Full Text Available We report direct numerical simulations of swirling liquid atomization to understand the physical mechanism underlying the sheet breakup of a non-turbulent liquid swirling jet which lacks in-depth investigation. The volume-of-fluid (VOF method coupled with adapted mesh refinement (AMR technique in GERRIS code is employed in the present simulation. The mechanisms of sheet, ligament and droplet formation are investigated. It is observed that the olive-shape sheet structure is similar to the experimental result qualitatively. The numerical results show that surface tension, pressure difference and swirling effect contribute to the contraction and extension of liquid sheet. The ligament formation is partially at the sheet rim or attributed to the extension of liquid hole. Especially, the movement of hairpin vortex exerts by an anti-radial direction force to the sheet surface and leads to the sheet thinness. In addition, droplet formation is attributed to breakup of ligament and central sheet.

  10. Sheet, ligament and droplet formation in swirling primary atomization

    Science.gov (United States)

    Shao, Changxiao; Luo, Kun; Chai, Min; Fan, Jianren

    2018-04-01

    We report direct numerical simulations of swirling liquid atomization to understand the physical mechanism underlying the sheet breakup of a non-turbulent liquid swirling jet which lacks in-depth investigation. The volume-of-fluid (VOF) method coupled with adapted mesh refinement (AMR) technique in GERRIS code is employed in the present simulation. The mechanisms of sheet, ligament and droplet formation are investigated. It is observed that the olive-shape sheet structure is similar to the experimental result qualitatively. The numerical results show that surface tension, pressure difference and swirling effect contribute to the contraction and extension of liquid sheet. The ligament formation is partially at the sheet rim or attributed to the extension of liquid hole. Especially, the movement of hairpin vortex exerts by an anti-radial direction force to the sheet surface and leads to the sheet thinness. In addition, droplet formation is attributed to breakup of ligament and central sheet.

  11. Review of common conditions associated with periodontal ligament widening

    Energy Technology Data Exchange (ETDEWEB)

    Mortazavi, Hamed; Baharvand, Maryam [Dept. of Oral Medicine, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    The aim of this article is to review a group of lesions associated with periodontal ligament (PDL) widening. An electronic search was performed using specialized databases such as Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus to find relevant studies by using keywords such as “periodontium”, “periodontal ligament”, “periodontal ligament space”, “widened periodontal ligament”, and “periodontal ligament widening”. Out of nearly 200 articles, about 60 were broadly relevant to the topic. Ultimately, 47 articles closely related to the topic of interest were reviewed. When the relevant data were compiled, the following 10 entities were identified: occlusal/orthodontic trauma, periodontal disease/periodontitis, pulpo-periapical lesions, osteosarcoma, chondrosarcoma, non-Hodgkin lymphoma, progressive systemic sclerosis, radiation-induced bone defect, bisphosphonate-related osteonecrosis, and osteomyelitis. Although PDL widening may be encountered by many dentists during their routine daily procedures, the clinician should consider some serious related conditions as well.

  12. Review of common conditions associated with periodontal ligament widening

    International Nuclear Information System (INIS)

    Mortazavi, Hamed; Baharvand, Maryam

    2016-01-01

    The aim of this article is to review a group of lesions associated with periodontal ligament (PDL) widening. An electronic search was performed using specialized databases such as Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus to find relevant studies by using keywords such as “periodontium”, “periodontal ligament”, “periodontal ligament space”, “widened periodontal ligament”, and “periodontal ligament widening”. Out of nearly 200 articles, about 60 were broadly relevant to the topic. Ultimately, 47 articles closely related to the topic of interest were reviewed. When the relevant data were compiled, the following 10 entities were identified: occlusal/orthodontic trauma, periodontal disease/periodontitis, pulpo-periapical lesions, osteosarcoma, chondrosarcoma, non-Hodgkin lymphoma, progressive systemic sclerosis, radiation-induced bone defect, bisphosphonate-related osteonecrosis, and osteomyelitis. Although PDL widening may be encountered by many dentists during their routine daily procedures, the clinician should consider some serious related conditions as well

  13. Anatomy and histology of apical support: a literature review concerning cardinal and uterosacral ligaments.

    Science.gov (United States)

    Ramanah, Rajeev; Berger, Mitchell B; Parratte, Bernard M; DeLancey, John O L

    2012-11-01

    The objective of this work was to collect and summarize relevant literature on the anatomy, histology, and imaging of apical support of the upper vagina and the uterus provided by the cardinal (CL) and uterosacral (USL) ligaments. A literature search in English, French, and German languages was carried out with the keywords apical support, cardinal ligament, transverse cervical ligament, Mackenrodt ligament, parametrium, paracervix, retinaculum uteri, web, uterosacral ligament, and sacrouterine ligament in the PubMed database. Other relevant journal and textbook articles were sought by retrieving references cited in previous PubMed articles. Fifty references were examined in peer-reviewed journals and textbooks. The USL extends from the S2 to the S4 vertebra region to the dorsal margin of the uterine cervix and/or to the upper third of the posterior vaginal wall. It has a superficial and deep component. Autonomous nerve fibers are a major constituent of the deep USL. CL is defined as a perivascular sheath with a proximal insertion around the origin of the internal iliac artery and a distal insertion on the cervix and/or vagina. It is divided into a cranial (vascular) and a caudal (neural) portions. Histologically, it contains mainly vessels, with no distinct band of connective tissue. Both the deep USL and the caudal CL are closely related to the inferior hypogastric plexus. USL and CL are visceral ligaments, with mesentery-like structures containing vessels, nerves, connective tissue, and adipose tissue.

  14. Ligamentous and capsular restraints to experimental posterior elbow joint dislocation

    DEFF Research Database (Denmark)

    Deutch, S.R.; Olsen, B.S.; Jensen, S.L.

    2003-01-01

    the anterior capsule and the lateral collateral ligament complex (LCLC), whereas in the flexed elbow the anterior capsule did not have a stabilizing effect. In flexed joint positions, the LCLC seems to be the only immediate stabilizer against PEFR, and thereby against posterolateral instability and possibly...... against posterior dislocation. The medial collateral ligament did not have any immediate stabilizing effect, but it prevented the final step of the posterior dislocation....

  15. MR imaging of the lateral collateral ligaments after ankle sprain

    International Nuclear Information System (INIS)

    Grebe, P.; Kreitner, K.F.; Roeder, W.; Kersjes, W.; Hennes, R.; Runkel, M.

    1995-01-01

    35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [de

  16. Achondroplasia manifesting as enchondromatosis and ossification of the spinal ligaments: a case report

    Directory of Open Access Journals (Sweden)

    Al Kaissi Ali

    2008-08-01

    Full Text Available Abstract Introduction A girl presented with achondroplasia manifested as mild knee pain associated with stiffness of her back. A skeletal survey showed enchondroma-like metaphyseal dysplasia and ossification of the spinal ligaments. Magnetic resonance imaging of the spine further clarified the pathological composites. Case presentation A 7-year-old girl presented with the classical phenotypic features of achondroplasia. Radiographic documentation showed the co-existence of metaphyseal enchondromatosis and development of spinal bony ankylosis. Magnetic resonance imaging showed extensive ossification of the anterior and posterior spinal ligaments. Additional features revealed by magnetic resonance imaging included calcification of the peripheral vertebral bodies associated with anterior end-plate irregularities. Conclusion Enchondromas are metabolically active and may continue to grow and evolve throughout the patient's lifetime; thus, progressive calcification over a period of years is not unusual. Ossification of the spinal ligaments has a specific site of predilection and often occurs in combination with senile ankylosing vertebral hyperostosis. Nevertheless, ossification of the spinal ligaments has been encountered in children with syndromic malformation complex. It is a multifactorial disease in which complex genetic and environmental factors interact, potentially leading to chronic pressure on the spinal cord and nerve roots with subsequent development of myeloradiculopathy. Our patient presented with a combination of achondroplasia, enchondroma-like metaphyseal dysplasia and calcification of the spinal ligaments. We suggest that the development of heterotopic bone formation along the spinal ligaments had occurred through an abnormal ossified enchondral mechanism. We postulate that ossification of the spinal ligaments and metaphyseal enchondromatous changes are related to each other and represent impaired terminal differentiation of

  17. Dynamic high-resolution ultrasound of intrinsic and extrinsic ligaments of the wrist: How to make it simple.

    Science.gov (United States)

    Gitto, Salvatore; Messina, Carmelo; Mauri, Giovanni; Aliprandi, Alberto; Sardanelli, Francesco; Sconfienza, Luca Maria

    2017-02-01

    Wrist ligaments are crucial structures for the maintenance of carpal stability. They are classified into extrinsic ligaments, connecting the carpus with the forearm bones or distal radioulnar ligaments, and intrinsic ligaments, entirely situated within the carpus. Lesions of intrinsic and extrinsic ligaments of the wrist have been demonstrated to occur largely, mostly in patients with history of trauma and carpal instability, or rheumatoid arthritis. Ultrasound allows for rapid, cost-effective, non-invasive and dynamic evaluation of the wrist, and may represent a valuable diagnostic tool. Although promising results have been published, ultrasound of wrist ligaments is not performed in routine clinical practice, maybe due to its technical feasibility regarded as quite complex. This review article aims to enlighten readers about the normal sonographic appearance of intrinsic and extrinsic carpal ligaments, and describe a systematic approach for their sonographic assessment with detailed anatomic landmarks, dynamic manoeuvres and scanning technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Effects of Different Angles of the Traction Table on Lumbar Spine Ligaments: A Finite Element Study.

    Science.gov (United States)

    Farajpour, Hekmat; Jamshidi, Nima

    2017-12-01

    The traction bed is a noninvasive device for treating lower back pain caused by herniated intervertebral discs. In this study, we investigated the impact of the traction bed on the lower back as a means of increasing the disc height and creating a gap between facet joints. Computed tomography (CT) images were obtained from a female volunteer and a three-dimensional (3D) model was created using software package MIMICs 17.0. Afterwards, the 3D model was analyzed in an analytical software (Abaqus 6.14). The study was conducted under the following traction loads: 25%, 45%, 55%, and 85% of the whole body weight in different angles. Results indicated that the loading angle in the L3-4 area had 36.8%, 57.4%, 55.32%, 49.8%, and 52.15% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 32.3%, 10.6%, 53.4%, 56.58%, and 57.35%. Also, the body weight had 63.2%, 42.6%, 44.68%, 50.2%, and 47.85% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 67.7%, 89.4%, 46.6%, 43.42% and 42.65%. The authenticity of results was checked by comparing with the experimental data. The results show that traction beds are highly effective for disc movement and lower back pain relief. Also, an optimal angle for traction can be obtained in a 3D model analysis using CT or magnetic resonance imaging images. The optimal angle would be different for different patients and thus should be determined based on the decreased height of the intervertebral disc, weight and height of patients.

  19. Dynamic high-resolution ultrasound of intrinsic and extrinsic ligaments of the wrist: How to make it simple

    International Nuclear Information System (INIS)

    Gitto, Salvatore; Messina, Carmelo; Mauri, Giovanni; Aliprandi, Alberto; Sardanelli, Francesco; Sconfienza, Luca Maria

    2017-01-01

    Highlights: • US allows for rapid, cost-effective, and non-invasive assessment of wrist ligaments. • Knowledge of landmarks and dynamic manoeuvres is basic for a systematic examination. • A sequential approach is effective, timesaving and feasible in clinical practice. - Abstract: Wrist ligaments are crucial structures for the maintenance of carpal stability. They are classified into extrinsic ligaments, connecting the carpus with the forearm bones or distal radioulnar ligaments, and intrinsic ligaments, entirely situated within the carpus. Lesions of intrinsic and extrinsic ligaments of the wrist have been demonstrated to occur largely, mostly in patients with history of trauma and carpal instability, or rheumatoid arthritis. Ultrasound allows for rapid, cost-effective, non-invasive and dynamic evaluation of the wrist, and may represent a valuable diagnostic tool. Although promising results have been published, ultrasound of wrist ligaments is not performed in routine clinical practice, maybe due to its technical feasibility regarded as quite complex. This review article aims to enlighten readers about the normal sonographic appearance of intrinsic and extrinsic carpal ligaments, and describe a systematic approach for their sonographic assessment with detailed anatomic landmarks, dynamic manoeuvres and scanning technique.

  20. Dynamic high-resolution ultrasound of intrinsic and extrinsic ligaments of the wrist: How to make it simple

    Energy Technology Data Exchange (ETDEWEB)

    Gitto, Salvatore, E-mail: sal.gitto@gmail.com [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano (Italy); Messina, Carmelo [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano (Italy); Mauri, Giovanni [Servizio di Radiologia, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese (Italy); Dipartimento di Radiologia Interventistica, Istituto Europeo di Oncologia, Via Ripamonti 435, 20141 Milano (Italy); Aliprandi, Alberto [Servizio di Radiologia, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese (Italy); Sardanelli, Francesco [Servizio di Radiologia, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20133 Milano (Italy); Sconfienza, Luca Maria [Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20133 Milano (Italy); Unità Operativa di Radiologia/Diagnostica per Immagini con Servizio di Radiologia Interventistica, IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161 Milano (Italy)

    2017-02-15

    Highlights: • US allows for rapid, cost-effective, and non-invasive assessment of wrist ligaments. • Knowledge of landmarks and dynamic manoeuvres is basic for a systematic examination. • A sequential approach is effective, timesaving and feasible in clinical practice. - Abstract: Wrist ligaments are crucial structures for the maintenance of carpal stability. They are classified into extrinsic ligaments, connecting the carpus with the forearm bones or distal radioulnar ligaments, and intrinsic ligaments, entirely situated within the carpus. Lesions of intrinsic and extrinsic ligaments of the wrist have been demonstrated to occur largely, mostly in patients with history of trauma and carpal instability, or rheumatoid arthritis. Ultrasound allows for rapid, cost-effective, non-invasive and dynamic evaluation of the wrist, and may represent a valuable diagnostic tool. Although promising results have been published, ultrasound of wrist ligaments is not performed in routine clinical practice, maybe due to its technical feasibility regarded as quite complex. This review article aims to enlighten readers about the normal sonographic appearance of intrinsic and extrinsic carpal ligaments, and describe a systematic approach for their sonographic assessment with detailed anatomic landmarks, dynamic manoeuvres and scanning technique.

  1. Allograft tendon reconstruction of the anterior talofibular ligament and calcaneofibular Ligament in the treatment of chronic ankle instability.

    Science.gov (United States)

    Wang, Weikai; Xu, Guo Hong

    2017-04-08

    The purpose was retrospectively to investigate functional and clinical outcomes after anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) reconstruction using a single allograft. Patients with severe chronic lateral instability of the ankle underwent surgery after conservative treatment failed. Ultrasounds of the ankle were performed, and if the AFTL and CFL were completely torn without enough soft tissue for repair, the ligaments were reconstructed using allograft tendon. Outcomes were assessed by clinical examination, stress radiography, ultrasound, the American Orthopaedic Foot and Ankle Society score (AOFAS), and Karlsson Ankle Functional score (KAFS) before surgery and at final follow-up. Nineteen patients, ten men and nine women with mean age of 27.9 years (range, 19-41 years), underwent reconstruction. Mean follow-up was 30 months (range, 24-40 months). At final follow-up, all patients had returned to activity without instability, pain, or limited range of motion. On stress radiography, mean talar tilt angle decreased from 17.32° ± 3.58° before surgery to 4.16° ± 1.12° at follow-up (p surgery to 3.97 ± 0.99 mm at follow-up (p < 0.05). Mean AOFAS improved from 64.00 ± 18.43 to 90.32 ± 5.17 points (p < 0.001), and mean KAFS improved from 50.84 ± 16.73 to 90.89 ± 5.08 points (p < 0.001). Ultrasound showed the reconstructed ligaments maintained good continuity and excellent tension. No case of infection and immunological rejection was reported. This novel reconstruction technique takes into account the anatomical specialty of AFTL and CFL. This case series showed increased stability of the ankle in clinical and functional outcomes. The trial registration number (TRN) and date of registration: ChiCTR-ORC-17010796 , Mar 6th 2017. Retrospectively registered.

  2. Alterations of the transverse ligament: an MRI study comparing patients with acute whiplash and matched control subjects.

    Science.gov (United States)

    Ulbrich, Erika Jasmin; Eigenheer, Sandra; Boesch, Chris; Hodler, Juerg; Busato, André; Schraner, Christian; Anderson, Suzanne E; Bonel, Harald; Zimmermann, Heinz; Sturzenegger, Matthias

    2011-10-01

    The objective of our study was to evaluate whether there is injury to the transverse ligament of the atlas in patients with acute whiplash. Ninety patients with an acute (transverse ligament was measured on midsagittal T1 volumetric interpolated breath-hold examination (VIBE) images and transverse reformatted VIBE images. The signal intensity of the transverse ligament was measured on transverse STIR images and on transverse reformatted T1 VIBE images before and after IV administration of gadoterate. Contrast between the transverse ligament and CSF and alterations of contrast after gadoterate injection were calculated. Patients had a minimally thicker transverse ligament (posttraumatic swelling) than control subjects, and the difference in thickness was significant in men only (p = 0.03). In patients, a significant signal alteration of the transverse ligament (p = 0.03) was seen on STIR (posttraumatic edema) and native VIBE sequences. The contrast between the transverse ligament and the CSF on VIBE images was significantly (p = 0.005) lower in patients than in control subjects. With the application of a contrast agent, the contrast difference between the transverse ligament and CSF in patients and control subjects was less pronounced (p = 0.038). There was no abnormal uptake of contrast agent by the transverse ligament or CSF. The results of our study indicate possible involvement of the transverse ligament in whiplash injury. Although MRI may be helpful to study injury-related changes of anatomic structures in cohorts, it is not suited for individual diagnosis because the alterations are too small.

  3. Aynı Coğrafyada İki Savaş: Troia ve Çanakkale Savaşlarının Karşılaştırılması

    OpenAIRE

    Reyhan Körpe

    2015-01-01

    Yaklaşık üç bin yıl arayla aynı topraklarda meydana gelen iki savaş, Troia ve Çanakkale Savaşları sadece coğrafi benzerlikleri değil, nedenleri, oluş şekli ve sonuçları ile birbirine benzemektedir. Birinci Dünya savaşının bir parçası olan Çanakkale Savaşı gibi, arkeolojik kaynaklar Homeros’un destanlaştırdığı Troia Savaşı’nın Tunç Çağların sonunda Batı Anadolu’daki çok büyük bir mücadelenin parçası olduğunu ortaya koymuştur. Çanakkale Savaşları sırasında kullanılan yöntemlerin antik çağ savaş...

  4. A stress MRI of the shoulder for evaluation of ligamentous stabilizers in acute and chronic acromioclavicular joint instabilities.

    Science.gov (United States)

    Izadpanah, Kaywan; Winterer, Jan; Vicari, Marco; Jaeger, Martin; Maier, Dirk; Eisebraun, Leonie; Ute Will, Jutta; Kotter, Elmar; Langer, Mathias; Südkamp, Norbert P; Hennig, Jürgen; Weigel, Mathias

    2013-06-01

    To show the feasibility of a stress magnetic resonance imaging (MRI) as a new method for simultaneous evaluation of the morphology and the functional integrity of the acromioclavicular joint (ACJ) ligamentous stabilizers. MRI of four volunteers, 10 patients with acute, and six with chronic ACJ injuries was performed using a 0.25 T open MRI scanner. A 2D-proton-density and a 3D-gradient-echo sequence at rest and under 6.5 kg shoulder traction were performed. Comparative measurements of the coracoclavicular and the acromioclavicular distance were performed. Additionally, the conoid and trapezoid ligament lengths were measured with multiplanar reconstructions. MRI at rest correctly identified tears of the coracoclavicular and the acromioclavicular ligaments in eight patients suffering acute ACJ injuries. Stress application helped to distinguish between partial and complete coracoclavicular ligament tears in two cases. Insufficiency of the ACJ ligaments was present in all acute and chronic ACJ injuries. Stress application in chronic ACJ ligaments revealed isolated insufficiency of the conoid ligament in three cases and of the trapezoid ligament in one case. Combined insufficiency was present in two cases. Stress MRI facilitates simultaneous acquisition of morphologic and functional information of the ACJ stabilizers. In acute ACJ injuries it helps to distinguish between partial and complete ligament tears. In chronic ACJ injuries it provides functional information of the ligament regrinds. Copyright © 2012 Wiley Periodicals, Inc.

  5. Arthrographic diagnosis of ruptured calcaneofibular ligament. I

    International Nuclear Information System (INIS)

    Vuust, M.

    1980-01-01

    A new projection, oblique axial, is recommended for the arthrography of the acute sprained ankle for the correct diagnosis of a ruptured calcaneofibular ligament. Its value is experimentally confirmed. (Auth.)

  6. The Use of Canine Stifle Orthotics for Cranial Cruciate Ligament Insufficiency

    Directory of Open Access Journals (Sweden)

    Brittany Jean Carr

    2016-01-01

    Full Text Available Objective: To assess weight bearing of dogs treated for unilateral cranial cruciate ligament insufficiency with a custom stifle orthotic.Background: Cranial cruciate ligament (CCL insufficiency is the most common cause of hind limb lameness in dogs. While there are numerous options for surgical management, surgery is not always an option. Recently, the use of canine stifle orthotics has also emerged as a means to non-surgically manage patients with cranial cruciate ligament insufficiency.  Evidentiary value:  This is a retrospective study of ten dogs treated for unilateral cranial cruciate ligament rupture with a stifle orthotic.Methods: Medical records (January 2005- December 2012 of ten dogs treated for unilateral cranial cruciate ligament rupture with a stifle orthotic were reviewed.  Temporospatial gait analysis was performed using a pressure sensing walkway at baseline and 90 days or greater post orthotic placement to identify weight bearing with total pressure index % (TPI%.Results: TPI% improved significantly by 5.1% in the affected limb when compared to baseline (p = 0.0020. At final gait analysis, TPI% significantly improved by 3% in the affected limb with the orthotic off when compared to the unaffected limb (p = 0.0020.Conclusion: Custom canine stifle orthotics allow for improved weight bearing in the affected limb.Application: Custom canine stifle orthotics should be considered for cases with concurrent medical conditions or financial constraints that do not allow for surgical intervention.

  7. Proteomic differences between native and tissue‐engineered tendon and ligament

    Science.gov (United States)

    Tew, Simon R.; Peffers, Mandy; Canty‐Laird, Elizabeth G.; Comerford, Eithne

    2016-01-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age‐related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin‐based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular‐associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. PMID:27080496

  8. A postmenopausal woman with sciatica from broad ligament leiomyoma: a case report.

    Science.gov (United States)

    Tsai, Ya-Chu May

    2016-10-31

    Unilateral lower abdominal pain and/or sciatic nerve pain is a common presentation in the elderly population. The prevalence of broad ligament leiomyoma is leiomyomas to be clinically significant. Thus, we highlight a case of symptomatic broad ligament leiomyoma in a postmenopausal woman whose symptoms improved after definitive treatment. A 62-year-old postmenopausal Macedonian woman was referred to our gynecological department with unexplained pain in her left leg and left iliac fossa region on walking. There was minimal relief with increasing analgesia use prescribed by the family physician. Investigations revealed an ipsilateral adnexal mass and subsequent treatment with laparoscopic broad ligament myomectomy helped to alleviate her symptoms. Our case highlights the importance of staying mindful of alternate diagnoses when presented with a common presentation of iliac fossa pain and pain in the leg. Although broad ligament leiomyomas are benign tumors, the uncommon symptomatic presentation led us to report and focus some attention on this type of tumor.

  9. Sources of adult mesenchymal stem cells for ligament and tendon tissue engineering.

    Science.gov (United States)

    Dhinsa, Baljinder S; Mahapatra, Anant N; Khan, Wasim S

    2015-01-01

    Tendon and ligament injuries are common, and repair slowly with reduced biomechanical properties. With increasing financial demands on the health service and patients to recover from tendon and ligament injuries faster, and with less morbidity, health professionals are exploring new treatment options. Tissue engineering may provide the answer, with its unlimited source of natural cells that in the correct environment may improve repair and regeneration of tendon and ligament tissue. Mesenchymal stem cells have demonstrated the ability to self renew and have multilineage differentiation potential. The use of bone marrow-derived mesenchymal stem cells has been reported, however significant in vitro culture expansion is required due to the low yield of cells, which has financial implications. Harvesting of bone marrow cells also has associated morbidity. Several studies have looked at alternative sources for mesenchymal stem cells. Reports in literature from animal studies have been encouraging, however further work is required. This review assesses the potential sources of mesenchymal stem cells for tissue engineering in tendons and ligaments.

  10. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Directory of Open Access Journals (Sweden)

    Jung Ho-Joong

    2009-05-01

    Full Text Available Abstract Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to

  11. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Science.gov (United States)

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to

  12. Axial oblique MR imaging of the intrinsic ligaments of the wrist: initial experience

    International Nuclear Information System (INIS)

    Robinson, G.; Chung, T.; Finlay, K.; Friedman, L.

    2006-01-01

    To evaluate two separate MR sequences acquired in the axial oblique plane, parallel to the long axis of the scapholunate (SL) and lunotriquetral (LT) ligaments, to determine whether the addition of these sequences to the standard MR wrist examination improves visualization of the intrinsic ligaments, and the evaluation of their integrity. To our knowledge, this plane has not been described in the literature previously. In total we evaluated 26 patients with chronic wrist pain or instability, referred for MR imaging following assessment by an orthopedic surgeon or physiatrist. All patients underwent initial conventional tri-compartment wrist arthrography, which served as the reference standard. This was immediately followed by MR arthrography, in the standard coronal and true axial planes, as well as in the axial oblique plane. The SL and LT ligaments were initially assessed for the presence or absence of tear, using the standard coronal and true axial sequences, and subsequently re-evaluated with the addition of the axial oblique planes. A total of ten intrinsic ligament tears were identified with conventional arthrography: six SL and four LT tears. Five of the six SL tears were identified on the standard sequences. All six were diagnosed with the addition of the oblique sequences. There were three false-positive SL tears identified using standard MR imaging, and two false-positives with the addition of the oblique sequences. No LT tear was identified on standard sequences, whereas all four were confidently seen with the addition of oblique images. No false-positives of the LT ligament were recorded with either standard or axial oblique sequences. The study suggests that the addition of axial oblique MR sequences helps identify tears to the intrinsic ligaments of the wrist, particularly the LT ligament. In addition, the axial oblique images assist in localization of the tear. (orig.)

  13. Intrathecal ligaments and nerve root tension: possible sources of lumbar pain during spaceflight.

    Science.gov (United States)

    Kershner, David; Binhammer, Robert

    2004-04-01

    Lumbar intrathecal ligaments have recently been demonstrated to randomly bind dorsal nerve roots to the dura within the lumbar vertebral column. Lengthening of the vertebral column and associated lumbar back pain experienced by astronauts is common in microgravity. This study was designed to investigate the relationship of lumbar intrathecal ligaments in spinal lengthening as a possible mechanism for back pain. A two-part study was designed using 36 vertebral columns from embalmed cadavers. There were 12 vertebral columns studied in mid-sagittal section to demonstrate the possible movement of the spinal cord during lengthening of the vertebral column. The remainder were assessed for the amount of tension placed on a dorsal nerve root by the lumbar intrathecal ligament during lengthening of the vertebral column. The spinal cord moves in a cephalic direction approximately 2.8 mm with 4 cm lengthening of the vertebral column. During lengthening, a loss of thoracic and lordotic curvature was noted with an increase in disk height. Tension was significantly increased on the dorsal nerve roots being tethered by the lumbar intrathecal ligaments in comparison to non-tethered nerve roots during lengthening of the vertebral column. A significant amount of tension is placed on dorsal nerve roots tethered by intrathecal ligaments within the lumbar spine during spinal lengthening. These ligaments randomly bind dorsal nerve roots in the lumbar spine and may be involved in the back pain experienced by astronauts in microgravity.

  14. MR Analysis of the Transverse Ligament in the Late Stage of Whiplash Injury

    Energy Technology Data Exchange (ETDEWEB)

    Krakenes, J.; Nordli, H.; Moen, G. [Haukeland Univ. Hospital, Bergen (Norway). Section of Neuroradiology; Kaale, B.R. [Firda Medical Center, Sandane (Norway); Rorvik, J. [Haukeland Univ. Hospital, Bergen (Norway). Dept. of Radiology; Gilhus, N.E. [Haukeland Univ. Hospital, Bergen (Norway). Dept. of Neurology

    2003-11-01

    Purpose: To analyse and classify structural changes in the transverse ligament in the late stage of whiplash injury by use of high-resolution MRI, and to evaluate the reliability of our classification. Material and Methods: Ninety-two whiplash-injured (2-9 years previously, mean 6 years) and 30 non-injured individuals underwent proton-weighted MR imaging of the craniovertebral junction in three orthogonal planes. Structural changes in the transverse ligaments were graded twice (grades 1-3) based on increased signal, independently by 3 radiologists with a 4-month interval. Inter- and intraobserver statistics were calculated by ordinary and weighted kappa (K). Results: Image quality was excellent in 109 cases and slightly reduced in 13. Twenty-two out of 30 ligaments in the control group were classified as normal (73%) compared with only 32 out of 92 in the injured group (36%). Two or all 3 observers agreed in their grading in 101 out of 122 ligaments (83%). Intraobserver agreement (weighted K) was fair to good (0.33-0.73). Pair-wise interobserver agreement was fair (0.24-0.39). Reasons for divergent grading were insufficient knowledge of normal variations, low signal intensity in the peridental soft tissue obscuring the ligament and interpretation flaw. Conclusion: Whiplash trauma can damage the transverse ligament. By use of high-resolution proton-weighted MR images such lesions can be detected and classified. The reliability of this classification still needs improvement.

  15. MR Analysis of the Transverse Ligament in the Late Stage of Whiplash Injury

    International Nuclear Information System (INIS)

    Krakenes, J.; Nordli, H.; Moen, G.; Rorvik, J.; Gilhus, N.E.

    2003-01-01

    Purpose: To analyse and classify structural changes in the transverse ligament in the late stage of whiplash injury by use of high-resolution MRI, and to evaluate the reliability of our classification. Material and Methods: Ninety-two whiplash-injured (2-9 years previously, mean 6 years) and 30 non-injured individuals underwent proton-weighted MR imaging of the craniovertebral junction in three orthogonal planes. Structural changes in the transverse ligaments were graded twice (grades 1-3) based on increased signal, independently by 3 radiologists with a 4-month interval. Inter- and intraobserver statistics were calculated by ordinary and weighted kappa (K). Results: Image quality was excellent in 109 cases and slightly reduced in 13. Twenty-two out of 30 ligaments in the control group were classified as normal (73%) compared with only 32 out of 92 in the injured group (36%). Two or all 3 observers agreed in their grading in 101 out of 122 ligaments (83%). Intraobserver agreement (weighted K) was fair to good (0.33-0.73). Pair-wise interobserver agreement was fair (0.24-0.39). Reasons for divergent grading were insufficient knowledge of normal variations, low signal intensity in the peridental soft tissue obscuring the ligament and interpretation flaw. Conclusion: Whiplash trauma can damage the transverse ligament. By use of high-resolution proton-weighted MR images such lesions can be detected and classified. The reliability of this classification still needs improvement

  16. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

    Science.gov (United States)

    Balint, Richard; Lowe, Tristan; Shearer, Tom

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents--iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid--are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented.

  17. Kobi niteliğindeki sağlık kuruluşlarında iç kontrol sistemi ve önemi

    Directory of Open Access Journals (Sweden)

    Güler GÜNEY

    2014-06-01

    Full Text Available Büyük küçük tüm sağlık kuruluşlarının, sürekliliklerini sağlayabilmeleri ve hedeflerine ulaşabilmeleri bakımından en önemli kriter etkili bir iç kontrol sistemine sahip olmalarıdır. Özellikle Türkiye gibi ekonomisi gelişmekte olan, ticari aktörlerinin çok büyük bir kısmı KOBİ statüsünde olan ülkelerde, ekonomik hayatı hareketlendirmek, sermaye piyasalarının gelişmesi ve işlerliğinin kuvvetlenmesinin sağlanmasında da yine en temel kriter etkin ve etkili bir iç kontrol siteminin varlığıdır. Çünkü etkili bir iç kontrol sistemi; hata, hile ve yolsuzlukların önlenmesinde ve işletme içinde uygulanan politika ve prosedürlerin uygulanma düzeyi ve verimliliğinin sağlanmasında da önemli bir etkendir. İster büyük, ister küçük olsun her işletmede etkin olan ya da olmayan bir iç kontrol mevcuttur. Ancak bu kontrollerin işletmede belirlenmiş bulunan belli politika ve prosedürlere göre yapılıp yapılmadığı ya da etkin olup olmadıkları tartışılabilmektedir. Ülkemizdeki sağlık kuruluşlarından, özellikle sermaye piyasalarında işlem gören kuruluşlarda mevzuatlar gereği iç kontrol sistemi kurulmuş olmasma rağmen, bu iç kontrol sisteminin tamamıyla örgütsel amaçlar doğrultusunda etkili ve verimli şekilde çalıştığını söylemek mümkün değildir. Ülkemizdeki KOBİ niteliğindeki sağlık kuruluşlarının hatırı bir kısmında ise iç kontrol sisteminin oldukça yetersiz ve zayıf olarak nitelenebilecek şekilde uygulandığı ifade edilebilir. Bu da diğer tüm KOBÎ'lerde olduğu gibi sağlık alanındaki kuruluşların büyüme, gelişme ve kurumsallaşması üzerine olumsuz etkide bulunmaktadır. Daha da önemlisi de kurumların örgütsel amaçlarını gerçekleştirmesinde zorluklarla karşılaşmasına sebep olmaktadır. Başka bir deyişle, etkin iç kontrol sisteminin işletmelerin ilgililerine fayda sağlaması gereklidir. Böylece i

  18. All-Epiphyseal Anterior Cruciate Ligament Femoral Tunnel Drilling: Avoiding Injury to the Physis, Lateral Collateral Ligament, Anterolateral Ligament, and Popliteus-A 3-Dimensional Computed Tomography Study.

    Science.gov (United States)

    Shea, Kevin G; Cannamela, Peter C; Fabricant, Peter D; Terhune, Elizabeth B; Polousky, John D; Milewski, Matthew D; Anderson, Allen F; Ganley, Theodore J

    2018-01-25

    To investigate the relation of the at-risk structures (distal femoral physis, lateral collateral ligament, anterolateral ligament, popliteus, and articular cartilage) during all-epiphyseal femoral tunnel drilling. A second purpose was 2-fold: (1) to develop recommendations for tunnel placement and orientation that anatomically reconstruct the anterior cruciate ligament (ACL) while minimizing the risk of injury to these at-risk structures, and (2) to allow for maximal tunnel length to increase the amount of graft in the socket to facilitate healing. Three-dimensional models of 6 skeletally immature knees (aged 7-11 years) were reconstructed from computed tomography and used to simulate all-epiphyseal femoral tunnels. Tunnels began within the ACL footprint and were directed laterally or anterolaterally, with the goal of avoiding injury to at-risk structures. The spatial relation between the ideal tunnel and these structures was evaluated. Full-length tunnels and partial length condyle sockets were simulated in the models using the same trajectories. An anterolateral tunnel could be placed to avoid direct injury to lateral structures. The safe zone on the anterolateral aspect of the femur was larger than that of a tunnel with a direct lateral trajectory (median 127 mm 2 vs 83 mm 2 , P = .028). Anterolateral tunnels were longer than direct lateral tunnels (median 30 mm vs 24 mm, P = .041). Safe angles for anterolateral tunnels were 34° to 40° from the posterior condylar axis; direct lateral tunnels were drilled 4° to 9° from the posterior condylar axis. Sockets could be placed without direct injury to structures at risk with either orientation. An all-epiphyseal ACL femoral tunnel can be placed without causing direct injury to at-risk structures. A tunnel angled anterolaterally from the ACL origin is longer and has a larger safe zone compared with the direct lateral tunnel. The largest safe zone for femoral all-epiphyseal ACL drilling was (1) anterior to

  19. Severe Degeneration of the Medial Collateral Ligament in Hallux Valgus: A Histopathologic Study in 12 Consecutive Patients

    Science.gov (United States)

    Prasitdumrong, Ittipol; Rungprai, Chamnanni; Reeboonlarb, Nitit; Poonpracha, Tara; Phisitkul, Phinit

    2013-01-01

    Objective To determine the degree and location of degenerative changes of the medial collateral ligament of the first metatarsophalangeal joint, using the lateral collateral ligament as a control, in patients undergoing hallux valgus correction. Materials and Methods A strip of medial and lateral collateral ligaments were biopsied from 12 consecutive patients (age 45 ± 4.8 years) with symptomatic hallux valgus. A blinded analysis of histopathology was performed by an experienced pathologist. Results The medial collateral ligament was significantly more degenerated compared to the lateral collateral ligament (x2 = 23.41, DF = 2, p hallux valgus correction. The Authors received no financial support for this study. PMID:24027461

  20. Papilomatosis laríngea juvenil y su relación con la infección genital por virus de papiloma humano durante el embarazo

    OpenAIRE

    Castillo, Haydee Karina; Caro, Vanesa de los Ángeles; González Blanco, Mireya; Acosta, Ligia; Correnti, María; Suárez, Jony

    2015-01-01

    Objetivo: Establecer la relación entre el diagnóstico de papilomatosis laríngea juvenil y la infección genital por virus de papiloma humano durante el embarazo. Métodos: Se incluyeron 18 madres de hijos con diagnóstico de papilomatosis laríngea juvenil. Se revisaron las historias de los niños, se realizó anamnesis a las madres buscando antecedentes de infección por virus de papiloma humano durante el embarazo, se practicó evaluación ginecológica actual, citología, vulvoscopia, vaginoscopia, c...

  1. Androgen action during male sex differentiation includes suppression of cranial suspensory ligament development

    NARCIS (Netherlands)

    J.M.A. Emmen (Judith); A. McLuskey; J.A. Grootegoed (Anton); A.O. Brinkmann (Albert)

    1998-01-01

    textabstractThe cranial suspensory ligament is located on the border of the cranial (mesonephric) mesentery in adult female mammals, which runs between the cranial pole of the internal genitalia and the dorsal abdominal wall. Absence of the cranial suspensory ligament

  2. * Fabrication and Characterization of Biphasic Silk Fibroin Scaffolds for Tendon/Ligament-to-Bone Tissue Engineering.

    Science.gov (United States)

    Font Tellado, Sònia; Bonani, Walter; Balmayor, Elizabeth R; Foehr, Peter; Motta, Antonella; Migliaresi, Claudio; van Griensven, Martijn

    2017-08-01

    Tissue engineering is an attractive strategy for tendon/ligament-to-bone interface repair. The structure and extracellular matrix composition of the interface are complex and allow for a gradual mechanical stress transfer between tendons/ligaments and bone. Thus, scaffolds mimicking the structural features of the native interface may be able to better support functional tissue regeneration. In this study, we fabricated biphasic silk fibroin scaffolds designed to mimic the gradient in collagen molecule alignment present at the interface. The scaffolds had two different pore alignments: anisotropic at the tendon/ligament side and isotropic at the bone side. Total porosity ranged from 50% to 80% and the majority of pores (80-90%) were ligament, enthesis, and cartilage markers significantly changed depending on pore alignment in each region of the scaffolds. In conclusion, the biphasic scaffolds fabricated in this study show promising features for tendon/ligament-to-bone tissue engineering.

  3. MRI of injuries of the lateral ankle ligaments; MRT bei Verletzungen der lateralen und angrenzenden Baender des Sprunggelenks

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria). Inst. fuer Radiologie und Interventionelle Radiologie

    2011-09-15

    The most frequent sport injury of the ankle is located in the lateral ankle ligaments. The diagnosis of lateral collateral ankle ligament trauma is based on patient history, clinical examination, and stress radiography, allowing a fair diagnosis for the daily routine. For the direct visualization and precise diagnosis of the lateral ankle ligaments MRI provides the best answer. MRI is used with controlled positioning of the foot, correct angulation of sequenzes, and distinct analysis of MR findings. Sinus tarsi ligaments and ligaments of the distal syndesmosis should be included to the report. In selected patients MRI allows the best evaluation of the extent of the lateral ankle ligaments. MRI is the method of choice for combined osteochondral injuries and soft tissue lesions too. (orig.)

  4. Absence of sensory function in the reconstructed anterior cruciate ligament

    DEFF Research Database (Denmark)

    Krogsgaard, Michael R; Fischer-Rasmussen, Torsten; Dyhre-Poulsen, Poul

    2011-01-01

    -constructions were stimulated. The sensory threshold was 3.4 times higher in the ACL than in the PCL. Stimulus amplitudes were increased to 1.5-2.0 times the sensory threshold, and a typical inhibitory reflex could be elicited in 9 patients. The latency was the same as for the reflex from the PCL. The stimulus......Cruciate ligaments provide sensory information that cause excitatory as well as inhibitory effects to the activity of the muscles around the knee. The aim of the study was to determine whether these muscular reflexes are reestablished after anterior cruciate ligament (ACL) re-construction. Wire...... electrodes were inserted during arthroscopy into the normal posterior cruciate ligament (PCL) and the reconstructed ACL in 11 patients who had a successful ACL re-construction 8 months to 12 years earlier. After the anesthesia had subsided, the PCL was stimulated electrically through the electrodes...

  5. The predisposing factors for the heterotopic ossification after cervical artificial disc replacement.

    Science.gov (United States)

    Yi, Seong; Shin, Dong Ah; Kim, Keung Nyun; Choi, Gwihyun; Shin, Hyun Chul; Kim, Keun Su; Yoon, Do Heum

    2013-09-01

    Heterotopic ossification (HO) is defined as a formation of bone outside the skeletal system. The reported HO occurrence rate in cervical artificial disc replacement (ADR) is unexpectedly high and is known to vary. However, the predisposing factors for HO in cervical ADR have not yet been elucidated. Investigation of the predisposing factors of HO in cervical arthroplasty and the relationship between degeneration of the cervical spine and HO occurrence. Retrospective study to discover predisposing factors of HO in cervical arthroplasty. A total of 170 patients who underwent cervical ADR were enrolled including full follow-up clinical and radiologic data. Radiologic outcomes were assessed by identification of HOs according to McAfee's classifications. This study enrolled a total of 170 patients who underwent cervical ADR. Pre-existing degenerative change included anterior or posterior osteophytes, ossification of the anterior longitudinal ligament, posterior longitudinal ligament, or ligamentum nuchae. The relationships between basic patient data, pre-existing degenerative change, and HO were investigated using linear logistic regression analysis. Among all 170 patients, HO was found in 69 patients (40.6%). Among the postulated predisposing factors, only male gender and artificial disc device type were shown to be statistically significant. Unexpectedly, preoperative degenerative changes in the cervical spine exerted no significant influence on the occurrence of HOs. The odds ratio of male gender compared with female gender was 2.117. With regard to device type, the odds ratios of Mobi-C (LDR medical, Troyes, France) and ProDisc-C (Synthes, Inc., West Chester, PA, USA) were 5.262 and 7.449, respectively, compared with the Bryan disc. Definite differences in occurrence rate according to the gender of patients and the prosthesis type were identified in this study. Moreover, factors indefinably expected to influence HO in the past were not shown to be risk factors

  6. ICARUS+NESSiE: A proposal for short baseline neutrino anomalies with innovative LAr imaging detectors coupled with large muon spectrometers

    Science.gov (United States)

    Gibin, D.

    2013-04-01

    The proposal for an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam is presented. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin2(2θ) and a larger mass difference Δmnew2. The superior quality of the LAr imaging TPC, in particular its unique electron-π0 discrimination allows full rejection of backgrounds and offers a lossless νe detection capability. The determination of the muon charge with the spectrometers allows the full separation of νμ from anti-νμ and therefore controlling systematics from muon mis-identification largely at high momenta.

  7. Osmanlı Dönemi Başlıklı Ortakent Mezar Taşları Ottoman Period Headed Gravestones of Ortakent

    Directory of Open Access Journals (Sweden)

    H.Kamil BİÇİCİ

    2012-12-01

    Full Text Available This concerns, “Ortakent Gravestones.”. Among the cemetery of Ortakent, The dates of the gravestones are between 18.th-20.th centuries and 20 samples of 30 are from 18.th. century, 9 are from 19.th., 1 is from 20.th. century. Gravestones were of marble. The lenghts of the stones are between 140 cm.-45 cm., their widths are between 36 cm.-14 cm., their thicknesses are between 14 cm.-3.5 cm. Most of the samples are in rectangular and shapes and some are rectangular-prizmal. 3 of them have Foot gravestones. 30 head gravestones have large wadded turban (kavuk, turban (sarık, fez (fes and kerchief. All of the gravestones have inscriptions. 5 of them are without inscriptions. Inscriptions on 3 samples were laid diagonal, and 27 of them were laid in a linear system, 30 of head ve foot gravesones are in good condition. 3 samples are broken. 19 of 30 gravestones are men’s and 11 are of women’s. While scarping was used for making gravestones are scarping, and painting were used as the maindecoration tecnique is seen on foot stone with the painting technique,inscriptions of stones were coloured. Most of the inscriptions anddecorations are relieved. Decoration subjects seen on gravestones arephytomorphic, geometric, objective and calligraphic. “Osmanlı Dönemi Başlıklı Ortakent Mezar Taşları” konulu bu incelemede Ortakent Mezarlığında bulunan 30 mezar taşı araştırılarak, çalışmamızda yer almıştır. Mezar taşlarında tarihi bilinen bütün örnekler XVII. yy. ikinci çeyreği ile XX. yy. ilk çeyreği arasındadır. 30 örnekten 20 tanesi XVIII. yy., 9 tanesi XIX. yy., 1 tanesi XX. yy.dır. Mezar taşlarının hepsi mermer malzemeden yapılmıştır. Mezar taşlarının büyükten küçüğe doğru boyları 140 cm. ile 45 cm., genişlikleri 36 cm. ile 14 cm., kalınlıkları ise 14 ile 3.5 cm. arasında değişmektedir. Ortakent’te bulunan mezar taşları şahideli tiptedir. Örneklerin çoğu dikdörtgen gövdelidir. 3

  8. Three-dimensional CT diagnosis of myositis ossificans of the sacrospinous ligament

    International Nuclear Information System (INIS)

    Agrons, G.A.; Markowitz, R.I.; Bronson, W.E.

    1993-01-01

    We present the case of a 4-year-old female with a complex fracture of the left hemipelvis who, on follow-up CT imaging, developed new ossific densities within the peripelvic soft tissues of the contralateral side. Three-dimensional surface reformations of the pelvis demonstrated myositis ossificans along the course of the right sacrospinous ligament, thus elucidating unsuspected ligamentous injury and implying prior instability. (orig.)

  9. Three-dimensional CT diagnosis of myositis ossificans of the sacrospinous ligament

    Energy Technology Data Exchange (ETDEWEB)

    Agrons, G.A. (Children' s Hospital of Philadelphia, PA (United States)); Markowitz, R.I. (Children' s Hospital of Philadelphia, PA (United States)); Bronson, W.E. (Children' s Hospital of Philadelphia, PA (United States))

    1993-04-01

    We present the case of a 4-year-old female with a complex fracture of the left hemipelvis who, on follow-up CT imaging, developed new ossific densities within the peripelvic soft tissues of the contralateral side. Three-dimensional surface reformations of the pelvis demonstrated myositis ossificans along the course of the right sacrospinous ligament, thus elucidating unsuspected ligamentous injury and implying prior instability. (orig.)

  10. Farklı Miktarlarda Üzüm Çekirdeği Tozu İlave Edilmiş Kaplama Harçlarının Reolojik Özellikleri

    Directory of Open Access Journals (Sweden)

    Özge Süfer

    2015-02-01

    Full Text Available Bu çalışmada, üzüm çekirdeği tozu ilavesi yapılmış kaplama harçlarının reolojik özellikleri incelenmiştir. Kaplama harçları; su, buğday unu, mısır unu, tuz, kabartma tozu ve hidroksipropilmetilselülozdan (HPMC oluşan karışıma farklı oranlarda üzüm çekirdeği tozu ilavesi yapılarak üretilmiştir. Örneklerin görünür viskoziteleri sabit sıcaklıkta (15 °C eşmerkezli silindirik tip viskozimetre ile belirlenmiştir. Kaplama harçlarının kıvam katsayıları ve akış davranış indeksleri Üssel Model ile hesaplanmıştır. Bütün örnekler Newton tipi olmayan pseudoplastik tipi akış davranışı sergilemiş ve görünür viskozite değerleri artan kayma hızı ile azalmıştır. Örneklerin görünür viskozite değerleri, artan üzüm çekirdeği konsantrasyonu ile birlikte azalmıştır. Kaplama harçlarının akış davranış indeksi ve kıvam katsayısı değerleri sırasıyla 0.516-0.596 ve 8.994-14.722 Pa.s aralığında bulunmuştur.

  11. Ligament rupture and unstable burst behaviors of axial flaws in steam generator U-bends

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Chi Bum, E-mail: bahn@pusan.ac.kr [Pusan National University, 2 Busandaehak-ro 63 beon-gil, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Oh, Young-Jin [KEPCO Engineering & Construction Co. Inc., Seongnam 463-870 (Korea, Republic of); Majumdar, Saurin [Argonne National Laboratory, Lemont, IL 60439 (United States)

    2015-11-15

    Highlights: • Ligament rupture and unstable burst pressure tests were conducted with U-bends. • In general, U-bends showed higher ligament rupture and burst pressures than straight tubes. • U-bend test data was bounded by 90% lower limit of the probabilistic models for straight tubes. • Prediction models for straight tubes could be conservatively applied to U-bends. - Abstract: Incidents of U-bend cracking in steam generator (SG) tubes have been reported, some of which have led to tube rupture. Experimental and analytical modeling efforts to determine the failure criteria of flawed SG U-bends are limited. To evaluate structural integrity of flawed U-bends, ligament rupture and unstable burst pressure tests were conducted on 57 and 152 mm bend radius U-bends with axial electrical discharge machining notches. In general, the ligament rupture and burst pressures of the U-bends were higher than those of straight tubes with similar notches. To quantitatively address the test data scatter issue, probabilistic models were introduced. All ligament rupture and burst pressures of U-bends were bounded by 90% lower limits of the probabilistic models for straight tubes. It was concluded that the prediction models for straight tubes could be applied to U-bends to conservatively evaluate the ligament rupture and burst pressures of U-bends with axial flaws.

  12. Ligament rupture and unstable burst behaviors of axial flaws in steam generator U-bends

    International Nuclear Information System (INIS)

    Bahn, Chi Bum; Oh, Young-Jin; Majumdar, Saurin

    2015-01-01

    Highlights: • Ligament rupture and unstable burst pressure tests were conducted with U-bends. • In general, U-bends showed higher ligament rupture and burst pressures than straight tubes. • U-bend test data was bounded by 90% lower limit of the probabilistic models for straight tubes. • Prediction models for straight tubes could be conservatively applied to U-bends. - Abstract: Incidents of U-bend cracking in steam generator (SG) tubes have been reported, some of which have led to tube rupture. Experimental and analytical modeling efforts to determine the failure criteria of flawed SG U-bends are limited. To evaluate structural integrity of flawed U-bends, ligament rupture and unstable burst pressure tests were conducted on 57 and 152 mm bend radius U-bends with axial electrical discharge machining notches. In general, the ligament rupture and burst pressures of the U-bends were higher than those of straight tubes with similar notches. To quantitatively address the test data scatter issue, probabilistic models were introduced. All ligament rupture and burst pressures of U-bends were bounded by 90% lower limits of the probabilistic models for straight tubes. It was concluded that the prediction models for straight tubes could be applied to U-bends to conservatively evaluate the ligament rupture and burst pressures of U-bends with axial flaws.

  13. Research and development for a free-running readout system for the ATLAS LAr Calorimeters at the high luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Hils, Maximilian, E-mail: maximilian.hils@tu-dresden.de

    2016-07-11

    The ATLAS Liquid Argon (LAr) Calorimeters were designed and built to measure electromagnetic and hadronic energy in proton–proton collisions produced at the Large Hadron Collider (LHC) at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 10{sup 34} cm{sup −2} s{sup −1}. The High Luminosity LHC (HL-LHC) programme is now developed for up to 5–7 times the design luminosity, with the goal of accumulating an integrated luminosity of 3000 fb{sup −1}. In the HL-LHC phase, the increased radiation levels and an improved ATLAS trigger system require a replacement of the Front-end (FE) and Back-end (BE) electronics of the LAr Calorimeters. Results from research and development of individual components and their radiation qualification as well as the overall system design will be presented.

  14. Fibre recruitment and shape changes of knee ligaments during motion: as revealed by a computer graphics-based model.

    Science.gov (United States)

    Lu, T W; O'Connor, J J

    1996-01-01

    A computer graphics-based model of the knee ligaments in the sagittal plane was developed for the simulation and visualization of the shape changes and fibre recruitment process of the ligaments during motion under unloaded and loaded conditions. The cruciate and collateral ligaments were modelled as ordered arrays of fibres which link attachment areas on the tibia and femur. Fibres slacken and tighten as the ligament attachment areas on the bones rotate and translate relative to each other. A four-bar linkage, composed of the femur, tibia and selected isometric fibres of the two cruciates, was used to determine the motion of the femur relative to the tibia during passive (unloaded) movement. Fibres were assumed to slacken in a Euler buckling mode when the distances between their attachments are less than chosen reference lengths. The ligament shape changes and buckling patterns are demonstrated with computer graphics. When the tibia is translated anteriorly or posteriorly relative to the femur by muscle forces and external loads, some ligament fibres tighten and are recruited progressively to transmit increasing shear forces. The shape changes and fibre recruitment patterns predicted by the model compare well qualitatively with experimental results reported in the literature. The computer graphics approach provides insight into the micro behaviour of the knee ligaments. It may help to explain ligament injury mechanisms and provide useful information to guide the design of ligament replacements.

  15. Proteomic differences between native and tissue-engineered tendon and ligament.

    Science.gov (United States)

    Kharaz, Yalda A; Tew, Simon R; Peffers, Mandy; Canty-Laird, Elizabeth G; Comerford, Eithne

    2016-05-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age-related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin-based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular-associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. The exercise-induced biochemical milieu enhances collagen content and tensile strength of engineered ligaments.

    Science.gov (United States)

    West, Daniel W D; Lee-Barthel, Ann; McIntyre, Todd; Shamim, Baubak; Lee, Cassandra A; Baar, Keith

    2015-10-15

    Exercise stimulates a dramatic change in the concentration of circulating hormones, such as growth hormone (GH), but the biological functions of this response are unclear. Pharmacological GH administration stimulates collagen synthesis; however, whether the post-exercise systemic milieu has a similar action is unknown. We aimed to determine whether the collagen content and tensile strength of tissue-engineered ligaments is enhanced by serum obtained post-exercise. Primary cells from a human anterior cruciate ligament (ACL) were used to engineer ligament constructs in vitro. Blood obtained from 12 healthy young men 15 min after resistance exercise contained GH concentrations that were ∼7-fold greater than resting serum (P Ligament constructs were treated for 7 days with medium supplemented with serum obtained at rest (RestTx) or 15 min post-exercise (ExTx), before tensile testing and collagen content analysis. Compared with RestTx, ExTx enhanced collagen content (+19%; 181 ± 33 vs. 215 ± 40 μg per construct P = 0.001) and ligament mechanical properties - maximal tensile load (+17%, P = 0.03 vs. RestTx) and ultimate tensile strength (+10%, P = 0.15 vs. RestTx). In a separate set of engineered ligaments, recombinant IGF-1, but not GH, enhanced collagen content and mechanics. Bioassays in 2D culture revealed that acute treatment with post-exercise serum activated mTORC1 and ERK1/2. In conclusion, the post-exercise biochemical milieu, but not recombinant GH, enhances collagen content and tensile strength of engineered ligaments, in association with mTORC1 and ERK1/2 activation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  17. The suitability of human adipose-derived stem cells for the engineering of ligament tissue.

    Science.gov (United States)

    Eagan, Michael J; Zuk, Patricia A; Zhao, Ke-Wei; Bluth, Benjamin E; Brinkmann, Elyse J; Wu, Benjamin M; McAllister, David R

    2012-10-01

    Rupture of the anterior cruciate ligament (ACL) is the one of the most common sports-related injuries. With its poor healing capacity, surgical reconstruction using either autografts or allografts is currently required to restore function. However, serious complications are associated with graft reconstructions and the number of such reconstructions has steadily risen over the years, necessitating the search for an alternative approach to ACL repair. Such an approach may likely be tissue engineering. Recent engineering approaches using ligament-derived fibroblasts have been promising, but the slow growth rate of such fibroblasts in vitro may limit their practical application. More promising results are being achieved using bone marrow mesenchymal stem cells (MSCs). The adipose-derived stem cell (ASC) is often proposed as an alternative choice to the MSC and, as such, may be a suitable stem cell for ligament engineering. However, the use of ASCs in ligament engineering still remains relatively unexplored. Therefore, in this study, the potential use of human ASCs in ligament tissue engineering was initially explored by examining their ability to express several ligament markers under growth factor treatment. ASC populations treated for up to 4 weeks with TGFβ1 or IGF1 did not show any significant and consistent upregulation in the expression of collagen types 1 and 3, tenascin C and scleraxis. While treatment with EGF or bFGF resulted in increased tenascin C expression, increased expression of collagens 1 and 3 were never observed. Therefore, simple in vitro treatment of human ASC populations with growth factors may not stimulate their ligament differentiative potential. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Do cells contribute to tendon and ligament biomechanics?

    Directory of Open Access Journals (Sweden)

    Niels Hammer

    Full Text Available Acellular scaffolds are increasingly used for the surgical repair of tendon injury and ligament tears. Despite this increased use, very little data exist directly comparing acellular scaffolds and their native counterparts. Such a comparison would help establish the effectiveness of the acellularization procedure of human tissues. Furthermore, such a comparison would help estimate the influence of cells in ligament and tendon stability and give insight into the effects of acellularization on collagen.Eighteen human iliotibial tract samples were obtained from nine body donors. Nine samples were acellularized with sodium dodecyl sulphate (SDS, while nine counterparts from the same donors remained in the native condition. The ends of all samples were plastinated to minimize material slippage. Their water content was adjusted to 69%, using the osmotic stress technique to exclude water content-related alterations of the mechanical properties. Uniaxial tensile testing was performed to obtain the elastic modulus, ultimate stress and maximum strain. The effectiveness of the acellularization procedure was histologically verified by means of a DNA assay.The histology samples showed a complete removal of the cells, an extensive, yet incomplete removal of the DNA content and alterations to the extracellular collagen. Tensile properties of the tract samples such as elastic modulus and ultimate stress were unaffected by acellularization with the exception of maximum strain.The data indicate that cells influence the mechanical properties of ligaments and tendons in vitro to a negligible extent. Moreover, acellularization with SDS alters material properties to a minor extent, indicating that this method provides a biomechanical match in ligament and tendon reconstruction. However, the given protocol insufficiently removes DNA. This may increase the potential for transplant rejection when acellular tract scaffolds are used in soft tissue repair. Further research

  19. Mechanical stability of the subtalar joint after lateral ligament sectioning and ankle brace application: a biomechanical experimental study.

    Science.gov (United States)

    Kamiya, Tomoaki; Kura, Hideji; Suzuki, Daisuke; Uchiyama, Eiichi; Fujimiya, Mineko; Yamashita, Toshihiko

    2009-12-01

    The roles of each ligament supporting the subtalar joint have not been clarified despite several biomechanical studies. The effects of ankle braces on subtalar instability have not been shown. The ankle brace has a partial effect on restricting excessive motion of the subtalar joint. Controlled laboratory study. Ten normal fresh-frozen cadaveric specimens were used. The angular motions of the talus were measured via a magnetic tracking system. The specimens were tested while inversion and eversion forces, as well as internal and external rotation torques, were applied. The calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament were sectioned sequentially, and the roles of each ligament, as well as the stabilizing effects of the ankle brace, were examined. Complete sectioning of the ligaments increased the angle between the talus and calcaneus in the frontal plane to 51.7 degrees + or - 11.8 degrees compared with 35.7 degrees + or - 6.0 degrees in the intact state when inversion force was applied. There was a statistically significant difference in the angles between complete sectioning of the ligaments and after application of the brace (34.1 degrees + or - 7.3 degrees ) when inversion force was applied. On the other hand, significant differences in subtalar rotation were not found between complete sectioning of the ligaments and application of the brace when internal and external rotational torques were applied. The ankle brace limited inversion of the subtalar joint, but it did not restrict motion after application of internal or external rotational torques. In cases of severe ankle sprains involving the calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament injuries, application of an ankle brace might be less effective in limiting internal-external rotational instabilities than in cases of inversion instabilities in the subtalar joint. An improvement in the design of the brace is needed to restore

  20. Anatomic feature of deltoid ligament attachment in posteromedial osteochondral lesion of talar dome.

    Science.gov (United States)

    Nakasa, Tomoyuki; Sawa, Mikiya; Ikuta, Yasunari; Yoshikawa, Masahiro; Tsuyuguchi, Yusuke; Adachi, Nobuo

    2018-03-01

    Osteochondral lesions of the talus (OLT) are recognized as being commonly associated with trauma. However, the etiology of OLT remains unclear. In the case of a posteromedial lesion of OLT (medial OLT), the deep layer of the deltoid ligament is located close to the medial OLT, and this relationship between a medial lesion and deltoid ligament could be a risk factor for medial OLT. The purpose of this study is to investigate the unique anatomic feature of the deep deltoid attachment to the talus in patients with medial OLT compared with patients with non-medial OLT. Forty ankles with medial OLT and 40 ankles without medial OLT were retrospectively reviewed in this study. On the coronal images of MRI, the attachment of deltoid ligament was measured. The continuity of the osteochondral fragment and its bed was evaluated on MRI and arthroscopic findings. Coronal MRI images showed that the attachment of the deep deltoid ligament to the medial OLT was broader and located more proximally than in non-medial OLT. The continuity of fibers from the insertion site of deltoid ligament to the talus to the osteochondral fragment was observed (76.7%). In the arthroscopic findings, the osteochondral fragment was obviously connected to the talus at the medial site in 85.2% of feet. The location of the deep deltoid ligament attachment to the medial OLT was more proximal and there was the possibility of these anatomic feature might contribute to the pathogenesis of medial OLT. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  1. The "moving valgus stress test" for medial collateral ligament tears of the elbow.

    Science.gov (United States)

    O'Driscoll, Shawn W M; Lawton, Richard L; Smith, Adam M

    2005-02-01

    The diagnosis of a painful partial tear of the medial collateral ligament in overhead-throwing athletes is challenging, even for experienced elbow surgeons and despite the use of sophisticated imaging techniques. The "moving valgus stress test" is an accurate physical examination technique for diagnosis of medial collateral ligament attenuation in the elbow. Cohort study (diagnosis); Level of evidence, 2. Twenty-one patients underwent surgical intervention for medial elbow pain due to medial collateral ligament insufficiency or other abnormality of chronic valgus overload, and they were assessed preoperatively with an examination called the moving valgus stress test. To perform the moving valgus stress test, the examiner applies and maintains a constant moderate valgus torque to the fully flexed elbow and then quickly extends the elbow. The test is positive if the medial elbow pain is reproduced at the medial collateral ligament and is at maximum between 120 degrees and 70 degrees. The moving valgus stress test was highly sensitive (100%, 17 of 17 patients) and specific (75%, 3 of 4 patients) when compared to assessment of the medial collateral ligament by surgical exploration or arthroscopic valgus stress testing. The mean shear range (ie, the arc within which pain was produced with the moving valgus stress test) was 120 degrees to 70 degrees. The mean angle at which pain was at a maximum was 90 degrees of elbow flexion. The moving valgus stress test is an accurate physical examination technique that, when performed and interpreted correctly, is highly sensitive for medial elbow pain arising from the medial collateral ligament.

  2. Three-dimensional magnetic resonance imaging for ruptures of the lateral ligaments of the ankle

    International Nuclear Information System (INIS)

    Verhaven, E.; Handelberg, F.; Opdecam, P.; Shahabpour, M.; Osteaux, M.; Vaes, P.

    1990-01-01

    The accuracy has been determined of three-dimensional MRI in visualizing the anterior talofibular and the calcaneofibular ligament in young athletes with an acute severe sprain of the lateral ligaments of the ankle by comparing these findings with those found at operation and evaluating three-dimensional fast imaging with steady state precession (3D FISP) as a diagnostic aid to operative planning for tears of both the anterior talofibular and the calcaneofibular ligament in younger competitive athletes. (author). 20 refs.; 2 figs

  3. Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images

    International Nuclear Information System (INIS)

    Duc, Sylvain R.; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments. (orig.)

  4. Dynamic Failure Properties of the Porcine Medial Collateral Ligament-Bone Complex for Predicting Injury in Automotive Collisions

    Science.gov (United States)

    Peck, Louis; Billiar, Kristen; Ray, Malcolm

    2010-01-01

    The goal of this study was to model the dynamic failure properties of ligaments and their attachment sites to facilitate the development of more realistic dynamic finite element models of the human lower extremities for use in automotive collision simulations. Porcine medial collateral ligaments were chosen as a test model due to their similarities in size and geometry with human ligaments. Each porcine medial collateral ligament-bone complex (n = 12) was held in a custom test fixture placed in a drop tower to apply an axial impulsive impact load, applying strain rates ranging from 0.005 s-1 to 145 s-1. The data from the impact tests were analyzed using nonlinear regression to construct model equations for predicting the failure load of ligament-bone complexes subjected to specific strain rates as calculated from finite element knee, thigh, and hip impact simulations. The majority of the ligaments tested failed by tibial avulsion (75%) while the remaining ligaments failed via mid-substance tearing. The failure load ranged from 384 N to 1184 N and was found to increase with the applied strain rate and the product of ligament length and cross-sectional area. The findings of this study indicate the force required to rupture the porcine MCL increases with the applied bone-to-bone strain rate in the range expected from high speed frontal automotive collisions. PMID:20461229

  5. Atypically thick and high location of the Wrisberg ligament in patients with a complete lateral discoid meniscus

    International Nuclear Information System (INIS)

    Kim, Eun Young; Choi, Sang-Hee; Kwon, Jong Won; Ahn, Jin Hwan

    2008-01-01

    The purpose of this study was to document the relationship between a discoid lateral meniscus and a thickened Wrisberg ligament with a higher location on the medial femoral condyle. Between July 2002 and February 2006, 100 consecutive patients who had a complete lateral discoid meniscus and another 100 patients without a discoid lateral meniscus (control group) were included. Two radiologists retrospectively reviewed all of the magnetic resonance images, paying particular attention to the presence and thickness of the Wrisberg ligament and the location of the attachment of the Wrisberg ligament to the medial femoral condyle (types I, II, or III). We assumed that type I Wrisberg ligaments had a higher location. All 141 patients had a Wrisberg ligament (71%). There were 73 patients (73%) in the discoid group and 68 patients (68%) in the non-discoid group. The mean thickness of the Wrisberg ligament in the patients in the discoid and non-discoid groups was 2.1 mm (range, 0.4-4.7 mm; median, 2.1 mm) and 1.6 mm (range, 0.4-4.5 mm; median, 1.3 mm), respectively. The Wrisberg ligaments of the discoid group were thicker than the non-discoid group (p=0.0002). The Wrisberg ligament was attached to the upper part of the medial femoral condyle in the discoid group more often than in the non-discoid group (p<0.0001). (orig.)

  6. Can MRI distinguish between acute partial and complete anterior cruciate ligament tear?

    International Nuclear Information System (INIS)

    Yamato, Minoru; Yamagishi, Tsuneo.

    1996-01-01

    A study to elucidate the title problem was done. Subjects were 8 patients with partial anterior cruciate ligament (ACL) tear diagnosed by both MRI and arthroscopy within 6 weeks after trauma, 14 patients with complete ACL tear diagnosed similarly and 10 control patients with arthroscopically intact ACL. Proton density-and T2-weighted MRI imaging of the sagittal section of the knee was performed with 1.5 T magnets (Siemens Magnetom H15, Shimadzu SMT150GUX) by using a dedicated knee coil, with slice thickness of 4-5 mm and 14-16 cm field of view. The examination was done on the primary (discontinuity of low signal band, abnormal axis of the ligament and focal or diffuse increased signal intensity) and secondary (bone bruise, anterior translocation of the tibia and PCL curvature value) signs of ACL tear. In proton density-weighted sagittal images, it was found easy to distinguish acute partial ACL tear from normal ligament but not from complete ACL tear. In T2-weighted images, partial ACL tear was suggested to keep continuity of the ligament. (H.O.)

  7. Magnetic resonance evaluation of the labral capsular ligamentous complex: a pictorial review

    International Nuclear Information System (INIS)

    Connell, D.A.; Potter, H.G.

    1999-01-01

    Magnetic resonance imaging of the shoulder is a common imaging test, and in the course of routine evaluation it can provide accurate information regarding the labral capsular ligamentous complex (LCLC). Common patterns of labral injury include fraying, flap tears and labral distraction, which can be readily identified on both coronal and axial planes by paying attention to signal and morphological characteristics. Capsular and ligamentous pathology may be subtle, but is recognizable using a high-resolution technique that has differential contrast between native intra-articular fluid and the adjacent labrum and capsular restraints. Common patterns of capsular injury include a thickened, hyperintense capsule, sometimes with disruption and retraction. The inferior glenohumeral ligament is the primary stabilizer of the shoulder joint, and although failure of this structure is uncommon, the injury is easily identified. Shoulder instability is a common presentation, the diagnosis of which is dependent upon recognising various injury patterns including Bankart lesions, reverse Bankart lesions, anterior labroligamentous periosteal sleeve avulsion (ALPSA) and failure of the inferior glenohumeral ligament. Copyright (1999) Blackwell Science Pty Ltd

  8. Lesiones laríngeas postintubación endotraqueal. Factores de riesgo asociados

    OpenAIRE

    Bosque Cebolla, M. Dolores

    2015-01-01

    Introducción: La intubación endotraqueal para el mantenimiento de una correcta función respiratoria o incluso como mantenimiento de una vía aérea superior permeable es uno de los procedimientos más habituales en los pacientes críticos. Se trata de un procedimiento que no está exento de complicaciones, muchas de ellas relacionadas con la presencia del tubo endotraqueal a nivel laríngeo y que abarcan desde síntomas y lesiones leves y reversibles hasta lesiones más graves como las estenosis lari...

  9. The spatiotemporal development of innervation in spinal ligaments of chickens.

    OpenAIRE

    Jiang, H; Moreau, M; Greidanus, N; Bilo, J; Russell, G; Raso, J; Bagnall, K

    1996-01-01

    The development of the innervation of both central and lateral (intertransverse) spinal ligaments was investigated in chickens between the time of hatching and 13 wk of age. A total of 36 White Leghorn chickens in 4 groups of 9 at ages 0, 2, 7, and 13 wk were used. The spinal ligaments were dissected, serially sectioned and labelled with a monoclonal antibody against neurofilament protein and observed using either conventional fluorescence or confocal microscopy. Only a few nerve elements wer...

  10. Kinematics of partial and total ruptures of the medial collateral ligament of the elbow

    DEFF Research Database (Denmark)

    Eygendaal, D; Olsen, Bo Sanderhoff; Jensen, Steen Lund

    2000-01-01

    In this study the kinematics of partial and total ruptures of the medial collateral ligament of the elbow are investigated. After selective transection of the medial collateral ligament of 8 osteoligamentous intact elbow preparations was performed, 3-dimensional measurements of angular displacement......, increase in medial joint opening, and translation of the radial head were examined during application of relevant stress. Increase in joint opening was significant only after complete transection of the anterior part of the medial collateral ligament was performed. The joint opening was detected during...... valgus and internal rotatory stress only. After partial transection of the anterior bundle of the medial collateral ligament was performed, there was an elbow laxity to valgus and internal rotatory force, which became significant after transection of 100% of the anterior bundle of the medial collateral...

  11. In vivo recruitment patterns in the anterior oblique and dorsoradial ligaments of the first carpometacarpal joint

    Science.gov (United States)

    Halilaj, Eni; Rainbow, Michael J.; Moore, Douglas C.; Laidlaw, David H.; Weiss, Arnold-Peter C.; Ladd, Amy L.; Crisco, Joseph J.

    2015-01-01

    The anterior oblique ligament (AOL) and the dorsoradial ligament (DRL) are both regarded as mechanical stabilizers of the thumb carpometacarpal (CMC) joint, which in older women is often affected by osteoarthritis. Inferences on the potential relationship of these ligaments to joint pathomechanics are based on clinical experience and studies of cadaveric tissue, but their function has been studied sparsely in vivo. The purpose of this study was to gain insight into the functions of the AOL and DRL using in vivo joint kinematic data. The thumbs of 44 healthy subjects were imaged with a clinical computed tomography scanner in functional-task and thumb range-of-motion positions. The origins and insertion sites of the AOL and the DRL were identified on the 3D bone models and each ligament was modeled as a set of three fibers whose lengths were the minimum distances between insertion sites. Ligament recruitment, which represented ligament length as a percentage of the maximum length across the scanned positions, was computed for each position and related to joint posture. Mean AOL recruitment was lower than 91% across the CMC range of motion, whereas mean DRL recruitment was generally higher than 91% in abduction and flexion. Under the assumption that ligaments do not strain by more than 10% physiologically, our findings of mean ligament recruitments across the CMC range of motion indicate that the AOL is likely slack during most physiological positions, whereas the DRL may be taut and therefore support the joint in positions of CMC joint abduction and flexion. PMID:25964211

  12. Tendo-ligamentous pathologies of the wrist joint: Can ultrasonography replace magnetic resonance imaging?

    Directory of Open Access Journals (Sweden)

    Kunwarpal Singh

    2017-09-01

    Full Text Available Background: Characterization of tendo-ligamentous pathologies of wrist remains problematic, despite advances in imaging. By using clinical history and imaging appearance, one can determine the diagnosis. USG is used as first imaging modality whereas MRI aids in making a specific diagnosis of few of the lesions. Aims: To investigate the etiological spectrum of tendo-ligamentous pathologies of wrist on USG & MRI with statistical correlation. Patients and methods: 80 patients (male/female = 46/34 with complaint of swelling or pain in wrist were included and underwent USG and MRI of both the wrists. Results: The spectrum included ganglion cysts, vascular malformations, tenosynovitis, tendinopathy, ligament tears and fibrosis. The analysis was done using kappa coefficient and spearman's rho correlation coefficient. The strength of agreement between USG and MRI for the diagnosis of ganglion cysts, vascular malformations, tenosynovitis and tendinopathy was found to be very good. Conclusion: USG provides detailed depiction of superficial structures, is less expensive, and allows dynamic examinations of the wrist. It should be the first choice of investigation for majority of the cystic, tendinous, vascular, and fibrotic pathologies of the wrist. However, less promising results were observed for ligamentous pathologies on USG in our study. Keywords: Tendo-ligamentous pathologies, Ganglion cyst, Tenosynovitis, Ultrasonography, MRI

  13. Calcification of the alar ligament of the cervical spine in a patient ...

    African Journals Online (AJOL)

    Calcification of the alar ligament is rare. It usually develops as a result of traumatic injury and is especially prominent in the elderly. CT scanning is the gold standard of the diagnosis. We report a case of a calcification of the transverse and alar ligament in a patient with rheumatoid arthritis. Pan African Medical Journal 2012; ...

  14. Falciform ligament abscess from left sided portal pyaemia following malignant obstructive cholangitis

    Directory of Open Access Journals (Sweden)

    Warren Leigh R

    2012-12-01

    Full Text Available Abstract Abscess formation of the falciform ligament is incredibly rare and perplexing when encountered for the first time. It is reported to occur in the setting of cholecystitis and cholangitis, but the pathophysiology is poorly understood. In this case report, we present a 73-year-old man with falciform ligament abscess following cholangitis from an obstructive ampullary carcinoma. The patient was referred to the Royal Adelaide Hospital from a country hospital, with progressive jaundice, anorexia and nausea. Prior to transfer, he deteriorated with cholangitis, dehydration and renal failure. On arrival, his abdomen was exquisitely tender along the course of the falciform ligament. His blood tests revealed an elevated white cell count of 14.9 x 103/μl, bilirubin of 291μmol/l and creatinine of 347 μmol/l. His CA 19-9 was markedly elevated at 35,000 kU/l. A non-contrast computed tomography (CT demonstrated gross biliary dilatation and a collection tracking along the path of the falciform ligament to the umbilicus. The patient was commenced on intravenous antibiotics and underwent an urgent endoscopic retrograde cholangiopancreatogram (ERCP with sphincterotomy and biliary stent drainage. Cholangiogram revealed a grossly dilated biliary tree, with abrupt transition at the ampulla, which on biopsy confirmed an obstructing ampullary carcinoma. Following ERCP, his jaundice and abdominal tenderness resolved. He was optimized over 4 weeks for an elective pancreaticoduodenectomy. At operation, we found abscess transformation of the falciform ligament. Copious amounts of pus and necrotic material was drained. Part of the round ligament was resected along the undersurface of the liver. Histology showed that there was prominent histiocytic inflammation with granular acellular eosinophilic components. The patient recovered slowly but uneventfully. A contrast CT scan undertaken 2 weeks post-operatively (approximately 7 weeks after the initial CT revealed

  15. Factors Affecting the Longevity and Strength in an In Vitro Model of the Bone–Ligament Interface

    Science.gov (United States)

    Paxton, Jennifer Z.; Donnelly, Kenneth; Keatch, Robert P.; Grover, Liam M.

    2010-01-01

    The interfaces between musculoskeletal tissues with contrasting moduli are morphologically and biochemically adapted to allow the transmission of force with minimal injury. Current methods of tissue engineering ligaments and tendons do not include the interface and this may limit the future clinical success of engineered musculoskeletal tissues. This study aimed to use solid brushite cement anchors to engineer intact ligaments from bone-to-bone, creating a functional musculoskeletal interface in vitro. We show here that modifying anchor shape and cement composition can alter both the longevity and the strength of an in vitro model of the bone–ligament interface: with values reaching 23 days and 21.6 kPa, respectively. These results validate the use of brushite bone cement to engineer the bone–ligament interface in vitro and raise the potential for future use in ligament replacement surgery. PMID:20431953

  16. Bioactive nanofibers for fibroblastic differentiation of mesenchymal precursor cells for ligament/tendon tissue engineering applications.

    Science.gov (United States)

    Sahoo, Sambit; Ang, Lay-Teng; Cho-Hong Goh, James; Toh, Siew-Lok

    2010-02-01

    Mesenchymal stem cells and precursor cells are ideal candidates for tendon and ligament tissue engineering; however, for the stem cell-based approach to succeed, these cells would be required to proliferate and differentiate into tendon/ligament fibroblasts on the tissue engineering scaffold. Among the various fiber-based scaffolds that have been used in tendon/ligament tissue engineering, hybrid fibrous scaffolds comprising both microfibers and nanofibers have been recently shown to be particularly promising. With the nanofibrous coating presenting a biomimetic surface, the scaffolds can also potentially mimic the natural extracellular matrix in function by acting as a depot for sustained release of growth factors. In this study, we demonstrate that basic fibroblast growth factor (bFGF) could be successfully incorporated, randomly dispersed within blend-electrospun nanofibers and released in a bioactive form over 1 week. The released bioactive bFGF activated tyrosine phosphorylation signaling within seeded BMSCs. The bFGF-releasing nanofibrous scaffolds facilitated BMSC proliferation, upregulated gene expression of tendon/ligament-specific ECM proteins, increased production and deposition of collagen and tenascin-C, reduced multipotency of the BMSCs and induced tendon/ligament-like fibroblastic differentiation, indicating their potential in tendon/ligament tissue engineering applications. 2009 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.

  17. Collateral ligament reconstruction of the chronic thumb injury with bio-tenodesis screw fixation

    DEFF Research Database (Denmark)

    Gvozdenovic, Robert; Boeckstyns, Michel

    2014-01-01

    We describe a new technique for the reconstruction of chronic lesions of the collateral ligaments of the metacarpophalangeal ligaments of the thumb, using a Bio-Tenodesis screw for the fixation of a tendon graft in a triangular manner with proximal apex and allowing early mobilization, starting 2...

  18. Change in the collateral and accessory collateral ligament lengths of the proximal interphalangeal joint using cadaveric model three-dimensional laser scanning.

    Science.gov (United States)

    Sandhu, S S; Dreckmann, S; Binhammer, P A

    2016-05-01

    The purpose of this study was to assess the lengths of the index and middle finger proximal interphalangeal joint ligaments and determine the relative changes in the collateral and accessory collateral ligament lengths at 0°, 45° and 90° flexion. We generated three-dimensional scans of 16 finger (eight index and eight middle) proximal interphalangeal joints to assess relative changes in ligament length. Significant changes were found between 45°-90° and 0°-90° for the ulnar collateral ligament of the index finger and both collateral ligaments of the middle finger between 45°-90° and 0°-90°. No significant changes in length were found for the radial collateral ligament of the index finger or the accessory collateral ligaments of the index and middle fingers. Overall, it was found that the collateral ligament length changed significantly, but there was no significant change in the accessory collateral ligaments. Therapeutic IV. © The Author(s) 2015.

  19. Distribution of 3H-fucose in the transseptal ligament of the mouse

    International Nuclear Information System (INIS)

    Johnson, R.B.

    1988-01-01

    The present study demonstrated 3 H-fucose distribution in three regions of the transseptal ligament; the middle, mesial (adjacent to the first molar tooth) and distal (adjacent to the second molar tooth) thirds; og 6-week- and 6-month-old Swiss mice. Incorporation of the isotope was rapid and maximal peaks occurred at 3 hours in most regions of 6-month and at 12 h in most regions of 6-wk animals: highest grain counts were over the middle third of the ligament of 6-wk animals (p<0.001). During incorporation, mean grain counts were significantly different as a function of age (p<0.001), region (p<0.01) and time (p<0.001) and there was a significant interaction between region and time (p<0.005). Grain removal occurred at a slower rate: there were significant differences in mean grain counts as a function of age (p<0.001), region (p<0.001) and time (p<0.001) and a significant interaction between time and region (p<0.001) and between time, region and age (p<0.001). The highest rate of grain removal was in the middle third of the ligament of 6-wk animals. Half-life of labeled glycoproteins was shortest in the ligament of 6-wk animals. The study suggested regional differences in metabolism of fucose-containing glycoproteins of the transseptal ligament: highest turnover rates in the 1) middle third, and 2) young animals. (author)

  20. The Spatial Relationship and Surface Projection of Canine Sciatic Nerve and Sacrotuberous Ligament: A Perineal Hernia Repair Perspective.

    Science.gov (United States)

    Khatri-Chhetri, Nabin; Khatri-Chhetri, Rupak; Chung, Cheng-Shu; Chern, Rey-Shyong; Chien, Chi-Hsien

    2016-01-01

    Sciatic nerve entrapment can occur as post-operative complication of perineal hernia repair when sacrotuberous ligament is incorporated during hernia deficit closure. This results in sciatic sensory loss and paralysis of the hind leg. This study investigated the spatial relationship of sciatic nerve and sacrotuberous ligament and their surface topographic projection of 68 cadavers (29 Beagles and 39 Taiwanese mongrels) with various heights (25-56 cm). By gross dissection, the sacrotuberous ligament and sciatic nerve were exposed and their distance in between was measured along four parts (A, B, C, D) of sacrotuberous ligament. The present study revealed that the C was the section of sacrotuberous ligament where the sciatic nerve and the sacrotuberous ligament are closest to each other. Furthermore, a positive correlation was observed between C and height of the dogs. From the present study, we found that the C in smaller dogs has the shortest distance between the sciatic nerve and the sacrotuberous ligament, and thus the most vulnerable to sciatic nerve entrapment, and needs to be avoided or approached cautiously during perineal hernia repair.