WorldWideScience

Sample records for large diameter high

  1. Developing high coercivity in large diameter cobalt nanowire arrays

    Science.gov (United States)

    Montazer, A. H.; Ramazani, A.; Almasi Kashi, M.; Zavašnik, J.

    2016-11-01

    Regardless of the synthetic method, developing high magnetic coercivity in ferromagnetic nanowires (NWs) with large diameters has been a challenge over the past two decades. Here, we report on the synthesis of highly coercive cobalt NW arrays with diameters of 65 and 80 nm, which are embedded in porous anodic alumina templates with high-aspect-ratio pores. Using a modified electrochemical deposition method enabled us to reach room temperature coercivity and remanent ratio up to 3000 Oe and 0.70, respectively, for highly crystalline as-synthesized hcp cobalt NW arrays with a length of 8 μm. The first-order reversal curve (FORC) analysis showed the presence of both soft and hard magnetic phases along the length of the resulting NWs. To develop higher coercive fields, the length of the NWs was then gradually reduced in order from bottom to top, thereby reaching NW sections governed by the hard phase. Consequently, this resulted in record high coercivities of 4200 and 3850 Oe at NW diameters of 65 and 80 nm, respectively. In this case, the FORC diagrams confirmed a significant reduction in interactions between the magnetic phases of the remaining sections of NWs. At this stage, x-ray diffraction (XRD) and dark-field transmission electron microscopy analyses indicated the formation of highly crystalline bamboo-like sections along the [0 0 2] direction during a progressive pulse-controlled electrochemical growth of NW arrays under optimized parameters. Our results both provide new insights into the growth process, crystalline characteristics and magnetic phases along the length of large diameter NW arrays and, furthermore, develop the performance of pure 3d transition magnetic NWs.

  2. Characteristics of two-phase flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65401 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2016-12-15

    Two-phase flows in large diameter channels have a great deal of importance in a wide variety of industrial applications. Nuclear systems, petroleum refineries, and chemical processes make extensive use of larger systems. Flows in such channels have very different properties from flows in smaller channels which are typically used in experimental research. In this paper, the various differences between flows in large and small channels are highlighted using the results of previous experimental and analytical research. This review is followed by a review of recent experiments in and model development for flows in large diameter channels performed by the authors. The topics of these research efforts range from void fraction and interfacial area concentration measurement to flow regime identification and modeling, drift-flux modeling for high void fraction conditions, and evaluation of interfacial area transport models for large diameter channels.

  3. Guided proliferation and bone-forming functionality on highly ordered large diameter TiO2 nanotube arrays

    International Nuclear Information System (INIS)

    Zhang, Ruopeng; Wu, Hongliu; Ni, Jiahua; Zhao, Changli; Chen, Yifan; Zheng, Chengjunyi; Zhang, Xiaonong

    2015-01-01

    The significantly enhanced osteoblast adhesion, proliferation and alkaline phosphatase (ALP) activity were observed on TiO 2 nanotube surface in recent studies in which the scale of nanotube diameter was restricted under 100 nm. In this paper, a series of highly ordered TiO 2 nanotube arrays with larger diameters ranging from 150 nm to 470 nm were fabricated via high voltage anodization. The behaviors of MC3T3-E1 cells in response to the diameter-controlled TiO 2 nanotubes were investigated. A contrast between the trend of proliferation and the trend of cell elongation was observed. The highest cell elongation (nearly 10:1) and the lowest cell number were observed on the TiO 2 nanotube arrays with 150 nm diameter. While, the lowest cell elongation and highest cell number were achieved on the TiO 2 nanotube arrays with 470 nm diameter. Furthermore, the ALP activity peaked on the 150 nm diameter TiO 2 nanotube arrays and decreased dramatically with the increase of nanotube diameter. Thus a narrow range of diameter (100–200 nm) that could induce the greatest bone-forming activity is determined. It is expected that more delicate design of orthopedic implant with regional abduction of cell proliferation or bone forming could be achieved by controlling the diameter of TiO 2 nanotubes. - Highlights: • Improved anodization methods leading to more ordered large diameter TiO 2 nanotubes • Significantly enhanced ALP activity was observed on 150 nm diameter TiO 2 nanotubes. • The highest cell density was observed on 470 nm diameter TiO 2 nanotube arrays. • Similar cell response was observed on the amorphous and anatase phased nanotube surface

  4. Fabrication of large diameter alumino-silicate K+ sources

    International Nuclear Information System (INIS)

    Baca, D.; Chacon-Golcher, E.; Kwan, J.W.; Wu, J.K.

    2003-01-01

    Alumino-silicate K + sources have been used in HIF experiments for many years. For example the Neutralized Transport Expt. (NTX) and the High Current Transport Expt. (HCX) are now using this type of ion source with diameters of 2.54 cm and 10 cm respectively. These sources have demonstrated ion currents of 80 mA and 700 mA, for typical HIF pulse lengths of 5-10 (micro)s. The corresponding current density is ∼ 10-15 mA/cm 2 , but much higher current density has been observed using smaller size sources. Recently we have improved our fabrication techniques and, therefore, are able to reliably produce large diameter ion sources with high quality emitter surface without defects. This note provides a detailed description of the procedures employed in the fabrication process. The variables in the processing steps affecting surface quality, such as substrate porosity, powder size distribution, coating technique on large area concave surfaces, drying, and heat firing temperature have been investigated

  5. Moisture monitoring in large diameter boreholes

    International Nuclear Information System (INIS)

    Tyler, S.

    1985-01-01

    The results of both laboratory and field experiments indicate that the neutron moisture gauge traditionally used in soil physics experiments can be extended for use in large diameter (up to 15 cm) steel-cased boreholes with excellent results. This application will permit existing saturated zone monitoring wells to be used for unsaturated zone monitoring of recharge, redistribution and leak detection from waste disposal facilities. Its applicability to large diameter cased wells also gives the soil physicist and ground-water hydrologist and new set of monitoring points in the unsaturated zone to study recharge and aquifer properties. 6 refs., 6 figs., 2 tabs

  6. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  7. Two-phase flow structure in large diameter pipes

    International Nuclear Information System (INIS)

    Smith, T.R.; Schlegel, J.P.; Hibiki, T.; Ishii, M.

    2012-01-01

    Highlights: ► Local profiles of various quantities measured in large diameter pipe. ► Database for interfacial area in large pipes extended to churn-turbulent flow. ► Flow regime map confirms previous models for flow regime transitions. ► Data will be useful in developing interfacial area transport models for large pipes. - Abstract: Flow in large pipes is important in a wide variety of applications. In the nuclear industry in particular, understanding of flow in large diameter pipes is essential in predicting the behavior of reactor systems. This is especially true of natural circulation Boiling Water Reactor (BWR) designs, where a large-diameter chimney above the core provides the gravity head to drive circulation of the coolant through the reactor. The behavior of such reactors during transients and during normal operation will be predicted using advanced thermal–hydraulics analysis codes utilizing the two-fluid model. Essential to accurate two-fluid model calculations is reliable and accurate computation of the interfacial transfer terms. These interfacial transfer terms can be expressed as the product of one term describing the potential driving the transfer and a second term describing the available surface area for transfer, or interfacial area concentration. Currently, the interfacial area is predicted using flow regime dependent empirical correlations; however the interfacial area concentration is best computed through the use of the one-dimensional interfacial area transport equation (IATE). To facilitate the development of IATE source and sink term models in large-diameter pipes a fundamental understanding of the structure of the two-phase flow is essential. This understanding is improved through measurement of the local void fraction, interfacial area concentration and gas velocity profiles in pipes with diameters of 0.102 m and 0.152 m under a wide variety of flow conditions. Additionally, flow regime identification has been performed to

  8. STATE OF THE ART OF DRILLING LARGE DIAMETER BOREHOLES FOR DEPOSITION OF HIGH LEVEL WASTE AND SPENT NUCLEAR FUEL

    Directory of Open Access Journals (Sweden)

    Trpimir Kujundžić

    2012-07-01

    Full Text Available Deep geological disposal is internationally recognized as the safest and most sustainable option for the long-term management of high-level radioactive waste. Mainly, clay rock, salt rock and crystalline rock are being considered as possible host rocks. Different geological environment in different countries led to the various repository concepts. Main feature of the most matured repository concept is that canisters with spent nuclear fuel are emplaced in vertical or horizontal large diameter deposition holes. Drilling technology of the deposition holes depends on repository concept and geological and geomechanical characteristics of the rock. The deposition holes are mechanically excavated since drill & blast is not a possible method due to requirements on final geometry like surface roughness etc. Different methods of drilling large diameter boreholes for deposition of high-level waste and spent nuclear fuel are described. Comparison of methods is made considering performance and particularities in technology.

  9. Controlled growth of well-aligned carbon nanotubes with large diameters

    Science.gov (United States)

    Wang, Xianbao; Liu, Yunqi; Zhu, Daoben

    2001-06-01

    Well-aligned carbon nanotubes (CNTs) with large diameters (25-200 nm) were synthesized by pyrolysis of iron(II) phthalocyanine. The outer diameter up to 218.5 nm and the length of the well-aligned CNTs can be systematically controlled by varying the growth time. A tube-in-tube nano-structure with large and small diameters of 176 and 16.7 nm, respectively, was found. The grain sizes of the iron catalyst play an important role in controlling the CNT diameters. These results are of great importance to design new aligned CNT-based electron field emitters in the potential application of panel displays.

  10. Evaluation of technology for large- and small-diameter boreholes to characterize crystalline rock

    International Nuclear Information System (INIS)

    1985-05-01

    Testing methods that have been used in large- and small-diameter boreholes (152 and 76 mm [6 and 3 in.]) were evaluated on their ability to characterize crystalline rocks. The methods evaluated included in-hole geomechanical, geophysical, and geohydrologic techniques and associated laboratory core tests; specific emphasis was on techniques that might be used in a field characterization program involving a small number of deep (up to 1500 m [5000 ft]) boreholes. Each technique was evaluated with regard to its effectiveness and limitations, applicability to the acquisition of data for anticipated rock conditions, and adequacy for assessing the required rock/hydrologic characteristics. Many pertinent case histories that helped to assess applicability were reviewed. A principal objective of the evaluations was to assess whether the techniques would be equally useful in both large- and small-diameter boreholes. Of the techniques evaluated, most are suitable for use in both large- and small-diameter boreholes. Borehole logging, hydrologic testing, and core-testing techniques provide suitable results in both borehole diameters. Geomechanical testing techniques provide suitable data in smaller diameter boreholes and have been designed for application at primarily shallow depths. The results of this study will be of use to the Office of Crystalline Repository Development (OCRD) in determining to what degree it is appropriate to use drilling, sampling, and testing techniques in small-diameter boreholes as opposed to large-diameter methods, while at the same time collecting adequate data for characterizing crystalline rock environments for potential use as a high-level radioactive waste repository. Additionally, further developmental work and specific testing techniques are recommended

  11. Twentieth-century decline of large-diameter trees in Yosemite National Park, California, USA

    Science.gov (United States)

    Lutz, J.A.; van Wagtendonk, J.W.; Franklin, J.F.

    2009-01-01

    Studies of forest change in western North America often focus on increased densities of small-diameter trees rather than on changes in the large tree component. Large trees generally have lower rates of mortality than small trees and are more resilient to climate change, but these assumptions have rarely been examined in long-term studies. We combined data from 655 historical (1932-1936) and 210 modern (1988-1999) vegetation plots to examine changes in density of large-diameter trees in Yosemite National Park (3027 km2). We tested the assumption of stability for large-diameter trees, as both individual species and communities of large-diameter trees. Between the 1930s and 1990s, large-diameter tree density in Yosemite declined 24%. Although the decrease was apparent in all forest types, declines were greatest in subalpine and upper montane forests (57.0% of park area), and least in lower montane forests (15.3% of park area). Large-diameter tree densities of 11 species declined while only 3 species increased. Four general patterns emerged: (1) Pinus albicaulis, Quercus chrysolepis, and Quercus kelloggii had increases in density of large-diameter trees occur throughout their ranges; (2) Pinus jeffreyi, Pinus lambertiana, and Pinus ponderosa, had disproportionately larger decreases in large-diameter tree densities in lower-elevation portions of their ranges; (3) Abies concolor and Pinus contorta, had approximately uniform decreases in large-diameter trees throughout their elevational ranges; and (4) Abies magnifica, Calocedrus decurrens, Juniperus occidentalis, Pinus monticola, Pseudotsuga menziesii, and Tsuga mertensiana displayed little or no change in large-diameter tree densities. In Pinus ponderosa-Calocedrus decurrens forests, modern large-diameter tree densities were equivalent whether or not plots had burned since 1936. However, in unburned plots, the large-diameter trees were predominantly A. concolor, C. decurrens, and Q. chrysolepis, whereas P. ponderosa

  12. Ecological Importance of Large-Diameter Trees in a Temperate Mixed-Conifer Forest

    Science.gov (United States)

    Lutz, James A.; Larson, Andrew J.; Swanson, Mark E.; Freund, James A.

    2012-01-01

    Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. Although both scaling theory and competition theory make predictions about the relative composition and spatial patterns of large-diameter trees compared to smaller diameter trees, these predictions are rarely tested. We established a 25.6 ha permanent plot within which we tagged and mapped all trees ≥1 cm dbh, all snags ≥10 cm dbh, and all shrub patches ≥2 m2. We sampled downed woody debris, litter, and duff with line intercept transects. Aboveground live biomass of the 23 woody species was 507.9 Mg/ha, of which 503.8 Mg/ha was trees (SD = 114.3 Mg/ha) and 4.1 Mg/ha was shrubs. Aboveground live and dead biomass was 652.0 Mg/ha. Large-diameter trees comprised 1.4% of individuals but 49.4% of biomass, with biomass dominated by Abies concolor and Pinus lambertiana (93.0% of tree biomass). The large-diameter component dominated the biomass of snags (59.5%) and contributed significantly to that of woody debris (36.6%). Traditional scaling theory was not a good model for either the relationship between tree radii and tree abundance or tree biomass. Spatial patterning of large-diameter trees of the three most abundant species differed from that of small-diameter conspecifics. For A. concolor and P. lambertiana, as well as all trees pooled, large-diameter and small-diameter trees were spatially segregated through inter-tree distances trees and spatial relationships between large-diameter and small-diameter trees. Long-term observations may reveal regulation of forest biomass and spatial structure by fire, wind, pathogens, and insects in Sierra Nevada mixed-conifer forests. Sustaining ecosystem functions such as carbon storage or provision of specialist species habitat will likely require different management strategies when the functions are performed primarily by a few large trees as opposed to many smaller trees. PMID:22567132

  13. Gamma ray scanning as troubleshooting tool for unusual and large diameter refinery vacuum columns

    International Nuclear Information System (INIS)

    Sarkar, T.K.; Chawla, R.; Banik, S.; Chopra, S.J.; Singh, G.; Pant, H.J.; Sreeramakrishnan, P.; Dhar, D.C.; Pushpangathan, P.N.; Sharma, V.K.

    1997-01-01

    Gamma scanning of trayed and packed columns is widely used to obtain density profiles and identify on-line problems such as: damaged tray or packing, foaming, flooding, maldistribution, weeping and entrainment, etc. However, scanning of large diameter tray or packed columns requires expertise in handling high intensity gamma sources along with thorough understanding of distillation engineering. Engineers India Limited and the Bhabha Atomic Research Centre undertook scanning of two such large diameter (8.4 m and 7.4 m) trayed and packed refinery vacuum distillation columns and successfully diagnosed the problems and suggested remedial actions. Radiography testing of small diameter columns can be used to confirm gamma scanning results. One such example for ammonia separator column is given

  14. Numerical Modelling of Large-Diameter Steel Piles at Horns Rev

    DEFF Research Database (Denmark)

    Augustesen, Anders Hust; Brødbæk, K. T.; Møller, M.

    2009-01-01

    Today large-diameter monopiles are the most common foundation type used for large offshore wind farms. This paper aims to investigate the behaviour of monopiles under monotonic loading taking the interaction between the pile and the subsoil into account. Focus is paid to a monopile used as founda......Today large-diameter monopiles are the most common foundation type used for large offshore wind farms. This paper aims to investigate the behaviour of monopiles under monotonic loading taking the interaction between the pile and the subsoil into account. Focus is paid to a monopile used...... as foundation for a wind turbine at Horns Rev located in the Danish sector of the North Sea. The outer diameter of the pile is 4 m and the subsoil at the location consists primarily of sand. The behaviour of the pile is investigated under realistic loading conditions by means of a traditional Winkler...

  15. Load-bearing Characters Analysis of Large Diameter Rock-Socketed Filling Piles Based on Self-Balanced Method

    Science.gov (United States)

    tongqing, Wu; liang, Li; xinjian, Liu; Xu, nianchun; Tian, Mao

    2018-03-01

    Self-balanced method is carried out on the large diameter rock-socketed filling piles of high-pile wharf at Inland River, to explore the distribution laws of load-displacement curve, pile internal force, pile tip friction resistance and pile side friction resistance under load force. The results showed that: the tip resistance of S1 and S2 test piles accounted for 53.4% and 53.6% of the pile bearing capacity, respectively, while the total side friction resistance accounted for 46.6% and 46.4% of the pile bearing capacity, respectively; both the pile tip friction resistance and pile side friction resistance can be fully played, and reach to the design requirements. The reasonability of large diameter rock-socketed filling design is verified through test analysis, which can provide basis for the optimization of high-pile wharf structural type, thus reducing the wharf project cost, and also providing reference for the similar large diameter rock-socketed filling piles of high-pile wharf at Inland River.

  16. Wall thinning inspection technique for large-diameter piping using guided wave

    International Nuclear Information System (INIS)

    Miki, Masahiro; Nagashima, Yoshiaki; Endou, Masao; Kodaira, Kojiro; Maniwa, Kazuhiko

    2009-01-01

    Guided wave inspection technique is effective for detecting defects like corrosion in piping, because it can perform long range inspection. It is possible to expect this inspection as a method that leads to the decrease of the inspection process and its cost, because the incidental work can be reduced. Especially, the contraction effect of the inspection work is extensive in large-diameter piping inspection. In this paper, we introduce the guided wave inspection system to large-diameter piping. The feature is a guided wave sensor that can freely transform according to the curvature of inspection object, and portable inspection equipment. We discuss the result of detection examination for artificial wall-thinning in large-diameter piping using this system. (author)

  17. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    is developed for slender piles with diameters up to approximately 2.0 m. Hence, the method is not validated for piles with diameters of 4–6 m. The aim of the paper is to extend the p-y curve method to large-diameter non-slender piles in sand by considering the effects of the pile diameter on the soil-pile...... interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  18. Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes

    Directory of Open Access Journals (Sweden)

    M. El Nakla

    2013-01-01

    Full Text Available The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.

  19. Slug Flow Analysis in Vertical Large Diameter Pipes

    Science.gov (United States)

    Roullier, David

    The existence of slug flow in vertical co-current two-phase flow is studied experimentally and theoretically. The existence of slug flow in vertical direction implies the presence of Taylor bubbles separated by hydraulically sealed liquid slugs. Previous experimental studies such as Ombere-Ayari and Azzopardi (2007) showed the evidence of the non-existence of Taylor bubbles for extensive experimental conditions. Models developed to predict experimental behavior [Kocamustafaogullari et al. (1984), Jayanti and Hewitt. (1990) and Kjoolas et al. (2017)] suggest that Taylor bubbles may disappear at large diameters and high velocities. A 73-ft tall and 101.6-mm internal diameter test facility was used to conduct the experiments allowing holdup and pressure drop measurements at large L/D. Superficial liquid and gas velocities varied from 0.05-m/s to 0.2 m/s and 0.07 m/s to 7.5 m/s, respectively. Test section pressure varied from 38 psia to 84 psia. Gas compressibility effect was greatly reduced at 84 psia. The experimental program allowed to observe the flow patterns for flowing conditions near critical conditions predicted by previous models (air-water, 1016 mm ID, low mixture velocities). Flow patterns were observed in detail using wire-mesh sensor measurements. Slug-flow was observed for a narrow range of experimental conditions at low velocities. Churn-slug and churn-annular flows were observed for most of the experimental data-points. Cap-bubble flow was observed instead of bubbly flow at low vSg. Wire-mesh measurements showed that the liquid has a tendency to remain near to the walls. The standard deviation of radial holdup profile correlates to the flow pattern observed. For churn-slug flow, the profile is convex with a single maximum near the pipe center while it exhibits a concave shape with two symmetric maxima close to the wall for churn-annular flow. The translational velocity was measured by two consecutive wire-mesh sensor crosscorrelation. The results show

  20. 78 FR 60897 - Certain Welded Large Diameter Line Pipe From Japan

    Science.gov (United States)

    2013-10-02

    ... Diameter Line Pipe From Japan Determination On the basis of the record \\1\\ developed in the subject five... order on certain welded large diameter line pipe from Japan would likely to lead to continuation or... Line Pipe from Japan: Investigation No. 731-TA-919 (Second Review). By order of the Commission. Issued...

  1. Large diameter interseam boreholes: their usage to improve underground environments

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, A.J. (Nottingham University, Nottingham (United Kingdom). Dept. of Mineral Resources Engineering)

    1993-07-01

    Development of drilling techniques for larger diameter holes over the last fifteen years has indicated their considerable potential to assist with quickly improving environmental facilities and services to high output coal faces. In Nottinghamshire, as well as in several other regions, mines have utilised interseam boreholes, fully lined, to improve inbye air flows with subsequent reduction of face temperatures, dust and firedamp levels. Some further holes have additionally been adapted quickly to increase firedamp drainage capacities and also to improve service facilities such as compressed air, electrical power and water, and access. A wide range of borehole sizes are employed, ranging from 0.35 m, with integral steel lining, up to a maximum of 2.5 m in diameter, fully concrete lined. The Nottinghamshire Group Sinking and Tunnelling Engineer provides a full range of drilling facilities. The most popular large diameter holes with a potential of 1.8 m in diameter, over 200 m in vertical depth, employs a Robins, type 23R, raise borer which has been in use up and down the country since 1977. A Fosroc CGR10 type, techgrout is applied after boring is completed to provide the essential smooth lining. The application of this lining utilises a special rubber former developed locally, essentially knitting strata cracks, beddings and any local overbreak of the holes. The former or 'sausage' is used in a similar manner to correct and repair boreholes which have been in use for some time. 4 refs., 6 figs., 1 tab.

  2. Effect of high-pressure homogenization preparation on mean globule size and large-diameter tail of oil-in-water injectable emulsions.

    Science.gov (United States)

    Peng, Jie; Dong, Wu-Jun; Li, Ling; Xu, Jia-Ming; Jin, Du-Jia; Xia, Xue-Jun; Liu, Yu-Ling

    2015-12-01

    The effect of different high pressure homogenization energy input parameters on mean diameter droplet size (MDS) and droplets with > 5 μm of lipid injectable emulsions were evaluated. All emulsions were prepared at different water bath temperatures or at different rotation speeds and rotor-stator system times, and using different homogenization pressures and numbers of high-pressure system recirculations. The MDS and polydispersity index (PI) value of the emulsions were determined using the dynamic light scattering (DLS) method, and large-diameter tail assessments were performed using the light-obscuration/single particle optical sensing (LO/SPOS) method. Using 1000 bar homogenization pressure and seven recirculations, the energy input parameters related to the rotor-stator system will not have an effect on the final particle size results. When rotor-stator system energy input parameters are fixed, homogenization pressure and recirculation will affect mean particle size and large diameter droplet. Particle size will decrease with increasing homogenization pressure from 400 bar to 1300 bar when homogenization recirculation is fixed; when the homogenization pressure is fixed at 1000 bar, the particle size of both MDS and percent of fat droplets exceeding 5 μm (PFAT 5 ) will decrease with increasing homogenization recirculations, MDS dropped to 173 nm after five cycles and maintained this level, volume-weighted PFAT 5 will drop to 0.038% after three cycles, so the "plateau" of MDS will come up later than that of PFAT 5 , and the optimal particle size is produced when both of them remained at plateau. Excess homogenization recirculation such as nine times under the 1000 bar may lead to PFAT 5 increase to 0.060% rather than a decrease; therefore, the high-pressure homogenization procedure is the key factor affecting the particle size distribution of emulsions. Varying storage conditions (4-25°C) also influenced particle size, especially the PFAT 5 . Copyright

  3. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  4. Interfacial area concentration in gas–liquid bubbly to churn flow regimes in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    Highlights: • A systematic method to predict interfacial area concentration (IAC) is presented. • A correlation for group 1 bubble void fraction is proposed. • Correlations of IAC and bubble diameter are developed for group 1 bubbles. • Correlations of IAC and bubble diameter are developed for group 2 bubbles. • The newly-developed two-group IAC model compares well with collected databases. - Abstract: This study performed a survey on existing correlations for interfacial area concentration (IAC) prediction and collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes. Although some of these existing correlations were developed by partly using the IAC databases taken in the low-void-fraction two-phase flows in large diameter pipes, no correlation can satisfactorily predict the IAC in the two-phase flows changing from bubbly, cap bubbly to churn flow in the collected database of large diameter pipes. So this study presented a systematic way to predict the IAC for the bubbly-to-churn flows in large diameter pipes by categorizing bubbles into two groups (group 1: spherical or distorted bubble, group 2: cap bubble). A correlation was developed to predict the group 1 void fraction by using the void fraction for all bubble. The group 1 bubble IAC and bubble diameter were modeled by using the key parameters such as group 1 void fraction and bubble Reynolds number based on the analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. The correlations of IAC and bubble diameter for group 2 cap bubbles were developed by taking into account the characteristics of the representative bubbles among the group 2 bubbles and the comparison between a newly-derived drift velocity correlation for large diameter pipes and the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes. The predictions from the newly

  5. Film behaviour of vertical gas-liquid flow in a large diameter pipe

    OpenAIRE

    Zangana, Mohammed Haseeb Sedeeq

    2011-01-01

    Gas-liquid flow commonly occurs in oil and gas production and processing system. Large diameter vertical pipes can reduce pressure drops and so minimize operating costs. However, there is a need for research on two-phase flow in large diameter pipes to provide confidence to designers of equipments such as deep water risers. In this study a number of experimental campaigns were carried out to measure pressure drop, liquid film thickness and wall shear in 127mm vertical pipe. Total pressur...

  6. Problems of cleaning the large diameter sections of deep wells

    Energy Technology Data Exchange (ETDEWEB)

    Patsch, F; Gilicz, B

    1966-01-01

    In drilling deep wells, great importance is being given to the problem of cutting removal from the hole bottom of sections drilled by large diameter bits. The length of borehole sections drilled by 12-1/4-in. and larger bits has been more than doubled in Hungary in the course of the past 4 years. When the drilling fluid jet is struck against the borehole bottom, pressure waves are brought about which take on a crossed flow pattern and result in a retardation of cleaning of the well bottom, particularly in the case of larger bottom surfaces. In large diameter boreholes, the cleaning efficiency is being achieved by full utilization of the pump power and increased pump delivery. Friction losses in drill pipes are being reduced by using 6-in. XH pipes.

  7. Production of a large diameter ECR plasma with low electron temperature

    International Nuclear Information System (INIS)

    Koga, Mayuko; Hishikawa, Yasuhiro; Tsuchiya, Hayato; Kawai, Yoshinobu

    2006-01-01

    A large diameter plasma over 300 mm in diameter is produced by electron cyclotron resonance (ECR) discharges using a cylindrical vacuum chamber of 400 mm in inner diameter. It is found that the plasma uniformity is improved by adding the nitrogen gas to pure Ar plasma. The electron temperature is decreased by adding the nitrogen gas. It is considered that the electron energy is absorbed in the vibrational energy of nitrogen molecules and the electron temperature decreases. Therefore, the adjunction of the nitrogen gas is considered to be effective for producing uniform and low electron temperature plasma

  8. Design method of large-diameter rock-socketed pile with steel casing

    Science.gov (United States)

    Liu, Ming-wei; Fang, Fang; Liang, Yue

    2018-02-01

    There is a lack of the design and calculation method of large-diameter rock-socketed pile with steel casing. Combined with the “twelfth five-year plan” of the National Science & Technology Pillar Program of China about “Key technologies on the ports and wharfs constructions of the mountain canalization channels”, this paper put forward the structured design requirements of concrete, steel bar distribution and steel casing, and a checking calculation method of the bearing capacity of the normal section of the pile and the maximum crack width at the bottom of the steel casing. The design method will have some degree of guiding significance for the design of large-diameter rock-socketed pile with steel casing.

  9. Modern methods of drilling wells by large diameter bits and possible fields of application

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, W

    1970-04-01

    For the needs of up-to-date mining in construction of shafts and mining installations, large diameter wells are often used. In the near future, application of this type of well will be of great importance in the oil industry for stimulation of oil and gas recovery by atomic explosion. Such wells can be used for mineral extraction from subsea and other accessible deposits. The presented state of drilling techniques and technology by large diameter bits is described and similarities and differences with deep-well drilling are pointed out. Some economical data indicate the advantage of drilling by large-diameter bits in comparison with standard methods of construction of shafts and mining installations.

  10. Thin-walled large-diameter zirconium alloy tubes in CANDU reactors

    International Nuclear Information System (INIS)

    Price, E.G.; Richinson, P.J.

    1978-08-01

    The requirements of the thin-walled large-diameter Zircaloy-2 tubing used in CANDU reactors are reviewed. Strength, residual stress patterns, texture and prior deformation contribute to the stability of these tubes. The extent to which the present manufacturing route meets these requirements is discussed. (author)

  11. Experiment on a large-diameter plasma-filled backward-wave oscillator

    International Nuclear Information System (INIS)

    Ogura, K.; Minami, K.; Kurashina, K.I.; Kim, W.; Watanabe, T.; Ishii, K.; Sugito, S.

    1995-01-01

    A large-diameter plasma-filled backward-wave oscillator (BWO) is investigated experimentally. The parameters of slow wave structure are chosen so that the oscillation frequency is about 20GHz at 60keV beam energy. Plasma is produced by the beam and has favorable effects for beam propagation and Cerenkov oscillations. The output power of the BWO with plasma is observed to be three to six times that of vacuum BWO. The power level is several kilowatts and the efficiency is about 0.01%. For Cerenkov oscillations of a large-diameter BWO, the beam energy mainly determines the starting conditions for oscillation. The output power is strongly enhanced when the guiding magnetic field approaches the fundamental electron cyclotron resonance. This mechanism is closely related to the anomalous Doppler cyclotron resonance. The maximum power of 480kW with an efficiency of 5% is achieved even for a relatively low beam energy of 60keV. ((orig.))

  12. Centrifuge modelling of large diameter pile in sand subject to lateral loading

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    and cyclic behaviour of large diameter rigid piles in dry sand by use of physical modelling. The physical modelling has been carried out at Department of Civil Engineering at the Danish Technical University (DTU.BYG), in the period from 2005 to 2009. The main centrifuge facilities, and especially...... the equipment for lateral load tests were at the start of the research in 2005 outdated and a major part of the work with the geotechnical centrifuge included renovation and upgrading of the facilities. The research with respect to testing of large diameter piles included:  Construction of equipment...... with embedment lengths of 6, 8 and 10 times the diameter. The tests have been carried out with a load eccentricity of 2.5 m to 6.5 m above the sand surface. The present report includes a description of the centrifuge facilities, applied test procedure and equipment along with presentation of the obtained results....

  13. Two-group interfacial area concentration correlations of two-phase flows in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    The reliable empirical correlations and models are one of the important ways to predict the interfacial area concentration (IAC) in two-phase flows. However, up to now, no correlation or model is available for the prediction of the IAC in the two-phase flows in large diameter pipes. This study collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes and presented a systematic way to predict the IAC for two-phase flows from bubbly, cap-bubbly to churn flow in large diameter pipes by categorizing bubbles into two groups (group-1: spherical and distorted bubble, group-2: cap bubble). Correlations were developed to predict the group-1 void fraction from the void fraction of all bubble. The IAC contribution from group-1 bubbles was modeled by using the dominant parameters of group-1 bubble void fraction and Reynolds number based on the parameter-dependent analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. A new drift velocity correlation for two-phase flow with large cap bubbles in large diameter pipes was derived in this study. By comparing the newly-derived drift velocity correlation with the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes and using the characteristics of the representative bubbles among the group 2 bubbles, we developed the model of IAC and bubble size for group 2 cap bubbles. The developed models for estimating the IAC are compared with the entire collected database. A reasonable agreement was obtained with average relative errors of ±28.1%, ±54.4% and ±29.6% for group 1, group 2 and all bubbles respectively. (author)

  14. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of the diameter, depth and soil strength, and increase of each these will give an increase in stiffness. • Cyclic response of a lateral loaded pile is depended on the characteristics of the cyclic load. Behaviour of a monopile is a classic soil-structure interaction problem depending on the pile stiffness....... The target is to improve the use of monopiles as preferred support structure beyond the current limit at a water depth of 30 m. Design of foundations for wind turbines has a large focus on the stiffness of the combined structure, turbine-tower-foundation, which has an influence on the environmental loads...... initial response and a higher ultimate capacity. The initial stiffness of the soil-structure interaction measured in the centrifuge tests, equivalent to initial stiffness of p-y curves, shows a dependency of depth and diameter. Control issues in relation to cyclic tests have resulted in tests...

  15. A combination of permanent magnet and magnetic coil for a large diameter ion source

    International Nuclear Information System (INIS)

    Uramoto, Joshin; Kubota, Yusuke; Miyahara, Akira.

    1980-02-01

    A large diameter ion source for fast neutral beam injection is designed under a magnetic field (we call ''Uramoto Field'') composed of a circular ferrite permanent magnet and a usual coreless magnetic coil. As the magnetic filed is reduced abruptly in a discharge anode, an ion source with a uniform ion current density over a large diameter is produced easily without a ''button'' of ORNL duoPIGatron type ion source (a floating electrode to diffuse an axial plasma flow radially). (author)

  16. Modified distribution parameter for churn-turbulent flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: jschlege@purdue.edu; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-10-15

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction.

  17. Modified distribution parameter for churn-turbulent flows in large diameter channels

    International Nuclear Information System (INIS)

    Schlegel, J.P.; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-01-01

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction

  18. An αII Spectrin-Based Cytoskeleton Protects Large-Diameter Myelinated Axons from Degeneration.

    Science.gov (United States)

    Huang, Claire Yu-Mei; Zhang, Chuansheng; Zollinger, Daniel R; Leterrier, Christophe; Rasband, Matthew N

    2017-11-22

    Axons must withstand mechanical forces, including tension, torsion, and compression. Spectrins and actin form a periodic cytoskeleton proposed to protect axons against these forces. However, because spectrins also participate in assembly of axon initial segments (AISs) and nodes of Ranvier, it is difficult to uncouple their roles in maintaining axon integrity from their functions at AIS and nodes. To overcome this problem and to determine the importance of spectrin cytoskeletons for axon integrity, we generated mice with αII spectrin-deficient peripheral sensory neurons. The axons of these neurons are very long and exposed to the mechanical forces associated with limb movement; most lack an AIS, and some are unmyelinated and have no nodes. We analyzed αII spectrin-deficient mice of both sexes and found that, in myelinated axons, αII spectrin forms a periodic cytoskeleton with βIV and βII spectrin at nodes of Ranvier and paranodes, respectively, but that loss of αII spectrin disrupts this organization. Avil-cre;Sptan1 f/f mice have reduced numbers of nodes, disrupted paranodal junctions, and mislocalized Kv1 K + channels. We show that the density of nodal βIV spectrin is constant among axons, but the density of nodal αII spectrin increases with axon diameter. Remarkably, Avil-cre;Sptan1 f/f mice have intact nociception and small-diameter axons, but severe ataxia due to preferential degeneration of large-diameter myelinated axons. Our results suggest that nodal αII spectrin helps resist the mechanical forces experienced by large-diameter axons, and that αII spectrin-dependent cytoskeletons are also required for assembly of nodes of Ranvier. SIGNIFICANCE STATEMENT A periodic axonal cytoskeleton consisting of actin and spectrin has been proposed to help axons resist the mechanical forces to which they are exposed (e.g., compression, torsion, and stretch). However, until now, no vertebrate animal model has tested the requirement of the spectrin cytoskeleton in

  19. Dynamics of large-diameter water pipes in hydroelectric power plants

    Science.gov (United States)

    Pavić, G.; Chevillotte, F.; Heraud, J.

    2017-04-01

    An outline is made of physical behaviour of water - filled large pipes. The fluid-wall coupling, the key factor governing the pipe dynamics, is discussed in some detail. Different circumferential pipe modes and the associated cut-on frequencies are addressed from a theoretical as well as practical point of view. Major attention is paid to the breathing mode in view of its importance regarding main dynamic phenomena, such as water hammer. Selected measurement results done at EDF are presented to demonstrate how an external, non-intrusive sensor can detect pressure pulsations of the breathing mode in a pressure pipe. Differences in the pressure measurement using intrusive and non-intrusive sensors reveal the full complexity of large-diameter pipe dynamics.

  20. Theoretical analysis and experimental study on breakaway torque of large-diameter magnetic liquid seal at low temperature

    Science.gov (United States)

    Zhang, Haina; Li, Decai; Wang, Qinglei; Zhang, Zhili

    2013-07-01

    The existing researches of the magnetic liquid rotation seal have been mainly oriented to the seal at normal temperature and the seal with the smaller shaft diameter less than 100 mm. However, the large-diameter magnetic liquid rotation seal at low temperature has not been reported both in theory and in application up to now. A key factor restricting the application of the large-diameter magnetic liquid rotation seal at low temperature is the high breakaway torque. In this paper, the factors that influence the breakaway torque including the number of seal stages, the injected quantity of magnetic liquid and the standing time at normal temperature are studied. Two kinds of magnetic liquid with variable content of large particles are prepared first, and a seal feedthrough with 140 mm shaft diameter is used in the experiments. All experiments are carried out in a low temperature chamber with a temperature range from 200°C to -100°C. Different numbers of seal stages are tested under the same condition to study the relation between the breakaway torque and the number of seal stages. Variable quantity of magnetic liquid is injected in the seal gap to get the relation curve of the breakaway torque and the injecting quantity of magnetic liquid. In the experiment for studying the relation between the breakaway torque and the standing time at the normal temperature, the seal feedtrough is laid at normal temperature for different period of time before it is put in the low temperature chamber. The experimental results show that the breakaway torque is proportional to the number of seal stages, the injected quantity of magnetic liquid and the standing time at the normal temperature. Meanwhile, the experimental results are analyzed and the torque formula of magnetic liquid rotation seal at low temperature is deduced from the Navier-Stokes equation on the base of the model of magnetic liquid rotation seal. The presented research can make wider application of the magnetic liquid

  1. Development of three-dimensional phasic-velocity distribution measurement in a large-diameter pipe

    International Nuclear Information System (INIS)

    Kanai, Taizo; Furuya, Masahiro; Arai, Takahiro; Shirakawa, Kenetsu

    2011-01-01

    A wire-mesh sensor (WMS) can acquire a void fraction distribution at a high temporal and spatial resolution and also estimate the velocity of a vertical rising flow by investigating the signal time-delay of the upstream WMS relative to downstream. Previously, one-dimensional velocity was estimated by using the same point of each WMS at a temporal resolution of 1.0 - 5.0 s. The authors propose to extend this time series analysis to estimate the multi-dimensional velocity profile via cross-correlation analysis between a point of upstream WMS and multiple points downstream. Bubbles behave in various ways according to size, which is used to classify them into certain groups via wavelet analysis before cross-correlation analysis. This method was verified by air-water straight and swirl flows within a large-diameter vertical pipe. The results revealed that for the rising straight and swirl flows, large scale bubbles tend to move to the center, while the small bubble is pushed to the outside or sucked into the space where the large bubbles existed. Moreover, it is found that this method can estimate the rotational component of velocity of the swirl flow as well as measuring the multi-dimensional velocity vector at high temporal resolutions of 0.2s. (author)

  2. Multiaxial loading of large-diameter, thin-walled tube rock specimens

    International Nuclear Information System (INIS)

    Hecker, S.S.; Petrovic, J.J.

    1981-01-01

    A large-scale mechanical testing facility permits previously impossible thin-walled tube multiaxial loading experiments on rock materials. Constraints are removed regarding tube wall thickness in relation to rock microstructural features and tube diameter as well as test machine load capacity. Thin-walled tube studies clarify the influence of intermediate principal stress sigma 2 on rock fracture and help define a realistic rock fracture criterion for all multiaxial stressing situations. By comparing results of thin-walled and thick-walled tube fracture investigations, effects of stress gradients can be established. Finally, influence of stress path on rock fracture, an area largely ignored in current rock failure criteria, can be examined in detail using controlled loading changes as well as specimen prestrains

  3. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  4. IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP

    Directory of Open Access Journals (Sweden)

    Jianjun Luo

    2016-10-01

    Full Text Available In recent years, a big number of large diameter pre-stressed concrete cylinder pipe (PCCP lines have been applied to the Mid-route of the South-to-North Water Transfer Project. However, the leakage problem of PCCP causes annually heavy economic losses to our country. In such a context of situation, how to detect leaks rapidly and precisely after pipes appear cracks in water supply system has great significance. Based on the study and analysis of the characteristic structure of large diameter PCCP, a new leak detection system using fiber Bragg grating sensors, which can capture signals of water pressure change, is proposed. The feasibility, reliability and practicability of the system could be acceptable according to data achieved from in–situ tests. Moreover, the leak detection system can monitor in real-time of dynamic change of water pressure. The equations of the leakage quantity and water pressure have been presented in this paper, which can provide technical guidelines for large diameter PCCP lines maintenance.

  5. Soil-Structure Interaction for Non-Slender, Large-Diameter Offshore Monopiles

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal

    conducted. The initial part of p-y curves for non-slender piles has been investigated by means of numerical modelling. The general behaviour of eccentrically loaded non-slender piles has been investigated by physical modelling. These tests have been conducted in the pressure tank at Aalborg University....... The monopile foundation concept has been employed as the foundation for the majority of the currently installed offshore wind turbines. Therefore, this PhD thesis concerns the soil-pile interaction for non-slender, large-diameter offshore piles. A combination of numerical and physical modelling has been....... Hence, the application of an overburden pressure is possible. The timescale of the backfill process and the compaction of soil material backfilled around piles in storm conditions have been investigated by means of large-scale physical modelling....

  6. Influence of high intensity ultrasound with different probe diameter ...

    African Journals Online (AJOL)

    The main goal of this research is to analyze the influence of ultrasonic probe diameters (7 and 10 mm) of high-intensity ultrasound with constant frequency (30 kHz) on the degree of homogenization (variance) of cow milk. Influence of different probe diameters on the physical properties of cow milk was also tested. Changes ...

  7. Soil-Structure Interaction for Non-Slender, Large-Diameter Offshore Monopiles

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal

    Offshore wind power is a domestic, sustainable and largely untapped energy resource. Today, the modern offshore wind turbine offers competitive production prices compared to other sources of renewable energy. Therefore, it is a key technology in breaking the dependence on fossil fuels...... and in achieving the energy and climate goals of the future. For offshore wind turbines, the costs of foundation typically constitute 20-30% of the total costs. Hence, improved methods for the design of foundations for offshore wind turbines can increase the competitiveness of offshore wind energy significantly....... The monopile foundation concept has been employed as the foundation for the majority of the currently installed offshore wind turbines. Therefore, this PhD thesis concerns the soil-pile interaction for non-slender, large-diameter offshore piles. A combination of numerical and physical modelling has been...

  8. Improvement of estimation method of two-phase flow in a large diameter pipe. 2. Development of mechanistic interfacial drag force model

    International Nuclear Information System (INIS)

    Okawa, Tomio; Yoneda, Kimitoshi

    1998-01-01

    It is experimentally clarified that behavior of gas-liquid two-phase flow in large diameter pipe is different from one occurred in small diameter pipe. However, no special model for large diameter pipe is used in existing nuclear reactor safety analysis codes. In the present study, detailed investigation about the two-phase flow model used in the safety analysis was carried out to specify the physical phenomena which should be modeled more precisely. Based on the investigation, steam-water two-phase flow experiments using large diameter pipe was conducted to obtain new models. As a result, new evaluation methods for bubble size, heterogeneous distribution of void fraction, and wake formed behind bubble were developed. These new models were applied to the prediction of steam-water two-phase flow experiments using large diameter pipes to clarify their validity. It was consequently demonstrated that the accuracy of the numerical solution is remarkably improved not only for the experiment used for model development but also for the experiment where the pipe diameter, pressure, velocities, void fraction are different. (author)

  9. Results of geo-radio-monitoring for radioactive waste storage in large diameter boreholes in clayey ground

    International Nuclear Information System (INIS)

    Dmitriev, S.; Litinsky, Y.; Tkachenko, A.

    2010-01-01

    Document available in extended abstract form only. Full text of publication follows: The main purpose of the work carried out at the site of SUE MosSIA 'Radon' is to develop the system of geo-radio-monitoring for new type of storage facility (large diameter borehole) integrated into existing monitoring system of the whole site, check its effectiveness and improve the system, obtain initial results on safety aspects for using large diameter boreholes for RAW storage. Technology of large diameter boreholes (LDB) construction for low- and intermediate-level waste (LILW) isolation in moraine loams is being under development at SUE MosSIA 'Radon' site since the end of the last century. A project for construction of a demonstration unit for LILW storage in large diameter boreholes at the SUE MosSIA 'Radon' site in Sergiev Posad region has been developed taking into account specific site conditions. The main aim of the project is to develop the technology of LDB repository construction, operational procedures such as loading and retrieval, to develop and improve monitoring system for the new repository type, to get practical data on safety of radioactive wastes storage in new repositories, hermeticity of construction, and behavior of waste, waste packages, construction materials and near-field. In the case of LDB applications for LILW storage, the waste are removed from the scope of human activity into a stable geological medium. Waste are placed below the frost zone where damage of engineered barriers due to climatic factors is practically impossible. Two boreholes with 1.5 m internal diameter and 38 m depth have been drilled in 1997, equipped with engineering barriers including bentonite-concrete stone, licensed as storage facilities in 2003 and are in use now for solid and solidified RAW storage. Specific automated system of geo-radio-monitoring has been developed especially for the LDB-type repository, covering both the interior and the

  10. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-01-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast-iron test pipe segments. Efforts in the current quarter continued to focus on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported last quarter.) These tests identified several design issues which need to be implemented in both the small- and large-diameter

  11. Uniform, dense arrays of vertically aligned, large-diameter single-walled carbon nanotubes.

    Science.gov (United States)

    Han, Zhao Jun; Ostrikov, Kostya

    2012-04-04

    Precisely controlled reactive chemical vapor synthesis of highly uniform, dense arrays of vertically aligned single-walled carbon nanotubes (SWCNTs) using tailored trilayered Fe/Al(2)O(3)/SiO(2) catalyst is demonstrated. More than 90% population of thick nanotubes (>3 nm in diameter) can be produced by tailoring the thickness and microstructure of the secondary catalyst supporting SiO(2) layer, which is commonly overlooked. The proposed model based on the atomic force microanalysis suggests that this tailoring leads to uniform and dense arrays of relatively large Fe catalyst nanoparticles on which the thick SWCNTs nucleate, while small nanotubes and amorphous carbon are effectively etched away. Our results resolve a persistent issue of selective (while avoiding multiwalled nanotubes and other carbon nanostructures) synthesis of thick vertically aligned SWCNTs whose easily switchable thickness-dependent electronic properties enable advanced applications in nanoelectronic, energy, drug delivery, and membrane technologies.

  12. The spatial distribution of pollutants in pipe-scale of large-diameter pipelines in a drinking water distribution system.

    Science.gov (United States)

    Liu, Jingqing; Chen, Huanyu; Yao, Lingdan; Wei, Zongyuan; Lou, Liping; Shan, Yonggui; Endalkachew, Sahle-Demessie; Mallikarjuna, Nadagouda; Hu, Baolan; Zhou, Xiaoyan

    2016-11-05

    In large-diameter drinking water pipelines, spatial differences in hydraulic and physiochemical conditions may also result in spatial variations in pipe corrosion, biofilm growth and pollutant accumulation. In this article, the spatial distributions of various metals and organic contaminants in two 19-year-old grey cast iron pipes which had an internal diameter of 600mm (DN600), were investigated and analyzed by Atomic Absorption Spectrometry, Gas Chromatography-Mass Spectrometry, Energy Dispersive Spectrometer, X-ray Diffraction, etc. The spatial distribution of heavy metals varied significantly across the pipe section, and iron, manganese, lead, copper, and chromium were highest in concentration in the upper portion pipe-scales. However, the highest aluminum and zinc content was detected in the lower portion pipe-scales. Apart from some common types of hydrocarbons formed by microbial metabolites, there were also some microalgae metabolites and exogenous contaminants accumulated in pipe-scale, which also exhibited high diversity between different spatial locations. The spatial distributions of the physical and chemical properties of pipe-scale and contaminants were quite different in large-diameter pipes. The finding put forward higher requirements on the research method about drinking water distribution system chemical safety. And the scientific community need understand trend and dynamics of drinking water pipe systems better. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Physical Modelling of Large Diameter Piles in Coarse-Grained Soil

    DEFF Research Database (Denmark)

    Brødbæk, K. T.; Augustesen, Anders Hust; Møller, M.

    2011-01-01

    of increasing the effective stresses. The test setup is thoroughly described in the paper. Two non-slender aluminium pipe piles subjected to lateral loads have been tested in the laboratory. The piles are heavily instrumented with strain gauges in order to obtain p-y curves, displacement and bending moment......Monopiles are an often-used foundation concept for offshore wind turbine converters. These piles are highly subjected to lateral loads and overturning bending moments due to wind and wave forces. To ensure enough stiffness of the foundation and an acceptable pile-head deflection, monopiles...... with diameters of 4 to 6 m are typically employed. In current practice these piles are traditionally designed by means of the p-y curve method although the method is developed and verified for slender piles in sand with diameters up to approximately 2 m. One of the limitations of the p-y curves used in current...

  14. Flooding experiments with steam and water in a large diameter vertical tube

    International Nuclear Information System (INIS)

    Williams, S.N.; Solom, M.; Draznin, O.; Choutapalli, I.; Vierow, K.

    2009-01-01

    An experimental study on flooding in a large diameter tube is being conducted. In a countercurrent, two-phase flow system, flooding can be defined as the onset of flow reversal of the liquid component which results in cocurrent flow. Flooding can be perceived as a limit to two-phase countercurrent flow, meaning that pairs of liquid and gas flow rates exist that define the envelope for stable countercurrent flow for a given system. Flooding in the AP600 pressurizer surge line can affect the vessel refill rate following a small break LOCA. Analysis of hypothetical severe accidents with current simplified flooding models show that these models represent the largest uncertainty in steam generator tube creep rupture. During a hypothetical station blackout scenario without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg and flooding may occur in the surge line. Experiments have been conducted in a 3-inch (76.2 mm) diameter tube with subcooled water and superheated steam as the working fluids at atmospheric pressure. Water flows down the inside of the tube as an annulus while the steam flows upward in the middle. Water flow rates vary from 3.5 to 12 GPM (0.00022 to 0.00076 m 3 /s) and the water inlet temperature is about 70degC. The steam inlet temperature is about 110degC. It was found that a larger steam flow rate was needed to achieve flooding for a lower water flow rate and for a higher water flow rate. This unique data for flooding in steam-water systems in large diameter tubes will reduce uncertainty in flooding models currently utilized in reactor safety codes. (author)

  15. U-PHOS Project: Development of a Large Diameter Pulsating Heat Pipe Experiment on board REXUS 22

    International Nuclear Information System (INIS)

    Nannipieri, P; Anichini, M; Barsocchi, L; Becatti, G; Buoni, L; Celi, F; Catarsi, A; Di Giorgio, P; Fattibene, P; Ferrato, E; Guardati, P; Mancini, E; Meoni, G; Nesti, F; Piacquadio, S; Pratelli, E; Quadrelli, L; Viglione, A S; Zanaboni, F; Mameli, M

    2017-01-01

    U-PHOS Project aims at analysing and characterising the behaviour of a large diameter Pulsating Heat Pipe (PHP) on board REXUS 22 sounding rocket. A PHP is a passive thermal control device where the heat is efficiently transported by means of the self-sustained oscillatory fluid motion driven by the phase change phenomena. Since, in milli-gravity conditions, buoyancy forces become less intense, the PHP diameter may be increased still maintaining the slug/plug typical flow pattern. Consequently, the PHP heat power capability may be increased too. U-PHOS aims at proving that a large diameter PHP effectively works in milli-g conditions by characterizing its thermal response during a sounding rocket flight. The actual PHP tube is made of aluminum (3 mm inner diameter, filled with FC-72), heated at the evaporator by a compact electrical resistance, cooled at the condenser by a Phase Change Material (PCM) embedded in a metallic foam. The tube wall temperatures are recorded by means of Fibre Bragg Grating (FBG) sensors; the local fluid pressure is acquired by means of a pressure transducer. The present work intends to report the actual status of the project, focusing in particular on the experiment improvements with respect to the previous campaign. (paper)

  16. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-04-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of old cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed previously. Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in test cast-iron pipe segments. Efforts in the current quarter continued to be focused on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported previously.) Several design issues were identified which need to be implemented in both the small- and large-diameter repair

  17. Multi-dimensional two-phase flow measurements in a large-diameter pipe using wire-mesh sensor

    International Nuclear Information System (INIS)

    Kanai, Taizo; Furuya, Masahiro; Arai, Takahiro; Shirakawa, Kenetsu; Nishi, Yoshihisa; Ueda, Nobuyuki

    2011-01-01

    The authors developed a method of measurement to determine the multi-dimensionality of two phase flow. A wire-mesh sensor (WMS) can acquire a void fraction distribution at a high temporal and spatial resolution and also estimate the velocity of a vertical rising flow by investigating the signal time-delay of the upstream WMS relative to downstream. Previously, one-dimensional velocity was estimated by using the same point of each WMS at a temporal resolution of 1.0 - 5.0 s. The authors propose to extend this time series analysis to estimate the multi-dimensional velocity profile via cross-correlation analysis between a point of upstream WMS and multiple points downstream. Bubbles behave in various ways according to size, which is used to classify them into certain groups via wavelet analysis before cross-correlation analysis. This method was verified by air-water straight and swirl flows within a large-diameter vertical pipe. A high-speed camera is used to set the parameter of cross-correlation analysis. The results revealed that for the rising straight and swirl flows, large scale bubbles tend to move to the center, while the small bubble is pushed to the outside or sucked into the space where the large bubbles existed. Moreover, it is found that this method can estimate the rotational component of velocity of the swirl flow as well as measuring the multi-dimensional velocity vector at high temporal resolutions of 0.2 s. (author)

  18. Seamless vascularized large-diameter tubular collagen scaffolds reinforced with polymer knittings for esophageal regenerative medicine

    NARCIS (Netherlands)

    Hoogenkamp, H.R.; Koens, M.J.W.; Geutjes, P.J.; Ainoedhofer, H.; Wanten, G.J.A.; Tiemessen, D.M.; Hilborn, J.; Gupta, B.; Feitz, W.F.J.; Daamen, W.F.; Saxena, A.K.; Oosterwijk, E.; Kuppevelt, T.H. van

    2014-01-01

    A clinical demand exists for alternatives to repair the esophagus in case of congenital defects, cancer, or trauma. A seamless biocompatible off-the-shelf large-diameter tubular scaffold, which is accessible for vascularization, could set the stage for regenerative medicine of the esophagus. The use

  19. The spatial distribution of pollutants in pipe-scale of large-diameter pipelines in a drinking water distribution system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingqing [College of Engineering and Architecture, Zhejiang University, Hangzhou 310058 (China); Chen, Huanyu [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Binhai Industrial Technology Research Institute of Zhejiang University, Tianjin 300000 (China); Yao, Lingdan; Wei, Zongyuan [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Lou, Liping, E-mail: loulp@zju.edu.cn [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Shan, Yonggui; Endalkachew, Sahle-Demessie; Mallikarjuna, Nadagouda [Environmental Protection Agency, Office of Research and Development, NRMRL, Cincinnati, OH 45220 (United States); Hu, Baolan [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Zhou, Xiaoyan [Shaoxing Water Environmental Science Institute Co. Ltd, Zhejiang 312000 (China)

    2016-11-05

    Highlights: • First investigating the spatial distribution of pollutants in pipe-scale. • Spatial distribution of heavy metals indicated their sources were different. • Three main factors effete the distribution of pollutants. • Organic deposits mainly included microbial and microalgae metabolites. - Abstract: In large-diameter drinking water pipelines, spatial differences in hydraulic and physiochemical conditions may also result in spatial variations in pipe corrosion, biofilm growth and pollutant accumulation. In this article, the spatial distributions of various metals and organic contaminants in two 19-year-old grey cast iron pipes which had an internal diameter of 600 mm (DN600), were investigated and analyzed by Atomic Absorption Spectrometry, Gas Chromatography–Mass Spectrometry, Energy Dispersive Spectrometer, X-ray Diffraction, etc. The spatial distribution of heavy metals varied significantly across the pipe section, and iron, manganese, lead, copper, and chromium were highest in concentration in the upper portion pipe-scales. However, the highest aluminum and zinc content was detected in the lower portion pipe-scales. Apart from some common types of hydrocarbons formed by microbial metabolites, there were also some microalgae metabolites and exogenous contaminants accumulated in pipe-scale, which also exhibited high diversity between different spatial locations. The spatial distributions of the physical and chemical properties of pipe-scale and contaminants were quite different in large-diameter pipes. The finding put forward higher requirements on the research method about drinking water distribution system chemical safety. And the scientific community need understand trend and dynamics of drinking water pipe systems better.

  20. The spatial distribution of pollutants in pipe-scale of large-diameter pipelines in a drinking water distribution system

    International Nuclear Information System (INIS)

    Liu, Jingqing; Chen, Huanyu; Yao, Lingdan; Wei, Zongyuan; Lou, Liping; Shan, Yonggui; Endalkachew, Sahle-Demessie; Mallikarjuna, Nadagouda; Hu, Baolan; Zhou, Xiaoyan

    2016-01-01

    Highlights: • First investigating the spatial distribution of pollutants in pipe-scale. • Spatial distribution of heavy metals indicated their sources were different. • Three main factors effete the distribution of pollutants. • Organic deposits mainly included microbial and microalgae metabolites. - Abstract: In large-diameter drinking water pipelines, spatial differences in hydraulic and physiochemical conditions may also result in spatial variations in pipe corrosion, biofilm growth and pollutant accumulation. In this article, the spatial distributions of various metals and organic contaminants in two 19-year-old grey cast iron pipes which had an internal diameter of 600 mm (DN600), were investigated and analyzed by Atomic Absorption Spectrometry, Gas Chromatography–Mass Spectrometry, Energy Dispersive Spectrometer, X-ray Diffraction, etc. The spatial distribution of heavy metals varied significantly across the pipe section, and iron, manganese, lead, copper, and chromium were highest in concentration in the upper portion pipe-scales. However, the highest aluminum and zinc content was detected in the lower portion pipe-scales. Apart from some common types of hydrocarbons formed by microbial metabolites, there were also some microalgae metabolites and exogenous contaminants accumulated in pipe-scale, which also exhibited high diversity between different spatial locations. The spatial distributions of the physical and chemical properties of pipe-scale and contaminants were quite different in large-diameter pipes. The finding put forward higher requirements on the research method about drinking water distribution system chemical safety. And the scientific community need understand trend and dynamics of drinking water pipe systems better.

  1. Four-plate piezoelectric actuator driving a large-diameter special optical fiber for nonlinear optical microendoscopy.

    Science.gov (United States)

    Wang, Ying; Li, Zhi; Liang, Xiaobao; Fu, Ling

    2016-08-22

    In nonlinear optical microendoscope (NOME), a fiber with excellent optical characteristics and a miniature scanning mechanism at the distal end are two key components. Double-clad fibers (DCFs) and double-clad photonic crystal fibers (DCPCFs) have shown great optical characteristics but limited vibration amplitude due to large diameter. Besides reducing the damping of fiber cantilever, optimizing the structural of the actuator for lower energy dissipation also contributes to better driving capability. This paper presented an optimized actuator for driving a particular fiber cantilever in the view point of energy. Firstly, deformation energy of a bending fiber cantilever operating in resonant mode is investigated. Secondly, strain and stress analyses revealed that the four-plate actuator achieved lower energy dissipation. Then, finite-element simulations showed that the large-diameter fiber yielded an adequate vibration amplitude driven by a four-plate actuator, which was confirmed by experiments of our home-made four-plate actuator prototypes. Additionally, a NOME based on a DCPCF with a diameter of 350 μm driven by four-plate piezoelectric actuator has been developed. The NOME can excite and collect intrinsic second-harmonic and two-photon fluorescence signals with the excitation power of 10-30 mW and an adequate field of view of 200 μm, which suggest great potential applications in neuroscience and clinical diagnoses.

  2. Corrosion and deposit evaluation in large diameter pipes using radiography

    International Nuclear Information System (INIS)

    Boateng, A.

    2012-01-01

    The reliability and safety of industrial equipment in the factories and processing industries are substantially influenced by degradation processes such as corrosion, erosion, deposits and blocking of pipes. These might lead to low production, unpredictable and costly shutdowns due to repair and replacement and sometimes combined environmental pollution and risk of personnel injuries. Only periodic inspection for the integrity of pipes and equipment can reduce the risk in connection with other maintenance activities. The research explored two methods of radiographic inspection techniques, the double wall technique and the tangential radiographic technique using Ir-192 for evaluating deposits and corrosion attacks across the inner and outer walls of steel pipes with diameter greater than 150 mm with or without insulation. The application of both techniques was conducted depending on pipe diameter, wall thickness, radiation source (Ir-92) and film combination. The iridium source was positioned perpendicular with respect to the pipe axis projecting the double wall of the pipe on the plated radiographic film. With the tangential radiographic technique, the source was placed tangential to the pipe wall and because of its large diameter, the source was collimated to prevent backscatter and also to focus the beam at the target area of interest. All measurements were performed on special designed test pieces to simulate corrosion attack and deposits on industrial pipes. Pitting corrosion measurements based on Tangential Radiographic Technique were more sophisticated, and therefore magnification factor and correction were used to establish the estimated pit depth on the film. The insulating material used to conserve the thermodynamic properties of the transported media had relatively negligible attenuation coefficient compared to the concrete deposit. The two explored techniques were successful in evaluating corrosion attack and deposit on the walls of the pipe and the risk

  3. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of up-to-date facilities has been: Equipment for controlling centrifuge tests, data acquisition, preparation of test samples and equipment for and making of lateral load tests. The present research has been narrowed to investigate the static and cyclic behaviour of stiff piles with a diameter of 1-3 m...... in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... with a capacity of 3.6 MW and placed at water depths beyond 25 m. Different foundation solutions have over the years been applied for offshore turbines, but monopiles are currently the most applied foundation type and are typically with a pile diameter of 4-6 m and applied up to a water depth of 25 m...

  4. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  5. Demineralized water flow cancelling experiments with ice plug into high diameter horizontal tube (300 nominal diameter)

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Corbescu, B.; Puiu, D.; Panaitescu, V. N.

    2015-01-01

    The isolation with ice plug of a high diameter horizontal pipeline section is a specific technique for repairs activities/ replacements of components owning to thermo-hydraulic installations working with liquid agents. The application of such technique don.t assumes stopping of the entire system. The ice plugging inside of the pipeline assumes using of a special device and of an own specific technology for application. The paper contains a brief description of the experimental technological facilities used, followed by setting off the main moments in evolution of two experimental tests carried out on the test section with 300 mm nominal diameter for demineralized water and, finally, by a brief results analysis and some conclusions. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  6. Verification of the FBR fuel bundle-duct interaction analysis code BAMBOO by the out-of-pile bundle compression test with large diameter pins

    Science.gov (United States)

    Uwaba, Tomoyuki; Ito, Masahiro; Nemoto, Junichi; Ichikawa, Shoichi; Katsuyama, Kozo

    2014-09-01

    The BAMBOO computer code was verified by results for the out-of-pile bundle compression test with large diameter pin bundle deformation under the bundle-duct interaction (BDI) condition. The pin diameters of the examined test bundles were 8.5 mm and 10.4 mm, which are targeted as preliminary fuel pin diameters for the upgraded core of the prototype fast breeder reactor (FBR) and for demonstration and commercial FBRs studied in the FaCT project. In the bundle compression test, bundle cross-sectional views were obtained from X-ray computer tomography (CT) images and local parameters of bundle deformation such as pin-to-duct and pin-to-pin clearances were measured by CT image analyses. In the verification, calculation results of bundle deformation obtained by the BAMBOO code analyses were compared with the experimental results from the CT image analyses. The comparison showed that the BAMBOO code reasonably predicts deformation of large diameter pin bundles under the BDI condition by assuming that pin bowing and cladding oval distortion are the major deformation mechanisms, the same as in the case of small diameter pin bundles. In addition, the BAMBOO analysis results confirmed that cladding oval distortion effectively suppresses BDI in large diameter pin bundles as well as in small diameter pin bundles.

  7. Verification of the FBR fuel bundle–duct interaction analysis code BAMBOO by the out-of-pile bundle compression test with large diameter pins

    Energy Technology Data Exchange (ETDEWEB)

    Uwaba, Tomoyuki, E-mail: uwaba.tomoyuki@jaea.go.jp [Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Ibaraki 311-1393 (Japan); Ito, Masahiro; Nemoto, Junichi [Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Ibaraki 311-1393 (Japan); Ichikawa, Shoichi [Japan Atomic Energy Agency, 2-1, Shiraki, Tsuruga-shi, Fukui 919-1279 (Japan); Katsuyama, Kozo [Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Ibaraki 311-1393 (Japan)

    2014-09-15

    The BAMBOO computer code was verified by results for the out-of-pile bundle compression test with large diameter pin bundle deformation under the bundle–duct interaction (BDI) condition. The pin diameters of the examined test bundles were 8.5 mm and 10.4 mm, which are targeted as preliminary fuel pin diameters for the upgraded core of the prototype fast breeder reactor (FBR) and for demonstration and commercial FBRs studied in the FaCT project. In the bundle compression test, bundle cross-sectional views were obtained from X-ray computer tomography (CT) images and local parameters of bundle deformation such as pin-to-duct and pin-to-pin clearances were measured by CT image analyses. In the verification, calculation results of bundle deformation obtained by the BAMBOO code analyses were compared with the experimental results from the CT image analyses. The comparison showed that the BAMBOO code reasonably predicts deformation of large diameter pin bundles under the BDI condition by assuming that pin bowing and cladding oval distortion are the major deformation mechanisms, the same as in the case of small diameter pin bundles. In addition, the BAMBOO analysis results confirmed that cladding oval distortion effectively suppresses BDI in large diameter pin bundles as well as in small diameter pin bundles.

  8. A Snapshot of Present Research at AAU and DTU on Large-Diameter Piles in Coarse-Grained Materials

    DEFF Research Database (Denmark)

    Leth, C. T.; Sørensen, Søren Peder Hyldal; Klinkvort, Rasmus Tofte

    2012-01-01

    are developed for piles with diameters up to approximately 2.0 m and are based on a very limited number of tests. Hence, the method has not been validated for piles with diameters of 4 to 6 m. During the last six years extensive studies on non-slender large-diameter piles in coarse-grained material have been...... conducted at Aalborg University (AAU) and at the Technical University of Denmark (DTU). The piles have been investigated by means of physical and numerical modelling. The former consists of both centrifuge tests and tests in a so-called pressure tank (1G tests but with an applied overburden pressure......). The goal of the work has been to investigate the general behaviour of monopiles for nowadays offshore wind turbines and to revise the p-y curves for piles in sand in order to account for diameter on the response of monopiles subjected to both static and cyclic loads. The paper summarizes and compares...

  9. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-11-01

    - and large-diameter cast iron repair robots to assure their commercial success. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module in the last quarter 5. In this quarter, work has been concentrated on increasing the nitrogen bladder reservoir volume to allow at least two complete patch inflation/patch setting cycles in the event the sleeve does not set all ratchets in the same row on the first attempt. This problem was observed on a few of the repair sleeves that were recently installed during field tests with the small-diameter robotic system. For Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) it was observed that it will be necessary to add a stiff brush to push debris away from the immediate vicinity of the bell and spigot joints in mains having low gas velocities. Otherwise, material removed by the cleaning flails (which were found to be very effective in cleaning bell and spigot joints) simply falls to the low side of the pipe and accumulates in a pile. This accumulation can prevent the sleeve from achieving a leak free repair. Similarly, it is also necessary to design a small magnet to capture existing service tap coupons and allow their removal from the inside of the pipe. These coupons were found to cause difficulty in launching and retrieving the small pipe repair robot; one coupon lodged beneath the end of the guide shoe. These new features require redesign of the pipe wall cleaning train and modification to the patch setting train. Task 6 (Design & Build Surface Control and Monitoring System) was previously completed with the control and computer display functions being operated through LabView. However, this must now be re-visited to add control routines for the coupon catcher to be added. This will most likely include a lift-off/place-on magnet translation function. Task 7 (Design

  10. Improvement of Estimation method for two-phase flow in a large-diameter pipe. Pt. 4. Effect of the inlet boundary condition of the upward flow section on flow characteristics

    International Nuclear Information System (INIS)

    Yoneda, Kimitoshi; Okawa, Tomio; Zhou, Shirong

    1999-01-01

    In nuclear power plants, many large-diameter pipes are subject to gas-liquid two-phase flow. For rational design and performance estimation, the flow in the pipes should be predicted accurately. With the correlation used at present, however, the flow analysis can not reach desirable precision. This is partly due to the lack of understanding of the two-phase flow characteristics in large-diameter pipes. Therefore, steam-water two-phase flow in a vertical pipe (155 mm i.d.) was investigated empirically. Lateral distribution data of phase volume fraction, gas velocity and bubble diameter were obtained. The effects of the inlet boundary condition were also observed. The drift velocity in the developing region was considerably affected by the inlet boundary condition. By deriving the correlation of mean bubble diameter as a function of void fraction and pressure, the empirical data was predicted with high accuracy compared with the existing correlation used in best-estimate codes of nuclear reactor safety analysis. (author)

  11. The design of lifting attachments for the erection of large diameter and heavy wall pressure vessels

    International Nuclear Information System (INIS)

    Antalffy, Leslie P.; Miller, George A.; Kirkpatrick, Kenneth D.; Rajguru, Anil; Zhu, Yong

    2016-01-01

    Lifting attachments for the erection of large diameter and heavy wall pressure vessels require special consideration to ensure that their attachment to their vessel shells or heads do not overstress the vessel during the erection process when lifting these from grade onto their respective foundations. Today, in refinery and petrochemical services, large diameter vessels with diameters ranging up to 15 m and reactors with lifting weights in the range of 700–1400 tons are not uncommon. In today's fabrication market, these vessels may be purchased and fabricated in shops dispersed globally and will require unique equipment for their safe handling, transportation and subsequent erection. The challenge is to design the lifting attachments in such a manner that the attachments provide a safe, cost effective and effective solution based upon the limitations of the job site lift equipment available for erection. Such equipment for the transportation and subsequent lifting of large diameter and heavy wall pressure equipment is usually scarce and quite expensive. Planning ahead, well in advance of the lift date is almost a mandatory requirement. Usually, the specific parameters of the vessel to be lifted and the lifting equipment available at the site will dictate the type of lifting attachments to be designed for the vessel. Once the type of vessel attachment has been chosen, careful consideration must be given to the design of attachments to the pressure vessel in consideration to ensure that the vessel and lifting components are not overstressed during the lifting process. The paper also discusses different types of lifting attachments that may be attached to each end of the vessel either by bolting or welding and discusses the pros and cons of each. The paper also provides an example of a finite element analysis (FEA) of a top nozzle, a FEA of a pair of lifting trunnions and a FEA of welded on lifting lugs for buried pipe. The purpose of the paper is to outline the

  12. Potential for large-diameter NTD silicon production in the Advanced Test Reactor

    International Nuclear Information System (INIS)

    Herring, J.S.; Korenke, R.E.

    1984-01-01

    The Advanced Test Reactor (ATR) is a 250-MW(t) flux-trap reactor located at the Idaho National Engineering Laboratory (INEL). Within the reflector are four 124-mm-diameter I-holes, which are available for silicon irradiation. Two large irradiation volumes of 0.5 m x 0.4 m x 1.2 m and 0.5 m x 0.2 m x 1.2 m are also available for transmutation doping. Thermal fluxes in these locations range from 0.56 to 23.0 x 10 12 nt/cm 3 -s. Use of the ATR for providing neutron transmutation doping (NTD) services in sizes not available elsewhere in the United States may be feasible

  13. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari, Gerard T. Pittard

    2004-01-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to the design, fabrication and testing of a entry fitting in a 4-inch prototype and is now being used to complete drawings for use in 12-inch diameter pipe. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  14. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M Kothari; Gerard T. Pittard

    2004-07-01

    ) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being manufactured. The 12-inch ball valve for allowing no-blow access was also procured. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

  15. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-04-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being placed into manufacture. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  16. Production of small diameter high-temperature-strength refractory metal wires

    Science.gov (United States)

    Petrasek, D. W.; Signorelli, R. A.; King, G. W.

    1973-01-01

    Special thermomechanical techniques (schedules) have been developed to produce small diameter wire from three refractory metal alloys: colombian base alloy, tantalum base alloy, and tungsten base alloy. High strengths of these wires indicate their potential for contributing increased strength to metallic composites.

  17. Diameter Tuning of Single-Walled Carbon Nanotubes by Diffusion Plasma CVD

    Directory of Open Access Journals (Sweden)

    Toshiaki Kato

    2011-01-01

    Full Text Available We have realized a diameter tuning of single-walled carbon nanotubes (SWNTs by adjusting process gas pressures with plasma chemical vapor deposition (CVD. Detailed photoluminescence measurements reveal that the diameter distribution of SWNTs clearly shifts to a large-diameter region with an increase in the pressure during plasma CVD, which is also confirmed by Raman scattering spectroscopy. Based on the systematical investigation, it is found that the main diameter of SWNTs is determined by the pressure during the heating in an atmosphere of hydrogen and the diameter distribution is narrowed by adjusting the pressure during the plasma generation. Our results could contribute to an application of SWNTs to high-performance thin-film transistors, which requires the diameter-controlled semiconductor-rich SWNTs.

  18. BDI behavior evaluation of an upgraded Monju core and a demonstration core. (1) Plans for the out of pile bundle compressive tests for large diameter pins

    International Nuclear Information System (INIS)

    Ichikawa, Shoichi; Haga, Hiroyuki; Katsuyama, Kozo; Uwaba, Tomoyuki; Maeda, Koji; Nishinoiri, Kenji

    2012-07-01

    The life of FBR (Fast Breeder Reactor) fuel assembly is restricted by BDI (Bundle-Duct Interaction). Therefore, it is very important to carry out the out pile bundle compressive tests which can imitate BDI, in order to evaluate BDI behavior. The target of the conventional BDI behavior was small diameter pins (φ6.5mm) for fuel pellets which were used with the assembly of Monju (the Monju prototype fast breeder reactor) etc. Furthermore by an upgraded Monju core and a demonstration core, adoption of large diameter pins for the holler annular pellets is planned. Therefore, it was necessary to carry out BDI evaluation of a large diameter pin. Then, the plans for out of pile bundle compressive test for large diameter pins were are reported. (author)

  19. Recent development in crystal growth of large-diameter Y-QMG (reg sign) bulk superconductors; Y kei ogata QMG (reg sign) baruku koonchodendotai no kaihatsu jokyo

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, T.; Morita, M. [Nippon Steel Corporation, Tokyo (Japan); Masahashi, N. [Tohoku University, Miyagi (Japan). Institute for Materials Research

    1999-11-25

    The current status of large-diameter Y-Ba-Cu-O OMG(reg sign) bulk superconductors is described. 75 mm-diameter QMG(reg sign) samples with fairly concentric trapped-magnetic-flux-density distributions have been successfully grown. In addition, a record-high value of the magnetic levitation force, 171 kgf, measured at 77 K using a 90 mm-diameter Nd-Fe-B magnet has been obtained for a 100 mm-diameter sample. The crystal orientation of subgrains in the sample was determined using Electron Back-Scattering Diffraction as well as using a conventional optical apparatus including a He-Ne-laser. For the sample grown under normal process conditions, the maximum value of the [001]-axis misorientation angles at the subgrain-boundaries we obtained in the c-substructure region is 2.9 degree. However, in the a/b-substructure regions, the misorientation angles are larger, and the maximum value obtained is 6.6 degree, exceeding the critical angle at which a significant reduction of the critical current density occurs in Y123 thin films due to the weak-link problem. (author)

  20. 78 FR 41366 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 4 1/2

    Science.gov (United States)

    2013-07-10

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-588-850] Certain Large Diameter... Operations, Office 1, Import Administration, International Trade Administration, U.S. Department of Commerce... Results of Antidumping Duty Administrative Review; 2011-2012 AGENCY: Import Administration, International...

  1. High-performance radio frequency transistors based on diameter-separated semiconducting carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yu; Che, Yuchi; Zhou, Chongwu, E-mail: chongwuz@usc.edu [Department of Electrical Engineering, University of Southern California, Los Angeles, California 90089 (United States); Seo, Jung-Woo T.; Hersam, Mark C. [Department of Materials Science and Engineering and Department of Chemistry, Northwestern University, Evanston, Illinois 60208 (United States); Gui, Hui [Department of Chemical Engineering and Materials Science, University of Southern California, Los Angeles, California 90089 (United States)

    2016-06-06

    In this paper, we report the high-performance radio-frequency transistors based on the single-walled semiconducting carbon nanotubes with a refined average diameter of ∼1.6 nm. These diameter-separated carbon nanotube transistors show excellent transconductance of 55 μS/μm and desirable drain current saturation with an output resistance of ∼100 KΩ μm. An exceptional radio-frequency performance is also achieved with current gain and power gain cut-off frequencies of 23 GHz and 20 GHz (extrinsic) and 65 GHz and 35 GHz (intrinsic), respectively. These radio-frequency metrics are among the highest reported for the carbon nanotube thin-film transistors. This study provides demonstration of radio frequency transistors based on carbon nanotubes with tailored diameter distributions, which will guide the future application of carbon nanotubes in radio-frequency electronics.

  2. On the performance of small diameter gas cyclones

    International Nuclear Information System (INIS)

    Halasz, Marcos Roberto Teixeira

    2002-02-01

    Small diameter cyclones represent a potential alternative for the removal of small diameter particles from gaseous mixtures as well as the environmental control of their emission. In order to establish feasible configurations of a small diameter cyclone applied in the separation of solid particles dispersed in a gas and considering a large quantify of experimental data in literature, neural networks were used to estimate the equipment grade efficiency and pressure drop. In order to evaluate a performance of many small diameters configurations and analysis was carried of parametrical sensibility which determines the most important variables on separation efficiency determination. A set of experimental runs was carried out in a lab-scale mini-cyclone in order to obtain the separation efficiency and pressure drop for different configurations, and evaluate the feasibility of coupling a post-cyclone device to improve the equipment overall performance. The cyclones used presented diameters of 0.03 and 0.05 m and the remaining dimensions varied proportionally about those found in Stairmand high-efficiency cyclones. Experimental separation efficiencies up to 99% were obtained in this work. These results confirm the feasibility of the experimental set-up configuration proposed. (author)

  3. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  4. Two-group modeling of interfacial area transport in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65409 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2015-11-15

    Highlights: • Implemented updated constitutive models and benchmarking method for IATE in large pipes. • New model and method with new data improved the overall IATE prediction for large pipes. • Not all conditions well predicted shows that further development is still required. - Abstract: A comparison of the existing two-group interfacial area transport equation source and sink terms for large diameter channels with recently collected interfacial area concentration measurements (Schlegel et al., 2012, 2014. Int. J. Heat Fluid Flow 47, 42) has indicated that the model does not perform well in predicting interfacial area transport outside of the range of flow conditions used in the original benchmarking effort. In order to reduce the error in the prediction of interfacial area concentration by the interfacial area transport equation, several constitutive relations have been updated including the turbulence model and relative velocity correlation. The transport equation utilizing these updated models has been modified by updating the inter-group transfer and Group 2 coalescence and disintegration kernels using an expanded range of experimental conditions extending to pipe sizes of 0.304 m [12 in.], gas velocities of up to nearly 11 m/s [36.1 ft/s] and liquid velocities of up to 2 m/s [6.56 ft/s], as well as conditions with both bubbly flow and cap-bubbly flow injection (Schlegel et al., 2012, 2014). The modifications to the transport equation have resulted in a decrease in the RMS error for void fraction and interfacial area concentration from 17.32% to 12.3% and 21.26% to 19.6%. The combined RMS error, for both void fraction and interfacial area concentration, is below 15% for most of the experiments used in the comparison, a distinct improvement over the previous version of the model.

  5. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  6. Influence of Thread Root Radius on Maximum Local Stresses at Large Diameter Bolts under Axial Loading

    Directory of Open Access Journals (Sweden)

    Cojocaru Vasile

    2014-06-01

    Full Text Available In the thread root area of the threaded bolts submitted to axial loading occur local stresses, higher that nominal stresses calculated for the bolts. These local stresses can generate failure and can reduce the fatigue life of the parts. The paper is focused on the study of the influence of the thread root radius on the maximum local stresses. A large diameter trapezoidal bolt was subjected to a static analysis (axial loading using finite element simulation.

  7. Design and Fabrication of Large Diameter Gradient-Index Lenses for Dual-Band Visible to Short-Wave Infrared Imaging Applications

    Science.gov (United States)

    Visconti, Anthony Joseph

    The fabrication of gradient-index (GRIN) optical elements is quite challenging, which has traditionally restricted their use in many imaging systems; consequently, commercial-level GRIN components usually exist in one particular market or niche application space. One such fabrication technique, ion exchange, is a well-known process used in the chemical strengthening of glass, the fabrication of waveguide devices, and the production of small diameter GRIN optical relay systems. However, the manufacturing of large diameter ion-exchanged GRIN elements has historically been limited by long diffusion times. For example, the diffusion time for a 20 mm diameter radial GRIN lens in commercially available ion exchange glass for small diameter relays, is on the order of a year. The diffusion time can be dramatically reduced by addressing three key ion exchange process parameters; the composition of the glass, the diffusion temperature, and the composition of the salt bath. Experimental work throughout this thesis aims to (1) scale up the ion exchange diffusion process to 20 mm diameters for a fast-diffusing titania silicate glass family in both (2) sodium ion for lithium ion (Na+ for Li+) and lithium ion for sodium ion (Li+ for Na+) exchange directions, while (3) utilizing manufacturing friendly salt bath compositions. In addition, optical design studies have demonstrated that an important benefit of gradient-index elements in imaging systems is the added degree of freedom introduced with a gradient's optical power. However, these studies have not investigated the potential usefulness of GRIN materials in dual-band visible to short-wave infrared (vis-SWIR) imaging systems. The unique chromatic properties of the titania silicate ion exchange glass become a significant degree of freedom in the design process for these color-limited, broadband imaging applications. A single GRIN element can replace a cemented doublet or even a cemented triplet, without loss in overall system

  8. Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines

    Directory of Open Access Journals (Sweden)

    Tamar Andelman

    2007-01-01

    Full Text Available A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm nanorods were synthesized from trihexylamine, and large diameter (50–80 nm nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green emission of the photoluminescence (PL spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.

  9. PERFORMANCE EVALUATION OF AN INNOVATIVE FIBER REINFORCED GEOPOLYMER SPRAY-APPLIED MORTAR FOR LARGE DIAMETER WASTEWATER MAIN REHABILITATION IN HOUSTON, TX

    Science.gov (United States)

    This report describes the performance evaluation of a fiber reinforced geopolymer spray-applied mortar, which has potential as a structural alternative to traditional open cut techniques used in large-diameter sewer pipes. Geopolymer is a sustainable green material that incorpor...

  10. Impulse electron gun with plasma cathode for realization of large diameter tube-shaped beams

    International Nuclear Information System (INIS)

    Antipov, V.S.; Karpukhin, V.I.; Kornilov, E.A.

    1999-01-01

    There are presented the results of investigations of a plasma electron source based on the gas discharge in a coaxial system of electrodes with longitudinal magnetic field. The examination is fulfilled from the viewpoint of applying the source as a plasma cathode for hybrid plasma-waveguide slow-wave structures on the basis of a disk-loaded coaxial. The source is optimized in order to get a powerful (up to 100 kW) nonrelativistic electron beam with the annular cross-section of a large diameter in the regime of relatively long current pulses (up to 0.2 ms) under the gas pressure ∼ 5 centre dot 10 -4 mm Hg in the area of the discharge burning

  11. Reproducible, large-scale production of thallium-based high-temperature superconductors

    International Nuclear Information System (INIS)

    Gay, R.L.; Stelman, D.; Newcomb, J.C.; Grantham, L.F.; Schnittgrund, G.D.

    1990-01-01

    This paper reports on the development of a large scale spray-calcination technique generic to the preparation of ceramic high-temperature superconductor (HTSC) powders. Among the advantages of the technique is that of producing uniformly mixed metal oxides on a fine scale. Production of both yttrium and thallium-based HTSCs has been demonstrated using this technique. In the spray calciner, solutions of the desired composition are atomized as a fine mist into a hot gas. Evaporation and calcination are instantaneous, yielding an extremely fine, uniform oxide powder. The calciner is 76 cm in diameter and can produce metal oxide powder at relatively large rates (approximately 100 g/h) without contamination

  12. Highly segmented large-area hybrid photodiodes with bialkali photocathodes and enclosed VLSI readout electronics

    CERN Document Server

    Braem, André; Filthaut, Frank; Go, A; Joram, C; Weilhammer, Peter; Wicht, P; Dulinski, W; Séguinot, Jacques; Wenzel, H; Ypsilantis, Thomas

    2000-01-01

    We report on the principles, design, fabrication, and operation of a highly segmented, large-area hybrid photodiode, which is being developed in the framework of the LHCb RICH project. The device consists of a cylindrical, 127 mm diameter vacuum envelope capped with a spherical borosilicate UV-glass entrance window, with an active-to-total-area fraction of 81A fountain-focusing electron optics is used to demagnify the image onto a 50 mm diameter silicon sensor, containing 2048 pads of size 1*1 mm/sup 2/. (10 refs).

  13. FACES WITH LARGE DIAMETER ON THE SYMMETRICAL TRAVELING SALESMAN POLYTOPE

    NARCIS (Netherlands)

    SIERKSMA, G; TIJSSEN, GA

    This paper deals with the symmetric traveling salesman polytope and contains three main theorems. The first one gives a new characterization of (non)adjacency. Based on this characterization a new upper bound for the diameter of the symmetric traveling salesman polytope (conjectured to be 2 by M.

  14. Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  15. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

    Science.gov (United States)

    Georgiou, Cs; Evangelou, Kg; Theodorou, Eg; Provatidis, Cg; Megas, Pd

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed.

  16. High-Q submicron-diameter quantum-dot microcavity pillars for cavity QED experiments

    DEFF Research Database (Denmark)

    Gregersen, Niels; Lermer, Matthias; Dunzer, Florian

    As/AlAs micropillar design where Bloch-wave engineering is employed to significally enhance the cavity mode confinement in the submicron diameter regime. We demonstrate a record-high vacuum Rabi splitting of 85 µeV of the strong coupling for pillars incorporating quantum dots with modest oscillator strength f ≈ 10....... It is well-known that light-matter interaction depends on the photonic environment, and thus proper engineering of the optical mode in microcavity systems is central to obtaining the desired functionality. In the strong coupling regime, the visibility of the Rabi splitting is described by the light...... coupling in micropillars relied on quantum dots with high oscillator strengths f > 50, our advanced design allows for the observation of strong coupling for submicron diameter quantum dot-pillars with standard f ≈ 10 oscillator strength. A quality factor of 13600 and a vacuum Rabi splitting of 85 µe...

  17. Processing large-diameter poly(L-lactic acid) microfiber mesh/mesenchymal stromal cell constructs via resin embedding: an efficient histologic method

    International Nuclear Information System (INIS)

    D’Alessandro, Delfo; Danti, Serena; Pertici, Gianni; Moscato, Stefania; Metelli, Maria Rita; Petrini, Mario; Danti, Sabrina; Berrettini, Stefano; Nesti, Claudia

    2014-01-01

    In this study, we performed a complete histologic analysis of constructs based on large diameter ( > 100 μm) poly-L-lactic acid (PLLA) microfibers obtained via dry-wet spinning and rat Mesenchymal Stromal Cells (rMSCs) differentiated towards the osteogenic lineage, using acrylic resin embedding. In many synthetic polymer-based microfiber meshes, ex post processability of fiber/cell constructs for histologic analysis may face deterring difficulties, leading to an incomplete investigation of the potential of these scaffolds. Indeed, while polymeric nanofiber (fiber diameter = tens of nanometers)/cell constructs can usually be embedded in common histologic media and easily sectioned, preserving the material structure and the antigenic reactivity, histologic analysis of large polymeric microfiber/cell constructs in the literature is really scant. This affects microfiber scaffolds based on FDA-approved and widely used polymers such as PLLA and its copolymers. Indeed, for such constructs, especially those with fiber diameter and fiber interspace much larger than cell size, standard histologic processing is usually inefficient due to inhomogeneous hardness and lack of cohesion between the synthetic and the biological phases under sectioning. In this study, the microfiber/MSC constructs were embedded in acrylic resin and the staining/reaction procedures were calibrated to demonstrate the possibility of successfully employing histologic methods in tissue engineering studies even in such difficult cases. We histologically investigated the main osteogenic markers and extracellular matrix molecules, such as alkaline phosphatase, osteopontin, osteocalcin, TGF-β1, Runx2, Collagen type I and the presence of amorphous, fibrillar and mineralized matrix. Biochemical tests were employed to confirm our findings. This protocol permitted efficient sectioning of the treated constructs and good penetration of the histologic reagents, thus allowing distribution and expression of

  18. Q0000-398 is a high-redshift quasar with a large angular size

    International Nuclear Information System (INIS)

    Gearhart, M.R.; Pacht, E.

    1977-01-01

    A study is described, using the three-element interferrometer at the National Radio Astronomy Observatory, West Virginia, to investigate whether any quasars exist that might be radio sources. It was found that Q0000-398 appeared to be a quasar of high red shift and large angular size. The interferrometer was operated with a 300-1200-1500 m baseline configuration at 2695 MHz. The radio map for Q0000-398 is shown, and has two weak components separated by 134 +- 40 arc s. If these components are associated with the optical object this quasar has the largest known angular size for its red shift value. The results reported for Q0000-398 and other quasars having considerable angular extent demonstrate the importance of considering radio selection effects in the angular diameter-red shift relationship, and since any radio selection effects are removed when quasars are selected optically, more extensive mapping programs should be undertaken, looking particularly for large scale structure around optically selected high-z quasars. (U.K.)

  19. Void fraction development in gas-liquid flow after a U-bend in a vertically upwards serpentine-configuration large-diameter pipe

    Science.gov (United States)

    Almabrok, Almabrok A.; Aliyu, Aliyu M.; Baba, Yahaya D.; Lao, Liyun; Yeung, Hoi

    2018-01-01

    We investigate the effect of a return U-bend on flow behaviour in the vertical upward section of a large-diameter pipe. A wire mesh sensor was employed to study the void fraction distributions at axial distances of 5, 28 and 47 pipe diameters after the upstream bottom bend. The study found that, the bottom bend has considerable impacts on up-flow behaviour. In all conditions, centrifugal action causes appreciable misdistribution in the adjacent straight section. Plots from WMS measurements show that flow asymmetry significantly reduces along the axis at L/D = 47. Regime maps generated from three axial locations showed that, in addition to bubbly, intermittent and annular flows, oscillatory flow occurred particularly when gas and liquid flow rates were relatively low. At this position, mean void fractions were in agreement with those from other large-pipe studies, and comparisons were made with existing void fraction correlations. Among the correlations surveyed, drift flux-type correlations were found to give the best predictive results.

  20. Facilitative-competitive interactions in an old-growth forest: the importance of large-diameter trees as benefactors and stimulators for forest community assembly.

    Science.gov (United States)

    Fichtner, Andreas; Forrester, David I; Härdtle, Werner; Sturm, Knut; von Oheimb, Goddert

    2015-01-01

    The role of competition in tree communities is increasingly well understood, while little is known about the patterns and mechanisms of the interplay between above- and belowground competition in tree communities. This knowledge, however, is crucial for a better understanding of community dynamics and developing adaptive near-natural management strategies. We assessed neighbourhood interactions in an unmanaged old-growth European beech (Fagus sylvatica) forest by quantifying variation in the intensity of above- (shading) and belowground competition (crowding) among dominant and co-dominant canopy beech trees during tree maturation. Shading had on average a much larger impact on radial growth than crowding and the sensitivity to changes in competitive conditions was lowest for crowding effects. We found that each mode of competition reduced the effect of the other. Increasing crowding reduced the negative effect of shading, and at high levels of shading, crowding actually had a facilitative effect and increased growth. Our study demonstrates that complementarity in above- and belowground processes enable F. sylvatica to alter resource acquisition strategies, thus optimising tree radial growth. As a result, competition seemed to become less important in stands with a high growing stock and tree communities with a long continuity of anthropogenic undisturbed population dynamics. We suggest that growth rates do not exclusively depend on the density of potential competitors at the intraspecific level, but on the conspecific aggregation of large-diameter trees and their functional role for regulating biotic filtering processes. This finding highlights the potential importance of the rarely examined relationship between the spatial aggregation pattern of large-diameter trees and the outcome of neighbourhood interactions, which may be central to community dynamics and the related forest ecosystem services.

  1. Facilitative-Competitive Interactions in an Old-Growth Forest: The Importance of Large-Diameter Trees as Benefactors and Stimulators for Forest Community Assembly

    Science.gov (United States)

    Fichtner, Andreas; Forrester, David I.; Härdtle, Werner; Sturm, Knut; von Oheimb, Goddert

    2015-01-01

    The role of competition in tree communities is increasingly well understood, while little is known about the patterns and mechanisms of the interplay between above- and belowground competition in tree communities. This knowledge, however, is crucial for a better understanding of community dynamics and developing adaptive near-natural management strategies. We assessed neighbourhood interactions in an unmanaged old-growth European beech (Fagus sylvatica) forest by quantifying variation in the intensity of above- (shading) and belowground competition (crowding) among dominant and co-dominant canopy beech trees during tree maturation. Shading had on average a much larger impact on radial growth than crowding and the sensitivity to changes in competitive conditions was lowest for crowding effects. We found that each mode of competition reduced the effect of the other. Increasing crowding reduced the negative effect of shading, and at high levels of shading, crowding actually had a facilitative effect and increased growth. Our study demonstrates that complementarity in above- and belowground processes enable F. sylvatica to alter resource acquisition strategies, thus optimising tree radial growth. As a result, competition seemed to become less important in stands with a high growing stock and tree communities with a long continuity of anthropogenic undisturbed population dynamics. We suggest that growth rates do not exclusively depend on the density of potential competitors at the intraspecific level, but on the conspecific aggregation of large-diameter trees and their functional role for regulating biotic filtering processes. This finding highlights the potential importance of the rarely examined relationship between the spatial aggregation pattern of large-diameter trees and the outcome of neighbourhood interactions, which may be central to community dynamics and the related forest ecosystem services. PMID:25803035

  2. Profile Control by Biased Electrodes in Large Diameter RF Produced Pl asma

    Science.gov (United States)

    Shinohara, Shunjiro; Matsuoka, Norikazu; Yoshinaka, Toshiro

    1998-10-01

    Control of the plasma profile has been carried out, using the voltage biasing method in the large diameter (45 cm) RF (radio frequency) produced plasma in the presence of the uniform magnetic field (less than 1200 G). Under the low filling pressure condition of 0.16 mTorr, changing the biasing voltages to the three individual end plates with concentric circular ring shapes, the radial electron density (about 10^10 cm-3) profile could be changed from the hollow to the peaked one. On the contrary, the nearly flat electron temperature (several eV) profile did not change appreciably. The azimuthal rotation velocity measured by the Mach probe, i.e. directional probe, showed the different radial profiles (but nearly uniform along the axis) depending on the biasing voltage. This velocity became slower with the low magnetic field (less than 200 G) or in the higher pressure regime up to 20 mTorr with the higher electron density. The experimental results by other biasing methods will also be presented.

  3. Large-Diameter Burrows of the Triassic Ischigualasto Basin, NW Argentina: Paleoecological and Paleoenvironmental Implications

    Science.gov (United States)

    Colombi, Carina E.; Fernández, Eliana; Currie, Brian S.; Alcober, Oscar A.; Martínez, Ricardo; Correa, Gustavo

    2012-01-01

    Large-diameter ichnofossils comprising three morphotypes have been identified in the Upper Triassic Ischigualasto and Los Colorados formations of northwestern Argentina. These burrows add to the global record of the early appearance of fossorial behavior during early Mesozoic time. Morphotypes 1 and 2 are characterized by a network of tunnels and shafts that can be assigned to tetrapod burrows given similarities with previously described forms. However, differences in diameter, overall morphology, and stratigraphic occurrence allow their independent classification. Morphotype 3 forms a complex network of straight branches that intersect at oblique angles. Their calcareous composition and surface morphology indicate these structures have a composite biogenic origin likely developed due to combined plant/animal interactions. The association of Morphotypes 1 and 2 with fluvial overbank lithologies deposited under an extremely seasonal arid climate confirms interpretations that the early appearance of burrowing behavior was employed by vertebrates in response to both temperature and moisture-stress associated with seasonally or perpetually dry Pangean paleoclimates. Comparisons of burrow morphology and biomechanical attributes of the abundant paleovertebrate fauna preserved in both formations permit interpretations regarding the possible burrow architects for Morphotypes 1 and 2. In the case of the Morphotype 1, the burrow constructor could be one of the small carnivorous cynodonts, Ecteninion or Probelesodon. Assigning an architect for Morphotype 2 is more problematic due to mismatches between the observed burrow morphology and the size of the known Los Colorados vertebrates. PMID:23227195

  4. An experimental investigation on the pressure characteristics of high speed self-resonating pulsed waterjets influenced by feeding pipe diameter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dong; Kang, Dong; Ding, Xiao Long; Wang, Xiao Huan; Fang, Zhen Long [School of Power and Mechanical Engineering, Wuhan University, Hubei Province (China)

    2016-11-15

    The destructive power of a continuous waterjet issuing from a nozzle can be greatly enhanced by generating self-resonance in the nozzle assembly to produce a Self-resonating pulsed waterjet (SRPW). To further improve the performance of SRPW, effects of feeding pipe diameter on the pressure characteristics were experimentally investigated by measuring and analyzing the axial pressure oscillation peaks and amplitudes. Four organ-pipe nozzles of different chamber lengths and three feeding pipes of different diameters were employed. Results show that feeding pipe diameter cannot change the feature of SRPW of having an optimum standoff distance, but it slightly changes the oscillating frequency of the jet. It is also found that feeding pipe diameter significantly affects the magnitudes of pressure oscillation peak and amplitude, largely depending on the pump pressure and standoff distance. The enhancement or attenuation of the pressure oscillation peak and amplitude can be differently affected by the same feeding pipe diameter.

  5. Facilitative-competitive interactions in an old-growth forest: the importance of large-diameter trees as benefactors and stimulators for forest community assembly.

    Directory of Open Access Journals (Sweden)

    Andreas Fichtner

    Full Text Available The role of competition in tree communities is increasingly well understood, while little is known about the patterns and mechanisms of the interplay between above- and belowground competition in tree communities. This knowledge, however, is crucial for a better understanding of community dynamics and developing adaptive near-natural management strategies. We assessed neighbourhood interactions in an unmanaged old-growth European beech (Fagus sylvatica forest by quantifying variation in the intensity of above- (shading and belowground competition (crowding among dominant and co-dominant canopy beech trees during tree maturation. Shading had on average a much larger impact on radial growth than crowding and the sensitivity to changes in competitive conditions was lowest for crowding effects. We found that each mode of competition reduced the effect of the other. Increasing crowding reduced the negative effect of shading, and at high levels of shading, crowding actually had a facilitative effect and increased growth. Our study demonstrates that complementarity in above- and belowground processes enable F. sylvatica to alter resource acquisition strategies, thus optimising tree radial growth. As a result, competition seemed to become less important in stands with a high growing stock and tree communities with a long continuity of anthropogenic undisturbed population dynamics. We suggest that growth rates do not exclusively depend on the density of potential competitors at the intraspecific level, but on the conspecific aggregation of large-diameter trees and their functional role for regulating biotic filtering processes. This finding highlights the potential importance of the rarely examined relationship between the spatial aggregation pattern of large-diameter trees and the outcome of neighbourhood interactions, which may be central to community dynamics and the related forest ecosystem services.

  6. Smelting of high-quality boiler steel in large-load arc furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Kablukovskij, A F; Breus, V M; Tyurin, E I; Khristich, V D; Dumchev, Ya P [Tsentral' nyj Nauchno-Issledovatel' skij Inst. Chernoj Metallurgii, Moscow (USSR)

    1975-02-01

    High-grade steel can be obtained in large-capacity furnaces if the smelting technology used takes account of the size of the aggregates, the course of the metal fusion process, interaction with slag, furnace atmosphere, reducing agents, and other process characteristics. 12Kh1MF boiler steel smelted in a 100-ton electric arc furnace by an oxidizing process with oxygen bath blow and cast by the siphon method into 6.5-ton ingots using a slag-forming mixture (240 mm diameter billets and 219 to 245 mm diameter tubes) is satisfactory with regard to macro and microstructure, oxygen and nonmetallic oxide inclusion content, and mechanical properties. The stress rupture strength of 10/sup 5/ h at 570/sup 0/C is similar to that of open-hearth steel. Sulfides larger than a 3.5 spheroid have been detected in it. The nitrogen content of the electric steel is 0.0090 to 0.0120%, which is somewhat greater than usual in open-hearth metal. Of the oxygen inclusions in the steel, spinel-alumina predominates. Large inclusions were represented mainly by brittle silicates which appeared to be of exogenous origin.

  7. Green synthesis of highly concentrated aqueous colloidal solutions of large starch-stabilised silver nanoplatelets.

    Science.gov (United States)

    Cheng, Fei; Betts, Jonathan W; Kelly, Stephen M; Hector, Andrew L

    2015-01-01

    A simple, environmentally friendly and cost-effective method has been developed to prepare a range of aqueous silver colloidal solutions, using ascorbic acid as a reducing agent, water-soluble starch as a combined crystallising, stabilising and solubilising agent, and water as the solvent. The diameter of silver nanoplatelets increases with higher concentrations of AgNO3 and starch. The silver nanoparticles are also more uniform in shape the greater the diameter of the nanoparticles. Colloidal solutions with a very high concentration of large, flat, hexagonal silver nanoplatelets (~230 nm in breadth) have been used to deposit and fix an antibacterial coating of these large starch-stabilised silver nanoplates on commercial cotton fibres, using a simple dip-coating process using water as the solvent, in order to study the dependence of the antibacterial properties of these nanoplatelets on their size. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Diameter-dependent release of a cisplatin pro-drug from small and large functionalized carbon nanotubes

    Science.gov (United States)

    Muzi, Laura; Ménard-Moyon, Cécilia; Russier, Julie; Li, Jian; Chin, Chee Fei; Ang, Wee Han; Pastorin, Giorgia; Risuleo, Gianfranco; Bianco, Alberto

    2015-03-01

    promote drug accumulation inside cells in comparison with treatment with the free complex. To conclude, our study shows that CNTs are promising nanocarriers to improve the accumulation of a chemotherapeutic drug and its slow release inside tumor cells, by tuning the CNT diameter, without inducing a high inflammatory response.The use of platinum-based chemotherapeutic drugs in cancer therapy still suffers from severe disadvantages, such as lack of appropriate selectivity for tumor tissues and insurgence of multi-drug resistance. Moreover, drug efficacy can be attenuated by several mechanisms such as premature drug inactivation, reduced drug uptake inside cells and increased drug efflux once internalized. The use of functionalized carbon nanotubes (CNTs) as chemotherapeutic drug delivery systems is a promising strategy to overcome such limitations due to their ability to enhance cellular internalization of poorly permeable drugs and thus increase the drug bioavailability at the diseased site, compared to the free drug. Furthermore, the possibility to encapsulate agents in the nanotubes' inner cavity can protect the drug from early inactivation and their external functionalizable surface is useful for selective targeting. In this study, a hydrophobic platinum(iv) complex was encapsulated within the inner space of two different diameter functionalized multi-walled CNTs (Pt(iv)@CNTs). The behavior of the complexes, compared to the free drug, was investigated on both HeLa human cancer cells and RAW 264.7 murine macrophages. Both CNT samples efficiently induced cell death in HeLa cancer cells 72 hours after the end of exposure to CNTs. Although the larger diameter CNTs were more cytotoxic on HeLa cells compared to both the free drug and the smaller diameter nanotubes, the latter allowed a prolonged release of the encapsulated drug, thus increasing its anticancer efficacy. In contrast, both Pt(iv)@CNT constructs were poorly cytotoxic on macrophages and induced negligible cell

  9. SAFT and TOFD evaluation for ultrasonic testing of longitudinal welds in large-diameter pipes; SAFT- und TOFD-Auswertung fuer die Ultraschall-Schweissnahtpruefung von laengsnahtgeschweissten Grossrohren

    Energy Technology Data Exchange (ETDEWEB)

    Rieder, Hans; Dillhoefer, Alexander; Spies, Martin [Fraunhofer-Institut fuer Techno- und Wirtschaftsmathematik ITWM, Kaiserslautern (Germany); Graff, Alfred; Orth, Thomas [Salzgitter Mannesmann Forschung GmbH, Duisburg (Germany); Kersting, Thomas [Europipe GmbH, Muelheim an der Ruhr (Germany). Werk Muelheim

    2010-07-01

    The authors present a mobile multichannel system for testing of longitudinal welds in large-diameter tubes. The prototype was designed for in situ inspection of longitudinal welds using transversal and longitudinal waves impacting at an angle from both sides in combined SE and IE operation. The reconstruction and imaging software enables SAFT calculations for all surface curves and superposition of the SAFT reconstructions from both sides into a general image of the weld. This includes superposition of the TOFD test data with a suitable evaluation and assessment concept. Details are presented, as are test results on test pieces for validation and on longitudinal welds in large-diameter tubes. (orig.)

  10. Laser direct writing using submicron-diameter fibers.

    Science.gov (United States)

    Tian, Feng; Yang, Guoguang; Bai, Jian; Xu, Jianfeng; Hou, Changlun; Liang, Yiyong; Wang, Kaiwei

    2009-10-26

    In this paper, a novel direct writing technique using submicron-diameter fibers is presented. The submicron-diameter fiber probe serves as a tightly confined point source and it adopts micro touch mode in the process of writing. The energy distribution of direct writing model is analyzed by Three-Dimension Finite-Difference Time-Domain method. Experiments demonstrate that submicron-diameter fiber direct writing has some advantages: simple process, 350-nm-resolution (lower than 442-nm-wavelength), large writing area, and controllable width of lines. In addition, by altering writing direction of lines, complex submicron patterns can be fabricated.

  11. High-resolution tracking using large capillary bundles filled with liquid scintillator

    CERN Document Server

    Annis, P; Benussi, L; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Van Dantzig, R; Dupraz, J P; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Feyt, J; Frekers, D; Frenkel, A; Galeazzi, F; Garufi, F; Goldberg, J; Golovkin, S V; Gorin, A M; Grégoire, G; Harrison, K; Höpfner, K; Holtz, K; Konijn, J; Kozarenko, E N; Kreslo, I E; Kushnirenko, A E; Liberti, B; Martellotti, G; Medvedkov, A M; Michel, L; Migliozzi, P; Mommaert, C; Mondardini, M R; Panman, J; Penso, G; Petukhov, Yu P; Rondeshagen, D; Siegmund, W P; Tyukov, V E; Van Beek, G; Vasilchenko, V G; Vilain, P; Visschers, J L; Wilquet, G; Winter, Klaus; Wolff, T; Wörtche, H J; Wong, H; Zimyn, K V

    2000-01-01

    We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of \\hbox{$\\approx 10^6$} capillaries with \\hbox{20$-$25 $\\mu$m} diameter and \\hbox{0.9$-$1.8 m} length, have been tested, and a spatial resolution of the order of \\hbox{20$-$40 $\\mu$m} has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were $\\sim$ 8 hits/mm at the readout window, and \\hbox{$\\sim$ 3 ...

  12. Comparison of height-diameter models based on geographically weighted regressions and linear mixed modelling applied to large scale forest inventory data

    Energy Technology Data Exchange (ETDEWEB)

    Quirós Segovia, M.; Condés Ruiz, S.; Drápela, K.

    2016-07-01

    Aim of the study: The main objective of this study was to test Geographically Weighted Regression (GWR) for developing height-diameter curves for forests on a large scale and to compare it with Linear Mixed Models (LMM). Area of study: Monospecific stands of Pinus halepensis Mill. located in the region of Murcia (Southeast Spain). Materials and Methods: The dataset consisted of 230 sample plots (2582 trees) from the Third Spanish National Forest Inventory (SNFI) randomly split into training data (152 plots) and validation data (78 plots). Two different methodologies were used for modelling local (Petterson) and generalized height-diameter relationships (Cañadas I): GWR, with different bandwidths, and linear mixed models. Finally, the quality of the estimated models was compared throughout statistical analysis. Main results: In general, both LMM and GWR provide better prediction capability when applied to a generalized height-diameter function than when applied to a local one, with R2 values increasing from around 0.6 to 0.7 in the model validation. Bias and RMSE were also lower for the generalized function. However, error analysis showed that there were no large differences between these two methodologies, evidencing that GWR provides results which are as good as the more frequently used LMM methodology, at least when no additional measurements are available for calibrating. Research highlights: GWR is a type of spatial analysis for exploring spatially heterogeneous processes. GWR can model spatial variation in tree height-diameter relationship and its regression quality is comparable to LMM. The advantage of GWR over LMM is the possibility to determine the spatial location of every parameter without additional measurements. Abbreviations: GWR (Geographically Weighted Regression); LMM (Linear Mixed Model); SNFI (Spanish National Forest Inventory). (Author)

  13. On-line ultrasonic inside-diameter control system for Zircaloy

    International Nuclear Information System (INIS)

    Tanaka, Y.; Fujii, N.; Komatsu, M.; Kubota, H.

    1984-01-01

    An ultrasonic inside-diameter (ID) control system was used during the final etching process for producing Zircaloy nuclear fuel cladding tubes. This results in establishing automatic inside-diameter control during etching with an automatic etching system. In this system, the inside-diameter at the center point in the length of each tube is continuously measured with the ultrasonic inside-diameter measuring equipment during the etching process and the etching is automatically stopped by a signal from the control equipment when the inside-diameter reaches the target value. This made the final etching process economical and suitable for large-scale production, having an equal or better level at the inside-diameter of tubes etched with this system than those made by a process controlled by an air-micrometer

  14. A feasible injection molding technique for the manufacturing of large diameter aspheric plastic lenses

    Science.gov (United States)

    Shieh, Jen-Yu; Wang, Luke K.; Ke, Shih-Ying

    2010-07-01

    A computer aided engineering (CAE) tool-assisted technique, using Moldex3D and aspheric analysis utility (AAU) software in a polycarbonate injection molding design, is proposed to manufacture large diameter aspheric plastic lenses. An experiment is conducted to verify the applicability/feasibility of the proposed technique. Using the preceding two software tools, these crucial process parameters associated with the surface profile errors and birefringence of a molded lens can be attainable. The strategy adopted here is to use the actual quantity of shrinkage after an injection molding trial of an aspherical plastic lens as a reference to perform the core shaping job while keeping the coefficients of aspheric surface, radius, and conic constant unchanged. The design philosophy is characterized by using the CAE tool as a guideline to pursue the best symmetry condition, followed by injection molding trials, to accelerate a product’s developmental time. The advantages are less design complexity and shorter developmental time for a product.

  15. Large Aperture "Photon Bucket" Optical Receiver Performance in High Background Environments

    Science.gov (United States)

    Vilnrotter, Victor A.; Hoppe, D.

    2011-01-01

    The potential development of large aperture groundbased "photon bucket" optical receivers for deep space communications, with acceptable performance even when pointing close to the sun, is receiving considerable attention. Sunlight scattered by the atmosphere becomes significant at micron wavelengths when pointing to a few degrees from the sun, even with the narrowest bandwidth optical filters. In addition, high quality optical apertures in the 10-30 meter range are costly and difficult to build with accurate surfaces to ensure narrow fields-of-view (FOV). One approach currently under consideration is to polish the aluminum reflector panels of large 34-meter microwave antennas to high reflectance, and accept the relatively large FOV generated by state-of-the-art polished aluminum panels with rms surface accuracies on the order of a few microns, corresponding to several-hundred micro-radian FOV, hence generating centimeter-diameter focused spots at the Cassegrain focus of 34-meter antennas. Assuming pulse-position modulation (PPM) and Poisson-distributed photon-counting detection, a "polished panel" photon-bucket receiver with large FOV will collect hundreds of background photons per PPM slot, along with comparable signal photons due to its large aperture. It is demonstrated that communications performance in terms of PPM symbol-error probability in high-background high-signal environments depends more strongly on signal than on background photons, implying that large increases in background energy can be compensated by a disproportionally small increase in signal energy. This surprising result suggests that large optical apertures with relatively poor surface quality may nevertheless provide acceptable performance for deep-space optical communications, potentially enabling the construction of cost-effective hybrid RF/optical receivers in the future.

  16. Design considerations for a large aperture high field superconducting dipole

    International Nuclear Information System (INIS)

    Harfoush, F.; Ankenbrandt, C.; Harrison, M.; Kerby, J.; Koepke, K.; Mantsch, P.; Nicol, T.; Riddiford, A.; Theilacker, J.

    1989-03-01

    The final phase of the Fermilab upgrade proposal calls for a new ring of superconducting magnets to be placed in the existing Main Accelerator tunnel. The goal of this design study is to specify a high field dipole (HFD) that is capable of supporting fixed target operation (ramping, resonant extraction) at a field of 6.6T (1.5 Tev) and colliding beam physics at 8.0T (1.8 Tev). The magnetic field quality at high field is set by the large amplitude orbits associated with resonant extraction. The field quality must therefore be at least as good as the existing Tevatron magnets which fulfill these criteria. The high fields and large aperture of this magnet result in large forces on the coil and collar assemblies. Therefore, the cold mass design must be able to sustain these forces while providing sufficient cooling to the coils during 4.2 K fixed target operation, and a minimum heat load during 1.8 K collider operation. The design work is still in progress but a cosine-theta, cold-iron dipole with a 70mm inner diameter coil has been tentatively adopted. This report presents details on the conductor and cable parameters, coil cross-section, projected manufacturing tolerances, iron yoke design, and cold mass assembly. 4 refs., 5 figs., 1 tab

  17. Design considerations for a large aperture high field superconducting dipole

    Energy Technology Data Exchange (ETDEWEB)

    Harfoush, F.; Ankenbrandt, C.; Harrison, M.; Kerby, J.; Koepke, K.; Mantsch, P.; Nicol, T.; Riddiford, A.; Theilacker, J.

    1989-03-01

    The final phase of the Fermilab upgrade proposal calls for a new ring of superconducting magnets to be placed in the existing Main Accelerator tunnel. The goal of this design study is to specify a high field dipole (HFD) that is capable of supporting fixed target operation (ramping, resonant extraction) at a field of 6.6T (1.5 Tev) and colliding beam physics at 8.0T (1.8 Tev). The magnetic field quality at high field is set by the large amplitude orbits associated with resonant extraction. The field quality must therefore be at least as good as the existing Tevatron magnets which fulfill these criteria. The high fields and large aperture of this magnet result in large forces on the coil and collar assemblies. Therefore, the cold mass design must be able to sustain these forces while providing sufficient cooling to the coils during 4.2 K fixed target operation, and a minimum heat load during 1.8 K collider operation. The design work is still in progress but a cosine-theta, cold-iron dipole with a 70mm inner diameter coil has been tentatively adopted. This report presents details on the conductor and cable parameters, coil cross-section, projected manufacturing tolerances, iron yoke design, and cold mass assembly. 4 refs., 5 figs., 1 tab.

  18. Large high current density superconducting solenoids for use in high energy physics experiments

    International Nuclear Information System (INIS)

    Green, M.A.; Eberhard, P.H.; Taylor, J.D.

    1976-05-01

    Very often the study of high energy physics in colliding beam storage-rings requires a large magnetic field volume in order to detect and analyze charged particles which are created from the collision of two particle beams. Large superconducting solenoids which are greater than 1 meter in diameter are required for this kind of physics. In many cases, interesting physics can be done outside the magnet coil, and this often requires that the amount of material in the magnet coil be minimized. As a result, these solenoids should have high current density (up to 10 9 A m -2 ) superconducting windings. The methods commonly used to stabilize large superconducting magnets cannot be employed because of this need to minimize the amount of material in the coils. A description is given of the Lawrence Berkeley Laboratory program for building and testing prototype solenoid magnets which are designed to operate at coil current densities in excess of 10 9 A m -2 with magnetic stored energies which are as high as 1.5 Megajoules per meter of solenoid length. The coils use intrinsically stable multifilament Nb--Ti superconductors. Control of the magnetic field quench is achieved by using a low resistance aluminum bore tube which is inductively coupled to the coil. The inner cryostat is replaced by a tubular cooling system which carries two phase liquid helium. The magnet coil, the cooling tubes, and aluminum bore tube are cast in epoxy to form a single unified magnet and cryogenic system which is about 2 centimeters thick. The results of the magnet coil tests are discussed

  19. Siting of large diameter well type repositories for the central region of Russia

    International Nuclear Information System (INIS)

    Dmitriev, A.S.; Tkachenko, A.V.; Prozorov, L.B.; Guskov, A.V.; Korneva, S.A.

    2002-01-01

    To date only 14 from 16 RADON facilities are in operation. Most of them have not more than about 10% of their repositories free and available for new upcoming radioactive waste. Construction of new repositories and selection of new perspective sites is very actual problem for RAW management in Russia now. Near surface repositories are considered to be acceptable for storage of wastes with low and intermediate activity levels (LILW), which decay to safe levels in some hundreds of years. However, the experience with LILW isolation in the near surface facilities in Russia has shown that a lot of operational and natural factors impact on the engineered barriers and may cause failure of the isolation. In addition, the exploitation of the old repositories and construction of new ones require more area. Significant increase in LILW isolation reliability and area saving may be achieved by wastes disposal/storage in Large Diameter Wells (LDW), drilled in homogeneous sediments with low permeable properties. It could be considered as an intermediate between near-surface and geological repositories, and its specific features should be taken into account when choosing new sites for RAW disposal or long-term storage. (author)

  20. Evaluation of the Load-Displacement Relationships for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Brodbaek, K. T.; Moller, M.

    2009-01-01

    For laterally loaded piles in sand with diameters up to 6 m, e.g. monopiles used as foundations for offshore wind turbines, there is no approved design procedure. The p-y curve method, given in offshore design regulations, is usually employed for the design of monopiles. However, this method was ...

  1. Development of Muon Drift-Tube Detectors for High-Luminosity Upgrades of the Large Hadron Collider

    CERN Document Server

    Bittner, B; Kortner, O.; Kroha, H.; Legger, F.; Richter, R.; Biebel, O.; Engl, A.; Hertenberger, R.; Rauscher, F.

    2016-01-01

    The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance, counting rates of 1.7 kHz/square cm are reached at the LHC design luminosity. For high-luminosity upgrades of the LHC, up to 10 times higher background rates are expected which require replacement of the muon chambers in the critical detector regions. Tests at the CERN Gamma Irradiation Facility showed that drift-tube detectors with 15 mm diameter aluminum tubes operated with Ar:CO2 (93:7) gas at 3 bar and a maximum drift time of about 200 ns provide e?cient and high-resolution muon tracking up to the highest expected rates. For 15 mm tube diameter, space charge e?ects deteriorating the spatial resolution at high rates are strongly suppressed. The sense wires have to be positioned in the chamber with an accuracy of better than 50 ?micons in order to achieve the desired spatial...

  2. Large scale high strain-rate tests of concrete

    Directory of Open Access Journals (Sweden)

    Kiefer R.

    2012-08-01

    Full Text Available This work presents the stages of development of some innovative equipment, based on Hopkinson bar techniques, for performing large scale dynamic tests of concrete specimens. The activity is centered at the recently upgraded HOPLAB facility, which is basically a split Hopkinson bar with a total length of approximately 200 m and with bar diameters of 72 mm. Through pre-tensioning and suddenly releasing a steel cable, force pulses of up to 2 MN, 250 μs rise time and 40 ms duration can be generated and applied to the specimen tested. The dynamic compression loading has first been treated and several modifications in the basic configuration have been introduced. Twin incident and transmitter bars have been installed with strong steel plates at their ends where large specimens can be accommodated. A series of calibration and qualification tests has been conducted and the first real tests on concrete cylindrical specimens of 20cm diameter and up to 40cm length have commenced. Preliminary results from the analysis of the recorded signals indicate proper Hopkinson bar testing conditions and reliable functioning of the facility.

  3. High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Gondal, M.A.; Khiari, F.Z.; Dastageer, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Maslehuddin, M.M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

  4. US Intergroup Anal Carcinoma Trial: Tumor Diameter Predicts for Colostomy

    Science.gov (United States)

    Ajani, Jaffer A.; Winter, Kathryn A.; Gunderson, Leonard L.; Pedersen, John; Benson, Al B.; Thomas, Charles R.; Mayer, Robert J.; Haddock, Michael G.; Rich, Tyvin A.; Willett, Christopher G.

    2009-01-01

    Purpose The US Gastrointestinal Intergroup Radiation Therapy Oncology Group 98-11 anal carcinoma trial showed that cisplatin-based concurrent chemoradiotherapy resulted in a significantly higher rate of colostomy compared with mitomycin-based therapy. Established prognostic variables for patients with anal carcinoma include tumor diameter, clinical nodal status, and sex, but pretreatment variables that would predict the likelihood of colostomy are unknown. Methods A secondary analysis was performed by combining patients in the two treatment arms to evaluate whether new predictive and prognostic variables would emerge. Univariate and multivariate analyses were carried out to correlate overall survival (OS), disease-free survival, and time to colostomy (TTC) with pretreatment and treatment variables. Results Of 682 patients enrolled, 644 patients were assessable and analyzed. In the multivariate analysis, tumor-related prognosticators for poorer OS included node-positive cancer (P ≤ .0001), large (> 5 cm) tumor diameter (P = .01), and male sex (P = .016). In the treatment-related categories, cisplatin-based therapy was statistically significantly associated with a higher rate of colostomy (P = .03) than was mitomycin-based therapy. In the pretreatment variables category, only large tumor diameter independently predicted for TTC (P = .008). Similarly, the cumulative 5-year colostomy rate was statistically significantly higher for large tumor diameter than for small tumor diameter (Gray's test; P = .0074). Clinical nodal status and sex were not predictive of TTC. Conclusion The combined analysis of the two arms of RTOG 98-11, representing the largest prospective database, reveals that tumor diameter (irrespective of the nodal status) is the only independent pretreatment variable that predicts TTC and 5-year colostomy rate in patients with anal carcinoma. PMID:19139424

  5. Measurements of stem diameter: implications for individual- and stand-level errors.

    Science.gov (United States)

    Paul, Keryn I; Larmour, John S; Roxburgh, Stephen H; England, Jacqueline R; Davies, Micah J; Luck, Hamish D

    2017-08-01

    Stem diameter is one of the most common measurements made to assess the growth of woody vegetation, and the commercial and environmental benefits that it provides (e.g. wood or biomass products, carbon sequestration, landscape remediation). Yet inconsistency in its measurement is a continuing source of error in estimates of stand-scale measures such as basal area, biomass, and volume. Here we assessed errors in stem diameter measurement through repeated measurements of individual trees and shrubs of varying size and form (i.e. single- and multi-stemmed) across a range of contrasting stands, from complex mixed-species plantings to commercial single-species plantations. We compared a standard diameter tape with a Stepped Diameter Gauge (SDG) for time efficiency and measurement error. Measurement errors in diameter were slightly (but significantly) influenced by size and form of the tree or shrub, and stem height at which the measurement was made. Compared to standard tape measurement, the mean systematic error with SDG measurement was only -0.17 cm, but varied between -0.10 and -0.52 cm. Similarly, random error was relatively large, with standard deviations (and percentage coefficients of variation) averaging only 0.36 cm (and 3.8%), but varying between 0.14 and 0.61 cm (and 1.9 and 7.1%). However, at the stand scale, sampling errors (i.e. how well individual trees or shrubs selected for measurement of diameter represented the true stand population in terms of the average and distribution of diameter) generally had at least a tenfold greater influence on random errors in basal area estimates than errors in diameter measurements. This supports the use of diameter measurement tools that have high efficiency, such as the SDG. Use of the SDG almost halved the time required for measurements compared to the diameter tape. Based on these findings, recommendations include the following: (i) use of a tape to maximise accuracy when developing allometric models, or when

  6. A clustering analysis of lipoprotein diameters in the metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Frazier-Wood Alexis C

    2011-12-01

    Full Text Available Abstract Background The presence of smaller low-density lipoproteins (LDL has been associated with atherosclerosis risk, and the insulin resistance (IR underlying the metabolic syndrome (MetS. In addition, some research has supported the association of very low-, low- and high-density lipoprotein (VLDL HDL particle diameters with components of the metabolic syndrome (MetS, although this has been the focus of less research. We aimed to explore the relationship of VLDL, LDL and HDL diameters to MetS and its features, and by clustering individuals by their diameters of VLDL, LDL and HDL particles, to capture information across all three fractions of lipoprotein into a unified phenotype. Methods We used nuclear magnetic resonance spectroscopy measurements on fasting plasma samples from a general population sample of 1,036 adults (mean ± SD, 48.8 ± 16.2 y of age. Using latent class analysis, the sample was grouped by the diameter of their fasting lipoproteins, and mixed effects models tested whether the distribution of MetS components varied across the groups. Results Eight discrete groups were identified. Two groups (N = 251 were enriched with individuals meeting criteria for the MetS, and were characterized by the smallest LDL/HDL diameters. One of those two groups, one was additionally distinguished by large VLDL, and had significantly higher blood pressure, fasting glucose, triglycerides, and waist circumference (WC; P Conclusions While small LDL diameters remain associated with IR and the MetS, the occurrence of these in conjunction with a shift to overall larger VLDL diameter may identify those with the highest fasting glucose, TG and WC within the MetS. If replicated, the association of this phenotype with more severe IR-features indicated that it may contribute to identifying of those most at risk for incident type II diabetes and cardiometabolic disease.

  7. Utilization of the MPI Process for in-tank solidification of heel material in large-diameter cylindrical tanks

    Energy Technology Data Exchange (ETDEWEB)

    Kauschinger, J.L.; Lewis, B.E.

    2000-01-01

    A major problem faced by the US Department of Energy is remediation of sludge and supernatant waste in underground storage tanks. Exhumation of the waste is currently the preferred remediation method. However, exhumation cannot completely remove all of the contaminated materials from the tanks. For large-diameter tanks, amounts of highly contaminated ``heel'' material approaching 20,000 gal can remain. Often sludge containing zeolite particles leaves ``sand bars'' of locally contaminated material across the floor of the tank. The best management practices for in-tank treatment (stabilization and immobilization) of wastes require an integrated approach to develop appropriate treatment agents that can be safely delivered and mixed uniformly with sludge. Ground Environmental Services has developed and demonstrated a remotely controlled, high-velocity jet delivery system termed, Multi-Point-Injection (MPI). This robust jet delivery system has been field-deployed to create homogeneous monoliths containing shallow buried miscellaneous waste in trenches [fiscal year (FY) 1995] and surrogate sludge in cylindrical (FY 1998) and long, horizontal tanks (FY 1999). During the FY 1998 demonstration, the MPI process successfully formed a 32-ton uniform monolith of grout and waste surrogates in about 8 min. Analytical data indicated that 10 tons of zeolite-type physical surrogate were uniformly mixed within a 40-in.-thick monolith without lifting the MPI jetting tools off the tank floor. Over 1,000 lb of cohesive surrogates, with consistencies similar to Gunite and Associated Tank (GAAT) TH-4 and Hanford tank sludges, were easily intermixed into the monolith without exceeding a core temperature of 100 F during curing.

  8. Maximum tumor diameter is not an independent prognostic factor in high-risk localized prostate cancer

    NARCIS (Netherlands)

    Oort, van I.M.; Witjes, J.A.; Kok, D.E.G.; Kiemeney, L.A.; Hulsbergen-van de Kaa, C.A.

    2008-01-01

    Previous studies suggest that maximum tumor diameter (MTD) is a predictor of recurrence in prostate cancer (PC). This study investigates the prognostic value of MTD for biochemical recurrence (BCR) in patients with PC, after radical prostatectomy (RP), with emphasis on high-risk localized prostate

  9. Large-diameter balloon dilation for the treatment of achalasia of cardia: an analysis of mid-to-long term efficacy in 80 cases

    International Nuclear Information System (INIS)

    Song Jinwen; Yin Jianguo; Yang Yan; Liu Xiaohong; Wang Zhihong

    2011-01-01

    Objective: To discuss the technical points of large-diameter (40 mm) balloon dilation in treating achalasia of cardia, and to assess its mid-to-long term efficacy. Methods: A total of 80 patients of achalasia of cardia with a disease course of 3-23 years were enrolled in this study. According to Mellow-Pinkas standard of the dysphagia grading (from 0 to Ⅳ), the patients were classified into grade Ⅰ (n=6), grade Ⅱ (n=60) and grade Ⅲ (n=14). The diagnosis was confirmed by barium meal examination in all patients. Under spraying anesthesia of pharyngeal portion with 2% lidocaine, the intensified guide wire was inserted into the stomach through mouth under fluoroscopy guidance. The Boston's balloon (40 mm in diameter) was pushed along the guidewire to the stricture site at the cardia and was gradually inflated with 15% contrast medium by using the 'graded intermittent inflation' technique. Namely, the balloon was inflated to a maximum diameter and was kept in this condition for five minute, and then the balloon was deflated for 3-5 minutes. The above procedure was repeated 2-3 times. For the severe stricture, pre-dilatation with 20-25 mm diameter balloon was carried out. As a routine, postoperative measures to prevent possible bleeding and infection were adopted. The patient was allowed to take cool liquid diet 2-3 hours after the procedure, to have semi-liquid diet within three days and then to take normal diet. The patients were followed up for 2-10 years. Results: The balloon insertion was technically successful in all of the 80 patients. The success rate of single and twice manipulations was 96.3% (77/80) and 3.7% (3/80), respectively. Postoperative rupture of the cardia region was seen in one patient, and surgical repair had to be carried out. The follow-up time ranged from 2 years to 10 years (mean 6.27 years). No recurrent stenosis occurred in all patients. The remission rate of dysphagia was 100%. The swallowing function returned to normal in 90% of

  10. Thermal analysis of large diameter container (LDC) with alternate loadings of KE Basin sludge

    International Nuclear Information System (INIS)

    MILDON, D.T.

    2003-01-01

    A thermal analysis was performed to determine temperature distribution and hydrogen generation for a Large Diameter Container (LDC) having a two layer load configuration made up of a lower layer, consisting of sludge from the weasel pit, and an upper layer, consisting of the KE Basin canister sludge. For each alternate loading, the response of the LDC during shipping and storage in a T Plant cell was determined. Results for various alternate loadings were compared to the base case previously reported in SNF--9955 [Crea, 2002], 4 identical batches each with 60% floor, 40% canister sludge. Results for various cases are summarized in Table 5 and transient histories for each case are contained in figures as noted in the table. The thermal response and hydrogen generation rate of the base case bounds all alternate loadings except the third alternate loading, where 0.8 m 3 of canister sludge is loaded on the top of 1.2 m 3 of weasel pit sludge. For this case, the peak sludge temperature exceeded 100 C during shipping after 6.8 days (Note: sludge boiling does not occur in any case because the LDC pressurizes during transport and interstitial water is never saturated)

  11. Economic feasibility of products from inland West small-diameter timber

    Science.gov (United States)

    Spelter Henry; Rong Wang; Peter Ince

    1996-01-01

    A large part of the forests located in the Rocky Mountain region of the U.S. West (inland West) is characterized by densely packed, small-diameter stands. The purpose of this study was to examine the economic feasibility of using small-diameter material from this resource to manufacture various wood products: oriented strandboard (OSB), stud lumber, random-length...

  12. Does pan diameter influence carbon monoxide levels during heating of water to boiling point with a camping stove?

    Science.gov (United States)

    Leigh-Smith, Simon; Stevenson, Richard; Watt, Martin; Watt, Ian; McFadyen, Angus; Grant, Stan

    2004-01-01

    To determine whether pan diameter influences carbon monoxide (CO) concentration during heating of water to boiling point with a camping stove. The hypothesis was that increasing pan diameter increases CO concentration because of greater flame dispersal and a larger flame. This was a randomized, prospective study. A Coleman Dual Fuel 533 stove was used to heat pans of water to boiling point, with CO concentration monitored every 30 seconds for 5 minutes. The stove was inside a partially ventilated 200-L cardboard box model that was inside an environmental chamber at -6 degrees C. Water temperature, water volume, and flame characteristics were all standardized. Ten trials were performed for each of 2 pan diameters (base diameters of 165 mm [small] and 220 mm [large]). There was a significant difference (P = .002) between the pans for CO levels at each measurement interval from 60 seconds onward. These differences were markedly larger after 90 seconds, with a mean difference of 185 ppm (95% CI 115, 276 ppm) for all the results from 120 seconds onwards. This study has shown that there is significantly higher CO production with a large-diameter pan compared with a small-diameter pan. These findings were evident by using a camping stove to heat water to boiling point when a maximum blue flame was present throughout. Thus, in enclosed environments it is recommended that small-diameter pans be used in an attempt to prevent high CO levels.

  13. Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.

    Science.gov (United States)

    Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

  14. Development of large-area high-temperature fixed-point blackbodies for photometry and radiometry

    Science.gov (United States)

    Khlevnoy, Boris; Grigoryeva, Irina; Anhalt, Klaus; Waehmer, Martin; Ivashin, Evgeniy; Otryaskin, Denis; Solodilov, Maxim; Sapritsky, Victor

    2018-04-01

    Large-area high-temperature fixed-point (HTFP) blackbodies with working temperatures of approximately 2748 K and 3021 K, based on an Re-C eutectic and a WC-C peritectic respectively, have been developed and investigated. The blackbodies have an emissivity of 0.9997, show high-quality phase-transition plateaus and have high repeatability of the melting temperatures, but demonstrate temperature differences (from 0.2 K to 0.6 K) compared with small-cell blackbodies of the same HTFP. We associate these temperature differences with the temperature drop effect, which may differ from cell to cell. The large radiating cavity diameter of 14 mm allows developed HTFP blackbodies to be used for photometric and radiometric applications in irradiance mode with uncertainties as small as 0.12% (k  =  1) in the visible. A photometer and an irradiance-mode filter radiometer (visible range), previously calibrated at VNIIOFI, were used to measure illuminance and irradiance of the HTFP blackbodies equipped with a precise outer aperture. The values measured by the detectors agreed with those based on the blackbody calculation to within 0.2%. The large-area HTFP blackbodies will be used in a joint PTB-VNIIOFI experiment on measuring thermodynamic temperature.

  15. Experimental use of large diameter boreholes in clay deposits for radioactive waste storage

    International Nuclear Information System (INIS)

    Dmitriev, S.; Litinsky, Y.; Tkachenko, A.; Guskov, A.

    2010-01-01

    Document available in extended abstract form only. Application of radioactive substances in industry, medicine and scientific research leads to generation of radioactive waste. The problem of improving reliability of isolation of the radioactive waste is becoming more acute with each passing year, and requirements for ecological safety are getting more and more stringent. Near surface repositories are usually considered to be acceptable for storage of waste with short lived radionuclides of low and intermediate activity level (LILW). However, the experience with LILW isolation in the near surface facilities in Russia has shown that a lot of operational and natural factors impact on the engineered barriers, and in case of traditional near surface repositories can cause failure of the isolation and discharge of radionuclides into near field. Operation of the old repositories with already contaminated surroundings and construction of similar new facilities require more and more area. SUE MosSIA 'RADON' from early 60-s was responsible for development of new approaches for waste treatment and long term storage. In accordance with this direction, research and experimental work is carried out both in field of upgrading safety for typical near surface repository constructions and in developing new repository types. Significant increase of LILW isolation reliability and land saving could be achieved by use of large diameter boreholes (LDB) drilled in clayey deposits for waste storage. Due to the depth of the borehole and depth of waste package emplacement, this type of facility can be considered as near surface facility. To date technology of LDB construction and its experimental use is being conducted in SUE Mos SIA 'Radon'. The diameter of a LDB type repository may range from 1 to 6 m depending on drilling rig capabilities and parameters of the repository in whole. The depth of the boreholes should depend on geological and hydro-geological conditions

  16. Comparison of Fixed Diameter-Limit and Selection Cutting in Northern Conifers

    Science.gov (United States)

    Laura S. Kenefic; Paul E. Sendak; John C. Brissette

    2005-01-01

    Diameter-limit cutting is a common type of harvest in which all merchantable trees above specific size thresholds are removed. Despite a long history of application, controlled experiments of these harvests are rare and the cumulative effects of repeated diameter-limit cuts are largely unknown. The Penobscot Experimental Forest in Maine is the location of a long-term...

  17. Safety characteristics of mid-sized MOX fueled liquid metal reactor core of high converter type in the initiating phase of unprotected loss of flow accident. Effect of low specific fuel power density on ULOF behavior brought by employment of large diameter fuel pins

    International Nuclear Information System (INIS)

    Ishida, Masayoshi; Kawada, Kenichi; Niwa, Hajime

    2003-07-01

    Safety characteristics in core disruptive accidents (CDAs) of mid-sized MOX fueled liquid metal reactor core of high converter type have been examined by using the CDA initiating phase analysis code SAS4A. The design concept of high converter type reactor core has been studied as one of options in the category of sodium-cooled reactor in Phase II of Feasibility Study on Commercialized Fast Reactor Cycle System. An unprotected loss-of-flow accident (ULOF) has been selected as a representative CDA initiator for this study. A core concept of high converter type, which employed a large diameter fuel pin of 11.1 mm with 1.2 m core height to get a large fuel volume fraction in the core to achieve high internal conversion ratio was proposed in JFY2001. Each fuel subassembly of the core (abbreviated here as UPL120)was provided with an upper sodium plenum directly above the core to reduce the sodium void reactivity worth. Because of the large fuel pin diameter, average specific fuel power density (31 kW/kg-MOX) of UPL120 is about one half of those of conventional large MOX cores. The reactivity worth of sodium voiding is 6$ in the whole core, and -1$ in the all upper plenums. Initiating phase of ULOF accident in UPL120 under the conditions of nominal design and best estimate analysis resulted in a slightly super-prompt critical power burst. The causes of the super-prompt criticality have been identified twofold: (a) the low specific fuel power density of core reduced the effectiveness of prompt negative reactivity feedback of Doppler and axial fuel expansion effects upon increase in reactor power, and (b) the longer core height compared with conventional 1m cores brought, together with the lower specific power density, a remarkable delay in insertion of negative fuel dispersion reactivity after the onset of fuel disruption in sodium voided subassembly due to the lower linear heat rating in the top portion of the core. During the delay, burst-type fuel failures in sodium un

  18. Reference interval for the disc-macula distance to disc diameter ratio in a large population of healthy Japanese adults

    Science.gov (United States)

    Sato, Ken-ichi

    2017-01-01

    Abstract This study presents the calculated reference interval for the disc-to-macula distance to disc diameter ratio (DM:DD) based on a large population of healthy Japanese adults. A total of 308 consecutive, healthy Japanese adults were examined in this prospective observational study. Eighteen subjects were also excluded because of poor quality of the fundus photograph of one or both eyes; 290 (161 men and 129 women) were included in this study. For each subject, a color fundus photograph of one eye, either the right or left, was randomly selected and used for analysis. On the photograph, the distances between the fovea and the nearest temporal margin of the optic disc (Dft), and the two kinds of disc diameters (D1 and D2), which bisected at right angles and one of which was directed to the fovea (D1), were measured. DM:DD was estimated using the formula: (2Dft + D1)/(D1 + D2). The mean ± standard deviation of DM:DD was 2.91 ± 0.49 for men and 2.96 ± 0.54 for women; there was no sex difference (P = .78, Mann–Whitney U test). Also, almost no relationship was found between DM:DD and age (ρ = −.12, P = .04, Spearman's rank correlation coefficient). The data did not fit a normal distribution (P < .001, Kolmogorov–Smirnov test). The estimated reference interval for DM:DD corresponding to the 2.5th and 97.5th percentiles was 2.12 to 4.18. Using a nonparametric approach, the reference interval for DM:DD of a large population of healthy Japanese adults was calculated to be 2.12 to 4.18, regardless of age or sex. PMID:28403107

  19. Proposed high speed pellet injection system 'HIPEL' for Large Helical Device

    International Nuclear Information System (INIS)

    Sudo, S.; Kanno, M.; Kaneko, H.; Saka, S.; Shirai, T.; Baba, T.

    1993-11-01

    From the results of the simulation study including pellet ablation and 1-D transport code, it is found that a high speed pellet injector with pellet velocity of more than 3 km/s is necessary for the penetration of the pellet with diameter of 3 mm into the core region under the expected plasma condition of Large Helical Device (LHD) of heliotron/stellarator type with superconducting coils at NIFS in Japan. Therefore, a two stage pellet injector was constructed and tested successfully in order to obtain the pellet velocity range of 3 km/s. Based upon the above results, a high speed flexible multiple-pellet injection system 'HIPEL' for LHD is proposed. HIPEL consists of independent (1) 10 two-stage gun barrels and (2) 10 single-stage gun barrels. It has multi purposes such as refueling and flexible density profile control, diagnostics and the other functions. (author)

  20. Strain-Based Design Methodology of Large Diameter Grade X80 Linepipe

    Energy Technology Data Exchange (ETDEWEB)

    Lower, Mark D. [ORNL

    2014-04-01

    Continuous growth in energy demand is driving oil and natural gas production to areas that are often located far from major markets where the terrain is prone to earthquakes, landslides, and other types of ground motion. Transmission pipelines that cross this type of terrain can experience large longitudinal strains and plastic circumferential elongation as the pipeline experiences alignment changes resulting from differential ground movement. Such displacements can potentially impact pipeline safety by adversely affecting structural capacity and leak tight integrity of the linepipe steel. Planning for new long-distance transmission pipelines usually involves consideration of higher strength linepipe steels because their use allows pipeline operators to reduce the overall cost of pipeline construction and increase pipeline throughput by increasing the operating pressure. The design trend for new pipelines in areas prone to ground movement has evolved over the last 10 years from a stress-based design approach to a strain-based design (SBD) approach to further realize the cost benefits from using higher strength linepipe steels. This report presents an overview of SBD for pipelines subjected to large longitudinal strain and high internal pressure with emphasis on the tensile strain capacity of high-strength microalloyed linepipe steel. The technical basis for this report involved engineering analysis and examination of the mechanical behavior of Grade X80 linepipe steel in both the longitudinal and circumferential directions. Testing was conducted to assess effects on material processing including as-rolled, expanded, and heat treatment processing intended to simulate coating application. Elastic-plastic and low-cycle fatigue analyses were also performed with varying internal pressures. Proposed SBD models discussed in this report are based on classical plasticity theory and account for material anisotropy, triaxial strain, and microstructural damage effects

  1. High-Performance Carbon Dioxide Electrocatalytic Reduction by Easily Fabricated Large-Scale Silver Nanowire Arrays.

    Science.gov (United States)

    Luan, Chuhao; Shao, Yang; Lu, Qi; Gao, Shenghan; Huang, Kai; Wu, Hui; Yao, Kefu

    2018-05-17

    An efficient and selective catalyst is in urgent need for carbon dioxide electroreduction and silver is one of the promising candidates with affordable costs. Here we fabricated large-scale vertically standing Ag nanowire arrays with high crystallinity and electrical conductivity as carbon dioxide electroreduction catalysts by a simple nanomolding method that was usually considered not feasible for metallic crystalline materials. A great enhancement of current densities and selectivity for CO at moderate potentials was achieved. The current density for CO ( j co ) of Ag nanowire array with 200 nm in diameter was more than 2500 times larger than that of Ag foil at an overpotential of 0.49 V with an efficiency over 90%. The origin of enhanced performances are attributed to greatly increased electrochemically active surface area (ECSA) and higher intrinsic activity compared to those of polycrystalline Ag foil. More low-coordinated sites on the nanowires which can stabilize the CO 2 intermediate better are responsible for the high intrinsic activity. In addition, the impact of surface morphology that induces limited mass transportation on reaction selectivity and efficiency of nanowire arrays with different diameters was also discussed.

  2. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  3. Construction and testing of the two meter diameter TPC thin superconducting solenoid

    International Nuclear Information System (INIS)

    Green, M.A.; Eberhard, P.H.; Ross, R.R.; Taylor, J.D.

    1979-08-01

    High energy colliding beam physics often requires large detectors which contain large volumes of magnetic field. The TPC (Time Projection Chamber) experiment at PEP will use a 1.5T magnetic field within a cylindrical volume which is 2.04m in diameter bounded by iron poles which are separated by a gap of 3.25m. The TPC magnet, built in 1979 by the Lawrence Berkeley Laboratory (LBL), is the largest high current density superconducting magnet built to date. It is designed to operate at a current density of 7 x 10 8 Am -2 and a stored energy of 11MJ, and it is protected by shorted secondary windings during a quench. The paper describes the basic parameters of the TPC magnet and the results of the first subassembly tests at LBL

  4. Height-diameter allometry of tropical forest trees

    Science.gov (United States)

    T.R. Feldpausch; L. Banin; O.L. Phillips; T.R. Baker; S.L. Lewis; C.A. Quesada; K. Affum-Baffoe; E.J.M.M. Arets; N.J. Berry; M. Bird; E.S. Brondizio; P de Camargo; J. Chave; G. Djagbletey; T.F. Domingues; M. Drescher; P.M. Fearnside; M.B. Franca; N.M. Fyllas; G. Lopez-Gonzalez; A. Hladik; N. Higuchi; M.O. Hunter; Y. Iida; K.A. Salim; A.R. Kassim; M. Keller; J. Kemp; D.A. King; J.C. Lovett; B.S. Marimon; B.H. Marimon-Junior; E. Lenza; A.R. Marshall; D.J. Metcalfe; E.T.A. Mitchard; E.F. Moran; B.W. Nelson; R. Nilus; E.M. Nogueira; M. Palace; S. Patiño; K.S.-H. Peh; M.T. Raventos; J.M. Reitsma; G. Saiz; F. Schrodt; B. Sonke; H.E. Taedoumg; S. Tan; L. White; H. Woll; J. Lloyd

    2011-01-01

    Tropical tree height-diameter (H:D) relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical...

  5. Full standard triple wireless transmission over 50m large core diameter graded index POF

    NARCIS (Netherlands)

    Shi, Y.; Morant, M.; Tangdiongga, E.; Llorente, R.; Koonen, A.M.J.

    2011-01-01

    We demonstrated for the first time a successful radio-over-1mm core diameter plastic optical fibre transmission of three simultaneous full standard wireless signals. Up to 50-m long transmission distance employing an eye-safe vertical cavity surface emitting laser has been achieved. The transmission

  6. NEOWISE REACTIVATION MISSION YEAR TWO: ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Bauer, J.; Kramer, E. A.; Masiero, J.; Sonnett, S. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2016-09-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids (NEAs) and 8885 other asteroids. Of the NEAs, 84% NEAs did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within ±∼20% and ±∼40%, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large (>100 m), and have low albedos.

  7. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  8. 150 Mb/s wifi transmission over 50m large core diameter step index POF

    NARCIS (Netherlands)

    Shi, Y.; Nieto Munoz, M.; Okonkwo, C.M.; Boom, van den H.P.A.; Tangdiongga, E.; Koonen, A.M.J.

    2011-01-01

    We demonstrate successful transmission of WiFi signals over 50m step-index plastic optical fibre with 1mm core diameter employing an eye-safe resonant cavity light emitting diode and an avalanche photodetector. The EVM performance of 4.1% at signal data rate of 150Mb/s is achieved.

  9. Nuclear criticality safety calculational analysis for small-diameter containers

    International Nuclear Information System (INIS)

    LeTellier, M.S.; Smallwood, D.J.; Henkel, J.A.

    1995-11-01

    This report documents calculations performed to establish a technical basis for the nuclear criticality safety of favorable geometry containers, sometimes referred to as 5-inch containers, in use at the Portsmouth Gaseous Diffusion Plant. A list of containers currently used in the plant is shown in Table 1.0-1. These containers are currently used throughout the plant with no mass limits. The use of containers with geometries or material types other than those addressed in this evaluation must be bounded by this analysis or have an additional analysis performed. The following five basic container geometries were modeled and bound all container geometries in Table 1.0-1: (1) 4.32-inch-diameter by 50-inch-high polyethylene bottle; (2) 5.0-inch-diameter by 24-inch-high polyethylene bottle; (3) 5.25-inch-diameter by 24-inch-high steel can (open-quotes F-canclose quotes); (4) 5.25-inch-diameter by 15-inch-high steel can (open-quotes Z-canclose quotes); and (5) 5.0-inch-diameter by 9-inch-high polybottle (open-quotes CO-4close quotes). Each container type is evaluated using five basic reflection and interaction models that include single containers and multiple containers in normal and in credible abnormal conditions. The uranium materials evaluated are UO 2 F 2 +H 2 O and UF 4 +oil materials at 100% and 10% enrichments and U 3 O 8 , and H 2 O at 100% enrichment. The design basis safe criticality limit for the Portsmouth facility is k eff + 2σ < 0.95. The KENO study results may be used as the basis for evaluating general use of these containers in the plant

  10. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  11. Large-scale synthesis of high-purity well-aligned carbon nanotubes using pyrolysis of iron(II) phthalocyanine and acetylene

    Science.gov (United States)

    Liu, B. C.; Lee, T. J.; Lee, S. H.; Park, C. Y.; Lee, C. J.

    2003-08-01

    Well-aligned carbon nanotubes (CNTs) with high purity have been produced by pyrolysis of iron(II) phthalocyanine and acetylene at 800 °C. The synthesized CNTs have a length of 75 μm and diameters ranging from 20 to 60 nm. The CNTs have a bamboo-like structure and exhibit good crystallinity of graphite sheets. The growth rate of the CNTs was rapidly increased with adding C 2H 2. Our results demonstrate that the proposed growth method is suitable to large-scale synthesis of high-purity well-aligned CNTs on various substrates.

  12. Effect of tube diameter on the specific energy consumption of the ice making process

    International Nuclear Information System (INIS)

    Tangthieng, C.

    2011-01-01

    One of the favorite forms of ice for consuming is tube ice, which is produced by a refrigeration unit referred to as an ice making tower. In order to redesign the tower for the energy-efficiency purpose, the aim of this paper is to numerically investigate the effect of tube diameter on the ice thickness, the cooling load, and the specific energy consumption. The mathematical model of the ice formation within the tube is developed by assuming unsteady and one-dimensional heat conduction. The governing equations are composed of the wall and the ice regions with the convective boundary condition and isothermal solidification at the interface. The governing system is transformed into a dimensionless form and numerically solved by the finite difference method. The numerical results are validated by comparing the ice thickness obtained from the numerical prediction and that obtained from the field measurement, resulting in qualitative agreement. The variations of ice thickness, cooling load, and specific energy consumption with time for four different tube diameters are presented. The result shows the location of the minimum specific energy consumption as a function of time. By comparing between different tube diameters, the value of the minimum specific energy consumption of a small diameter tube is lower than that of a large diameter one. On the other hand, the behavior of the specific energy consumption of a large diameter tube indicates the existence of a low specific energy consumption period of time beyond the minimum point. Therefore, by choosing a proper tube diameter, the minimum value of the average specific energy consumption over the entire production cycle is obtained, leading to higher energy efficiency. - Research Highlights: → The result indicates the minimum specific energy consumption as a function of time. → A smaller diameter tube has a lower value of the minimum specific energy consumption, but a large one has an extended range of low specific

  13. The effects of high temperature and fiber diameter on the quasi static compressive behavior of metal fiber sintered sheets

    Energy Technology Data Exchange (ETDEWEB)

    Song, Weidong, E-mail: swdgh@bit.edu.cn [State Key Laboratory of Explosion Science and Technology, Beijing Institute of Technology, Beijing 100081 (China); Liu, Ge [State Key Laboratory of Explosion Science and Technology, Beijing Institute of Technology, Beijing 100081 (China); Wang, Jianzhong; Tang, Huiping [State Key Laboratory of Porous Metal Materials, Northwest Institute for Non-ferrous Metal Research, Xi’an 710016 (China)

    2017-04-06

    The compressive mechanical properties of the sintered sheets of continuous stainless steel fibers with different fiber diameters (8 µm, 12 µm, 28 µm) are investigated at temperatures from 298 K to 1073 K. The stress-strain curves of metal fiber sintered sheet (MFSS) are obtained by testing under uniaxial compression and 0.2% offset yield stress are determined. Inner micro-structures of the material are revealed by using scanning electron microscope (SEM) and microscopic computer tomography. The results indicates that fabrication technique and porosity are two principle factors affecting the yield strength of MFSS and the strength of MFSS is insensitive to the temperature below 873 K while softening occurs at temperature 1073 K. At relative high porosity (e.g. 77%), the material with small diameter fibers tends to have higher yield strength while at low porosity, MFSS's yield strength becomes high with the increase of the fiber diameter, which is probably attributed to the joint size, the surface appearance of fibers and prehardening generated during the manufacturing of MFSS. A simplified structure model taking joint size into consideration is established to explain the influence of the joint size on the yield strength of MFSS.

  14. High-thrust and low-power operation of a 30-cm-diameter mercury ion thruster

    Science.gov (United States)

    Beattie, J. R.; Kami, S.

    1981-01-01

    An investigation of a 30-cm-diameter mercury ion thruster designed for high-thrust and low-power operation is described. Experimental results are presented which indicate that good performance and long lifetime are achieved by using a boundary magnetic field arrangement to confine the ionizing electrons. Details of advanced ion-optics designs are discussed, and performance measurements obtained with an advanced two-grid ion-optics assembly are presented. Scaling of the state-of-the-art hollow cathode for higher emission-current capability is described, and performance and lifetime measurements are presented for the scaled cathode.

  15. Attempts to isolate a horizontal high diameter (300 mm nominal diameter) pipeline with an ice plug at minimum water flow and without water flow

    International Nuclear Information System (INIS)

    Corbescu, B.; Gyongyosi, T.; Puiu, D.; Panaitescu, V. N.

    2016-01-01

    The ice plug isolation technique used for high diameter horizontal pipes is used for repair and maintenance activities on hydraulic installations that use liquid working agents. These techniques do not require shutting down the entire plant. The ice plug development inside the pipe requires using custom specialized equipment for each individual application. This paper briefly describes the experimental technological facilities used for conducting the experiments and highlights the important aspects in an experiment conducted on a horizontal NPS 12 testing section running demineralized water followed by the result analysis and conclusions. The paper is dedicated to specialists working in research and technological engineering. (authors)

  16. The experimental study of bacterial leaching at condition of different ore's diameter

    International Nuclear Information System (INIS)

    Liu Jinhui; Li Lin; Liu Yajie

    2006-01-01

    This papper compared the effect of leaching rate of uranium and the adaptability of bacteria with the condition of different ore's diameter (2-5 mm, 5-10 mm), which use the way of inleakage-leaching. The experiment use the way that firstly acid leaching, and then 2 bacterial leaching. As a reasult that the total leaching-rate of minute diameter ore are always high than the big diameter one. But for the quantum of consumed acid its just a opposition. During bacterial leaching the adaptability of bacteria in big diameter ore are high than in the minute one. So this experiment may offer a bases for a latter industry experiment which use big diameter ore's bacterial leaching. (authors)

  17. High-speed growth of TiO2 nanotube arrays with gradient pore diameter and ultrathin tube wall under high-field anodization

    Science.gov (United States)

    Yuan, Xiaoliang; Zheng, Maojun; Ma, Li; Shen, Wenzhong

    2010-10-01

    Highly ordered TiO2 nanotubular arrays have been prepared by two-step anodization under high field. The high anodizing current densities lead to a high-speed film growth (0.40-1.00 µm min - 1), which is nearly 16 times faster than traditional fabrication of TiO2 at low field. It was found that an annealing process of Ti foil is an effective approach to get a monodisperse and double-pass TiO2 nanotubular layer with a gradient pore diameter and ultrathin tube wall (nearly 10 nm). A higher anodic voltage and longer anodization time are beneficial to the formation of ultrathin tube walls. This approach is simple and cost-effective in fabricating high-quality ordered TiO2 nanotubular arrays for practical applications.

  18. STELLAR DIAMETERS AND TEMPERATURES. III. MAIN-SEQUENCE A, F, G, AND K STARS: ADDITIONAL HIGH-PRECISION MEASUREMENTS AND EMPIRICAL RELATIONS

    International Nuclear Information System (INIS)

    Boyajian, Tabetha S.; Jones, Jeremy; White, Russel; McAlister, Harold A.; Gies, Douglas; Von Braun, Kaspar; Van Belle, Gerard; Farrington, Chris; Schaefer, Gail; Ten Brummelaar, Theo A.; Sturmann, Laszlo; Sturmann, Judit; Turner, Nils H.; Goldfinger, P. J.; Vargas, Norm; Ridgway, Stephen

    2013-01-01

    Based on CHARA Array measurements, we present the angular diameters of 23 nearby, main-sequence stars, ranging from spectral types A7 to K0, 5 of which are exoplanet host stars. We derive linear radii, effective temperatures, and absolute luminosities of the stars using Hipparcos parallaxes and measured bolometric fluxes. The new data are combined with previously published values to create an Angular Diameter Anthology of measured angular diameters to main-sequence stars (luminosity classes V and IV). This compilation consists of 125 stars with diameter uncertainties of less than 5%, ranging in spectral types from A to M. The large quantity of empirical data is used to derive color-temperature relations to an assortment of color indices in the Johnson (BVR J I J JHK), Cousins (R C I C ), Kron (R K I K ), Sloan (griz), and WISE (W 3 W 4 ) photometric systems. These relations have an average standard deviation of ∼3% and are valid for stars with spectral types A0-M4. To derive even more accurate relations for Sun-like stars, we also determined these temperature relations omitting early-type stars (T eff > 6750 K) that may have biased luminosity estimates because of rapid rotation; for this subset the dispersion is only ∼2.5%. We find effective temperatures in agreement within a couple of percent for the interferometrically characterized sample of main-sequence stars compared to those derived via the infrared flux method and spectroscopic analysis.

  19. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  20. Manufacturing of ultra-large diameter 20 MnMoNi 5 5 steel forgings for reactor pressure vessels and their properties

    International Nuclear Information System (INIS)

    Onodera, S.; Kawaguchi, S.; Tsukada, H.; Moritani, H.; Suzuki, K.; Sato, I.

    1985-01-01

    As the structural material for RPV typical of increased dimensions, as set of ultra-large diameter steel forgings for a PHWR RPV is presented as outlined below. (1) Material designation: 20 MnMoNi 5 5 (similar to SA508, Cl.3) (2) Size of the forgings: flanges, 8.440 mm OD, a weight of 238 tons for shell flange; shells and torus, 7,920 mm OD, with large height, cover dome, 6,800 mm OD in chord and 460 mm thick; blank before formed to dome is ca. 8,000 mm OD. (3) Chemical composition: particular effort was made for minimizing the tramp elements as P, S, As, Sn, Sb, Cu. (4) Manufacturing, key points: steel making - combined refining and degassing in ladle; ingot making - largest size ingots, including 570 ton and 500 ton ingots; forging - special ''outside-the-press'' forging and forming techniques; heat treatment - prevention of H 2 flaking in normalizing and tempering and handling of the extra-large forgings at water quenching. (5) Metallurgical properties: sufficiently uniform carbon distributions in the forgings; a lowest possible content of hydrogen, non-metallic inclusions and oxygen. Mechanical properties: uniformity in tensile and toughness properties; flaws - only limited number of spots of UT indications under 2 mm EFG (EFS). (orig.)

  1. An experimental study on counter current flow limitation in annular narrow gaps with large diameter

    Energy Technology Data Exchange (ETDEWEB)

    Park, Rae Joon; Jeong, Ji Whan; Lee, Sung Jin; Cho, Young Ro; Ha, Kwang Sun; Kim, Sang Baik; Kim, Hee Dong [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    The present study intends to carry out CCFL experiment with the same gap size as the CHFG facility and suggest an empirical correlation in order to provide basic information useful to development of an empirical critical-power correlation. The present facility consists of water accumulator tank, test section, DC pump, air regulator, valves and sensors. Air and water are used as working fluids. The experiments are carried out at the atmospheric pressure. Differential pressure between the gap ends, liquid and gas phase flow rates, temperature, lower plenum pressure are measured.Measured values are expressed in terms of Wallis' parameter using gap size as a characteristic length. There is a big difference between the present experimental results and the Koizumi et al.'s results, but the present experimental results are very similar to the Richter et al.'s results. The present results agree well with the Osakabe and Kawasaki's results. In comparison of present experiments with the Koizumi et al.'s experiments, gap thickness is similar, but the diameter of the present is bigger than that of Koizumi et al.'s experiments. In comparison of present experiments with the Richter et al.'s experiments, diameter is similar, but the gap thickness of the present is smaller than that of Richter et al.'s experiments. It is judged from these results that correlation development on CCFL to consider gap thickness is reasonable at similar condition of diameter.The developed correlation will be used to develop the CHFG model. 36 refs., 26 figs., 7 tabs. (Author)

  2. Measurements of the diameter of the supernova SN 1987A

    International Nuclear Information System (INIS)

    Karovska, M.; Nisenson, P.; Standley, C.; Heathcote, S.R.

    1991-01-01

    Speckle interferometric measurements of the angular diameter of SN 1987A in the Large Magellanic Cloud, obtained at 664 days after the outburst are presented. Diameters were estimated with milliarcsec precision at 657 nm and 550 nm by fitting model visibility functions to the data corresponding to different intensity distributions for the supernova disk. Measurements made assuming a uniform intensity distribution were compared to the uniform disk measurements obtained from 30 days after the explosion. Diameter measurements obtained near the center of the H-alpha line are consistent with homologous expansion of the supernova shell with a mean velocity of 2850 km/s. The linear least-squares fit to the measurements obtained at other wavelengths from 260 days after the explosion yielded a somewhat lower mean expansion velocity. 8 refs

  3. Evaluation of stresses in large diameter, thin walled piping at support locations

    International Nuclear Information System (INIS)

    Bryan, B.J.; Flanders, H.E. Jr.; Rawls, G.B. Jr.

    1992-01-01

    The highest stresses in many thin walled piping systems are the local stresses at the pipe supports. These secondary stresses are caused by saddles or other structural discontinuities that restrain pipe ovalization. A static analysis of a thin walled pipe supported on structural steel saddle under dead weight loading is presented. The finite element analysis is performed using a shell model with distributed gravity and hydrostatic pressure loading. Parametric studies on global and local stress are performed to determine the effect of the pipe diameter to thickness ratio. Two aspects of the saddle design are also investigated: the effect of saddle width, and the effect of saddle wrap angle. Additionally, the computed stresses are compared to closed form solutions

  4. Thermal-Infrared Surveys of Near-Earth Object Diameters and Albedos with Spitzer and IRTF/MIRSI

    Science.gov (United States)

    Mommert, Michael; Trilling, David; Hora, Joseph L.; Chesley, Steven; Emery, Josh; Fazio, Giovanni; Harris, Alan W.; Moskovitz, Nick; Mueller, Michael; Smith, Howard

    2015-08-01

    More than 12000 Near-Earth Objects (NEOs) have been discovered over the past few decades and current discovery surveys find on average 4 new NEOs every night. In comparison to asteroid discovery, the physical characterization of NEOs lags far behind: measured diameters and albedos exist only for roughly 10% of all known NEOs. We describe a current and a future observing program that provide diameter and albedo measurements of a large number of NEOs.In our Spitzer Space Telescope Exploration Science program 'NEOSurvey', we are performing a fast and efficient flux-limited survey in which we measure the diameters and albedos of ~600 NEOs in a total of 710 hrs of observing time. We measure the thermal emission of our targets at 4.5 micron and combine these measurements with optical data in a thermal model. Our diameters and albedos come with highly realistic uncertainties that account for a wide range of potential asteroid properties. Our primary goal is to create a large and uniform catalog of NEO properties, including diameters, albedos, and flux density data. This catalog is publicly accessible and provides the latest results usually within 2 weeks after the observation.Starting in 2016, we will also make use of the refurbished and recommissioned MIRSI mid-infrared imaging camera on NASA's InfraRed Telescope Facility (IRTF) to derive the diameters and albedos of up to 750 NEOs over a period of 3 yrs. MIRSI will be equipped with an optical camera that will allow for simultaneous optical imaging, which will improve our thermal modeling results. With MIRSI, we will focus on newly discovered NEOs that are close to Earth and hence relatively bright.The results from both programs, together with already exisiting diameter and albedo results from the literature, will form the largest database of NEO physical properties available to date. With this data set, we will be able to refine the size distribution of small NEOs and the corresponding impact frequency, and compare the

  5. Pile load test on large diameter steel pipe piles in Timan-Pechora, Russia

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, S. [Golder Associates Inc., Houston, TX (United States); Tart, B. [Golder Associates Inc., Anchorage, AK (United States); Swartz, R. [Paragon Engineering Services Inc., Houston, TX (United States)

    1994-12-31

    Pile load testing conducted in May and June of 1993 at the Polar Lights Ardalin project in Arkangelsk province, Russia, was documented. Pile load testing was conducted to determine the ultimate and allowable pile loads for varying pile lengths and ground temperature conditions and to provide creep test data for deformation under constant load. The piles consisted of 20 inch diameter steel pipe piles driven open ended through prebored holes into the permafrost soils. Ultimate pile capacities, adfreeze bond, and creep properties observed were discussed. 10 figs., 4 tabs.

  6. Experimental and Numerical Investigation of a 60cm Diameter Bladeless Fan

    OpenAIRE

    mohammad jafari; Hossein Afshin; Bijan Farhanieh; Hamidreza bozorgasareh

    2016-01-01

    Bladeless fan is a novel type of fan with an unusual geometry and unique characteristics. This type of fan has been recently developed for domestic applications in sizes typically up to 30cm diameter. In the present study, a Bladeless fan with a diameter of 60cm was designed and constructed, in order to investigate feasibility of its usage in various industries with large dimensions. Firstly, flow field passed through this fan was studied by 3D modeling. Aerodynamic and aeroacoust...

  7. Structural concepts for very large (400-meter-diameter) solar concentrators

    Science.gov (United States)

    Mikulas, Martin M., Jr.; Hedgepeth, John M.

    1989-01-01

    A general discussion of various types of large space structures is presented. A brief overview of the history of space structures is presented to provide insight into the current state-of-the art. Finally, the results of a structural study to assess the viability of very large solar concentrators are presented. These results include weight, stiffness, part count, and in-space construction time.

  8. Biodegradable Magnetic Silica@Iron Oxide Nanovectors with Ultra-Large Mesopores for High Protein Loading, Magnetothermal Release, and Delivery

    KAUST Repository

    Omar, Haneen

    2016-11-29

    The delivery of large cargos of diameter above 15 nm for biomedical applications has proved challenging since it requires biocompatible, stably-loaded, and biodegradable nanomaterials. In this study, we describe the design of biodegradable silica-iron oxide hybrid nanovectors with large mesopores for large protein delivery in cancer cells. The mesopores of the nanomaterials spanned from 20 to 60 nm in diameter and post-functionalization allowed the electrostatic immobilization of large proteins (e.g. mTFP-Ferritin, ~ 534 kDa). Half of the content of the nanovectors was based with iron oxide nanophases which allowed the rapid biodegradation of the carrier in fetal bovine serum and a magnetic responsiveness. The nanovectors released large protein cargos in aqueous solution under acidic pH or magnetic stimuli. The delivery of large proteins was then autonomously achieved in cancer cells via the silica-iron oxide nanovectors, which is thus a promising for biomedical applications.

  9. STELLAR DIAMETERS AND TEMPERATURES. III. MAIN-SEQUENCE A, F, G, AND K STARS: ADDITIONAL HIGH-PRECISION MEASUREMENTS AND EMPIRICAL RELATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Boyajian, Tabetha S.; Jones, Jeremy; White, Russel; McAlister, Harold A.; Gies, Douglas [Center for High Angular Resolution Astronomy and Department of Physics and Astronomy, Georgia State University, P.O. Box 4106, Atlanta, GA 30302-4106 (United States); Von Braun, Kaspar [NASA Exoplanet Science Institute, California Institute of Technology, MC 100-22, Pasadena, CA 91125 (United States); Van Belle, Gerard [Lowell Observatory, Flagstaff, AZ 86001 (United States); Farrington, Chris; Schaefer, Gail; Ten Brummelaar, Theo A.; Sturmann, Laszlo; Sturmann, Judit; Turner, Nils H.; Goldfinger, P. J.; Vargas, Norm [CHARA Array, Mount Wilson Observatory, Mount Wilson, CA 91023 (United States); Ridgway, Stephen [National Optical Astronomy Observatory, P.O. Box 26732, Tucson, AZ 85726-6732 (United States)

    2013-07-01

    Based on CHARA Array measurements, we present the angular diameters of 23 nearby, main-sequence stars, ranging from spectral types A7 to K0, 5 of which are exoplanet host stars. We derive linear radii, effective temperatures, and absolute luminosities of the stars using Hipparcos parallaxes and measured bolometric fluxes. The new data are combined with previously published values to create an Angular Diameter Anthology of measured angular diameters to main-sequence stars (luminosity classes V and IV). This compilation consists of 125 stars with diameter uncertainties of less than 5%, ranging in spectral types from A to M. The large quantity of empirical data is used to derive color-temperature relations to an assortment of color indices in the Johnson (BVR{sub J} I{sub J} JHK), Cousins (R{sub C} I{sub C}), Kron (R{sub K} I{sub K}), Sloan (griz), and WISE (W{sub 3} W{sub 4}) photometric systems. These relations have an average standard deviation of {approx}3% and are valid for stars with spectral types A0-M4. To derive even more accurate relations for Sun-like stars, we also determined these temperature relations omitting early-type stars (T{sub eff} > 6750 K) that may have biased luminosity estimates because of rapid rotation; for this subset the dispersion is only {approx}2.5%. We find effective temperatures in agreement within a couple of percent for the interferometrically characterized sample of main-sequence stars compared to those derived via the infrared flux method and spectroscopic analysis.

  10. Novel strategy for diameter-selective separation and functionalization of single-wall carbon nanotubes.

    Science.gov (United States)

    Tromp, R M; Afzali, A; Freitag, M; Mitzi, D B; Chen, Zh

    2008-02-01

    The problem of separating single-wall carbon nanotubes (CNTs) by diameter and/or chirality is one of the greatest impediments toward the widespread application of these promising materials in nanoelectronics. In this paper, we describe a novel physical-chemical method for diameter-selective CNT separation that is both simple and effective and that allows up-scaling to large volumes at modest cost. Separation is based on size-selective noncovalent matching of an appropriate anchor molecule to the wall of the CNT, enabling suspension of the CNTs in solvents in which they would otherwise not be soluble. We demonstrate size-selective separation in the 1-2 nm diameter range using easily synthesized oligo-acene adducts as a diameter-selective molecular anchor. CNT field effect transistors fabricated from diameter-selected CNTs show markedly improved electrical properties as compared to nonselected CNTs.

  11. Bubble behaviour and mean diameter in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, O.; Shoukri, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1995-09-01

    Bubble behaviour and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. A high speed video system was used to visualize the subcooled flow boiling phenomenon. The high speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapour generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux and mass flux was obtained.

  12. Experimental analysis of heat transfer between a heated wire and a rarefied gas in an annular gap with high diameter ratio

    International Nuclear Information System (INIS)

    Chalabi, H; Lorenzini, M; Morini, G L; Buchina, O; Valougeorgis, D; Saraceno, L

    2012-01-01

    In this paper a first experimental attempt is performed to measure heat conduction through rarefied air at rest contained between two concentric cylinders. The heat transfer between a heated platinum wire having a diameter (d) of 0.15 mm, disposed along the axis of a cylindrical shell in stainless steel having an inner diameter (D) of 100 mm, and a surrounded rarefied gas has been studied experimentally and numerically. The ratio between the outer and inner diameter of the annular region filled by the gas is large (D/d=667). In the annular region filled with air the pressure was varied by using a vacuum pump from atmospheric value down to 10 −3 mbar. Temperature differences between the wire and the external stainless steel wall in the range 50-125 K were imposed and the heat power transferred from the wire to the surround was measured as a function of the gas pressure starting from air at atmospheric conditions down to 10 −3 mbar. The experimental results obtained in these tests were compared with the numerical results obtained by using the linear and nonlinear Shakhov kinetic models.

  13. Large diameter boreholes (LDB) for low and intermediate radioactive waste storage/disposal in clay deposits

    International Nuclear Information System (INIS)

    Tkachenko, A.V.; Litinsky, Y.V.; Guskov, A.V.

    2012-01-01

    shortage of free area after 30-40 years of operation or because of ecological and radiological safety reasons. To minimize these effects and increase ecological safety of near-surface RAW storage facilities as well as to use operating territory in more effective manner the new type of long term storage/disposal facility has been developed on the basis of Large Diameter Borehole (LDB), drilled in clayey sediments. In the case of LDB applications for LILW storage the waste are removed from the scope of human activity into a stable geological medium. Wastes are placed below the frost zone where damage to engineered barriers due to climatic factors is practically impossible. Construction of the repository by means of drilling prevents large disturbances of the host rock, as happens during excavation work for trenches. When using an LDB-type repositories, the usage factor (ratio of repository surface area, protected with natural barrier, to total repository surface area) of the geological barrier (host rocks) is about 1, as almost all the surface of the repository is protected with not disturbed host rock. This helps to draw the conclusion that, even in the case of total destruction of all engineered barriers, which is very unlikely, radionuclides will still be constrained in a small volume of the host rock and their release to the human activity sphere is virtually impossible. Two LDB-type repositories (LDB-1 and LDB-2) with the internal diameter of 1.5 m and the depth near 40 m have been constructed at the site of SUE MosSIA 'Radon'. In October 2003 LDB-2 for the first time has been loaded with low and intermediate level radioactive waste, conditioned in 36 standard steel drums. In May 2006 LDB-1 has been loaded with 90 similar drums. Later on both Large Diameter Boreholes were licensed for RAW storage. Since 2003 a complex of manual observations within the repository, in engineered barriers and in near field was carried out to assess the tightness of construction, its

  14. Experiments on hydraulically-compensated Compressed Air Energy Storage (CAES) system using large-diameter vertical pipe two-phase flow test facility: test facility and test procedure

    International Nuclear Information System (INIS)

    Ohtsu, Iwao; Murata, Hideo; Kukita, Yutaka; Kumamaru, Hiroshige.

    1996-07-01

    JAERI, the University of Tokyo, the Central Research Institute of Electric Power Industry and Shimizu Corporation jointing performed and experimental study on two-phase flow in the hydraulically-compensated Compressed Air Energy Storage (CAES) system with a large-diameter vertical pipe two-phase flow test facility from 1993 to 1995. A hydraulically-compensated CAES system is a proposed, conceptual energy storage system where energy is stored in the form of compressed air in an underground cavern which is sealed by a deep (several hundred meters) water shaft. The shaft water head maintains a constant pressure in the cavern, of several mega Pascals, even during loading or unloading of the cavern with air. The dissolved air in the water, however, may create voids in the shaft when the water rises through the shaft during the loading, being forced by the air flow into the cavern. The voids may reduce the effective head of the shaft, and thus the seal may fail, if significant bubbling should occur in the shaft. This bubbling phenomenon (termed 'Champaign effect') and potential failure of the water seal ('blowout') are simulated in a scaled-height, scaled-diameter facility. Carbon dioxide is used to simulate high solubility of air in the full-height, full-pressure system. This report describes the expected and potential two-phase flow phenomena in a hydraulically-compensated CAES system, the test facility and the test procedure, a method to estimate quantities which are not directly measured by using measured quantities and hydrodynamic basic equations, and desirable additional instrumentation. (author)

  15. Failure Diameter of PBX 9502: Simulations with the SURFplus model

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-03

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

  16. METHODS OF CONTROLLING THE AVERAGE DIAMETER OF THE THREAD WITH ASYMMETRICAL PROFILE

    Directory of Open Access Journals (Sweden)

    L. M. Aliomarov

    2015-01-01

    Full Text Available To handle the threaded holes in hard materials made of marine machinery, operating at high temperatures, heavy loads and in aggressive environments, the authors have developed the combined tool core drill -tap with a special cutting scheme, which has an asymmetric thread profile on the tap part. In order to control the average diameter of the thread of tap part of the combined tool was used the method three wires, which allows to make continuous measurement of the average diameter of the thread along the entire profile. Deviation from the average diameter from the sample is registered by inductive sensor and is recorded by the recorder. In the work are developed and presented control schemes of the average diameter of the threads with a symmetrical and asymmetrical profile. On the basis of these schemes are derived formulas for calculating the theoretical option to set the wires in the thread profile in the process of measuring the average diameter. Conducted complex research and the introduction of the combined instrument core drill-tap in the production of products of marine engineering, shipbuilding, ship repair power plants made of hard materials showed a high efficiency of the proposed technology for the processing of high-quality small-diameter threaded holes that meet modern requirements.

  17. Measurement of nucleation site density, bubble departure diameter and frequency in pool boiling of water using high-speed infrared and optical cameras

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig; Buongiorno, Jacopo; Hu, Lin-wen; McKrell, Thomas [Massachusetts Institute of Technology, Cambridge, MA (United States)], e-mail: jacopo@mit.edu

    2009-07-01

    A high-speed video and IR thermometry based technique has been used to obtain time and space resolved information on bubble nucleation and boiling heat transfer. This approach provides a fundamental and systematic method for investigating nucleate boiling in a very detailed fashion. Data on bubble departure diameter and frequency, growth and wait times, and nucleation site density are measured with relative ease. The data have been compared to the traditional decades-old and poorly-validated nucleate-boiling models and correlations. The agreement between the data and the models is relatively good. This study also shows that new insights into boiling heat transfer mechanisms can be obtained with the present technique. For example, our data and analysis suggest that a large contribution to bubble growth comes from heat transfer through the superheated liquid layer in addition to micro layer evaporation. (author)

  18. Measurement of nucleation site density, bubble departure diameter and frequency in pool boiling of water using high-speed infrared and optical cameras

    International Nuclear Information System (INIS)

    Gerardi, Craig; Buongiorno, Jacopo; Hu, Lin-wen; McKrell, Thomas

    2009-01-01

    A high-speed video and IR thermometry based technique has been used to obtain time and space resolved information on bubble nucleation and boiling heat transfer. This approach provides a fundamental and systematic method for investigating nucleate boiling in a very detailed fashion. Data on bubble departure diameter and frequency, growth and wait times, and nucleation site density are measured with relative ease. The data have been compared to the traditional decades-old and poorly-validated nucleate-boiling models and correlations. The agreement between the data and the models is relatively good. This study also shows that new insights into boiling heat transfer mechanisms can be obtained with the present technique. For example, our data and analysis suggest that a large contribution to bubble growth comes from heat transfer through the superheated liquid layer in addition to micro layer evaporation. (author)

  19. A multifunctional role of trialkylbenzenes for the preparation of aqueous colloidal mesostructured/mesoporous silica nanoparticles with controlled pore size, particle diameter, and morphology

    Science.gov (United States)

    Yamada, Hironori; Ujiie, Hiroto; Urata, Chihiro; Yamamoto, Eisuke; Yamauchi, Yusuke; Kuroda, Kazuyuki

    2015-11-01

    Both the pore size and particle diameter of aqueous colloidal mesostructured/mesoporous silica nanoparticles (CMSS/CMPS) derived from tetrapropoxysilane were effectively and easily controlled by the addition of trialkylbenzenes (TAB). Aqueous highly dispersed CMPS with large pores were successfully obtained through removal of surfactants and TAB by a dialysis process. The pore size (from 4 nm to 8 nm) and particle diameter (from 50 nm to 380 nm) were more effectively enlarged by the addition of 1,3,5-triisopropylbenzene (TIPB) than 1,3,5-trimethylbenzene (TMB), and the enlargement did not cause the variation of the mesostructure and particle morphology. The larger molecular size and higher hydrophobicity of TIPB than TMB induce the incorporation of TIPB into micelles without the structural change. When TMB was used as TAB, the pore size of CMSS was also enlarged while the mesostructure and particle morphology were varied. Interestingly, when tetramethoxysilane and TIPB were used, CMSS with a very small particle diameter (20 nm) with concave surfaces and large mesopores were obtained, which may strongly be related to the initial nucleation of CMSS. A judicious choice of TAB and Si sources is quite important to control the mesostructure, size of mesopores, particle diameter, and morphology.Both the pore size and particle diameter of aqueous colloidal mesostructured/mesoporous silica nanoparticles (CMSS/CMPS) derived from tetrapropoxysilane were effectively and easily controlled by the addition of trialkylbenzenes (TAB). Aqueous highly dispersed CMPS with large pores were successfully obtained through removal of surfactants and TAB by a dialysis process. The pore size (from 4 nm to 8 nm) and particle diameter (from 50 nm to 380 nm) were more effectively enlarged by the addition of 1,3,5-triisopropylbenzene (TIPB) than 1,3,5-trimethylbenzene (TMB), and the enlargement did not cause the variation of the mesostructure and particle morphology. The larger molecular size

  20. On-fiber 3D printing of photonic crystal fiber tapers for mode field diameter conversion

    KAUST Repository

    Bertoncini, Andrea; Rajamanickam, Vijayakumar Palanisamy; Liberale, Carlo

    2017-01-01

    The large mismatch between the Mode Field Diameter (MFD) of conventional single-mode fibers (SMFs) and the MFD of highly nonlinear Photonic Crystal Fibers (PCFs), that can be down to 1.5 μm, or Large Mode Area PCF, that can be up to 25 μm, would require a substantial fiber mode size rescaling in order to allow an efficient direct coupling between PCFs and SMFs. Over the years different solutions have been proposed, as fiber splicing of SMF to PCF. However these procedures are not straightforward, as they involve developing special splicing recipes, and can affect PCF optical properties at the splice interface [1].

  1. On-fiber 3D printing of photonic crystal fiber tapers for mode field diameter conversion

    KAUST Repository

    Bertoncini, Andrea

    2017-11-02

    The large mismatch between the Mode Field Diameter (MFD) of conventional single-mode fibers (SMFs) and the MFD of highly nonlinear Photonic Crystal Fibers (PCFs), that can be down to 1.5 μm, or Large Mode Area PCF, that can be up to 25 μm, would require a substantial fiber mode size rescaling in order to allow an efficient direct coupling between PCFs and SMFs. Over the years different solutions have been proposed, as fiber splicing of SMF to PCF. However these procedures are not straightforward, as they involve developing special splicing recipes, and can affect PCF optical properties at the splice interface [1].

  2. High-speed growth of TiO{sub 2} nanotube arrays with gradient pore diameter and ultrathin tube wall under high-field anodization

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Xiaoliang; Zheng Maojun; Shen Wenzhong [Key Laboratory of Artificial Structures and Quantum Control, Ministry of Education, Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China); Ma Li, E-mail: mjzheng@sjtu.edu.cn [School of Chemistry and Chemical Technology, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2010-10-08

    Highly ordered TiO{sub 2} nanotubular arrays have been prepared by two-step anodization under high field. The high anodizing current densities lead to a high-speed film growth (0.40-1.00 {mu}m min{sup -1}), which is nearly 16 times faster than traditional fabrication of TiO{sub 2} at low field. It was found that an annealing process of Ti foil is an effective approach to get a monodisperse and double-pass TiO{sub 2} nanotubular layer with a gradient pore diameter and ultrathin tube wall (nearly 10 nm). A higher anodic voltage and longer anodization time are beneficial to the formation of ultrathin tube walls. This approach is simple and cost-effective in fabricating high-quality ordered TiO{sub 2} nanotubular arrays for practical applications.

  3. Fabrication of 0.5-inch diameter FBR mixed oxide fuel pellets

    International Nuclear Information System (INIS)

    Rasmussen, D.E.; Benecke, M.W.; McCord, R.B.

    1979-01-01

    Large diameter (0.535 inch) mixed oxide fuel pellets for Fast Breeder Reactor application were successfully fabricated by the cold-press-and-sinter technique. Enriched UO 2 , PuO 2 -UO 2 , and PuO 2 -ThO 2 compositions were fabricated into nominally 90% theoretical density pellets for the UO 2 and PuO 2 -UO 2 compositions, and 88% and 93% T.D. for the PuO 2 -ThO 2 compositions. Some processing adjustments were required to achieve satisfactory pellet quality and density. Furnace heating rate was reduced from 200 to 50 0 C/h for the organic binder burnout cycle for the large, 0.535-inch diameter pellets to eliminate pellet cracking during sintering. Additional preslugging steps and die wall lubrication during pressing were used to eliminate pressing cracks in the PuO 2 -ThO 2 pellets

  4. Effect of diameter and chirality on the structure and electronic properties of BC2N nanotubes

    International Nuclear Information System (INIS)

    Akhavan, Mojdeh; Jalili, Seifollah; Schofield, Jeremy

    2015-01-01

    Highlights: • BC 2 N nanotubes with different diameters and four chirality types are studied. • Two lowest-diameter zigzag BC 2 N tubes are metallic and others are semiconducting. • Band gap of zigzag tubes is more sensitive to diameter compared to armchair tubes. • Even–odd oscillation is observed for the band gap of one kind of zigzag tubes. • The energy and band gap for large-diameter tubes converge to BC 2 N sheet values. - Abstract: Density functional theory calculations are used to investigate a series of BC 2 N nanotubes with a wide range of diameters. Two types of zigzag and two types of armchair nanotubes are studied to survey the effect of diameter and chirality on energetics and electronic properties of nanotubes. Two nanotubes are found to be metallic and others show semiconducting behavior. The diameter is shown to have a greater impact on the band gap of zigzag nanotubes than those of armchair tubes. (n, 0) zigzag nanotubes show an even–odd band gap oscillation, which can be explained by the electron density distribution of the lowest unoccupied crystalline orbital. The stability of the nanotubes is also assessed using strain energies and it is shown that the strain energy does not depend on nanotube type and chirality. In the limit of large diameters, the geometry and band gap of all nanotubes converge to BC 2 N sheet data

  5. High spatial resolution gamma imaging detector based on a 5 inch diameter R3292 Hamamatsu PSPMT

    International Nuclear Information System (INIS)

    Wojcik, R.; Majewski, S.; Kross, B.; Weisenberger, A.G.; Steinbach, D.

    1998-01-01

    High resolution imaging gamma-ray detectors were developed using Hamamatsu's 5 inch diameter R3292 position sensitive PMT (PSPMT) and a variety of crystal scintillator arrays. Special readout techniques were used to maximize the active imaging area while reducing the number of readout channels. Spatial resolutions approaching 1 mm were obtained in a broad energy range from 20 to 511 keV. Results are also presented of coupling the scintillator arrays to the PMT via imaging light guides consisting of acrylic optical fibers

  6. Numerical simulation of the processes of small-diameter high-current electron beam shaping and injection

    CERN Document Server

    Gordeev, V S; Myskov, G A

    2001-01-01

    With the aid of BEAM 25 program there was carried out the numerical simulation of the non-stationary process of shaping a small-diameter (<= 20mm) high-current hollow electron beam in a diode with magnetic insulation,as well as of the process of beam injection into the accelerating LIA track. The diode configuration for the purpose of eliminating the leakage of electron flux to the anode surface was update. Presented are the results of calculation of the injected beam characteristics (amplitude-time parameters of a current pulse, space-angle distributions of electrons etc.) depending on diode geometric parameters.

  7. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  8. Large diameter lithium compensated silicon detectors for the NASA Advanced Composition Explorer (ACE) mission

    International Nuclear Information System (INIS)

    Allbritton, G.L.; Andersen, H.; Barnes, A.

    1996-01-01

    Fabrication of the 100 mm diameter, 3 mm thick lithium-compensated silicon, Si(Li), detectors for the Cosmic Ray Isotope Spectrometer (CRIS) instrument on board the ACE satellite required development of new float-zone silicon growing techniques, new Si(Li) fabrication procedures, and new particle beam testing sequences. These developments are discussed and results are presented that illustrate the advances made in realizing these CRIS Si(Li) detectors, which, when operational in the CRIS detector telescopes, will usher in a new generation of cosmic-ray isotope spectrometers

  9. High-uniformity centimeter-wide Si etching method for MEMS devices with large opening elements

    Science.gov (United States)

    Okamoto, Yuki; Tohyama, Yukiya; Inagaki, Shunsuke; Takiguchi, Mikio; Ono, Tomoki; Lebrasseur, Eric; Mita, Yoshio

    2018-04-01

    We propose a compensated mesh pattern filling method to achieve highly uniform wafer depth etching (over hundreds of microns) with a large-area opening (over centimeter). The mesh opening diameter is gradually changed between the center and the edge of a large etching area. Using such a design, the etching depth distribution depending on sidewall distance (known as the local loading effect) inversely compensates for the over-centimeter-scale etching depth distribution, known as the global or within-die(chip)-scale loading effect. Only a single DRIE with test structure patterns provides a micro-electromechanical systems (MEMS) designer with the etched depth dependence on the mesh opening size as well as on the distance from the chip edge, and the designer only has to set the opening size so as to obtain a uniform etching depth over the entire chip. This method is useful when process optimization cannot be performed, such as in the cases of using standard conditions for a foundry service and of short turn-around-time prototyping. To demonstrate, a large MEMS mirror that needed over 1 cm2 of backside etching was successfully fabricated using as-is-provided DRIE conditions.

  10. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  11. Measurement and modeling of diameter distributions of particulate matter in terrestrial solutions

    Science.gov (United States)

    Levia, Delphis F.; Michalzik, Beate; Bischoff, Sebastian; NäThe, Kerstin; Legates, David R.; Gruselle, Marie-Cecile; Richter, Susanne

    2013-04-01

    Particulate matter (PM) plays an important role in biogeosciences, affecting biosphere-atmosphere interactions and ecosystem health. This is the first known study to quantify and model PM diameter distributions of bulk precipitation, throughfall, stemflow, and organic layer (Oa) solution. Solutions were collected from a European beech (Fagus sylvatica L.) forest during leafed and leafless periods. Following scanning electron microscopy and image analysis, PM distributions were quantified and then modeled with the Box-Cox transformation. Based on an analysis of 43,278 individual particulates, median PM diameter of all solutions was around 3.0 µm. All PM diameter frequency distributions were skewed significantly to the right. Optimal power transformations of PM diameter distributions were between -1.00 and -1.56. The utility of this model reconstruction would be that large samples having a similar probability density function can be developed for similar forests. Further work on the shape and chemical composition of particulates is warranted.

  12. Public issues associated with planning a large diameter pipeline in a multi-use urban corridor

    Energy Technology Data Exchange (ETDEWEB)

    Buszynski, M. [SENES Consultants Ltd., Richmond Hill, ON (Canada)

    2004-07-01

    The demand for natural gas in a downtown area of Toronto is expected to increase significantly due to the proposed construction of two new generation stations. However, there are few opportunities to locate the pipelines in large urban centers because of the lack of foresight by municipalities and others in preserving corridors for utilities. Enbridge Gas conducted a system planning study to determine the best methods for overcoming public issues that were encountered while planning the route for a NPS 36 inch diameter natural gas pipeline in this urban region. In Ontario, distribution pipelines are regulated by the Ontario Energy Board, whose environmental guidelines for the location, construction and operation of hydrocarbon pipelines require the identification of indirectly affected landowners and detailed analysis of public issues and how they can be resolved. Issues include noise, vibration, dust and traffic. Secondary use of the electric transmission rights-of-way resulted in the identification of several other issues, including aesthetics of the right-of-way and loss of privacy for adjacent residential properties. It was determined that the optimal solution was to parallel a section of existing NPS 30 pipeline running in a north-south right-of-way located east of the Don Valley Parkway. The techniques used to address public issues identified 180 directly affected and 3,200 indirectly affected landowners. The Enbridge study revealed that it is possible to plan a right-of-way through an urban corridor in a manner that is compatible with existing development and that satisfies the general public. 6 figs.

  13. Bloch-Wave Engineered Submicron Diameter Micropillars with Quality Factors Exceeding 10,000

    DEFF Research Database (Denmark)

    Hofling, S.; Lermer, M.; Gregersen, Niels

    2011-01-01

    Adiabatic design submicron diameter quantum-dot micropillars have been designed and implemented for cavity quantum electrodynamics experiments. Ultra-high experimental quality factors (>10,000) are obtained for submicron diameters and strong light-matter interaction is observed....

  14. On the aspiration characteristics of large-diameter, thin-walled aerosol sampling probes at yaw orientations with respect to the wind

    International Nuclear Information System (INIS)

    Vincent, J.H.; Mark, D.; Smith, T.A.; Stevens, D.C.; Marshall, M.

    1986-01-01

    Experiments were carried out in a large wind tunnel to investigate the aspiration efficiencies of thin-walled aerosol sampling probes of large diameter (up to 50 mm) at orientations with respect to the wind direction ranging from 0 to 180 degrees. Sampling conditions ranged from sub-to super-isokinetic. The experiments employed test dusts of close-graded fused alumina and were conducted under conditions of controlled freestream turbulence. For orientations up to and including 90 degrees, the results were qualitatively and quantitatively consistent with a new physical model which takes account of the fact that the sampled air not only diverges or converges (depending on the relationship between wind speed and sampling velocity) but also turns to pass through the plane of the sampling orifice. The previously published results of Durham and Lundgren (1980) and Davies and Subari (1982) for smaller probes were also in good agreement with the new model. The model breaks down, however, for orientations greater than 90 degrees due to the increasing effect of particle impaction onto the blunt leading edge of the probe body. For the probe facing directly away from the wind (180 degree orientation), aspiration efficiency is dominated almost entirely by this effect. (author)

  15. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  16. Ultra-large size austenitic stainless steel forgings for fast breeder reactor 'Monju'

    International Nuclear Information System (INIS)

    Tsukada, Hisashi; Suzuki, Komei; Sato, Ikuo; Miura, Ritsu.

    1988-01-01

    The large SUS 304 austenitic stainless steel forgings for the reactor vessel of the prototype FBR 'Monju' of 280 MWe output were successfully manufactured. The reactor vessel contains the heart of the reactor and sodium coolant at 530 deg C, and its inside diameter is about 7 m, and height is about 18 m. It is composed of 12 large forgings, that is, very thick flanges and shalls made by ring forging and an end plate made by disk forging and hot forming, using a special press machine. The manufacture of these large forgings utilized the results of the basic test on the material properties in high temperature environment and the effect that the manufacturing factors exert on the material properties and the results of the development of manufacturing techniques for superlarge forgings. The problems were the manufacturing techniques for the large ingots of 250 t class of high purity, the hot working techniques for stainless steel of fine grain size, the forging techniques for superlarge rings and disks, and the machining techniques of high precision for particularly large diameter, thin wall rings. The manufacture of these large stainless steel forgings is reported. (Kako, I.)

  17. Reference interval for the disc-macula distance to disc diameter ratio in a large population of healthy Japanese adults: A prospective, observational study.

    Science.gov (United States)

    Sato, Ken-Ichi

    2017-04-01

    This study presents the calculated reference interval for the disc-to-macula distance to disc diameter ratio (DM:DD) based on a large population of healthy Japanese adults.A total of 308 consecutive, healthy Japanese adults were examined in this prospective observational study. Eighteen subjects were also excluded because of poor quality of the fundus photograph of one or both eyes; 290 (161 men and 129 women) were included in this study. For each subject, a color fundus photograph of one eye, either the right or left, was randomly selected and used for analysis. On the photograph, the distances between the fovea and the nearest temporal margin of the optic disc (Dft), and the two kinds of disc diameters (D1 and D2), which bisected at right angles and one of which was directed to the fovea (D1), were measured. DM:DD was estimated using the formula: (2Dft + D1)/(D1 + D2).The mean ± standard deviation of DM:DD was 2.91 ± 0.49 for men and 2.96 ± 0.54 for women; there was no sex difference (P = .78, Mann-Whitney U test). Also, almost no relationship was found between DM:DD and age (ρ = -.12, P = .04, Spearman's rank correlation coefficient). The data did not fit a normal distribution (P < .001, Kolmogorov-Smirnov test). The estimated reference interval for DM:DD corresponding to the 2.5th and 97.5th percentiles was 2.12 to 4.18.Using a nonparametric approach, the reference interval for DM:DD of a large population of healthy Japanese adults was calculated to be 2.12 to 4.18, regardless of age or sex.

  18. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  19. Diameter Effect of Silver Nanorod Arrays to Surface-enhanced Raman Scattering

    International Nuclear Information System (INIS)

    Gu, Geun Hoi; Kim, Min Young; Yoon, Hyeok Jin; Suh, Jung Sang

    2014-01-01

    The effect the diameter of silver nanorod arrays whose distance between the nanorods was uniform at 65 nm have on Surface-enhanced Raman Scattering (SERS) has been studied by varying the diameter from 28 to 51 nm. Nanorod length was fixed at approximately 62 nm, which is the optimum length for SERS by excitation with a 632.8 nm laser line. The transverse and longitudinal modes of the surface plasmon of these silver nanorods were near 400 and 630 nm, respectively. The extinction of the longitudinal mode increased with increasing nanorod diameter, while the transverse mode did not change significantly. High-quality SERS spectra of p-aminothiophenol and benzenethiol adsorbed on the tips of the silver nanorods were observed by excitation with a 632.8 nm laser line. The SERS enhancement increased with increasing nanorod diameter. We concluded that the SERS enhancement increases when the diameter of silver nanorods is increased mainly by increasing the excitation efficiency of the longitudinal mode. The enhancement factor for the silver nanorods with a 51 nm diameter was approximately 2 Χ 10 7

  20. Engineering of an E. coli outer membrane protein FhuA with increased channel diameter

    Directory of Open Access Journals (Sweden)

    Dworeck Tamara

    2011-08-01

    Full Text Available Abstract Background Channel proteins like FhuA can be an alternative to artificial chemically synthesized nanopores. To reach such goals, channel proteins must be flexible enough to be modified in their geometry, i.e. length and diameter. As continuation of a previous study in which we addressed the lengthening of the channel, here we report the increasing of the channel diameter by genetic engineering. Results The FhuA Δ1-159 diameter increase has been obtained by doubling the amino acid sequence of the first two N-terminal β-strands, resulting in variant FhuA Δ1-159 Exp. The total number of β-strands increased from 22 to 24 and the channel surface area is expected to increase by ~16%. The secondary structure analysis by circular dichroism (CD spectroscopy shows a high β-sheet content, suggesting the correct folding of FhuA Δ1-159 Exp. To further prove the FhuA Δ1-159 Exp channel functionality, kinetic measurement using the HRP-TMB assay (HRP = Horse Radish Peroxidase, TMB = 3,3',5,5'-tetramethylbenzidine were conducted. The results indicated a 17% faster diffusion kinetic for FhuA Δ1-159 Exp as compared to FhuA Δ1-159, well correlated to the expected channel surface area increase of ~16%. Conclusion In this study using a simple "semi rational" approach the FhuA Δ1-159 diameter was enlarged. By combining the actual results with the previous ones on the FhuA Δ1-159 lengthening a new set of synthetic nanochannels with desired lengths and diameters can be produced, broadening the FhuA Δ1-159 applications. As large scale protein production is possible our approach can give a contribution to nanochannel industrial applications.

  1. An eigenfunction method for reconstruction of large-scale and high-contrast objects.

    Science.gov (United States)

    Waag, Robert C; Lin, Feng; Varslot, Trond K; Astheimer, Jeffrey P

    2007-07-01

    A multiple-frequency inverse scattering method that uses eigenfunctions of a scattering operator is extended to image large-scale and high-contrast objects. The extension uses an estimate of the scattering object to form the difference between the scattering by the object and the scattering by the estimate of the object. The scattering potential defined by this difference is expanded in a basis of products of acoustic fields. These fields are defined by eigenfunctions of the scattering operator associated with the estimate. In the case of scattering objects for which the estimate is radial, symmetries in the expressions used to reconstruct the scattering potential greatly reduce the amount of computation. The range of parameters over which the reconstruction method works well is illustrated using calculated scattering by different objects. The method is applied to experimental data from a 48-mm diameter scattering object with tissue-like properties. The image reconstructed from measurements has, relative to a conventional B-scan formed using a low f-number at the same center frequency, significantly higher resolution and less speckle, implying that small, high-contrast structures can be demonstrated clearly using the extended method.

  2. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  3. Diameter-dependent coloration of silver nanowires

    International Nuclear Information System (INIS)

    Stewart, Mindy S; Qiu Chao; Jiang Chaoyang; Kattumenu, Ramesh; Singamaneni, Srikanth

    2011-01-01

    Silver nanowires were synthesized with a green method and characterized with microscopic and diffractometric methods. The correlation between the colors of the nanowires deposited on a solid substrate and their diameters was explored. Silver nanowires that appear similar in color in the optical micrographs have very similar diameters as determined by atomic force microscopy. We have summarized the diameter-dependent coloration for these silver nanowires. An optical interference model was applied to explain such correlation. In addition, microreflectance spectra were obtained from individual nanowires and the observed spectra can be explained with the optical interference theory. This work provides a cheap, quick and simple screening method for studying the diameter distribution of silver nanowires, as well as the diameter variations of individual silver nanowires, without complicated sample preparation.

  4. Final Report: DoE SBIR Phase 2 Low-Cost Small Diameter NMR Technologies for In-Situ Subsurface Characterization and Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, David Oliver [Vista Clara Inc., Mukilteo, WA (United States)

    2010-09-03

    In this Phase 2 SBIR program, Vista Clara successfully developed and field-tested small diameter NNR logging tools for subsurface characterization and monitoring. This effort involved the design and development surface electronics, a winch with 470ft cable, and three interchangeable downhole probes: a 3.5â diameter borehole NMR probe, a 1.67â diameter borehole NMR probe, and a 2.5â diameter NMR probe that can be deployed using a Geoprobe direct push machine. The 3.5â probe was tested extensively over a 6 week period including 4â to 8â boreholes in Washington, Idaho, Nebraska, Colorado, Kansas, Connecticut and Massachusetts. The field test campaign was highly successful. The 1.67â probe was assembled, tested and calibrated in the laboratory. The 2.5â Geoprobe probe is in final assembly and testing at the time of this report. The completed Phase 2 R&D program has resulted in the first NMR logging tool that can be deployed in boreholes of 4â diameter, the first NMR logging tool that can be deployed in boreholes on 2â diameter, and the first NMR logging tool that can be deployed by a direct push machine. These small diameter tools make NMR logging technically and economically feasible, for the first time. Previously available NMR logging tools were developed for oilfield applications and are prohibitively large and expensive for the majority of near surface groundwater characterization problems.

  5. 7 CFR 51.320 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter...

  6. A six-bank multi-leaf system for high precision shaping of large fields

    International Nuclear Information System (INIS)

    Topolnjak, R; Heide, U A van der; Raaymakers, B W; Kotte, A N T J; Welleweerd, J; Lagendijk, J J W

    2004-01-01

    In this study, we present the design for an alternative MLC system that allows high precision shaping of large fields. The MLC system consists of three layers of two opposing leaf banks. The layers are rotated 60 deg. relative to each other. The leaves in each bank have a standard width of 1 cm projected at the isocentre. Because of the symmetry of the collimator set-up it is expected that collimator rotation will not be required, thus simplifying the construction considerably. A 3D ray tracing computer program was developed in order to simulate the fluence profile for a given collimator and used to optimize the design and investigate its performance. The simulations show that a six-bank collimator will afford field shaping of fields of about 40 cm diameter with a precision comparable to that of existing mini MLCs with a leaf width of 4 mm

  7. Determining the Optimum Inner Diameter of Condenser Tubes Based on Thermodynamic Objective Functions and an Economic Analysis

    Directory of Open Access Journals (Sweden)

    Rafał Laskowski

    2016-12-01

    Full Text Available The diameter and configuration of tubes are important design parameters of power condensers. If a proper tube diameter is applied during the design of a power unit, a high energy efficiency of the condenser itself can be achieved and the performance of the whole power generation unit can be improved. If a tube assembly is to be replaced, one should verify whether the chosen condenser tube diameter is correct. Using a diameter that is too large increases the heat transfer area, leading to over-dimensioning and higher costs of building the condenser. On the other hand, if the diameter is too small, water flows faster through the tubes, which results in larger flow resistance and larger pumping power of the cooling-water pump. Both simple and complex methods can be applied to determine the condenser tube diameter. The paper proposes a method of technical and economic optimisation taking into account the performance of a condenser, the low-pressure (LP part of a turbine, and a cooling-water pump as well as the profit from electric power generation and costs of building the condenser and pumping cooling water. The results obtained by this method were compared with those provided by the following simpler methods: minimization of the entropy generation rate per unit length of a condenser tube (considering entropy generation due to heat transfer and resistance of cooling-water flow, minimization of the total entropy generation rate (considering entropy generation for the system comprising the LP part of the turbine, the condenser, and the cooling-water pump, and maximization of the power unit’s output. The proposed methods were used to verify diameters of tubes in power condensers in a200-MW and a 500-MW power units.

  8. Diameter-tailored telecom-band luminescence in InP/InAs heterostructure nanowires grown on InP (111)B substrate with continuously-modulated diameter from microscale to nanoscale

    Science.gov (United States)

    Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki

    2018-04-01

    We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.

  9. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO3 nanowires with high length–diameter ratio

    International Nuclear Information System (INIS)

    Liu, Hui; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-01-01

    WO 3 nanowires (WO 3 NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO 3 NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO 3 NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO 3 nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO 3 nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO 3 NWs with high length–diameter ratio have been synthesized. • The WO 3 NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite

  10. Precision Optical Coatings for Large Space Telescope Mirrors

    Science.gov (United States)

    Sheikh, David

    This proposal “Precision Optical Coatings for Large Space Telescope Mirrors” addresses the need to develop and advance the state-of-the-art in optical coating technology. NASA is considering large monolithic mirrors 1 to 8-meters in diameter for future telescopes such as HabEx and LUVOIR. Improved large area coating processes are needed to meet the future requirements of large astronomical mirrors. In this project, we will demonstrate a broadband reflective coating process for achieving high reflectivity from 90-nm to 2500-nm over a 2.3-meter diameter coating area. The coating process is scalable to larger mirrors, 6+ meters in diameter. We will use a battery-driven coating process to make an aluminum reflector, and a motion-controlled coating technology for depositing protective layers. We will advance the state-of-the-art for coating technology and manufacturing infrastructure, to meet the reflectance and wavefront requirements of both HabEx and LUVOIR. Specifically, we will combine the broadband reflective coating designs and processes developed at GSFC and JPL with large area manufacturing technologies developed at ZeCoat Corporation. Our primary objectives are to: Demonstrate an aluminum coating process to create uniform coatings over large areas with near-theoretical aluminum reflectance Demonstrate a motion-controlled coating process to apply very precise 2-nm to 5- nm thick protective/interference layers to large areas, Demonstrate a broadband coating system (90-nm to 2500-nm) over a 2.3-meter coating area and test it against the current coating specifications for LUVOIR/HabEx. We will perform simulated space-environment testing, and we expect to advance the TRL from 3 to >5 in 3-years.

  11. An experimental investigation of forced convection burnout in high pressure water. Part IV, Large diameter tubes at about 1600 p.s.i

    International Nuclear Information System (INIS)

    Lee, D.H.

    1966-11-01

    The report presents 727 burnout results for tubes with uniform and non-uniform axial heat flux profiles. Most of the data are at 1600 p.s.i, although there are a limited number at 1250 and 1800 p.s.i. Tube diameters ranged from 0.5 to 1.8 inches. A new correlation for uniform flax data at these pressures is presented, having R.M.S. errors between 4 and 6%. A table of constant terms for this new uniform flux correlation is given, together with Macbeth's values for pressures of 560, 1000 and 2000 p.s.i. Experimental and predicted burnout powers for non-uniform axial heat fluxes are compared and the existing methods of prediction are found to be in error by up to 20%. A new method for predicting burnout with non-uniform axial heat flux is developed which correlates all published data to an R.M.S. error of 6.7%. (author)

  12. Tree height-diameter allometry across the United States.

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-03-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height-diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales.

  13. Tree height–diameter allometry across the United States

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-01-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height–diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales. PMID:25859325

  14. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  15. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  16. High-Speed Measurement of the Internal Diameter of Tubes: A Comparison of Methods

    DEFF Research Database (Denmark)

    Gundtoft, Hans Erik; Agerup, C.C.; Nielsen, N.

    1974-01-01

    The authors have compared various methods of tube measurement and have made the striking conclusion that the continuous measurement of the internal diameter of precision tubes with an air gauge is often useless in practice. The methods selected for experiment were all contactless and so included...

  17. Arterial diameter during central volume depletion in humans

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Madsen, P; Matzen, S

    1995-01-01

    The luminal diameter of the radial artery was followed by high frequency ultrasound during 50 degrees head-up tilt-induced central volume depletion in ten healthy subjects of whom six were tilted twice and pretreated with the serotonin receptor antagonist methysergide or placebo following a double...

  18. Observation of diameter dependent carrier distribution in nanowire-based transistors

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, A; Hantschel, T; Eyben, P; Verhulst, A S; Rooyackers, R; Vandooren, A; Mody, J; Nazir, A; Leonelli, D; Vandervorst, W, E-mail: Andreas.Schulze@imec.be [IMEC, Kapeldreef 75, 3001 Leuven (Belgium)

    2011-05-06

    The successful implementation of nanowire (NW) based field-effect transistors (FET) critically depends on quantitative information about the carrier distribution inside such devices. Therefore, we have developed a method based on high-vacuum scanning spreading resistance microscopy (HV-SSRM) which allows two-dimensional (2D) quantitative carrier profiling of fully integrated silicon NW-based tunnel-FETs (TFETs) with 2 nm spatial resolution. The key elements of our characterization procedure are optimized NW cleaving and polishing steps, the use of in-house fabricated ultra-sharp diamond tips, measurements in high vacuum and a dedicated quantification procedure accounting for the Schottky-like tip-sample contact affected by surface states. In the case of the implanted TFET source regions we find a strong NW diameter dependence of conformality, junction abruptness and gate overlap, quantitatively in agreement with process simulations. In contrast, the arsenic doped drain regions reveal an unexpected NW diameter dependent dopant deactivation. The observed lower drain doping for smaller diameters is reflected in the device characteristics by lower TFET off-currents, as measured experimentally and confirmed by device simulations.

  19. Variable-Frequency Ultrasonic Treatment on Microstructure and Mechanical Properties of ZK60 Alloy during Large Diameter Semi-Continuous Casting

    Directory of Open Access Journals (Sweden)

    Xingrui Chen

    2017-05-01

    Full Text Available Traditional fixed-frequency ultrasonic technology and a variable-frequency ultrasonic technology were applied to refine the as-cast microstructure and improve the mechanical properties of a ZK60 (Mg–Zn–Zr alloy during large diameter semi-continuous casting. The acoustic field propagation was obtained by numerical simulation. The microstructure of the as-cast samples was characterized by optical and scanning electron microscopy. The variable-frequency ultrasonic technology shows its outstanding ability in grain refinement compared with traditional fixed-ultrasonic technology. The variable-frequency acoustic field promoted the formation of small α-Mg globular grains and changed the distribution and morphology of β-phases throughout the castings. Ultimate tensile strength and elongation are increased to 280 MPa and 8.9%, respectively, which are 19.1% and 45.9% higher than the values obtained from billets without ultrasonic treatment and are 11.6% and 18.7% higher than fixed-frequency ultrasound treated billets. Different refinement efficiencies appear in different districts of billets attributed to the sound attenuation in melt. The variable-frequency acoustic field improves the refinement effect by enhancing cavitation-enhanced heterogeneous nucleation and dendrite fragmentation effects.

  20. Dose and diameter relationships for facial, trigeminal, and acoustic neuropathies following acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Lunsford, L. Dade

    1996-01-01

    Purpose and objective: To define the relationships between dose and tumor diameter for the risks of developing trigeminal, facial, and acoustic neuropathies after acoustic neuroma radiosurgery, a large single-institution experience was analyzed. Materials and methods: Two hundred and thirty-eight patients with unilateral acoustic neuromas who underwent Gamma knife radiosurgery between 1987-1994 with 6-91 months of follow-up (median 30 months) were studied. Minimum tumor doses were 12-20 Gy (median 15 Gy). Transverse tumor diameter varied from 0.3-5.5 cm (median 2.1 cm). The relationships of dose and diameter to the development of cranial neuropathies were delineated by multivariate logistic regression. Results: The development of post-radiosurgery neuropathies affecting cranial nerves V, VII, and VIII were correlated with minimum tumor dose and transverse tumor diameter (P min for VIII where P=0.10). A comparison of the dose-diameter response curves showed the acoustic nerve to be the most sensitive to doses of 12-16 Gy and the facial nerve to be the least sensitive. Conclusion: The risks of developing trigeminal, facial, and acoustic neuropathies following acoustic neuroma radiosurgery can be predicted from the transverse tumor diameter and the minimum tumor dose using models constructed from data presently available

  1. Biodegradable Magnetic Silica@Iron Oxide Nanovectors with Ultra-Large Mesopores for High Protein Loading, Magnetothermal Release, and Delivery

    KAUST Repository

    Omar, Haneen; Croissant, Jonas G.; Alamoudi, Kholod; Alsaiari, Shahad K.; Alradwan, Ibrahim; Majrashi, Majed A.; Anjum, Dalaver H.; Martins, Patricia; Moosa, Basem; Almalik, Abdulaziz; Khashab, Niveen M.

    2016-01-01

    The delivery of large cargos of diameter above 15 nm for biomedical applications has proved challenging since it requires biocompatible, stably-loaded, and biodegradable nanomaterials. In this study, we describe the design of biodegradable silica

  2. Spontaneous high frequency diameter oscillations of larger retinal arterioles are reduced in type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Bek, Toke; Jeppesen, Peter; Kanters, Jørgen K.

    2013-01-01

    Diabetic retinopathy is characterized by morphological changes in the retina secondary to disturbances in retinal blood flow. Vasomotion is a mechanism for regulating blood flow by spontaneous oscillations in the diameter of retinal resistance arterioles, and has been shown to be disturbed outside...... the eye in diabetic patients. Therefore, the purpose of the present study was to characterize spontaneous oscillations in the diameter of retinal arterioles in normal persons and in persons with different severity of diabetic retinopathy....

  3. Niobium oxide nanocolumns formed via anodic alumina with modulated pore diameters

    Science.gov (United States)

    Pligovka, A.; Zakhlebayeva, A.; Lazavenka, A.

    2018-03-01

    Niobium oxide nanocolumns with modulated diameters were formed for the first time. An Al/Nb bilayer specimen was prepared by successive sputter-deposition of 300 nm niobium layer and 1200 nm aluminum layer onto silicon wafer. Regular anodic alumina matrix with modulated pore diameters was formed by sequential anodization of initial specimen in tartaric acid at 180 V, and in oxalic acid at 37 V. Further potentiodynamic reanodization of the specimen up to 400 V causes the simultaneous growth of 440 nm continuous niobium oxide layer beneath the alumina film and two types of an array of oxide nanocolumns (thick – with 100 nm width and 630 nm high and thin – with 25 nm width and 170 nm high), which are the filling of the alumina pores. The morphology of the formed anodic niobium oxide nanocolumns with modulated diameters was determined by field emission scanning electron microscopy. The formed nanostructures can be used for perspective devices of nano- and optoelectronics such as photonic crystals.

  4. Synthesis of subnanometer-diameter vertically aligned single-walled carbon nanotubes with copper-anchored cobalt catalysts

    Science.gov (United States)

    Cui, Kehang; Kumamoto, Akihito; Xiang, Rong; An, Hua; Wang, Benjamin; Inoue, Taiki; Chiashi, Shohei; Ikuhara, Yuichi; Maruyama, Shigeo

    2016-01-01

    We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high-quality SWNTs are expected to pave the way to replace silicon for next-generation optoelectronic and photovoltaic devices.We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high

  5. The effect of nozzle diameter, injection pressure and ambient temperature on spray characteristics in diesel engine

    Science.gov (United States)

    Rhaodah Andsaler, Adiba; Khalid, Amir; Sharifhatul Adila Abdullah, Nor; Sapit, Azwan; Jaat, Norrizam

    2017-04-01

    Mixture formation of the ignition process is a key element in the diesel combustion as it influences the combustion process and exhaust emission. Aim of this study is to elucidate the effects of nozzle diameter, injection pressure and ambient temperature to the formation of spray. This study investigated diesel formation spray using Computational Fluid Dynamics. Multiphase volume of fluid (VOF) behaviour in the chamber are determined by means of transient simulation, Eulerian of two phases is used for implementation of mixing fuel and air. The detail behaviour of spray droplet diameter, spray penetration and spray breakup length was visualised using the ANSYS 16.1. This simulation was done in different nozzle diameter 0.12 mm and 0.2 mm performed at the ambient temperature 500 K and 700 K with different injection pressure 40 MPa, 70 MPa and 140 MPa. Results show that high pressure influence droplet diameter become smaller and the penetration length longer with the high injection pressure apply. Smaller nozzle diameter gives a shorter length of the breakup. It is necessary for nozzle diameter and ambient temperature condition to improve the formation of spray. High injection pressure is most effective in improvement of formation spray under higher ambient temperature and smaller nozzle diameter.

  6. Design of large-format X-ray framing image tube

    International Nuclear Information System (INIS)

    Zong Fangke; Yang Qinlao; Gu Li; Li Xiang; Zhang Jingjin

    2012-01-01

    An implementation method of large-format framing image tube is proposed. An electrostatic focusing image tube with large input photocathode and small output image is designed. Coupling with common small-format microchannel plate (MCP) gated framing unit, image gating and enhancement can be realized. Compared to the tube with large-format MCP, this kind of framing tube avoids the high manufacturing cost of lager-format MCP and overcomes the transmission voltage loss and gain uniformity caused by long micro strips. The framing image tube has an effective input working diameter of 100 mm, an output image diameter of 40 mm, and a magnification of 0.4. The centre spatial resolution is 14.4 lp/mm, the marginal spatial resolution is 11.2 lp/mm, and the the geometric distortion is less than 15%. The framing characteristics is determined by the MCP framing unit. This method is an effective way for expanding the work area of framing image tubes. (authors)

  7. Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    CERN Document Server

    Bittner, Bernhard; Kortner, Oliver; Kroha, Hubert; Manfredini, Alessandro; Nowak, Sebastian; Ott, Sebastian; Richter, Robert; Schwegler, Philipp; Zanzi, Daniele; Biebel, Otmar; Hertenberger, Ralf; Ruschke, Alexander; Zibell, Andre

    2016-01-01

    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking e?ciency and spatial resolution at high counting rates will be achieved with ...

  8. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO{sub 3} nanowires with high length–diameter ratio

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui, E-mail: liuhui@sust.edu.cn; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-08-01

    WO{sub 3} nanowires (WO{sub 3}NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO{sub 3}NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO{sub 3}NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO{sub 3} nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO{sub 3} nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO{sub 3}NWs with high length–diameter ratio have been synthesized. • The WO{sub 3}NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite.

  9. Growth of high-quality large-area MgB2 thin films by reactive evaporation

    International Nuclear Information System (INIS)

    Moeckly, B H; Ruby, W S

    2006-01-01

    We report a new in situ reactive deposition thin film growth technique for the production of MgB 2 thin films which offers several advantages over all existing methods and is the first deposition method to enable the production of high-quality MgB 2 films for real-world applications. We have used this growth method, which incorporates a rotating pocket heater, to deposit MgB 2 films on a variety of substrates, including single-crystalline, polycrystalline, metallic, and semiconductor materials up to 4 inch in diameter. This technique allows growth of double-sided, large-area films in the intermediate temperature range of 400-600 deg. C. These films are clean, well-connected, and consistently display T c values of 38-39 K with low resistivity and residual resistivity values. They are also robust and uncommonly stable upon exposure to atmosphere and water. (rapid communication)

  10. Soil-Structure Interaction For Nonslender, Large-Diameter Offshore Monopiles

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal

    Strong political and industrial forces, especially in Northern Europe, support the development of new technologies as well as improvements of existing technologies within the field of renewable energy. Offshore wind power is a domestic, sustainable and largely untapped energy resource. Today......, the modern offshore wind turbine offers competitive production prices compared to other sources of renewable energy. Therefore, it is a key technology in breaking the dependence on fossil fuels and in achieving the energy and climate goals of the future. For offshore wind turbines, the costs of foundation...... typically constitutes 20-30 % of the total costs. Hence, improved methods for the design of foundations for offshore wind turbines can increase the competitiveness of offshore wind energy significantly. The monopile foundation concept has been employed as the foundation for the majority of the currently...

  11. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  12. Preparation of three-dimensionally ordered macroporous perovskite-type lanthanum-iron-oxide LaFeO3 with tunable pore diameters: High porosity and photonic property

    International Nuclear Information System (INIS)

    Sadakane, Masahiro; Horiuchi, Toshitaka; Kato, Nobuyasu; Sasaki, Keisuke; Ueda, Wataru

    2010-01-01

    Three-dimensionally ordered macroporous (3DOM) lanthanum-iron-oxide (LaFeO 3 ) with different pore diameters was prepared using a colloidal crystal of polymer spheres with different diameters as templates. Ethylene glycol-methanol mixed solution of metal nitrates was infiltrated into the void of the colloidal crystal template of a monodispersed poly(methyl methacrylate) (PMMA) sphere. Heating of this PMMA-metal salt-ethylene glycol composite produced the desired well-ordered 3DOM LaFeO 3 with a high pore fraction, which was confirmed by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), mercury (Hg) porosimetry, and ultraviolet-visible (UV-vis) diffuse reflectance spectra. 3DOM LaFeO 3 with pore diameters of 281 and 321 nm shows opalescent colors because of photonic stop band properties. Catalytic activity of the 3DOM LaFeO 3 for combustion of carbon particles was enhanced by a potassium cation, which was involved from K 2 S 2 O 8 used as a polymerization initiator. - Graphical abstract: Well-ordered three-dimensionally ordered macroporous LaFeO 3 materials with pore sizes ranging from 127 to 321 nm were obtained in a high pore fraction.

  13. Dynamic Soil-Pile Interaction for large diameter monopile foundations

    DEFF Research Database (Denmark)

    Zania, Varvara

    2013-01-01

    of the study is to analyse the dynamic interaction of the soil and a single pile embedded in it by accounting for the geometric and stiffness properties of the pile. In doing so, a semi – analytical approach is adopted based on the fundamental solution of horizontal pile vibration by Novak and Nogami (1977...... eigenfrequencies of the soil layer do not affect the soil – pile interaction. The decrease of the eigefrequency of the OWT depends on the aforementioned variation of the dynamic stiffness and the slenderness ratio of the monopile.......Monopile foundations have been used in a large extent to support offshore wind turbines (OWT), being considered as a reliable and cost effective design solution. The accurate estimation of their dynamic response characteristics is essential, since the design of support structures for OWTs has been...

  14. Optical spectroscopy of iodine-doped single-wall carbon nanotubes of different diameter

    International Nuclear Information System (INIS)

    Tonkikh, Alexander A.; Obraztsova, Elena D.; Pozharov, Anatolii S.; Obraztsova, Ekaterina A.; Belkin, Alexey V.

    2012-01-01

    Single-wall carbon nanotubes with polyiodide chains inside are interesting from two points of view. According to predictions, first, the iodine structure type inside the nanotube is determined by the nanotube geometry. Second, after iodination all nanotubes become metallic. In this work, we made an attempt to check both predictions. To study the diameter-dependent properties we have taken for a gas-phase iodination the pristine single-wall carbon nanotubes grown by three different techniques providing a different average diameter: a chemical vapor deposition with a Co/Mo catalyst (CoMoCat) with a diameter range (0.6-1.3) nm, a high-pressure CO decomposition (HiPCO) - a diameter range (0.8-1.5) nm, and an aerosol technique with Fe catalyst - a diameter range (1.3-2.0) nm. The Raman spectra have shown a complication of the polyiodide chain structure while the nanotube diameter increased. The optical spectroscopy data (a suppression of E 11 band in the UV-Vis-NIR absorption spectrum) have confirmed the theoretical prediction about transformation of all nanotubes into metallic phase after doping. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Classic beta-amyloid deposits cluster around large diameter blood vessels rather than capillaries in sporadic Alzheimer's disease.

    Science.gov (United States)

    Armstrong, Richard A

    2006-11-01

    Various hypotheses could explain the relationship between beta-amyloid (Abeta) deposition and the vasculature in Alzheimer's disease (AD). Amyloid deposition may reduce capillary density, affect endothelial cells of blood vessels, result in diffusion from blood vessels, or interfere with the perivascular clearance mechanism. Hence, the spatial pattern of the classic ('cored') type of Abeta deposit was studied in the upper laminae (I,II/III) of the superior frontal gyrus in nine cases of sporadic AD (SAD). Sections were immunostained with antibodies against Abeta and with collagen IV to study the relationships between the spatial distribution of the classic deposits and the blood vessel profiles. Both the classic deposits and blood vessel profiles were distributed in clusters. In all cases, there was a positive spatial correlation between the clusters of the classic deposits and the larger diameter (>10 microm) blood vessel profiles and especially the vertically penetrating arterioles. In only 1 case, was there a significant spatial correlation between the clusters of the classic deposits and the smaller diameter (upper laminae of the frontal cortex. This aggregation could result from diffusion of proteins from blood vessels or from overloading the system of perivascular clearance from the brain.

  16. Structural-electromagnetic bidirectional coupling analysis of space large film reflector antennas

    Science.gov (United States)

    Zhang, Xinghua; Zhang, Shuxin; Cheng, ZhengAi; Duan, Baoyan; Yang, Chen; Li, Meng; Hou, Xinbin; Li, Xun

    2017-10-01

    As used for energy transmission, a space large film reflector antenna (SLFRA) is characterized by large size and enduring high power density. The structural flexibility and the microwave radiation pressure (MRP) will lead to the phenomenon of structural-electromagnetic bidirectional coupling (SEBC). In this paper, the SEBC model of SLFRA is presented, then the deformation induced by the MRP and the corresponding far field pattern deterioration are simulated. Results show that, the direction of the MRP is identical to the normal of the reflector surface, and the magnitude is proportional to the power density and the square of cosine incident angle. For a typical cosine function distributed electric field, the MRP is a square of cosine distributed across the diameter. The maximum deflections of SLFRA linearly increase with the increasing microwave power densities and the square of the reflector diameters, and vary inversely with the film thicknesses. When the reflector diameter becomes 100 m large and the microwave power density exceeds 102 W/cm2, the gain loss of the 6.3 μm-thick reflector goes beyond 0.75 dB. When the MRP-induced deflection degrades the reflector performance, the SEBC should be taken into account.

  17. LLNL large-area inductively coupled plasma (ICP) source: Experiments

    International Nuclear Information System (INIS)

    Richardson, R.A.; Egan, P.O.; Benjamin, R.D.

    1995-05-01

    We describe initial experiments with a large (76-cm diameter) plasma source chamber to explore the problems associated with large-area inductively coupled plasma (ICP) sources to produce high density plasmas useful for processing 400-mm semiconductor wafers. Our experiments typically use a 640-nun diameter planar ICP coil driven at 13.56 MHz. Plasma and system data are taken in Ar and N 2 over the pressure range 3-50 mtorr. RF inductive power was run up to 2000W, but typically data were taken over the range 100-1000W. Diagnostics include optical emission spectroscopy, Langmuir probes, and B probes as well as electrical circuit measurements. The B and E-M measurements are compared with models based on commercial E-M codes. Initial indications are that uniform plasmas suitable for 400-mm processing are attainable

  18. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  19. Comparative study of new 130mm diameter fast photomultipliers for neutron detectors

    International Nuclear Information System (INIS)

    Moszynski, M.; Costa, G.J.; Guillaume, G.; Heusch, B.; Huck, A.; Mouatassim, S.

    1991-01-01

    The present paper is a summary of the test measurements carried out using new 130 mm diameter fast photomultiplier tubes manufactured by Philips (France), EMI (England) and Hamamatsu (Japan), along with a comparison to the results obtained with the well known XP 2041 Philips model. These tubes will be used in large size neutron detectors

  20. The AKARI IRC asteroid flux catalogue: updated diameters and albedos

    Science.gov (United States)

    Alí-Lagoa, V.; Müller, T. G.; Usui, F.; Hasegawa, S.

    2018-05-01

    The AKARI IRC all-sky survey provided more than twenty thousand thermal infrared observations of over five thousand asteroids. Diameters and albedos were obtained by fitting an empirically calibrated version of the standard thermal model to these data. After the publication of the flux catalogue in October 2016, our aim here is to present the AKARI IRC all-sky survey data and discuss valuable scientific applications in the field of small body physical properties studies. As an example, we update the catalogue of asteroid diameters and albedos based on AKARI using the near-Earth asteroid thermal model (NEATM). We fit the NEATM to derive asteroid diameters and, whenever possible, infrared beaming parameters. We fit groups of observations taken for the same object at different epochs of the survey separately, so we compute more than one diameter for approximately half of the catalogue. We obtained a total of 8097 diameters and albedos for 5170 asteroids, and we fitted the beaming parameter for almost two thousand of them. When it was not possible to fit the beaming parameter, we used a straight line fit to our sample's beaming parameter-versus-phase angle plot to set the default value for each fit individually instead of using a single average value. Our diameters agree with stellar-occultation-based diameters well within the accuracy expected for the model. They also match the previous AKARI-based catalogue at phase angles lower than 50°, but we find a systematic deviation at higher phase angles, at which near-Earth and Mars-crossing asteroids were observed. The AKARI IRC All-sky survey is an essential source of information about asteroids, especially the large ones, since, it provides observations at different observation geometries, rotational coverages and aspect angles. For example, by comparing in more detail a few asteroids for which dimensions were derived from occultations, we discuss how the multiple observations per object may already provide three

  1. Status of the variable diameter centerbody inlet program

    Science.gov (United States)

    Saunders, John D.; Linne, A. A.

    1992-01-01

    The Variable Diameter Centerbody (VDC) inlet is an ongoing research program at LeRC. The VDC inlet is a mixed compression, axisymmetric inlet that has potential application on the next generation supersonic transport. This inlet was identified as one of the most promising axisymmetric concepts for supersonic cruise aircraft during the SCAR program in the late 1970's. Some of its features include high recovery, low bleed, good angle-of-attack tolerance, and excellent engine airflow matching. These features were demonstrated at LeRC in the past by the design and testing of fixed hardware models. A current test program in the LeRC 10' x 10' Supersonic Wind Tunnel (SWT) will attempt to duplicate these features on model hardware that actually incorporates a flight-like variable diameter centerbody mechanism.

  2. Large area high-speed metrology SPM system

    International Nuclear Information System (INIS)

    Klapetek, P; Valtr, M; Martinek, J; Picco, L; Payton, O D; Miles, M; Yacoot, A

    2015-01-01

    We present a large area high-speed measuring system capable of rapidly generating nanometre resolution scanning probe microscopy data over mm 2 regions. The system combines a slow moving but accurate large area XYZ scanner with a very fast but less accurate small area XY scanner. This arrangement enables very large areas to be scanned by stitching together the small, rapidly acquired, images from the fast XY scanner while simultaneously moving the slow XYZ scanner across the region of interest. In order to successfully merge the image sequences together two software approaches for calibrating the data from the fast scanner are described. The first utilizes the low uncertainty interferometric sensors of the XYZ scanner while the second implements a genetic algorithm with multiple parameter fitting during the data merging step of the image stitching process. The basic uncertainty components related to these high-speed measurements are also discussed. Both techniques are shown to successfully enable high-resolution, large area images to be generated at least an order of magnitude faster than with a conventional atomic force microscope. (paper)

  3. Large area high-speed metrology SPM system

    Science.gov (United States)

    Klapetek, P.; Valtr, M.; Picco, L.; Payton, O. D.; Martinek, J.; Yacoot, A.; Miles, M.

    2015-02-01

    We present a large area high-speed measuring system capable of rapidly generating nanometre resolution scanning probe microscopy data over mm2 regions. The system combines a slow moving but accurate large area XYZ scanner with a very fast but less accurate small area XY scanner. This arrangement enables very large areas to be scanned by stitching together the small, rapidly acquired, images from the fast XY scanner while simultaneously moving the slow XYZ scanner across the region of interest. In order to successfully merge the image sequences together two software approaches for calibrating the data from the fast scanner are described. The first utilizes the low uncertainty interferometric sensors of the XYZ scanner while the second implements a genetic algorithm with multiple parameter fitting during the data merging step of the image stitching process. The basic uncertainty components related to these high-speed measurements are also discussed. Both techniques are shown to successfully enable high-resolution, large area images to be generated at least an order of magnitude faster than with a conventional atomic force microscope.

  4. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  5. Effect of particle diameter of porous media on flow and heat transfer in a mixing tee

    International Nuclear Information System (INIS)

    Wang, Yongwei; Lu, Tao; Wang, Kuisheng

    2012-01-01

    Highlights: ► Three particle diameter cases of 28 mm, 14 mm and 7 mm were simulated by LES. ► With the diameter decreasing, mixing scale tends to decrease in the mixing tee. ► With the diameter decreasing, thermal mixing is weakened. ► With the diameter decreasing, the thermal stratification is obvious. ► When the particle diameter ratio is 4:2:1, pressure drop ratio is 1:2:4. -- Abstract: Numerical simulations have been carried out to investigate flow and heat transfer in a mixing tee filled with periodic sintered copper spheres. Three particle diameter cases of 28 mm, 14 mm and 7 mm with the array of 4 × 4, 8 × 8 and 16 × 16 at the same porosity of 0.3 have been calculated using large-eddy simulations and the Smagorinsky–Lilly sub-grid scale model. With the particle diameter decreasing, the mixture scale of hot and cold fluid tends to decrease in the mixing tee; the pressure drop of fluid flow through porous media increases. When the particle diameter ratios are 4:2:1 and the specific surface ratios are 1:2:4, the pressure drop ratios are 1:2:4; the thermal mixing in porous media is weakened because the temperature fluctuation decreases and the stratification of hot and cold fluids is observed.

  6. Large-Eddy Simulation of a High Reynolds Number Flow Around a Cylinder Including Aeroacoustic Predictions

    Science.gov (United States)

    Spyropoulos, Evangelos T.; Holmes, Bayard S.

    1997-01-01

    The dynamic subgrid-scale model is employed in large-eddy simulations of flow over a cylinder at a Reynolds number, based on the diameter of the cylinder, of 90,000. The Centric SPECTRUM(trademark) finite element solver is used for the analysis. The far field sound pressure is calculated from Lighthill-Curle's equation using the computed fluctuating pressure at the surface of the cylinder. The sound pressure level at a location 35 diameters away from the cylinder and at an angle of 90 deg with respect to the wake's downstream axis was found to have a peak value of approximately 110 db. Slightly smaller peak values were predicted at the 60 deg and 120 deg locations. A grid refinement study suggests that the dynamic model demands mesh refinement beyond that used here.

  7. Large area avalanche MRS-photodiodes for nuclear spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ermalitski, F A; Zalesski, V B

    1996-12-31

    Problems of application of avalanche photodiodes (APD) in readout systems of nuclear spectrometers are considered. APD`s with a large sensitive area of a diameter 1-5 mm and a high multiplication coefficient 200-1000 are created. MPS-photodiodes provide for the energy resolution 80% at temperature 231 K for detecting gamma-quanta with energy 662 keV. 4 refs.

  8. Methods for the performance enhancement and the error characterization of large diameter ground-based diffractive telescopes.

    Science.gov (United States)

    Zhang, Haolin; Liu, Hua; Lizana, Angel; Xu, Wenbin; Caompos, Juan; Lu, Zhenwu

    2017-10-30

    This paper is devoted to the improvement of ground-based telescopes based on diffractive primary lenses, which provide larger aperture and relaxed surface tolerance compared to non-diffractive telescopes. We performed two different studies devised to thoroughly characterize and improve the performance of ground-based diffractive telescopes. On the one hand, we experimentally validated the suitability of the stitching error theory, useful to characterize the error performance of subaperture diffractive telescopes. On the other hand, we proposed a novel ground-based telescope incorporated in a Cassegrain architecture, leading to a telescope with enhanced performance. To test the stitching error theory, a 300 mm diameter, 2000 mm focal length transmissive stitching diffractive telescope, based on a three-belt subaperture primary lens, was designed and implemented. The telescope achieves a 78 cy/mm resolution within 0.15 degree field of view while the working wavelength ranges from 582.8 nm to 682.8 nm without any stitching error. However, the long optical track (35.49 m) introduces air turbulence that reduces the final images contrast in the ground-based test. To enhance this result, a same diameter compacted Cassegrain ground-based diffractive (CGD) telescope with the total track distance of 1.267 m, was implemented within the same wavelength. The ground-based CGD telescope provides higher resolution and better contrast than the transmissive configuration. Star and resolution tests were experimentally performed to compare the CGD and the transmissive configurations, providing the suitability of the proposed ground-based CGD telescope.

  9. The dependence of the optoelectrical properties of silver nanowire networks on nanowire length and diameter

    International Nuclear Information System (INIS)

    Sorel, Sophie; Lyons, Philip E; De, Sukanta; Coleman, Jonathan N; Dickerson, Janet C

    2012-01-01

    We have characterized the optoelectrical properties of networks of silver nanowires as a function of nanowire dimension by measuring transmittance (T) and sheet resistance (R s ) for a large number of networks of different thicknesses fabricated from wires of different diameters (D) and lengths (L). We have analysed these data using both bulk-like and percolative models. We find the network DC conductivity to scale linearly with wire length while the optical conductivity is approximately invariant with nanowire length. The ratio of DC to optical conductivity, often taken as a figure of merit for transparent conductors, scales approximately as L/D. Interestingly, the percolative exponent, n, scales empirically as D 2 , while the percolative figure of merit, Π, displays large values at low D. As high T and low R s are associated with low n and high Π, these data are consistent with improved optoelectrical performance for networks of low-D wires. We predict that networks of wires with D = 25 nm could give sheet resistance as low as 25 Ω/□ for T = 90%. (paper)

  10. Large pore mesoporous silica nanomaterials for application in delivery of biomolecules

    Science.gov (United States)

    Knežević, Nikola Ž.; Durand, Jean-Olivier

    2015-01-01

    Various approaches for the synthesis of mesoporous silicate nanoparticles (MSN) with large pore (LP) diameters (in the range of 3-50 nm) are reviewed in this article. The work also covers the construction of magnetic analogues of large pore-mesoporous silica nanoparticles (LPMMSN) and their biomedical applications. The constructed materials exhibit vast potential for application in the loading and delivery of large drug molecules and biomolecules. Literature reports on the application of LPMSN and LPMMSN materials for the adsorption and delivery of proteins, enzymes, antibodies, and nucleic acids are covered in depth, which exemplify their highly potent characteristics for use in drug and biomolecule delivery to diseased tissues.Various approaches for the synthesis of mesoporous silicate nanoparticles (MSN) with large pore (LP) diameters (in the range of 3-50 nm) are reviewed in this article. The work also covers the construction of magnetic analogues of large pore-mesoporous silica nanoparticles (LPMMSN) and their biomedical applications. The constructed materials exhibit vast potential for application in the loading and delivery of large drug molecules and biomolecules. Literature reports on the application of LPMSN and LPMMSN materials for the adsorption and delivery of proteins, enzymes, antibodies, and nucleic acids are covered in depth, which exemplify their highly potent characteristics for use in drug and biomolecule delivery to diseased tissues. Dedicated to Professor Jeffrey I. Zink on the occasion of his 70th birthday.

  11. Unzipping of multi-wall carbon nanotubes with different diameter distributions: Effect on few-layer graphene oxide obtention

    Science.gov (United States)

    Torres, D.; Pinilla, J. L.; Suelves, I.

    2017-12-01

    Few-layer graphene oxide (FLGO) was obtained by chemical unzipping of multi-wall carbon nanotubes (MWCNT) of different diameter distributions. MWCNT were synthesized by catalytic decomposition of methane using Fe-Mo/MgO catalysts. The variation in the Fe/Mo ratio (1, 2 and 5) was very influential in MWCNT diameter distribution and type of MWCNT obtained, including textural, chemical, structural and morphological characteristics. MWCNT diameter distribution and surface defects content had a profound impact on the characteristics of the resulting FLGO. Thus, MWCNT obtained with the catalyst with a Fe/Mo: 5 and presenting a narrow diameter distribution centered at 8.6 ± 3.3 nm led to FLGO maintaining non-oxidized graphite stacking (according to XRD analysis), lower specific surface area and higher thermostability as compared to FLGO obtained from MWCNT showing wider diameter distributions. The presence of more oxygen-containing functionalities and structural defects in large diameter nanotubes promotes the intercalation of species towards the inner layers of the nanotube, resulting in an enhanced MWCNT oxidation and opening into FLGO, what improves both micro- and mesoporosity.

  12. The blood pressure-induced diameter response of retinal arterioles decreases with increasing diabetic maculopathy

    DEFF Research Database (Denmark)

    Frederiksen, Christian Alcaraz; Jeppesen, Peter; Knudsen, Søren Tang

    2006-01-01

    A consisted of normal individuals and groups B-D consisted of type 2 diabetic patients matched for diabetes duration, age, and gender, and characterized by: Group B no retinopathy, Group C mild retinopathy, Group D maculopathy not requiring laser treatment. The diameter changes of a large retinal arteriole......+/-4.5 microm), and Group C (253+/-4.4 microm), but was significantly (p=0.006) increased in Group D (279+/-5.3 microm). CONCLUSIONS: The diameter response was reduced in type 2 diabetic patients with retinopathy, whereas retinal thickness was increased in patients with diabetic maculopathy. This suggests......BACKGROUND: The aim of the study was to compare the diameter response of retinal arterioles and retinal thickness in patients with different stages of diabetic maculopathy during an increase in the arterial blood pressure. METHODS: Four groups each consisting of 19 individuals were studied. Group...

  13. Effect of diameter and axial location on upward gas–liquid two-phase flow patterns in intermediate-scale vertical tubes

    International Nuclear Information System (INIS)

    Ansari, M.R.; Azadi, R.

    2016-01-01

    Highlights: • A vertical two-phase flow system is manufactured to study flow behavior adiabatically. • Two test sections are studied with inner diameters of 40 mm and 70 mm at two locations. • Flow pattern maps are presented for both tubes. • Effects of tube diameter and heights on pattern transition boundaries are investigated. • Three sub-patterns bubbly flow and two types of slug pattern are recognized. - Abstract: In the present research, a two-phase flow system is designed, manufactured, assembled and adjusted to study two-phase flow behavior isothermally. Test sections are tubes standing in vertical position and are made of transparent acrylic with inner diameters of 40 mm and 70 mm. Two axial locations of 1.73 m and 3.22 m are chosen for data acquisition. Flow pattern maps are presented for both tubes. Effects of tube diameter and axial location on pattern transition boundaries are investigated. Air and water are chosen as working fluids. The range of air and water superficial velocities are 0.054–9.654 m/s and 0.015–0.877 m/s for the 40 mm diameter tube, but these values are 0.038–20.44 m/s and 0.036–1.530 m/s for 70 mm diameter tube. The results show that for both tubes, increasing axial location does not affect flow transition boundaries significantly. However, slug pattern region shrinks considerably by changing tube diameter from 40 mm to 70 mm. Using image processing techniques, recorded high speed movies were investigated accurately. As a result, bubbly flow in the 40 mm tube can be divided into three sub-patterns as dispersed, agitated and agglomerated bubbly. Also, two types of slug pattern are also recognized in the same tube diameter which are called small and large slugs. Semi-annular flow is observed as an independent pattern in the 70 mm tube that does not behave as known churn or annular patterns.

  14. Acceptance issues for large items and difficult waste

    International Nuclear Information System (INIS)

    Palmer, J.; Lock, Peter

    2002-01-01

    Peter Lock described some particular cases which had given rise to difficult acceptance issues at NIREX, ranging from large size items to the impacts of chemicals used during decontamination on the mobility of radionuclides in a disposal facility: The UK strategy for intermediate level and certain low level radioactive waste disposal is based on production of cementitious waste-forms packaged in a standard range of containers as follows: 500 litre Drum - the normal container for most operational ILW (0.8 m diameter x 1.2 m high); 3 m"3 Box - a larger container for solid wastes (1.72 m x 1.72 m plan x 1.2 m high); 3 m"3 Drum - a larger container for in-drum mixing and immobilisation of sludge waste-forms (1.72 m diameter x 1.2 m high); 4 m Box - for large items of waste, especially from decommissioning (4.0 m x 2.4 m plan x 2.2 m high); 2 m LLW Box - for higher-density wastes (2.0 m x 2.4 m plan x 2.2 m high). In addition the majority of LLW is packaged by supercompaction followed by grouting in modified ISO freight containers (6 m x 2.5 m x 2.5 m). Some wastes do not fit easily into this strategy. These wastes include: very large items, (too big for the 4 m box) which, if dealt with whole, pose transport and disposal problems. These items are discussed further in Section 2; waste whose characteristics make packaging difficult. Such wastes are described in more detail in Section 3

  15. Mechanical behaviors of the dispersion nuclear fuel plates induced by fuel particle swelling and thermal effect II: Effects of variations of the fuel particle diameters

    International Nuclear Information System (INIS)

    Ding Shurong; Wang Qiming; Huo Yongzhong

    2010-01-01

    In order to predict the irradiation mechanical behaviors of plate-type dispersion nuclear fuel elements, the total burnup is divided into two stages: the initial stage and the increasing stage. At the initial stage, the thermal effects induced by the high temperature differences between the operation temperatures and the room temperature are mainly considered; and at the increasing stage, the intense mechanical interactions between the fuel particles and the matrix due to the irradiation swelling of fuel particles are focused on. The large-deformation thermo-elasto-plasticity finite element analysis is performed to evaluate the effects of particle diameters on the in-pile mechanical behaviors of fuel elements. The research results indicate that: (1) the maximum Mises stresses and equivalent plastic strains at the matrix increase with the fuel particle diameters; the effects of particle diameters on the maximum first principal stresses vary with burnup, and the considered case with the largest particle diameter holds the maximum values all along; (2) at the cladding near the interface between the fuel meat and the cladding, the Mises stresses and the first principal stresses undergo major changes with increasing burnup, and different variations exist for different particle diameter cases; (3) the maximum Mises stresses at the fuel particles rise with the particle diameters.

  16. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  17. The design and construction of large diameter pre-filter packed recovery wells at the Ninth Avenue Superfund Site

    International Nuclear Information System (INIS)

    Lombardo, S.L.; Maley, T.J.; Bono, B.A.

    1992-01-01

    Large diameter groundwater/oil recovery wells were installed in an unconfined sand aquifer at the Ninth Avenue Superfund Site in Gary, Indiana. To assure adequate filter packs, prefilter packed groundwater/oil recovery wells were selected to minimize silting by using appropriate screen slot size and filter pack. A properly sized filter pack was necessary to prevent the formation material from entering the well. During field drilling operations, open-quotes having sandsclose quotes and silting of existing wells were encountered. By using sieve analyses of the native aquifer soil, described by Driscoll (1989), the filter pack and screen slot size were selected. Prefilter packed well screens were selected for this site to assure the presence of a uniform filter pack, thus minimizing siltation in the wells. A prefilter packed well screen consists of a double screen with the interstitial space filled with granular filter pack material designed specifically for site conditions. These wells provide the adequate filter pack without the need to add additional filter pack material outside the well screen. Wells were installed using 12 1/4 inch ID hollow stem augers. This methodology is EPA-approved, expeditious, and inexpensive. Level B personal protective equipment was required during installation. Therefore, the advantages of hollow stem drilling include short drilling time and no circulation fluids. The 14 recovery wells were successfully installed in 14 days using the hollow stem auger drilling technique. Observations during well development revealed little or no silt present in purged groundwater

  18. A control study of TACE using high-dosed and routine-dosed iodized oil as a treatment of large hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Zhou Junmin; Zhan Jincheng; Zhang Zhenming

    2005-01-01

    Objective: To investigate the side effects and curative effect in high-dosed lipiodol-transcatheter arterial chemoembolization as a treatment of large hepatocellular carcinoma. Methods: 79 patients with unresectable hepatocellular carcinoma were treated by TACE, and divided into 2 groups. In group A, 39 patients with the tumor sized 7-18cm in diameter, routine-dosed, 10-20ml lipiodol was given in TACE. 40 patients were enrolled in the high-dosed group B, who were given more than 20ml iodized oil in TACE. Results: The First to third year survival rate of group A was 66.7%, 33.3%, 0% respectively,while in group B it was 75%, 45%, 7.5% respectively. The effective rate was 71.7% in Group A and 87.5% in Group B. There was a significant difference between both groups. There was no significant difference of critical side effects and liver function damage between group A and B. Conclusion: High-dosed lipiodol chemoembolization as a treatment of unresectable hepatocellular carcinoma is superior to the routine TACE, especially when the tumor is large and the liver function reserve is good. (authors)

  19. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  20. Database and prediction model for CANDU pressure tube diameter

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.Y.; Park, J.H. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2014-07-01

    The pressure tube (PT) diameter is basic data in evaluating the CCP (critical channel power) of a CANDU reactor. Since the CCP affects the operational margin directly, an accurate prediction of the PT diameter is important to assess the operational margin. However, the PT diameter increases by creep owing to the effects of irradiation by neutron flux, stress, and reactor operating temperatures during the plant service period. Thus, it has been necessary to collect the measured data of the PT diameter and establish a database (DB) and develop a prediction model of PT diameter. Accordingly, in this study, a DB for the measured PT diameter data was established and a neural network (NN) based diameter prediction model was developed. The established DB included not only the measured diameter data but also operating conditions such as the temperature, pressure, flux, and effective full power date. The currently developed NN based diameter prediction model considers only extrinsic variables such as the operating conditions, and will be enhanced to consider the effect of intrinsic variables such as the micro-structure of the PT material. (author)

  1. Implosion measurements in a high voltage, large diameter, medium density theta pinch

    International Nuclear Information System (INIS)

    Henins, I.; Hammel, J.E.; Jarboe, T.E.; Marshall, J.; Sherwood, A.R.

    1975-01-01

    Extensive sets of density measurements were obtained for two preionization levels with other parameters held constant (B = 0.5 T, n 0 = 4.8 x 10 14 cm -3 , E/sub theta/ = 1 kV/cm). The gross features of the implosion are similar in the two cases, but the density front is double-peaked for the higher preionization case. Generally, the particles move ahead of the driving magnetic field front, but some are also within this front. After reaching the axis the imploding plasma is observed to move outward again through the magnetic field in a manner suggesting anomalous transport. The particles stop at the outer radii. The total number of particles increases during the implosion and thereafter remains about constant. (auth)

  2. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system

    International Nuclear Information System (INIS)

    Pang, G.; Beachey, D.J.; O'Brien, P.F.; Rowlands, J.A.

    2002-01-01

    Purpose: To improve an online portal imaging system such that implanted cylindrical gold markers of small diameter (no more than 1.0 mm) can be visualized. These small markers would make the implantation procedure much less traumatic for the patient than the large markers (1.6 mm in diameter), which are usually used today to monitor prostate interfraction motion during radiation therapy. Methods and Materials: Several changes have been made to a mirror-video based online imaging system to improve image quality. First, the conventional camera tube was replaced by an avalanche-multiplication-based video tube. This new camera tube has very high gain at the target such that the camera noise, which is one of the main causes of image degradation of online portal imaging systems, was overcome and effectively eliminated. Second, the conventional linear-accelerator (linac) target was replaced with a low atomic number (low-Z) target such that more diagnostic X-rays are present in the megavoltage X-ray beam. Third, the copper plate buildup layer for the phosphor screen was replaced by a thin plastic layer for detection of the diagnostic X-ray components in the beam generated by the low-Z target. Results: Radiopaque fiducial gold markers of different sizes, i.e., 1.0 mm (diameter) x 5 mm (length) and 0.8 mm (diameter) x 3 mm (length), embedded in an Alderson Rando phantom, can be clearly seen on the images acquired with our improved system. These markers could not be seen on images obtained with any commercial system available in our clinic. Conclusion: This work demonstrates the visibility of small-diameter radiopaque markers with an improved online portal imaging system. These markers can be easily implanted into the prostate and used to monitor the interfraction motion of the prostate

  3. Bloch-wave engineered submicron-diameter quantum-dot micropillars for cavity QED experiments

    DEFF Research Database (Denmark)

    Gregersen, Niels; Lermer, Matthias; Reitzenstein, Stephan

    2013-01-01

    The semiconductor micropillar is attractive for cavity QED experiments. For strong coupling, the figure of merit is proportional to Q/√V, and a design combining a high Q and a low mode volume V is thus desired. However, for the standard submicron diameter design, poor mode matching between the ca...... the cavity and the DBR Bloch mode limits the Q. We present a novel adiabatic design where Bloch-wave engineering is employed to improve the mode matching, allowing the demonstration of a record-high vacuum Rabi splitting of 85 μeV and a Q of 13600 for a 850 nm diameter micropillar....

  4. Determination of the Tapping Part Diameter of the Thread Mill

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2015-01-01

    Full Text Available Currently, there is a tendency to increase the proportion of thread milling operations, among other ways of tapping, which is associated with increasing number of CNC machines, flexibility and versatility of the process.Developments presently existing in the RF and used in the thread mills deal, mainly, with the thread milling cutter designs, to process internal and external thread with straight flutes made from high-speed steel.The paper presents a technique to calculate and select the initial design parameters, i.e. the external diameter of the tapping part of thread milling cutter, which is chosen as a basic computational design. The analysis of directories of tool companies containing foreign de-signs of solid thread end-milling cutters has shown that most of them rep-resent the thread cutter designs made of solid carbide. There are solid and interlocking side milling cutters, which use a tapping part both as a single-disk and as a multi-disk one; chip flutes are made to be both as direct and as screw; solid designs of cutters are made from carbide with a diameter of up to 20 ... 25 mm; thread cutters can be left- and right-hand cutting; Designs of the combined thread mills are proposed; internal channels are used for coolant supply.It is shown that the purpose of the external diameter of the tapping part of the thread mill should take into account the effect of the thread mill diameter on the milling process performance, precision of thread profile received, taper thread, tool strength, and the volume of flutes.The analysis has shown that when choosing the external diameter of the thread mill it worth taking its maximum diameter to improve the char-acteristics of the process under the restrictions imposed on the accuracy of the formed thread.

  5. Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre.

    Science.gov (United States)

    Mirmohammadi, Hesam; Sitarz, Monika; Shemesh, Hagay

    2018-01-01

    Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of their corresponding files at different levels using laser micrometre. Twenty files and corresponding GP master cones of Reciproc R40 (40/0.06) (VDW, Munich, Germany), WaveOne Large(40/0.08)(Dentsply Maillefer, Ballaigues, Switzerland), ProTaper F3 (30/0.09) (Dentsply Maillefer, Ballaigues, Switzerland), and Mtwo 40/0.06 (VDW, Munich, Germany) were examined using laser micrometre (LSM 6000 by Mitutoyo, Japan) with accuracy of 1 nm to establish their actual diameter at D 0 , D 1 , D 3 and D 6 . The data was analysed using the independent t -test. The differences were considered at 0.05. The diameter of GP master cones was significantly larger than that of the corresponding files at all levels in all brands. ProTaper GP diameter was closest to the file diameter at D1 (GP=0.35, File=0.35 mm), and D3 (GP=0.48, File=0.49). Within the same manufacturer, GP cone diameters do not match the diameters of their corresponding files. Clinicians are advised to use a GP gauge to cut the tip so as to appropriate the diameter from a smaller sized GP cone.

  6. Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios

    Science.gov (United States)

    Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh

    2018-03-01

    In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.

  7. Pore diameter control of anodic aluminum oxide with ordered array of nanopores

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Allen; Yang, Yong-Feng [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu, 30013 (China); Hu, Chi-Chang [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu 401 (China); Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China); Lin, Chi-Cheng [Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China)

    2008-01-01

    Highly uniform, self-ordered anodic aluminum oxide (AAO) with an ordered nanoporous array can be effectively formed from industrially pure (99.5%) aluminum sheets through an anodizing program in a mixture solution of sulfuric and oxalic acids. The influences of anodizing variables, such as applied voltage, solution temperature, oxalic acid concentration, agitation rate, and sulfuric acid concentration, on the average pore diameter of AAO were systematically investigated using fractional factorial design (FFD). The applied voltage, and sulfuric acid concentration were found to be the key factors affecting the pore diameter of AAO films in the FFD study. The pore diameter of AAO is regularly increased from ca. 50 to 150 nm when the applied voltage and the concentration of sulfuric acid are gradually increased from 53 to 80 V and from 3.5 to 8 M, respectively. Fine tuning of the pore diameter for AAO films with an ordered, nanoporous, arrayed structure from industrially pure aluminum sheets can be achieved. (author)

  8. Effects of residual stress on fatigue strength of small diameter welded pipe joint

    International Nuclear Information System (INIS)

    Yamashita, Tetsuo; Hattori, Takahiro; Nomoto, Toshiharu; Iida, Kunihiro; Sato, Masanobu

    1996-01-01

    A power plant consists of many welded components, therefore, it is essential in establishing the reliability of the power plant to maintain the reliability of all welded components. The fatigue failure caused by mechanical vibrations of small diameter welded joints, which is represented by socket welded joints, is one of the major causes of trouble for the welded parts of the power plant. Here, bending fatigue tests were conducted to investigate the fatigue strength of small diameter socket welded pipe joints. In the most cases of large diameter socket joints, a fatigue crack started from the root of the fillet weld though the stress amplitude at the root was smaller than that at the toe of fillet weld. Additionally, the fatigue strength was affected by the weld bead sequence. The residual stress was considered to be one of the important parameters governing fatigue strength, therefore, its effects were investigated. In several types of pipe joints, the local stress and residual stress distributions were calculated by finite element analysis. The residual stresses were compressive at the toe and tensile at the root of the socket welded joints. Based on these results, the effects of residual stresses on the fatigue strength are discussed for small diameter welded pipe joints in the present work

  9. Measuring the diameter of rising gas bubbles by means of the ultrasound transit time technique

    Energy Technology Data Exchange (ETDEWEB)

    Richter, T., E-mail: Thomas.Richter6@tu-dresden.de; Eckert, K., E-mail: Kerstin.Eckert@tu-dresden.de; Yang, X.; Odenbach, S.

    2015-09-15

    Highlights: • Ultrasound transit time technique (UTTT) is applied to the zig-zag raise of gas bubble. • Comparison of bubble diameter and tilt, measured by UTTT, with high-speed imaging. • Uncertainty in the determination of the bubble diameter by UTTT is less than 7%. • UTTT is able to measure dynamic changes in bubble size in opaque liquids and vessels. • UTTT can be applied to liquid metal loops. - Abstract: This study presents ultrasound transit time technique (UTTT) measurements of the diameter variations of single argon bubbles rising in a zig-zag trajectory in water. Simultaneous size measurements with a high-speed camera show that UTTT resolves both the apparent diameter and the tilt of the bubble axis with an accuracy of better than 7%. This qualifies UTTT for the measurement of bubble sizes in opaque liquids, such as liquid metals, or vessels.

  10. Multivariate statistics high-dimensional and large-sample approximations

    CERN Document Server

    Fujikoshi, Yasunori; Shimizu, Ryoichi

    2010-01-01

    A comprehensive examination of high-dimensional analysis of multivariate methods and their real-world applications Multivariate Statistics: High-Dimensional and Large-Sample Approximations is the first book of its kind to explore how classical multivariate methods can be revised and used in place of conventional statistical tools. Written by prominent researchers in the field, the book focuses on high-dimensional and large-scale approximations and details the many basic multivariate methods used to achieve high levels of accuracy. The authors begin with a fundamental presentation of the basic

  11. Variable wide range of lens power and its improvement in a liquid-crystal lens using highly resistive films divided into two regions with different diameters

    Science.gov (United States)

    Kawamura, Marenori; Sato, Susumu

    2018-05-01

    The variable range of lens power of a liquid-crystal (LC) lens driven by two voltages is discussed on the basis of calculated and experimental results. The LC lens has two electrodes, which are a circularly hole-patterned electrode and a circular electrode, in addition to a common electrode, and highly resistive transparent films. The variable range of lens power increases with increasing driving voltage applied across the circularly hole-patterned electrode and the common electrode, and with decreasing diameter of highly resistive films. However, the optical-phase retardation profile tends to deviate from a parabolic curve in these cases. As a method to improve the trade-off properties, the highly resistive film is divided into two regions with different diameters, where the sheet resistance of an outer film is larger than that of an inner one. The improved LC lens has a lens power that varies in a wide range, and it exhibits a good parabolic phase retardation profile.

  12. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  13. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  14. Lysosome Transport as a Function of Lysosome Diameter

    Science.gov (United States)

    Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.

    2014-01-01

    Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985

  15. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  16. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-16

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  17. In-situ high resolution particle sampling by large time sequence inertial spectrometry

    International Nuclear Information System (INIS)

    Prodi, V.; Belosi, F.

    1990-09-01

    In situ sampling is always preferred, when possible, because of the artifacts that can arise when the aerosol has to flow through long sampling lines. On the other hand, the amount of possible losses can be calculated with some confidence only when the size distribution can be measured with a sufficient precision and the losses are not too large. This makes it desirable to sample directly in the vicinity of the aerosol source or containment. High temperature sampling devices with a detailed aerodynamic separation are extremely useful to this purpose. Several measurements are possible with the inertial spectrometer (INSPEC), but not with cascade impactors or cyclones. INSPEC - INertial SPECtrometer - has been conceived to measure the size distribution of aerosols by separating the particles while airborne according to their size and collecting them on a filter. It consists of a channel of rectangular cross-section with a 90 degree bend. Clean air is drawn through the channel, with a thin aerosol sheath injected close to the inner wall. Due to the bend, the particles are separated according to their size, leaving the original streamline by a distance which is a function of particle inertia and resistance, i.e. of aerodynamic diameter. The filter collects all the particles of the same aerodynamic size at the same distance from the inlet, in a continuous distribution. INSPEC particle separation at high temperature (up to 800 C) has been tested with Zirconia particles as calibration aerosols. The feasibility study has been concerned with resolution and time sequence sampling capabilities under high temperature (700 C)

  18. Simultaneous correction of large low-order and high-order aberrations with a new deformable mirror technology

    Science.gov (United States)

    Rooms, F.; Camet, S.; Curis, J. F.

    2010-02-01

    A new technology of deformable mirror will be presented. Based on magnetic actuators, these deformable mirrors feature record strokes (more than +/- 45μm of astigmatism and focus correction) with an optimized temporal behavior. Furthermore, the development has been made in order to have a large density of actuators within a small clear aperture (typically 52 actuators within a diameter of 9.0mm). We will present the key benefits of this technology for vision science: simultaneous correction of low and high order aberrations, AO-SLO image without artifacts due to the membrane vibration, optimized control, etc. Using recent papers published by Doble, Thibos and Miller, we show the performances that can be achieved by various configurations using statistical approach. The typical distribution of wavefront aberrations (both the low order aberration (LOA) and high order aberration (HOA)) have been computed and the correction applied by the mirror. We compare two configurations of deformable mirrors (52 and 97 actuators) and highlight the influence of the number of actuators on the fitting error, the photon noise error and the effective bandwidth of correction.

  19. Tracheomalacia Treatment Using a Large-Diameter, Custom-Made Airway Stent in a Case with Mounier-Kuhn Syndrome

    OpenAIRE

    Özdemir, Cengiz; Sökücü, Sinem Nedime; Karasulu, Levent; Altın, Sedat; Dalar, Levent

    2014-01-01

    Mounier-Kuhn Syndrome (MKS) is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and tha...

  20. Recent quality of ultra large rotor shafts

    International Nuclear Information System (INIS)

    Suzuki, Akira; Kinoshita, Shushi; Morita, Kikuo; Kikuchi, Hideo; Takada, Masayoshi

    1983-01-01

    Large size and high quality are required for rotor shafts accompanying recent trend of thermal and nuclear power generation toward large capacity. As for the low pressure rotor shafts for large capacity turbines, the disks and a shaft tend to be made into one body instead of conventional shrink fit construction, because of the experience of rotor accidents and the improvement of reliability. Therefore the ingots required become more and more large, and excellent production techniques are required for steel making, forging and heat treatment. Kobe Steel Ltd. have made about 20 large generator shafts from 420 t and 500 t ingots, and confirmed their stable high quality. Also a one-body low pressure rotor of 2600 mm diameter was made for trial, and its quality was examined. It was confirmed that the effect of forging and heat treatment was given sufficiently, and the production techniques for super-large one-body rotors were established. In steel making, vacuum degassing was applied twice to decrease hydrogen content, and VV restriction forging and pre-stage treatment were carried out. The properties of large rotors are reported. (Kako, I.)

  1. Development of Bubble Lift-off Diameter Model for Subcooled Boiling Flows

    International Nuclear Information System (INIS)

    Hoang, Nhan Hien; Chu, Incheol; Song Chulhwa; Euh, Dongjin

    2014-01-01

    A lot of models and correlations for predicting the bubble departure/lift-off diameter are available in the literature. Most of them were developed based on a hydrodynamic principle, which balances forces acting on a bubble at the departure/lift-off point. One difficulty of these models is lack of essential information, such as bubble front velocity, liquid velocity, or relative velocity, to estimate the active force elements. Hence, the lift-off bubble diameter predicted by these hydrodynamic-controlled models may be suffered a large uncertainty. In contract to the hydrodynamic approach, there are few models developed based on the heat transfer aspect. By balancing the heat conducted through a microlayer underneath a bubble with the heat taken away by condensation at the upper part of the bubble, Unal derived a heat-controlled model of the bubble lift-off diameter. This model did not consider the role of superheat liquid layer surrounding the bubble as well as the effect of liquid properties on the heat transfer process. Beside these two approaches, several empirical correlations have been proposed based on dimensionless analyses for measured experimental databases. The application of these correlations to different experiments conditions is, of course, questionable because of the lack of physical bases. Regarding the heat transfer accompanied by a vapor bubble, four involved heat transfer regions surrounding this bubble can be defined as in Fig. 1. These are dry region, microlayer, superheated liquid layer (SpLL) and subcooled liquid layer (SbLL). The existing of the microlayer is confirmed by experiments, and it is considered to be very effective in the heat transfer. Sernas and Hoper defined five types of the microlayer and indicated that the microlayer acting as a very thick liquid layer gives a best prediction for the bubble growth. However, beside the microlayer, the SpLL might play an important role in the heat transfer if its effective heat transfer area

  2. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    Science.gov (United States)

    Dekker, K. H.; Battista, J. J.; Jordan, K. J.

    2017-05-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.

  3. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    International Nuclear Information System (INIS)

    Dekker, K H; Battista, J J; Jordan, K J

    2017-01-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations. (paper)

  4. PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS

    Energy Technology Data Exchange (ETDEWEB)

    Yu Daren; Xie Zongxia; Hu Qinghua [Harbin Institute of Technology, Harbin 150001 (China); Yang Shuhong; Zhang Jun; Wang Jingxiu, E-mail: caddiexie@hotmail.com, E-mail: zjun@ourstar.bao.ac.cn [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2011-12-10

    The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in the five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I

  5. 1998 Annual Study Report. Standardization of methods for evaluating characteristics of high-strength, large-diameter steel pipes for superhigh-pressure natural gas pipelines; 1998 nendo seika hokokusho. Chokoatsu tennen gas pipeline yo kokyodo daikei kokan no tokusei hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The pipelines for safely transmitting superhigh-pressure natural gas should have excellent characteristics. The steel pipe is required to have a sufficient toughness, more concretely Charpy impact-absorbing energy, to prevent propagating shear fracture characteristic of natural gas pipelines. Recently, the natural gas pipeline is increasingly required to have higher design pressures (15 Mpa or higher) and grade (X80 or higher). In order to develop the techniques for simulating crack propagation in the propagating shear fracture of natural gas pipe lines as part of the programs to cope with these trends, the 1998 efforts were directed to reviewing the research results obtained so far and analysis of the problems to be solved and tasks to be taken, based on which the analytical procedure for gas releasing phenomena during the fracture process was basically developed, the material characteristic data were collected by the laboratory scale toughness tests, and the preliminary tests with rupture disks were conducted to verify the above analytical procedure. These efforts have established the bases for evaluating the characteristics of high-strength, large-diameter steel pipes in the light of safety against fracture, and greatly advanced the program towards the final target of developing the international specification drafts for toughness. (NEDO)

  6. Experimental study of high-performance cooling system pipeline diameter and working fluid amount

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan; Hrabovsky, Peter; Papučík, Štefan

    2016-03-01

    This work deals with heat transfer resulting from the operation of power electronic components. Heat is removed from the mounting plate, which is the evaporator of the loop thermosyphon to the condenser and by natural convection is transferred to ambient. This work includes proposal of cooling device - loop thermosyphon, with its construct and follow optimization of cooling effect. Optimization proceeds by selecting the quantity of working fluid and selection of diameters vapour line and liquid line of loop thermosyphon.

  7. Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots.

    Science.gov (United States)

    Beaufrère, Hugues; Rodriguez, Daniel; Pariaut, Romain; Gaschen Dvm, Lorrie; Schnellbacher, Rodney; Nevarez, Javier G; Tully, Thomas N

    2011-02-01

    To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. 13 Hispaniolan Amazon parrots (Amazona ventralis). 16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

  8. Historical perspective on diameter-limit cutting in northeastern forests

    Science.gov (United States)

    Matthew J. Kelty; Anthony W. D' Amato; Anthony W. D' Amato

    2006-01-01

    The use of diameter-limit cutting and high-grading is currently a concern for long-term sustainability of forests in the Northeastern United States and surrounding areas. This paper reviews historical information about the kinds of harvesting used in this region from 1620 to 1950, to provide a context for current discussions. Throughout this period, most timber...

  9. Design of large aperture, low mass vacuum windows

    International Nuclear Information System (INIS)

    Leonhardt, W.J.; Mapes, M.

    1993-01-01

    Large vacuum vessels are employed downstream of fixed targets in High Energy Physics experiments to provide a long path for particles to traverse without interacting with air molecules. These vessels generally have a large aperture opening known as a vacuum window which employs a thin membrane to preserve the vacuum environment yet allows the particles to pass through with a minimal effect on them. Several large windows have been built using a composite of Kevlar/Mylar including circular windows to a diameter of 96.5 cm and rectangular windows up to 193 cm x 86 cm. This paper describes the design, fabrication, testing and operating experience with these windows and relates the actual performance to theoretical predictions

  10. An in-pipe mobile micromachine using fluid power. A mechanism adaptable to pipe diameters

    International Nuclear Information System (INIS)

    Yoshida, Kazuhiro; Yokota, Shinichi; Takahashi, Ken

    2000-01-01

    To realize micro maintenance robots for small diameter pipes of nuclear reactors and so on, high power in-pipe mobile micromachines have been required. The authors have proposed the bellows microactuator using fluid power and have tried to apply the actuators to in-pipe mobile micromachines. In the previous papers, some inchworm mobile machine prototypes with 25 mm in diameter are fabricated and the traveling performances are experimentally investigated. In this paper, to miniaturize the in-pipe mobile machine and to make it adaptable to pipe diameters, firstly, a simple rubber-tube actuator constrained with a coil-spring is proposed and the static characteristics are investigated. Secondly, a supporting mechanism which utilizes a toggle mechanism and is adaptable to pipe diameters is proposed and the supporting forces are investigated. Finally, an in-pipe mobile micromachine for pipe with 4 - 5 mm in diameter is fabricated and the maximum traveling velocity of 7 mm/s in both ahead and astern movements is experimentally verified. (author)

  11. Packing configuration performance for small stem diameters

    International Nuclear Information System (INIS)

    Aikin, J.A.; Spence, C.G.; Cumming, D.

    1997-01-01

    The extensive use of graphite packing and its excellent track record for large isolating valves in CANDU, Primary Heat Transfer (PHT) systems has resulted in an increased application of graphite packing on the conventional side. Many of these applications are in air operated valves (AOVs) where the packing sets are used on small stem diameters (<1 inch) with frequent short-cycling strokes (± 10% of full stroke). The direct application of the proven packing configurations for large isolated valves to control valve application has generated problems such as stiction, packing wear and, in isolated cases, stem stall. To address this issue, a test program was conducted at AECL, CRL by MED branch. The testing showed that by reconfiguring the packing sets and using PTFE wafers reductions in stem friction of 50% at ambient conditions, a 3 fold at hot conditions are achievable. The test program also demonstrated benefits gained in packing wear with different stem roughness finishes and the potential need to exercise small stems valves that see less than full stroke cycling. The paper describes the tests results and provides field support experience. (author)

  12. Fabrication and Characterization of Single Phase α-Alumina Membranes with Tunable Pore Diameters

    Science.gov (United States)

    Masuda, Tatsuya; Asoh, Hidetaka; Haraguchi, Satoshi; Ono, Sachiko

    2015-01-01

    Nanoporous and single phase α-alumina membranes with pore diameters tunable over a wide range of approximately 60–350 nm were successfully fabricated by optimizing the conditions for anodizing, subsequent detachment, and heat treatment. The pore diameter increased and the cell diameter shrunk upon crystallization to α-alumina by approximately 20% and 3%, respectively, in accordance with the 23% volume shrinkage resulting from the change in density associated with the transformation from the amorphous state to α-alumina. Nevertheless, flat α-alumina membranes, each with a diameter of 25 mm and a thickness of 50 μm, were obtained without thermal deformation. The α-alumina membranes exhibited high chemical resistance in various concentrated acidic and alkaline solutions as well as when exposed to high temperature steam under pressure. The Young’s modulus and hardness of the single phase α-alumina membranes formed by heat treatment at 1250 °C were notably decreased compared to the corresponding amorphous membranes, presumably because of the nodular crystallite structure of the cell walls and the substantial increase in porosity. Furthermore, when used for filtration, the α-alumina membrane exhibited a level of flux higher than that of the commercial ceramic membrane. PMID:28788005

  13. Fabrication and Characterization of Single Phase α-Alumina Membranes with Tunable Pore Diameters

    Directory of Open Access Journals (Sweden)

    Tatsuya Masuda

    2015-03-01

    Full Text Available Nanoporous and single phase α-alumina membranes with pore diameters tunable over a wide range of approximately 60–350 nm were successfully fabricated by optimizing the conditions for anodizing, subsequent detachment, and heat treatment. The pore diameter increased and the cell diameter shrunk upon crystallization to α-alumina by approximately 20% and 3%, respectively, in accordance with the 23% volume shrinkage resulting from the change in density associated with the transformation from the amorphous state to α-alumina. Nevertheless, flat α-alumina membranes, each with a diameter of 25 mm and a thickness of 50 μm, were obtained without thermal deformation. The α-alumina membranes exhibited high chemical resistance in various concentrated acidic and alkaline solutions as well as when exposed to high temperature steam under pressure. The Young’s modulus and hardness of the single phase α-alumina membranes formed by heat treatment at 1250 °C were notably decreased compared to the corresponding amorphous membranes, presumably because of the nodular crystallite structure of the cell walls and the substantial increase in porosity. Furthermore, when used for filtration, the α-alumina membrane exhibited a level of flux higher than that of the commercial ceramic membrane.

  14. Critical heat flux measurements in small-diameter tubes using R12 as model fluid

    International Nuclear Information System (INIS)

    Mueller-Menzel, T.

    1987-01-01

    Results of critical heat flux measurements are reported for vertical upflow of Refrigerant 12 at high mass fluxes and high pressures in small diameter tubes. The data are transformed into water data using a scaling law, which is verified by means of a new analysis. An error estimation includes the error of the scaling law. Special phenomena ('limiting quality', 'upstream boiling crisis') are explained by theoretical models. The applicability of existing correlations is checked and a new CHF-table for small diameter tubes is presented. With 41 figs., 12 tabs [de

  15. Dynamic response of the U-tube liquid manometer with equal diameter columns

    International Nuclear Information System (INIS)

    Zahariea, D

    2010-01-01

    The paper presents numerical solving methods using MATLAB programming language of the governing equation of the liquid oscillations in a U-tube liquid manometer with equal diameter columns. Assuming some numerical values for geometrical and functional parameters of this pressure measurement system, the dynamic behavior of the oscillating system will be analyzed using four MATLAB based computational methods: the method of the default MATLAB procedures, the Simulink method, the Simscape method and the method of the Control System Toolbox procedures. According to all these methods, in almost all the cases analyzed, the dynamic behavior of the U-tube liquid manometer with equal diameter columns corresponds to an under-damped dynamic system. The influence of some important constructive and functional parameters (the columns diameter, the manometer liquid, the capillarity action and the connection tube between the reservoir and the manometer) has been investigated. Improving the dynamic response (decreasing the overshoot and the settling time, increasing the phase and delay margins) can be achieved by increasing the connection tube length, by decreasing the columns diameter and by using a high density liquid manometer.

  16. Estimating air drying times of small-diameter ponderosa pine and Douglas-fir logs.

    Science.gov (United States)

    William T. Simpson; Xiping. Wang

    2003-01-01

    Because dense stands of softwood trees are causing forest health problems in the western United States, new ways to use this material need to be found. One option is to use this material as logs rather than sawing it into lumber. For many applications, logs require some degree of drying. Even though these logs may be considered small diameter, they are large compared...

  17. Production and cost of harvesting, processing, and transporting small-diameter (< 5 inches) trees for energy

    Science.gov (United States)

    Fei Pan; Han-Sup Han; Leonard R. Johnson; William J. Elliot

    2008-01-01

    Dense, small-diameter stands generally require thinning from below to improve fire-tolerance. The resulting forest biomass can be used for energy production. The cost of harvesting, processing, and transporting small-diameter trees often exceeds revenues due to high costs associated with harvesting and transportation and low market values for forest biomass....

  18. High pressure fiber optic sensor system

    Science.gov (United States)

    Guida, Renato; Xia, Hua; Lee, Boon K; Dekate, Sachin N

    2013-11-26

    The present application provides a fiber optic sensor system. The fiber optic sensor system may include a small diameter bellows, a large diameter bellows, and a fiber optic pressure sensor attached to the small diameter bellows. Contraction of the large diameter bellows under an applied pressure may cause the small diameter bellows to expand such that the fiber optic pressure sensor may measure the applied pressure.

  19. Normal ureteral diameter in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oden, A.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg; Goeteborg Univ.

    1985-01-01

    Ureteral diameters were estimated on films from intravenous urography in 194 children (100 boys and 94 girls) aged 0-16 years. Children with signs of urinary tract infection, calculi, obstruction, duplication or malformation were excluded. Films obtained without abdominal compression were used for measurements, including only ureters visualized over 50 per cent of their lengths. A good correlation was demonstrated between ureteral diameter and age and between ureteral diameter and the length of a segment of the lumbar spine. The widest part of the ureter was most often located just above the crossing of the iliac vessels. The right ureter was slightly wider than the left one. No difference between boys and girls was noted. The results are in good agreement with those of others obtained at autopsy. Bearing in mind the possible physiologic variations, it would seem that measuring the ureteral diameter can be of value for a more objective differentiation between dilated and non-dilated ureters. (orig.)

  20. A new large-scale plasma source with plasma cathode

    International Nuclear Information System (INIS)

    Yamauchi, K.; Hirokawa, K.; Suzuki, H.; Satake, T.

    1996-01-01

    A new large-scale plasma source (200 mm diameter) with a plasma cathode has been investigated. The plasma has a good spatial uniformity, operates at low electron temperature, and is highly ionized under relatively low gas pressure of about 10 -4 Torr. The plasma source consists of a plasma chamber and a plasma cathode generator. The plasma chamber has an anode which is 200 mm in diameter, 150 mm in length, is made of 304 stainless steel, and acts as a plasma expansion cup. A filament-cathode-like plasma ''plasma cathode'' is placed on the central axis of this source. To improve the plasma spatial uniformity in the plasma chamber, a disk-shaped, floating electrode is placed between the plasma chamber and the plasma cathode. The 200 mm diameter plasma is measure by using Langmuir probes. As a result, the discharge voltage is relatively low (30-120 V), the plasma space potential is almost equal to the discharge voltage and can be easily controlled, the electron temperature is several electron volts, the plasma density is about 10 10 cm -3 , and the plasma density is about 10% variance in over a 100 mm diameter. (Author)

  1. Transition to a new generation of large natural-draught cooling towers

    International Nuclear Information System (INIS)

    Biller, H.; Boslau, C.; Heyde, K.; Kockelke, W.

    1985-01-01

    A concept of a new generation of natural-draught cooling towers for large nuclear power plant units is presented considering optimization and calculation methods, safety philosophy, dimension criteria, constructional measures, building materials, construction surveying, climbing formwork, and climbing cranes. The first installation will be available by 1990, with a unit 250 m in diameter by 150 m high

  2. Small-Diameter Awls Improve Articular Cartilage Repair After Microfracture Treatment in a Translational Animal Model.

    Science.gov (United States)

    Orth, Patrick; Duffner, Julia; Zurakowski, David; Cucchiarini, Magali; Madry, Henning

    2016-01-01

    Microfracture is the most commonly applied arthroscopic marrow stimulation procedure. Articular cartilage repair is improved when the subchondral bone is perforated by small-diameter microfracture awls compared with larger awls. Controlled laboratory study. Standardized rectangular (4 × 8 mm) full-thickness chondral defects (N = 24) were created in the medial femoral condyle of 16 adult sheep and debrided down to the subchondral bone plate. Three treatment groups (n = 8 defects each) were tested: 6 microfracture perforations using small-diameter awls (1.0 mm; group 1), large-diameter awls (1.2 mm; group 2), or without perforations (debridement control; group 3). Osteochondral repair was assessed at 6 months in vivo using established macroscopic, histological, immunohistochemical, biochemical, and micro-computed tomography analyses. Compared with control defects, histological cartilage repair was always improved after both microfracture techniques (P Subchondral bone cysts and intralesional osteophytes were frequently observed after either microfracture treatment. Macroscopic grading, DNA, proteoglycan, and type I and type II collagen contents as well as degenerative changes within the adjacent cartilage remained unaffected by the awl diameter. Small-diameter microfracture awls improve articular cartilage repair in the translational sheep model more effectively than do larger awls. These data support the use of small microfracture instruments for the surgical treatment of cartilage defects and warrant prolonged clinical investigations. © 2015 The Author(s).

  3. Diameter growth performance of tree functional groups in Puerto Rican secondary tropical forests

    Directory of Open Access Journals (Sweden)

    Patricia Adame

    2014-04-01

    Full Text Available Aim of study: Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Yet, the high species diversity of mixed tropical forests, including many uncommon species, hinders the development of species-specific diameter growth models.Area of study: In these analyses, we grouped 82 species from secondary forests distributed across 93 permanent plots on the island of Puerto Rico.Material and Methods: Species were classified according to regeneration strategy and adult height into six functional groups. This classification allowed us to develop a robust diameter growth model using growth data collected from 1980-1990. We used mixed linear model regression to analyze tree diameter growth as a function of individual tree characteristics, stand structure, functional group and site factors.Main results: The proportion of variance in diameter growth explained by the model was 15.1%, ranging from 7.9 to 21.7%. Diameter at breast height, stem density and functional group were the most important predictors of tree growth in Puerto Rican secondary forest. Site factors such as soil and topography failed to predict diameter growth.Keywords: Caribbean forests; growth model; tropical forest succession; Puerto Rico.

  4. Cross-sectional imaging of large and dense materials by high energy X-ray CT using linear accelerator

    International Nuclear Information System (INIS)

    Kanamori, Takahiro; Kamata, Shouji; Ito, Shinichi.

    1989-01-01

    A prototype high energy X-ray CT (computed tomography) system has been developed which employs a linear accelerator as the X-ray source (max. photon energy: 12 MeV). One problem encountered in development of this CT system was to reduce the scattered photons from adjacent detectors, i.e. crosstalk, due to high energy X-rays. This crosstalk was reduced to 2% by means of detector shields using tungsten spacers. Spatial resolution was not affected by such small crosstalk as confirmed by numerical simulations. A second problem was to reduce the scattered photons from the test object. This was done using collimators. A third concern was to realize a wide dynamic range data processing which would allow applications to large and dense objects. This problem was solved by using a sample and hold data acquisition method to reduce the dark current of the photo detectors. The dynamic range of this system was experimentally confirmed over 60 dB. It was demonstrated that slits (width: 2 mm) in an iron object (diameter: 25 cm) could be imaged by this prototype CT system. (author)

  5. Highly Flexible and High-Performance Complementary Inverters of Large-Area Transition Metal Dichalcogenide Monolayers

    KAUST Repository

    Pu, Jiang

    2016-03-23

    Complementary inverters constructed from large-area monolayers of WSe2 and MoS2 achieve excellent logic swings and yield an extremely high gain, large total noise margin, low power consumption, and good switching speed. Moreover, the WSe2 complementary-like inverters built on plastic substrates exhibit high mechanical stability. The results provide a path toward large-area flexible electronics. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Spatial characteristics of tree diameter distributions in a temperate old-growth forest.

    Science.gov (United States)

    Zhang, Chunyu; Wei, Yanbo; Zhao, Xiuhai; von Gadow, Klaus

    2013-01-01

    This contribution identifies spatial characteristics of tree diameter in a temperate forest in north-eastern China, based on a fully censused observational study area covering 500×600 m. Mark correlation analysis with three null hypothesis models was used to determine departure from expectations at different neighborhood distances. Tree positions are clumped at all investigated scales in all 37 studied species, while the diameters of most species are spatially negatively correlated, especially at short distances. Interestingly, all three cases showing short-distance attraction of dbh marks are associated with light-demanding shrub species. The short-distance attraction of dbh marks indicates spatially aggregated cohorts of stems of similar size. The percentage of species showing significant dbh suppression peaked at a 4 m distance under the heterogeneous Poisson model. At scales exceeding the peak distance, the percentage of species showing significant dbh suppression decreases sharply with increasing distances. The evidence from this large observational study shows that some of the variation of the spatial characteristics of tree diameters is related variations of topography and soil chemistry. However, an obvious interpretation of this result is still lacking. Thus, removing competitors surrounding the target trees is an effective way to avoid neighboring competition effects reducing the growth of valuable target trees in forest management practice.

  7. Thy1.2 YFP-16 transgenic mouse labels a subset of large-diameter sensory neurons that lack TRPV1 expression.

    Directory of Open Access Journals (Sweden)

    Thomas E Taylor-Clark

    Full Text Available The Thy1.2 YFP-16 mouse expresses yellow fluorescent protein (YFP in specific subsets of peripheral and central neurons. The original characterization of this model suggested that YFP was expressed in all sensory neurons, and this model has been subsequently used to study sensory nerve structure and function. Here, we have characterized the expression of YFP in the sensory ganglia (DRG, trigeminal and vagal of the Thy1.2 YFP-16 mouse, using biochemical, functional and anatomical analyses. Despite previous reports, we found that YFP was only expressed in approximately half of DRG and trigeminal neurons and less than 10% of vagal neurons. YFP-expression was only found in medium and large-diameter neurons that expressed neurofilament but not TRPV1. YFP-expressing neurons failed to respond to selective agonists for TRPV1, P2X(2/3 and TRPM8 channels in Ca2+ imaging assays. Confocal analysis of glabrous skin, hairy skin of the back and ear and skeletal muscle indicated that YFP was expressed in some peripheral terminals with structures consistent with their presumed non-nociceptive nature. In summary, the Thy1.2 YFP-16 mouse expresses robust YFP expression in only a subset of sensory neurons. But this mouse model is not suitable for the study of nociceptive nerves or the function of such nerves in pain and neuropathies.

  8. Spectroscopic study of the diameter distribution of B-doped single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Soria, G.; Pichler, T.; Ayala, P. [University of Vienna, Faculty of Physics, 1090 Vienna (Austria); Daothong, S. [Chiang Mai University, Faculty of Science, 50200 Chiang Mai (Thailand)

    2012-12-15

    In this paper, we report on the diameter distribution of boron-doped single-walled carbon nanotubes grown from triethyl borate with high vacuum chemical vapor deposition, using multi-frequency Raman resonance spectroscopy. The nanotube yield is higher than in previously reported material produced with the same method. Our results suggest that the amount of as-grown material and the range of diameters are directly correlated with feedstock used in the synthesis. The I{sub D}/I{sub G} ratio shows that the morphology of the samples is critically affected by the temperature. The population of diameters in the optimal conditions shows a Poisson distribution with a mean value at {proportional_to}1.15 nm. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. High-Temperature-Short-Time Annealing Process for High-Performance Large-Area Perovskite Solar Cells.

    Science.gov (United States)

    Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk

    2017-06-27

    Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.

  10. Variations the diameter tip of electrode on the resistance spot welding using electrode Cu on worksheet Fe

    Science.gov (United States)

    Baskoro, A. S.; Sugeng, S.; Sifa, Agus; Badruzzaman; Endramawan, Tito

    2018-04-01

    Resistance Spot Weld (RSW) is a welding technology which plays an important role that is often used in industry in large manufacturing industries, especially in the automotive sector, some of the parameters are affecting the welding process that give impact in the weld quality, diameter tip important impact on the resistance spot welding, This study can be categorized as experimental study by using Electrode material such as Cu and Fe Worksheet Materials, with a material thickness of 1 mm,0,8 mm, and 0,6 mm on each worksheet, and the large diameter of tip electrode (5√t) depend on the thickness of worksheet. Testing the material in the electrode and the worksheet by testing the composition and tensile test, and the hardness of the material used are to know the material used certainly. The result of the welding process was done by using the parameters voltage of 8KV, with a duty cycle of 50% using a variation of the time 8s-10s, and variations the electrode tip diameter that are affected by the thickness of the worksheet 5\\sqrt{t}, plate thickness used 1 mm, 0,8 mm and 0,6 mm, so that the electrodes was used to a thickness of 1 mm diameter tip electrode 5 mm, thickness 0,8 mm with an electrode tip diameter 4,5 mm and a thickness 0,6 mm with an electrode diameter of 4 mm, with current welding parameter 8kVA, and variations in holding time 10s, 9s and 8s 50% duty cycle, then testing welds with the standard shear test refers ASTM A370-2012 with more results to a thickness of 0,6 has the ability to withstand greater load on the holding time 8s and 9s, 10s, to a thickness 0,8 mm and 1 mm shear test results demonstrate the ability to withstand loads on the holding time of 10s and 9s have a greater ability than 8s on worksheet that has thickness 1 mm at a holding time of 10s, and then Maximum shear test averaging of 36,41 N at a worksheet with a thickness of 0,8 mm (diameter tip 4,5 mm) at a holding time of 8s and a mean minimum shear stress of 23,73 N at worksheet that

  11. Base metal thermocouples drift rate dependence from thermoelement diameter

    Science.gov (United States)

    Pavlasek, P.; Duris, S.; Palencar, R.

    2015-02-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  12. Base metal thermocouples drift rate dependence from thermoelement diameter

    International Nuclear Information System (INIS)

    Pavlasek, P; Duris, S; Palencar, R

    2015-01-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  13. Design of large aperture, low mass vacuum windows

    International Nuclear Information System (INIS)

    Leonhardt, W.J.; Mapes, M.

    1993-01-01

    Large vacuum vessels are employed downstream of fixed targets in High Energy Physics experiments to provide a long path for particles to transverse without interacting with air molecules. These vessels generally have a large aperture opening known as a open-quotes vacuum windowclose quotes which employs a thin membrane to preserve the vacuum environment yet allows the particles to pass through with a minimal effect on them. Several large windows have been built using a composite of Kevlar/Mylar including circular windows to a diameter of 96.5 cm and rectangular windows up to 193 cm x 86 cm. This paper describes the design, fabrication, testing and operating experience with these windows and relates the actual performance to theoretical predictions

  14. Effective temperatures, angular diameters, distances and linear radii for 160 O and B stars

    International Nuclear Information System (INIS)

    Underhill, A.B.; Divan, L.; Prevot-Burnichon, M.L.; Doazan, V.

    1979-01-01

    The significance is explained of the effective temperatures, angular diameters, distances and linear diameters which have been found from published ultraviolet spectrophotometry, visible and near infrared intermediate-band photometry and model-atmosphere fluxes for 160 O and B stars using a method which is fully explained and evaluated in the full paper which is reproduced on Microfiche MN 189/1. An appendix to the full paper presents BCD spectrophotometry for 77 of the program stars. The angular diameters are systematically the same as those measured previously, and the flux effective temperatures of the main-sequence and giant stars reproduce well the relationship established by other authors, for main-sequence and giant O and B stars. The O8 - B9 supergiants have systematically lower temperatures than do main-sequence stars of the same subtype. The Beta Cephei stars and most Be stars have the same effective temperature as normal stars of the same spectral type. The radii of O and B stars increase from main-sequence to supergiant. The late B supergiants are about twice as large as the O9 supergiants. (author)

  15. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  16. Facile Large-scale synthesis of stable CuO nanoparticles

    Science.gov (United States)

    Nazari, P.; Abdollahi-Nejand, B.; Eskandari, M.; Kohnehpoushi, S.

    2018-04-01

    In this work, a novel approach in synthesizing the CuO nanoparticles was introduced. A sequential corrosion and detaching was proposed in the growth and dispersion of CuO nanoparticles in the optimum pH value of eight. The produced CuO nanoparticles showed six nm (±2 nm) in diameter and spherical feather with a high crystallinity and uniformity in size. In this method, a large-scale production of CuO nanoparticles (120 grams in an experimental batch) from Cu micro-particles was achieved which may met the market criteria for large-scale production of CuO nanoparticles.

  17. Model Test Research on the End Bearing Behavior of the Large-Diameter Cast-in-Place Concrete Pile for Jointed Rock Mass

    Directory of Open Access Journals (Sweden)

    Jingwei Cai

    2016-01-01

    Full Text Available For large-diameter, cast-in-place concrete piles, the end bearing capacity of a single pile is affected by discontinuous surfaces that exist in natural rock masses when the bearing layer of the pile end is located in the rock layer. In order to study the influence of the jointed dip angle on the bearing characteristics of the pile end, the discrete element models are adopted to simulate the mechanical characteristics of the jointed rock masses, and the model tests of the failure mode of the jointed rock masses were also designed. The results of the numerical calculations and modeling tests show that the joints, which have a filtering effect on the internal stress of the bedrock located at the pile end, change the load transferring paths. And the failure mode of the jointed rock foundation also changes as jointed dip angle changes. The rock located at the pile end generally presents a wedge failure mode. In addition, the Q-S curves obtained by model tests show that the ultimate end bearing capacity of a single pile is influenced by the jointed dip angle. The above results provide an important theoretical basis for how to correctly calculate end resistance for a cast-in-place concrete pile.

  18. Measuring Electrospun Nanofibre Diameter: a Novel Approach

    International Nuclear Information System (INIS)

    Ziabari, M.; Mottaghitalab, V.; Haghi, A. K.; McGovern, S. T.

    2008-01-01

    A new method based on image analysis for electrospun nanofibre diameter measurement is presented. First, the SEM micrograph of the nanofibre web obtained by electrospinning process is converted to binary image using local thresholding method. In the next step, skeleton and distance transformed image are generated. Then, the intersection points which bring about untrue measurements are identified and removed from the skeleton. Finally, the resulting skeleton and distance transformed image are used to determine fibre diameter. The method is evaluated by a simulated image with known characteristics generated by ?-randomness procedure. The results indicate that this approach is successful in making fast, accurate automated measurements of electrospun fibre diameters. (cross-disciplinary physics and related areas of science and technology)

  19. Large-area high-power VCSEL pump arrays optimized for high-energy lasers

    Science.gov (United States)

    Wang, Chad; Geske, Jonathan; Garrett, Henry; Cardellino, Terri; Talantov, Fedor; Berdin, Glen; Millenheft, David; Renner, Daniel; Klemer, Daniel

    2012-06-01

    Practical, large-area, high-power diode pumps for one micron (Nd, Yb) as well as eye-safer wavelengths (Er, Tm, Ho) are critical to the success of any high energy diode pumped solid state laser. Diode efficiency, brightness, availability and cost will determine how realizable a fielded high energy diode pumped solid state laser will be. 2-D Vertical-Cavity Surface-Emitting Laser (VCSEL) arrays are uniquely positioned to meet these requirements because of their unique properties, such as low divergence circular output beams, reduced wavelength drift with temperature, scalability to large 2-D arrays through low-cost and high-volume semiconductor photolithographic processes, high reliability, no catastrophic optical damage failure, and radiation and vacuum operation tolerance. Data will be presented on the status of FLIR-EOC's VCSEL pump arrays. Analysis of the key aspects of electrical, thermal and mechanical design that are critical to the design of a VCSEL pump array to achieve high power efficient array performance will be presented.

  20. Estimation of Scatterer Diameter by Normalized Power Spectrum of High-Frequency Ultrasonic RF Echo for Assessment of Red Blood Cell Aggregation

    Science.gov (United States)

    Fukushima, Taku; Hasegawa, Hideyuki; Kanai, Hiroshi

    2011-07-01

    Red blood cell (RBC) aggregation, as one of the determinants of blood viscosity, plays an important role in blood rheology, including the condition of blood. RBC aggregation is induced by the adhesion of RBCs when the electrostatic repulsion between RBCs weakens owing to increases in protein and saturated fatty acid levels in blood, excessive RBC aggregation leads to various circulatory diseases. This study was conducted to establish a noninvasive quantitative method for assessment of RBC aggregation. The power spectrum of ultrasonic RF echoes from nonaggregating RBCs, which shows the frequency property of scattering, exhibits Rayleigh behavior. On the other hand, ultrasonic RF echoes from aggregating RBCs contain the components of reflection, which have no frequency dependence. By dividing the measured power spectrum of echoes from RBCs in the lumen by that of echoes from a posterior wall of the vein in the dorsum manus, the attenuation property of the propagating medium and the frequency responses of transmitting and receiving transducers are removed from the former spectrum. RBC aggregation was assessed by the diameter of a scatterer, which was estimated by minimizing the square difference between the measured normalized power spectrum and the theoretical power spectrum. In this study, spherical scatterers with diameters of 5, 11, 15, and 30 µm were measured in basic experiments. The estimated scatterer diameters were close to the actual diameters. Furthermore, the transient change of the scatterer diameters were measured in an in vivo experiment with respect to a 24-year-old healthy male during the avascularization using a cuff. The estimated diameters (12-22 µm) of RBCs during avascularization were larger than the diameters (4-8 µm) at rest and after recirculation. These results show the possibility of the use of the proposed method for noninvasive assessment of RBC aggregation.

  1. Global collapse and J integral analysis for inner-diameter defected curved plates in tension

    International Nuclear Information System (INIS)

    Hertelé, Stijn; Verstraete, Matthias; Denys, Rudi; De Waele, Wim

    2013-01-01

    Reference stress equations are widely used to predict both the limit load and the J integral response of defected structures. Their validity is key to performing a safe assessment of structural integrity (plastic collapse and fracture). An analytical reference stress equation based upon global collapse has recently been developed for curved plates with a part-through defect located at the inner diameter surface. This equation predicts decreasing reference stress values as plate curvature increases. To qualify the predictions, the authors have performed a series of finite element analyses covering a wide range of possible geometries. This paper compares the numerically obtained limit loads and J integral responses with the analytical predictions of the reference stress equation. The finite element results generally confirm the decrease of reference stress with increasing plate curvature. Highly pronounced differences may occur between flat plates and slightly curved plates. Overall, the analytically predicted decrease in reference stress is overestimated for small defects but is representative for larger defects. -- Highlights: • A reference stress equation for inner-diameter defected curved plates in tension was developed earlier. • The equation predicts a lower reference stress as plate curvature increases. • The analytical predictions are validated through finite element analysis. • Collapse and J integral are insensitive to curvature for small defects. • For large defects, the analytically predicted trend is confirmed

  2. A large-diameter hollow-shaft cryogenic motor based on a superconducting magnetic bearing for millimeter-wave polarimetry.

    Science.gov (United States)

    Johnson, B R; Columbro, F; Araujo, D; Limon, M; Smiley, B; Jones, G; Reichborn-Kjennerud, B; Miller, A; Gupta, S

    2017-10-01

    In this paper, we present the design and measured performance of a novel cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a HWP is rapidly rotated in front of a polarization analyzer or polarization-sensitive detector. This polarimetry technique is commonly used in cosmic microwave background polarization studies. The SMB we use is composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor because the HWP is ultimately installed in the rotor. The motor presented here has a 100 mm diameter rotor aperture. However, the design can be scaled up to rotor aperture diameters of approximately 500 mm. Our motor system is composed of four primary subsystems: (i) the rotor assembly, which includes the NdFeB ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an incremental encoder, and (iv) the drive electronics. While the YBCO is cooling through its superconducting transition, the rotor is held above the stator by a novel hold and release mechanism. The encoder subsystem consists of a custom-built encoder disk read out by two fiber optic readout sensors. For the demonstration described in this paper, we ran the motor at 50 K and tested rotation frequencies up to approximately 10 Hz. The feedback system was able to stabilize the rotation speed to approximately 0.4%, and the measured rotor orientation angle uncertainty is less than 0.15°. Lower temperature operation will require additional development activities, which we will discuss.

  3. A large-diameter hollow-shaft cryogenic motor based on a superconducting magnetic bearing for millimeter-wave polarimetry

    Science.gov (United States)

    Johnson, B. R.; Columbro, F.; Araujo, D.; Limon, M.; Smiley, B.; Jones, G.; Reichborn-Kjennerud, B.; Miller, A.; Gupta, S.

    2017-10-01

    In this paper, we present the design and measured performance of a novel cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a HWP is rapidly rotated in front of a polarization analyzer or polarization-sensitive detector. This polarimetry technique is commonly used in cosmic microwave background polarization studies. The SMB we use is composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor because the HWP is ultimately installed in the rotor. The motor presented here has a 100 mm diameter rotor aperture. However, the design can be scaled up to rotor aperture diameters of approximately 500 mm. Our motor system is composed of four primary subsystems: (i) the rotor assembly, which includes the NdFeB ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an incremental encoder, and (iv) the drive electronics. While the YBCO is cooling through its superconducting transition, the rotor is held above the stator by a novel hold and release mechanism. The encoder subsystem consists of a custom-built encoder disk read out by two fiber optic readout sensors. For the demonstration described in this paper, we ran the motor at 50 K and tested rotation frequencies up to approximately 10 Hz. The feedback system was able to stabilize the rotation speed to approximately 0.4%, and the measured rotor orientation angle uncertainty is less than 0.15°. Lower temperature operation will require additional development activities, which we will discuss.

  4. Ultrasonographic fetometry formulas of inner chorionic cavity diameter and biparietal diameter for medium-sized dogs can be used in giant breeds.

    Science.gov (United States)

    Socha, Piotr; Janowski, Tomasz; Bancerz-Kisiel, Agata

    2015-09-15

    The aim of this study was to evaluate the suitability of the ultrasonographic fetometry method, involving inner chorionic cavity diameter (ICC) and biparietal diameter (BP) measurements, to predict the parturition date in giant breed dogs. Overall, 30 ICC and 24 BP measurements were taken on 24 giant breed bitches. The measured values were substituted into Luvoni and Grioni (2000) formulas for medium-sized bitches because formulas with ICC and BP to dogs with a body mass greater than 40 kg have not been defined. The accuracy of the parturition date predictions proved the method to be highly useful in the observed group of dogs. Prediction accuracy in the giants ranged between 54.16% (± 1 day, using BP) and 90% (± 2 days, using ICC), depending on the parameter measured and precision levels used. Numerically, the results obtained using ICC were better; however, no statistically significant differences between ICC and BP accuracy were found when comparing the effectiveness of the parturition date predictions. Regression lines based on the own fetometric measurements were highly convergent with the lines defined by Luvoni and Grioni (2000) formulas for medium-sized bitches. This outcome suggests a similar gestational development of fetuses in giant dogs and the possible use of Luvoni and Grioni (2000) formulas for medium-sized dogs with breeds weighing greater than 40 kg. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Influence of the implant-abutment connection design and diameter on the screw joint stability

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung

    2014-01-01

    PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398

  6. Influence of the implant-abutment connection design and diameter on the screw joint stability.

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo

    2014-04-01

    This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

  7. Stability of high β large aspect ratio tokamaks

    International Nuclear Information System (INIS)

    Cowley, S.C.

    1991-10-01

    High β(β much-gt ε/q 2 ) large aspect ratio (ε much-gt 1) tokamak equilibria are shown to be always stable to ideal M.H.D. modes that are localized about a flux surface. Both the ballooning and interchange modes are shown to be stable. This work uses the analytic high β large aspect ratio tokamak equilibria developed by Cowley et.al., which are valid for arbitrary pressure and safety factor profiles. The stability results make no assumption about these profiles or the shape of the boundary. 14 refs., 4 figs

  8. Development of large-volume, high-resolution tracking detectors based on capillaries filled with liquid scintillator

    International Nuclear Information System (INIS)

    Buontempo, S.; Fabre, J.P.; Frenkel, A.; Gregoire, G.; Hoepfner, K.; Konijn, J.; Kozarenko, E.; Kreslo, I.; Kushnirenko, A.; Martellotti, G.; Michel, L.; Mondardini, M.R.; Penso, G.; Siegmund, W.P.; Strack, R.; Tyukov, V.; Vasilchenko, V.; Vilain, P.; Wilquet, G.; Winter, K.; Wong, H.; Zymin, K.

    1995-01-01

    Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving this by using glass capillaries filled with organic liquid scintillator is being investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180x2x2 cm 3 has been assembled from capillaries with 20 μm diameter pores. The readout scheme currently in operation allows the reading of similar 5x10 5 channels using a single chain of image intensifiers having a resolution of σ similar 20 μm. Following the development of new liquid scintillators and purification methods an attenuation length of similar 3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end. (orig.)

  9. Study of ebullition inside a rectangular inclinable channel, of large hydraulic diameter

    International Nuclear Information System (INIS)

    Nehme, H.

    1997-01-01

    This work is performed in the framework of the investigation of-Severe Accidents of Water Cooled Nuclear Power Plants (PWR). A concept of molten core recovery is based on a retention in the lower head of the reactor vessel or in core-catchers which are externally cooled by water, Critical heat flux must be avoided in this external natural convection two-phase flow. The SULTAN experiment has been launched in order to investigate two-phase flow characteristics at experiment is described. Tests are performed under forced convection conditions for extended analytical investigation of the flow characteristics. They are mainly aimed to measure pressure drops, onset of critical heat flux (CHF), temperature and void fraction profiles in the flow. These results are describe and analyzed in a second part. The flow reveals to be very different from the classical flow in narrow channels. The difference is mainly due to 2-D effects and internal flow re-circulations. The limit of validity of 1-D analytical description of the flow is tested. This approach is improved by the proposal of a new correlation for the prediction of net vapor generation point and for the calculation of the mean density along the subcooled part of the flow. New CHF correlations are proposed. CHF is shown to be the same order of magnitude as these measured on the ULPU facility in UCSB and at the MIT. However 1-D approach has limitations at high qualities for large and inclined channels. A better description must be linked to the use of multi-dimensional numerical two-phase flow codes. (author)

  10. On the diameter of dot-critical graphs

    Directory of Open Access Journals (Sweden)

    Doost Ali Mojdeh

    2009-01-01

    Full Text Available A graph G is \\(k\\-dot-critical (totaly \\(k\\-dot-critical if \\(G\\ is dot-critical (totaly dot-critical and the domination number is \\(k\\. In the paper [T. Burtona, D. P. Sumner, Domination dot-critical graphs, Discrete Math, 306 (2006, 11-18] the following question is posed: What are the best bounds for the diameter of a \\(k\\-dot-critical graph and a totally \\(k\\-dot-critical graph \\(G\\ with no critical vertices for \\(k \\geq 4\\? We find the best bound for the diameter of a \\(k\\-dot-critical graph, where \\(k \\in\\{4,5,6\\}\\ and we give a family of \\(k\\-dot-critical graphs (with no critical vertices with sharp diameter \\(2k-3\\ for even \\(k \\geq 4\\.

  11. Database for Pressure Tube Diameter and Operation Data of Wolsong NPP

    International Nuclear Information System (INIS)

    Jung, Jong Yeob; Kim, W. Y.; Bae, J. H.; Park, J. H.

    2010-12-01

    Pressure tube of CANDU reactor which is a long cylindrical shape of its diameter about 10 cm and length of about 6m, can be expanded toward both radial and axial directions due to irradiation under the high pressure and temperature condition. As the irradiation period increases, the radial expansion due to creep of the pressure tube increases. The radial expansion of the pressure tube comes out the reduction of the coolability and it results in the power deration. The objectives of the current work is to establish the database for the measured diametral data of pressure tube and operational data from Wolsong NPP as a preliminary work of developing the prediction model for pressure tube diameter. In order to develop the database, measured data for total 86 channels were collected from Wolsong NPP 1, 2, 3 and 4 and analyzed. Based on the provided data, the operational conditions such as an axial temperature and a pressure of the channel and neutron fluxes were derived. All data were analysed to derive the correlation between the pressure tube diameter and the other operational parameters

  12. Ecology, environmental requirements and conservation of corticioid fungi occupying small diameter dead wood

    OpenAIRE

    Juutilainen, Katja

    2016-01-01

    The increasing human impact upon the biosphere of earth is causing profound changes across all spatial scales. The ability to cope with human-induced disturbance varies among organisms; specialist species are more negatively affected than generalist species. Forests are among the most heavily affected ecosystems; especially the dead wood associated organisms are in peril. The earlier research has strongly focused on large diameter dead wood and associated species. The ...

  13. Organosilane oxidation by water catalysed by large gold nanoparticles in a membrane reactor

    NARCIS (Netherlands)

    Gitis, V.; Beerthuis, R.; Shiju, N.R.; Rothenberg, G.

    2014-01-01

    We show that gold nanoparticles catalyse the oxidation of organosilanes using water as oxidant at ambient conditions. Remarkably, monodispersions of small gold particles (3.5 nm diameter) and large ones (6-18 nm diameter) give equally good conversion rates. This is important because separating large

  14. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  15. Modelling of tomato stem diameter growth rate based on physiological responses

    International Nuclear Information System (INIS)

    Li, L.; Tan, J.; Lv, T.

    2017-01-01

    The stem diameter is an important parameter describing the growth of tomato plant during vegetative growth stage. A stem diameter growth model was developed to predict the response of plant growth under different conditions. By analyzing the diurnal variations of stem diameter in tomato (Solanum lycopersicum L.), it was found that the stem diameter measured at 3:00 am was the representative value as the daily basis of tomato stem diameter. Based on the responses of growth rate in stem diameter to light and temperature, a linear regression relationship was applied to establish the stem diameter growth rate prediction model for the vegetative growth stage in tomato and which was further validated by experiment. The root mean square error (RMSE) and relative error (RE) were used to test the correlation between measured and modeled stem diameter variations. Results showed that the model can be used in prediction for stem diameter growth rate at vegetative growth stage in tomato. (author)

  16. The role of facial canal diameter in the pathogenesis and grade of Bell's palsy: a study by high resolution computed tomography.

    Science.gov (United States)

    Celik, Onur; Eskiizmir, Gorkem; Pabuscu, Yuksel; Ulkumen, Burak; Toker, Gokce Tanyeri

    .67) and stylomastoid foramen (p=0.16). We did not find any relationship between the HB grade and the facial canal diameter at the level of labyrinthine segment (p=0.41), tympanic segment (p=0.12), mastoid segment (p=0.14), geniculate ganglion (p=0.13) and stylomastoid foramen (p=0.44), while we found significant relationship at the level of second genu (p=0.02). We found the diameter of labyrinthine segment of facial canal as an anatomic risk factor for Bell's palsy. We also found significant relationship between the HB grade and FC diameter at the level of second genu. Future studies (MRI-CT combined or 3D modeling) are needed to promote this possible relevance especially at second genu. Thus, in the future it may be possible to selectively decompress particular segments in high grade BP patients. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Calibration of the Diameter Distribution Derived from the Area-based Approach with Individual Tree-based Diameter Estimates Using the Airborne Laser Scanning

    Science.gov (United States)

    Xu, Q.; Hou, Z.; Maltamo, M.; Tokola, T.

    2015-12-01

    Diameter distributions of trees are important indicators of current forest stand structure and future dynamics. A new method was proposed in the study to combine the diameter distributions derived from the area-based approach (ABA) and the diameter distribution derived from the individual tree detection (ITD) in order to obtain more accurate forest stand attributes. Since dominant trees can be reliably detected and measured by the Lidar data via the ITD, the focus of the study is to retrieve the suppressed trees (trees that were missed by the ITD) from the ABA. Replacement and histogram matching were respectively employed at the plot level to retrieve the suppressed trees. Cut point was detected from the ITD-derived diameter distribution for each sample plot to distinguish dominant trees from the suppressed trees. The results showed that calibrated diameter distributions were more accurate in terms of error index and the entire growing stock estimates. Compared with the best performer between the ABA and the ITD, calibrated diameter distributions decreased the relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points respectively. Calibration improved the estimation of pulpwood fraction significantly, resulting in a negligible bias of the estimated entire growing stock.

  18. Influence of core diameter and length of polymer optical fiber on Brillouin scattering properties

    Science.gov (United States)

    Mizuno, Yosuke; Ishigure, Takaaki; Nakamura, Kentaro

    2012-02-01

    Brillouin scattering in perfluorinated graded-index polymer optical fibers (PFGI-POFs) is potentially useful in developing high-accuracy distributed temperature sensors with reduced strain sensitivity. In this study, we investigate, both experimentally and theoretically, the influence of the fiber core diameter and length on the Brillouin gain spectra (BGS) in PFGI-POFs. First, we show that smaller core diameter drastically enhances the Stokes power using PFGI-POFs with 62.5-μm and 120-μm core diameters, and discuss the Brillouin threshold power. Then, we demonstrate that the PFGI-POF length has little influence on the BGS when the length is longer than 50 m. We also predict that, at 1.55-μm wavelength, it is difficult to reduce the Brillouin threshold power of PFGI-POFs below that of long silica single-mode fibers even if their core diameter is sufficiently reduced to satisfy the single-mode condition. Finally, making use of the enhanced Stokes signal, we confirm the Brillouin linewidth narrowing effect.

  19. Study on flow-induced vibration of large-diameter pipings in a sodium-cooled fast reactor. Influence of elbow curvature on velocity fluctuation field

    International Nuclear Information System (INIS)

    Ono, Ayako; Kimura, Nobuyuki; Kamide, Hideki; Tobita, Akira

    2010-02-01

    The main cooling system of Japan Sodium-cooled Fast Reactor (JSFR) consists of two loops to reduce the plant construction cost. In the design of JSFR, sodium coolant velocity is beyond 9m/s in the primary hot leg pipe with large-diameter (1.3m). The maximum Reynolds number in the piping reaches 4.2x10 7 . The hot leg pipe having a 90 degree elbow with curvature ratio of r/D=1.0, so-called 'short elbow', which enables a compact reactor vessel. In sodium cooled fast reactors, the system pressure is so low that thickness of pipings in the cooling system is thinner than that in LWRs. Under such a system condition in the cooling system, the flow-induced vibration (FIV) is concerned at the short elbow. The evaluation of the structural integrity of pipings in JSFR should be conducted based on a mechanistic approach of FIV at the elbow. It is significant to obtain the knowledge of the fluctuation intensity and spectra of velocity and pressure fluctuations in order to grasp the mechanism of the FIV. In this study, water experiments were conducted. Two types of 1/8 scaled elbows with different curvature ratio, r/D=1.0, 1.5, were used to investigate the influence of curvature on velocity fluctuation at the elbow. The velocity fields in the elbows were measured using a high speed PIV method. Unsteady behavior of secondary flow at the elbow outlet and separation flow at the inner wall of elbow were observed in the two types of elbows. It was found that the growth of secondary flow correlated with the flow fluctuation near the inside wall of the elbow. (author)

  20. Pilot study: safety and effectiveness of simple ultrasound-guided high-intensity focused ultrasound ablating uterine leiomyoma with a diameter greater than 10 cm.

    Science.gov (United States)

    Hou, Ruijie; Wang, Liwei; Li, Shaoping; Rong, Fengmin; Wang, Yuanyuan; Qin, Xuena; Wang, Shijin

    2018-02-01

    The study aimed to prospectively investigate whether uterine leiomyoma greater than 10 cm in diameter could be treated with simple ultrasound-guided high-intensity focused ultrasound (USgHIFU) in one-time treatment. A total of 36 patients with 36 symptomatic uterine leiomyoma greater than 10 cm in diameter who underwent simple USgHIFU treatment alone were analysed. Enhanced MRI was performed before and after HIFU treatment, and all patients had follow-up for 6 months after treatment. Symptom severity scores, treatment time, treatment speed, ablation rate, energy effect ratio, uterine leiomyoma regression rate, adverse events, liver and kidney functions, coagulation function and routine blood count were included in the study endpoints. The mean diameter of uterine leiomyoma was 11.2 ± 1.3 cm (10.0-14.3 cm). The median treatment time and treatment speed were 104.0 min (90.0-140.0 min) and 118.8 cm 3  h -1  (86.2-247.1 cm 3  h -1 ), respectively. The ablation rate of uterine leiomyoma was 71.9 ± 20.4% (32.1-100.0%), and the regression rate of uterine leiomyoma was 40.8 ± 7.5% (25.6-59.9%) at 6 months after treatment. The mean symptom severity scores decreased by an average of approximately 8.6 ± 2.3 (5-14) points. There were no significant changes in haemogram and blood chemical indexes of patients, except for the transient elevation of aspartate aminotransferase, total bilirubin and white blood cells after treatment. No serious adverse reactions occurred. According to our preliminary results, simple USgHIFU is a safe and effective single-treatment method of treating uterine leiomyoma greater than 10 cm in diameter and is an almost innocuous alternative therapeutic strategy. Advances in knowledge: The conclusions indicate simple USgHIFU is safe and effective as one-time treatment of uterine leiomyoma greater than 10 cm in diameter, it could be a promising therapeutic strategy.

  1. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  2. Application of round grating angle measurement composite error amendment in the online measurement accuracy improvement of large diameter

    Science.gov (United States)

    Wang, Biao; Yu, Xiaofen; Li, Qinzhao; Zheng, Yu

    2008-10-01

    The paper aiming at the influence factor of round grating dividing error, rolling-wheel produce eccentricity and surface shape errors provides an amendment method based on rolling-wheel to get the composite error model which includes all influence factors above, and then corrects the non-circle measurement angle error of the rolling-wheel. We make soft simulation verification and have experiment; the result indicates that the composite error amendment method can improve the diameter measurement accuracy with rolling-wheel theory. It has wide application prospect for the measurement accuracy higher than 5 μm/m.

  3. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  4. Influence of the pipe diameter on the structure of the gas-liquid interface in a vertical two-phase pipe flow

    International Nuclear Information System (INIS)

    Prasser, H. M.; Beyer, M.; Boettger, A.; Carl, H.; Lucas, D.; Schaffrath, A.; Schutz, P.; Weiss, F. P.; Zschau, J.

    2003-01-01

    Two-phase flow tests in a 194.1 mm diameter vertical pipe (DN200) with an air-water mixture are reported. Close to the upper end of a 9 m tall test section a wire-mesh sensor is installed that delivers instantaneous void fraction distributions over the entire cross section with time resolution of 2500 frames per second. The sensor disposes of 64 x 64 measuring points, which corresponds to a spatial resolution of 3 mm. Beside an fast flow visualisations, void-fraction profiles and bubble size distributions were obtained. Earlier, similar experiments were carried out in a pipe of 51.2 mm inner diameter (DN50). A comparison of the data from the two different facilities allows to study the scaling effects on void fraction profiles, bubbles size distributions and the flow patterns. In the small pipe, the increase of the air flow rate leads to a transition from bubbly via slug to churn turbulent flow. The transition to slug flow is accompanied by the appearance of a second peak in the bubble size distribution that corresponds to the class of large Taylor bubbles. A similar qualitative behaviour was found in the large pipe, though the large bubble fraction has a significantly bigger mean diameter at identical superficial velocities, the peak is less tall but wider. Bubbles move more freely than in the small pipe, since the confining action of the pipe walls to the flow is less pronounced, while the large Taylor bubbles occupy almost the entire cross section in case of the small pipe. Furthermore, the bubbles show much more deformations in the large pipe. Shapes of such large bubbles were characterised in three dimensions for the first time. They can rather be complicated and far from the shape of ideal Taylor bubbles. Also the small bubble fraction tends to bigger sizes in the large pipe

  5. A High-Emissivity Blackbody with Large Aperture for Radiometric Calibration at Low-Temperature

    Science.gov (United States)

    Ko, Hsin-Yi; Wen, Bor-Jiunn; Tsa, Shu-Fei; Li, Guo-Wei

    2009-02-01

    A newly designed high-emissivity cylindrical blackbody source with a large diameter aperture (54 mm), an internal triangular-grooved surface, and concentric grooves on the bottom surface was immersed in a temperature-controlled, stirred-liquid bath. The stirred-liquid bath can be stabilized to better than 0.05°C at temperatures between 30 °C and 70 °C, with traceability to the ITS-90 through a platinum resistance thermometer (PRT) calibrated at the fixed points of indium, gallium, and the water triple point. The temperature uniformity of the blackbody from the bottom to the front of the cavity is better than 0.05 % of the operating temperature (in °C). The heat loss of the cavity is less than 0.03 % of the operating temperature as determined with a radiation thermometer by removing an insulating lid without the gas purge operating. Optical ray tracing with a Monte Carlo method (STEEP 3) indicated that the effective emissivity of this blackbody cavity is very close to unity. The size-of-source effect (SSE) of the radiation thermometer and the effective emissivity of the blackbody were considered in evaluating the uncertainty of the blackbody. The blackbody uncertainty budget and performance are described in this paper.

  6. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    Background: Normal values of lumbar vertebral canal diameters are useful in facilitating diagnosis of lumbar vertebral canal stenosis. Various studies have established variation on values between different populations, gender, age, and ethnic groups. Objectives: To determine the lumbar vertebral canal diameters in adult ...

  7. Diameter dependent failure current density of gold nanowires

    International Nuclear Information System (INIS)

    Karim, S; Maaz, K; Ali, G; Ensinger, W

    2009-01-01

    Failure current density of single gold nanowires is investigated in this paper. Single wires with diameters ranging from 80 to 720 nm and length 30 μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density was investigated while keeping the wires embedded in the polymer matrix and ramping up the current until failure occurred. The current density is found to increase with diminishing diameter and the wires with a diameter of 80 nm withstand 1.2 x 10 12 A m -2 before undergoing failure. Possible reasons for these results are discussed in this paper.

  8. Effective diameters and corresponding states of fluids

    Science.gov (United States)

    Del Río, Fernando

    Effective hard-sphere diameters of fluids with purely repulsive interactions are derived from a generalized corresponding-states principle of Leland, Rowlinson and coworkers. Various alternative definitions are discussed and related. Virial expansions of the effective diameters and their corresponding volumes are obtained and compared with results of perturbation theory. Applications are made to inverse-power potentials, the repulsive part of the Lennard-Jones potential and hard spherocylinders and dumbells.

  9. Large, Tunable Magnetoresistance in Nonmagnetic III-V Nanowires.

    Science.gov (United States)

    Li, Sichao; Luo, Wei; Gu, Jiangjiang; Cheng, Xiang; Ye, Peide D; Wu, Yanqing

    2015-12-09

    Magnetoresistance, the modulation of resistance by magnetic fields, has been adopted and continues to evolve in many device applications including hard-disk, memory, and sensors. Magnetoresistance in nonmagnetic semiconductors has recently raised much attention and shows great potential due to its large magnitude that is comparable or even larger than magnetic materials. However, most of the previous work focus on two terminal devices with large dimensions, typically of micrometer scales, which severely limit their performance potential and more importantly, scalability in commercial applications. Here, we investigate magnetoresistance in the impact ionization region in InGaAs nanowires with 20 nm diameter and 40 nm gate length. The deeply scaled dimensions of these nanowires enable high sensibility with less power consumption. Moreover, in these three terminal devices, the magnitude of magnetoresistance can be tuned by the transverse electric field controlled by gate voltage. Large magnetoresistance between 100% at room temperature and 2000% at 4.3 K can be achieved at 2.5 T. These nanoscale devices with large magnetoresistance offer excellent opportunity for future high-density large-scale magneto-electric devices using top-down fabrication approaches, which are compatible with commercial silicon platform.

  10. Large vessel imaging using cosmic-ray muons

    International Nuclear Information System (INIS)

    Jenneson, P.M.

    2004-01-01

    Cosmic-ray muons are assessed for their practical use in the tomographic imaging of the internal composition of large vessels over 2 m in diameter. The technique is based on the attenuation and scattering of cosmic-ray muons passing through a vessel and has advantages over photon-based methods of tomography that it is extendable to object containing high-density materials over many tens of metres. The main disadvantage is the length of time required to produce images of sufficient resolution and hence cosmic ray muon tomography will be most suited to the imaging of large structures whose internal composition is effectively static for the duration of the imaging period. Simulation and theoretical results are presented here which demonstrate the feasibility of cosmic ray muon tomography

  11. Design of small diameter HT/HP sour service reeled rigid pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Daniel; Gouveia, Joao; Tardelli, Luciano [Tecnitas, Rio de Janeiro, RJ (Brazil)], e-mail: daniel.carneiro@br.bureauveritas.com; Parrilha, Rafael [Bureau Veritas Group, London (United Kingdom); Oazen, Eduardo; Cardoso, Carlos [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The paper presents an overview of the challenges overcome in the engineering design of two 219 mm diameter, 6 km length oil production pipelines, to be installed by reeling at Espirito Santo Basin, offshore Brazilian coast in 1500 m water depth. The high temperature and high pressure (HT/HP) operating conditions and sour content associated with the small diameter required to single well oil production would usually lead to flexible flow line solution in Brazilian fields. The decision of employing small diameter thick-walled rigid C-Mn steel pipelines with thick thermal insulation made necessary extensive engineering work to achieve a safe and robust thermal expansion control arrangement, including the design of walking mitigation and buckle initiation apparatus; a feasible weld acceptance criterion covering both high cycle fatigue due to pipe lay and vortex induced vibration (VIV) at free spans, and high strain low cycle fatigue and fracture growth induced by reeling installation and in-service lateral buckling. Several studies were performed using highly non-linear three-dimensional finite element models considering: pipe-soil interaction with full 3D seabed bathymetry; load history maintained from pipe lay to operational cycles, including temperature transient effects; high plastic strains (including steel properties de-rating due to high temperature) and section ovalization; mechanical contact between pipe and appurtenances during both installation and operational phases. Pipe-soil interaction comprised embedment considering dynamic effects of pipe lay and full non-linear lateral and axial response curves including break-out and residual resistance. Strain concentration factors due to field joints were evaluated using detailed solid models considering non-linear response of both steel and insulation materials. Susceptibility to VIV at free spans was assessed considering post loaded deformed span natural frequencies, including multi-span interaction effects and

  12. Comparison between transcerebellar diameter with biparietal diameter of ultrasound for gestational age measurement in third trimester of pregnancy

    International Nuclear Information System (INIS)

    Naseem, F.; Fatima, N.; Yasmeen, S.; Saleem, S.

    2013-01-01

    To determine the frequency of correct assessment by transcerebeller diameter (TCD) versus biparietal diameter (BPD) for gestational age measurement at 36 weeks of pregnancy using first day of last menstrual period (LMP) for actual period of gestation. Study Design: Quasi experimental. Place and Duration of Study: Department of Obstetrics and Gynaecology, Bahawal Victoria Hospital, Bahawalpur from May to November 2010. Methodology: This study was performed on 228 patients at 36 weeks of pregnancy fulfilling the inclusion criteria. Ultrasound measurements of TCD and BPD was made and compared with LMP. Collected data was analyzed by SPSS version 10. Proportoin of correct diagnosis by each measurement was determined and compared using chi-square test with significance at p < 0.05. Results: Out of 228 patients, TCD was found to give correct assessment in 209 patients (91.7%; p = 0.001) corresponding to the gestational age by LMP i.e 36 weeks. BPD was found to give correct assessment corresponding to the gestational age by LMP in 176 patients (77.2%). Conclusion: Although both BPD and TCD are accurate biometric parameters at 36 weeks of gestation, transcerebellar diameter is more reliable method of gestational age determination in third trimester of pregnancy than biparietal diameter. TCD can be used as a tool to assist in the assessment of gestational age in third trimester. (author)

  13. Quench protection and design of large high-current-density superconducting magnets

    International Nuclear Information System (INIS)

    Green, M.A.

    1981-03-01

    Although most large superconducting magnets have been designed using the concept of cryostability, there is increased need for large magnets which operate at current densities above the cryostable limit (greater than 10 8 Am -2 ). Large high current density superconducting magnets are chosen for the following reasons: reduced mass, reduced coil thickness or size, and reduced cost. The design of large high current density, adiabatically stable, superconducting magnets requires a very different set of design rules than either large cryostable superconducting magnets or small self-protected high current density magnets. The problems associated with large high current density superconducting magnets fall into three categories; (a) quench protection, (b) stress and training, and (c) cryogenic design. The three categories must be considered simultaneously. The paper discusses quench protection and its implication for magnets of large stored energies (this includes strings of smaller magnets). Training and its relationship to quench protection and magnetic strain are discussed. Examples of magnets, built at the Lawrence Berkeley Laboratory and elsewhere using the design guidelines given in this report, are presented

  14. High level of CA 125 due to large endometrioma.

    Science.gov (United States)

    Phupong, Vorapong; Chen, Orawan; Ultchaswadi, Pornthip

    2004-09-01

    CA 125 is a tumor-associated antigen. Its high levels are usually associated with ovarian malignancies, whereas smaller increases in the levels were associated with benign gynecologic conditions. The authors report a high level of CA 125 in a case of large ovarian endometrioma. A 45-year-old nulliparous Thai woman, presented with an increase of her abdominal girth for 7 months. Transabdominal ultrasonogram demonstrated a large ovarian cyst and multiple small leiomyoma uteri, and serum CA 125 level was 1,006 U/ml. The preoperative diagnosis was ovarian cancer with leiomyoma uteri. Exploratory laparotomy was performed. There were a large right ovarian endometrioma, small left ovarian endometrioma and multiple small leiomyoma. Total abdominal hysterectomy and bilateral salpingo-oophorectomy was performed and histopathology confirmed the diagnosis of endometrioma and leiomyoma. The serum CA 125 level declined to non-detectable at the 4th week. She was well at discharge and throughout her 4th week follow-up period Although a very high level of CA 125 is associated with a malignant process, it can also be found in benign conditions such as a large endometrioma. The case emphasizes the association of high levels of CA 125 with benign gynecologic conditions.

  15. In line inspection of multi-diameter and high-pressure pipelines in Brazil using combined technologies: magnetic flux leakage and ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Ginten, Markus; Brockhaus, Stephan; Bouaoua, Nourreddine; Klein, Stefan [ROSEN Technology and Research Center, Lingen (Germany); Bruening, Franz [ROSEN Brazil, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The simultaneous use of the magnetic flux leakage (MFL) method and the ultrasonic testing (UT) method on a single in line inspection (ILI) tool has been identified as a versatile and accurate solution for liquid pipelines. The combination of the two methods is complementary to the restrictions of each other. Also, the overall scope of the inspection is enlarged. General wall thinning and largely corroded areas are accurately and reliably scanned with the UT unit, while very detailed information about pitting corrosion is obtained from the MFL measurement. Blind spots of echo loss, as occasionally observed for the UT channels is compensated by the more robust measurement from the MFL sensors. Consequently, this technology has been the method of choice in an in line inspection project of an onshore long distance pipeline in Brazil, facing a variety of corrosion threats. The pipeline consists of several multi-diameter sections of 18/20 inches and 20/22 inches. Furthermore, the high gravity of product in combination with a height profile, an altitude of 1152 m MSL (Mean Sea Level) had to be crossed, leads to a maximum pressure of 220 bar. These boundary conditions had to be considered during the design of the ILI-tool. The paper discusses the experience made so far with the combined technology MFL and UT. The effective use of the inspection tool for the above mentioned pipeline as well as field results from a previous inspection are described. (author)

  16. Validity of using modified capillary column with larger diameter to study the Cs diffusion in local Taiwan laterite

    International Nuclear Information System (INIS)

    Tsing-Hai Wang; National Tsing Hua University, Hsinchu, Taiwan; Wen-Chun Yeh; Shih-Chin Tsai; Yi-Lin Jan; Shi-Ping Teng

    2008-01-01

    We have examined the working diameter of capillary columns with diameter of 5, 7, 10 and 20 mm. These modified capillary columns were carefully filled with local Taiwan laterite (LTL). The porosity and density of these packed columns was 0.51±0.02 g/g and 1.27±0.05 g/cm 3 , respectively. The diffusion experiments were then carried out in synthetic groundwater with Cs loading of 0.1mM at room temperature. Experimental results have shown that the diffusion profiles of modified capillary columns fit Fick's second law very well. This result revealed that the working diameter of a capillary column can be expanded to at least to 20 mm without affecting the validity of the derived diffusion coefficients. Among these columns, the ones with 5 mm diameter show the most consistent results of the derived K d , apparent and effective diffusion coefficients. Although the derived distribution and effective diffusion coefficients slightly decrease as the diameter of these columns increases due to the increase of the solid/liquid ratio. These values are still informative of the Cs diffusion in local Taiwan laterite. Moreover, our results clearly demonstrate the potential of using 'modified capillary method' to study the diffusion behaviors of concerned radionuclide because columns with large diameter enable the filling with more versatile geological substances. (author)

  17. Heritability of optic disc diameters: a twin study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Taarnhøj, Nina Charlotte; Mitchell, Paul

    2011-01-01

    , additive genetic factors (i.e. heritability) explained 77% (95% CI: 65-85%) of variation of vertical disc diameters, whereas estimated unshared environmental effect was 23% (95% CI: 15-35%). For vertical cup diameters, heritability accounted for 70% (95% CI: 55-80%) and environmental factors 30% (95% CI...

  18. Light-fuelled transport of large dendrimers and proteins.

    Science.gov (United States)

    Koskela, Jenni E; Liljeström, Ville; Lim, Jongdoo; Simanek, Eric E; Ras, Robin H A; Priimagi, Arri; Kostiainen, Mauri A

    2014-05-14

    This work presents a facile water-based supramolecular approach for light-induced surface patterning. The method is based upon azobenzene-functionalized high-molecular weight triazine dendrimers up to generation 9, demonstrating that even very large globular supramolecular complexes can be made to move in response to light. We also demonstrate light-fuelled macroscopic movements in native biomolecules, showing that complexes of apoferritin protein and azobenzene can effectively form light-induced surface patterns. Fundamentally, the results establish that thin films comprising both flexible and rigid globular particles of large diameter can be moved with light, whereas the presented material concepts offer new possibilities for the yet marginally explored biological applications of azobenzene surface patterning.

  19. Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing

    Directory of Open Access Journals (Sweden)

    Vicky Bouffard

    2011-01-01

    Full Text Available Objective. To compare center of mass (COM compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA and hip resurfacing (HR. Design. Observational study. Setting. Outpatient biomechanical laboratory. Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip prosthetic joint center (HPJC and the COM. The ratio (RHPJC-COM and the variability (CVHPJC-COM were compared between groups. Hip flexor, abductor, and adductor muscle strength was also correlated between groups while radiographic measurements were correlated with the outcome measures. Results. In the frontal plane, HR shows less variability than healthy controls at push-off and toe-off and RHPJC-COM is correlated with the muscle strength ratios (FRABD at heel contact, maximal weight acceptance, and mid stance. In the sagittal plane, LDH-THA has a higher RHPJC-COM than healthy controls at push-off, and CVHPJC-COM is significantly correlated with FRFLEX. Conclusions. One year after surgery, both groups of patients, LDH-THA and HR, demonstrate minor compensations at some specific instant of the gait cycle, in both frontal and sagittal planes. However, their locomotion pattern is similar to the healthy controls.

  20. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  1. High-resolution imaging of the large non-human primate brain using microPET: a feasibility study

    Science.gov (United States)

    Naidoo-Variawa, S.; Hey-Cunningham, A. J.; Lehnert, W.; Kench, P. L.; Kassiou, M.; Banati, R.; Meikle, S. R.

    2007-11-01

    The neuroanatomy and physiology of the baboon brain closely resembles that of the human brain and is well suited for evaluating promising new radioligands in non-human primates by PET and SPECT prior to their use in humans. These studies are commonly performed on clinical scanners with 5 mm spatial resolution at best, resulting in sub-optimal images for quantitative analysis. This study assessed the feasibility of using a microPET animal scanner to image the brains of large non-human primates, i.e. papio hamadryas (baboon) at high resolution. Factors affecting image accuracy, including scatter, attenuation and spatial resolution, were measured under conditions approximating a baboon brain and using different reconstruction strategies. Scatter fraction measured 32% at the centre of a 10 cm diameter phantom. Scatter correction increased image contrast by up to 21% but reduced the signal-to-noise ratio. Volume resolution was superior and more uniform using maximum a posteriori (MAP) reconstructed images (3.2-3.6 mm3 FWHM from centre to 4 cm offset) compared to both 3D ordered subsets expectation maximization (OSEM) (5.6-8.3 mm3) and 3D reprojection (3DRP) (5.9-9.1 mm3). A pilot 18F-2-fluoro-2-deoxy-d-glucose ([18F]FDG) scan was performed on a healthy female adult baboon. The pilot study demonstrated the ability to adequately resolve cortical and sub-cortical grey matter structures in the baboon brain and improved contrast when images were corrected for attenuation and scatter and reconstructed by MAP. We conclude that high resolution imaging of the baboon brain with microPET is feasible with appropriate choices of reconstruction strategy and corrections for degrading physical effects. Further work to develop suitable correction algorithms for high-resolution large primate imaging is warranted.

  2. High-resolution imaging of the large non-human primate brain using microPET: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Naidoo-Variawa, S [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Hey-Cunningham, A J [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Lehnert, W [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Kench, P L [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Kassiou, M [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Banati, R [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia); Meikle, S R [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825, Sydney (Australia)

    2007-11-21

    The neuroanatomy and physiology of the baboon brain closely resembles that of the human brain and is well suited for evaluating promising new radioligands in non-human primates by PET and SPECT prior to their use in humans. These studies are commonly performed on clinical scanners with 5 mm spatial resolution at best, resulting in sub-optimal images for quantitative analysis. This study assessed the feasibility of using a microPET animal scanner to image the brains of large non-human primates, i.e. papio hamadryas (baboon) at high resolution. Factors affecting image accuracy, including scatter, attenuation and spatial resolution, were measured under conditions approximating a baboon brain and using different reconstruction strategies. Scatter fraction measured 32% at the centre of a 10 cm diameter phantom. Scatter correction increased image contrast by up to 21% but reduced the signal-to-noise ratio. Volume resolution was superior and more uniform using maximum a posteriori (MAP) reconstructed images (3.2-3.6 mm{sup 3} FWHM from centre to 4 cm offset) compared to both 3D ordered subsets expectation maximization (OSEM) (5.6-8.3 mm{sup 3}) and 3D reprojection (3DRP) (5.9-9.1 mm{sup 3}). A pilot {sup 18}F-2-fluoro-2-deoxy-d-glucose ([{sup 18}F]FDG) scan was performed on a healthy female adult baboon. The pilot study demonstrated the ability to adequately resolve cortical and sub-cortical grey matter structures in the baboon brain and improved contrast when images were corrected for attenuation and scatter and reconstructed by MAP. We conclude that high resolution imaging of the baboon brain with microPET is feasible with appropriate choices of reconstruction strategy and corrections for degrading physical effects. Further work to develop suitable correction algorithms for high-resolution large primate imaging is warranted.

  3. Brain Arterial Diameters as a Risk Factor for Vascular Events.

    Science.gov (United States)

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-08-06

    Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score -2 and 2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  4. Diameter of titanium nanotubes influences anti-bacterial efficacy

    International Nuclear Information System (INIS)

    Ercan, Batur; Taylor, Erik; Webster, Thomas J; Alpaslan, Ece

    2011-01-01

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  5. Diameter of titanium nanotubes influences anti-bacterial efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Ercan, Batur; Taylor, Erik; Webster, Thomas J [School of Engineering, Brown University, Providence, RI 02917 (United States); Alpaslan, Ece, E-mail: thomas_webster@brown.edu [Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul (Turkey)

    2011-07-22

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  6. Diameter of titanium nanotubes influences anti-bacterial efficacy

    Science.gov (United States)

    Ercan, Batur; Taylor, Erik; Alpaslan, Ece; Webster, Thomas J.

    2011-07-01

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  7. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  8. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  9. Phospholipid electrospun nanofibers: effect of solvents and co-axial processing on morphology and fiber diameter

    DEFF Research Database (Denmark)

    Jørgensen, Lars; Qvortrup, Klaus; Chronakis, Ioannis S.

    2015-01-01

    Asolectin phospholipid nano-microfibers were prepared using electrospinning processing. The asolectin fibers were studied by scanning electron microscopy, and the fiber morphology was found to be strongly dependent on the phospholipid concentration and the solvents used. The solvents studied were...... chloroform : dimethylformamide (CHCl3 : DMF, 3 : 2 v/v), isooctane, cyclohexane and limonene, producing phospholipid fibers with average diameters in the range of 2.57 +/- 0.59 mu m, similar to 3-8 mu m, similar to 4-5 mu m and 14.3 +/- 2.7 mu m, respectively. The diameter of asolectin electrospun fibers...... solvent and the inner needle contains the asolectin solution in CHCl3: DMF, a substantial reduction in the average fiber diameter was observed. In particular, the average diameter of the fibers when DMF (a solvent with a high dielectric constant) was used as a sheath solvent was reduced by a factor...

  10. Diameter measurements of polystyrene particles with atomic force microscopy

    International Nuclear Information System (INIS)

    Garnaes, J

    2011-01-01

    The size of (nano) particles is a key parameter used in controlling their function. The particle size is also important in order to understand their physical and chemical properties and regulate their number in health and safety issues. In this work, the geometric diameters of polystyrene spheres of nominal diameter 100 nm are measured using atomic force microscopy. The measurements are based on the apex height and on the average distance between neighbouring spheres when they form a close-packed monolayer on a flat mica substrate. The most important influence parameters for the determination of the geometric diameter are the lateral air gaps and deformation of the spheres. The lateral air gaps are caused by significant size variations of the individual spheres, and a correction is calculated based on the simulation of packing of spheres. The deformation of the spheres is caused mainly by capillary forces acting when they are in contact with each other or with the mica substrate. Based on calculated capillary forces and the literature values of the elastic properties of the polystyrene and mica, the deformation is estimated to be 2 nm with a standard uncertainty of 2 nm. The geometric diameter of the polystyrene spheres was measured with a combined standard uncertainty of ≈3 nm. The measured vertical diameter of 92.3 nm and the certified mobility equivalent diameter measured by differential mobility analysis (DMA) are marginally consistent at a confidence level of 95%. However, the measured lateral geometric diameter was 98.9 nm and is in good agreement with DMA

  11. Morphometric analysis of the diameter and g-ratio of the myelinated nerve fibers of the human sciatic nerve during the aging process.

    Science.gov (United States)

    Ugrenović, Sladjana; Jovanović, Ivan; Vasović, Ljiljana; Kundalić, Braca; Čukuranović, Rade; Stefanović, Vladisav

    2016-06-01

    Myelinated nerve fibers suffer from different degrees of atrophy with age. The success of subsequent regeneration varies. The aim of this research was to analyze myelinated fibers of the human sciatic nerve during the aging process. Morphometric analysis was performed on 17 cases with an age range from 9 to 93 years. The outer and inner diameter of 100 randomly selected nerve fibers was measured in each of the cases evaluated, and the g-ratio (axonal diameter/outer diameter of the whole nerve fiber) of each was calculated. Scatter plots of the diameters and g-ratios of the analyzed fibers were then analyzed. Nerve fibers of each case were classified into three groups according to the g-ratio values: group I (g-ratio lower than 0.6), group II (g-ratio from 0.6 to 0.7) and group III (g-ratio higher than 0.7). Afterwards, nerve fibers of group II were further classified into small and large subgroups. The percentages of each group of nerve fibers were computed for each case and these values were used for correlational and bivariate linear regression analysis. The percentage of myelinated nerve fibers with large diameter and optimal g-ratio of the sciatic nerve declines significantly with age. This is accompanied by a simultaneous significant increase in the percentage of small myelinated fibers with g-ratio values close to 1 that occupy the upper left quadrant of the scatter plot. It can be concluded that aging of the sciatic nerve is associated with significant atrophy of large myelinated fibers. Additionally, a significant increase in regenerated nerve fibers with thinner myelin sheath is observed with age, which, together with the large myelinated fiber atrophy, might be the cause of the age-related decline in conduction velocity. A better understanding of the changes in aging peripheral nerves might improve interpretation of their pathological changes, as well as comprehension of their regeneration in individuals of different age.

  12. Scoping calculations for design and analysis of large reactor vessels for liquid-metal fast breeder reactor (LMFBR) plants

    International Nuclear Information System (INIS)

    Fiala, C.; Kulak, R.F.; Ma, D.C.; Pan, Y.C.; Seidensticker, R.W.; Wang, C.Y.; Zeuch, W.R.

    1982-01-01

    Reactor vessels for commercial-sized LMFBR plants are quite large - ranging 40 to 70 ft in diameter and 50 to 70 ft in overall depth. These stainless steel vessels contain liquid sodium at relatively low pressures, but at high temperatures. The resulting thin-walled vessels present the structural designer and analyst with special problems, particularly in providing a balanced design to accommodate seismic loads, design basis accident loads, and thermal loadings. A comprehensive set of scoping calculations - though preliminary in detail and depth of design - provides substantial guidance to the vessel designer for subsequent design iterations. Emphasis is placed on the analysis of the large-diameter top closure of the vessel - the deck structure

  13. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  14. Scalable Algorithms for Large High-Resolution Terrain Data

    DEFF Research Database (Denmark)

    Mølhave, Thomas; Agarwal, Pankaj K.; Arge, Lars Allan

    2010-01-01

    In this paper we demonstrate that the technology required to perform typical GIS computations on very large high-resolution terrain models has matured enough to be ready for use by practitioners. We also demonstrate the impact that high-resolution data has on common problems. To our knowledge, so...

  15. Coupling of RF antennas to large volume helicon plasma

    Directory of Open Access Journals (Sweden)

    Lei Chang

    2018-04-01

    Full Text Available Large volume helicon plasma sources are of particular interest for large scale semiconductor processing, high power plasma propulsion and recently plasma-material interaction under fusion conditions. This work is devoted to studying the coupling of four typical RF antennas to helicon plasma with infinite length and diameter of 0.5 m, and exploring its frequency dependence in the range of 13.56-70 MHz for coupling optimization. It is found that loop antenna is more efficient than half helix, Boswell and Nagoya III antennas for power absorption; radially parabolic density profile overwhelms Gaussian density profile in terms of antenna coupling for low-density plasma, but the superiority reverses for high-density plasma. Increasing the driving frequency results in power absorption more near plasma edge, but the overall power absorption increases with frequency. Perpendicular stream plots of wave magnetic field, wave electric field and perturbed current are also presented. This work can serve as an important reference for the experimental design of large volume helicon plasma source with high RF power.

  16. Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energy

    International Nuclear Information System (INIS)

    Briels, T M P; Kos, J; Van Veldhuizen, E M; Ebert, U; Winands, G J J

    2008-01-01

    Positive and negative streamers are studied in ambient air at 1 bar; they emerge from a needle electrode placed 40 mm above a planar electrode. The amplitudes of the applied voltage pulses range from 5 to 96 kV; most pulses have rise times of 30 ns or shorter. Diameters, velocities and energies of the streamers are measured. Two regimes are identified; a low voltage regime where only positive streamers appear and a high voltage regime where both positive and negative streamers exist. Below 5 kV, no streamers emerge. In the range from 5 to 40 kV, positive streamers form, while the negative discharges only form a glowing cloud at the electrode tip, but no streamers. For 5-20 kV, diameters and velocities of the positive streamers have the minimal values of d = 0.2 mm and v ∼ 10 5 m s -1 . For 20-40 kV, their diameters increase by a factor of 6 while the voltage increases only by a factor of 2. Above the transition value of 40 kV, streamers of both polarities form; they strongly resemble each other, though the positive ones propagate further; their diameters continue to increase with applied voltage. For 96 kV, positive streamers attain diameters of 3 mm and velocities of 4 x 10 6 m s -1 ; negative streamers are about 20% slower and thinner. An empirical fit formula for the relation between velocity v and diameter d is v = 0.5d 2 mm -1 ns -1 for both polarities. Streamers of both polarities dissipate energies of the order of several millijoules per streamer while crossing the gap.

  17. Modelling diameter growth, mortality and recruitment of trees in ...

    African Journals Online (AJOL)

    Modelling diameter growth, mortality and recruitment of trees in miombo woodlands of Tanzania. ... Individual tree diameter growth and mortality models, and area-based recruitment models were developed. ... AJOL African Journals Online.

  18. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  19. Germination, seed diameter and pregerminative treatments in species with different purposes of use

    Directory of Open Access Journals (Sweden)

    Ricardo Vinicio Abril-Saltos

    2017-09-01

    Full Text Available The evaluation of vegetal species germination consents to know its characteristics and permits to understand the factors that influence this process. The aim of this research was to know the germination’s characteristics of some species, such as Eugenia stipitata McVaugh, Inga edulis Mart, Inga spectabilis (Vahl Wild, Piptocoma discolor (Kunth Pruski, Stachytarpheta cayennensis (Rich. Vahl, and Verbena officinalis L., and also their reaction to pregerminative treatments depending on the seed’s diameter. This study was carried out in Pastaza, Province of Pastaza, Ecuador, between February and June, 2014. Different diameters of seeds and pregerminative treatments were used in species, which did not present germination percentages higher than 40%. In the first practice I. edulis and I. spectabilis exceeded this value without treatment. Other species had lower values. Seeds were classified considering two diameters and two doses of gibberellin acid, this was applied to, and evaluated in the E. stipitata. In addition, scarification with sulfuric acid was done. After 45 days of its application, 100 ppm of gibberellic acid with larger seed diameter reported higher percentages of germination in S. cayenennsis, and in E. stipitata, which also interacted with the scarification. V. officinalis and P. discolor, did not present any response to the applications made. I. edulis and I. spectabilis presented high germination percentages without pregerminative treatments, E. stipitata and S. cayenennsis showed response to seed diameter and the applied treatments, while P discolor and V. officinalis did not show any response.

  20. Antimicrobial susceptibility and distribution of inhibition zone diameters of bovine mastitis pathogens in Flanders, Belgium.

    Science.gov (United States)

    Supré, K; Lommelen, K; De Meulemeester, L

    2014-07-16

    In dairy farms, antimicrobial drugs are frequently used for treatment of (sub)clinical mastitis. Determining the antimicrobial susceptibility of mastitis pathogens is needed to come to a correct use of antimicrobials. Strains of Staphylococcus aureus (n=768), Streptococcus uberis (n=939), Streptococcus dysgalactiae (n=444), Escherichia coli (n=563), and Klebsiella species (n=59) originating from routine milk samples from (sub)clinical mastitis were subjected to the disk diffusion method. Disks contained representatives of frequently used antibiotics in dairy. A limited number of clinical breakpoints were available through CLSI, and showed that susceptibility of Staph. aureus, E. coli, and Klebsiella was moderate to high. For streptococcal species however, a large variation between the tested species and the different antimicrobials was observed. In a next step, wild type populations were described based on epidemiological cut off values (EUCAST). Because of the limited number of official cut off values, the data were observed as a mastitis subpopulation and self-generated cut off values were created and a putative wild type population was suggested. The need for accurate clinical breakpoints for veterinary pathogens is high. Despite the lack of these breakpoints, however, a population study can be performed based on the distribution of inhibition zone diameters on the condition that a large number of strains is tested. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Development of a 5.5 m diameter vertical axis wind turbine, phase 3

    Science.gov (United States)

    Dekitsch, A.; Etzler, C. C.; Fritzsche, A.; Lorch, G.; Mueller, W.; Rogalla, K.; Schmelzle, J.; Schuhwerk, W.; Vollan, A.; Welte, D.

    1982-06-01

    In continuation of development of a 5.5 m diameter vertical axis windmill that consists in conception, building, and wind tunnel testing, a Darrieus rotor windpowered generator feeding an isolated network under different wind velocity conditions and with optimal energy conversion efficiency was designed built, and field tested. The three-bladed Darrieus rotor tested in the wind tunnel was equiped with two variable pitch Savonius rotors 2 m in diameter. By means of separate measures of the aerodynamic factors and the energy consumption, effect of revisions and optimizations on different elements was assessed. Pitch adjustement of the Savonius blades, lubrication of speed reducer, rotor speed at cut-in of generator field excitation, time constant of field excitation, stability conditions, switch points of ohmic resistors which combined with a small electric battery simulated a larger isolated network connected with a large storage battery, were investigated. Fundamentals for the economic series production of windpowered generators with Darrieus rotors for the control and the electric conversion system are presented.

  2. Novel Computerized Method for Measurement of Retinal Vessel Diameters

    Directory of Open Access Journals (Sweden)

    Hichem Guedri

    2017-03-01

    Full Text Available Several clinical studies reveal the relationship between alterations in the topologies of the human retinal blood vessel, the outcrop and the disease evolution, such as diabetic retinopathy, hypertensive retinopathy, and macular degeneration. Indeed, the detection of these vascular changes always has gaps. In addition, the manual steps are slow, which may be subjected to a bias of the perceiver. However, we can overcome these troubles using computer algorithms that are quicker and more accurate. This paper presents and investigates a novel method for measuring the blood vessel diameter in the retinal image. The proposed method is based on a thresholding segmentation and thinning step, followed by the characteristic point determination step by the Douglas-Peucker algorithm. Thereafter, it uses the active contours to detect vessel contour. Finally, Heron’s Formula is applied to assure the calculation of vessel diameter. The obtained results for six sample images showed that the proposed method generated less errors compared to other techniques, which confirms the high performance of the proposed method.

  3. Large fully retractable telescope enclosures still closable in strong wind

    Science.gov (United States)

    Bettonvil, Felix C. M.; Hammerschlag, Robert H.; Jägers, Aswin P. L.; Sliepen, Guus

    2008-07-01

    Two prototypes of fully retractable enclosures with diameters of 7 and 9 m have been built for the high-resolution solar telescopes DOT (Dutch Open Telescope) and GREGOR, both located at the Canary Islands. These enclosures protect the instruments for bad weather and are fully open when the telescopes are in operation. The telescopes and enclosures also operate in hard wind. The prototypes are based on tensioned membrane between movable but stiff bows, which fold together to a ring when opened. The height of the ring is small. The prototypes already survived several storms, with often snow and ice, without any damage, including hurricane Delta with wind speeds up to 68 m/s. The enclosures can still be closed and opened with wind speeds of 20 m/s without any problems or restrictions. The DOT successfully demonstrated the open, wind-flushing concept for astronomical telescopes. It is now widely recognized that also large future telescopes benefit from wind-flushing and retractable enclosures. These telescopes require enclosures with diameters of 30 m until roughly 100 m, the largest sizes for the ELTs (Extreme Large Telescopes), which will be built in the near future. We discuss developments and required technology for the realization of these large sizes.

  4. Numerical Study of Piping Limits for Installation of Large Diameter Buckets in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C.L.

    2010-01-01

    The bucket foundations, often referred as ‘suction caissons’, are large cylindrical structures, typically made in steel. The bucket foundations have the potential to be the cost-effective option for offshore wind turbines, if suction assisted penetration is employed. Suction installation may cause...... gradients developing in response to applied suction and the results are presented as simple closed form solutions useful for evaluation of suction thresholds against piping. These close form solutions are compared with large scale model test, performed in a natural seabed at a test site in Frederikshavn...

  5. Open principle for large high-resolution solar telescopes

    NARCIS (Netherlands)

    Hammerschlag, R.H.; Bettonvil, F.C.M.; Jägers, A.P.L.; Sliepen, G.

    2009-01-01

    Vacuum solar telescopes solve the problem of image deterioration inside the telescope due to refractive index fluctuations of the air heated by the solar light. However, such telescopes have a practical diameter limit somewhat over 1 m. The Dutch Open Telescope (DOT) was the pioneering demonstrator

  6. Some design aspects of high-speed vertical-axis wind turbines

    National Research Council Canada - National Science Library

    Templin, R. J; South, P

    1977-01-01

    ... (rotor height to diameter ratio, solidity, number of blades, etc.) for high-speed vertical-axis wind turbines from kilowatt to megawatt sizes and shows that very large turbines are theoretically feasible...

  7. Highly Flexible and High-Performance Complementary Inverters of Large-Area Transition Metal Dichalcogenide Monolayers

    KAUST Repository

    Pu, Jiang; Funahashi, Kazuma; Chen, Chang-Hsiao; Li, Ming-yang; Li, Lain-Jong; Takenobu, Taishi

    2016-01-01

    Complementary inverters constructed from large-area monolayers of WSe2 and MoS2 achieve excellent logic swings and yield an extremely high gain, large total noise margin, low power consumption, and good switching speed. Moreover, the WSe2

  8. Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI

    DEFF Research Database (Denmark)

    Dyrby, Tim B; Søgaard, Lise V; Hall, Matt G

    2013-01-01

    (max) ) on a scanner influence the sensitivity to a range of axon diameters. Multishell high-angular-diffusion-imaging (HARDI) protocols for G(max) of 60, 140, 200, and 300 mT/m were optimized for the pulsed-gradient-spin-echo (PGSE) sequence. Data were acquired on a fixed monkey brain and Monte-Carlo simulations......(max) for enhancing contrast between axon diameter distributions and are, therefore, relevant in general for microstructure imaging methods and highlight the need for increased G(max) on future commercial systems. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc....

  9. DEVELOPMENT OF A NINE INCH DIAMETER, MACH 5.5, MONORAIL, ROCKET SLED.

    Science.gov (United States)

    A nine inch diameter monorail rocket sled was designed, fabricated and tested at Holloman Air Force Base. The vehicle was designed to allow easy...replacement of appendages which were subject to severe aerodynamic heating and/or high wear rates. The monorail vehicle as described was shown to be

  10. A 1372-element Large Scale Hemispherical Ultrasound Phased Array Transducer for Noninvasive Transcranial Therapy

    International Nuclear Information System (INIS)

    Song, Junho; Hynynen, Kullervo

    2009-01-01

    Noninvasive transcranial therapy using high intensity focused ultrasound transducers has attracted high interest as a promising new modality for the treatments of brain related diseases. We describe the development of a 1372 element large scale hemispherical ultrasound phased array transducer operating at a resonant frequency of 306 kHz. The hemispherical array has a diameter of 31 cm and a 15.5 cm radius of curvature. It is constructed with piezoelectric (PZT-4) tube elements of a 10 mm in diameter, 6 mm in length and 1.4 mm wall thickness. Each element is quasi-air backed by attaching a cork-rubber membrane on the back of the element. The acoustic efficiency of the element is determined to be approximately 50%. The large number of the elements delivers high power ultrasound and offers better beam steering and focusing capability. Comparisons of sound pressure-squared field measurements with theoretical calculations in water show that the array provides good beam steering and tight focusing capability over an efficient volume of approximately 100x100x80 mm 3 with nominal focal spot size of approximately 2.3 mm in diameter at -6 dB. We also present its beam steering and focusing capability through an ex vivo human skull by measuring pressure-squared amplitude after phase corrections. These measurements show the same efficient volume range and focal spot sizes at -6 dB as the ones in water without the skull present. These results indicate that the array is sufficient for use in noninvasive transcranial ultrasound therapy.

  11. Diameter modulation of vertically aligned single-walled carbon nanotubes.

    Science.gov (United States)

    Xiang, Rong; Einarsson, Erik; Murakami, Yoichi; Shiomi, Junichiro; Chiashi, Shohei; Tang, Zikang; Maruyama, Shigeo

    2012-08-28

    We demonstrate wide-range diameter modulation of vertically aligned single-walled carbon nanotubes (SWNTs) using a wet chemistry prepared catalyst. In order to ensure compatibility to electronic applications, the current minimum mean diameter of 2 nm for vertically aligned SWNTs is challenged. The mean diameter is decreased to about 1.4 nm by reducing Co catalyst concentrations to 1/100 or by increasing Mo catalyst concentrations by five times. We also propose a novel spectral analysis method that allows one to distinguish absorbance contributions from the upper, middle, and lower parts of a nanotube array. We use this method to quantitatively characterize the slight diameter change observed along the array height. On the basis of further investigation of the array and catalyst particles, we conclude that catalyst aggregation-rather than Ostwald ripening-dominates the growth of metal particles.

  12. Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers

    Science.gov (United States)

    da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini

    2017-10-01

    The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.

  13. Deriving muscle fiber diameter from recorded single fiber potential.

    Science.gov (United States)

    Zalewska, Ewa

    2017-12-01

    The aim of the study was to estimate muscle fiber diameters through analysis of single muscle fiber potentials (SFPs) recorded in the frontalis muscle of a healthy subject. Our previously developed analytical and graphic method to derive fiber diameter from the analysis of the negative peak duration and the amplitude of SFP, was applied to a sample of ten SFPs recorded in vivo. Muscle fiber diameters derived from the simulation method for the sample of frontalis muscle SFPs are consistent with anatomical data for this muscle. The results confirm the utility of proposed simulation method. Outlying data could be considered as the result of a contribution of other fibers to the potential recorded using an SFEMG electrode. Our graphic tool provides a rapid estimation of muscle fiber diameter. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... model to enable axon diameter mapping in voxels with crossing fibers. We show in simulation that the technique can provide robust axon diameter estimates in a two-fiber crossing with the crossing angle as small as 45 degrees. Using ex vivo imaging data, we further demonstrate the feasibility...

  15. Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energy

    Energy Technology Data Exchange (ETDEWEB)

    Briels, T M P; Kos, J; Van Veldhuizen, E M; Ebert, U [Department of Applied Physics, Technische Universiteit Eindhoven, PO Box 513, 5600 MB Eindhoven (Netherlands); Winands, G J J [Department of Electrical Engineering, Technische Universiteit Eindhoven, PO Box 513, 5600 MB Eindhoven (Netherlands)], E-mail: e.m.v.veldhuizen@tue.nl, E-mail: ebert@cwi.nl

    2008-12-07

    Positive and negative streamers are studied in ambient air at 1 bar; they emerge from a needle electrode placed 40 mm above a planar electrode. The amplitudes of the applied voltage pulses range from 5 to 96 kV; most pulses have rise times of 30 ns or shorter. Diameters, velocities and energies of the streamers are measured. Two regimes are identified; a low voltage regime where only positive streamers appear and a high voltage regime where both positive and negative streamers exist. Below 5 kV, no streamers emerge. In the range from 5 to 40 kV, positive streamers form, while the negative discharges only form a glowing cloud at the electrode tip, but no streamers. For 5-20 kV, diameters and velocities of the positive streamers have the minimal values of d = 0.2 mm and v {approx} 10{sup 5} m s{sup -1}. For 20-40 kV, their diameters increase by a factor of 6 while the voltage increases only by a factor of 2. Above the transition value of 40 kV, streamers of both polarities form; they strongly resemble each other, though the positive ones propagate further; their diameters continue to increase with applied voltage. For 96 kV, positive streamers attain diameters of 3 mm and velocities of 4 x 10{sup 6} m s{sup -1}; negative streamers are about 20% slower and thinner. An empirical fit formula for the relation between velocity v and diameter d is v = 0.5d{sup 2} mm{sup -1} ns{sup -1} for both polarities. Streamers of both polarities dissipate energies of the order of several millijoules per streamer while crossing the gap.

  16. Uncovering the Forgotten Effect of Superior Cervical Ganglia on Pupil Diameter in Subarachnoid Hemorrhage: An Experimental Study.

    Science.gov (United States)

    Onen, Mehmet Resid; Yilmaz, Ilhan; Ramazanoglu, Leyla; Aydin, Mehmet Dumlu; Keles, Sadullah; Baykal, Orhan; Aydin, Nazan; Gundogdu, Cemal

    2018-01-01

    To investigate the relationship between neuron density of the superior cervical sympathetic ganglia and pupil diameter in subarachnoid hemorrhage. This study was conducted on 22 rabbits; 5 for the baseline control group, 5 for the SHAM group and 12 for the study group. Pupil diameters were measured via sunlight and ocular tomography on day 1 as the control values. Pupil diameters were re-measured after injecting 0.5 cc saline to the SHAM group, and autologous arterial blood into the cisterna magna of the study group. After 3 weeks, the brain, superior cervical sympathetic ganglia and ciliary ganglia were extracted with peripheral tissues bilaterally and examined histopathologically. Pupil diameters were compared with neuron densities of the sympathetic ganglia and ciliary ganglia which were examined using stereological methods. Baseline values were; normal pupil diameter 7.180±620 ?m and mean neuron density of the superior cervical sympathetic ganglia 6.321±510/mm3, degenerated neuron density of ciliary ganglia was 5±2/mm3 after histopathological examination in the control group. These values were measured as 6.850±578 ?m, 5.950±340/mm3 and 123±39/mm3 in the SHAM group and 9.910±840 ?m, 7.950±764/mm3 and 650±98/mm3 in the study group. A linear relationship was determined between neuron density of the superior cervical sympathetic ganglia and pupil diameters (p < 0.005). Degenerated ciliary ganglia neuron density had an inverse effect on pupil diameters in all groups (p < 0.0001). Highly degenerated neuron density of the ciliary ganglion is not responsible for pupil dilatation owing to parasympathetic pupilloconstrictor palsy, but high neuron density of the pupillodilatatory superior cervical sympathetic ganglia should be considered an important factor for pupil dilatation.

  17. Surface resistances of 5-cm-diameter YBCO films prepared by MOD for microwave applications

    International Nuclear Information System (INIS)

    Manabe, T.; Sohma, M.; Yamaguchi, I.; Tsukada, K.; Kondo, W.; Kamiya, K.; Tsuchiya, T.; Mizuta, S.; Kumagai, T.

    2006-01-01

    Large-area high-T c superconducting films with low surface resistances R s are required for use in microwave applications such as band pass filters. In this paper, preparation of 5-cm-diameter YBCO films on LaAlO 3 (LAO) and CeO 2 -buffered sapphire (CbS) substrates by metalorganic deposition (MOD) using a fluorine-free coating solution and their superconducting properties are described. The optimum firing conditions for YBCO films greatly depend on the substrate materials; a heating rate at ramp as high as 200 deg. C /min is necessary for films on LAO whereas a lower heating rate, e.g., 20 deg. C /min, is required for films on CbS. Accordingly, the suitable furnace systems for these substrates have been varied. As a result, a YBCO film with high J c (77 K) of 2.7 MA/cm 2 and a low R s (12 GHz, 77 K) of 0.54 mΩ was prepared on LAO by using an infrared image furnace. On the other hand, a YBCO film with a higher J c (77 K) of 4.0 MA/cm 2 and the same R s (12 GHz, 77 K) of 0.54 mΩ was prepared on CbS by using a tube furnace

  18. Study of tube diameter effect on the burnout

    International Nuclear Information System (INIS)

    Levitan, L.L.; Lantsman, F.P.; Dedneva, E.I.

    1981-01-01

    Effect of a tube diameter d on boundary steam content Xsub(b) is experimentally investigated during unwashed liquid wall film drying in the disperse-ring flow regime. For this purpose systematical experimental investigations of the burnout of the second kind in tubes with diameters of 4, 6 and 12 mm have been carried out as well as the other data relating to burnout in tubes with diameter from 4 to 40 mm are used. The investigations have been carried out at water and steam pressures of 4.9-13.7 MPa and mass velocities from 750 to 5000 kg/m 2 xs. It is elucidated that increase in the tube diameter results in reducing the ranges of pressures and mass velocities at which Xsub(b) is independent of heat flux. Quantity dependence Xsub(b)=f(d) has been obtained as well. The best agreement with data from different experiments is observed when taking into account the effect of d on Xsub(b) by means of the following relation: Xsub(b) is proportional to dsup(-0.25). In this case divergence, as a rule, does not exceed 10% [ru

  19. Experimental investigation of the transverse modal instabilities onset in high power fully-aperiodic-large-pitch fiber lasers

    Science.gov (United States)

    Malleville, Marie-Alicia; Benoît, Aurélien; Dauliat, Romain; Leconte, Baptiste; Darwich, Dia; du Jeu, Rémi; Jamier, Raphaël.; Schwuchow, Anka; Schuster, Kay; Roy, Philippe

    2018-02-01

    Over the last decade, significant work has been carried out in order to increase the energy/peak power provided by fiber lasers. Indeed, new microstructured fibers with large (or very large) mode area cores (LMA) such as Distributed Mode Filtering (DMF) fibers and Large-Pitch Fibers (LPF) have been developed to address this concern. These technologies have allowed diffraction-limited emission with core diameters higher than 80 μm, and have state-of-the-art performances in terms of pulse energy or peak power while keeping an excellent spatial beam quality. Although these fibers were designed to reach high power levels while maintaining a single transverse mode propagation, power scaling becomes quickly limited by the onset of transverse modal instabilities (TMI). This effect suddenly arises when a certain average power threshold is exceeded, drastically degrading the emitted beam quality. In this work, we investigate the influence of the core dimensions and the refractive index mismatch between the active core and the background cladding material, on the TMI power threshold in rod-type Fully-Aperiodic-LPF. This fiber structure was specifically designed to enhance the higher-order modes (HOMs) delocalization out of the gain region and thus push further the onset of modal instabilities. Using a 400W pump diode at 976 nm, the power scaling, as well as the spatial beam quality and its temporal behavior were investigated in laser configuration, which theoretically provides a lower TMI power threshold than the amplifier one due to the lack of selective excitation of the fundamental mode.

  20. Interfacial area transport of bubbly flow in a small diameter pipe

    International Nuclear Information System (INIS)

    Hibiki, Takashi; Takamasa, Tomoji; Ishii, Mamoru

    2001-01-01

    In relation to the development of the interfacial area transport equation, this study focused on modeling of the interfacial area transport mechanism of vertical adiabatic air-water bubbly flows in a relatively small diameter pipe where the bubble size-to-pipe diameter ratio was relatively high and the radial motion of bubbles was restricted by the presence of the pipe wall. The sink term of the interfacial area concentration was modeled by considering wake entrainment as a possible bubble coalescence mechanism, whereas the source term was neglected by assuming negligibly small bubble breakup for low liquid velocity conditions based on visual observation. One-dimensional interfacial area transport equation with the derived sink term was evaluated by using five datasets of vertical adiabatic air-water bubbly flows measured in a 9.0 mm-diameter pipe (superficial gas velocity: 0.013-0.052 m/s, superficial liquid velocity: 0.58-1.0 m/s). The modeled interfacial area transport equation could reproduce the proper trend of the axial interfacial area transport and predict the measured interfacial area concentrations within an average relative deviation of ±11.1%. It was recognized that the present model would be promising for predicting the interfacial area transport of the examined bubbly flows. (author)

  1. Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6- to 10-Year Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Chih-Chien Hu

    2017-01-01

    Full Text Available Large-diameter head (LDH metal-on-metal (MoM total hip arthroplasty (THA has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years, the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.

  2. Divergent biparietal diameter growth rates in twin pregnancies.

    Science.gov (United States)

    Houlton, M C

    1977-05-01

    Twenty-eight twin pregnancies were monitored by serial ultrasonic cephalometry from 30 or 31 weeks' gestation. The rates of growth of the individual twins as determined by biparietal diameters were similar in 11 cases (39%) and divergent in 17 (61%). When the rates of growth were divergent, the lesser rate was always below the mean for singleton pregnancies, and the incidence of small-for-gestational-age babies was 18 of 34 (53%). It was apparent that the greater the difference in biparietal diameters within the 2 weeks preceding delivery, the higher the risk of a small-for-gestation-age baby being delivered. No comment could be made on the growth rate prior to 28 weeks except that at diagnosis there was little or no difference in biparietal diameters.

  3. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  4. Effects of successive tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs.

    Science.gov (United States)

    de Mello Souza, Carlos Henrique; Reinero, Carol R

    2016-06-01

    OBJECTIVE To evaluate the effects of successive large-segment tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs. ANIMALS 5 adult Beagles. PROCEDURES Right lateral radiographs were obtained for all dogs and used to measure tracheal length. Dogs were then euthanized, and successive segmental tracheal resections (intervals of 10% from 20% to 50% of the tracheal length), each of which was followed by anastomosis, were performed in each cadaver. Tracheobronchoscopy was performed before the first tracheal resection and after each of the anastomoses to evaluate tracheal diameter and changes in position of lobar bronchi. RESULTS Tracheal diameter was minimally affected by resections up to 50% of the tracheal length. Diameter of the trachea and position of bronchi were not affected by resection of 20% of the tracheal length. Changes in the position of various lobar bronchi were detected after resection of 30% of the tracheal length. CONCLUSIONS AND CLINCIAL RELEVANCE In this study, tracheal resections of 20% of the tracheal length were accommodated, possibly as a result of stretching of the annular ligament. Resections of ≥ 30% of the tracheal length altered the position of lobar bronchi. Clinical effects, if any, attributable to these changes in bronchial position remain to be elucidated.

  5. Mixed-effects height–diameter models for ten conifers in the inland ...

    African Journals Online (AJOL)

    To demonstrate the utility of mixed-effects height–diameter models when conducting forest inventories, mixedeffects height–diameter models are presented for several commercially and ecologically important conifers in the inland Northwest of the USA. After obtaining height–diameter measurements from a plot/stand of ...

  6. Instructional Leadership Responsibilities of Assistant Principals in Large Texas High Schools

    Science.gov (United States)

    Howard-Schwind, Michelle

    2010-01-01

    The purpose of this study was to determine the extent secondary assistant principals in large Texas high schools demonstrate behaviors consistent with what the literature describes as instructional leadership. Three hundred seventy principals and assistant principals of large Texas high schools participated in this study. The Principal…

  7. Synthesis of uniform CdS nanowires in high yield and its single nanowire electrical property

    International Nuclear Information System (INIS)

    Yan Shancheng; Sun Litao; Qu Peng; Huang Ninping; Song Yinchen; Xiao Zhongdang

    2009-01-01

    Large-scale high quality CdS nanowires with uniform diameter were synthesized by using a rapid and simple solvothermal route. Field emission scan electron microscopy (FESEM) and transmission electron microscopy (TEM) images show that the CdS nanowires have diameter of about 26 nm and length up to several micrometres. High resolution TEM (HRTEM) study indicates the single-crystalline nature of CdS nanowires with an oriented growth along the c-axis direction. The optical properties of the products were characterized by UV-vis absorption spectra, photoluminescence spectra and Raman spectra. The resistivity, electron concentration and electron mobility of single NW are calculated by fitting the symmetric I-V curves measured on single NW by the metal-semiconductor-metal model based on thermionic field emission theory. - Graphical abstract: Large-scale high quality CdS nanowires (NWs) with uniform diameter were synthesized by using a rapid and simple solvothermal route. The reaction time is reduced to 2 h, comparing to other synthesis which needed long reaction time up to 12 h. In addition, the as-prepared CdS nanowires have more uniform diameter and high yield. More importantly, the I-V curve of present single CdS nanowire has a good symmetric characteristic as expected by the theory.

  8. DETEKSI DIAMETER TUMOR PADA KULIT MENGGUNAKAN SEGMENTASI CITRA BERDASARKAN KARAKTERISTIK ABCDE

    Directory of Open Access Journals (Sweden)

    Wuwanjie Septian

    2016-09-01

    ABSTRAK Kanker kulit merupakan pertumbuhan sel kulit abnormal yang tidak dapat dikendalikan dan pada stadium lanjut dapat mengakibatkan kematian. Menemukan penyakit ini sedini mungkin merupakan salah satu cara untuk menghindari kecacatan maupun kemungkinan terburuk. Karena letaknya dipermukaan kulit, akan mudah bagi siapa saja untuk mengenali sendiri kanker kulit. Deteksi dini kanker kulit dalam bidang dermatologi, dapat dideteksi berdasarkan karakteristik Asymmetrical Shape, Border, Color, Diameter, Evolution (ABCDE. Dalam penelitian ini, deteksi dini difokuskan pada identifikasi diameter pada 30 citra nevus. Metode penelitian berupa pengolahan citra nevus dengan melakukan konversi citra menjadi citra HSI lalu diubah menjadi citra biner, selanjutnya dilakukan tahap segmentasi menggunakan filter median, proses rekonstruksi morfologi dan pada tahap akhir dilakukan deteksi tepi dengan menggunakan operator sobel. Proses deteksi tepi akan mempermudah menghitung nilai luas diameter nevus. Hasil penelitian deteksi dini kanker kulit terhadap 30 citra nevus, diperoleh hasil bahwa metode pengolahan citra yang diusulkan dapat mendeteksi diameter nevus dan berhasil mengidentifikasi citra tersebut sebagai 26 citra memiliki luas diameter nevus yang diidentifikasi sebagai tumor jinak dan 4 citra nevus yang memiliki diameter > 6 mm dan dinyatakan sebagai tumor melanoma. Kata Kunci: Nevus, Melanoma, Segmentasi, Deteksi Diameter

  9. Generalized height-diameter models for Populus tremula L. stands

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... and stand density) into the base height-diameter models increased the accuracy of prediction for P. tremula. .... parameter estimates compared with those obtained with ... using coefficient of determination for non-linear regression (. 2. R ), ..... stochastic height-diameter model for maritime pine ecoregions in.

  10. Development of technique for estimating primary cooling system break diameter in predicting nuclear emergency event sequence

    International Nuclear Information System (INIS)

    Tatebe, Yasumasa; Yoshida, Yoshitaka

    2012-01-01

    If an emergency event occurs in a nuclear power plant, appropriate action is selected and taken in accordance with the plant status, which changes from time to time, in order to prevent escalation and mitigate the event consequences. It is thus important to predict the event sequence and identify the plant behavior resulting from the action taken. In predicting the event sequence during a loss-of-coolant accident (LOCA), it is necessary to estimate break diameter. The conventional method for this estimation is time-consuming, since it involves multiple sensitivity analyses to determine the break diameter that is consistent with the plant behavior. To speed up the process of predicting the nuclear emergency event sequence, a new break diameter estimation technique that is applicable to pressurized water reactors was developed in this study. This technique enables the estimation of break diameter using the plant data sent from the safety parameter display system (SPDS), with focus on the depressurization rate in the reactor cooling system (RCS) during LOCA. The results of LOCA analysis, performed by varying the break diameter using the MAAP4 and RELAP5/MOD3.2 codes, confirmed that the RCS depressurization rate could be expressed by the log linear function of break diameter, except in the case of a small leak, in which RCS depressurization is affected by the coolant charging system and the high-pressure injection system. A correlation equation for break diameter estimation was developed from this function and tested for accuracy. Testing verified that the correlation equation could estimate break diameter accurately within an error of approximately 16%, even if the leak increases gradually, changing the plant status. (author)

  11. Can ratio of the biggest tumor diameter to total tumor diameter be a new parameter in the differential diagnosis of agressive and favorable multifocal papillary thyroid microcarcinoma?

    Science.gov (United States)

    Tam, Abbas Ali; Özdemir, Didem; Çuhacı, Neslihan; Başer, Hüsniye; Dirikoç, Ahmet; Aydın, Cevdet; Yazgan, Aylin Kılıç; Ersoy, Reyhan; Çakır, Bekir

    2017-02-01

    In this study, we aimed to evaluate the usefulness of a new parameter -ratio of the biggest tumor diameter to total tumor diameter- for the differentiation of agressive and favorable papillary thyroid microcarcinomas (PTMC). The diameter of the biggest tumor focus was taken as the primary tumor diameter. Total tumor diameter was calculated as the sum of the maximal diameter of each lesion. Ratio of primary tumor diameter to total tumor diameter was defined as tumor diameter ratio (TDR). Positive and negative predictive value, sensitivity and specificity of TDR to predict capsular invasion, extrathyroidal extension (ETE) and lymph node metastasis (LNM) were determined. Mean TDR was significantly lower in multifocal PTMC patients with capsular invasion, ETE, lymphovascular invasion and LNM compared to patients without these features. The sensitivities of TDR for the detection of LNM, ETE and capsular invasion were 100%, 100% and 94.2%, respectively. Specificity of TDR was 86.2% for LNM, 88% for ETE and 94.7% for capsular invasion. Best cut off values of TDR that can predict capsular invasion, ETE and LNM in multifocal PTMC were 0.62, 0.57 and 0.56, respectively. Multifocal papillary thyroid carcinoma patients with capsular invasion, ETE and LNM had significantly lower mean TDR when compared to ones without these features. Decreased TDR was associated with capsular invasion, ETE and LNM in patients with multifocal PTMC and PTC. This new parameter might be particularly helpful for the detection of aggressive behavior in multifocal PTMCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Large shaft development test plan

    International Nuclear Information System (INIS)

    Krug, A.D.

    1984-03-01

    This test plan proposes the conduct of a large shaft development test at the Hanford site in support of the repository development program. The purpose and objective of the test plan is to obtain the information necessary to establish feasibility and to predict the performance of the drilling system used to drill large diameter shafts. The test plan is based upon drilling a 20 ft diameter shaft to a depth of 1,000 feet. The test plan specifies series of tests to evaluate the performance of the downhole assembly, the performance of the rig, and the ability of the system to cope with geologic hazards. The quality of the hole produced will also be determined. This test plan is considered to be preliminary in that it was prepared as input for the decision to determine if development testing is required in this area. Should the decision be made to proceed with development testing, this test plan shall be updated and revised. 6 refs., 2 figs., 3 tabs

  13. Brain Arterial Diameters as a Risk Factor for Vascular Events

    OpenAIRE

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-01-01

    Background Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Methods and Results Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, ca...

  14. Global climate change: Mitigation opportunities high efficiency large chiller technology

    Energy Technology Data Exchange (ETDEWEB)

    Stanga, M.V.

    1997-12-31

    This paper, comprised of presentation viewgraphs, examines the impact of high efficiency large chiller technology on world electricity consumption and carbon dioxide emissions. Background data are summarized, and sample calculations are presented. Calculations show that presently available high energy efficiency chiller technology has the ability to substantially reduce energy consumption from large chillers. If this technology is widely implemented on a global basis, it could reduce carbon dioxide emissions by 65 million tons by 2010.

  15. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  16. Accuracy in radiosurgery: The influence of collimator diameters and arc weights on the dose distribution for single target

    Energy Technology Data Exchange (ETDEWEB)

    Plazas, M S [National Univ. of Colombia (Colombia); Lefkopoulus, D; Schlienger, M [Service de Radiotherapie, Hopital Tenon, Paris (France). Unite de Radiophysique; Merienne, L [Hopital Sainte Anne, Paris (France). Service de Neurochirurgie

    1996-08-01

    The dosimetric characteristics of mini-beams and dose distributions in beams used for radio surgery defer substantially from beams used in common radiotherapy. The aim of radio surgery is to deliver a high dose to the lesion in one single fraction, while minimizing the dose delivered to the surrounding normal brain tissue. This type of irradiation is performed with a number of continuous arcs located in various corneal (patient sitting) or sagittal (patient in a supine position) inclined planes using a linear accelerator. A treatment planning system should take into account a large number of irradiation parameters such as the collimator diameter, number of arcs, their angular positions, length and weight of the arcs. We analysed the influence of collimator diameters in the range of 6 to 20 mm using 15 MV X-rays and stereo-tactic irradiation of ellipsoidal inclined arterio venous malformations (AVMs) with a single isocenter. Special arc weights were used to obtain an optimized dose distribution with 13 arcs distributed over an angular sector of 120 deg. x 13 deg. In the two studies made we used 3 dimensional dosimetric calculations. The results were used for the treatment of patients and enabled the choice of the optimal irradiation configuration for each patient. (author). 10 refs, 9 figs.

  17. First indirect x-ray imaging tests with an 88-mm diameter single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Macrander, A. T. [Argonne

    2017-02-01

    Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

  18. Approach for growth of high-quality and large protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Hiroyoshi, E-mail: matsumura@chem.eng.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Sugiyama, Shigeru; Hirose, Mika; Kakinouchi, Keisuke; Maruyama, Mihoko; Murai, Ryota [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); Adachi, Hiroaki; Takano, Kazufumi [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Murakami, Satoshi [JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, Nagatsuta, Midori-ku, Yokohama 226-8501 (Japan); Mori, Yusuke; Inoue, Tsuyoshi [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan)

    2011-01-01

    Three crystallization methods, including crystallization in the presence of a semi-solid agarose gel, top-seeded solution growth (TSSG) and a large-scale hanging-drop method, have previously been presented. In this study, crystallization has been further evaluated in the presence of a semi-solid agarose gel by crystallizing additional proteins. A novel crystallization method combining TSSG and the large-scale hanging-drop method has also been developed. Three crystallization methods for growing large high-quality protein crystals, i.e. crystallization in the presence of a semi-solid agarose gel, top-seeded solution growth (TSSG) and a large-scale hanging-drop method, have previously been presented. In this study the effectiveness of crystallization in the presence of a semi-solid agarose gel has been further evaluated by crystallizing additional proteins in the presence of 2.0% (w/v) agarose gel, resulting in complete gelification with high mechanical strength. In TSSG the seed crystals are hung by a seed holder protruding from the top of the growth vessel to prevent polycrystallization. In the large-scale hanging-drop method, a cut pipette tip was used to maintain large-scale droplets consisting of protein–precipitant solution. Here a novel crystallization method that combines TSSG and the large-scale hanging-drop method is reported. A large and single crystal of lysozyme was obtained by this method.

  19. Why size matters: the interactive influences of tree diameter distribution and sap flow parameters on upscaled transpiration.

    Science.gov (United States)

    Berry, Z Carter; Looker, Nathaniel; Holwerda, Friso; Gómez Aguilar, León Rodrigo; Ortiz Colin, Perla; González Martínez, Teresa; Asbjornsen, Heidi

    2018-02-01

    In stands with a broad range of diameters, a small number of very large trees can disproportionately influence stand basal area and transpiration (Et). Sap flow-based Et estimates may be particularly sensitive to large trees due to nonlinear relationships between tree-level water use (Q) and tree diameter at breast height (DBH). Because Q is typically predicted on the basis of DBH and sap flow rates measured in a subset of trees and then summed to obtain Et, we assessed the relative importance of DBH and sap flow variables (sap velocity, Vs, and sapwood depth, Rs) in determining the magnitude of Et and its dependence on large trees in a tropical montane forest ecosystem. Specifically, we developed a data-driven simulation framework to vary the relationship between DBH and Vs and stand DBH distribution and then calculate Q, Et and the proportion of Et contributed by the largest tree in each stand. Our results demonstrate that variation in how Rs is determined in the largest trees can alter estimates up to 26% of Et while variation in how Vs is determined can vary results by up to 132%. Taken together, these results highlight a great need to expand our understanding of water transport in large trees as this hinders our ability to predict water fluxes accurately from stand to catchment scales. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Tracheomalacia treatment using a large-diameter, custom-made airway stent in a case with mounier-kuhn syndrome.

    Science.gov (United States)

    Ozdemir, Cengiz; Sökücü, Sinem Nedime; Karasulu, Levent; Altın, Sedat; Dalar, Levent

    2014-01-01

    Mounier-Kuhn Syndrome (MKS) is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and that disappeared after stent removal may be considered the main complication leading to stent removal. Continuous positive airway pressure therapy (CPAP) therapy was planned for the control of symptoms, which re-emerged after stent removal. This case is presented as an example that complications developing due to the stent as well as patient noncompliance may lead to stent removal, even when useful results are obtained from treatment of MKS.

  1. Method for varying the diameter of a beam of charged particles

    International Nuclear Information System (INIS)

    Ko, W.C.; Sawatzky, E.

    1977-01-01

    In the bombardment of targets with beams of charged particles, a method is described for varying and controlling the diameter of such beams by passing the beam through an envelope of conductive material. The envelope is spaced from and coaxial with the beam. A selected dc potential is applied to the envelope, and the beam diameter is controlled by changing this applied potential in a direction away from ground potential to increase the beam diameter or by changing the potential in a direction toward ground potential to decrease said beam diameter

  2. Experimental analysis of heat conduction in a high diameter ratio annular gap filled with a rarefied gas

    International Nuclear Information System (INIS)

    Chalabi, H; Lorenzini, M; Morini, G L; Saraceno, L; Boccardi, G; Celata, G P

    2012-01-01

    A first experimental attempt has been realized in order to measure the heat transfer between a heated platinum wire having a diameter (d) of 0.15 mm, disposed along the axis of a cylindrical shell in stainless steel having an inner diameter (D) of 100 mm, and air from atmospheric conditions down to 10 −3 mbar. Temperature differences between the wire and the external stainless steel cylindrical shell in the range of 50–125 K were imposed and the heat power transferred from the wire to the surround was measured as a function of the gas pressure. The experimental results demonstrates that for an accurate measurement of the heat conduction when the pressure goes down to 0.05 mbar is very important to be able to quantify accurately the radiative contribution which becomes predominant at low pressure. The main limitations of the test rig described in this paper have been analysed in order to highlight the modifications which can be suggested to obtain experimental results comparable with theoretical models.

  3. Large-diameter boring of rock bed by a reveres circulation drill; Ribasu sakyureshon doriru ni yoru daikokei ganban sakko

    Energy Technology Data Exchange (ETDEWEB)

    Sakae, S.; Torii, K. [Kajima Corp., Tokyo (Japan); Hoshino, S.; Motoyama, M.

    1995-09-25

    The Itojima Large Bridge is a road bridge of 675 m in the total length connecting together the Nagashima Island and the Itojima Island in the northwest district of Kagoshima Prefecture, having a central span of 260 m and comprising a 5-span-continuous PC cable stayed bridges and PC box girder bridges. The foundation of this bridge employs a multi-pillar type pile structure. The piling work was started in July, 1991 by a hole inset method in a severe working environment where the depth of water is 20 m, the range of the tides is 4 m, the speed of tidal current is 2 kt, the rock bed structure is complicated and the steep seabed is steeply inclined. This report describes the results of the execution of the reverse circulation drilling, which has a high general versatility in rock bed boring, using self-lifting barges and large working boats during the rock bed boring for the foundation piling for the construction of the Itojima Large Bridge. The report, especially, also introduces the details of the work that casing pipes were driven into a stable rock bed by a vibrojet method for the measure against the collapse of a bore wall which occurred during the boring work. 24 figs., 14 tabs.

  4. Adsorption of multilamellar tubes with a temperature tunable diameter at the air/water interface.

    Science.gov (United States)

    Fameau, Anne-Laure; Douliez, Jean-Paul; Boué, François; Ott, Frédéric; Cousin, Fabrice

    2011-10-15

    The ethanolamine salt of 12-hydroxy stearic acid is known to form tubes having a temperature tunable diameter. Here, we study the behavior of those tubes at the air/water interface by using Neutron Reflectivity. We observed that tubes indeed adsorbed at this interface below a fatty acid monolayer and exhibit the same temperature behavior as in bulk. There is however a peculiar behavior at around 50 °C for which the increase of the diameter of the tubes at the interface yields an unfolding of those tubes into a multilamellar layer. Upon further heating, the tubes re-fold and their diameter re-decreases after which they melt into micelles as observed in the bulk. All structural transitions at the interface are nevertheless reversible. This provides to the system a high interest for its interfacial properties because the structure at the air/water interface can be tuned easily by the temperature. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Gamma Knife radiosurgery for large vestibular schwannomas greater than 3 cm in diameter.

    Science.gov (United States)

    Huang, Cheng-Wei; Tu, Hsien-Tang; Chuang, Chun-Yi; Chang, Cheng-Siu; Chou, Hsi-Hsien; Lee, Ming-Tsung; Huang, Chuan-Fu

    2018-05-01

    OBJECTIVE Stereotactic radiosurgery (SRS) is an important alternative management option for patients with small- and medium-sized vestibular schwannomas (VSs). Its use in the treatment of large tumors, however, is still being debated. The authors reviewed their recent experience to assess the potential role of SRS in larger-sized VSs. METHODS Between 2000 and 2014, 35 patients with large VSs, defined as having both a single dimension > 3 cm and a volume > 10 cm 3 , underwent Gamma Knife radiosurgery (GKRS). Nine patients (25.7%) had previously undergone resection. The median total volume covered in this group of patients was 14.8 cm 3 (range 10.3-24.5 cm 3 ). The median tumor margin dose was 11 Gy (range 10-12 Gy). RESULTS The median follow-up duration was 48 months (range 6-156 months). All 35 patients had regular MRI follow-up examinations. Twenty tumors (57.1%) had a volume reduction of greater than 50%, 5 (14.3%) had a volume reduction of 15%-50%, 5 (14.3%) were stable in size (volume change 3 cm and a volume > 10 cm 3 and tolerable mass effect can be managed satisfactorily with GKRS. Tumor volume ≥ 15 cm 3 is a significant factor predicting poor tumor control following GKRS.

  6. Relationship between the tensile strengths and diameters of human umbilical cords.

    Science.gov (United States)

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-05-01

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. Diameter-dependent hydrophobicity in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kyakuno, Haruka, E-mail: h-kyakuno@kanagawa-u.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Fukasawa, Mamoru; Ichimura, Ryota; Nakai, Yusuke; Maniwa, Yutaka, E-mail: maniwa@phys.se.tmu.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Matsuda, Kazuyuki [Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Miyata, Yasumitsu [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); PRESTO, JST, Kawaguchi 332-0012 (Japan); Saito, Takeshi [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2016-08-14

    Single-wall carbon nanotubes (SWCNTs) are a good model system that provides atomically smooth nanocavities. It has been reported that water-SWCNTs exhibit hydrophobicity depending on the temperature T and the SWCNT diameter D. SWCNTs adsorb water molecules spontaneously in their cylindrical pores around room temperature, whereas they exhibit a hydrophilic-hydrophobic transition or wet-dry transition (WDT) at a critical temperature T{sub wd} ≈ 220-230 K and above a critical diameter D{sub c} ≈ 1.4-1.6 nm. However, details of the WDT phenomenon and its mechanism remain unknown. Here, we report a systematic experimental study involving X-ray diffraction, optical microscopy, and differential scanning calorimetry. It is found that water molecules inside thick SWCNTs (D > D{sub c}) evaporate and condense into ice Ih outside the SWCNTs at T{sub wd} upon cooling, and the ice Ih evaporates and condenses inside the SWCNTs upon heating. On the other hand, residual water trapped inside the SWCNTs below T{sub wd} freezes. Molecular dynamics simulations indicate that upon lowering T, the hydrophobicity of thick SWCNTs increases without any structural transition, while the water inside thin SWCNTs (D < D{sub c}) exhibits a structural transition, forming an ordered ice. This ice has a well-developed hydrogen bonding network adapting to the cylindrical pores of the SWCNTs. Thus, the unusual diameter dependence of the WDT is attributed to the adaptability of the structure of water to the pore dimension and shape.

  8. Measurement error in CT assessment of appendix diameter

    Energy Technology Data Exchange (ETDEWEB)

    Trout, Andrew T.; Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Department of Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-12-15

    Appendiceal diameter continues to be cited as an important criterion for diagnosis of appendicitis by computed tomography (CT). To assess sources of error and variability in appendiceal diameter measurements by CT. In this institutional review board-approved review of imaging and medical records, we reviewed CTs performed in children <18 years of age between Jan. 1 and Dec. 31, 2010. Appendiceal diameter was measured in the axial and coronal planes by two reviewers (R1, R2). One year later, 10% of cases were remeasured. For patients who had multiple CTs, serial measurements were made to assess within patient variability. Measurement differences between planes, within and between reviewers, within patients and between CT and pathological measurements were assessed using correlation coefficients and paired t-tests. Six hundred thirty-one CTs performed in 519 patients (mean age: 10.9 ± 4.9 years, 50.8% female) were reviewed. Axial and coronal measurements were strongly correlated (r = 0.92-0.94, P < 0.0001) with coronal plane measurements significantly larger (P < 0.0001). Measurements were strongly correlated between reviewers (r = 0.89-0.9, P < 0.0001) but differed significantly in both planes (axial: +0.2 mm, P=0.003; coronal: +0.1 mm, P=0.007). Repeat measurements were significantly different for one reviewer only in the axial plane (0.3 mm difference, P<0.05). Within patients imaged multiple times, measured appendix diameters differed significantly in the axial plane for both reviewers (R1: 0.5 mm, P = 0.031; R2: 0.7 mm, P = 0.022). Multiple potential sources of measurement error raise concern about the use of rigid diameter cutoffs for the diagnosis of acute appendicitis by CT. (orig.)

  9. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  10. Development of large high current density superconducting solenoid magnets for use in high energy physics experiments

    International Nuclear Information System (INIS)

    Green, M.A.

    1977-05-01

    The development of a unique type of large superconducting solenoid magnet, characterized by very high current density windings and a two-phase helium tubular cooling system is described. The development of the magnet's conceptual design and the construction of two test solenoids are described. The successful test of the superconducting coil and its tubular cooling refrigeration system is presented. The safety, environmental and economic impacts of the test program on future developments in high energy physics are shown. Large solid angle particle detectors for colliding beam physics will analyze both charged and neutral particles. In many cases, these detectors will require neutral particles, such as gamma rays, to pass through the magnet coil with minimum interaction. The magnet coils must be as thin as possible. The use of superconducting windings allows one to minimize radiation thickness, while at the same time maximizing charged particle momentum resolution and saving substantial quantities of electrical energy. The results of the experimental measurements show that large high current density solenoid magnets can be made to operate at high stored energies. The superconducting magnet development described has a positive safety and environmental impact. The use of large high current density thin superconducting solenoids has been proposed in two high energy physics experiments to be conducted at the Stanford Linear Accelerator Center and Cornell University as a result of the successful experiments described

  11. Bipartite Diametrical Graphs of Diameter 4 and Extreme Orders

    Directory of Open Access Journals (Sweden)

    Salah Al-Addasi

    2008-01-01

    in which this upper bound is attained, this graph can be viewed as a generalization of the Rhombic Dodecahedron. Then we show that for any ≥2, the graph (2,2 is the unique (up to isomorphism bipartite diametrical graph of diameter 4 and partite sets of cardinalities 2 and 2, and hence in particular, for =3, the graph (6,8 which is just the Rhombic Dodecahedron is the unique (up to isomorphism bipartite diametrical graph of such a diameter and cardinalities of partite sets. Thus we complete a characterization of -graphs of diameter 4 and cardinality of the smaller partite set not exceeding 6. We prove that the neighborhoods of vertices of the larger partite set of (2,2 form a matroid whose basis graph is the hypercube . We prove that any -graph of diameter 4 is bipartite self complementary, thus in particular (2,2. Finally, we study some additional properties of (2,2 concerning the order of its automorphism group, girth, domination number, and when being Eulerian.

  12. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  13. Position measurement of the direct drive motor of Large Aperture Telescope

    Science.gov (United States)

    Li, Ying; Wang, Daxing

    2010-07-01

    Along with the development of space and astronomy science, production of large aperture telescope and super large aperture telescope will definitely become the trend. It's one of methods to solve precise drive of large aperture telescope using direct drive technology unified designed of electricity and magnetism structure. A direct drive precise rotary table with diameter of 2.5 meters researched and produced by us is a typical mechanical & electrical integration design. This paper mainly introduces position measurement control system of direct drive motor. In design of this motor, position measurement control system requires having high resolution, and precisely aligning the position of rotor shaft and making measurement, meanwhile transferring position information to position reversing information corresponding to needed motor pole number. This system has chosen high precision metal band coder and absolute type coder, processing information of coders, and has sent 32-bit RISC CPU making software processing, and gained high resolution composite coder. The paper gives relevant laboratory test results at the end, indicating the position measurement can apply to large aperture telescope control system. This project is subsidized by Chinese National Natural Science Funds (10833004).

  14. The development of a prototype facility for a large diameter vertical axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    A proposal is made in this document for the design, construction, assembly and test of a demonstration wind turbine generator system. The specific objective of the program will be to demonstrate that the proposed system satisfies the need for cheap power generation at those remote meteorological stations which currently rely exclusively on fossil fuel that must be transported to the site at great cost. It intends to demonstrate that a large vertical axis wind turbine system is within the current state-of-art, is practical and is economically attractive. The program will include a conceptual design phase, a detail design phase, a construction and assembly phase at a selected site and a demonstration phase during which data will be gathered on operation at this large scale. A theory of operation of the proposed design is included. 4 refs., 3 figs.

  15. Variations in eyeball diameters of the healthy adults.

    Science.gov (United States)

    Bekerman, Inessa; Gottlieb, Paul; Vaiman, Michael

    2014-01-01

    The purpose of the current research was to reevaluate the normative data on the eyeball diameters. Methods. In a prospective cohort study, the CT data of consecutive 250 adults with healthy eyes were collected and analyzed, and sagittal, transverse, and axial diameters of both eyeballs were measured. The data obtained from the left eye and from the right eye were compared. The correlation analysis was performed with the following variables: orbit size, gender, age, and ethnic background. Results. We did not find statistically significant differences correlated with gender of the patients and their age. The right eyeball was slightly smaller than the left one but this difference was statistically insignificant (P = 0.17). We did not find statistically significant differences of the eyeball sizes among the ethnicities we dealt with. Strong correlation was found between the transverse diameter and the width of the orbit (r = 0.88). Conclusion. The size of a human adult eye is approximately 24.2 mm (transverse) × 23.7 mm (sagittal) × 22.0-24.8 mm (axial) with no significant difference between sexes and age groups. In the transverse diameter, the eyeball size may vary from 21 mm to 27 mm. These data might be useful in ophthalmological, oculoplastic, and neurological practice.

  16. Shiitake mushroom production on small diameter oak logs in Ohio

    Science.gov (United States)

    S.M. Bratkovich

    1991-01-01

    Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.

  17. Tracheomalacia Treatment Using a Large-Diameter, Custom-Made Airway Stent in a Case with Mounier-Kuhn Syndrome

    Directory of Open Access Journals (Sweden)

    Cengiz Özdemir

    2014-01-01

    Full Text Available Mounier-Kuhn Syndrome (MKS is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and that disappeared after stent removal may be considered the main complication leading to stent removal. Continuous positive airway pressure therapy (CPAP therapy was planned for the control of symptoms, which re-emerged after stent removal. This case is presented as an example that complications developing due to the stent as well as patient noncompliance may lead to stent removal, even when useful results are obtained from treatment of MKS.

  18. Highly uniform parallel microfabrication using a large numerical aperture system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zi-Yu; Su, Ya-Hui, E-mail: ustcsyh@ahu.edu.cn, E-mail: dongwu@ustc.edu.cn [School of Electrical Engineering and Automation, Anhui University, Hefei 230601 (China); Zhang, Chen-Chu; Hu, Yan-Lei; Wang, Chao-Wei; Li, Jia-Wen; Chu, Jia-Ru; Wu, Dong, E-mail: ustcsyh@ahu.edu.cn, E-mail: dongwu@ustc.edu.cn [CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026 (China)

    2016-07-11

    In this letter, we report an improved algorithm to produce accurate phase patterns for generating highly uniform diffraction-limited multifocal arrays in a large numerical aperture objective system. It is shown that based on the original diffraction integral, the uniformity of the diffraction-limited focal arrays can be improved from ∼75% to >97%, owing to the critical consideration of the aperture function and apodization effect associated with a large numerical aperture objective. The experimental results, e.g., 3 × 3 arrays of square and triangle, seven microlens arrays with high uniformity, further verify the advantage of the improved algorithm. This algorithm enables the laser parallel processing technology to realize uniform microstructures and functional devices in the microfabrication system with a large numerical aperture objective.

  19. Geometric interpretation of the ratio of overall diameter to rim crest diameter for lunar and terrestrial craters.

    Science.gov (United States)

    Siegal, B. S.; Wickman, F. E.

    1973-01-01

    An empirical linear relationship has been established by Pike (1967) between the overall diameter and the rim crest diameter for rimmed, flat-floored as well as bowl-shaped, lunar and terrestrial craters formed by impact and explosion. A similar relationship for experimentally formed fluidization craters has been established by Siegal (1971). This relationship is examined in terms of the geometry of the crater and the slope angles of loose materials. The parameter varies from 1.40 to 1.65 and is found to be dependent on mean interior flat floor radius, exterior and interior rim slope angles, angle of aperture of the crater cone, and the volume fraction of crater void accounted for in the rim. The range of the observed parameter can be understood in terms of simple crater geometry by realistic values of the five parameters.

  20. Strong diameter-dependence of nanowire emission coupled to waveguide modes

    Energy Technology Data Exchange (ETDEWEB)

    Dam, Dick van, E-mail: a.d.v.dam@tue.nl; Haverkort, Jos E. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Abujetas, Diego R.; Sánchez-Gil, José A. [Instituto de Estructura de la Materia (IEM-CSIC), Consejo Superior de Investigaciones Científicas Serrano, 121, 28006 Madrid (Spain); Bakkers, Erik P. A. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Gómez Rivas, Jaime, E-mail: j.gomezrivas@differ.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Dutch Institute for Fundamental Energy Research DIFFER, P.O. Box 6336, 5600 HH Eindhoven (Netherlands)

    2016-03-21

    The emission from nanowires can couple to waveguide modes supported by the nanowire geometry, thus governing the far-field angular pattern. To investigate the geometry-induced coupling of the emission to waveguide modes, we acquire Fourier microscopy images of the photoluminescence of nanowires with diameters ranging from 143 to 208 nm. From the investigated diameter range, we conclude that a few nanometers difference in diameter can abruptly change the coupling of the emission to a specific mode. Moreover, we observe a diameter-dependent width of the Gaussian-shaped angular pattern in the far-field emission. This dependence is understood in terms of interference of the guided modes, which emit at the end facets of the nanowire. Our results are important for the design of quantum emitters, solid state lighting, and photovoltaic devices based on nanowires.

  1. Computing Diameter in the Streaming and Sliding-Window Models (Preprint)

    National Research Council Canada - National Science Library

    Feigenbaum, Joan; Kannan, Sampath; Zhang, Jian

    2002-01-01

    We investigate the diameter problem in the streaming and sliding-window models. We show that, for a stream of n points or a sliding window of size n, any exact algorithm for diameter requires Omega(n) bits of space...

  2. Determination of pore diameter from rejection measurements with a mixture of oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza-Gomez, Heriberto; Rogel-Hernandez, Eduardo [Universidad Autonoma de Baja California-Tijuana, Facultad de Ciencias Quimicas e Ingenieria, Tijuana, BC (Mexico); Lin, Shui Wai [Centro de Graduados e Investigacion del Instituto Tecnologico de Tijuana, Apdo. Postal 1166, Tijuana, BC (Mexico)

    2005-04-01

    This paper present a method to determine pore diameters and effective transport through membranes using a mixture of oligosaccharides. The results are compared with the Maxwell-Stefan equations. The partition coefficients of the solutes are a function of the pore diameter according to the Ferry equation. Thus, with the pore diameter as the only unknown parameter, rejection is described and the pore diameter is obtained by a Marquardt-Levenberg optimization procedure. (orig.)

  3. Determination of the luminal diameter of the radial artery in man by high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1990-01-01

    measurements. By comparing the diameter of the reference object either filled with water or blood at 37 degrees C, the ultrasound velocity in human blood at 37 degrees C was calculated to be 1605 m/s. The intraobserver repeatability coefficients of in-vivo measurements of the radial artery in man were...... in the same range, whether measurements were repeated after 30 min (14%) or from day to day (12%). The interobserver repeatability coefficient was acceptable (15%) when the site of measurements was marked, whereas measurements without a mark resulted in a repeatability coefficient of 24%. The intravenous...

  4. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. A large spherical HPD for a novel deep-sea neutrino experiment

    International Nuclear Information System (INIS)

    Ball, A.E.; Braem, A.; Camilleri, L.; Catinaccio, A.; Chelkov, G.; Dydak, F.; Elagin, A.; Frandsen, P.; Grant, A.; Gostkin, M.; Guskov, A.; Joram, C.; Krumshteyn, Z.; Lustermann, W.; Postema, H.; Price, M.; Rovelli, T.; Schinzel, D.; Seguinot, J.; Valenti, G.; Voss, R.; Wotschack, J.; Zhemchugov, A.

    2005-01-01

    An underwater neutrino experiment has been proposed which provides precise measurements of the neutrino mixing parameters θ 23 and Δm 23 2 and permits an increase of sensitivity for the small angle θ 13 by more than one order of magnitude. A Cherenkov detector of about 1.5Mt active mass, deployed in the Gulf of Taranto, utilizes the CNGS beam in off-axis configuration which represents an essentially mono-energetic source of muon neutrinos. A unique feature of the experiment is the possibility to move the detector and therefore exploit different baselines around 1200km where the oscillation pattern is fully developed. The conceptual detector design consists of O(30,000) large area and acceptance photosensors arranged in a matrix of ∼300x300m 2 size. Hybrid photon detectors are considered as promising candidates as they provide clean signal characteristics and uniform collection efficiency. We discuss the design and expected performance of a large spherical HPD with 380mm diameter, which is housed in a high-pressure glass container. A scaled prototype HPD of 208mm diameter is currently under development using the existing CERN HPD facility

  6. Hot seeding using large Y-123 seeds

    International Nuclear Information System (INIS)

    Scruggs, S J; Putman, P T; Zhou, Y X; Fang, H; Salama, K

    2006-01-01

    There are several motivations for increasing the diameter of melt textured single domain discs. The maximum magnetic field produced by a trapped field magnet is proportional to the radius of the sample. Furthermore, the availability of trapped field magnets with large diameter could enable their use in applications that have traditionally been considered to require wound electromagnets, such as beam bending magnets for particle accelerators and electric propulsion. We have investigated the possibility of using large area epitaxial growth instead of the conventional point nucleation growth mechanism. This process involves the use of large Y123 seeds for the purpose of increasing the maximum achievable Y123 single domain size. The hot seeding technique using large Y-123 seeds was employed to seed Y-123 samples. Trapped field measurements indicate that single domain samples were indeed grown by this technique. Microstructural evaluation indicates that growth can be characterized by a rapid nucleation followed by the usual peritectic grain growth which occurs when large seeds are used. Critical temperature measurements show that no local T c suppression occurs in the vicinity of the seed. This work supports the suggestion of using an iterative method for increasing the size of Y-123 single domains that can be grown

  7. Transport of large particles released in a nuclear accident

    International Nuclear Information System (INIS)

    Poellaenen, R.; Toivonen, H.; Lahtinen, J.; Ilander, T.

    1995-10-01

    Highly radioactive particulate material may be released in a nuclear accident or sometimes during normal operation of a nuclear power plant. However, consequence analyses related to radioactive releases are often performed neglecting the particle nature of the release. The properties of the particles have an important role in the radiological hazard. A particle deposited on the skin may cause a large and highly non-uniform skin beta dose. Skin dose limits may be exceeded although the overall activity concentration in air is below the level of countermeasures. For sheltering purposes it is crucial to find out the transport range, i.e. the travel distance of the particles. A method for estimating the transport range of large particles (aerodynamic diameter d a > 20 μm) in simplified meteorological conditions is presented. A user-friendly computer code, known as TROP, is developed for fast range calculations in a nuclear emergency. (orig.) (23 refs., 13 figs.)

  8. Transport of large particles released in a nuclear accident

    Energy Technology Data Exchange (ETDEWEB)

    Poellaenen, R; Toivonen, H; Lahtinen, J; Ilander, T

    1995-10-01

    Highly radioactive particulate material may be released in a nuclear accident or sometimes during normal operation of a nuclear power plant. However, consequence analyses related to radioactive releases are often performed neglecting the particle nature of the release. The properties of the particles have an important role in the radiological hazard. A particle deposited on the skin may cause a large and highly non-uniform skin beta dose. Skin dose limits may be exceeded although the overall activity concentration in air is below the level of countermeasures. For sheltering purposes it is crucial to find out the transport range, i.e. the travel distance of the particles. A method for estimating the transport range of large particles (aerodynamic diameter d{sub a} > 20 {mu}m) in simplified meteorological conditions is presented. A user-friendly computer code, known as TROP, is developed for fast range calculations in a nuclear emergency. (orig.) (23 refs., 13 figs.).

  9. Orientationally invariant indices of axon diameter and density from diffusion MRI

    DEFF Research Database (Denmark)

    Alexander, Daniel C; Hubbard, Penny L; Hall, Matt G

    2010-01-01

    tensor imaging. Orientational invariance allows for combination with tractography and presents new opportunities for mapping brain connectivity and quantifying disease processes. The technique uses a four-compartment tissue model combined with an optimized multishell high-angular-resolution pulsed...... to natural axon diameter distributions for the first time with both specialist and clinical hardware. This demonstration motivates further refinement, validation, and evaluation of the precise nature of the indices and the influence of potential confounds....

  10. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    International Nuclear Information System (INIS)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E.; Nugent, C.; Cutri, R. M.; Wright, E. L.; Bauer, J. M.; Grav, T.; Sonnett, S.

    2017-01-01

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey, as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.

  11. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    Energy Technology Data Exchange (ETDEWEB)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E. [Jet Propulsion Laboratory/California Institute of Technology, 4800 Oak Grove Drive, MS 183-301, Pasadena, CA 91109 (United States); Nugent, C.; Cutri, R. M. [California Institute of Technology, Infrared Processing and Analysis Center, 1200 California Boulevard, Pasadena, CA 91125 (United States); Wright, E. L. [University of California, Los Angeles, CA 90095 (United States); Bauer, J. M. [University of Maryland, College Park, MD 20742 (United States); Grav, T.; Sonnett, S., E-mail: Joseph.Masiero@jpl.nasa.gov [Planetary Science Institute, 1700 E Fort Lowell Road #106, Tucson, AZ 85719 (United States)

    2017-10-01

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey, as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.

  12. Origami Wheel Transformer: A Variable-Diameter Wheel Drive Robot Using an Origami Structure.

    Science.gov (United States)

    Lee, Dae-Young; Kim, Sa-Reum; Kim, Ji-Suk; Park, Jae-Jun; Cho, Kyu-Jin

    2017-06-01

    A wheel drive mechanism is simple, stable, and efficient, but its mobility in unstructured terrain is seriously limited. Using a deformable wheel is one of the ways to increase the mobility of a wheel drive robot. By changing the radius of its wheels, the robot becomes able to pass over not only high steps but also narrow gaps. In this article, we propose a novel design for a variable-diameter wheel using an origami-based soft robotics design approach. By simply folding a patterned sheet into a wheel shape, a variable-diameter wheel was built without requiring lots of mechanical parts and a complex assembly process. The wheel's diameter can change from 30 to 68 mm, and it is light in weight at about 9.7 g. Although composed of soft materials (fabrics and films), the wheel can bear more than 400 times its weight. The robot was able to change the wheel's radius in response to terrain conditions, allowing it to pass over a 50-mm gap when the wheel is shrunk and a 50-mm step when the wheel is enlarged.

  13. Eustachian tube diameter: Is it associated with chronic otitis media development?

    Science.gov (United States)

    Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet

    To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  15. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  16. High density high performance plasma with internal diffusion barrier in Large Helical Device

    International Nuclear Information System (INIS)

    Sakamoto, R.; Kobayashi, M.; Miyazawa, J.

    2008-10-01

    A attractive high density plasma operational regime, namely an internal diffusion barrier (IDB), has been discovered in the intrinsic helical divertor configuration on the Large Helical Device (LHD). The IDB which enables core plasma to access a high density/high pressure regime has been developed. It is revealed that the IDB is reproducibly formed by pellet fueling in the magnetic configurations shifted outward in major radius. Attainable central plasma density exceeds 1x10 21 m -3 . Central pressure reaches 1.5 times atmospheric pressure and the central β value becomes fairly high even at high magnetic field, i.e. β(0)=5.5% at B t =2.57 T. (author)

  17. LARGE-SCALE HYDROGEN PRODUCTION FROM NUCLEAR ENERGY USING HIGH TEMPERATURE ELECTROLYSIS

    International Nuclear Information System (INIS)

    O'Brien, James E.

    2010-01-01

    Hydrogen can be produced from water splitting with relatively high efficiency using high-temperature electrolysis. This technology makes use of solid-oxide cells, running in the electrolysis mode to produce hydrogen from steam, while consuming electricity and high-temperature process heat. When coupled to an advanced high temperature nuclear reactor, the overall thermal-to-hydrogen efficiency for high-temperature electrolysis can be as high as 50%, which is about double the overall efficiency of conventional low-temperature electrolysis. Current large-scale hydrogen production is based almost exclusively on steam reforming of methane, a method that consumes a precious fossil fuel while emitting carbon dioxide to the atmosphere. Demand for hydrogen is increasing rapidly for refining of increasingly low-grade petroleum resources, such as the Athabasca oil sands and for ammonia-based fertilizer production. Large quantities of hydrogen are also required for carbon-efficient conversion of biomass to liquid fuels. With supplemental nuclear hydrogen, almost all of the carbon in the biomass can be converted to liquid fuels in a nearly carbon-neutral fashion. Ultimately, hydrogen may be employed as a direct transportation fuel in a 'hydrogen economy.' The large quantity of hydrogen that would be required for this concept should be produced without consuming fossil fuels or emitting greenhouse gases. An overview of the high-temperature electrolysis technology will be presented, including basic theory, modeling, and experimental activities. Modeling activities include both computational fluid dynamics and large-scale systems analysis. We have also demonstrated high-temperature electrolysis in our laboratory at the 15 kW scale, achieving a hydrogen production rate in excess of 5500 L/hr.

  18. The Phoenix series large scale LNG pool fire experiments.

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, Richard B.; Jensen, Richard Pearson; Demosthenous, Byron; Luketa, Anay Josephine; Ricks, Allen Joseph; Hightower, Marion Michael; Blanchat, Thomas K.; Helmick, Paul H.; Tieszen, Sheldon Robert; Deola, Regina Anne; Mercier, Jeffrey Alan; Suo-Anttila, Jill Marie; Miller, Timothy J.

    2010-12-01

    The increasing demand for natural gas could increase the number and frequency of Liquefied Natural Gas (LNG) tanker deliveries to ports across the United States. Because of the increasing number of shipments and the number of possible new facilities, concerns about the potential safety of the public and property from an accidental, and even more importantly intentional spills, have increased. While improvements have been made over the past decade in assessing hazards from LNG spills, the existing experimental data is much smaller in size and scale than many postulated large accidental and intentional spills. Since the physics and hazards from a fire change with fire size, there are concerns about the adequacy of current hazard prediction techniques for large LNG spills and fires. To address these concerns, Congress funded the Department of Energy (DOE) in 2008 to conduct a series of laboratory and large-scale LNG pool fire experiments at Sandia National Laboratories (Sandia) in Albuquerque, New Mexico. This report presents the test data and results of both sets of fire experiments. A series of five reduced-scale (gas burner) tests (yielding 27 sets of data) were conducted in 2007 and 2008 at Sandia's Thermal Test Complex (TTC) to assess flame height to fire diameter ratios as a function of nondimensional heat release rates for extrapolation to large-scale LNG fires. The large-scale LNG pool fire experiments were conducted in a 120 m diameter pond specially designed and constructed in Sandia's Area III large-scale test complex. Two fire tests of LNG spills of 21 and 81 m in diameter were conducted in 2009 to improve the understanding of flame height, smoke production, and burn rate and therefore the physics and hazards of large LNG spills and fires.

  19. Experimental investigation of commercial small diameter dental implants in porcine mandibular segments.

    Science.gov (United States)

    Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph

    2017-02-01

    Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.

  20. Large-area and highly crystalline MoSe2 for optical modulator

    Science.gov (United States)

    Yin, Jinde; Chen, Hao; Lu, Wei; Liu, Mengli; Li, Irene Ling; Zhang, Min; Zhang, Wenfei; Wang, Jinzhang; Xu, Zihan; Yan, Peiguang; Liu, Wenjun; Ruan, Shuangchen

    2017-12-01

    Transition metal dichalcogenides (TMDs) have been successfully used as broadband optical modulator materials for pulsed fiber laser systems. However, the nonlinear optical absorptions of exfoliated TMDs are strongly limited by their nanoflakes morphology with uncontrollable lateral size and thickness. In this work, we provide an effective method to fully explore the nonlinear optical properties of MoSe2. Large-area and high quality lattice MoSe2 grown by chemical vapor deposition method was adopted as an optical modulator for the first time. The large-area MoSe2 shows excellent nonlinear optical absorption with a large modulation depth of 21.7% and small saturable intensity of 9.4 MW cm-2. After incorporating the MoSe2 optical modulator into fiber laser cavity as a saturable absorber, a highly stable Q-switching operation with single pulse energy of 224 nJ is achieved. The large-area MoSe2 possessing superior nonlinear optical properties compared to exfoliated nanoflakes affords possibility for the larger-area two-dimensional materials family as high performance optical devices.

  1. Is the biparietal diameter of fetuses in late gestation too variable to predict readiness for cesarean section in dogs?

    Science.gov (United States)

    De Cramer, K G M; Nöthling, J O

    2018-06-01

    Correct assessment of readiness for cesarean section is essential for timing elective cesarean section during late pregnancy in the bitch. In humans, biparietal diameter is sufficiently precise and accurate and used in a clinical setting daily. The objectives of this study were to determine whether fetal biparietal diameter in late gestation in the dog could be used to predict readiness for cesarean section by having reached a minimum cut-off value and to correlate the biparietal diameter to birth weight. The biparietal diameter of 208 puppies in 34 litters from 31 English bulldog bitches and 660 puppies in 78 litters from 70 Boerboel bitches were measured immediately after delivery by cesarean section, performed at full term, using digital calipers. At the same time the birth weight of the same 208 English bulldog puppies and 494 of the same Boerboel puppies in 59 litters from 54 bitches was measured by means of an electronic scale. With a cesarean section, all the puppies in a litter are delivered simultaneously and readiness for cesarean section must be determined for a litter. The minimum, median and maximum biparietal diameter varied from 21.1 to 47.8, 32.9 to 50.0 and 34.2-58.2 mm, respectively, among English bulldog litters and from 18.4 to 48.7, 35.5 to 49.7 and 39.8-54.3 mm among Boerboel litters. This large variation suggests that biparietal diameter is too variable within and among litters to be useful as a means of determining readiness for cesarean section. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Modulated convection at high frequencies and large modulation amplitudes

    International Nuclear Information System (INIS)

    Swift, J.B.; Hohenberg, P.C.

    1987-01-01

    Modulated Rayleigh-Benard convection is analyzed for high frequencies and large modulation amplitudes. The linear theory of Gershuni and Zhukhovitskii is generalized to the nonlinear domain, and a subcritical bifurcation to convection is found in agreement with the experiments of Niemela and Donnelly. The crossover between the high-frequency (''Stokes layer'') regime and the low-frequency regime studied previously is analyzed

  3. Recent progress in large grain/single crystal high RRR niobium

    International Nuclear Information System (INIS)

    Ganapati Rao Myneni; Peter Kneisel; Tadeu Carneiro; S.R. Agnew; F. Stevie

    2005-01-01

    High RRR bulk niobium Superconducting Radio Frequency (SRF) cavity technology is chosen for the International Linear Collider (ILC). The SRF community was convinced until now that fine grain polycrystalline RRR niobium sheets obtained via forging and cross rolling are essential for forming the SRF Cavities. However, it was recently discovered under a joint Reference Metals Company, Inc., - JLAB CRADA that large grain/single crystal RRR niobium sliced directly from ingots is highly ductile reaching 100 percent elongation. This discovery led to the successful fabrication of several SRF single and/or multi cell structures, formed with sliced RRR discs from the ingots, operating at 2.3, 1.5 and 1.3 GHz. This new exciting development is expected to offer high performance accelerator structures not only at reduced costs but also with simpler fabrication and processing conditions. As a result there is a renewed interest in the evaluation and understanding of the large grain and single crystal niobium with respect to their mechanical and physical properties as well as the oxidation behavior and the influence of impurities such as hydrogen and Ta. In this paper the results of many collaborative studies on large grain and single crystal high RRR niobium between JLAB, Universities and Industry are presented

  4. Bubble departure diameter in narrow rectangular channel under rolling condition

    Energy Technology Data Exchange (ETDEWEB)

    Xie, T.; Chen, B.; Yan, X.; Xu, J.; Huang, Y.; Xiao, Z. [Nuclear Power Inst. of China, Chengdu, Sichuan (China)

    2014-07-01

    Forced convective subcooled boiling flow experiments were conducted in a vertical upward narrow rectangular channel under rolling motion. A high-speed digital video camera was used to capture the dynamics of the bubble nucleation process. Bubble departure diameters were obtained from the images. A bubble departure model based on force balance analysis was proposed to predict the bubble departure size under rolling condition by considering the additional centrifugal, tangential and Coriolis force. The proposed model agreed well with the experimental data within the averaged relative deviation of 5%. (author)

  5. Comprehensive database of diameter-based biomass regressions for North American tree species

    Science.gov (United States)

    Jennifer C. Jenkins; David C. Chojnacky; Linda S. Heath; Richard A. Birdsey

    2004-01-01

    A database consisting of 2,640 equations compiled from the literature for predicting the biomass of trees and tree components from diameter measurements of species found in North America. Bibliographic information, geographic locations, diameter limits, diameter and biomass units, equation forms, statistical errors, and coefficients are provided for each equation,...

  6. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Science.gov (United States)

    Lee, Petry Y. R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung

    2012-10-01

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter ( D/ d = 2), spaced by a gap ratio 0.75 ( G/ D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 ≤ f e / f os ≤ 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f e / f os = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f e /3 (or f os ), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 ≤ f e / f os ≤ 3.22 is also not locked-on because the phase difference in the narrow wake excited at f e / f os = 2.93 and 3.07 changes significantly. Note f e and f os denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively.

  7. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Petry Y.R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung [National Chung Hsing University, Department of Mechanical Engineering, Taichung (China)

    2012-10-15

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter (D/d = 2), spaced by a gap ratio 0.75 (G/D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 {<=} f{sub e} /f{sub os} {<=} 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f{sub e} /f{sub os} = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f{sub e} /3 (or f{sub os}), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 {<=} f{sub e} /f{sub os} {<=} 3.22 is also not locked-on because the phase difference in the narrow wake excited at f{sub e} /f{sub os} = 2.93 and 3.07 changes significantly. Note f{sub e} and f{sub os} denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively. (orig.)

  8. Bed diameter effects and incipient slugging in gas fluidized beds

    International Nuclear Information System (INIS)

    Agarwal, P.K.

    1986-01-01

    The coalescence and growth of bubble swarms formed at the distributor of a fluidized bed gives rise to lateral as well as vertical distributions of bubble properties. However, existing models employ average bubble properties obtained largely from semi-empirical considerations. In a recent Paper, the author developed a bubble growth model based on a population balance approach. Analytical expressions were derived for the bubble characteristic distributions and averages. However, the model, developed for unconstrained growth, did not take into account the effect of the bed diameter and the possibility of slugging. In this Paper, the model is extended to take these aspects into account. A slugging criterion is also developed which is expected to be valid for the regime where incipient slugging depends on the bed height as well as the region where bed height does not significantly affect minimum slugging conditions

  9. Development of high sensitivity and high speed large size blank inspection system LBIS

    Science.gov (United States)

    Ohara, Shinobu; Yoshida, Akinori; Hirai, Mitsuo; Kato, Takenori; Moriizumi, Koichi; Kusunose, Haruhiko

    2017-07-01

    The production of high-resolution flat panel displays (FPDs) for mobile phones today requires the use of high-quality large-size photomasks (LSPMs). Organic light emitting diode (OLED) displays use several transistors on each pixel for precise current control and, as such, the mask patterns for OLED displays are denser and finer than the patterns for the previous generation displays throughout the entire mask surface. It is therefore strongly demanded that mask patterns be produced with high fidelity and free of defect. To enable the production of a high quality LSPM in a short lead time, the manufacturers need a high-sensitivity high-speed mask blank inspection system that meets the requirement of advanced LSPMs. Lasertec has developed a large-size blank inspection system called LBIS, which achieves high sensitivity based on a laser-scattering technique. LBIS employs a high power laser as its inspection light source. LBIS's delivery optics, including a scanner and F-Theta scan lens, focus the light from the source linearly on the surface of the blank. Its specially-designed optics collect the light scattered by particles and defects generated during the manufacturing process, such as scratches, on the surface and guide it to photo multiplier tubes (PMTs) with high efficiency. Multiple PMTs are used on LBIS for the stable detection of scattered light, which may be distributed at various angles due to irregular shapes of defects. LBIS captures 0.3mμ PSL at a detection rate of over 99.5% with uniform sensitivity. Its inspection time is 20 minutes for a G8 blank and 35 minutes for G10. The differential interference contrast (DIC) microscope on the inspection head of LBIS captures high-contrast review images after inspection. The images are classified automatically.

  10. Liquid crystallinity driven highly aligned large graphene oxide composites

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Eun; Oh, Jung Jae; Yun, Taeyeong [Center for Nanomaterials and Chemical Reactions, Institute for Basic Science (IBS), Daejeon 305-701 (Korea, Republic of); Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of); Kim, Sang Ouk, E-mail: sangouk.kim@kaist.ac.kr [Center for Nanomaterials and Chemical Reactions, Institute for Basic Science (IBS), Daejeon 305-701 (Korea, Republic of); Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of)

    2015-04-15

    Graphene is an emerging graphitic carbon materials, consisting of sp{sup 2} hybridized two dimensinal honeycomb structure. It has been widely studied to incorporate graphene with polymer to utilize unique property of graphene and reinforce electrical, mechanical and thermal property of polymer. In composite materials, orientation control of graphene significantly influences the property of composite. Until now, a few method has been developed for orientation control of graphene within polymer matrix. Here, we demonstrate facile fabrication of high aligned large graphene oxide (LGO) composites in polydimethylsiloxane (PDMS) matrix exploiting liquid crystallinity. Liquid crystalline aqueous dispersion of LGO is parallel oriented within flat confinement geometry. Freeze-drying of the aligned LGO dispersion and subsequent infiltration with PDMS produce highly aligned LGO/PDMS composites. Owing to the large shape anisotropy of LGO, liquid crystalline alignment occurred at low concentration of 2 mg/ml in aqueous dispersion, which leads to the 0.2 wt% LGO loaded composites. - Graphical abstract: Liquid crystalline LGO aqueous dispersions are spontaneous parallel aligned between geometric confinement for highly aligned LGO/polymer composite fabrication. - Highlights: • A simple fabrication method for highly aligned LGO/PDMS composites is proposed. • LGO aqueous dispersion shows nematic liquid crystalline phase at 0.8 mg/ml. • In nematic phase, LGO flakes are highly aligned by geometric confinement. • Infiltration of PDMS into freeze-dried LGO allows highly aligned LGO/PDMS composites.

  11. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  12. Decontamination Strategy for Large Area and/or Equipment Contaminated with Chemical and Biological Agents using a High Energy Arc Lamp (HEAL)

    Energy Technology Data Exchange (ETDEWEB)

    Schoske, Richard [ORNL; Kennedy, Patrick [ORNL; Duty, Chad E [ORNL; Smith, Rob R [ORNL; Huxford, Theodore J [ORNL; Bonavita, Angelo M [ORNL; Engleman, Greg [ORNL; Vass, Arpad Alexander [ORNL; Griest, Wayne H [ORNL; Ilgner, Ralph H [ORNL; Brown, Gilbert M [ORNL

    2009-04-01

    A strategy for the decontamination of large areas and or equipment contaminated with Biological Warfare Agents (BWAs) and Chemical Warfare Agents (CWAs) was demonstrated using a High Energy Arc Lamp (HEAL) photolysis system. This strategy offers an alternative that is potentially quicker, less hazardous, generates far less waste, and is easier to deploy than those currently fielded by the Department of Defense (DoD). For example, for large frame aircraft the United States Air Force still relies on the combination of weathering (stand alone in environment), air washing (fly aircraft) and finally washing the aircraft with Hot Soapy Water (HSW) in an attempt to remove any remaining contamination. This method is laborious, time consuming (upwards of 12+ hours not including decontamination site preparation), and requires large amounts of water (e.g., 1,600+ gallons for a single large frame aircraft), and generates large amounts of hazardous waste requiring disposal. The efficacy of the HEAL system was demonstrated using diisopropyl methyl phosphonate (DIMP) a G series CWA simulant, and Bacillus globigii (BG) a simulant of Bacillus anthracis. Experiments were designed to simulate the energy flux of a field deployable lamp system that could stand-off 17 meters from a 12m2 target area and uniformly expose a surface at 1360 W/m2. The HEAL system in the absence of a catalyst reduced the amount of B. globigii by five orders of magnitude at a starting concentration of 1.63 x 107 spores. In the case of CWA simulants, the HEAL system in the presence of the catalyst TiO2 effectively degraded DIMP sprayed onto a 100mm diameter Petri dish in 5 minutes.

  13. Fitting diameter distribution models to data from forest inventories with concentric plot design

    Energy Technology Data Exchange (ETDEWEB)

    Nanos, N.; Sjöstedt de Luna, S.

    2017-11-01

    Aim: Several national forest inventories use a complex plot design based on multiple concentric subplots where smaller diameter trees are inventoried when lying in the smaller-radius subplots and ignored otherwise. Data from these plots are truncated with threshold (truncation) diameters varying according to the distance from the plot centre. In this paper we designed a maximum likelihood method to fit the Weibull diameter distribution to data from concentric plots. Material and methods: Our method (M1) was based on multiple truncated probability density functions to build the likelihood. In addition, we used an alternative method (M2) presented recently. We used methods M1 and M2 as well as two other reference methods to estimate the Weibull parameters in 40000 simulated plots. The spatial tree pattern of the simulated plots was generated using four models of spatial point patterns. Two error indices were used to assess the relative performance of M1 and M2 in estimating relevant stand-level variables. In addition, we estimated the Quadratic Mean plot Diameter (QMD) using Expansion Factors (EFs). Main results: Methods M1 and M2 produced comparable estimation errors in random and cluster tree spatial patterns. Method M2 produced biased parameter estimates in plots with inhomogeneous Poisson patterns. Estimation of QMD using EFs produced biased results in plots within inhomogeneous intensity Poisson patterns. Research highlights:We designed a new method to fit the Weibull distribution to forest inventory data from concentric plots that achieves high accuracy and precision in parameter estimates regardless of the within-plot spatial tree pattern.

  14. Self-regulating and diameter-selective growth of GaN nanowires

    International Nuclear Information System (INIS)

    Kuo, C-K; Hsu, C-W; Wu, C-T; Lan, Z-H; Mou, C-Y; Chen, C-C; Yang, Y-J; Chen, L-C; Chen, K-H

    2006-01-01

    We report diameter-selective growth of GaN nanowires (NWs) by using mono-dispersed Au nanoparticles (NPs) on a ligand-modified Si substrate. The thiol-terminal silane was found to be effective in producing well-dispersed Au NPs in low density on Si substrates so that the agglomeration of Au NPs during growth could be avoided. The resultant GaN NWs exhibited a narrow diameter distribution and their mean diameter was always larger than, while keeping a deterministic relation with, the size of the Au NPs from which they were grown. A self-regulating steady growth model is proposed to account for the size-control process

  15. Large-area high-efficiency flexible PHOLED lighting panels

    Science.gov (United States)

    Pang, Huiqing; Mandlik, Prashant; Levermore, Peter A.; Silvernail, Jeff; Ma, Ruiqing; Brown, Julie J.

    2012-09-01

    Organic Light Emitting Diodes (OLEDs) provide various attractive features for next generation illumination systems, including high efficiency, low power, thin and flexible form factor. In this work, we incorporated phosphorescent emitters and demonstrated highly efficient white phosphorescent OLED (PHOLED) devices on flexible plastic substrates. The 0.94 cm2 small-area device has total thickness of approximately 0.25 mm and achieved 63 lm/W at 1,000 cd/m2 with CRI = 85 and CCT = 2920 K. We further designed and fabricated a 15 cm x 15 cm large-area flexible white OLED lighting panels, finished with a hybrid single-layer ultra-low permeability single layer barrier (SLB) encapsulation film. The flexible panel has an active area of 116.4 cm2, and achieved a power efficacy of 47 lm/W at 1,000 cd/m2 with CRI = 83 and CCT = 3470 K. The efficacy of the panel at 3,000 cd/m2 is 43 lm/W. The large-area flexible PHOLED lighting panel is to bring out enormous possibilities to the future general lighting applications.

  16. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  17. Large aperture deformable mirror with a transferred single-crystal silicon membrane actuated using large-stroke PZT Unimorph Actuators

    Science.gov (United States)

    Hishinumat, Yoshikazu; Yang, Eui - Hyeok (EH)

    2005-01-01

    We have demonstrated a large aperture (50 mm x 50 mm) continuous membrane deformable mirror (DM) with a large-stroke piezoelectric unimorph actuator array. The DM consists of a continuous, large aperture, silicon membrane 'transferred' in its entirety onto a 20 x 20 piezoelectric unimorph actuator array. A PZT unimorph actuator, 2.5 mm in diameter with optimized PZT/Si thickness and design showed a deflection of 5.7 [m at 20V. An assembled DM showed an operating frequency bandwidth of 30 kHz and influence function of approximately 30%.

  18. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  19. Modeling of large aperture third harmonic frequency conversion of high power Nd:glass laser systems

    International Nuclear Information System (INIS)

    Henesian, M.A.; Wegner, P.J.; Speck, D.R.; Bibeau, C.; Ehrlich, R.B.; Laumann, C.W.; Lawson, J.K.; Weiland, T.L.

    1991-01-01

    To provide high-energy, high-power beams at short wavelengths for inertial-confinement-fusion experiments, we routinely convert the 1.053-μm output of the Nova, Nd:phosphate-glass, laser system to its third-harmonic wavelength. We describe performance and conversion efficiency modeling of the 3 x 3 arrays potassium-dihydrogen-phosphate crystal plates used for type II/type II phase-matched harmonic conversion of Nova 0.74-m diameter beams, and an alternate type I/type II phase-matching configuration that improves the third-harmonic conversion efficiency. These arrays provide energy conversion of up to 65% and intensity conversion to 70%. 19 refs., 11 figs

  20. Reduced power processor requirements for the 30-cm diameter HG ion thruster

    Science.gov (United States)

    Rawlin, V. K.

    1979-01-01

    The characteristics of power processors strongly impact the overall performance and cost of electric propulsion systems. A program was initiated to evaluate simplifications of the thruster-power processor interface requirements. The power processor requirements are mission dependent with major differences arising for those missions which require a nearly constant thruster operating point (typical of geocentric and some inbound planetary missions) and those requiring operation over a large range of input power (such as outbound planetary missions). This paper describes the results of tests which have indicated that as many as seven of the twelve power supplies may be eliminated from the present Functional Model Power Processor used with 30-cm diameter Hg ion thrusters.

  1. Highly Scalable Trip Grouping for Large Scale Collective Transportation Systems

    DEFF Research Database (Denmark)

    Gidofalvi, Gyozo; Pedersen, Torben Bach; Risch, Tore

    2008-01-01

    Transportation-related problems, like road congestion, parking, and pollution, are increasing in most cities. In order to reduce traffic, recent work has proposed methods for vehicle sharing, for example for sharing cabs by grouping "closeby" cab requests and thus minimizing transportation cost...... and utilizing cab space. However, the methods published so far do not scale to large data volumes, which is necessary to facilitate large-scale collective transportation systems, e.g., ride-sharing systems for large cities. This paper presents highly scalable trip grouping algorithms, which generalize previous...

  2. Manufacturing of large and integral-type steel forgings for nuclear steam supply system components

    International Nuclear Information System (INIS)

    Kawaguchi, S.; Tsukada, H.; Suzuki, K.; Sato, I.; Onodera, S.

    1986-01-01

    Forgings for the reactor pressure vessel (RPV) of the pressurized heavy water reactor (PHWR) 700 MWe, which is composed of seven major parts and nozzles totaling about 965 tons, were successfully developed. These forgings are: 1. Flanges: an outside diameter of 8440 mm and a weight of 238 tons max, requiring an ingot of 570 tons. 2. Shells and torus: an outside diameter of about 8000 mm with large height. 3. Cover dome: a diameter of 6800 mm and a thickness of 460 mm, requiring a blank forging before forming of 8000 mm in diameter and 550 m thick. The material designation is 20Mn-Mo-Ni 5 5 (equivalent to SA508, Class 3). In this paper, the manufacturing of and the properties of such large and integral forgings are discussed, including an overview of manufacturing processes for ultralarge-sized forgings over the last two decades

  3. Investigation of the ramp testing behaviour of fuel pins with different diameters

    International Nuclear Information System (INIS)

    Pott, G.; Herren, M.; Wigger, B.

    1979-09-01

    The aim of these experiments was the investigation of the influence of different fuel pin diameter on the ramp testing behaviour. Fuel elements with diameter between 10,75 and 15,6 mm and different cladding thickness had been ramptested in the HBWR (Halden Boiling Water Reactor) after preirradiated in the same facility. Fuel pins with the smallest diameter of 10,75 mm failed. This was indicated by fission gas release measurement. Metallographic examination showed these failure were caused by hydride blisters. A systematic influence of fuel pin diameter and cladding thickness on the ramptesting behaviour was not observed. (orig.) [de

  4. Rapid monitoring of soil, smears, and air dusts by direct large-area alpha spectrometry

    International Nuclear Information System (INIS)

    Sill, C.W.

    1992-01-01

    Experimental conditions to permit rapid monitoring of soils, smears, and air dusts for transuranic (TRU) radionuclides under field conditions are described. The monitoring technique involves direct measurement of alpha emitters by alpha spectrometry using a large-area detector to identify and quantify the radionuclides present. The direct alpha spectrometry employs a circular gridded ionization chamber 35 cm in diameter which accommodates either a circular sample holder 25 cm in diameter or a rectangular one 20 by 25 cm (8 by 10 in.). Soils or settled dusts are finely ground, suspended in 30% ethanol, and sprayed onto a 25-cm stainless steel dish. Air dusts are collected with a high-volume sampler onto 20- by 25-cm membrane filters. Removable contamination is collected from surfaces onto a 20- by 25-cm filter using an 18-cm (7-in.) paint roller to hold the large filter in contact with the surface during sample collection. All three types of samples are then counted directly in the alpha spectrometer and no other sample preparation is necessary. Some results obtained are described

  5. Experience with high heat flux components in large tokamaks

    International Nuclear Information System (INIS)

    Chappuis, P.; Dietz, K.J.; Ulrickson, M.

    1991-01-01

    The large present day tokamaks. i.e.JET, TFTR, JT-60, DIII-D and Tore Supra are machines capable of sustaining plasma currents of several million amperes. Pulse durations range from a few seconds up to a minute. These large machines have been in operation for several years and there exists wide experience with materials for plasma facing components. Bare and coated metals, bare and coated graphites and beryllium were used for walls, limiters and divertors. High heat flux components are mainly radiation cooled, but stationary cooling for long pulse duration is also employed. This paper summarizes the experience gained in the large machines with respect to material selection, component design, problem areas, and plasma performance. 2 tabs., 26 figs., 50 refs

  6. Ecological Importance of Small-Diameter Trees to the Structure, Diversity and Biomass of a Tropical Evergreen Forest at Rabi, Gabon.

    Science.gov (United States)

    Memiaghe, Hervé R; Lutz, James A; Korte, Lisa; Alonso, Alfonso; Kenfack, David

    2016-01-01

    Tropical forests have long been recognized for their biodiversity and ecosystem services. Despite their importance, tropical forests, and particularly those of central Africa, remain understudied. Until recently, most forest inventories in Central Africa have focused on trees ≥10 cm in diameter, even though several studies have shown that small-diameter tree population may be important to demographic rates and nutrient cycling. To determine the ecological importance of small-diameter trees in central African forests, we used data from a 25-ha permanent plot that we established in the rainforest of Gabon to study the diversity and dynamics of these forests. Within the plot, we censused 175,830 trees ≥1 cm dbh from 54 families, 192 genera, and 345 species. Average tree density was 7,026 trees/ha, basal area 31.64 m2/ha, and above-ground biomass 369.40 Mg/ha. Fabaceae, Ebenaceae and Euphorbiaceae were the most important families by basal area, density and above-ground biomass. Small-diameter trees (1 cm ≥ dbh tree population, 16.5% of basal area, and 4.8% of the above-ground biomass. They also had diversity 18% higher at family level, 34% higher at genus level, and 42% higher at species level than trees ≥10 cm dbh. Although the relative contribution of small-diameter trees to biomass was comparable to other forests globally, their contribution to forest density, and diversity was disproportionately higher. The high levels of diversity within small-diameter classes may give these forests high levels of structural resilience to anthropogenic/natural disturbance and a changing climate.

  7. The evaluation of the right inferior phrenic artery diameter in cirrhotic patients.

    Science.gov (United States)

    Esen, Kaan; Balci, Yuksel; Tok, Sermin; Ucbilek, Enver; Kara, Engin; Kaya, Omer

    2017-09-01

    The purpose of this study is to evaluate the relationship between right inferior phrenic artery diameter and portal hypertension in cirrhotic patients. CT examinations of 38 patients with chronic liver disease (patient group) and 40 patients without any liver disease (control group) were evaluated. The right inferior phrenic artery diameter of the patient and control group were measured. CT findings of portal hypertension, which were accepted as ascites, collaterals, splenomegaly and portal vein diameter greater than 13 mm, were determined and scored in the patient group. Patients obtained scores between one and four with respect to portal hypertension findings, and the scores were compared with phrenic artery diameters. Child-Pugh and MELD scores of the patients were also calculated. The mean diameter of the right inferior phrenic artery in the patient group was larger than that in the control group (p phrenic artery diameter of the patients with score 1 was significantly different from those with score 2 (p = 0.028), score 3 (p = 0.001) and score 4 (p = 0.005). We found a linear and moderate relationship between phrenic artery diameter values and Child-Pugh scores (p = 0.012, r = 0.405). Dilatation of the right inferior phrenic artery in cirrhotic patients may be a nonspecific sign of developing portal hypertension.

  8. Evaluating physical property changes for small-diameter, plantation-grown southern pine after in situ polymerization of an acrylic monomer

    Science.gov (United States)

    Richard Bergman; Rebecca E. Ibach; Constantine LaPasha; Joseph Denig

    2009-01-01

    Because of the large percentage of juvenile wood in small-diameter southern pine, this material has lower strength properties compared with the historic published values in the ASTM Standard D2555. Finding new, simple, and inexpensive ways of increasing these strength properties would increase the use of this material for residential construction. For this study, we...

  9. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. A Large High Vacuum Reaction Chamber for Nuclear Physics Research at VECC, Kolkata

    International Nuclear Information System (INIS)

    Kundu, S; Bhattacharya, S; Meena, J K; Ghosh, T K; Bhattacharjee, T; Mukhopadhyay, P; Bhattacharya, C; Rana, T K; Banerjee, K; Mukherjee, G; Banerjee, S R; Bandyopadhyay, D L; Ahammed, M; Bhattacharya, P

    2012-01-01

    A large, segmented, horizontal axis, reaction chamber (SHARC) has recently been fabricated, installed and integrated with the beam line in the VECC superconducting cyclotron (SCC) experimental area. It is a cylindrical, three segment, stainless steel chamber of length 2.2 m, diameter 1 m. Two pairs of parallel rails have been provided internally for placement of the target assembly and detector systems within the chamber. The whole target assembly can be placed anywhere on the rail to facilitate optimum flight path. The nominal vacuum of ∼1×10 −7 mbar has been obtained in ∼8 hrs by means of two turbo molecular (1000 l/s) and two cryo pumps (2500 l/s) backed by mechanical pumps. The whole vacuum system as well as the target positioning (vertical and rotational movements) operations are fully automated with manual override option; both are monitored and controlled locally as well as remotely through the local and remote control units providing real time status display.

  11. Laser-induced production of large carbon-based toroids

    International Nuclear Information System (INIS)

    Lyn, M. Elizabeth; He Jibao; Koplitz, Brent

    2005-01-01

    We report on the production of large carbon-based toroids (CBTs) from fullerenes. The process involves two-step laser irradiation of a mixed fullerene target (76% C 60 , 22% C 70 ). Transmission electron microscopy (TEM) clearly identifies toroidal-shaped structures as well as Q-shaped constructs. The typical diameters of the CBTs are ∼0.2-0.3 μm with tubular diameters of ∼50-100 nm, but toroids as wide as 0.5 μm are observed making them nanostructures on the verge of being microstructures

  12. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  13. A diameter increment model for Red Fir in California and Southern Oregon

    Science.gov (United States)

    K. Leroy Dolph

    1992-01-01

    Periodic (10-year) diameter increment of individual red fir trees in Califomia and southern Oregon can be predicted from initial diameter and crown ratio of each tree, site index, percent slope, and aspect of the site. The model actually predicts the natural logarithm ofthe change in squared diameter inside bark between the startand the end of a 10-year growth period....

  14. Elevated temperature and high pressure large helium gas loop

    International Nuclear Information System (INIS)

    Sakasai, Minoru; Midoriyama, Shigeru; Miyata, Toyohiko; Nakase, Tsuyoshi; Izaki, Makoto

    1979-01-01

    The development of high temperature gas-cooled reactors especially aiming at the multi-purpose utilization of nuclear heat energy is carried out actively in Japan and West Germany. In Japan, the experimental HTGR of 50 MWt and 1000 deg C outlet temperature is being developed by Japan Atomic Energy Research Institute and others since 1969, and the development of direct iron-making technology utilizing high temperature reducing gas was started in 1973 as the large project of Ministry of Internalional Trade and Industry. Kawasaki Heavy Industries, Ltd., Has taken part in these development projects, and has developed many softwares for nuclear heat design, system design and safety design of nuclear reactor system and heat utilization system. In hardwares also, efforts have been exerted to develop the technologies of design and manufacture of high temperature machinery and equipments. The high temperature, high pressure, large helium gas loop is under construction in the technical research institute of the company, and it is expected to be completed in December, 1979. The tests planned are that of proving the dynamic performances of the loop and its machinery and equipments and the verification of analysis codes. The loop is composed of the main circulation system, the objects of testing, the helium gas purifying system, the helium supplying and evacuating system, instruments and others. (Kako, I.)

  15. Iodine oxides in large-scale THAI tests

    International Nuclear Information System (INIS)

    Funke, F.; Langrock, G.; Kanzleiter, T.; Poss, G.; Fischer, K.; Kühnel, A.; Weber, G.; Allelein, H.-J.

    2012-01-01

    Highlights: ► Iodine oxide particles were produced from gaseous iodine and ozone. ► Ozone replaced the effect of ionizing radiation in the large-scale THAI facility. ► The mean diameter of the iodine oxide particles was about 0.35 μm. ► Particle formation was faster than the chemical reaction between iodine and ozone. ► Deposition of iodine oxide particles was slow in the absence of other aerosols. - Abstract: The conversion of gaseous molecular iodine into iodine oxide aerosols has significant relevance in the understanding of the fission product iodine volatility in a LWR containment during severe accidents. In containment, the high radiation field caused by fission products released from the reactor core induces radiolytic oxidation into iodine oxides. To study the characteristics and the behaviour of iodine oxides in large scale, two THAI tests Iod-13 and Iod-14 were performed, simulating radiolytic oxidation of molecular iodine by reaction of iodine with ozone, with ozone injected from an ozone generator. The observed iodine oxides form submicron particles with mean volume-related diameters of about 0.35 μm and show low deposition rates in the THAI tests performed in the absence of other nuclear aerosols. Formation of iodine aerosols from gaseous precursors iodine and ozone is fast as compared to their chemical interaction. The current approach in empirical iodine containment behaviour models in severe accidents, including the radiolytic production of I 2 -oxidizing agents followed by the I 2 oxidation itself, is confirmed by these THAI tests.

  16. Honeycomblike large area LaB6 plasma source for Multi-Purpose Plasma facility

    International Nuclear Information System (INIS)

    Woo, Hyun-Jong; Chung, Kyu-Sun; You, Hyun-Jong; Lee, Myoung-Jae; Lho, Taihyeop; Choh, Kwon Kook; Yoon, Jung-Sik; Jung, Yong Ho; Lee, Bongju; Yoo, Suk Jae; Kwon, Myeon

    2007-01-01

    A Multi-Purpose Plasma (MP 2 ) facility has been renovated from Hanbit mirror device [Kwon et al., Nucl. Fusion 43, 686 (2003)] by adopting the same philosophy of diversified plasma simulator (DiPS) [Chung et al., Contrib. Plasma Phys. 46, 354 (2006)] by installing two plasma sources: LaB 6 (dc) and helicon (rf) plasma sources; and making three distinct simulators: divertor plasma simulator, space propulsion simulator, and astrophysics simulator. During the first renovation stage, a honeycomblike large area LaB 6 (HLA-LaB 6 ) cathode was developed for the divertor plasma simulator to improve the resistance against the thermal shock fragility for large and high density plasma generation. A HLA-LaB 6 cathode is composed of the one inner cathode with 4 in. diameter and the six outer cathodes with 2 in. diameter along with separate graphite heaters. The first plasma is generated with Ar gas and its properties are measured by the electric probes with various discharge currents and magnetic field configurations. Plasma density at the middle of central cell reaches up to 2.6x10 12 cm -3 , while the electron temperature remains around 3-3.5 eV at the low discharge current of less than 45 A, and the magnetic field intensity of 870 G. Unique features of electric property of heaters, plasma density profiles, is explained comparing with those of single LaB 6 cathode with 4 in. diameter in DiPS

  17. Development of high purity large forgings for nuclear power plants

    International Nuclear Information System (INIS)

    Tanaka, Yasuhiko; Sato, Ikuo

    2011-01-01

    The recent increase in the size of energy plants has been supported by the development of manufacturing technology for high purity large forgings for the key components of the plant. To assure the reliability and performance of the large forgings, refining technology to make high purity steels, casting technology for gigantic ingots, forging technology to homogenize the material and consolidate porosity are essential, together with the required heat treatment and machining technologies. To meet these needs, the double degassing method to reduce impurities, multi-pouring methods to cast the gigantic ingots, vacuum carbon deoxidization, the warm forging process and related technologies have been developed and further improved. Furthermore, melting facilities including vacuum induction melting and electro slag re-melting furnaces have been installed. By using these technologies and equipment, large forgings have been manufactured and shipped to customers. These technologies have also been applied to the manufacture of austenitic steel vessel components of the fast breeder reactors and components for fusion experiments.

  18. Development of high purity large forgings for nuclear power plants

    Science.gov (United States)

    Tanaka, Yasuhiko; Sato, Ikuo

    2011-10-01

    The recent increase in the size of energy plants has been supported by the development of manufacturing technology for high purity large forgings for the key components of the plant. To assure the reliability and performance of the large forgings, refining technology to make high purity steels, casting technology for gigantic ingots, forging technology to homogenize the material and consolidate porosity are essential, together with the required heat treatment and machining technologies. To meet these needs, the double degassing method to reduce impurities, multi-pouring methods to cast the gigantic ingots, vacuum carbon deoxidization, the warm forging process and related technologies have been developed and further improved. Furthermore, melting facilities including vacuum induction melting and electro slag re-melting furnaces have been installed. By using these technologies and equipment, large forgings have been manufactured and shipped to customers. These technologies have also been applied to the manufacture of austenitic steel vessel components of the fast breeder reactors and components for fusion experiments.

  19. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  20. Large Payload Ground Transportation and Test Considerations

    Science.gov (United States)

    Rucker, Michelle A.

    2016-01-01

    Many spacecraft concepts under consideration by the National Aeronautics and Space Administration’s (NASA’s) Evolvable Mars Campaign take advantage of a Space Launch System payload shroud that may be 8 to 10 meters in diameter. Large payloads can theoretically save cost by reducing the number of launches needed--but only if it is possible to build, test, and transport a large payload to the launch site in the first place. Analysis performed previously for the Altair project identified several transportation and test issues with an 8.973 meters diameter payload. Although the entire Constellation Program—including Altair—has since been canceled, these issues serve as important lessons learned for spacecraft designers and program managers considering large payloads for future programs. A transportation feasibility study found that, even broken up into an Ascent and Descent Module, the Altair spacecraft would not fit inside available aircraft. Ground transportation of such large payloads over extended distances is not generally permitted, so overland transportation alone would not be an option. Limited ground transportation to the nearest waterway may be possible, but water transportation could take as long as 67 days per production unit, depending on point of origin and acceptance test facility; transportation from the western United States would require transit through the Panama Canal to access the Kennedy Space Center launch site. Large payloads also pose acceptance test and ground processing challenges. Although propulsion, mechanical vibration, and reverberant acoustic test facilities at NASA’s Plum Brook Station have been designed to accommodate large spacecraft, special handling and test work-arounds may be necessary, which could increase cost, schedule, and technical risk. Once at the launch site, there are no facilities currently capable of accommodating the combination of large payload size and hazardous processing such as hypergolic fuels