  1. The design and implementation of on-line monitoring system for UHV compact shunt capacitors

    Science.gov (United States)

    Tao, Weiliang; Ni, Xuefeng; Lin, Hao; Jiang, Shengbao

    2017-08-01

    Because of the large capacity and compact structure of the UHV compact shunt capacitor, it is difficult to take effective measures to detect and prevent the faults. If the fault capacitor fails to take timely maintenance, it will pose a threat to the safe operation of the system and the life safety of the maintenance personnel. The development of UHV compact shunt capacitor on-line monitoring system can detect and record the on-line operation information of UHV compact shunt capacitors, analyze and evaluate the early fault warning signs, find out the fault capacitor or the capacitor with fault symptom, to ensure safe and reliable operation of the system.

  2. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    Science.gov (United States)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be

  3. Incorporation of distributed generation and shunt capacitor in radial distribution system for techno-economic benefits

    Directory of Open Access Journals (Sweden)

    Mukul Dixit

    2017-04-01

    The various costs such as purchase active power from grid, DG installation, capacitor installation, DG Operation and Maintenance (O&M are evaluated at two different load scenarios. In addition to that, technical and economical analyses are examined for various combinations of DGs and shunt capacitors. The proposed methodology is successfully demonstrated on 33-bus and 85-bus radial networks and the obtained numerical outcomes validate the suitability, importance and effectiveness to identify locations as well as sizes of DGs and shunt capacitors.

  4. Particle swarm optimization algorithm for simultaneous optimal placement and sizing of shunt active power conditioner (APC) and shunt capacitor inharmonic distorted distribution system

    Institute of Scientific and Technical Information of China (English)

    Mohammadi Mohammad

    2017-01-01

    Due to development of distribution systems and increase in electricity demand, the use of capacitor banks increases. From the other point of view, nonlinear loads generate and inject considerable harmonic currents into power system. Under this condition if capacitor banks are not properly selected and placed in the power system, they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels. With attention of disadvantages of passive filters, such as occurring resonance, nowadays the usage of this type of harmonic compensator is restricted. On the other side, one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion, performs power factor correction, and improves the overall power quality as active power conditioner (APC). Therefore, the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition. This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics. The algorithm is based on particle swarm optimization (PSO). The objective function includes the cost of power losses, energy losses and those of the capacitor banks and APCs.

  5. Derivative load voltage and particle swarm optimization to determine optimum sizing and placement of shunt capacitor in improving line losses

    Directory of Open Access Journals (Sweden)

    Mohamed Milad Baiek

    2016-12-01

    Full Text Available The purpose of this research is to study optimal size and placement of shunt capacitor in order to minimize line loss. Derivative load bus voltage was calculated to determine the sensitive load buses which further being optimum with the placement of shunt capacitor. Particle swarm optimization (PSO was demonstrated on the IEEE 14 bus power system to find optimum size of shunt capacitor in reducing line loss. The objective function was applied to determine the proper placement of capacitor and get satisfied solutions towards constraints. The simulation was run over Matlab under two scenarios namely base case and increasing 100% load. Derivative load bus voltage was simulated to determine the most sensitive load bus. PSO was carried out to determine the optimum sizing of shunt capacitor at the most sensitive bus. The results have been determined that the most sensitive bus was bus number 14 for the base case and increasing 100% load. The optimum sizing was 8.17 Mvar for the base case and 23.98 Mvar for increasing load about 100%. Line losses were able to reduce approximately 0.98% for the base case and increasing 100% load reduced about 3.16%. The proposed method was also proven as a better result compared with harmony search algorithm (HSA method. HSA method recorded loss reduction ratio about 0.44% for the base case and 2.67% when the load was increased by 100% while PSO calculated loss reduction ratio about 1.12% and 4.02% for the base case and increasing 100% load respectively. The result of this study will support the previous study and it is concluded that PSO was successfully able to solve some engineering problems as well as to find a solution in determining shunt capacitor sizing on the power system simply and accurately compared with other evolutionary optimization methods.

  6. Location and determination of steps of capacitors in shunt for distribution power lines; Localizacion y determinacion de pasos de capacitores en derivacion para lineas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Pampin Vergara, Gabriela; Sarmiento Uruchurtu, Hector [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    A methodology is presented to determine the optimal location of the capacitor banks in shunt for distribution networks. The proposed tool allows knowing the bank type to install (fixed, disconnect able or of pass), as well as the electrical parameters of the feeder and the economic benefit that the banks of capacitors represent, with a minimum of input data. Its development in a spreadsheet allows the analysis of numerous alternatives in an easy way. The method is based on that the structure of the feeders of distribution is, generally, of radial type, with which, and by means of an iterative process, the optimal location of the capacitor banks in shunt is looked for. The type of bank is determined based of the demand, as well as the number of steps. The results of the analysis in feeders of the network of the central area are shown. [Spanish] Se presenta una metodologia para determinar la localizacion optima de los bancos de capacitores en derivacion en redes de distribucion. La herramienta propuesta permite conocer el tipo de banco a instalar (fijo, desconcectable o de paso), asi como los parametros electricos del alimentador y el beneficio economico que representan los bancos de capacitores, con un minimo de datos de entrada. Su desarrollo en una hoja de calculo permite el analisis de numerosas alternativas de manera facil. El metodo se basa en que la estructura de los alimentadores de distribucion es, por lo general, de tipo radial, con lo cual, y por medio de un proceso iterativo, se busca la localizacion optima de los bancos de capacitores en derivacion. Se determina el tipo de banco en funcion de la demanda, asi como el numero de pasos. Se muestran resultados del analisis en alimentadores de la red del area central.

  7. Protection of large capacitor banks

    International Nuclear Information System (INIS)

    Sprott, J.C.; Lovell, T.W.

    1982-06-01

    Large capacitor banks, as used in many pulsed plasma experiments, are subject to catastrophic failure in the event of a short in the output or in an individual capacitor. Methods are described for protecting such banks to minimize the damage and down-time caused by such a failure

  8. Multi-step capacitor discharges as an RF generator

    International Nuclear Information System (INIS)

    Hotta, Eiki; Yamamoto, Shunji; Ishii, Shozo; Hayashi, Izumi

    1979-01-01

    A variety of methods have been developed for large output radio frequency (RF) generators to heat and stabilize high temperature plasma. As the generators for this purpose, capacitor discharge, cable discharge, and oscillation with electronic tubes are considered. Here, a new RF generator is reported, which utilizes capacitor discharge to extract heavy current, and solves the difficulty of short duration by employing multistep discharges. The authors solved the problem of frequency decrease in capacitor discharge by cutting off the unnecessary capacitors reasonably from the load circuit, using the additional circuit for shunting current and vacuum gap switches. The vacuum gap switches and the trigger system are described together with the RF generator manufactured. The generator was fabricated to be rather compact for its large output and simple in circuitry as compared with conventional oscillator systems. The shortcomings are frequency variation and the improper phase of switching the next step in to cause instability, when the load change occurs. It would be difficult to operate the generator in a RF range of more than about 10 MHz due to jitter of the vacuum gap switches and others. (Wakatsuki, Y.)

  9. Resonant Electromagnetic Shunt Damping of Flexible Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker

    2016-01-01

    Electromagnetic transducers convert mechanical energy to electrical energy and vice versa. Effective passive vibration damping of flexible structures can therefore be introduced by shunting with an accurately calibrated resonant electrical network thatcontains a capacitor to create the desired...

  10. Experimental analysis of an MIM capacitor with a concave shield

    International Nuclear Information System (INIS)

    Liu Lintao; Yu Mingyan; Wang Jinxiang

    2009-01-01

    A novel shielding scheme is developed by inserting a concave shield between a metal-insulator-metal (MIM) capacitor and the silicon substrate. Chip measurements reveal that the concave shield improves the quality factor by 11% at 11.8 GHz and 14% at 18.8 GHz compared with an unshielded MIM capacitor. It also alleviates the effect on shunt capacitance between the bottom plate of the MIM capacitor and the shield layer. Moreover, because the concave shields simplify substrate modeling, a simple circuit model of the MIM capacitor with concave shield is presented for radio frequency applications.

  11. Performance analysis of a simple shunt and series compensated six-phase self-excited induction generator for stand-alone renewable energy generation

    International Nuclear Information System (INIS)

    Singh, G.K.; Kumar, A. Senthil; Saini, R.P.

    2011-01-01

    This paper describes a new generalized and efficient model for performance analysis of a six-phase self-excited induction generator (SPSEIG) with three capacitor excitation topologies; simple shunt, short shunt and long shunt. Mathematical model of SPSEIG is formulated using nodal admittance method based on graph theory. Attention is focused on the influence of the different capacitor connections on the generator overload and output power capabilities. The generator voltage with simple shunt excitation connection collapses when it is overloaded while with either the short shunt or long shunt excitation connection; generator is able to sustain the load at a lower operating voltage and larger load current. The matrix equation developed by nodal admittance method is solved by Genetic Algorithm (GA) technique to predetermine the steady-state performance of SPSEIG. The experimental and theoretical results are found to be in good agreement.

  12. Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study

    Directory of Open Access Journals (Sweden)

    Oramus Piotr

    2015-09-01

    Full Text Available Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.

  13. A new electromagnetic shunt damping treatment and vibration control of beam structures

    International Nuclear Information System (INIS)

    Niu Hongpan; Zhang Xinong; Xie Shilin; Wang Pengpeng

    2009-01-01

    In this paper a new class of shunted electromagnetic damping treatment is proposed: a non-contact electromagnetic shunt damper (NC-EMSD). The NC-EMSD consists of an electromagnet attached to a host structure, a permanent magnet attached to the fixed boundary and an electrical impedance connected to the terminals of the electromagnet. The electromagnet and the shunt impedance constitute a closed circuit. When the structure vibrates, an induced electromotive force will be produced and results in the electromagnetic force as damping force, which can suppress the vibration of the structure. The model of NC-EMSD is built up based on the equivalent current method. The governing equations of the beam with NC-EMSD are established using Hamilton's principle. The capacitor-matching-inductance (CMI) method and the negative resistive capacitor-matching-inductance (NR-CMI) method are proposed, respectively. Then the vibration control of a cantilever beam with NC-EMSD is simulated and measured by CMI and NR-CMI control methods, respectively. The results show that both the CMI and NR-CMI can attenuate the vibration effectively, and the NR-CMI provides much better control performance than that by CMI. It is indicated as well from the studies that the decrease of either the gap between the magnet pair or the resistance of the shunt impedance contributes to the improvement of control performance

  14. Capacitor Discharge - A Capacitor Tutorial [video

    OpenAIRE

    Naval Postgraduate School Physics

    2014-01-01

    NPS Physics Physics Demonstrations Here's a capacitor discharge demonstrated by physicist Dr. Dernardo. Dr. D gives a nice capacitor lesson along with some fireworks. Charging and Discharging a Capacitor is dangerous. Do not try this at home. Dr. Bruce Denardo uses eleven 9V batteries, connected in series for a total of 99 creating a pretty large spark.

  15. Fault Diagnosis for Compensating Capacitors of Jointless Track Circuit Based on Dynamic Time Warping

    Directory of Open Access Journals (Sweden)

    Wei Dong

    2014-01-01

    Full Text Available Aiming at the problem of online fault diagnosis for compensating capacitors of jointless track circuit, a dynamic time warping (DTW based diagnosis method is proposed in this paper. Different from the existing related works, this method only uses the ground indoor monitoring signals of track circuit to locate the faulty compensating capacitor, not depending on the shunt current of inspection train, which is an indispensable condition for existing methods. So, it can be used for online diagnosis of compensating capacitor, which has not yet been realized by existing methods. To overcome the key problem that track circuit cannot obtain the precise position of the train, the DTW method is used for the first time in this situation to recover the function relationship between receiver’s peak voltage and shunt position. The necessity, thinking, and procedure of the method are described in detail. Besides the classical DTW based method, two improved methods for improving classification quality and reducing computation complexity are proposed. Finally, the diagnosis experiments based on the simulation model of track circuit show the effectiveness of the proposed methods.

  16. Simulation and analysis of transient over voltages due to capacitor banks switching

    International Nuclear Information System (INIS)

    Jadid, Sh.; Yazdanpanah, D.

    2002-01-01

    The switching of any capacitor bank produces over voltages. Transient overvoltage will always occur in the switching device, the switching of shunt capacitor bank has become the most common source of transient voltage on power systems. Transient over voltages due to switching the capacitor bands hurt not only to the capacitor banks, but also to other equipment, such as circuit breakers and transformers. Several methods are available for reducing energising transients. These devices include pre-insertion resistors, pre-insertion inductors,synchronous closing, and MOV arresters. However, not all are practical or economical. The other important problem is existence of capacitor banks in presence of harmonics.Capacitors do not produce harmonics;however,the addition of capacitors to the electrical system will change the frequency response characteristics of the system will change the frequency response characteristics of the system, and in some cases can result in magnification of the voltage and current distortion in the system. In other word in presence of harmonic-producing loads,the capacitors used for power factor correction,may cause parallel resonance with the system inductance, so they increase the total harmonic distortion of voltage and current waveforms

  17. Protective systems and its protective switching elements on local failures of large slow-capacitor bank system

    International Nuclear Information System (INIS)

    Hasegawa, Mitsuo; Inoue, Kunikazu; Ueno, Isao.

    1994-01-01

    In various applications of pulsed power technologies, large capacitor bank systems are used to feed high current impulse to different experimental devices. The accidental electric breakdown in one of the capacitors in a parallel connection of the large bank may result in serious damages such as mechanical explosion and oil effusion or fire. In most fast banks, each unit capacitor has an output gap switch, which is expected to decouple the capacitors one another. However, no such special element is adopted usually in the slow bank system, partly because of the economical consideration. We have developed a novel and inexpensive protective element for these relatively slow capacitor banks, utilizing a concept of the enclosed type of the fast breakers. The principle of the operation of the protection elements is verified by a simulation experiment. Their practical effectiveness is also successfully demonstrated in the application to the system of the pulsed high magnetic field generator. (author)

  18. A new emergency control for voltage stability utilizing the time overvoltage capability of large shunt capacitor banks

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W; Vanleuven, Allen L; Nordstrom, Jerry M [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    Electric utilities have become increasing concerned with the possibility of voltage instability and voltage collapse. Although many countermeasures are a possible, control based countermeasures are often the most cost effective. Voltage collapse is often only a threat during unusual conditions such as very high load and major outages. For these low probability conditions, low cost emergency controls may be the only cost effective countermeasures. This paper provides details on a prototype installation by the Bonneville Power Administration of a new low cost emergency control for voltage stability named CAPS (CAPacitor bank series group Shorting). (author) 6 refs., 5 figs.

  19. Wall-plug efficiency analysis of semi-active piezoelectric shunt damping systems

    Czech Academy of Sciences Publication Activity Database

    Václavík, Jan; Kodejška, M.; Mokrý, Pavel

    2014-01-01

    Roč. 20, September (2014), 1077546314548910 ISSN 1077-5463 R&D Projects: GA MŠk(CZ) LO1206; GA ČR GA13-10365S Institutional support: RVO:61389021 Keywords : Piezoelectric shunt damping * vibration isolation * negative capacitor * wall-plug efficiency * mechanical power measurement * power supply optimization Subject RIV: BI - Acoustics Impact factor: 4.355, year: 2013 http://jvc.sagepub.com/content/early/2014/09/17/1077546314548910

  20. Principal considerations in large energy-storage capacitor banks

    International Nuclear Information System (INIS)

    Kemp, E.L.

    1976-01-01

    Capacitor banks storing one or more megajoules and costing more than one million dollars have unique problems not often found in smaller systems. Two large banks, Scyllac at Los Alamos and Shiva at Livermore, are used as models of large, complex systems. Scyllac is a 10-MJ, 60-kV theta-pinch system while Shiva is a 20-MJ, 20-kV energy system for laser flash lamps. A number of design principles are emphasized for expediting the design and construction of large banks. The sensitive features of the charge system, the storage system layout, the switching system, the transmission system, and the design of the principal bank components are presented. Project management and planning must involve a PERT chart with certain common features for all the activities. The importance of the budget is emphasized

  1. Electrically tuned super-capacitors

    OpenAIRE

    Chowdhury, Tazima S.; Grebel, Haim

    2015-01-01

    Fast charging and discharging of large amounts of electrical energy make super-capacitors ideal for short-term energy storage [1-5]. In its simplest form, the super-capacitor is an electrolytic capacitor made of an anode and a cathode immersed in an electrolyte. As for an ordinary capacitor, minimizing the charge separation distance and increasing the electrode area increase capacitance. In super-capacitors, charge separation is of nano-meter scale at each of the electrode interface (the Helm...

  2. Wall-plug efficiency analysis of semi-active piezoelectric shunt damping systems

    Czech Academy of Sciences Publication Activity Database

    Václavík, Jan; Kodejška, M.; Mokrý, Pavel

    2016-01-01

    Roč. 22, č. 11 (2016), s. 2582-2590 ISSN 1077-5463 R&D Projects: GA MŠk(CZ) LO1206; GA ČR GA13-10365S Institutional support: RVO:61389021 Keywords : Piezoelectric shunt damping * vibration isolation * negative capacitor * wall-plug efficiency * mechanical power measurement * power supply optimization Subject RIV: BI - Acoustics Impact factor: 2.101, year: 2016 http://journals.sagepub.com/doi/abs/10.1177/1077546314548910

  3. Reliability of high-voltage pulse capacitors operating in large energy storages

    International Nuclear Information System (INIS)

    Kuchinskij, G.S.; Fedorova, V.S.; Shilin, O.V.

    1982-01-01

    To improve the reliability of pulse capacitors operating in capacitive energy storages, processes, resulting in break-down of capacitor insulation were investigated. A statistic model of failures was constructed and reliability of real capacitors, functioning at operating electric intensity Usub(oper) equal 70 kV/mm and at elevated intensity 90 kV/mm was calculated. Results of testing the IK50-ZU4 capacitor are given. The form of the capacitor service life distribution function was specified. To provide and confirm the assigned capacitor reliability, it is necessary to speed up tests at a higher voltage (1.3-1.5) Usub(oper). To improve the capacitor reliability, it is advisable to conduct acceptance tests, which include hold at increased constant voltage (1.3-1.5) Usub(oper) during 1-3 min and the effect of pulses of increased voltage (1.2-1.3) Usub(oper) with the pulse shape corresponding to operating conditions

  4. Development of Real Time Implementation of 5/5 Rule based Fuzzy Logic Controller Shunt Active Power Filter for Power Quality Improvement

    Science.gov (United States)

    Puhan, Pratap Sekhar; Ray, Pravat Kumar; Panda, Gayadhar

    2016-12-01

    This paper presents the effectiveness of 5/5 Fuzzy rule implementation in Fuzzy Logic Controller conjunction with indirect control technique to enhance the power quality in single phase system, An indirect current controller in conjunction with Fuzzy Logic Controller is applied to the proposed shunt active power filter to estimate the peak reference current and capacitor voltage. Current Controller based pulse width modulation (CCPWM) is used to generate the switching signals of voltage source inverter. Various simulation results are presented to verify the good behaviour of the Shunt active Power Filter (SAPF) with proposed two levels Hysteresis Current Controller (HCC). For verification of Shunt Active Power Filter in real time, the proposed control algorithm has been implemented in laboratory developed setup in dSPACE platform.

  5. Design considerations for application of shunt capacitors in Heavy Water Plant (Tuticorin) (Paper No. 5.8)

    International Nuclear Information System (INIS)

    Subramanian, A.R.; Palani, R.A.A.; Thomson, J.

    1992-01-01

    The average load requirement of Heavy Water Plant, Tuticorin was 11.13 MVA with the power factor of 0.86, the calculated KVAR rating was 5,600. To improve the power factor from 0.86 to 0.98 the reactive compensation calculated was around 4200 KVAR. Accordingly a new 3.3 K.V. 4200 KVAR auto switching capacitor bank was installed at HWP(T) for power factor improvement. The paper describes the design considerations of the capacitor bank. (author)

  6. Mechanical states in wound capacitors

    International Nuclear Information System (INIS)

    Allen, J.J.; Reuter, R.C. Jr.

    1989-01-01

    The winding process is encountered frequently in manufacturing, such as winding of polymer films and paper, laminated pressure vessel construction, and the manufacture of wound capacitors. The winding of capacitors will typically involve hundreds of plies of conductor and dielectric wound over a core. Due to the large number of layers, the calculation of the mechanical studies within a wound capacitor is a significant computational task. The focus of Part II of this paper is the formulation and application of optimization techniques for the design of wound capacitors. The design criteria to be achieved is a specified uniform wound tension in a capacitor. The paper will formulate an optimization statement of the wound capacitor design problem, develop a technique for reducing the numerical calculation required to repeatedly analyze the capacitor as required by the optimization algorithm, and apply the technique to an example. 4 refs., 13 figs., 4 tabs

  7. Subacute bacterial endocarditis and subsequent shunt nephritis from ventriculoatrial shunting 14 years after shunt implantation

    DEFF Research Database (Denmark)

    Burström, Gustav; Andresen, Morten; Bartek, Jiri Jr.

    2014-01-01

    of causing subacute bacterial endocarditis and subsequent shunt nephritis. The patient was successfully treated with antibiotics combined with ventriculoatrial shunt removal and endoscopic third ventriculocisternostomy (VCS). This case illustrates the nowadays rare, but potentially severe complication...... of subacute bacterial endocarditis and shunt nephritis. It also exemplifies the VCS as an alternative to implanting foreign shunt systems for CSF diversion....

  8. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  9. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    Science.gov (United States)

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  10. Shunt occlusion for portosystemic shunt syndrome related refractory hepatic encephalopathy-A single-center experience in 21 patients from Kerala.

    Science.gov (United States)

    Philips, Cyriac Abby; Kumar, Lijesh; Augustine, Philip

    2017-09-01

    Large spontaneous portosystemic shunts (SPSS) are seen in a subset of patients with liver disease and medically refractory recurrent/persistent hepatic encephalopathy (MRHE). Shunt occlusion has been shown to improve clinical outcomes. We retrospectively analyzed patient characteristics, SPSS attributes, procedural features, baseline clinical and investigational parameters, neurological outcomes, adverse effects (procedure and portal hypertension related), and risk factors predicting outcomes in liver disease patients undergoing shunt occlusion procedure for MRHE. Between October 2016 and July 2017, 21 patients (Child-Pugh score, CTP 6 to 13) with mean model of end-stage liver disease (MELD) and MELD-sodium scores 15.7 and 19.3 respectively with MRHE [3-cirrhotic Parkinsonism (CP)] were diagnosed to have single or multiple large SPSSs. A total of 29 shunts were occluded (1 surgical, 20 non-surgical). Recurrent and persistent HE and CP markedly improved in the short (n=20, 1 to 3 months), intermediate (n=12, 3 to 6 months), and long (n=7, 6 to 9 months) follow up. None had spontaneous or persistent HE at a median follow up 105 (30 to 329) days (p11 predicted mortality post shunt occlusion (p=0.04). Embolization of large SPSS in liver disease patients with MRHE and modestly preserved liver function is safe and efficacious and associated with improved quality of life and can function as a bridge to liver transplantation in accurately selected patients.

  11. Capacitors.

    Science.gov (United States)

    Trotter, Donald M., Jr.

    1988-01-01

    Presents a historical backdrop for a discussion of capacitor design and function. Discusses the production, importance, and function of two types of miniature capacitors; electrolytic and multilayer ceramic capacitors. Describes the function of these miniature capacitors in comparison to the Leyden jar, a basic demonstration of capacitance. (CW)

  12. Suspended graphene variable capacitor

    OpenAIRE

    AbdelGhany, M.; Mahvash, F.; Mukhopadhyay, M.; Favron, A.; Martel, R.; Siaj, M.; Szkopek, T.

    2016-01-01

    The tuning of electrical circuit resonance with a variable capacitor, or varactor, finds wide application with the most important being wireless telecommunication. We demonstrate an electromechanical graphene varactor, a variable capacitor wherein the capacitance is tuned by voltage controlled deflection of a dense array of suspended graphene membranes. The low flexural rigidity of graphene monolayers is exploited to achieve low actuation voltage in an ultra-thin structure. Large arrays compr...

  13. Intrahepatic porto-hepatic venous shunts in Rendu-Osler-Weber disease: imaging demonstration

    International Nuclear Information System (INIS)

    Matsumoto, Shunro; Mori, Hiromu; Yamada, Yasunari; Hayashida, Tomoko; Hori, Yuzo; Kiyosue, Hiro

    2004-01-01

    This study describes the imaging features of the intrahepatic portohepatic venous (PHV) shunt, which is a potential cause of portosystemic encephalopathy in Rendu-Osler-Weber disease. Six patients with Rendu-Osler-Weber disease (two men, four women; age range 42-73 years) were retrospectively studied. There were two from one family and three from another family. Of these patients, one was diagnosed with definitive portosystemic encephalopathy because of a psychiatric disorder. We retrospectively reviewed the radiological examinations, including abdominal angiography (n=6), three-phase dynamic helical computed tomography (CT; n=3), and conventional enhanced CT (n=1). In one patient, CT during angiography and CT angioportography were also performed. Evaluation was placed on the imaging features of intrahepatic PHV shunts. On angiography, intrahepatic PHV shunts showing multiple and small shunts <5 mm in diameter in an apparent network were detected in all patents. In two patients, a large shunt with a size of either 7 or 10 mm was associated. These intrahepatic PHV shunts were predominantly distributed in the peripheral parenchyma. Intrahepatic PHV shunts would be characterized by small and multiple shunts in an apparent network on the periphery with or without a large shunt. (orig.)

  14. Direct Mismatch Characterization of femto-Farad Capacitors

    KAUST Repository

    Omran, Hesham

    2015-08-17

    Reducing the capacitance of programmable capacitor arrays, commonly used in analog integrated circuits, is necessary for low-energy applications. However, limited mismatch data is available for small capacitors. We report mismatch measurement for a 2fF poly-insulator-poly (PIP) capacitor, which is the smallest reported PIP capacitor to the best of the authors’ knowledge. Instead of using complicated custom onchip circuitry, direct mismatch measurement is demonstrated and verified using Monte Carlo Simulations and experimental measurements. Capacitive test structures composed of 9 bit programmable capacitor arrays (PCAs) are implemented in a low-cost 0:35m CMOS process. Measured data is compared to mismatch of large PIP capacitors, theoretical models, and recently published data. Measurement results indicate an estimated average relative standard deviation of 0.43% for the 2fF unit capacitor, which is better than the reported mismatch of metal-oxide-metal (MOM) fringing capacitors implemented in an advanced 32nm CMOS process.

  15. Direct Mismatch Characterization of femto-Farad Capacitors

    KAUST Repository

    Omran, Hesham; Elafandy, Rami T.; Arsalan, Muhammad; Salama, Khaled N.

    2015-01-01

    Reducing the capacitance of programmable capacitor arrays, commonly used in analog integrated circuits, is necessary for low-energy applications. However, limited mismatch data is available for small capacitors. We report mismatch measurement for a 2fF poly-insulator-poly (PIP) capacitor, which is the smallest reported PIP capacitor to the best of the authors’ knowledge. Instead of using complicated custom onchip circuitry, direct mismatch measurement is demonstrated and verified using Monte Carlo Simulations and experimental measurements. Capacitive test structures composed of 9 􀀀 bit programmable capacitor arrays (PCAs) are implemented in a low-cost 0:35m CMOS process. Measured data is compared to mismatch of large PIP capacitors, theoretical models, and recently published data. Measurement results indicate an estimated average relative standard deviation of 0.43% for the 2fF unit capacitor, which is better than the reported mismatch of metal-oxide-metal (MOM) fringing capacitors implemented in an advanced 32nm CMOS process.

  16. Matching Properties of Femtofarad and Sub-Femtofarad MOM Capacitors

    KAUST Repository

    Omran, Hesham

    2016-04-21

    Small metal-oxide-metal (MOM) capacitors are essential to energy-efficient mixed-signal integrated circuit design. However, only few reports discuss their matching properties based on large sets of measured data. In this paper, we report matching properties of femtofarad and sub-femtofarad MOM vertical-field parallel-plate capacitors and lateral-field fringing capacitors. We study the effect of both the finger-length and finger-spacing on the mismatch of lateral-field capacitors. In addition, we compare the matching properties and the area efficiency of vertical-field and lateral-field capacitors. We use direct mismatch measurement technique, and we illustrate its feasibility using experimental measurements and Monte Carlo simulations. The test-chips are fabricated in a 0.18 \\\\mutext{m} CMOS process. A large number of test structures is characterized (4800 test structures), which improves the statistical reliability of the extracted mismatch information. Despite conventional wisdom, extensive measurements show that vertical-field and lateral-field MOM capacitors have the same matching properties when the actual capacitor area is considered. Measurements show that the mismatch depends on the capacitor area but not on the spacing; thus, for a given mismatch specification, the lateral-field MOM capacitor can have arbitrarily small capacitance by increasing the spacing between the capacitor fingers, at the expense of increased chip area.

  17. Matching Properties of Femtofarad and Sub-Femtofarad MOM Capacitors

    KAUST Repository

    Omran, Hesham; Alahmadi, Hamzah; Salama, Khaled N.

    2016-01-01

    Small metal-oxide-metal (MOM) capacitors are essential to energy-efficient mixed-signal integrated circuit design. However, only few reports discuss their matching properties based on large sets of measured data. In this paper, we report matching properties of femtofarad and sub-femtofarad MOM vertical-field parallel-plate capacitors and lateral-field fringing capacitors. We study the effect of both the finger-length and finger-spacing on the mismatch of lateral-field capacitors. In addition, we compare the matching properties and the area efficiency of vertical-field and lateral-field capacitors. We use direct mismatch measurement technique, and we illustrate its feasibility using experimental measurements and Monte Carlo simulations. The test-chips are fabricated in a 0.18 \\mutext{m} CMOS process. A large number of test structures is characterized (4800 test structures), which improves the statistical reliability of the extracted mismatch information. Despite conventional wisdom, extensive measurements show that vertical-field and lateral-field MOM capacitors have the same matching properties when the actual capacitor area is considered. Measurements show that the mismatch depends on the capacitor area but not on the spacing; thus, for a given mismatch specification, the lateral-field MOM capacitor can have arbitrarily small capacitance by increasing the spacing between the capacitor fingers, at the expense of increased chip area.

  18. Cross-species functionality of pararetroviral elements driving ribosome shunting.

    Directory of Open Access Journals (Sweden)

    Mikhail M Pooggin

    Full Text Available BACKGROUND: Cauliflower mosaic virus (CaMV and Rice tungro bacilliform virus (RTBV belong to distinct genera of pararetroviruses infecting dicot and monocot plants, respectively. In both viruses, polycistronic translation of pregenomic (pg RNA is initiated by shunting ribosomes that bypass a large region of the pgRNA leader with several short (sORFs and a stable stem-loop structure. The shunt requires translation of a 5'-proximal sORF terminating near the stem. In CaMV, mutations knocking out this sORF nearly abolish shunting and virus viability. METHODOLOGY/PRINCIPAL FINDINGS: Here we show that two distant regions of the CaMV leader that form a minimal shunt configuration comprising the sORF, a bottom part of the stem, and a shunt landing sequence can be replaced by heterologous sequences that form a structurally similar configuration in RTBV without any dramatic effect on shunt-mediated translation and CaMV infectivity. The CaMV-RTBV chimeric leader sequence was largely stable over five viral passages in turnip plants: a few alterations that did eventually occur in the virus progenies are indicative of fine tuning of the chimeric sequence during adaptation to a new host. CONCLUSIONS/SIGNIFICANCE: Our findings demonstrate cross-species functionality of pararetroviral cis-elements driving ribosome shunting and evolutionary conservation of the shunt mechanism. We are grateful to Matthias Müller and Sandra Pauli for technical assistance. This work was initiated at Friedrich Miescher Institute (Basel, Switzerland. We thank Prof. Thomas Boller for hosting the group at the Institute of Botany.

  19. Multilayer capacitors, method for making multilayer capacitors

    Science.gov (United States)

    Ma, Beihai; Balachandran, Uthamalingam

    2018-03-06

    The invention provides a stacked capacitor configuration comprising subunits each with a thickness of as low as 20 microns. Also provided is combination capacitor and printed wire board wherein the capacitor is encapsulated by the wire board. The invented capacitors are applicable in micro-electronic applications and high power applications, whether it is AC to DC or DC to AC, or DC to DC.

  20. Ventriculoperitoneal Shunt Migration

    Directory of Open Access Journals (Sweden)

    Justin P Puller

    2017-01-01

    Full Text Available History of present illness: A 40-year-old female presented to our ED with left upper abdominal pain and flank pain. The pain had begun suddenly 2 hours prior when she was reaching into a freezer to get a bag of frozen vegetables. She described the pain as sharp, constant, severe, and worse with movements and breathing. The pain radiated to the left shoulder. On review of systems, the patient had mild dyspnea and nausea. She denied fever, chills, headache, vision changes, vomiting, or urinary symptoms. Her medical history was notable for obstructive sleep apnea, gastroesophageal reflux disease, arthritis, fibromyalgia, depression, obesity, and idiopathic intracranial hypertension. For the latter, she had a VP (ventriculoperitoneal shunt placed 14 years prior to this visit. She had a history of 2 shunt revisions, the most recent 30 days before this ED visit. Significant findings: An immediate post-op abdominal x-ray performed after the patient’s VP shunt revision 30 days prior to this ED visit reveals the VP shunt tip in the mid abdomen. A CT of the abdomen performed on the day of the ED visit reveals the VP shunt tip interposed between the spleen and the diaphragm. Discussion: VP shunts have been reported to migrate to varied locations in the thorax and abdomen. Incidence of abdominal complications of VP shunt placement ranges from 10%-30%, and can include pseudocyst formation, migration, peritonitis, CSF ascites, infection, and viscus perforation. Incidence of distal shunt migration is reported as 10%, and most previously reported cases occurred in pediatric patients.1 A recent retrospective review cited BMI greater than thirty and previous shunt procedure as risk factors for distal shunt migration.2 The patient in the case presented had a BMI of 59 and 3 previous shunt procedures.

  1. High density energy storage capacitor

    International Nuclear Information System (INIS)

    Whitham, K.; Howland, M.M.; Hutzler, J.R.

    1979-01-01

    The Nova laser system will use 130 MJ of capacitive energy storage and have a peak power capability of 250,000 MW. This capacitor bank is a significant portion of the laser cost and requires a large portion of the physical facilities. In order to reduce the cost and volume required by the bank, the Laser Fusion Program funded contracts with three energy storage capacitor producers: Aerovox, G.E., and Maxwell Laboratories, to develop higher energy density, lower cost energy storage capacitors. This paper describes the designs which resulted from the Aerovox development contract, and specifically addresses the design and initial life testing of a 12.5 kJ, 22 kV capacitor with a density of 4.2 J/in 3 and a projected cost in the range of 5 cents per joule

  2. Pathophysiology of shunt dysfunction in shunt treated hydrocephalus

    DEFF Research Database (Denmark)

    Blegvad, C.; Skjolding, A D; Broholm, H

    2013-01-01

    We hypothesized that shunt dysfunction in the ventricular catheter and the shunt valve is caused by different cellular responses. We also hypothesized that the cellular responses depend on different pathophysiological mechanisms....

  3. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2012-02-01

    OBJECTIVES: Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts. METHODS: A retrospective chart review was conducted on 25 patients treated for IIH between 2001 and 2009. Age, sex, clinical presentation, methods of treatment and failure rates were recorded. RESULTS: Seventy-two per cent were treated initially with LP shunts. Failure rate was 11% in this group. Neuronavigation-assisted VP shunts were used to treat 28%. In this group, the failure rate was 14%. CONCLUSION: Our experience indicates that both LP shunts and VP shuts are effective in controlling all the clinical manifestations of IIH in the immediate postoperative period. Failure rates are slightly higher for VP shunts (14%) than LP shunts (11%). However, revision rates are higher with LP shunts (60%) than with VP shunts (30%).

  4. Capacitor performance limitations in high power converter applications

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Holbøll, Joachim; Rasmussen, Tonny Wederberg

    2013-01-01

    High voltage low inductance capacitors are used in converters as HVDC-links, snubber circuits and sub model (MMC) capacitances. They facilitate the possibility of large peak currents under high frequent or transient voltage applications. On the other hand, using capacitors with larger equivalent...... series inductances include the risk of transient overvoltages, with a negative effect on life time and reliability of the capacitors. These allowable limits of such current and voltage peaks are decided by the ability of the converter components, including the capacitors, to withstand them over...... the expected life time. In this paper results are described from investigations on the electrical environment of these capacitors, including all the conditions they would be exposed to, thereby trying to find the tradeoffs needed to find a suitable capacitor. Different types of capacitors with the same voltage...

  5. Nanohybrid capacitor: the next generation electrochemical capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Naoi, K. [Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8558 (Japan)

    2010-10-15

    Conventional electric double layer capacitors (EDLC) designed with two symmetrical activated carbon electrodes can deliver substantially more power than similar size Li-ion batteries. There is presently a major effort to increase the energy density of EDLC s up to a target value in the vicinity of 20-30 Wh kg{sup -1}.The present review article deals with the recent contributions to get this high energy density and new approaches that have been made to increase the withstanding voltage of the EDLCs. Important alternative approach to meet this goal that is under serious investigation is to develop an asymmetric (hybrid) capacitors. Hybrid capacitor systems are the promising approach to meet the goal to effectively increase the energy density. The investigation is to develop hybrid capacitors has been initiated by Li-ion capacitors. And, now Nanohybrid capacitor certainly achieves as high energy density as Li-ion capacitors with higher stability, higher safety and higher productivity. This is the new lithium-ion based hybrid capacitor using the lithium titanate (Li{sub 4}Ti{sub 5}O{sub 12}) negative intercalation electrode that can operate at unusually high current densities. The high-rate Li{sub 4}Ti{sub 5}O{sub 12} negative electrode has a unique nano-structure consisting of unusually small nano-crystalline Li{sub 4}Ti{sub 5}O{sub 12} nucleated and grafted onto carbon nano-fiber anchors (nc-Li{sub 4}Ti{sub 5}O{sub 12}/CNF). (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  6. A compact 100 kV high voltage glycol capacitor.

    Science.gov (United States)

    Wang, Langning; Liu, Jinliang; Feng, Jiahuai

    2015-01-01

    A high voltage capacitor is described in this paper. The capacitor uses glycerol as energy storage medium, has a large capacitance close to 1 nF, can hold off voltages of up to 100 kV for μs charging time. Allowing for low inductance, the capacitor electrode is designed as coaxial structure, which is different from the common structure of the ceramic capacitor. With a steady capacitance at different frequencies and a high hold-off voltage of up to 100 kV, the glycol capacitor design provides a potential substitute for the ceramic capacitors in pulse-forming network modulator to generate high voltage pulses with a width longer than 100 ns.

  7. Ventriculo-pleural shunt patency study

    International Nuclear Information System (INIS)

    Yeates, K.

    2000-01-01

    Full text: A twenty-four year old male was admitted to hospital complaining of headaches, drowsiness and blurred vision. He suffered from congenital hydrocephalus and had had a ventriculo-peritoneal shunt inserted in infancy. This had undergone many revisions due to persistent peritoneal infections and had recently been replaced with a ventriculo-pleural shunt. The symptoms described suggested shunt blockage and he was referred for a Shunt Patency Study. The current shunt is a HAKIM Programmable Valve Shunt System and the opening pressure was 12cm of CSF (within the normal range). Forty megabecquerels of filtered 99 Tc m O 4 was injected into the pre-chamber of the shunt. Serial images and counts were obtained for twenty-five minutes after the injection. The images showed the tracer flowing from the shunt within the first ten minutes. At twenty minutes almost all of the tracer had drained from the shunt and was present in the right pleural cavity, indicating shunt patency. This study is presented to demonstrate the appearances of a normally functioning, but rarely seen Ventriculo-Pleural CSF Shunt. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Efficient Approach for Harmonic Resonance Identification of Large Wind Power Plants

    DEFF Research Database (Denmark)

    Ebrahimzadeh, Esmaeil; Blaabjerg, Frede; Wang, Xiongfei

    2016-01-01

    Unlike conventional power systems where the resonance frequencies are mainly determined by the passive components parameters, large Wind Power Plants (WPPs) may introduce additional harmonic resonances because of the interactions of the wideband control systems of power converters with each other...... and with passive components. This paper presents an efficient approach for identification of harmonic resonances in large WPPs containing power electronic converters, cable, transformer, capacitor banks, shunt reactors, etc. The proposed approach introduces a large WPP as a Multi-Input Multi-Output (MIMO) control...... system by considering the linearized models of the inner control loops of grid-side converters. Therefore, the resonance frequencies of the WPP resulting from passive components and the control loop interactions are identified based on the determinant of the transfer function matrix of the introduced...

  9. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  10. Primary ventriculoperitoneal shunting outcomes: a multicentre clinical audit for shunt infection and its risk factors.

    Science.gov (United States)

    Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S

    2016-10-01

    To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong

  11. Infant-mortality testing of high-energy-density capacitors used on Nova

    International Nuclear Information System (INIS)

    Merritt, B.T.; Whitham, K.

    1983-01-01

    Nova is a solid-state large laser for inertial-confinement fusion research. Its flashlamps are driven by a 60-MJ capacitor bank. Part of this bank is being built with high-energy-density capacitors, 52-μF, 22 kV, 12.5 kJ. A total of 2645 of these capacitors have been purchased from two manufacturers. Each capacitor was infant-mortality tested. The first test consisted of a high-potential test, bushing-to-case, since these capacitors have dual bushings. Then the capacitors were discharged 500 times with circuit conditions approximating the capacitors normal flashlamp load. Failure of either of these tests or if the capacitor was leaking was cause for rejection

  12. Neural networks for combined control of capacitor banks and voltage regulators in distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Z.; Rizy, D.T.

    1996-02-01

    A neural network for controlling shunt capacitor banks and feeder voltage regulators in electric distribution systems is presented. The objective of the neural controller is to minimize total I{sup 2}R losses and maintain all bus voltages within standard limits. The performance of the neural network for different input selections and training data is discussed and compared. Two different input selections are tried, one using the previous control states of the capacitors and regulator along with measured line flows and voltage which is equivalent to having feedback and the other with measured line flows and voltage without previous control settings. The results indicate that the neural net controller with feedback can outperform the one without. Also, proper selection of a training data set that adequately covers the operating space of the distribution system is important for achieving satisfactory performance with the neural controller. The neural controller is tested on a radially configured distribution system with 30 buses, 5 switchable capacitor banks an d one nine tap line regulator to demonstrate the performance characteristics associated with these principles. Monte Carlo simulations show that a carefully designed and relatively compact neural network with a small but carefully developed training set can perform quite well under slight and extreme variation of loading conditions.

  13. Ventriculoperitoneal shunt complications needing shunt revision in children: A review of 5 years of experience with 48 revisions

    Directory of Open Access Journals (Sweden)

    Rajendra K Ghritlaharey

    2012-01-01

    Full Text Available Background: The aim of this study was to review the management of ventriculoperitoneal (VP shunt complications in children. Patients and Methods: During the last 5 years (January 1, 2006 to December 31, 2010, 236 VP shunt operations were performed in children under 12 years of age; of these, 40 (16.94% developed shunt complications and those who underwent VP shunt revisions were studied. Results: This prospective study included 40 (28 boys and 12 girls children and required 48 shunt revisions. Complications following VP shunts that required shunt revisions were peritoneal catheter/peritoneal end malfunction (18, shunt/shunt tract infections (7, extrusion of peritoneal catheter through anus (5, ventricular catheter malfunction (4, cerebrospinal fluid (CSF leak from abdominal wound (4, shunt system failure (2, ventricular end/shunt displacement (2, CSF pseudocysts peritoneal cavity (2, extrusion of peritoneal catheter from neck, chest, abdominal scar and through umbilicus, one each. Four-fifth of these shunt complications occurred within 6 months of previous surgery. Surgical procedures done during shunt revisions in order of frequency were revision of peritoneal part of shunt (27, 56.25%, revision of entire shunt system (6, 12.5%, extra ventricular drainage and delayed re-shunt (5, 10.41%, shunt removal and delayed re-shunt (5, 10.41%, opposite side shunting (2, 4.16%, cysts excision and revision of peritoneal catheter (2, 4.16% and revision of ventricular catheter (1, 2.08%. The mortalities following VP shunt operations were 44 (18.64% and following shunt revisions were 4 (10%. Conclusions: VP shunt done for hydrocephalus in children is not only prone for complications and need for revision surgery but also associated with considerable mortality.

  14. Shunt impedance of spiral loaded resonant rf cavities

    International Nuclear Information System (INIS)

    Peebles, P.Z. Jr.; Parvarandeh, M.

    1975-01-01

    Based upon a treatment of the spiral loaded resonant radio frequency cavity as a shorted quarter-wave transmission line, a model for shunt impedance is developed. The model is applicable to loosely wound spirals in large diameter containers. Theoretical shunt impedance is given for spirals wound from tubing of circular or rectangular cross section. The former produces higher shunt impedance. Measurements made at Oak Ridge National Laboratory on 17 copper cavities are described which support the theoretical results. Theoretical results are also compared to data from twenty-three additional cavities measured at Los Alamos Scientific Laboratory. It is shown that the theoretical function forms a useful means of interpreting the quality of constructed cavities. (author)

  15. Atomic Layer Deposition Alumina-Passivated Silicon Nanowires: Probing the Transition from Electrochemical Double-Layer Capacitor to Electrolytic Capacitor.

    Science.gov (United States)

    Gaboriau, Dorian; Boniface, Maxime; Valero, Anthony; Aldakov, Dmitry; Brousse, Thierry; Gentile, Pascal; Sadki, Said

    2017-04-19

    Silicon nanowires were coated by a 1-5 nm thin alumina layer by atomic layer deposition (ALD) in order to replace poorly reproducible and unstable native silicon oxide by a highly conformal passivating alumina layer. The surface coating enabled probing the behavior of symmetric devices using such electrodes in the EMI-TFSI electrolyte, allowing us to attain a large cell voltage up to 6 V in ionic liquid, together with very high cyclability with less than 4% capacitance fade after 10 6 charge/discharge cycles. These results yielded fruitful insights into the transition between an electrochemical double-layer capacitor behavior and an electrolytic capacitor behavior. Ultimately, thin ALD dielectric coatings can be used to obtain hybrid devices exhibiting large cell voltage and excellent cycle life of dielectric capacitors, while retaining energy and power densities close to the ones displayed by supercapacitors.

  16. Split-phase motor running as capacitor starts motor and as capacitor run motor

    Directory of Open Access Journals (Sweden)

    Yahaya Asizehi ENESI

    2016-07-01

    Full Text Available In this paper, the input parameters of a single phase split-phase induction motor is taken to investigate and to study the output performance characteristics of capacitor start and capacitor run induction motor. The value of these input parameters are used in the design characteristics of capacitor run and capacitor start motor with each motor connected to rated or standard capacitor in series with auxiliary winding or starting winding respectively for the normal operational condition. The magnitude of capacitor that will develop maximum torque in capacitor start motor and capacitor run motor are investigated and determined by simulation. Each of these capacitors is connected to the auxiliary winding of split-phase motor thereby transforming it into capacitor start or capacitor run motor. The starting current and starting torque of the split-phase motor (SPM, capacitor run motor (CRM and capacitor star motor (CSM are compared for their suitability in their operational performance and applications.

  17. Successful Embolization of a Spontaneous Mesocaval Shunt Using the Amplatzer Vascular Plug II

    International Nuclear Information System (INIS)

    Boixadera, Helena; Tomasello, Alejandro; Quiroga, Sergi; Cordoba, Joan; Perez, Mercedes; Segarra, Antoni

    2010-01-01

    A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involving the superior mesenteric vein.

  18. Simulation study and experimental results for detection and classification of the transient capacitor inrush current using discrete wavelet transform and artificial intelligence

    Directory of Open Access Journals (Sweden)

    Patcharoen Theerasak

    2018-04-01

    Full Text Available This paper describes the combination of discrete wavelet transforms (DWT and artificial intelligence (AI, which are efficient techniques to identify the type of inrush current, analyze the origin and possible cause on the capacitor bank switching. The experiment setup used to verify the proposed techniques can be detected and classified the transient inrush current from normal capacitor rated current. The discrete wavelet transforms are used to detect and classify the inrush current. Then, output from wavelet is acted as input of fuzzy inference system for discriminating the type of switching transient inrush current. The proposed technique shows enhanced performance with a discrimination accuracy of 90.57%. Both simulation study and experimental results are quite satisfactory with providing the high accuracy and reliability which can be developed and implemented into a numerical overcurrent (50/51 and unbalanced current (60C protection relay for an application of shunt capacitor bank protection in the future.

  19. Simulation study and experimental results for detection and classification of the transient capacitor inrush current using discrete wavelet transform and artificial intelligence

    Science.gov (United States)

    Patcharoen, Theerasak; Yoomak, Suntiti; Ngaopitakkul, Atthapol; Pothisarn, Chaichan

    2018-04-01

    This paper describes the combination of discrete wavelet transforms (DWT) and artificial intelligence (AI), which are efficient techniques to identify the type of inrush current, analyze the origin and possible cause on the capacitor bank switching. The experiment setup used to verify the proposed techniques can be detected and classified the transient inrush current from normal capacitor rated current. The discrete wavelet transforms are used to detect and classify the inrush current. Then, output from wavelet is acted as input of fuzzy inference system for discriminating the type of switching transient inrush current. The proposed technique shows enhanced performance with a discrimination accuracy of 90.57%. Both simulation study and experimental results are quite satisfactory with providing the high accuracy and reliability which can be developed and implemented into a numerical overcurrent (50/51) and unbalanced current (60C) protection relay for an application of shunt capacitor bank protection in the future.

  20. Ventriculoperitoneal shunt blockage by hydatid cyst

    Directory of Open Access Journals (Sweden)

    Abrar A Wani

    2013-01-01

    Full Text Available Ventriculoperitoneal (VP shunt is one of the commonest procedures done in neurosurgical practice throughout the world. One of the commonest problems after putting the VP shunt is the shunt obstruction, which can be due to varied causes. Shunt obstruction secondary to the parasitic infections is rarely seen. We are presenting a 15-year-old child, a case of operated cerebral hydatid cyst with hydrocephalus. She presented with shunt malfunction after 1 year of surgical excision of the hydatid cyst. Revision of the VP shunt was done and peroperatively, it was found that the shunt tubing was obstructed due to small hydatid cysts. This is the first reported case of VP shunt obstruction by hydatid cyst.

  1. Capacitor current feedback for output filter damping in switched-mode magnet power supplies

    International Nuclear Information System (INIS)

    Paven Kumar, M.R.; Kim, J.M.S.

    1994-01-01

    In magnet power supplies for a particle accelerator system, a second-order low-pass filter is used to reduce the output current ripple content within specifications. The output filter must be properly damped in order to avoid any large amplification at the resonant frequency and large transient responses of voltages and currents at the step change of the line voltage. Conventionally, a series combination of resistance and capacitance is added in parallel with the filter capacitor to provide the required damping. This approach, however, requires a large dc-blocking capacitor which has to be several times larger than the filter capacitor. In this paper, a filter damping technique using capacitor current feedback is presented. The basic concept of the capacitor current feedback is established using a linear model of the converter involved, and then a sampled-data model of the converter is used to analyze the filter damping technique. The filter damping effect of the capacitor current feedback is verified experimentally

  2. Low-dimensional carbon and MXene-based electrochemical capacitor electrodes.

    Science.gov (United States)

    Yoon, Yeoheung; Lee, Keunsik; Lee, Hyoyoung

    2016-04-29

    Due to their unique structure and outstanding intrinsic physical properties such as extraordinarily high electrical conductivity, large surface area, and various chemical functionalities, low-dimension-based materials exhibit great potential for application in electrochemical capacitors (ECs). The electrical properties of electrochemical capacitors are determined by the electrode materials. Because energy charge storage is a surface process, the surface properties of the electrode materials greatly influence the electrochemical performance of the cell. Recently, graphene, a single layer of sp(2)-bonded carbon atoms arrayed into two-dimensional carbon nanomaterial, has attracted wide interest as an electrode material for electrochemical capacitor applications due to its unique properties, including a high electrical conductivity and large surface area. Several low-dimensional materials with large surface areas and high conductivity such as onion-like carbons (OLCs), carbide-derived carbons (CDCs), carbon nanotubes (CNTs), graphene, metal hydroxide, transition metal dichalcogenides (TMDs), and most recently MXene, have been developed for electrochemical capacitors. Therefore, it is useful to understand the current issues of low-dimensional materials and their device applications.

  3. Low-dimensional carbon and MXene-based electrochemical capacitor electrodes

    International Nuclear Information System (INIS)

    Yoon, Yeoheung; Lee, Hyoyoung; Lee, Keunsik

    2016-01-01

    Due to their unique structure and outstanding intrinsic physical properties such as extraordinarily high electrical conductivity, large surface area, and various chemical functionalities, low-dimension-based materials exhibit great potential for application in electrochemical capacitors (ECs). The electrical properties of electrochemical capacitors are determined by the electrode materials. Because energy charge storage is a surface process, the surface properties of the electrode materials greatly influence the electrochemical performance of the cell. Recently, graphene, a single layer of sp 2 -bonded carbon atoms arrayed into two-dimensional carbon nanomaterial, has attracted wide interest as an electrode material for electrochemical capacitor applications due to its unique properties, including a high electrical conductivity and large surface area. Several low-dimensional materials with large surface areas and high conductivity such as onion-like carbons (OLCs), carbide-derived carbons (CDCs), carbon nanotubes (CNTs), graphene, metal hydroxide, transition metal dichalcogenides (TMDs), and most recently MXene, have been developed for electrochemical capacitors. Therefore, it is useful to understand the current issues of low-dimensional materials and their device applications. (topical review)

  4. Structural integrity of ceramic multilayer capacitor materials and ceramic multilayer capacitors

    NARCIS (Netherlands)

    With, de G.

    1993-01-01

    An review with 61 refs. is given of the fracture of and stress situation in ceramic capacitor materials and ceramic multilayer capacitors. A brief introduction to the relevant concepts is given first. Next the data for capacitor materials and the data for capacitors are discussed. The materials data

  5. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Science.gov (United States)

    Van den Bossche, Lindsay; Schoonenberg, Vivien A C; Burgener, Iwan A; Penning, Louis C; Schrall, Ingrid M; Kruitwagen, Hedwig S; van Wolferen, Monique E; Grinwis, Guy C M; Kummeling, Anne; Rothuizen, Jan; van Velzen, Jeroen F; Stathonikos, Nikolas; Molenaar, Martijn R; Helms, Bernd J; Brouwers, Jos F H M; Spee, Bart; van Steenbeek, Frank G

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS) and intrahepatic portosystemic shunts (IHPSS) was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS Plipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  6. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G; Misaka, Isamu; Watanabe, Edson H [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  7. Congenital Intrahepatic Portosystemic Shunts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Young Tong; Jou, Sung Shick; Shin, Hyeong Cheol [Soonchunhyang University, Asan (Korea, Republic of)

    2008-12-15

    Intrahepatic portosystemic shunts are an anomalous connection between the portal vein and hepatic vein/IVC, which may be either congenital or acquired secondary to liver cirrhosis or portal hypertension. Cases of congenital intrahepatic shunts are usually encountered in children and may spontaneously resolve. We report 5 cases of congenital intrahepatic portosystemic shunts in neonates and an adult

  8. Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?

    Science.gov (United States)

    Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos

    2016-08-01

    Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Infant mortality testing of high energy-density capacitors used on Nova

    International Nuclear Information System (INIS)

    Merritt, B.T.; Whitham, K.

    1983-01-01

    Nova is a solid state large laser for inertial confinement fusion research. Its flashlamps are driven by a 60 MJ capacitor bank. Part of this bank is being built with high energy-density capacitors, 52 μF, 22 KV, 12.5 KJ. A total of 2,645 of these capacitors have been purchased from two manufacturers. Each capacitor was infant mortality tested. The first test consisted of a high-potential test, bushing-to-case, since these capacitors have dual bushings. Then the capacitors were discharged 500 times with circuit conditions approximating the capacitors normal flashlamp load. Failure of either of these tests or if the capacitor was leaking was cause for rejection. The test results were remarkably good. Less than 0.5 percent failed the pulse-discharge test and less than 2.5 percent were rejected overall

  10. Rate of shunt revision as a function of age in patients with shunted hydrocephalus due to myelomeningocele.

    Science.gov (United States)

    Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G

    2016-11-01

    OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and

  11. Does a meso-caval shunt have positive effects in a pig large-for-size liver transplantation model?

    Science.gov (United States)

    Tannuri, Ana Cristina Aoun; de Albuquerque Rangel Moreira, Daniel; Belon, Alessandro; Coelho, Maria Cecília Mendonça; Gonçalves, Josiane Oliveira; Serafini, Suellen; Tannuri, Uenis

    2017-08-01

    In pediatric liver transplantations with LFS grafts, higher incidences of graft dysfunction probably occur due to IRI. It was postulated that increasing the blood supply to the graft by means of a meso-caval shunt could ameliorate the IRI. Eleven pigs underwent liver transplantation and were divided into two groups: LFS and LFS+SHUNT group. A series of flowmetric, metabolic, histologic, and molecular studies were performed. No significant metabolic differences were observed between the groups. One hour after reperfusion, portal flow was significantly lower in the recipients than in the donors, proving that the graft was maintained in low portal blood flow, although the shunt could promote a transient increase in the portal blood flow and a decrease in the arterial flow. Finally, it was verified that the shunt promoted a decrease in inflammation and steatosis scores and a decrease in the expression of the eNOS gene (responsible for the generation of nitric oxide in the vascular endothelium) and an increase in the expression of the proapoptotic gene BAX. The meso-caval shunt was responsible for some positive effects, although other deleterious flowmetric and molecular alterations also occurred. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Evaluation of Case Size 0603 BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2015-01-01

    High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

  13. Graphene-Based Flexible and Transparent Tunable Capacitors.

    Science.gov (United States)

    Man, Baoyuan; Xu, Shicai; Jiang, Shouzheng; Liu, Aihua; Gao, Shoubao; Zhang, Chao; Qiu, Hengwei; Li, Zhen

    2015-12-01

    We report a kind of electric field tunable transparent and flexible capacitor with the structure of graphene-Bi1.5MgNb1.5O7 (BMN)-graphene. The graphene films with low sheet resistance were grown by chemical vapor deposition. The BMN thin films were fabricated on graphene by using laser molecular beam epitaxy technology. Compared to BMN films grown on Au, the samples on graphene substrates show better quality in terms of crystallinity, surface morphology, leakage current, and loss tangent. By transferring another graphene layer, we fabricated flexible and transparent capacitors with the structure of graphene-BMN-graphene. The capacitors show a large dielectric constant of 113 with high dielectric tunability of ~40.7 % at a bias field of 1.0 MV/cm. Also, the capacitor can work stably in the high bending condition with curvature radii as low as 10 mm. This flexible film capacitor has a high optical transparency of ~90 % in the visible light region, demonstrating their potential application for a wide range of flexible electronic devices.

  14. A New Optimization Framework To Solve The Optimal Feeder Reconfiguration And Capacitor Placement Problems

    Directory of Open Access Journals (Sweden)

    Mohammad-Reza Askari

    2015-07-01

    Full Text Available Abstract This paper introduces a new stochastic optimization framework based bat algorithm BA to solve the optimal distribution feeder reconfiguration DFR as well as the shunt capacitor placement and sizing in the distribution systems. The objective functions to be investigated are minimization of the active power losses and minimization of the total network costs an. In order to consider the uncertainties of the active and reactive loads in the problem point estimate method PEM with 2m scheme is employed as the stochastic tool. The feasibility and good performance of the proposed method are examined on the IEEE 69-bus test system.

  15. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  16. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Directory of Open Access Journals (Sweden)

    Lindsay Van den Bossche

    Full Text Available Non-alcoholic fatty liver disease (NAFLD is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS and intrahepatic portosystemic shunts (IHPSS was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS P<0.01; IHPSS P = 0.042. Involvement of lipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  17. Transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Han, Man Chung [Seoul National University College of Medicidne, Seoul (Korea, Republic of)

    1992-05-15

    As a new interventional procedure for the control of variceal bleeding, a portosystemic shunt can be established with the installment of metallic stent through the transjugular approach. In order to evaluate the clinical usefulness of the procedure, transjugular intrahepatic portosystemic shunt procedure were performed in 5 patients with variceal bleeding due to liver cirrhosis. The metallic stents were mainly a self expandable Wallstent (Schneider, Switzerland), An 8 to 10 mm shunt was formed by the insertion of the stent and balloon dilatation after puncture of the proximal portal vein from the right or middle hepatic vein. The patency of the shunt was proven by portography after the procedure. The portal pressure measured in 3 patients before and after the procedure improved with decrease from 31 mmHg to 25 mmHg. The procedure failed in 1 patient due to pre-existing portal vein thrombosis. During the follow-up period from 1 month to 4 months, shunts were patent in all 4 patients. However, hepatic encephalopathy occurred in one patient one week following the procedure. Though the follow-up period was not long enough for full evaluation, we found the transjugular intrahepatic portosystemic shunt was a safe and effective procedure for the control of variceal bleeding by lowering the portal pressure. For the appropriate application for this procedure, the optimal size of the shunt and optical degree of the resultant decompression are yet to be determined in the future.

  18. A Novel Analytical Technique for Optimal Allocation of Capacitors in Radial Distribution Systems

    Directory of Open Access Journals (Sweden)

    Sarfaraz Nawaz

    2017-07-01

    Full Text Available In this paper, a novel analytical technique is proposed to determine the optimal size and location of shunt capacitor units in radial distribution systems. An objective function is formulated to reduce real power loss, to improve the voltage profile and to increase annual cost savings. A new constant, the Loss Sensitivity Constant (LSC, is proposed here. The value of LSC decides the location and size of candidate buses. The technique is demonstrated on an IEEE-33 bus system at different load levels and the 130-bus distribution system of Jamawa Ramgarh village, Jaipur city. The obtained results are compared with the latest optimization techniques to show the effectiveness and robustness of the proposed technique.

  19. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  20. Pathological Predictors of Shunt Stenosis and Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt

    Directory of Open Access Journals (Sweden)

    Fuliang He

    2016-01-01

    Full Text Available Background. Transjugular intrahepatic portosystemic shunt (TIPS is an artificial channel from the portal vein to the hepatic vein or vena cava for controlling portal vein hypertension. The major drawbacks of TIPS are shunt stenosis and hepatic encephalopathy (HE; previous studies showed that post-TIPS shunt stenosis and HE might be correlated with the pathological features of the liver tissues. Therefore, we analyzed the pathological predictors for clinical outcome, to determine the risk factors for shunt stenosis and HE after TIPS. Methods. We recruited 361 patients who suffered from portal hypertension symptoms and were treated with TIPS from January 2009 to December 2012. Results. Multivariate logistic regression analysis showed that the risk of shunt stenosis was increased with more severe inflammation in the liver tissue (OR, 2.864; 95% CI: 1.466–5.592; P=0.002, HE comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, or higher MELD score (95% CI, 1.298–1.731; P<0.001. Higher risk of HE was associated with shunt stenosis comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, higher stage of the liver fibrosis (OR, 2.431; 95% CI, 1.355–4.359; P=0.003, and higher MELD score (95% CI, 1.711–2.406; P<0.001. Conclusion. The pathological features can predict individual susceptibility to shunt stenosis and HE.

  1. 30 CFR 56.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Explosives Electric Blasting § 56.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be kept shunted until...

  2. Charging large capacitor banks for fusion research using HVDC conversion equipment

    International Nuclear Information System (INIS)

    Brown, D.R.; Bird, W.L.; Huang, Y.C.; Tolk, K.

    1984-01-01

    Fundamental considerations in the choice of a continuous duty capacitor bank charging system using HVDC conversion equipment are presented. Large systems of the type used in fusion related research pose significant system related problems if they are to be supplied from a conventional power grid. Schemes for conditioning the required power in order to overcome such problems are presented and evaluated. A resonant charging system is examined in detail and shown to be superior in a number of ways to constant current charging. Results of digital computer simulation studies are used to demonstrate the feasibility of the system. It is shown that the resonant charging system reduces rectifier capacity, simplifies control and reduces reactive power fluctuations. Sequential bank charging and use of a motor-generator set are presented as techniques for compensation of real power fluctuations and a comparison on the basis of initial cost is presented

  3. Capacitor voltage ripple reduction and arm energy balancing in MMC-HVDC

    DEFF Research Database (Denmark)

    Parikh, Harsh; Martin-Loeches, Ruben Sánches; Tsolaridis, Georgios

    2016-01-01

    Modular Multilevel Converters are emerging and widely used in HVDC applications. However, the submodule capacitors are still large and the energy balancing under unbalanced conditions is a challenge. In this paper, an analytical model focusing on the energy stored in the capacitors and voltage...... variations is utilized in order to achieve better performance. By injecting a second order harmonic component into the circulating current, the energy variation and consequently the capacitor voltage ripple is reduced allowing for a capacitor size reduction. At the same time, an arm energy balancing...

  4. Intrahepatic Portosystemic Venous Shunt: Successful Embolization Using the Amplatzer Vascular Plug II

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Ju; Shin, Byung Seok; Lee, In Ho; Ohm, Joon Young; Lee, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2012-11-15

    A 67-year-old woman presented with memory impairment and behavioral changes. Brain MRI indicated hepatic encephalopathy. Abdominal CT scans revealed an intrahepatic portosystemic venous shunt that consisted of two shunt tracts to the aneurysmal sac that communicated directly with the right hepatic vein. The large tract was successfully occluded by embolization using the newly available AMPLATZERTM Vascular Plug II and the small tract was occluded by using coils. The patient's symptoms disappeared after shunt closure and she remained free of recurrence at the 3-month follow-up evaluation.

  5. Portal hypertension: A critical appraisal of shunt procedures with emphasis on distal splenorenal shunt in children

    Directory of Open Access Journals (Sweden)

    Nitin Sharma

    2014-01-01

    Full Text Available Background: Extrahepatic portal venous obstruction (EHPVO is the most common cause of pediatric portal hypertension. We analyzed the investigative protocol and results of portosystemic shunts in this group of patients. Materials and Methods: A total of 40 consecutive children aged below 12 years operated with a diagnosis of extra-hepatic portal hypertension formed the study group. Historical data and clinical data were collected. All patients underwent upper gastrointestinal endoscopy, ultrasound Doppler and computed tomographic portogram pre-operatively and post-operatively. Results with respect to shunt patency, hypersplenism and efficacy of different radiological investigations were collected. Results: A total of 40 patients, 28 boys and 12 girls constituted the study group. Lienorenal shunt (LRS was performed in 14 patients; distal splenorenal shunt in 21 patients and side-to-side lienorenal shunt in 4 patients, inferior mesenteric renal shunt was performed in 1 patient. Follow-up ranged from 36 to 70 months. At a minimum follow-up of 3 years, 32 (80% patients were found to have patent shunts. Patent shunts could be visualized in 30/32 patients with computer tomographic portogram (CTP and 28/32 with ultrasound. Varices regressed completely in 26/32 patients and in the rest incomplete regression was seen. Spleen completely regressed in 19/25 patients. Hypersplenism resolved in all patients with patent shunts. Conclusions: Portosystemic shunting in children with EHPVO is a viable option. While long-term cure rates are comparable with sclerotherapy, repeated hospital visits are reduced with one time surgery. Pre-operative and post-operative assessment can be performed with complimentary use of ultrasound, CTP and endoscopy.

  6. Split-phase motor running as capacitor starts motor and as capacitor run motor

    OpenAIRE

    Yahaya Asizehi ENESI; Jacob TSADO; Mark NWOHU; Usman Abraham USMAN; Odu Ayo IMORU

    2016-01-01

    In this paper, the input parameters of a single phase split-phase induction motor is taken to investigate and to study the output performance characteristics of capacitor start and capacitor run induction motor. The value of these input parameters are used in the design characteristics of capacitor run and capacitor start motor with each motor connected to rated or standard capacitor in series with auxiliary winding or starting winding respectively for the normal operational condition. The ma...

  7. Congenital extrahepatic portosystemic shunt associated with heterotaxy and polysplenia

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley [Lucile Packard Children' s Hospital, Department of Radiology, Stanford University School of Medicine, Stanford, CA (United States); Feinstein, Jeffrey A. [Stanford University School of Medicine, Division of Pediatric Cardiology, Department of Pediatrics, Lucile Packard Children' s Hospital, Stanford (United States); Cohen, Ronald A.; Patel, Hitendra [Children' s Hospital and Research Center, Department of Diagnostic Radiology, Oakland, CA (United States); Feingold, Brian; Kreutzer, Jacqueline [Children' s Hospital of Pittsburgh, Department of Pediatrics, Division of Pediatric Cardiology, Pittsburgh, PA (United States); Chan, Fandics P. [Stanford University School of Medicine, Cardiovascular Imaging Section, Department of Radiology, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2010-07-15

    Heterotaxy with polysplenia is associated with many cardiovascular anomalies including the occasional occurrence of congenital extrahepatic portosystemic shunts (CEPS). Missing this anomaly can lead to inappropriate and ineffective therapy. To emphasize the importance and associated anatomy of CEPS in conjunction with heterotaxy with polysplenia. Review of three young children who presented with cyanosis and pulmonary hypertension without a cardiac etiology. They were known (1) or discovered (2) to have heterotaxy with polysplenia. There was absence of the intrahepatic inferior vena cava (IVC) with azygos or hemiazygos continuation in all three cases. In spite of normal liver function, they were discovered to have large portosystemic shunts, splenorenal in location, along with diffuse peripheral pulmonary arterial dilatation suggestive of CEPS (Abernethy malformation) with hepatopulmonary or, more accurately, portopulmonary syndrome. All CEPS were ipsilateral to the spleens. Patency of the portal veins in these cases allowed for percutaneous shunt closure with resolution of cyanosis. CEPS is associated with heterotaxy with polysplenia and can be symptomatic because of pulmonary arteriovenous (AV) shunting. Portal and hepatic vein patency are critical for determining feasibility of CEPS closure. (orig.)

  8. Over-drainage and persistent shunt-dependency in patients with idiopathic intracranial hypertension treated with shunts and bariatric surgery.

    Science.gov (United States)

    Roth, Jonathan; Constantini, Shlomi; Kesler, Anat

    2015-01-01

    Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.

  9. Dielectric capacitors with three-dimensional nanoscale interdigital electrodes for energy storage.

    Science.gov (United States)

    Han, Fangming; Meng, Guowen; Zhou, Fei; Song, Li; Li, Xinhua; Hu, Xiaoye; Zhu, Xiaoguang; Wu, Bing; Wei, Bingqing

    2015-10-01

    Dielectric capacitors are promising candidates for high-performance energy storage systems due to their high power density and increasing energy density. However, the traditional approach strategies to enhance the performance of dielectric capacitors cannot simultaneously achieve large capacitance and high breakdown voltage. We demonstrate that such limitations can be overcome by using a completely new three-dimensional (3D) nanoarchitectural electrode design. First, we fabricate a unique nanoporous anodic aluminum oxide (AAO) membrane with two sets of interdigitated and isolated straight nanopores opening toward opposite planar surfaces. By depositing carbon nanotubes in both sets of pores inside the AAO membrane, the new dielectric capacitor with 3D nanoscale interdigital electrodes is simply realized. In our new capacitors, the large specific surface area of AAO can provide large capacitance, whereas uniform pore walls and hemispheric barrier layers can enhance breakdown voltage. As a result, a high energy density of 2 Wh/kg, which is close to the value of a supercapacitor, can be achieved, showing promising potential in high-density electrical energy storage for various applications.

  10. Capacitance-voltage characterization of fully silicided gated MOS capacitor

    International Nuclear Information System (INIS)

    Wang Baomin; Ru Guoping; Jiang Yulong; Qu Xinping; Li Bingzong; Liu Ran

    2009-01-01

    This paper investigates the capacitance-voltage (C-V) measurement on fully silicided (FUSI) gated metal-oxide-semiconductor (MOS) capacitors and the applicability of MOS capacitor models. When the oxide leakage current of an MOS capacitor is large, two-element parallel or series model cannot be used to obtain its real C-V characteristic. A three-element model simultaneously consisting of parallel conductance and series resistance or a four-element model with further consideration of a series inductance should be used. We employed the three-element and the four-element models with the help of two-frequency technique to measure the Ni FUSI gated MOS capacitors. The results indicate that the capacitance of the MOS capacitors extracted by the three-element model still shows some frequency dispersion, while that extracted by the four-element model is close to the real capacitance, showing little frequency dispersion. The obtained capacitance can be used to calculate the dielectric thickness with quantum effect correction by NCSU C-V program. We also investigated the influence of MOS capacitor's area on the measurement accuracy. The results indicate that the decrease of capacitor area can reduce the dissipation factor and improve the measurement accuracy. As a result, the frequency dispersion of the measured capacitance is significantly reduced, and real C-V characteristic can be obtained directly by the series model. In addition, this paper investigates the quasi-static C-V measurement and the photonic high-frequency C-V measurement on Ni FUSI metal gated MOS capacitor with a thin leaky oxide. The results indicate that the large tunneling current through the gate oxide significantly perturbs the accurate measurement of the displacement current, which is essential for the quasi-static C-V measurement. On the other hand, the photonic high-frequency C-V measurement can bypass the leakage problem, and get reliable low-frequency C-V characteristic, which can be used to

  11. Flux shunts for undulators

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Hassenzahl, W.V.

    1993-05-01

    Undulators for high-performance applications in synchrotron-radiation sources and periodic magnetic structures for free-electron lasers have stringent requirements on the curvature of the electron's average trajectory. Undulators using the permanent magnet hybrid configuration often have fields in their central region that produce a curved trajectory caused by local, ambient magnetic fields such as those of the earth. The 4.6 m long Advanced Light Source (ALS) undulators use flux shunts to reduce this effect. These flux shunts are magnetic linkages of very high permeability material connecting the two steel beams that support the magnetic structures. The shunts reduce the scalar potential difference between the supporting beams and carry substantial flux that would normally appear in the undulator gap. Magnetic design, mechanical configuration of the flux shunts and magnetic measurements of their effect on the ALS undulators are described

  12. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  13. Vented Capacitor

    Science.gov (United States)

    Brubaker, Michael Allen; Hosking, Terry Alan

    2006-04-11

    A technique of increasing the corona inception voltage (CIV), and thereby increasing the operating voltage, of film/foil capacitors is described. Intentional venting of the capacitor encapsulation improves the corona inception voltage by allowing internal voids to equilibrate with the ambient environment.

  14. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  15. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  16. Subgaleo-peritoneal shunt: An effective and safer alternative to lumboperitoneal shunt in the management of persistent or recurrent iatrogenic cranial pseudomeningoceles.

    Science.gov (United States)

    Kiran, Narayanam Anantha Sai; Thakar, Sumit; Mohan, Dilip; Aryan, Saritha; Rao, Arun Sadashiva; Hegde, Alangar S

    2013-01-01

    Subgaleo-peritoneal (SP) shunting for pseudomeningoceles (PMCs) is an effective and safer alternative as compared to the lumboperitoneal (LP) shunt. SP shunting was done in six patients (14-60 years) with persistent or recurrent PMCs using the cranial (ventricular part) and the distal parts of a Chhabra shunt connected by a rigid connector without any intervening chamber or valve. Two patients had undergone a prior LP shunt that had failed. One patient was unsuitable for a LP shunt placement. The PMC subsided completely in all the patients following the SP shunt. In one patient, the shunt got displaced and required repositioning. None of the patients developed symptoms of over-drainage or any other complication. All patients were asymptomatic at a mean follow-up of 15 months. These results suggest that SP shunting is a safe, simple, and effective alternative to the traditional LP shunt in the management of persistent or recurrent cranial PMCs.

  17. A measurement technique of time-dependent dielectric breakdown in MOS capacitors

    Science.gov (United States)

    Li, S. P.

    1974-01-01

    The statistical nature of time-dependent dielectric breakdown characteristics in MOS capacitors was evidenced by testing large numbers of capacitors fabricated on single wafers. A multipoint probe and automatic electronic visual display technique are introduced that will yield statistical results which are necessary for the investigation of temperature, electric field, thermal annealing, and radiation effects in the breakdown characteristics, and an interpretation of the physical mechanisms involved. It is shown that capacitors of area greater than 0.002 sq cm may yield worst-case results, and that a multipoint probe of capacitors of smaller sizes can be used to obtain a profile of nonuniformities in the SiO2 films.

  18. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.-D.

    1996-05-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole, and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors, and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model

  19. Model for Calculating Electrolytic Shunt Path Losses in Large Electrochemical Energy Conversion Systems

    Science.gov (United States)

    Prokopius, P. R.

    1976-01-01

    Generalized analysis and solution techniques were developed to evaluate the shunt power losses in electrochemical systems designed with a common or circulating electrolyte supply. Sample data are presented for a hypothetical bulk energy storage redox system, and the general applicability of the analysis technique is discussed.

  20. Pediatric ventriculoperitoneal shunts and their complications: An analysis

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal

    2017-01-01

    Conclusion: With this retrospective review of complications of VP shunts, age at initial shunt insertion and the interval between the age of initial shunt placement and onset of complications were the most important patient-related predictors of shunt failure. The different predominant etiological factors responsible for early and late shunt failure were infective and mechanical complications, respectively.

  1. Pictorial essay: trans-jugular intra-hepatic porto-systemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Rao Anuradha, T.N.; Rastogi, H.; Pandey, U.C.

    2001-01-01

    TIPS is an interventional radiologic method of creating a portosystemic shunt by percutaneous means. It is a relatively new weapon in the armamentarium of the management of portal hypertension with variceal bleeding or intractable ascites. Using needles, angioplasty balloon catheters and expandable metallic stents, a shunt is established directly inside the liver parenchyma connecting a large hepatic vein with a main portal vein branch. Depending on the diameter of the expandable stent used, the created TIPS diverts various amounts of portal blood into the systemic circulation and results in significant portal decompression, cessation of hemorrhage from esophageal varices and resolution of ascites. TIPS is not only an effective and safe alternative to shunt surgery but is life saving in cases of variceal hemorrhage. The use of TIPS seems to be a valid alternative to surgery and has several advantages over either esophageal transection or surgical shunts. TIPS avoids a general anesthetic, laparotomy, and disruption of the hepatic venous system that may adversely affect subsequent hepatic transplantation. TIPS has been performed on patients without interfering with successful transplantation

  2. Superconducting fault current-limiter with variable shunt impedance

    Science.gov (United States)

    Llambes, Juan Carlos H; Xiong, Xuming

    2013-11-19

    A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

  3. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2011-02-01

    Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts.

  4. Capacitor assembly and related method of forming

    Science.gov (United States)

    Zhang, Lili; Tan, Daniel Qi; Sullivan, Jeffrey S.

    2017-12-19

    A capacitor assembly is disclosed. The capacitor assembly includes a housing. The capacitor assembly further includes a plurality of capacitors disposed within the housing. Furthermore, the capacitor assembly includes a thermally conductive article disposed about at least a portion of a capacitor body of the capacitors, and in thermal contact with the capacitor body. Moreover, the capacitor assembly also includes a heat sink disposed within the housing and in thermal contact with at least a portion of the housing and the thermally conductive article such that the heat sink is configured to remove heat from the capacitor in a radial direction of the capacitor assembly. Further, a method of forming the capacitor assembly is also presented.

  5. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.

    1997-01-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model. copyright 1997 American Institute of Physics

  6. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  7. Early mediastinal seroma secondary to modified Blalock-Taussig shunts - successful management by percutaneous drainage

    International Nuclear Information System (INIS)

    Connolly, Bairbre L.; Temple, Michael J.; Chait, Peter G.; Restrepo, Ricardo; Adatia, Ian

    2003-01-01

    Large symptomatic mediastinal seroma following modified-BT shunts, traditionally required revisional thoracotomy. We describe percutaneous image-guided pigtail catheter drainage in the successful treatment of early mediastinal seroma secondary to PTFE Blalock-Taussig shunt, avoiding thoracotomy. A retrospective review of all relevant clinical and imaging records in five patients was performed. All five presented with intermittent stridor, respiratory distress and/or episodic desaturation within 6 weeks of their surgery. In four of five infants, percutaneous drainage was effective and reoperation was avoided. In one of five, rather than urgent surgical evacuation and BT shunt revision, we were able to perform an elective stage-II bidirectional Glenn SVC-RA anastamosis in a stable infant. There were no complications. Percutaneous image-guided drainage of mediastinal seroma secondary to PTFE-BT shunt is a safe, minimally invasive, and effective treatment. This may avoid BT shunt revision. (orig.)

  8. A new method for the measurement of intrahepatic shunts

    International Nuclear Information System (INIS)

    Hoefs, J.C.; Reynolds, T.B.; Pare, P.; Sakimura, I.

    1984-01-01

    After transhepatic portal pressure determination, 96 patients were assessed for the presence of intrahepatic shunts by injection of microspheres (25 +/- 5 micron diameter) into the portal vein using RISA-131I as an indicator of dilution. Multiple portal vein injections in each patient allowed blood sampling from the hepatic vein (site 1) and from two inferior vena cava sampling sites (site 2, at the junction of the hepatic vein orifice with the inferior vena cava, and site 3, 2 to 3 cm closer to or within the right atrium). Intrahepatic shunting was calculated from each site: hepatic vein in 57 patients and inferior vena cava, site 2 in 43 patients and site 3 in 77 patients. At least one valid IHS calculation was available in 92 of the patients. Intrahepatic shunting calculated from sequential portal vein injections with sampling from the hepatic vein was highly correlated (r . 0.98, p less than 0.0001, slope . 1.0), with a mean difference of 1.9% +/- 1.9%. There was no significant difference by t test comparison of the mean IHS calculated from sites 1, 2, and 3. Occasional marked discrepancies were noted between IHS calculated from site 1 or site 2 compared with site 3, and the site 3 calculation was always greater. A shunt index in all patients included shunts calculated from the hepatic vein in 57 patients plus shunt calculation from the inferior vena cava in the remaining patients (site 2 in 26 patients and site 3 in nine). The 82 patients with portal hypertension or chronic liver disease had a higher portal pressure, 13.8 +/- 4.6 mm Hg, and a significantly greater shunt index, 13.7% +/- 24.5% compared with controls. The frequency distribution of IHS in patients with chronic liver disease demonstrated less than 2% IHS in 49% of patients and less than 5% IHS in 63%. The validity of our methods and the implications of the infrequent demonstration of a large IHS are discussed

  9. Materials for electrochemical capacitors

    Science.gov (United States)

    Simon, Patrice; Gogotsi, Yury

    2008-11-01

    Electrochemical capacitors, also called supercapacitors, store energy using either ion adsorption (electrochemical double layer capacitors) or fast surface redox reactions (pseudo-capacitors). They can complement or replace batteries in electrical energy storage and harvesting applications, when high power delivery or uptake is needed. A notable improvement in performance has been achieved through recent advances in understanding charge storage mechanisms and the development of advanced nanostructured materials. The discovery that ion desolvation occurs in pores smaller than the solvated ions has led to higher capacitance for electrochemical double layer capacitors using carbon electrodes with subnanometre pores, and opened the door to designing high-energy density devices using a variety of electrolytes. Combination of pseudo-capacitive nanomaterials, including oxides, nitrides and polymers, with the latest generation of nanostructured lithium electrodes has brought the energy density of electrochemical capacitors closer to that of batteries. The use of carbon nanotubes has further advanced micro-electrochemical capacitors, enabling flexible and adaptable devices to be made. Mathematical modelling and simulation will be the key to success in designing tomorrow's high-energy and high-power devices.

  10. Capacitor discharge engineering

    CERN Document Server

    Früngel, Frank B A

    1976-01-01

    High Speed Pulse Technology, Volume III: Capacitor Discharge Engineering covers the production and practical application of capacitor dischargers for the generation and utilization of high speed pulsed of energy in different forms. This nine-chapter volume discusses the principles of electric current, voltage, X-rays, gamma rays, heat, beams of electrons, neutrons and ions, magnetic fields, sound, and shock waves in gases and liquids. Considerable chapters consider the applications of capacitor discharges, such as impulse hardening of steel, ultrapulse welding of precision parts, X-ray flash t

  11. Congenital portosystemic shunts with and without gastrointestinal bleeding - case series

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ying; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Qiao, Zhongwei [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Zhu, Hui [Fudan University Shanghai Cancer Center, Department of Radiology, Shanghai (China); Zheng, Shan [Children' s Hospital of Fudan University, Department of Surgery, Shanghai (China)

    2015-12-15

    The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high. (orig.)

  12. Outcomes of systemic to pulmonary artery shunts in patients weighing less than 3 kg: analysis of shunt type, size, and surgical approach.

    Science.gov (United States)

    Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K

    2014-02-01

    To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. Electric converters of electromagnetic strike machine with capacitor supply

    Science.gov (United States)

    Usanov, K. M.; Volgin, A. V.; Kargin, V. A.; Moiseev, A. P.; Chetverikov, E. A.

    2018-03-01

    The application of pulse linear electromagnetic engines in small power strike machines (energy impact is 0.01...1.0 kJ), where the characteristic mode of rare beats (pulse seismic vibrator, the arch crash device bins bulk materials), is quite effective. At the same time, the technical and economic performance of such machines is largely determined by the ability of the power source to provide a large instantaneous power of the supply pulses in the winding of the linear electromagnetic motor. The use of intermediate energy storage devices in power systems of rare-shock LEME makes it possible to obtain easily large instantaneous powers, forced energy conversion, and increase the performance of the machine. A capacitor power supply of a pulsed source of seismic waves is proposed for the exploration of shallow depths. The sections of the capacitor storage (CS) are connected to the winding of the linear electromagnetic motor by thyristor dischargers, the sequence of activation of which is determined by the control device. The charge of the capacitors to the required voltage is made directly from the battery source, or through the converter from a battery source with a smaller number of batteries.

  14. Phase shift PWM with double two-switch bridge for high power capacitor charging

    International Nuclear Information System (INIS)

    Karandikar, U.S.; Singh, Yashpal; Thakurta, A.C.

    2013-01-01

    Pulse power supply systems working at higher voltage and high repetition rate demands for higher power from capacitor chargers. Capacitor charging requirement become more challenging in such cases. In pulse power circuits, energy storage capacitor should be charged to its desired voltage before the next switching occurs. It is discharged within a small time, delivering large pulse power. A capacitor charger has to work with wide load variation repeatedly. Many schemes are used for this purpose. The proposed scheme aims at reducing stresses on switches by reducing peak current and their evils. A high voltage power supply is designed for capacitor charging. The proposed scheme is based on a Phase-Shifted PWM without using any extra component to achieve soft switching. Indirect constant average current capacitor charging is achieved with a simple control scheme. A double two-switch bridge is proposed to enhance reliability. Power supply has been developed to charge a capacitor of 50 μF to 2.5 kV at 25 Hz. (author)

  15. A Two-terminal Active Capacitor

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai

    2017-01-01

    This letter proposes a concept of two-terminal active capacitor implemented by power semiconductor switches and passive elements. The active capacitor has the same level of convenience as a passive one with two power terminals only. It is application independent and can be specified by rated...... voltage, ripple current, equivalent series resistance, and operational frequency range. The concept, control method, self-power scheme, and impedance characteristics of the active capacitor are presented. A case study of the proposed active capacitor for a capacitive DC-link application is discussed....... The results reveal a significantly lower overall energy storage of passive elements and a reduced cost to fulfill a specific reliability target, compared to a passive capacitor solution. Proof-of-concept experimental results are given to verify the functionality of the proposed capacitor....

  16. The desing study of high voltage plasma focus for a large fluence neutron source by using a water capacitor bank

    International Nuclear Information System (INIS)

    Ueno, Isao; Kobata, Tadasuke

    1983-01-01

    A new possibility for high intensity neutron source (HINS) would be opened by the plasma focus device if we have a high voltage capacitor bank. A scaling law of neutron yield for D-T gas discharge in plasma focus device is obtained after Imshennik, Filippov and Filippova. The resulting scaling law shows the realizability of the D-T HINS by the use of plasma focus, provided that the device is operated under a high voltage condition. Until now, it has been difficult to construct the high voltage capacitor bank of long life, for example with V 0 =300kV, C 0 =200μF and L 0 --5nH necessary in the level of HINS. It becomes possible to design this capacitor bank by using the coaxial water capacitor which has been developed for the electron and ion beam accelerator. The size of a capacitor designed for V 0 =300kV, C 0 =1μF is phi5m x 22m. Two hundred capacitors are used in parallel in order to get the 200μF. (author)

  17. Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.

    Science.gov (United States)

    Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil

    2005-01-01

    The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal

  18. Cell shunt resistance and photovoltaic module performance

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, T.J.; Basso, T.S.; Rummel, S.R. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    Shunt resistance of cells in photovoltaic modules can affect module power output and could indicate flawed manufacturing processes and reliability problems. The authors describe a two-terminal diagnostic method to directly measure the shunt resistance of individual cells in a series-connected module non-intrusively, without deencapsulation. Peak power efficiency vs. light intensity was measured on a 12-cell, series-connected, single crystalline module having relatively high cell shunt resistances. The module was remeasured with 0.5-, 1-, and 2-ohm resistors attached across each cell to simulate shunt resistances of several emerging technologies. Peak power efficiencies decreased dramatically at lower light levels. Using the PSpice circuit simulator, the authors verified that cell shunt and series resistances can indeed be responsible for the observed peak power efficiency vs. intensity behavior. The authors discuss the effect of basic cell diode parameters, i.e., shunt resistance, series resistance, and recombination losses, on PV module performance as a function of light intensity.

  19. Fractal Structures For Fixed Mems Capacitors

    KAUST Repository

    Elshurafa, Amro M.

    2014-08-28

    An embodiment of a fractal fixed capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure. The capacitor body has a first plate with a fractal shape separated by a horizontal distance from a second plate with a fractal shape. The first plate and the second plate are within the same plane. Such a fractal fixed capacitor further comprises a substrate above which the capacitor body is positioned.

  20. Fractal Structures For Fixed Mems Capacitors

    KAUST Repository

    Elshurafa, Amro M.; Radwan, Ahmed Gomaa Ahmed; Emira, Ahmed A.; Salama, Khaled N.

    2014-01-01

    An embodiment of a fractal fixed capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure. The capacitor body has a first plate with a fractal shape separated by a horizontal distance from a second plate with a fractal shape. The first plate and the second plate are within the same plane. Such a fractal fixed capacitor further comprises a substrate above which the capacitor body is positioned.

  1. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  2. A Generic Current Mode Design for Multifunction Grounded Capacitor Filters Employing Log-Domain Technique

    Directory of Open Access Journals (Sweden)

    N. A. Shah

    2011-01-01

    Full Text Available A generic design (GD for realizing an nth order log-domain multifunction filter (MFF, which can yield four possible stable filter configurations, each offering simultaneously lowpass (LP, highpass (HP, and bandpass (BP frequency responses, is presented. The features of these filters are very simple, consisting of merely a few exponential transconductor cells and capacitors; all grounded elements, capable of absorbing the shunt parasitic capacitances, responses are electronically tuneable, and suitable for monolithic integration. Furthermore, being designed using log-domain technique, it offers all its advantages. As an example, 5th-order MFFs are designed in each case and their performances are evaluated through simulation. Lastly, a comparative study of the MFFs is also carried, which helps in selecting better high-order MFF for a given application.

  3. High-energy power capacitors, their applied technology and the trends

    International Nuclear Information System (INIS)

    2012-01-01

    High-voltage and high-energy-density power capacitors called high-power ones such as film or electrolytic capacitors, have been used in large quantities for the pulse power technology such as an impulse current or voltage generator and a laser power supply, and for the power electronics one with progress of the power semiconductor device and the inverter technology. Recently, electric double layer capacitors (EDLC) with remarkable technical progress have been applied for the equipments of electric power and industrial field for the purpose of energy saving or electric power quality improvement, which have come to link to the electric power system. Thus, using a lot of high-power capacitors near our life would require to know the structure, the principle and the characteristic of capacitors, and also to consider suitable directions for use, maintenance and safety and so on, when carrying out a system and a facility design. In the technical report, while describing the dielectric and the feature of some high-power capacitors, and introducing the application examples to the laser-fusion power supply and some systems with EDLC, the trend of standardization of EDLC and the directivity of the examination about installation and maintenance of the applied equipments are described. (author)

  4. 30 CFR 57.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Electric Blasting-Surface and Underground § 57.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be...

  5. MR imaging of syringoperitoneal and syringosubarachnoid shunts

    International Nuclear Information System (INIS)

    Hasso, A.N.; Kucharczyk, W.; Mall, J.C.; Colombo, N.; Newton, T.H.; Norman, D.

    1986-01-01

    The authors utilized MR imaging for the evaluation of syringohydromelic shunt procedures in 16 patients. Four characteristic MR imaging findings were seen: ''tethering'' of the spinal cord posteriorly at the site of laminectomy and placement of the shunt tube distortion of the usual elliptical shape of the spinal cord at the site of the shunt, a ''snake-eyes'' appearance of the cord on transverse images which corresponded to the position of the shunt within or next to a collapsed syringohydromelic cavity, and a generous amount of subachnoid space surrounding the collapsed portion of the cavity. Occasionally the shunt could not be visualized on sagittal images but could be seen on transverse images. In the majority of cases, the MR imaging findings were sufficiently characteristic to warrant accurate diagnosis

  6. All-printed capacitors with continuous solution dispensing technology

    Science.gov (United States)

    Ge, Yang; Plötner, Matthias; Berndt, Andreas; Kumar, Amit; Voit, Brigitte; Pospiech, Doris; Fischer, Wolf-Joachim

    2017-09-01

    Printed electronics have been introduced into the commercial markets in recent years. Various printing technologies have emerged aiming to process printed electronic devices with low cost, environmental friendliness, and compatibility with large areas and flexible substrates. The aim of this study is to propose a continuous solution dispensing technology for processing all-printed thin-film capacitors on glass substrates using a leading-edge printing instrument. Among all printing technologies, this study provides concrete proof of the following outstanding advantages of this technology: high tolerance to inks, high throughput, low cost, and precise pattern transfers. Ag nanoparticle ink based on glycol ethers was used to print the electrodes. To obtain dielectric ink, a copolymer powder of poly(methyl methacrylate-co-benzoylphenyl methacrylate) containing crosslinkable side groups was dissolved in anisole. Various layouts were designed to support multiple electronic applications. Scanning electron microscopy and atomic force microscopy were used to investigate the all-printed capacitor layers formed using the proposed process. Additionally, the printed capacitors were electrically characterized under direct current and alternating current. The measured electrical properties of the printed capacitors were consistent with the theoretical results.

  7. A case of repeated intracerebral hemorrhages secondary to ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Jinbing Zhao

    2015-03-01

    Full Text Available Ventriculoperitoneal shunt is a routinely performed treatment in neurosurgical department. Intracerebral hemorrhage, as a complication after shunt catheterization, is really rare but with high mortality. In this study, we reported a case of a 74-year-old man who suffered from repeated intracerebral hemorrhage after ventriculoperitoneal shunt. The first hemorrhage happened 63 h after the 1st surgery, and most hematomas were located in the ipsilateral occipital lobe and intraventricles, along the ventricular catheter. Fresh blood clot casts blocked the external ventricular draining catheter, which was inserted into the right front horn during the 3rd surgery, indicating new intraventricular bleeding happened. A large hematoma in ipsilateral frontal lobe was detected on the 3rd day after the removal of external ventricular draining catheter. Different hemorrhagic locations and time points were encountered on the same case. We discussed the possible causes of repeated hemorrhage for this case, and the pre-operative preparation including risk evaluation in future clinical work.

  8. Ultra-Capacitor Energy Storage in a Large Hybrid Electric Bus

    Science.gov (United States)

    Viterna, L. A.

    1997-01-01

    The power requirements for inner city transit buses are characterized by power peaks about an order of magnitude larger than the average power usage of the vehicle. For these vehicles, hybrid power trains can offer significantly improved fuel economy and exhaust emissions. A critical design challenge, however, has been developing the energy storage and power management system to respond to these rapid power variations. Most hybrid vehicles today use chemical energy storage batteries to supplement the power from the fuel burning generator unit. Chemical storage batteries however, present several difficulties in power management and control. These difficulties include (1) inadequate life, (2) limited current delivery as well as absorption during regenerative braking, (3) inaccurate measurement of state of charge, and (4) stored energy safety issues. Recent advances in ultra-capacitor technology create an opportunity to address these concerns. The NASA Lewis Research Center, in cooperation with industry and academia, has developed an advanced hybrid electric transit bus using ultra-capacitors as the primary energy storage system. At over 15,000-kg gross weight, this is the largest vehicle of its kind ever built using this advanced energy storage technology. Results of analyses show that the vehicle will match the performance of an equivalent conventionally powered vehicle over typical inner city drive cycles. This paper describes the overall power system architecture, the evolution of the control strategy, and analysis of power flow and vehicle performance.

  9. Switched-capacitor isolated LED driver

    Science.gov (United States)

    Sanders, Seth R.; Kline, Mitchell

    2016-03-22

    A switched-capacitor voltage converter which is particularly well-suited for receiving a line voltage from which to drive current through a series of light emitting diodes (LEDs). Input voltage is rectified in a multi-level rectifier network having switched capacitors in an ascending-bank configuration for passing voltages in uniform steps between zero volts up to full received voltage V.sub.DC. A regulator section, operating on V.sub.DC, comprises switched-capacitor stages of H-bridge switching and flying capacitors. A current controlled oscillator drives the states of the switched-capacitor stages and changes its frequency to maintain a constant current to the load. Embodiments are described for isolating the load from the mains, utilizing an LC tank circuit or a multi-primary-winding transformer.

  10. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  11. Ventriculoperitoneal shunt infections in children

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... shunts: epidemiology, clinical manifestations and therapy.] Infecr Vis 1975;. 13: 543-552. 4. Odio C, McCracken GH jun, Nelson JD. CSF shunt infections in pediatrics, a seven-year experience. Am] Dis Child 1984; 138: 1103-1108. 5. Meirovitch J, Kitai-Cohen Y, Keren G, Fiendler G, Rubinstein E. Cerebro-.

  12. Fractal Structures For Mems Variable Capacitors

    KAUST Repository

    Elshurafa, Amro M.

    2014-08-28

    In accordance with the present disclosure, one embodiment of a fractal variable capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure, wherein the capacitor body has an upper first metal plate with a fractal shape separated by a vertical distance from a lower first metal plate with a complementary fractal shape; and a substrate above which the capacitor body is suspended.

  13. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...... side of the phase leg. The proposed method is subsequently used to balance the capacitor voltages using only the measured ac voltage. The operation of the proposed measurement and balancing method is independent of the number of the converter levels. Experimental results presented for a five-level FC...

  14. N-butyl cyanoacrylate embolization with blood flow control of an arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sonomura, Tetsuo; Kawai, Nobuyuki; Kishi, Kazushi [Wakayama Medical University, Wakayama (Japan); and others

    2014-04-15

    We present a case of a patient with rapid deterioration of esophageal varices caused by portal hypertension accompanied by a large arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma. We used n-butyl cyanoacrylate (NBCA) as an embolic material to achieve pinpoint embolization of the shunt, because the microcatheter tip was 2 cm away from the shunt site. Under hepatic arterial flow control using a balloon catheter, the arterioportal shunt was successfully embolized with NBCA, which caused an improvement in the esophageal varices.

  15. An experimental in-vivo canine model for adult shunt infection

    Directory of Open Access Journals (Sweden)

    Procop Gary

    2008-10-01

    Full Text Available Abstract Background Detailed human studies of the mechanisms and development of shunt infection in real time are not possible, and we have developed a canine hydrocephalus model to overcome this. The intention of this pilot study was to show that the canine hydrocephalus model could be shunted using conventional "human" shunts, and that a shunt infection could be established so that further studies could then be planned. Methods Hydrocephalus was induced in seven dogs (Canis familiaris by fourth ventricle obstruction. Four weeks later they were shunted using a Hakim Precision valve. Four of the dogs received shunts whose ventricular catheter had been inoculated with Staphylococcus epidermidis, and three were uninoculated controls. Four weeks after shunting the dogs were sacrificed and necropsy was performed. Removed shunts and tissue samples were examined microbiologically and isolates were subjected to detailed identification and genomic comparison. Results All the dogs remained well after shunting. Examination of removed shunt components revealed S. epidermidis in the brain and throughout the shunt system in the four inoculated animals, but in two of these Staphylococcus intermedius was also found. S. intermedius was also isolated from all three "negative" controls. There were slight differences between S. intermedius strains suggesting endogenous infection rather than cross- infection from a point source. Conclusion Shunt infection was established in the canine model, and had the experiment been extended beyond four weeks the typical microbiological, pathological and clinical features might have appeared. The occurrence of unplanned shunt infections in control animals due to canine normal skin flora reflects human clinical experience and underlines the usual source of bacteria causing shunt infection.

  16. Super miniaturization of film capacitor dielectrics

    Science.gov (United States)

    Lavene, B.

    1981-01-01

    The alignment of the stable electrical characteristics of film capacitors in the physical dimensions of ceramic and tantalum capacitors are discussed. The reliability of polycarbonate and mylar capacitors are described with respect to their compatibility with military specifications. Graphic illustrations are presented which show electrical and physical comparisons of film, ceramic, and tantalum capacitors. The major focus is on volumetric efficiency, weight reduction, and electrical stability.

  17. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    Science.gov (United States)

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical

  19. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  20. Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.

    Science.gov (United States)

    Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas

    2015-12-01

    Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.

  1. Portosystemic shunts for extrahepatic portal hypertension in children.

    Science.gov (United States)

    Tocornal, J; Cruz, F

    1981-07-01

    Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.

  2. Fractal Structures For Mems Variable Capacitors

    KAUST Repository

    Elshurafa, Amro M.; Radwan, Ahmed Gomaa Ahmed; Emira, Ahmed A.; Salama, Khaled N.

    2014-01-01

    In accordance with the present disclosure, one embodiment of a fractal variable capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure, wherein the capacitor body has an upper first metal plate with a fractal shape

  3. Faraday Rotator 5 kV Capacitor Bank

    International Nuclear Information System (INIS)

    Fetterman, C.C.

    1975-01-01

    A Faraday rotator 5 kV capacitor bank is a pulsed output power supply used to energize Faraday rotators for optical isolation in the ''LLL kJ Glass Laser System.'' Each supply contains either one, two or three parallel 240 μF storage capacitors depending on the size of the isolator used. Generally, the ''A*''(216 μH) isolator is energized with one capacitor, the ''A''(116 μH) isolator uses two capacitors and the ''B''(87 μH) isolator requires three capacitors. All models of isolators have been tested with four capacitors under maximum voltage and 25 feet of RG-217 cable with no hazardous effects. Except for the number of capacitors in each unit, the supplies are otherwise physically identical

  4. Comparison of modified driver circuit and capacitor-transfer circuit in longitudinally excited N2 laser.

    Science.gov (United States)

    Uno, Kazuyuki; Akitsu, Tetsuya; Nakamura, Kenshi; Jitsuno, Takahisa

    2013-04-01

    We developed a modified driver circuit composed of a capacitance and a spark gap, called a direct-drive circuit, for a longitudinally excited gas laser. The direct-drive circuit uses a large discharge impedance caused by a long discharge length of the longitudinal excitation scheme and eliminates the buffer capacitance used in the traditional capacitor-transfer circuit. We compared the direct-drive circuit and the capacitor-transfer circuit in a longitudinally excited N2 laser (wavelength: 337 nm). Producing high output energy with the capacitor-transfer circuit requires a large storage capacitance and a discharge tube with optimum dimensions (an inner diameter of 4 mm and a length of 10 cm in this work); in contrast, the direct-drive circuit requires a high breakdown voltage, achieved with a small storage capacitance and a large discharge tube. Additionally, for the same input energy of 792 mJ, the maximum output energy of the capacitor-transfer circuit was 174.2 μJ, and that of the direct-drive circuit was 344.7 μJ.

  5. Ferroelectric Fractional-Order Capacitors

    KAUST Repository

    Agambayev, Agamyrat; Patole, Shashikant P.; Farhat, Mohamed; Elwakil, Ahmed; Bagci, Hakan; Salama, Khaled N.

    2017-01-01

    Poly(vinylidene fluoride)-based polymers and their blends are used to fabricate electrostatic fractional-order capacitors. This simple but effective method allows us to precisely tune the constant phase angle of the resulting fractional-order capacitor by changing the blend composition. Additionally, we have derived an empirical relation between the ratio of the blend constituents and the constant phase angle to facilitate the design of a fractional order capacitor with a desired constant phase angle. The structural composition of the fabricated blends is investigated using Fourier transform infrared spectroscopy and X-ray diffraction techniques.

  6. Ferroelectric Fractional-Order Capacitors

    KAUST Repository

    Agambayev, Agamyrat

    2017-07-25

    Poly(vinylidene fluoride)-based polymers and their blends are used to fabricate electrostatic fractional-order capacitors. This simple but effective method allows us to precisely tune the constant phase angle of the resulting fractional-order capacitor by changing the blend composition. Additionally, we have derived an empirical relation between the ratio of the blend constituents and the constant phase angle to facilitate the design of a fractional order capacitor with a desired constant phase angle. The structural composition of the fabricated blends is investigated using Fourier transform infrared spectroscopy and X-ray diffraction techniques.

  7. Research on spark discharge of floating roof tank shunt

    International Nuclear Information System (INIS)

    Bi, Xiaolei; Liu, Quanzhen; Liu, Baoquan; Gao, Xin; Hu, Haiyan; Liu, Juan

    2013-01-01

    In order to quantitatively analyze the spark discharge risk of floating roof tank shunts, the breakdown voltage of shunt has been calculated by Townsend theory, the shunt spark discharge experiment is carried out by using 1.2/50 μs impulse voltage wave, and the relationship between breakdown voltage of shunt spark discharge and air gap is analyzed. It has been indicated by theoretical analysis and experimental study that the small gap is more easily cause spark discharge than the big gap when the contact between shunt and tank shell is poor. When air gap distance is equal to 0.1 cm, average breakdown voltage is 5280 V. When the air gap distance is less than 0.3 cm, experiment data agree well with Townsend theory. Therefore, in the condition of small gap, Townsend theory can be used to calculated breakdown voltage of shunt. Finally, based on the above conclusions, improvements for avoiding the spark discharge risk of shunt of floating roof tanks have been proposed.

  8. Spinal cord arteriovenous shunts: from imaging to management

    International Nuclear Information System (INIS)

    Rodesch, G.; Lasjaunias, P.

    2003-01-01

    Spinal cord arteriovenous shunts (SCAVSs) are either fistulas or niduses that can be separated in four different groups according to their localization and relationship to the dura. Paraspinal AVSs are located outside the spine and are responsible for neurological symptoms because of cord compression by ertatic veins, venous congestion or arterial steal. Epidural shunts are located in the epidural space and drain in epidural veins with secondary intradural congestion. Dural shunts are embedded in the dura, produce a cord venous myelopathy after draining through veins that either pierce the dura far from a nerve root or accompany a nerve root. Intradural shunts affect the cord, the roots or the filum. Additionally, they can be classified according to their potential relationships with genetics, vascular biological features and angiogenesis into genetic hereditary lesions (hereditary hemorrhagic telangiectasia), genetic non-hereditary lesions (multiple lesions with metameric links) and single lesions (AVMs or micro AVFs). MRI and MRA are able to visualise SCAVS early after the onset of clinical symptoms. The type of shunt and its localization may remain difficult to be precise. Angiography remains the gold standard for analysis of the anatomical, morphological and architectural features necessary for therapeutic decisions in both paediatric and adult populations. In our series, embolisation is chosen in first intention whatever the type of shunt responsible for the clinical symptoms and glue is preferably used. In paraspinal, dural or epidural arteriovenous shunts, the goal of treatment should be complete closure of the shunt. A complete cure by embolization is rather easily achieved in paraspinal lesions. Failure of endovascular therapy in dural or epidural shunts must bring the patient to surgery. The prognosis of most intradural shunts seems better than previously thought, even after haemorrhage. In intradural spinal cord arteriovenous shunts, embolisation

  9. Endoscopic Third Ventriculostomy in Previously Shunted Children

    Directory of Open Access Journals (Sweden)

    Eva Brichtova

    2013-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%. There were two serious complications (4.7%—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically.

  10. Embolization of nonvariceal portosystemic collaterals in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Arias, Mercedes; Longo, Jesus Maria; Alejandre, Pedro Luis; Betes, Maria Teresa; Elizalde, Arlette Maria

    1997-01-01

    Percutaneous embolization of large portosystemic collaterals was performed in three patients following placement of a transjugular intrahepatic portosystemic shunt in order to improve hepatopetal portal flow. Improved hepatic portal perfusion was achieved in these cases, thereby theoretically reducing the risk of chronic hepatic encephalopathy

  11. Electromechanical capacitor for energy transfer

    International Nuclear Information System (INIS)

    Carroll, T.A.; Chowdhuri, P.; Marshall, J.

    1983-01-01

    Inductive energy transfer between two magnets can be achieved with almost 100% efficiency with a transfer capacitor. However, the bulk and cost will be high, and reliability low if conventional capacitors are used. A homopolar machine, used as a capacitor, will be compact and economical. A homopolar machine was designed with counter-rotating copper disks completely immersed in a liquid metal (NaK-78) to work as a pulse capacitor. Absence of solid-brush collectors minimized wear and frictional losses. Wetting of the copper disks throughout the periphery by the liquid metal minimized the resistive losses at the collector interface. A liquid-metal collector would, however, introduce hydrodynamic and magnetohydrodynamic losses. The selected liquid metal, e.g., NaK-78 will produce the lowest of such losses among the available liquid metals. An electromechanical capacitor of this design was tested at various dc magnetic fields. Its measured capacitance was about 100 farads at a dc magnetic field of 1.15 tesla

  12. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-01-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts. (author)

  13. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-10-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts.

  14. Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.

    Science.gov (United States)

    Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M

    1999-09-01

    Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.

  15. Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.

  16. A Controller For The Three-phase To Three-phase Matrix Converter And For The Voltage Source Three-phase Inverter Without Dc-link Capacitor [um Controlador De Corrente De Carga Para O Conversor Em Matriz Trifásico Para Trifásico E Para O Inversor De Frequência Sem Capacitor Do Elo De Corrente Contínua

    OpenAIRE

    Filho M.E.O.; Gazoli J.R.; Filho A.J.S.; Ruppert E.

    2010-01-01

    Voltage source three-phase inverter plays an important role in modern industry. The conventional voltage source inverter has a large electrolytic capacitor as energy store element in order to keep the DC-link voltage constant. However, a large electrolytic capacitor increases the input current distortion. Replacing the large electrolytic capacitor by a small film capacitor, the input current quality is improved but the DC-link voltage and the output currents are distorted by low order harmoni...

  17. Evaluation of Polymer Hermetically Sealed Tantalum Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2014-01-01

    Polymer cathode tantalum capacitors have lower ESR (equivalent series resistance) compared to other types of tantalum capacitors and for this reason have gained popularity in the electronics design community. Their use allows improved performance of power supply systems along with substantial reduction of size and weight of the components used. However, these parts have poor thermal stability and can degrade in humid environments. Polymer hermetically sealed (PHS) capacitors avoid problems related to environmental degradation of molded case parts and can potentially replace current wet and solid hermetically sealed capacitors. In this work, PHS capacitors manufactured per DLA LAM DWG#13030 are evaluated for space applications. Several lots of capacitors manufactured over period from 2010 to 2014 were tested for the consistency of performance, electrical and thermal characteristics, highly accelerated life testing, and robustness under reverse bias and random vibration conditions. Special attention was given to analysis of leakage currents and the effect of long-term high temperature storage on capacitors in as is condition and after hermeticity loss. The results show that PHS capacitors might be especially effective for low-temperature applications or for system requiring a cold start-up. Additional screening and qualification testing have been recommended to assure the necessary quality of capacitors for space projects.

  18. The somatic shunt cable model for neurons.

    OpenAIRE

    Durand, D

    1984-01-01

    The derivation of the equations for an electrical model of nerve cells is presented. The model consists of an equivalent cylinder, a lumped somatic impedance, and a variable shunt at the soma. This shunt was introduced to take into account the fast voltage decays observed following the injections of current pulses in some motoneurons and hippocampal granule cells that could not be explained by existing models. The shunt can be interpreted either by penetration damage with the electrode or by ...

  19. Management of intracranial dural arteriovenous shunts in adults

    International Nuclear Information System (INIS)

    Sarma, Dipanka; Brugge, Karel ter

    2003-01-01

    Dural arteriovenous shunts are abnormal arteriovenous communications within the dura. They are thought to be an acquired condition in adults and can present with a variety of clinical features, ranging from benign bruits to intracranial hemorrhage and neurological deficits. The presentation and natural history of these shunts is largely determined by the pattern of venous drainage. Knowledge of natural history and careful study of the angioarchitexture by angiography is therefore mandatory for correct management of these lesions. In this review, principles of management in adults and the various factors that influence treatment decisions are discussed, with a focus on endovascular therapy. Retrograde leptomeningeal or cortical venous drainage has a strong correlation with adverse clinical events and the requirement for aggressive management in this situation is highlighted. Indications for endovascular treatment, therapeutic goals, approaches and techniques are reviewed. The role of surgical treatment is also briefly discussed

  20. Polyvinylidene fluoride film as a capacitor dielectric

    Science.gov (United States)

    Dematos, H. V.

    1981-01-01

    Thin strips of polyvinylidene fluoride film (PVDF) with vacuum deposited electrodes were made into capacitors by conventional winding and fabrication techniques. These devices were used to identify and evaluate the performance characteristics offered by the PVDF in metallized film capacitors. Variations in capacitor parameters with temperature and frequence were evaluated and compared with other dielectric films. Their impact on capacitor applications is discussed.

  1. Shunt protection for superconducting Maglev magnets

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L [Queen' s Univ., Kingston, Ontario (Canada). Dept. of Physics

    1979-09-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated.

  2. Shunt and series resistance of photovoltaic module evaluated from the I-V curve; I-V tokusei kara hyokashita taiyo denchi no shunt teiko to chokuretsu teiko

    Energy Technology Data Exchange (ETDEWEB)

    Asano, K; Kawamura, H; Yamanaka, S; Kawamura, H; Ono, H [Meijo University, Nagoya (Japan)

    1997-11-25

    With an objective of discussing I-V characteristics when a shadow has appeared on part of a photovoltaic module, evaluations were given as a first stage of the study on saturation current, shunt resistance and series resistance for the solar cell module. As a result of measuring change in amount of power generated in a sunny day with a shadow appearing over the solar cell module, reduction in power generation capability of about 23% was verified. In other words, the I-V characteristics of the solar cell module change largely because of existence of the shadow caused on the module. The I-V characteristics curve may be expressed and calculated as a function of the shunt resistance and series resistance. By curve-fitting measurement data for a case of changing insolation without existence of partial shadow, values of the shunt resistance and series resistance were derived. As a result, it was found that the calculations agree well with measurements. It was made also clear that each parameter shows temperature dependence. 6 refs., 10 figs., 1 tab.

  3. Case of right atrial myxoma with right to left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Kenji; Suzuki, Tomoyuki; Ohzeki, Tetsuro (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-12-01

    A case of 49-year-old woman with right atrial myxoma resulting to right to left shunt, diagnosed by cardiac pool isotope image, was reported. She was admitted to our clinic because of progressive shortness of breath. At admission lip cyanosis was noted. Laboratory data included polycythemia, low O/sub 2/ saturation (89%) and high erythrocyte sedimentation rate (65 mm/1 h). Chest x-p showed slight right atrial enlargement, but no pulmonary congestion. The electrocardiogram showed sinus regular rhythm with biphasic p wave in leads II, III, aVf. Although 1st heart sound at the apex was splited, no heart murmur was heard. In usual echocardiographic approach, no abnormal echogram was obtained in the right ventricular region. Lung perfusion scintiscan with Tc-99 m-MAA showed visualization of thyroid gland and kidney, which suggested intracardiac right-to-left shunt. Cardiac pool image with Tc-99m-HSA revealed large photo-deficient area in the right atrium and early visualization of aortic arch. Computor tomography showed large round low density region 8 x 7 cm in size. Based on their findings, this patient was diagnosed as right atrial tumor. At operation a large tumor (diameter 8 x 7 x 7 cm, weight 160g) filled the lower part of the right atrium and was adherent to the anterolateral wall in the right atrium. As a cause of R-L shunt, streched foramen ovale (5 x 10 mm) was found. Tumor histology was typical of atrial myxoma. Post-operative gated cardiac isotope image showed no evidence of residual atrial tumor. Cardiac blood pool isotope imaging was a method for the noninvasive detection and assessment of right atrial myxoma.

  4. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.

    Science.gov (United States)

    Jung, Nayoung; Kim, Dongwon

    2013-03-01

    To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

  5. Shunt protection for superconducting Maglev magnets

    International Nuclear Information System (INIS)

    Atherton, D.L.

    1979-01-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated. (author)

  6. Quasi-resonant converter with divided resonant capacitor on primary and secondary side

    OpenAIRE

    Shiroyama, Hironobu; Matsuo, Hirofumi; Ishizuka, Yoichi

    2009-01-01

    This paper presents a quasi-resonant converter with divided resonant capacitor on primary and secondary side of the isolation transformer. A conventional quasi-resonant converter using flyback topology can realize soft switching with simple circuit. However, relatively large surge voltage is generated in the switching device. To suppress such surge voltage, resonant capacitor is divided on primary side and secondary side in the proposed converter. In case of prototype 95W converter, the volta...

  7. DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Liu, Changjin; Xu, Dehong; Zhu, Nan

    2013-01-01

    Unbalanced grid voltage causes a large second-order harmonic current in the dc-link capacitors as well as dc-voltage fluctuation, which potentially will degrade the lifespan and reliability of the capacitors in voltage source converters. This paper proposes a novel dc-capacitor current control...... method for a grid-side converter (GSC) to eliminate the negative impact of unbalanced grid voltage on the dc-capacitors. In this method, a dc-capacitor current control loop, where a negative-sequence resonant controller is used to increase the loop gain, is added to the conventional GSC current control...... loop. The rejection capability to the unbalanced grid voltage and the stability of the proposed control system are discussed. The second-order harmonic current in the dc capacitor as well as dc-voltage fluctuation is very well eliminated. Hence, the dc capacitors will be more reliable under unbalanced...

  8. Mutual capacitor and its applications

    Directory of Open Access Journals (Sweden)

    Chun Li

    2014-06-01

    Full Text Available This study presents a new ac circuit element – the mutual capacitor, being a dual of the mutual inductor, which is also a new ac transformer. This element is characteristic of the mutual-capacitance coupling of a multi-capacitance system. A unity-coupled mutual capacitor works as an ideal current or voltage transformer, and incidentally acts as waveform separating when inductor employed or waveform converting from square-wave to quasi-sine or waveform filtering, between ports. As a transformer, the mutual capacitor is easy to design, easy for heat cooling, more accurate for current or voltage transformation, dissipating less energy as well as saving materials, suitable for high-power and high-voltage applications. Experiments to demonstrate performances of unity-coupled mutual capacitors are also given.

  9. Performance and Safety of Lithium-ion Capacitors

    Science.gov (United States)

    Jeevarajan, Judith A.; Martinez, Martin D.

    2014-01-01

    Lithium-ion capacitors (LIC) are a recent innovation in the area of supercapacitors and ultracapacitors. With an operating voltage range similar to that of lithium-ion batteries and a very low selfdischarge rate, these can be readily used in the place of batteries especially when large currents are required to be stored safely for use at a later time.

  10. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    International Nuclear Information System (INIS)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene; Monti, Cinzia; Bellomi, Massimo

    2002-01-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  11. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene [Division of Radiology, European Institute of Oncology, Milan (Italy); Monti, Cinzia [Institute of Radiology, University of Milan (Italy); Bellomi, Massimo [Division of Radiology, European Institute of Oncology, Milan (Italy); Institute of Radiology, University of Milan (Italy)

    2002-05-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  12. Radiologic follow-up of the transjugular intrahepatic stent-shunt (TIPSS)

    International Nuclear Information System (INIS)

    Hansmann, H.J.; Noeldge, G.; Leutloff, U.; Radeleff, B.; Richter, G.M.

    2001-01-01

    The transjugular intrahepatic stent-shunt (TIPSS) is a well accepted minimal invasive therapy for complications of portal hypertension: recurrent variceal bleeding, refractory ascites and liver failure due to the Budd-Chiari syndrome. The high frequency of shunt stenoses and occlusions makes regular follow up examinations essential. Despite modern non invasive imaging methods direct portography still is the gold standard for shunt surveillance in TIPSS. Ultrasound is helpful to detect shunt dysfunction, but nevertheless its failure rate is considerable despite the use of contrast enhancers such as Levovist because of anatomic and physical limitations, particularly when TIPSS-tracts deep in the liver are present. Reintervention rates approach 90-100% after 24 months, with 100% in child's A patients with comparatively good liver function. However, a strict shunt surveillance program with early portography and reintervention when necessary guarantees high clinical success rates associated with very low rebleeding rates below 10%. Overall the secondary success rate is 80%. Secondary failures are mainly caused by lack of patient compliance during follow-up. In a subgroup of patients no shunt maturation is observed, requiring multiple shunt revisions. In cases of recurrent shunt occlusions an association with bile leaks is presumed. In selected cases patients with chronically recurrent shunt stenosis or occlusions may benefit from placement of TIPSS stent grafts. (orig.) [de

  13. Physical and Electrical Characterization of Polymer Aluminum Capacitors

    Science.gov (United States)

    Liu, David; Sampson, Michael J.

    2010-01-01

    Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

  14. Physical and Electrical Characterization of Aluminum Polymer Capacitors

    Science.gov (United States)

    Liu, David; Sampson, Michael J.

    2010-01-01

    Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

  15. Nanostructured Electrode Materials for Electrochemical Capacitor Applications.

    Science.gov (United States)

    Choi, Hojin; Yoon, Hyeonseok

    2015-06-02

    The advent of novel organic and inorganic nanomaterials in recent years, particularly nanostructured carbons, conducting polymers, and metal oxides, has enabled the fabrication of various energy devices with enhanced performance. In this paper, we review in detail different nanomaterials used in the fabrication of electrochemical capacitor electrodes and also give a brief overview of electric double-layer capacitors, pseudocapacitors, and hybrid capacitors. From a materials point of view, the latest trends in electrochemical capacitor research are also discussed through extensive analysis of the literature and by highlighting notable research examples (published mostly since 2013). Finally, a perspective on next-generation capacitor technology is also given, including the challenges that lie ahead.

  16. Aqueous shunts for glaucoma.

    Science.gov (United States)

    Tseng, Victoria L; Coleman, Anne L; Chang, Melinda Y; Caprioli, Joseph

    2017-07-28

    Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. We included 27 trials with a total of 2099 participants with mixed diagnoses and comparisons of interventions. Seventeen studies reported adequate methods of randomization, and seven reported adequate allocation concealment. Data collection and follow-up times varied.Four trials compared an aqueous shunt (Ahmed or Baerveldt) with trabeculectomy, of which

  17. Resident-performed Ex-PRESS shunt implantation versus trabeculectomy.

    Science.gov (United States)

    Seider, Michael I; Rofagha, Soraya; Lin, Shan C; Stamper, Robert L

    2012-09-01

    To compare outcomes between resident-performed trabeculectomy and Ex-PRESS shunt implantation. A consecutive cohort of 36 Ex-PRESS shunt implantations and 57 trabeculectomies (1 eye/patient) performed by resident surgeons in their third year of ophthalmic training at the University of California, San Francisco and at the San Francisco Veterans Administration Hospital, under the supervision of a single glaucoma fellowship-trained surgeon were included in this study. Eyes with PRESS shunt groups at all follow-up points. On average, the Ex-PRESS shunt group required significantly less ocular antihypertensive medication to control IOP at 3 months postoperative (P=0.01), but no difference was found at 6 months or 1 year (all, P≥0.28). A larger proportion of Ex-PRESS shunt patients had good IOP control without medication at 3 (P=0.057) and 6 months (P=0.076) postoperatively. No difference was found in the rates of sight-threatening complications between groups (all, P≥0.22). In the hands of ophthalmology residents in their third year of training, the trabeculectomy and Ex-PRESS shunt implantation procedures perform comparably in terms of postoperative IOP control, reduction in patient dependence on ocular antihypertensive medications, and risk of complication in our population.

  18. Investigating PID Shunting in Polycrystalline Silicon Modules via Multiscale, Multitechnique Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Steven P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moseley, John [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Norman, Andrew [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnston, Steven [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Al-Jassim, Mowafak M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stokes, Adam [Colorado School of Mines; Gorman, Brian [Colorado School of Mines

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis. By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.

  19. Assessment Lumboperitoneal or Ventriculoperitoneal Shunt Patency by Radionuclide Technique: A Review Experience Cases

    International Nuclear Information System (INIS)

    Chiewvit, Sunanta; Nuntaaree, Sarun; Kanchaanapiboon, Potjanee; Chiewvit, Pipat

    2014-01-01

    Hydrocephalus-related symptoms that worsen after shunt placement may indicate a malfunctioning or obstructed shunt. The assessment of shunt patency and site of obstruction is important for planning of treatment. The radionuclide cerebrospinal fluid (CSF) shunt study provides a simple, effective, and low-radiation-dose method of assessing CSF shunt patency. The radionuclide CSF shuntography is a useful tool in the management of patients presenting with shunt-related problems not elucidated by conventional radiological examination. This article described the imaging technique of ventriculoperitoneal (VP) shunt and lumbar puncture (LP) shunt. The normal finding, abnormal finding of completed obstruction and partial obstruction is present by our cases experience. The radiopharmaceutical (Tc-99m diethylenetriaminepentaacetic acid) was injected via the reservoir for VP shunt and via lumbar puncture needle in subarachnoid space for LP shunt, then serial image in the head and abdominal area. The normal function of VP and LP shunt usually rapid spillage of the radioactivity in the abdominal cavity diffusely. The patent proximal tube VP shunt demonstrates ventricular reflux. The early image of patent LP shunt reveals no activity in the ventricular system contrast to distal LP shunt reveals early reflux of activity in the ventricular system. The completed distal VP and LP shunt obstruction show absence of tracer in the peritoneal area or markedly delayed appearance of abdominal activity. The partial distal VP and LP shunt obstruction recognized by slow transit or accumulation of tracer at the distal end or focal tracer in the peritoneal cavity near the tip of distal shunt. The images of the normal and abnormal CSF shunt as describe before are present in the full paper. Radionuclide CSF shuntography is a reliable and simple procedure for assessment shunt patency

  20. Hydrocephalus and Shunts

    Science.gov (United States)

    ... of a problem. Because of the complexity, a neurosurgeon is the best person to diagnosis and treat ... type of shunt is best for whom. So neurosurgeons usually pick ones that they think are best. ...

  1. Exercise-induced arteriovenous intrapulmonary shunting in dogs.

    Science.gov (United States)

    Stickland, Michael K; Lovering, Andrew T; Eldridge, Marlowe W

    2007-08-01

    We have previously shown, using contrast echocardiography, that intrapulmonary arteriovenous pathways are inducible in healthy humans during exercise; however, this technique does not allow for determination of arteriovenous vessel size or shunt magnitude. The purpose of this study was to determine whether large-diameter (more than 25 microm) intrapulmonary arteriovenous pathways are present in the dog, and whether exercise recruits these conduits. Through the right forelimb, 10.8 million 25-microm stable isotope-labeled microspheres (BioPAL, Inc., Worcester, MA) were injected either at rest (n = 8) or during high-intensity exercise (6- 8 mph, 10-15% grade, n = 6). Systemic arterial blood was continuously sampled during and for 3 minutes after injection. After euthanasia, tissue samples were obtained from the heart, liver, kidney, and skeletal muscle. In addition, 25- and 50-microm microspheres were infused into four isolated dog lungs that were ventilated and perfused at constant pressures similar to exercise. Blood and tissue samples were commercially analyzed for the presence of microspheres. No microspheres were detected in the arterial blood or tissue samples from resting dogs. In contrast, five of six exercising dogs showed evidence of exercise-induced intrapulmonary arteriovenous shunting, as microspheres were detected in arterial blood and/or tissue. Furthermore, shunt magnitude was calculated to be 1.4 +/- 0.8% of cardiac output (n = 3). Evidence of intrapulmonary arteriovenous anastomoses was also found in three of four isolated lungs. Consistent with previous human findings, these data demonstrate that intrapulmonary arteriovenous pathways are functional in the dog and are recruited with exercise.

  2. Diagnostics system for the 67 MJ, 50 kV pulsed power capacitor bank

    Energy Technology Data Exchange (ETDEWEB)

    Galakhov, I V; Gasheev, A S; Gruzin, I A; Gudov, S N; Murugov, V M; Osin, V A; Pankratov, V I; Pegoev, I N [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The diagnostics system is designed for charging and discharging to the load of the large 67 MJ and 50 kV capacitor bank for the iodine laser pulse power of ISKRA-5 facility. Discharging diagnostics of the capacitor bank uses a technique to measure a sequence of times between representative discharge events for 665 discharge circuits of the bank. Benefits of the measurement techniques are discussed. (author). 3 figs., 3 refs.

  3. Diagnostics system for the 67 MJ, 50 kV pulsed power capacitor bank

    International Nuclear Information System (INIS)

    Galakhov, I.V.; Gasheev, A.S.; Gruzin, I.A.; Gudov, S.N.; Murugov, V.M.; Osin, V.A.; Pankratov, V.I.; Pegoev, I.N.

    1996-01-01

    The diagnostics system is designed for charging and discharging to the load of the large 67 MJ and 50 kV capacitor bank for the iodine laser pulse power of ISKRA-5 facility. Discharging diagnostics of the capacitor bank uses a technique to measure a sequence of times between representative discharge events for 665 discharge circuits of the bank. Benefits of the measurement techniques are discussed. (author). 3 figs., 3 refs

  4. A Simple, Successful Capacitor Lab

    Science.gov (United States)

    Ennis, William

    2011-01-01

    Capacitors are a fundamental component of modern electronics. They appear in myriad devices and in an enormous range of sizes. Although our students are taught the function and analysis of capacitors, few have the opportunity to use them in our labs.

  5. ANN based controller for three phase four leg shunt active filter for power quality improvement

    Directory of Open Access Journals (Sweden)

    J. Jayachandran

    2016-03-01

    Full Text Available In this paper, an artificial neural network (ANN based one cycle control (OCC strategy is proposed for the DSTATCOM shunted across the load in three phase four wire distribution system. The proposed control strategy mitigates harmonic/reactive currents, ensures balanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage and compensates neutral current under varying source and load conditions. The proposed control strategy is superior over conventional methods as it eliminates, the sensors needed for sensing load current and coupling inductor current, in addition to the multipliers and the calculation of reference currents. ANN controllers are implemented to maintain voltage across the capacitor and as a compensator to compensate neutral current. The DSTATCOM performance is validated for all possible conditions of source and load by simulation using MATLAB software and simulation results prove the efficacy of the proposed control over conventional control strategy.

  6. Nanostructured Electrode Materials for Electrochemical Capacitor Applications

    Directory of Open Access Journals (Sweden)

    Hojin Choi

    2015-06-01

    Full Text Available The advent of novel organic and inorganic nanomaterials in recent years, particularly nanostructured carbons, conducting polymers, and metal oxides, has enabled the fabrication of various energy devices with enhanced performance. In this paper, we review in detail different nanomaterials used in the fabrication of electrochemical capacitor electrodes and also give a brief overview of electric double-layer capacitors, pseudocapacitors, and hybrid capacitors. From a materials point of view, the latest trends in electrochemical capacitor research are also discussed through extensive analysis of the literature and by highlighting notable research examples (published mostly since 2013. Finally, a perspective on next-generation capacitor technology is also given, including the challenges that lie ahead.

  7. Predicting ventriculoperitoneal shunt infection in children with hydrocephalus using artificial neural network.

    Science.gov (United States)

    Habibi, Zohreh; Ertiaei, Abolhasan; Nikdad, Mohammad Sadegh; Mirmohseni, Atefeh Sadat; Afarideh, Mohsen; Heidari, Vahid; Saberi, Hooshang; Rezaei, Abdolreza Sheikh; Nejat, Farideh

    2016-11-01

    The relationships between shunt infection and predictive factors have not been previously investigated using Artificial Neural Network (ANN) model. The aim of this study was to develop an ANN model to predict shunt infection in a group of children with shunted hydrocephalus. Among more than 800 ventriculoperitoneal shunt procedures which had been performed between April 2000 and April 2011, 68 patients with shunt infection and 80 controls that fulfilled a set of meticulous inclusion/exclusion criteria were consecutively enrolled. Univariate analysis was performed for a long list of risk factors, and those with p value < 0.2 were used to create ANN and logistic regression (LR) models. Five variables including birth weight, age at the first shunting, shunt revision, prematurity, and myelomeningocele were significantly associated with shunt infection via univariate analysis, and two other variables (intraventricular hemorrhage and coincided infections) had a p value of less than 0.2. Using these seven input variables, ANN and LR models predicted shunt infection with an accuracy of 83.1 % (AUC; 91.98 %, 95 % CI) and 55.7 % (AUC; 76.5, 95 % CI), respectively. The contribution of the factors in the predictive performance of ANN in descending order was history of shunt revision, low birth weight (under 2000 g), history of prematurity, the age at the first shunt procedure, history of intraventricular hemorrhage, history of myelomeningocele, and coinfection. The findings show that artificial neural networks can predict shunt infection with a high level of accuracy in children with shunted hydrocephalus. Also, the contribution of different risk factors in the prediction of shunt infection can be determined using the trained network.

  8. Electrical characterization of thin film ferroelectric capacitors

    NARCIS (Netherlands)

    Tiggelman, M.P.J.; Reimann, K.; Klee, M.; Beelen, D.; Keur, W.; Schmitz, Jurriaan; Hueting, Raymond Josephus Engelbart

    2006-01-01

    Tunable capacitors can be used to facilitate the reduction of components in wireless technologies. The tunability of the capacitors is caused by the sensitivity of the relative dielectric constant to a change in polarization with electric field. Thin film ferroelectric MIM capacitors on silicon

  9. Cortical herniation through compressive subdural membrane in an infant with a history of a large bihemispheric subdural hematoma and subdural-peritoneal shunt: case report.

    Science.gov (United States)

    Scoco, Aleka; Emily Bennett, E; Recinos, Violette

    2017-02-01

    Cortical herniation through subdural membrane formation is a rare complication of chronic subdural fluid collections and may occur following subdural shunting. The authors present a unique case of progressive cortical herniation through a compressive subdural membrane that occurred concomitant with a functioning subdural-peritoneal shunt.

  10. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    Bacterial infection is a major cause of shunt dysfunction. It is well-known that the majority of pathogenic micro-organisms are low-virulent bacteria normally found on intact skin. Probably shunts become contaminated during surgery either by contact to the patient skin, or contact from contaminated...... gloves or instruments. This study was performed to find out to what extent gloves become contaminated during shunt surgery. Gloves used during shunt implantation were examined in 10 operations. Shunt implantation was done using recommended precautions to avoid infection, including prophylactic...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  11. Experience and outcome of ventricular-atrial shunt: a multi centre study

    International Nuclear Information System (INIS)

    Akhtar, N.; Khan, A.A.; Yousaf, M.

    2015-01-01

    Ventriculoperitoneal (VP) shunt has been widely utilized in the treatment of hydrocephalus as a safe option but there is recent literature evidence that ventricularatrial (VA) shunt is not as notorious for its complications as proclaimed, to analyse and report our success with this procedure we conducted our study. Methods: A total of 64 patients undergoing VA shunting were included in this case series study conducted at RMC and Allied hospital Rawalpindi. The data was collected over a period of 4 years from, 1st June 2010 to 1st June 2015. Result: Our study included 64 patients who underwent a VA shunt for hydrocephalus. Their age ranged from 25 to 75 years. Most of the patients were females (60%). The following complications were observed with 2 (3.12%) patients having blockage of the shunt at the neck, 3 (4.68%) suffered from glomerulonephritis, 2 (3.1%) had post-operative neck hematoma, 4 (6.25 %) had wound infection, short lower end of the tube was found in 3 (4.68%), migrated lower end (into the subclavian) was seen in 1 (1.56%). Mortality was 1(1.56%). These results were comparable to other studies. Conclusion: Neurosurgeons have been doing a VA shunt as a second procedure, after a VP shunt when the need due to a complication was encountered. We however share our experience regarding ventriculo-atrial shunting, as first choice procedure, because of its low incidence of shunt blockage unlike VP shunt, which has high rate of shunt blockage and therefore warrants repeated surgeries. (author)

  12. Post V-P shunt surgical site EDH an uncommon complication: case report

    Directory of Open Access Journals (Sweden)

    Garg Manish

    2017-06-01

    Full Text Available ventriculoparitoneal shunt is well established modality of treatment for hydrocephalous. Complication of v-p shunt are also mentioned in literature like shunt infection shunt migration etc [8]. Here we are describing a rare complication of vp shunt which barely mentioned in literature. A 22 yr male admitted with complain of headache & vomiting patient was diagnosed to have tubercular meningities with hydrocephalous. Patient planned for ventriculoparietoneal shunt surgery and vp shunt was done. On 3rd post-surgery day patient develop weakness in Left side of body. Urgent ncct head done which showed EDH at surgical site. Immediate craniotomy and evacuation of hematoma was done patient improved and discharged. Thus we are discussing the importance of meticulous surgery for v-p shunt, post op ct scan and treatment.

  13. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  14. Shunt attachment and method for interfacing current collection systems

    Science.gov (United States)

    Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.

    1992-01-01

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.

  15. Vibration damping with negative capacitance shunts: theory and experiment

    International Nuclear Information System (INIS)

    De Marneffe, B; Preumont, A

    2008-01-01

    This paper analyzes in detail the enhancement of piezoelectric stack transducers by means of the well known 'negative' capacitive shunting. The stability is thoroughly studied: starting from the electrical admittance curve of the transducer, a method is introduced that quantifies the stability margins of the shunted structure. Two different implementations (series vs parallel) are investigated, and the lack of robustness of the parallel one is demonstrated. Next, this technique is experimentally applied on a truss structure. Its performances are compared with those of passive shunt circuits and with those of an active control law, the so-called Integral Force Feedback or IFF. As expected, the damping introduced by the negative capacitance shunt is larger than the damping obtained with the passive shunts; it remains, however, one order of magnitude smaller than that obtained with the IFF

  16. Genetic and Functional Analysis of Congenital Portosystemic Shunts in Dogs

    NARCIS (Netherlands)

    van den Bossche, L.

    2017-01-01

    The general aim of this thesis was to gain further insight into the pathogenesis of congenital portosystemic shunts (CPSS), elucidate mechanisms involved in the pathophysiology of CPSS, and explore predictors of recovery after surgical ligation of the shunt. For intrahepatic portosystemic shunts

  17. Physics of failure based analysis of aluminium electrolytic capacitor

    International Nuclear Information System (INIS)

    Sahoo, Satya Ranjan; Behera, S.K.; Kumar, Sachin; Varde, P.V.; Ravi Kumar, G.

    2016-01-01

    Electrolytic capacitors are one of the important devices in various power electronic systems, such as motor drives, uninterruptible power supply, electric vehicles and dc power supply. Electrolytic capacitors are also the integral part of many other electronic devices. One of the primary function of electrolytic capacitors is the smoothing of voltage ripple and storing electrical energy. However, the electrolytic capacitor has the shortest lifespan of components in power electronics. Past experiences show that electrolytic capacitor tends to degrade and fail faster under high electrical or thermal stress conditions during operations. The primary failure mechanism of an electrolytic capacitor is the evaporation of the electrolyte due to electrical or thermal overstress. This leads to the drift in the values of two important parameters-capacitance and equivalent series resistance (ESR) of the electrolytic capacitor. An attempt has been made to age the electrolytic capacitor and validate the results. The overall goal is to derive the accurate degradation model of the electrolytic capacitor. (author)

  18. Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.

    Science.gov (United States)

    Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis

    2016-10-01

    Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.

  19. Integrated capacitor arrangement for ultrahigh capacitance values

    NARCIS (Netherlands)

    Roozeboom, F.; Klootwijk, J.H.; Kemmeren, A.L.A.M.; Reefman, D.; Verhoeven, J.F.C.M.

    2011-01-01

    An electronic device includes at least one trench capacitor that can also take the form of an inverse structure, a pillar capacitor. An alternating layer sequence of at least two dielectric layers and at least two electrically conductive layers is provided in the trench capacitor or on the pillar

  20. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.

    Science.gov (United States)

    Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.

  1. Coupling slots without shunt impedance drop

    International Nuclear Information System (INIS)

    Balleyguier, P.

    1996-01-01

    It is well known that coupling slots between adjacent cells in a π-mode structure reduce shunt impedance per unit length with respect to single cell cavities. To design optimized coupling slots, one has to answer the following question: for a given coupling factor, what shape, dimension, position and number of slots lead to the lowest shunt impedance drop? A numerical study using the 3D code MAFIA has been carried out. The aim was to design the 352 MHz cavities for the high intensity proton accelerator of the TRISPAL project. The result is an unexpected set of four 'petal' slots. Such slots should lead to a quasi-negligible drop in shunt impedance: about -1% on average, for particle velocity from 0.4 c to 0.8 c. (author)

  2. Shoulder tip pain: an under-reported complication of ventriculoperitoneal shunt.

    LENUS (Irish Health Repository)

    Lim, C

    2012-02-03

    Ventriculoperitoneal (VP) shunt insertion is the commonest form of treatment for hydrocephalus. Shoulder tip pain after VP shunt insertion is unusual and has only recently been reported. We present a case of excruciating shoulder tip pain due to diaphragmatic irritation after VP shunt insertion.

  3. Programmable shunts and headphones: Are they safe together?

    Science.gov (United States)

    Spader, Heather S; Ratanaprasatporn, Linda; Morrison, John F; Grossberg, Jonathan A; Cosgrove, G Rees

    2015-10-01

    Programmable shunts have a valuable role in the treatment of patients with hydrocephalus, but because a magnet is used to change valve settings, interactions with external magnets may reprogram these shunts. Previous studies have demonstrated the ability of magnetic toys and iPads to erroneously reprogram shunts. Headphones are even more ubiquitous, and they contain an electromagnet for sound projection that sits on the head very close to the shunt valve. This study is the first to look at the magnetic field emissions of headphones and their effect on reprogrammable shunt valves to ascertain whether headphones are safe for patients with these shunts to wear. In this in vitro study of the magnetic properties of headphones and their interactions with 3 different programmable shunts, the authors evaluated Apple earbuds, Beats by Dr. Dre, and Bose QuietComfort Acoustic Noise Cancelling headphones. Each headphone was tested for electromagnetic field emissions using a direct current gaussmeter. The following valves were evaluated: Codman Hakim programmable valve, Medtronic Strata II valve, and Aesculap proGAV. Each valve was tested at distances of 0 to 50 mm (in 5-mm increments) from each headphone. The exposure time at each distance was 1 minute, and 3 trials were performed to confirm results at each valve setting and distance. All 3 headphones generated magnetic fields greater than the respective shunt manufacturer's recommended strength of exposure, but these fields did not persist beyond 5 mm. By 2 cm, the fields levels were below 20 G, well below the Medtronic recommendation of 90 G and the Codman recommendation of 80 G. Because the mechanism for the proGAV is different, there is no recommended gauss level. There was no change in gauss-level emissions by the headphones with changes in frequency and amplitude. Both the Strata and Codman-Hakim valves were reprogrammed by direct contact (distance 0 mm) with the Bose headphones. When a rotation component was added, all

  4. Optimization methods for the Train Unit Shunting Problem

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin; Wagenaar, Joris Camiel

    2017-01-01

    We consider the Train Unit Shunting Problem, an important planning problem for passenger railway operators. This problem entails assigning train units from shunting yards to scheduled train services in such a way that the resulting operations are without conflicts. The problem arises at every...... shunting yard in the railway network and involves matching train units to arriving and departing train services as well as assigning the selected matchings to appropriate shunting yard tracks. We present an extensive comparison benchmark of multiple solution approaches for this problem, some of which...... are novel. In particular, we develop a constraint programming formulation, a column generation approach, and a randomized greedy heuristic. We compare and benchmark these approaches with two existing methods, a mixed integer linear program and a two-stage heuristic. The benchmark contains multiple real...

  5. Capacitor requirements for controlled thermonuclear experiments and reactors

    International Nuclear Information System (INIS)

    Boicourt, G.P.; Hoffman, P.S.

    1975-01-01

    Future controlled thermonuclear experiments as well as controlled thermonuclear reactors will require substantial numbers of capacitors. The demands on these units are likely to be quite severe and quite different from the normal demands placed on either present energy storage capacitors or present power factor correction capacitors. It is unlikely that these two types will suffice for all necessary Controlled Thermonuclear Research (CTR) applications. The types of capacitors required for the various CTR operating conditions are enumerated. Factors that influence the life, cost and operating abilities of these types of capacitors are discussed. The problems of capacitors in a radiation environment are considered. Areas are defined where future research is needed. Some directions that this research should take are suggested. (U.S.)

  6. Capacitor requirements for controlled thermonuclear experiments and reactors

    International Nuclear Information System (INIS)

    Boicourt, G.P.; Hoffman, P.S.

    1975-01-01

    Future controlled thermonuclear experiments as well as controlled thermonuclear reactors will require substantial numbers of capacitors. The demands on these units are likely to be quite severe and quite different from the normal demands placed on either present energy storage capacitors or present power factor correction capacitors. It is unlikely that these two types will suffice for all necessary Controlled Thermonuclear Research (CTR) applications. The types of capacitors required for the various CTR operating conditions are enumerated. Factors that influence the life, cost and operating abilities of these types of capacitors are discussed. The problems of capacitors in a radiation environment are considered. Areas are defined where future research is needed. Some directions that this research should take are suggested

  7. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  8. Ferroelectric capacitor with reduced imprint

    Science.gov (United States)

    Evans, Jr., Joseph T.; Warren, William L.; Tuttle, Bruce A.; Dimos, Duane B.; Pike, Gordon E.

    1997-01-01

    An improved ferroelectric capacitor exhibiting reduced imprint effects in comparison to prior art capacitors. A capacitor according to the present invention includes top and bottom electrodes and a ferroelectric layer sandwiched between the top and bottom electrodes, the ferroelectric layer comprising a perovskite structure of the chemical composition ABO.sub.3 wherein the B-site comprises first and second elements and a dopant element that has an oxidation state greater than +4. The concentration of the dopant is sufficient to reduce shifts in the coercive voltage of the capacitor with time. In the preferred embodiment of the present invention, the ferroelectric element comprises Pb in the A-site, and the first and second elements are Zr and Ti, respectively. The preferred dopant is chosen from the group consisting of Niobium, Tantalum, and Tungsten. In the preferred embodiment of the present invention, the dopant occupies between 1 and 8% of the B-sites.

  9. Design and fabrication of a continuously tuned capacitor by microfluidic actuation

    Science.gov (United States)

    Habbachi, Nizar; Boussetta, Hatem; Boukabache, Ali; Adel Kallala, Mohamed; Pons, Patrick; Besbes, Kamel

    2018-03-01

    This paper presents the design and fabrication of a continuously tunable RF MEMS capacitor using micro fluidics as a tuning parameter. The impedance variation principle is based on the modification of the capacitor gap permittivity produced by the presence of deionized (DI) water and its displacement in a channel inserted between electrodes. In addition, the electric field distribution changes in an equiponderant way according to the DI water positions in the channel. This change modifies the capacitive coupling, the stored energy and, consequently, the self-resonant frequency. The fabrication process is based on two parts: metallic paths having a spiral form, and obtained by electroplating a 7 µm thick gold layer to constitute electrodes; and fluidic channels, realized by super imposing two SU-8 films. The measurements show a nonlinear variation of the capacitor value according to the water positions. The tuning range is very large, reaching to 4650% for capacitance, and 335% for resonant frequency. However, the quality factor reaches Q max  =  79 at 550 MHz if the capacitor is empty and decreases with the fluid displacement to Q min  =  3.13.

  10. Capacitor discharges, magnetohydrodynamics, X-rays, ultrasonics

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology, Volume 1: Capacitor Discharges - Magnetohydrodynamics - X-Rays - Ultrasonics deals with the theoretical and engineering problems that arise in the capacitor discharge technique.This book discusses the characteristics of dielectric material, symmetrical switch tubes with mercury filling, and compensation conductor forms. The transformed discharge for highest current peaks, ignition transformer for internal combustion engines, and X-ray irradiation of subjects in mechanical motion are also elaborated. This text likewise covers the transformed capacitor discharge in w

  11. Method of manufacturing a shapeable short-resistant capacitor

    Science.gov (United States)

    Taylor, Ralph S.; Myers, John D.; Baney, William J.

    2013-04-02

    A method that employs a novel combination of conventional fabrication techniques provides a ceramic short-resistant capacitor that is bendable and/or shapeable to provide a multiple layer capacitor that is extremely compact and amenable to desirable geometries. The method allows thinner and more flexible ceramic capacitors to be made. The method includes forming a first thin metal layer on a substrate; depositing a thin, ceramic dielectric layer over the metal layer; depositing a second thin metal layer over the dielectric layer to form a capacitor exhibiting a benign failure mode; and separating the capacitor from the substrate. The method may also include bending the resulting capacitor into a serpentine arrangement with gaps between the layers that allow venting of evaporated electrode material in the event of a benign failure.

  12. Capacitor blocks for linear transformer driver stages.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Kumpyak, E V; Smorudov, G V; Zherlitsyn, A A

    2014-01-01

    In the Linear Transformer Driver (LTD) technology, the low inductance energy storage components and switches are directly incorporated into the individual cavities (named stages) to generate a fast output voltage pulse, which is added along a vacuum coaxial line like in an inductive voltage adder. LTD stages with air insulation were recently developed, where air is used both as insulation in a primary side of the stages and as working gas in the LTD spark gap switches. A custom designed unit, referred to as a capacitor block, was developed for use as a main structural element of the transformer stages. The capacitor block incorporates two capacitors GA 35426 (40 nF, 100 kV) and multichannel multigap gas switch. Several modifications of the capacitor blocks were developed and tested on the life time and self breakdown probability. Blocks were tested both as separate units and in an assembly of capacitive module, consisting of five capacitor blocks. This paper presents detailed design of capacitor blocks, description of operation regimes, numerical simulation of electric field in the switches, and test results.

  13. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt

    Science.gov (United States)

    Lutz, Barry R.; Venkataraman, Pranav; Browd, Samuel R.

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a “smart shunt” that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care. PMID:23653889

  14. Multilayer ceramic capacitors for pulsed power, high temperature applications

    International Nuclear Information System (INIS)

    Cygan, S.; McLarney, J.; Prymak, J.; Bohn, P.

    1991-01-01

    The performance of the multilayer ceramic capacitors (MLC) in high frequency power applications has improved significantly over the last years. One of the possible applications of MLC capacitors is the automotive industry where repetitive discharging of capacitors is required. A 0.25-μF capacitor using NPO dielectric subjected to repetitive discharging with the rate of 700 pulses per second, magnitude of 600-V and 195-A peak currents showed no degradation in performance at 298 K or 398 K even after 1 billion discharge cycles. Less than a 5-K temperature rise was observed under these conditions. The most exciting, newly emerging utilization for MLC capacitors, however, might be the high temperature application (up to 473 K for underhood utilization), where ceramic capacitors with higher volumetric efficiency as compared to glass or polymer type capacitors prove very superior. Moreover ceramic capacitors, which next to glass capacitors exhibit the greatest radiation resistance among all insulating materials (Hanks and Hamman 1971), might also be best suited in the future for high temperature operation in space environment. The pulsed power performance of the 0.25-μF NPO capacitor was evaluated under repetitive discharge conditions (200 V, 700 pps) at high temperature, 473 K, and the results are presented in this paper

  15. Predictors of Shunt Dysfunction and Overall Survival in Patients with Variceal Bleeding Treated with Transjugular Portosystemic Shunt Creation Using the Fluency Stent Graft.

    Science.gov (United States)

    Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui

    2018-01-16

    Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. New Temperature-Insensitive Electronically-Tunable Grounded Capacitor Simulator

    OpenAIRE

    Abuelma'atti, Muhammad Taher; Khan, Muhammad Haroon

    1996-01-01

    A new circuit for simulating a grounded capacitor is presented. The circuit uses one operationalamplifier (OA), three operational-transconductance amplifiers (OTAs), and one capacitor. The realized capacitor is temperature-insensitive and electronically tunable. Experimental results are included.

  17. Risk factors for shunt malfunction in pediatric hydrocephalus: a multicenter prospective cohort study.

    Science.gov (United States)

    Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D

    2016-04-01

    OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.

  18. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Energy Technology Data Exchange (ETDEWEB)

    Coekeliler, D [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey); Caner, H [Department of Neurosurgery, School of Medicine, Baskent University, 06610, Ankara (Turkey); Zemek, J [Institute of Physics, Academy of Sciences of the Czech Republic, Cukrovarnicka 10, 162 53, Prague, Czech Republic (Czech Republic); Choukourov, A [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Biederman, H [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Mutlu, M [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey)

    2007-03-01

    Prosthetic devices, mainly shunts, are frequently used for temporary or permanent drainage of cerebrospinal fluid. The pathogenesis of shunt infection is a very important problem in modern medicine and generally this is characterized by staphylococcal adhesion to the cerebrospinal fluid shunt surfaces. In this paper, the prevention of the attachment of test microorganism Staphylococcus epidermidis on the cerebrospinal fluid shunt surfaces by 2-hydroxyethylmethacrylate (HEMA) precursor modification in the plasma polymerization system, is reported. Different plasma polymerization conditions (RF discharge power 10-20-30 W, exposure time 5-10-15 min) were employed during the surface modification. The surface chemistry and topology of unmodified and modified shunts was characterized by x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Also, static contact angle measurements were performed to state the change of surface hydrophilicity. All samples were tested in vitro with Staphylococcus epidermidis. A plasma-polymerized HEMA film (PP HEMA) was found to be an alternative simple method to decrease the microorganism attachment and create bacterial anti-fouling surfaces. The attachment of the model microorganism Staphylococcus epidermidis on the shunt surface modified by PP HEMA at 20 W and 15 min was reduced 62.3% if compared to the unmodified control surface of the shunt.

  19. Electric field mapping inside metallized film capacitors

    DEFF Research Database (Denmark)

    Nielsen, Dennis Achton; Popok, Vladimir; Pedersen, Kjeld

    2015-01-01

    (s) they suffered from accelerated testing. We have prepared film capacitors for analysis by micro-sectioning and verified the quality of the preparation procedure using optical and atomic force microscopy. The potential distribution in the layer structure (alternating 7 µm thick dielectric and 50-100 nm thick...... and durability and serves as verification that failure- and degradation mechanisms remain the same at different stress levels during accelerated testing. In this work we have used Kelvin probe force microscopy (KPFM) to analyze metallized film capacitors with the purpose of determining the degradation mechanism...... metal) of a new capacitor was used as reference. KPFM measurements on the degraded capacitors showed a change in contact potential difference from -0.61V on the reference capacitor to 3.2V on the degraded ones, indicating that corrosion of the metallization had happened. Studies also showed that some...

  20. Studying DAC capacitor-array degradation in charge-redistribution SAR ADCs

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2014-01-01

    In this paper, system-level behavioural models are used to simulate the aging-related degradation effects in the DAC capacitor array of a charge-redistribution successive approximation register (SAR) ADC because of the large calculation time of transistor-level aging simulators. A

  1. Calibration of piezoelectric RL shunts with explicit residual mode correction

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2017-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained by an exte......Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained...... by an extension of the local piezoelectric transducer displacement by two additional terms, representing the flexibility and inertia contributions from the residual vibration modes not directly addressed by the shunt damping. This results in an augmented dynamic model for the targeted resonant vibration mode...

  2. Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines.

    Science.gov (United States)

    Swetapadma, Aleena; Yadav, Anamika

    2015-01-01

    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance.

  3. Method of manufacturing a capacitor on a nanowire and integrated circuit having such a capacitor

    NARCIS (Netherlands)

    2009-01-01

    A method of manufacturing a capacitor on a wafer, and an IC comprising such a capacitor is disclosed. The method comprises forming a plurality of vertical structures (140) each having a sub-micron thickness on the wafer; and growing a metal-insulator-metal (MIM) stack (150) over the plurality of

  4. An unusual case of intrahepatic portosystemic venous shunt

    African Journals Online (AJOL)

    vena cava (IVC) (most common). Intrahepatic portosystemic venous shunts are rare vascular anomalies that may be detected in asymptomatic patients, given the recent advances in radiological imaging techniques. Accurate shunt evaluation and classification can be performed with ultrasound and multi-detector computed.

  5. A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

    Science.gov (United States)

    Duenges, Bastian; Vogt, Andreas; Bodenstein, Marc; Wang, Hemei; Böhme, Stefan; Röhrig, Bernd; Baumgardner, James E; Markstaller, Klaus

    2009-12-01

    The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model. To allow a broad variance of atelectasis and therefore shunt fraction, 8 sham animals did not receive lavage, and 8 animals were treated by lung lavages with 30 mL/kg warmed lactated Ringer's solution as follows: 2 animals were lavaged once, 5 animals twice, and 1 animal 3 times. Variables were recorded at baseline and twice after induction of lung injury (T1 and T2). Retention data of sulfur hexafluoride, krypton, desflurane, enflurane, diethyl ether, and acetone were analyzed by MMIMS, and M-S was derived using a known algorithm for the multiple inert gas elimination technique. Standard formulas were used for the calculation of R-S. Forty-four pairs of M-S and R-S were recorded. M-S ranged from 0.1% to 35.4% and R-S from 3.7% to 62.1%. M-S showed a correlation with R-S described by linear regression: M-S = -4.26 + 0.59 x R-S (r(2) = 0.83). M-S was on average lower than R-S (mean = -15.0% CO, sd = 6.5% CO, and median = -15.1), with lower and upper limits of agreement of -28.0% and -2.0%, respectively. The lower and upper limits of the 95% confidence intervals were -17.0 and -13.1 (P < 0.001, Student's t-test). Shunt derived from MMIMS inert gas retention data correlated well with R-S during breathing of oxygen. Shunt as derived by MMIMS was generally less than R-S.

  6. High energy, low inductance, high current fiberglass energy storage capacitor for the Atlas Machine Marx modules

    CERN Document Server

    Cooper, R A; Ennis, J B; Cochrane, J C; Reass, W A; Parsons, W M

    1999-01-01

    The Los Alamos National Laboratory's Atlas Marx design team envisioned a double ended plastic case 60 kV, 15 nH, 650 kA, energy storage capacitor. A design specification was established and submitted to various vendors. Maxwell Energy Products drew from its development of large fiberglass case, high voltage, low inductance "FASTCAP" capacitors manufactured for Maxwell Technologies' ACE II, ACE III and ACE IV machines. This paper discusses the LANL specification and Maxwell Energy Products' successful design, Model No. 39232, 34.1 mu F, 60 kV, 13*29*27", the only capacitor qualified by LANL for the 23 Mega Joule Atlas application. Maxwell's past experience in this type of capacitor is covered. The performance data is reviewed and the life test data compared to the original calculated design life. Challenges included Maxwell's "keep it simple " design goal which was maintained to minimize the effort required to create and manufacture a nearly 600 pound capacitor. (1 refs).

  7. Protection of MOS capacitors during anodic bonding

    Science.gov (United States)

    Schjølberg-Henriksen, K.; Plaza, J. A.; Rafí, J. M.; Esteve, J.; Campabadal, F.; Santander, J.; Jensen, G. U.; Hanneborg, A.

    2002-07-01

    We have investigated the electrical damage by anodic bonding on CMOS-quality gate oxide and methods to prevent this damage. n-type and p-type MOS capacitors were characterized by quasi-static and high-frequency CV-curves before and after anodic bonding. Capacitors that were bonded to a Pyrex wafer with 10 μm deep cavities enclosing the capacitors exhibited increased leakage current and interface trap density after bonding. Two different methods were successful in protecting the capacitors from such damage. Our first approach was to increase the cavity depth from 10 μm to 50 μm, thus reducing the electric field across the gate oxide during bonding from approximately 2 × 105 V cm-1 to 4 × 104 V cm-1. The second protection method was to coat the inside of a 10 μm deep Pyrex glass cavity with aluminium, forming a Faraday cage that removed the electric field across the cavity during anodic bonding. Both methods resulted in capacitors with decreased interface trap density and unchanged leakage current after bonding. No change in effective oxide charge or mobile ion contamination was observed on any of the capacitors in the study.

  8. High power density capacitor and method of fabrication

    Science.gov (United States)

    Tuncer, Enis

    2012-11-20

    A ductile preform for making a drawn capacitor includes a plurality of electrically insulating, ductile insulator plates and a plurality of electrically conductive, ductile capacitor plates. Each insulator plate is stacked vertically on a respective capacitor plate and each capacitor plate is stacked on a corresponding insulator plate in alignment with only one edge so that other edges are not in alignment and so that each insulator plate extends beyond the other edges. One or more electrically insulating, ductile spacers are disposed in horizontal alignment with each capacitor plate along the other edges and the pattern is repeated so that alternating capacitor plates are stacked on alternating opposite edges of the insulator plates. A final insulator plate is positioned at an extremity of the preform. The preform may then be drawn to fuse the components and decrease the dimensions of the preform that are perpendicular to the direction of the draw.

  9. Super capacitor modeling with artificial neural network (ANN)

    Energy Technology Data Exchange (ETDEWEB)

    Marie-Francoise, J.N.; Gualous, H.; Berthon, A. [Universite de Franche-Comte, Lab. en Electronique, Electrotechnique et Systemes (L2ES), UTBM, INRETS (LRE T31) 90 - Belfort (France)

    2004-07-01

    This paper presents super-capacitors modeling using Artificial Neural Network (ANN). The principle consists on a black box nonlinear multiple inputs single output (MISO) model. The system inputs are temperature and current, the output is the super-capacitor voltage. The learning and the validation of the ANN model from experimental charge and discharge of super-capacitor establish the relationship between inputs and output. The learning and the validation of the ANN model use experimental results of 2700 F, 3700 F and a super-capacitor pack. Once the network is trained, the ANN model can predict the super-capacitor behaviour with temperature variations. The update parameters of the ANN model are performed thanks to Levenberg-Marquardt method in order to minimize the error between the output of the system and the predicted output. The obtained results with the ANN model of super-capacitor and experimental ones are in good agreement. (authors)

  10. Evaluation of Commercial Automotive-Grade BME Capacitors

    Science.gov (United States)

    Liu, Donhang

    2014-01-01

    Three Ni-BaTiO3 ceramic capacitor lots with the same specification (chip size, capacitance, and rated voltage) and the same reliability level, made by three different manufacturers, were degraded using highly accelerated life stress testing (HALST) with the same temperature and applied voltage conditions. The reliability, as characterized by mean time to failure (MTTF), differed by more than one order of magnitude among the capacitor lots. A theoretical model based on the existence of depletion layers at grain boundaries and the entrapment of oxygen vacancies has been proposed to explain the MTTF difference among these BME capacitors. It is the conclusion of this model that reliability will not be improved simply by increasing the insulation resistance of a BME capacitor. Indeed, Ni-BaTiO3 ceramic capacitors with a smaller degradation rate constant K will always give rise to a longer reliability life.

  11. 2014 NEPP Tasks Update for Ceramic and Tantalum Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2014-01-01

    Presentation describes recent development in research on MnO2, wet, and polymer tantalum capacitors. Low-voltage failures in multilayer ceramic capacitors and techniques to reveal precious metal electrode (PME) and base metal electrode (BME) capacitors with cracks are discussed. A voltage breakdown technique is suggested to select high quality low-voltage BME ceramic capacitors.

  12. Uterine perforation by a cystoperitoneal shunt, an unusual cause of recurrent vaginal discharge.

    Science.gov (United States)

    Poilblanc, Mathieu; Sentilhes, Loïc; Mercier, Philippe; Lefèbvre, Céline; Descamps, Philippe

    2012-01-01

    We describe the first reported case of uterine perforation by a cystoperitoneal shunt. The mechanism of this unusual complication is unclear. A 17-year-old patient had a cystoperitoneal shunt for a porencephalic cyst. She presented with recurrent watery vaginal discharge. A pelvic ultrasound examination showed that the uterus had been perforated by the distal tip of the shunt. The cystoperitoneal shunt was converted to a ventriculo-atrial shunt, and the vaginal discharge subsequently resolved. The appearance of light and clear vaginal discharge in a patient with a cystoperitoneal shunt raises the possibility of uterine perforation. This can be confirmed by ultrasound and analysis of the discharge. Removal of the shunt leads to spontaneous closure of the uterine defect.

  13. Physicochemical assessment criteria for high-voltage pulse capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Darian, L. A., E-mail: LDarian@rambler.ru; Lam, L. Kh. [National Research University, Moscow Power Engineering Institute (Russian Federation)

    2016-12-15

    In the paper, the applicability of decomposition products of internal insulation of high-voltage pulse capacitors is considered (aging is the reason for decomposition products of internal insulation). Decomposition products of internal insulation of high-voltage pulse capacitors can be used to evaluate their quality when in operation and in service. There have been three generations of markers of aging of insulation as in the case with power transformers. The area of applicability of markers of aging of insulation for power transformers has been studied and the area can be extended to high-voltage pulse capacitors. The research reveals that there is a correlation between the components and quantities of markers of aging of the first generation (gaseous decomposition products of insulation) dissolved in insulating liquid and the remaining life of high-voltage pulse capacitors. The application of markers of aging to evaluate the remaining service life of high-voltage pulse capacitor is a promising direction of research, because the design of high-voltage pulse capacitors keeps stability of markers of aging of insulation in high-voltage pulse capacitors. It is necessary to continue gathering statistical data concerning development of markers of aging of the first generation. One should also carry out research aimed at estimation of the remaining life of capacitors using markers of the second and the third generation.

  14. Physicochemical assessment criteria for high-voltage pulse capacitors

    International Nuclear Information System (INIS)

    Darian, L. A.; Lam, L. Kh.

    2016-01-01

    In the paper, the applicability of decomposition products of internal insulation of high-voltage pulse capacitors is considered (aging is the reason for decomposition products of internal insulation). Decomposition products of internal insulation of high-voltage pulse capacitors can be used to evaluate their quality when in operation and in service. There have been three generations of markers of aging of insulation as in the case with power transformers. The area of applicability of markers of aging of insulation for power transformers has been studied and the area can be extended to high-voltage pulse capacitors. The research reveals that there is a correlation between the components and quantities of markers of aging of the first generation (gaseous decomposition products of insulation) dissolved in insulating liquid and the remaining life of high-voltage pulse capacitors. The application of markers of aging to evaluate the remaining service life of high-voltage pulse capacitor is a promising direction of research, because the design of high-voltage pulse capacitors keeps stability of markers of aging of insulation in high-voltage pulse capacitors. It is necessary to continue gathering statistical data concerning development of markers of aging of the first generation. One should also carry out research aimed at estimation of the remaining life of capacitors using markers of the second and the third generation.

  15. Tube-Super Dielectric Materials: Electrostatic Capacitors with Energy Density Greater than 200 J·cm-3.

    Science.gov (United States)

    Cortes, Francisco Javier Quintero; Phillips, Jonathan

    2015-09-17

    The construction and performance of a second generation of super dielectric material based electrostatic capacitors (EC), with energy density greater than 200 J·cm - ³, which rival the best reported energy density of electric double layer capacitors (EDLC), also known as supercapacitors, are reported. The first generation super dielectric materials (SDM) are multi-material mixtures with dielectric constants greater than 1.0 × 10⁵, composed of a porous, electrically insulating powder filled with a polarizable, ion-containing liquid. Second-generation SDMs (TSDM), introduced here, are anodic titania nanotube arrays filled with concentrated aqueous salt solutions. Capacitors using TiO₂ based TSDM were found to have dielectric constants at ~0 Hz greater than 10⁷ in all cases, a maximum operating voltage of greater than 2 volts and remarkable energy density that surpasses the highest previously reported for EC capacitors by approximately one order of magnitude. A simple model based on the classic ponderable media model was shown to be largely consistent with data from nine EC type capacitors employing TSDM.

  16. Tube-Super Dielectric Materials: Electrostatic Capacitors with Energy Density Greater than 200 J·cm−3

    Directory of Open Access Journals (Sweden)

    Francisco Javier Quintero Cortes

    2015-09-01

    Full Text Available The construction and performance of a second generation of super dielectric material based electrostatic capacitors (EC, with energy density greater than 200 J·cm−3, which rival the best reported energy density of electric double layer capacitors (EDLC, also known as supercapacitors, are reported. The first generation super dielectric materials (SDM are multi-material mixtures with dielectric constants greater than 1.0 × 105, composed of a porous, electrically insulating powder filled with a polarizable, ion-containing liquid. Second-generation SDMs (TSDM, introduced here, are anodic titania nanotube arrays filled with concentrated aqueous salt solutions. Capacitors using TiO2 based TSDM were found to have dielectric constants at ~0 Hz greater than 107 in all cases, a maximum operating voltage of greater than 2 volts and remarkable energy density that surpasses the highest previously reported for EC capacitors by approximately one order of magnitude. A simple model based on the classic ponderable media model was shown to be largely consistent with data from nine EC type capacitors employing TSDM.

  17. Input-parallel output-parallel (IPOP) three-level (TL) DC/DC converters with minimized capacitor ripple currents

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2016-01-01

    , the component current stresses in the proposed converters are reduced. More significantly, the combination of the proposed IPOP TL circuit structure and the interleaving control strategy can largely reduce the ripple currents on the two input capacitors not only by doubling the frequencies of the ripple...... currents on two input capacitors but also by counteracting part of these ripple currents according to the operation principle of the proposed converters. Therefore, the proposed IPOP TL DC/DC converters with the interleaving control strategy can improve the performances of the converters in increasing...... the lifetimes of the input capacitors and minimizing the sizes of the input capacitors. Finally, the simulation and experimental results are presented to verify the effectiveness and feasibility of the proposed converters combined with the interleaving control strategy....

  18. Chemical modification of graphene aerogels for electrochemical capacitor applications.

    Science.gov (United States)

    Hong, Jin-Yong; Wie, Jeong Jae; Xu, Yu; Park, Ho Seok

    2015-12-14

    Graphene aerogel is a relatively new type of aerogel that is ideal for energy storage applications because of its large surface area, high electrical conductivity and good chemical stability. Also, three dimensional interconnected macropores offer many advantages such as low density, fast ion and mass transfer, and easy access to storage sites. Such features allow graphene aerogels to be intensively applied for electrochemical capacitor applications. Despite the growing interest in graphene aerogel-based electrochemical capacitors, however, the graphene aerogels still suffer from their low capacitive performances and high fragility. Both relatively low capacitance and brittleness of physically crosslinked graphene aerogels remain a critical challenge. Until now, a number of alternative attempts have been devoted to overcome these shortcomings. In this perspective, we summarize the recent research progress towards the development of advanced graphene aerogel-based electrochemical capacitors according to the different approaches (e.g. porosity, composition and structure controls). Then, the recently proposed chemical strategies to improve the capacitive performances and mechanical durability of graphene aerogels for practical applications are highlighted. Finally, the current challenges and perspectives in this emerging material are also discussed.

  19. Reliability-oriented Design of a Cost-effective Active Capacitor

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai

    2017-01-01

    This paper presents the reliability-oriented design of a two-terminal active capacitor proposed recently. The two-terminal active capacitor has the same level of convenience as a passive capacitor with reduced requirement of overall energy storage. In order to fully explore the potential...... of the proposed concept, a comprehensive design procedure is necessary to optimally sizing the key components of the active capacitor in terms of cost and reliability. Moreover, the inherent condition monitoring capability of the active capacitor is discussed by utilizing the existing feedback signals. A 500 W...

  20. The use of abdominal binders to treat over-shunting headaches.

    Science.gov (United States)

    Sklar, Frederick H; Nagy, Laszlo; Robertson, Brian D

    2012-06-01

    Headaches are common in children with shunts. Headaches associated with over-shunting are typically intermittent and tend to occur later in the day. Lying down frequently makes the headaches better. This paper examines the efficacy of using abdominal binders to treat over-shunting headaches. Over an 18-year period, the senior author monitored 1027 children with shunts. Office charts of 483 active patients were retrospectively reviewed to identify those children with headaches and, in particular, those children who were thought to have headaches as a result of over-shunting. Abdominal binders were frequently used to treat children with presumed over-shunting headaches, and these data were analyzed. Of the 483 patients undergoing chart review, 258 (53.4%) had headache. A clinical diagnosis of over-shunting was made in 103 patients (21.3% overall; 39.9% of patients with headache). In 14 patients, the headaches were very mild (1-2 on a 5-point scale) and infrequent (1 or 2 per month), and treatment with an abdominal binder was not thought indicated. Eighty-nine patients were treated with a binder, but 19 were excluded from this retrospective study for noncompliance, interruption of the binder trial, or lack of follow-up. The remaining 70 pediatric patients, who were diagnosed with over-shunting headaches and were treated with abdominal binders, were the subjects of a more detailed retrospective study. Significant headache improvement was observed in 85.8% of patients. On average, the patients wore the binders for approximately 1 month, and headache relief usually persisted even after the binders were discontinued. However, the headaches eventually did recur in many of the patients more than a year later. In these patients, reuse of the abdominal binder was successful in relieving headaches in 78.9%. The abdominal binder is an effective, noninvasive therapy to control over-shunting headaches in most children. This treatment should be tried before any surgery is

  1. Posthemorrhagic Hydrocephalus in Newborns: Clinical Characteristics and Role of Ventriculoperitoneal Shunts

    Directory of Open Access Journals (Sweden)

    Inn-Chi Lee

    2009-02-01

    Conclusion: Patients who were shunt-dependent had worse neurodevelopmental outcomes and greater mortality than those without shunts. The results appeared to depend on how far the hydrocephalus had progressed and on the degree of IVH, but the necessity of VP shunts requires reevaluation before they are implanted.

  2. Dielectric material options for integrated capacitors

    NARCIS (Netherlands)

    Ruhl, G.; Lehnert, W.; Lukosius, M.; Wenger, C.; Baristiran Kaynak, C.; Blomberg, T.; Haukka, S.; Baumann, P.K.; Besling, W.F.A.; Roest, A.L.; Riou, B.; Lhostis, S.; Halimaou, A.; Roozeboom, F.; Langereis, E.; Kessels, W.M.M.; Zauner, A.; Rushworth, S.A.

    2014-01-01

    Future MIM capacitor generations will require significantly increased specific capacitances by utilization of high-k dielectric materials. In order to achieve high capacitance per chip area, these dielectrics have to be deposited in three-dimensional capacitor structures by ALD or AVD (atomic vapor

  3. NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

    Science.gov (United States)

    Sampson, Mike; Brusse, Jay

    2018-01-01

    Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

  4. Gravitational shunt units may cause under-drainage in bedridden patients.

    Science.gov (United States)

    Kaestner, S; Kruschat, T; Nitzsche, N; Deinsberger, W

    2009-03-01

    Implantation of a shunt in a hydrocephalic patient still carries a risk of complications such as over-drainage and under-drainage. Gravitational shunt units are especially designed to minimize the problem of over-drainage. Nevertheless, these valves carry a risk of under-drainage. The best choice of valve for a patient is still challenging. The purpose of this survey was to identify in which patients a gravitational shunt valve is liable to lead to under-drainage. Patients with hydrocephalus entered prospectively into a data base were reviewed retrospectively. The patients were treated between January 2006 to the end of Feb 2007 and those experiencing under- or over-drainage were identified. Thirty-five ventriculo-peritoneal shunt systems were implanted in adult patients. The cause of the hydrocephalus was: normal pressure hydrocephalus in 18 patients, post-haemorrhagic following subarachnoid or intracerebral haemorrhage in 11, associated with a tumour in four and followed a head injury in two patients. Three different valves were used: an adjustable shunt valve with gravitational unit (Pro-GAV 0-20/25 in 21 patients), a gravitational shunt valve with fixed opening pressure (GAV 5/30 in nine patients) and an adjustable differential valve (Hakim medos in five patients). Four patients developed severe, valve-related under-drainage. Each had received a gravitational shunt valve and all were bedridden. In two of these patients it was necessary to change the valve. One patient who had received a differential valve, after regaining mobility developed severe over-drainage with bilateral subdural haematomas. Over-drainage was not seen in long-term bedridden patients with a differential shunt valve. If a bedridden patient with a gravitational shunt valve system lies with a slightly elevated head, this leads to activation of the gravitational unit and this may cause under drainage. As a result, we advise not using an anti-siphon devices in a patient who is bedridden for a

  5. Rough Electrode Creates Excess Capacitance in Thin-Film Capacitors.

    Science.gov (United States)

    Torabi, Solmaz; Cherry, Megan; Duijnstee, Elisabeth A; Le Corre, Vincent M; Qiu, Li; Hummelen, Jan C; Palasantzas, George; Koster, L Jan Anton

    2017-08-16

    The parallel-plate capacitor equation is widely used in contemporary material research for nanoscale applications and nanoelectronics. To apply this equation, flat and smooth electrodes are assumed for a capacitor. This essential assumption is often violated for thin-film capacitors because the formation of nanoscale roughness at the electrode interface is very probable for thin films grown via common deposition methods. In this work, we experimentally and theoretically show that the electrical capacitance of thin-film capacitors with realistic interface roughness is significantly larger than the value predicted by the parallel-plate capacitor equation. The degree of the deviation depends on the strength of the roughness, which is described by three roughness parameters for a self-affine fractal surface. By applying an extended parallel-plate capacitor equation that includes the roughness parameters of the electrode, we are able to calculate the excess capacitance of the electrode with weak roughness. Moreover, we introduce the roughness parameter limits for which the simple parallel-plate capacitor equation is sufficiently accurate for capacitors with one rough electrode. Our results imply that the interface roughness beyond the proposed limits cannot be dismissed unless the independence of the capacitance from the interface roughness is experimentally demonstrated. The practical protocols suggested in our work for the reliable use of the parallel-plate capacitor equation can be applied as general guidelines in various fields of interest.

  6. Valved or valveless ventriculoperitoneal shunting in the treatment of post-haemorrhagic hydrocephalus

    DEFF Research Database (Denmark)

    Andreasen, Trine Hjorslev; Holst, Anders Vedel; Lilja, Alexander

    2016-01-01

    BACKGROUND: Implant infection and obstruction are major complications for ventriculoperitoneal shunts in patients with post-haemorrhagic hydrocephalus. In an effort to (1) reduce the incidence of these complications, (2) reduce the rate of shunt failure and (3) shorten the duration of neurosurgical...... hospitalisation, we have implemented valveless ventriculoperitoneal shunts at our department for adult patients with post-haemorrhagic hydrocephalus and haemorrhagic cerebrospinal fluid at the time of shunt insertion. METHODS: All adult patients (>18 years old) treated for post-haemorrhagic hydrocephalus.......3 %, p = 0.02), but a higher rate of overdrainage (10.3 % vs 2.6 %, p = 0.04). CONCLUSION: The use of a valveless shunting for patients with post-haemorrhagic hydrocephalus results in shorter duration of neurosurgical hospitalisation and lower rate of shunt infection, although these advantages should...

  7. Capacitor energy needed to induce transitions from the superconducting to the normal state

    International Nuclear Information System (INIS)

    Eberhard, P.H.; Ross, R.R.

    1985-08-01

    The purpose of this paper is to describe a technique to turn a long length of superconducting wire normal by dumping a charged capacitor into it and justify some formulae needed in the design. The physical phenomenon is described. A formula for the energy to be stored in the capacitor is given. There are circumstances where the dc in an electrical circuit containing superconducting elements has to be turned off quickly and where the most convenient way to switch the current off is to turn a large portion or all of the superconducting wire normal. Such was the case of the Time Projection Chamber (TPC) superconducting magnet as soon as a quench was detected. The technique used was the discharge of a capacitor into the coil center tap. It turned the magnet winding normal in ten milliseconds or so and provided an adequate quench protection. The technique of discharging a capacitor into a superconducting wire should have many other applications whenever a substantial resistance in a superconducting circuit has to be generated in that kind of time scale. The process involves generating a pulse of large currents in some part of the circuit and heating the wire up by ac losses until the value of the wire critical current is smaller than the dc current. Use of low inductance connections to the circuit is necessary. Then the dc gets turned off due to the resistance of the wire as in a magnet quench

  8. Electrochemical etching of molybdenum for shunt removal in thin film solar cells

    NARCIS (Netherlands)

    Hovestad, A.; Bressers, P.M.M.C.; Meertens, R.M.; Frijters, C.H.; Voorthuijzen, W.P.

    2015-01-01

    High yield and reproducible production is a major challenge in up-scaling thin film Cu(In,Ga)Se2(CIGS) solar cells to large area roll-to-roll industrial manufacturing. Pinholes enabling Ohmic contact between the ZnO:Al front-contact and Mo back contact of the CIGS cell create electrical shunts that

  9. Efficiency Improvement of Capacitor Operation

    Directory of Open Access Journals (Sweden)

    V. P. Kashcheev

    2010-01-01

    Full Text Available A system of modernized capacitor ball-cleaning that prevents formation of depositions on internal capacitor tube surface has been developed in the paper.The system has been introduced at the Minsk TPP-4 (Power Block No.5. The paper presupposes that the economic effect will be nearly 0.43 million US dollars per year at one poer block with turbine Т-250/300-240.

  10. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    Science.gov (United States)

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  11. Application of PFN capacitors in high power systems

    International Nuclear Information System (INIS)

    Parker, R.D.

    1979-01-01

    The application of lightweight reliable capacitors in a mobile energy store is discussed. The relationship of system design parameters to capacitor size and life is displayed. Electric fields and weights of a 21 J/lb and a 77 J/lb pulse discharge capacitor design are given. Estimates of future near-tern development are made

  12. Scoliosis and Syringomyelia With Chiari Malformation After Lumbar Shunting

    Directory of Open Access Journals (Sweden)

    Hsin-Hung Chen

    2010-07-01

    Full Text Available Unsteady gait was noted in a 2-year-old boy with a lumboperitoneal (LP shunt that had been inserted 1 year earlier for increased head circumference caused by communicating hydrocephalus. Scoliosis was also noted during postoperative follow-up. Magnetic resonance imaging revealed new hindbrain tonsillar herniation and an extensive syrinx from C3 to L1. The malfunctioning LP shunt was removed and posterior fossa decompression with ventriculoperitoneal shunt insertion was performed. The unsteady gait recovered completely and scoliosis improved. Magnetic resonance imaging demonstrated resolution of the syrinx and tonsillar herniation. Acquired Chiari I malformation after LP shunt is well documented; usually, patients have no symptoms. This is the first report to have all the cause and effect mechanisms among syringomyelia, scoliosis and Chiari I malformation in 1 patient. We review the literature and discuss the possible mechanisms.

  13. Epidural haematoma: pathophysiological significance of extravasation and arteriovenous shunting

    International Nuclear Information System (INIS)

    Habash, A.H.; Sortland, O.; Zwetnow, N.N.

    1982-01-01

    35 patients with epidural bleeding operated on at Rikshospitalet, Oslo, during the period 1965 - 1980 had preoperative angiography with visualization of the external carotid artery. Twenty-one patients had extravasation of contrast medium from meningeal arteries. Seventeen of the 21 had also shunting of contrast medium from meningeal arteries to meningeal or diploic veins, while 20 of the 21 also had bled from a ruptured meningeal artery at operation. It was further found that of 20 patients who deteriorated after trauma 18 had an epidural arteriovenous shunt or extravasation. Conversely, of 15 patients who improved after trauma 12 had no evidence of a shunt. The strong correlation between the clinical course and the occurrence of extravasation supports previous experimental and clinical data, indicating the epidural arteriovenous shunt to be a major factor in the pathophysiology and the outcome of epidural bleeding. (author)

  14. Shapeable short circuit resistant capacitor

    Science.gov (United States)

    Taylor, Ralph S.; Myers, John D.; Baney, William J.

    2015-10-06

    A ceramic short circuit resistant capacitor that is bendable and/or shapeable to provide a multiple layer capacitor that is extremely compact and amenable to desirable geometries. The capacitor that exhibits a benign failure mode in which a multitude of discrete failure events result in a gradual loss of capacitance. Each event is a localized event in which localized heating causes an adjacent portion of one or both of the electrodes to vaporize, physically cleaning away electrode material from the failure site. A first metal electrode, a second metal electrode, and a ceramic dielectric layer between the electrodes are thin enough to be formed in a serpentine-arrangement with gaps between the first electrode and the second electrode that allow venting of vaporized electrode material in the event of a benign failure.

  15. Energy Efficient Graphene Based High Performance Capacitors.

    Science.gov (United States)

    Bae, Joonwon; Kwon, Oh Seok; Lee, Chang-Soo

    2017-07-10

    Graphene (GRP) is an interesting class of nano-structured electronic materials for various cutting-edge applications. To date, extensive research activities have been performed on the investigation of diverse properties of GRP. The incorporation of this elegant material can be very lucrative in terms of practical applications in energy storage/conversion systems. Among various those systems, high performance electrochemical capacitors (ECs) have become popular due to the recent need for energy efficient and portable devices. Therefore, in this article, the application of GRP for capacitors is described succinctly. In particular, a concise summary on the previous research activities regarding GRP based capacitors is also covered extensively. It was revealed that a lot of secondary materials such as polymers and metal oxides have been introduced to improve the performance. Also, diverse devices have been combined with capacitors for better use. More importantly, recent patents related to the preparation and application of GRP based capacitors are also introduced briefly. This article can provide essential information for future study. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Pressure Effects Analysis of National Ignition Facility Capacitor Module Events

    International Nuclear Information System (INIS)

    Brereton, S; Ma, C; Newton, M; Pastrnak, J; Price, D; Prokosch, D

    1999-01-01

    Capacitors and power conditioning systems required for the National Ignition Facility (NIF) have experienced several catastrophic failures during prototype demonstration. These events generally resulted in explosion, generating a dramatic fireball and energetic shrapnel, and thus may present a threat to the walls of the capacitor bay that houses the capacitor modules. The purpose of this paper is to evaluate the ability of the capacitor bay walls to withstand the overpressure generated by the aforementioned events. Two calculations are described in this paper. The first one was used to estimate the energy release during a fireball event and the second one was used to estimate the pressure in a capacitor module during a capacitor explosion event. Both results were then used to estimate the subsequent overpressure in the capacitor bay where these events occurred. The analysis showed that the expected capacitor bay overpressure was less than the pressure tolerance of the walls. To understand the risk of the above events in NIF, capacitor module failure probabilities were also calculated. This paper concludes with estimates of the probability of single module failure and multi-module failures based on the number of catastrophic failures in the prototype demonstration facility

  17. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Faraj, Walid, E-mail: wf07@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Khalife, Mohammad, E-mail: mk12@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); El-Merhi, Fadi, E-mail: fe19@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Saade, Charbel, E-mail: cs39@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Hallal, Ali, E-mail: ah05@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Haydar, Ali, E-mail: ah24@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon)

    2015-08-15

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications.

  18. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Faraj, Walid; Khalife, Mohammad; Al-Kutoubi, Aghiad; El-Merhi, Fadi; Saade, Charbel; Hallal, Ali; Haydar, Ali

    2015-01-01

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications

  19. Small-Diameter PTFE Portosystemic Shunts: Portocaval vs Mesocaval

    Directory of Open Access Journals (Sweden)

    Robert Shields

    1998-01-01

    Full Text Available Fifty-seven patients with failed sclerotherapy received a mesocaval interposition shunt with an externally supported, ringed polytetrafluoroethylene prosthesis of either 10 or 12 mm diameter. Thirty-one patients had Child-Pugh gradeA disease and 26 grade B; all had a liver volume of 1000– 2500 ml. Follow-up ranged from 16 months to 6 years 3 months. Three patients (5 per cent died in the postoperative period. There were two postoperative recurrences of variceal haemorrhage and one recurrent bleed in the second year after surgery. The cumulative shunt patency rate was 95 per cent and the incidence of encephalopathy 9 per cent; the latter was successfully managed by protein restriction and/or lactulose therapy. The actuarial survival rate for the whole group at 6 years was 78 per cent, for those with Child-Pugh grade A 88 per cent and for grade B 67 per cent. Small-lumen mesocaval interposition shunting achieves portal decompression, preserves hepatopetal flow, has a low incidence of shunt thrombosis, prevents recurrent variceal bleeding and is not associated with significant postoperative encephalopathy.

  20. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.; Cwikiel, Wojciech

    2006-01-01

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to the azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved

  1. SUPER-CAPACITOR APPLICATION IN ELECTRICAL POWER CABLE TESTING FACILITIES IN THERMAL ENDURANCE AND MECHANICAL BRACING TESTS

    Directory of Open Access Journals (Sweden)

    I. V. Oleksyuk

    2015-01-01

    Full Text Available The current-carrying cores of the electrical power cables should be resistant to effects of short-circuit currents whose values depend on the material of the core, its cross-sectional area, cable insulation properties, environment temperature, and the duration of the short-circuit current flow (1 and 3–4 sec. when tested for thermal endurance and mechanical bracing. The facilities for testing the 10 kV aluminum core cables with short-circuit current shall provide mechanical-bracing current 56,82 kA and thermal endurance current 11,16 kA. Although capacitors provide such values of the testing currents to the best advantage, utilizing conventional capacitor-units will involve large expenditures for erecting and  running a separate building. It is expedient to apply super-capacitors qua the electric power supply for testing facilities, as they are capacitors with double-electrical layer and involve the current values of tens of kilo-amperes.The insulation voltage during short-circuit current testing being not-standardized, it is not banned to apply voltages less than 10 kV when performing short-circuit thermal endurance and mechanical bracing tests for electrical power cables of 10 kV. The super-capacitor voltage variation-in-time graph consists of two regions: capacitive and resistive. The capacitive part corresponds to the voltage change consequent on the energy change in the super-capacitors. The resistive part shows the voltage variation due to the active resistance presence in the super-capacitor.The author offers the algorithm determining the number of super capacitors requisite for testing 10 kV-electrical power cables with short-circuit currents for thermal endurance and mechanical bracing. The paper shows that installation of super-capacitors in the facilities testing the cables with short-circuit currents reduces the area needed for the super-capacitors in comparison with conventional capacitors more than by one order of magnitude.

  2. A hybrid filter to mitigate harmonics caused by nonlinear load and resonance caused by power factor correction capacitor

    Science.gov (United States)

    Adan, N. F.; Soomro, D. M.

    2017-01-01

    Power factor correction capacitor (PFCC) is commonly installed in industrial applications for power factor correction (PFC). With the expanding use of non-linear equipment such as ASDs, power converters, etc., power factor (PF) improvement has become difficult due to the presence of harmonics. The resulting capacitive impedance of the PFCC may form a resonant circuit with the source inductive reactance at a certain frequency, which is likely to coincide with one of the harmonic frequency of the load. This condition will trigger large oscillatory currents and voltages that may stress the insulation and cause subsequent damage to the PFCC and equipment connected to the power system (PS). Besides, high PF cannot be achieved due to power distortion. This paper presents the design of a three-phase hybrid filter consisting of a single tuned passive filter (STPF) and shunt active power filter (SAPF) to mitigate harmonics and resonance in the PS through simulation using PSCAD/EMTDC software. SAPF was developed using p-q theory. The hybrid filter has resulted in significant improvement on both total harmonic distortion for voltage (THDV) and total demand distortion for current (TDDI) with maximum values of 2.93% and 9.84% respectively which were within the recommended IEEE 519-2014 standard limits. Regarding PF improvement, the combined filters have achieved PF close to desired PF at 0.95 for firing angle, α values up to 40°.

  3. Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy

    International Nuclear Information System (INIS)

    Sakurabayashi, Shin; Sezai, Shuichi; Yamamoto, Yoshihiro; Hirano, Masanori; Oka, Hiroshi

    1997-01-01

    Purpose. To evaluate the efficacy of embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy (CRHE). Methods. Seven cirrhotic patients with CRHE refractory to medical treatment (3 men and 4 women, mean age 66 years) were studied. Five patients had splenorenal shunts, 1 had a gastrorenal shunt, and 1 had an intrahepatic portal vein-hepatic vein shunt. Shunt embolization was performed using stainless steel coils, with a percutaneous transhepatic portal vein approach in 4 patients and a transrenal vein approach in 3 patients. Results. After embolization, the shunt disappeared in 4 patients on either ultrasound pulsed Doppler monitoring or portography. Complications observed in the 7 patients were fever, transient pleural effusion, ascites, and mild esophageal varices. For 3-6 months after embolization, the 4 patients whose shunts disappeared showed minimal or no reappearance of a shunt, and had no recurrence of encephalopathy. The serum ammonia levels decreased and electroencephalograms also improved. One of the 4 patients, who developed mild esophageal varices, required no treatment. Treatment was effective in 3 of the 4 patients (75%) who underwent embolization via a transhepatic portal vein. Conclusion. Transvascular embolization of shunts improved the outcome in 4 of 7 patients. The most effective embolization was achieved via the percutaneous transhepatic portal vein approach

  4. Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.

    Science.gov (United States)

    Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde

    2016-11-01

    To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.

  5. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  6. Electrochemical capacitor

    Science.gov (United States)

    Anderson, Marc A.; Liu, Kuo -Chuan; Mohr, Charles M.

    1999-10-05

    An inexpensive porous metal oxide material having high surface area, good conductivity and high specific capacitance is advantageously used in an electrochemical capacitor. The materials are formed in a sol-gel process which affords control over the properties of the resultant metal oxide materials.

  7. Switchable capacitor

    NARCIS (Netherlands)

    Rottenberg, Xavier; Jansen, Henricus V.; Tilmans, H.A.C.; Tilmans, Hendrikus; De Raedt, Walter

    2011-01-01

    A micro electromechanical switchable capacitor is disclosed, comprising a substrate, a bottom elecrode, a dielaectric layer deposited on at least part of sai bottum electrode, a conductive floating electrode deposited on at least part of said dielectric layer, an armature positioned proximate to the

  8. Switchable capacitor

    NARCIS (Netherlands)

    Rottenberg, X.; Jansen, Henricus V.; Tilmans, H.A.C.; De Raedt, W.

    2003-01-01

    A micro electromechanical switchable capacitor is disclosed, comprising a substrate, a bottom elecrode, a dielaectric layer deposited on at least part of sai bottum electrode, a conductive floating electrode deposited on at least part of said dielectric layer, an armature positioned proximate to the

  9. Humidity Testing of PME and BME Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander A.; Herzberger, Jaemi

    2014-01-01

    Cracks in ceramic capacitors are one of the major causes of failures during operation of electronic systems. Humidity testing has been successfully used for many years to verify the absence of cracks and assure quality of military grade capacitors. Traditionally, only precious metal electrode (PME) capacitors were used in high reliability applications and the existing requirements for humidity testing were developed for this type of parts. With the advance of base metal electrode (BME) capacitors, there is a need for assessment of the applicability of the existing techniques for the new technology capacitors. In this work, variety of different PME and BME capacitors with introduced cracks were tested in humid environments at different voltages and temperatures. Analysis of the test results indicates differences in the behavior and failure mechanisms for BME and PME capacitors and the need for different testing conditions.

  10. Reliability Evaluation of Power Capacitors in a Wind Turbine System

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede

    2018-01-01

    With the increasing penetration of wind power, reliable and cost-effective wind energy production is of more and more importance. The doubly-fed induction generator based partial-scale wind power converter is still dominating in the existing wind farms. In this paper, the reliability assessment...... block diagram is used to bridge the gap between the Weibull distribution based component-level individual capacitor and the capacitor bank. A case study of a 2 MW wind power converter shows that the lifetime is significantly reduced from the individual capacitor to the capacitor bank. Besides, the dc...... of power capacitors is studied considering the annual mission profile. According to an electro-thermal stress evaluation, the time-to-failure distribution of both the dc-link capacitor and ac-side filter capacitor is detailed investigated. Aiming for the systemlevel reliability analysis, a reliability...

  11. Migration of the peritoneal catheter of a ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Ventricular shunt is a well-established modality in the management of hydrocephalus. However, it can be associated with numerous complications and disastrous consequences. The reported incidence of intra-abdominal complications in infants and children after ventriculoperitoneal (VP) shunt procedures is about 24% ...

  12. Fast risetime one megajoule capacitor bank

    International Nuclear Information System (INIS)

    Markins, D.; Baker, W.L.; Reinovsky, R.E.; Clark, J.G.

    1976-01-01

    A 100 kV, 1.1 MJ capacitor bank for plasma research experiments has been constructed for the Air Force Weapons Laboratory. The system consists of twenty, individual, low inductance capacitor modules, each utilizing a four element switch package approximately 2 meters wide. Each module contains twenty-four ''scyllac'' type 1.85 μF capacitors. A 100 kV output pulse is obtained by charging the top half of each module to +50 kV and the bottom half to -50 kV. A pressurized, low inductance multichannel switch package incorporating four separately triggered elements is designed to fit into the parallel plate transmission line system of the capacitor module. The bank is configured in a cross shape with twenty modules spaced uniformly around the perimeter of a parallel plate transmission line. The transmission line is constructed with 32 mil aluminum and insulated with 60 mils of mylar. The bank is designed to feed an easily replaceable central coaxial load. The entire system has been repeatedly fired at 100 kV with a dummy resistive load and has delivered 2.2 x 10 7 amperes of current with a risetime of 1.1 μsec. The total measured system inductance is 2.2 nH. This system represents a significant advance in the development of reliable, fast, high current capacitor banks

  13. A 800 kV compact peaking capacitor for nanosecond generator.

    Science.gov (United States)

    Jia, Wei; Chen, Zhiqiang; Tang, Junping; Chen, Weiqing; Guo, Fan; Sun, Fengrong; Li, Junna; Qiu, Aici

    2014-09-01

    An extremely compact high voltage peaking capacitor is developed. The capacitor has a pancake structure with a diameter of 315 mm, a thickness of 59 mm, and a mass of 6.1 kg. The novel structural design endows the capacitor with a better mechanical stability and reliability under hundreds of kilovolts pulse voltage and an inner gas pressure of more than 1.5 MPa. The theoretical value of the capacitor self-inductance is near to 17 nH. Proved by series of electrical experiments, the capacitor can endure a high-voltage pulse with a rise time of about 20 ns, a half-width duration of around 25 ns, and an amplitude of up to 800 kV in a single shot model. When the capacitor was used in an electromagnetic pulse simulator as a peaking capacitor, the rise time of the voltage pulse can be reduced from 20 ns to less than 3 ns. The practical value of the capacitor's inductance deduced from the experimental date is no more than 25 nH.

  14. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  15. A Power-Efficient Wireless Capacitor Charging System Through an Inductive Link.

    Science.gov (United States)

    Lee, Hyung-Min; Ghovanloo, Maysam

    2013-10-01

    A power-efficient wireless capacitor charging system for inductively powered applications has been presented. A bank of capacitors can be directly charged from an ac source by generating a current through a series charge injection capacitor and a capacitor charger circuit. The fixed charging current reduces energy loss in switches, while maximizing the charging efficiency. An adaptive capacitor tuner compensates for the resonant capacitance variations during charging to keep the amplitude of the ac input voltage at its peak. We have fabricated the capacitor charging system prototype in a 0.35- μ m 4-metal 2-poly standard CMOS process in 2.1 mm 2 of chip area. It can charge four pairs of capacitors sequentially. While receiving 2.7-V peak ac input through a 2-MHz inductive link, the capacitor charging system can charge each pair of 1 μ F capacitors up to ±2 V in 420 μ s, achieving a high measured charging efficiency of 82%.

  16. Development of High Temperature Capacitor Technology and Manufacturing Capability

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2011-05-15

    The goal of the Development of High Temperature Capacitor Technology and Manufacturing Capability program was to mature a production-ready supply chain for reliable 250°C FPE (fluorinated polyester) film capacitors by 2011. These high-temperature film capacitors enable both the down hole drilling and aerospace industries by enabling a variety of benefits including: - Deeper oil exploration in higher temperature and pressure environments - Enabling power electronic and control equipment to operate in higher temperature environments - Enabling reduced cooling requirements of electronics - Increasing reliability and life of capacitors operating below rated temperature - Enabling capacitors to handle higher electrical losses without overheating. The key challenges to bringing the FPE film capacitors to market have been manufacturing challenges including: - FPE Film is difficult to handle and wind, resulting in poor yields - Voltage breakdown strength decreases when the film is wound into capacitors (~70% decrease) - Encapsulation technologies must be improved to enable higher perature operation - Manufacturing and test cycle time is very long As a direct result of this program most of the manufacturing challenges have been met. The FPE film production metalization and winding yield has increased to over 82% from 70%, and the voltage breakdown strength of the wound capacitors has increased 270% to 189 V/μm. The high temperature packaging concepts are showing significant progress including promising results for lead attachments and hermetic packages at 200°C and non-hermetic packages at 250°C. Manufacturing and test cycle time will decrease as the market for FPE capacitors develops.

  17. Rudhe syndrome: reversible right middle lobe emphysema in infants with left-to-right shunts - an historical review

    International Nuclear Information System (INIS)

    Collins, Lee K.; Levin, Terry L.; Berdon, Walter E.; Cowles, Robert A.; Newman, Beverley

    2010-01-01

    In 1971, the Swedish radiologist Ulf Rudhe wrote a provocative paper on right middle lobe emphysema in infants with left-to-right shunts in which he suggested cardiac surgery rather than lung resection. At the time, this was counter to accepted medical practice. Earlier diagnosis and better medical management of ventricular septal defect in infants has proved Rudhe correct. However, two current cases of large left-to-right shunts in infants with emphysema of the right middle lobe prompt this historical review of what seemed a closed-episode in pediatric cardiac surgery. (orig.)

  18. Switched-capacitor multiply-by-two amplifier with reduced capacitor mismatches sensitivity and full swing sample signal common-mode voltage

    International Nuclear Information System (INIS)

    Xu Xinnan; Yao Suying; Xu Jiangtao; Nie Kaiming

    2012-01-01

    A switched-capacitor amplifier with an accurate gain of two that is insensitive to component mismatch is proposed. This structure is based on associating two sets of two capacitors in cross series during the amplification phase. This circuit permits the common-mode voltage of the sample signal to reach full swing. Using the charge-complement technique, the proposed amplifier can reduce the impact of parasitic capacitors on the gain accuracy effectively. Simulation results show that as sample signal common-mode voltage changes, the difference between the minimum and maximum gain error is less than 0.03%. When the capacitor mismatch is increased from 0 to 0.2%, the gain error is deteriorated by 0.00015%. In all simulations, the gain of amplifier is 69 dB. (semiconductor integrated circuits)

  19. What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?

    Science.gov (United States)

    Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon

    2014-10-01

    Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.

  20. Numerical and experimental studies of stack shunt current for vanadium redox flow battery

    International Nuclear Information System (INIS)

    Yin, Cong; Guo, Shaoyun; Fang, Honglin; Liu, Jiayi; Li, Yang; Tang, Hao

    2015-01-01

    Highlights: • A coupled three-dimensional model of VRB cell stack is developed. • Shunt current of the stack is studied with the model and experiment. • Increased electrolyte resistance in channel and manifold lowers the shunt current. • Shunt current loss increases with stack cell number nonlinearly. - Abstract: The stack shunt current of VRB (vanadium redox flow battery) was investigated with experiments and 3D (three-dimensional) simulations. In the proposed model, cell voltages and electrolyte conductivities were calculated based on electrochemical reaction distributions and SOC (state of charge) values, respectively, while coulombic loss was estimated according to shunt current and vanadium ionic crossover through membrane. Shunt current distributions and coulombic efficiency are analyzed in terms of electrolyte conductivities and stack cell numbers. The distributions of cell voltages and shunt currents calculated with proposed model are validated with single cell and short stack tests. The model can be used to optimize VRB stack manifold and channel designs to improve VRB system efficiency

  1. PLZT capacitor on glass substrate

    Science.gov (United States)

    Fairchild, M. Ray; Taylor, Ralph S.; Berlin, Carl W.; Wong, Celine W. K.; Ma, Beihai; Balachandran, Uthamalingam

    2016-01-05

    A lead-lanthanum-zirconium-titanate (PLZT) capacitor on a substrate formed of glass. The first metallization layer is deposited on a top side of the substrate to form a first electrode. The dielectric layer of PLZT is deposited over the first metallization layer. The second metallization layer deposited over the dielectric layer to form a second electrode. The glass substrate is advantageous as glass is compatible with an annealing process used to form the capacitor.

  2. Prophylactic antibiotics in pediatric shunt surgery.

    Science.gov (United States)

    Biyani, N; Grisaru-Soen, G; Steinbok, P; Sgouros, S; Constantini, S

    2006-11-01

    The optimal antibiotic prophylaxis for pediatric shunt-related procedures is not clear. There is much inconsistency among different medical centers. This paper summarizes and analyzes the various prophylactic antibiotic regiments used for shunt-related surgeries at different pediatric neurosurgery centers in the world. A survey questionnaire was distributed through the Pediatric Neurosurgery list-server (an e-mail-based special interest group in pediatric neurosurgery). Forty-five completed questionnaires were received, one per medical center, primarily from pediatric neurosurgeons with the following geographic breakdown: 25 from North America, 13 from Europe, and 7 from Asia and other countries. All centers routinely administered prophylactic antibiotics for shunt-related procedures. The drugs of choice were first-generation cephalosporins (23), second-generation cephalosporins (10), naficillin/oxacillin (4), vancomycin (3), clindamycin (1), amoxicillin (1), and mixed protocols in three centers. The initial drug administration ("first dose") was: in the department before transfer to operating room (5), upon arrival to operating room (11), at induction of anesthesia (13), and at initial skin incision (16). The duration of antibiotic dosage also varied: single dose (13), 24-h administration (26), 48-h administration (2), and longer than 48 h in four centers. Two general tendencies were noted, common to the majority of participating centers. There was a general trend to modify antibiotic treatment protocol in "high-risk" populations. The second common theme noted in more than half of responding centers was the use of long-term antibiotic treatment for externalized devices (such as externalized shunts, external ventricular drains or lumbar drains), usually till the device was in place.

  3. Multi-resonant electromagnetic shunt in base isolation for vibration damping and energy harvesting

    Science.gov (United States)

    Pei, Yalu; Liu, Yilun; Zuo, Lei

    2018-06-01

    This paper investigates multi-resonant electromagnetic shunts applied to base isolation for dual-function vibration damping and energy harvesting. Two multi-mode shunt circuit configurations, namely parallel and series, are proposed and optimized based on the H2 criteria. The root-mean-square (RMS) value of the relative displacement between the base and the primary structure is minimized. Practically, this will improve the safety of base-isolated buildings subjected the broad bandwidth ground acceleration. Case studies of a base-isolated building are conducted in both the frequency and time domains to investigate the effectiveness of multi-resonant electromagnetic shunts under recorded earthquake signals. It shows that both multi-mode shunt circuits outperform traditional single mode shunt circuits by suppressing the first and the second vibration modes simultaneously. Moreover, for the same stiffness ratio, the parallel shunt circuit is more effective at harvesting energy and suppressing vibration, and can more robustly handle parameter mistuning than the series shunt circuit. Furthermore, this paper discusses experimental validation of the effectiveness of multi-resonant electromagnetic shunts for vibration damping and energy harvesting on a scaled-down base isolation system.

  4. Capacitance of carbon-based electrical double-layer capacitors.

    Science.gov (United States)

    Ji, Hengxing; Zhao, Xin; Qiao, Zhenhua; Jung, Jeil; Zhu, Yanwu; Lu, Yalin; Zhang, Li Li; MacDonald, Allan H; Ruoff, Rodney S

    2014-01-01

    Experimental electrical double-layer capacitances of porous carbon electrodes fall below ideal values, thus limiting the practical energy densities of carbon-based electrical double-layer capacitors. Here we investigate the origin of this behaviour by measuring the electrical double-layer capacitance in one to five-layer graphene. We find that the capacitances are suppressed near neutrality, and are anomalously enhanced for thicknesses below a few layers. We attribute the first effect to quantum capacitance effects near the point of zero charge, and the second to correlations between electrons in the graphene sheet and ions in the electrolyte. The large capacitance values imply gravimetric energy storage densities in the single-layer graphene limit that are comparable to those of batteries. We anticipate that these results shed light on developing new theoretical models in understanding the electrical double-layer capacitance of carbon electrodes, and on opening up new strategies for improving the energy density of carbon-based capacitors.

  5. BioCapacitor: A novel principle for biosensors.

    Science.gov (United States)

    Sode, Koji; Yamazaki, Tomohiko; Lee, Inyoung; Hanashi, Takuya; Tsugawa, Wakako

    2016-02-15

    Studies regarding biofuel cells utilizing biocatalysts such as enzymes and microorganisms as electrocatalysts have been vigorously conducted over the last two decades. Because of their environmental safety and sustainability, biofuel cells are expected to be used as clean power generators. Among several principles of biofuel cells, enzyme fuel cells have attracted significant attention for their use as alternative energy sources for future implantable devices, such as implantable insulin pumps and glucose sensors in artificial pancreas and pacemakers. However, the inherent issue of the biofuel cell principle is the low power of a single biofuel cell. The theoretical voltage of biofuel cells is limited by the redox potential of cofactors and/or mediators employed in the anode and cathode, which are inadequate for operating any devices used for biomedical application. These limitations inspired us to develop a novel biodevice based on an enzyme fuel cell that generates sufficient stable power to operate electric devices, designated "BioCapacitor." To increase voltage, the enzyme fuel cell is connected to a charge pump. To obtain a sufficient power and voltage to operate an electric device, a capacitor is used to store the potential generated by the charge pump. Using the combination of a charge pump and capacitor with an enzyme fuel cell, high voltages with sufficient temporary currents to operate an electric device were generated without changing the design and construction of the enzyme fuel cell. In this review, the BioCapacitor principle is described. The three different representative categories of biodevices employing the BioCapacitor principle are introduced. Further, the recent challenges in the developments of self-powered stand-alone biodevices employing enzyme fuel cells combined with charge pumps and capacitors are introduced. Finally, the future prospects of biodevices employing the BioCapacitor principle are addressed. Copyright © 2015 The Authors

  6. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    International Nuclear Information System (INIS)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-01-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinima and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterioportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture. (author)

  7. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-11-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinoma and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterooportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture.

  8. Splenophrenic portosystemic shunt in dogs with and without portal ...

    African Journals Online (AJOL)

    The possible existence of the same pattern of porto-caval connection in dogs having a single congenital portosystemic shunt (CPSS) and in dogs having multiple acquired portosystemic shunt (MAPSS) secondary to portal hypertension (PH) was evaluated. Retrospective evaluation of all CT examinations of patients having ...

  9. Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.

    Science.gov (United States)

    Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K

    2015-03-01

    We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Symptomatic spinal cord deformity secondary to a redundant intramedullary shunt catheter

    International Nuclear Information System (INIS)

    Quencer, R.M.; Montalvo Morse, B.M.; Green, B.A.; Eismont, F.J.

    1985-01-01

    Right arm pain, motor and sensory loss in the right arm and right facial numbness recurred in a 27 year old quadraplegic shortly after a posttraumatic spinal cord cyst (PTSCC) was shunted via a catheter into the adjacent subarachnoid space. Although shunt malfunction was clinically suspected, metrizamide computed tomography (MCT) suggested that redundancy of the catheter had caused deformity of the spinal cord. This hypothesis was confirmed at surgery when intraoperative spinal sonography (IOSS) showed that the spinal cord deformity at C 1 -C 2 disappeared when the catheter was withdrawn. This case shows that new or recurrent spinal cord symptoms may be due to a mechanical deformity of the cord rather than shunt malfunction, that restricting the length of the shunt catheter which is used to decompress PTSCCs is important, and that IOSS is an indispensible tool for visualizing the changes in spinal cord morphology during shunting procedures. (orig.)

  11. Design and Characterization of Vertical Mesh Capacitors in Standard CMOS

    DEFF Research Database (Denmark)

    Christensen, Kåre Tais

    2001-01-01

    This paper shows how good RF capacitors can be made in a standard digital CMOS process. The capacitors which are also well suited for binary weighted switched capacitor banks show very good RF performance: Q-values of 57 at 4.0 GHz, a density of 0.27 fF/μ2, 2.2 μm wide shielded unit capacitors, 6...

  12. Leakage Currents in Low-Voltage PME and BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2015-01-01

    Introduction of BME capacitors to high-reliability electronics as a replacement for PME capacitors requires better understanding of changes in performance and reliability of MLCCs to set justified screening and qualification requirements. In this work, absorption and leakage currents in various lots of commercial and military grade X7R MLCCs rated to 100V and less have been measured to reveal difference in behavior of PME and BME capacitors in a wide range of voltages and temperatures. Degradation of leakage currents and failures in virgin capacitors and capacitors with introduced cracks has been studied at different voltages and temperatures during step stress highly accelerated life testing. Mechanisms of charge absorption, conduction and degradation have been discussed and a failure model in capacitors with defects suggested.

  13. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    Energy Technology Data Exchange (ETDEWEB)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Atar, Eli; Schwartz, Michael [Schneider Children' s Medical Center Israel, Section of Radiology (Israel); Kachko, Ludmila [Schneider Children' s Medical Center Israel, Section of Anesthesiology (Israel); Superina, Riccardo; Amir, Gabriel [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Shapiro, Rivka [Schneider Children' s Medical Center Israel, Section of Gastroenterology (Israel); Birk, Einat [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel)

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  14. Simple Ways to Make Real Capacitors

    Science.gov (United States)

    Herman, Rhett

    2014-01-01

    Many of us have grabbed two pieces of aluminum foil and a paper towel, quickly sandwiched them together, and exclaimed in lecture, "Look! It's easy to make a capacitor!" Then we move on from there, calculating things such as capacitances with various dielectrics or plate sizes, the capacitance of capacitor networks, RC circuits,…

  15. Cellulose Triacetate Dielectric Films For Capacitors

    Science.gov (United States)

    Yen, Shiao-Ping S.; Jow, T. Richard

    1994-01-01

    Cellulose triacetate investigated for use as dielectric material in high-energy-density capacitors for pulsed-electrical-power systems. Films of cellulose triacetate metalized on one or both sides for use as substrates for electrodes and/or as dielectrics between electrodes in capacitors. Used without metalization as simple dielectric films. Advantages include high breakdown strength and self-healing capability.

  16. Modelling of storage of the photovoltaic energy by super-capacitors

    International Nuclear Information System (INIS)

    Camara, Mohamed Ansoumane

    2011-01-01

    The storage by ultra-capacitors of photovoltaic energy is modeled in order to have an accurate and accessible model to integrate ultra-capacitors into solar energy conversion systems. Ultra-capacitors are modeled by a multi-branch circuit representation composed of resistors and capacitors with variable voltage whose values are determined by an accurate characterization experiment. Moreover, all the elements of a typical photovoltaic energy conversion system are modeled by using the Matlab/Simulink software (solar radiation, photovoltaic arrays, regulator, batteries and charges). The energy storage model by ultra-capacitors is then validated by the good agreement of measured values taken in real conditions with the results provided by simulations. Finally, two examples are proposed and discussed: the determination of the storage duration of ultra-capacitors versus solar irradiance and ambient temperature, and the integration of ultra-capacitors in the electrical feeding system of a DC motor to reduce the electrical current peak of the battery at the start of the motor. (author) [fr

  17. Reliability of capacitors for DC-link applications - An overview

    DEFF Research Database (Denmark)

    Wang, Huai; Blaabjerg, Frede

    2013-01-01

    DC-link capacitors are an important part in the majority of power electronic converters which contribute to cost, size and failure rate on a considerable scale. From capacitor users' viewpoint, this paper presents a review on the improvement of reliability of DC-link in power electronic converters...... from two aspects: 1) reliability-oriented DC-link design solutions; 2) conditioning monitoring of DC-link capacitors during operation. Failure mechanisms, failure modes and lifetime models of capacitors suitable for the applications are also discussed as a basis to understand the physics......-of-failure. This review serves to provide a clear picture of the state-of-the-art research in this area and to identify the corresponding challenges and future research directions for capacitors and their DC-link applications....

  18. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  19. Two-Capacitor Problem: A More Realistic View.

    Science.gov (United States)

    Powell, R. A.

    1979-01-01

    Discusses the two-capacitor problem by considering the self-inductance of the circuit used and by determining how well the usual series RC circuit approximates the two-capacitor problem when realistic values of L, C, and R are chosen. (GA)

  20. Fully inkjet printed RF inductors and capacitors using polymer dielectric and silver conductive ink with through vias

    KAUST Repository

    McKerricher, Garret

    2015-03-01

    In this paper, fully inkjet printed multilayer capacitors and inductors are fabricated and characterized using poly 4-vinylphenol (PVP) ink as the dielectric layer and silver nanoparticle ink as the conductor. Inkjet printed through vias, created with a novel dissolving method are used to make RF structures in a multilayer inkjet printing process. The vias have been realized in a 350-nm PVP film and exhibit resistance better than 0.1 Ω. Spiral inductors from 10 to 75 nH have been realized with maximum quality factors around five. The 10-nH inductor exhibits a self-resonant frequency slightly below 1 GHz. Metal-insulator-metal capacitors are realized with densities of 50 pF/mm-2. These capacitors demonstrate values ranging from 16 to 50 pF. The 16-pF capacitor shows a self-resonant frequency over 1.5 GHz. The successful implementation of inductors and capacitors in an all inkjet printed multilayer process with vias is an important step toward fully inkjet-printed large area and flexible RF systems.

  1. Fully inkjet printed RF inductors and capacitors using polymer dielectric and silver conductive ink with through vias

    KAUST Repository

    McKerricher, Garret; Gonzalez Perez, Jose; Shamim, Atif

    2015-01-01

    In this paper, fully inkjet printed multilayer capacitors and inductors are fabricated and characterized using poly 4-vinylphenol (PVP) ink as the dielectric layer and silver nanoparticle ink as the conductor. Inkjet printed through vias, created with a novel dissolving method are used to make RF structures in a multilayer inkjet printing process. The vias have been realized in a 350-nm PVP film and exhibit resistance better than 0.1 Ω. Spiral inductors from 10 to 75 nH have been realized with maximum quality factors around five. The 10-nH inductor exhibits a self-resonant frequency slightly below 1 GHz. Metal-insulator-metal capacitors are realized with densities of 50 pF/mm-2. These capacitors demonstrate values ranging from 16 to 50 pF. The 16-pF capacitor shows a self-resonant frequency over 1.5 GHz. The successful implementation of inductors and capacitors in an all inkjet printed multilayer process with vias is an important step toward fully inkjet-printed large area and flexible RF systems.

  2. Shunt impedance measurement of the APS BBC injector

    International Nuclear Information System (INIS)

    Sun, Y.E.; Lewellen, J.W.

    2006-01-01

    The injector test stand (ITS) at Advanced Photon Source (APS) presently incorporates a ballistic bunch compression (BBC) gun, and it is used as a beam source for a number of experiments, including THz generation, beam position monitor testing for the Linac Coherent Light Source (LCLS), novel cathode testing, and radiation therapy source development. The BBC gun uses three independently powered and phased rf cavities, one cathode cell, and two full cells to provide beam energies from 2 to 10 MeV with variable energy spread, energy chirp, and, to an extent, bunch duration. The shunt impedance of an rf accelerator determines how effectively the accelerator can convert supplied rf power to accelerating gradient. The calculation of the shunt impedance can be complicated if the beam energy changes substantially during its transit through a cavity, such as in a cathode cell. We present the results of direct measurements of the shunt impedance of the APS BBC gun on an individual cavity basis, including the cathode cell, and report on achieved gradients. We also present a comparison of the measured shunt impedance with theoretical values calculated from the rf models of the cavities.

  3. Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-01-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  4. Experimental comparison of piezoelectric and magnetostrictive shunt dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-04-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (`piezoceramic') and PMN-30%PT (`single crystal') stacks, as well as a Tb0.3Dy0.7Fe1.92 (`Terfenol-D') rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  5. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  6. Transluminal angioplasty of a stenotic surgical splenorenal shunt

    International Nuclear Information System (INIS)

    Beers, B. van; Roche, A.; Cauquil, P.

    1988-01-01

    A stenosis of a side-to-side splenorenal shunt was treated by percutaneous angioplasty two years after the performance of the shunt. After dilatation, there was a fall of the splenorenal pressure gradient from 28 to 17 cm H 2 O and good transanastomotic flow was re-estabilshed. As in other arterial and venous territories, angioplasty may be an interesting alternative to surgery. (orig.)

  7. Physics Based Modeling and Prognostics of Electrolytic Capacitors

    Science.gov (United States)

    Kulkarni, Chetan; Ceyla, Jose R.; Biswas, Gautam; Goebel, Kai

    2012-01-01

    This paper proposes first principles based modeling and prognostics approach for electrolytic capacitors. Electrolytic capacitors have become critical components in electronics systems in aeronautics and other domains. Degradations and faults in DC-DC converter unit propagates to the GPS and navigation subsystems and affects the overall solution. Capacitors and MOSFETs are the two major components, which cause degradations and failures in DC-DC converters. This type of capacitors are known for its low reliability and frequent breakdown on critical systems like power supplies of avionics equipment and electrical drivers of electromechanical actuators of control surfaces. Some of the more prevalent fault effects, such as a ripple voltage surge at the power supply output can cause glitches in the GPS position and velocity output, and this, in turn, if not corrected will propagate and distort the navigation solution. In this work, we study the effects of accelerated aging due to thermal stress on different sets of capacitors under different conditions. Our focus is on deriving first principles degradation models for thermal stress conditions. Data collected from simultaneous experiments are used to validate the desired models. Our overall goal is to derive accurate models of capacitor degradation, and use them to predict performance changes in DC-DC converters.

  8. A Humidity-Dependent Lifetime Derating Factor for DC Film Capacitors

    DEFF Research Database (Denmark)

    Wang, Huai; Reigosa, Paula Diaz; Blaabjerg, Frede

    2015-01-01

    accelerated testing of film capacitors under different humidity conditions, enabling a more justified lifetime prediction of film capacitors for DC-link applications under specific climatic environments. The analysis of the testing results and the detailed discussion on the derating factor with different......Film capacitors are widely assumed to have superior reliability performance than Aluminum electrolytic capacitors in DC-link design of power electronic converters. However, the assumption needs to be critically judged especially for applications under high humidity environments. This paper proposes...... a humidity-dependent lifetime derating factor for a type of plastic-boxed metallized DC film capacitors. It overcomes the limitation that the humidity impact is not considered in the state-of-the-art DC film capacitor lifetime models. The lifetime derating factor is obtained based on a total of 8,700 hours...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  10. Surgical approach for systemic-pulmonary shunt in neonates with functionally univentricular heart: comparison between sternotomy and thoracotomy.

    Science.gov (United States)

    Sasaki, Takashi; Takeda, Yuko; Ohnakatomi, Yasuko; Asou, Toshihide

    2016-09-01

    The preferred surgical approach for systemic-pulmonary shunts has changed from thoracotomy to sternotomy in our institution, to concomitantly manage the ductus arteriosus during surgery. The purpose of this study was to compare the outcomes of systemic-pulmonary shunts for neonates with functionally univentricular hearts based on surgical approach. Fifty-two neonates with functionally univentricular hearts underwent systemic-pulmonary shunt via sternotomy (n = 28) or thoracotomy (n = 24). Patient characteristics, achievement rates of right heart bypass, and survival rates were compared for the different approaches. Prenatal diagnosis was made more common in the sternotomy group (p = 0.006). The shunt was placed more centrally in the sternotomy group. The ductus arteriosus was ligated or banded in most patients in the sternotomy group (26/28) and in a few patients in the thoracotomy group (6/24). Frequency of ductal management in the early postoperative phase was not different between the groups (21 vs 25 %), but three new incisions had to be made in the thoracotomy group. No differences were seen in the achievement rates of bidirectional cavopulmonary shunts (86 vs 87 % at 10 months of age) and total cavopulmonary connection (81 vs 81 % at 2 years of age), or in the survival rates (92 vs 96 % at 8 years). There were no differences in short- and long-term outcomes between the groups. The sternotomy approach might be preferable in the current era of prenatal diagnosis, to allow simultaneous duct management during systemic-pulmonary shunt surgery, particularly in patients with large ducts associated with functionally univentricular hearts.

  11. MOSFET and MOS capacitor responses to ionizing radiation

    Science.gov (United States)

    Benedetto, J. M.; Boesch, H. E., Jr.

    1984-01-01

    The ionizing radiation responses of metal oxide semiconductor (MOS) field-effect transistors (FETs) and MOS capacitors are compared. It is shown that the radiation-induced threshold voltage shift correlates closely with the shift in the MOS capacitor inversion voltage. The radiation-induced interface-state density of the MOSFETs and MOS capacitors was determined by several techniques. It is shown that the presence of 'slow' states can interfere with the interface-state measurements.

  12. Shunted-Josephson-junction model. II. The nonautonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model with a monochromatic ac current drive is discussed employing the qualitative methods of the theory of nonlinear oscillations. As in the preceding paper dealing with the autonomous junction, the model includes a phase-dependent conductance and a shunt capacitance....... The mathematical discussion makes use of the phase-space representation of the solutions to the differential equation. The behavior of the trajectories in phase space is described for different characteristic regions in parameter space and the associated features of the junction IV curve to be expected are pointed...... out. The main objective is to provide a qualitative understanding of the junction behavior, to clarify which kinds of properties may be derived from the shunted-junction model, and to specify the relative arrangement of the important domains in the parameter-space decomposition....

  13. Pseudo-capacitor device for aqueous electrolytes

    Science.gov (United States)

    Prakash, Jai; Thackeray, Michael M.; Dees, Dennis W.; Vissers, Donald R.; Myles, Kevin M.

    1998-01-01

    A pseudo-capacitor having a high energy storage capacity develops a double layer capacitance as well as a Faradaic or battery-like redox reaction, also referred to as pseudo-capacitance. The Faradaic reaction gives rise to a capacitance much greater than that of the typical ruthenate oxide ultracapacitor which develops only charge separation-based double layer capacitance. The capacitor employs a lead and/or bismuth/ruthenate and/or iridium system having the formula A.sub.2 ›B.sub.2-x Pb.sub.x !O.sub.7-y, where A=Pb, Bi, and B=Ru, Ir, and Ocapacitor. The amount of expensive ruthenate and iridium can be substantially reduced in the pseudo-capacitor by increasing the lead content while improving energy storage capacity.

  14. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    International Nuclear Information System (INIS)

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-01-01

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ∼50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5–13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2–8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia

  15. Conversion of Low-Flow Priapism to High-Flow State Using T-Shunt with Tunneling.

    Science.gov (United States)

    Mistry, Neil A; Tadros, Nicholas N; Hedges, Jason C

    2017-01-01

    Introduction . The three types of priapism are stuttering, arterial (high-flow, nonischemic), and venoocclusive (low-flow, ischemic). These are usually distinct entities and rarely occur in the same patient. T-shunts and other distal shunts are frequently combined with tunneling, but a seldom recognized potential complication is conversion to a high-flow state. Case Presentation . We describe 2 cases of men who presented with low-flow priapism episodes that were treated using T-shunts with tunneling that resulted with both men having recurrent erections shortly after surgery that were found to be consistent with high-flow states. Case 1 was a 33-year-old male with sickle cell anemia and case 2 was a 24-year-old male with idiopathic thrombocytopenic purpura. In both cases the men were observed over several weeks and both men returned to normal erectile function. Conclusions . Historically, proximal shunts were performed only in cases when distal shunts failed and carry a higher risk of serious complications. T-shunts and other distal shunts combined with tunneling are being used more frequently in place of proximal shunts. These cases illustrate how postoperative erections after T-shunts with tunneling can signify a conversion from low-flow to high-flow states and could potentially be misdiagnosed as an operative failure.

  16. Radiation effects in polycarbonate capacitors

    Directory of Open Access Journals (Sweden)

    Vujisić Miloš

    2009-01-01

    Full Text Available The aim of this paper is to examine the influence of neutron and gamma irradiation on the dissipation factor and capacitance of capacitors with polycarbonate dielectrics. The operation of capacitors subject to extreme conditions, such as the presence of ionizing radiation fields, is of special concern in military industry and space technology. Results obtained show that the exposure to a mixed neutron and gamma radiation field causes a decrease of capacitance, while the loss tangent remains unchanged.

  17. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  18. Fabrication of wound capacitors using flexible alkali-free glass

    International Nuclear Information System (INIS)

    Wilke, Rudeger H. T.; Baker, Amanda; Brown-Shaklee, Harlan; Johnson-Wilke, Raegan; Hettler, Chad

    2016-01-01

    Here, alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance of 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.

  19. Brain abscesses associated with right-to-left shunts in adults.

    Science.gov (United States)

    Memon, Kashif A; Cleveland, Kerry O; Gelfand, Michael S

    2012-04-01

    Although brain abscesses are frequently cryptogenic in origin, bacteria must reach the brain either by direct or hematogenous spread. Right-to-left shunts, caused either by intrapulmonary vascular malformations or congenital heart defects, may allow microorganisms to evade the normal host defenses in the lungs and lead to development of brain abscesses. Two patients recently presented with brain abscesses and were found to have conditions associated with right-to-left shunts. The diagnosis of brain abscess should prompt the clinician to consider right-to-left shunts as a possible predisposing condition for brain abscess.

  20. Balanced calibration of resonant shunt circuits for piezoelectric vibration control

    DEFF Research Database (Denmark)

    Høgsberg, Jan; Krenk, Steen

    2012-01-01

    Shunting of piezoelectric transducers and suitable electric circuits constitutes an effective passive approach to resonant vibration damping of structures. Most common design concepts for resonant resistor-inductor (RL) shunt circuits rely on either maximization of the attainable modal damping...

  1. Nonmedical application of computed tomography to power capacitor quality assesment

    International Nuclear Information System (INIS)

    Kruger, R.P.

    1981-01-01

    Present research and development efforts at Los Alamos Scientific Laboratory require the design and use of high-efficiency rapid-discharge energy storage capacitors for laser isotope separation and plasma physics programs. In these applications, capacitors are subjected to electrical, mechanical, thermal, and other environmental stresses. These stresses cause the dielectric constant to change due to gasification from arcing at nonsoldering connections, which produce a chemical reduction of the dielectric material. This effectively limits the lifetime of the capacitor. The programs mentioned above require capacitors with a multikilohertz frequency response at a current of tens of kiloamperes and a voltage of at least 100 kV. The lifetime of such capacitors should exceed 10 10 charge/discharge cycles. Such capacitors do not presently exist. The exploration of new capacitor designs will require the use of both electrical functional tests and tests that show the changes in internal physical structure as the capacitor is repeatedly stressed by the charge/discharge cycle. The integration of electrical and structural tests throughout the life cycle of a candidate capacitor makes it imperative that the structural integrity tests be nondestructive. Computed tomography (CT) makes this integration possible. The work reported here is the result of a pilot project designed to show the potential use of CT for this application. This work includes visualization of material defects using both a layered sequence of conventional tomographic slices and orthogonal multiangular pseudoradiographs generated from these slices

  2. Li-Ion, Ultra-capacitor Based Hybrid Energy Module

    National Research Council Canada - National Science Library

    Daboussi, Zaher; Paryani, Anil; Khalil, Gus; Catherino, Henry; Gargies, Sonya

    2007-01-01

    .... To determine the optimum utilization of ultra-capacitors in applications where high power density and high energy density are required, an optimized Li-Ion/Ultra-capacitor Hybrid Energy Module (HEM...

  3. A light-powered bio-capacitor with nanochannel modulation.

    Science.gov (United States)

    Rao, Siyuan; Lu, Shanfu; Guo, Zhibin; Li, Yuan; Chen, Deliang; Xiang, Yan

    2014-09-03

    An artificial bio-capacitor system is established, consisting of the proton-pump protein proteorhodopsin and a modified alumina nanochannel, inspired by the capacitor-like behavior of plasma membranes realized through the cooperation of ion-pump and ion-channel proteins. Capacitor-like features of this simplified system are realized and identified, and the photocurrent duration time can be modulated by nanochannel modification to obtain favorable square-wave currents. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Method of making dielectric capacitors with increased dielectric breakdown strength

    Science.gov (United States)

    Ma, Beihai; Balachandran, Uthamalingam; Liu, Shanshan

    2017-05-09

    The invention is directed to a process for making a dielectric ceramic film capacitor and the ceramic dielectric laminated capacitor formed therefrom, the dielectric ceramic film capacitors having increased dielectric breakdown strength. The invention increases breakdown strength by embedding a conductive oxide layer between electrode layers within the dielectric layer of the capacitors. The conductive oxide layer redistributes and dissipates charge, thus mitigating charge concentration and micro fractures formed within the dielectric by electric fields.

  5. Microprocessor Controlled Capacitor Bank Switching System for ...

    African Journals Online (AJOL)

    In this work, analysis and development of a microprocessor controlled capacitor bank switching system for deployment in a smart distribution network was carried out. This system was implemented by the use of discreet components such as resistors, capacitors, transistor, diode, automatic voltage regulator, with the ...

  6. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  7. Comparison of MOS capacitor and transistor postirradiation response

    International Nuclear Information System (INIS)

    McWhorter, P.J.; Fleetwood, D.M.; Pastorek, R.A.; Zimmerman, G.T.

    1989-01-01

    The postirradiation response of MOS capacitors and transistors fabricated on the same chip has been examined as a function of dose and anneal bias. A variety of analysis techniques are used to evaluate the postirradiation response of these structures, including low and high frequency capacitance-voltage techniques, subthreshold current-voltage techniques, and charge pumping. Though there are changes in the postirradiation energy spectrum of ΔD it , no clear evidence of defect transformation is observed on transistors or capacitors under any conditions examined. Postirradiation response at 80 degrees C is found to be similar in the two structures for low levels of damage (100 krad). For both structures, interface-trap densities continue to grow following irradiation under these conditions. In contrast, the postirradiation response of capacitors and transistors can differ qualitatively at higher levels of damage (1 Mrad), with interface-traps increasing postirradiation at 80 degrees C for transistors and annealing for capacitors. These results indicate that capacitor structures may not be suitable for hardness assurance studies that involve elevated temperature irradiations or postirradiation anneals

  8. Study of electric capacitors using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Alina Neamț

    2012-12-01

    Full Text Available A capacitor is made of two armatures and a dielectric between the two armatures. In this paper, we are going to study the plane capacitor , which is made of two equal metal armatures, plane and parallel, having the S surface, situated at a distance d much shorter than the armatures dimensions, between which there is a liniar, homogenous and isotropic dielectric having a constant electrical permittivity.The purpose of studying the plane capacitor, through MEF, presented in this paper,is to establish the stress to which the dielectrics may be subject to, in daily practice, and the influence that their superposition in an electric field has, on each of them. The study of the plane capacitor , finalised with observations on the raise of the dependence of the electric field intensity in air on the size of the air layer and having as parameter the type of dielectric material introduced between the armatures, is an example of confirmation or invalidation of the possibility and utility of using layers of dielectrics between the armatures of the capacitors.

  9. Reliability Evaluation of Base-Metal-Electrode (BME) Multilayer Ceramic Capacitors for Space Applications

    Science.gov (United States)

    Liu, David (Donghang)

    2011-01-01

    This paper reports reliability evaluation of BME ceramic capacitors for possible high reliability space-level applications. The study is focused on the construction and microstructure of BME capacitors and their impacts on the capacitor life reliability. First, the examinations of the construction and microstructure of commercial-off-the-shelf (COTS) BME capacitors show great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and approximately 0.5 micrometers, which is much less than that of most PME capacitors. The primary reasons that a BME capacitor can be fabricated with more internal electrode layers and less dielectric layer thickness is that it has a fine-grained microstructure and does not shrink much during ceramic sintering. This results in the BME capacitors a very high volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT) and regular life testing as per MIL-PRF-123. Most BME capacitors were found to fail· with an early dielectric wearout, followed by a rapid wearout failure mode during the HALT test. When most of the early wearout failures were removed, BME capacitors exhibited a minimum mean time-to-failure of more than 10(exp 5) years. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically between 10 and 20. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life

  10. A rare cause of pediatric urinary incontinence: Ventriculoperitoneal shunt with bladder perforation

    Directory of Open Access Journals (Sweden)

    Manuel C See IV

    2016-04-01

    Full Text Available We present a case of 2-year-old boy with long term dysuria and intermittent incontinence, and new onset of fever and headache. Significant past medical history includes congenital hydrocephalus with a ventriculoperitoneal shunt placement two years prior to consult. On physical examination, a tubular structure was noted underneath the prepuce suspected to be the distal tip of ventriculoperitoneal shunt, which was confirmed by kidney, ureter and bladder (KUB X-ray and CT scan. Patient was treated with a novel approach of extraperitoneal removal of ventriculoperitoneal shunt distal tip with cystorrhaphy via a low transverse pfannenstiel incision, separate left ventriculostomy tube insertion and complete removal of ventriculoperitoneal shunt from the right ventricle. This report accounts a rare pediatric case with ventriculoperitoneal shunt perforation into a normal bladder successfully treated with mini-open surgery.

  11. Rotary capacitor

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The rotating wheel of the rotary capacitor representing the most critical part of the new radio-frequency system of the synchro-cyclotron. The three rows of teeth on the circumference of the wheel pass between four rows of stator blades with a minimum clearance of 1 mm at a velocity of 1700 rev/min.

  12. Liquid Crystals of Lithium Dodecylbenzenesulfonate for Electric Double Layer Capacitors

    International Nuclear Information System (INIS)

    Kuzmin, Andrey Vasil’evich; Yurtov, Evgeny V.

    2016-01-01

    Ionic lyotropic liquid crystals based on lithium dodecylbenzenesulfonate were used as electrolytes for electric double layer capacitors with carbon fibrous electrodes. The capacitors were tasted by cyclic voltammetry, galvanostatic charge and discharge, and impedance spectroscopy. The highest specific capacitance was achieved for electrical double layer capacitor equipped with ionic lyotropic liquid crystal of lithium dodecylbenzenesulfonate 35 wt% in water. The specific capacitance of capacitor was calculated from galvanostatic discharge curves – 15 F/g of carbon fibrous material

  13. 50V All-PMOS Charge Pumps Using Low-Voltage Capacitors

    KAUST Repository

    Emira, Ahmed

    2012-10-06

    In this work, two high-voltage charge pumps are introduced. In order to minimize the area of the pumping capacitors, which dominates the overall area of the charge pump, high density capacitors have been utilized. Nonetheless, these high density capacitors suffer from low breakdown voltage which is not compatible with the targeted high voltage application. To circumvent the breakdown limitation, a special clocking scheme is used to limit the maximum voltage across any pumping capacitor. The two charge pump circuits were fabricated in a 0:6m CMOS technology with poly0-poly1 capacitors. The output voltage of the two charge pumps reached 42:8V and 51V while the voltage across any capacitor did not exceed the value of the input voltage. Compared to other designs reported in the literature, the proposed charge pump provides the highest output voltage which makes it more suitable for tuning MEMS devices.

  14. 50V All-PMOS Charge Pumps Using Low-Voltage Capacitors

    KAUST Repository

    Emira, Ahmed; AbdelGhany, M.; Elsayed, M.; Elshurafa, Amro M.; Sedky, S.; Salama, Khaled N.

    2012-01-01

    In this work, two high-voltage charge pumps are introduced. In order to minimize the area of the pumping capacitors, which dominates the overall area of the charge pump, high density capacitors have been utilized. Nonetheless, these high density capacitors suffer from low breakdown voltage which is not compatible with the targeted high voltage application. To circumvent the breakdown limitation, a special clocking scheme is used to limit the maximum voltage across any pumping capacitor. The two charge pump circuits were fabricated in a 0:6m CMOS technology with poly0-poly1 capacitors. The output voltage of the two charge pumps reached 42:8V and 51V while the voltage across any capacitor did not exceed the value of the input voltage. Compared to other designs reported in the literature, the proposed charge pump provides the highest output voltage which makes it more suitable for tuning MEMS devices.

  15. Prenatal surgery for myelomeningocele and the need for cerebrospinal fluid shunt placement

    Science.gov (United States)

    Tulipan, Noel; Wellons, John C.; Thom, Elizabeth A.; Gupta, Nalin; Sutton, Leslie N.; Burrows, Pamela K.; Farmer, Diana; Walsh, William; Johnson, Mark P.; Rand, Larry; Tolivaisa, Susan; D’Alton, Mary E.; Adzick, N. Scott

    2016-01-01

    Object The Management of Myelomeningocele Study (MOMS) was a multicenter randomized trial comparing the safety and efficacy of prenatal and postnatal closure of myelomeningocele. The trial was stopped early because of the demonstrated efficacy of prenatal surgery, and outcomes on 158 of 183 pregnancies were reported. Here, the authors update the 1-year outcomes for the complete trial, analyze the primary and related outcomes, and evaluate whether specific prerandomization risk factors are associated with prenatal surgery benefit. Methods The primary outcome was a composite of fetal loss or any of the following: infant death, CSF shunt placement, or meeting the prespecified criteria for shunt placement. Primary outcome, actual shunt placement, and shunt revision rates for prenatal versus postnatal repair were compared. The shunt criteria were reassessed to determine which were most concordant with practice, and a new composite outcome was created from the primary outcome by replacing the original criteria for CSF shunt placement with the revised criteria. The authors used logistic regression to estimate whether there were interactions between the type of surgery and known prenatal risk factors (lesion level, gestational age, degree of hindbrain herniation, and ventricle size) for shunt placement, and to determine which factors were associated with shunting among those infants who underwent prenatal surgery. Results Ninety-one women were randomized to prenatal surgery and 92 to postnatal repair. The primary outcome occurred in 73% of infants in the prenatal surgery group and in 98% in the postnatal group (p < 0.0001). Actual rates of shunt placement were only 44% and 84% in the 2 groups, respectively (p < 0.0001). The authors revised the most commonly met criterion to require overt clinical signs of increased intracranial pressure, defined as split sutures, bulging fontanelle, or sunsetting eyes, in addition to increasing head circumference or hydrocephalus. Using

  16. Clopidogrel in infants with systemic-to-pulmonary-artery shunts

    DEFF Research Database (Denmark)

    Wessel, David L; Berger, Felix; Li, Jennifer S

    2013-01-01

    BACKGROUND: Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity relate......-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.)....

  17. Phenotypic and chemotypic characterization of GABA-shunt mutants in Arabidopsis thaliana

    OpenAIRE

    Mekonnen, Dereje Worku

    2013-01-01

    Gamma-Aminobutyric acid (GABA) is a four carbon non protein amino acid, and the pathway that involves its production and degradation is called the GABA shunt. The GABA shunt is a short enzymatic pathway that involves three enzymes: glutamate decarboxylase (GAD), GABA transaminase (GABA-T) and succinic semi aldehyde dehydrogenase (SSADH). GABA shunt is conserved almost in all organisms studied so far. The pathway starts in the cytosol and finishes in mitochondria in higher organisms like plant...

  18. Negative capacitance in a ferroelectric capacitor.

    Science.gov (United States)

    Khan, Asif Islam; Chatterjee, Korok; Wang, Brian; Drapcho, Steven; You, Long; Serrao, Claudy; Bakaul, Saidur Rahman; Ramesh, Ramamoorthy; Salahuddin, Sayeef

    2015-02-01

    The Boltzmann distribution of electrons poses a fundamental barrier to lowering energy dissipation in conventional electronics, often termed as Boltzmann Tyranny. Negative capacitance in ferroelectric materials, which stems from the stored energy of a phase transition, could provide a solution, but a direct measurement of negative capacitance has so far been elusive. Here, we report the observation of negative capacitance in a thin, epitaxial ferroelectric film. When a voltage pulse is applied, the voltage across the ferroelectric capacitor is found to be decreasing with time--in exactly the opposite direction to which voltage for a regular capacitor should change. Analysis of this 'inductance'-like behaviour from a capacitor presents an unprecedented insight into the intrinsic energy profile of the ferroelectric material and could pave the way for completely new applications.

  19. Effect of capacitor loss on discharging characteristics of xenon flash lamp

    International Nuclear Information System (INIS)

    Zhang Chu; Lin Dejiang; Xu Chunmei; Shen Hongbin; Chen Xiaohan

    2012-01-01

    The effect of storage capacitor's loss on the discharging characteristics of the xenon flash lamp was studied, and the xenon flash lamp discharging circuit was analyzed and improved. The capacitor can be equivalent to a series of an ideal capacitor and loss resistance. The improved formula of the xenon lamp discharging characteristics was given when actual capacitance loss is not zero, and the xenon lamp discharging current and discharging power are calculated and analyzed in detail with the increase of the capacitor loss. The results show that the increase of loss will lead to the decrease of xenon lamp discharging current and peak power and the xenon lamp flash time, and influence laser pumping efficiency. The loss will also lead to the capacitor inverse charging in LC discharging circuit; this will influence normal working of the capacitor and decrease the lift of the xenon lamp. The actual energy storage capacitor charging and discharging experiments show that the increase of capacitor loss will lead to the decrease of xenon lamp light-emitting waveform peak, shortening of the flash time and increase of the electrode sputter, thus verity, the reasonableness of theoretical analysis. In addition, the experiments show that environmental factors have very significant impact on the increase of the storage capacitor loss. (authors)

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt ( ...

  1. Electrically and thermally activated ageing mechanisms in metallised polymer film capacitors

    International Nuclear Information System (INIS)

    Lee, Yuen Pen

    2001-01-01

    This dissertation describes a combined computational and experimental study to understand the fundamental electrostatic, thermal, electromagnetic, and discharge related processes during the ageing of metallised polymer film capacitors. In the event of internal breakdowns, these capacitors are capable of 'self-healing' through a controlled isolation of defects on the electrode surfaces by mosaic patterning the electrode. The objective of this project is to develop viable computer models to unravel electrothermally activated ageing processes in capacitors. To provide the necessary validation to any capacitor models developed, our work is supported by comprehensive experiments including industrial standard accelerated life tests and associated breakdown damage analyses of tested capacitors. These have enabled an empirical identification of main factors affecting the reliability and lifetime of capacitors. Relevant raw data and the qualitative picture enabled by these data are crucial to the development and refinement of viable computational models of capacitors. Given the complexity of ageing processes, it is both very difficult and unnecessary to develop a one-for-all model that describes indiscriminately all relevant processes. The approach adapted in this work has been to prioritise key ageing processes and modularise each process with its own computer model. The overall picture of capacitor ageing can then be unravelled by integrating all modules together. For instance, the fine geometrical features of the electrode mosaic pattern and the capacitor's laminated structure have been assessed through a concept of field intensification using a 2D electrostatic finite element computation. With fine geometrical features accounted for by the field intensification concept, fast electric events in capacitors can be simulated using a simple equivalent circuit model. Similar assessment of heat transfer has led to an equally efficient modelling of thermal events in capacitors

  2. Practical Considerations of the Start-up Procedure for an Active Capacitor

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Qian; Geng, Tao

    2017-01-01

    Capacitive DC links provide the only low-impedance current path connected with an input source during the start-up of many voltage source converters. A soft-start circuit is usually implemented to limit the inrush current. A two-terminal active capacitor is recently proposed which can directly...... replace conventional passive capacitors in DC links, with reduced cost or size for a given application. The active capacitor has the same level of convenience with two power terminals only as a passive capacitor. This paper proposes two start-up schemes for the active capacitor to overcome the drawbacks...... of existing methods previously widely used for passive capacitors. One scheme is based on a trade-off design between the start-up performance and the component sizing of the active capacitor. The other scheme is based on either an additional bypass switch together with the existing soft-start circuit...

  3. An Active Damping Technique for Small DC-Link Capacitor Based Drive System

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Lu, Kaiyuan

    2013-01-01

    A small dc-link capacitor based drive system shows instability when it is operated with large input line inductance at operating points with high power. This paper presents a simple, new active damping technique that can stabilize effectively the drive system at unstable operating points, offering...

  4. Stress effects of the inter-level dielectric layer on the ferroelectric performance of integrated SrBi2Ta2O9 capacitors

    International Nuclear Information System (INIS)

    Hong, Suk-Kyoung; Yang, B.; Oh, Sang Hyun; Kang, Young Min; Kang, Nam Soo; Hwang, Cheol Seong; Kwon, Oh Seong

    2001-01-01

    The thermal stress effects of the inter-level dielectric (ILD) layer on the ferroelectric performance of integrated Pt/SrBi 2 Ta 2 O 9 (SBT)/Pt capacitors were investigated. Two different thin film materials, pure SiO 2 grown at 650 degree C and B- and P-doped SiO 2 grown at 400 degree C by chemical vapor deposition techniques, were tested as an ILD layer. The ILD layer encapsulated the SBT capacitor array. During high temperature thermal cycling (up to 800 degree C) after ILD deposition, which is used for both densifying the ILD and curing of the various damage imposed on the SBT capacitors, a large thermal stress occurred in the bottom Pt layer due to the thermal expansion mismatch between the various layers. In particular, the pure SiO 2 ILD layer between the capacitors did not allow thermal expansion of the Pt layers, which led to a large accumulation of compressive stress in the layer. This resulted in hillock formation in the bottom Pt layer and eventual capacitor failure. However, the B- and P-doped SiO 2 ILD layer contracted during thermal cycling by removing residual impurities, which allowed greater expansion of the Pt layer. Therefore, compressive stress accumulation did not occur and excellent ferroelectric properties were thus obtained from the integrated capacitor array. [copyright] 2001 American Institute of Physics

  5. Prevention and treatment of complications after transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    XUE Hui

    2016-02-01

    Full Text Available The application of transjugular intrahepatic portosystemic shunt (TIPS in the treatment of cirrhotic portal hypertension has been widely accepted both at home and abroad. This article focuses on the fatal complications of TIPS (including intraperitoneal bleeding and acute pulmonary embolism, shunt failure, and recurrent portosystemic hepatic encephalopathy, and elaborates on the reasons for such conditions and related preventive measures, in order to improve the accuracy and safety of intraoperative puncture, reduce common complications such as shunt failure and hepatic encephalopathy, and improve the clinical effect of TIPS in the treatment of cirrhotic portal hypertension.

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... a stent is placed to keep the connection open and allow it to bring blood draining from ... veins within the liver. The shunt is kept open by the placement of a small, tubular metal ...

  7. Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.

    Science.gov (United States)

    Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim

    2018-01-01

    Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Clinical and ultrasonographic criteria for using ventriculoperitoneal shunts in newborns with myelomeningocele

    Directory of Open Access Journals (Sweden)

    Jose Roberto Tude Melo

    2015-09-01

    Full Text Available Objective Hydrocephalus is one of the main complications associated with myelomeningocele (MM. This study aimed to identify clinical and ultrasonographic criteria for using ventriculoperitoneal (VP shunts in this group of patients.Method A retrospective cohort study, based on established protocol for VP shunt implant in hydrocephalic children with MM. Parameters used to guide the indication of VP shunts included measurement of head circumference (HC, evaluation of fontanels, and measurement of lateral ventricular atrium (LVA width by transcranial ultrasonography.Results 43 children were included in the analysis, of which 74% had hydrocephalus and required a VP shunt. These children had LVA width ≥ 15 mm, showed increased HC, or had bulging fontanels.Conclusion VP shunt is required in children with increased HC (≥ 2 standard deviation regarding age group, bulging fontanels, or LVA width of ≥ 15 mm after the closure of MM.

  9. Communicating hydrocephalus due to cerebral venous sinus thrombosis treated with ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Rahul T Chakor

    2012-01-01

    Full Text Available Cerebral venous sinus thrombosis (CVT is a rare cerebrovascular disease with variable presentation. CVT rarely causes hydrocephalus. Communicating hydrocephalus due to CVT is extremely rare. We describe a patient of CVT presenting with chronic headache and communicating hydrocephalus. The patient was successfully treated with ventriculoperitoneal (VP shunt. A 40 year old man presented with moderate to severe headache since six months and progressive visual loss since two months. Head Computed tomogram showed mild hydrocephalus without obstruction. Lumbar puncture (LP demonstrated elevated pressure but was otherwise normal. Magnetic resonance venogram showed extensive CVT. Repeated CSF drainage and thecoperitoneal shunt did not relieve the severe headache hence a VP shunt was placed. Post shunt headache subsided with resolution of hydrocephalus. CVT can present as communicating hydrocephalus. Gradual reduction of intra-ventricular pressure by repeated LPs followed by VP shunt can safely treat hydrocephalus due to CVT.

  10. Renal Arteriovenous Shunts: Clinical Features, Imaging Appearance, and Transcatheter Embolization Based on Angioarchitecture.

    Science.gov (United States)

    Maruno, Miyuki; Kiyosue, Hiro; Tanoue, Shuichi; Hongo, Norio; Matsumoto, Shunro; Mori, Hiromu; Sagara, Yoshiko; Kashiwagi, Junji

    2016-01-01

    Renal arteriovenous (AV) shunt, a rare pathologic condition, is divided into two categories, traumatic and nontraumatic, and can cause massive hematuria, retroperitoneal hemorrhage, pain, and high-output heart failure. Although transcatheter embolization is a less-invasive and effective treatment option, it has a potential risk of complications, including renal infarction and pulmonary embolism, and a potential risk of recanalization. The successful embolization of renal AV shunt requires a complete occlusion of the shunted vessel while preventing the migration of embolic materials and preserving normal renal arterial branches, which depends on the selection of adequate techniques and embolic materials for individual cases, based on the etiology and imaging angioarchitecture of the renal AV shunts. A classification of AV malformations in the extremities and body trunk could precisely correspond with the angioarchitecture of the nontraumatic renal AV shunts. The selection of techniques and choice of adequate embolic materials such as coils, vascular plugs, and liquid materials are determined on the basis of cause (eg, traumatic vs nontraumatic), the classification, and some other aspects of the angioarchitecture of renal AV shunts, including the flow and size of the fistulas, multiplicity of the feeders, and endovascular accessibility to the target lesions. Computed tomographic angiography and selective digital subtraction angiography can provide precise information about the angioarchitecture of renal AV shunts before treatment. Color Doppler ultrasonography and time-resolved three-dimensional contrast-enhanced magnetic resonance angiography represent useful tools for screening and follow-up examinations of renal AV shunts after embolization. In this article, the classifications, imaging features, and an endovascular treatment strategy based on the angioarchitecture of renal AV shunts are described. (©)RSNA, 2016.

  11. Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt

    Science.gov (United States)

    Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong

    2017-07-01

    Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  13. Endoscopic Third Ventriculostomy Instead of Shunt Revision in Children Younger Than 3 Years of Age.

    Science.gov (United States)

    Zhao, Rui; Shi, Wei; Yang, Haowei; Li, Hao

    2016-04-01

    Endoscopic third ventriculostomy (ETV) is a valuable option in the treatment of shunt failure, but no clinical data exist for young children. The aim of this study was to elucidate the role of ETV in patients younger than 3 years of age with shunt malfunction. A cohort of 37 patients younger than 3 years of age with shunt malfunction underwent ETV instead of shunt revision. Patients' preoperative condition and medical history were studied to determine the impact of a number of variables on outcome. The Fisher exact test was used to assess differences among groups. Median age at ETV was 21.6 months (8-36 months). Diagnosis was obstructive hydrocephalus in 24 patients and communicating hydrocephalus in 13. Median age at initial shunt placement was 3.2 months (10 days to 30 months). The etiology of shunt malfunction was obstruction (n = 27) or infection (n = 10). Overall ETV failure rate was 40.5% (15/37). Patients whose age at initial shunt placement was <6 months and/or who had a preterm birth history had higher relative rates of ETV failure. Other variables, including type of hydrocephalus, interval between initial shunt placement and ETV, history of intraventricular bleeding and/or infection, and etiology of shunt malfunction, did not significantly affect the final outcome. Patients younger than 3 years with obstructive or communicating hydrocephalus may benefit from ETV in the event of shunt malfunction and have about a 60% probability of becoming shunt free. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Percutaneous Transjugular Direct Porto-caval Shunt in Patients with Budd-Chiari Syndrome

    International Nuclear Information System (INIS)

    Quateen, A.; Pech, M.; Berg, T.; Bergk, A.; Podrabsky, P.; Felix, R.; Ricke, J.

    2006-01-01

    The purpose of the study was to evaluate the feasibility and effectiveness of direct porto-caval shunts in patients with Budd-Chiari syndrome (BCS) in whom there is no access to the hepatic veins during transjugular intrahepatic portosystemic shunt (TIPSS). We included six consecutive patients with fulminant/acute Budd-Chiari syndrome (mean age: 35 years) in whom a conventional TIPSS was not possible due to inaccessible hepatic veins. We performed a direct porto-caval shunt via a transhepatic approach. Patients were followed up by means of clinical examination, laboratory investigations, and Doppler ultrasound. TIPSS implantation from the inferior vena cava (IVC) was successful in all six patients (100%). The median transhepatic shunt length was 9 cm (8-10 cm). No procedure-related complications were observed in our patients. Early shunt occlusion occurred in three out of six patients (50%). In all three of these patients, the stent used to stabilize the shunt ended 1-2 cm before reaching the IVC. All occlusions were successfully recanalized. One of these patients developed recurrent early shunt as well as mesenteric and splenic vein occlusions. She died 7 days after TIPSS placement due to an unmanageable coagulation disorder. The remaining five patients were followed up by planned clinical examination and laboratory investigations (mean follow-up time was 15 months; patient 1 was followed up for 13 months, patient 2 for 14 months, patient 3 for 15 months, and patients 4 and 5 for 16 months) and all displayed a complete and durable resolution of liver failure and ascites without reintervention. In patients with acute liver failure originating from BCS and inaccessible hepatic veins, a direct transhepatic porto-caval shunt can be performed safely and effectively under ultrasound guidance. Future studies in larger patient groups should investigate if the patency of transcaval TIPSS with long transhepatic shunt segments is similar compared to conventional TIPSS via

  15. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2011-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  16. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2012-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  17. Iodine encapsulation in CNTs and its application for electrochemical capacitor

    International Nuclear Information System (INIS)

    Taniguchi, Y.; Ishii, Y.; Al-zubaidi, A.; Kawasaki, S.; Rashid, M.; Syakirin, A.

    2016-01-01

    We report the experimental results for new type electrochemical capacitor using iodine redox reaction in single-walled carbon nanotubes (SWCNTs). It was found that the energy density of the present redox capacitor using SWCNTs is almost three times larger than that of the normal electric double layer capacitor.

  18. Iodine encapsulation in CNTs and its application for electrochemical capacitor

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Y.; Ishii, Y.; Al-zubaidi, A.; Kawasaki, S., E-mail: kawasaki.shinji@nitech.ac.jp [Nagoya Institute of Technology, Gokiso, Showa, Nagoya, Aichi (Japan); Rashid, M.; Syakirin, A. [Universiti Teknologi MARA (UiTM), 40450 Shah Alam, Selangor (Malaysia)

    2016-07-06

    We report the experimental results for new type electrochemical capacitor using iodine redox reaction in single-walled carbon nanotubes (SWCNTs). It was found that the energy density of the present redox capacitor using SWCNTs is almost three times larger than that of the normal electric double layer capacitor.

  19. Secondary pediatric encephalocele after ventriculosubgaleal shunting for posthemorrhagic hydrocephalus.

    Science.gov (United States)

    Seeburg, Daniel; Ahn, Edward; Huisman, Thierry

    2014-08-01

    Intraventricular hemorrhage and posthemorrhagic hydrocephalus continue to be common complications in very low-birth-weight premature infants, often requiring ventricular shunting for cerebrospinal fluid diversion. We report on two infants with posthemorrhagic hydrocephalus that developed a secondary encephalocele after ventriculosubgaleal shunting. Encephaloceles can act as a source of seizure activity and can result in various additional complications including meningitis, abscess formation, and infarction of herniated brain parenchyma. With continued improvements in neonatal intensive care, the survival of infants with significant medical comorbidities-including those that develop posthemorrhagic hydrocephalus requiring ventricular shunting-continues to increase. It is thus important for the radiologist and treating physician to be aware of this rare, potential complication. Georg Thieme Verlag KG Stuttgart · New York.

  20. Impaired arm development after Blalock-Taussig shunts in adults with repaired tetralogy of Fallot.

    Science.gov (United States)

    Le Gloan, Laurianne; Marcotte, François; Leduc, Hugues; Mercier, Lise-Andrée; Dore, Annie; Mongeon, François-Pierre; Ibrahim, Reda; Miro, Joaquim; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2013-09-30

    Many adults with repaired tetralogy of Fallot have had prior Blalock-Taussig shunts. These shunts may theoretically hinder growth and development of the ipsilateral arm. We prospectively enrolled consecutive patients with tetralogy of Fallot in a cross-sectional study to measure arm length and assess handgrip strength. Bilateral handgrip strength was quantified by a dynamometer in a standing position after instructing patients to clench each hand tightly in succession. The maximum force achieved, in kilograms, was measured. A total of 80 consecutive adults with tetralogy of Fallot, aged 36.0 ± 12.5 years, 49% female, were prospectively enrolled. Thirty-eight (47.5%) patients had prior Blalock-Taussig shunts at a median age of 1.0 year. Twenty-one (55.3%) were left-sided and 23 (60.5%) were classic shunts. All but six patients with right-sided shunts and one without a prior shunt were right-handed. The shunts were present for a median of 4.0 years prior to takedown during corrective surgery. The arm ipsilateral to the shunt was significantly shorter than the contralateral arm (71.5 ± 6.1 versus 73.6 ± 5.6 cm, Ptetralogy of Fallot, Blalock-Taussig shunts may impair normal development of the ipsilateral arm with repercussions in adulthood that include shorter limb length and reduced handgrip strength. These changes are most pronounced in patients with classic end-to-side anastomoses. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Creation of transcatheter aortopulmonary and cavopulmonary shunts using magnetic catheters: feasibility study in swine.

    Science.gov (United States)

    Levi, Daniel S; Danon, Saar; Gordon, Brent; Virdone, Nicky; Vinuela, Fernando; Shah, Sanjay; Carman, Greg; Moore, John W

    2009-05-01

    Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  3. Forty years of shunt surgery at Rigshospitalet, Denmark

    DEFF Research Database (Denmark)

    Mansson, Philip Kofoed; Johansson, Sofia; Ziebell, Morten

    2017-01-01

    Objective The objective of this study is to review our experience of shunt surgery by investigating 40years of development in terms of rates of revision and infection, shunt survival and risk factors. Design and participants Medical records and operative reports were reviewed retrospectively...... for all patients who underwent primary shunt surgery at our department in the years 2010 to 2012. All results were compared with a previous study from our department. A mixed population consisting of 434 patients was included. Adults (≥15years) accounted for 89.9% of all patients and the mean follow.......1-54.9). Within 4weeks postoperatively, 3.2% had an infection and overall infection rate was 5.5%. Short duration of surgery and the use of antibiotic prophylaxis were associated with a lower risk of infection. The most frequent causes of revision were valve defects (18.4%) and proximal defects or obstructions...

  4. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active ...

  5. Improving the mechanical stability of a standard capacitor

    CSIR Research Space (South Africa)

    Moodley, SS

    2003-04-01

    Full Text Available temperature coefficients of capacitance, they were susceptible to mechanical shock. During 1999, a project was initiated to improve the mechanical stability of the capacitors after two capacitors were damaged during transit, while being transported as separate...

  6. Cellulose triacetate, thin film dielectric capacitor

    Science.gov (United States)

    Yen, Shiao-Ping S. (Inventor); Jow, T. Richard (Inventor)

    1995-01-01

    Very thin films of cellulose triacetate are cast from a solution containing a small amount of high boiling temperature, non-solvent which evaporates last and lifts the film from the casting surface. Stretched, oriented, crystallized films have high electrical breakdown properties. Metallized films less than about 2 microns in thickness form self-healing electrodes for high energy density, pulsed power capacitors. Thicker films can be utilized as a dielectric for a capacitor.

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  8. Biophysical shunt theory for neuropsychopathology: Part I.

    Science.gov (United States)

    Naisberg, Y; Avnon, M; Weizman, A

    1995-11-01

    We present a new model of the origin of schizophrenia based on biophysical ionic shunts in neuronal (electrical) pathways. Microstructural and molecular evidence is presented for the way in which changes in the neuronal membrane ionic channels may facilitate membrane property rearrangement, leading to a change in the density and composition of the ion channel charge which in turn causes a change in ionic flow orientation and distribution. We suggest that, under abnormal conditions, ionic flow shunts are created which redirect the biophysical collateral neuronal (electrical) pathways, resulting in psychiatric signs and symptoms. This model is complementary to the biological basis of schizophrenia.

  9. Muzzle shunt augmentation of conventional railguns

    International Nuclear Information System (INIS)

    Parker, J.V.

    1991-01-01

    This paper reports on augmentation which is a technique for reducing the armature current and hence the armature power dissipation in a plasma armature railgun. In spite of the advantages, no large augmented railguns have been built, primarily due to the mechanical and electrical complexity introduced by the extra conductors required. it is possible to achieve some of the benefits of augmentation in a conventional railgun by diverting a fraction φ of the input current through a shunt path at the muzzle of the railgun. In particular, the relation between force and armature current is the same as that obtained in an n-turn, series-connected augmented railgun with n = 1/(1 - φ). The price of this simplification is a reduction in electrical efficiency and some additional complexity in the external electrical system

  10. Detection of intracardiac shunts with contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Manning, W.J.; Atkinson, D.J.; Parker, J.A.; Edelman, R.R.

    1990-01-01

    This paper reports on ultrafast MR imaging with bolus administration of Gd-DTPA used to detect intracardiac shunts. Ten patients who had recently undergone cardiac catheterization or first-pass radionuclide evaluation were selected for study. These included five patients without intracardiac shunts and five patients with shunts (three with atrial septal defect, two with ventricular septal defect). Resting four-chamber cardiac images were obtained during intravenous injection of Gd-DTPA (0.02 mmol/kg) with an ultrafast, T1-weighted sequence. Images were acquired over 380 msec, with repetitive images obtained with each QRS for 50 beats. In addition, standard MR cine examinations were performed

  11. Reliability Evaluation of Base-Metal-Electrode Multilayer Ceramic Capacitors for Potential Space Applications

    Science.gov (United States)

    Liu, David (Donhang); Sampson, Michael J.

    2011-01-01

    Base-metal-electrode (BME) ceramic capacitors are being investigated for possible use in high-reliability spacelevel applications. This paper focuses on how BME capacitors construction and microstructure affects their lifetime and reliability. Examination of the construction and microstructure of commercial off-the-shelf (COTS) BME capacitors reveals great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and 0.5 m, which is much less than that of most PME capacitors. BME capacitors can be fabricated with more internal electrode layers and thinner dielectric layers than PME capacitors because they have a fine-grained microstructure and do not shrink much during ceramic sintering. This makes it possible for BME capacitors to achieve a very high capacitance volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT). Most BME capacitors were found to fail with an early avalanche breakdown, followed by a regular dielectric wearout failure during the HALT test. When most of the early failures, characterized with avalanche breakdown, were removed, BME capacitors exhibited a minimum mean time-to-failure (MTTF) of more than 105 years at room temperature and rated voltage. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically around 12 for a number of BME capacitors with a rated voltage of 25V. This may suggest that the number of grains per dielectric layer is more critical than the

  12. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  13. Charge retention characteristics of (Bi,La)4Ti3O12 capacitors : comparison with Pb(Zr,Ti)O3 capacitors

    International Nuclear Information System (INIS)

    Yoon, J. G.; Kim, D. J.; So, Y. W.

    2005-01-01

    We investigated the retention characteristics of (Bi,La) 4 Ti 3 O 12 (BLT) capacitors with Pt electrodes and compared them with Pb(Zr,Ti)O 3 (PZT) capacitors in the same- and opposite-state retentions. Polarization relaxations in short-time regime (t < 100 s) were well described by a power-law decay function, but the polarization relaxation of BLT was more significant than that of PZT. We discuss the difference in the relaxation process of polarization in conjunction with film microstructures and magnitudes of polarization for BLT and PZT. In long-time opposite-state retention, BLT capacitors showed much better characteristics than PZT. For both BLT and PZT, the opposite-state retention loss was governed by the development of an internal field during retention. For BLT capacitors, internal field development was much weaker than for PZT after retention, resulting in a good opposite-state retention. Structural and electrical properties are discussed in conjunction with the retention characteristics of the materials.

  14. Radionuclide cisternography in diagnostics of obstruction hydrocephalus in introduced ventricculoperitoneal shunt

    International Nuclear Information System (INIS)

    Cernochova, I.; Lipina, R.

    2004-01-01

    To confirm or exclude a diagnosis of internal obstruction hydrocephalus in an 8-year old girl with an introduced ventriculoperitoneal (V-P) shunt Establishing the V-P shunt is indisputably the route of choice in non-communicating hydrocephalus. The existence of a V-P shunt, however, is connected with numerous risks, especially of injuries, infection as well as increased intraabdominal pressure - e.g. in pregnancy. The development of endoscopy in neurosurgery allows the creation of communication via the bottom of the third ventricle with basal cisterns, and the subsequent cancellation of a V-P shunt. We describe the case of an 8-year old girl with congenital internal hydrocephalus with an assumed obliteration of the Sylvian aqueduct with an established V-P shunt. An MR scan described the membrane in the area of the Sylvian aqueduct, but the disproportion between the dilatation of the lateral ventricles, third ventricle and fourth ventricle led the physician to doubt as to the accuracy of the diagnosis of internal obstruction hydrocephalus. Therefore we performed a radionuclide cisternography (in a modified manner), which proved an existing communication between the third and fourth cerebral ventricle and which contradicted the clinical diagnosis of obstruction hydrocephalus. (author)

  15. Degradation failure model of self-healing metallized film pulse capacitor

    International Nuclear Information System (INIS)

    Sun Quan; Zhong Zheng; Zhou Jinglun; Zhao Jianyin; Wei Xiaofeng; Guo Liangfu; Zhou Pizhang; Li Yizheng; Chen Dehuai

    2004-01-01

    The high energy density self-healing metallized film pulse capacitor has been applied to all kinds of laser facilities for their power conditioning systems, whose reliability and expense are straightforwardly affected by the reliability level of the capacitors. Based on the related research in literature, this paper analyses the degradation mechanism of the capacitor, and presents a new degradation failure model--the Gauss-Poisson model. The Gauss-Poisson model divides degradation of capacitor into naturalness degradation and outburst one. Compared with traditional Weibull failure model, the new model is more precise in evaluating the lifetime of the capacitor, and the life tests for this model are simple in design, and lower in the cost of time or expense. The Gauss-Poisson model will be a fine and widely used degradation disable model. (author)

  16. Shunt-dependent hydrocephalus: management style among members of the American Society of Pediatric Neurosurgeons.

    Science.gov (United States)

    Kraemer, Mark R; Sandoval-Garcia, Carolina; Bragg, Taryn; Iskandar, Bermans J

    2017-09-01

    OBJECTIVE The authors conducted a survey to evaluate differences in the understanding and management of shunt-dependent hydrocephalus among members of the American Society of Pediatric Neurosurgeons (ASPN). METHODS Surveys were sent to all 204 active ASPN members in September 2014. One hundred thirty responses were received, representing a 64% response rate. Respondents were asked 13 multiple-choice and free-response questions regarding 4 fundamental problems encountered in shunted-hydrocephalus management: shunt malfunction, chronic cerebrospinal fluid (CSF) overdrainage, chronic headaches, and slit ventricle syndrome (SVS). RESULTS Respondents agreed that shunt malfunction occurs most often as the result of ventricular catheter obstruction. Despite contrary evidence in the literature, most respondents (66%) also believed that choroid plexus is the tissue most often found in obstructed proximal catheters. However, free-text responses revealed that the respondents' understanding of the underlying pathophysiology of shunt obstruction was highly variable and included growth, migration, or adherence of choroid plexus, CSF debris, catheter position, inflammatory processes, and CSF overdrainage. Most respondents considered chronic CSF overdrainage to be a rare complication of shunting in their practice and reported wide variation in treatment protocols. Moreover, despite a lack of evidence in the literature, most respondents attributed chronic headaches in shunt patients to medical reasons (for example, migraines, tension). Accordingly, most respondents managed headaches with reassurance and/or referral to pain clinics. Lastly, there were variable opinions on the etiology of slit ventricle syndrome (SVS), which included early shunting, chronic overdrainage, and/or loss of brain compliance. Beyond shunt revision, respondents reported divergent SVS treatment preferences. CONCLUSIONS The survey shows that there is wide variability in the understanding and management of

  17. Two-port laparoscopic management of a giant pseudocyst complicating ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Sandesh V Parelkar

    2014-01-01

    Full Text Available Insertion of a ventriculo-peritoneal (VP shunt is the most common operative procedure for the treatment of hydrocephalus in children. Of the several causes of shunt malfunction, cerebrospinal fluid (CSF pseudocyst is relatively uncommon. There are several modalities to treat a CSF pseudocyst. Laparotomy is required, at times, more than once. We managed a patient of CSF pseudocyst with two-port laparoscopy, by deroofing the psuedocyst and repositioning of the shunt. This minimally invasive technique avoids morbidity associated with laparotomy and aids in early recovery.

  18. An Active Capacitor with Self-Power and Internal Feedback Control Signals

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai

    2017-01-01

    This paper proposes a concept of two-terminal active capacitor implemented by power semiconductor switches and passive elements. The active capacitor has the same level of convenience as a passive one with two power terminals only. A control strategy that does not require any external feedback...... signal is proposed and a self-power scheme for gate drivers and the controller is applied to achieve the two-terminal active capacitor. The concept, control method, self-power scheme, efficiency, and impedance characteristics of the active capacitor are presented. A case study of the proposed active...... capacitor for a capacitive DC-link application is discussed. The results reveal a significantly lower overall energy storage of passive elements and a reduced cost to fulfill a specific reliability target, compared to a passive capacitor solution. Proof-of-concept experimental results are given to verify...

  19. An accurate on-site calibration system for electronic voltage transformers using a standard capacitor

    Science.gov (United States)

    Hu, Chen; Chen, Mian-zhou; Li, Hong-bin; Zhang, Zhu; Jiao, Yang; Shao, Haiming

    2018-05-01

    Ordinarily electronic voltage transformers (EVTs) are calibrated off-line and the calibration procedure requires complex switching operations, which will influence the reliability of the power grid and induce large economic losses. To overcome this problem, this paper investigates a 110 kV on-site calibration system for EVTs, including a standard channel, a calibrated channel and a PC equipped with the LabView environment. The standard channel employs a standard capacitor and an analogue integrating circuit to reconstruct the primary voltage signal. Moreover, an adaptive full-phase discrete Fourier transform (DFT) algorithm is proposed to extract electrical parameters. The algorithm involves the process of extracting the frequency of the grid, adjusting the operation points, and calculating the results using DFT. In addition, an insulated automatic lifting device is designed to realize the live connection of the standard capacitor, which is driven by a wireless remote controller. A performance test of the capacitor verifies the accurateness of the standard capacitor. A system calibration test shows that the system ratio error is less than 0.04% and the phase error is below 2‧, which meets the requirement of the 0.2 accuracy class. Finally, the developed calibration system was used in a substation, and the field test data validates the availability of the system.

  20. Association between right-to-left shunts and brain lesions in sport divers.

    Science.gov (United States)

    Gerriets, Tibo; Tetzlaff, Kay; Hutzelmann, Alfred; Liceni, Thomas; Kopiske, Gerrit; Struck, Niklas; Reuter, Michael; Kaps, Manfred

    2003-10-01

    Recent studies suggest that healthy sport divers may develop clinically silent brain damage, based on the association between a finding of multiple brain lesions on MRI and the presence of right-to-left shunt, a pathway for venous gas bubbles to enter the arterial system. We performed echocontrast transcranial Doppler sonography in 42 sport divers to determine the presence of a right-to-left shunt. Cranial MRI was carried out using a 1.5 T magnet. A lesion was counted if it was hyperintense on both T2-weighted and T2-weighted fluid attenuated inversion recovery sequences. To test the hypothesis that the occurrence of postdive arterial gas emboli is related to brain lesions on MRI, we measured postdive intravascular bubbles in a subset of 15 divers 30 min after open water scuba dives. Echocontrast transcranial Doppler sonography revealed a right-to-left shunt in 16 of the divers (38%). Only one hyperintensive lesion of the central white matter was found and that was in a diver with no evidence of a right-to-left shunt. Postdive arterial gas emboli were detected in 3 out of 15 divers; they had a right-to-left shunt, but no pathologic findings on cranial magnetic resonance imaging. Our data support the theory that right-to-left shunts can serve as a pathway for venous gas bubbles into the arterial circulation. However, we could not confirm an association between brain lesions and the presence of a right-to-left shunt in sport divers.

  1. Tunable band gaps in acoustic metamaterials with periodic arrays of resonant shunted piezos

    International Nuclear Information System (INIS)

    Chen Sheng-Bing; Wen Ji-Hong; Wang Gang; Wen Xi-Sen

    2013-01-01

    Periodic arrays of resonant shunted piezoelectric patches are employed to control the wave propagation in a two-dimensional (2D) acoustic metamaterial. The performance is characterized by the finite element method. More importantly, we propose an approach to solving the conventional issue of the nonlinear eigenvalue problem, and give a convenient solution to the dispersion properties of 2D metamaterials with periodic arrays of resonant shunts in this article. Based on this modeling method, the dispersion relations of a 2D metamaterial with periodic arrays of resonant shunted piezos are calculated. The results show that the internal resonances of the shunting system split the dispersion curves, thereby forming a locally resonant band gap. However, unlike the conventional locally resonant gap, the vibrations in this locally resonant gap are unable to be completely localized in oscillators consisting of shunting inductors and piezo-patches

  2. A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.

    Science.gov (United States)

    Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A

    2014-12-01

    Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

  3. Dynamics of a Liquid Dielectric Attracted by a Cylindrical Capacitor

    Science.gov (United States)

    Nardi, Rafael; Lemos, Nivaldo A.

    2007-01-01

    The dynamics of a liquid dielectric attracted by a vertical cylindrical capacitor are studied. Contrary to what might be expected from the standard calculation of the force exerted by the capacitor, the motion of the dielectric is different depending on whether the charge or the voltage of the capacitor is held constant. The problem turns out to…

  4. Ionic behavior of organic-inorganic metal halide perovskite based metal-oxide-semiconductor capacitors.

    Science.gov (United States)

    Wang, Yucheng; Zhang, Yuming; Pang, Tiqiang; Xu, Jie; Hu, Ziyang; Zhu, Yuejin; Tang, Xiaoyan; Luan, Suzhen; Jia, Renxu

    2017-05-24

    Organic-inorganic metal halide perovskites are promising semiconductors for optoelectronic applications. Despite the achievements in device performance, the electrical properties of perovskites have stagnated. Ion migration is speculated to be the main contributing factor for the many unusual electrical phenomena in perovskite-based devices. Here, to understand the intrinsic electrical behavior of perovskites, we constructed metal-oxide-semiconductor (MOS) capacitors based on perovskite films and performed capacitance-voltage (C-V) and current-voltage (I-V) measurements of the capacitors. The results provide direct evidence for the mixed ionic-electronic transport behavior within perovskite films. In the dark, there is electrical hysteresis in both the C-V and I-V curves because the mobile negative ions take part in charge transport despite frequency modulation. However, under illumination, the large amount of photoexcited free carriers screens the influence of the mobile ions with a low concentration, which is responsible for the normal C-V properties. Validation of ion migration for the gate-control ability of MOS capacitors is also helpful for the investigation of perovskite MOS transistors and other gate-control photovoltaic devices.

  5. Nonconventional mesocaval prosthetic shunt interposition in ...

    African Journals Online (AJOL)

    years demonstrates shunt patency and normal development ... However, the child's condition and growth ... The child has satisfactory weight and growth gain. (40kg .... infants and toddlers: replacement with decellularized branched pulmonary.

  6. On the leakage problem of MIM capacitors due to improper etching of titanium nitride

    NARCIS (Netherlands)

    Groenland, A.W.; Wolters, Robertus A.M.; Kovalgin, Alexeij Y.; Schmitz, Jurriaan

    2010-01-01

    In this work, Metal-insulator-metal (MIM) capacitor structures are fabricated in a technology using TiN as electrode material. The electrical characterization revealed devices with small and large leakage currents. Scanning Electron Microscopy (SEM) inspection showed a correlation between high

  7. Imaging of the ventriculoperitoneal shunt-related complications in infants and children with hydrocephalus

    International Nuclear Information System (INIS)

    Jeon, Se Ok; Kim, Ji Hye; Oh, Eun Young; Hwang, Hee Young; Lee, Seon Kyu; Lee, Eun Joo; Kwak, Min Sook; Kim, Hyung Sik

    1999-01-01

    To evaluate the frequency and imaging findings of various ventriculo-peritoneal shunt-related complications in pediatric patients with hydrocephalus. We retrospectively reviewed 246 plain radiographs, three shuntograms, 53 ultrasounds, 133 CT scans, and 24 MR images obtained before and after the ventriculo-peritoneal shunt procedure in 33 pediatric patients with hydrocephalus. Using preoperative images, the etiology of the hydrocephalus was assessed. Changes in the size and shape of the ventricles, the location and continuity of shunt apparatus, and the presence of any abnormal enhancement, hemorrhage, edema or tissue loss, or other findings of complications, were analyzed on postoperative images ; the frequency and imaging findings of shunt-related complications such as shunt malfunction, infection, homorrhage or isolated ventricle, and complications caused by overdrainage, were thus evaluated. The frequency of such complications was analyzed according to the etiology of the hydrocephalus, and in addition, medical records were reviewed and correlated with imaging findings. In 18 of the 33 patients(54%), a total of 31 complications was detected. These were present in four of five cases (80%) of hydrocephalus caused by meningitis and ventriculitis, seven of twelve (58%) intraventricular hemorrhage, two of four (50%) unknown cases, three of nine (33%) congenital malformations, one of two (50%) tumors, and one (100%) congenital infection. Shunt malfunction was most common (n=15), and was accompanied by findings of enlarged ventricles, periventricular and peritubal edema, and abnormal location of the shunt tube. Symptoms and signs of increased intracranial pressure were also noted. Subdural hemorrhage and infection were present in four cases each ; findings of infection were enhancement of the ventricular wall, meninges, and parenchyma, as well as sonographically noted intraventricular septation and increased ventricular wall echo. Isolated lateral ventricle (n=4) or 4

  8. Transmicrocatheter local injection of ethanol to treat hepatocellular carcinoma with high flow arteriovenous shunts

    International Nuclear Information System (INIS)

    Guan Shouhai; Shan Hong; Jiang Zaibo; Huang Mingsheng; Zhu Kangshun; Li Zhengran; Meng Xiaochun

    2002-01-01

    Objective: To evaluate the feasibility and clinical effect of embolization therapy in treating the high flow hepatic arteriovenous shunts in hepatocellular carcinoma (HCC) by locally injected ethanol through microcatheter. Methods: Forty-one branches of arteriovenous shunts were treated by local ethanol infusion through microcatheter in 29 patients suffered with HCC. Angiography was performed to observe the embolization effect and influence to non-targeted vessels. Result: Forty-one branches of arteriovenous shunts in 29 patients were injected with ethanol locally. Each single shunt was infused 1-6 times. The dose of ethanol was 2-3 ml per time, and the total dose of ethanol was 2-12 ml. All shunting tracts were embolized, and all non-target vessels were protected fluently. Iodine-oil deposition was well in continued TACE. Their syndromes were improved or disappeared. Conclusion: Transmicrocatheter injection of ethanol could safely and effectively treat the hepatic arteriovenous shunts and make advantages to TACE in HCC

  9. Cryptococcal cerebrospinal fluid shunt infection treated with fluconazole

    Directory of Open Access Journals (Sweden)

    Daniel Eymard

    1993-01-01

    Full Text Available A 37-year-old woman with a cadaveric renal allotransplantation required intra-cranial shunting devices after a presumptive episode of tuberculous meningitis. Six months later, she developed a culture-proven cryptococcal meningitis. Without having her ventriculo-auricular shunt removed, she was successfully treated with a short course of amphotericin B (335 mg and flucytosine (nine days followed by prolonged therapy with oral fluconazole (400 mg daily for 72 days. Three years post treatment she had no evidence of relapse, and normal renal graft function.

  10. [Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].

    Science.gov (United States)

    Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki

    2002-04-01

    We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.

  11. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    antibiotics and double gloving, by surgeons experienced in shunt surgery. Surgical incision, dissection and tunnelling were done. Then the surgeon, the scrub-nurse and, in three cases, the assistant made an imprint of their outer gloves on agar plates. Hereafter, they changed the outer pair of gloves before...... handling the shunt and completing the operation. The plates were cultured for 6 days in both aerobic and anaerobic environment. In all cases the surgeons gloves were contaminated, and in six cases also the nurses' gloves were contaminated, as well as all three assistants. Propionebacterium acnes were...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  12. Trench capacitor and method for producing the same

    NARCIS (Netherlands)

    2009-01-01

    A method of fabricating a trench capacitor, and a trench capacitor fabricated thereby, are disclosed. The method involves the use of a vacuum impregnation process for a sol-gel film, to facilitate effective deposition of high- permittivity materials within a trench in a semiconductor substrate, to

  13. Charging damage in floating metal-insulator-metal capacitors

    NARCIS (Netherlands)

    Ackaert, Jan; Wang, Zhichun; De Backer, E.; Coppens, P.

    2002-01-01

    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMC) is reported. The damage is caused by the build up of a voltage potential difference between the two plates of the capacitor. A simple logarithmic relation is discovered between the damage by this voltage

  14. Our initial experience with ventriculo-epiplooic shunt in treatment of hydrocephalus in two centers.

    Science.gov (United States)

    Grigorean, Valentin Titus; Sandu, Aurelia Mihaela; Popescu, Mihai; Florian, Ioan Stefan; Lupascu, Cristian Dumitru; Ursulescu, Corina Lupascu

    Hydrocephalus represents impairment in cerebrospinal fluid (CSF) dynamics. If the treatment of hydrocephalus is considered difficult, the repeated revisions of ventriculo-peritoneal (VP) shunts are even more challenging. The aim of this article is to evaluate the efficiency of ventriculo-epiplooic (VEp) shunt as a feasible alternative in hydrocephalic patients. A technical modification regarding the insertion of peritoneal catheter was imagined: midline laparotomy 8-10cm long was performed in order to open the peritoneal cavity; the great omentum was dissected between its two layers; we placed the distal end of the catheter between the two epiplooic layers; a fenestration of 4cm in diameter into the visceral layer was also performed. A retrospective study of medical records of 15 consecutive patients with hydrocephalus treated with VEp shunt is also presented. Between 2008 and 2014 we performed VEp shunt in 15 patients: 5 with congenital hydrocephalus, 8 with secondary hydrocephalus and 2 with normal pressure hydrocephalus. There were 7 men and 8 women. VEp shunt was performed in 13 patients with multiple distal shunt failures and in 2 patients, with history of abdominal surgery, as de novo extracranial drainage procedure. The outcome was favorable in all cases, with no significant postoperative complications. VEp shunt is a new, safe and efficient surgical technique for the treatment of hydrocephalus. VEp shunt is indicated in patients with history of recurrent distal shunt failures, and in patients with history of open abdominal surgery and high risk for developing abdominal complications. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  15. Enhanced dielectric constant and fatigue-resistance of PbZr0.4Ti0.6O3 capacitor with magnetic intermetallic FePt top electrode

    Science.gov (United States)

    Liu, B. T.; Zhao, J. W.; Li, X. H.; Zhou, Y.; Bian, F.; Wang, X. Y.; Zhao, Q. X.; Wang, Y. L.; Guo, Q. L.; Wang, L. X.; Zhang, X. Y.

    2010-06-01

    Both FePt/PbZr0.4Ti0.6O3(PZT)/Pt and Pt/PZT/Pt ferroelectric capacitors have been fabricated on Si substrates. It is found that up to 109 switching cycles, the FePt/PZT/Pt capacitor, measured at 50 kHz, with polarization decreased by 57%, is superior to the Pt/PZT/Pt capacitor by 82%, indicating that an intermetallic FePt top electrode can also improve the fatigue-resistance of a PZT capacitor. Maximum dielectric constants are 980 and 770 for PZT capacitors with FePt and Pt, respectively. This is attributed to the interface effect between PZT film and the top electrode since the interfacial capacitance of FePt/PZT is 3.5 times as large as that of Pt/PZT interface.

  16. Clocking Scheme for Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1998-01-01

    A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed.......A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed....

  17. Quantitative determination of peripheral arterio-venous shunts by means of radioactively labelled microspheres

    International Nuclear Information System (INIS)

    Friese, K.H.

    1981-01-01

    In the present work a nuclear method of quantitative measurement of peripheral arterio-venous shunts with a whole-body scanner is standardized. This method, developed at the beginning of the 70s at Tuebingen, stands out in contrast with earlier measuring methods by the application of the theory of quantitative scintiscanning. This means that the scintigram obtained after injection of sup(99m)technetium-labelled human albumin microspheres into an artery before the shunt is corrected for the quantitative shunt calculation by several factors using a computer, to avoid systematic mistakes. For the standardization of the method, 182 scintigrams were taken during model experiments and experiments on animals and human beings. This method, having a deviation of 10% at most, is excellently suited for the quantitative determination of peripheral arterio-venous shunts. Already for a pulmonary activity of 3% a peripheral shunt is proved with 97.5% probability. (orig./MG) [de

  18. Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

    Science.gov (United States)

    Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C

    2017-12-01

    The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

  19. Cellophane banding for the gradual attenuation of single extrahepatic portosystemic shunts in eleven dogs.

    Science.gov (United States)

    Youmans, K R; Hunt, G B

    1998-08-01

    To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts. A prospective trial of 11 dogs with single congenital extrahepatic shunts. Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively. The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion. Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.

  20. Cracking Problems and Mechanical Characteristics of PME and BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2018-01-01

    Most failures in MLCCs are caused by cracking that create shorts between opposite electrodes of the parts. A use of manual soldering makes this problem especially serious for space industry. Experience shows that different lots of ceramic capacitors might have different susceptibility to cracking under manual soldering conditions. This simulates a search of techniques that would allow revealing capacitors that are most robust to soldering-induced stresses. Currently, base metal electrode (BME) capacitors are introduced to high-reliability applications as a replacement of precious metal electrode (PME) parts. Understanding the difference in the susceptibility to cracking between PME and BME capacitors would facilitate this process. This presentation gives a review of mechanical characteristics measured in-situ on MLCCs that includes flexural strength, Vickers hardness, indentation fracture toughness, and the board flex testing and compare characteristics of BME and PME capacitors. A history case related to cracking in PME capacitors that caused flight system malfunctions and mechanisms of failure are considered. Possible qualification tests that would allow evaluation of the resistance of MLCCs to manual soldering are suggested and perspectives related to introduction of BME capacitors discussed.

  1. Stretchable Dual-Capacitor Multi-Sensor for Touch-Curvature-Pressure-Strain Sensing.

    Science.gov (United States)

    Jin, Hanbyul; Jung, Sungchul; Kim, Junhyung; Heo, Sanghyun; Lim, Jaeik; Park, Wonsang; Chu, Hye Yong; Bien, Franklin; Park, Kibog

    2017-09-07

    We introduce a new type of multi-functional capacitive sensor that can sense several different external stimuli. It is fabricated only with polydimethylsiloxane (PDMS) films and silver nanowire electrodes by using selective oxygen plasma treatment method without photolithography and etching processes. Differently from the conventional single-capacitor multi-functional sensors, our new multi-functional sensor is composed of two vertically-stacked capacitors (dual-capacitor). The unique dual-capacitor structure can detect the type and strength of external stimuli including curvature, pressure, strain, and touch with clear distinction, and it can also detect the surface-normal directionality of curvature, pressure, and touch. Meanwhile, the conventional single-capacitor sensor has ambiguity in distinguishing curvature and pressure and it can detect only the strength of external stimulus. The type, directionality, and strength of external stimulus can be determined based on the relative capacitance changes of the two stacked capacitors. Additionally, the logical flow reflected on a tree structure with its branches reaching the direction and strength of the corresponding external stimulus unambiguously is devised. This logical flow can be readily implemented in the sensor driving circuit if the dual-capacitor sensor is commercialized actually in the future.

  2. Management of Ventriculoperitoneal Shunt Infections in Adults: Analysis of Risk Factors Associated With Treatment Failure.

    Science.gov (United States)

    Pelegrín, Iván; Lora-Tamayo, Jaime; Gómez-Junyent, Joan; Sabé, Nuria; García-Somoza, Dolors; Gabarrós, Andreu; Ariza, Javier; Viladrich, Pedro Fernández; Cabellos, Carmen

    2017-04-15

    Little is known regarding the optimal treatment of ventriculoperitoneal (VP) shunt infections in adults. Our aim was to assess the efficacy of treatment strategies and to identify factors that predict failure. Retrospective, observational study of patients aged ≥12 years with VP shunt infections (1980 -2014). Therapeutic approaches were classified under 4 headings: only antibiotics (OA), one-stage shunt replacement (OSSR), two-stage shunt replacement (TSSR), and shunt removal without replacement (SR). The primary endpoint was failure of the treatment strategy, defined as the absence of definite cerebrospinal fluid (CSF) sterilization or related mortality. The parameters that predicted failure were analyzed using logistic regression. Of 108 episodes (51% male, median age 50 years), 86 were analyzed. Intravenous antibiotics were administered for a median of 19 days. Eighty episodes were treated using strategies that combined antibiotic and surgical treatment (37 TSSR, 24 SR, 19 OSSR) and 6 with OA. Failure occurred in 30% of episodes, mostly due to lack of CSF sterilization in OSSR and OA groups. Twelve percent died of related causes and 10% presented superinfection of the CSF temporary drainage/externalized peritoneal catheter. TSSR was the most effective strategy when VP shunt replacement was attempted. The only independent risk factor that predicted failure was retention of the VP shunt, regardless of the strategy. This is the largest series of VP shunt infections in adults reported to date. VP shunt removal, particularly TSSR when the patient is shunt dependent, remains the optimal choice of treatment and does not increase morbidity. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  3. Frontal and occipital horn ratio is associated with multifocal intraparenchymal hemorrhages in neonatal shunted hydrocephalus.

    Science.gov (United States)

    Oushy, Soliman; Parker, Jonathon J; Campbell, Kristen; Palmer, Claire; Wilkinson, Corbett; Stence, Nicholas V; Handler, Michael H; Mirsky, David M

    2017-11-01

    OBJECTIVE Placement of a cerebrospinal fluid diversion device (i.e., shunt) is a routine pediatric neurosurgical procedure, often performed in the first weeks of life for treatment of congenital hydrocephalus. In the postoperative period, shunt placement may be complicated by subdural, catheter tract, parenchymal, and intraventricular hemorrhages. The authors observed a subset of infants and neonates who developed multifocal intraparenchymal hemorrhages (MIPH) following shunt placement and sought to determine any predisposing perioperative variables. METHODS A retrospective review of the electronic medical record at a tertiary-care children's hospital was performed for the period 1998-2015. Inclusion criteria consisted of shunt placement, age hydrocephalus. Markers of severity of ventriculomegaly (FOR) and ventricular response to CSF diversion (∆FOR) were significantly associated with occurrence of MIPH. Choice of shunt and etiology of hydrocephalus were also significantly associated with MIPH. After adjusting for corrected age, etiology of hydrocephalus, and shunt setting, the authors found that ∆FOR after shunting was still associated with MIPH. A prospective study of MIPH prevention strategies and assessment of possible implications for patient outcomes is needed.

  4. Hypoxia and GABA shunt activation in the pathogenesis of Alzheimer's disease.

    Science.gov (United States)

    Salminen, Antero; Jouhten, Paula; Sarajärvi, Timo; Haapasalo, Annakaisa; Hiltunen, Mikko

    2016-01-01

    We have previously observed that the conversion of mild cognitive impairment to definitive Alzheimer's disease (AD) is associated with a significant increase in the serum level of 2,4-dihydroxybutyrate (2,4-DHBA). The metabolic generation of 2,4-DHBA is linked to the activation of the γ-aminobutyric acid (GABA) shunt, an alternative energy production pathway activated during cellular stress, when the function of Krebs cycle is compromised. The GABA shunt can be triggered by local hypoperfusion and subsequent hypoxia in AD brains caused by cerebral amyloid angiopathy. Succinic semialdehyde dehydrogenase (SSADH) is a key enzyme in the GABA shunt, converting succinic semialdehyde (SSA) into succinate, a Krebs cycle intermediate. A deficiency of SSADH activity stimulates the conversion of SSA into γ-hydroxybutyrate (GHB), an alternative route from the GABA shunt. GHB can exert not only acute neuroprotective activities but unfortunately also chronic detrimental effects which may lead to cognitive impairment. Subsequently, GHB can be metabolized to 2,4-DHBA and secreted from the brain. Thus, the activation of the GABA shunt and the generation of GHB and 2,4-DHBA can have an important role in the early phase of AD pathogenesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. ARTIFICIAL SHUNTING OF CEREBROSPINAL-FLUID

    NARCIS (Netherlands)

    HOEKSTRA, A

    A compact three-stage shunt valve system (Orbis SigmaTM Valve) which operates as a flow regulator within certain differential pressure values has been clinically evaluated in the treatment of hydrocephalus. Clinical trials were performed in 134 cases, covering 128 patients aged from 1 day to 79

  6. Transmission Line Resonator Segmented with Series Capacitors

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Boer, Vincent; Petersen, Esben Thade

    2016-01-01

    Transmission line resonators are often used as coils in high field MRI. Due to distributed nature of such resonators, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the resonator. The equations for optimal...... values of evenly distributed capacitors are presented. The performances of the segmented resonator and a regular transmission line resonator are compared....

  7. A Modified Shunt System for the Management of Pyogenic Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Abdul Naveed Khan

    2017-01-01

    Full Text Available BACKGROUND: To describe the structure and efficacy of a modified cerebrospinal fluid (CSF shunt system with Bhatti CSF access chamber and ventriculoperitoneal shunt, for the management of hydrocephalus associated with pyogenic ventriculitis. METHODS: This was an observational study performed at the National Medical Center and Ziauddin Medical University, Karachi, Pakistan. Chemically bonded Bhatti CSF access chamber and ventriculoperitoneal shunt was inserted into 443 patients with hydrocephalus and pyogenic ventriculitis to allow injection of antibiotics into the lateral ventricles. RESULTS: In all patients, symptoms and signs of hydrocephalus were relieved immediately after shunt insertion and infection brought under control within two weeks of intraventricular injection of antibiotics (vancomycin or linezolid, via the CSF access chamber. In two patients peritoneal catheter was blocked by a precipitate of vancomycin. Reduction in the dose of intraventricular vancomycin from 50mg to 20mg and increased dilution (additional 2ml of 0.9% N/S solution prevented recurrence of this complication. All patients recovered from ventriculitis within two weeks of initiating this treatment. Follow-up was from 3 months to 2 years to monitor continued relief of hydrocephalus and absence of recurrence of ventriculitis. CONCLUSION: Bhatti CSF access chamber and the ventriculoperitoneal shunt is the only system available at present that fulfills the management of hydrocephalus associated with pyogenic ventriculitis. It provides continuous internal drainage of CSF combined with access to the ventricles for injection of antibiotics.

  8. Shunts to divert aqueous humor to distant epithelialized cavities after keratoprosthesis surgery.

    Science.gov (United States)

    Dohlman, Claes H; Grosskreutz, Cynthia L; Chen, Teresa C; Pasquale, Louis R; Rubin, Peter A D; Kim, Eva C; Durand, Marlene

    2010-02-01

    Glaucoma is a frequent and often severe problem in patients needing keratoprosthesis (KPro) surgery. Standard glaucoma shunts in these cases often develop a very dense capsule that obstructs flow and causes intraocular pressure elevation. Therefore, we developed shunts that deliver aqueous to distant epithelialized cavities where an obstructing capsule is less likely to form. In this retroactive study of such shunts, the risk of postoperative infection (especially endophthalmitis) has been assessed. Ahmed shunts were connected with a tube to the lacrimal sac or ethmoid sinuses. In subsequent designs the polypropylene plate was eliminated, the valve was enclosed and a distal tube added (New World Medical Inc, Rancho Cucamonga, CA). The latter shunts were connected to the maxillary sinus or lower lid fornix. Between 2001 and 2005 the devices were implanted in 34 patients with very severe ocular disease. (31 had KPro implanted). Thus, the distal tube was led to the lacrimal sac (2 cases), to the ethmoid sinuses (6), to the maxillary sinus (16 cases), and to the lower lid fornix (10 cases). The patients were followed for cumulatively 145 shunt years, with a mean follow-up of 4 years and 3 months. They were instructed to administer low-dose topical antibiotics indefinitely. Only 1 case of acute bacterial endophthalmitis occurred, thus an incidence of 0.7% per shunt year. A slow-growing Mycobacterium was cultured in a disintegrating eye and 1 bacterial maxillary sinusitis occurred, both in autoimmune diseases. Three valves became exposed and had to be removed (1 replaced). Four eyes developed hypotony, probably from valve failure. The shunt arrangement, which connects the anterior chamber to potentially microbe-populated cavities or to the lower lid fornix and its flora, might be suspected to allow rapid retrograde invasion of infective agents, resulting in endophthalmitis. In this series of KPro patients, however, the incidence of severe infection was very low, in fact

  9. Graphene double-layer capacitor with ac line-filtering performance.

    Science.gov (United States)

    Miller, John R; Outlaw, R A; Holloway, B C

    2010-09-24

    Electric double-layer capacitors (DLCs) can have high storage capacity, but their porous electrodes cause them to perform like resistors in filter circuits that remove ripple from rectified direct current. We have demonstrated efficient filtering of 120-hertz current with DLCs with electrodes made from vertically oriented graphene nanosheets grown directly on metal current collectors. This design minimized electronic and ionic resistances and produced capacitors with RC time constants of less than 200 microseconds, in contrast with ~1 second for typical DLCs. Graphene nanosheets have a preponderance of exposed edge planes that greatly increases charge storage as compared with that of designs that rely on basal plane surfaces. Capacitors constructed with these electrodes could be smaller than the low-voltage aluminum electrolyte capacitors that are typically used in electronic devices.

  10. Graphene Double-Layer Capacitor with ac Line-Filtering Performance

    Science.gov (United States)

    Miller, John R.; Outlaw, R. A.; Holloway, B. C.

    2010-09-01

    Electric double-layer capacitors (DLCs) can have high storage capacity, but their porous electrodes cause them to perform like resistors in filter circuits that remove ripple from rectified direct current. We have demonstrated efficient filtering of 120-hertz current with DLCs with electrodes made from vertically oriented graphene nanosheets grown directly on metal current collectors. This design minimized electronic and ionic resistances and produced capacitors with RC time constants of less than 200 microseconds, in contrast with ~1 second for typical DLCs. Graphene nanosheets have a preponderance of exposed edge planes that greatly increases charge storage as compared with that of designs that rely on basal plane surfaces. Capacitors constructed with these electrodes could be smaller than the low-voltage aluminum electrolyte capacitors that are typically used in electronic devices.

  11. Catechol-chitosan redox capacitor for added amplification in electrochemical immunoanalysis.

    Science.gov (United States)

    Yan, Kun; Liu, Yi; Guan, Yongguang; Bhokisham, Narendranath; Tsao, Chen-Yu; Kim, Eunkyoung; Shi, Xiao-Wen; Wang, Qin; Bentley, William E; Payne, Gregory F

    2018-05-22

    Antibodies are common recognition elements for molecular detection but often the signals generated by their stoichiometric binding must be amplified to enhance sensitivity. Here, we report that an electrode coated with a catechol-chitosan redox capacitor can amplify the electrochemical signal generated from an alkaline phosphatase (AP) linked immunoassay. Specifically, the AP product p-aminophenol (PAP) undergoes redox-cycling in the redox capacitor to generate amplified oxidation currents. We estimate an 8-fold amplification associated with this redox-cycling in the capacitor (compared to detection by a bare electrode). Importantly, this capacitor-based amplification is generic and can be coupled to existing amplification approaches based on enzyme-linked catalysis or magnetic nanoparticle-based collection/concentration. Thus, the capacitor should enhance sensitivities in conventional immunoassays and also provide chemical to electrical signal transduction for emerging applications in molecular communication. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Problems of increasing specific characteristics of pulse capacitors and cables

    International Nuclear Information System (INIS)

    Kuchinskij, G.S.; Monastyrskij, A.E.; Shilin, O.V.

    1984-01-01

    Requirements for high specific energy are practically related to all types of pulse capacitors of energy storage. At present the specific energy for most types of home and foreign pulse capacitors is about 0.1 MJ/m 3 at operating electric field intensity 70-100 kV/mm. It is shown that the basic means for increasing the specific energy and working intensity is the application of new polymeric film materials. Application of paper-film and film insulation permits to develop the specific types of capacitors designed for a limited service life in an aperiodic discharge mode with lower reliabiliy and the specific energy upto 0.5 MJ/m 3 . Characteristics of separate types of pulse capacitors and cables are given, and reliability criterion is considered. Measures of increasing reliability and service life for pulse capacitors and cables, used as tokamak power supplies are enumerated

  13. Absorption Voltages and Insulation Resistance in Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander

    2016-01-01

    Time dependence of absorption voltages (Vabs) in different types of low-voltage X5R and X7R ceramic capacitors was monitored for a maximum duration of hundred hours after polarization. To evaluate the effect of mechanical defects on Vabs, cracks in the dielectric were introduced either mechanically or by thermal shock. The maximum absorption voltage, time to roll-off, and the rate of voltage decrease are shown to depend on the crack-related leakage currents and insulation resistance in the parts. A simple model that is based on the Dow equivalent circuit for capacitors with absorption has been developed to assess the insulation resistance of capacitors. Standard measurements of the insulation resistance, contrary to the measurements based on Vabs, are not sensitive to the presence of mechanical defects and fail to reveal capacitors with cracks. Index Terms: Ceramic capacitor, insulation resistance, dielectric absorption, cracking.

  14. The two-capacitor problem revisited: a mechanical harmonic oscillator model approach

    International Nuclear Information System (INIS)

    Lee, Keeyung

    2009-01-01

    The well-known two-capacitor problem, in which exactly half the stored energy disappears when a charged capacitor is connected to an identical capacitor, is discussed based on the mechanical harmonic oscillator model approach. In the mechanical harmonic oscillator model, it is shown first that exactly half the work done by a constant applied force is dissipated irrespective of the form of dissipation mechanism when the system comes to a new equilibrium after a constant force is abruptly applied. This model is then applied to the energy loss mechanism in the capacitor charging problem or the two-capacitor problem. This approach allows a simple explanation of the energy dissipation mechanism in these problems and shows that the dissipated energy should always be exactly half the supplied energy whether that is caused by the Joule heat or by the radiation. This paper, which provides a simple treatment of the energy dissipation mechanism in the two-capacitor problem, is suitable for all undergraduate levels

  15. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  16. Degradation Effect on Reliability Evaluation of Aluminum Electrolytic Capacitor in Backup Power Converter

    DEFF Research Database (Denmark)

    Zhou, Dao; Wang, Huai; Blaabjerg, Frede

    2017-01-01

    DC capacitors in power electronic converters are a major constraint on improvement of power density as well as reliability. In this paper, according to the degradation data of electrolytic capacitors through the accelerated test, the time-to-failure of the capacitor cell is acquired and it can...... be further extended to lower stress levels. Then, in a case study of a fuel cell backup power application, the mission profile based lifetime expectancy of the individual capacitor and the capacitor bank is estimated in terms of the standby mode and operation mode. The lifetime prediction of the capacitor...

  17. Superior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications

    Directory of Open Access Journals (Sweden)

    Neema Praveen

    2009-01-01

    Full Text Available Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.

  18. SOGI-based capacitor voltage feedback active damping in LCL-filtered grid converters

    DEFF Research Database (Denmark)

    Xin, Zhen; Wang, Xiongfei; Loh, Poh Chiang

    2015-01-01

    The capacitor voltage feedback active damping control is an attractive way to suppress LCL-filter resonance especially for the systems where the capacitor voltage is used for grid synchronization, since no extra sensors are added. The derivative is the core of the capacitor voltage feedback active...... derivative is more suited for capacitor voltage feedback active damping control. Experimental results validate the effectiveness of the proposed method....

  19. Optimization Based Shunt APF Controller to Mitigate Reactive Power, Burden of Neutral Conductor, Current Harmonics and Improve cosɸ

    Directory of Open Access Journals (Sweden)

    P. Anjana

    2017-03-01

    Full Text Available This paper presents a Modified Gravitational Search Algorithm (MGSA to improve the performance of PI controller in varying load condition. The proposed approach is capable of mitigating reactive power, neutral current, source current THD and significant improvement in power factor nearly unity (0.997. The DC link voltage across the capacitor is controlled by PI controller which is deciding the performance of shunt APF. Hence, the robust optimization technique based integral time square error (ITSE with consideration of weight factor (α & β, maximum overshoot ((|(∆_Ve ̅〖(n〗_max | and setling time t_s-t_0, is providing the optimum solution of Kp & Ki. The robustness of proposed objective function and algorithm compared with GSA based three other error criterion techniques. The efficiency of the proposed controller has been tested over nonlinear and unbalance loading condition. The performance of ITSE based MGSA-PI controller is batter then other three error criterion techniques. The values of THD are below the mark of 5% specified in IEEE-519 standard.

  20. Electrode/Dielectric Strip For High-Energy-Density Capacitor

    Science.gov (United States)

    Yen, Shiao-Ping S.

    1994-01-01

    Improved unitary electrode/dielectric strip serves as winding in high-energy-density capacitor in pulsed power supply. Offers combination of qualities essential for high energy density: high permittivity of dielectric layers, thinness, and high resistance to breakdown of dielectric at high electric fields. Capacitors with strip material not impregnated with liquid.

  1. Reliability of Capacitors for DC-Link Applications in Power Electronic Converters

    DEFF Research Database (Denmark)

    Wang, Huai; Blaabjerg, Frede

    2014-01-01

    DC-link capacitors are an important part in the majority of power electronic converters which contribute to cost, size and failure rate on a considerable scale. From capacitor users' viewpoint, this paper presents a review on the improvement of reliability of dc link in power electronic converters...... from two aspects: 1) reliability-oriented dc-link design solutions; 2) conditioning monitoring of dc-link capacitors during operation. Failure mechanisms, failure modes and lifetime models of capacitors suitable for the applications are also discussed as a basis to understand the physics......-of-failure. This review serves to provide a clear picture of the state-of-the-art research in this area and to identify the corresponding challenges and future research directions for capacitors and their dc-link applications....

  2. Ventriculoperitoneal shunt-related infections caused by Staphylococcus epidermidis: pathogenesis and implications for treatment.

    LENUS (Irish Health Repository)

    Stevens, Niall T

    2012-12-01

    The insertion of medical devices, such as intraventricular shunts, is often complicated by infection leading to ventriculitis. Frequently, such infections result from colonisation and subsequent biofilm formation on the surfaces of the shunts by Staphylococcus epidermidis. The pathogenesis of neurosurgical shunt-related infection is complex with interactions between the pathogen, the device and the unique local immunological environment of the central nervous system (CNS). An ability to form biofilm, the main virulence determinant of Staphylococcus epidermidis, facilitates protection of the organism from the host defences while still initiating an immunological response. The presence of the blood brain barrier (BBB) and the biofilm itself also complicates treatment, which presents many challenges when managing shunt infections. A greater understanding of the interplay between S. epidermidis and the CNS could potentially improve the diagnosis, treatment and management of such infections. This review describes the pathogenesis, treatment and implications of S. epidermidis ventriculoperitoneal shunt-related infections, concentrating on recent research and the implications for treatment.

  3. Design of the individual Marx modules for the Atlas machine 36 megajoule, 25 megampere capacitor bank

    International Nuclear Information System (INIS)

    Reass, W.A.; Bowman, D.W.; Gribble, R.F.; Griego, J.R.; Thompson, C.; Parsons, W.M.

    1995-01-01

    This paper presents the preliminary electrical and mechanical design of the Atlas machine's 1.8 megajoule, 600 kV Marx modules. The modules are implemented with plastic cased capacitors similar to those developed for the Defense Nuclear Agency (DNA) ACE II and ACE IV machines. The double ended electrode capacitor style has been dubbed ''FASTCAP.'' Electrodes are provided for mounting rail-gaps on one side and flat plate transmission line damping resistors on the other. This provides for an extremely low circuit inductance. A series array of ten capacitors, each rated at 60 kV, 33.5 uF, and 60 kJ, with their five triggered rail-gaps, form a Marx submodule. Three Marx submodules are nested into a large G-10 fiberglass rack to form a complete Marx module. The module support rack has individual capacitor shelves that ease assembly and replacement. The Marx's design also facilitates construction, testing and verification of a modules performance prior to installation. Modules will be repaired or maintained in a separate test bay without affecting machine operation schedules. Railgap maintenance will become part of a regularly-scheduled preventative maintenance program as spare modules are installed and removed from the machine

  4. Study on epoxy/BaTiO3 composite embedded capacitor films (ECFs) for organic substrate applications

    International Nuclear Information System (INIS)

    Cho, Sung-Dong; Lee, Joo-Yeon; Hyun, Jin-Gul; Paik, Kyung-Wook

    2004-01-01

    Embedded capacitor films (ECFs) were newly designed for high dielectric constant and low capacitance tolerance (less than ±5%) embedded capacitor fabrication for organic substrates. ECFs are transferable and B-stage films which can be coated on a releasing film. In terms of materials formulation, ECFs are composed of high dielectric constant BaTiO 3 (BT) powder, specially formulated epoxy resin, and latent curing agent. And in terms of coating process, a roll coating method is used for obtaining film thickness uniformity in a large area. Differential scanning calorimeter (DSC) thermal analysis was conducted to determine the optimum amount of curing agent, curing temperature, and curing time. Changes in the dielectric constant of epoxy/BaTiO 3 composite ECFs with BT particle sizes and contents were investigated. Dielectric constant of 90 was obtained using two different size BaTiO 3 powders mixture. Typically, capacitors of 12 μm thick film with 8 nF/cm 2 with less than ±5% capacitance tolerance and low leakage current (less than 10 -7 A/cm 2 at 10 V) were successfully demonstrated on PCBs using epoxy/BaTiO 3 composite embedded capacitor films

  5. Design strategy for the combined system of shunt passive and series active filters

    OpenAIRE

    Fujita, Hideki; Akagi, Hirofumi

    1991-01-01

    A design strategy for the combined power filter for a three-phase twelve-pulse thyristor rectifier is proposed. The shunt passive filter, which can minimize the output voltage of the series active filter, is designed and tested in a prototype model. A specially designed shunt passive filter makes it possible to reduce the required rating of the series active filter to 60% compared with a conventional shunt passive filter

  6. Two cases of esophageal cancer with portal hypertension: esophagectomy with venous shunt procedure.

    Science.gov (United States)

    Kato, T; Motohara, T; Kaneko, Y; Shikishima, H; Okushiba, S; Kondo, S; Kato, H

    2001-01-01

    We performed venous shunt procedure in the reconstruction of the esophagus after esophagectomy using the gastric tube in two cases of esophageal cancer with portal hypertension due to liver cirrhosis. In both cases, the short-term postoperative course was uneventful, without congestion in the gastric tube. In Case 1 where the short gastric vein had been used as the shunt vein, the long-term postoperative course was also uneventful, without hepatic encephalopathy or hemorrhage from deterioration of the varices of the gastric tube. However, in Case 2 where the left gastroepiploic vein had been used, hepatic encephalopathy developed due to excessive shunt flow. These results suggested that appropriate shunt flow could be expected by using short gastric vein.

  7. Breakdown properties of irradiated MOS capacitors

    International Nuclear Information System (INIS)

    Paccagnella, A.; Candelori, A.; Pellizzer, F.; Fuochi, P.G.; Lavale, M.

    1996-01-01

    The authors have studied the effects of ionizing and non-ionizing radiation on the breakdown properties of different types of MOS capacitors, with thick (200 nm) and thin (down to 8 nm) oxides. In general, no large variations of the average breakdown field, time-to-breakdown at constant voltage, or charge-to-breakdown at constant voltage, or charge-to-breakdown values have been observed after high dose irradiation (20 Mrad(Si) 9 MeV electrons on thin and thick oxides, 17(Si) Mrad Co 60 gamma and 10 14 neutrons/cm 2 only on thick oxides). However, some modifications of the cumulative failure distributions have been observed in few of the oxides tested

  8. Single ICCII Sinusoidal Oscillators Employing Grounded Capacitors

    Directory of Open Access Journals (Sweden)

    J. W. Horng

    2011-09-01

    Full Text Available Two inverting second-generation current conveyors (ICCII based sinusoidal oscillators are presented. The first sinusoidal oscillator is composed of one ICCII, two grounded capacitors and two resistors. The oscillation condition and oscillation frequency can be orthogonally controllable. The second sinusoidal oscillator is composed of one ICCII, two grounded capacitors and three resistors. The oscillation condition and oscillation frequency can be independently controllable through different resistors.

  9. Impedance measurement and modelling of super-capacitors for railway applications

    Energy Technology Data Exchange (ETDEWEB)

    Hammar, A.; Chabas, J. [Societe Nationale des Chemins de fer Francais (SNCF), Dir. de la Recherche, 75 - Paris (France); Coquery, G.; Lallemand, R. [Institut National de Recherche sur les Transports et leur Securite (INRETS), Lab. des Technologies Nouvelles, 94 - Arcueil (France); Rojat, G.; Venet, P. [Lyon-1 Univ. Claude Bernard, CEGELY, 69 - Villeurbanne (France)

    2004-07-01

    Railways and electrical traction systems require high power rates to achieve their operating performances. Systems of power supply based on super-capacitors should offer high power density along with good energy efficiency and expected operating safety. We investigate general behaviours of super-capacitors with two powerful methods of analysis. The first is constant charge/discharge current at high level value (500 A), the second is impedance spectroscopy which leads to the acquisition of a set of parameters that are considered sufficient to describe general properties of super-capacitor, in particular the state of health and the available energy in any operating conditions. An electrical circuit model is defined for super-capacitors based on activated carbon and organic electrolyte. It takes into account the dependence of super-capacitor to voltage and current. The mixture of data of the two methods permits to obtain a representative model for power applications. Matlab/Simulink simulations are shown to verify the validity of the model. (authors)

  10. Reduction of shunt obstructions by using a peel-away sheath technique? A multicenter prospective randomized trial.

    Science.gov (United States)

    Kehler, Uwe; Langer, Niels; Gliemroth, Jan; Meier, Ullrich; Lemcke, Johannes; Sprung, Christian; Schlosser, Hans-Georg; Kiefer, Michael; Eymann, Regina; Heese, Oliver

    2012-05-01

    Shunt obstructions may partly be caused by brain debris, which intrude into the ventricular catheter during ventricle puncture. Avoiding contact between the catheter and brain tissue, by using a peel-away sheath, should reduce the number of shunt failures caused by obstruction. To test this hypothesis, we conducted a randomized, prospective multicenter study. 201 patients from 6 different neurosurgical centers in Germany receiving a ventriculo-peritoneal shunt were included in this study. Of these, 177 patients completed a 1-year follow-up period. Surgery was randomized in a 1 to 1 fashion, such that out of 177 procedures, 91 were performed using a peel-away sheath and 86 were performed without. The rate of surgical re-interventions and shunt obstructions within a 12-month period was recorded. Within 1 year post-surgery, 17 shunt obstructions (9.6%) leading to shunt revisions were recorded. However, no difference was found between surgeries performed using a peel-away sheath (9.9%) or not (9.3%). The overall shunt infection rate was 2.8% and the shunt revision rate for overdrainage was 3.9%. The theoretical advantages attributed to the use of a peel-away sheath to introduce a ventricular catheter could not be confirmed in this randomized study, suggesting that the proposed role of brain debris in shunt obstructions may be overestimated. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Capacitor Bank 'CHANDI' for Plasma Target Production for Liner Plasma Interaction

    International Nuclear Information System (INIS)

    Shukla, R.; Sharma, S.K.; Debnath, K.; Shyam, A.

    2006-01-01

    A capacitor bank is fabricated to drive (JXB) Plasma gun to generate hot plasma (target) for liner plasma investigation. The bank will also be used for driving other pintch experiments. The bank consists of 8 capacitors connected in parallel, each having capacitance of 178 μF giving a total of 1424uF. The bank is charged at 15 kV using a 28 kV power supply charging the capacitors in 65 seconds utilizing full wave charging technique. The total energy of the bank is 160kJ at 15kV. A modeling of power supply was done so that all the components involved are utilized to their operating limit safely. Moreover to give fault protection to the capacitor bank we have implemented the neutral control technique in the power supply. The capacitor bank is discharged to the inductive load through an ignitron switch of very high coulomb rating and capable of withstanding high voltages at its electrodes. The cables used for connecting capacitor bank with ignitron switch are used in parallel to give them collective capability of bearing capacitor discharge currents. These cables are capable of holding high DC voltages (40kV), which appear at the time of charging of the bank. The bank is tested and is operational

  12. Antenna Miniaturization with MEMS Tunable Capacitors

    DEFF Research Database (Denmark)

    Barrio, Samantha Caporal Del; Morris, Art; Pedersen, Gert Frølund

    2014-01-01

    In today’s mobile device market, there is a strong need for efficient antenna miniaturization. Tunable antennas are a very promising way to reduce antenna volume while enlarging its operating bandwidth. MEMS tunable capacitors are state-ofthe- art in terms of insertion loss and their characterist......In today’s mobile device market, there is a strong need for efficient antenna miniaturization. Tunable antennas are a very promising way to reduce antenna volume while enlarging its operating bandwidth. MEMS tunable capacitors are state-ofthe- art in terms of insertion loss...

  13. 21 CFR 882.5550 - Central nervous system fluid shunt and components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Central nervous system fluid shunt and components... Central nervous system fluid shunt and components. (a) Identification. A central nervous system fluid... central nervous system to an internal delivery site or an external receptacle for the purpose of relieving...

  14. A Robust DC-Split-Capacitor Power Decoupling Scheme for Single-Phase Converter

    DEFF Research Database (Denmark)

    Yao, Wenli; Loh, Poh Chiang; Tang, Yi

    2017-01-01

    Instead of bulky electrolytic capacitors, active power decoupling circuit can be introduced to a single-phase converter for diverting second harmonic ripple away from its dc source or load. One possible circuit consists of a half-bridge and two capacitors in series for forming a dc-split capacitor......, instead of the usual single dc-link capacitor bank. Methods for regulating this power decoupler have earlier been developed, but almost always with equal capacitances assumed for forming the dc-split capacitor, even though it is not realistic in practice. The assumption should, hence, be evaluated more...... thoroughly, especially when it is shown in the paper that even a slight mismatch can render the power decoupling scheme ineffective and the IEEE 1547 standard to be breached. A more robust compensation scheme is, thus, needed for the dc-split capacitor circuit, as proposed and tested experimentally...

  15. Instantaneous thermal modeling of the DC-link capacitor in PhotoVoltaic systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Ma, Ke; Wang, Huai

    2015-01-01

    , instantaneous thermal modeling approaches considering mission profiles for the DC-link capacitor in single-phase PV systems are explored in this paper. These thermal modelling approaches are based on: a) fast Fourier transform, b) look-up tables, and c) ripple current reconstruction. Moreover, the thermal...... grid-connected PV system have been adopted to demonstrate a look-up table based modelling approach, where real-field daily ambient conditions are considered....... modelling approaches for the DC-link capacitors take into account the instantaneous thermal characteristics, which are more challenging to the capacitor reliability during operation. Such instantaneous thermal modeling approaches enable a translation of instantaneous capacitor power losses to capacitor...

  16. Nanodomain Engineering in Ferroelectric Capacitors with Graphene Electrodes.

    Science.gov (United States)

    Lu, Haidong; Wang, Bo; Li, Tao; Lipatov, Alexey; Lee, Hyungwoo; Rajapitamahuni, Anil; Xu, Ruijuan; Hong, Xia; Farokhipoor, Saeedeh; Martin, Lane W; Eom, Chang-Beom; Chen, Long-Qing; Sinitskii, Alexander; Gruverman, Alexei

    2016-10-12

    Polarization switching in ferroelectric capacitors is typically realized by application of an electrical bias to the capacitor electrodes and occurs via a complex process of domain structure reorganization. As the domain evolution in real devices is governed by the distribution of the nucleation centers, obtaining a domain structure of a desired configuration by electrical pulsing is challenging, if not impossible. Recent discovery of polarization reversal via the flexoelectric effect has opened a possibility for deterministic control of polarization in ferroelectric capacitors. In this paper, we demonstrate mechanical writing of arbitrary-shaped nanoscale domains in thin-film ferroelectric capacitors with graphene electrodes facilitated by a strain gradient induced by a tip of an atomic force microscope (AFM). A phase-field modeling prediction of a strong effect of graphene thickness on the threshold load required to initiate mechanical switching has been confirmed experimentally. Deliberate voltage-free domain writing represents a viable approach for development of functional devices based on domain topology and electronic properties of the domains and domain walls.

  17. The Two-Capacitor Problem Revisited: A Mechanical Harmonic Oscillator Model Approach

    Science.gov (United States)

    Lee, Keeyung

    2009-01-01

    The well-known two-capacitor problem, in which exactly half the stored energy disappears when a charged capacitor is connected to an identical capacitor, is discussed based on the mechanical harmonic oscillator model approach. In the mechanical harmonic oscillator model, it is shown first that "exactly half" the work done by a constant applied…

  18. Laparoscopic assisted ventriculoperitoneal shunt revisions as an option for pediatric patients with previous intraabdominal complications

    Directory of Open Access Journals (Sweden)

    Fernanda O. de Carvalho

    2014-04-01

    Full Text Available Multiple shunt failure is a challenge in pediatric neurosurgery practice and one of the most feared complications of hydrocephalus. Objective: To demonstrate that laparoscopic procedures for distal ventriculoperitoneal shunt failure may be an effective option for patients who underwent multiple revisions due to repetitive manipulation of the peritoneal cavity, abdominal pseudocyst, peritonitis or other situations leading to a “non reliable” peritoneum. Method: From March 2012 to February 2013, the authors reviewed retrospectively the charts of six patients born and followed up at our institution, which presented with previous intra-peritoneal complications and underwent ventriculoperitoneal shunt revision assisted by video laparoscopy. Results: After a mean follow-up period of nine months, all patients are well and no further shunt failure was identified so far. Conclusion: Laparoscopy assisted shunt revision in children may be, in selected cases, an effective option for patients with multiple peritoneal complications due to ventriculo-peritoneal shunting.

  19. Reliability assessment for metallized film pulse capacitors with accelerated degradation test

    International Nuclear Information System (INIS)

    Zhao Jianyin; Liu Fang; Xi Wenjun; He Shaobo; Wei Xiaofeng

    2011-01-01

    The high energy density self-healing metallized film pulse capacitor has been applied to all kinds of laser facilities for their power conditioning systems, whose reliability is straightforward affected by the reliability level of capacitors. Reliability analysis of highly reliable devices, such as metallized film capacitors, is a challenge due to cost and time restriction. Accelerated degradation test provides a way to predict its life cost and time effectively. A model and analyses for accelerated degradation data of metallized film capacitors are described. Also described is a method for estimating the distribution of failure time. The estimation values of the unknown parameters in this model are 9.066 9 x 10 -8 and 0.022 1. Both the failure probability density function (PDF) and the cumulative distribution function (CDF) can be presented by this degradation failure model. Based on these estimation values and the PDF/CDF, the reliability model of the metallized film capacitors is obtained. According to the reliability model, the probability of the capacitors surviving to 20 000 shot is 0.972 4. (authors)

  20. Endoscopic third ventriculostomy versus ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Patients' medical records, operative notes, and neural tube database records were used to complete a structured questionnaire. The difference in ... likely after 6 months. Keywords: obstructive hydrocephalus; endoscopic third ventriculostomy; ventriculoperitoneal shunt; children; paediatric surgery; neurosurgery; Ethiopia ...

  1. Characterization system for research on energy storage capacitors

    Science.gov (United States)

    Noriega, J. R.; Iyore, O. D.; Budime, C.; Gnade, B.; Vasselli, J.

    2013-05-01

    In this work a characterization system for high energy-density capacitors is described and demonstrated. Capacitors are being designed using thin-film technology in an attempt to achieve higher energy-density levels by operating the devices at a high voltage. These devices are fabricated from layers of 100 nm aluminum and a layer of polyvinylidene fluoride-hexafluoropropylene on a polyethylene naphthalate plastic substrate. The devices have been designed to store electrical charge at up to 200 V. Characterizations of these devices focus on the measurement of capacitance vs bias voltage and temperature, equivalent series resistance, and charge/discharge cycles. For the purpose of the characterization of these capacitors, an electronic charge/discharge interface was designed and tested.

  2. Ferroelectric and piezoelectric thin films and their applications for integrated capacitors, piezoelectric ultrasound transducers and piezoelectric switches

    International Nuclear Information System (INIS)

    Klee, M; Boots, H; Kumar, B; Heesch, C van; Mauczok, R; Keur, W; Wild, M de; Esch, H van; Roest, A L; Reimann, K; Leuken, L van; Wunnicke, O; Zhao, J; Schmitz, G; Mienkina, M; Mleczko, M; Tiggelman, M

    2010-01-01

    Ferroelectric and piezoelectric thin films are gaining more and more importance for the integration of high performance devices in small modules. High-K 'Integrated Discretes' devices have been developed, which are based on thin film ferroelectric capacitors integrated together with resistors and ESD protection diodes in a small Si-based chip-scale package. Making use of ferroelectric thin films with relative permittivity of 950-1600 and stacking processes of capacitors, extremely high capacitance densities of 20-520 nF/mm 2 , high breakdown voltages up to 140 V and lifetimes of more than 10 years at operating voltages of 5 V and 85 deg. C are achieved. Thin film high-density capacitors play also an important role as tunable capacitors for applications such as tuneable matching circuits for RF sections of mobile phones. The performance of thin film tuneable capacitors at frequencies between 1 MHz and 1 GHz is investigated. Finally thin film piezoelectric ultrasound transducers, processed in Si- related processes, are attractive for medical imaging, since they enable large bandwidth (>100%), high frequency operation and have the potential to integrate electronics. With these piezoelectric thin film ultrasound transducers real time ultrasound images have been realized. Finally, piezoelectric thin films are used to manufacture galvanic MEMS switches. A model for the quasi-static mechanical behaviour is presented and compared with measurements.

  3. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  4. Two-layer radio frequency MEMS fractal capacitors in PolyMUMPS for S-band applications

    KAUST Repository

    Elshurafa, Amro M.

    2012-07-23

    In this Letter, the authors fabricate for the first time MEMS fractal capacitors possessing two layers and compare their performance characteristics with the conventional parallel-plate capacitor and previously reported state-of-the-art single-layer MEMS fractal capacitors. Explicitly, a capacitor with a woven structure and another with an interleaved configuration were fabricated in the standard PolyMUMPS surface micromachining process and tested at S-band frequencies. The self-resonant frequencies of the fabricated capacitors were close to 10GHz, which is better than that of the parallel-plate capacitor, which measured only 5.5GHz. Further, the presented capacitors provided a higher capacitance when compared with the state-of-the-art-reported MEMS fractal capacitors created using a single layer at the expense of a lower quality factor. © 2012 The Institution of Engineering and Technology.

  5. Correlation of experimental rCBF determinations in goats with flow measurements from a Doppler-modified carotid artery shunt

    International Nuclear Information System (INIS)

    Loftus, C.M.; Silvidi, J.A.; Becker, J.A.; Miller, B.V.; Bernstein, D.D.

    1989-01-01

    A carotid artery shunt system has been developed that continuously monitors blood flow rates by embedding a Doppler crystal in the shunt wall. The crystal ranges through a liquid lens that enables it to be placed without violation of the shunt lumen. Because the crystal is at a fixed angle (45 degrees) to the axis of blood flow and the diameter of the lumen remains constant, a linear relationship exists between flow rates and the Doppler velocity signal. This shunt system was previously tested in vitro using a pulsatile pump and was found to be accurate to within 4.7% of the actual flow rate. In the present study, animal (goat) experiments were performed consisting of simultaneous carotid shunt flow and bilateral rCBF measurements by the radiolabeled microsphere technique to determine in vivo the accuracy of this Doppler modified shunt and to ascertain the ability of shunt flow to increase in the face of acute contralateral carotid occlusion. Data from five animals show that in vivo shunt flow can be recorded to within 13% of control rCBF and that shunt flow increases nearly 50% under conditions of distal demand (contralateral carotid occlusion). This device may prove useful in laboratory studies of carotid shunt dynamics and in clinical practice to quickly detect correctable shunt flow abnormalities

  6. Treatment of hydrocephalus associated with neurosarcoidosis by multiple shunt placement.

    Science.gov (United States)

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-09-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showed an isolated fourth ventricle with both the inlet and outlet of fourth ventricle obstructed by recurrent neurosarcoidosis. Owing to the difficulty of using an endoscope, we performed neuronavigator-guided ventriculo-peritoneal shunting via the left lateral transcerebellar approach for the treatment of the isolated fourth ventricle with intravenous methyl prednisolone. The patient was discharged with improved neurological status.

  7. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions.

    Science.gov (United States)

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH 2 O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was -3.69±19.20 mmH 2 O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH 2 O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH 2 O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant ( p =0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Under-drainage of CSF should be suspected if CSF lumbar tapping

  8. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    Science.gov (United States)

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  9. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    International Nuclear Information System (INIS)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S.

    2003-01-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus

  10. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S. [College of Medicine, Univ. of Inhwa, Incheon (Korea, Republic of)

    2003-07-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus.

  11. Highly Accurate Derivatives for LCL-Filtered Grid Converter with Capacitor Voltage Active Damping

    DEFF Research Database (Denmark)

    Xin, Zhen; Loh, Poh Chiang; Wang, Xiongfei

    2016-01-01

    The middle capacitor voltage of an LCL-filter, if fed back for synchronization, can be used for active damping. An extra sensor for measuring the capacitor current is then avoided. Relating the capacitor voltage to existing popular damping techniques designed with capacitor current feedback would...... are then proposed, based on either second-order or non-ideal generalized integrator. Performances of these derivatives have been found to match the ideal “s” function closely. Active damping based on capacitor voltage feedback can therefore be realized accurately. Experimental results presented have verified...

  12. Staphylococcus warneri ventriculoperitoneal shunt infection: failure of diagnosis by ventricular CSF sampling.

    Science.gov (United States)

    Martínez-Lage, Juan F; Martínez-Lage Azorín, Laura; Almagro, María-José

    2010-12-01

    The definite diagnosis of hydrocephalus valve infection is generally made by cerebrospinal fluid (CSF) sampling via the valve reservoir, which is considered to be more dependable than that of the CSF obtained by lumbar puncture. We treated a 17-year-old boy with an intra-abdominal pseudocyst due to ventriculoperitoneal shunt infection caused by Staphylococcus warneri whose ventricular CSF, obtained via the valve reservoir, was repeatedly sterile thus causing a considerable delay in the management of the complication. S. warneri constitutes an emergent contaminant of catheters and prostheses. We found only a detailed report of S. warneri infection of a ventriculoatrial shunt. If manifestations of peritoneal involvement in shunted patients would occur, the attention should be shifted to the distal component of the shunt hardware, even in the presence of a normal ventricular CSF as happened in our case to avoid unnecessary delay in diagnosis and management.

  13. Manipulating waves by distilling frequencies: a tunable shunt-enabled rainbow trap

    Science.gov (United States)

    Cardella, Davide; Celli, Paolo; Gonella, Stefano

    2016-08-01

    In this work, we propose and test a strategy for tunable, broadband wave attenuation in electromechanical waveguides with shunted piezoelectric inclusions. Our strategy is built upon the vast pre-existing literature on vibration attenuation and bandgap generation in structures featuring periodic arrays of piezo patches, but distinguishes itself for several key features. First, we demystify the idea that periodicity is a requirement for wave attenuation and bandgap formation. We further embrace the idea of ‘organized disorder’ by tuning the circuits as to resonate at distinct neighboring frequencies. In doing so, we create a tunable ‘rainbow trap’ (Tsakmakidis et al 2007 Nature 450 397-401) capable of attenuating waves with broadband characteristics, by distilling (sequentially) seven frequencies from a traveling wavepacket. Finally, we devote considerable attention to the implications in terms of packet distortion of the spectral manipulation introduced by shunting. This work is also meant to serve as a didactic tool for those approaching the field of shunted piezoelectrics, and attempts to provide a different perspective, with abundant details, on how to successfully design an experimental setup involving resistive-inductive shunts.

  14. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    2008-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  15. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; Roozeboom, F.; Reefman, D.; Ruigrok, J.

    2013-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  16. Floating body cell a novel capacitor-less DRAM cell

    CERN Document Server

    Ohsawa, Takashi

    2011-01-01

    DRAM together with NAND Flash is driving semiconductor technologies with wide spectrum of usage ranging from PC, mobile phone and digital home appliances to solid-state disk (SSD). However, the DRAM cell which consists of a data storage capacitor (1C) and a switching transistor (1T) is facing serious difficulty in shrinking the size of the capacitor whose capacitance needs to be kept almost constant (20~30fF) throughout generations. The availability of a new DRAM cell which does not rely on an explicit capacitor for storing its data is more than ever awaited for further increasing the bit dens

  17. Investigation of embedded perovskite nanoparticles for enhanced capacitor permittivities.

    Science.gov (United States)

    Krause, Andreas; Weber, Walter M; Pohl, Darius; Rellinghaus, Bernd; Verheijen, Marcel; Mikolajick, Thomas

    2014-11-26

    Growth experiments show significant differences in the crystallization of ultrathin CaTiO3 layers on polycrystalline Pt surfaces. While the deposition of ultrathin layers below crystallization temperature inhibits the full layer crystallization, local epitaxial growth of CaTiO3 crystals on top of specific oriented Pt crystals occurs. The result is a formation of crystals embedded in an amorphous matrix. An epitaxial alignment of the cubic CaTiO3 ⟨111⟩ direction on top of the underlying Pt {111} surface has been observed. A reduced forming energy is attributed to an interplay of surface energies at the {111} interface of both materials and CaTiO3 nanocrystallites facets. The preferential texturing of CaTiO3 layers on top of Pt has been used in the preparation of ultrathin metal-insulator-metal capacitors with 5-30 nm oxide thickness. The effective CaTiO3 permittivity in the capacitor stack increases to 55 compared to capacitors with amorphous layers and a permittivity of 28. The isolated CaTiO3 crystals exhibit a passivation of the CaTiO3 grain surfaces by the surrounding amorphous matrix, which keeps the capacitor leakage current at ideally low values comparable for those of amorphous thin film capacitors.

  18. Impact of cerebrospinal fluid shunting for idiopathic normal pressure hydrocephalus on the amyloid cascade.

    Directory of Open Access Journals (Sweden)

    Masao Moriya

    Full Text Available The aim of this study was to determine whether the improvement of cerebrospinal fluid (CSF flow dynamics by CSF shunting, can suppress the oligomerization of amyloid β-peptide (Aβ, by measuring the levels of Alzheimer's disease (AD-related proteins in the CSF before and after lumboperitoneal shunting. Lumbar CSF from 32 patients with idiopathic normal pressure hydrocephalus (iNPH (samples were obtained before and 1 year after shunting, 15 patients with AD, and 12 normal controls was analyzed for AD-related proteins and APLP1-derived Aβ-like peptides (APL1β (a surrogate marker for Aβ. We found that before shunting, individuals with iNPH had significantly lower levels of soluble amyloid precursor proteins (sAPP and Aβ38 compared to patients with AD and normal controls. We divided the patients with iNPH into patients with favorable (improvement ≥ 1 on the modified Rankin Scale and unfavorable (no improvement on the modified Rankin Scale outcomes. Compared to the unfavorable outcome group, the favorable outcome group showed significant increases in Aβ38, 40, 42, and phosphorylated-tau levels after shunting. In contrast, there were no significant changes in the levels of APL1β25, 27, and 28 after shunting. After shunting, we observed positive correlations between sAPPα and sAPPβ, Aβ38 and 42, and APL1β25 and 28, with shifts from sAPPβ to sAPPα, from APL1β28 to 25, and from Aβ42 to 38 in all patients with iNPH. Our results suggest that Aβ production remained unchanged by the shunt procedure because the levels of sAPP and APL1β were unchanged. Moreover, the shift of Aβ from oligomer to monomer due to the shift of Aβ42 (easy to aggregate to Aβ38 (difficult to aggregate, and the improvement of interstitial-fluid flow, could lead to increased Aβ levels in the CSF. Our findings suggest that the shunting procedure can delay intracerebral deposition of Aβ in patients with iNPH.

  19. Treatment of extrahepatic portal hypertension following a whipple procedure with a Rex shunt: report of a case.

    Science.gov (United States)

    Reichman, Trevor W; Anthony, Tiffany; Testa, Giuliano

    2011-02-01

    The Rex shunt is a mesenteric vein to left portal vein decompressive shunt used for the treatment of portal vein thrombosis and portal hypertension. Its use has been reported primarily in the pediatric population where portal vein thrombosis occurs with some frequency. The shunt is thought to represent a more physiologic shunt, since it restores hepatopedal blood flow through the liver. This report describes the use of this shunt in an adult who had frequent gastrointestinal bleeding secondary to extrahepatic portal vein thrombosis, which occurred as a complication after a pancreaticoduodenectomy.

  20. Carbon-based fibrous EDLC capacitors and supercapacitors

    OpenAIRE

    Lekakou, C; Moudam, O; Markoulidis, F; Andrews, T; Watts, JF; Reed, GT

    2011-01-01

    This paper investigates electrochemical double-layer capacitors (EDLCs) including two alternative types of carbon-based fibrous electrodes, a carbon fibre woven fabric (CWF) and a multiwall carbon nanotube (CNT) electrode, as well as hybrid CWF-CNT electrodes. Two types of separator membranes were also considered. An organic gel electrolyte PEO-LiCIO4-EC-THF was used to maintain a high working voltage. The capacitor cells were tested in cyclic voltammetry, charge-discharge, and impedance test...

  1. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  2. Downhole transmission system comprising a coaxial capacitor

    Science.gov (United States)

    Hall, David R [Provo, UT; Pixton, David S [Lehi, UT; Johnson, Monte L [Orem, UT; Bartholomew, David B [Springville, UT; Hall, Jr., H. Tracy; Rawle, Michael [Springville, UT

    2011-05-24

    A transmission system in a downhole component comprises a plurality of data transmission elements. A coaxial cable having an inner conductor and an outer conductor is disposed within a passage in the downhole component such that at least one capacitor is disposed in the passage and having a first terminal coupled to the inner conductor and a second terminal coupled to the outer conductor. Preferably the transmission element comprises an electrically conducting coil. Preferably, within the passage a connector is adapted to electrically connect the inner conductor of the coaxial cable and the lead wire. The coaxial capacitor may be disposed between and in electrically communication with the connector and the passage. In another embodiment a connector is adapted to electrical connect a first and a second portion of the inner conductor of the coaxial cable and a coaxial capacitor is in electrical communication with the connector and the passage.

  3. Powder based superdielectric materials for novel Capacitor design

    Science.gov (United States)

    2017-06-01

    found in cars, smartphones and other devices have adequate energy densities but lack optimal electric power delivery performance [4]. Stated differently... physical damage to the electrodes [5]. Conversely, capacitors store energy electrostatically by releasing excited state electrons collected on a...overview of capacitor theory is presented as a means of highlighting key physics principles applicable to this research. First, the concept of

  4. Tunable elastic parity-time symmetric structure based on the shunted piezoelectric materials

    Science.gov (United States)

    Hou, Zhilin; Assouar, Badreddine

    2018-02-01

    We theoretically and numerically report on the tunable elastic Parity-Time (PT) symmetric structure based on shunted piezoelectric units. We show that the elastic loss and gain can be archived in piezoelectric materials when they are shunted by external circuits containing positive and negative resistances. We present and discuss, as an example, the strongly dependent relationship between the exceptional points of a three-layered system and the impedance of their external shunted circuit. The achieved results evidence that the PT symmetric structures based on this proposed concept can actively be tuned without any change of their geometric configurations.

  5. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  6. Ventriculoperitoneal shunt for treatment of hydrocephalus in a French bulldog puppy

    Science.gov (United States)

    Giacinti, Jolene A.

    2016-01-01

    A 6.5-week-old bulldog was presented with lethargy, anorexia, and stunted growth. A domed skull, ventrolateral strabismus, hypermetria, and delayed hopping were observed. Congenital hydrocephalus was diagnosed and a ventriculoperitoneal shunt was placed. After surgery, a shunt obstruction occurred but resolved with treatment. The puppy responded well and neurological deficits continued to improve after surgery. PMID:26933271

  7. Isolation and characterization of Salmonella typhimurium glyoxylate shunt mutants.

    OpenAIRE

    Wilson, R B; Maloy, S R

    1987-01-01

    Growth of Salmonella typhimurium on acetate as a sole carbon source requires expression of the glyoxylate shunt; however, the genes for the glyoxylate shunt enzymes have not been previously identified in S. typhimurium. In this study, we isolated transposon insertions in the genes for the two unique enzymes of this pathway, aceA (isocitrate lyase) and aceB (malate synthase). The aceA and aceB genes were located at 89.5 min on the S. typhimurium genetic map. Genetic linkage to nearby loci indi...

  8. The application of structural nonlinearity in the development of linearly tunable MEMS capacitors

    International Nuclear Information System (INIS)

    Shavezipur, M; Khajepour, A; Hashemi, S M

    2008-01-01

    Electrostatically actuated parallel-plate tunable capacitors are the most desired MEMS capacitors because of their smaller sizes and higher Q-factors. However, these capacitors suffer from low tunability and exhibit high sensitivity near the pull-in voltage which counters the concept of tunability. In this paper, a novel design for parallel-plate tunable capacitors with high tunability and linear capacitance–voltage (C–V) response is developed. The design uses nonlinear structural rigidities to relieve intrinsic electrostatic nonlinearity in MEMS capacitors. Based on the force–displacement characteristic of an ideally linear capacitor, a real beam-like nonlinear spring model is developed. The variable stiffness coefficients of such springs improve the linearity of the C–V curve. Moreover, because the structural stiffness increases with deformations, the pull-in is delayed and higher tunability is achieved. Finite element simulations reveal that capacitors with air gaps larger than 4 µm and supporting beams thinner than 1 µm can generate highly linear C–V responses and tunabilities over 120%. Experimental results for capacitors fabricated by PolyMUMPs verify the effect of weak nonlinear geometric stiffness on improving the tunability for designs with a small air gap and relatively thick structural layers

  9. Impedance Characteristics Modeling of a Two-Terminal Active Capacitor

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai; Lu, Minghui

    2017-01-01

    to overcome the above issues. In this paper, the modeling of the active capacitor is investigated and a voltage feed-forward compensation scheme is proposed for overshoot reduction. Therefore, the impedance, equivalent capacitance, ESR, and ESL, of the active capacitor can be specified. A case study based...

  10. Reversible post-breakdown conduction in aluminum oxide-polymer capacitors

    NARCIS (Netherlands)

    Chen, Qian; Gomes, H.L.; Rocha, P.R.F.; Leeuw, de D.M.; Meskers, S.C.J.

    2013-01-01

    Aluminum/Al2O3/polymer/metal capacitors submitted to a low-power constant current stress undergo dielectric breakdown. The post-breakdown conduction is metastable, and over time the capacitors recover their original insulating properties. The decay of the conduction with time follows a power law

  11. Congenital extrahepatic portosystemic shunts

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S. [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Avenue, M5G 1X8, Toronto, Ontario (Canada)

    2003-09-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  12. Congenital extrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S.

    2003-01-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  13. Barium titanate nanocomposite capacitor FY09 year end report.

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Tyler E.; DiAntonio, Christopher Brian; Yang, Pin; Chavez, Tom P.; Winter, Michael R.; Monson, Todd C.; Roesler, Alexander William; Fellows, Benjamin D.

    2009-11-01

    This late start RTBF project started the development of barium titanate (BTO)/glass nanocomposite capacitors for future and emerging energy storage applications. The long term goal of this work is to decrease the size, weight, and cost of ceramic capacitors while increasing their reliability. Ceramic-based nanocomposites have the potential to yield materials with enhanced permittivity, breakdown strength (BDS), and reduced strain, which can increase the energy density of capacitors and increase their shot life. Composites of BTO in glass will limit grain growth during device fabrication (preserving nanoparticle grain size and enhanced properties), resulting in devices with improved density, permittivity, BDS, and shot life. BTO will eliminate the issues associated with Pb toxicity and volatility as well as the variation in energy storage vs. temperature of PZT based devices. During the last six months of FY09 this work focused on developing syntheses for BTO nanoparticles and firing profiles for sintering BTO/glass composite capacitors.

  14. Experimental verification of on-chip CMOS fractional-order capacitor emulators

    KAUST Repository

    Tsirimokou, G.

    2016-06-13

    The experimental results from a fabricated integrated circuit of fractional-order capacitor emulators are reported. The chip contains emulators of capacitors of orders 0.3, 0.4, 0.5, 0.6 and 0.7 with nano-Farad pseudo-capacitances that can be adjusted through a bias current. Two off-chip capacitors are used to set the bandwidth of each emulator independently. The chip was designed in Austria microsystems (AMS) 0.35μ CMOS. © 2016 The Institution of Engineering and Technology.

  15. Experimental verification of on-chip CMOS fractional-order capacitor emulators

    KAUST Repository

    Tsirimokou, G.; Psychalinos, C.; Salama, Khaled N.; Elwakil, A.S.

    2016-01-01

    The experimental results from a fabricated integrated circuit of fractional-order capacitor emulators are reported. The chip contains emulators of capacitors of orders 0.3, 0.4, 0.5, 0.6 and 0.7 with nano-Farad pseudo-capacitances that can be adjusted through a bias current. Two off-chip capacitors are used to set the bandwidth of each emulator independently. The chip was designed in Austria microsystems (AMS) 0.35μ CMOS. © 2016 The Institution of Engineering and Technology.

  16. A Study on the Measurement of Intrapulmonary Shunt in Liver Diseases by the Nucleolide Method

    International Nuclear Information System (INIS)

    Yun, Sung Chul; Ahn, Jae Hee; Choi, Soo Bong

    1987-01-01

    The fact there are increase of intrapulmonary arteriovenous shunt amount in the liver cirrhosis patient has been known since 1950. And the method of shunt amount calculation by radionuclide method using 99m Tc-MAA was introduced in the middle of 1970. We measured intrapulmonary shunt amount by means of perfusion lung scan using 99m Tc-MAA in the various type of liver diseases especially in chronic liver diseases and acute liver disease. The results were as followed. 1) The amount of arteriovenous intrapulmonary shunt in the total case of liver disease was 9.3±3.9%, and that of in the control group was 4.6±2.1%. 2) The amount of arteriovenous intrapulmonary shunt in the chronic liver disease was 10.8±4.4%, and that of in the acute liver disease was 7.2±2.8%. We observed significant differences between normal control group and liver disease group, and between chronic liver disease group and acute liver disease group in the amount of shunt by the nucleolide method.

  17. Capacitor discharge process for welding braided cable

    Science.gov (United States)

    Wilson, Rick D.

    1995-01-01

    A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.

  18. Symmetric Sodium-Ion Capacitor Based on Na0.44MnO2 Nanorods for Low-Cost and High-Performance Energy Storage.

    Science.gov (United States)

    Chen, Zhongxue; Yuan, Tianci; Pu, Xiangjun; Yang, Hanxi; Ai, Xinping; Xia, Yongyao; Cao, Yuliang

    2018-04-11

    Batteries and electrochemical capacitors play very important roles in the portable electronic devices and electric vehicles and have shown promising potential for large-scale energy storage applications. However, batteries or capacitors alone cannot meet the energy and power density requirements because rechargeable batteries have a poor power property, whereas supercapacitors offer limited capacity. Here, a novel symmetric sodium-ion capacitor (NIC) is developed based on low-cost Na 0.44 MnO 2 nanorods. The Na 0.44 MnO 2 with unique nanoarchitectures and iso-oriented feature offers shortened diffusion path lengths for both electronic and Na + transport and reduces the stress associated with Na + insertion and extraction. Benefiting from these merits, the symmetric device achieves a high power density of 2432.7 W kg -1 , an improved energy density of 27.9 Wh kg -1 , and a capacitance retention of 85.2% over 5000 cycles. Particularly, the symmetric NIC based on Na 0.44 MnO 2 permits repeatedly reverse-polarity characteristics, thus simplifying energy management system and greatly enhancing the safety under abuse condition. This cost-effective, high-safety, and high-performance symmetric NIC can balance the energy and power density between batteries and capacitors and serve as an electric power source for future low-maintenance large-scale energy storage systems.

  19. Continuous monitoring of intracranial pressure after endoscopic third ventriculostomy in the management of CSF shunt failure.

    Science.gov (United States)

    Elgamal, E A

    2010-04-01

    The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.

  20. Medication overuse as a cause of chronic headache in shunted hydrocephalus patients

    DEFF Research Database (Denmark)

    Willer, Lasse; Jensen, R H; Juhler, M

    2010-01-01

    To highlight the group of hydrocephalus patients known to have a long history of shunt revisions and refractory chronic headache. When a shunt in perfect working order has no effect on headache, other causes of headache should be investigated. In this paper, patients with medication overuse...

  1. Graphene electric double layer capacitor with ultra-high-power performance

    International Nuclear Information System (INIS)

    Miller, John R.; Outlaw, R.A.; Holloway, B.C.

    2011-01-01

    We have demonstrated, for the first time, efficient 120 Hz filtering by an electric double layer capacitor (EDLC). The key to this ultra-high-power performance is electrodes made from vertically oriented graphene nanosheets grown directly on metal current collectors. This design minimized both electronic and ionic resistance and produced capacitors having RC time-constants of less than 200 μs. Significantly, graphene nanosheets have a preponderance of exposed edge planes that greatly increase stored charge over designs relying on basal plane surfaces. Collectively these factors make vertically oriented graphene nanosheet electrodes ideally suited for producing high-frequency EDLCs. Capacitors constructed with these electrodes are predicted to be significantly smaller than aluminum electrolyte capacitors that they could functionally replace plus be manufactured using standard semiconductor process equipment, creating interesting commercial opportunities.

  2. Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

    Science.gov (United States)

    Wu, Shu-Yau; Turner, Travis L.; Rizzi, Stephen A.

    2000-01-01

    At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL

  3. Treatment of Hydrocephalus Associated with Neurosarcoidosis by Multiple Shunt Placement

    OpenAIRE

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-01-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showe...

  4. Die transkranielle Doppler-Sonographie zur Identifikation von Rechts-Links-Shunts

    OpenAIRE

    Jekentaite, R. (Ruta)

    2003-01-01

    Paradoxe Embolien über einen Rechts-Links-Shunt (RLS) stellen eine Ursache von Hirninfarkten dar. Diese Shunts werden mittels TEE oder TCD diagnostiziert. Ziele dieser Studie waren die Bestimmung des optimalen Timings des Valsalva-Manövers (VM) sowie Vergleich der zwei Kontrastmittel Echovist®-300 und Echovist®-200. 64 Patienten wurden mittels beider Methoden untersucht. Nach der KM-Injektion wurden die Mikroemboliesignale (MES) in der ACM bilateral dopplersonographisch registriert. Die Unt...

  5. Graphene spin capacitor for magnetic field sensing

    OpenAIRE

    Semenov, Y. G.; Zavada, J. M.; Kim, K. W.

    2010-01-01

    An analysis of a novel magnetic field sensor based on a graphene spin capacitor is presented. The proposed device consists of graphene nanoribbons on top of an insulator material connected to a ferromagnetic source/drain. The time evolution of spin polarized electrons injected into the capacitor can be used for an accurate determination at room temperature of external magnetic fields. Assuming a spin relaxation time of 100 ns, magnetic fields on the order of $\\sim 10$ mOe may be detected at r...

  6. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    Science.gov (United States)

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  7. Control of an innovative super-capacitor-powered shape-memory-alloy actuated accumulator for blowout preventer

    Science.gov (United States)

    Chen, Jian; Li, Peng; Song, Gangbing; Ren, Zhang

    2017-01-01

    The design of a super-capacitor-powered shape-memory-alloy (SMA) actuated accumulator for blowout preventer (BOP) presented in this paper featured several advantages over conventional hydraulic accumulators including instant large current drive, quick system response and elimination of need for the pressure conduits. However, the mechanical design introduced two challenges, the nonlinear nature of SMA actuators and the varying voltage provided by a super capacitor, for control system design. A cerebellar model articulation controller (CMAC) feedforward plus PID controller was developed with the aim of compensation for these adverse effects. Experiments were conducted on a scaled down model and experimental results show that precision control can be achieved with the proposed configurations and algorithms.

  8. Comb-Line Filter with Coupling Capacitor in Ground Plane

    Directory of Open Access Journals (Sweden)

    Toshiaki Kitamura

    2011-01-01

    Full Text Available A comb-line filter with a coupling capacitor in the ground plane is proposed. The filter consists of two quarter-wavelength microstrip resonators. A coupling capacitor is inserted into the ground plane in order to build strong coupling locally along the resonators. The filtering characteristics are investigated through numerical simulations as well as experiments. Filtering characteristics that have attenuation poles at both sides of the passband are obtained. The input susceptances of even and odd modes and coupling coefficients are discussed. The filters using stepped impedance resonators (SIRs are also discussed, and the effects of the coupling capacitor for an SIR structure are shown.

  9. Device for detecting imminent failure of high-dielectric stress capacitors. [Patent application

    Science.gov (United States)

    McDuff, G.G.

    1980-11-05

    A device is described for detecting imminent failure of a high-dielectric stress capacitor utilizing circuitry for detecting pulse width variations and pulse magnitude variations. Inexpensive microprocessor circuitry is utilized to make numerical calculations of digital data supplied by detection circuitry for comparison of pulse width data and magnitude data to determine if preselected ranges have been exceeded, thereby indicating imminent failure of a capacitor. Detection circuitry may be incorporated in transmission lines, pulse power circuitry, including laser pulse circuitry or any circuitry where capacitors or capacitor banks are utilized.

  10. Thyristor-controlled reactor improves series capacitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Renz, K.W.; Thumm, G.; Weiss, S. [Siemens AG, Erlangen (Germany)

    1995-12-31

    Environmental considerations make it more and more difficult to plan and erect new transmission lines. FACTS (Flexible AC Transmission Systems) technology can provide devices to improve the utility of AC transmission lines. The innovative combination of conventional fixed series capacitors and thyristor controlled reactors as a new FACTS device was introduced into a transmission system in 1992. This Advanced Series Compensation (ASC) system provides many advantages not available with conventional fixed series capacitor installations such as flexible direct and continuous control of the compensation level, direct and smooth power flow control and improved capacitor bank protection. This new technology offers enhanced system flexibility by control of transmission line overload conditions, reduction in fault currents, sub-synchronous resonance (SSR) mitigation and network power oscillation damping. The world-first three-phase installation at Kayenta Substation, USA, demonstrates that modern FACTS devices using SVC thyristor valve technology can be designed and operated successfully. 6 refs, 7 figs

  11. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  12. Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    Rössle M

    2018-01-01

    Full Text Available The availability of polytetrafluoroethylene (PTFE covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS. Side effects of portosystemic shunting such as hepatic encephalopathy (HE and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm. During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%, four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10% developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

  13. Effects of isradipine and other calcium antagonists on arteriovenous-shunt flow in anesthetized rabbits and cats

    International Nuclear Information System (INIS)

    Hof, R.P.

    1989-01-01

    The effects of vasodilators on arteriovenous (AV)-shunt flow was investigated in anesthetized cats and rabbits, using the tracer microsphere method. In cats, the calcium antagonist isradipine reduced AV-shunt flow; verapamil showed a similar tendency and nicardipine was without effect. Dihydralazine strongly increased, but nitroglycerin and dipyridamole decreased AV-shunt flow. In rabbits, the effects of isradipine and verapamil were similar to those seen in cats. Sodium nitroprusside had no effect, whereas prazosin, minoxidil, and the potassium-channel activator cromakalim increased AV-shunt flow. The contrasting effects of drugs sharing the same mechanism of action suggest that target-tissue selectivity is more important than the mechanism of action. An increase of AV-shunt flow is unlikely to be beneficial but could be associated with a number of undesirable side effects. It might negatively affect migraine sufferers and, if AV-shunt dilatation shows no tolerance development, it represents an unnecessary hemodynamic burden for the heart

  14. Nanostructured Anodic Multilayer Dielectric Stacked Metal-Insulator-Metal Capacitors.

    Science.gov (United States)

    Karthik, R; Kannadassan, D; Baghini, Maryam Shojaei; Mallick, P S

    2015-12-01

    This paper presents the fabrication of Al2O3/TiO2/Al2O3 metal-insulator-metal (MIM) capacitor using anodization technique. High capacitance density of > 3.5 fF/μm2, low quadratic voltage coefficient of capacitance of dielectric stack required for high performance MIM capacitor.

  15. A high-performance trench capacitor integrated in a passive integration technology

    International Nuclear Information System (INIS)

    Geiselbrechtinger, Angelika; Büyüktas, Kevni; Allers, Karl-Heinz; Hartung, Wolfgang

    2009-01-01

    The requirements for the electrical characteristics of passive on-chip devices become more and more important. The electrical performance of RF circuits is predominantly restricted by the passives. New technologies and new device concepts are necessary to meet the demands. In this work, a trench capacitor developed for RF applications is presented for the first time. This so-called SilCap (silicon capacitor) device features very high capacitance density, extreme low-voltage dependence, excellent temperature stability, good RF performance and a high breakthrough voltage. First, the device function and the technological concept are introduced. The concept is realized without implementing cost-intensive high-k materials. This trench capacitor is integrated in the front end of line of a passive integration technology. The achieved specific capacitance density is compared to a standard planar capacitor. Performance of the SilCap in terms of quality factor and breakthrough voltage is shown. Finally, reliability data of this trench capacitor are presented with special focus on extrinsic and dielectric lifetime

  16. An in vitro lung model to assess true shunt fraction by multiple inert gas elimination.

    Directory of Open Access Journals (Sweden)

    Balamurugan Varadarajan

    Full Text Available The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I to construct a novel in vitro lung model (IVLM for the simulation of predefined V/Q distributions with five gas exchange compartments and (II to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V and perfused with human red cell suspension or saline (Q. Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V was kept constant and reference shunt fractions (IVLM-S were established by bypassing one or more oxygenators with perfusate flow (Q. The derived shunt fractions (MM-S were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.

  17. Soft capacitor fibers using conductive polymers for electronic textiles

    Science.gov (United States)

    Gu, Jian Feng; Gorgutsa, Stephan; Skorobogatiy, Maksim

    2010-11-01

    A novel, highly flexible, conductive polymer-based fiber with high electric capacitance is reported. In its cross section the fiber features a periodic sequence of hundreds of conductive and isolating plastic layers positioned around metallic electrodes. The fiber is fabricated using the fiber drawing method, where a multi-material macroscopic preform is drawn into a sub-millimeter capacitor fiber in a single fabrication step. Several kilometers of fibers can be obtained from a single preform with fiber diameters ranging between 500 and 1000 µm. A typical measured capacitance of our fibers is 60-100 nF m-1 and it is independent of the fiber diameter. Analysis of the fiber frequency response shows that in its simplest interrogation mode the capacitor fiber has a transverse resistance of 5 kΩ m L-1, which is inversely proportional to the fiber length L and is independent of the fiber diameter. Softness of the fiber materials, the absence of liquid electrolyte in the fiber structure, ease of scalability to large production volumes and high capacitance of our fibers make them interesting for various smart textile applications ranging from distributed sensing to energy storage.

  18. Soft capacitor fibers using conductive polymers for electronic textiles

    International Nuclear Information System (INIS)

    Gu, Jian Feng; Gorgutsa, Stephan; Skorobogatiy, Maksim

    2010-01-01

    A novel, highly flexible, conductive polymer-based fiber with high electric capacitance is reported. In its cross section the fiber features a periodic sequence of hundreds of conductive and isolating plastic layers positioned around metallic electrodes. The fiber is fabricated using the fiber drawing method, where a multi-material macroscopic preform is drawn into a sub-millimeter capacitor fiber in a single fabrication step. Several kilometers of fibers can be obtained from a single preform with fiber diameters ranging between 500 and 1000 µm. A typical measured capacitance of our fibers is 60–100 nF m −1 and it is independent of the fiber diameter. Analysis of the fiber frequency response shows that in its simplest interrogation mode the capacitor fiber has a transverse resistance of 5 kΩ m L −1 , which is inversely proportional to the fiber length L and is independent of the fiber diameter. Softness of the fiber materials, the absence of liquid electrolyte in the fiber structure, ease of scalability to large production volumes and high capacitance of our fibers make them interesting for various smart textile applications ranging from distributed sensing to energy storage

  19. Capacitor-based detection of nuclear magnetization: nuclear quadrupole resonance of surfaces.

    Science.gov (United States)

    Gregorovič, Alan; Apih, Tomaž; Kvasić, Ivan; Lužnik, Janko; Pirnat, Janez; Trontelj, Zvonko; Strle, Drago; Muševič, Igor

    2011-03-01

    We demonstrate excitation and detection of nuclear magnetization in a nuclear quadrupole resonance (NQR) experiment with a parallel plate capacitor, where the sample is located between the two capacitor plates and not in a coil as usually. While the sensitivity of this capacitor-based detection is found lower compared to an optimal coil-based detection of the same amount of sample, it becomes comparable in the case of very thin samples and even advantageous in the proximity of conducting bodies. This capacitor-based setup may find its application in acquisition of NQR signals from the surface layers on conducting bodies or in a portable tightly integrated nuclear magnetic resonance sensor. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Prognostics Health Management and Physics based failure Models for Electrolytic Capacitors

    Data.gov (United States)

    National Aeronautics and Space Administration — This paper proposes first principles based modeling and prognostics approach for electrolytic capacitors. Electrolytic capacitors and MOSFETs are the two major...