WorldWideScience

Sample records for large residual urine

  1. Residual urine output and postoperative mortality in maintenance hemodialysis patients.

    Science.gov (United States)

    Lin, Yu-Feng; Wu, Vin-Cent; Ko, Wen-Je; Chen, Yih-Sharng; Chen, Yung-Ming; Li, Wen-Yi; Chou, Nai-Kuan; Chao, Anne; Huang, Tao-Min; Chang, Fan-Chi; Chen, Shih-I; Shiao, Chih-Chung; Wang, Wei-Jie; Tsai, Hung-Bin; Tsai, Pi-Ru; Hu, Fu-Chang; Wu, Kwan-Dun

    2009-09-01

    The relationship between residual urine output and postoperative survival in maintenance hemodialysis patients is unknown. To explore the relationship between amount of urine before surgery and postoperative mortality and differences between postoperative nonanuria and anuria in maintenance hemodialysis patients. A total of 109 maintenance hemodialysis patients underwent major operations. Anuria was defined as urine output <30 mL in the 8 hours before the first session of postoperative dialysis. Propensity scores for postoperative anuria were developed. Postoperative residual urine output was 159.2 mL/8 h (SD, 115.1) in 33 patients; 76 patients were anuric. Preoperative residual urine output and adequate perioperative blood transfusion were positively related to postoperative urine output. Propensity-adjusted 30-day mortality was associated with postoperative anuria (odds ratio [OR], 4.56; 95% confidence interval [CI], 1.16-17.96; P = .03), prior stroke (OR, 4.46; 95% CI, 1.43-13.89; P = .01) and higher disease severity (OR, 1.10; 95% CI, 1.00-1.21; P = .049) at the first postoperative dialysis. OR of 30-day mortality was 5.38 for nonanuria to anuria vs nonanuria to nonanuria (P = .03) and 5.13 for preoperative anuria vs nonanuria to nonanuria (P = .01). By Kaplan-Meier analysis, 30-day mortality differed significantly among patients for nonanuria to nonanuria, anuria, and nonanuria to anuria (log rank, P = .045). Patients with preoperative nonanuria and postoperative anuria had higher mortality than did patients with no anuria before and after surgery and patients with anuria before surgery. Postoperative residual urine output is an important surrogate marker for disease severity.

  2. Radiographic determination of urinary bladder volume and residual urine volume

    International Nuclear Information System (INIS)

    Klumair, J.

    1977-01-01

    In the course of a long study the author has tested most of the methods for determination of urinary bladder volume. A radiographic method which can state bladder volume exactly in cc's is attainable only with great time and effort. In the author's experience, however, it is possible, by means of a pattern in connection with a IVP, to estimate residual urine volume from a post-void picture of the bladder with sufficient accuracy for practical purposes. An account is given of the production of this pattern and of two relatively simple calculations for residual volume based on AP and lateral views of circular- and ellipsoid-shaped bladders. Also discussed is the radiation exposure which varies with the radiographic methods used. In male patients, the radiation exposure appears to be negligible, especially when the testicles are protected by a radiation shield. In female patients - which make up only a small fraction of all patients -, radiation exposure is higher but must be accepted. (orig./MG) [de

  3. Residual cannabis levels in blood, urine and oral fluid following heavy cannabis use.

    Science.gov (United States)

    Odell, Morris S; Frei, Matthew Y; Gerostamoulos, Dimitri; Chu, Mark; Lubman, Dan I

    2015-04-01

    An understanding of tetrahydrocannabinol (THC) kinetics and residual levels after cannabis use is essential in interpreting toxicology tests in body fluids from live subjects, particularly when used in forensic settings for drug abuse, traffic and interpersonal violence cases. However the current literature is largely based on laboratory studies using controlled cannabis dosages in experienced users, with limited research investigating the kinetics of residual THC concentrations in regular high dose cannabis users. Twenty-one dependent cannabis users were recruited at admission to two residential detoxification units in Melbourne, Australia. After being provided with information about, and consenting to, the study, subjects volunteered to provide once-daily blood, urine and oral fluid (saliva) samples for seven consecutive days following admission, involving cessation and abstinence from all cannabis use. Blood and oral fluid specimens were analysed for THC and urine specimens for the metabolite THC-COOH. In some subjects THC was detectable in blood for at least 7 days and oral fluid specimens were positive for THC up to 78 h after admission to the unit. Urinary THC-COOH concentrations exceeded 1000 ng/mL for some subjects 129 h after last use. The presented blood THC levels are higher and persist longer in some individuals than previously described, our understanding and interpretation of THC levels in long term heavy cannabis users may need to be reconsidered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Post-void residual urine under 150 ml does not exclude voiding dysfunction in women

    DEFF Research Database (Denmark)

    Khayyami, Yasmine; Klarskov, Niels; Lose, Gunnar

    2016-01-01

    INTRODUCTION AND HYPOTHESIS: It has been claimed that post-void residual urine (PVR) below 150 ml rules out voiding dysfunction in women with stress urinary incontinence (SUI) and provides license to perform sling surgery. The cut-off of 150 ml seems arbitrary, not evidence-based, and so we sough...

  5. Elemental quantification of large gunshot residues

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, A. [Ion Implantation Laboratory, Institute of Physics, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, P.O. Box 15051, CEP 91501-970 Porto Alegre, RS (Brazil); Graduate Program on Materials Science, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, CEP 91540-000 Porto Alegre, RS (Brazil); Silva, L.M. [Ion Implantation Laboratory, Institute of Physics, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, P.O. Box 15051, CEP 91501-970 Porto Alegre, RS (Brazil); Graduate Program on Materials Science, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, CEP 91540-000 Porto Alegre, RS (Brazil); Forensic Institute of Porto Alegre, Av. Princesa Isabel 1056, CEP 90230-010 Porto Alegre, RS (Brazil); Souza, C.T. de; Stori, E.M. [Ion Implantation Laboratory, Institute of Physics, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, P.O. Box 15051, CEP 91501-970 Porto Alegre, RS (Brazil); Boufleur, L.A. [Ion Implantation Laboratory, Institute of Physics, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, P.O. Box 15051, CEP 91501-970 Porto Alegre, RS (Brazil); Graduate Program on Materials Science, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, CEP 91540-000 Porto Alegre, RS (Brazil); Amaral, L. [Ion Implantation Laboratory, Institute of Physics, Federal University of Rio Grande do Sul, Av. Bento Gonçalves 9500, P.O. Box 15051, CEP 91501-970 Porto Alegre, RS (Brazil); and others

    2015-04-01

    In the present work we embarked on the evaluation of the Sb/Pb, Ba/Pb and Sb/Ba elemental ratios found in relatively large particles (of the order of 50–150 μm across) ejected in the forward direction when a gun is fired. These particles are commonly referred to as gunshot residues (GSR). The aim of this work is to compare the elemental ratios of the GSR with those found in the primer of pristine cartridges in order to check for possible correlations. To that end, the elemental concentration of gunshot residues and the respective ammunition were investigated through PIXE (Particle-Induced X-ray Emission) and micro-PIXE techniques. The ammunition consisted of a .38 SPL caliber (ogival lead type) charged in a Taurus revolver. Pristine cartridges were taken apart for the PIXE measurements. The shooting sessions were carried out in a restricted area at the Forensic Institute at Porto Alegre. Residues ejected at forward directions were collected on a microporous tape. The PIXE experiments were carried out employing 2.0 MeV proton beams with a beam spot size of 1 mm{sup 2}. For the micro-PIXE experiments, the samples were irradiated with 2.2 MeV proton beams of 2 × 2 μm{sup 2}. The results found for the ratios of Sb/Pb, Ba/Pb and Sb/Ba do not correlate with those stemming from the analysis of the primer.

  6. Elemental quantification of large gunshot residues

    International Nuclear Information System (INIS)

    Duarte, A.; Silva, L.M.; Souza, C.T. de; Stori, E.M.; Boufleur, L.A.; Amaral, L.

    2015-01-01

    In the present work we embarked on the evaluation of the Sb/Pb, Ba/Pb and Sb/Ba elemental ratios found in relatively large particles (of the order of 50–150 μm across) ejected in the forward direction when a gun is fired. These particles are commonly referred to as gunshot residues (GSR). The aim of this work is to compare the elemental ratios of the GSR with those found in the primer of pristine cartridges in order to check for possible correlations. To that end, the elemental concentration of gunshot residues and the respective ammunition were investigated through PIXE (Particle-Induced X-ray Emission) and micro-PIXE techniques. The ammunition consisted of a .38 SPL caliber (ogival lead type) charged in a Taurus revolver. Pristine cartridges were taken apart for the PIXE measurements. The shooting sessions were carried out in a restricted area at the Forensic Institute at Porto Alegre. Residues ejected at forward directions were collected on a microporous tape. The PIXE experiments were carried out employing 2.0 MeV proton beams with a beam spot size of 1 mm 2 . For the micro-PIXE experiments, the samples were irradiated with 2.2 MeV proton beams of 2 × 2 μm 2 . The results found for the ratios of Sb/Pb, Ba/Pb and Sb/Ba do not correlate with those stemming from the analysis of the primer

  7. Post-voiding residual urine and capacity increase in orthotopic urinary diversion: Standard vs modified technique

    Directory of Open Access Journals (Sweden)

    Bančević Vladimir

    2010-01-01

    Full Text Available Background/Aim. Ever since the time when the first orthotopic urinary diversion (pouch was performed there has been a constant improvement and modification of surgical techniques. The aim has been to create a urinary reservoir similar to normal bladder, to decrease incidence of postoperative complications and provide an improved life quality. The aim of this study was to compare postvoiding residual urine (PVR and capacity of the pouch constructed by standard or modified technique. Methods. In this prospective and partially retrospective clinical study we included 79 patients. In the group of 41 patients (group ST pouch was constructed using 50-70 cm of the ileum (standard technique. In the group of 38 patients (group MT pouch was constructed using 25-35 cm of the ileum (modified technique. Postoperatively, PVR and pouch capacity were measured using ultrasound in a 3-, 6- and 12-month period. Results. Postoperatively, an increase in PVR and pouch capacity was noticed in both groups. Twelve months postoperatively, PVR was significantly smaller in the group MT than in the group ST [23 (0-90 mL vs 109 (0-570 mL, p < 0,001]. In the same period the pouch capacity was significantly smaller in the MT group than in the ST group [460 (290-710 mL vs 892 (480-2 050 mL, p < 0.001]. Conclusion. Postoperatively, an increase in PVR and pouch capacity was noticed during a 12-month period. A year following the operation the pouch created from a shorter ileal segment reached capacity of the 'normal' bladder with small PVR. The pouch created by standard technique developed an unnecessary large PVR and capacity.

  8. Detection of residual rifampicin in urine via fluorescence quenching of gold nanoclusters on paper.

    Science.gov (United States)

    Chatterjee, Krishnendu; Kuo, Chiung Wen; Chen, Ann; Chen, Peilin

    2015-06-26

    Rifampicin or rifampin (R) is a common drug used to treat inactive meningitis, cholestatic pruritus and tuberculosis (TB), and it is generally prescribed for long-term administration under regulated dosages. Constant monitoring of rifampicin is important for controlling the side effects and preventing overdose caused by chronic medication. In this study, we present an easy to use, effective and less costly method for detecting residual rifampicin in urine samples using protein (bovine serum albumin, BSA)-stabilized gold nanoclusters (BSA-Au NCs) adsorbed on a paper substrate in which the concentration of rifampicin in urine can be detected via fluorescence quenching. The intensity of the colorimetric assay performed on the paper-based platforms can be easily captured using a digital camera and subsequently analyzed. The decreased fluorescence intensity of BSA-Au NCs in the presence of rifampicin allows for the sensitive detection of rifampicin in a range from 0.5 to 823 µg/mL. The detection limit for rifampicin was measured as 70 ng/mL. The BSA-Au NCs were immobilized on a wax-printed paper-based platform and used to conduct real-time monitoring of rifampicin in urine. We have developed a robust, cost-effective, and portable point-of-care medical diagnostic platform for the detection of rifampicin in urine based on the ability of rifampicin to quench the fluorescence of immobilized BSA-Au NCs on wax-printed papers. The paper-based assay can be further used for the detection of other specific analytes via surface modification of the BSA in BSA-Au NCs and offers a useful tool for monitoring other diseases.

  9. Urinary retention and post-void residual urine in men: separating truth from tradition.

    Science.gov (United States)

    Kaplan, Steven A; Wein, Alan J; Staskin, David R; Roehrborn, Claus G; Steers, William D

    2008-07-01

    The definitions of acute and chronic urinary retention remain empirical and subject to wide interpretation. Standardized criteria have not been established and many questions remain unanswered. Moreover, the definition of significant post-void residual urine is unclear. We reviewed several aspects of urinary retention that require clarification with the objective of stimulating discussion among urologists to establish an accurate and coherent definition of urinary retention and significant post-void residual urine, and clarify risk factors. A MEDLINE search for articles written in English and published before April 2007 was done using a list of terms related to urinary retention. Articles not directly relevant to urinary retention or post-void residual urine were excluded. The term urinary retention lacks precise clinical or urodynamic meaning. Use of this term to describe a symptom, a sign, and a condition further complicates the issue. Many factors can contribute to the development of retention, including bladder outlet obstruction, detrusor underactivity, and neurogenic bladder conditions. Community based studies and clinical trials in patients with benign prostatic enlargement and/or lower urinary tract symptoms yield different estimates of the incidence of retention and only provide information on the epidemiology of acute urinary retention. However, age, previous retention episodes, lower urinary tract symptoms, chronic inflammation, serum prostate specific antigen level, prostate size, and urodynamic variables appear to be predictors of acute urinary retention. Alpha-receptor antagonists and 5alpha-reductase inhibitors may be useful in preventing urinary retention episodes and progressive benign prostatic enlargement. Clinical trials on the short-term use of antimuscarinics have not provided evidence that these agents increase the risk of retention; data on longer term administration are needed. Clinicians are adopting less invasive approaches (eg

  10. Plasma Levels of Middle Molecules to Estimate Residual Kidney Function in Haemodialysis without Urine Collection.

    Directory of Open Access Journals (Sweden)

    Enric Vilar

    Full Text Available Residual Kidney Function (RKF is associated with survival benefits in haemodialysis (HD but is difficult to measure without urine collection. Middle molecules such as Cystatin C and β2-microglobulin accumulate in renal disease and plasma levels have been used to estimate kidney function early in this condition. We investigated their use to estimate RKF in patients on HD.Cystatin C, β2-microglobulin, urea and creatinine levels were studied in patients on incremental high-flux HD or hemodiafiltration(HDF. Over sequential HD sessions, blood was sampled pre- and post-session 1 and pre-session 2, for estimation of these parameters. Urine was collected during the whole interdialytic interval, for estimation of residual GFR (GFRResidual = mean of urea and creatinine clearance. The relationships of plasma Cystatin C and β2-microglobulin levels to GFRResidual and urea clearance were determined.Of the 341 patients studied, 64% had urine output>100 ml/day, 32.6% were on high-flux HD and 67.4% on HDF. Parameters most closely correlated with GFRResidual were 1/β2-micoglobulin (r2 0.67 and 1/Cystatin C (r2 0.50. Both these relationships were weaker at low GFRResidual. The best regression model for GFRResidual, explaining 67% of the variation, was: GFRResidual = 160.3 · (1/β2m - 4.2. Where β2m is the pre-dialysis β2 microglobulin concentration (mg/L. This model was validated in a separate cohort of 50 patients using Bland-Altman analysis. Areas under the curve in Receiver Operating Characteristic analysis aimed at identifying subjects with urea clearance≥2 ml/min/1.73 m2 was 0.91 for β2-microglobulin and 0.86 for Cystatin C. A plasma β2-microglobulin cut-off of ≤19.2 mg/L allowed identification of patients with urea clearance ≥2 ml/min/1.73 m2 with 90% specificity and 65% sensitivity.Plasma pre-dialysis β2-microglobulin levels can provide estimates of RKF which may have clinical utility and appear superior to cystatin C. Use of cut-off levels

  11. Unnoticed Post-Void Residual Urine Volume in People with Moderate to Severe Intellectual Disabilities: Prevalence and Risk Factors

    Science.gov (United States)

    de Waal, K. H.; Tinselboer, B. M.; Evenhuis, H. M.; Penning, C.

    2009-01-01

    Background: Increased post-void residual urine volume (PVR) is often seen in geriatric populations. People with intellectual disabilities (ID) have risk factors in common with these populations. Aims: To investigate in adults with ID: (1) Feasibility of portable ultrasound bladder scanning; (2) Prevalence of PVR; and (3) Relations with proposed…

  12. Radionuclide measurement of urinary flow rates and residual urine in the evaluation of bladder outflow obstruction

    International Nuclear Information System (INIS)

    Groshar, D.; Embon, O.M.; Sazbon, A.; Koritny, E.; Frankel, A.

    1986-01-01

    A radionuclide method was developed to evaluate bladder outflow obstruction. Forty-seven patients with prostatic hypertrophy and 29 controls were studied. Urinary mean (MRF) and peak (PFR) flow rates were determined from the time-activity curves of bladder emptying. Residual urine (RU) was calculated by the volume voided and the bladder ejection fraction. A corrected PFR was calculated [CPFR = PFR/(vol. voided + RU)/sup 1/2/]. There was significant difference between patients and controls (MFR = 4 +- 2 vs. 9 +- 4 ml/sec, P <.001; PFR = 10 +- 6 vs. 20 +- 7, P <.001; CPFR = 0.57 +- 0.21 vs. 1.22 +- 0.32, P <.0001). RU was 13 +- 13 ml in controls and 155 +- 285 ml in patients (P <.01). CPFR was less than 0.89 in 94% of patients and 10% of controls, PFR was less than 14 ml/sec in 79% of patients and 17% of controls, and MFR was less than 7 ml/sec in 91% of patients and 21% of controls. The method enables good separation between patients and controls in a single examination that measures both flow and volume

  13. Elevated postvoid residual urine volume predicting recurrence of urinary tract infections in toilet-trained children.

    Science.gov (United States)

    Chang, Shang-Jen; Tsai, Li-Ping; Hsu, Chun-Kai; Yang, Stephen S

    2015-07-01

    The aim of this study was to examine whether toilet-trained children with a history of febrile urinary tract infection (fUTI) and elevated postvoid residual (PVR) urine volume according to a recently published PVR nomogram were at greater risk of UTI recurrence. One month after recovery from febrile UTI, constipation was diagnosed according to the Rome III criteria, and lower urinary tract (LUT) function was evaluated with two sets of uroflowmetry and PVR by ultrasonography. For children aged ≦ 6 and ≧ 7 years, elevated PVR is defined as >20 and >10 ml, respectively. Cox proportion hazards regression was used to evaluate the risk factors for recurrence of UTI. Between 2005 and 2011, 60 children aged 6.5 ± 2.5 years (boy:girl ratio 27:33) were enrolled for analysis. Univariate analysis showed that recurrent febrile UTI was more commonly observed in children with elevated PVR [repetitive elevated PVR: hazard ratio (HR) 5.75, 95% confidence interval (CI) 1.41-23.4; one elevated PVR: HR 4.53, 95% CI 1.01-20.2] and high-grade vesicoureteral reflux (VUR; HR 4.53, 95% CI 1.46-14.07). Multivariate analysis showed that younger age (HR 1.37, 95% CI 1.03-1.82, p UTI--but not gender, presence of high-grade VUR and constipation. Elevated PVR defined by the new PVR nomogram predicted recurrent UTI in children with history of febrile UTI. Care should be taken to manage children with elevated PVR.

  14. A Rare Large Residual Cyst of the Mandible

    Directory of Open Access Journals (Sweden)

    Setareh Shojaei

    2016-02-01

    Full Text Available Introduction: A residual cyst is a periapical cyst persisted after its associated tooth had been extracted. Case Presentation: A 59-year-old Iranian man complaining of a dull pain in his left side of the mandible after falling down one month ago was referred to the department of oral and maxillofacial pathology, Hamadan University of Medical Sciences, Iran. Panoramic film revealed a radiolucent lesion and fracture of the mandible at the right side. An excisional biopsy was obtained. Based on the histopathologic findings, residual cyst was diagnosed. Conclusions: We reported a rare case of large residual cyst. Dental practitioners should consider this lesion in the differential diagnosis of radiolucent lesions of the jaw bone.

  15. Persons with Mild or Moderate Alzheimer's Disease Learn to Use Urine Alarms and Prompts to Avoid Large Urinary Accidents

    Science.gov (United States)

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco

    2011-01-01

    This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…

  16. Highly conserved small subunit residues influence rubisco large subunit catalysis.

    Science.gov (United States)

    Genkov, Todor; Spreitzer, Robert J

    2009-10-30

    The chloroplast enzyme ribulose 1,5-bisphosphate carboxylase/oxygenase (Rubisco) catalyzes the rate-limiting step of photosynthetic CO(2) fixation. With a deeper understanding of its structure-function relationships and competitive inhibition by O(2), it may be possible to engineer an increase in agricultural productivity and renewable energy. The chloroplast-encoded large subunits form the active site, but the nuclear-encoded small subunits can also influence catalytic efficiency and CO(2)/O(2) specificity. To further define the role of the small subunit in Rubisco function, the 10 most conserved residues in all small subunits were substituted with alanine by transformation of a Chlamydomonas reinhardtii mutant that lacks the small subunit gene family. All the mutant strains were able to grow photosynthetically, indicating that none of the residues is essential for function. Three of the substitutions have little or no effect (S16A, P19A, and E92A), one primarily affects holoenzyme stability (L18A), and the remainder affect catalysis with or without some level of associated structural instability (Y32A, E43A, W73A, L78A, P79A, and F81A). Y32A and E43A cause decreases in CO(2)/O(2) specificity. Based on the x-ray crystal structure of Chlamydomonas Rubisco, all but one (Glu-92) of the conserved residues are in contact with large subunits and cluster near the amino- or carboxyl-terminal ends of large subunit alpha-helix 8, which is a structural element of the alpha/beta-barrel active site. Small subunit residues Glu-43 and Trp-73 identify a possible structural connection between active site alpha-helix 8 and the highly variable small subunit loop between beta-strands A and B, which can also influence Rubisco CO(2)/O(2) specificity.

  17. Exposure of the Public from Large Deposits of Mineral Residues

    International Nuclear Information System (INIS)

    2011-06-01

    All minerals and raw materials contain radionuclides of natural origin. In most situations, the exposure of humans to such radionuclides is considered to be part of the normal natural radiation background and is not generally of concern. In some cases, however, the radionuclide concentrations are elevated above normal levels or become elevated as a result of mineral processing activities, and measures for protecting against exposure to the material involved may need to be considered. The mineral or raw material is then treated as radioactive material for the purposes of radiation protection and falls within the definition of naturally occurring radioactive material (NORM). The IAEA has developed criteria for determining which materials need to be considered for regulatory control. For materials containing only radionuclides of natural origin, the criteria are an activity concentration of 1 Bq/g for 238 U, 235 U, 232 Th and their decay progeny and an activity concentration of 10 Bq/g for 40 K. These values were determined on the basis of the activity concentrations of these radionuclides in normal rocks and soil, and represent the (rounded) upper bounds of the ranges of such concentrations as determined by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). The values are intended to apply to all solid materials except foodstuffs, material in transport and radioactive residues in the environment (for which separate criteria apply) and 40 K in the body (which is excluded entirely from regulatory requirements). While the radiation dose was not a consideration in the determination of the above-mentioned regulatory criteria, the IAEA has noted that doses received by individuals as a consequence of the use of these criteria are unlikely to exceed about 1 mSv in a year, excluding the emanation of radon. However, in the case of bulk volumes of material contaminating water pathways, such as large deposits of NORM residues from mining and

  18. Should measurement of maximum urinary flow rate and residual urine volume be a part of a "minimal care" assessment programme in female incontinence?

    DEFF Research Database (Denmark)

    Sander, Pia; Mouritsen, L; Andersen, J Thorup

    2002-01-01

    OBJECTIVE: The aim of this study was to evaluate the value of routine measurements of urinary flow rate and residual urine volume as a part of a "minimal care" assessment programme for women with urinary incontinence in detecting clinical significant bladder emptying problems. MATERIAL AND METHODS....... Twenty-six per cent had a maximum flow rate less than 15 ml/s, but only 4% at a voided volume > or =200 ml. Residual urine more than 149 ml was found in 6%. Two women had chronic retention with overflow incontinence. Both had typical symptoms with continuous leakage, stranguria and chronic cystitis...

  19. Vascular calcification and cardiac function according to residual renal function in patients on hemodialysis with urination.

    Directory of Open Access Journals (Sweden)

    Dong Ho Shin

    Full Text Available Vascular calcification is common and may affect cardiac function in patients with end-stage renal disease (ESRD. However, little is known about the effect of residual renal function on vascular calcification and cardiac function in patients on hemodialysis.This study was conducted between January 2014 and January 2017. One hundred six patients with residual renal function on maintenance hemodialysis for 3 months were recruited. We used residual renal urea clearance (KRU to measure residual renal function. First, abdominal aortic calcification score (AACS and brachial-ankle pulse wave velocity (baPWV were measured in patients on hemodialysis. Second, we performed echocardiography and investigated new cardiovascular events after study enrollment.The median KRU was 0.9 (0.3-2.5 mL/min/1.73m2. AACS (4.0 [1.0-10.0] vs. 3.0 [0.0-8.0], p = 0.05 and baPWV (1836.1 ± 250.4 vs. 1676.8 ± 311.0 cm/s, p = 0.01 were significantly higher in patients with a KRU < 0.9 mL/min/1.73m2 than a KRU ≥ 0.9 mL/min/1.73m2. Log-KRU significantly negatively correlated with log-AACS (ß = -0.29, p = 0.002 and baPWV (ß = -0.19, P = 0.05 after factor adjustment. The proportion of left ventricular diastolic dysfunction was significantly higher in patients with a KRU < 0.9 mL/min/1.73m2 than with a KRU ≥ 0.9 mL/min/1.73m2 (67.9% vs. 49.1%, p = 0.05. Patients with a KRU < 0.9 mL/min/1.73m2 showed a higher tendency of cumulative cardiovascular events compared to those with a KRU ≥ 0.9 ml/min/1.73m2 (P = 0.08.Residual renal function was significantly associated with vascular calcification and left ventricular diastolic dysfunction in patients on hemodialysis.

  20. Screening for estrogen residues in calf urine: Comparison of a validated yeast estrogen bioassay and gas chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Bovee, T.F.H.; Heskamp, H.H.; Lasaroms, J.J.P.; Sanders, M.B.; Rhijn, van J.A.; Groot, M.J.; Hoogenboom, L.A.P.

    2006-01-01

    Within the European Union, the control for residues of illegal hormones in food-producing animals is based on urine analysis for a few target analytes using gas chromatography/mass spectrometry and/or liquid chromatography¿tandem mass spectrometry. Recently, we developed a robust yeast bioassay

  1. Evolution of post-ESWL residual lithiasis depending on the type of calculus and urine composition.

    Science.gov (United States)

    Grases, Felix; Costa-Bauzá, Antonia; Isern, Bernat; Sanchis, Pilar; Perelló, Joan; Hierro, Fernando; Conte Visus, Antonio

    2009-07-01

    Extracorporeal shock wave lithotripsy (ESWL) is one of the most commonly used procedures for removal of renal calculi from the upper urinary tract, but complete expulsion of the fragments generated is not always achieved. This can lead to new lithiasic episodes, and it is considered that 10-26% of fragmented calculi can undergo regrowth. This in vitro study investigated the influence of fragment and urinary composition on post-ESWL growth of fragments, with the aims of establishing the effect and importance of these parameters, and identifying effective prophylactic measures. Fragments collected from patients immediately following expulsion after ESWL treatment were selected for regrowth experiments. The particles included 24 calcium oxalate monohydrate (COM) fragments, 48 calcium oxalate dihydrate (COD), 24 hydroxyapatite (HAP), and 16 uric acid. In all treatments, calculi fragments showed a considerable capacity to induce growth of calcium oxalate and calcium phosphate. Under normocalciuria conditions, new COM crystals formed; both COM and COD crystals developed under hypercalciuria conditions at a urinary pH 6.0 both HAP and brushite (BRU) crystals were formed. The highest growth rates were observed for COD calculi fragments under hypercalciuria conditions and at a urinary pH of 6.5, followed by growth on COM and HAP fragments under the same conditions; growth rates under other conditions tested were similar but 10-fold lower. With regard to the role of crystallization inhibitors, phytate exhibited inhibitory effects under all assay conditions. However, citrate had little effect, even at the highest concentration tested (1,000 mg/L). This study demonstrates the importance of avoiding heterogeneous nucleant retention (pre-existing solid microparticles) in renal cavities, as these can act as very efficient inducers of the formation of new calculi, the composition of which is mainly dependant on the urine composition.

  2. Decomposition of residual oil by large scale HSC plant

    Energy Technology Data Exchange (ETDEWEB)

    Washimi, Koichi; Ogata, Yoshitaka; Limmer, H.; Schuetter, H. (Toyo Engineering Corp., funabashi, Japan VEB Petrolchemisches Kombinat Schwedt, Schwedt (East Germany))

    1989-07-01

    Regarding large scale and high decomposition ratio visbreaker HSC, characteristic points and operation conditions of a new plant in East Germany were introduced. As for the characteristics of the process, high decomposition ratio and stable decpmposed oil, availability of high sulfur content oil or even decomposed residuum of visbreaker, stableness of produced light oil with low content of unsaturated components, low investment with low running cost, were indicated. For the realization of high decomposition ratio, designing for suppressing the decomposition in heating furnace and accelaration of it in soaking drum, high space velocity of gas phase for better agitation, were raised. As the main subject of technical development, design of soaking drum was indicated with main dimensions for the designing. Operation conditions of the process in East Germany using residual oil supplied from already working visbreaker for USSR crude oil were introduced. 6 refs., 4 figs., 2 tabs.

  3. Formation of large target residues in intermediate energy nuclear collisions

    International Nuclear Information System (INIS)

    Loveland, W.; Aleklett, K.; Sihver, L.; Xu, Z.; Seaborg, G.T.

    1987-04-01

    We have used radiochemical techniques to measure the yields, angular distributions and velocity spectra of the large (A/sub frag/ ≥ 2/3 A/sub tgt/) target residues from the fragmentation of 197 Au by intermediate energy 12 C, 20 Ne, 32 S, 40 Ar, 84 Kr, and 139 La projectiles. The fragment moving frame angular distributions are asymmetric for the lighter projectiles (C-Ar). The fragment velocity spectra are Maxwellian for the Kr induced reactions and non-Maxwellian for the reactions induced by the lighter ions. We interpret these results in terms of a change in the dominant fragment production mechanism(s) from one(s) involving a fast non-equilibrium process for the lighter ions to a slow, equilibrium process for Kr. Comparison of the measured yields and angular distributions with calculations made using a Boltzmann transport equation with appropriate modifications for Pauli blocking, etc., show excellent agreement between data and theory. 12 refs., 12 figs

  4. Glyphosate Residues in Groundwater, Drinking Water and Urine of Subsistence Farmers from Intensive Agriculture Localities: A Survey in Hopelchén, Campeche, Mexico.

    Science.gov (United States)

    Rendon-von Osten, Jaime; Dzul-Caamal, Ricardo

    2017-06-03

    The use of pesticides in Mexican agriculture creates an interest in learning about the presence of these substances in different environmental matrices. Glyphosate (GLY) is an herbicide widely used in the state of Campeche, located in the Mayan zone in the western Yucatan peninsula. Despite the fact that GLY is considered a non-toxic pesticide to humans, its presence in water bodies through spillage, runoff, and leaching are a risk to human health or biota that inhabit these ecosystems. In the present study, glyphosate residues were determined in groundwater, bottled drinking water, and the urine of subsistence farmers from various localities of the Hopelchén municipality in Campeche. Determination of GLY was carried out using Enzyme-Linked Immunosorbent Assay (ELISA). The highest concentrations of GLY were observed in the groundwater (1.42 μg/L) of Ich-Ek and urine (0.47 μg/L) samples of subsistence farmers from the Francisco J. Mújica communities. The glyphosate concentrations in groundwater and bottled drinking water indicate an exposure and excessive use of glyphosate in these agricultural communities. This is one of the first studies that reports glyphosate concentration levels in human urine and bottled drinking water in México and in the groundwater in the Yucatan Peninsula as part of a prospective pilot study, to which a follow-up will be performed to monitor this trend over time.

  5. Glyphosate Residues in Groundwater, Drinking Water and Urine of Subsistence Farmers from Intensive Agriculture Localities: A Survey in Hopelchén, Campeche, Mexico

    Directory of Open Access Journals (Sweden)

    Jaime Rendon-von Osten

    2017-06-01

    Full Text Available The use of pesticides in Mexican agriculture creates an interest in learning about the presence of these substances in different environmental matrices. Glyphosate (GLY is an herbicide widely used in the state of Campeche, located in the Mayan zone in the western Yucatan peninsula. Despite the fact that GLY is considered a non-toxic pesticide to humans, its presence in water bodies through spillage, runoff, and leaching are a risk to human health or biota that inhabit these ecosystems. In the present study, glyphosate residues were determined in groundwater, bottled drinking water, and the urine of subsistence farmers from various localities of the Hopelchén municipality in Campeche. Determination of GLY was carried out using Enzyme-Linked Immunosorbent Assay (ELISA. The highest concentrations of GLY were observed in the groundwater (1.42 μg/L of Ich-Ek and urine (0.47 μg/L samples of subsistence farmers from the Francisco J. Mújica communities. The glyphosate concentrations in groundwater and bottled drinking water indicate an exposure and excessive use of glyphosate in these agricultural communities. This is one of the first studies that reports glyphosate concentration levels in human urine and bottled drinking water in México and in the groundwater in the Yucatan Peninsula as part of a prospective pilot study, to which a follow-up will be performed to monitor this trend over time.

  6. Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anuradha Sridhar

    2012-01-01

    Full Text Available We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm ′Type A′ patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.

  7. cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Orio, Peter F III; Merrick, Gregory S; Allen, Zachariah A; Butler, Wayne M; Wallner, Kent E; Kurko, Brian S; Galbreath, Robert W

    2009-01-01

    To evaluate the impact of external beam radiation therapy (XRT) on weekly ultrasound determined post-void residual (PVR) urine volumes in patients with prostate cancer. 125 patients received XRT for clinically localized prostate cancer. XRT was delivered to the prostate only (n = 66) or if the risk of lymph node involvement was greater than 10% to the whole pelvis followed by a prostate boost (n = 59). All patients were irradiated in the prone position in a custom hip-fix mobilization device with an empty bladder and rectum. PVR was obtained at baseline and weekly. Multiple clinical and treatment parameters were evaluated as predictors for weekly PVR changes. The mean patient age was 73.9 years with a mean pre-treatment prostate volume of 53.3 cc, a mean IPSS of 11.3 and a mean baseline PVR of 57.6 cc. During treatment, PVR decreased from baseline in both cohorts with the absolute difference within the limits of accuracy of the bladder scanner. Alpha-blockers did not predict for a lower PVR during treatment. There was no significant difference in mean PVR urine volumes or differences from baseline in either the prostate only or pelvic radiation groups (p = 0.664 and p = 0.458, respectively). Patients with a larger baseline PVR (>40 cc) had a greater reduction in PVR, although the greatest reduction was seen between weeks one and three. Patients with a small PVR (<40 cc) had no demonstrable change throughout treatment. Prostate XRT results in clinically insignificant changes in weekly PVR volumes, suggesting that radiation induced bladder irritation does not substantially influence bladder residual urine volumes

  8. cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer

    Directory of Open Access Journals (Sweden)

    Wallner Kent E

    2009-07-01

    Full Text Available Abstract Background To evaluate the impact of external beam radiation therapy (XRT on weekly ultrasound determined post-void residual (PVR urine volumes in patients with prostate cancer. Methods 125 patients received XRT for clinically localized prostate cancer. XRT was delivered to the prostate only (n = 66 or if the risk of lymph node involvement was greater than 10% to the whole pelvis followed by a prostate boost (n = 59. All patients were irradiated in the prone position in a custom hip-fix mobilization device with an empty bladder and rectum. PVR was obtained at baseline and weekly. Multiple clinical and treatment parameters were evaluated as predictors for weekly PVR changes. Results The mean patient age was 73.9 years with a mean pre-treatment prostate volume of 53.3 cc, a mean IPSS of 11.3 and a mean baseline PVR of 57.6 cc. During treatment, PVR decreased from baseline in both cohorts with the absolute difference within the limits of accuracy of the bladder scanner. Alpha-blockers did not predict for a lower PVR during treatment. There was no significant difference in mean PVR urine volumes or differences from baseline in either the prostate only or pelvic radiation groups (p = 0.664 and p = 0.458, respectively. Patients with a larger baseline PVR (>40 cc had a greater reduction in PVR, although the greatest reduction was seen between weeks one and three. Patients with a small PVR ( Conclusion Prostate XRT results in clinically insignificant changes in weekly PVR volumes, suggesting that radiation induced bladder irritation does not substantially influence bladder residual urine volumes.

  9. The Cytotoxic Effect of Small and Large Molecules of PMF Fraction Extracted from Camel Urine on Cancer Cells

    KAUST Repository

    Khorshid, Faten

    2015-01-10

    Aim of the work: Animal urine, including that of camels, has long been used for the therapeutic management of human ailments. In this study, we sought to characterize the cytotoxic properties of newly derived purified fractions from previously described camel urine extract (PMF) on various cancer cell lines. Methodology: Two new size dissimilar fractions of PMF (large and small) were obtained by fractionalizing PMF using 3kD and 50kD membrane filters. A SRB cytotoxicity assay of the PMF fractions was performed on cancer cell lines (A549, HCT116, HepG2, MCF-7, U251 and Hela) as well as normal cell lines (human fibroblast cell line and Vero). Results: This study showed that the newly derived and more purified fraction of PMF (new PMF) possesses effective and selective anti-cancer properties against several types of cancer cell lines. Conclusion: This study, as well as previous ones, suggests that camel urine extracts (old and new PMF) may provide newer therapeutic alternatives to clinically manage cancer patients. However, further studies are needed to verify these positive preliminary results.

  10. Bilirubin - urine

    Science.gov (United States)

    Conjugated bilirubin - urine; Direct bilirubin - urine ... Bilirubin is not normally found in the urine. ... Increased levels of bilirubin in the urine may be due to: Biliary tract disease Cirrhosis Gallstones in the biliary tract Hepatitis Liver disease ...

  11. Comparison of Lateral Flow Assay, Kidney Inhibition Swab, and Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Penicillin G Residues in Sow Urine.

    Science.gov (United States)

    Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J

    2017-03-01

    Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.

  12. The use of saliva as a practical and feasible alternative to urine in large-scale screening for congenital cytomegalovirus infection increasesinclusion and detection rates

    Directory of Open Access Journals (Sweden)

    Emanuelle Santos de Carvalho Cardoso

    2015-04-01

    Full Text Available INTRODUCTION: Although urine is considered the gold-standard material for the detection of congenital cytomegalovirus (CMV infection, it can be difficult to obtain in newborns. The aim of this study was to compare the efficiency of detection of congenital CMV infection in saliva and urine samples. METHODS: One thousand newborns were included in the study. Congenital cytomegalovirus deoxyribonucleic acid (DNA was detected by polymerase chain reaction (PCR. RESULTS: Saliva samples were obtained from all the newborns, whereas urine collection was successful in only 333 cases. There was no statistically significant difference between the use of saliva alone or saliva and urine collected simultaneously for the detection of CMV infection. CONCLUSIONS: Saliva samples can be used in large-scale neonatal screening for CMV infection.

  13. Urine Cytology

    Science.gov (United States)

    Urine cytology Overview Urine cytology is a test to look for abnormal cells in your urine. It's used with other tests and procedures to diagnose ... bladder cancer. Your doctor might recommend a urine cytology test if you have blood in your urine ( ...

  14. Prediction of welding residual distortions of large structures using a local/global approach

    International Nuclear Information System (INIS)

    Duan, Y. G.; Bergheau, J. M.; Vincent, Y.; Boitour, F.; Leblond, J. B.

    2007-01-01

    Prediction of welding residual distortions is more difficult than that of the microstructure and residual stresses. On the one hand, a fine mesh (often 3D) has to be used in the heat affected zone for the sake of the sharp variations of thermal, metallurgical and mechanical fields in this region. On the other hand, the whole structure is required to be meshed for the calculation of residual distortions. But for large structures, a 3D mesh is inconceivable caused by the costs of the calculation. Numerous methods have been developed to reduce the size of models. A local/global approach has been proposed to determine the welding residual distortions of large structures. The plastic strains and the microstructure due to welding are supposed can be determined from a local 3D model which concerns only the weld and its vicinity. They are projected as initial strains into a global 3D model which consists of the whole structure and obviously much less fine in the welded zone than the local model. The residual distortions are then calculated using a simple elastic analysis, which makes this method particularly effective in an industrial context. The aim of this article is to present the principle of the local/global approach then show the capacity of this method in an industrial context and finally study the definition of the local model

  15. Urine culture

    Science.gov (United States)

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  16. Residual stress measurement of large scaled welded pipe using neutron diffraction method. Effect of SCC crack propagation and repair weld on residual stress distribution

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Katsuyama, Jinya; Tobita, Tohru; Morii, Yukio

    2011-01-01

    The RESA-1 neutron engineering diffractometer in the JRR-3 (Japan Research Reactor No.3) at the Japan Atomic Energy Agency, which is used for stress measurements, was upgraded to realize residual stress measurements of large scaled mechanical components. A series of residual stress measurements was made to obtain through-thickness residual stress distributions in a Type 304 stainless steel butt-welded pipe of 500A-sch.80 using the upgraded RESA-1 diffractometer. We evaluated effects of crack propagation such as stress corrosion cracking (SCC) and a part-circumference repair weld on the residual stress distributions induced by girth welding. Measured residual stress distributions near original girth weld revealed good agreement with typical results shown in some previous works using finite element method, deep hole drilling as well as neutron diffraction. After introducing a mock crack with 10 mm depth in the heat affected zone on the inside wall of the pipe by electro discharge machining, the axial residual stresses were found to be released in the part of the mock crack. However, changes in the through-wall bending stress component and the self-equilibrated stress component were negligible and hence the axial residual stress distribution in the ligament was remained in the original residual stresses near girth weld without the mock crack. Furthermore, changes in hoop and radial residual stress were also small. The residual stress distributions after a part repair welding on the outer circumference of the girth weld were significantly different from residual stress distributions near the original girth weld. The through-thickness average axial residual stress was increased due to increase of the tensile membrane stress and mitigation of the bending stress after repair welding. Throughout above studies, we evidenced that the neutron diffraction technique is useful and powerful tool for measuring residual stress distributions in large as well as thick mechanical

  17. Adsorption of Caesium in Urine on Copper Hexacyanoferrate(II) - A Contamination Control Kit for Large-Scale In-Situ Use

    International Nuclear Information System (INIS)

    Johansson, L.; Samuelsson, C.; Holm, E.

    1999-01-01

    A kit containing copper hexacyanoferrate(II) was created for large scale distribution to caesium-contaminated subjects for in situ sampling in the event of radiocaesium release from a nuclear accident of other nuclear activities. This kit is to be used for screening the internal contamination level of a population exposed to radiocaesium fallout and could be seen as a fast method of whole-body counting, suitable for large scale determinations. The separation of caesium from urine by adsorption on the copper compound was studied and it was determined that caesium efficiently adsorbed from urine. The contamination control kit is a practical alternative to urine sampling since caesium is concentrated to a small volume, by the subject using the kit in situ, gaining advantages in handling, distribution, storage and measuring geometry in the subsequent gamma ray analysis. The kit consists of cotton filters impregnated with copper hexacyanoferrate(II) held by plastic filter holders and performs a rapid flow-through. In order to obtain full caesium adsorption, less than 0.5 g of the compound is required for a 2 litre urine sample. No chemical preparation or change in pH of the urine sample is needed before adsorption. When using the kit in an authentic internal caesium contamination situation, the adsorbed fraction of caesium was 97 ± 3% (SD) in ten samples. (author)

  18. Method for Determination of Neptunium in Large-Sized Urine Samples Using Manganese Dioxide Coprecipitation and 242Pu as Yield Tracer

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel method for bioassay of large volumes of human urine samples using manganese dioxide coprecipitation for preconcentration was developed for rapid determination of 237Np. 242Pu was utilized as a nonisotopic tracer to monitor the chemical yield of 237Np. A sequential injection extraction chr...... and rapid analysis of neptunium contamination level for emergency preparedness....

  19. Research on fatigue behavior and residual stress of large-scale cruciform welding joint with groove

    International Nuclear Information System (INIS)

    Zhao, Xiaohui; Liu, Yu; Liu, Yong; Gao, Yuan

    2014-01-01

    Highlights: • The fatigue behavior of the large-scale cruciform welding joint with groove was studied. • The longitudinal residual stress of the large-scale cruciform welding joint was tested by contour method. • The fatigue fracture mechanism of the large-scale cruciform welding joint with groove was analyzed. - Abstract: Fatigue fracture behavior of the 30 mm thick Q460C-Z steel cruciform welded joint with groove was investigated. The fatigue test results indicated that fatigue strength of 30 mm thick Q460C-Z steel cruciform welded joint with groove can reach fatigue level of 80 MPa (FAT80). Fatigue crack source of the failure specimen initiated from weld toe. Meanwhile, the microcrack was also found in the fusion zones of the fatigue failure specimen, which was caused by weld quality and weld metal integrity resulting from the multi-pass welds. Two-dimensional map of the longitudinal residual stress of 30 mm thick Q460C-Z steel cruciform welded joint with groove was obtained by using the contour method. The stress nephogram of Two-dimensional map indicated that longitudinal residual stress in the welding center is the largest

  20. The Cytotoxic Effect of Small and Large Molecules of PMF Fraction Extracted from Camel Urine on Cancer Cells

    KAUST Repository

    Khorshid, Faten; Emwas, Abdul-Hamid M.; Mahboub, Faiza

    2015-01-01

    Conclusion: This study, as well as previous ones, suggests that camel urine extracts (old and new PMF) may provide newer therapeutic alternatives to clinically manage cancer patients. However, further studies are needed to verify these positive preliminary results.

  1. Clean-lifting transfer of large-area residual-free graphene films.

    Science.gov (United States)

    Wang, Di-Yan; Huang, I-Sheng; Ho, Po-Hsun; Li, Shao-Sian; Yeh, Yun-Chieh; Wang, Duan-Wei; Chen, Wei-Liang; Lee, Yu-Yang; Chang, Yu-Ming; Chen, Chia-Chun; Liang, Chi-Te; Chen, Chun-Wei

    2013-08-27

    A unique "clean-lifting transfer" (CLT) technique that applies a controllable electrostatic force to transfer large-area and high-quality CVD-grown graphene onto various rigid or flexible substrates is reported. The CLT technique without using any organic support or adhesives can produce residual-free graphene films with large-area processability, and has great potential for future industrial production of graphene-based electronics or optoelectronics. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Clinical Implications of Residual Urine in Korean Benign Prostatic Hyperplasia (BPH) Patients: A Prognostic Factor for BPH-Related Clinical Events.

    Science.gov (United States)

    Ko, Young Hwii; Chae, Ji Yun; Jeong, Seung Min; Kang, Jae Il; Ahn, Hong Jae; Kim, Hyung Woo; Kang, Sung Gu; Jang, Hoon Ah; Cheon, Jun; Kim, Je Jong; Lee, Jeong Gu

    2010-12-01

    Although post-void residual urine (PVR) is frequently utilized clinically in patients with benign prostatic hyperplasia (BPH), mainly because of its procedural simplicity, its role as a clinical prognostic factor, predictive of treatment goals, is still under much dispute. We investigated the predictive value of PVR for BPH-related clinical events including surgery, acute urinary retention (AUR), and admission following urinary tract infection (UTI). From January to June of 2006, patients over 50 years of age who were diagnosed with BPH for the first time at the outpatient clinic and were then treated for at least 3 years with medications were enrolled in this study. The variables of patients who underwent surgical intervention for BPH, had occurrences of AUR, or required admission due to UTI (Group 1, n=43) were compared with those of patients who were maintained with medications only (Group 2, n=266). Group 1 had a significantly higher PVR, more severe symptoms, and a larger prostate at the time of the initial diagnosis in both the univariate and the multivariate analysis. In the 39 patients who underwent BPH-related surgery, although there was a significant change in Qmax at the time of surgery (mean, 13.1 months), PVR and the symptom score remained unchanged compared with the initial evaluation. In the receiver-operating characteristic curve analysis, the area under the curve of Group 1 was in the order of prostate volume (0.834), PVR (0.712), and symptom score (0.621). When redivided by arbitrarily selected PVR cutoffs of 50 mL, 100 mL, and 150 mL, the relative risk of clinical BPH progression was measured as 3.93, 2.61, and 2.11. These data indicate that, in the symptomatic Korean population, increased PVR at baseline is a significant indicator of BPH-related clinical events along with increased symptom score or prostate volume.

  3. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  4. A RIKILT yeast estrogen bioassay (REA) for estrogen residue detection in urine of calves experimentally treated with 17ß-estradiol

    NARCIS (Netherlands)

    Divari, S.; Maria, De R.; Cannizzo, F.T.; Spada, F.; Mulasso, C.; Bovee, T.F.H.; Capra, P.; Leporati, M.; Biolatti, B.

    2010-01-01

    17ß-Estradiol is one of the most powerful sex steroids illegally used in bovine production. The objective of this study was to evaluate the application and the specificity of the RIKILT yeast estrogen bioassay (REA) for the detection of molecules with estrogenic activities in the urine of calves

  5. Comparison of lateral flow assay, kidney inhibition swab, and liquid chromatography-tandem mass spectrometry for the detection of penicillin G residues in sow urine

    Science.gov (United States)

    Sows (n=126) were administered penicillin G procaine at 5x the label dose for 3 consecutive days. Eighteen sows were slaughtered on each withdrawal days, 5, 10, 15, 20, 25, 32, or 39 d after treatment. Urine samples were collected at slaughter and were frozen at -80 °C until screening as positive ...

  6. Urine Odor

    Science.gov (United States)

    ... doctor. Brunzel NA. Physical examination of urine. In: Fundamentals of Urine and Body Fluid Analysis. 3rd ed. St. Louis, Mo.: Saunders Elsevier; 2013:97. McPherson RA, et al., eds. Henry's Clinical Diagnosis and Management by Laboratory Methods. 23rd ed. St. Louis, Mo.: ...

  7. Large teleseismic P-wave residuals observed at the Alban Hills volcano, Central Italy

    Directory of Open Access Journals (Sweden)

    H. Mahadeva Iyer

    1994-06-01

    Full Text Available We collected teleseismic waveforms from a digital microseismic network deployed by the Istituto Nazionale di Geofisica (ING in collaboration with the U.S. Geological Survey (USGS, on the Alban Hills Quaternary volcano during the 1989-1990 seismic swann. About 50 events were recorded by the network, 30 of them by at least 4 stations. We analysed the data in order to image crustal heterogeneities beneath the volcano. The results show large delay time residuals up to - 1 second for stations located on the volcano with respect to station CP9 of the National Seismic Network located about 20 km to the east, on the Apennines. This suggests that the whole area overlies a broad low-velocity region. Although the ray coverage is not very dense, we model the gross seismic structure beneath the volcano by inverting the teleseismic relative residuals with the ACH technique. The main features detected by tbc inversion are a low-velocity zone beneath the southwestern fiank of tbc volcano, and a high-velocity region beneath the center. The depth extension of these anomalous zones ranges between 5 and 16 km. The correspondence between the low-velocity region and the most recent activity of the volcano (- 0.027 Ma leads us to infer the presence of a still hot magmatic body in the crust beneath the southwestern side of the volcano, whereas the central part overlies the older and colder high-velocity volcanic roots related to the previous central activity (0.7 to 0.3 Ma.

  8. ELISA for the core protein of the cartilage large aggregating proteoglycan, aggrecan: comparison with the concentrations of immunogenic keratan sulphate in synovial fluid, serum and urine

    DEFF Research Database (Denmark)

    Møller, H J; Larsen, F S; Ingemann-Hansen, T

    1994-01-01

    ELISA. The within-assay and between-assay coefficients of variation were 4.9-8.9% and 11.1-13.0%, respectively. The mean concentrations of core protein in synovial fluid, serum and urine were 76.4 micrograms/ml, 104.0 ng/ml and 81.0 ng/ml, respectively. In synovial fluids the concentrations were closely......Immunological assays for fragments of the cartilage large aggregating proteoglycan, aggrecan, have been widely used to monitor cartilage turnover. These assays have commonly employed the monoclonal keratan sulphate antibody, 5D4. Keratan sulphate, however, is present in many tissues and 5D4...

  9. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  10. Urine Preservative

    Science.gov (United States)

    Smith, Scott M. (Inventor); Nillen, Jeannie (Inventor)

    2001-01-01

    Disclosed is CPG, a combination of a chlorhexidine salt (such as chlorhexidine digluconate, chlorhexidine diacetate, or chlorhexidine dichloride) and n-propyl gallate that can be used at ambient temperatures as a urine preservative.

  11. Urine Color

    Science.gov (United States)

    ... drugs can darken urine, including the antimalarial drugs chloroquine and primaquine, the antibiotics metronidazole (Flagyl) and nitrofurantoin ( ... Mayo Clinic Footer Legal Conditions and Terms Any use of this site constitutes your agreement to the ...

  12. Immunoelectrophoresis - urine

    Science.gov (United States)

    ... from an infant, you may need extra collection bags. How the Test will Feel The test involves ... urine, it normally consists of mainly albumin. Normal value ranges may vary slightly among different laboratories. Talk ...

  13. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  14. Calcium - urine

    Science.gov (United States)

    ... Female urinary tract Male urinary tract Calcium urine test References Bringhurst FR, Demay MB, Kronenberg HM. Hormones and disorders of mineral metabolism. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; ...

  15. Antimicrobial residues in animal waste and water resources proximal to large-scale swine and poultry feeding operations

    Science.gov (United States)

    Campagnolo, E.R.; Johnson, K.R.; Karpati, A.; Rubin, C.S.; Kolpin, D.W.; Meyer, M.T.; Esteban, J. Emilio; Currier, R.W.; Smith, K.; Thu, K.M.; McGeehin, M.

    2002-01-01

    Expansion and intensification of large-scale animal feeding operations (AFOs) in the United States has resulted in concern about environmental contamination and its potential public health impacts. The objective of this investigation was to obtain background data on a broad profile of antimicrobial residues in animal wastes and surface water and groundwater proximal to large-scale swine and poultry operations. The samples were measured for antimicrobial compounds using both radioimmunoassay and liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS) techniques. Multiple classes of antimicrobial compounds (commonly at concentrations of >100 μg/l) were detected in swine waste storage lagoons. In addition, multiple classes of antimicrobial compounds were detected in surface and groundwater samples collected proximal to the swine and poultry farms. This information indicates that animal waste used as fertilizer for crops may serve as a source of antimicrobial residues for the environment. Further research is required to determine if the levels of antimicrobials detected in this study are of consequence to human and/or environmental ecosystems. A comparison of the radioimmunoassay and LC/ESI-MS analytical methods documented that radioimmunoassay techniques were only appropriate for measuring residues in animal waste samples likely to contain high levels of antimicrobials. More sensitive LC/ESI-MS techniques are required in environmental samples, where low levels of antimicrobial residues are more likely.

  16. Antimicrobial residues in animal waste and water resources proximal to large-scale swine and poultry feeding operations.

    Science.gov (United States)

    Campagnolo, Enzo R; Johnson, Kammy R; Karpati, Adam; Rubin, Carol S; Kolpin, Dana W; Meyer, Michael T; Esteban, J Emilio; Currier, Russell W; Smith, Kathleen; Thu, Kendall M; McGeehin, Michael

    2002-11-01

    Expansion and intensification of large-scale animal feeding operations (AFOs) in the United States has resulted in concern about environmental contamination and its potential public health impacts. The objective of this investigation was to obtain background data on a broad profile of antimicrobial residues in animal wastes and surface water and groundwater proximal to large-scale swine and poultry operations. The samples were measured for antimicrobial compounds using both radioimmunoassay and liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS) techniques. Multiple classes of antimicrobial compounds (commonly at concentrations of > 100 microg/l) were detected in swine waste storage lagoons. In addition, multiple classes of antimicrobial compounds were detected in surface and groundwater samples collected proximal to the swine and poultry farms. This information indicates that animal waste used as fertilizer for crops may serve as a source of antimicrobial residues for the environment. Further research is required to determine if the levels of antimicrobials detected in this study are of consequence to human and/or environmental ecosystems. A comparison of the radioimmunoassay and LC/ESI-MS analytical methods documented that radioimmunoassay techniques were only appropriate for measuring residues in animal waste samples likely to contain high levels of antimicrobials. More sensitive LC/ESI-MS techniques are required in environmental samples, where low levels of antimicrobial residues are more likely.

  17. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  18. Human exposure assessment to a large set of polymer additives through the analysis of urine by solid phase extraction followed by ultra high performance liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Pouech, Charlène; Kiss, Agneta; Lafay, Florent; Léonard, Didier; Wiest, Laure; Cren-Olivé, Cécile; Vulliet, Emmanuelle

    2015-12-04

    Polymer items are extensively present in the human environment. Humans may be consequently exposed to some compounds, such as additives, incorporated in these items. The objective of this work is to assess the human exposure to the main additives such as those authorized in the packaging for pharmaceutical products. The urinary matrix was selected to optimally answer this challenge because it has already been proven that the exposure to chemicals can be revealed by the analysis of this biological matrix. A multi-residue analytical method for the trace analysis at ng/mL in human urine was developed, and consisted of an extraction of analytes from urine by solid phase extraction (SPE) and an analysis by ultra-high performance liquid chromatography coupled to a tandem mass spectrometer (UHPLC-MS/MS). Even if the quantification of these compounds was an analytical challenge because of (i) the presence of these substances in the analytical process, (ii) the diversity of their physicochemical properties, and (iii) the complexity of the matrix, the optimized method exhibited quantification limits lower than 25ng/mL and recoveries between 51% and 120% for all compounds. The method was validated and applied to 52 human urines. To the best of our knowledge, this work presents the first study allowing the assessment of the occurrence of more than twenty polymer additives at ng/mL in human urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Modeling long-term carbon residue in the ocean-atmosphere system following large CO2 emissions

    Science.gov (United States)

    Towles, N. J.; Olson, P.; Gnanadesikan, A.

    2013-12-01

    We use the LOSCAR carbon cycle model (Zeebe et al., 2009; Zeebe, 2012) to calculate the residual carbon in the ocean and atmosphere following large CO2 emissions. We consider the system response to CO2 emissions ranging from 100 to 20000 PgC, and emission durations from 100 yr to 100 kyr, subject to a wide range of system parameters such as the strengths of silicate weathering and the oceanic biological carbon pump. We define the carbon gain factor as the ratio of residual carbon in the ocean-atmosphere to the total emitted carbon. For moderate sized emissions shorter than about 50 kyr, we find that the carbon gain factor grows during the emission and peaks at about 1.7, primarily due to the erosion of carbonate marine sediments. In contrast, for longer emissions, the carbon gain factor peaks at a smaller value, and for very large emissions (more than 5000 PgC), the gain factor decreases with emission size due to carbonate sediment exhaustion. This gain factor is sensitive to model parameters such as low latitude efficiency of the biological pump. The timescale for removal of the residual carbon (reducing the carbon gain factor to zero) depends strongly on the assumed sensitivity of silicate weathering to atmospheric pCO2, and ranges from less than one million years to several million years.

  20. The Human Urine Metabolome

    Science.gov (United States)

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing

  1. Nutrient and energy recovery from urine

    NARCIS (Netherlands)

    Kuntke, P.

    2013-01-01

    Keywords: urine, urine treatment, nutrient recovery, microbial fuel cells, energy production from urine, membrane capacitive deionization.

    In conventional wastewater treatment plants large amounts of energy are required for the removal and recovery of nutrients (i.e. nitrogen and

  2. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  3. A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine.

    Science.gov (United States)

    Locatelli, Marcello; Kabir, Abuzar; Innosa, Denise; Lopatriello, Teresa; Furton, Kenneth G

    2017-01-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of twelve azole antimicrobial drug residues that include ketoconazole, terconazole, voriconazole, bifonazole, clotrimazole, tioconazole, econazole, butoconazole, miconazole, posaconazole, ravuconazole, and itraconazole in human plasma and urine samples. The selected azole antimicrobial drugs were well resolved by using a Luna C 18 column (250mm×4.6mm; 5μm particle size) in gradient elution mode within 36min. The analytical method was calibrated and validated in the range from 0.1 to 8μg/mL for all the drug compounds. Blank human plasma and urine were used as the sample matrix for the analysis; while benzyl-4-hydroxybenzoate was used as the internal standard (IS). The limit of quantification of the FPSE-HPLC-PDA method was found as 0.1μg/mL and the weighted-matrix matched standard calibration curves of the drugs showed a good linearity upto a concentration of 8μg/mL. The parallelism tests were also performed to evaluate whether overrange sample can be analyzed after dilution, without compromising the analytical performances of the validated method. The intra- and inter-day precision (RSD%) values were found ≤13.1% and ≤13.9%, respectively. The intra- and inter-day trueness (bias%) values were found in the range from -12.1% to 10.5%. The performances of the validated FPSE-HPLC-PDA were further tested on real samples collected from healthy volunteers after a single dose administration of itraconazole and miconazole. To the best of our knowledge, this is the first FPSE extraction procedure applied on plasma and urine samples for the simultaneous determination of twelve azole drugs possessing a wide range of logK ow values (extending from 0.4 for fluconazole to 6.70 of butoconazole) and could be adopted as a rapid and robust green analytical tool for clinical and

  4. Role of residual layer and large-scale phenomena on the evolution of the boundary layer

    NARCIS (Netherlands)

    Blay, E.; Pino, D.; Vilà-Guerau de Arellano, J.; Boer, van de A.; Coster, de O.; Faloona, I.; Garrouste, O.; Hartogensis, O.K.

    2012-01-01

    Mixed-layer theory and large-eddy simulations are used to analyze the dynamics of the boundary layer on two intensive operational periods during the Boundary Layer Late Afternoon and Sunset Turbulence (BLLAST) campaign: 1st and 2nd of July 2011, when convective boundary layers (CBLs) were observed.

  5. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  6. Determination of residual oil saturation from time-lapse pulsed neutron capture logs in a large sandstone reservoir

    International Nuclear Information System (INIS)

    Syed, E.V.; Salaita, G.N.; McCaffery, F.G.

    1991-01-01

    Cased hole logging with pulsed neutron tools finds extensive use for identifying zones of water breakthrough and monitoring oil-water contacts in oil reservoirs being depleted by waterflooding or natural water drive. Results of such surveys then find direct use for planning recompletions and water shutoff treatments. Pulsed neutron capture (PNC) logs are useful for estimating water saturation changes behind casing in the presence of a constant, high-salinity environment. PNC log surveys run at different times, i.e., in a time-lapse mode, are particularly amenable to quantitative analysis. The combined use of the original open hole and PNC time-lapse log information can then provide information on remaining or residual oil saturations in a reservoir. This paper reports analyses of historical pulsed neutron capture log data to assess residual oil saturation in naturally water-swept zones for selected wells from a large sandstone reservoir in the Middle East. Quantitative determination of oil saturations was aided by PNC log information obtained from a series of tests conducted in a new well in the same field

  7. Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Tetracycline Residues in Milk

    Directory of Open Access Journals (Sweden)

    Gabriela Islas

    2018-01-01

    Full Text Available Solid-phase extraction in combination with large-volume sample stacking-capillary electrophoresis (SPE-LVSS-CE was applied to measure chlortetracycline, doxycycline, oxytetracycline, and tetracycline in milk samples. Under optimal conditions, the proposed method had a linear range of 29 to 200 µg·L−1, with limits of detection ranging from 18.6 to 23.8 µg·L−1 with inter- and intraday repeatabilities < 10% (as a relative standard deviation in all cases. The enrichment factors obtained were from 50.33 to 70.85 for all the TCs compared with a conventional capillary zone electrophoresis (CZE. This method is adequate to analyze tetracyclines below the most restrictive established maximum residue limits. The proposed method was employed in the analysis of 15 milk samples from different brands. Two of the tested samples were positive for the presence of oxytetracycline with concentrations of 95 and 126 µg·L−1. SPE-LVSS-CE is a robust, easy, and efficient strategy for online preconcentration of tetracycline residues in complex matrices.

  8. Chemical Control of Black Flies in Large Rivers as an Impact in Agrochemical Residue-Biota Interactions in Water Ecosystems

    International Nuclear Information System (INIS)

    Haufe, W.O.

    1981-01-01

    Livestock losses have been an obstacle to economic development of the farming and livestock industry in more northerly areas of Canada until two species of black fly, Simulium arcticum and S. luggeri, outbreaks are controlled effectively. The problem is complicated by its association with an abundance of large rivers and streams. Since effective control of black flies is presently limited to reduction of their breeding sources in flowing water, the managers of Canadian inland waters have been concerned about any major practice of using pesticides as black fly larvicides. Consequently, Canadian inland waters have been subject to continuous monitoring of major drainage systems with special attention to the chlorinated hydrocarbon insecticides. The latest status of residues was published from a Canadian Survey of 333 sampling locations between 1972 and 1975

  9. The urine marker test

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Jensen, Stine Nylandsted; Elsborg, Peter

    2016-01-01

    BACKGROUND: Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured...... that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs......) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. OBJECTIVE: The objective of this study was to investigate the use of the urine marker during urine doping control testing. METHODS: Two studies investigated athletes' acceptance...

  10. Large-scale evaluation of dynamically important residues in proteins predicted by the perturbation analysis of a coarse-grained elastic model

    Directory of Open Access Journals (Sweden)

    Tekpinar Mustafa

    2009-07-01

    Full Text Available Abstract Backgrounds It is increasingly recognized that protein functions often require intricate conformational dynamics, which involves a network of key amino acid residues that couple spatially separated functional sites. Tremendous efforts have been made to identify these key residues by experimental and computational means. Results We have performed a large-scale evaluation of the predictions of dynamically important residues by a variety of computational protocols including three based on the perturbation and correlation analysis of a coarse-grained elastic model. This study is performed for two lists of test cases with >500 pairs of protein structures. The dynamically important residues predicted by the perturbation and correlation analysis are found to be strongly or moderately conserved in >67% of test cases. They form a sparse network of residues which are clustered both in 3D space and along protein sequence. Their overall conservation is attributed to their dynamic role rather than ligand binding or high network connectivity. Conclusion By modeling how the protein structural fluctuations respond to residue-position-specific perturbations, our highly efficient perturbation and correlation analysis can be used to dissect the functional conformational changes in various proteins with a residue level of detail. The predictions of dynamically important residues serve as promising targets for mutational and functional studies.

  11. Radiation protection of radioactively contaminated large areas by phytoremediation and subsequent utilization of the contaminated plant residues (PHYTOREST)

    International Nuclear Information System (INIS)

    Mirgorodsky, Daniel; Ollivier, Delphine; Merten, Dirk; Bergmann, Hans; Buechel, Georg; Willscher, Sabine; Wittig, Juliane; Jablonski, Lukasz; Werner, Peter

    2010-01-01

    Much progress has been achieved over the past 20 years in remediating sites contaminated by heavy metal. However, very large contaminated areas have presented major problems to this day because of remediation costs. Phytoremediation is a new, emerging, sustainable technique of remediating areas with low heavy-metal contamination. One advantage of phytoremediation is the comparatively low cost of the process, which may make it usable also on large areas with low levels of contamination. Besides extracting and immobilizing metals, respectively, phytoremediation among other things also contributes to improving soil quality in terms of physics, chemistry, and ecology. Consequently, phytoremediation offers a great potential for the future. Research into phytoremediation of an area contaminated by heavy metals and radionuclides is carried out on a site in a former uranium mining district in Eastern Thuringia jointly by the Friedrich Schiller University, Jena, and the Technical University of Dresden in a project funded by the German Federal Ministry for Education and Research. The project serves to promote the introduction of soft, biocompatible methods of long-term remediation and to develop conceptual solutions to the subsequent utilization of contaminated plant residues. Optimizing area management is in the focus of phytoremediation studies. (orig.)

  12. Urine specific gravity test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  13. Maple syrup urine disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000373.htm Maple syrup urine disease To use the sharing features on this page, please enable JavaScript. Maple syrup urine disease (MSUD) is a disorder in ...

  14. Urine drug screen

    Science.gov (United States)

    Drug screen - urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence may indicate that you recently used these drugs. Some drugs may remain in your system for ...

  15. Urine Tests (For Parents)

    Science.gov (United States)

    ... the urine sample. In certain situations, a sterile bag can be placed around a baby’s diaper area to collect a urine sample. If you have any questions about urine tests, talk with your doctor. Reviewed by: Yamini Durani, MD ...

  16. Large breast size as a risk factor for late adverse effects of breast radiotherapy: Is residual dose inhomogeneity, despite 3D treatment planning and delivery, the main explanation?

    International Nuclear Information System (INIS)

    Goldsmith, Christy; Haviland, Joanne; Tsang, Yat; Sydenham, Mark; Yarnold, John

    2011-01-01

    Background and Purpose: Large breast size is associated with an increased risk of late adverse effects after breast conservation surgery and radiotherapy, even when 3D dosimetry is used. The purpose of this study is to test the hypothesis that residual dose inhomogeneity is sufficient to explain the association. Methods: Patients previously treated after breast conservation surgery with whole breast radiotherapy using 3D dosimetry and followed up in the UK FAST hypofractionation trial were selected for this analysis. The residual level of dose inhomogeneity across the whole breast treatment volume was used to test for association between residual dosimetry and post-treatment change in breast appearance at 2 years post-radiotherapy. Results: At 2 years, 201/279 (72%) of women had no change in photographic breast appearance, 61 (22%) had mild change and 17 (6%) had marked change. Breast size and dosimetry were both significantly associated with late effects in univariate analyses, but only breast size remained an independent significant risk factor for change in breast appearance when included in a multiple regression model together with other prognostic factors (p = 0.006 for trend). Conclusion: Large-breasted women are more likely to suffer change in breast size and shape after whole breast radiotherapy delivered using 3D dosimetry, but residual dose inhomogeneity is insufficient to explain the association.

  17. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  18. Determination of drug residues in urine of dogs receiving anti-cancer chemotherapy by liquid chromatography-electrospray ionization- tandem mass spectrometry: is there an environmental or occupational risk?

    Science.gov (United States)

    Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela

    2010-04-01

    Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.

  19. Pink urine syndrome

    Directory of Open Access Journals (Sweden)

    Luis del Carpio-Orantes

    2017-03-01

    Full Text Available In the present images we allude to a syndrome of low incidence, characterized by pink urine, being related to factors such as obesity, and being triggered by abdominal surgeries, use of propofol, among others. Being favoured by the presence of abundant crystals of uric acid in the urine confers the typical pink coloration.

  20. Iodine and creatinine testing in urine dried on filter paper

    Energy Technology Data Exchange (ETDEWEB)

    Zava, Theodore T., E-mail: ttzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Kapur, Sonia, E-mail: soniak@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Zava, David T., E-mail: dzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States)

    2013-02-18

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R{sup 2} = 0.9483; creatinine: R{sup 2} = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs.

  1. Iodine and creatinine testing in urine dried on filter paper

    International Nuclear Information System (INIS)

    Zava, Theodore T.; Kapur, Sonia; Zava, David T.

    2013-01-01

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R 2 = 0.9483; creatinine: R 2 = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs

  2. Large-scale monitoring of effects of clothianidin-dressed oilseed rape seeds on pollinating insects in northern Germany: residues of clothianidin in pollen, nectar and honey

    OpenAIRE

    Rolke, Daniel; Persigehl, Markus; Peters, Britta; Sterk, Guido; Blenau, Wolfgang

    2016-01-01

    This study was part of a large-scale monitoring project to assess the possible effects of Elado® (10 g clothianidin & 2 g β-cyfluthrin/kg seed)-dressed oilseed rape seeds on different pollinators in Northern Germany. Firstly, residues of clothianidin and its active metabolites thiazolylnitroguanidine and thiazolylmethylurea were measured in nectar and pollen from Elado®-dressed (test site, T) and undressed (reference site, R) oilseed rape collected by honey bees confined within tunnel tents. ...

  3. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  4. Urine protein electrophoresis test

    Science.gov (United States)

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  5. Uric acid - urine

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003616.htm Uric acid urine test To use the sharing features on ... are no risks with this test. Images Uric acid test Uric acid crystals References Burns CM, Wortmann RL. Clinical ...

  6. Purple Urine Bag Syndrome

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    sudden onset, progressive left sided weakness involving both upper and ... computed tomography of the brain showed right ... included a complete blood count, renal functions which were ... Urine culture had a significant growth of Klebsiella.

  7. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples Diagnóstico de sepse neonatal causada pelo estreptococo do grupo B por meio de dupla amplificação de amostras residuais de urina

    Directory of Open Access Journals (Sweden)

    Bruno Nicolino Cezarino

    2008-03-01

    Full Text Available Group B streptococcus (GBS remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative. From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen, eight were tested by culture methods (2/8 were positive, and 8 were tested by PCR (7/8 were positive, and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR. In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid, and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all

  8. Large-scale monitoring of effects of clothianidin-dressed oilseed rape seeds on pollinating insects in northern Germany: residues of clothianidin in pollen, nectar and honey.

    Science.gov (United States)

    Rolke, Daniel; Persigehl, Markus; Peters, Britta; Sterk, Guido; Blenau, Wolfgang

    2016-11-01

    This study was part of a large-scale monitoring project to assess the possible effects of Elado ® (10 g clothianidin & 2 g β-cyfluthrin/kg seed)-dressed oilseed rape seeds on different pollinators in Northern Germany. Firstly, residues of clothianidin and its active metabolites thiazolylnitroguanidine and thiazolylmethylurea were measured in nectar and pollen from Elado ® -dressed (test site, T) and undressed (reference site, R) oilseed rape collected by honey bees confined within tunnel tents. Clothianidin and its metabolites could not be detected or quantified in samples from R fields. Clothianidin concentrations in samples from T fields were 1.3 ± 0.9 μg/kg and 1.7 ± 0.9 μg/kg in nectar and pollen, respectively. Secondly, pollen and nectar for residue analyses were sampled from free flying honey bees, bumble bees and mason bees, placed at six study locations each in the R and T sites at the start of oilseed rape flowering. Honey samples were analysed from all honey bee colonies at the end of oilseed rape flowering. Neither clothianidin nor its metabolites were detectable or quantifiable in R site samples. Clothianidin concentrations in samples from the T site were below the limit of quantification (LOQ, 1.0 µg/kg) in most pollen and nectar samples collected by bees and 1.4 ± 0.5 µg/kg in honey taken from honey bee colonies. In summary, the study provides reliable semi-field and field data of clothianidin residues in nectar and pollen collected by different bee species in oilseed rape fields under common agricultural conditions.

  9. 24-hour urine protein

    Science.gov (United States)

    ... your provider may be able to order a test that is done on just one urine sample (protein-to-creatinine ratio). Normal Results The normal ... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test ... Abnormal results may be due to: A group ...

  10. Citric acid urine test

    Science.gov (United States)

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  11. Automated color classification of urine dipstick image in urine examination

    Science.gov (United States)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  12. Urine pH test

    Science.gov (United States)

    ... urine test Male urinary tract References Bose A, Monk RD, Bushinsky DA. Kidney stones. In: Melmed S, Polonsky ... and its influence on urine pH. J Am Diet Assoc . 1995;95(7):791-797. PMID: 7797810 ...

  13. Setting up fuel supply strategies for large-scale bio-energy projects using agricultural and forest residues. A methodology for developing countries

    International Nuclear Information System (INIS)

    Junginger, M.

    2000-08-01

    The objective of this paper is to develop a coherent methodology to set up fuel supply strategies for large-scale biomass-conversion units. This method will explicitly take risks and uncertainties regarding availability and costs in relation to time into account. This paper aims at providing general guidelines, which are not country-specific. These guidelines cannot provide 'perfect fit'-solutions, but aim to give general help to overcome barriers and to set up supply strategies. It will mainly focus on residues from the agricultural and forestry sector. This study focuses on electricity or both electricity and heat production (CHP) with plant scales between 1040 MWe. This range is chosen due to rules of economies of scale. In large-scale plants the benefits of increased efficiency outweigh increased transportation costs, allowing a lower price per kWh which in turn may allow higher biomass costs. However, fuel-supply risks tend to get higher with increasing plant size, which makes it more important to assess them for large(r) conversion plants. Although the methodology does not focus on a specific conversion technology, it should be stressed that the technology must be able to handle a wide variety of biomass fuels with different characteristics because many biomass residues are not available the year round and various fuels are needed for a constant supply. The methodology allows for comparing different technologies (with known investment and operational and maintenance costs from literature) and evaluation for different fuel supply scenarios. In order to demonstrate the methodology, a case study was carried out for the north-eastern part of Thailand (Isaan), an agricultural region. The research was conducted in collaboration with the Regional Wood Energy Development Programme in Asia (RWEDP), a project of the UN Food and Agricultural Organization (FAO) in Bangkok, Thailand. In Section 2 of this paper the methodology will be presented. In Section 3 the economic

  14. Microseismic Precursory Characteristics of Rock Burst Hazard in Mining Areas Near a Large Residual Coal Pillar: A Case Study from Xuzhuang Coal Mine, Xuzhou, China

    Science.gov (United States)

    Cao, An-ye; Dou, Lin-ming; Wang, Chang-bin; Yao, Xiao-xiao; Dong, Jing-yuan; Gu, Yu

    2016-11-01

    Identification of precursory characteristics is a key issue for rock burst prevention. The aim of this research is to provide a reference for assessing rock burst risk and determining potential rock burst risk areas in coal mining. In this work, the microseismic multidimensional information for the identification of rock bursts and spatial-temporal pre-warning was investigated in a specific coalface which suffered high rock burst risk in a mining area near a large residual coal pillar. Firstly, microseismicity evolution prior to a disastrous rock burst was qualitatively analysed, and the abnormal clustering of seismic sources, abnormal variations in daily total energy release, and event counts can be regarded as precursors to rock burst. Secondly, passive tomographic imaging has been used to locate high seismic activity zones and assess rock burst hazard when the coalface passes through residual pillar areas. The results show that high-velocity or velocity anomaly regions correlated well with strong seismic activities in future mining periods and that passive tomography has the potential to describe, both quantitatively and periodically, hazardous regions and assess rock burst risk. Finally, the bursting strain energy index was further used for short-term spatial-temporal pre-warning of rock bursts. The temporal sequence curve and spatial contour nephograms indicate that the status of the danger and the specific hazardous zones, and levels of rock burst risk can be quantitatively and rapidly analysed in short time and in space. The multidimensional precursory characteristic identification of rock bursts, including qualitative analysis, intermediate and short-time quantitative predictions, can guide the choice of measures implemented to control rock bursts in the field, and provides a new approach to monitor and forecast rock bursts in space and time.

  15. Comparing the life cycle costs of using harvest residue as feedstock for small- and large-scale bioenergy systems (part II)

    International Nuclear Information System (INIS)

    Cleary, Julian; Wolf, Derek P.; Caspersen, John P.

    2015-01-01

    In part II of our two-part study, we estimate the nominal electricity generation and GHG (greenhouse gas) mitigation costs of using harvest residue from a hardwood forest in Ontario, Canada to fuel (1) a small-scale (250 kW e ) combined heat and power wood chip gasification unit and (2) a large-scale (211 MW e ) coal-fired generating station retrofitted to combust wood pellets. Under favorable operational and regulatory conditions, generation costs are similar: 14.1 and 14.9 cents per kWh (c/kWh) for the small- and large-scale facilities, respectively. However, GHG mitigation costs are considerably higher for the large-scale system: $159/tonne of CO 2 eq., compared to $111 for the small-scale counterpart. Generation costs increase substantially under existing conditions, reaching: (1) 25.5 c/kWh for the small-scale system, due to a regulation mandating the continual presence of an operating engineer; and (2) 22.5 c/kWh for the large-scale system due to insufficient biomass supply, which reduces plant capacity factor from 34% to 8%. Limited inflation adjustment (50%) of feed-in tariff rates boosts these costs by 7% to 11%. Results indicate that policy generalizations based on scale require careful consideration of the range of operational/regulatory conditions in the jurisdiction of interest. Further, if GHG mitigation is prioritized, small-scale systems may be more cost-effective. - Highlights: • Generation costs for two forest bioenergy systems of different scales are estimated. • Nominal electricity costs are 14.1–28.3 cents/kWh for the small-scale plant. • Nominal electricity costs are 14.9–24.2 cents/kWh for the large-scale plant. • GHG mitigation costs from displacing coal and LPG are $111-$281/tonne of CO 2 eq. • High sensitivity to cap. factor (large-scale) and labor requirements (small-scale)

  16. Electrolytic pretreatment of urine

    Science.gov (United States)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  17. Distribution of chloramphenicol to tissues, plasma and urine in pigs after oral intake of low doses.

    Science.gov (United States)

    Aspenström-Fagerlund, Bitte; Nordkvist, Erik; Törnkvist, Anna; Wallgren, Per; Hoogenboom, Ron; Berendsen, Bjorn; Granelli, Kristina

    2016-09-01

    Toxic effects of chloramphenicol in humans caused the ban for its use in food-producing animals in the EU. A minimum required performance level (MRPL) was specified for chloramphenicol at 0.3 μg kg(-1) for various matrices, including urine. In 2012, residues of chloramphenicol were found in pig urine and muscle without signs of illegal use. Regarding its natural occurrence in straw, it was hypothesised that this might be the source, straw being compulsory for use as bedding material for pigs in Sweden. Therefore, we investigated if low daily doses of chloramphenicol (4, 40 and 400 μg/pig) given orally during 14 days could result in residues in pig tissues and urine. A dose-related increase of residues was found in muscle, plasma, kidney and urine (showing the highest levels), but no chloramphenicol was found in the liver. At the lowest dose, residues were below the MRPL in all tissues except in the urine. However, in the middle dose, residues were above the MRPL in all tissues except muscle, and at the highest dose in all matrices. This study proves that exposure of pigs to chloramphenicol in doses occurring naturally in straw could result in residues above the MRPL in plasma, kidney and especially urine.

  18. Use of Urine Testing in Outpatients Treated for Urinary Tract Infection

    Science.gov (United States)

    Yiee, Jenny H.; Smith, Alexandria; Hanley, Janet; Saigal, Christopher S.

    2013-01-01

    OBJECTIVE: To characterize urine test use in ambulatory, antibiotic-treated pediatric urinary tract infection (UTI). METHODS: We studied children UTI and a temporally associated antibiotic prescription from 2002 through 2007 by using a large claims database, Innovus i3. We evaluated urine-testing trends and performed multivariable logistic regression to assess for factors associated with urine culture use. RESULTS: Of 40 603 treated UTI episodes in 28 678 children, urinalysis was performed in 76%, and urine culture in 57%; 32% of children UTI episode. Urine culture use decreased during the study period from 60% to 54% (P UTI and urologic anomalies were not. CONCLUSIONS: Providers often do not obtain urine tests when prescribing antibiotics for outpatient pediatric UTI. Variation in urine culture use was observed based on age, gender, and physician specialty. Additional research is necessary to determine the implications of empirical antibiotic prescription for pediatric UTI without confirmatory urine testing. PMID:23918886

  19. Technique for the Measurement of Low-Level Radioactivity of Organic Iodine in Large-Volume Urine Samples; Technique de Mesure de la Faible Radioactivite de l'Iode Organique Contenu dans des Echantillons d'Urine de Grand Volume; Metod izmereniya nizkikh aktivnostej organicheskogo joda v krupnykh obraztsakh mochi; Tecnicas de Medicion de Bajas Actividades de Yodo Organico Contenido en Muestras de Orina de Gran Volumen

    Energy Technology Data Exchange (ETDEWEB)

    Nicolesco-Zinca, D.; Matei, I. [Institut d' Endocrinologie de l' Academie Roumaine, Bucarest (Romania)

    1965-10-15

    In nuclear endocrinology there are two major problems connected with the determination of renal excretion of iodine in the form of organic compounds labelled in vitro, namely: (a) their quantitative separation from the iodide also present in urine, even if the concentration of the iodide is twenty times greater; and (b) the determination of their low-level radioactivity in large-volume urine samples, their concentration per millilitre of urine being approximately 10{sup -5} of the dose administered which, in turn, must be as low as possible. Classically, separation is carried- out by paper chromatography, for which only small samples of urine are used. This technique is laborious and requires time and equipment for chromatography. Determination of radioactivity on paper involves contamination of the entire band. In spite of correction, only 89.9% of the radioactivity is recovered, and even less when an extract of butanol is used. With the technique described by the authors, a large volume of urine sample is passed through a microcolumn of H{sup +} cation-exchange resin. The organic compounds of the radioiodine remain fixed on the cation- exchange resin and their radioactivity is measured by means of a Nal(Tl) crystal well-type scintillator. On verification for the given conditions, we found the recovery of the urine diiodotyrosine complete, with a standard error averaging 0.42% for 10 experiments. This method has been used for determining the deiodation of diiodotyrosine in 11 patients with normal deiodation and in 10 cretins with goitre, of whom five showed a deficiency of deiodation. The dose administered was 1 {mu}Ci of diiodotyrosine{sup -131}L The method allows for the administration of a radioactive dose at least 50 times lower than in classical methods, and makes possible the separation of diiodotyrosine and its recovery from a sample of 40-50 ml of urine (with a standard error of 0.42% in a period of a few hours) using Nal(Tl) well-type crystal

  20. Cortisol in urine and saliva

    DEFF Research Database (Denmark)

    Hurwitz Eller, N; Netterstrøm, B; Hansen, Åse Marie

    2001-01-01

    The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis.......The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis....

  1. Residual stresses

    International Nuclear Information System (INIS)

    Sahotra, I.M.

    2006-01-01

    The principal effect of unloading a material strained into the plastic range is to create a permanent set (plastic deformation), which if restricted somehow, gives rise to a system of self-balancing within the same member or reaction balanced by other members of the structure., known as residual stresses. These stresses stay there as locked-in stresses, in the body or a part of it in the absence of any external loading. Residual stresses are induced during hot-rolling and welding differential cooling, cold-forming and extruding: cold straightening and spot heating, fabrication and forced fitting of components constraining the structure to a particular geometry. The areas which cool more quickly develop residual compressive stresses, while the slower cooling areas develop residual tensile stresses, and a self-balancing or reaction balanced system of residual stresses is formed. The phenomenon of residual stresses is the most challenging in its application in surface modification techniques determining endurance mechanism against fracture and fatigue failures. This paper discusses the mechanism of residual stresses, that how the residual stresses are fanned and what their behavior is under the action of external forces. Such as in the case of a circular bar under limit torque, rectangular beam under limt moment, reclaiming of shafts welds and peening etc. (author)

  2. Residual stresses

    International Nuclear Information System (INIS)

    Macherauch, E.

    1978-01-01

    Residual stresses are stresses which exist in a material without the influence of external powers and moments. They come into existence when the volume of a material constantly changes its form as a consequence of mechanical, thermal, and/or chemical processes and is hindered by neighbouring volumes. Bodies with residual stress are in mechanical balance. These residual stresses can be manifested by means of all mechanical interventions disturbing this balance. Acoustical, optical, radiological, and magnetical methods involving material changes caused by residual stress can also serve for determining residual stress. Residual stresses have an ambivalent character. In technical practice, they are feared and liked at the same time. They cause trouble because they can be the cause for unexpected behaviour of construction elements. They are feared since they can cause failure, in the worst case with catastrophical consequences. They are appreciated, on the other hand, because, in many cases, they can contribute to improvements of the material behaviour under certain circumstances. But they are especially liked for their giving convenient and (this is most important) mostly uncontrollable explanations. For only in very few cases we have enough knowledge and possibilities for the objective evaluation of residual stresses. (orig.) [de

  3. Determination of natural uranium in urine (233U)

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    A procedure for the quantitative analysis of uranium in urine is described. The residue obtained by mineralization is dissolved in diluted hydrochloric acid. Uranium is separated by fixation on a permutit 50 column, elution with 0,2 M oxalic acid and electrodeposition on nickel. Uranium is then measured by α counting. It is thus possible to detect less than 1 pico-curie of uranium in the sample. (author) [fr

  4. Catecholamines, Plasma and Urine Test

    Science.gov (United States)

    ... and Iron-binding Capacity (TIBC, UIBC) Trichomonas Testing Triglycerides Troponin Tryptase Tumor Markers Uric Acid Urinalysis Urine ... blood pressure, and epinephrine increases heart rate and metabolism . After completing their actions, catecholamines are metabolized to ...

  5. Urine biomarkers in the early stages of diseases: current status and perspective.

    Science.gov (United States)

    Jing, Jian; Gao, Youhe

    2018-02-01

    As a noninvasive and easily available biological fluid, the urine is becoming an important source for disease biomarker study. Change is essential for the usefulness of a biomarker. Without homeostasis mechanisms, urine can accommodate more changes, especially in the early stages of diseases. In this review, we summarize current status and discuss perspectives on the discovery of urine biomarkers in the early stages of diseases. We emphasize the advantages of urine biomarkers compared to plasma biomarkers for the diagnosis of diseases at early stages, propose a urine biomarker research roadmap, and highlight a novel membrane storage technique that enables large-scale urine sample collection and storage efficiently and economically. It is anticipated that urine biomarker studies will greatly promote early diagnosis, prevention, treatment, and prognosis of a variety of diseases, and provide strong support for translational and precision medicine.

  6. Welding simulation of large-diameter thick-walled stainless steel pipe joints. Fast computation of residual stress and influence of heat source model

    International Nuclear Information System (INIS)

    Maekawa, Akira; Serizawa, Hisashi; Nakacho, Keiji; Murakawa, Hidekazu

    2011-01-01

    There are many weld zones in the apparatus and piping installed in nuclear power plants and residual stress generated in the zone by weld process is the most important influence factor for maintaining structural integrity. Though the weld residual stress is frequently evaluated using numerical simulation, fast simulation techniques have been demanded because of the enormous calculation times used. Recently, the fast weld residual stress evaluation based on three-dimensional accurate analysis became available through development of the Iterative Substructure Method (ISM). In this study, the computational performance of the welding simulation code using the ISM was improved to get faster computations and more accurate welding simulation. By adding functions such as parallel processing, the computation speed was much faster than that of the conventional finite element method code. Furthermore, the accuracy of the improved code was validated by measurements. The influence of two different weld heat source models on the simulation results was also investigated and it was found that the moving heat source was effective to achieve accurate weld simulation for multi-pass welds. (author)

  7. The One-carbon Carrier Methylofuran from Methylobacterium extorquens AM1 Contains a Large Number of α- and γ-Linked Glutamic Acid Residues*

    Science.gov (United States)

    Hemmann, Jethro L.; Saurel, Olivier; Ochsner, Andrea M.; Stodden, Barbara K.; Kiefer, Patrick; Milon, Alain; Vorholt, Julia A.

    2016-01-01

    Methylobacterium extorquens AM1 uses dedicated cofactors for one-carbon unit conversion. Based on the sequence identities of enzymes and activity determinations, a methanofuran analog was proposed to be involved in formaldehyde oxidation in Alphaproteobacteria. Here, we report the structure of the cofactor, which we termed methylofuran. Using an in vitro enzyme assay and LC-MS, methylofuran was identified in cell extracts and further purified. From the exact mass and MS-MS fragmentation pattern, the structure of the cofactor was determined to consist of a polyglutamic acid side chain linked to a core structure similar to the one present in archaeal methanofuran variants. NMR analyses showed that the core structure contains a furan ring. However, instead of the tyramine moiety that is present in methanofuran cofactors, a tyrosine residue is present in methylofuran, which was further confirmed by MS through the incorporation of a 13C-labeled precursor. Methylofuran was present as a mixture of different species with varying numbers of glutamic acid residues in the side chain ranging from 12 to 24. Notably, the glutamic acid residues were not solely γ-linked, as is the case for all known methanofurans, but were identified by NMR as a mixture of α- and γ-linked amino acids. Considering the unusual peptide chain, the elucidation of the structure presented here sets the basis for further research on this cofactor, which is probably the largest cofactor known so far. PMID:26895963

  8. The One-carbon Carrier Methylofuran from Methylobacterium extorquens AM1 Contains a Large Number of α- and γ-Linked Glutamic Acid Residues.

    Science.gov (United States)

    Hemmann, Jethro L; Saurel, Olivier; Ochsner, Andrea M; Stodden, Barbara K; Kiefer, Patrick; Milon, Alain; Vorholt, Julia A

    2016-04-22

    Methylobacterium extorquens AM1 uses dedicated cofactors for one-carbon unit conversion. Based on the sequence identities of enzymes and activity determinations, a methanofuran analog was proposed to be involved in formaldehyde oxidation in Alphaproteobacteria. Here, we report the structure of the cofactor, which we termed methylofuran. Using an in vitro enzyme assay and LC-MS, methylofuran was identified in cell extracts and further purified. From the exact mass and MS-MS fragmentation pattern, the structure of the cofactor was determined to consist of a polyglutamic acid side chain linked to a core structure similar to the one present in archaeal methanofuran variants. NMR analyses showed that the core structure contains a furan ring. However, instead of the tyramine moiety that is present in methanofuran cofactors, a tyrosine residue is present in methylofuran, which was further confirmed by MS through the incorporation of a (13)C-labeled precursor. Methylofuran was present as a mixture of different species with varying numbers of glutamic acid residues in the side chain ranging from 12 to 24. Notably, the glutamic acid residues were not solely γ-linked, as is the case for all known methanofurans, but were identified by NMR as a mixture of α- and γ-linked amino acids. Considering the unusual peptide chain, the elucidation of the structure presented here sets the basis for further research on this cofactor, which is probably the largest cofactor known so far. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Rediscovery of an old article reporting that the area around the epicenter in Hiroshima was heavily contaminated with residual radiation, indicating that exposure doses of A-bomb survivors were largely underestimated.

    Science.gov (United States)

    Sutou, Shizuyo

    2017-09-01

    The A-bomb blast released a huge amount of energy: thermal radiation (35%), blast energy (50%), and nuclear radiation (15%). Of the 15%, 5% was initial radiation released within 30 s and 10% was residual radiation, the majority of which was fallout. Exposure doses of hibakusha (A-bomb survivors) were estimated solely on the basis of the initial radiation. The effects of the residual radiation on hibakusha have been considered controversial; some groups assert that the residual radiation was negligible, but others refute that assertion. I recently discovered a six-decade-old article written in Japanese by a medical doctor, Gensaku Obo, from Hiroshima City. This article clearly indicates that the area around the epicenter in Hiroshima was heavily contaminated with residual radiation. It reports that non-hibakusha who entered Hiroshima soon after the blast suffered from severe acute radiation sickness, including burns, external injuries, fever, diarrhea, skin bleeding, sore throat and loss of hair-as if they were real hibakusha. This means that (i) some of those who entered Hiroshima in the early days after the blast could be regarded as indirect hibakusha; (ii) 'in-the-city-control' people in the Life Span Study (LSS) must have been irradiated more or less from residual radiation and could not function properly as the negative control; (iii) exposure doses of hibakusha were largely underestimated; and (iv) cancer risk in the LSS was largely overestimated. Obo's article is very important to understand the health effects of A-bombs so that the essence of it is translated from Japanese to English with the permission of the publisher. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  10. Rediscovery of an old article reporting that the area around the epicenter in Hiroshima was heavily contaminated with residual radiation, indicating that exposure doses of A-bomb survivors were largely underestimated

    International Nuclear Information System (INIS)

    Sutou, Shizuyo

    2017-01-01

    The A-bomb blast released a huge amount of energy: thermal radiation (35%), blast energy (50%), and nuclear radiation (15%). Of the 15%, 5% was initial radiation released within 30 s and 10% was residual radiation, the majority of which was fallout. Exposure doses of hibakusha (A-bomb survivors) were estimated solely on the basis of the initial radiation. The effects of the residual radiation on hibakusha have been considered controversial; some groups assert that the residual radiation was negligible, but others refute that assertion. I recently discovered a six-decade-old article written in Japanese by a medical doctor, Gensaku Obo, from Hiroshima City. This article clearly indicates that the area around the epicenter in Hiroshima was heavily contaminated with residual radiation. It reports that non-hibakusha who entered Hiroshima soon after the blast suffered from severe acute radiation sickness, including burns, external injuries, fever, diarrhea, skin bleeding, sore throat and loss of hair—as if they were real hibakusha. This means that (i) some of those who entered Hiroshima in the early days after the blast could be regarded as indirect hibakusha; (ii) ‘in-the-city-control’ people in the Life Span Study (LSS) must have been irradiated more or less from residual radiation and could not function properly as the negative control; (iii) exposure doses of hibakusha were largely underestimated; and (iv) cancer risk in the LSS was largely overestimated. Obo's article is very important to understand the health effects of A-bombs so that the essence of it is translated from Japanese to English with the permission of the publisher.

  11. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  12. Radioimmunological detection of vasopressin in urine extracts

    International Nuclear Information System (INIS)

    Buengner, R.

    1983-01-01

    After initial measures had been taken to ensure that ion exchange chromatography would yield a sufficiently high recovery of labelled and non-labelled hormone as well as to eliminate all intervening factors it was possible to use the described extraction procedure in connection with the RIA introduced by Freisenhausen et al. At the clinical level, the technique was employed to assess the post-operative release of AVP (argenine vasopressin) in 24-hour urine samples obtained from patients subjected to hypophysectomy. In a total of 10 patients, where hypophysectomy had been performed for different clinical reasons, the AVP values were seen to be significantly decreased for the first three hours after surgical intervention. They recovered slightly during the following three hours to remain at an average level of 2 pg / 400 μl urine. The extraction procedure described can be used to determine levels of AVP approaching the limit of detection - either due to large volumes of urine or very low concentrations of AVP. (orig./MG) [de

  13. Solid residues

    International Nuclear Information System (INIS)

    Mulder, E.; Duin, P.J. van; Grootenboer, G.J.

    1995-01-01

    A summary is presented of the many investigations that have been done on solid residues of atmospheric fluid bed combustion (AFBC). These residues are bed ash, cyclone ash and bag filter ash. Physical and chemical properties are discussed and then the various uses of residues (in fillers, bricks, gravel, and for recovery of aluminium) are summarised. Toxicological properties of fly ash and stack ash are discussed as are risks of pneumoconiosis for workers handling fly ash, and contamination of water by ashes. On the basis of present information it is concluded that risks to public health from exposure to emissions of coal fly ash from AFBC appear small or negligible as are health risk to workers in the coal fly ash processing industry. 35 refs., 5 figs., 12 tabs

  14. Monitoring human papillomavirus prevalence in urine samples: a review

    Directory of Open Access Journals (Sweden)

    Enerly E

    2013-03-01

    Full Text Available Espen Enerly, Cecilia Olofsson, Mari NygårdDepartment of Research, Cancer Registry of Norway, Oslo, NorwayAbstract: Human papillomavirus (HPV is the main cause of cervical cancer, and many countries now offer vaccination against HPV to girls by way of government-funded national immunization programs. Monitoring HPV prevalence in adolescents could offer a near-term biological measure of vaccine impact, and urine sampling may be an attractive large-scale method that could be used for this purpose. Our objective was to provide an overview of the literature on HPV DNA detection in urine samples, with an emphasis on adolescents. We searched the PubMed database using the terms “HPV” and “urine” and identified 21 female and 14 male study populations in which HPV prevalence in urine samples was reported, four of which included only asymptomatic female adolescents. We provide herein an overview of the recruitment setting, age, urine sampling procedure, lesion type, HPV assay, and HPV prevalence in urine samples and other urogenital samples for the studies included in this review. In female study populations, concordance for any HPV type and type-specific concordance in paired urine and cervical samples are provided in addition to sensitivity and specificity. We concluded that few studies on HPV prevalence in urine samples have been performed in asymptomatic female adolescent populations but that urine samples may be a useful alternative to cervical samples to monitor changes in HPV prevalence in females in the post-HPV vaccination era. However, care should be taken when extrapolating HPV findings from urine samples to the cervix. In males, urine samples do not seem to be optimal for monitoring HPV prevalence due to a low human genomic DNA content and HPV DNA detection rate compared to other urogenital sites. In each situation the costs and benefits of HPV DNA detection in urine compared to alternative monitoring options should be carefully

  15. RBscore&NBench: a high-level web server for nucleic acid binding residues prediction with a large-scale benchmarking database.

    Science.gov (United States)

    Miao, Zhichao; Westhof, Eric

    2016-07-08

    RBscore&NBench combines a web server, RBscore and a database, NBench. RBscore predicts RNA-/DNA-binding residues in proteins and visualizes the prediction scores and features on protein structures. The scoring scheme of RBscore directly links feature values to nucleic acid binding probabilities and illustrates the nucleic acid binding energy funnel on the protein surface. To avoid dataset, binding site definition and assessment metric biases, we compared RBscore with 18 web servers and 3 stand-alone programs on 41 datasets, which demonstrated the high and stable accuracy of RBscore. A comprehensive comparison led us to develop a benchmark database named NBench. The web server is available on: http://ahsoka.u-strasbg.fr/rbscorenbench/. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  16. An encodable lanthanide binding tag with reduced size and flexibility for measuring residual dipolar couplings and pseudocontact shifts in large proteins

    Energy Technology Data Exchange (ETDEWEB)

    Barb, Adam W., E-mail: abarb@iastate.edu; Subedi, Ganesh P. [Iowa State University, Roy J. Carver Department of Biochemistry, Biophysics and Molecular Biology (United States)

    2016-01-15

    Metal ions serve important roles in structural biology applications from long-range perturbations seen in magnetic resonance experiments to electron-dense signatures in X-ray crystallography data; however, the metal ion must be secured in a molecular framework to achieve the maximum benefit. Polypeptide-based lanthanide-binding tags (LBTs) represent one option that can be directly encoded within a recombinant protein expression construct. However, LBTs often exhibit significant mobility relative to the target molecule. Here we report the characterization of improved LBTs sequences for insertion into a protein loop. These LBTs were inserted to connect two parallel alpha helices of an immunoglobulin G (IgG)-binding Z domain platform. Variants A and B bound Tb{sup 3+} with high affinity (0.70 and 0.13 μM, respectively) and displayed restricted LBT motion. Compared to the parent construct, the metal-bound A experienced a 2.5-fold reduction in tag motion as measured by magnetic field-induced residual dipolar couplings and was further studied in a 72.2 kDa complex with the human IgG1 fragment crystallizable (IgG1 Fc) glycoprotein. The appearance of both pseudo-contact shifts (−0.221 to 0.081 ppm) and residual dipolar couplings (−7.6 to 14.3 Hz) of IgG1 Fc resonances in the IgG1 Fc:(variant A:Tb{sup 3+}){sub 2} complex indicated structural restriction of the LBT with respect to the Fc. These studies highlight the applicability of improved LBT sequences with reduced mobility to probe the structure of macromolecular systems.

  17. A Large-scale Finite Element Model on Micromechanical Damage and Failure of Carbon Fiber/Epoxy Composites Including Thermal Residual Stress

    Science.gov (United States)

    Liu, P. F.; Li, X. K.

    2018-06-01

    The purpose of this paper is to study micromechanical progressive failure properties of carbon fiber/epoxy composites with thermal residual stress by finite element analysis (FEA). Composite microstructures with hexagonal fiber distribution are used for the representative volume element (RVE), where an initial fiber breakage is assumed. Fiber breakage with random fiber strength is predicted using Monte Carlo simulation, progressive matrix damage is predicted by proposing a continuum damage mechanics model and interface failure is simulated using Xu and Needleman's cohesive model. Temperature dependent thermal expansion coefficients for epoxy matrix are used. FEA by developing numerical codes using ANSYS finite element software is divided into two steps: 1. Thermal residual stresses due to mismatch between fiber and matrix are calculated; 2. Longitudinal tensile load is further exerted on the RVE to perform progressive failure analysis of carbon fiber/epoxy composites. Numerical convergence is solved by introducing the viscous damping effect properly. The extended Mori-Tanaka method that considers interface debonding is used to get homogenized mechanical responses of composites. Three main results by FEA are obtained: 1. the real-time matrix cracking, fiber breakage and interface debonding with increasing tensile strain is simulated. 2. the stress concentration coefficients on neighbouring fibers near the initial broken fiber and the axial fiber stress distribution along the broken fiber are predicted, compared with the results using the global and local load-sharing models based on the shear-lag theory. 3. the tensile strength of composite by FEA is compared with those by the shear-lag theory and experiments. Finally, the tensile stress-strain curve of composites by FEA is applied to the progressive failure analysis of composite pressure vessel.

  18. An encodable lanthanide binding tag with reduced size and flexibility for measuring residual dipolar couplings and pseudocontact shifts in large proteins

    International Nuclear Information System (INIS)

    Barb, Adam W.; Subedi, Ganesh P.

    2016-01-01

    Metal ions serve important roles in structural biology applications from long-range perturbations seen in magnetic resonance experiments to electron-dense signatures in X-ray crystallography data; however, the metal ion must be secured in a molecular framework to achieve the maximum benefit. Polypeptide-based lanthanide-binding tags (LBTs) represent one option that can be directly encoded within a recombinant protein expression construct. However, LBTs often exhibit significant mobility relative to the target molecule. Here we report the characterization of improved LBTs sequences for insertion into a protein loop. These LBTs were inserted to connect two parallel alpha helices of an immunoglobulin G (IgG)-binding Z domain platform. Variants A and B bound Tb 3+ with high affinity (0.70 and 0.13 μM, respectively) and displayed restricted LBT motion. Compared to the parent construct, the metal-bound A experienced a 2.5-fold reduction in tag motion as measured by magnetic field-induced residual dipolar couplings and was further studied in a 72.2 kDa complex with the human IgG1 fragment crystallizable (IgG1 Fc) glycoprotein. The appearance of both pseudo-contact shifts (−0.221 to 0.081 ppm) and residual dipolar couplings (−7.6 to 14.3 Hz) of IgG1 Fc resonances in the IgG1 Fc:(variant A:Tb 3+ ) 2 complex indicated structural restriction of the LBT with respect to the Fc. These studies highlight the applicability of improved LBT sequences with reduced mobility to probe the structure of macromolecular systems

  19. Urine Sodium in 3 Consecutive Days Urine collected from ...

    African Journals Online (AJOL)

    Epidemiological and experimental studies have shown that salt sensitivity, which is a heritable trait, is a hallmark to hypertension in blacks. Previous studies on twenty-four hour urinary sodium were either incomplete or yielded contradictory results possibly from incomplete urine collection. This study attempted complete ...

  20. Overall and class-specific scores of pesticide residues from fruits and vegetables as a tool to rank intake of pesticide residues in United States: A validation study.

    Science.gov (United States)

    Hu, Yang; Chiu, Yu-Han; Hauser, Russ; Chavarro, Jorge; Sun, Qi

    2016-01-01

    Pesticide residues in fruits and vegetables are among the primary sources of pesticide exposure through diet, but the lack of adequate measurements hinder the research on health effects of pesticide residues. Pesticide Residue Burden Score (PRBS) for estimating overall dietary pesticide intake, organochlorine pesticide score (OC-PRBS) and organophosphate pesticide score (OP-PRBS) for estimating organochlorine and organophosphate pesticides-specific intake, respectively, were derived using U.S. Department of Agriculture Pesticide Data Program data and National Health and Nutrition Examination Survey (NHANES) food frequency questionnaire data. We evaluated the performance of these scores by validating the scores against pesticide metabolites measured in urine or serum among 3,679 participants in NHANES using generalized linear regression. The PRBS was positively associated with a score summarizing the ranks of all pesticide metabolites in a linear fashion (p for linear trend trend trend 0.07) for the OC-PRBS. The PRBS and OP-PRBS had similar performance when they were derived from fruits and vegetables with high vs. low pesticide residues, respectively (p for trend trend 0.07) than from less contaminated Fruits and vegetables (p for trend 0.63), although neither of the associations achieved statistical significance. The PRBS and the class-specific scores for two major types of pesticides were significantly associated with pesticide biomarkers. These scores can reasonably rank study participants by their pesticide residue exposures from fruits and vegetables in large-scale environmental epidemiological studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. CORRELATION OF SPOT URINE ALBUMIN AND 12-HOUR URINE PROTEIN WITH 24-HOUR URINE PROTEIN IN PRE-ECLAMPSIA

    Directory of Open Access Journals (Sweden)

    S. Vinayachandran

    2017-11-01

    Full Text Available BACKGROUND Pre-eclampsia is defined as the development of new-onset hypertension in the second half of pregnancy often accompanied by new-onset proteinuria with other signs and symptoms. Proteinuria is defined by the excretion of 300 mg or more of protein in a 24-hour urine collection. To avoid time consumed in collection of 24-hour urine specimens, efforts have been made to develop faster methods to determine concentration of urine protein. Preliminary studies have suggested that 12-hour urine protein collection maybe adequate for evaluation of pre-eclampsia with advantage of early diagnosis and treatment of pre-eclampsia as well as potential for early hospital discharge and increased compliance with specimen collection. The aim of the study is to evaluate and correlate spot urine albumin and 12-hour urine protein with 24-hour urine protein in pre-eclampsia. MATERIALS AND METHODS A diagnostic evaluation study- a 24-hour urine protein, 12-hour urine protein and spot urine albumin results are analysed. Correlation of 12-hour urine protein and spot urine albumin with 24-hour urine protein is analysed using SPSS software. The strength of correlation was measured by Pearson’s correlation coefficient (r. Student’s t-test and Chi-square tests were used to compare patients with and without 24-hour urine protein ≥300 mg. Probability value of 165 mg with 24-hour urine protein ≥300 mg suggest that this test has role in the evaluation of women with suspected pre-eclampsia and could be substituted for 24-hour urine protein as a simple, faster and cheaper method.

  2. Residual basins

    International Nuclear Information System (INIS)

    D'Elboux, C.V.; Paiva, I.B.

    1980-01-01

    Exploration for uranium carried out over a major portion of the Rio Grande do Sul Shield has revealed a number of small residual basins developed along glacially eroded channels of pre-Permian age. Mineralization of uranium occurs in two distinct sedimentary units. The lower unit consists of rhythmites overlain by a sequence of black shales, siltstones and coal seams, while the upper one is dominated by sandstones of probable fluvial origin. (Author) [pt

  3. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A novel urine pretreatment that will prevent biological growth or chemical instabilities in urine without using hazardous chemicals is proposed. Untreated urine...

  4. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer

    NARCIS (Netherlands)

    Broeren, M.A.C.; Bahceci, C.; Vader, H.; Arents, N.L.A.

    2011-01-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated

  5. First Industrial Tests of a Drum Monitor Matrix Correction for the Fissile Mass Measurement in Large Volume Historic Metallic Residues with the Differential Die-away Technique

    Energy Technology Data Exchange (ETDEWEB)

    Antoni, R.; Passard, C.; Perot, B.; Batifol, M.; Vandamme, J.C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 St Paul-lez-Durance, (France); Grassi, G. [AREVA NC, 1 place Jean-Millier, 92084 Paris-La-Defense cedex (France)

    2015-07-01

    The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique (DDT. In the next years, old hulls and nozzles mixed with Ion-Exchange Resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, the Nuclear Measurement Laboratory (NML) of CEA Cadarache has studied a matrix effect correction method, based on a drum monitor ({sup 3}He proportional counter inside the measurement cavity). A previous study performed with the NML R and D measurement cell PROMETHEE 6 has shown the feasibility of method, and the capability of MCNP simulations to correctly reproduce experimental data and to assess the performances of the proposed correction. A next step of the study has focused on the performance assessment of the method on the industrial station using numerical simulation. A correlation between the prompt calibration coefficient of the {sup 239}Pu signal and the drum monitor signal was established using the MCNPX computer code and a fractional factorial experimental design composed of matrix parameters representative of the variation range of historical waste. Calculations have showed that the method allows the assay of the fissile mass with an uncertainty within a factor of 2, while the matrix effect without correction ranges on 2 decades. In this paper, we present and discuss the first experimental tests on the industrial ACC measurement system. A calculation vs. experiment benchmark has been achieved by performing dedicated calibration measurement with a representative drum and {sup 235}U samples. The preliminary comparison between calculation and experiment shows a satisfactory agreement for the drum monitor. The final objective of this work is to confirm the reliability of the

  6. First Industrial Tests of a Drum Monitor Matrix Correction for the Fissile Mass Measurement in Large Volume Historic Metallic Residues with the Differential Die-away Technique

    International Nuclear Information System (INIS)

    Antoni, R.; Passard, C.; Perot, B.; Batifol, M.; Vandamme, J.C.; Grassi, G.

    2015-01-01

    The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique (DDT. In the next years, old hulls and nozzles mixed with Ion-Exchange Resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, the Nuclear Measurement Laboratory (NML) of CEA Cadarache has studied a matrix effect correction method, based on a drum monitor ( 3 He proportional counter inside the measurement cavity). A previous study performed with the NML R and D measurement cell PROMETHEE 6 has shown the feasibility of method, and the capability of MCNP simulations to correctly reproduce experimental data and to assess the performances of the proposed correction. A next step of the study has focused on the performance assessment of the method on the industrial station using numerical simulation. A correlation between the prompt calibration coefficient of the 239 Pu signal and the drum monitor signal was established using the MCNPX computer code and a fractional factorial experimental design composed of matrix parameters representative of the variation range of historical waste. Calculations have showed that the method allows the assay of the fissile mass with an uncertainty within a factor of 2, while the matrix effect without correction ranges on 2 decades. In this paper, we present and discuss the first experimental tests on the industrial ACC measurement system. A calculation vs. experiment benchmark has been achieved by performing dedicated calibration measurement with a representative drum and 235 U samples. The preliminary comparison between calculation and experiment shows a satisfactory agreement for the drum monitor. The final objective of this work is to confirm the reliability of the modeling approach

  7. Biologically Pre-Treated Habitation Waste Water as a Sustainable Green Urine Pre-Treat Solution

    Science.gov (United States)

    Jackson, W. Andrew; Thompson, Bret; Sevanthi, Ritesh; Morse, Audra; Meyer, Caitlin; Callahan, Michael

    2017-01-01

    The ability to recover water from urine and flush water is a critical process to allow long term sustainable human habitation in space or bases on the moon or mars. Organic N present as urea or similar compounds can hydrolyze producing free ammonia. This reaction results in an increase in the pH converting ammonium to ammonia which is volatile and not removed by distillation. The increase in pH will also cause precipitation reactions to occur. In order to prevent this, urine on ISS is combined with a pretreat solution. While use of a pretreatment solution has been successful, there are numerous draw backs including: storage and use of highly hazardous solutions, limitations on water recovery (less than 85%), and production of brine with pore dewatering characteristics. We evaluated the use of biologically treated habitation wastewaters (ISS and early planetary base) to replace the current pretreat solution. We evaluated both amended and un-amended bioreactor effluent. For the amended effluent, we evaluated "green" pretreat chemicals including citric acid and citric acid amended with benzoic acid. We used a mock urine/air separator modeled after the urine collection assembly on ISS. The urine/air separator was challenged continually for >6 months. Depending on the test point, the separator was challenged daily with donated urine and flushed with amended or un-amended reactor effluent. We monitored the pH of the urine, flush solution and residual pH in the urine/air separator after each urine event. We also evaluated solids production and biological growth. Our results support the use of both un-amended and amended bioreactor effluent to maintain the operability of the urine /air separator. The ability to use bioreactor effluent could decrease consumable cost, reduce hazards associated with current pre-treat chemicals, allow other membrane based desalination processes to be utilized, and improve brine characteristics.

  8. Monitoring and comparison of tritium content in urine

    International Nuclear Information System (INIS)

    Su Feng; Hua Wei; Zheng Chuancheng; Wang Xu; Wen Wanxin

    2009-01-01

    Objective: To ensure the health of staff engaged in tritium, the purpose of experiment is to find out a fast, convenient and reliable sample preparation and measurement methods for such routine monitoring. Methods: We use the conventional distillation decolorization and non-decoloration quenching correction methods dealing with urine sample, and then carried out the urine sample liquid scintillation measurements, statistical analysis between the two measurements. Results: By using above two different methods of sample pretreatment, the results that we measure tritium in urine sample are not obviously different in comparison. Conclusion: The above two different methods can be used for nuclear facilities staff and staff related to conventional tritium detection. However, non-decoloration quenching correction method is simpler and less in time and manpower than the conventional distillation method in operation. It is suitable for a large number of samples prepared, measured, and analyzed in a short period of time. (authors)

  9. Acute effects of high-dose furosemide on residual renal function in CAPD patients

    NARCIS (Netherlands)

    van Olden, Rudolf W.; Guchelaar, Henk-Jan; Struijk, Dirk G.; Krediet, Raymond T.; Arisz, Lambertus

    2003-01-01

    BACKGROUND: High doses of furosemide can increase urine volume in chronic peritoneal dialysis (CAPD) patients. However, no information is available about effects on urinary solute excretion in relation to residual glomerular filtration rate (GFR), urinary furosemide excretion, and peritoneal solute

  10. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  11. Determination of americium in urine

    International Nuclear Information System (INIS)

    Shvydko, N.S.; Mikhajlova, O.A.; Popov, D.K.

    1988-01-01

    A technique has been developed for the determination of americium 241 in urine by a raiochemical purification of the nuclide from uranium (upon co-precipitation of americium 241 with calcium and lanthanum), plutonium, thorum, and polonium 210 (upon co-precipitation of these radionuclides with zirconium iodate). α-Radioactivity was measured either in a thick layer of the americium 241 precipitate with a nonisotope carrier or in thin-layer preparations after electrolytic precipitation of americium 241 on a cathode

  12. Proton NMR Studies of a Large Protein. pH, Substrate Titrations, and NOESY Experiments with Perdeuterated Yeast Phosphoglycerate Kinase Containing [ 1H]Histidine Residues

    Science.gov (United States)

    Pappu, K. M.; Serpersu, E. H.

    Fully deuterated yeast phosphoglycerate kinase ([ 2H]PGK) was prepared biosynthetically with only histidine side chains of normal ( 1H) isotopic composition. The 1H NMR spectrum of this enzyme([ 1H]His[ 2H]PGK) showed that the histidine side chains are clearly visible as sharp signals. Thus detailed structural studies by 1H NMR became feasible with isotope-hybrid phosphoglycerate kinase which is otherwise too large ( Mr ˜ 46,000) for conventional 1H NMR studies. Proton signals of bound substrates were visible in the 1H NMR spectrum even with a substrate-to-enzyme ratio of less than 1/2 (mol/mol). The 2D NOESY spectrum of enzyme-MgdATP-glycerol 3-phosphate complex showed that, although protein concentration was very high (1.5 m M), no intraprotein cross peaks were observed other than those of intraresidue histidine NOE cross peaks. In addition, intrasubstrate NOEs and intermolecular NOEs between histidine and substrate protons were visible at a 1.5/1 substrate/enzyme (mol/mol) ratio. Paramagnetic effects of a substrate analog, Cr(III)ATP, on some of the histidine side chains indicated that the formation of the ternary enzyme-substrate complex causes large conformational changes in the enzyme.

  13. Determination of penicillin G in heavy sow urine using immunochromatographic assay and microbial inhibition swab tests

    Science.gov (United States)

    Introduction: Penicillin is a commonly used antibiotic in food animals. Unfortunately, violative penicillin residues in animal carcasses are sometimes identified by the USDA Food Safety and Inspection Service. Ante-mortem matrices such as urine could prove valuable for predicting possible violativ...

  14. The performance of fully automated urine analysis results for predicting the need of urine culture test

    Directory of Open Access Journals (Sweden)

    Hatice Yüksel

    2014-06-01

    Full Text Available Objectives: Urinalysis and urine culture are most common tests for diagnosis of urinary tract infections. The aim of our study is to examine the diagnostic performance of urine analysis and the role of urine analysis to determine the requirements for urine culture. Methods: Urine culture and urine analysis results of 362 patients were retrospectively analyzed. Culture results were taken as a reference for chemical and microscopic examination of urine and diagnostic accuracy of the test parameters, that may be a marker for urinary tract infection, and the performance of urine analysis were calculated for predicting the urine culture requirements. Results: A total of 362 urine culture results of patients were evaluated and 67% of them were negative. The results of leukocyte esterase and nitrite in chemical analysis and leukocytes and bacteria in microscopic analysis were normal in 50.4% of culture negative urines. In diagnostic accuracy calculations, leukocyte esterase (86.1% and microscopy leukocytes (88.0% were found with high sensitivity, nitrite (95.4% and bacteria (86.6% were found with high specificity. The area under the curve was calculated as 0.852 in ROC analysis for microscopic examination for leukocytes. Conclusion: Full-automatic urine devices can provide sufficient diagnostic accuracy for urine analysis. The evaluation of urine analysis results in an effective way can predict the necessity for urine culture requests and especially may contribute to a reduction in the work load and cost. J Clin Exp Invest 2014; 5 (2: 286-289

  15. Cyolane residues in milk of lactating goats

    International Nuclear Information System (INIS)

    Zayed, S.M.A.D.; Osman, A.; Fakhr, I.M.I.

    1981-01-01

    Consecutive feeding of lactating goats with 14 C-alkyl labelled cyolane for 5 days at dietary levels 8 and 16 ppm resulted in the appearance of measurable insecticide residues in milk (0.02-0.04 mg/kg). The residue levels were markedly reduced after a withdrawal period of 7 days. Analysis of urine and milk residues showed the presence of similar metabolites in addition to the parent compound. The major part of the residue consisted of mono-, diethyl phosphate and 2 hydrophilic unknown metabolites. The erythrocyte cholinesterase activity was reduced to about 50% after 24 hours whereas the plasma enzyme was only slightly affected. The animals remained symptom-free during the experimental period. (author)

  16. Sharing Residual Liability

    DEFF Research Database (Denmark)

    Carbonara, Emanuela; Guerra, Alice; Parisi, Francesco

    2016-01-01

    Economic models of tort law evaluate the efficiency of liability rules in terms of care and activity levels. A liability regime is optimal when it creates incentives to maximize the value of risky activities net of accident and precaution costs. The allocation of primary and residual liability...... for policy makers and courts in awarding damages in a large number of real-world accident cases....

  17. Functional and molecular characterization of hyposensitive underactive bladder tissue and urine in streptozotocin-induced diabetic rat.

    Directory of Open Access Journals (Sweden)

    Jayabalan Nirmal

    Full Text Available The functional and molecular alterations of nerve growth factor (NGF and Prostaglandin E2 (PGE2 and its receptors were studied in bladder and urine in streptozotocin (STZ-induced diabetic rats.Diabetes mellitus was induced with a single dose of 45 mg/kg STZ Intraperitoneally (i.p in female Sprague-Dawley rats. Continuous cystometrogram were performed on control rats and STZ treated rats at week 4 or 12 under urethane anesthesia. Bladder was then harvested for histology, expression of EP receptors and NGF by western blotting, PGE2 levels by ELISA, and detection of apoptosis by TUNEL staining. In addition, 4-hr urine was collected from all groups for urine levels of PGE2, and NGF assay. DM induced progressive increase of bladder weight, urine production, intercontraction interval (ICI and residual urine in a time dependent fashion. Upregulation of Prostaglandin E receptor (EP1 and EP3 receptors and downregulation of NGF expression, increase in urine NGF and decrease levels of urine PGE2 at week 12 was observed. The decrease in ICI by intravesical instillation of PGE2 was by 51% in control rats and 31.4% in DM group at week 12.DM induced hyposensitive underactive bladder which is characterized by increased inflammatory reaction, apoptosis, urine NGF levels, upregulation of EP1 and EP3 receptors and decreased bladder NGF and urine PGE2. The data suggest that EP3 receptor are potential targets in the treatment of diabetes induced underactive bladder.

  18. Effect of dietary olaquindox on the growth of large yellow croaker ( Pseudosciaena crocea R.) and the distribution of its residues in fish tissues

    Science.gov (United States)

    Li, Huitao; Wang, Weifang; Mai, Kangsen; Ai, Qinghui; Zhang, Chunxiao; Zhang, Lu

    2014-10-01

    Olaquindox (OLA), one of quinoxaline-N, N-dioxides, has been put under ban. However it was used as a medicinal feed additive early; it promotes the growth of livestock and prevents them from dysentery and bacterial enteritis. In this study, we evaluated the effect of dietary OLA on the growth of large yellow croaker ( Pseudosciaena crocea R.) and the histological distribution of OLA and its metabolite 3-methyl-quinoxaline-2-carboxylic acid (MQCA) in fish tissues. Four diets containing 0 (control), 42.5, 89.5 and 277.2 mg kg-1 OLA, respectively, were formulated and tested, 3 cages (1.0 m × 1.0 m × 1.5 m) each diet and 100 juveniles (9.75 ± 0.35 g) each cage. The fish were fed to satiation twice a day at 05:00 am and 17:00 pm for 8 weeks. The survival rate of fish fed the diet containing 42.5 and 89.5 mg kg-1 OLA was significantly higher than that of fish fed the diet containing 0 and 277.2 mg kg-1 OLA ( P diet containing 42.5 and 89.5 mg·kg-1 OLA was significantly higher than that of fish fed the diet without OLA (control) ( Pdiet with 277.2 mg kg-1 OLA. Fish fed the diet with 277.2 mg kg-1 OLA had the highest content of OLA and MQCA in liver (3.44 and 0.39 mg kg-1, respectively), skin (0.46 and 0.09 mg kg-1, respectively) and muscle (0.24 and 0.06 mg kg-1, respectively). In average, fish fed the diet containing OLA had the highest content of OLA and MQCA in liver which was followed by skin and muscle ( P diet containing OLA, thus imposing a potential safety risk to human health.

  19. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  20. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  1. EVALUATION OF DISPOSABLE DIAPERS FOR QUANTATIVE MEASUREMENTS OF PESTICIDE METABOLITES AND CREATININE IN URINE SAMPLES

    Science.gov (United States)

    This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...

  2. Residual nilpotence and residual solubility of groups

    International Nuclear Information System (INIS)

    Mikhailov, R V

    2005-01-01

    The properties of the residual nilpotence and the residual solubility of groups are studied. The main objects under investigation are the class of residually nilpotent groups such that each central extension of these groups is also residually nilpotent and the class of residually soluble groups such that each Abelian extension of these groups is residually soluble. Various examples of groups not belonging to these classes are constructed by homological methods and methods of the theory of modules over group rings. Several applications of the theory under consideration are presented and problems concerning the residual nilpotence of one-relator groups are considered.

  3. Thermal oxidation of biosolids : the green technology has come of age in large cities[Manure, biosolids, and organic industrial/commercial residuals in land applications programs : improving beneficial reuse and protection of water quality

    Energy Technology Data Exchange (ETDEWEB)

    Puchajda, B.; Oleszkiewicz, J. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Civil Engineering

    2007-07-01

    Biosolids management and disposal that is safe and effective by public standards is difficult, particularly for large communities. Land application, landfilling and thermal oxidation with energy recovery (TOER) are the three most popular forms of solids disposal. This paper focused on different aspects of the TOER technology such as energy recovery; air pollution; volume reduction; impact of solids management on waste water treatment plants; process economics; ash residue management; and recycling of nutrients and heavy metals. The thermal oxidation process was described in detail. Societal and environmental impacts were also identified and common factors in mono-incineration, co-combustion and alternative thermal process technologies were presented. The paper also provided examples of successfully operating incineration installations in Europe and North America. It was concluded that the key assets of TOER include volume reduction; decreased liability and product safety; and beneficial use of ash in construction, with future potential for metals and phosphorus recovery. 32 refs., 2 tabs., 12 figs.

  4. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  5. Evaluation of urine mercury level of dentists in Tehran and its influencial factors

    Directory of Open Access Journals (Sweden)

    Tabatabaei M.

    2006-08-01

    triturated amalgam, storage method of residual amalgam, method of storing mercury and office ventilation. Conclusion: Based on the results of this study, the mean urine mercury content of dentists of Tehran was below the international TLV. The use of precapsulated amalgams had significant effect on the urine mercury. Most of the dentists were working in public or semiprivate clinics, so it is concluded that the level of general hygiene and specially mercury hygiene in these centers seems to be acceptable.

  6. Niclosamide residues in milk and organs of lactating goats

    International Nuclear Information System (INIS)

    El Hindi, A.M.; Sidra, M.S.

    1986-01-01

    14 C-Niclosamide was administered to two groups of lactating goats at levels of 2ppm for five consecutive days and 10ppm as a single dose. Residues of the molluscicide in milk, if at all present, did not exceed 0.001 ppm at any time. About 50% of the administered activity was excreted in faeces, while 30% excreted through urine in animals surviving 6 days after withdrawal. The unchanged molluscicide is present only in relatively trace amounts. The highest residues in organs were found in the liver of both groups (0.01-0.04 ppm). From the results it could be concluded that absorbed niclosamide is completely metabolised and rapidly eliminated through urine, leaving little or no residues of the unchanged molluscicide. Little or no residues were detected in lean muscles and milk which are consumed by humans. There is no preferential deposition of the molluscicide or its metabolites in fat

  7. Studies on urine treatment by biological purification using Azolla and UV photocatalytic oxidation

    Science.gov (United States)

    Liu, Xiaofeng; Chen, Min; Bian, Zuliang; Liu, Chung-Chu

    The amount of water consumed in space station operations is very large. In order to reduce the amount of water which must be resupplied from Earth, the space station needs to resolve the problems of water supply. For this reason, the recovery, regeneration and utilization of urine of astronauts are of key importance. Many investigations on this subject have been reported. Our research is based on biological absorption and, purification using UV photocatalytic oxidation techniques to achieve comprehensive treatment for urine. In the treatment apparatus we created, the urine solution is used as part of the nutrient solution for the biological components in our bioregenerative life support system. After being absorbed, the nutrients from the urine were then decomposed, metabolized and purified which creates a favorable condition for the follow-up oxidation treatment by UV photocatalytic oxidation. After these two processes, the treated urine solution reached Chinese national standards for drinking water quality (GB5749-1985).

  8. Diagnostic and Prognostic MicroRNA Biomarkers for Prostate Cancer in Cell-free Urine

    DEFF Research Database (Denmark)

    Fredsøe, Jacob Christian; Rasmussen, Anne Karin; Thomsen, Anni Rønfeldt

    2017-01-01

    Background: Widespread use of prostate-specific antigen (PSA) testing for prostate cancer (PC) detection has led to extensive overdiagnosis and overtreatment. Urine-based microRNA (miRNA) biomarkers could be useful in PC diagnosis and prognosis. Objective: To train and validate urine-based micro......RNA (miRNA) biomarkers that may assist in PC diagnosis and prognosis. Design, setting, and participants: We profiled the expression levels of 92 miRNAs via reverse transcriptase–poymerase chain reaction in cell-free urine samples from 29 patients with benign prostatic hyperplasia (BPH) and 215 patients...... could help in primary diagnosis of PC and guide treatment decisions. Further validation studies are warranted. Patient summary: Using two large patient cohorts, we searched for novel prostate cancer biomarkers in urine. We found two new sets of microRNA biomarkers in urine that could accurately predict...

  9. Green Urine in Traditional Persian Medicine

    Science.gov (United States)

    Kolouri, Sepideh; Daneshfard, Babak; Jaladat, Amir-Mohammad; Tafazoli, Vahid

    2016-01-01

    The color of urine is an important factor in urine examination, which can help physicians differentiate various diseases. Today, it is known that certain dyes, drug intoxications, and diseases can induce green urine discoloration. In the view of traditional Persian medicine, which is based on humoral medicine, green urine discoloration is generally referred to the dominance of coldness in the body. In fact, it is considered to be a result of a special kind of humoral imbalance and fluid depletion or retention in the human body. Persian scholars believed that green urine could be an indicator of intoxication or a predictor of an imminent spasm or convulsion in pediatric patients. Further investigations could result in finding new diagnostic scales of urine color based on the teachings of traditional Persian medicine. PMID:27103627

  10. Urine Bag as a Modern Day Matula

    OpenAIRE

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may gi...

  11. Radioimmunoassay of triiodothyronine in urine

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gembicki, M.; Schneider, E.; Eder, M.

    1977-01-01

    In 21 cases of hypothyroidism, in 39 cases of hyperthyroidism, in 54 healthy subjects, in 23 pregnant women, and in certain internal diseases determinations of triiodothyronine were carried out in urine by radioimmunoassay. Anti-T 3 antibodies were obtained in rabbits and sheep immunized with a complex of bovine albumin with triiodothyronine ester. Labelled triiodothyronine of high specific activity was obtained by iodinating triodothyronine by the chloramine method. Determinations of triiodothyronine were performed in morning urine and the obtained values were calculated for one-hour excretion. In healthy subjects the excretion of T 3 was from 20 to 95 ng/hour, in hyperthyroidism it was significantly raised to from 120 to over 600 ng/hour, while in most cases of hypothyroidism it was decreased. In pregnancy the urinary excretion of T 3 was normal amounting to from 34 to 87 ng/hour, although in most cases the serum T 3 concentration was raised. In cases of anorexia nervosa and in obese starving subjects the excretion of T 3 fell significantly, and similarly low excretion was found in some cases of debilitating diseases and myocardial infarction. (author)

  12. Determination of natural uranium in urine ({sup 233}U); Dosage de l'uranium dans l'urine ({sup 233}U)

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of uranium in urine is described. The residue obtained by mineralization is dissolved in diluted hydrochloric acid. Uranium is separated by fixation on a permutit 50 column, elution with 0,2 M oxalic acid and electrodeposition on nickel. Uranium is then measured by {alpha} counting. It is thus possible to detect less than 1 pico-curie of uranium in the sample. (author) [French] Cet article decrit une technique de dosage de l'uranium dans l'urine. Apres mineralisation, le residu est dissous dans l'acide chlorhydrique dilue. L'uranium est separe par fixation, sur une colonne de permutite 50, elution au moyen d'acide oxalique 0,2 M et depot electrolytique sur nickel. La mesure faite par comptage {alpha} permet de detecter moins de 1 picocurie d'uranium dans l'echantillon. (auteur)

  13. Radiation protection of radioactively contaminated large areas by phytoremediation and subsequent utilization of the contaminated plant residues (PHYTOREST); Massnahmen zur Strahlenschutzvorsorge radioaktiv belasteter Grossflaechen durch Sanierung mittels Phytoremediation und anschliessende Verwertung der belasteten Pflanzenreststoffe (PHYTOREST)

    Energy Technology Data Exchange (ETDEWEB)

    Mirgorodsky, Daniel; Ollivier, Delphine; Merten, Dirk; Bergmann, Hans; Buechel, Georg [Jena Univ. (Germany). Inst. fuer Geowissenschaften; Willscher, Sabine; Wittig, Juliane; Jablonski, Lukasz; Werner, Peter [Technische Univ. Dresden, Pirna (Germany). Inst. fuer Abfallwirtschaft und Altlasten

    2010-12-15

    Much progress has been achieved over the past 20 years in remediating sites contaminated by heavy metal. However, very large contaminated areas have presented major problems to this day because of remediation costs. Phytoremediation is a new, emerging, sustainable technique of remediating areas with low heavy-metal contamination. One advantage of phytoremediation is the comparatively low cost of the process, which may make it usable also on large areas with low levels of contamination. Besides extracting and immobilizing metals, respectively, phytoremediation among other things also contributes to improving soil quality in terms of physics, chemistry, and ecology. Consequently, phytoremediation offers a great potential for the future. Research into phytoremediation of an area contaminated by heavy metals and radionuclides is carried out on a site in a former uranium mining district in Eastern Thuringia jointly by the Friedrich Schiller University, Jena, and the Technical University of Dresden in a project funded by the German Federal Ministry for Education and Research. The project serves to promote the introduction of soft, biocompatible methods of long-term remediation and to develop conceptual solutions to the subsequent utilization of contaminated plant residues. Optimizing area management is in the focus of phytoremediation studies. (orig.)

  14. Sex steroid levels in urine of cattle of different ages: evaluation of abuse control procedures.

    Science.gov (United States)

    Snoj, Tomaz; Dolenc, Jozica; Kobal, Silvestra

    2014-04-01

    Levels of several natural urinary steroids have been determined in the urine of a large number of animals of different cattle categories in the context of steroid abuse in beef production. Bovine animals of different breeds, sex and age included in the Slovene national residue detection plan for steroid abuse were studied. Urine from 120 males and 174 females was analysed. Urinary boldenone, boldione, androstenedione, equiline, medroxyprogesterone, medroxyprogesterone acetate, melengestrol acetate, progesterone, stanozolol, trenbolone, trenbolone acetate, 17α-ethinylestradiol, 17α-methyltestosterone, epitestosterone, 17β-estradiol, testosterone, and nandrolone were determined by LC-MS/MS. Epitestosterone was found in all bulls; while the proportion of animals containing testosterone and androstenedione increased with age. Testosterone was not detected in bulls less than 5 months of age. Epitestosterone levels, however, were not age dependent. The ratio of testosterone to epitestosterone thus increased with age, from 0.13 ± 0.09 at 1-7 months to 0.42 ± 0.10 at 25-38 months. It was significantly (p < 0.01) higher in bulls above 13 months than in younger animals. In contrast to males, no urinary testosterone was found in females, whereas epitestosterone, androstenedione, progesterone and estradiol were present. The proportion of animals of various age groups in which epitestosterone was detected ranged from 68% to 100%, but the differences were not significant. The presence of both estradiol and progesterone in the same sample was not observed in any animal. The results of this study could be helpful in determining physiological urinary steroid levels in order to provide a baseline for the control of steroid abuse in beef production.

  15. Cooperation of phosphates and carboxylates controls calcium oxalate crystallization in ultrafiltered urine.

    Science.gov (United States)

    Grohe, Bernd; Chan, Brian P H; Sørensen, Esben S; Lajoie, Gilles; Goldberg, Harvey A; Hunter, Graeme K

    2011-10-01

    Osteopontin (OPN) is one of a group of proteins found in urine that are believed to limit the formation of kidney stones. In the present study, we investigate the roles of phosphate and carboxylate groups in the OPN-mediated modulation of calcium oxalate (CaOx), the principal mineral phase found in kidney stones. To this end, crystallization was induced by addition of CaOx solution to ultrafiltered human urine containing either human kidney OPN (kOPN; 7 consecutive carboxylates, 8 phosphates) or synthesized peptides corresponding to residues 65-80 (pSHDHMDDDDDDDDDGD; pOPAR) or 220-235 (pSHEpSTEQSDAIDpSAEK; P3) of rat bone OPN. Sequence 65-80 was also synthesized without the phosphate group (OPAR). Effects on calcium oxalate monohydrate (COM) and dihydrate (COD) formation were studied by scanning electron microscopy. We found that controls form large, partly intergrown COM platelets; COD was never observed. Adding any of the polyelectrolytes was sufficient to prevent intergrowth of COM platelets entirely, inhibiting formation of these platelets strongly, and inducing formation of the COD phase. Strongest effects on COM formation were found for pOPAR and OPAR followed by kOPN and then P3, showing that acidity and hydrophilicity are crucial in polyelectrolyte-affected COM crystallization. At higher concentrations, OPAR also inhibited COD formation, while P3, kOPN and, in particular, pOPAR promoted COD, a difference explainable by the variations of carboxylate and phosphate groups present in the molecules. Thus, we conclude that carboxylate groups play a primary role in inhibiting COM formation, but phosphate and carboxylate groups are both important in initiating and promoting COD formation.

  16. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  17. Phenylbutyrate therapy for maple syrup urine disease.

    Science.gov (United States)

    Brunetti-Pierri, Nicola; Lanpher, Brendan; Erez, Ayelet; Ananieva, Elitsa A; Islam, Mohammad; Marini, Juan C; Sun, Qin; Yu, Chunli; Hegde, Madhuri; Li, Jun; Wynn, R Max; Chuang, David T; Hutson, Susan; Lee, Brendan

    2011-02-15

    Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate in urea cycle disorder patients has been associated with a selective reduction in branched-chain amino acids (BCAA) in spite of adequate dietary protein intake. Based on this clinical observation, we investigated the potential of phenylbutyrate treatment to lower BCAA and their corresponding α-keto acids (BCKA) in patients with classic and variant late-onset forms of maple syrup urine disease (MSUD). We also performed in vitro and in vivo experiments to elucidate the mechanism for this effect. We found that BCAA and BCKA are both significantly reduced following phenylbutyrate therapy in control subjects and in patients with late-onset, intermediate MSUD. In vitro treatment with phenylbutyrate of control fibroblasts and lymphoblasts resulted in an increase in the residual enzyme activity, while treatment of MSUD cells resulted in the variable response which did not simply predict the biochemical response in the patients. In vivo phenylbutyrate increases the proportion of active hepatic enzyme and unphosphorylated form over the inactive phosphorylated form of the E1α subunit of the branched-chain α-keto acid dehydrogenase complex (BCKDC). Using recombinant enzymes, we show that phenylbutyrate prevents phosphorylation of E1α by inhibition of the BCKDC kinase to activate BCKDC overall activity, providing a molecular explanation for the effect of phenylbutyrate in a subset of MSUD patients. Phenylbutyrate treatment may be a valuable treatment for reducing the plasma levels of neurotoxic BCAA and their corresponding BCKA in a subset of MSUD patients and studies of its long-term efficacy are indicated.

  18. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español Obtención de un análisis de orina (video) It ...

  19. Odors from evaporation of acidified pig urine

    NARCIS (Netherlands)

    Willers, H.C.; Hobbs, P.J.; Ogink, N.W.M.

    2004-01-01

    In the Dutch Hercules project feces and urine from pigs are collected separately underneath the slatted floor in a pig house and treated in two processes. Feces are composted and urine is concentrated by water evaporation in a packed bed. Exhaust air from the pig house is used for the evaporation in

  20. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test ( ...

  1. The determination of 210Po in urine

    International Nuclear Information System (INIS)

    Bale, W.F.; Helmkamp, R.W.; Hrynyszyn, V.; Contreras, M.A.

    1975-01-01

    To measure 210 Po present in normal human urine a technique was developed in which a 4.5 x 11cm silver foil was shaken at room temperature for 48-hr periods in each of two successive volumes of 1.7 l. of urine acidified to 0.5N with HCl. Alpha rays were counted with an ionization chamber, coupled to a vibrating reed electrometer, and capable of measuring α-ray pulses originating on both sides of the silver foil serving as a central electrode. The background α-count was less than 2/hr. Analyses of human urine spiked with 0.29 to 0.58pCi of 210 Po, together with studies of urine from dogs carrying significant body burdens of 210 Pb, indicated that the average recovery of added 210 Po from 1.7 l. volumes of spiked human urine was 72%. If it is assumed that the same percentage of 210 Po is extracted from non-spiked urine, then the average 210 Po concentration found in 13 analyses of 2 x 1.7 l. samples from 26 different pools of fresh human urine was 0.023pCi/l. Substantial additional 210 Po was generated on short aging of the urine through radioactive decay of excreted 210 Bi. (author)

  2. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español ...

  3. Survey of attitudes and perceptions of urine-diverting toilets and human waste recycling in Hawaii

    International Nuclear Information System (INIS)

    Lamichhane, Krishna M.; Babcock, Roger W.

    2013-01-01

    Urine constitutes only about 1% of domestic sewage but contains 50% or more of the excreted nutrients and chemicals like hormones and pharmaceutical residues. Urine diverting toilet (UDT) systems can be considered a more sustainable alternative to wastewater management because they allow nutrient recycling, reduce water use, and allow source-separation of hormones and chemicals that can harm the environment. An online survey was conducted to determine whether UDTs are acceptable to the general public in Hawaii and if attitudes and perceptions towards it and human waste (HW) recycling vary with age, sex, level of education, religious affiliation, ethnicity, and employment status. The survey was also intended to detect possible drivers and barriers for the UDTs. Variations on variables were tested at 5% significance (p = 0.05) level (Chi-squared test or ANOVA) and considered significantly different if the p-value was less than 0.05. The results were encouraging as more than 60% are willing to pay extra for the UDT, while only 22% knew that such systems existed. No statistically significant difference was found between males and females on all survey questions at the 5% level. However, females had higher willingness to pay (WTP) than males and WTP increased with age and income. The WTP of Caucasians was higher than Asians and differed significantly. Some respondents expressed concern about the legal provisions for recycling of HW. The survey results indicate that with a public education program, it is possible that most people would be willing to adopt UDTs and HW recycling with incurred societal benefits of reduced water and fertilizer use, reduced greenhouse gas emissions, and collection of micropollutants at the source to prevent their entry into waterways. Because of the small sample size (N = 132, 13% response rate) the survey is not representative but may be indicative of the general attitude of Hawaiian people. - Highlights: ► Urine diverting toilets (UDTs

  4. Survey of attitudes and perceptions of urine-diverting toilets and human waste recycling in Hawaii

    Energy Technology Data Exchange (ETDEWEB)

    Lamichhane, Krishna M., E-mail: lamichha@hawaii.edu [University of Hawaii, Department of Civil and Environmental Engineering, 2540 Dole Street, Holmes Hall 283, Honolulu, Hawaii 96822 (United States); Babcock, Roger W., E-mail: rbabcock@hawaii.edu [University of Hawaii, Department of Civil and Environmental Engineering, Holmes Hall 383, Honolulu, Hawaii 96822 (United States)

    2013-01-15

    Urine constitutes only about 1% of domestic sewage but contains 50% or more of the excreted nutrients and chemicals like hormones and pharmaceutical residues. Urine diverting toilet (UDT) systems can be considered a more sustainable alternative to wastewater management because they allow nutrient recycling, reduce water use, and allow source-separation of hormones and chemicals that can harm the environment. An online survey was conducted to determine whether UDTs are acceptable to the general public in Hawaii and if attitudes and perceptions towards it and human waste (HW) recycling vary with age, sex, level of education, religious affiliation, ethnicity, and employment status. The survey was also intended to detect possible drivers and barriers for the UDTs. Variations on variables were tested at 5% significance (p = 0.05) level (Chi-squared test or ANOVA) and considered significantly different if the p-value was less than 0.05. The results were encouraging as more than 60% are willing to pay extra for the UDT, while only 22% knew that such systems existed. No statistically significant difference was found between males and females on all survey questions at the 5% level. However, females had higher willingness to pay (WTP) than males and WTP increased with age and income. The WTP of Caucasians was higher than Asians and differed significantly. Some respondents expressed concern about the legal provisions for recycling of HW. The survey results indicate that with a public education program, it is possible that most people would be willing to adopt UDTs and HW recycling with incurred societal benefits of reduced water and fertilizer use, reduced greenhouse gas emissions, and collection of micropollutants at the source to prevent their entry into waterways. Because of the small sample size (N = 132, 13% response rate) the survey is not representative but may be indicative of the general attitude of Hawaiian people. - Highlights: ► Urine diverting toilets (UDTs

  5. Protein in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/proteininurine.html Protein in Urine To use the sharing features on this page, please enable JavaScript. What is a Protein in Urine Test? A protein in urine test ...

  6. Ethanol Induced Urine Acidification is Related with Early Acetaldehyde Concentration

    Directory of Open Access Journals (Sweden)

    Soon Kil Kwon

    2014-06-01

    Conclusion: In conclusion, urine acidification after ethanol ingestion is related with serum acetaldehyde concentration. Early elevation of acetaldhyde could induce urine acidification, but the urine pH was elevated after a few hours, that might make prolonged acidemia.

  7. High throughput-screening of animal urine samples: It is fast but is it also reliable?

    Science.gov (United States)

    Kaufmann, Anton

    2016-05-01

    Advanced analytical technologies like ultra-high-performance liquid chromatography coupled to high resolution mass spectrometry can be used for veterinary drug screening of animal urine. The technique is sufficiently robust and reliable to detect veterinary drugs in urine samples of animals where the maximum residue limit of these compounds in organs like muscle, kidney, or liver has been exceeded. The limitations and possibilities of the technique are discussed. The most critical point is the variability of the drug concentration ratio between the tissue and urine. Ways to manage the false positive and false negatives are discussed. The capability to confirm findings and the possibility of semi-targeted analysis are also addressed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Urine: Waste product or biologically active tissue?

    Science.gov (United States)

    2018-03-01

    Historically, urine has been viewed primarily as a waste product with little biological role in the overall health of an individual. Increasingly, data suggest that urine plays a role in human health beyond waste excretion. For example, urine might act as an irritant and contribute to symptoms through interaction with-and potential compromise of-the urothelium. To explore the concept that urine may be a vehicle for agents with potential or occult bioactivity and to discuss existing evidence and novel research questions that may yield insight into such a role, the National Institute of Diabetes and Digestive and Kidney Disease invited experts in the fields of comparative evolutionary physiology, basic science, nephrology, urology, pediatrics, metabolomics, and proteomics (among others) to a Urinology Think Tank meeting on February 9, 2015. This report reflects ideas that evolved from this meeting and current literature, including the concept of urine quality, the biological, chemical, and physical characteristics of urine, including the microbiota, cells, exosomes, pH, metabolites, proteins, and specific gravity (among others). Additionally, the manuscript presents speculative, and hopefully testable, ideas about the functional roles of urine constituents in health and disease. Moving forward, there are several questions that need further understanding and pursuit. There were suggestions to consider actively using various animal models and their biological specimens to elaborate on basic mechanistic information regarding human bladder dysfunction. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  9. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S

    2017-12-19

    In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.

  10. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A nonhazardous urine pretreatment system prototype is proposed that will stabilize urine against biological growth or chemical instabilities without using hazardous...

  11. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    Science.gov (United States)

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  12. A comparison of creatinine concentration with {sup 40}K radioactivity in spot urine

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong [Kyung Hee Univ., Yongin (Korea, Republic of)

    2013-05-15

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10{sup 9}γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this

  13. A comparison of creatinine concentration with 40K radioactivity in spot urine

    International Nuclear Information System (INIS)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook; Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong

    2013-01-01

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10 9 γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this study

  14. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  15. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  16. Application of duckweed for human urine treatment in Bioregenerative Life Support System

    Science.gov (United States)

    Manukovsky, Nickolay; Kovalev, Vladimir

    The object of the study was the common duckweed Lemna minor L. Thanks to the ability to assimilate mineral and organic substances, duckweed is used to purify water in sewage lagoons. In addition, duckweed biomass is known to be a potential high-protein feed resource for domestic animals and fish. The aim of the study was to estimate an application of duckweed in a two-stage treatment of human urine in Bioregenerative Life Support System (BLSS). At the first stage, the urine’s organic matter is oxidized by hydrogen peroxide. Diluted solution of oxidized urine is used for cultivation of duckweed. The appointment of duckweed is the assimilation of mineralized substances of urine. Part of the duckweed biomass yield directly or after composting could be embedded in the soil-like substrate as organic fertilizer to compensate the carry-over in consequence of plant growing. The rest duckweed biomass could be used as a feed for animals in BLSS. Then, the residual culture liquid is concentrated and used as a source of dietary salt. It takes 10-15 m2 of duckweed culture per crewmember to treat oxidized urine. The BLSS configuration including two-component subsystem of urine treatment is presented.

  17. Voltammetric Determination of Thiodiglycolic Acid in Urine

    Czech Academy of Sciences Publication Activity Database

    Dlasková, Z.; Navrátil, Tomáš; Heyrovský, Michael; Pelclová, D.; Novotný, Ladislav

    2003-01-01

    Roč. 375, - (2003), s. 164-168 ISSN 1618-2642 Institutional research plan: CEZ:AV0Z4040901 Keywords : urine * thioglycolic acid * voltammetry Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.715, year: 2003

  18. Murine Automated Urine Sampler (MAUS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines planned development for a low-power, low-mass automated urine sample collection and preservation system for small mammals, capable of...

  19. Urine Albumin and Albumin/ Creatinine Ratio

    Science.gov (United States)

    ... it used? The urine albumin test or albumin/creatinine ratio (ACR) is used to screen people with chronic conditions, such as diabetes and high blood pressure ( hypertension ) that put them at an ...

  20. On-Demand Urine Analyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research program will develop a novel surface-enhanced Raman (SER) sensor that will perform real-time chemical analysis of urine. It...

  1. Sample preparation automation for dosing plutonium in urine

    International Nuclear Information System (INIS)

    Jeanmaire, Lucien; Ballada, Jean; Ridelle Berger, Ariane

    1969-06-01

    After having indicated that dosing urinary plutonium by using the Henry technique can be divided into three stages (plutonium concentration by precipitation, passing the solution on an anionic resin column and plutonium elution, and eluate evaporation to obtain a source of which the radioactivity is measured), and recalled that the automation of the second stage has been reported in another document, this document describes the automation of the first stage, i.e. obtaining from urine a residue containing the plutonium, and sufficiently mineralized to be analyzed by means of ion exchanging resins. Two techniques are proposed, leading to slightly different devices. The different operations to be performed are indicated. The different components of the apparatus are described: beakers, hot plate stirrers, reagent circuits, a system for supernatant suction, and a control-command circuit. The operation and use are then described, and results are given

  2. Residues of tritium-labeled morantel in lactating dairy cattle

    International Nuclear Information System (INIS)

    Lynch, M.J.; Mosher, F.R.; Burnett, D.M.; Newby, T.J.

    1987-01-01

    Residues of morantel and its metabolites were monitored in plasma, urine, and milk of five lactating dairy cattle that received an oral dose of [4,4-pyrimidyl- 3 H 2 ]morantel tartrate at 10 mg/kg. Drug-related radioactivity peaked in plasma at 8 h and in milk by the second milking, postdose, and was 170 and 84 ng/mL, respectively. The fraction of total residues in milk convertible to the marker compound, N-methyl-1,3-propanediamine, was 0.38 on the basis of a comparison of the areas under the curves for total and marker residues. Five days after dosing, 3.9% of the total radioactivity in liver was recovered as tritium water. Total drug-related residues in this target tissue averaged 1.15 μg/g. About half of the drug-related residues in liver was unextractable and was classified by bound

  3. Occurrence of riboflavinyl glucoside in rat urine

    International Nuclear Information System (INIS)

    Ohkawa, Hiroshi; Ohishi, Nobuko; Yagi, Kunio

    1983-01-01

    To investigate the metabolism of riboflavin, [2- 14 C]-riboflavin was administered orally to a rat. The urine pooled for 24 h after administration was fractionated by paper and silica gel thin layer chromatographies using various solvent systems. Among the radioactive metabolites, riboflavinyl glucoside was found along with 7-carboxy lumichrome and 8-carboxy lumichrome. The radioactivity of riboflavinyl glucoside comprised about 6 % of the total radioactivity excreted in the urine during 24 h. (author)

  4. Serial-omics characterization of equine urine.

    Directory of Open Access Journals (Sweden)

    Min Yuan

    Full Text Available Horse urine is easily collected and contains molecules readily measurable using mass spectrometry that can be used as biomarkers representative of health, disease or drug tampering. This study aimed at analyzing microliter levels of horse urine to purify, identify and quantify proteins, polar metabolites and non-polar lipids. Urine from a healthy 12 year old quarter horse mare on a diet of grass hay and vitamin/mineral supplements with limited pasture access was collected for serial-omics characterization. The urine was treated with methyl tert-butyl ether (MTBE and methanol to partition into three distinct layers for protein, non-polar lipid and polar metabolite content from a single liquid-liquid extraction and was repeated two times. Each layer was analyzed by high performance liquid chromatography-high resolution tandem mass spectrometry (LC-MS/MS to obtain protein sequence and relative protein levels as well as identify and quantify small polar metabolites and lipids. The results show 46 urine proteins, many related to normal kidney function, structural and circulatory proteins as well as 474 small polar metabolites but only 10 lipid molecules. Metabolites were mostly related to urea cycle and ammonia recycling as well as amino acid related pathways, plant diet specific molecules, etc. The few lipids represented triglycerides and phospholipids. These data show a complete mass spectrometry based-omics characterization of equine urine from a single 333 μL mid-stream urine aliquot. These omics data help serve as a baseline for healthy mare urine composition and the analyses can be used to monitor disease progression, health status, monitor drug use, etc.

  5. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  6. Preventing Precipitation in the ISS Urine Processor

    Science.gov (United States)

    Muirhead, Dean; Carter, Layne; Williamson, Jill; Chambers, Antja

    2017-01-01

    The ISS Urine Processor Assembly (UPA) was initially designed to achieve 85% recovery of water from pretreated urine on ISS. Pretreated urine is comprised of crew urine treated with flush water, an oxidant (chromium trioxide), and an inorganic acid (sulfuric acid) to control microbial growth and inhibit precipitation. Unfortunately, initial operation of the UPA on ISS resulted in the precipitation of calcium sulfate at 85% recovery. This occurred because the calcium concentration in the crew urine was elevated in microgravity due to bone loss. The higher calcium concentration precipitated with sulfate from the pretreatment acid, resulting in a failure of the UPA due to the accumulation of solids in the Distillation Assembly. Since this failure, the UPA has been limited to a reduced recovery of water from urine to prevent calcium sulfate from reaching the solubility limit. NASA personnel have worked to identify a solution that would allow the UPA to return to a nominal recovery rate of 85%. This effort has culminated with the development of a pretreatment based on phosphoric acid instead of sulfuric acid. By eliminating the sulfate associated with the pretreatment, the brine can be concentrated to a much higher concentration before calcium sulfate reach the solubility limit. This paper summarizes the development of this pretreatment and the testing performed to verify its implementation on ISS.

  7. An update on purple urine bag syndrome

    Directory of Open Access Journals (Sweden)

    Hadano Y

    2012-08-01

    Full Text Available Yoshiro Hadano,1 Taro Shimizu,2 Shimon Takada,3 Toshiya Inoue,4 Sumire Sorano51Department of General Internal Medicine and Infectious Diseases, Rakuwakai Otowa Hospital, Yamashina-ku, Kyoto, Japan; 2Rollins School of Public Health, Emory University, Atlanta, GA, USA; 3Department of General Internal Medicine, Osaka City General Hospital, Miyakojima-ku, Osaka, Japan; 4Department of Emergency Medicine, Urasoe General Hospital, Urasoe-city, Okinawa, Japan; 5Kobe University School of Medicine, Kusunokicho, Chuoku, Kobe, JapanAbstract: Purple urine bag syndrome is characterized by the urinary drainage bag turning purple in patients on prolonged urinary catheterization, especially those in the bedridden state. It is associated with bacterial urinary tract infections caused by indigo-producing and indirubin-producing bacteria, usually affects women, and is associated with alkaline urine, constipation, and a high bacterial load in the urine. Almost all patients with purple urine bag syndrome are catheterized due to significant disability, and the urinary pH is 7.0 or more. In general, intensive treatment with antibiotics is not recommended. Purple urine bag syndrome per se almost always appears to be asymptomatic and harmless. However, caution is needed, because some cases have been reported to show progression to severe disease states, so further research into the morbidity and mortality of this infection is warranted.Keywords: purple urine, urinary catheterization, geriatrics, urinary tract infection

  8. Mutagens in urine of carbon electrode workers

    Energy Technology Data Exchange (ETDEWEB)

    Pasquini, R; Monarca, S; Sforzolini, G S; Conti, R; Fagioli, F

    1982-01-01

    Following previous work carried out in an Italian factory producing carbon electrodes and evaluating the occupational mutagenic-carcinogenic hazards, the authors studied the presence of mutagen metabolites in the urine of workers in the same factory who were exposed to petroleum coke and pitch and in the urine of a control group of unexposed workers. The urine samples were concentrated by absorption on XAD-2 columns and were tested using the Salmonella/microsome assay (strain TA98, TA100, TA1535, TA1538) with and without the addition of beta-glucuronidase and metabolizing system. The collection of urine samples was carried out twice, with an interval of 2 months; 'before working time', 'after working time', and also during Sunday. The results showed that urine samples collected 'before' occupational exposure (upon waking) or on Sunday revealed no mutagenic activity in either worker groups and that the urine samples collected after or during occupational exposure revealed high mutagenic activity in the exposed workers, with a statistically significant difference between the mean of the revertants/plate values for exposed and unexposed workers. On the basis of the previous and the present research, the authors suggest that application of the Salmonella/microsome test to work environments could offer useful and suitable tool for evaluating the health hazards due to mutagenic/carcinogenic substances from occupational exposure.

  9. Bioenergy from sisal residues

    Energy Technology Data Exchange (ETDEWEB)

    Jungersen, G. [Dansk Teknologisk Inst. (Denmark); Kivaisi, A.; Rubindamayugi, M. [Univ. of Dar es Salaam (Tanzania, United Republic of)

    1998-05-01

    The main objectives of this report are: To analyse the bioenergy potential of the Tanzanian agro-industries, with special emphasis on the Sisal industry, the largest producer of agro-industrial residues in Tanzania; and to upgrade the human capacity and research potential of the Applied Microbiology Unit at the University of Dar es Salaam, in order to ensure a scientific and technological support for future operation and implementation of biogas facilities and anaerobic water treatment systems. The experimental work on sisal residues contains the following issues: Optimal reactor set-up and performance; Pre-treatment methods for treatment of fibre fraction in order to increase the methane yield; Evaluation of the requirement for nutrient addition; Evaluation of the potential for bioethanol production from sisal bulbs. The processing of sisal leaves into dry fibres (decortication) has traditionally been done by the wet processing method, which consumes considerable quantities of water and produces large quantities of waste water. The Tanzania Sisal Authority (TSA) is now developing a dry decortication method, which consumes less water and produces a waste product with 12-15% TS, which is feasible for treatment in CSTR systems (Continously Stirred Tank Reactors). (EG)

  10. Peptidomics of urine and other biofluids for cancer diagnostics.

    Science.gov (United States)

    Bauça, Josep Miquel; Martínez-Morillo, Eduardo; Diamandis, Eleftherios P

    2014-08-01

    Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers. © 2013 American Association for Clinical Chemistry.

  11. Dubowitz syndrome: common findings and peculiar urine odor

    Directory of Open Access Journals (Sweden)

    Chehade C

    2013-10-01

    Full Text Available Cynthia Chehade,1 Johnny Awwad,2 Nadine Yazbeck,1 Marianne Majdalani,1 Rima Wakim,1 Hala Tfayli,1 Chantal Farra1,31Department of Pediatrics and Adolescent Medicine, American University of Beirut Medical Center, Beirut, Lebanon; 2Department of Obstetrics and Gynecology, American University of Beirut Medical Center, Beirut, Lebanon; 3Department of Pathology and Laboratory Medicine, American University of Beirut Medical Center, Beirut, LebanonBackground: Dubowitz syndrome is a rare, autosomal recessive disorder characterized by intrauterine and postnatal growth retardation, severe microcephaly, psychomotor retardation, hyperactivity, eczema, and characteristic dysmorphic facial features. Although many cases have been reported, the cause of this disease is still unknown.Case: We present here the case of a Lebanese girl with Dubowitz syndrome in whom an unpleasant urine odor was persistently reported since birth.Conclusion: Although Dubowitz syndrome has been largely described in the medical literature, this is the first time that a peculiar urine odor was reported. This case report adds a new and unusual feature to the numerous findings related to this rare polymorphous syndrome.Keywords: Dubowitz syndrome, autosomal recessive, developmental delay, odorous urine

  12. Optimization of solid phase extraction clean up and validation of quantitative determination of corticosteroids in urine by liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens Hinge; Hansen, Lene Gram; Pedersen, Mikael

    2008-01-01

    was to design a procedure that minimised this difference while using a single SPE procedure and a fast HPLC method that enabled sufficient separation of the epimers beta- and dexamethason. To include conjugated corticosteroids in the analysis, the sample was hydrolysed with Helix Pomatia β...... strong anion exchange SPE column. The final method was validated according to EU regulations for determination of residues of veterinarian drugs in products of animal origin. Initial results showed a large difference in ion suppression between samples of porcine and bovine urine. The aim of optimisation......-glucuronidase/aryl sulfatase. For the final method, which included fluocinolone acetonid, triamcinolone acetonid, beclomethasone, flumethasone, dexamethasone, betamethasone, 6α-methylprednisolone, prednisone and prednisolone, a quantification based on spiked samples carried through the entire analytical procedure was used...

  13. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  14. Minimization of zirconium chlorinator residues

    International Nuclear Information System (INIS)

    Green, G.K.; Harbuck, D.D.

    1995-01-01

    Zirconium chlorinator residues contain an array of rare earths, scandium, unreacted coke, and radioactive thorium and radium. Because of the radioactivity, the residues must be disposed in special waste containment facilities. As these sites become more congested, and with stricter environmental regulations, disposal of large volumes of wastes may become more difficult. To reduce the mass of disposed material, the US Bureau of Mines (USBM) developed technology to recover rare earths, thorium and radium, and unreacted coke from these residues. This technology employs an HCl leach to solubilize over 99% of the scandium and thorium, and over 90% of the rare earths. The leach liquor is processed through several solvent extraction stages to selectively recover scandium, thorium, and rare earths. The leach residue is further leached with an organic acid to solubilize radium, thus allowing unreacted coke to be recycled to the chlorinator. The thorium and radium waste products, which comprise only 2.1% of the original residue mass, can then be sent to the radioactive waste facility

  15. Determination of uranium isotopes in urine

    International Nuclear Information System (INIS)

    Lellis, I.R.; Silva, D.V.F.M. Rey; Taddei, M.H.T.

    2017-01-01

    Variable concentrations of uranium occur naturally in waters, plant products and soils. Small amounts of this element are routinely incorporated by man. Occupationally exposed individuals (IOEs) are subject to the incorporation of higher amounts of uranium into their work routines. The effects on human health resulting from the incorporation of uranium in environmental doses are not very well established and are currently recognized as of little relevance. The incorporation resulting from occupational activities, where higher doses can be found, represents a health risk resulting from chemical damages to the kidneys. Considering that uranium is eliminated from the human body through urine and feces, and that the concentration in the urine can be obtained by means of radiochemical analyzes, this can be considered an efficient indirect method to verify the incorporation of this element. In the work the isotopes of 234 U, 235 U and 238 U were analyzed in urine samples of IOEs and the rate of uranium present in them was verified

  16. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  17. Urine alkalization facilitates uric acid excretion

    Science.gov (United States)

    2010-01-01

    Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet) and others composed of less protein but vegetable-fruit rich food materials (alkali diet). Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+) and anions (Cl-,SO42-,PO4-) necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai) were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-]), indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body. PMID:20955624

  18. Urine alkalization facilitates uric acid excretion

    Directory of Open Access Journals (Sweden)

    Seyama Issei

    2010-10-01

    Full Text Available Abstract Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet and others composed of less protein but vegetable-fruit rich food materials (alkali diet. Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+ and anions (Cl-,SO42-,PO4- necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-], indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body.

  19. Rapid determination of 239Pu in urine samples using molecular recognition technology product AnaLigRPu-02 gel

    International Nuclear Information System (INIS)

    Silvia Dulanska; Boris Remenec; Jan Bilohuscin; Miroslav Labaska; Bianka Horvathova; Andrej Matel

    2013-01-01

    This paper describes the use of IBC's AnaLig R Pu-02 molecular recognition technology product to effectively and selectively pre-concentrate, separate and recover plutonium from urine samples. This method uses two-stage column separations consisting of two different commercial products, Eichrom's Pre-filter Material and AnaLig R Pu-02 resin from IBC Advanced Technologies. By eliminating the co-precipitation techniques and the ashing steps to remove residual organics, the analysis time was reduced significantly. The method was successfully tested by adding known activities of reference solutions of 242 Pu and 239 Pu to urine samples. (author)

  20. Sequential analysis of selected actinides in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.

    1980-07-01

    The monitoring of personnel by urinalysis for suspected contamination by actinides necessitated the development and implementation of an analytical scheme that will separate and identify alpha emitting radionuclides of these elements. The present work deals with Pu, Am, and Th. These elements are separated from an ashed urine sample by means of coprecipitation and ion exchange techniques. The final analysis is carried out by electroplating the actinides and counting in a α-spectrometer. Mean recoveries of these elements from urine are: Pu 64%, Am 74% and Th 69%. (auth)

  1. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  2. Potentiometric determination of iodides in urine

    International Nuclear Information System (INIS)

    Gikolaev, B.A.; Primakova, L.N.; Rakhman'ko, E.M.

    1996-01-01

    Variants of potentiometric method: determination using a calibrations plot, the Gran method, and the double addition method are considered. The method of double additions of the test solution to the reference one is suggested as the most favorable method of determining iodides in urine under clinical laboratory conditions. Refs. 5, tabs. 2

  3. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / ... Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for educational purposes only. For ...

  4. CHROMagar Orientation Medium Reduces Urine Culture Workload

    Science.gov (United States)

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  5. Urine ethanol concentration and alcohol hangover severity

    NARCIS (Netherlands)

    Brookhuis, Karel; Van De Loo, Aurora; Mackus, M.; Verster, Joris

    Background The aim of this study was to examine the relationship between urine ethanol concentration and alcohol hangover severity. Methods N = 36 healthy social drinkers participated in a naturalistic study, comprising a hangover day and a control day. N = 18 of them have regular hangovers (the

  6. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  7. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  8. Determination of natural thorium in urines

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    A procedure for the quantitative analysis of thorium in urine is described. After precipitation with ammonium hydroxide, dissolution of the precipitate, extraction at pH 4-4.2 with cupferron in chloroformic solution and mineralization, a colorimetric determination of thorium with thorin is performed. It is thus possible to detect about 2 γ of thorium in the sample. (author) [fr

  9. URINE CULTURE CONTAMINATION: A ONE-YEAR ...

    African Journals Online (AJOL)

    boaz

    Background: Urine culture contamination is a significant cause of delay in treatment of patients being investigated for urinary tract infection. ... Lowest contamination rates were in Emergency Paediatric Unit (EPU) and intensive ... The female gender was found to be the most significant predictor of higher contamination rate.

  10. Stability of Synthetic Cathinones in Urine.

    Science.gov (United States)

    Glicksberg, Lindsay; Kerrigan, Sarah

    2018-03-01

    In this report, we evaluate the concentration, pH, temperature and analyte-dependent effects on cathinone stability in preserved human urine. A total of 22 synthetic cathinones were evaluated at 100 ng/mL and 1,000 ng/mL in pH 4 and pH 8 urine over 6 months. Specimens were stored at -20°C, 4°C, 20°C and 32°C. The stability of synthetic cathinones was highly dependent on urine pH and storage temperature. Cathinones were considerably more stable in acidic urine (pH 4) at low temperature. In alkaline urine (pH 8) at 32°C, significant losses (>20%) were observed within hours for the majority of drugs. In contrast, all drugs were stable in frozen and refrigerated urine at pH 4 for the duration of the study. These results highlight the importance of sample storage and the potential for pre-analytical changes in concentration during routine shipping and handling of specimens. Significant structural influence was also observed. Cathinones bearing a tertiary amine (pyrrolidine group) were significantly more stable than their secondary amine counterparts. The methylenedioxy group also exerted a significant stabilizing effect on both the tertiary and secondary amines. In the absence of the methylenedioxy group, no significant differences in stability were observed between the unsubstituted and ring substituted secondary amines. Half-lives at ambient temperature in pH 8 urine ranged from 9 h (3-fluoromethcathinone) to 4.3 months (methylenedioxypyrovalerone and 3,4-methylenedioxy-α-pyrrolidinobutiophenone), demonstrating the importance of analyte dependence, and the dual stabilizing effect of both the pyrollidine and methylenedioxy groups. Biological evidence may be subjected to a variety of environmental conditions prior to, and during transport to the forensic laboratory. These findings demonstrate the inherent instability of certain cathinone species in biological evidence under some conditions. Moreover, this study highlights the need for quantitative drug findings in

  11. Residual gas analysis

    International Nuclear Information System (INIS)

    Berecz, I.

    1982-01-01

    Determination of the residual gas composition in vacuum systems by a special mass spectrometric method was presented. The quadrupole mass spectrometer (QMS) and its application in thin film technology was discussed. Results, partial pressure versus time curves as well as the line spectra of the residual gases in case of the vaporization of a Ti-Pd-Au alloy were demonstrated together with the possible construction schemes of QMS residual gas analysers. (Sz.J.)

  12. Protein-Based Urine Test Predicts Kidney Transplant Outcomes

    Science.gov (United States)

    ... News Releases News Release Thursday, August 22, 2013 Protein-based urine test predicts kidney transplant outcomes NIH- ... supporting development of noninvasive tests. Levels of a protein in the urine of kidney transplant recipients can ...

  13. Epithelial Cells in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/epithelialcellsinurine.html Epithelial Cells in Urine To use the sharing features on ... page, please enable JavaScript. What is an Epithelial Cells in Urine Test? Epithelial cells are a type ...

  14. Determination of tetrahydrozoline in urine and blood using gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Peat, Judy; Garg, Uttam

    2010-01-01

    Tetrahydrozoline, a derivative of imidazoline, is widely used for the symptomatic relief of conjunctival and nasal congestion; however, intentional or unintentional high doses can result in toxicity manifested by hypotension, tachycardia, and CNS depression. The detection of the drug in blood and urine is helpful in the diagnosis and management of a toxic patient. For the analysis, plasma, serum, or urine is added to a tube containing alkaline buffer and organic extraction solvents, and tetrahydrozoline from the sample is extracted into the organic phase by gentle mixing. After centrifugation, the upper organic solvent layer containing the drug is removed and dried under stream of nitrogen at 40 degrees C. The residue is reconstituted in a hexane-ethanol mixture and analyzed using gas-chromatography-mass spectrometry. Quantitation of the drug is done by comparing responses of unknown sample to the responses of the calibrators using selected ion monitoring. Naphazoline is used as an internal standard.

  15. Monitoring of ovarian activity by the radioimmunological determination of estrogen glucuronides, estrone and 17β-estradiol in urine

    International Nuclear Information System (INIS)

    Lehtinen, T.; Kairento, A.-L.; Adlercreutz, H.

    1981-01-01

    The present investigation deals with the study of the excretion of several estrogen conjugates measured with simple RIA-methods for direct assay in diluted urine in a large number of menstrual cycles in order to find the most suitable method for clinical use. For comparison a RIA method for estrone and estradiol in urine was developed and assays were carried out in 15 cycles. (Auth.)

  16. Direct radioimmunoassay for the detection of barbiturates in blood and urine

    International Nuclear Information System (INIS)

    Mason, P.A.; Law, B.; Pocock, K.; Moffat, A.C.

    1982-01-01

    A radioimmunoassay has been developed for the detection of barbiturates in blood and urine without any pre-treatment of the sample. It is based on a radioiodinated derivative of 4-hydroxyphenobarbitone which allows use of relatively simple gamma-counting procedures. The assay can detect therapeutic levels of barbiturates in very small amounts (50 μl) of blood and urine samples. It is cheap, rapid, simple to perform and is broadly specific for the barbiturate class of drugs to the exclusion of related drugs. The assay is, therefore, very well suited to the task of screening large numbers of samples for the presence of barbiturates. (author)

  17. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  18. Controls of nitrous oxide emission after simulated cattle urine deposition

    DEFF Research Database (Denmark)

    Baral, Khagendra Raj; Thomsen, Anton Gårde; Olesen, Jørgen E

    2014-01-01

    Urine deposited during grazing is a significant source of atmospheric nitrous oxide (N2O). The potential for N2O emissions from urine patches is high, and a better understanding of controls is needed. This study investigated soil nitrogen (N) dynamics and N2O emissions from cattle urine...

  19. A population study of urine glycerol concentrations in elite athletes competing in North America.

    Science.gov (United States)

    Kelly, Brian N; Madsen, Myke; Sharpe, Ken; Nair, Vinod; Eichner, Daniel

    2013-01-01

    Glycerol is an endogenous substance that is on the World Anti-Doping Agency's list of prohibited threshold substances due to its potential use as a plasma volume expansion agent. The WADA has set the threshold for urine glycerol, including measurement uncertainty, at 1.3 mg/mL. Glycerol in circulation largely comes from metabolism of triglycerides in order to meet energy requirements and when the renal threshold is eclipsed, glycerol is excreted into urine. In part due to ethnic differences in postprandial triglyceride concentrations, we investigated urine glycerol concentrations in a population of elite athletes competing in North America and compared the results to those of athletes competing in Europe. 959 urine samples from elite athletes competing in North America collected for anti-doping purposes were analyzed for urine glycerol concentrations by a gas chromatography mass-spectrometry method. Samples were divided into groups according to: Timing (in- or out-of-competition), Class (strength, game, or endurance sports) and Gender. 333 (34.7%) samples had undetectable amounts of glycerol (sport classes. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Residual stress concerns in containment analysis

    International Nuclear Information System (INIS)

    Costantini, F.; Kulak, R. F.; Pfeiffer, P. A.

    1997-01-01

    The manufacturing of steel containment vessels starts with the forming of flat plates into curved plates. A steel containment structure is made by welding individual plates together to form the sections that make up the complex shaped vessels. The metal forming and welding process leaves residual stresses in the vessel walls. Generally, the effect of metal forming residual stresses can be reduced or virtually eliminated by thermally stress relieving the vesseL In large containment vessels this may not be practical and thus the residual stresses due to manufacturing may become important. The residual stresses could possibly tiect the response of the vessel to internal pressurization. When the level of residual stresses is significant it will affect the vessel's response, for instance the yielding pressure and possibly the failure pressure. The paper will address the effect of metal forming residual stresses on the response of a generic pressure vessel to internal pressurization. A scoping analysis investigated the effect of residual forming stresses on the response of an internally pressurized vessel. A simple model was developed to gain understanding of the mechanics of the problem. Residual stresses due to the welding process were not considered in this investigation

  1. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    Science.gov (United States)

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery

  2. Urine Metabonomics Reveals Early Biomarkers in Diabetic Cognitive Dysfunction.

    Science.gov (United States)

    Song, Lili; Zhuang, Pengwei; Lin, Mengya; Kang, Mingqin; Liu, Hongyue; Zhang, Yuping; Yang, Zhen; Chen, Yunlong; Zhang, Yanjun

    2017-09-01

    Recently, increasing attention has been paid to diabetic encephalopathy, which is a frequent diabetic complication and affects nearly 30% of diabetics. Because cognitive dysfunction from diabetic encephalopathy might develop into irreversible dementia, early diagnosis and detection of this disease is of great significance for its prevention and treatment. This study is to investigate the early specific metabolites biomarkers in urine prior to the onset of diabetic cognitive dysfunction (DCD) by using metabolomics technology. An ultra-high performance liquid-chromatography-quadrupole time-of-flight-mass spectrometry (UPLC-Q/TOF-MS) platform was used to analyze the urine samples from diabetic mice that were associated with mild cognitive impairment (MCI) and nonassociated with MCI in the stage of diabetes (prior to the onset of DCD). We then screened and validated the early biomarkers using OPLS-DA model and support vector machine (SVM) method. Following multivariate statistical and integration analysis, we found that seven metabolites could be accepted as early biomarkers of DCD, and the SVM results showed that the prediction accuracy is as high as 91.66%. The identities of four biomarkers were determined by mass spectrometry. The identified biomarkers were largely involved in nicotinate and nicotinamide metabolism, glutathione metabolism, tryptophan metabolism, and sphingolipid metabolism. The present study first revealed reliable biomarkers for early diagnosis of DCD. It provides new insight and strategy for the early diagnosis and treatment of DCD.

  3. The Urine Proteome as a Biomarker of Radiation Injury

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Terrorist attacks or nuclear accidents could expose large numbers of people to ionizing radiation, and early biomarkers of radiation injury would be critical for triage, treatment and follow-up of such individuals. However, no such biomarkers have yet been proven to exist. We tested the potential of high throughput proteomics to identify protein biomarkers of radiation injury after total body X-ray irradiation in a rat model. Subtle functional changes in the kidney are suggested by an increased glomerular permeability for macromolecules measured within 24 hours after TBI. Ultrastructural changes in glomerular podocytes include partial loss of the interdigitating organization of foot processes. Analysis of urine by LC-MS/MS and 2D-GE showed significant changes in the urine proteome within 24 hours after TBI. Tissue kallikrein 1-related peptidase, cysteine proteinase inhibitor cystatin C and oxidized histidine were found to be increased while a number of proteinase inhibitors including kallikrein-binding protein and albumin were found to be decreased post-irradiation. Thus, TBI causes immediately detectable changes in renal structure and function and in the urinary protein profile. This suggests that both systemic and renal changes are induced by radiation and it may be possible to identify a set of biomarkers unique to radiation injury. PMID:19746194

  4. Mechanisms of urine concentration and dilution (1961)

    International Nuclear Information System (INIS)

    Morel, F.; Guinnebault, M.

    1961-01-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [fr

  5. Radioimmunoassay of urine oxytocin in man

    International Nuclear Information System (INIS)

    Zebidi, A.; Geelen, G.; Allevard, A.M.; Sempore, B.; Jarsaillon, E.; Meunier, C.; Gharib, C.

    1978-01-01

    A radioimmunoassay (RIA) for oxytocin (OT) in urine is described. 125 I-OT was prepared, and antibodies were raised in rabbits against OT coupled to bovine serumalbumine. This allowed us to set up a RIA for OT which limit of detection is 1.25 pg/tube (0.6 μU). The use of an extraction procedure using CG 50 Amberlite is essential. The recovery after extraction reaches 70.5 %. pH 5 is the optimum pH were urine samples must be stored. The superposition of the elution peak of endogenous OT on that of exogenous hormone is an argument in favour of the validity of such an extraction procedure. Daily urinary excretion of OT reaches 9.58 mU +- 3.48 in 18 healthy young men [fr

  6. Phenylbutyrate therapy for maple syrup urine disease

    OpenAIRE

    Brunetti-Pierri, Nicola; Lanpher, Brendan; Erez, Ayelet; Ananieva, Elitsa A.; Islam, Mohammad; Marini, Juan C.; Sun, Qin; Yu, Chunli; Hegde, Madhuri; Li, Jun; Wynn, R. Max; Chuang, David T.; Hutson, Susan; Lee, Brendan

    2010-01-01

    Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate in urea cycle disorder patients has been associated with a selective reduction in branched-chain amino acids (BCAA) in spite of adequate dietary protein intake. Based on this clinical observation, we investigated the potential of phenylbutyrate treatment to lower BCAA and their corresponding α-keto acids (BCKA) in patients with classic and variant late-onset forms of maple syrup urine disease (MSUD). We also performed in vitr...

  7. Environmental heat stress enhances crystallization in urine

    Science.gov (United States)

    Setyawan, H.; Pratiwi, Q. C.; Sjarifah, I.; Atmojo, T. B.; Khotijah

    2018-03-01

    Over the past several decades, agriculture and plantations have been used as the main livelihood of most of the Karanganyar residents. However, these two sources of living are now replaced by industrial areas that employ thousands of people in that district. The development of this industry triggers multiple environmental impacts, including ecosystem and temperature changes. In consequence, there is an increase in air temperature that can cause a variety of diseases, especially in the workplace. According to the International Labour Organization (ILO) data in 2013, one worker dies every 15 second due to a work accident and 160 workers are suffering from the occupational disease. In Indonesia, the incidence of crystallization in urine is actually still unknown, but it is estimated that there are 170,000 cases annually. A high temperature or called heat stress is one among many factors causing this disease to appear. The workers in the textile industry, especially in the Finishing Department Kusumahadi Co. Ltd that exposed heat stress from the finishing machines and inadequate ventilation. This hot working climate causes the human body to adapt in the form of body cooling mechanism or called sweating This adaptation can cause an increase in sweat production and decrease the production of urine. If it is not followed by consuming the recommended amount of water intake, it can result in the precipitation of body salts that, in a long time, will cause crystallization in urine. The research used the analytic observational designs for a cross-sectional study. There were 34 samples collected from 57 finishing workers. The data were analyzed using Spearman correlation test. The results showed that heat stress (p=0,015) and water intake (p=0,034) has a significant correlation with crystallization in urine.

  8. Determination of uranium in urine by fluorometry

    International Nuclear Information System (INIS)

    Afsar, M.; Aziz, A.; Mubarak, M.A.

    1978-01-01

    The report describes fluorometric determination of traces of uranium in the urine of mine workers and persons handling uranium. After preliminary treatment uranium is extracted by solvent extraction with TBP:MIBK mixtures. An aliquot of the extracted solution is fused with high carbonate flux at 650 0 C in platinum dishes. The fluorescence of fused sample is measured using a fluorometer. Various fusion parameters are discussed. The procedure for the operation and calibration of fluorometer is also described

  9. Comparison of two preparatory techniques for urine cytology.

    Science.gov (United States)

    Dhundee, J; Rigby, H S

    1990-01-01

    Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176

  10. Handling of Solid Residues

    International Nuclear Information System (INIS)

    Medina Bermudez, Clara Ines

    1999-01-01

    The topic of solid residues is specifically of great interest and concern for the authorities, institutions and community that identify in them a true threat against the human health and the atmosphere in the related with the aesthetic deterioration of the urban centers and of the natural landscape; in the proliferation of vectorial transmitters of illnesses and the effect on the biodiversity. Inside the wide spectrum of topics that they keep relationship with the environmental protection, the inadequate handling of solid residues and residues dangerous squatter an important line in the definition of political and practical environmentally sustainable. The industrial development and the population's growth have originated a continuous increase in the production of solid residues; of equal it forms, their composition day after day is more heterogeneous. The base for the good handling includes the appropriate intervention of the different stages of an integral administration of residues, which include the separation in the source, the gathering, the handling, the use, treatment, final disposition and the institutional organization of the administration. The topic of the dangerous residues generates more expectation. These residues understand from those of pathogen type that are generated in the establishments of health that of hospital attention, until those of combustible, inflammable type, explosive, radio-active, volatile, corrosive, reagent or toxic, associated to numerous industrial processes, common in our countries in development

  11. Psychopathology and urine toxicology in methadone patients

    Directory of Open Access Journals (Sweden)

    Gamal Sadek

    2015-06-01

    Full Text Available Several studies reported high rates of psychiatric commorbidity among methadone patients. We examined the relationships of measures of psychopathology to outcomes of screening urine tests for cocaine, opiates, and benzodiazepines in a sample of 56 methadone patients. They also completed the Symptom Check List-90-Revised (SCL-90-R. The highest scales in the SCL-90-R profile of our patients were those indicating somatic discomfort, anger, phobic anxiety, paranoid ideation, and also obsessive-compulsive disorder symptoms (scores above the 39th percentile. The only significant correlations between urine tests and SCL-90-R psychopathology were those involving benzodiazepines: patients with urine tests positive for benzodiazepines had lower social self-confidence (r=0.48, were more obsessive-compulsive (r=0.44, reported a higher level of anger (r=0.41, of phobic tendencies (r=40, of anxiety (r=0.39, and of paranoid tendencies (r=0.38, and also reported more frequent psychotic symptoms (r=0.43.

  12. Urine sample preparation for proteomic analysis.

    Science.gov (United States)

    Olszowy, Pawel; Buszewski, Boguslaw

    2014-10-01

    Sample preparation for both environmental and more importantly biological matrices is a bottleneck of all kinds of analytical processes. In the case of proteomic analysis this element is even more important due to the amount of cross-reactions that should be taken into consideration. The incorporation of new post-translational modifications, protein hydrolysis, or even its degradation is possible as side effects of proteins sample processing. If protocols are evaluated appropriately, then identification of such proteins does not bring difficulties. However, if structural changes are provided without sufficient attention then protein sequence coverage will be reduced or even identification of such proteins could be impossible. This review summarizes obstacles and achievements in protein sample preparation of urine for proteome analysis using different tools for mass spectrometry analysis. The main aim is to present comprehensively the idea of urine application as a valuable matrix. This article is dedicated to sample preparation and application of urine mainly in novel cancer biomarkers discovery. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

    DEFF Research Database (Denmark)

    Artacho-Cordón, F; Arrebola, J P; Nielsen, O

    2017-01-01

    The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained fro...

  14. Short-term emissions of ammonia and carbon dioxide from cattle urine contaminated tropical grassland microcosm.

    Science.gov (United States)

    Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish

    2006-11-01

    The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter

  15. Stability of cannabinoids in urine in three storage temperatures.

    Science.gov (United States)

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  16. Albumin adsorption onto surfaces of urine collection and analysis containers.

    Science.gov (United States)

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  18. Urine Concentration and Pyuria for Identifying UTI in Infants.

    Science.gov (United States)

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  19. Characterization of Hospital Residuals

    International Nuclear Information System (INIS)

    Blanco Meza, A.; Bonilla Jimenez, S.

    1997-01-01

    The main objective of this investigation is the characterization of the solid residuals. A description of the handling of the liquid and gassy waste generated in hospitals is also given, identifying the source where they originate. To achieve the proposed objective the work was divided in three stages: The first one was the planning and the coordination with each hospital center, in this way, to determine the schedule of gathering of the waste can be possible. In the second stage a fieldwork was made; it consisted in gathering the quantitative and qualitative information of the general state of the handling of residuals. In the third and last stage, the information previously obtained was organized to express the results as the production rate per day by bed, generation of solid residuals for sampled services, type of solid residuals and density of the same ones. With the obtained results, approaches are settled down to either determine design parameters for final disposition whether for incineration, trituration, sanitary filler or recycling of some materials, and storage politics of the solid residuals that allow to determine the gathering frequency. The study concludes that it is necessary to improve the conditions of the residuals handling in some aspects, to provide the cleaning personnel of the equipment for gathering disposition and of security, minimum to carry out this work efficiently, and to maintain a control of all the dangerous waste, like sharp or polluted materials. In this way, an appreciable reduction is guaranteed in the impact on the atmosphere. (Author) [es

  20. Determination of radium in urine; Dosage du radium dans l'urine

    Energy Technology Data Exchange (ETDEWEB)

    Fourniguet, H; Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of radium in urine is described. The radium is carried by a barium sulfate precipitate. The precipitate is mixed with zinc sulfide and the activity measured by scintillation counting. It is thus possible to detect an amount of radium less than 1 pico-curie in the sample. (author) [French] Cet article decrit une technique de dosage du radium dans l'urine. Le radium entraine par un precipite de sulfate de baryum est compte par scintillation apres melange du precipite avec du sulfure de zinc. Cette methode permet de deceler moins de 1 picocurie de radium dans l'echantillon. (auteur)

  1. Changes in urine composition after trauma facilitate bacterial growth

    Directory of Open Access Journals (Sweden)

    Aubron Cecile

    2012-11-01

    Full Text Available Abstract Background Critically ill patients including trauma patients are at high risk of urinary tract infection (UTI. The composition of urine in trauma patients may be modified due to inflammation, systemic stress, rhabdomyolysis, life support treatment and/or urinary catheter insertion. Methods Prospective, single-centre, observational study conducted in patients with severe trauma and without a history of UTIs or recent antibiotic treatment. The 24-hour urine samples were collected on the first and the fifth days and the growth of Escherichia coli in urine from patients and healthy volunteers was compared. Biochemical and hormonal modifications in urine that could potentially influence bacterial growth were explored. Results Growth of E. coli in urine from trauma patients was significantly higher on days 1 and 5 than in urine of healthy volunteers. Several significant modifications of urine composition could explain these findings. On days 1 and 5, trauma patients had an increase in glycosuria, in urine iron concentration, and in the concentrations of several amino acids compared to healthy volunteers. On day 1, the urinary osmotic pressure was significantly lower than for healthy volunteers. Conclusion We showed that urine of trauma patients facilitated growth of E. coli when compared to urine from healthy volunteers. This effect was present in the first 24 hours and until at least the fifth day after trauma. This phenomenon may be involved in the pathophysiology of UTIs in trauma patients. Further studies are required to define the exact causes of such modifications.

  2. Kombinasi Calcitriol dan Ethynil Ethyl Estradiol Meningkatkan Ekskresi Kalsium Urin dan Risiko Urolitiasis pada Tikus Ovariektomi

    Directory of Open Access Journals (Sweden)

    Hartiningsih Hartiningsih

    2017-06-01

    Full Text Available The high excretion of calcium (Ca in the urine can trigger the formation of urolith. Estrogen and calcitriol decrease urinary Ca excretion. This study aims to examine the combination of calcitriol and ethinyl ethyl estradiol against Ca urinary excretion and urolithiasis risk of ovariectomized rats. Twentyfive female Wistar rats eight weeks old were divided into five groups: i normal control (NK; ii ovariectomized control (OVK; iii ovariectomized + calcitriol (OVD; iv ovariectomized + ethinyl ethyl estradiol (OVE; and v ovariectomized + combination calcitriol and ethinyl ethyl estradiol (OVDE. Seven weeks post-ovariectomy, each rat was put in an individual metabolic cage for the study of Ca balance. At day 4 to 7 of the study, residual feed, urine, and feces were collected daily for Ca analysis. At day 8, the rats were euthanized, the left kidney were collected for histopathological examination. The results showed that combination of calcitriol and ethinyl ethyl estradiol in OVDE rats caused Ca intake and Ca intestinal absorption significantly higher, and urinary Ca excretion tended to be higher although not significantly different compared to OVK rats. Calcium excretion in OVK rat urine was higher compared to the NK rats. The kidney histopathological changes of OVK rats were not different from the NK rats. Histopathological examination of the OVDE group kidney showed protein deposition in the capsular of Bowman’s capsule and proximal tubules, atrophy of the proximal tubules, and necrosis, respectively. It is concluded that the combination of calcitriol with ethinyl ethyl estradiol in ovariectomized rats increased urinary Ca excretion and increased the risk of urolithiasis. ABSTRAK Tingginya ekskresi kalsium (Ca dalam urin dapat menjadi pemicu terbentuknya urolit. Estrogen dan calcitriol menurunkan ekskresi Ca urin. Penelitian ini dilakukan bertujuan untuk mengkaji kombinasi calcitriol dan ethynil ethyl estradiol terhadap ekskresi Ca dalam urin

  3. TRH radioimmunoassay for unextracted human urine

    International Nuclear Information System (INIS)

    Mitsuma, Terunori; Hirooka, Yoshibumi; Nihei, Noriyuki

    1975-01-01

    The authors developed a TRH radioimmunoassay for unextracted human urine using anti-TRH antibody produced by immunization of rabbits with a TRH-bis-diazotized-bovine serum albumin conjugate. The antibody had no crossreactivity with TRH analogues, amino acids or pituitary hormones, but with L or DL-Aze3-TRH. TRH was radioiodinized by Greenwood-Hunter's method, followed by purification on Sephadex G-10. Inactivation of TRH by serum was well documented. The authors found however that this inactivation of TRH could be prevented by adjusting the pH to 3.0 or by keeping the temperature between 4 0 C and -20 0 C. All assay procedures were performed in 0.01 M phosphate buffer with 0.15 M NaCl (pH 7.5) at 4 0 C. Free and bound forms were separated with a second antibody system. In this system, sensitivity was 0.01 ng/tube, recovery was approximately 100%, intrassay reproducibility was 3.2% and interassay variation was 9.8%. TRH levels in urine measured with this system were undetectable to 9.0 ng/ml in normal subjects, undetectable in hyperthyroid patients or a tertiary hypothyroid patient and 13 to 24 ng/ml in primary hypothyroid patients. Approximately 6 percent of the intravenously administered TRH was excreted into the urine within 12 hours following administration in a normal subject. As a result this assay system is quite attractive for clinical determination as well as research application. (Evans, J.)

  4. Urine drug screening in the medical setting.

    Science.gov (United States)

    Hammett-Stabler, Catherine A; Pesce, Amadeo J; Cannon, Donald J

    2002-01-01

    The term drug screen is a misnomer since it implies screening for all drugs, which is not possible. Current practice is to limit the testing to the examination of serum for several drugs such as ethanol, acetaminophen, salicylate, and of urine for several specific drugs or classes of drugs. In the emergency setting the screen should be performed in less than one hour. Controversies continue to exist regarding the value of urine drug testing in the medical setting. The reasons for these include the drugs involved, the sample, the methods utilized to perform the tests, and the level of understanding of the physician using the data, all of which are closely related to the other. Current automated methods provide rapid results demanded in emergency situations, but are often designed for, or adapted from, workplace testing and are not necessarily optimized for clinical applications. Furthermore, the use of these methods without consideration of the frequency in which the drugs are found in a given area is not cost-effective. The laboratory must understand the limitations of the assays used and provide this information to the physician. Additionally, the laboratory and the physicians using the data must cooperate to determine which drugs are appropriate and necessary to measure for their institution and clinical setting. In doing so it should be remembered that for many drugs, the sample, urine, contains the end product(s) of drug metabolism, not the parent drug. Furthermore, it is necessary to understand the pharmacokinetic parameters of the drug of interest when interpreting data. Finally, while testing for some drugs may not appear cost-effective, the prevention or reduction of morbidity and mortality may offset any laboratory costs. While the literature is replete with studies concerning new methods and a few regarding physician understanding, there are none that we could find that thoroughly, objectively, and fully addressed the issues of utility and cost-effectiveness.

  5. Inventing urine incontinence devices for women.

    Science.gov (United States)

    Pieper, B; Cleland, V; Johnson, D E; O'Reilly, J L

    1989-01-01

    Nurses have long been aware of the devastating effects of urinary incontinence on women. Although women may find diapers, pads and protective clothing valuable protection, there are few options for a continuous wear, external urine incontinence device (EUID). Inventors have attempted to develop an EUID since ancient times; the first United States patent for an EUID was awarded in 1949. The purpose of this paper is to review technological considerations for development of an external urinary incontinence device for women. Patents and products illustrate the considerations.

  6. Urine protein concentration estimation for biomarker discovery

    OpenAIRE

    Mistry, Hiten D.; Bramham, Kate; Weston, Andrew; Ward, Malcolm; Thompson, Andrew; Chappell, Lucy C.

    2013-01-01

    Recent advances have been made in the study of urinary proteomics as a diagnostic tool for renal disease and pre-eclampsia which requires accurate measurement of urinary protein. We compared different protein assays (Bicinchoninic acid (BCA), Lowry and Bradford) against the ‘gold standard’ amino-acid assay in urine from 43 women (8 non-pregnant, 34 pregnant, including 8 with pre-eclampsia. BCA assay was superior to both Lowry and Bradford assays (Bland Altman bias: 0.08) compared to amino-aci...

  7. The radioimmunological determination of vasopressin in urine

    International Nuclear Information System (INIS)

    Horn, M.J. van der.

    1981-01-01

    This thesis describes the development of a radioimmunoassay (RIA) for antidiuretic hormone (ADH) or vasopressin, which can be used for the quantitative measurement of the urinary excretion of the hormone in man during physiological and pathological conditions. The final RIA method, using approximately 5 pg 125 I-AVP diluted (1 : 50,000) antiserum 121 and charcoal-dextran separation of the antibody-bound and free fractions, is found to be specific for vasopressin and closely related substances; the sensitivity is 9 pg. The validity is demonstrated and the results of measurements of vasopressin excretion in urine from 39 normal subjects, including 4 children are presented. (Auth.)

  8. Psychogenic urine retention during doping controls

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Schlegel, Marius M.; Brand, Ralf

    2012-01-01

    relation to recovery, performance, and self-perception of professionalism and athletic excellence. Furthermore, a scale developed especially for the close description and measurement of PURD is presented. A questionnaire was used for measuring paruresis. The results are based on two online and one paper...... and pencil study involving 222 German-speaking athletes from various sports. The results indicate that 60% of these athletes have experienced psychogenic urine retention during doping controls, with only 39% of them showing symptoms of paruresis. PURD impacts athlete recovery and self-perception...

  9. Residual stress characterization of steel TIG welds by neutron diffraction and by residual magnetic stray field mappings

    Science.gov (United States)

    Stegemann, Robert; Cabeza, Sandra; Lyamkin, Viktor; Bruno, Giovanni; Pittner, Andreas; Wimpory, Robert; Boin, Mirko; Kreutzbruck, Marc

    2017-03-01

    The residual stress distribution of tungsten inert gas welded S235JRC+C plates was determined by means of neutron diffraction (ND). Large longitudinal residual stresses with maxima around 600 MPa were found. With these results as reference, the evaluation of residual stress with high spatial resolution GMR (giant magneto resistance) sensors was discussed. The experiments performed indicate a correlation between changes in residual stresses (ND) and the normal component of local residual magnetic stray fields (GMR). Spatial variations in the magnetic field strength perpendicular to the welds are in the order of the magnetic field of the earth.

  10. The Effect of Processing on 14C- Chlofenvinphos Residues in Maize Oil and Bioavailability of its Cake Residues on Rats

    International Nuclear Information System (INIS)

    Mahdy, F.; El-Maghraby, S.

    2008-01-01

    Maize seed obtained from 14 C-chlofenvinphos treated plants contained 0.12 % of the applied dose. The insecticide residues in crude oil, methanol and coke amounted to 10 %, 6 % and 69 %, respectively of original residues inside the seeds.The 14 C activity in the crude oil could be a gradual reduced by the refining processes. The alkali treatment and bleaching steps are more effective steps in the refining processes remove about (63 %). The refined oil contained only about 17 % of the 14 C-residues originally present. The major residues in processed oil contain parent compound, in addition to five metabolites of the insecticide. When rats fed the extracted seeds (cake), the bound residues were found to be considerably bioavailable. After feeding rats for 5 days with the cake, a substantial amount of 14 C-residues was eliminated in the urine (59.5 %), while about 20 % was excreted in the feces. About 15 % of the radioactivity was distribution among various organs

  11. Use of ultrasound in petroleum residue upgradation

    Energy Technology Data Exchange (ETDEWEB)

    Sawarkar, A.N.; Pandit, A.B.; Samant, S.D.; Joshi, J.B. [Mumbai Univ., Mumbai (India). Inst. of Chemical Technology

    2009-06-15

    The importance of bottom-of-the barrel upgrading has increased in the current petroleum refining scenario because of the progressively heavier nature of crude oil. Heavy residues contain large concentrations of metals such as vanadium and nickel which foul catalysts and reduce the potential effect of residue fluidized catalytic cracking. This study showed that the cavitational energy induced by ultrasound be be successfully used to upgrade hydrocarbon mixtures. Conventional processes for the upgrading of residual feedstocks, such as thermal cracking and catalytic cracking, were carried out in the temperature range of 400-520 degrees C. Experiments were performed on 2 vacuum residues, Arabian mix vacuum residue (AMVR) and Bombay high vacuum residue (BHVR) and 1 Haldia asphalt (HA). These were subjected to acoustic cavitation for different reaction times from 15 to 120 minutes at ambient temperature and pressure. Two acoustic cavitation devices were compared, namely the ultrasonic bath and ultrasonic horn. In particular, this study compared the ability of these 2 devices to upgrade the petroleum residues to lighter, more value-added products. Different surfactants were used to examine the effect of ultrasound on upgrading the residue when emulsified in water. In order to better understand the reaction mechanism, a kinetic model was developed based on the constituents of the residue. The ultrasonic horn was found to be more effective in bringing about the upgrading than ultrasonic bath. The study also showed that the acoustic cavitation of the aqueous emulsified hydrocarbon mixture could reduce the asphaltenes content to a greater extent than the acoustic cavitation of non-emulsified hydrocarbon mixture. 20 refs., 11 tabs., 17 figs.

  12. Management of NORM Residues

    International Nuclear Information System (INIS)

    2013-06-01

    The IAEA attaches great importance to the dissemination of information that can assist Member States in the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support the nuclear fuel cycle and nuclear applications, and that address the legacy of past practices and accidents. However, radioactive residues are found not only in nuclear fuel cycle activities, but also in a range of other industrial activities, including: - Mining and milling of metalliferous and non-metallic ores; - Production of non-nuclear fuels, including coal, oil and gas; - Extraction and purification of water (e.g. in the generation of geothermal energy, as drinking and industrial process water; in paper and pulp manufacturing processes); - Production of industrial minerals, including phosphate, clay and building materials; - Use of radionuclides, such as thorium, for properties other than their radioactivity. Naturally occurring radioactive material (NORM) may lead to exposures at some stage of these processes and in the use or reuse of products, residues or wastes. Several IAEA publications address NORM issues with a special focus on some of the more relevant industrial operations. This publication attempts to provide guidance on managing residues arising from different NORM type industries, and on pertinent residue management strategies and technologies, to help Member States gain perspectives on the management of NORM residues

  13. Spot urine sodium measurements do not accurately estimate dietary sodium intake in chronic kidney disease12

    Science.gov (United States)

    Dougher, Carly E; Rifkin, Dena E; Anderson, Cheryl AM; Smits, Gerard; Persky, Martha S; Block, Geoffrey A; Ix, Joachim H

    2016-01-01

    Background: Sodium intake influences blood pressure and proteinuria, yet the impact on long-term outcomes is uncertain in chronic kidney disease (CKD). Accurate assessment is essential for clinical and public policy recommendations, but few large-scale studies use 24-h urine collections. Recent studies that used spot urine sodium and associated estimating equations suggest that they may provide a suitable alternative, but their accuracy in patients with CKD is unknown. Objective: We compared the accuracy of 4 equations [the Nerbass, INTERSALT (International Cooperative Study on Salt, Other Factors, and Blood Pressure), Tanaka, and Kawasaki equations] that use spot urine sodium to estimate 24-h sodium excretion in patients with moderate to advanced CKD. Design: We evaluated the accuracy of spot urine sodium to predict mean 24-h urine sodium excretion over 9 mo in 129 participants with stage 3–4 CKD. Spot morning urine sodium was used in 4 estimating equations. Bias, precision, and accuracy were assessed and compared across each equation. Results: The mean age of the participants was 67 y, 52% were female, and the mean estimated glomerular filtration rate was 31 ± 9 mL · min–1 · 1.73 m–2. The mean ± SD number of 24-h urine collections was 3.5 ± 0.8/participant, and the mean 24-h sodium excretion was 168.2 ± 67.5 mmol/d. Although the Tanaka equation demonstrated the least bias (mean: −8.2 mmol/d), all 4 equations had poor precision and accuracy. The INTERSALT equation demonstrated the highest accuracy but derived an estimate only within 30% of mean measured sodium excretion in only 57% of observations. Bland-Altman plots revealed systematic bias with the Nerbass, INTERSALT, and Tanaka equations, underestimating sodium excretion when intake was high. Conclusion: These findings do not support the use of spot urine specimens to estimate dietary sodium intake in patients with CKD and research studies enriched with patients with CKD. The parent data for this

  14. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Determination of iodine in human milk and urine | Ayodele | Ife ...

    African Journals Online (AJOL)

    Physiological concentrations of iodine were determined in milk and urine. Recovery studies are reported along with results for the analysis of milk and urine samples. Iodine contents ranged from 10 - 110 (mean 52.88 ± 22.60mg/l) and 10 - 90 (mean 27.64 ±16.70) g/l in milk and urine respectively. A significant difference is ...

  16. Bisphenol A levels in human urine.

    Science.gov (United States)

    Matsumoto, Akiko; Kunugita, Naoki; Kitagawa, Kyoko; Isse, Toyohi; Oyama, Tsunehiro; Foureman, Gary L; Morita, Masatoshi; Kawamoto, Toshihiro

    2003-01-01

    The estrogenic effects of bisphenol A (BPA) have been reported in human cells (E-screen assays) and in (italic)in vivo(/italic) studies of rodents, although the latter reports remain controversial, as do the exposure levels and adverse health effects of BPA in humans. In this study we report on an analytical high-performance liquid chromatography/fluorescence method for BPA and its conjugate in human urine and on the application of this method in two student cohorts. Urine, along with information on smoking, alcohol intake, and coffee/tea consumption, was collected in two different years from two different groups of university students, 50 in 1992 and 56 in 1999. Overall, the urinary BPA levels in the students in 1992 were significantly higher than were those in 1999. The BPA levels were also positively correlated with coffee and tea consumption in the 1992 cohort but not in the 1999 cohort. We speculate that recent changes made in Japan regarding the interior coating of cans used to package these beverages may partly explain these findings. PMID:12515686

  17. Urine Exosomes: An Emerging Trove of Biomarkers.

    Science.gov (United States)

    Street, J M; Koritzinsky, E H; Glispie, D M; Star, R A; Yuen, P S T

    Exosomes are released by most cells and can be isolated from all biofluids including urine. Exosomes are small vesicles formed as part of the endosomal pathway that contain cellular material surrounded by a lipid bilayer that can be traced to the plasma membrane. Exosomes are potentially a more targeted source of material for biomarker discovery than unfractionated urine, and provide diagnostic and pathophysiological information without an invasive tissue biopsy. Cytoplasmic contents including protein, mRNA, miRNA, and lipids have all been studied within the exosomal fraction. Many prospective urinary exosomal biomarkers have been successfully identified for a variety of kidney or genitourinary tract conditions; detection of systemic conditions may also be possible. Isolation and analysis of exosomes can be achieved by several approaches, although many require specialized equipment or involve lengthy protocols. The need for timely analysis in the clinical setting has driven considerable innovation with several promising options recently emerging. Consensus on exosome isolation, characterization, and normalization procedures would resolve critical clinical translational bottlenecks for existing candidate exosomal biomarkers and provide a template for additional discovery studies. 2017 Published by Elsevier Inc.

  18. Applications of bauxite residue: A mini-review.

    Science.gov (United States)

    Verma, Ajay S; Suri, Narendra M; Kant, Suman

    2017-10-01

    Bauxite residue is the waste generated during alumina production by Bayer's process. The amount of bauxite residue (40-50 wt%) generated depends on the quality of bauxite ore used for the processing. High alkalinity and high caustic content in bauxite residue causes environmental risk for fertile soil and ground water contamination. The caustic (NaOH) content in bauxite residue leads to human health risks, like dermal problems and irritation to eyes. Moreover, disposal of bauxite residue requires a large area; such problems can only be minimised by utilising bauxite residue effectively. For two decades, bauxite residue has been used as a binder in cement industries and filler/reinforcement for composite materials in the automobile industry. Valuable metals and oxides, like alumina (Al 2 O 3 ), titanium oxide (TiO 2 ) and iron oxide Fe 2 O 3 , were extracted from bauxite residue to reduce waste. Bauxite residue was utilised in construction and structure industries to make geopolymers. It was also used in the making of glass-ceramics and a coating material. Recently bauxite residue has been utilised to extract rare earth elements like scandium (Sc), yttrium (Y), lanthanum (La), cerium (Ce), neodymium (Nd) and dysprosium (Dy). In this review article, the mineralogical characteristics of bauxite residue are summarised and current progresses on utilisation of bauxite residue in different fields of science and engineering are presented in detail.

  19. Residual-stress measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ezeilo, A N; Webster, G A [Imperial College, London (United Kingdom); Webster, P J [Salford Univ. (United Kingdom)

    1997-04-01

    Because neutrons can penetrate distances of up to 50 mm in most engineering materials, this makes them unique for establishing residual-stress distributions non-destructively. D1A is particularly suited for through-surface measurements as it does not suffer from instrumental surface aberrations commonly found on multidetector instruments, while D20 is best for fast internal-strain scanning. Two examples for residual-stress measurements in a shot-peened material, and in a weld are presented to demonstrate the attractive features of both instruments. (author).

  20. Alpha spectrum analysis of 241Am in the urine

    International Nuclear Information System (INIS)

    Qiu Yongmei; Yang Yong

    2006-10-01

    With 241 Am as indicator, americium in the urine was concentrated by the method of codeposition, then it was purified by the method of anion exchange, at last, the americium was electroplated. 241 Am in the urine was analysed by six channel low level alpha measuring instrument and Alpha Spectrometer. The results show that the recovering ratio is beyond 60% under the condition that the indicator added to the urine is at the level of mBq. So, 241 Am in the urine can be quantitatively analysed by this method, uncertainty of the result is under 40%, detection limit of the instrument is under 10 -4 Bq. (authors)

  1. Ketones in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Ketones: Urine; p. 351. Joslin Diabetes ...

  2. Blood in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Hemoglobin, Urine; p. 325. Lab Tests ...

  3. Use of urine in snow to indicate condition of wolves

    Science.gov (United States)

    Mech, L.D.; Seal, U.S.; DelGiudice, G.D.

    1987-01-01

    Urine deposited in snow by wild gray wolves (Canis lupus) and by fed and fasted captive wolves was analyzed for urea nitrogen, calcium, sodium, potassium, and creatinine. Ratios of the elements with creatinine were considerably higher for fed than for fasted animals, and ratios for fed wolves compared favorably with ratios from wolf urine in snow along trails leading from kills. Thus, wolf urine in the snow can indicate whether wolves have fed recently, and a series of such urine collections from any given pack can indicate relative nutritional state.

  4. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  5. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  6. Bioassay method for Uranium in urine by Delay Neutron counting

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Sukarman-Aminjoyo

    1996-01-01

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 μg

  7. Comparative proteomic analysis of differentially expressed proteins in the urine of reservoir hosts of leptospirosis.

    Directory of Open Access Journals (Sweden)

    Jarlath E Nally

    Full Text Available Rattus norvegicus is a natural reservoir host for pathogenic species of Leptospira. Experimentally infected rats remain clinically normal, yet persistently excrete large numbers of leptospires from colonized renal tubules via urine, despite a specific host immune response. Whilst persistent renal colonization and shedding is facilitated in part by differential antigen expression by leptospires to evade host immune responses, there is limited understanding of kidney and urinary proteins expressed by the host that facilitates such biological equilibrium. Urine pellets were collected from experimentally infected rats shedding leptospires and compared to urine from non-infected controls spiked with in vitro cultivated leptospires for analysis by 2-D DIGE. Differentially expressed host proteins include membrane metallo endopeptidase, napsin A aspartic peptidase, vacuolar H+ATPase, kidney aminopeptidase and immunoglobulin G and A. Loa22, a virulence factor of Leptospira, as well as the GroEL, were increased in leptospires excreted in urine compared to in vitro cultivated leptospires. Urinary IgG from infected rats was specific for leptospires. Results confirm differential protein expression by both host and pathogen during chronic disease and include markers of kidney function and immunoglobulin which are potential biomarkers of infection.

  8. Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies.

    Science.gov (United States)

    Gagnebin, Yoric; Tonoli, David; Lescuyer, Pierre; Ponte, Belen; de Seigneux, Sophie; Martin, Pierre-Yves; Schappler, Julie; Boccard, Julien; Rudaz, Serge

    2017-02-22

    Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control-based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Designing with residual materials

    NARCIS (Netherlands)

    Walhout, W.; Wever, R.; Blom, E.; Addink-Dölle, L.; Tempelman, E.

    2013-01-01

    Many entrepreneurial businesses have attempted to create value based on the residual material streams of third parties. Based on ‘waste’ materials they designed products, around which they built their company. Such activities have the potential to yield sustainable products. Many of such companies

  10. QA/QC in pesticide residue analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, A [Agrochemicals Unit, Agency' s Laboratories, Seibersdorf (Austria)

    2002-07-01

    This paper outlines problems related to pesticide residue analysis in a regulatory laboratory that are related to: availability of reference materials, as over 1000 pesticide active ingredients are currently in use and over 400 crops represent a large part of a healthy diet; analysis time; availability of samples in sufficient numbers; uncertainties of the procedures.

  11. QA/QC in pesticide residue analysis

    International Nuclear Information System (INIS)

    Ambrus, A.

    2002-01-01

    This paper outlines problems related to pesticide residue analysis in a regulatory laboratory that are related to: availability of reference materials, as over 1000 pesticide active ingredients are currently in use and over 400 crops represent a large part of a healthy diet; analysis time; availability of samples in sufficient numbers; uncertainties of the procedures

  12. Bioassay method for Uranium in urine by Delay Neutron counting; Metoda Bioassay Uranium dalam urin dengan pencacahan Netron Kasip

    Energy Technology Data Exchange (ETDEWEB)

    Suratman,; Purwanto,; Sukarman-Aminjoyo, [Yogyakarta Nuclear Research Centre, National Atomic Energy Agency, Yogyakarta (Indonesia)

    1996-04-15

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 {mu}g.

  13. Environmental dredging residual generation and management.

    Science.gov (United States)

    Patmont, Clay; LaRosa, Paul; Narayanan, Raghav; Forrest, Casey

    2018-05-01

    The presence and magnitude of sediment contamination remaining in a completed dredge area can often dictate the success of an environmental dredging project. The need to better understand and manage this remaining contamination, referred to as "postdredging residuals," has increasingly been recognized by practitioners and investigators. Based on recent dredging projects with robust characterization programs, it is now understood that the residual contamination layer in the postdredging sediment comprises a mixture of contaminated sediments that originate from throughout the dredge cut. This mixture of contaminated sediments initially exhibits fluid mud properties that can contribute to sediment transport and contamination risk outside of the dredge area. This article reviews robust dredging residual evaluations recently performed in the United States and Canada, including the Hudson River, Lower Fox River, Ashtabula River, and Esquimalt Harbour, along with other projects. These data better inform the understanding of residuals generation, leading to improved models of dredging residual formation to inform remedy evaluation, selection, design, and implementation. Data from these projects confirm that the magnitude of dredging residuals is largely determined by site conditions, primarily in situ sediment fluidity or liquidity as measured by dry bulk density. While the generation of dredging residuals cannot be avoided, residuals can be successfully and efficiently managed through careful development and implementation of site-specific management plans. Integr Environ Assess Manag 2018;14:335-343. © 2018 The Authors. Integrated Environmental Assessment and Management Published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2018 The Authors. Integrated Environmental Assessment and Management Published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  14. Bioavailability in rats of bound residues from radishes treated with either radiolabeled dieldrin or carbofuran

    International Nuclear Information System (INIS)

    Khan, S.U.; Kacew, S.; Dupont, S.; Stratton, G.D. Jr.; Wheeler, W.B.

    1987-01-01

    The bioavailability of bound residues from radishes treated with [ 14 C]dieldrin and [ 14 C]carbofuran was investigated by feeding the rats 14 C material obtained after exhaustive solvent extraction. For comparison, nonextracted radishes were also fed to rats. The 14 C residues were predominantly excreted in feces. Urinary excretion of 14 C from rats fed nonextracted material was relatively greater than from those fed extracted radishes. The excreted material from rats fed dieldrin-treated radishes contained mainly parent compounds as residue. However, carbofuran and two of its metabolites, 3-hydroxycarbofuran and 3-ketocarbofuran, were present in feces and urine samples of rats fed carbofuran-treated radishes. These data demonstrated that bound residues in radishes treated with dieldrin and carbofuran have a low degree of bioavailability in rats. The results also show that bound residues in dieldrin-treated radishes would be more bioavailable than in the carbofuran-treated samples

  15. Radio-toxicological analysis of urine

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    The article is divided into two parts: general and technical. In the general part, a study of the behaviour of radioisotopes in the organism shows the hazards of internal contamination. In addition, the principle of the different methods for the estimation of this contamination is indicated. The second part, which is purely technical, describes some of the methods for urine analysis used in the S.H.A.R.P. radiotoxicology laboratory at the Saclay Nuclear Research Centre. The techniques relate to 239 Pu, 226 Ra, 90 Sr, natural Th, natural U and 233 U. Reprint of a paper published in Annales de Radiologie, Vol. 2, no. 9-10, p. 703-722, 1959 [fr

  16. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    Science.gov (United States)

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  17. Taking the Piss : Urine in Early Modern Europe

    NARCIS (Netherlands)

    Verwaal, Ruben

    2017-01-01

    As long as there have been humans, urine has been regularly discharged. You may not consider your urine very interesting. In fact, you may be very eager to leave your messy and leaky excretion behind in the bathroom. But have we always looked at this fluid with a feeling of disgust? What did people

  18. Domestic Cat (Felis silvestris catus) Urine Odour as a Potential ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the effects of cat urine odour extract on rodent pest species to reduce crop losses. Cat urine from the captured cats was drawn using cat catcher. Urinary catheter was inserted into the urethra up to the urinary bladder and a syringe attached to the urinary catheter was used to draw ...

  19. Exorphin Peptides in Urine with HPLC-MS/MS Detection

    OpenAIRE

    2015-01-01

    Exorphins have been found in urine from individuals diagnosed with autism spectrum disorders by HPLC techniques. However, several studies, using sophisticated analytical techniques , have reported negative findings. This made it necessary to improve our methods. The sample stability during transport and storage and the pre -analytical treatment of urines was improved by peptidase inhibition and solid ...

  20. Analyte variations in consecutive 24-hour urine collections in children.

    Science.gov (United States)

    Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett

    2017-12-01

    The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  1. Antibiotics susceptibility patterns of urine bacterial isolates in Zaria ...

    African Journals Online (AJOL)

    Purpose: The prevalence of E. coli, Ps. aeruginosa and Staph aureus isolates from urine of selected residents in Zaria was investigated. This was an attempt to elucidate the antibiotic susceptibility profiles of these bacteria commonly implicated in urinary tact infection. Methods: Urine samples collected from students of ...

  2. Acute and chronic urine retention among adults at the urology ...

    African Journals Online (AJOL)

    E.M.T. Yenli

    A complete work-up to establish the cause of urine ... acute or chronic urine retention was caused mainly by bladder cancer and neurogenic bladder. Initial and ... associated with a significantly impaired quality of life, stigmatiza- tion and a ..... to ensure that they remained healthy and did not have any infection connected with ...

  3. effects of artemether on the plasma and urine concentrations of ...

    African Journals Online (AJOL)

    Dr Komolafe

    2011-05-16

    May 16, 2011 ... degeneration of the renal tissue of rats, inability of the damaged kidneys to concentrate urine, which manifested as excessive water loss and electrolyte depletion. Key words: Artemether, electrolytes in plasma, urine concentrations, rats. INTRODUCTION. Artemether, one of the derivatives of artemisinin, is.

  4. Value of urine cytology in screening patients with prostatitis syndromes

    NARCIS (Netherlands)

    de la Rosette, J. J.; Hubregtse, M. R.; Wiersma, A. M.; Debruyne, F. M.

    1993-01-01

    We reviewed the results of urine cytology examination of 206 patients with a diagnosis of prostatitis syndromes in the period 1985-1991. The urine samples showed an incidence of 20.4% for slight to moderate atypia and 6.3% for severe atypia. In these patients, cystoscopy, bladder biopsies and

  5. Fertilizer value of urine in pumpkin (Cucurbita maxima L. cultivation

    Directory of Open Access Journals (Sweden)

    S.K. PRADHAN

    2008-12-01

    Full Text Available The fertilizer value of human urine was compared with mineral fertilizer in pumpkin (Cucurbita maxima cultivation at a dose of 113 kg N ha-1 with no-fertilization used as control. The growth of the vine was better in urine fertilized pumpkins than in mineral fertilized and non-fertilized pumpkins. Total fruit biomass was higher in mineral fertilized plants compared to urine fertilized and non-fertilized pumpkins. Urine fertilized pumpkins may have suffered from lower potassium or higher chloride, thus they produced fewer flowers and fruits. However, total fruit biomass and the number of fruits were slightly higher in urine fertilized plants than in their non-fertilized counterparts, i.e. 17.2 t ha-1 more pumpkin could be produced with urine fertilizer. The microbial hygiene quality as well as the contents of soluble sugars, protein and taste quality were similar in all treatments, but lower nitrate and higher chloride contents were recorded in urine fertilized pumpkins than other treatments. In conclusion, our study shows that the production rate of urine fertilized pumpkins was somewhat lower than mineral fertilized pumpkins but it was higher than non-fertilized pumpkins. The hygienic quality was equally good with all treatments.;

  6. Effectiveness of the Domestic Cat (Felis silvestris catus) Urine ...

    African Journals Online (AJOL)

    The stored cat urine was then thawed and mixed with maize starch to form a thick dough and then granulated and dried at room temperature before being packed in a hermetically closed jar. Initially, rodent foot marks on tracking soot coat tiles were used to estimate the rat population before the cat urine extracts application.

  7. The importance of cooling of urine samples for doping analysis

    NARCIS (Netherlands)

    Kuenen, J. Gijs; Konings, Wil N.

    Storing and transporting of urine samples for doping analysis, as performed by the anti-doping organizations associated with the World Anti-Doping Agency, does not include a specific protocol for cooled transport from the place of urine sampling to the doping laboratory, although low cost cooling

  8. Effects of diet composition on mutagenic activity in urine.

    Science.gov (United States)

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  9. Molecular neutron activation analysis of selenium metabolites in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Hansen, G.T.; Ebrahim, A.; Rack, E.P.

    1988-01-01

    Because of the biological importance of selenium in living biological systems, various analytical procedures have been developed for analysis of microquantities of elemental selenium, in urine, serum, and tissue. For urine selenium, these include atomic absorption spectrometry, solution absorption spectrometry, solution fluorescence spectrometry, volumetry, and neutron activation analysis. Of equal or greater importance is the determination of selenium metabolites present in urine for the purpose of describing the biological pathways for the metabolism of selenium in living organisms. While it is known from previous studies that trimethylselenonium ion (TMSe) is a major metabolite in urine, probably the result of reduction and methylation reaction, there are no definitive results in the literature indicating the nature or quantity of other selenium metabolic products in urine. Early techniques to measure TMSe levels in urine involved the use of the radiotracer 75 Se. Because of the long biological half-life of selenium and issues of radiation exposure, its use in humans has been limited. In this paper, the authors report the experimental procedure for the determination of total selenoamino acid concentration in urine and present total selenium values, and, where applicable, TMSe, SeO 2- 3 , and total selenoamino acid concentrations in the urine of normal and diseased subjects

  10. The role of uncentrifuged urine microscopy in the diagnosis of ...

    African Journals Online (AJOL)

    Background: Urinary tract infection (UTI) is one of the most common nosocomial bacterial infections prevalent in both males and females. UTI is diagnosed on the basis of clinical symptoms, microscopy and culture of urine. This study was done to establish the role of the routine uncentrifuged urine microscopy using culture ...

  11. SPE-NMR metabolite sub-profiling of urine

    NARCIS (Netherlands)

    Jacobs, D.M.; Spiesser, L.; Garnier, M.; Roo, de N.; Dorsten, van F.; Hollebrands, B.; Velzen, van E.; Draijer, R.; Duynhoven, van J.P.M.

    2012-01-01

    NMR-based metabolite profiling of urine is a fast and reproducible method for detection of numerous metabolites with diverse chemical properties. However, signal overlap in the (1)H NMR profiles of human urine may hamper quantification and identification of metabolites. Therefore, a new method has

  12. Polyglycolic acid (Dexon) sutures in Escherichia coli infected urine

    DEFF Research Database (Denmark)

    Hovendal, C P; Schwartz, W

    1979-01-01

    The tensile strength, knot strength and stretch of polyglycolic acid (Dexon) was studied after emersion in physiological saline, sterile urine and infected urine. Tests were made each day under controlled conditions over a 10 day period. The results are compared with those of other earlier studie...

  13. Effect Of Instructions About The Method Of Urine Collection And ...

    African Journals Online (AJOL)

    Despite the explanation, 15(23.1%) of the patients collected the urine samples wrongly and 44(67.7%) stored the samples for longer than one hour. Significant bacteriuria was more prevalent in 74.2% of patients who submitted their urine samples more than one hour after collection. Communication skill is important and ...

  14. Determination of natural thorium in urines; Dosage du thorium dans les urines

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of thorium in urine is described. After precipitation with ammonium hydroxide, dissolution of the precipitate, extraction at pH 4-4.2 with cupferron in chloroformic solution and mineralization, a colorimetric determination of thorium with thorin is performed. It is thus possible to detect about 2 {gamma} of thorium in the sample. (author) [French] Cet article decrit une technique de dosage du thorium dans l'urine. Apres precipitation par l'ammoniaque, remise en solution, extraction a pH 4-4,2 par le cupferron en solution chloroformique et mineralisation, le thorium est dose par colorimetrie avec le thorin. Cette methode permet de deceler environ 2 {gamma} de thorium dans l'echantillon. (auteur)

  15. Thermodynamic Effects of Replacements of Pro Residues in Helix Interiors of Maltose-Binding Protein

    OpenAIRE

    Prajapati, RS; Lingaraju, GM; Bacchawat, Kiran; Surolia, Avadhesha; Varadarajan, Raghavan

    2003-01-01

    Introduction of Pro residues into helix interiors results in protein destabilization. It is currently unclear if the converse substitution (i.e., replacement of Pro residues that naturally occur in helix interiors would be stabilizing). Maltose-binding protein is a large 370-amino acid protein that contains 21 Pro residues. Of these, three nonconserved residues (P48, P133, and P159) occur at helix interiors. Each of the residues was replaced with Ala and Ser. Stabilities were characterized by...

  16. Natural radionuclides in urine- and faeces samples; Natuerliche Radionuklide in Urin- und Stuhlproben

    Energy Technology Data Exchange (ETDEWEB)

    Froning, M.; Burow, M.; Ennen, R.; Hoelters, A.; Laumen-Sentis, S.; Zoriy, M. [Forschungszentrum Juelich GmbH (Germany). Geschaeftsbereich Sicherheit und Strahlenschutz

    2016-07-01

    In interpreting of measurement data for incorporation monitoring by excretion samples a clear distinction between the natural intake and the fraction subjected due to occupational exposure should be performed. At the present only a few data about an excretion of primordial elements such as {sup 238}U, {sup 232}Th are available in the literature. In the following study actual data measured in urine and faeces will be presented and discussed.

  17. Urine RAS components in mice and people with type 1 diabetes and chronic kidney disease.

    Science.gov (United States)

    Wysocki, Jan; Goodling, Anne; Burgaya, Mar; Whitlock, Kathryn; Ruzinski, John; Batlle, Daniel; Afkarian, Maryam

    2017-08-01

    The pathways implicated in diabetic kidney disease (DKD) are largely derived from animal models. To examine if alterations in renin-angiotensin system (RAS) in humans are concordant with those in rodent models, we measured concentration of angiotensinogen (AOG), cathepsin D (CTSD), angiotensin-converting enzyme (ACE), and ACE2 and enzymatic activities of ACE, ACE2, and aminopeptidase-A in FVB mice 13-20 wk after treatment with streptozotocin ( n = 9) or vehicle ( n = 15) and people with long-standing type 1 diabetes, with ( n = 37) or without ( n = 81) DKD. In streptozotocin-treated mice, urine AOG and CTSD were 10.4- and 3.0-fold higher than in controls, respectively ( P animals ( P animals ( P = 0.017). Compared with people without DKD, those with DKD had higher urine AOG (170 vs. 15 μg/g) and CTSD (147 vs. 31 μg/g). In people with DKD, urine ACE concentration was 1.8-fold higher (1.4 vs. 0.8 μg/g in those without DKD), while its enzymatic activity was 0.6-fold lower (1.0 vs. 1.6 × 10 9 RFU/g in those without DKD). Lower ACE activity, but not ACE protein concentration, was associated with ACE inhibitor (ACEI) treatment. After adjustment for clinical covariates, AOG, CTSD, ACE concentration, and ACE activity remained associated with DKD. In conclusion, in mice with streptozotocin-induced diabetes and in humans with DKD, urine concentrations and enzymatic activities of several RAS components are concordantly increased, consistent with enhanced RAS activity and greater angiotensin II formation. ACEI use was associated with a specific reduction in urine ACE activity, not ACE protein concentration, suggesting that it may be a marker of exposure to this widely-used therapy. Copyright © 2017 the American Physiological Society.

  18. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    Science.gov (United States)

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P creatinine concentrations were significantly lower in the R vs. L group (Pcreatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Bioassay techniques for {sup 55}Fe in urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Cregan, S P; Leon, J W; Linauskas, S H

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for {sup 55}Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH){sub 3}. precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs.

  20. Bioassay techniques for 55Fe in urine samples

    International Nuclear Information System (INIS)

    Cregan, S.P.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for 55 Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH) 3 . precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs

  1. Analysis of Urine as Indicators of Specific Body Conditions

    Science.gov (United States)

    Dey, Souradeep; Saha, Triya; Narendrakumar, Uttamchand

    2017-11-01

    Urinalysis can be defined as a procedure for examining various factors of urine, which include physical properties, particulate matter, cells, casts, crystals, organisms and solutes. Urinalysis is recommended to be a part of the initial examination of all patients as its cheap, feasible and gives productive results. This paper focuses on the analysis of urine collected at specific body conditions. Here we illustrate the urine profile of different persons having various body conditions, which include, having urinary tract infection, undergoing strenuous exercise, having back pain regularly, having very low urine output and a person who is on 24 hours of diet. Examination of urine collected from different persons having specific body conditions usually helps us in the diagnosis of various diseases, which it indicates.

  2. Urine nickel concentrations in nickel-exposed workers.

    Science.gov (United States)

    Bernacki, E J; Parsons, G E; Roy, B R; Mikac-Devic, M; Kennedy, C D; Sunderman, F W

    1978-01-01

    Electrothermal atomic absorption spectrometry was employed for analyses of nickel concentrations in urine samples from nickel-exposed workers in 10 occupational groups and from non-exposed workers in two control groups. Mean concentrations of nickel in urine were greatest in workers who were exposed to inhalation of aerosols of soluble nickel salts (e.g., workers in nickel plating operations and in an electrolytic nickel refinery). Less marked increases in urine nickel concentrations were found in groups of metal sprayers, nickel battery workers, bench mechanics and are welders. No significant increases in mean concentrations of nickel were found in urine samples from workers who performed grinding, buffing and polishing of nickel-containing alloys or workers in a coal gasification plant who employed Raney nickel as a hydrogenation catalyst. Measurements of nickel concentrations in urine are more sensitive and practical than measurements of serum nickel concentrations for evaluation of nickel exposures in industrial workers.

  3. A simple method for estimation of phosphorous in urine

    International Nuclear Information System (INIS)

    Chaudhary, Seema; Gondane, Sonali; Sawant, Pramilla D.; Rao, D.D.

    2016-01-01

    Following internal contamination of 32 P, it is preferentially eliminated from the body in urine. It is estimated by in-situ precipitation of ammonium molybdo-phosphate (AMP) in urine followed by gross beta counting. The amount of AMP formed in-situ depends on the amount of stable phosphorous (P) present in the urine and hence, it was essential to generate information regarding urinary excretion of stable P. If amount of P excreted is significant then the amount of AMP formed would correspondingly increase leading to absorption of some of the β particles. The present study was taken up for the estimation of daily urinary excretion of P using the phospho-molybdate spectrophotometry method. Few urine samples received from radiation workers were analyzed and based on the observed range of stable P in urine; volume of sample required for 32 P estimation was finalized

  4. Tritium analysis of urine samples from the general Korean public.

    Science.gov (United States)

    Yoon, Seokwon; Ha, Wi-Ho; Lee, Seung-Sook

    2013-11-01

    The tritium concentrations of urine samples and the effective dose of the general Korean public were evaluated. To achieve accurate HTO analysis of urine samples, we established the optimal conditions for measuring the HTO content of urine samples. Urine samples from 50 Koreans who do not work at a nuclear facility were analyzed on the basis of the results. The average urine analysis result was 2.8 ±1 .4 Bq/L, and the range was 1.8-5.6 Bq/L. The measured values were lower than those reported for other countries. These results show that environmental factors and lifestyle differences are the main factors affecting the tritium level of the general public. © 2013 Elsevier Ltd. All rights reserved.

  5. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan; Fidelis, Krzysztof; Tramontano, Anna; Kryshtafovych, Andriy

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures

  6. Depletion of penicillin G residues in heavy sows after intramuscular injection. Part II: application of kidney inhibition swab tests.

    Science.gov (United States)

    Shelver, Weilin L; Lupton, Sara J; Newman, David J; Larsen, Steven; Smith, David J

    2014-07-30

    Sows (n = 126; 228 ± 30.1 kg) were administered daily IM doses of penicillin G procaine (33 000 IU/kg bw; 5× the label dose) for 3 consecutive days using three different administration patterns. Within treatment, six sows each were slaughtered on withdrawal day 5, 10, 15, 20, 25, 32, and 39. Tissues (injection site, kidney, liver, skeletal muscle) or body fluids (serum and urine) were screened for penicillin G using the KIS test, recently adopted by the USDA Food Safety and Inspection Service. The IM administration patterns had no discernible effect on penicillin G depletion. Residues were depleted more rapidly from liver and skeletal muscle and more slowly from kidney and urine. Kidney was the most sensitive and suitable tissue for detecting penicillin G residues on-site, with two positive results after a 39-day withdrawal period. Urine was the most suitable ante-mortem surrogate to predict the results of kidney tests.

  7. First-void urine: A potential biomarker source for triage of high-risk human papillomavirus infected women.

    Science.gov (United States)

    Van Keer, Severien; Pattyn, Jade; Tjalma, Wiebren A A; Van Ostade, Xaveer; Ieven, Margareta; Van Damme, Pierre; Vorsters, Alex

    2017-09-01

    Great interest has been directed towards the use of first-void urine as a liquid biopsy for high-risk human papillomavirus DNA testing. Despite the high correlations established between urinary and cervical infections, human papillomavirus testing is unable to distinguish between productive and transforming high-risk infections that have the tendency to progress to cervical cancer. Thus far, investigations have been primarily confined to the identification of biomarkers for triage of high-risk human papillomavirus-positive women in cervicovaginal specimens and tissue biopsies. This paper reviews urinary biomarkers for cervical cancer and triage of high-risk human papillomavirus infections and elaborates on the opportunities and challenges that have emerged regarding the use of first-void urine as a liquid biopsy for the analysis of both morphological- (conventional cytology and novel immunohistochemical techniques) and molecular-based (HPV16/18 genotyping, host/viral gene methylation, RNA, and proteins) biomarkers. A literature search was performed in PubMed and Web of Science for studies investigating the use of urine as a biomarker source for cervical cancer screening. Five studies were identified reporting on biomarkers that are still in preclinical exploratory or clinical assay development phases and on assessments of non-invasive (urine) samples. Although large-scale validation studies are still needed, we conclude that methylation of both host and viral genes in urine has been proven feasible for use as a molecular cervical cancer triage and screening biomarker in phase two studies. This is especially promising and underscores our hypothesis that human papillomavirus DNA and candidate human and viral biomarkers are washed away with the initial, first-void urine, together with exfoliated cells, debris and impurities that line the urethra opening. Similar to the limitations of self-collected cervicovaginal samples, first-void urine will likely not fulfil the

  8. Determination of Antibiotic Residues in Milk by Microbial Inhibitory Tests

    Directory of Open Access Journals (Sweden)

    Juščáková D.

    2017-09-01

    Full Text Available Undesirable substances enter the organism of animals mostly via feed, water or veterinary medicines and their residues pass subsequently into the products of animal origin. In dairy cows, sheep and goats these residues are eliminated particularly in milk. Milk intended for human consumption must comply with safety criteria also with respect to residues of antibiotics. The aim of this study was to determine the presence or absence of antibiotic residues in the milk using the tests Milchtest and Premi®Test. While the Milchtest was developed for the determination of antibiotic residues in cow, sheep and goat milk, the Premi®Test is intended for the determination of antibiotic residues in meat juice, liver, kidneys, fish, eggs and in the urine of animals treated with antibiotics. As examined matrices, we used 45 samples of raw cow’s milk collected at 3 agricultural farms and 10 samples of milk offered to consumers at grocery stores. When using the Milchtest, 8 samples tested positive and 10 provided dubious results while testing with the Premi®Test showed that only 6 samples were positive for antibiotics. Comparison of the results confirmed a higher detection sensitivity of Milchtest reflected in higher numbers of positive samples and the detection of dubious results in samples of raw cow’s milk. However, it should be noted that even the Premi®Test, although not intended preferably for the determination of antibiotics in milk, can be used, if needed, for the preliminary screening of antibiotic residues in such a matrix.

  9. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Dietz, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Kaminski, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Shkrob, I. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial, extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.

  10. Residual Defect Density in Random Disks Deposits.

    Science.gov (United States)

    Topic, Nikola; Pöschel, Thorsten; Gallas, Jason A C

    2015-08-03

    We investigate the residual distribution of structural defects in very tall packings of disks deposited randomly in large channels. By performing simulations involving the sedimentation of up to 50 × 10(9) particles we find all deposits to consistently show a non-zero residual density of defects obeying a characteristic power-law as a function of the channel width. This remarkable finding corrects the widespread belief that the density of defects should vanish algebraically with growing height. A non-zero residual density of defects implies a type of long-range spatial order in the packing, as opposed to only local ordering. In addition, we find deposits of particles to involve considerably less randomness than generally presumed.

  11. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    Science.gov (United States)

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  12. Effects of Adopting Different Kinds of Collecting Method for Years on Film Residual Coefficient and Maize Yields

    OpenAIRE

    TANG Wen-xue; MA Zhong-ming; WEI Tao

    2017-01-01

    Wide usage of mulching technology has increased crop yields, but the large amounts of mulching film residue resulting from widespread use of plastic film in China has brought about a series of pollution hazards. Based on a 4-year (2011-2014) long-term experiment, the effects of different kinds of collecting mothod (zero plastic film residues, conventional plastic film residues, whole plastic film residues remainded) on plastic film residues, residual coefficient and maize yield were explored....

  13. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  14. Disposal of Rocky Flats residues as waste

    International Nuclear Information System (INIS)

    Dustin, D.F.; Sendelweck, V.S.

    1993-01-01

    Work is underway at the Rocky Flats Plant to evaluate alternatives for the removal of a large inventory of plutonium-contaminated residues from the plant. One alternative under consideration is to package the residues as transuranic wastes for ultimate shipment to the Waste Isolation Pilot Plant. Current waste acceptance criteria and transportation regulations require that approximately 1000 cubic yards of residues be repackaged to produce over 20,000 cubic yards of WIPP certified waste. The major regulatory drivers leading to this increase in waste volume are the fissile gram equivalent, surface radiation dose rate, and thermal power limits. In the interest of waste minimization, analyses have been conducted to determine, for each residue type, the controlling criterion leading to the volume increase, the impact of relaxing that criterion on subsequent waste volume, and the means by which rules changes may be implemented. The results of this study have identified the most appropriate changes to be proposed in regulatory requirements in order to minimize the costs of disposing of Rocky Flats residues as transuranic wastes

  15. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  16. Drug and chemical residues in domestic animals.

    Science.gov (United States)

    Mussman, H C

    1975-02-01

    Given the large number of chemical substances that may find their way into the food supply, a system is needed to monitor their presence. The U. S. Department of Agriculture's Meat and Poultry Inspection Program routinely tests for chemical residues in animals coming to slaughter. Pesticides, heavy metals, growth promotants (hormones and hormonelike agents), and antibiotics are included. Samples are taken statistically so that inferences as to national incidence of residues can be drawn. When a problem is identified, a more selective sampling is designed to help follow up on the initial regulatory action. In testing for pesticides, only DDT and dieldrin are found with any frequency and their levels are decreasing; violative residues of any chlorinated hydrocarbon are generally a result of an industrial accident rather than agricultural usage. Analyses for heavy metals have revealed detectable levels of mercury, lead, and others, but none at levels that are considered a health hazard. Of the hormone or hormonelike substances, only diethylstilbestrol has been a residue problem and its future is uncertain. The most extensive monitoring for veterinary drugs is on the antimicrobials, including sulfonamides, streptomycin, and the tetracycline group of antibiotics that constitute the bulk of the violations; their simultaneous use prophylactically and therapeutically has contributed to the problem in certain cases. A strong, well-designed user education program on proper application of pesticides, chemicals, and veterinary drugs appears to be one method of reducing the incidence of unwanted residues.

  17. Machine for compacting solid residues

    International Nuclear Information System (INIS)

    Herzog, J.

    1981-11-01

    Machine for compacting solid residues, particularly bulky radioactive residues, constituted of a horizontally actuated punch and a fixed compression anvil, in which the residues are first compacted horizontally and then vertically. Its salient characteristic is that the punch and the compression anvil have embossments on the compression side and interpenetrating plates in the compression position [fr

  18. Detection of herbicides in the urine of pet dogs following home lawn chemical application

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, Deborah W., E-mail: knappd@purdue.edu [Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN (United States); Purdue University Center for Cancer Research and Purdue Oncological Sciences Center, West Lafayette, IN (United States); Peer, Wendy A.; Conteh, Abass; Diggs, Alfred R. [Department of Horticulture and Landscape Architecture, Purdue University, West Lafayette, IN (United States); Cooper, Bruce R. [Bindley Bioscience Center, Purdue University, West Lafayette, IN (United States); Glickman, Nita W. [Department of Emergency Medicine, University of North Carolina, Chapel Hill, NC (United States); Bonney, Patty L.; Stewart, Jane C. [Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN (United States); Glickman, Lawrence T. [Department of Emergency Medicine, University of North Carolina, Chapel Hill, NC (United States); Murphy, Angus S. [Department of Horticulture and Landscape Architecture, Purdue University, West Lafayette, IN (United States)

    2013-07-01

    Exposure to herbicide-treated lawns has been associated with significantly higher bladder cancer risk in dogs. This work was performed to further characterize lawn chemical exposures in dogs, and to determine environmental factors associated with chemical residence time on grass. In addition to concern for canine health, a strong justification for the work was that dogs may serve as sentinels for potentially harmful environmental exposures in humans. Experimentally, herbicides [2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxypropionic acid (MCPP), dicamba] were applied to grass plots under different conditions (e.g., green, dry brown, wet, and recently mowed grass). Chemicals in dislodgeable residues were measured by LC-MS at 0.17, 1, 24, 48, 72 h post treatment. In a separate study, 2,4-D, MCPP, and dithiopyr concentrations were measured in the urine of dogs and in dislodgeable grass residues in households that applied or did not apply chemicals in the preceding 48 h. Chemicals were measured at 0, 24, and 48 h post application in treated households and at time 0 in untreated control households. Residence times of 2,4-D, MCPP, and dicamba were significantly prolonged (P < 0.05) on dry brown grass compared to green grass. Chemicals were detected in the urine of dogs in 14 of 25 households before lawn treatment, in 19 of 25 households after lawn treatment, and in 4 of 8 untreated households. Chemicals were commonly detected in grass residues from treated lawns, and from untreated lawns suggesting chemical drift from nearby treated areas. Thus dogs could be exposed to chemicals through contact with their own lawn (treated or contaminated through drift) or through contact with other grassy areas if they travel. The length of time to restrict a dog's access to treated lawns following treatment remains to be defined. Further study is indicated to assess the risks of herbicide exposure in humans and dogs. - Highlights: • Lawn chemicals were commonly

  19. Detection of herbicides in the urine of pet dogs following home lawn chemical application

    International Nuclear Information System (INIS)

    Knapp, Deborah W.; Peer, Wendy A.; Conteh, Abass; Diggs, Alfred R.; Cooper, Bruce R.; Glickman, Nita W.; Bonney, Patty L.; Stewart, Jane C.; Glickman, Lawrence T.; Murphy, Angus S.

    2013-01-01

    Exposure to herbicide-treated lawns has been associated with significantly higher bladder cancer risk in dogs. This work was performed to further characterize lawn chemical exposures in dogs, and to determine environmental factors associated with chemical residence time on grass. In addition to concern for canine health, a strong justification for the work was that dogs may serve as sentinels for potentially harmful environmental exposures in humans. Experimentally, herbicides [2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxypropionic acid (MCPP), dicamba] were applied to grass plots under different conditions (e.g., green, dry brown, wet, and recently mowed grass). Chemicals in dislodgeable residues were measured by LC-MS at 0.17, 1, 24, 48, 72 h post treatment. In a separate study, 2,4-D, MCPP, and dithiopyr concentrations were measured in the urine of dogs and in dislodgeable grass residues in households that applied or did not apply chemicals in the preceding 48 h. Chemicals were measured at 0, 24, and 48 h post application in treated households and at time 0 in untreated control households. Residence times of 2,4-D, MCPP, and dicamba were significantly prolonged (P < 0.05) on dry brown grass compared to green grass. Chemicals were detected in the urine of dogs in 14 of 25 households before lawn treatment, in 19 of 25 households after lawn treatment, and in 4 of 8 untreated households. Chemicals were commonly detected in grass residues from treated lawns, and from untreated lawns suggesting chemical drift from nearby treated areas. Thus dogs could be exposed to chemicals through contact with their own lawn (treated or contaminated through drift) or through contact with other grassy areas if they travel. The length of time to restrict a dog's access to treated lawns following treatment remains to be defined. Further study is indicated to assess the risks of herbicide exposure in humans and dogs. - Highlights: • Lawn chemicals were commonly

  20. Estimate of dietary phosphorus intake using 24-h urine collection

    Science.gov (United States)

    Morimoto, Yuuka; Sakuma, Masae; Ohta, Hiroyuki; Suzuki, Akitsu; Matsushita, Asami; Umeda, Minako; Ishikawa, Makoto; Taketani, Yutaka; Takeda, Eiji; Arai, Hidekazu

    2014-01-01

    Increases in serum phosphorus levels and dietary phosphorus intake induces vascular calcification, arterial sclerosis and cardiovascular diseases. Limiting phosphorus intake is advisable, however, no assessment methods are capable of estimating dietary phosphorus intake. We hypothesized that urinary phosphorus excretion can be translated into estimation of dietary phosphorus intake, and we evaluated whether a 24-h urine collection method could estimate dietary phosphorus intake. Thirty two healthy subjects were recruited for this study. Subjects collected urine samples over 24 h and weighed dietary records. We calculated dietary protein intake and phosphorus intake from dietary records and urine collection, and investigated associations between the two methods in estimating protein and phosphorus intake. Significant positive correlations were observed between dietary records and UC for protein and phosphorus intake. The average intakes determined from dietary records were significantly higher than from urine collection for both protein and phosphorus. There was a significant positive correlation between both the phosphorus and protein difference in dietary records and urine collection. The phosphorus-protein ratio in urine collection was significantly higher than in dietary records. Our data indicated that the 24-h urine collection method can estimate the amount of dietary phosphorus intake, and the results were superior to estimation by weighed dietary record. PMID:25120281

  1. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  2. Use of diluted urine for cultivation of Chlorella vulgaris.

    Science.gov (United States)

    Jaatinen, Sanna; Lakaniemi, Aino-Maija; Rintala, Jukka

    2016-01-01

    Our aim was to study the biomass growth of microalga Chlorella vulgaris using diluted human urine as a sole nutrient source. Batch cultivations (21 days) were conducted in five different urine dilutions (1:25-1:300), in 1:100-diluted urine as such and with added trace elements, and as a reference, in artificial growth medium. The highest biomass density was obtained in 1:100-diluted urine with and without additional trace elements (0.73 and 0.60 g L(-1), respectively). Similar biomass growth trends and densities were obtained with 1:25- and 1:300-diluted urine (0.52 vs. 0.48 gVSS L(-1)) indicating that urine at dilution 1:25 can be used to cultivate microalgal based biomass. Interestingly, even 1:300-diluted urine contained sufficiently nutrients and trace elements to support biomass growth. Biomass production was similar despite pH-variation from < 5 to 9 in different incubations indicating robustness of the biomass growth. Ammonium formation did not inhibit overall biomass growth. At the beginning of cultivation, the majority of the biomass consisted of living algal cells, while towards the end, their share decreased and the estimated share of bacteria and cell debris increased.

  3. Urine Trefoil Factors as Prognostic Biomarkers in Chronic Kidney Disease.

    Science.gov (United States)

    Yamanari, Toshio; Sugiyama, Hitoshi; Tanaka, Keiko; Morinaga, Hiroshi; Kitagawa, Masashi; Onishi, Akifumi; Ogawa-Akiyama, Ayu; Kano, Yuzuki; Mise, Koki; Ohmoto, Yasukazu; Shikata, Kenichi; Wada, Jun

    2018-01-01

    Trefoil factor family (TFF) peptides are increased in serum and urine in patients with chronic kidney disease (CKD). However, whether the levels of TFF predict the progression of CKD remains to be elucidated. We determined the TFF levels using peptide-specific ELISA in spot urine samples and performed a prospective cohort study. The association between the levels of urine TFFs and other urine biomarkers as well as the renal prognosis was analyzed in 216 CKD patients (mean age: 53.7 years, 47.7% female, 56.9% with chronic glomerulonephritis, and mean eGFR: 58.5 ml/min/1.73 m 2 ). The urine TFF1 and TFF3 levels significantly increased with the progression of CKD stages, but not the urine TFF2 levels. The TFF1 and TFF3 peptide levels predicted the progression of CKD ≥ stage 3b by ROC analysis (AUC 0.750 and 0.879, resp.); however, TFF3 alone predicted CKD progression in a multivariate logistic regression analysis (odds ratio 3.854, 95% confidence interval 1.316-11.55). The Kaplan-Meier survival curves demonstrated that patients with a higher TFF1 and TFF3 alone, or in combination with macroalbuminuria, had a significantly worse renal prognosis. The data suggested that urine TFF peptides are associated with renal progression and the outcomes in patients with CKD.

  4. Quadratic residues and non-residues selected topics

    CERN Document Server

    Wright, Steve

    2016-01-01

    This book offers an account of the classical theory of quadratic residues and non-residues with the goal of using that theory as a lens through which to view the development of some of the fundamental methods employed in modern elementary, algebraic, and analytic number theory. The first three chapters present some basic facts and the history of quadratic residues and non-residues and discuss various proofs of the Law of Quadratic Reciprosity in depth, with an emphasis on the six proofs that Gauss published. The remaining seven chapters explore some interesting applications of the Law of Quadratic Reciprocity, prove some results concerning the distribution and arithmetic structure of quadratic residues and non-residues, provide a detailed proof of Dirichlet’s Class-Number Formula, and discuss the question of whether quadratic residues are randomly distributed. The text is a valuable resource for graduate and advanced undergraduate students as well as for mathematicians interested in number theory.

  5. Iodine-125 radioimmunoassay for the direct detection of benzodiazepines in blood and urine

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, C.P.; Stead, A.H.; Mason, P.A.; Law, B.; Moffat, A.C.; McBrien, M.; Cosby, S.

    1986-05-01

    A radioimmunoassay (RIA) for the direct detection of benzodiazepines in blood and urine is described. It is based on a commercially available antiserum and an easily synthesised radio-iodinated derivative of clonazepam that allows the use of relatively simple gamma-counting procedures. The assay can detect low therapeutic levels of all of the benzodiazepines currently available in the UK in 50-..mu..l samples of blood and urine (1-50 ng ml/sup -1/, depending on the drug); no prior sample preparation is required. It is inexpensive, rapid, simple to perform and is broadly specific for the benzodiazepine class of drugs. The assay offers a most suitable means of screening large numbers of samples of forensic interest for the presence of the benzodiazepines.

  6. An iodine-125 radioimmunoassay for the direct detection of benzodiazepines in blood and urine

    International Nuclear Information System (INIS)

    Goddard, C.P.; Stead, A.H.; Mason, P.A.; Law, B.; Moffat, A.C.; McBrien, M.; Cosby, S.

    1986-01-01

    A radioimmunoassay (RIA) for the direct detection of benzodiazepines in blood and urine is described. It is based on a commercially available antiserum and an easily synthesised radio-iodinated derivative of clonazepam that allows the use of relatively simple gamma-counting procedures. The assay can detect low therapeutic levels of all of the benzodiazepines currently available in the UK in 50-μl samples of blood and urine (1-50 ng ml -1 , depending on the drug); no prior sample preparation is required. It is inexpensive, rapid, simple to perform and is broadly specific for the benzodiazepine class of drugs. The assay offers a most suitable means of screening large numbers of samples of forensic interest for the presence of the benzodiazepines. (author)

  7. Clean-voided urine culture in surveying populations for urinary tract infection

    Energy Technology Data Exchange (ETDEWEB)

    Switzer, S

    1959-07-01

    As part of a large-scale epidemiologic survey of A Bomb survivors being conducted by the ABCC in Hiroshima, the feasibility of male and female subjects collecting their own clean-voided specimens was tested. Clean-voided, midstream urine specimens were obtained from 441 ambulant, non-hospital subjects and examined by means of the Gram-stain and quantitative culture technique. Collection was performed by the subjects themselves after appropriate instruction, and this yielded specimens satisfactory for quantitative study. The gram-stain of the urinary sediment proved efficient in presaging true bacilluria. The presence of abundant Gram-negative organisms in a fresh urine sediment may be considered presumptive evidence of a urinary tract infection. Utilizing pre-poured, selective media, it was found that counts exceeding 50,000 to 100,000 col./ml. indicate true bacteriuria and will be confirmed by repeated studies. 9 references, 2 figures, 4 tables.

  8. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review

    KAUST Repository

    Emwas, Abdul-Hamid M.

    2014-11-21

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  9. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review.

    Science.gov (United States)

    Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  10. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review

    KAUST Repository

    Emwas, Abdul-Hamid M.; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M.; Ryan, Danielle; Merzaban, Jasmeen; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G. A.; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S.

    2014-01-01

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  11. Mass spectrometric based approaches in urine metabolomics and biomarker discovery.

    Science.gov (United States)

    Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas

    2017-03-01

    Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing

  12. Fluctuations of nickel concentrations in urine of electroplating workers

    International Nuclear Information System (INIS)

    Bernacki, E.J.; Zygowicz, E.; Sunderman, F.W. Jr.

    1980-01-01

    Nickel analyses were performed by electrothermal atomic absorption spectrometry upon urine specimens obtained from electroplating workers at the beginning, middle and end of the work-shift. The means (+- S.D.) for nickel concentrations in urine specimens from seven electroplating workers on three regular workdays were: 34 +- 32 μg/L (pre-shift); 64 +- μg/L (mid-shift) and 46 +- μg/L (end-shift), compared to 2.7 +- 1.6 μg/L (pre-shift) in 19 controls (hospital workers). Nickel concentrations in urine specimens from six electroplating workers on the first workday after a two-week vacation averaged: 5 +- 3 μg/L (pre-shift); 9 +- 6 μg/L (mid-shift), and 12 +- 6 μg/L (end-shift). Nickel concentrations in personal air samples (seven hours) collected from the breathing zones of five electroplating workers on three regular workdays averaged 9.3 +- 4.4 μg/m 3 . Nickel concentrations in the air samples were correlated with nickel concentrations in end-shift urine specimens (corr. coef. = 0.70; P < 0.05), but were not correlated with nickel concentrations in pre-shift or mid-shift urine specimens. In view of the fluctuations of urine nickel concentrations that occur during the work-shift, the authors recommend that nickel analyses of eight hour urine specimens be used routinely to monitor occupational exposures to nickel. In situations where timed urine collections are impractical, analyses of end-shift urine specimens are the best alternative

  13. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  14. Metabolites of cannabidiol identified in human urine.

    Science.gov (United States)

    Harvey, D J; Mechoulam, R

    1990-03-01

    1. Urine from a dystonic patient treated with cannabidiol (CBD) was examined by g.l.c.-mass spectrometry for CBD metabolites. Metabolites were identified as their trimethylsilyl (TMS), [2H9]TMS, and methyl ester/TMS derivatives and as the TMS derivatives of the product of lithium aluminium deuteride reduction. 2. Thirty-three metabolites were identified in addition to unmetabolized CBD, and a further four metabolites were partially characterized. 3. The major metabolic route was hydroxylation and oxidation at C-7 followed by further hydroxylation in the pentyl and propenyl groups to give 1"-, 2"-, 3"-, 4"- and 10-hydroxy derivatives of CBD-7-oic acid. Other metabolites, mainly acids, were formed by beta-oxidation and related biotransformations from the pentyl side-chain and these were also hydroxylated at C-6 or C-7. The major oxidized metabolite was CBD-7-oic acid containing a hydroxyethyl side-chain. 4. Two 8,9-dihydroxy compounds, presumably derived from the corresponding epoxide were identified. 5. Also present were several cyclized cannabinoids including delta-6- and delta-1-tetrahydrocannabinol and cannabinol. 6. This is the first metabolic study of CBD in humans; most observed metabolic routes were typical of those found for CBD and related cannabinoids in other species.

  15. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  16. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  17. Discordant genotyping results using DNA isolated from anti-doping control urine samples.

    Science.gov (United States)

    Choong, Eva; Schulze, Jenny J; Ericsson, Magnus; Rane, Anders; Ekström, Lena

    2017-07-01

    The UGT2B17 gene deletion polymorphism is known to correlate to urinary concentration of testosterone-glucuronide and hence this genotype exerts a large impact on the testosterone/epitestosterone (T/E) ratio, a biomarker for testosterone doping. The objective of this study was to assess if DNA isolated from athletes' urine samples (n = 713) obtained in routine doping controls could be targeted for genotyping analysis for future integration in the athlete's passport. A control population (n = 21) including both urine and blood DNA was used for genotyping concordance test. Another aim was to study a large group (n = 596) of authentic elite athletes in respect of urinary steroid profile in relation to genetic variation. First we found that the genotype results when using urine-derived DNA did not correlate sufficiently with the genotype obtained from whole blood DNA. Secondly we found males with one or two UGT2B17 alleles had higher T/E (mean 1.63 ± 0.93) than females (mean 1.28 ± 1.08), p˂0.001. Unexpectedly, we found that several male del/del athletes in power sports had a T/E ˃1. If men in power sport exert a different urinary steroid profile needs to be further investigated. The other polymorphisms investigated in the CYP17A1, UGT2B7 and UGT2B15 genes did not show any associations with testosterone and epitestosterone concentrations. Our results show that genotyping using urine samples according to our method is not useful in an anti-doping setting. Instead, it is of importance for the anti-doping test programs to include baseline values in the ABP to minimize any putative impact of genotype. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Antibiotic use in heavy pigs: Comparison between urine and muscle samples from food chain animals analysed by HPLC-MS/MS.

    Science.gov (United States)

    Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco

    2017-11-15

    The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.

  19. Forest residues in cattle feed

    Directory of Open Access Journals (Sweden)

    João Elzeário Castelo Branco Iapichini

    2012-12-01

    Full Text Available The ruminants are capable of converting low-quality food, when they are complementes with high-energy source. Through the use of regional agricultural residues is possible to conduct more economical production systems, since energetic foods have high cost in animal production. There is very abundant availability of residues in agroforestry activities worldwide, so that if a small fraction of them were used with appropriate technical criteria they could largely meet the needs of existing herds in the world and thus meet the demands of consumption of protein of animal origin. The Southwest Region of São Paulo State has large area occupied by reforestation and wide availability of non-timber forest residues, which may represent more concentrated energetic food for ruminant production. This experiment aimed to evaluate the acceptability of ground pine (20, 30 and 40%, replacing part of the energetic food (corn, present in the composition of the concentrate and was performed at the Experimental Station of Itapetininga - Forest Institute / SMA, in the dry season of 2011. It were used four crossbred steers, mean 18 months old, average body weight of 250 kg, housed in a paddock provided with water ad libitum and covered troughs for supplementation with the experimental diet. The adjustment period of the animals was of 07 days and the measurement of the levels of consumption, physiological changes, acceptability and physiological parameters were observed during the following 25 days. The concentrate supplement was formulated based on corn (76.2%, Soybean Meal (20%, urea (2%, Ammonium sulfate (0.4%, calcite (1.4%, Mineral Core (1% and finely ground Pine Cone, replacing corn. In preparing food, the formulas were prepared to make them isoproteic/energetic, containing the following nutrient levels: 22% Crude Protein (CP and 79% of Total Nutrients (TDN. The animals received the supplement in three steps for each level of cone replaced, being offered in the

  20. Triggered Urine Interleukin-6 Correlates to Severity of Symptoms in Nonfebrile Lower Urinary Tract Infections.

    Science.gov (United States)

    Sundén, Fredrik; Butler, Daniel; Wullt, Björn

    2017-07-01

    Objective diagnosis of symptomatic urinary tract infections in patients prone to asymptomatic bacteriuria is compromised by local host responses that are already present and the positive urine culture. We investigated interleukin-6 as a biomarker for nonfebrile urinary tract infection severity and diagnostic thresholds for interleukin-6 and 8, and neutrophils to differentiate between asymptomatic bacteriuria and urinary tract infection. Patients with residual urine and neurogenic bladders due to spinal lesions included in a long-term Escherichia coli 83972 asymptomatic bacteriuria inoculation trial were monitored for 2 years. Symptom scoring and urine sampling to estimate interleukin-6 and 8, and neutrophils were performed regularly monthly and at urinary tract infection episodes. Patients were followed in the complete study for a mean of 19 months (range 10 to 27) and those with asymptomatic bacteriuria with E. coli 83972 were followed a mean of 11 months (range 4 to 19). A total of 37 nonfebrile urinary tract infection episodes with complete data on interleukin-6 and 8, neutrophils and symptom scoring were documented. Interleukin-6 was the only marker that persistently increased during urinary tract infection compared to asymptomatic bacteriuria in pooled and paired intra-individual comparisons (p urinary tract infection symptoms (p urinary tract infection episodes. However, in urinary tract infections with worse symptoms interleukin-6 and neutrophils demonstrated equal good/excellent outcomes. Triggered interleukin-6 correlated to urinary tract infection symptom severity and demonstrated a promising differential diagnostic capacity to discriminate urinary tract infection from asymptomatic bacteriuria. Future studies should explore interleukin-6 as a biomarker of urinary tract infection severity and assess the treatment indication in nonfebrile urinary tract infections. Copyright © 2017 American Urological Association Education and Research, Inc. Published by

  1. Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis

    Science.gov (United States)

    Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.

    2015-01-01

    , time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the

  2. Urine testing and urinary tract infections in febrile infants seen in office settings: the Pediatric Research in Office Settings' Febrile Infant Study.

    Science.gov (United States)

    Newman, Thomas B; Bernzweig, Jane A; Takayama, John I; Finch, Stacia A; Wasserman, Richard C; Pantell, Robert H

    2002-01-01

    To determine the predictors and results of urine testing of young febrile infants seen in office settings. Prospective cohort study. Offices of 573 pediatric practitioners from 219 practices in the American Academy of Pediatrics Pediatric Research in Office Settings' research network. A total of 3066 infants 3 months or younger with temperatures of 38 degrees C or higher were evaluated and treated according to the judgment of their practitioners. Urine testing results, early and late urinary tract infections (UTIs), and UTIs with bacteremia. Fifty-four percent of the infants initially had urine tested, of whom 10% had a UTI. The height of the fever was associated with urine testing and a UTI among those tested (adjusted odds ratio per degree Celsius, 2.2 for both). Younger age, ill appearance, and lack of a fever source were associated with urine testing but not with a UTI, whereas lack of circumcision (adjusted odds ratio, 11.6), female sex (adjusted odds ratio, 5.4), and longer duration of fever (adjusted odds ratio, 1.8 for fever lasting > or = 24 hours) were not associated with urine testing but were associated with a UTI. Bacteremia accompanied the UTI in 10% of the patients, including 17% of those younger than 1 month. Among 807 infants not initially tested or treated with antibiotics, only 2 had a subsequent documented UTI; both did well. Practitioners order urine tests selectively, focusing on younger and more ill-appearing infants and on those without an apparent fever source. Such selective urine testing, with close follow-up, was associated with few late UTIs in this large study. Urine testing should focus particularly on uncircumcised boys, girls, the youngest and sickest infants, and those with persistent fever.

  3. Measurement of organically bound tritium in urine and feces

    International Nuclear Information System (INIS)

    Trivedi, A.; Duong, T.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    A bioassay method was developed for directly measuring organically bound tritium (OBT) in urine and feces. Samples first undergo low-temperature distillation and vacuum separation to isolate tritiated water (HTO) and exchangeable tritium. This is followed by converting the non-exchangeable tritium (i.e., OBT) into HTO through oxygen combustion. The method was investigated to: optimise the sample preparation procedures; establish OBT recovery (64% ± 7% for urine and 71% ± 8% for feces); and, determine the detection limit for OBT in urine (0.3 Bq · g -1 ) and feces (5 Bq · g -1 ). The method was evaluated for error sources that are associated with the exchange between HTO and OBT. It is concluded that this bioassay method can reliably measure OBT in urine and feces within the range of ± 10%

  4. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  5. Bilirubin in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Bilirubin (Urine); 86–87 p. Lab ...

  6. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  7. Isolation and identification of two galangin metabolites from rat urine ...

    African Journals Online (AJOL)

    Isolation and identification of two galangin metabolites from rat urine and determination of their in vitro hypolipidemic activity. Xuguang Zhang, Shouqian Cheng, Hailong Li, Xiaopo Zhang, Feng Chen, Youbin Li, Junqing Zhang, Yinfeng Tan ...

  8. Urine pretreatment for waste water processing systems. [for space station

    Science.gov (United States)

    Winkler, H. E.; Verostko, C. E.; Dehner, G. F.

    1983-01-01

    Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

  9. European guidelines for workplace drug testing in urine.

    Science.gov (United States)

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Mest en urine: van afval naar waardevol product

    NARCIS (Netherlands)

    Bos, A.P.; Cornelissen, J.M.R.; Groot Koerkamp, P.W.G.

    2010-01-01

    Het gescheiden houden van mest en urine in de veehouderij belooft een reeks positieve effecten te geven, waarmee de veehouderij én de akkerbouw een duurzaamheidssprong kunnen maken. Maar dat lukt alleen als er veel praktijken tegelijkertijd veranderen.

  11. The effects of gliadin on urine metabolome in mice

    DEFF Research Database (Denmark)

    Roager, Henrik Munch; Zhang, Li; Frandsen, Henrik Lauritz

    Gliadin, a proline-rich protein of gluten, is thought to modulate the gut microbiota and affect the intestinal permeability and immune system. However, little is known about the long-term effects of gliadin on the host and microbial metabolism. To study this, we compared the urine metabolome of two...... groups of mice, which were on a high fat diet with and without gliadin, respectively, for 23 weeks. Using liquid chromatography mass-spectrometry (MS) followed by multivariate analyses we were able to show a clear separation of the two groups of mice based on their urine metabolome. Discriminating...... in the gliadin mice. Also, Maillard reaction products and β-oxidized tocopherols were observed in higher levels in the urine of gliadin mice, suggesting increased oxidative stress in the gliadin mice. Indisputably, gliadin affected the urine metabolome. However, the mechanisms behind the observed metabolite...

  12. Mucus in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... is normal. An excess amount may indicate a urinary tract infection (UTI) or other medical condition. A test called urinalysis ... your urinalysis if you have symptoms of a UTI. These include: Frequent urge to urinate, but little ...

  13. Changes in the Optical Properties of Simulated Shuttle Waste Water Deposits- Urine Darkening

    Science.gov (United States)

    Albyn, Keith; Edwards, David; Alred, John

    2004-01-01

    Manned spacecraft have historically dumped the crew generated waste waster overboard, into the environment in which the spacecraft operates, sometimes depositing the waste water on the external spacecraft surfaces. The change in optical properties of wastewater deposited on spacecraft external surfaces, from exposure to space environmental effects, is not well understood. This study used nonvolatile residue (NVR) from Human Urine to simulate wastewater deposits and documents the changes in the optical properties of the NVR deposits after exposure to ultra violet (UV) radiation. Twenty NVR samples of, 0-angstromes/sq cm to 1000-angstromes/sq cm, and one sample contaminated with 1 to 2-mg/sq cm were exposed to UV radiation over the course of approximately 6151 equivalent sun hours (ESH). Random changes in sample mass, NVR, solar absorbance, and infrared emission were observed during the study. Significant changes in the UV transmittance were observed for one sample contaminated at the mg/sq cm level.

  14. Changes in the Optical Properties of Simulated Shuttle Waste Water Deposits: Urine Darkening

    Science.gov (United States)

    Albyn, Keith; Edwards, David; Alred, John

    2003-01-01

    Manned spacecraft have historically dumped the crew generated waste water overboard, into the environment in which the spacecraft operates, sometimes depositing the waste water on the external spacecraft surfaces. The change in optical properties of wastewater deposited on spacecraft external surfaces, from exposure to space environmental effects, is not well understood. This study used nonvolatile residue (NVR) from Human Urine to simulate wastewater deposits and documents the changes in the optical properties of the NVR deposits after exposure to ultra violet(UV)radiation. Twenty four NVR samples of, 0-angstromes/sq cm to 1000-angstromes/sq cm, and one sample contaminated with 1 to 2-mg/sq cm were exposed to UV radiation over the course of approximately 6151 equivalent sun hours (ESH). Random changes in sample mass, NVR, solar absorbance, and infrared emission were observed during the study. Significant changes in the UV transmittance were observed for one sample contaminated at the mg/sq cm level.

  15. Surface glycosylation profiles of urine extracellular vesicles.

    Directory of Open Access Journals (Sweden)

    Jared Q Gerlach

    Full Text Available Urinary extracellular vesicles (uEVs are released by cells throughout the nephron and contain biomolecules from their cells of origin. Although uEV-associated proteins and RNA have been studied in detail, little information exists regarding uEV glycosylation characteristics. Surface glycosylation profiling by flow cytometry and lectin microarray was applied to uEVs enriched from urine of healthy adults by ultracentrifugation and centrifugal filtration. The carbohydrate specificity of lectin microarray profiles was confirmed by competitive sugar inhibition and carbohydrate-specific enzyme hydrolysis. Glycosylation profiles of uEVs and purified Tamm Horsfall protein were compared. In both flow cytometry and lectin microarray assays, uEVs demonstrated surface binding, at low to moderate intensities, of a broad range of lectins whether prepared by ultracentrifugation or centrifugal filtration. In general, ultracentrifugation-prepared uEVs demonstrated higher lectin binding intensities than centrifugal filtration-prepared uEVs consistent with lesser amounts of co-purified non-vesicular proteins. The surface glycosylation profiles of uEVs showed little inter-individual variation and were distinct from those of Tamm Horsfall protein, which bound a limited number of lectins. In a pilot study, lectin microarray was used to compare uEVs from individuals with autosomal dominant polycystic kidney disease to those of age-matched controls. The lectin microarray profiles of polycystic kidney disease and healthy uEVs showed differences in binding intensity of 6/43 lectins. Our results reveal a complex surface glycosylation profile of uEVs that is accessible to lectin-based analysis following multiple uEV enrichment techniques, is distinct from co-purified Tamm Horsfall protein and may demonstrate disease-specific modifications.

  16. Estimating population salt intake in India using spot urine samples.

    Science.gov (United States)

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  17. Sample handling for mass spectrometric proteomic investigations of human urine.

    Science.gov (United States)

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Direct measurement of tritium in urine by liquid scintillation method

    International Nuclear Information System (INIS)

    Zhang Caihong; Wen Qinghua; Chen Kefei; Li Huaixin

    1999-01-01

    The author introduces the method for direct measurement of tritium concentration in urine using liquid scintillation. Effects of sampling containers, store patterns and storage time are studied. Meanwhile, results of two methods are compared with direct measurement method and oxidation distillation method. The results shows that direct measurement method is a economic and simple method, which can meet the need of determination of urine tritium for NPP workers. There is no significant difference compared with the data obtained by oxidation distillation method

  19. Stability studies of amphetamine and ephedrine derivatives in urine.

    Science.gov (United States)

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  20. Is specific gravity a good estimate of urine osmolality?

    Science.gov (United States)

    Imran, Sethi; Eva, Goldwater; Christopher, Shutty; Flynn, Ethan; Henner, David

    2010-01-01

    Urine specific gravity (USG) is often used by clinicians to estimate urine osmolality. USG is measured either by refractometry or by reagent strip. We studied the correlation of USG obtained by either method with a concurrently obtained osmolality. Using our laboratory's records, we retrospectively gathered data on 504 urine specimens on patients on whom a simultaneously drawn USG and an osmolality were available. Out of these, 253 USG's were measured by automated refractometry and 251 USG's were measured by reagent strip. Urinalysis data on these subjects were used to determine the correlation between USG and osmolality, adjusting for other variables that may impact the relationship. The other variables considered were pH, protein, glucose, ketones, nitrates, bilirubin, urobilinogen, hemoglobin, and leukocyte esterase. The relationships were analyzed by linear regression. This study demonstrated that USG obtained by both reagent strip and refractometry had a correlation of approximately 0.75 with urine osmolality. The variables affecting the correlation included pH, ketones, bilirubin, urobilinogen, glucose, and protein for the reagent strip and ketones, bilirubin, and hemoglobin for the refractometry method. At a pH of 7 and with an USG of 1.010 predicted osmolality is approximately 300  mosm/kg/H(2)O for either method. For an increase in SG of 0.010, predicted osmolality increases by 182  mosm/kg/H(2) O for the reagent strip and 203  mosm/kg/H(2)O for refractometry. Pathological urines had significantly poorer correlation between USG and osmolality than "clean" urines. In pathological urines, direct measurement of urine osmolality should be used. © 2010 Wiley-Liss, Inc.

  1. Study about excretion of 210 Po in urine

    International Nuclear Information System (INIS)

    Fonseca Azeredo, A.M.G. da.

    1988-01-01

    The urine of mines's workers are analysed to detect the presence of 210 Po. The results was compared with the workers and with a control population. Cigarettes samples was analysed two and confirmed the 210 presence. The control population individuals were divided in smokers and non smokers and them urine was investigated the influence of the smoke in the 210 Po excretion. (L.M.J.)

  2. Uranium internal exposure evaluation based on urine assay data

    International Nuclear Information System (INIS)

    Lawrence, J.N.P.

    1984-09-01

    The difficulties in assessing internal exposures to uranium from urine assay data are described. A simplified application of the ICRP-30 and ICRP Lung Model concepts to the estimation of uranium intake is presented. A discussion follows on the development of a computer code utilizing the ICRP-30-based uranium elimination model with the existing urine assay information. The calculated uranium exposures from 1949 through 1983 are discussed. 13 references, 1 table

  3. Comparison of Urine and Oral Fluid for Workplace Drug Testing.

    Science.gov (United States)

    Casolin, Armand

    2016-09-01

    To determine the relative detection rates of urine versus oral fluid testing in a safety sensitive industry and the correlation with diagnosed substance use disorders and possible impairment at work. The trial involved 1,500 paired urine and oral fluid tests performed in accordance with Australian Standard/New Zealand Standard (AS/NZS) 4308:2008 and AS 4760:2006. Workers who returned a positive test were screened for substance use disorders, as defined by DSM-5, and for possible impairment at work following that particular episode of substance use. Substances were detected in 3.7% (n = 56) of urine samples and 0.5% (n = 8) of oral fluid samples (p < 0.0001). One worker (0.07%) had a substance detected on oral fluid alone versus 49 workers (3.3%) who had substances detected on urine alone. Twelve workers returned a positive result, defined as being consistent with the use of an illicit drug or a controlled substance without a clinical indication and prescription. Nine workers tested positive on urine alone, one on oral fluid alone and two on both (p = 0.0114). Of note, 6/11 workers who tested positive on urine had possible impairment at work and 2/11 had a substance use disorder versus 2/3 and 0/3, respectively, who tested positive on oral fluid. Urine drug testing performed in accordance with AS/NZS 4308:2008 is more likely to detect overall substance use and illicit drug use than oral fluid testing conducted in accordance with AS 4760:2006. Urine testing performed in accordance with AS/NZS 4308:2008 may also be more likely to detect workers with possible impairment at work and substance use disorders than oral fluid testing performed in accordance with AS 4760:2006. © The Author 2016. Published by Oxford University Press.

  4. Analysis of uranium in urine of persons occupationaly exposed

    International Nuclear Information System (INIS)

    Nunes, S.C.

    1985-01-01

    A technique of uranium analysis in urine of persons occupationaly exposed, using the fluorimetric method is proposed. Two procedures for the determination are presented: the first employs platinum dishes, obtaining a detection limit of 1 ppb and the second one, using aluminium dishes, shows a detection limit of 100 ppb. Uranium and urine physico-chemical characteristics are described, as well as norms for the exposition of workers to uranium. (M.A.C.) [pt

  5. Fluorimetric routine determination of uranium in urine samples

    International Nuclear Information System (INIS)

    Widua, L.; Schieferdecker, H.; Hezel, U.

    With a modified RA 2 reflectance accessory for the Zeiss PMQII/PMQ3 spectrophotometer, uranium in urine was detected with higher sensitivity. A quick method is now available with a detection limit of <2 μg U/1 urine for the determination of possible uranium incorporations, whose sensitivity meets the requirements of radiation protection. Compared with other extraction methods, the instrument outlay and the required working time are small. The total error of the method is below 5 percent

  6. Urine Culture in Uncomplicated UTI: Interpretation and Significance.

    Science.gov (United States)

    Stapleton, Ann E

    2016-05-01

    Acute uncomplicated urinary tract infection (UTI) is a common clinical problem, accounting for millions of outpatient visits in the USA annually. Although routinely obtaining urine cultures in UTI is not recommended, there are circumstances in which obtaining a pre-therapy culture may be warranted or chosen by clinicians, such as when indicated by the need for careful antimicrobial stewardship. This review focuses on understanding reasons for obtaining a pre-therapy culture, methods of collection, and appropriately interpreting urine culture data.

  7. Pesticide residues in birds and mammals

    Science.gov (United States)

    Stickel, L.F.; Edwards, C.A.

    1973-01-01

    SUMMARY: Residues of organochlorine pesticides and their breakdown products are present in the tissues of essentially all wild birds throughout the world. These chemicals accumulate in fat from a relatively small environmental exposure. DDE and dieldrin are most prevalent. Others, such as heptachlor epoxide, chlordane, endrin, and benzene hexachloride also occur, the quantities and kinds generally reflecting local or regional use. Accumulation may be sufficient to kill animals following applications for pest control. This has occurred in several large-scale programmes in the United States. Mortality has also resulted from unintentional leakage of chemical from commercial establishments. Residues may persist in the environment for many years, exposing successive generations of animals. In general, birds that eat other birds, or fish, have higher residues than those that eat seeds and vegetation. The kinetic processes of absorption, metabolism, storage, and output differ according to both kind of chemical and species of animal. When exposure is low and continuous, a balance between intake and excretion may be achieved. Residues reach a balance at an approximate animal body equilibrium or plateau; the storage is generally proportional to dose. Experiments with chickens show that dieldrin and heptachlor epoxide have the greatest propensity for storage, endrin next, then DDT, then lindane. The storage of DDT was complicated by its metabolism to DDE and DDD, but other studies show that DDE has a much greater propensity for storage than either DDD or DDT. Methoxychlor has little cumulative capacity in birds. Residues in eggs reflect and parallel those in the parent bird during accumulation, equilibrium, and decline when dosage is discontinued. Residues with the greatest propensity for storage are also lost most slowly. Rate of loss of residues can be modified by dietary components and is speeded by weight loss of the animal. Under sublethal conditions of continuous

  8. Transporting large volumes of residual radioactive material: FUSRAP solutions

    International Nuclear Information System (INIS)

    Pressnell, T.; McDaniel, P.; Darby, J.

    1997-01-01

    During the 1940s, 1950s and 1960s, many sites in the United States were used by the Manhattan Engineer District and the Atomic Energy Commission for processing and storing uranium and thorium ores and metals. Some of the sites were owned by the federal government; others were owned by universities or other institutions; and still others, such as chemical plants, were privately owned. The Formerly Utilized Sites Remedial Action Program (FUSRAP) is one of several U.S. Department of Energy programs created to address radioactive contamination in excess of guidelines at these sites. FUSRAP currently includes 46 sites in 14 states. This article includes the following topics in describing FUSRAP work: Logistics challenges; engineering challenges (package inspection, equipment compatability, moisture content requirements, waste volume estimation); Traffic management

  9. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  10. Quantitation of products from riboflavin in rat urine

    International Nuclear Information System (INIS)

    Chastain, J.L.; McCormick, D.B.

    1986-01-01

    When [2- 14 C] riboflavin is injected i.p. into rats, the excreted vitamin in urine and feces has been shown to be the intact vitamin with trace amounts of lumichrome and lumiflavin. Recent findings with 14 C-riboflavin fed to rats indicated higher levels of riboflavin catabolites in urine, e.g., 7- and 8-carboxylumichromes. The authors have determined catabolites in urine from male rats fed 0, 2, and 6 μg riboflavin/g diet/day for six weeks. Two rats from each group were placed weekly in metabolic cages, and urine was collected for 24 hours. On the fourth week, a third animal from each group received an i.p. injection of 14 C-riboflavin and the urine was collected for 48 hours. Urine samples were extracted with phenol for flavin components and with chloroform for derivatives of lumichrome and lumiflavin. Riboflavin was the predominant flavin excreted by all diet groups with trace amounts of coenzymes and 7- and 8-hydroxymethylriboflavin. Riboflavin accounted for 85% of all the radioactivity recovered from the deficient and sufficient rats and 90% in rats fed excess. Lumichrome-type compounds including carboxylumichromes accounted for only a few % of recovered radioactivity. Thus, these components are primarily a product of intestinal microfloral degradation rather than significant tissue catabolites of riboflavin

  11. Comparison of urine analysis using manual and sedimentation methods.

    Science.gov (United States)

    Kurup, R; Leich, M

    2012-06-01

    Microscopic examination of urine sediment is an essential part in the evaluation of renal and urinary tract diseases. Traditionally, urine sediments are assessed by microscopic examination of centrifuged urine. However the current method used by the Georgetown Public Hospital Corporation Medical Laboratory involves uncentrifuged urine. To encourage high level of care, the results provided to the physician must be accurate and reliable for proper diagnosis. The aim of this study is to determine whether the centrifuge method is more clinically significant than the uncentrifuged method. In this study, a comparison between the results obtained from centrifuged and uncentrifuged methods were performed. A total of 167 urine samples were randomly collected and analysed during the period April-May 2010 at the Medical Laboratory, Georgetown Public Hospital Corporation. The urine samples were first analysed microscopically by the uncentrifuged, and then by the centrifuged method. The results obtained from both methods were recorded in a log book. These results were then entered into a database created in Microsoft Excel, and analysed for differences and similarities using this application. Analysis was further done in SPSS software to compare the results using Pearson ' correlation. When compared using Pearson's correlation coefficient analysis, both methods showed a good correlation between urinary sediments with the exception of white bloods cells. The centrifuged method had a slightly higher identification rate for all of the parameters. There is substantial agreement between the centrifuged and uncentrifuged methods. However the uncentrifuged method provides for a rapid turnaround time.

  12. The residue of trenbolone from male Garut sheep which implanted by trenbolone acetate

    Directory of Open Access Journals (Sweden)

    R Widiastuti

    2001-10-01

    Full Text Available Trenbolone acetate (TBA is a growth hormone promoter which is implanted into animal to increase the body weight. The implantation of TBA in animal may cause the occurrence of residues of TBA and its metabolite (17-β-trenbolone. The presence of the residue might threat to human health. The aim of this research work was to study the presence of the residue of trenbolone in male Garut sheep which is implanted by TBA. The sheep were divided into 2 groups, those were D1 which were implanted by 40 mg TBA and D2 which were implanted by 60 mg TBA. One animal each from D1 and D2 were killed in the week 1, 2, 3 and 4 after implantation. And 24 hours before slaughtering the urine of D1 and D2 were collected using the metabolism cages. The samples for residue analysis were the organs such as liver, kidney, and the muscles around the implantation sites i.e inner and outer, upper front leg and upper back leg. The samples were extracted by organic solvents and analysed by HPLC. The residue of trenbolone occured in all samples of D1 and D2 which killed on 1 and 2 weeks after implantation. The residues occured on those which were killed 3 weeks after implantation were only in inner and outer samples. The residues in meat and organs were not detected in D1 nor D2 which were killed 4 weeks after implantation. The residue of trenbolone was also detected in the urine and still were detected in D1 and D2 which implanted by TBA for 4 weeks.

  13. Decomposition of rice residue in tropical soils, 2

    International Nuclear Information System (INIS)

    Yoneyama, Tadakatsu; Yoshida, Tomio

    1977-01-01

    The decomposition processes of intact rice residue (leaf blades) in the Maahas soil in the Philippines were investigated. Three sets of beakers simulating both lowland and upland conditions were incubated in the dark at 30 deg. C. One set of beakers had neither rice residue nor fertilizer. Pieces of leaf blades weighing 204 mg (dry weight) were inserted in the second set. Pieces of leaf blades were inserted in the third set, and 200 ppm of fertilizer nitrogen as 15 N-labelled ammonium sulfate was added. The experiment dealt with the nitrogen immobilization by rice residue under lowland and upland conditions. The rice residue which has contained low nitrogen absorbed nitrogen from the soil and from the added fertilizer (ammonium sulfate) during its decomposition under both conditions. Under the lowland condition, the amount of nitrogen immobilized was small during the first week, but became large after 2 or 3 weeks. Under the upland condition, the immobilized nitrogen reached its maximum during the first week, but the amount was not so large as that under the lowland condition. The added fertilizer stimulated the decrease of weight of the rice residue in the early incubation period, but retarded it later under both conditions. The absorption of fertilizer by the rice residue ceased at the early stage of residue decomposition, but the nitrogen content of the residue continued to increase. (Iwakiri, K.)

  14. Determining the authenticity of athlete urine in doping control by DNA analysis.

    Science.gov (United States)

    Devesse, Laurence; Syndercombe Court, Denise; Cowan, David

    2015-10-01

    The integrity of urine samples collected from athletes for doping control is essential. The authenticity of samples may be contested, leading to the need for a robust sample identification method. DNA typing using short tandem repeats (STR) can be used for identification purposes, but its application to cellular DNA in urine has so far been limited. Here, a reliable and accurate method is reported for the successful identification of urine samples, using reduced final extraction volumes and the STR multiplex kit, Promega® PowerPlex ESI 17, with capillary electrophoretic characterisation of the alleles. Full DNA profiles were obtained for all samples (n = 20) stored for less than 2 days at 4 °C. The effect of different storage conditions on yield of cellular DNA and probability of obtaining a full profile were also investigated. Storage for 21 days at 4 °C resulted in allelic drop-out in some samples, but the random match probabilities obtained demonstrate the high power of discrimination achieved through targeting a large number of STRs. The best solution for long-term storage was centrifugation and removal of supernatant prior to freezing at -20 °C. The method is robust enough for incorporation into current anti-doping protocols, and was successfully applied to 44 athlete samples for anti-doping testing with 100% concordant typing. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Magnetic graphene oxide as adsorbent for the determination of polycyclic aromatic hydrocarbon metabolites in human urine.

    Science.gov (United States)

    Zhu, Linli; Xu, Hui

    2014-09-01

    Detection of monohydroxy polycyclic aromatic hydrocarbons metabolites in urine is an advisable and valid method to assess human environmental exposure to polycyclic aromatic hydrocarbons. In this work, novel Fe3O4/graphene oxide composites were prepared and their application in the magnetic solid-phase extraction of monohydroxy polycyclic aromatic hydrocarbons in urine was investigated by coupling with liquid chromatography and mass spectrometry. In the hybrid material, superparamagnetic Fe3O4 nanoparticles provide fast separation to simplify the analytical process and graphene oxide provides a large functional surface for the adsorption. The prepared magnetic nanocomposites were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, and vibrating sample magnetometry. The experimental conditions were optimized systematically. Under the optimal conditions, the recoveries of these compounds were in the range of 98.3-125.2%, the relative standard deviations ranged between 6.8 and 15.5%, and the limits of detection were in the range of 0.01-0.15 ng/mL. The simple, quick, and affordable method was successfully used in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities. The results indicated that the monohydroxy polycyclic aromatic hydrocarbons level in human urine can provide useful information for environmental exposure to polycyclic aromatic hydrocarbons. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Quality Control Samples for the Radiological Determination of Tritium in Urine Samples

    International Nuclear Information System (INIS)

    Ost'pezuk, P.; Froning, M.; Laumen, S.; Richert, I.; Hill, P.

    2004-01-01

    The radioactive decay product of tritium is a low energy beta that cannot penetrate the outer dead layer of human skin. Therefore , the main hazard associated with tritium is internal exposure. In addition, due to the relatively long half life and short biological half life, tritium must be ingested in large amounts to pose a significant health risk. On the other hand, the internal exposure should be kept as low as practical. For incorporation monitoring of professional radiation workers the quality control is of utmost importance. In the Research Centre Juelich GmbH (FZJ) a considerable fraction of monitoring by excretion analysis relates to the isotope Tritium. Usually an aliquot of an urine sample is mixed with a liquid scintillator and measured in a liquid scintillation counter. Quality control samples in the form of three kind of internal reference samples (blank, reference samples with low activity and reference sample with elevated activity) were prepared from a mixed, Tritium (free) urine samples. 1 ml of these samples were pipetted into a liquid scintillation vial. In the part of theses vials a known amounts of Tritium were added. All these samples were stored at 20 degrees. Based on long term use of all these reference samples it was possible to construct appropriate control charts with the upper and lower alarm limits. Daily use of these reference samples decrease significantly the risk for false results in original urine with no significant increase of the determination time. (Author) 2 refs

  17. Halogenated Anesthetics Determination in Urine by SPME/GC/MS and Urine Levels Relationship Evaluation with Surgical Theatres Contamination

    Directory of Open Access Journals (Sweden)

    Serena Indelicato

    2014-01-01

    Full Text Available In this work, a new sensitive analytical method has been developed and evaluated for the determination of the most commonly used gaseous anesthetics, desflurane, sevoflurane, and this latter’s hepatic metabolite hexafluoroisopropanol (HFIP in the urine. In addition, an evaluation of anesthetics exposition on the urine levels of a small population of surgical operators has been performed and results are briefly discussed.

  18. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    Science.gov (United States)

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and

  19. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    OpenAIRE

    ?nce, Fatma Demet; Ellida?, Hamit Ya?ar; Koseo?lu, Mehmet; ?im?ek, Ne?e; Yal??n, H?lya; Zengin, Mustafa Osman

    2016-01-01

    Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA), Dirui...

  20. Agreement of pesticide biomarkers between morning void and 24-h urine samples from farmers and their children.

    Science.gov (United States)

    Scher, Deanna P; Alexander, Bruce H; Adgate, John L; Eberly, Lynn E; Mandel, Jack S; Acquavella, John F; Bartels, Michael J; Brzak, Kathy A

    2007-07-01

    In pesticide biomonitoring studies, researchers typically collect either single voids or daily (24-h) urine samples. Collection of 24-h urine samples is considered the "gold-standard", but this method places a high burden on study volunteers, requires greater resources, and may result in misclassification of exposure or underestimation of dose due to noncompliance with urine collection protocols. To evaluate the potential measurement error introduced by single void samples, we present an analysis of exposure and dose for two commonly used pesticides based on single morning void (MV) and 24-h urine collections in farmers and farm children. The agreement between the MV concentration and its corresponding 24-h concentration was analyzed using simple graphical and statistical techniques and risk assessment methodology. A consistent bias towards overprediction of pesticide concentration was found among the MVs, likely in large part due to the pharmacokinetic time course of the analytes in urine. These results suggest that the use of single voids can either over- or under-estimate daily exposure if recent pesticide applications have occurred. This held true for both farmers as well as farm children, who were not directly exposed to the applications. As a result, single void samples influenced the number of children exposed to chlorpyrifos whose daily dose estimates were above levels of toxicologic significance. In populations where fluctuations in pesticide exposure are expected (e.g., farm families), the pharmacokinetics of the pesticide and the timing of exposure events and urine collection must be understood when relying on single voids as a surrogate for longer time-frames of exposure.

  1. Immobilization of acid digestion residue

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.; Allen, C.R.

    1983-01-01

    Acid digestion treatment of nuclear waste is similar to incineration processes and results in the bulk of the waste being reduced in volume and weight to some residual solids termed residue. The residue is composed of various dispersible solid materials and typically contains the resultant radioactivity from the waste. This report describes the immobilization of the residue in portland cement, borosilicate glass, and some other waste forms. Diagrams showing the cement and glass virtification parameters are included in the report as well as process steps and candidate waste product forms. Cement immobilization is simplest and probably least expensive; glass vitrification exhibits the best overall volume reduction ratio

  2. Formulation of morning product using food residues

    Directory of Open Access Journals (Sweden)

    Maria do Rosário de Fátima Padilha

    2017-09-01

    Full Text Available In Brazil, there is resistance of the population to the use of stalks, leaves, peels and seeds of vegetables and fruits, leading to trash important parts of the food in good physiological conditions and with the presence of potential nutrients. In this research, a morning product was elaborated using green and dry coconut residue, jerimum and melon seed, crystallized sicilian lemon peel, cashew nut, common rapadura sweet and ginger. The bacteriological tests proved the hygienic-sanitary quality of the product, therefore suitable for consumption, that is, according to RDC 12/2001. It was also observed that the dehydration of all the residues reached the legal levels and accepted by ANVISA that limits in 25% the water content in the dehydrated foods. As for the centesimal composition, it was observed that the elaborated product with residues and other ingredients had a good content of macro nutrients. A use of the type of waste as a new food proposal constitutes an alternative to avoid and reduce: the serious environmental problem caused by the large residual volume generated, and the inadequate places in which they are stored or deposited, aggravating the scenario of food-borne pollutants.

  3. Residual Stress Testing of Outer 3013 Containers

    International Nuclear Information System (INIS)

    Dunn, K.

    2004-01-01

    A Gas Tungsten Arc Welded (GTAW) outer 3013 container and a laser welded outer 3013 container have been tested for residual stresses according to the American Society for Testing Materials (ASTM) Standard G-36-94 [1]. This ASTM standard describes a procedure for conducting stress-corrosion cracking tests in boiling magnesium chloride (MgCl2) solution. Container sections in both the as-fabricated condition as well as the closure welded condition were evaluated. Significantly large residual stresses were observed in the bottom half of the as-fabricated container, a result of the base to can fabrication weld because through wall cracks were observed perpendicular to the weld. This observation indicates that regardless of the closure weld technique, sufficient residual stresses exist in the as-fabricated container to provide the stress necessary for stress corrosion cracking of the container, at the base fabrication weld. Additionally, sufficiently high residual stresses were observed in both the lid and the body of the GTAW as well as the laser closure welded containers. The stresses are oriented perpendicular to the closure weld in both the container lid and the container body. Although the boiling MgCl2 test is not a quantitative test, a comparison of the test results from the closure welds shows that there are noticeably more through wall cracks in the laser closure welded container than in the GTAW closure welded container

  4. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures being the precision in recognizing contacts and the difference between the distribution of distances in the subset of predicted contact pairs versus all pairs of residues in the structure. The emphasis is placed on the prediction of long-range contacts (i.e., contacts between residues separated by at least 24 residues along sequence) in target proteins that cannot be easily modeled by homology. Although there is considerable activity in the field, the current analysis reports no discernable progress since CASP8.

  5. Development of Personalized Urination Recognition Technology Using Smart Bands

    Directory of Open Access Journals (Sweden)

    Sung-Jong Eun

    2017-04-01

    Full Text Available Purpose This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. Methods This study aimed to develop an algorithm that recognizes urination based on a patient’s posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. Results An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. Conclusions The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.

  6. Biophysical effects of water and synthetic urine on skin.

    Science.gov (United States)

    Mayrovitz, H N; Sims, N

    2001-01-01

    Pressure ulcers often occur at sites subjected to pressure and wetness. Although skin wetness is a risk factor for pressure ulcers,the mechanisms and effects of wetness versus urine constituents on skin breakdown is unclear. The hypothesis that wetness reduces skin hardness and, thereby, increases vulnerability of underlying blood vessels to pressure-induced flow reductions was tested in this study. Pads saturated with water and with a water solution mixed with the main chemical constituents of urine (synthetic urine; s-urine) were applied to forearm skin of 10 healthy subjects for 5.5 hours. Skin hardness, blood flow change caused by 60 mm Hg of pressure, erythema, and temperature were compared among dry, water, and s-urine test sites. 10 healthy women. Research Center, Nova Southeastern University, Health Professions Division, Fort Lauderdale, FL. S-urine and water caused significant reductions in initial hardness and caused greater initial perfusion decreases during pressure load when compared with dry sites. Skin temperature and erythema were lower at wet sites when compared with dry sites. The findings of this study are consistent with the concept that sustained skin wetness increases vulnerability to pressure-induced blood flow reduction. The effect appears to be mainly dependent on wetness, but urine constituents may exacerbate the effect. In addition, wetness-related skin cooling may play a role. In the healthy subjects studied, the blood flow decrease was not sustained due to perfusion recovery under pressure. Skin wetness would likely have more sustained effects in patients with compromised recovery mechanisms. Measures to diminish skin exposure to wetness in these patients, whatever the wetness source, are an important consideration in a multifaceted strategy to reduce the risk of pressure ulcers.

  7. [Estimation of mercury in the urine of cigarette smokers].

    Science.gov (United States)

    Kulikowska-Karpińska, Elżbieta; Zdanowicz, Magdalena; Gałażyn-Sidorczuk, Małgorzata

    Cigarette smoking is one of the most common habits of the modern world. According to a NATPOL PLU study, every third adult Pole is dependent on nicotine. Tobacco smoke contains about 5,000 components, of which over 1,000 are very toxic chemical substances (3,4-benzopyrene, heavy metals, free radicals, hydrogen cyanide, nitrogen oxides and N-nitrosamines). Exposure to tobacco smoke is an example of a complex, with a significant number of interactions. To assess the concentration of copper in the urine of smokers. Based on the results, an attempt was made to determine whether smoking can affect the level of copper in the body. The study involved 170 healthy volunteers, 99 smokers and 71 non-smokers (control group). The age of patients in both groups were in the range of 20-60 years. The mean age for men and women was 41 years. The average length of cigarette smoking was 18 years for women and 21 years for men, and the number of cigarettes smoked 1-40 ⁄ 24. The urine concentrations of Cu were determined by atomic absorption spectrometry (AAS) and serum creatinine kinetic method using a set of BIOLAB. Cu concentration in urine was expressed in mg / g creatinine. Smokers were found to have reduced levels of copper in the urine, depending on sex, age and brand of cigarettes. In male smokers, copper concentration in the urine was dependent on age and time of smoking, whereas among women this relationship was not observed. Cigarette smoking significantly influences the level of copper in the urine. Both female and male smokers showed reduced levels of copper in the urine, which may indicate its increased accumulation in the body. Excessive accumulation of copper is very dangerous since it may exhibit toxic effects towards many organs and systems.

  8. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    Science.gov (United States)

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  9. Mining the human urine proteome for monitoring renal transplant injury

    Energy Technology Data Exchange (ETDEWEB)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang; Wang, Anyou; Nicora, Carrie D.; Fillmore, Thomas L.; Shi, Tujin; Webb-Robertson, Bobbie-Jo; Smith, Richard D.; Qian, Wei-Jun; Salvatierra, Oscar; Camp, David G.; Sarwal, Minnie M.

    2016-06-01

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

  10. Acephate and buprofezin residues in olives and olive oil.

    Science.gov (United States)

    Cabras, P; Angioni, A; Garau, V L; Pirisi, F M; Cabitza, F; Pala, M

    2000-10-01

    Field trials were carried out to study the persistence of acephate and buprofezin on olives. Two cultivars, pizz'e carroga and pendolino, with very large and small fruits respectively were used. After treatment, no difference was found between the two pesticide deposits on the olives. The disappearance rates, calculated as pseudo first order kinetics, were similar for both pesticides (on average 12 days). Methamidophos, the acephate metabolite, was always present on all olives, and in some pendolino samples it showed higher residues than the maximum residue limit (MRL). During washing, the first step of olive processing, the residue level of both pesticides on the olives did not decrease. After processing of the olives into oil, no residues of acephate or methamidophos were found in the olive oil, while the residues of buprofezin were on average four times higher than on olives.

  11. Residual stress studies of austenitic and ferritic steels

    International Nuclear Information System (INIS)

    Chrenko, R.M.

    1978-01-01

    Residual studies have been made on austenitic and ferritic steels of the types used as structural materials. The residual stress results presented here will include residual stress measurements in the heat-affected zone on butt welded Type 304 stainless steel pipes, and the stresses induced in Type 304 austenitic stainless steel and Type A508 ferritic steel by several surface preparations. Such surface preparation procedures as machining and grinding can induce large directionality effects in the residual stresses determined by X-ray techniques and some typical data will be presented. A brief description is given of the mobile X-ray residual stress apparatus used to obtain most of the data in these studies. (author)

  12. Biodrying of animal slaughterhouse residues and heat production

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, Y. [Centre de recherche industrielle, Quebec City, PQ (Canada)

    2010-07-01

    Animal carcasses from slaughterhouses are usually composted on farms, but the composting process is not optimized and a large volumes of carbonaceous residues are needed. This type of composting takes place over a period of 6 to 9 months in a nonaerated static pile. Quebec's industrial research centre (CRIQ) developed an organic biodrying process (BIOSECO) adapted to large-scale operations in order to optimize the treatment of slaughterhouse residues. Biodrying is a form of composting, in which the thermophilic phase is optimized, making it possible to evaporate large amounts of water. Biodrying is done inside a building and reduces the amount of carbonaceous residues considerably. The process is optimized by the sequence in which the slaughterhouse residues are added, the choice of input and the aeration flow. Slaughterhouse residues can be treated non-stop throughout the entire year. Since the odours are nearly completed limited to the building, the biodrying can be done near the slaughterhouse. A large amount of heat was produced by the process during the pilot project. It was concluded that the BIOSECO biodrying process is suitable for treating slaughterhouse residues in an effective and economic manner, and has the added advantage of producing heat that could be used for various purposes.

  13. Reactivity of Athabasca residue and of its SARA fractions during residue hydroconversion

    Energy Technology Data Exchange (ETDEWEB)

    Verstraete, J.; Danial-Fortain, P.; Gauthier, T.; Merdrignac, I. [IFP-Lyon, Vermaison (France); Budzinski, H. [Bordeaux Univ. (France). ISM-LPTC, UMR CNRS

    2009-07-01

    Residue conversion processes are becoming increasingly important because of the declining market for residual fuel oil and a greater demand for middle distillates. Ebullated-bed hydroconversion is a commercially proven technology for converting heavy feedstocks with high amounts of impurities. The process enables the conversion of atmospheric or vacuum residues at temperatures up to 440 degrees C, and at liquid hourly space velocity (LHSV) conditions in the range of 0.15 to 0.5 per hour. A 540 degrees C conversion of up to 80 weight per cent can be achieved under these conditions. This paper reported on a research study conducted at IFP Lyon in which the residue hydroconversion in a large-scale ebullated bed bench unit was investigated to determine the impact of operating conditions and feed properties on yield and product qualities. Hydrogen was added to the feed in the bench units to keep a high hydrogen partial pressure and favour the catalytic hydroconversion reactions. In a typical test, the reactor was fed with 50 g of feedstock and 0.45 g of crushed equilibrium industrial NiMo catalyst, pressurized hydrogen and quickly heated at the reaction temperature. This paper also discussed the conversion of Athabasca bitumen residue in the large-scale pilot plant and also in the small scale batch reactor. The effect of operating temperature and space velocity was examined. The reactivity of the saturates, aromatics, resins and asphaltenes (SARA) fractions of the bitumen was studied separately in order to better understand the conversion mechanisms and reactivities. The Athabasca bitumen feed and SARA fractions were also analyzed in terms of standard petroleum analysis, SARA fractionation, elemental analysis, size exclusion chromatography (SEC) and 13C NMR. Hydroconversion experiments were conducted in the batch unit at different reaction temperatures and reaction times. A comparison of small-scale batch results with those obtained with the continuous large-scale bench

  14. Landfilling of waste incineration residues

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Astrup, Thomas; Cai, Zuansi

    2002-01-01

    Residues from waste incineration are bottom ashes and air-pollution-control (APC) residues including fly ashes. The leaching of heavy metals and salts from the ashes is substantial and a wide spectrum of leaching tests and corresponding criteria have been introduced to regulate the landfilling...

  15. Residual stress characterization of steel TIG welds by neutron diffraction and by residual magnetic stray field mappings

    Energy Technology Data Exchange (ETDEWEB)

    Stegemann, Robert, E-mail: Robert.Stegemann@bam.de [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); Cabeza, Sandra; Lyamkin, Viktor; Bruno, Giovanni; Pittner, Andreas [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); Wimpory, Robert; Boin, Mirko [HZB Helmholtz-Zentrum Berlin, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Kreutzbruck, Marc [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); IKT, University of Stuttgart, Pfaffenwaldring 32, 70569 Stuttgart (Germany)

    2017-03-15

    The residual stress distribution of tungsten inert gas welded S235JRC+C plates was determined by means of neutron diffraction (ND). Large longitudinal residual stresses with maxima around 600 MPa were found. With these results as reference, the evaluation of residual stress with high spatial resolution GMR (giant magneto resistance) sensors was discussed. The experiments performed indicate a correlation between changes in residual stresses (ND) and the normal component of local residual magnetic stray fields (GMR). Spatial variations in the magnetic field strength perpendicular to the welds are in the order of the magnetic field of the earth. - Highlights: • Comparison of magnetic microstructure with neutron diffraction stress analysis. • High spatial resolution magnetic stray field images of hypereutectoid TIG welds. • Spatial variations of the stray fields are below the magnetic field of the earth. • GMR spin valve gradiometer arrays adapted for the evaluation of magnetic microstructures. • Magnetic stray fields are closely linked to microstructure of the material.

  16. Mapping allostery through computational glycine scanning and correlation analysis of residue-residue contacts.

    Science.gov (United States)

    Johnson, Quentin R; Lindsay, Richard J; Nellas, Ricky B; Fernandez, Elias J; Shen, Tongye

    2015-02-24

    Understanding allosteric mechanisms is essential for the physical control of molecular switches and downstream cellular responses. However, it is difficult to decode essential allosteric motions in a high-throughput scheme. A general two-pronged approach to performing automatic data reduction of simulation trajectories is presented here. The first step involves coarse-graining and identifying the most dynamic residue-residue contacts. The second step is performing principal component analysis of these contacts and extracting the large-scale collective motions expressed via these residue-residue contacts. We demonstrated the method using a protein complex of nuclear receptors. Using atomistic modeling and simulation, we examined the protein complex and a set of 18 glycine point mutations of residues that constitute the binding pocket of the ligand effector. The important motions that are responsible for the allostery are reported. In contrast to conventional induced-fit and lock-and-key binding mechanisms, a novel "frustrated-fit" binding mechanism of RXR for allosteric control was revealed.

  17. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    Science.gov (United States)

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  18. Mass spectrometric characterisation of a condensation product between porphobilinogen and indolyl-3-acryloylglycine in urine of patients with acute intermittent porphyria.

    Science.gov (United States)

    Marcos, Josep; Ibañez, Maria; Ventura, Rosa; Segura, Jordi; To-Figueras, Jordi; Pozo, Oscar J

    2015-07-01

    We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl-3-acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG-IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at -20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG-IAG in samples collected from AIP patients. However, no correlation was found between PBG-IAG and IAG. Purified PBG-IAG did not form the characteristic chromogen after application of p-dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG-IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Detection and quantification of rituximab in the human urine.

    Science.gov (United States)

    Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario

    2017-12-01

    B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Reverse osmosis brine for phosphorus recovery from source separated urine.

    Science.gov (United States)

    Tian, Xiujun; Wang, Guotian; Guan, Detian; Li, Jiuyi; Wang, Aimin; Li, Jin; Yu, Zhe; Chen, Yong; Zhang, Zhongguo

    2016-12-01

    Phosphorus (P) recovery from waste streams has recently been recognized as a key step in the sustainable supply of this indispensable and non-renewable resource. The feasibility of using brine from a reverse osmosis (RO) membrane unit treating cooling water as a precipitant for P recovery from source separated urine was evaluated in the present study. P removal efficiency, process parameters and precipitate properties were investigated in batch and continuous flow experiments. More than 90% of P removal was obtained from both undiluted fresh and hydrolyzed urines by mixing with RO brine (1:1, v/v) at a pH over 9.0. Around 2.58 and 1.24 Kg of precipitates could be recovered from 1 m 3 hydrolyzed and fresh urine, respectively, and the precipitated solids contain 8.1-19.0% of P, 10.3-15.2% of Ca, 3.7-5.0% of Mg and 0.1-3.5% of ammonium nitrogen. Satisfactory P removal performance was also achieved in a continuous flow precipitation reactor with a hydraulic retention time of 3-6 h. RO brine could be considered as urinal and toilet flush water despite of a marginally higher precipitation tendency than tap water. This study provides a widely available, low - cost and efficient precipitant for P recovery in urban areas, which will make P recovery from urine more economically attractive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. The Recovery of Water and Nitrogen from Urine in BLSS

    Science.gov (United States)

    Xie, Beizhen; Liu, Hong; Deng, Shengda

    The recycle and reuse of the wastewater is one of the main factors for realizing a higher closure degree of bioregenerative life support system (BLSS), and the treatment and recovery of the crew’s urine are the most difficult and critical issues. Urine contains a lot of water and high concentrations of urea and salts. Water can be used for the irrigation of the plants in BLSS, and the nitrogen is also the necessary nutrient for plant growth. Therefore, if the nitrogen could be recycled simultaneously while desalting the urine, the substance circulation and the closure of BLSS could be improved significantly. In this study, two-step method was conducted to treat the urine and recycle the water and nitrogen. The urea was hydrolyzed firstly, and then the water vapor and ammonia gas were cooled and collected by using reduced pressure distillation in alkaline condition. High temperature acidification and urease processing methods were studied during the urea hydrolysis step. The treatment conditions of both methods were optimized and the degrees of hydrolysis were compared. This investigation may provide a reference for the establishment of the urine recycle in BLSS.

  2. Amphetamine Positive Urine Toxicology Screen Secondary to Atomoxetine

    Directory of Open Access Journals (Sweden)

    Joshua L. Fenderson

    2013-01-01

    Full Text Available The aim of this paper is to report the first case of atomoxetine leading to false-positive urine drug screen. An otherwise healthy 27-year-old female with a history of attention deficit hyperactivity disorder (ADHD treated with atomoxetine had an acute onset tonic-clonic seizure. On arrival to the hospital, a urine toxicological drug screen with immunochemical cloned enzyme donor immunoassay (CEDIA was performed. Results were positive for amphetamines; however, the presence of these substances could not be confirmed with urine gas chromatography-mass spectrometry (GC-MS. She denied any illicit drug use, herbal medications, or supplements, and her other prescription medications have not been previously known to cause a false-positive result for amphetamines. While stimulant treatments for ADHD could certainly result in a positive result on urine screen for amphetamines, there have been no reports of false-positive results for amphetamines secondary to patients using atomoxetine. We implicate atomoxetine, and/or its metabolites, as a compound or compounds which may interfere with urine drug immunoassays leading to false-positive results for amphetamines CEDIA assays.

  3. Ultrasonic-based membrane aided sample preparation of urine proteomes.

    Science.gov (United States)

    Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L

    2018-02-01

    A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Analysis of Urine Flow in Three Different Ureter Models

    Directory of Open Access Journals (Sweden)

    Kyung-Wuk Kim

    2017-01-01

    Full Text Available The ureter provides a way for urine to flow from the kidney to the bladder. Peristalsis in the ureter partially forces the urine flow, along with hydrostatic pressure. Ureteral diseases and a double J stent, which is commonly inserted in a ureteral stenosis or occlusion, disturb normal peristalsis. Ineffective or no peristalsis could make the contour of the ureter a tube, a funnel, or a combination of the two. In this study, we investigated urine flow in the abnormal situation. We made three different, curved tubular, funnel-shaped, and undulated ureter models that were based on human anatomy. A numerical analysis of the urine flow rate and pattern in the ureter was performed for a combination of the three different ureters, with and without a ureteral stenosis and with four different types of double J stents. The three ureters showed a difference in urine flow rate and pattern. Luminal flow rate was affected by ureter shape. The side holes of a double J stent played a different role in detour, which depended on ureter geometry.

  5. Urine Test Strips to Exclude Cerebral Spinal Fluid Blood

    Directory of Open Access Journals (Sweden)

    Marshall, Robin A

    2011-02-01

    Full Text Available Introduction: Determining the presence or absence of red blood cells (RBC or their breakdown products in cerebrospinal fluid (CSF is essential for the evaluation of subarachnoid hemorrhage (SAH in headache patients. Current methodology for finding blood in the CSF is either spectrophotometric detection of pigment, which is time consuming and labor intensive, or visual assesment of samples for color change (xanthochromia, which is inaccurate. Bayer Multistix® urine test strips are designed to test urine for RBC by detecting the presence of hemoglobin. The aim of this pilot study was to evaluate the perfomance of urine reagent test strips for ruling out the presence of RBC in CSF.Methods: We compared color changes on Multistix® urine test strips to the standard of spectrophotometric absorbtion at 415nm and initial RBC counts in 138 visually clear CSF samples.Results: We performed Pearson Chi-Square and likelihood ratios on the results and found a correlation between a negative result on the urine test strip and less than 5 RBC per high power field and a spectrophotometric absorbance of less than 0.02% at 415nm in a CSF sample.Conclusion: These results warrant further investigation in the form of a prospective clinical validation as it may alter the emergency department evaluation for SAH. [West J Emerg Med. 2011;12(1:63-66.

  6. MICROBIOTA URINE BEFORE AND AFTER LITHOTRIPSY FOR RENAL STONES

    Directory of Open Access Journals (Sweden)

    Y. L. Naboka

    2013-01-01

    Full Text Available Extracorporeal shock wave lithotripsy (ESWL in spite of the low invasiveness and high efficiency is accompanied by an infectious- inflammatory complications and renal parenchymal injury . Dynamics of microbial spectrum urine and the impact of postoperative antibiotic therapy currently remains unexplored. The study included 30 patients subjected to ESWL. Bacteriological study was midstream morning urine before ESWL, 1, 3 days after ESWL, and midstream urine in the first urination after ESWL. All patients were divided into 2 groups. Group I consisted of patients (46.7% with antibiotic therapy . Group II patients (53.3 % antibiotic therapy was performed. In most cases (97.8 % were bacteriuria , while in 75% of cases highlighted in the various options bacterial associations representation aerobic- anaerobic mixed infection, among which was dominated by non-clostridial anaerobic bacteria in all samples. Revealed that after ESWL microbial spectrum urine does not change in any case within 3 days , except for Enterobacteriaceae, but the frequency of occurrence and level of bacteriuria vary for different periods after surgery and fees or absence of antibiotic therapy.

  7. Statistical inference on residual life

    CERN Document Server

    Jeong, Jong-Hyeon

    2014-01-01

    This is a monograph on the concept of residual life, which is an alternative summary measure of time-to-event data, or survival data. The mean residual life has been used for many years under the name of life expectancy, so it is a natural concept for summarizing survival or reliability data. It is also more interpretable than the popular hazard function, especially for communications between patients and physicians regarding the efficacy of a new drug in the medical field. This book reviews existing statistical methods to infer the residual life distribution. The review and comparison includes existing inference methods for mean and median, or quantile, residual life analysis through medical data examples. The concept of the residual life is also extended to competing risks analysis. The targeted audience includes biostatisticians, graduate students, and PhD (bio)statisticians. Knowledge in survival analysis at an introductory graduate level is advisable prior to reading this book.

  8. Prevalence of Cannabis Residues in Psychiatric Patients: A Case Study of Two Mental Health Referral Hospitals in Uganda

    Directory of Open Access Journals (Sweden)

    Epaenetus A. Awuzu

    2014-01-01

    Full Text Available Various studies have reported that abuse of cannabis is a risk factor for psychosis. The aims of this study were to determine the prevalence of delta 9-tetrahydrocanabinol (Δ 9 -THC, a major metabolite of cannabis, in psychiatric patients in Uganda, and to assess the diagnostic capacity of two referral mental health hospitals to screen patients for exposure to cannabis in Uganda. Socio-demographic characteristics of the patients were collected through questionnaires and review of medical records. Urine samples were collected from 100 patients and analyzed using Δ 9 -THC immunochromatographic kit (Standard Diagnostics®, South Korea. Seventeen percent of the patients tested positive for Δ 9 -THC residues in their urine. There was strong association ( p < 0.05 between history of previous abuse of cannabis and presence of Δ 9 -THC residues in the urine. Alcohol, cocaine, heroin, pethidine, tobacco, khat and kuber were the other substances abused in various combinations. Both referral hospitals lacked laboratory diagnostic kits for detection of cannabis in psychiatric patients. In conclusion, previous abuse of cannabis is associated with occurrence of the residues in psychiatric patients, yet referral mental health facilities in Uganda do not have the appropriate diagnostic kits for detection of cannabis residues as a basis for evidence-based psychotherapy.

  9. X-ray measurement of residual stress on bolt threads

    International Nuclear Information System (INIS)

    Hagiwara, Masaya; Nakahara, Kanefumi; Yoshimoto, Isamu.

    1989-01-01

    This study deals with X-ray measurement of residual stress at the local area around the thread root of a bolt. Residual stress in the 0.5 mm x 5 mm area was measured using a method of stepped scanning and parabolic approximation. The conditions of measurement had been determined and evaluated through the preliminary measurement of compressive stress acting on the cylindrical surface. Furthermore, the fatigue strength estimated by applying the residual stress data to the previously presented hypothesis was compared with the experimental results. The main conclusions obtained were as follows: (1) The residual stress in a relatively small area on the cylindrical surface with large curvature can be measured by X-ray using a method of stepped scanning and parabolic approximation; (2) The compressive residual stress measured at the thread root was larger for the bolt manufactured by thread rolling after heat treatment than for one manufactured by thread rolling before heat treatment; (3) The distribution of residual stress along the axial direction from the thread root to the portion under crest did not represent remarkable change in its value; (4) The residual stress of a bolt was somewhat decreased by fatigue loading on the condition of low mean stress; (5) The fatigue strength estimated using residual stress data showed the tendency of experimental results well. (author)

  10. On quadratic residue codes and hyperelliptic curves

    Directory of Open Access Journals (Sweden)

    David Joyner

    2008-01-01

    Full Text Available For an odd prime p and each non-empty subset S⊂GF(p, consider the hyperelliptic curve X S defined by y 2 =f S (x, where f S (x = ∏ a∈S (x-a. Using a connection between binary quadratic residue codes and hyperelliptic curves over GF(p, this paper investigates how coding theory bounds give rise to bounds such as the following example: for all sufficiently large primes p there exists a subset S⊂GF(p for which the bound |X S (GF(p| > 1.39p holds. We also use the quasi-quadratic residue codes defined below to construct an example of a formally self-dual optimal code whose zeta function does not satisfy the ``Riemann hypothesis.''

  11. On locating steganographic payload using residuals

    Science.gov (United States)

    Quach, Tu-Thach

    2011-02-01

    Locating steganographic payload usingWeighted Stego-image (WS) residuals has been proven successful provided a large number of stego images are available. In this paper, we revisit this topic with two goals. First, we argue that it is a promising approach to locate payload by showing that in the ideal scenario where the cover images are available, the expected number of stego images needed to perfectly locate all load-carrying pixels is the logarithm of the payload size. Second, we generalize cover estimation to a maximum likelihood decoding problem and demonstrate that a second-order statistical cover model can be used to compute residuals to locate payload embedded by both LSB replacement and LSB matching steganography.

  12. Alkali activation processes for incinerator residues management.

    Science.gov (United States)

    Lancellotti, Isabella; Ponzoni, Chiara; Barbieri, Luisa; Leonelli, Cristina

    2013-08-01

    Incinerator bottom ash (BA) is produced in large amount worldwide and in Italy, where 5.1 millionstons of municipal solid residues have been incinerated in 2010, corresponding to 1.2-1.5 millionstons of produced bottom ash. This residue has been used in the present study for producing dense geopolymers containing high percentage (50-70 wt%) of ash. The amount of potentially reactive aluminosilicate fraction in the ash has been determined by means of test in NaOH. The final properties of geopolymers prepared with or without taking into account this reactive fraction have been compared. The results showed that due to the presence of both amorphous and crystalline fractions with a different degree of reactivity, the incinerator BA geopolymers exhibit significant differences in terms of Si/Al ratio and microstructure when reactive fraction is considered. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. An Additive-Multiplicative Restricted Mean Residual Life Model

    DEFF Research Database (Denmark)

    Mansourvar, Zahra; Martinussen, Torben; Scheike, Thomas H.

    2016-01-01

    mean residual life model to study the association between the restricted mean residual life function and potential regression covariates in the presence of right censoring. This model extends the proportional mean residual life model using an additive model as its covariate dependent baseline....... For the suggested model, some covariate effects are allowed to be time-varying. To estimate the model parameters, martingale estimating equations are developed, and the large sample properties of the resulting estimators are established. In addition, to assess the adequacy of the model, we investigate a goodness...

  14. Use of residue from paper processing as secondary raw material

    International Nuclear Information System (INIS)

    Ernstbrunner, L.

    1994-01-01

    In recent years, the paper industry has been trying to dispose of paper residues by thermal processes in its own, very expensive, combustion plants. Since 1990, the Wopfing Cement Factory, Austria, has been using paper residues in a process for which a patent has now been applied, in a similar way to the method used for the combustion of car tyres in cement rotary kilns. 30.000 t/yr of paper residue is to be processed in Wopfing cement plant from 1995, coming from PWA Ortmann, which is part of a large German paper concern. (author). 4 schemata

  15. Determination of Carbaryl residues in soybean and peanut plants

    International Nuclear Information System (INIS)

    Sumatra, M.; Soejono; Sisworo, W.H.

    1976-01-01

    Carbaryl is one of the insecticides used in large quantities in Indonesia. It is effective against soybean and peanut plant insects. The residues in the plants are determined by Colorimetry at the residues level up to 5 ppm and by thin layer chromatography at level up to 0,1 ppm. Both methods use coupling reaction between hydrolysis product of Carbaryl and diazo reagent to produce colour. (author)

  16. Study of mortars with industrial residual plastic scales

    OpenAIRE

    Magariños, O. E.; Alderete, C. E.; Arias, L. E.; Lucca, M. E.

    1998-01-01

    This work proposes the utilization of industrial residues of PET (Polyethylene Terephtalate) as a partial substitute of arids (sand) in mortar making for construction components. Therefore, the environmental impact of large volumes of plastic of urban residues could be decreased. When PET scales were added to mortars in partial replacement of sand, lower unitary weight, acceptable absorption and resistances according to international specifications were achieved. Mortars with 66% of sand...

  17. Large area imaging of forensic evidence with MA-XRF.

    Science.gov (United States)

    Langstraat, Kirsten; Knijnenberg, Alwin; Edelman, Gerda; van de Merwe, Linda; van Loon, Annelies; Dik, Joris; van Asten, Arian

    2017-11-08

    This study introduces the use of macroscopic X-ray fluorescence (MA-XRF) for the detection, classification and imaging of forensic traces over large object areas such as entire pieces of clothing and wall paneling. MA-XRF was sufficiently sensitive and selective to detect human biological traces like blood, semen, saliva, sweat and urine on fabric on the basis of Fe, Zn, K, Cl and Ca elemental signatures. With MA-XRF a new chemical contrast is introduced for human stain detection and this can provide a valuable alternative when the evidence item is challenging for conventional techniques. MA-XRF was also successfully employed for the chemical imaging and classification of gunshot residues (GSR). The full and non-invasive elemental mapping (Pb, Ba, Sr, K and Cl) of intact pieces of clothing allows for a detailed shooting incident reconstruction linking firearms and ammunition to point of impact and providing information on the shooting angle. In high resolution mode MA-XRF can even be used to provide information on the shooting order of different ammunition types. Finally, by using the surface penetration of X-rays we demonstrate that the lead signature of a bullet impact can be easily detected even if covered by multiple layers of wall paint or human blood.

  18. Estimation of uranium isotope in urine samples using extraction chromatography resin

    International Nuclear Information System (INIS)

    Thakur, Smita S.; Yadav, J.R.; Rao, D.D.

    2012-01-01

    Internal exposure monitoring for alpha emitting radionuclides is carried out by bioassay samples analysis. For occupational radiation workers handling uranium in reprocessing or fuel fabrication facilities, there exists a possibility of internal exposure and urine assay is the preferred method for monitoring such exposure. Estimation of lower concentration of uranium at mBq level by alpha spectrometry requires preconcentration and its separation from large volume of urine sample. For this purpose, urine samples collected from non radiation workers were spiked with 232 U tracer at mBq level to estimate the chemical yield. Uranium in urine sample was pre-concentrated by calcium phosphate coprecipitation and separated by extraction chromatography resin U/TEVA. In this resin extractant was DAAP (Diamylamylphosphonate) supported on inert Amberlite XAD-7 support material. After co-precipitation, precipitate was centrifuged and dissolved in 10 ml of 1M Al(NO 3 ) 3 prepared in 3M HNO 3 . The sample thus prepared was loaded on extraction chromatography resin, pre-conditioned with 10 ml of 3M HNO 3 . Column was washed with 10 ml of 3M HNO 3 . Column was again rinsed with 5 ml of 9M HCl followed by 20 ml of 0.05 M oxalic acid prepared in 5M HCl to remove interference due to Th and Np if present in the sample. Uranium was eluted from U/TEVA column with 15 ml of 0.01M HCl. The eluted uranium fraction was electrodeposited on stainless steel planchet and counted by alpha spectrometry for 360000 sec. Approximate analysis time involved from sample loading to stripping is 2 hours when compared with the time involved of 3.5 hours by conventional ion exchange method. Seven urine samples from non radiation worker were radio chemically analyzed by this technique and the radiochemical yield was found in the range of 69-91 %. Efficacy of this method against conventional anion exchange technique earlier standardized at this laboratory is also being highlighted. Minimum detectable activity

  19. Urine Proteomics in the Era of Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ashley Beasley-Green

    2016-11-01

    Full Text Available With the technological advances of mass spectrometry (MS-based platforms, clinical proteomics is one of the most rapidly growing areas in biomedical research. Urine proteomics has become a popular subdiscipline of clinical proteomics because it is an ideal source for the discovery of noninvasive disease biomarkers. The urine proteome offers a comprehensive view of the local and systemic physiology since the proteome is primarily composed of proteins/peptides from the kidneys and plasma. The emergence of MS-based proteomic platforms as prominent bioanalytical tools in clinical applications has enhanced the identification of protein-based urinary biomarkers. This review highlights the characteristics of urine that make it an attractive biofluid for biomarker discovery and the impact of MS-based technologies on the clinical assessment of urinary protein biomarkers.

  20. From darkening urine to early diagnosis of alkaptonuria

    Directory of Open Access Journals (Sweden)

    Peker Erdal

    2008-01-01

    Full Text Available Alkaptonuria is a rare disorder of metabolism characterized by deficiency of homogentisic acid oxidase. Characteristic features include darkening of urine, ochronosis, and arthropathy. Darkening of urine is the only sign of the disorder in the pediatric age group, and it occurs at very early stage of the disorder, as reported by the parents. A 4-year-old boy presented to our clinic with the complaint of dark urine and bluish black staining of clothes. This darkening pointed to a positive physical history of bluish discoloration of sclerae which occurred off and on. We initiated treatment with ascorbic acid and a protein diet with restriction of phenylalanine and tyrosine (1.6 g/kg/d. This case report is significant because of the early diagnosis made.

  1. Direct detection of glucuronide metabolites of lidocaine in sheep urine.

    Science.gov (United States)

    Doran, Gregory S; Smith, Alistair K; Rothwell, Jim T; Edwards, Scott H

    2018-02-15

    The anaesthetic lidocaine is metabolised quickly to produce a series of metabolites, including several hydroxylated metabolites, which are further metabolised by addition of a glucuronic acid moiety. Analysis of these glucuronide metabolites in urine is performed indirectly by cleaving the glucuronic acid group using β-glucuronidase. However, direct analysis of intact glucuronide conjugates is a more straightforward approach as it negates the need for long hydrolysis incubations, and minimises the oxidation of sensitive hydrolysis products, while also distinguishing between the two forms of hydroxylated metabolites. A method was developed to identify three intact glucuronides of lidocaine in sheep urine using LC-MS/MS, which was further confirmed by the synthesis of glucuronide derivatives of 3OH-MEGX and 4OH-LIDO. Direct analysis of urine allowed the detection of the glucuronide metabolites of hydroxylidocaine (OH-LIDO), hydroxyl-monoethylglycinexylidide (OH-MEGX), and hydroxy-2,6-xylidine (OH-XYL). Analysis of urine before and after β-glucuronidase digestion showed that the efficiency of hydrolysis of these glucuronide metabolites may be underestimated in some studies. Analysis of urine in the current study from three different sheep with similar glucuronide metabolite concentrations resulted in different hydrolysis efficiencies, which may have been a result of different levels of substrate binding by matrix components, preventing enzyme cleavage. The use of direct analysis of intact glucuronides has the benefit of being less influenced by these matrix effects, while also allowing analysis of unstable metabolites like 4OH-XYL, which rapidly oxidises after hydrolysis. Additionally, direct analysis is less expensive and less time consuming, while providing more information about the status of hydroxylated metabolites in urine. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  2. Lateral spread affects nitrogen leaching from urine patches.

    Science.gov (United States)

    Cichota, Rogerio; Vogeler, Iris; Snow, Val; Shepherd, Mark; McAuliffe, Russell; Welten, Brendon

    2018-09-01

    Nitrate leaching from urine deposited by grazing animals is a critical constraint for sustainable dairy farming in New Zealand. While considerable progress has been made to understand the fate of nitrogen (N) under urine patches, little consideration has been given to the spread of urinary N beyond the wetted area. In this study, we modelled the lateral spread of nitrogen from the wetted area of a urine patch to the soil outside the patch using a combination of two process-based models (HYDRUS and APSIM). The simulations provided insights on the extent and temporal pattern for the redistribution of N in the soil following a urine deposition and enabled investigating the effect of lateral spread of urinary N on plant growth and N leaching. The APSIM simulation, using an implementation of a dispersion-diffusion function, was tested against experimental data from a field experiment conducted in spring on a well-drained soil. Depending on the geometry considered for the dispersion-diffusion function (plate or cylindrical) the area-averaged N leaching decreased by 8 and 37% compared with simulations without lateral N spread; this was due to additional N uptake from pasture on the edge area. A sensitivity analysis showed that area-averaged pasture growth was not greatly affected by the value of the dispersion factor used in the model, whereas N leaching was very sensitive. Thus, the need to account for the edge effect may depend on the objective of the simulations. The modelling results also showed that considering lateral spread of urinary N was sufficient to describe the experimental data, but plant root uptake across urine patch zones may still be relevant in other conditions. Although further work is needed for improving accuracy, the simulated and experimental results demonstrate that accounting for the edge effect is important for determining N leaching from urine-affected areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Immunoreactive LH in long-term frozen human urine samples.

    Science.gov (United States)

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Do Mixed-Flora Preoperative Urine Cultures Matter?

    Science.gov (United States)

    Polin, Michael R; Kawasaki, Amie; Amundsen, Cindy L; Weidner, Alison C; Siddiqui, Nazema Y

    2017-06-01

    To determine whether mixed-flora preoperative urine cultures, as compared with no-growth preoperative urine cultures, are associated with a higher prevalence of postoperative urinary tract infections (UTIs). This was a retrospective cohort study. Women who underwent urogynecologic surgery were included if their preoperative clean-catch urine culture result was mixed flora or no growth. Women were excluded if they received postoperative antibiotics for reasons other than treatment of a UTI. Women were divided into two cohorts based on preoperative urine culture results-mixed flora or no growth; the prevalence of postoperative UTI was compared between cohorts. Baseline characteristics were compared using χ 2 or Student t tests. A logistic regression analysis then was performed. We included 282 women who were predominantly postmenopausal, white, and overweight. There were many concomitant procedures; 46% underwent a midurethral sling procedure and 68% underwent pelvic organ prolapse surgery. Preoperative urine cultures resulted as mixed flora in 192 (68%) and no growth in 90 (32%) patients. Overall, 14% were treated for a UTI postoperatively. There was no difference in the proportion of patients treated for a postoperative UTI between the two cohorts (25 mixed flora vs 13 no growth, P = 0.77). These results remained when controlling for potentially confounding variables in a logistic regression model (adjusted odds ratio 0.92, 95% confidence interval 0.43-1.96). In women with mixed-flora compared with no-growth preoperative urine cultures, there were no differences in the prevalence of postoperative UTI. The clinical practice of interpreting mixed-flora cultures as negative is appropriate.

  5. Doping control container for urine stabilization: a pilot study.

    Science.gov (United States)

    Tsivou, Maria; Giannadaki, Evangelia; Hooghe, Fiona; Roels, Kris; Van Gansbeke, Wim; Garribba, Flaminia; Lyris, Emmanouil; Deventer, Koen; Mazzarino, Monica; Donati, Francesco; Georgakopoulos, Dimitrios G; Van Eenoo, Peter; Georgakopoulos, Costas G; de la Torre, Xavier; Botrè, Francesco

    2017-05-01

    Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Does apricot seeds consumption cause changes in human urine?

    Directory of Open Access Journals (Sweden)

    Eva Tušimová

    2017-01-01

    Full Text Available Natural substances, such as amygdalin, used in alternative medicine gained high popularity. Common people as well as patients with different diseases have almost unlimited access to various natural supplements. To protect human health, it is very important to study effect of these substances. Amygdalin is a cyanogenic glucoside derived from seeds of rosaceous plants, for example seeds of bitter almonds (Prunus dulcis, or apricot, cherry, apple, peach, plum, etc. It is a natural product that owns antitumor activity, it has also been used for the treatment of asthma, bronchitis, emphysema, leprosy and diabetes and produces a kind of antitussive and antiasthmatic effects. The present in vivo study was designed to reveal whether amygdalin in apricot seeds has got an effect on human urine composition, pH value and urine associated health status after six weeks of oral administration. The study group finally consisted of 34 healthy adult volunteers (21 females and 13 males. All participants were asked to consume 60 mg.kg-1 body weight of bitter apricot seeds daily (approximately 3.0 mg.kg-1 of amygdalin during 6 weeks. During the experiment, three urine collections were carried out (first collection - at the beginning of the experiment; second collection - after 21 days; third collection - after 42 days. Quantification of urine calcium (Ca, magnesium (Mg, phosphorus (P, sodium (Na, potassium (K, chlorides (Cl-, urea and pH value after apricot seeds supplementation was performed. Statistical analysis of variance showed, that consumption of bitter apricot seeds during 42 days had a significant (p <0.01 effect on amount of calcium excreted in urine, though this decrease shifted its level from elevated mean value in control collection into normal physiological range. Significant changes were observed in urea (p <0.05 and phosphorus (p <0.01 levels in urine after apricot seed ingestion, but gender was also considered to be a source of their variation.

  7. Application of kidney inhibition swab tests to evaluate penicillin-G residues in sow tissues and body fluids following intramuscular injection

    Science.gov (United States)

    Kidney inhibition swab (KIS) tests, recently adapted by the US FSIS for antibiotics on-site screening, were employed to evaluate the depletion of penicillin-G residues from kidney, liver, muscle, serum, and urine of sows after intramuscular (IM) penicillin-G procaine administration. Sows (n=130; 22...

  8. Residual stress by repair welds

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Toyoda, Masao

    2003-01-01

    Residual stress by repair welds is computed using the thermal elastic-plastic analysis with phase-transformation effect. Coupling phenomena of temperature, microstructure, and stress-strain fields are simulated in the finite-element analysis. Weld bond of a plate butt-welded joint is gouged and then deposited by weld metal in repair process. Heat source is synchronously moved with the deposition of the finite-element as the weld deposition. Microstructure is considered by using CCT diagram and the transformation behavior in the repair weld is also simulated. The effects of initial stress, heat input, and weld length on residual stress distribution are studied from the organic results of numerical analysis. Initial residual stress before repair weld has no influence on the residual stress after repair treatment near weld metal, because the initial stress near weld metal releases due to high temperature of repair weld and then stress by repair weld regenerates. Heat input has an effect for residual stress distribution, for not its magnitude but distribution zone. Weld length should be considered reducing the magnitude of residual stress in the edge of weld bead; short bead induces high tensile residual stress. (author)

  9. Smartphone based point-of-care detector of urine albumin

    Science.gov (United States)

    Cmiel, Vratislav; Svoboda, Ondrej; Koscova, Pavlina; Provaznik, Ivo

    2016-03-01

    Albumin plays an important role in human body. Its changed level in urine may indicate serious kidney disorders. We present a new point-of-care solution for sensitive detection of urine albumin - the miniature optical adapter for iPhone with in-built optical filters and a sample slot. The adapter exploits smart-phone flash to generate excitation light and camera to measure the level of emitted light. Albumin Blue 580 is used as albumin reagent. The proposed light-weight adapter can be produced at low cost using a 3D printer. Thus, the miniaturized detector is easy to use out of lab.

  10. X-ray fluorescent analysis of iodin traces in urine

    International Nuclear Information System (INIS)

    Mikhajlov, I.F.; Baturin, A.A.; Mikhajlov, A.I.; Borisova, S.S.; Reshetnyak, M.V.; Shlyakhova, N.V.; Budrejko, E.A.; Galata, D.I.

    2015-01-01

    Using XFA method, determination of iodine concentration in urine for 35 children of 10-15 with endocrine pathology (delay of sexual development, diffuse goiter, obesity) and 10 practically healthy children being observed under conditions of the consultative polyclinic and the department of endocrinology of SI ''ISHCJ NAMSU''. The proposed optimized XFA method allows by 1-2 orders increasing detection sensitivity for micro-elements measurements in biology objects and attaining the iodine trace contents in urine in the range from 50 to 200 gg/dm 3

  11. Development of rapid urine analysis method for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, J.; Noguchi, H. [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-05-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  12. History of PUQFUA: plutonium body burden (Q) from urine assays

    International Nuclear Information System (INIS)

    Lawrence, J.N.P.

    1978-10-01

    PUQFUA is a FORTRAN computer program that calculates plutonium body burdens (Q) from urine assay data. This report describes the historical development of the program at the Los Alamos Scientific Laboratory (LASL) since 1959. After a review of the basic techniques used in the original PUQFUA, its deficiencies are listed. The procedures used to improve the program and correct the deficiencies are described. Appendixes provide a detailed discussion of the evaluation made of the analytical errors in the plutonium urine assay program at LASL from 1944 to 1978

  13. The optimization of the analysis of chlorine-36 in urine

    International Nuclear Information System (INIS)

    Joseph, S.; Kramer, G.H.

    1982-02-01

    A method has been developed and optimized for the analysis of chlorine-36 in urine. Problems such as sample size, photodecomposition of silver chloride and anion interferences have been solved and are discussed in detail. The analysis is performed by first removing interfering phosphates and sulphates from an untreated urine sample and isolating the chlorine-36 as silver chloride. The precipitate is counted in a planchet counter. Recoveries are estimated to be 90 +- 5% with a detection limit of 3 pCi (0.1 Bq) for a routine sample (counting time 10 minutes, counting efficiency 10%, sample size 100 mL)

  14. Study of nominal daily output of urine from workers

    International Nuclear Information System (INIS)

    Lima, Marina F.; Carneiro, Janete C.G. Gaburo; Todo, Alberto S.

    2007-01-01

    A retrospective study of the 24-hour urine volumes from workers selected for the internal individual monitoring compares the average volume collected by sample and the average volume per individual with the nominal daily output of urine from 'Reference Man'. This work considers 134 registers of urine samples from 18 male workers, with semester routine sampling, between the years of 2000 and 2005. For this group, the average volume per collection was (971±371)mL and (962±376)mL per individual. In a cohort group of 9 male workers, which supplied at least 10 samples in this period, it was observed that the average volume per collection decreased to (955±308)mL and the average volume per individual increased to (1027±400)mL. For the female group, composed by 11 individuals, the 29 urine samples supplied between 1999 and 2005 were considered. The average volume per sampling and for worker was, respectively, (1122±337)mL and (1105±337)mL. Another cohort group of only 4 female workers with at least one annual collection during five years, of the seven years considered, the values decreased to (1112±336)mL per collection and the average volume per individual was maintained. The major variability of the volume among all the individuals was 927%, and for the same individual was 562%. This difference can be indicative of the individual differences of retention and excretion, alimentary diet interferences and for lack of awareness by the individual to collect urine during a period of 24-hour. The radionuclides clearance does not occur in constant rates and for the purpose of assessing intakes, in our routine analysis, the total volume of urine from worker is corrected for 1,4 L. Based in the results obtained over the years, and to minimize the errors of the nominal daily excretion rate in urine, actions about the aware of the individual in carrying out an accurately sampling and/or the implementation of the measurements of creatinine levels in urine are suggested

  15. Estimation of 239Pu in urine, influence of Sulkowich reagent

    International Nuclear Information System (INIS)

    Kalaiselvan, S.; Prasad, M.V.R.; Jeevanram, R.K.

    1988-01-01

    Plutonium is known to be co-precipitated with Sulkowich reagent as calcium ammonium oxalate. In adopting this technique for bio-assay of plutonium, its accuracy depends on the self-absorption of the resulting precipitate in each urine sample. Pu recovery experiments were carried out with varying concentration of Ca and Mg, using different volumes of Sulkowich reagent. When the sample volume is 500 ml, Pu in urine can be estimated with an accuracy and precision of 74.38%+-7.4%, with a detection limit of 0.06 Bq (1.6 pCi) per dm 3 . (author) 3 refs.; 2 figs.; 2 tabs

  16. Infecções do trato urinário

    OpenAIRE

    Barros, Susana; Cambão, Marta; Vieira, Sandra; Estevinho, Leticia M.

    2005-01-01

    O sistema urinário é uma das quatro vias de excreção existentes no corpo humano. A sua exposição a factores exteriores e/ou interiores torna-o sensível a diversas infecções, pelo que, actualmente, em termos de quadro clínico. as patologias relacionadas com as infecções do tracto urinário (ITU), nomeadamente, a uretrite, cistite, síndroma uretral agudo e pielonefrite, são bastantes comuns.

  17. Serum and Urine Copper – Contamination and Stability

    OpenAIRE

    Dimitrova Ivanova I.; Atanasova B.; Dragneva S.; Vladimirova L.; Krastev Z.; Kostadinova A.; Ivanova A.; Tzatchev K.

    2015-01-01

    Pre-analytical factors of variation need to be carefully considered and investigated in efforts to harmonize all aspects of the total testing process. This study aimed to evaluate contamination and stability in copper (Cu) analysis of serum and urine by flame atomic absorption spectroscopy (FAAS) and to compare the stability of urine Cu in controls and in D-penicillamine (D-PA) administration. Cu was measured by AAnalyst 400, Perkin Elmer, USA. Blood was collected in BD Vacutainer®SSTTM II Ad...

  18. Development of rapid urine analysis method for uranium

    International Nuclear Information System (INIS)

    Kuwabara, J.; Noguchi, H.

    2000-01-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  19. The optimization of the analysis of nickel-63 in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.

    1981-05-01

    A method has been developed that separates nickel-63 from urine. The subsequent estimation of activity is by liquid scintillation counting. The urine is wet ashed by a new procedure which is much faster than conventional ashing methods. Interfering phosphates are removed prior to a precipitation of Ni as the dimethylglyoxime complex. The effects of the carrier weight, the pH of the phosphate removal step and the pH of the dimethylglyoxime precipiation have been investigated and optimized to give a mean recovery of 97 +- 8% for nickel-63. The detection limit is estimated to be 1.5 pCi (55 mBq) per sample. (author)

  20. Impact of cleaning before obtaining midstream urine samples from children

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Knudsen, Jenny Dahl; Ladelund, Steen

    2014-01-01

    INTRODUCTION: Microbiological documentation of one uropathogenic bacterium in significant numbers in urine from patients with typical symptoms is the gold standard for diagnosing urinary tract infection (UTI). Cleaning before collecting midstream urine (MSU) is reported not to reduce the risk...... of contaminating the sample and was therefore omitted at Hvidovre Hospital as from the autumn of 2006. We evaluate if no cleaning increased the risk of contamination in the Department of Paediatrics. MATERIAL AND METHODS: A total of 1,858 patients aged 0-15 years who were suspected of UTI delivered two MSUs within...

  1. Investigation of the daily variation in iodine and creatinine excretion in human urine

    International Nuclear Information System (INIS)

    Aabech, H.S.

    1975-08-01

    Continuing earlier investigations of the level of iodine intake in Norway, the excretion of iodine in 24-hour samples of urine over 7 days has been measured for 23 persons. Three of them collected 24-hour samples of urine during continuous periods of 21, 22 and 54 days. The main aim of the investigation was to study the diurnal variation of iodine excretion , and to correlate it with diet components when connection was suspected. To this end the persons had to keep record of the diet, especially with respect to fish and fish products. The variation from day to day of the iodine excretion was much greater than expected, and the highest values were always preceded by meals of sea-fish. Mean 24-hour iodine excretion from 13 males was 266 μg/24h (range 54-2272), from 8 females 154 μg/24h (range 58-627), and from 2 children 74 μg/24h (range 33-129). Large fluctuations were present, as indicated by standard deviations that varied from 12 to 119% of the mean. None of the persons had a mean 24-hour excretion lower than the advised minimum of 1 μg iodine/kg b w. The excretion of creatinine has also been measured, and the excretion from day to day showed large fluctuations for some of the persons. In 13 males the mean 24-hour excretion of creatinine was 1.88 gram (range 0.81-2.93), and in 8 females 1.17 gram (range 0.47-1.74). In one person, who collected urine during a period of 54 days, the mean excretion of creatinine was 1.80 gram (range 1.19-2.75). (auth.)

  2. Urine proteome analysis in Dent's disease shows high selective changes potentially involved in chronic renal damage.

    Science.gov (United States)

    Santucci, Laura; Candiano, Giovanni; Anglani, Franca; Bruschi, Maurizio; Tosetto, Enrica; Cremasco, Daniela; Murer, Luisa; D'Ambrosio, Chiara; Scaloni, Andrea; Petretto, Andrea; Caridi, Gianluca; Rossi, Roberta; Bonanni, Alice; Ghiggeri, Gian Marco

    2016-01-01

    Definition of the urinary protein composition would represent a potential tool for diagnosis in many clinical conditions. The use of new proteomic technologies allows detection of genetic and post-trasductional variants that increase sensitivity of the approach but complicates comparison within a heterogeneous patient population. Overall, this limits research of urinary biomarkers. Studying monogenic diseases are useful models to address this issue since genetic variability is reduced among first- and second-degree relatives of the same family. We applied this concept to Dent's disease, a monogenic condition characterised by low-molecular-weight proteinuria that is inherited following an X-linked trait. Results are presented here on a combined proteomic approach (LC-mass spectrometry, Western blot and zymograms for proteases and inhibitors) to characterise urine proteins in a large family (18 members, 6 hemizygous patients, 6 carrier females, and 6 normals) with Dent's diseases due to the 1070G>T mutation of the CLCN5. Gene ontology analysis on more than 1000 proteins showed that several clusters of proteins characterised urine of affected patients compared to carrier females and normal subjects: proteins involved in extracellular matrix remodelling were the major group. Specific analysis on metalloproteases and their inhibitors underscored unexpected mechanisms potentially involved in renal fibrosis. Studying with new-generation techniques for proteomic analysis of the members of a large family with Dent's disease sharing the same molecular defect allowed highly repetitive results that justify conclusions. Identification in urine of proteins actively involved in interstitial matrix remodelling poses the question of active anti-fibrotic drugs in Dent's patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. RESIDUAL RISK ASSESSMENT: ETHYLENE OXIDE ...

    Science.gov (United States)

    This document describes the residual risk assessment for the Ethylene Oxide Commercial Sterilization source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Ethylene Oxide Commercial Sterilization source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  4. Bound residues in corn plants treated with 14C-atrazine and bioavailability to rats

    International Nuclear Information System (INIS)

    Khan, S.U.

    1986-01-01

    Corn plants, about 3.5 months old and treated with 14 C-atrazine, were used in an experiment in which the aerial portion of the plants was exhaustively extracted with solvents. The extracted dried material containing bound 14 C-residues was fed to rats. The extracted aerial portion of control corn plants fortified with 14 C-atrazine was also fed to rats. After four days, 88% and 32% of the radioactivity was excreted in the faeces, and 10% and 60% radioactivity was voided in the urine from rats fed plant material containing bound and fortified 14 C-residues, respectively. The data suggest that the bioavailability to rats of bound 14 C-residues in corn material is low. (author)

  5. Diuretics, Limited Ultrafiltration, and Residual Renal Function in Incident Hemodialysis Patients: A Case Series.

    Science.gov (United States)

    Sjolund, Jessica; Garcia Anton, Desiree; Bayes, Liz Y; Hoekstra, Tiny; Dekker, Friedo W; Munoz Mendoza, Jair

    2016-09-01

    The effect of diuretics on residual renal function expressed as residual GFR (rGFR) and urine volume (rUV) using 24-hour urine collections has not been well examined in hemodialysis (HD) patients. We present a small (seven patient) but provocative case series describing a strikingly low rate of decline in rUV and rGFR (average of creatinine and urea clearances, 24-hour urine collections) in patients treated with increasing doses of furosemide (up to 360 mg/day) during the first 2 years after initiation of HD. Between 6 and 12 months, the mean rUV fell by 1 ml/month, whereas rGFR declined by 0.03 ml/min/1.73 m(2) /month. The mean rate of decline from 12 to 24 months for rUV (33 ml/month) and rGFR (0.02 ml/min/1.73 m(2) /month) were also low. While data are clearly limited and the observation retrospective, they are consistent with the better documented benefit of diuretics observed in end-stage renal disease patients treated with peritoneal dialysis. © 2016 Wiley Periodicals, Inc.

  6. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    Science.gov (United States)

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  7. Residual stresses in zircaloy welds

    International Nuclear Information System (INIS)

    Santisteban, J. R.; Fernandez, L; Vizcaino, P.; Banchik, A.D.; Samper, R; Martinez, R. L; Almer, J; Motta, A.T.; Colas, K.B; Kerr, M.; Daymond, M.R

    2009-01-01

    Welds in Zirconium-based alloys are susceptible to hydrogen embrittlement, as H enters the material due to dissociation of water. The yield strain for hydride cracking has a complex dependence on H concentration, stress state and texture. The large thermal gradients produced by the applied heat; drastically changes the texture of the material in the heat affected zone, enhancing the susceptibility to delayed hydride cracking. Normally hydrides tend to form as platelets that are parallel to the normal direction, but when welding plates, hydride platelets may form on cooling with their planes parallel to the weld and through the thickness of the plates. If, in addition to this there are significant tensile stresses, the susceptibility of the heat affected zone to delayed hydride cracking will be increased. Here we have measured the macroscopic and microscopic residual stressed that appear after PLASMA welding of two 6mm thick Zircaloy-4 plates. The measurements were based on neutron and synchrotron diffraction experiments performed at the Isis Facility, UK, and at Advanced Photon Source, USA, respectively. The experiments allowed assessing the effect of a post-weld heat treatment consisting of a steady increase in temperature from room temperature to 450oC over a period of 4.5 hours; followed by cooling with an equivalent cooling rate. Peak tensile stresses of (175± 10) MPa along the longitudinal direction were found in the as-welded specimen, which were moderately reduced to (150±10) MPa after the heat-treatment. The parent material showed intergranular stresses of (56±4) MPa, which disappeared on entering the heat-affected zone. In-situ experiments during themal cyclong of the material showed that these intergranular stresses result from the anisotropy of the thermal expansion coefficient of the hexagonal crystal lattice. [es

  8. Suitability of bovine bile compared to urine for detection of free, sulfate and glucuronate boldenone, androstadienedione, cortisol, cortisone, prednisolone, prednisone and dexamethasone by LC-MS/MS.

    Science.gov (United States)

    Chiesa, Luca; Nobile, Maria; Panseri, Sara; Vigo, Daniele; Pavlovic, Radmila; Arioli, Francesco

    2015-12-01

    The administration of boldenone and androstadienedione to cattle is forbidden in the European Union, while prednisolone is permitted for therapeutic purposes. They are pseudoendogenous substances (endogenously produced under certain circumstances). The commonly used matrices in control analyses are urine or liver. With the aim of improving the residue controls, we previously validated a method for steroid analysis in bile. We now compare urine (a 'classic' matrix) to bile, both collected at the slaughterhouse, to understand whether the detection of steroids in the latter is easier. With the aim of having clearer results, we tested the presence of the synthetic corticosteroid dexamethasone. The results show that bile does not substantially improve the detection of boldenone, or its conjugates, prednisolone and prednisone. Dexamethasone, instead, was found in 10 out of 53 bovine bile samples, but only in one urine sample from the same animals. Bile could constitute a novel matrix for the analysis of residues in food-producing animals, and possibly not only of synthetic corticosteroids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Comparison between the urine dipstick and the pH-meter to assess urine pH in sheep and dogs.

    Science.gov (United States)

    Athanasiou, Labrini V; Katsoulos, Panagiotis D; Katsogiannou, Eleni G; Polizopoulou, Zoe S; Diamantaki, Myrto; Kamatsos, Constantinos; Christodoulopoulos, Georgios

    2018-02-06

    Urine pH is an integral part of a complete urinalysis, and is commonly measured in veterinary practice using semiquantitative reagent strips. The aim of this study was to compare the urine pH of dogs and sheep, using visual interpretation of dipstick reactions, and using a pH-meter as the reference method. Agreement between the 2 methods was also assessed. An additional objective was to compare the urine pH before and after centrifugation. A total of 50 voided urine samples from sheep and 52 from dogs were collected into sterile containers. For pH measurements, 2 methods were used, a pH-meter and urine dipstick reagent pads. Measurements were performed using urine samples before (whole urine) and after centrifugation (urine supernatant). For comparison of the 2 methods, Passing and Bablok regression analysis and Bland-Altman plots were used. The equation created to assess agreement between the 2 methods in dogs showed a constant bias at -0.14 and a positive proportional bias at 0.98. From a clinical standpoint, total bias was below and above the maximum acceptable bias in sheep and dogs, respectively. Clinically acceptable bias was also found using centrifuged urine samples in sheep, but the urine pH values before and after centrifugation were nearly identical in dogs. Urine dipstick reagent pads and pH-meters can be used interchangeably to determine urine pH in sheep without needing centrifugation. In contrast, pH-meters provide more accurate pH measurements than urine dipstick pads in canine urine, which is not improved by centrifugation. © 2018 American Society for Veterinary Clinical Pathology.

  10. Nitrogen availability of biogas residues

    Energy Technology Data Exchange (ETDEWEB)

    El-Sayed Fouda, Sara

    2011-09-07

    The objectives of this study were to characterize biogas residues either unseparated or separated into a liquid and a solid phase from the fermentation of different substrates with respect to their N and C content. In addition, short and long term effects of the application of these biogas residues on the N availability and N utilization by ryegrass was investigated. It is concluded that unseparated or liquid separated biogas residues provide N at least corresponding to their ammonium content and that after the first fertilizer application the C{sub org}:N{sub org} ratio of the biogas residues was a crucial factor for the N availability. After long term application, the organic N accumulated in the soil leads to an increased release of N.

  11. Vesícula residual

    Directory of Open Access Journals (Sweden)

    Júlio C. U. Coelho

    Full Text Available Our objective is to report three patients with recurrent severe upper abdominal pain secondary to residual gallbladder. All patients had been subjected to cholecystectomy from 1 to 20 years before. The diagnosis was established after several episodes of severe upper abdominal pain by imaging exams: ultrasonography, tomography, or endoscopic retrograde cholangiography. Removal of the residual gallbladder led to complete resolution of symptoms. Partial removal of the gallbladder is a very rare cause of postcholecystectomy symptoms.

  12. Residual number processing in dyscalculia ?

    OpenAIRE

    Cappelletti, Marinella; Price, Cathy J.

    2013-01-01

    Developmental dyscalculia – a congenital learning disability in understanding numerical concepts – is typically associated with parietal lobe abnormality. However, people with dyscalculia often retain some residual numerical abilities, reported in studies that otherwise focused on abnormalities in the dyscalculic brain. Here we took a different perspective by focusing on brain regions that support residual number processing in dyscalculia. All participants accurately performed semantic and ca...

  13. Americium recovery from reduction residues

    Science.gov (United States)

    Conner, W.V.; Proctor, S.G.

    1973-12-25

    A process for separation and recovery of americium values from container or bomb'' reduction residues comprising dissolving the residues in a suitable acid, adjusting the hydrogen ion concentration to a desired level by adding a base, precipitating the americium as americium oxalate by adding oxalic acid, digesting the solution, separating the precipitate, and thereafter calcining the americium oxalate precipitate to form americium oxide. (Official Gazette)

  14. Residual extrapolation operators for efficient wavefield construction

    KAUST Repository

    Alkhalifah, Tariq Ali

    2013-02-27

    Solving the wave equation using finite-difference approximations allows for fast extrapolation of the wavefield for modelling, imaging and inversion in complex media. It, however, suffers from dispersion and stability-related limitations that might hamper its efficient or proper application to high frequencies. Spectral-based time extrapolation methods tend to mitigate these problems, but at an additional cost to the extrapolation. I investigate the prospective of using a residual formulation of the spectral approach, along with utilizing Shanks transform-based expansions, that adheres to the residual requirements, to improve accuracy and reduce the cost. Utilizing the fact that spectral methods excel (time steps are allowed to be large) in homogeneous and smooth media, the residual implementation based on velocity perturbation optimizes the use of this feature. Most of the other implementations based on the spectral approach are focussed on reducing cost by reducing the number of inverse Fourier transforms required in every step of the spectral-based implementation. The approach here fixes that by improving the accuracy of each, potentially longer, time step.

  15. The optical nature of methylsuccinic acid in human urine

    Science.gov (United States)

    Zeitman, B.; Lawless, J. G.

    1975-01-01

    Methylsuccinic acid was isolated from human urine, derivatized as the di-S-(+)-2-butyl ester, and analyzed using a gas chromatographic system capable of separating the enantiomers of the derivative. The R-(+)-isomer was found to be present. Methylsuccinic acid is potentially important as a criterion for abiogenicity, having been obtained as a racemic mixture from sources known to be abiotic.

  16. Urine management after treatment with ''153 Sm-EDTMP (QUADRAMET)

    International Nuclear Information System (INIS)

    Delgado, A.; Diaz, J. P.; Carrasco, J. L.; Jimenez-Hoyuela, J. M.; Rebollo, A. C.; Martinez del Valle, M. D.; Ortega, S. J.

    2004-01-01

    The main purpose was to establish and to evaluate a new protocol of individualized treatment of patient urine after ''153 Sm-EDTMP injection, with a more efficient management of the wastes. Excreted urine was collected in an appropriate container form which, previous to sealing it, an aliquot of 10 ml was obtained. Experimental half-life (t1/2) of the isotope was then determined by measuring the activity at different times, besides the minimum time necessary for disposing of the radioactive wastes as regular trash. The measured half-life adjusted well to the theoretical value of the isotope. The time of considered storage oscillated between 19 and 26 days, based on the activity excreted by each patient. The main idea is the consideration of the set container-urine as solid waste: the evaluation of the minimum storage time necessary to its elimination is made in terms of legal limitation of specific activity by mass unit. The immediate advantages ares: the elimination of disagreeable scents by the storage of urine, it is not necessary a liquid waste disposal to eliminate it, and a more accurate knowledge of the specific activity at the moment of the elimination (dilution factor is not used). (Author) 10 refs

  17. Radioimmunoassay of antidiuretic hormone in human urine. Applications

    International Nuclear Information System (INIS)

    Zebidi, Abdelkrim.

    1977-10-01

    This work is devoted mainly to the development of a radioimmunological system of antidiuretic hormone (ADH) determination in the urine and its physiological and pathological applications. The radioimmunological method thus replaces the biological measurement of antidiuretic hormone in the urine. This new technique was not possible until specific arginine vasopressin antibodies were obtained and a labelled hormone was prepared according to the criteria set for a radioimmunoassay. The labelled hormone is lysine vasopressin (greater stability). Although 125 I-LVP has lost most of its biological activity the molecule keeps all its immunological properties, behaving in the same way as non-iodinated synthetic LVP towards anti-LVP antibodies. Once specific antivasopressin antibodies and immunologically competent labelled hormone were available, conditions were defined for the radioimmunological ADH test in the urine. This technique, relatively easy to use, allows twenty samples to be measured simultaneously. With this sensitive, specific and reproducible method, it is thus possible to estimate the urinary ADH excretion rates from a 20 ml volume of urine after previous extraction on amberlite CG 50. This extraction method is aimed at both concentrating the hormone and eliminating non-specific interferences. The hormone extraction yield is about 92%+-8 [fr

  18. Purple Urine Bag Syndrome: A Case Report | Gandhi | Internet ...

    African Journals Online (AJOL)

    Purple urine bag syndrome (PUBS) is an uncommon phenomenon reported mostly in chronically constipated, institutionalized females on an indwelling catheter. It can often cause tremendous distress among health care providers. Though the condition is generally described as benign, it should draw immediate attention to ...

  19. effect of chronic consumption of cow's urine concoction on gastric ...

    African Journals Online (AJOL)

    Dr Olaleye

    The effect of chronic consumption of cow's urine concoction (CUC) and the role of tobacco leaves was studied on the gastric ... CUC-T fed group showed 80% reduction but the pyloric glands in group fed with CUC-NT were not reduced. ... The concoction was given orally through a plastic tube as reported by other authors.

  20. Measurement of purine derivatives and creatinine in urine by HPLC

    International Nuclear Information System (INIS)

    Piani, B.; Fabro, C.; Susmel, P.

    2004-01-01

    Two HPLC methods to measure the purine derivatives (PD, including allantoin, uric acid, hypoxanthine and xanthine) and creatinine content in urine are described. PD separation and quantification were achieved using two Spherisorb ODS 2 reversed phase columns connected in series (4.6 x 250 mm) and a Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), which was used at a flow rate of 0.8 ml/min and the detection wavelength was at 190 nm. The average recoveries of standard compounds added to urine samples were satisfactory (92-106%) and the low detection limits (0.7-3.4 μM) permitted the precise determination of these compounds in urine. Separation and quantification of creatinine was achieved using one Spherisorb ODS 2 reversed phase column (4.6 x 250 mm) and one Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), used at a flow rate of 1.00 ml/min and the detection was at 190 nm. The mean recovery (3 measurements) of standard solution added to urine samples was 101%; detection limit was 7.9 μM. (author)

  1. Antimicrobial activity of photo-activated cow urine against certain ...

    African Journals Online (AJOL)

    ONOS

    2010-01-25

    Jan 25, 2010 ... cow urine has shown 32 to 36 mm inhibition zone diameter homogeneously against all bacterial strains. It proves very high antimicrobial ... For control of microbial infections and diseases, various synthetic drugs and chemical ..... Protein and amino acid metabolism in the intestinal tract of growing bulls.

  2. Terbutaline accumulates in blood and urine following daily therapeutic inhalation

    DEFF Research Database (Denmark)

    Krogh, Nanna; Rzeppa, Sebastian; Dyreborg, Anders

    2017-01-01

    ×d) of inhaled terbutaline. After inhalation of terbutaline at each trial, subjects performed 90 min of bike ergometer exercise at 65% of maximal oxygen consumption after which they stayed inactive. Blood and urine samples were collected before and after inhalation of terbutaline. Samples were analyzed by high...

  3. A girl with headache, confusion and green urine.

    Science.gov (United States)

    Hufschmidt, Andreas; Krisch, Alexandra; Peschen, I

    2009-07-01

    The case of a 17-year-old girl with a history of headache, blurred vision, confusion, ataxia and syncope is presented. On admission, she had already recovered except for a slurring of speech. Her urine was found to be green. Screening for illegal drugs was negative, but gas chromatography with subsequent mass spectroscopy (GC-MS) revealed an extremely high concentration of flupirtine.

  4. Natural levels of 210Po in human urine

    International Nuclear Information System (INIS)

    Diaz-Frances, I.; Garcia-Tenorio, R.; Mantero, J.; Diaz, J.; Manjon, G.

    2013-01-01

    The daily activity of 2 10Po concentrations in the urine of a volunteer for a month analyzed studies show a high variability with a difference of up to an order of magnitude between the maximum and minimum values obtained, and a clear dependence on the type of diet followed in the various phases of the experiment. (Author)

  5. Patient Specific Dosimetry based in excreted urine measurements

    Energy Technology Data Exchange (ETDEWEB)

    Barquero, R.; Nunez, C.; Ruiz, A.; Valverde, J.; Basurto, F.

    2006-07-01

    One of the limiting factors in utilising therapeutic radiopharmaceuticals in the I-131 thyroid therapy is the potential hazard to the bone marrow, kidneys, and other internal organs. In this work, by means of daily dose rate measurements at a point in contact of the can with the urine excreted by the patient undergoing radio-iodine therapy, activities and associated absorbed doses in total body are calculated. The urine can is characterised by a geometric and materials model for MC simulation with MCNP. Knowing the conversion factor from activity in urine to dose rate in the measurement point of the can for each filling volume, the urine and patient activity can be obtained at each measurement time. From the fitting of these activities, the time evolution, the effective half life in the patient and the cumulative whole body activity are calculated. The emission characteristics of I-131 are using after to estimate the maximum whole body absorbed dose. The results for 2 hyperthyroidism and 4 carcinoma treatments are presented. The maximum total body absorbed dose are 673 and 149 Gy for the carcinoma and hyperthyroidism. The corresponding range of T1/2 eff is o.2 to 2.5 days (carcinoma) and 5.4 to 6.6 days (hyperthyroidism). (Author)

  6. Urine Test: Microalbumin-to-Creatinine Ratio (For Parents)

    Science.gov (United States)

    ... could interfere with test results. Be sure to review all your child's medications with your doctor. The Procedure Your child will be asked to urinate (pee) into a clean sample cup in the doctor's office or at home. Collecting the specimen should only take a few minutes. If your child isn' ...

  7. Fetal urine biochemistry in antenatal Bartter syndrome: a case report.

    Science.gov (United States)

    Rachid, Myriam L; Dreux, Sophie; Czerkiewicz, Isabelle; Deschênes, Georges; Vargas-Poussou, Rosa; Mahieu-Caputo, Dominique; Oury, Jean-François; Muller, Françoise

    2016-09-01

    Bartter syndrome is a severe inherited tubulopathy responsible for renal salt wasting, and hence electrolyte disorders and dehydration. Prenatally, it is characterized by severe polyhydramnios caused by fetal polyuria. We studied for the first time fetal urine in a Bartter syndrome case and demonstrated that the tubulopathy is already present at 24 weeks of gestation.

  8. Antibiotics susceptibility patterns of urine bacterial isolates in Zaria ...

    African Journals Online (AJOL)

    Conclusion: Ps aeruginosa, Staph aureus and E. coli are highly prevalent in urine of the residents of Zaria investigated. The high multiple antibiotics resistance identified makes it necessary for antibiotic susceptibility testing to be conducted prior to antibiotics prescription in in Zaria. Key words: Antibiotics resistance; bacteria; ...

  9. Analysis of Urine for Pure Beta Emitters: Methods and Application

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2011-01-01

    Bioassay for individual radionuclides is an essential and first step in estimation of radiation risk to nuclear facilities workers and people who are exposed to the contaminated environment in the event of a nuclear accident or radiological attack. Urine is a frequently used biological sample for...

  10. Residue number systems theory and applications

    CERN Document Server

    Mohan, P V Ananda

    2016-01-01

    This new and expanded monograph improves upon Mohan's earlier book, Residue Number Systems (Springer, 2002) with a state of the art treatment of the subject. Replete with detailed illustrations and helpful examples, this book covers a host of cutting edge topics such as the core function, the quotient function, new Chinese Remainder theorems, and large integer operations. It also features many significant applications to practical communication systems and cryptography such as FIR filters and elliptic curve cryptography. Starting with a comprehensive introduction to the basics and leading up to current research trends that are not yet widely distributed in other publications, this book will be of interest to both researchers and students alike.

  11. Lactic acid fermentation of human urine to improve its fertilizing value and reduce odour emissions.

    Science.gov (United States)

    Andreev, N; Ronteltap, M; Boincean, B; Wernli, M; Zubcov, E; Bagrin, N; Borodin, N; Lens, P N L

    2017-08-01

    During storage of urine, urea is biologically decomposed to ammonia, which can be lost through volatilization and in turn causes significant unpleasant smell. In response, lactic acid fermentation of urine is a cost-effective technique to decrease nitrogen volatilization and reduce odour emissions. Fresh urine (pH = 5.2-5.3 and NH 4 + -N = 1.2-1.3 g L -1 ) was lacto-fermented for 36 days in closed glass jars with a lactic acid bacterial inoculum from sauerkraut juice and compared to untreated, stored urine. In the lacto-fermented urine, the pH was reduced to 3.8-4.7 and the ammonium content by 22-30%, while the pH of the untreated urine rose to 6.1 and its ammonium content increased by 32% due to urea hydrolysis. The concentration of lactic acid bacteria in lacto-fermented urine was 7.3 CFU ml -1 , suggesting that urine is a suitable growth medium for lactic acid bacteria. The odour of the stored urine was subjectively perceived by four people to be twice as strong as that of lacto-fermented samples. Lacto-fermented urine induced increased radish germination compared to stored urine (74-86% versus 2-31%). Adding a lactic acid bacterial inoculum to one week old urine in the storage tanks in a urine-diverting dry toilet reduced the pH from 8.9 to 7.7 after one month, while the ammonium content increased by 35%, probably due to the high initial pH of the urine. Given that the hydrolyzed stale urine has a high buffering capacity, the lactic acid bacterial inoculum should be added to the urine storage tank of a UDDT before urine starts to accumulate there to increase the efficiency of the lactic acid fermentation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Nanocoating cellulose paper based microextraction combined with nanospray mass spectrometry for rapid and facile quantitation of ribonucleosides in human urine.

    Science.gov (United States)

    Wan, Lingzhong; Zhu, Haijing; Guan, Yafeng; Huang, Guangming

    2017-07-01

    A rapid and facile analytical method for quantification of ribonucleosides in human urine was developed by the combination of nanocoating cellulose paper based microextraction and nanoelectrospray ionization-tandem mass spectrometry (nESI-MS/MS). Cellulose paper used for microextraction was modified by nano-precision deposition of uniform ultrathin zirconia gel film using a sol-gel process. Due to the large surface area of the cellulose paper and the strong affinity between zirconia and the cis-diol compounds, the target analytes were selectively extracted from the complex matrix. Thus, the detection sensitivity was greatly improved. Typically, the nanocoating cellulose paper was immersed into the diluted urine for selective extraction of target analytes, then the extracted analytes were subjected to nESI-MS/MS detection. The whole analytical procedure could be completed within 10min. The method was evaluated by the determination of ribonucleosides (adenosine, cytidine, uridine, guanosine) in urine sample. The signal intensities of the ribonuclesides extracted by the nanocoating cellulose paper were greatly enhanced by 136-459-folds compared with the one of the unmodified cellulose paper based microextraction. The limits of detection (LODs) and the limits of quantification (LOQs) of the four ribonucleosides were in the range of 0.0136-1.258μgL -1 and 0.0454-4.194μgL -1 , respectively. The recoveries of the target nucleosides from spiked human urine were in the range of 75.64-103.49% with the relative standard deviations (RSDs) less than 9.36%. The results demonstrate the potential of the proposed method for rapid and facile determination of endogenous ribonucleosides in urine sample. Copyright © 2017. Published by Elsevier B.V.

  13. Normalization to specific gravity prior to analysis improves information recovery from high resolution mass spectrometry metabolomic profiles of human urine.

    Science.gov (United States)

    Edmands, William M B; Ferrari, Pietro; Scalbert, Augustin

    2014-11-04

    Extraction of meaningful biological information from urinary metabolomic profiles obtained by liquid-chromatography coupled to mass spectrometry (MS) necessitates the control of unwanted sources of variability associated with large differences in urine sample concentrations. Different methods of normalization either before analysis (preacquisition normalization) through dilution of urine samples to the lowest specific gravity measured by refractometry, or after analysis (postacquisition normalization) to urine volume, specific gravity and median fold change are compared for their capacity to recover lead metabolites for a potential future use as dietary biomarkers. Twenty-four urine samples of 19 subjects from the European Prospective Investigation into Cancer and nutrition (EPIC) cohort were selected based on their high and low/nonconsumption of six polyphenol-rich foods as assessed with a 24 h dietary recall. MS features selected on the basis of minimum discriminant selection criteria were related to each dietary item by means of orthogonal partial least-squares discriminant analysis models. Normalization methods ranked in the following decreasing order when comparing the number of total discriminant MS features recovered to that obtained in the absence of normalization: preacquisition normalization to specific gravity (4.2-fold), postacquisition normalization to specific gravity (2.3-fold), postacquisition median fold change normalization (1.8-fold increase), postacquisition normalization to urinary volume (0.79-fold). A preventative preacquisition normalization based on urine specific gravity was found to be superior to all curative postacquisition normalization methods tested for discovery of MS features discriminant of dietary intake in these urinary metabolomic datasets.

  14. Complete nutrient recovery from source-separated urine by nitrification and distillation.

    Science.gov (United States)

    Udert, K M; Wächter, M

    2012-02-01

    In this study we present a method to recover all nutrients from source-separated urine in a dry solid by combining biological nitrification with distillation. In a first process step, a membrane-aerated biofilm reactor was operated stably for more than 12 months, producing a nutrient solution with a pH between 6.2 and 7.0 (depending on the pH set-point), and an ammonium to nitrate ratio between 0.87 and 1.15 gN gN(-1). The maximum nitrification rate was 1.8 ± 0.3 gN m(-2) d(-1). Process stability was achieved by controlling the pH via the influent. In the second process step, real nitrified urine and synthetic solutions were concentrated in lab-scale distillation reactors. All nutrients were recovered in a dry powder except for some ammonia (less than 3% of total nitrogen). We estimate that the primary energy demand for a simple nitrification/distillation process is four to five times higher than removing nitrogen and phosphorus in a conventional wastewater treatment plant and producing the equivalent amount of phosphorus and nitrogen fertilizers. However, the primary energy demand can be reduced to values very close to conventional treatment, if 80% of the water is removed with reverse osmosis and distillation is operated with vapor compression. The ammonium nitrate content of the solid residue is below the limit at which stringent EU safety regulations for fertilizers come into effect; nevertheless, we propose some additional process steps that will increase the thermal stability of the solid product. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Changes in urination according to the sound of running water using a mobile phone application.

    Science.gov (United States)

    Kwon, Whi-An; Kim, Sung Han; Kim, Sohee; Joung, Jae Young; Chung, Jinsoo; Lee, Kang Hyun; Lee, Sang-Jin; Seo, Ho Kyung

    2015-01-01

    The sound of running water (SRW) has been effectively used for toilet training during toddlerhood. However, the effect of SRW on voiding functions in adult males with lower urinary tract symptoms (LUTS) has not been evaluated. To determine the effect of SRW on urination in male patients with LUTS, multiple voiding parameters of uroflowmetry with postvoid residual urine (PVR) were assessed according to the presence of SRW played by a mobile application. Eighteen consecutive male patients with LUTS were prospectively enrolled between March and April 2014. Uroflowmetry with PVR measured by a bladder scan was randomly performed once weekly for two consecutive weeks with and without SRW in a completely sealed room after pre-checked bladder volume was scanned to be more than 150 cc. SRW was played with river water sounds amongst relaxed melodies from a smartphone mobile application. The mean age of enrolled patients and their mean International Prostate Symptom Score (IPSS) were 58.9 ± 7.7 years (range: 46-70) and 13.1 ± 5.9, respectively. All patients had not been prescribed any medications, including alpha-blockers or anti-muscarinic agents, in the last 3 months. There was a significant increase in mean peak flow rate (PFR) with SRW in comparison to without SRW (15.7 mL/s vs. 12.3 mL/s, respectively, p = 0.0125). However, there were no differences in other uroflowmetric parameters, including PVR. The study showed that SRW from a mobile phone application may be helpful in facilitating voiding functions by increasing PFR in male LUTS patients.

  16. Leaching from municipal solid waste incineration residues

    Energy Technology Data Exchange (ETDEWEB)

    Hyks, J.

    2008-02-15

    Leaching of pollutants from Municipal Solid Waste Incineration (MSWI) residues has been investigated combining a range of laboratory leaching experiments with geochemical modeling. Special attention was paid to assessing the applicability of laboratory data for subsequent modeling with respect to presumed full-scale conditions; both sample pretreatment and actual influence of leaching conditions on the results of laboratory experiments were considered. It was shown that sample pretreatment may have large impact on leaching test data. In particular, a significant fraction of Pb was shown mobile during the washing of residues with water. In addition, drying of residues (i.e. slow oxidation) prior to leaching experiments increased the leaching of Cr significantly. Significant differences regarding the leaching behavior of individual elements with respect to (non)equilibrium conditions in column percolation experiments were observed in the study. As a result, three groups of elements were identified based on the predominant leaching control and the influence of (non)equilibrium on the results of the laboratory column experiments: I. Predominantly availability-controlled elements (e.g. Na, K, Cl) II. Solubility-controlled elements (e.g. Ca, S, Si, Al, Ba, and Zn) III. Complexation-controlled elements (e.g. Cu and Ni) With respect to the above groups it was suggested that results of laboratory column experiments can, with consideration, be used to estimate full-scale leaching of elements from Group I and II. However, in order to avoid large underestimations in the assessment of leaching from Group III, it is imperative to describe the time-dependent transport of dissolved organic carbon (DOC) in the tested system or to minimize the physical non-equilibrium during laboratory experiments (e.g. bigger column, slower flow velocity). Forward geochemical modeling was applied to simulate long-term release of elements from a MSWI air-pollution-control residue. Leaching of a

  17. Morphological characteristics of urine erythrocytes in children with erythrocyturia

    Directory of Open Access Journals (Sweden)

    V.A. Minakova

    2017-09-01

    Full Text Available Background. Nephropathies with erythrocyturia make up about 1/3 of all diseases of the kidneys and the urinary system, and they have some difficulties in differential diagnostics. Quite often, erythrocyturia is the only symptom of these diseases. In connection with this, determination of its origin is an important task in forming the correct diagnosis. Erythrocyturia in most diseases of the lower urinary tract is not accompanied by proteinuria or the presence of cylinders in the urine. The presence of proteinuria (more than 0.3 g/l or 1 g protein in urine per day, along with the appearance of erythrocytic cylinder in the urine sediment, raises suspicion in favor of glomerular or tubular diseases. Glomerular erythrocytes may be detected by means of urea concentration factor (UCF in the urinary sediment as a preliminary test for the determination of the erythrocyturia site. Erythrocytes that pass through the glomerular membrane have a changed form (dysmorphic. Determination of acanthocytes in the urine (ring-shaped erythrocytes with one or several bulges in the form of bubbles of different sizes and types is a more precise criterion of glomerular nephropathy than the presence of dysmorphic erythrocytes. The purpose of the study was to determine the morphological characteristics of urine erythrocytes in children with erythrocyturia, to improve the quality of differential diagnosis. Materials and methods. Determination of the morphological characteristics of urinary erythrocytes using UCF in 73 patients aged 1 to 18 years, of which 45 (61.6 % are patients with hematuric form of glomerulonephritis, 23 (31.5 % — with hereditary nephritis, and 5 (6.8 % — with dysmetabolic nephropathy. Detection of 50 to 80 % of dysmorphic erythrocytes in the urine sediment and finding in urine of more than 5 % of acanthocytes is a highly sensitive and specific diagnostic criterion for glomerular hematuria. Results. In children with a clinical diagnosis

  18. Producing progeny from endangered birds of prey: Treatment of urine-contaminated semen and a novel intramagnal insemination approach

    Science.gov (United States)

    Blanco, J.M.; Gee, G.F.; Wildt, D.E.; Donoghue, A.M.

    2002-01-01

    Wild raptors brought into an ex situ environment often have poor semen quality that is further compromised by urine contamination. Generally, it is believed that in birds, artificial insemination into the cloaca or caudal vagina of females requires large doses of high-quality spermatozoa to maximize fertility. In an effort to define and overcome some of the challenges associated with reproduction in wild raptors, the objectives of this study were to 1) evaluate the frequency, impact, and remediation of urine contamination in fresh ejaculates for the purpose of maintaining sperm motility and viability in vitro, and 2) develop a deep insemination method that allows low numbers of washed sperm to be placed directly into the magnum to increase the probability of producing fertilized eggs. The species evaluated include golden eagle (Aquila chrysoetos), imperial eagle (A. adalberti), Bonelli's eagle (Hiernaetus fasciatus), and peregrine, falcon (Falco peregrinus). Semen samples were collected and pooled by species, and a minimum of 25 pooled ejaculates per species were evaluated for urine contamination, pH, sperm viability, and sperm motility; the samples were either unwashed or washed in neutral (pH 7.0) or alkaline (pH 8.0) modified Lake's diluent. Female golden eagles and peregrine falcons were inseminated via transjunctional, intramagnal insemination with washed spermatozoa from urine-contaminated samples. Urine contamination occurred in 36.8 +/- 12.8% (mean +/- SEM) golden eagle, 43.1 +/- 9.1% imperial eagle, 28.7 +/- 16.1% Bonelli's eagle, and 48.2 +/- 17.3% peregrine falcon ejaculates. The pH in urine-contaminated semen samples ranged from 6.48 +/- 0.3 to 6.86 +/- 0.2, and in noncontaminated samples it ranged from from 7.17 +/- 0.1 to 7.56 +/- 0.1. Sperm viability and motility were reduced (P golden eagle chick hatched after intramagnal insemination. This study demonstrates that urine contamination, a common and lethal acidifier in manually collected raptor

  19. The potential for energy production from crop residues in Zimbabwe

    Energy Technology Data Exchange (ETDEWEB)

    Jingura, R.M.; Matengaifa, R. [School of Engineering Sciences and Technology, Chinhoyi University of Technology, P. Bag 7724, Chinhoyi (Zimbabwe)

    2008-12-15

    There is increasing interest in Zimbabwe in the use of renewable energy sources as a means of meeting the country's energy requirements. Biomass provides 47% of the gross energy consumption in Zimbabwe. Energy can be derived from various forms of biomass using various available conversion technologies. Crop residues constitute a large part of the biomass available from the country's agriculture-based economy. The potential for energy production of crop residues is examined using data such as estimates of the quantities of the residues and their energy content. The major crops considered are maize, sugarcane, cotton, soyabeans, groundnuts, wheat, sorghum, fruits and forestry plantations. Quantities of residues are estimated from crop yields by using conversion coefficients for the various crops. Long-term crop yields data from 1970 to 1999 were used. Total annual residue yields for crops, fruits and forestry plantations are 7.805 Mt, 378 kt and 3.05 Mt, respectively. The crops, fruits and forestry residues have energy potential of 81.5, 4.9 and 44.3 PJ per year, respectively. This represents about 44% of the gross energy consumption in Zimbabwe. The need to balance use of crop residues for both energy purposes and other purposes such as animal feeding and soil fertility improvement is also highlighted. (author)

  20. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan

    2013-08-31

    We present the results of the assessment of the intramolecular residue-residue contact predictions from 26 prediction groups participating in the 10th round of the CASP experiment. The most recently developed direct coupling analysis methods did not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i.e., prediction accuracy and the difference between the distribution of the predicted contacts and that of all pairs of residues in the target protein), as well as new measures, such as the Matthews correlation coefficient, the area under the precision-recall curve and the ranks of the first correctly and incorrectly predicted contact. We also evaluated the ability to detect interdomain contacts and tested whether the difficulty of predicting contacts depends upon the protein length and the depth of the family sequence alignment. The analyses were carried out on the target domains for which structural homologs did not exist or were difficult to identify. The evaluation was performed for all types of contacts (short, medium, and long-range), with emphasis placed on long-range contacts, i.e. those involving residues separated by at least 24 residues along the sequence. The assessment suggests that the best CASP10 contact prediction methods perform at approximately the same level, and comparably to those participating in CASP9.

  1. Performance of Copan WASP for Routine Urine Microbiology

    Science.gov (United States)

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  2. Role of Urine Drug Testing in the Current Opioid Epidemic.

    Science.gov (United States)

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  3. Elevated CXC chemokines in urine noninvasively discriminate OAB from UTI.

    Science.gov (United States)

    Tyagi, Pradeep; Tyagi, Vikas; Qu, Xianggui; Chuang, Yao Chi; Kuo, Hann-Chorng; Chancellor, Michael

    2016-09-01

    Overlapping symptoms of overactive bladder (OAB) and urinary tract infection (UTI) often complicate the diagnosis and contribute to overprescription of antibiotics. Inflammatory response is a shared characteristic of both UTI and OAB and here we hypothesized that molecular differences in inflammatory response seen in urine can help discriminate OAB from UTI. Subjects in the age range of (20-88 yr) of either sex were recruited for this urine analysis study. Urine specimens were available from 62 UTI patients with positive dipstick test before antibiotic treatment. Six of these patients also provided urine after completion of antibiotic treatment. Subjects in cohorts of OAB (n = 59) and asymptomatic controls (n = 26) were negative for dipstick test. Urinary chemokines were measured by MILLIPLEX MAP Human Cytokine/Chemokine Immunoassay and their association with UTI and OAB was determined by univariate and multivariate statistics. Significant elevation of CXCL-1, CXCL-8 (IL-8), and CXCL-10 together with reduced levels for a receptor antagonist of IL-1A (sIL-1RA) were seen in UTI relative to OAB and asymptomatic controls. Elevated CXCL-1 urine levels predicted UTI with odds ratio of 1.018 and showed a specificity of 80.77% and sensitivity of 59.68%. Postantibiotic treatment, reduction was seen in all CXC chemokines with a significant reduction for CXCL-10. Strong association of CXCL-1 and CXCL-10 for UTI over OAB indicates mechanistic differences in signaling pathways driving inflammation secondary of infection in UTI compared with a lack of infection in OAB. Urinary chemokines highlight molecular differences in the paracrine signaling driving the overlapping symptoms of UTI and OAB. Copyright © 2016 the American Physiological Society.

  4. Improvement and Validation of Weld Residual Stress Modelling Procedure

    International Nuclear Information System (INIS)

    Zang, Weilin; Gunnars, Jens; Dong, Pingsha; Hong, Jeong K.

    2009-06-01

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  5. Biogas systems for sisal and other agro-industrial residues

    Energy Technology Data Exchange (ETDEWEB)

    Jungersen, G [Danish Technological Inst., Section for Biotechnology, Taastrup (Denmark)

    1998-12-31

    Most of the East-African agro-industries are generating very large quantities of organic residues from production and processing of different crops. In the East-African Region the most important of these crops are: Sisal, Sugar, Coffee, Cashew nuts and Pineapple. In other 3. world countries, Palm oil and Cassava (Tapioca starch) processing are main producers of organic waste products. Moreover, large quantities of organic residues are generated from other food processing activities like breweries, consumption of bananas etc. The following pages give examples of setups and system designs of anaerobic treatment systems for some of the residues mentioned above. When considering anaerobic treatment of sisal residues, which constitutes the main agro-industrial biomass resource in Tanzania, two major issues should be considered: Optimal reactor set-up and performance; And optionally, potential methods for pre-treatment of fibre fraction in order to increase the methane yield. The sisal liquid residues are degraded very fast and efficiently in UASB systems. At COD loading rates less than 11 kg COD/m{sup 3} x day, the reduction in organic matter is more than 90% and methane yields obtained are between 373 and 377 ml CH{sub 4}/g COD reduced. The treatment of sisal solid residues in CSTR systems has been examined both at mesophilic (37 deg. C) and thermophilic temperatures (55 deg. C.). (EG)

  6. Biogas systems for sisal and other agro-industrial residues

    Energy Technology Data Exchange (ETDEWEB)

    Jungersen, G. [Danish Technological Inst., Section for Biotechnology, Taastrup (Denmark)

    1997-12-31

    Most of the East-African agro-industries are generating very large quantities of organic residues from production and processing of different crops. In the East-African Region the most important of these crops are: Sisal, Sugar, Coffee, Cashew nuts and Pineapple. In other 3. world countries, Palm oil and Cassava (Tapioca starch) processing are main producers of organic waste products. Moreover, large quantities of organic residues are generated from other food processing activities like breweries, consumption of bananas etc. The following pages give examples of setups and system designs of anaerobic treatment systems for some of the residues mentioned above. When considering anaerobic treatment of sisal residues, which constitutes the main agro-industrial biomass resource in Tanzania, two major issues should be considered: Optimal reactor set-up and performance; And optionally, potential methods for pre-treatment of fibre fraction in order to increase the methane yield. The sisal liquid residues are degraded very fast and efficiently in UASB systems. At COD loading rates less than 11 kg COD/m{sup 3} x day, the reduction in organic matter is more than 90% and methane yields obtained are between 373 and 377 ml CH{sub 4}/g COD reduced. The treatment of sisal solid residues in CSTR systems has been examined both at mesophilic (37 deg. C) and thermophilic temperatures (55 deg. C.). (EG)

  7. Improvement and Validation of Weld Residual Stress Modelling Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Weilin; Gunnars, Jens (Inspecta Technology AB, Stockholm (Sweden)); Dong, Pingsha; Hong, Jeong K. (Center for Welded Structures Research, Battelle, Columbus, OH (United States))

    2009-06-15

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  8. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery

    Science.gov (United States)

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2015-01-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies. PMID:25663845

  9. Relationship between ultrasonic Rayleigh waves and surface residual stress

    International Nuclear Information System (INIS)

    Adler, L.; Cook, K.V.; Dewey, B.R.; King, R.T.

    1977-01-01

    Local variations of Rayleigh (surface) circumferential ultrasonic wave velocity near a pipe-girth weld in large-diameter thin-wall type 316H stainless steel pipe were measured. The weldment was similar to those anticipated for the Liquid Metal Fast Breeder Reactor (LMFBR) piping systems. The residual stress distribution was estimated independently from shell theory for an elastic, infinite, thin shell with circumferential line loading. An upper bound on the magnitude of the residual stresses was estimated assuming the deformation of the shell was entirely elastic. The pattern of surface wave velocity variations matches the theoretical residual stress pattern closely. It is suggested that the monitoring of surface wave velocity variations might be used for characterizing residual stress patterns near critical welds in piping, aiding in design calculations, and for in-service monitoring of the state of stress of weldments

  10. Residual Resistance Data from Cavity Production Projects at Jefferson Lab

    International Nuclear Information System (INIS)

    Ciovati, Gianluigi; Geng, Rongli; Mammosser, John; Saunders, Jeffrey

    2010-01-01

    A fundamental limitation towards achieving high quality factors in superconducting radio-frequency cavities is the so-called residual resistance. Understanding and controlling the residual resistance has important implications towards improving the efficiency and reduce the operating cost of continuous wave superconducting linear accelerators. In this contribution we will report on the residual resistance values obtained from measurements of the quality factor of a large set of cavities, with resonant frequency between 805 MHz and 1.5 GHz, all of them processed and tested at Jefferson Lab. Surface treatments included both buffered chemical polishing and electropolishing. The results indicate an approximate value of the residual resistance of about 7-10 n Omega.

  11. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  12. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  13. Comparative Study of Seven Commercial Kits for Human DNA Extraction from Urine Samples Suitable for DNA Biomarker-Based Public Health Studies

    Science.gov (United States)

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.

    2014-01-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790

  14. Comparative study of seven commercial kits for human DNA extraction from urine samples suitable for DNA biomarker-based public health studies.

    Science.gov (United States)

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H C; De Keersmaecker, Sigrid C J

    2014-12-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at -20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies.

  15. Effect of the application of cattle urine with or without the nitrification inhibitor DCD, and dung on greenhouse gas emissions from a UK grassland soil.

    Science.gov (United States)

    Cardenas, L M; Misselbrook, T M; Hodgson, C; Donovan, N; Gilhespy, S; Smith, K A; Dhanoa, M S; Chadwick, D

    2016-11-01

    Emissions of nitrous oxide (N 2 O) from soils from grazed grasslands have large uncertainty due to the great spatial variability of excreta deposition, resulting in heterogeneous distribution of nutrients. The contribution of urine to the labile N pool, much larger than that from dung, is likely to be a major source of emissions so efforts to determine N 2 O emission factors (EFs) from urine and dung deposition are required to improve the inventory of greenhouse gases from agriculture. We investigated the effect of the application of cattle urine and dung at different times of the grazing season on N 2 O emissions from a grassland clay loam soil. Methane emissions were also quantified. We assessed the effect of a nitrification inhibitor, dicyandiamide (DCD), on N 2 O emissions from urine application and also included an artificial urine treatment. There were significant differences in N 2 O EFs between treatments in the spring (largest from urine and lowest from dung) but not in the summer and autumn applications. We also found that there was a significant effect of season (largest in spring) but not of treatment on the N 2 O EFs. The resulting EF values were 2.96, 0.56 and 0.11% of applied N for urine for spring, summer and autumn applications, respectively. The N 2 O EF values for dung were 0.14, 0.39 and 0.10% for spring, summer and autumn applications, respectively. The inhibitor was effective in reducing N 2 O emissions for the spring application only. Methane emissions were larger from the dung application but there were no significant differences between treatments across season of application.

  16. Natural levels of {sup 210}Po in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Frances, I.; Manjon, G.; Mantero, J.; Diaz, J. [Departament of Applied Phisic II, University of Seville, P.O. Box 41012 Seville (Spain); Garcia-Tenorio, R. [Departament of Applied Phisic II, University of Seville, P.O. Box 41012 Seville (Spain); National Accelerator Centre, P.O. Box 41092 Seville (Spain)

    2014-07-01

    Since the secret agent Alexander Litvinenko was murdered in 2006 by a {sup 210}Po lethal dose, presumably ingested, there is renovated interest on the toxicity of this radionuclide in humans. {sup 210}Po is a radioactive isotope naturally found in nature, mainly incorporated by humans via food and water ingestion, as well as inhaled through its progenitor, the {sup 222}Rn. The total amount of natural {sup 210}Po in the human body can vary from person to person depending on their lifestyle: dietary habits, drinking water source, place of residence (associated with exposure to {sup 222}Rn), etc- and therefore in the concentrations of this element to be found in urine. To analyze the influence of dietary habits on the amount of {sup 210}Po excreted in urine, two volunteers in Seville had a well-defined and time-varying diet for a month, following a daily collection of their urine and determination of the concentrations therein of this radionuclide. The results obtained and the conclusions derived from them form the core of this communication. {sup 210}Po determinations were performed daily in 200 ml aliquots of urine using the technique of high resolution alpha spectrometry. This has involved the application of a single radiochemical method for the concentration and isolation {sup 210}Po, followed by its auto-deposition on copper planchets for proper measure. Daily {sup 210}Po activity concentrations in voluntary urine analyzed during the month of study show high variability with a difference of up to an order of magnitude between maximum and minimum values obtained, and a clear dependence on the diet type followed in the various stages of the experiment. The lowest concentrations obtained are associated with a diet rich in carbohydrates and proteins 'terrestrial' (pork, beef,...), while the highest concentrations were obtained in the final phase of the experiment when the diet was enriched with presence of marine products in fair correspondence with the

  17. Residual stresses around Vickers indents

    International Nuclear Information System (INIS)

    Pajares, A.; Guiberteau, F.; Steinbrech, R.W.

    1995-01-01

    The residual stresses generated by Vickers indentation in brittle materials and their changes due to annealing and surface removal were studied in 4 mol% yttria partially stabilized zirconia (4Y-PSZ). Three experimental methods to gain information about the residual stress field were applied: (i) crack profile measurements based on serial sectioning, (ii) controlled crack propagation in post indentation bending tests and (iii) double indentation tests with smaller secondary indents located around a larger primary impression. Three zones of different residual stress behavior are deduced from the experiments. Beneath the impression a crack free spherical zone of high hydrostatic stresses exists. This core zone is followed by a transition regime where indentation cracks develop but still experience hydrostatic stresses. Finally, in an outward third zone, the crack contour is entirely governed by the tensile residual stress intensity (elastically deformed region). Annealing and surface removal reduce this crack driving stress intensity. The specific changes of the residual stresses due to the post indentation treatments are described and discussed in detail for the three zones

  18. Cellulosic ethanol production from agricultural residues in Nigeria

    International Nuclear Information System (INIS)

    Iye, Edward; Bilsborrow, Paul

    2013-01-01

    Nigeria′s Biofuels Policy introduced in 2007 mandates a 10% blend (E10) of bioethanol with gasoline. This study investigates the potential for the development of a cellulosic ethanol industry based on the availability of agricultural residues and models the number of commercial processing facilities that could be sited in the six Geo-political zones. The potential for cellulosic ethanol production from agricultural residues in Nigeria is 7556 km 3 per annum exceeding the mandate of 10% renewable fuel required and providing the potential for 12 large- and 11 medium-scale processing facilities based on the use of a single feedstock. Cassava and yam peelings provided in excess of 80% of the process residues available with enough feedstock to supply 10 large-scale facilities with a fairly even distribution across the zones. Sorghum straw, millet straw and maize stalks represented 75% of the potential resource available from field residues with the potential to supply 2 large- and 7 medium-scale processing facilities, all of which would be located in the north of the country. When a multi-feedstock approach is used, this provides the potential for either 29 large- or 58 medium-scale facilities based on outputs of 250 and 125 km 3 per annum respectively. - Highlights: • Nigeria′s Biofuels Policy mandates a 10% blend of bioethanol with gasoline. • Total bioethanol production from agricultural residues was 7556 km 3 per annum. • Process residues offer the greatest potential accounting for 62% of production. • Nigeria has the potential for 12 large- and 11 medium scale commercial. • The use of mixed feedstocks significantly increases the potential for production

  19. Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)

    Science.gov (United States)

    William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy

    2009-01-01

    Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...

  20. Urine Osmolality in Treatment-naïve HIV-positive Subjects in ...

    African Journals Online (AJOL)

    2017-03-01

    Mar 1, 2017 ... a significant association between urine osmolality and body mass index (BMI), creatinine clearance, as well as serum .... approved by the Ethics Research Committee of the hospital. With the help of a questionnaire, .... SD=standard deviation, SUOsm=spot urine osmolality,. 24UOsm=24-h urine osmolality, ...