WorldWideScience

Sample records for laboratory tests commonly

  1. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    Science.gov (United States)

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  2. Evaluation of Mycology Laboratory Proficiency Testing

    Science.gov (United States)

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  3. Making Sense of Fear Testing - Validating Common Behavioral Tests used in Swine

    Science.gov (United States)

    Tests to assess fear are commonly used in laboratory animals, such as mice and rats, when researchers wish to understand the implications of specific drugs, such as anxiolytics, or specific environments which may be used to house experimental animals. Researchers who study the welfare of livestock ...

  4. Evaluation of common diseases in laboratory animals | Oguwike ...

    African Journals Online (AJOL)

    , diet or faulty functioning of a process. Laboratory animals are prone to some of these diseases. This study was undertaken to evaluate common diseases found in laboratory animals in our environment. 200 animals consisting of rats, mice, ...

  5. Immediate needs for MQA testing at state secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Cline, R. [Radiation Instrument Calibration Laboratory, Springfield, IL (United States)

    1993-12-31

    The Calibration Laboratory attempts to provide services that satisfy the needs and requests for a variety of customers. New needs and requests have resulted in calibration of instrumentation outside the original laboratory designs. These tasks require several changes at the laboratory and a need for new support services, especially measurement quality assurance (MQA). The MQA tests are gamma (Cs-137) below 0.5 mrem (5{mu}Sv) per hour and x-ray kVp. Modification to the current gamma (Cs-137) MQA test is recommended because lower intensity fields are commonly measured.

  6. Immediate needs for MQA testing at state secondary calibration laboratories

    International Nuclear Information System (INIS)

    Cline, R.

    1993-01-01

    The Calibration Laboratory attempts to provide services that satisfy the needs and requests for a variety of customers. New needs and requests have resulted in calibration of instrumentation outside the original laboratory designs. These tasks require several changes at the laboratory and a need for new support services, especially measurement quality assurance (MQA). The MQA tests are gamma (Cs-137) below 0.5 mrem (5μSv) per hour and x-ray kVp. Modification to the current gamma (Cs-137) MQA test is recommended because lower intensity fields are commonly measured

  7. Laboratory Tests

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & ... What are lab tests? Laboratory tests are medical devices that are intended for use on samples of blood, urine, or other tissues ...

  8. Variations in biochemical values for common laboratory tests: a comparison among multi-ethnic Israeli women cohort.

    Science.gov (United States)

    Birk, Ruth; Heifetz, Eliyahu M

    2018-04-28

    Biochemical laboratory values are an essential tool in medical diagnosis, treatment, and follow-up; however, they are known to vary between populations. Establishment of ethnicity-adjusted reference values is recommended by health organizations. To investigate the ethnicity element in biochemical lab values studying women of different ethnic groups. Biochemical lab values (n = 27) of 503 adult Israeli women of three ethnicities (Jewish Ashkenazi, Jewish Sephardic, and Bedouin Arab) attending a single medical center were analyzed. Biochemical data were extracted from medical center records. Ethnic differences of laboratory biochemicals were studied using ANCOVA to analyze the center of the distribution as well as quartile regression analysis to analyze the upper and lower limits, both done with an adjustment for age. Significant ethnic differences were found in almost half (n = 12) of the biochemical laboratory tests. Ashkenazi Jews exhibited significantly higher mean values compared to Bedouins in most of the biochemical tests, including albumin, alkaline phosphatase, calcium, cholesterol, cholesterol LDL and HDL, cholesterol LDL calc., folic acid, globulin, and iron saturation, while the Bedouins exhibited the highest mean values in the creatinine and triglycerides. For most of these tests, Sephardic Jews exhibited biochemical mean levels in between the two other groups. Compared to Ashkenazi Jews, Sephardic Jews had a significant shift to lower values in cholesterol LDL. Ethnic subpopulations have distinct distributions in biochemical laboratory test values, which should be taken into consideration in medical practice enabling precision medicine.

  9. [Laboratory medicine in the obligatory postgraduate clinical training system--common clinical training program in the department of laboratory medicine in our prefectural medical university hospital].

    Science.gov (United States)

    Okamoto, Yasuyuki

    2003-04-01

    I propose a postgraduate common clinical training program to be provided by the department of laboratory medicine in our prefectural medical university hospital. The program has three purposes: first, mastering basic laboratory tests; second, developing the skills necessary to accurately interpret laboratory data; third, learning specific techniques in the field of laboratory medicine. For the first purpose, it is important that medical trainees perform testing of their own patients at bedside or in the central clinical laboratory. When testing at the central clinical laboratory, instruction by expert laboratory technicians is helpful. The teaching doctors in the department of laboratory medicine are asked to advise the trainees on the interpretation of data. Consultation will be received via interview or e-mail. In addition, the trainees can participate in various conferences, seminars, and meetings held at the central clinical laboratory. Finally, in order to learn specific techniques in the field of laboratory medicine, several special courses lasting a few months will be prepared. I think this program should be closely linked to the training program in internal medicine.

  10. [Laboratory accreditation and proficiency testing].

    Science.gov (United States)

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  11. FOOD SAFETY TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory develops screening assays, tests and modifies biosensor equipment, and optimizes food safety testing protocols for the military and civilian sector...

  12. Laboratory testing in hyperthyroidism.

    Science.gov (United States)

    Grebe, Stefan K G; Kahaly, George J

    2012-09-01

    The clinical diagnosis of hypo- or hyperthyroidism is difficult (full text available online: http://education.amjmed.com/pp1/272). Clinical symptoms and signs are often non-specific, and there is incomplete correlation between structural and functional thyroid gland changes. Laboratory testing is therefore indispensible in establishing the diagnosis of thyrotoxicosis. Similar considerations apply to treatment monitoring. Laboratory testing also plays a crucial role in establishing the most likely cause for a patient's hyperthyroidism. Finally, during pregnancy, when isotopic scanning is relatively contraindicated and ultrasound is more difficult to interpret, laboratory testing becomes even more important. Copyright © 2012. Published by Elsevier Inc.

  13. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    Science.gov (United States)

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  14. The Cost-Effective Laboratory: Implementation of Economic Evaluation of Laboratory Testing

    Directory of Open Access Journals (Sweden)

    Bogavac-Stanojevic Natasa

    2017-09-01

    Full Text Available Laboratory testing as a part of laboratory in vitro diagnostic (IVD has become required tool in clinical practice for diagnosing, monitoring and prognosis of diseases, as well as for prediction of treatment response. The number of IVD tests available in laboratory practice has increased over the past decades and is likely to further increase in the future. Consequently, there is growing concern about the overutilization of laboratory tests and rising costs for laboratory testing. It is estimated that IVD accounts for between 1.4 and 2.3% of total healthcare expenditure and less than 5% of total hospital cost (Lewin Group report. These costs are rather low when compared to pharmaceuticals and medical aids which account for 15 and 5%, respectively. On the other hand, IVD tests play an important role in clinical practice, as they influence from 60% to 70% of clinical decision-making. Unfortunately, constant increases in healthcare spending are not directly related to healthcare benefit. Since healthcare resources are limited, health payers are interested whether the benefits of IVD tests are actually worth their cost. Many articles have introduced frameworks to assess the economic value of IVD tests. The most appropriate tool for quantitative assessment of their economic value is cost-effectiveness (CEA and cost-utility (CUA analysis. The both analysis determine cost in terms of effectiveness or utilities (combine quantity and quality of life of new laboratory test against its alternative. On the other hand, some investigators recommended calculation of laboratory test value as product of two ratios: Laboratory test value = (Technical accuracy/Turnaround time × (Utility/Costs. Recently, some researches used multicriteria decision analysis which allows comparison of diagnostic strategies in terms of benefits, opportunities, costs and risks. All analyses are constructed to identify laboratory test that produce the greatest healthcare benefit with

  15. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    Science.gov (United States)

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  16. Biometric identification devices -- Laboratory testing vs. real life

    International Nuclear Information System (INIS)

    Ahrens, J.S.

    1997-01-01

    For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer's performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy's needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people using the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations

  17. Summary report - development of laboratory tests and the stress- strain behaviour of Olkiluoto mica gneiss

    International Nuclear Information System (INIS)

    Hakala, M.; Heikkilae, E.

    1997-05-01

    This work summarizes the project aimed at developing and qualifying a suitable combination of laboratory tests to establish a statistically reliable stress-strain behaviour of the main rock types at Posiva Oy's detailed investigation sites for disposal of spent nuclear fuel. The work includes literature study of stress-strain behaviour of brittle rock, development and qualification of laboratory tests, suggested test procedures and interpretation methods and finally testing of Olkiluoto mica gneiss. The Olkiluoto study includes over 130 loading tests. Besides the commonly used laboratory tests, direct tensile tests, damage controlled tests and acoustic emission measurements were also carried out. (orig.) (54 refs.)

  18. Understanding Laboratory Tests

    Science.gov (United States)

    ... and Drug Administration (FDA) regulates the development and marketing of all laboratory tests that use test kits ... Cancer.gov en español Multimedia Publications Site Map Digital Standards for NCI Websites POLICIES Accessibility Comment Policy ...

  19. Metallurgical Laboratory and Components Testing

    Data.gov (United States)

    Federal Laboratory Consortium — In the field of metallurgy, TTC is equipped to run laboratory tests on track and rolling stock components and materials. The testing lab contains scanning-electron,...

  20. Summary report - development of laboratory tests and the stress- strain behaviour of Olkiluoto mica gneiss

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, M.; Heikkilae, E. [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Rock Engineering

    1997-05-01

    This work summarizes the project aimed at developing and qualifying a suitable combination of laboratory tests to establish a statistically reliable stress-strain behaviour of the main rock types at Posiva Oy`s detailed investigation sites for disposal of spent nuclear fuel. The work includes literature study of stress-strain behaviour of brittle rock, development and qualification of laboratory tests, suggested test procedures and interpretation methods and finally testing of Olkiluoto mica gneiss. The Olkiluoto study includes over 130 loading tests. Besides the commonly used laboratory tests, direct tensile tests, damage controlled tests and acoustic emission measurements were also carried out. (orig.) (54 refs.).

  1. Test Cost and Test Accuracy in Clinical Laboratories in Kampala, Uganda.

    Science.gov (United States)

    Amukele, Timothy K; Jones, Robert; Elbireer, Ali

    2018-04-25

    To assess the accuracy and costs of laboratory tests in Kampala, Uganda. A random selection of 78 laboratories tested external quality assurance samples at market rates. There were 40 moderate- to high-complexity and 38 low-complexity laboratories. Four percent (3/78) of these laboratories were accredited and 94% (73/78) were private. The 40 moderate- to high-complexity laboratories performed malaria blood smear, urine human chorionic gonadotropin (hCG), human immunodeficiency virus (HIV), syphilis, glucose, and three-panel tests: CBC, liver function tests, and kidney function tests. The 38 low-complexity laboratories performed malaria blood smear, urine hCG, and syphilis testing only. Hematology, HIV, syphilis, and malarial proficiency testing samples were prepared by accredited laboratories in Kampala. All other samples were provided by the Royal College of Pathologists of Australia. 77.1% of all results were accurate (met target values). It varied widely by laboratory (50%-100%), test identity (malaria blood smear, 96%; serum urea nitrogen, 38%), and test type (quantitative: 66% [31%-89%], qualitative: 91% [68%-97%]). Test prices varied by up to 3,600%, and there was no correlation between test cost and accuracy (r2 = 0.02). There were large differences in accuracy and price across laboratories in Kampala. Price was not associated with quality.

  2. Laboratories of commons: experimentation, recursivity and activism

    Directory of Open Access Journals (Sweden)

    Adolfo Estalella Fernández

    2013-03-01

    Full Text Available The urban public space, digital creations or the air, all of them are objects that have been traditionally thought within the dichotomous logic of the public and private property but in the last decade they have started to be considered as common resources. Commons is an old concept that has been recovered with intensity in the last decade; it refers to collective resources and goods that are governed collectively and whose property regime is different from the public and private. This article introduces the contributions to a monograph devoted to the topic of ‘Laboratories of commons’. Contributors discuss the diverse modalities of commons in different social domains like art, activism, the rural and the urban domain. This introduction contextualizes these contributions and identifies some of the issues that cross the different articles. In this exercise we introduce a tentative argument according to which the commons and the commons research take an exceptional configuration in Spain. Very briefly: commons are brought into existence as an epistemic object, an experimental domain quite different from the conventional conceptualizations that conceive it as a property regime or a type of good. This peculiar configuration gives a distinctive condition to commons in Spain that are different from other geographies; this is evidenced in a double shift: the emergence of new objects that are thought as commons and the location of their research in the domain of cultural and creative production.

  3. Use of the National Committee for Clinical Laboratory Standards Guidelines for Disk Diffusion Susceptibility Testing in New York State Laboratories

    Science.gov (United States)

    Kiehlbauch, Julia A.; Hannett, George E.; Salfinger, Max; Archinal, Wendy; Monserrat, Catherine; Carlyn, Cynthia

    2000-01-01

    Accurate antimicrobial susceptibility testing is vital for patient care and surveillance of emerging antimicrobial resistance. The National Committee for Clinical Laboratory Standards (NCCLS) outlines generally agreed upon guidelines for reliable and reproducible results. In January 1997 we surveyed 320 laboratories participating in the New York State Clinical Evaluation Program for General Bacteriology proficiency testing. Our survey addressed compliance with NCCLS susceptibility testing guidelines for bacterial species designated a problem (Staphylococcus aureus and Enterococcus species) or fastidious (Streptococcus pneumoniae, Haemophilus influenzae, and Neisseria gonorrhoeae) organism. Specifically, we assessed compliance with guidelines for inoculum preparation, medium choice, number of disks per plate, and incubation conditions for disk diffusion tests. We also included length of incubation for S. aureus and Enterococcus species. We found overall compliance with the five characteristics listed above in 80 of 153 responding laboratories (50.6%) for S. aureus and 72 of 151 (47.7%) laboratories for Enterococcus species. The most common problem was an incubation time shortened to less than 24 h. Overall compliance with the first four characteristics was reported by 92 of 221 (41.6%) laboratories for S. pneumoniae, 49 of 163 (30.1%) laboratories for H. influenzae, and 11 of 77 (14.3%) laboratories for N. gonorrhoeae. Laboratories varied from NCCLS guidelines by placing an excess number of disks per plate. Laboratories also reported using alternative media for Enterococcus species, N. gonorrhoeae, and H. influenzae. This study demonstrates a need for education among clinical laboratories to increase compliance with NCCLS guidelines. PMID:10970381

  4. Anthropomorphic Test Drive (ATD) Certification Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ATD Certification Laboratory consists of several test fixtures to ensure ATDs are functioning correctly and within specifications prior to use in any OP testing....

  5. Reproducibility of pop-ins in laboratory testing of welded joints

    Directory of Open Access Journals (Sweden)

    Berejnoi C.

    2000-01-01

    Full Text Available The pop-in phenomenon, quite common in fracture mechanics tests of welded joints, corresponds to a brittle crack initiation grown from a local brittle zone (LBZ that is arrested in reaching the higher toughness material that surrounds this LBZ. A methodology to obtain a high percentage of pop-in occurrence in laboratory testing is necessary to study the pop-in significance. Such a method is introduced in this work and includes the consumable combination and welding procedures for the SMAW welding process to generate artificial LBZ. In order to find out the influence of the loading state upon the pop-in phenomenon, laboratory CTOD tests were performed using two specimen configurations: some single edge-notched specimens were loaded on a three-point bending (SE(B fixture while others were tested in tensile load (SE(T. A higher frequency of pop-in occurrence was observed in the SE(B geometry.

  6. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    Science.gov (United States)

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  7. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    Science.gov (United States)

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  8. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  9. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  10. A survey of methods used for antimicrobial susceptibility testing in veterinary diagnostic laboratories in the United States.

    Science.gov (United States)

    Dargatz, David A; Erdman, Matthew M; Harris, Beth

    2017-09-01

    Antimicrobial resistance is a serious threat to animal and human health worldwide, requiring a collaborative, holistic approach. The U.S. Government has developed a national strategy to address antimicrobial resistance, with one component being to monitor antimicrobial resistance in agricultural settings. We developed a survey to collect information about antimicrobial susceptibility testing (AST) from the veterinary diagnostic laboratory community in the United States, assessing current practices and technologies and determining how AST information is shared. Of the 132 surveys administered, 52 (39%) were returned. Overall, responding laboratories conducted susceptibility tests on 98,788 bacterial isolates in 2014, with Escherichia coli being the most common pathogen tested across all animal species. The 2 most common AST methods employed were the disk diffusion method (71%) and the Sensititre platform broth microdilution system (59%). Laboratories primarily used the Clinical Laboratory Standards Institute (CLSI) VET-01 standard (69%) and the automatically calculated interpretations provided by the commercial AST systems (61%) for interpreting their AST data. Only 22% of laboratories published AST data on a periodic basis, usually via annual reports published on the laboratory's website or through peer-reviewed journals for specific pathogens. Our results confirm that disk diffusion and broth microdilution remain the standard AST methods employed by U.S. veterinary diagnostic laboratories, and that CLSI standards are commonly used for interpreting AST results. This information will help determine the most efficient standardized methodology for future surveillance. Furthermore, the current infrastructure within laboratories, once harmonized, will help provide a mechanism for conducting national surveillance programs.

  11. Relay testing at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.

    1989-01-01

    Brookhaven National Laboratory (BNL) is conducting a seismic test program on relays. The purpose of the test program is to investigate the influence of various designs, electrical and vibration parameters on the seismic capacity levels. The first series of testing has been completed and performed at Wyle Laboratories. The major part of the test program consisted of single axis, single frequency sine dwell tests. Random multiaxis, multifrequency tests were also performed. Highlights of the test results as well as a description of the testing methods are presented in this paper. 10 figs

  12. Nuclear magnetic resonance common laboratory, quadrennial report

    International Nuclear Information System (INIS)

    1994-01-01

    This quadrennial report of the nuclear magnetic resonance common laboratory gives an overview of the main activities. Among the different described activities, only one is interesting for the INIS database: it concerns the Solid NMR of cements used for radioactive wastes storage. In this case, the NMR is used to characterize the structure of the material and the composition, structure and kinetics of formation of the alteration layer which is formed at the surface of concrete during water leaching conditions. The NMR methodology is given. (O.M.)

  13. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    Science.gov (United States)

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  14. Laboratory for filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1987-07-01

    Filters used for mine draining in brown coal surface mines are tested by the Mine Draining Department of Poltegor. Laboratory tests of new types of filters developed by Poltegor are analyzed. Two types of tests are used: tests of scale filter models and tests of experimental units of new filters. Design and operation of the test stands used for testing mechanical properties and hydraulic properties of filters for coal mines are described: dimensions, pressure fluctuations, hydraulic equipment. Examples of testing large-diameter filters for brown coal mines are discussed.

  15. The financial imperative of physicians to control demand of laboratory testing.

    LENUS (Irish Health Repository)

    Murphy, R K J

    2012-02-01

    It is an integral component of doctor\\'s duty of care to understand the significant impact laboratory testing has on the expense an ultimate quality of healthcare patients receive, yet the costs of these tests are poorly perceived. Utilising semi-structured interviews and questionnaires, we assessed surgeon\\'s perceived costs of two commonly encountered clinical scenarios requiring out of hours laboratory testing. Of the 35 participants only 23.3% (n = 7) accurately estimated the overall cost. The most expensive test was "Type and Screen" at Euro 83, with 77.3% (n = 17) underestimating the cost. Non-consultant hospital doctors qualified for 3 years were more likely to underestimate on-call costs (p = 0.042). It is of utmost importance to improve the knowledge of all surgeons of the financial implications of investigations. Through education we can potentially reduce un-warranted costs and fulfill our duty of care in the most cost efficient manner.

  16. Common ground: An environmental ethic for Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, F.L.

    1991-01-01

    Three predominant philosophies have characterized American business ethical thinking over the past several decades. The first phase is the ethics of self-interest'' which argues that maximizing self-interest coincidentally maximizes the common good. The second phase is legality ethics.'' Proponents argue that what is important is knowing the rules and following them scrupulously. The third phase might be called stake-holder ethics.'' A central tenant is that everyone affected by a decision has a moral hold on the decision maker. This paper will discuss one recent initiative of the Los Alamos National Laboratory to move beyond rules and regulations toward an environmental ethic that integrates the values of stakeholder ethics'' into the Laboratory's historical culture and value systems. These Common Ground Principles are described. 11 refs.

  17. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  18. Identification of an astrovirus commonly infecting laboratory mice in the US and Japan.

    Directory of Open Access Journals (Sweden)

    Terry Fei Fan Ng

    Full Text Available Mice (Mus musculus are the most commonly used laboratory animals. Viral metagenomics on tissues of immunodeficient mice revealed sequences of a novel mammalian astrovirus. Using PCR, we screened mice from 4 breeders, 4 pharmaceutical companies, 14 research institutes and 30 universities in the US and Japan. Mice from one US breeder tested positive while none from Japanese breeders were positive for MuAstV. Mice in over half of the universities (19/30, institutes (7/14 and pharmaceutical animal facilities (2/4 investigated revealed the presence of MuAstV. Nine mice strains tested positive including both immunodeficient strains (NSG, NOD-SCID, NSG-3GS, C57BL6-Timp-3 (-/-, and uPA-NOG and immunocompetent strains (B6J, ICR, Bash2, BALB/c. Our data indicates that MuAstV has a wide geographical, institutional and host strain distribution. Comparison of the MuAstV RdRp sequences showed numerous mutations indicating ongoing viral divergence in different facilities. This study demonstrates the need for metagenomic screening of laboratory animals to identify adventitious infections that may affect experimental outcomes.

  19. [Quality use of commercial laboratory for clinical testing services - considering laboratory's role].

    Science.gov (United States)

    Ogawa, Shinji

    2014-12-01

    The number of commercial laboratories for clinical testing in Japan run privately has decreased to about 30 companies, and their business is getting tougher. Branch Lab. and FMS businesses have not expanded recently due to the new reimbursement system which adds an additional sample management fee, becoming effective in 2010. This presentation gives an outline of each role for hospital and commercial laboratories, and their pros & cons considering the current medical situation. Commercial laboratories have investigated how to utilize ICT systems for sharing test information between hospitals and our facilities. It would be very helpful to clarify issues for each hospital. We will develop and create new values for clinical laboratory testing services and forge mutually beneficial relationships with medical institutions. (Review).

  20. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    Science.gov (United States)

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  1. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel cell research and development projects through in-situ fuel cell testing. Photo of a researcher running

  2. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  3. Evaluation of Mycology Laboratory Proficiency Testing

    OpenAIRE

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient te...

  4. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  5. Laboratory test result interpretation for primary care doctors in South Africa

    Directory of Open Access Journals (Sweden)

    Naadira Vanker

    2017-03-01

    Full Text Available Background: Challenges and uncertainties with test result interpretation can lead to diagnostic errors. Primary care doctors are at a higher risk than specialists of making these errors, due to the range in complexity and severity of conditions that they encounter. Objectives: This study aimed to investigate the challenges that primary care doctors face with test result interpretation, and to identify potential countermeasures to address these. Methods: A survey was sent out to 7800 primary care doctors in South Africa. Questionnaire themes included doctors’ uncertainty with interpreting test results, mechanisms used to overcome this uncertainty, challenges with appropriate result interpretation, and perceived solutions for interpreting results. Results: Of the 552 responses received, the prevalence of challenges with result interpretation was estimated in an average of 17% of diagnostic encounters. The most commonly-reported challenges were not receiving test results in a timely manner (51% of respondents and previous results not being easily available (37%. When faced with diagnostic uncertainty, 84% of respondents would either follow-up and reassess the patient or discuss the case with a specialist, and 67% would contact a laboratory professional. The most useful test utilisation enablers were found to be: interpretive comments (78% of respondents, published guidelines (74%, and a dedicated laboratory phone line (72%. Conclusion: Primary care doctors acknowledge uncertainty with test result interpretation. Potential countermeasures include the addition of patient-specific interpretive comments, the availability of guidelines or algorithms, and a dedicated laboratory phone line. The benefit of enhanced test result interpretation would reduce diagnostic error rates.

  6. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  7. In situ vitrification laboratory-scale test work plan

    International Nuclear Information System (INIS)

    Nagata, P.K.; Smith, N.L.

    1991-05-01

    The Buried Waste Program was established in October 1987 to accelerate the studies needed to develop a long-term management plan for the buried mixed waste at the Radioactive Waste Management Complex at Idaho Engineering Laboratory. The In Situ Vitrification Project is being conducted in a Comprehensive Environmental Response, Compensation, and Liability Act feasibility study format to identify methods for the long-term management of mixed buried waste. To support the overall feasibility study, the situ vitrification treatability investigations are proceeding along the three parallel paths: laboratory-scale tests, intermediate field tests, and field tests. Laboratory-scale tests are being performed to provide data to mathematical modeling efforts, which, in turn, will support design of the field tests and to the health and safety risk assessment. This laboratory-scale test work plan provides overall testing program direction to meet the current goals and objectives of the in situ vitrification treatability investigation. 12 refs., 1 fig., 7 tabs

  8. Laboratory-based testing to evaluate abuse-deterrent formulations and satisfy the Food and Drug Administration's recommendation for Category 1 Testing.

    Science.gov (United States)

    Altomare, Christopher; Kinzler, Eric R; Buchhalter, August R; Cone, Edward J; Costantino, Anthony

    The US Food and Drug Administration (FDA) considers the development of abuse-deterrent formulations of solid oral dosage forms a public health priority and has outlined a series of premarket studies that should be performed prior to submitting an application to the Agency. Category 1 studies are performed to characterize whether the abuse-deterrent properties of a new formulation can be easily defeated. Study protocols are designed to evaluate common abuse patterns of prescription medications as well as more advanced methods that have been reported on drug abuse websites and forums. Because FDA believes Category 1 testing should fully characterize the abuse-deterrent characteristics of an investigational formulation, Category 1 testing is time consuming and requires specialized laboratory resources as well as advanced knowledge of prescription medication abuse. Recent Advisory Committee meetings at FDA have shown that Category 1 tests play a critical role in FDA's evaluation of an investigational formulation. In this article, we will provide a general overview of the methods of manipulation and routes of administration commonly utilized by prescription drug abusers, how those methods and routes are evaluated in a laboratory setting, and discuss data intake, analysis, and reporting to satisfy FDA's Category 1 testing requirements.

  9. Five Common Glaucoma Tests

    Science.gov (United States)

    ... About Us Donate In This Section Five Common Glaucoma Tests en Español email Send this article to ... year or two after age 35. A Comprehensive Glaucoma Exam To be safe and accurate, five factors ...

  10. Scoring CT/HRCT findings among asbestos-exposed workers: effects of patient's age, body mass index and common laboratory test results

    Energy Technology Data Exchange (ETDEWEB)

    Vehmas, T.; Huuskonen, M.S. [Finnish Institute of Occupational Health, Department of Radiology, Helsinki (Finland); Kivisaari, L. [Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland); Jaakkola, M.S. [Finnish Institute of Occupational Health, Department of Radiology, Helsinki (Finland); University of Birmingham, Institute of Occupational and Environmental Medicine, Birmingham (United Kingdom)

    2005-02-01

    We studied the effects of age, body mass index (BMI) and some common laboratory test results on several pulmonary CT/HRCT signs. Five hundred twenty-eight construction workers (age 38-80, mean 63 years) were imaged with spiral and high resolution CT. Images were scored by three radiologists for solitary pulmonary nodules, signs indicative of fibrosis and emphysema, ground glass opacities, bronchial wall thickness and bronchiectasis. Multivariate statistical analyses were adjusted for smoking and asbestos exposure. Increasing age, blood haemoglobin value and erythrocyte sedimentation rate correlated positively with several HRCT signs. Increasing BMI was associated with a decrease in several signs, especially parenchymal bands, honeycombing, all kinds of emphysema and bronchiectasis. The latter finding might be due to the suboptimal image quality in obese individuals, which may cause suspicious findings to be overlooked. Background data, including patient's age and body constitution, should be considered when CT/HRCT images are interpreted. (orig.)

  11. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    Science.gov (United States)

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    Science.gov (United States)

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or 50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  13. Sandia Laboratories technical capabilities: testing

    International Nuclear Information System (INIS)

    Lundergan, C.D.

    1975-12-01

    The testing capabilities at Sandia Laboratories are characterized. Selected applications of these capabilities are presented to illustrate the extent to which they can be applied in research and development programs

  14. Total laboratory automation: Do stat tests still matter?

    Science.gov (United States)

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Sensitivity and Specificity of Clinical and Laboratory Otolith Function Tests.

    Science.gov (United States)

    Kumar, Lokesh; Thakar, Alok; Thakur, Bhaskar; Sikka, Kapil

    2017-10-01

    To evaluate clinic based and laboratory tests of otolith function for their sensitivity and specificity in demarcating unilateral compensated complete vestibular deficit from normal. Prospective cross-sectional study. Tertiary care hospital vestibular physiology laboratory. Control group-30 healthy adults, 20-45 years age; Case group-15 subjects post vestibular shwannoma excision or post-labyrinthectomy with compensated unilateral complete audio-vestibular loss. Otolith function evaluation by precise clinical testing (head tilt test-HTT; subjective visual vertical-SVV) and laboratory testing (headroll-eye counterroll-HR-ECR; vesibular evoked myogenic potentials-cVEMP). Sensitivity and specificity of clinical and laboratory tests in differentiating case and control subjects. Measurable test results were universally obtained with clinical otolith tests (SVV; HTT) but not with laboratory tests. The HR-ECR test did not indicate any definitive wave forms in 10% controls and 26% cases. cVEMP responses were absent in 10% controls.HTT test with normative cutoff at 2 degrees deviations from vertical noted as 93.33% sensitive and 100% specific. SVV test with normative cutoff at 1.3 degrees noted as 100% sensitive and 100% specific. Laboratory tests demonstrated poorer specificities owing primarily to significant unresponsiveness in normal controls. Clinical otolith function tests, if conducted with precision, demonstrate greater ability than laboratory testing in discriminating normal controls from cases with unilateral complete compensated vestibular dysfunction.

  16. Impact of Laboratory Test Use Strategies in a Turkish Hospital.

    Directory of Open Access Journals (Sweden)

    Fatma Meriç Yılmaz

    Full Text Available Eliminating unnecessary laboratory tests is a good way to reduce costs while maintain patient safety. The aim of this study was to define and process strategies to rationalize laboratory use in Ankara Numune Training and Research Hospital (ANH and calculate potential savings in costs.A collaborative plan was defined by hospital managers; joint meetings with ANHTA and laboratory professors were set; the joint committee invited relevant staff for input, and a laboratory efficiency committee was created. Literature was reviewed systematically to identify strategies used to improve laboratory efficiency. Strategies that would be applicable in local settings were identified for implementation, processed, and the impact on clinical use and costs assessed for 12 months.Laboratory use in ANH differed enormously among clinics. Major use was identified in internal medicine. The mean number of tests per patient was 15.8. Unnecessary testing for chloride, folic acid, free prostate specific antigen, hepatitis and HIV testing were observed. Test panel use was pinpointed as the main cause of overuse of the laboratory and the Hospital Information System test ordering page was reorganized. A significant decrease (between 12.6-85.0% was observed for the tests that were taken to an alternative page on the computer screen. The one year study saving was equivalent to 371,183 US dollars.Hospital-based committees including laboratory professionals and clinicians can define hospital based problems and led to a standardized approach to test use that can help clinicians reduce laboratory costs through appropriate use of laboratory tests.

  17. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  18. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  19. Laboratory development and testing of spacecraft diagnostics

    Science.gov (United States)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  20. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    Science.gov (United States)

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Test Anxiety, Computer-Adaptive Testing and the Common Core

    Science.gov (United States)

    Colwell, Nicole Makas

    2013-01-01

    This paper highlights the current findings and issues regarding the role of computer-adaptive testing in test anxiety. The computer-adaptive test (CAT) proposed by one of the Common Core consortia brings these issues to the forefront. Research has long indicated that test anxiety impairs student performance. More recent research indicates that…

  2. Iowa Central Quality Fuel Testing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Land Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.

  3. Test plan for ISV laboratory-pyrolysis testing

    Energy Technology Data Exchange (ETDEWEB)

    McAtee, R.E.

    1991-09-01

    The objective of the laboratory-pyrolysis studies is to obtain information on the high temperature (< 1200{degree}C) degradation and alteration of organic chemicals and materials similar to those found in the Radioactive Waste Management Complex, Pit 9. This test plan describes experimental procedures, sampling and analysis strategy, sampling procedures, sample control, and document management. It addresses safety issues in the experimental apparatus and procedures, personal training, and hazardous waste disposal. Finally, it describes the data quality objectives using the EPA tiered approach to treatability studies to define where research/scoping tests fit into these studies and the EPA analytical levels required for the tests.

  4. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    Science.gov (United States)

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  5. Manual on laboratory testing for uranium ore processing

    International Nuclear Information System (INIS)

    1990-01-01

    Laboratory testing of uranium ores is an essential step in the economic evaluation of uranium occurrences and in the development of a project for the production of uranium concentrates. Although these tests represent only a small proportion of the total cost of a project, their proper planning, execution and interpretation are of crucial importance. The main purposes of this manual are to discuss the objectives of metallurgical laboratory ore testing, to show the specific role of these tests in the development of a project, and to provide practical instructions for performing the tests and for interpreting their results. Guidelines on the design of a metallurgical laboratory, on the equipment required to perform the tests and on laboratory safety are also given. This manual is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. A report on the Significance of Mineralogy in the Development of Flowsheets for Processing Uranium Ores (Technical Reports Series No. 196, 1980) and an instruction manual on Methods for the Estimation of Uranium Ore Reserves (No. 255, 1985) have already been published. 17 refs, 40 figs, 17 tabs

  6. Transaction processing in the common node of a distributed function laboratory computer system

    International Nuclear Information System (INIS)

    Stubblefield, F.W.; Dimmler, D.G.

    1975-01-01

    A computer network architecture consisting of a common node processor for managing peripherals and files and a number of private node processors for laboratory experiment control is briefly reviewed. Central to the problem of private node-common node communication is the concept of a transaction. The collection of procedures and the data structure associated with a transaction are described. The common node properties assigned to a transaction and procedures required for its complete processing are discussed. (U.S.)

  7. Centrifugal contractors for laboratory-scale solvent extraction tests

    International Nuclear Information System (INIS)

    Leonard, R.A.; Chamberlain, D.B.; Conner, C.

    1995-01-01

    A 2-cm contactor (minicontactor) was developed and used at Argonne National Laboratory for laboratory-scale testing of solvent extraction flowsheets. This new contactor requires only 1 L of simulated waste feed, which is significantly less than the 10 L required for the 4-cm unit that had previously been used. In addition, the volume requirements for the other aqueous and organic feeds are reduced correspondingly. This paper (1) discusses the design of the minicontactor, (2) describes results from having applied the minicontactor to testing various solvent extraction flowsheets, and (3) compares the minicontactor with the 4-cm contactor as a device for testing solvent extraction flowsheets on a laboratory scale

  8. 19 CFR 151.54 - Testing by Customs laboratory.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance with...

  9. Ky. Road-Tests Common Core

    Science.gov (United States)

    Ujifusa, Andrew

    2012-01-01

    Results from new state tests in Kentucky--the first in the nation explicitly tied to the Common Core State Standards--show that the share of students scoring "proficient" or better in reading and math dropped by roughly a third or more in both elementary and middle school the first year the tests were given. Kentucky in 2010 was the…

  10. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    Science.gov (United States)

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  11. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  12. Laboratory testing improves diagnosis and treatment outcomes in primary health care facilities

    Directory of Open Access Journals (Sweden)

    Jane Y. Carter

    2012-10-01

    Setting: Six rural health centres in Kenya. Design: Cross-sectional study to observe change in diagnosis and treatment made by clinical officers after laboratory testing in outpatients attending six rural health centres in Kenya. Subject: The diagnosis and treatment of 1134 patients attending outpatient services in six rural health centres were compared before and after basic laboratory testing. Essential clinical diagnostic equipment and laboratory tests were established at each health centre. Clinical officers and laboratory technicians received on-site refresher training in good diagnostic practices and laboratory procedures before the study began. Results: Laboratory tests were ordered on 704 (62.1% patients. Diagnosis and treatment were changed in 45% of tested patients who returned with laboratory results (21% of all patients attending the clinics. 166 (23.5% patients did not return to the clinician for a final diagnosis and management decision after laboratory testing. Blood slide examination for malaria parasites, wet preparations, urine microscopy and stool microscopy resulted in most changes to diagnosis. There was no significant change in drug costs after laboratory testing. The greatest changes in numbers of recorded diseases following laboratory testing was for intestinal worms (53% and malaria (21%. Conclusion: Effective use of basic laboratory tests at primary health care level significantly improves diagnosis and patient treatment. Use of laboratory testing can be readily incorporated into routine clinical practice. On-site refresher training is an effective means of improving the quality of patient care and communication between clinical and laboratory staff.

  13. 222-S LABORATORY FUME HOOD TESTING STUDY

    International Nuclear Information System (INIS)

    RUELAS, B.H.

    2007-01-01

    The 222-S Laboratory contains 155 active fume hoods that are used to support analytical work with radioactive and/or toxic materials. The performance of a fume hood was brought into question after employees detected odors in the work area while mixing chemicals within the subject fume hood. Following the event, testing of the fume hood was conducted to assess the performance of the fume hood. Based on observations from the testing, it was deemed appropriate to conduct performance evaluations of other fume hoods within the laboratory

  14. Closing the brain-to-brain loop in laboratory testing.

    Science.gov (United States)

    Plebani, Mario; Lippi, Giuseppe

    2011-07-01

    Abstract The delivery of laboratory services has been described 40 years ago and defined with the foremost concept of "brain-to-brain turnaround time loop". This concept consists of several processes, including the final step which is the action undertaken on the patient based on laboratory information. Unfortunately, the need for systematic feedback to improve the value of laboratory services has been poorly understood and, even more risky, poorly applied in daily laboratory practice. Currently, major problems arise from the unavailability of consensually accepted quality specifications for the extra-analytical phase of laboratory testing. This, in turn, does not allow clinical laboratories to calculate a budget for the "patient-related total error". The definition and use of the term "total error" refers only to the analytical phase, and should be better defined as "total analytical error" to avoid any confusion and misinterpretation. According to the hierarchical approach to classify strategies to set analytical quality specifications, the "assessment of the effect of analytical performance on specific clinical decision-making" is comprehensively at the top and therefore should be applied as much as possible to address analytical efforts towards effective goals. In addition, an increasing number of laboratories worldwide are adopting risk management strategies such as FMEA, FRACAS, LEAN and Six Sigma since these techniques allow the identification of the most critical steps in the total testing process, and to reduce the patient-related risk of error. As a matter of fact, an increasing number of laboratory professionals recognize the importance of understanding and monitoring any step in the total testing process, including the appropriateness of the test request as well as the appropriate interpretation and utilization of test results.

  15. Clinical Laboratory Tests in Some Acute Exogenous Poisonings.

    Science.gov (United States)

    Tufkova, Stoilka G; Yankov, Ivan V; Paskaleva, Diana A

    2017-09-01

    There is no specific toxicological screening of clinical laboratory parameters in clinical toxicology when it comes to acute exogenous poisoning. To determine routine clinical laboratory parameters and indicators for assessment of vital functions in patients with acute intoxications. One hundred and fifty-three patients were included in the present study. They were hospitalized in the Department of Clinical Toxicology at St. George University Hospital, Plovdiv for cerebral toxicity inducing medication (n = 45), alcohol (n = 40), heroin abuse (n = 33). The controls were 35. The laboratory tests were conducted in compliance with the standards of the clinical laboratory. We used the following statistical analyses: analysis of variance (the ucriterion of normal distribution, the Student's t-test, dispersion analysis based on ANOVA) and non-parametric analysis. Based on the routine hematological parameters with statistically significant changes in three groups of poisoning are: red blood cells, hematocrit, hemoglobin (except alcohol intoxication) and leukocytes. We found statistically significant changes in serum total protein, sodium and bilirubin. The highest statistical significance is the increased activity of AST and ALT. We present a model for selection of clinical laboratory tests for severe acute poisoning with modern equipment under standardized conditions. The results of the study suggest that the clinical laboratory constellation we used can be used as a mandatory element in the diagnosis of moderate and severe intoxication with the mentioned toxic substances.

  16. Progression of Common Variable Immunodeficiency Interstitial Lung Disease Accompanies Distinct Pulmonary and Laboratory Findings.

    Science.gov (United States)

    Maglione, Paul J; Overbey, Jessica R; Cunningham-Rundles, Charlotte

    2015-01-01

    Common variable immunodeficiency may be complicated by interstitial lung disease, which leads to worsened morbidity and mortality in some. Although immunomodulatory treatment has efficacy, choice of patient, duration of treatment, and long-term follow-up are not available. Interstitial lung disease appears stable in certain instances, so it is not known whether all patients will develop progressive disease or require immunomodulatory therapy. This study aims to determine if all common variable immunodeficiency patients with interstitial lung disease have physiological worsening, and if clinical and/or laboratory parameters may correlate with disease progression. A retrospective review of medical records at Mount Sinai Medical Center in New York was conducted for referred patients with common variable immunodeficiency, CT scan-confirmed interstitial lung disease, and periodic pulmonary function testing covering 20 or more months before immunomodulatory therapy. Fifteen patients were identified from the retrospective review and included in this study. Of the 15 patients with common variable immunodeficiency, 9 had physiological worsening of interstitial lung disease adapted from consensus guidelines, associated with significant reductions in forced expiratory volume in 1 second, forced vital capacity, and diffusion capacity of the lung for carbon monoxide. Those with progressive lung disease also had significantly lower mean immunoglobulin G levels, greater increases and highest levels of serum immunoglobulin M (IgM), and more significant thrombocytopenia. Interstitial lung disease resulted in physiological worsening in many, but not all subjects, and was associated with suboptimal immunoglobulin G replacement. Those with worsening pulmonary function tests, elevated IgM, and severe thrombocytopenic episodes appear to be at highest risk for progressive disease. Such patients may benefit from immunomodulatory treatment. Copyright © 2015 American Academy of Allergy

  17. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  18. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    Science.gov (United States)

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  19. A new predictive indicator for development of pressure ulcers in bedridden patients based on common laboratory tests results.

    Science.gov (United States)

    Hatanaka, N; Yamamoto, Y; Ichihara, K; Mastuo, S; Nakamura, Y; Watanabe, M; Iwatani, Y

    2008-04-01

    Various scales have been devised to predict development of pressure ulcers on the basis of clinical and laboratory data, such as the Braden Scale (Braden score), which is used to monitor activity and skin conditions of bedridden patients. However, none of these scales facilitates clinically reliable prediction. To develop a clinical laboratory data-based predictive equation for the development of pressure ulcers. Subjects were 149 hospitalised patients with respiratory disorders who were monitored for the development of pressure ulcers over a 3-month period. The proportional hazards model (Cox regression) was used to analyse the results of 12 basic laboratory tests on the day of hospitalisation in comparison with Braden score. Pressure ulcers developed in 38 patients within the study period. A Cox regression model consisting solely of Braden scale items showed that none of these items contributed to significantly predicting pressure ulcers. Rather, a combination of haemoglobin (Hb), C-reactive protein (CRP), albumin (Alb), age, and gender produced the best model for prediction. Using the set of explanatory variables, we created a new indicator based on a multiple logistic regression equation. The new indicator showed high sensitivity (0.73) and specificity (0.70), and its diagnostic power was higher than that of Alb, Hb, CRP, or the Braden score alone. The new indicator may become a more useful clinical tool for predicting presser ulcers than Braden score. The new indicator warrants verification studies to facilitate its clinical implementation in the future.

  20. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  1. Laboratory procedures for waste form testing

    International Nuclear Information System (INIS)

    Mast, E.S.

    1994-01-01

    The 100 and 300 areas of the Hanford Site are included on the US Environmental Protection Agencies (EPA) National Priorities List under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Soil washing is a treatment process that is being considered for the remediation of the soil in these areas. Contaminated soil washing fines can be mixed or blended with cementations materials to produce stable waste forms that can be used for beneficial purposes in mixed or low-level waste landfills, burial trenches, environmental restoration sites, and other applications. This process has been termed co-disposal. The Co-Disposal Treatability Study Test Plan is designed to identify a range of cement-based formulations that could be used in disposal efforts in Hanford in co-disposal applications. The purpose of this document is to provide explicit procedural information for the testing of co-disposal formulations. This plan also provides a discussion of laboratory safety and quality assurance necessary to ensure safe, reproducible testing in the laboratory

  2. Laboratory procedures for waste form testing

    Energy Technology Data Exchange (ETDEWEB)

    Mast, E.S.

    1994-09-19

    The 100 and 300 areas of the Hanford Site are included on the US Environmental Protection Agencies (EPA) National Priorities List under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Soil washing is a treatment process that is being considered for the remediation of the soil in these areas. Contaminated soil washing fines can be mixed or blended with cementations materials to produce stable waste forms that can be used for beneficial purposes in mixed or low-level waste landfills, burial trenches, environmental restoration sites, and other applications. This process has been termed co-disposal. The Co-Disposal Treatability Study Test Plan is designed to identify a range of cement-based formulations that could be used in disposal efforts in Hanford in co-disposal applications. The purpose of this document is to provide explicit procedural information for the testing of co-disposal formulations. This plan also provides a discussion of laboratory safety and quality assurance necessary to ensure safe, reproducible testing in the laboratory.

  3. Use of laboratory test results in patient management by clinicians in Malawi.

    Science.gov (United States)

    Moyo, Kundai; Porter, Carol; Chilima, Ben; Mwenda, Reuben; Kabue, Mark; Zungu, Lutho; Sarr, Abdoulaye

    2015-11-18

    Malawi has a high burden of infectious disease. The expansion of programmes targeting these diseases requires a strong laboratory infrastructure to support both diagnosis and treatment. To assess the use of laboratory test results in patient management and to determine the requirements for improving laboratory services. A cross-sectional study was conducted in 2012 to survey practising clinicians. Two hospitals were purposively selected for observations of clinicians ordering laboratory tests. Twelve management-level key informants were interviewed. Descriptive statistics were conducted. A total of 242 clinicians were identified and 216 (89%) were interviewed. Of these, 189 (87%) reported doubting laboratory test results at some point. Clinicians most often doubted the quality of haematology (67%), followed by malaria (53%) and CD4 (22%) test results. A total of 151 (70%) clinicians reported using laboratory tests results in patient management. Use of laboratory test results at all times in patient management varied by the type of health facility ( P management. Key informants reported that the quality of laboratory services was good and useful, but that services were often unavailable. Gaps in the public laboratory system were evident. Key recommendations to enhance the use of laboratory test results in patient management were to strengthen the supply chain, reduce turn-around times, improve the test menu and improve the laboratory infrastructure.

  4. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  5. Inadequate Information in Laboratory Test Requisition in a Tertiary ...

    African Journals Online (AJOL)

    Objectives: This study examined the pattern of deficiencies in the laboratory test requisition by doctors at the University of Benin Teaching Hospital, Benin City, Nigeria, with a view to suggesting strategies of reducing error rates in laboratory test requisition. Materials and Method: The study generated data through ...

  6. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30.

  7. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    International Nuclear Information System (INIS)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30

  8. Pre-Clinical Traumatic Brain Injury Common Data Elements: Toward a Common Language Across Laboratories.

    Science.gov (United States)

    Smith, Douglas H; Hicks, Ramona R; Johnson, Victoria E; Bergstrom, Debra A; Cummings, Diana M; Noble, Linda J; Hovda, David; Whalen, Michael; Ahlers, Stephen T; LaPlaca, Michelle; Tortella, Frank C; Duhaime, Ann-Christine; Dixon, C Edward

    2015-11-15

    Traumatic brain injury (TBI) is a major public health issue exacting a substantial personal and economic burden globally. With the advent of "big data" approaches to understanding complex systems, there is the potential to greatly accelerate knowledge about mechanisms of injury and how to detect and modify them to improve patient outcomes. High quality, well-defined data are critical to the success of bioinformatics platforms, and a data dictionary of "common data elements" (CDEs), as well as "unique data elements" has been created for clinical TBI research. There is no data dictionary, however, for preclinical TBI research despite similar opportunities to accelerate knowledge. To address this gap, a committee of experts was tasked with creating a defined set of data elements to further collaboration across laboratories and enable the merging of data for meta-analysis. The CDEs were subdivided into a Core module for data elements relevant to most, if not all, studies, and Injury-Model-Specific modules for non-generalizable data elements. The purpose of this article is to provide both an overview of TBI models and the CDEs pertinent to these models to facilitate a common language for preclinical TBI research.

  9. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    Science.gov (United States)

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  10. To test or not to test? Laboratory support for the diagnosis of Lyme borreliosis

    DEFF Research Database (Denmark)

    Dessau, Ram B; van Dam, Alje P; Fingerle, Volker

    2018-01-01

    rational use of laboratory testing in patients with clinically suspected Lyme borreliosis. SOURCES: This is a narrative review combining various aspects of the clinical and laboratory diagnosis with an educational purpose. The literature search was based on existing systematic reviews, national...... and international guidelines and supplemented with specific citations. IMPLICATIONS: The main recommendations according to current European case definitions for Lyme borreliosis are as follows: Typical erythema migrans should be diagnosed clinically and does not require laboratory testing, the diagnosis of Lyme...

  11. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    Science.gov (United States)

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  13. Towards a rational antimicrobial testing policy in the laboratory.

    Science.gov (United States)

    Banaji, N; Oommen, S

    2011-01-01

    Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  14. Common Systems Integration Lab (CSIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Common Systems Integration Lab (CSIL)supports the PMA-209 Air Combat Electronics Program Office. CSIL also supports development, test, integration and life cycle...

  15. Inter-laboratory proficiency tests to detect viral fish diseases

    DEFF Research Database (Denmark)

    Kahns, Søren; Nicolajsen, Nicole; Skall, Helle Frank

    An inter-laboratory proficiency test has ben provided by the European Community Laboratory (CRL) for Fish Diseases every year since 1996. The test is provided to all European National Reference Laboratories (NRLs) that are obliged to participate and to a limited number of non-European NRLs, making......) but also to assess their ability to differentiate other fish viruses as spring viraemia of carp virus, infectious pancreatic necrosis virus, perch rhabdovirus etc. Five coded ampoules are provided to participants containing lyophilised supernatant from infected cell cultures. The CRL collect the data...

  16. Laboratory tests of hydraulic fracturing and swell healing

    DEFF Research Database (Denmark)

    Thunbo, Christensen Claes; Foged, Christensen Helle; Foged, Niels

    1998-01-01

    New laboratory test set-ups and test procedures are described - for testing the formation of hydraulically induced fractures as well as the potential for subsequent fracture closurefrom the relase of a swelling potential. The main purpose with the tests is to provide information on fracturing str...

  17. Mobile Energy Laboratory energy-efficiency testing programs

    International Nuclear Information System (INIS)

    Parker, G.B.; Currie, J.W.

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies

  18. Mobile Energy Laboratory energy-efficiency testing programs

    Energy Technology Data Exchange (ETDEWEB)

    Parker, G B; Currie, J W

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies.

  19. Towards a rational antimicrobial testing policy in the laboratory

    Directory of Open Access Journals (Sweden)

    N Banaji

    2011-01-01

    Full Text Available Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital′s antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  20. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    Science.gov (United States)

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  1. Stochastic optimization of laboratory test workflow at metallurgical testing centers

    Directory of Open Access Journals (Sweden)

    F. Tošenovský

    2016-10-01

    Full Text Available The objective of the paper is to present a way to shorten the time required to perform laboratory tests of materials in metallurgy. The paper finds a relation between the time to perform a test of materials and the number of technicians carrying out the test. The relation can be used to optimize the number of technicians. The approach is based on probability theory, as the amount of material to be tested is unknown in advance, and uses powerful modelling techniques involving the generalized estimating equations.

  2. Quality assurance of laboratory work and clinical use of laboratory tests in general practice in norway: a survey.

    Science.gov (United States)

    Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre

    2011-09-01

    Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.

  3. The laboratory information float, time-based competition, and point-of-care testing.

    Science.gov (United States)

    Friedman, B A

    1994-01-01

    A new term, the laboratory information float, should be substituted for turnaround-time when evaluating the performance of the clinical laboratory because it includes the time necessary to make test results both available (ready to use) and accessible (easy to use) to clinicians ordering tests. The laboratory information float can be greatly reduced simply by telescoping the analytic phase of laboratory testing into the preanalytic phase. Significant costs are incurred by such a change, some of which can be reduced by developing a mobile clinical laboratory (sometimes referred to as a "lab-on-a-slab" or "rolling thunder") to transport the analytic devices directly to patient care units. The mobile clinical laboratory should be equipped with an integrated personal computer that can communicate continuously with the host laboratory information system and achieve some semblance of continuous flow processing despite test performance in point-of-care venues. Equipping clinicians with palmtop computers will allow the mobile clinician to access test results and order tests on the run. Such devices can be easily configured to operate in a passive mode, accessing relevant information automatically instead of forcing clinicians to query the laboratory information system periodically for the test results necessary to render care to their patients. The laboratory information float of the year 2,000 will surely be measured in minutes through the judicious deployment of relevant technology such as mobile clinical laboratories and palmtop computers.

  4. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    Science.gov (United States)

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  5. Laboratory testing of the in-well vapor-stripping system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Francois, O.

    1996-03-01

    The Volatile organic Compounds-Arid Integrated Demonstration (VOC-Arid ID) was implemented by the US Department of Energy's (DOE's) Office of Technology Development to develop and test new technologies for the remediation of organic chemicals in the subsurface. One of the technologies being tested under the VOC-Arid ID is the in-well vapor-stripping system. The in-well vapor-stripping concept was initially proposed by researchers at Stanford University and is currently under development through a collaboration between workers at Stanford University and DOE's Pacific Northwest National Laboratory. The project to demonstrate the in-well vapor-stripping technology is divided into three phases: (1) conceptual model and computer simulation, (2) laboratory testing, and (3) field demonstration. This report provides the methods and results of the laboratory testing in which a full-scale replica was constructed and tested above ground in a test facility located at DOE's Hanford Site, Washington. The system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase

  6. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  7. Using fee-for-service testing to generate revenue for the 21st century public health laboratory.

    Science.gov (United States)

    Loring, Carol; Neil, R Brock; Gillim-Ross, Laura; Bashore, Matthew; Shah, Sandip

    2013-01-01

    The decrease in appropriations for state public health laboratories (SPHLs) has become a major concern as tax revenues and, subsequently, state and federal funding, have decreased. These reductions have forced SPHLs to pursue revenue-generating opportunities to support their work. We describe the current state of funding in a sampling of SPHLs and the challenges these laboratories face as they implement or expand fee-for-service testing. We conducted surveys of SPHLs to collect data concerning laboratory funding sources, test menus, fee-for-service testing, and challenges to implementing fee-for-service testing. Most SPHLS receive funding through three revenue sources: state appropriation, federal funding, and fee-for-service testing (cash funds). Among SPHLs, state appropriations ranged from $0 to more than $6 per capita, federal funding ranged from $0.10 to $5 per capita, and revenue from fee-for-service testing ranged from $0 to $4 per capita. The tests commonly performed on a fee-for-service basis included assays for sexually transmitted diseases, mycobacterial cultures, newborn screening, and water testing. We found that restrictive legislation, staffing shortages, inadequate software for billing fee-for-service testing, and regulations on how SPHLs use their generated revenue are impediments to implementing fee-for-service testing. Some SPHLs are considering implementing or expanding fee-for-service testing as a way to recapture funds lost as a result of state and federal budget cuts. This analysis revealed many of the obstacles to implementing fee-for-service testing in SPHLs and the potential impact on SPHLs of continued decreases in funding.

  8. Recommended procedures for performance testing of radiobioassay laboratories: Volume 1, Quality assurance

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed in response to a concern expressed by the US Department of Energy and US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped define responsibilities and develop procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria for quality assurance at bioassay laboratories. This report recommends elements of quality assurance and quality control responsibilities for the bioassay performance-testing laboratory program, including the qualification and performance of personnel and the calibration, certification, and performance of equipment. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 15 refs

  9. Pending laboratory tests and the hospital discharge summary in patients discharged to sub-acute care.

    Science.gov (United States)

    Walz, Stacy E; Smith, Maureen; Cox, Elizabeth; Sattin, Justin; Kind, Amy J H

    2011-04-01

    Previous studies have noted a high (41%) prevalence and poor discharge summary communication of pending laboratory (lab) tests at the time of hospital discharge for general medical patients. However, the prevalence and communication of pending labs within a high-risk population, specifically those patients discharged to sub-acute care (i.e., skilled nursing, rehabilitation, long-term care), remains unknown. To determine the prevalence and nature of lab tests pending at hospital discharge and their inclusion within hospital discharge summaries, for common sub-acute care populations. Retrospective cohort study. Stroke, hip fracture, and cancer patients discharged from a single large academic medical center to sub-acute care, 2003-2005 (N = 564) Pending lab tests were abstracted from the laboratory information system (LIS) and from each patient's discharge summary, then grouped into 14 categories and compared. Microbiology tests were sub-divided by culture type and number of days pending prior to discharge. Of sub-acute care patients, 32% (181/564) were discharged with pending lab tests per the LIS; however, only 11% (20/181) of discharge summaries documented these. Patients most often left the hospital with pending microbiology tests (83% [150/181]), particularly blood and urine cultures, and reference lab tests (17% [30/181]). However, 82% (61/74) of patients' pending urine cultures did not have 24-hour preliminary results, and 19% (13/70) of patients' pending blood cultures did not have 48-hour preliminary results available at the time of hospital discharge. Approximately one-third of the sub-acute care patients in this study had labs pending at discharge, but few were documented within hospital discharge summaries. Even after considering the availability of preliminary microbiology results, these omissions remain common. Future studies should focus on improving the communication of pending lab tests at discharge and evaluating the impact that this improved

  10. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  11. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  12. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  13. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    Science.gov (United States)

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (Pquality assurance (Pquality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, Pquality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  14. Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.

    Science.gov (United States)

    Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K

    2014-02-01

    Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P reimbursement volumes increased for most of the selected tests, other tests exhibited statistically significant downward trends in annual reimbursement volumes. The observed

  15. Antiphospholipid Syndrome Laboratory Testing and Diagnostic Strategies

    Science.gov (United States)

    Ortel, Thomas L.

    2016-01-01

    The Antiphospholipid Syndrome (APS) is diagnosed in patients with recurrent thromboembolic events and/or pregnancy loss in the presence of persistent laboratory evidence for antiphospholipid antibodies. Diagnostic tests for the detection of antiphospholipid antibodies include laboratory assays that detect anticardiolipin antibodies, lupus anticoagulants, and anti-β2-glycoprotein I antibodies. These assays have their origins beginning more than sixty years ago, with the identification of the biologic false positive test for syphilis, the observation of ‘circulating anticoagulants’ in certain patients with systemic lupus erythematosus, the identification of cardiolipin as a key component in the serologic test for syphilis, and the recognition and characterization of a ‘cofactor’ for antibody binding to phospholipids. Although these assays have been used clinically for many years, there are still problems with the accurate diagnosis of patients with this syndrome. For example, lupus anticoagulant testing can be difficult to interpret in patients receiving anticoagulant therapy, but most patients with a thromboembolic event will already be anticoagulated before the decision to perform the tests has been made. In addition to understanding limitations of the assays, clinicians also need to be aware of which patients should be tested and not obtain testing on patients unlikely to have APS. New tests and diagnostic strategies are in various stages of development and should help improve our ability to accurately diagnose this important clinical disorder. PMID:22473619

  16. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  17. Evaluation of three oil spill laboratory dispersant effectiveness tests

    International Nuclear Information System (INIS)

    Sullivan, D.; Farlow, J.; Sahatjian, K.A.

    1993-01-01

    Chemical dispersants can be used to reduce the interfacial tension of floating oil slicks so that the oils disperse more rapidly into the water column and thus pose less of a threat to shorelines, birds, and marine mammals. The laboratory test currently specified in federal regulations to measure dispersant effectiveness is not especially easy or inexpensive, and generates a rather large quantity of oily waste water. This paper describes the results of an effort by the EPA to identify a more suitable laboratory dispersant effectiveness test. EPA evaluated three laboratory methods: the Revised Standard Dispersant Effectiveness Test currently used (and required by regulation) in the United States, the swirling flask test (developed by Environment Canada), and the IFP-dilution test (used in france and other European countries). Six test oils and three dispersants were evaluated; dispersants were applied to the oil at an average 1:10 ratio (dispersant to oil) for each of the three laboratory methods. Screening efforts were used to focus on the most appropriate oil/dispersant combination for detailed study. A screening criterion was established that required a combination that gave at least 20% effectiveness results. The selected combination turned out to be Prudhoe Bay crude oil and the dispersant Corexit 9527. This combination was also most likely to be encountered in US coastal waters. The EPA evaluation concluded that the three tests gave similar precision results, but that the swirling flask test was fastest, cheapest, simplest, and required least operator skill. Further, EPA is considering conducting the dispersant effectiveness test itself, rather than having data submitted by a dispersant manufacturer, and establishing an acceptability criterion (45% efficiency) which would have to be met before a dispersant could be placed on the Product Schedule of the National Contingency Plan (NCP)

  18. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  19. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States.

    Science.gov (United States)

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin

    2016-07-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.

  20. Chapter 31: Common in vitro tests for allergy and immunology.

    Science.gov (United States)

    Makhija, Melanie; O'Gorman, Maurice R G

    2012-01-01

    Allergen-specific IgE antibody is the most commonly ordered in vitro test in the practice of allergy and is used to diagnose type I hypersensitivity reactions to foods or reactivity to aeroallergens in patients with relative contraindications to skin-prick testing such as dermatographism. The Phadebas radioallergosorbent test (RAST; Pharmacia, Uppsala, Sweden) was the first assay reported for the detection of the allergen-specific IgE antibody. In a RAST, antigen (allergen) is bound to a solid phase, such as a paper disk, and then incubated with human serum. A buffer wash removes unbound serum proteins, and radiolabeled anti-human IgE is added to detect bound IgE, if present. The results are reported in arbitrary units of IgE per milliliter of serum. The term RAST was originally a brand name but it is now often used colloquially (and incorrectly) to describe any in vitro assay for allergen-specific IgE. Total serum IgE can be measured and is helpful in determining atopic presentations such as in allergic bronchopulmonary aspergillosis or in patients with persistent asthma who are candidates for monoclonal anti-IgE antibody therapy with, omalizumab. In patients with recurrent bacterial infections of the sinopulmonary tract, the basic humoral immune system testing includes measuring quantitative immunoglobulins (IgG, IgA, and IgM) and comparing them to age-matched normal ranges. Most clinical laboratories use nephelometry to measure immunoglobulin levels quantitatively. Nephelometry detects either the rate or the end point of soluble immune complex formation (the IgG in sera complexes with an anti-IgG antibody forming a classic immunoprecipitation reaction) by monitoring the scatter of transmitted light. The most common method for the screening of cellular immunodeficiency involved the measurement of the absolute and relative representation of the major lymphocyte subsets, T-cells, T-helper cells, T-cytotoxic cells, B-cells and NK-cells.

  1. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... Condition: Laboratories performing high complexity testing; clinical consultant. The laboratory must have a... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID...

  2. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  3. AUDILAB: a knowledge-based quality audit simulator for testing laboratories.

    Science.gov (United States)

    Brai, A; Garnerin, P

    1997-05-01

    In order to obtain an accreditation, a laboratory must be prepared to provide a point-by-point check of various activities against the chosen reference standard, both from a general point of view and in relation to details of application. This paper describes AUDILAB, a computerized simulator accessible by network, able to provide testing laboratories with realistic quality audits performed in a customized way. AUDILAB establishes a detailed list of strengths (compliance with corresponding requirements of established standards) and weaknesses (improvements needed for laboratory's accreditation). The standard used by AUDILAB is the EN 45001 "General criteria for the operation of testing laboratories". A preliminary validation has already been completed. AUDILAB became operational in September 1993.

  4. Accreditation of testing laboratories in CNEA (National Atomic Energy Commission)

    International Nuclear Information System (INIS)

    Piacquadio, N.H.; Casa, V.A.; Palacios, T.A.

    1993-01-01

    The recognition of the technical capability of a testing laboratory is carried out by Laboratory Accreditation Bodies as the result of a satisfactory evaluation and the systematic follow up of the certified qualification. In Argentina the creation of a National Center for the Accreditation of Testing Laboratories, as a first step to assess a National Accreditation System is currently projected. CNEA, as an institution involved in technological projects and in the development and production of goods and services, has adopted since a long time ago quality assurance criteria. One of their requirements is the qualification of laboratories. Due to the lack of a national system, a Committee for the Qualification of Laboratories was created jointly by the Research and Development and Nuclear Fuel Cycle Areas with the responsibility of planning and management of the system evaluation and the certification of the quality of laboratories. The experience in the above mentioned topics is described in this paper. (author)

  5. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Laboratory

    Science.gov (United States)

    Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.

    2007-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  6. Approaches to quality management and accreditation in a genetic testing laboratory

    Science.gov (United States)

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  7. Development of New, Low-Head Hydropower Turbine - Modeling & Laboratory Test DE-EE0005426

    Energy Technology Data Exchange (ETDEWEB)

    Krouse, Wayne [Hydro Green Energy, Westmont, IL (United States)

    2014-12-05

    Hydro Green Energy, LLC (HGE) will complete the design, fabrication and laboratory testing of a scaled, vertically stackable, low-head hydropower turbine called the Modular Bulb Turbine (MBT). HGE will also complete a summary report that includes the laboratory testing results and analysis of the tests. Project Goals: Design, model and test modular bulb turbine for installation in numerous HGE low-head hydropower projects at non-powered USACE dams. Project Results: The sub-scale prototype was tested successfully at a leading US hydraulic laboratory. Laboratory data results agreed well with predicted results from numerical modeling.

  8. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults

    OpenAIRE

    Kim, Sung Ryeol; Park, Hye Jung; Park, Kyung Hee; Lee, Jae-Hyun; Park, Jung-Won

    2016-01-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was dete...

  9. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  10. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    Science.gov (United States)

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  11. Application Anti Microbial Activity Test and Direct Inoculation of Urinary Specimen Test to Increase the Quality of Results and Decrease the Production Cost in Clinical Microbiology Laboratory, Sanglah General Hospital Hospital, Bali-Indonesia

    Directory of Open Access Journals (Sweden)

    Nyoman Sri-Budayanti

    2012-05-01

    Full Text Available Objective: Urinary tract infection (UTI is the most common bacterial infection in general practice and in hospitals. Fast and accurate urine culture and sensitivity test are needed for adequate therapy. Anti Microbial Activity test (AMA test that is used to detect the presence of antibiotics in urine specimens is not commonly used in clinical microbiology laboratories. Some laboratories are still using indirect inoculation technique using enriched media before inoculating onto the agar media. The aim of this research is to compare results of urinary examination of direct inoculation technique with AMA test with indirect inoculation technique without AMA test.Methods: A number of 210 urine specimens were collected in Clinical Microbiology Laboratory at Sanglah General Hospital within a time period between 16 June until 16 July 2009.Results: Antibiotics were detected in 40% of the urinary specimens; whereas 48.1% showed no evidence of UTI, that is negative AMA test and sterile urinary culture or colony growth < 105 CFU/ml. Only 11.9% of the specimens indicates urinary tract infections. The examination can be completed within 2-3 days which is shorter than indirect inoculation test which require 5-7 days. Direct inoculation technique can reduce the cost of production three-fold the costs require for an indirect inoculation test.Conclusions: Application of AMA test and direct inoculation technique can give results more rapidly, reliable and useful for clinicians. This also decrease the laboratory’s cost of production.

  12. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    Science.gov (United States)

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  13. Development of a Laboratory Test Procedure to Evaluate Tack Coat Performance

    OpenAIRE

    YILDIRIM, Yetkin; SMIT, André de Fortier; KORKMAZ, Armagan

    2014-01-01

    A laboratory testing procedure is presented, the results of which may be used for determining the best combination of tack coat type, mixture type, and application rate to be applied in the field for optimum performance. Tack coat related performance results were determined from Hamburg wheel tracking and simple shear tests on laboratory prepared specimens. This study was undertaken to evaluate the shear strength performance of tack coats under laboratory-controlled conditions. The ...

  14. Laboratory tests for diagnosis of food allergy: advantages, disadvantages and future perspectives.

    Science.gov (United States)

    Moneret-Vautrin, D A; Kanny, G; Frémont, S

    2003-04-01

    Numerous biological tests point to the diagnosis of food sensitization: detection of specific IgEs by Rast techniques, multi-detection assays, immunoblotting, screening of basophil activation (BAT or FAST), assays for leukotriene LTC4 release (CAST), measurement of plasma histamine, serum tryptase, serum ECP, urinary EDN, completed by mannitol-lactulose test evaluating intestinal permeability, assay of fecal IgEs, Rast for specific IgG4. Primary screening for anti-food IgEs by multi-detection assays seeks justification from insufficient clinical data and false positive tests are common in patients sensitized to pollens or latex, on account of in vitro cross reactivities (CR). Multiple CR explain positive Rast to vegetal food allergens in such patients. Biological tests should not be performed as the first line of diagnosis. In vivo sensitisation is assessed by positive prick-tests, demonstrating the bivalence of allergens, as well as the affinity of specific IgEs, two conditions necessary to bridge membrane bound specific IgEs, leading to the release of mediators. Prick-tests are closer to clinical symptoms than biological tests. However, the diagnosis of food allergy is based on standardised oral challenges. Exceptions are high levels of specific IgEs to egg (> 6 kUl/l), peanut (> 15 kUl/l), fish (> 20 kUl/l) and milk (> 32 kUl/l), reaching a 95% predictive positive value. Rast inhibition tests are useful to identify masked allergens in foods. Research developments will have impact on the development of new diagnostic tools: allergen mixes reinforcing a food extract by associated recombinant major allergens, multiple combination of recombinant allergens (chips) or tests with synthetic epitopes aimed a the prediction of recovery. Laboratory tests take place in the decision free for the diagnosis for the food allergy and the follow-up of the levels specific IgEs is a tool to assess outcome and contributes to predict recovery or persistent allergy. Up to now the

  15. Interference by pralidoxime (PAM) salts in clinical laboratory tests.

    Science.gov (United States)

    Nagase, Sumika; Kohguchi, Katsunori; Tohyama, Kaoru; Watanabe, Mikio; Iwatani, Yoshinori

    2013-02-01

    Drugs sometimes alter the results of clinical laboratory tests. We examined the effects of pralidoxime (PAM) salts, a medicine used to treat organophosphorus poisoning, on clinical laboratory test results for the first time. The effects of PAM salts on glucose (GLU) measurements were examined using a point-of-care testing (POCT) meter, four self-monitoring of blood glucose (SMBG) meters, and two biochemical autoanalyzers. The effects of PAM salts on other clinical tests were also evaluated. The addition of PAM iodide or potassium iodide, but not of PAM chloride or potassium chloride, to blood samples increased the GLU values measured by one POCT meter and 4 SMBG meters using the enzyme electrode (hydrogen peroxidase or oxygen electrode) method. On the other hand, PAM iodide or PAM chloride, but not KI or KCl, affected the values measured at 340 nm by an autoanalyzer using absorption spectrophotometry in 8 of 14 clinical laboratory tests. The absorption spectrum of PAM changed from 294 to 338 nm due to the reaction between PAM and the alkaline buffer, a component of the measuring reagents. PAM iodide increases the GLU values measured by the enzyme electrode method, and PAM salts affected the values measured at 340 nm by absorption spectrophotometry in many other clinical test items. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Proficiency testing schemes as a quality rating in industrial hygiene laboratories

    Directory of Open Access Journals (Sweden)

    Marek Dobecki

    2016-04-01

    Full Text Available This publication presents the principles of organization, implementation, assessment and exploitation of proficiency testing results in the work environmental laboratory based on basic requirements included in standard PN-EN ISO/IEC 17043 and ISO 13528. The basis for the proper functioning of the laboratory is to use and observe the basic requirements for the competence to carry out the tests and the guidelines on ensuring reliable and accurate results, specified e.g., according to the guidelines described in the standard PN-EN ISO/IEC 17043. The confirmation of the laboratory competence is the obtained accreditation. To obtain this certificate several conditions, including proficiency testing (PT should be met. The main aspects of this paper is to show the role of proficiency testing in the process of assuring a properly functioning quality system in the laboratory. The accreditation requirements, the types of proficiency testing schemes, methods of statistical analysis and interpretation of results are also discussed by the authors. Med Pr 2016;67(2:267–283

  17. Duplicate laboratory test reduction using a clinical decision support tool.

    Science.gov (United States)

    Procop, Gary W; Yerian, Lisa M; Wyllie, Robert; Harrison, A Marc; Kottke-Marchant, Kandice

    2014-05-01

    Duplicate laboratory tests that are unwarranted increase unnecessary phlebotomy, which contributes to iatrogenic anemia, decreased patient satisfaction, and increased health care costs. We employed a clinical decision support tool (CDST) to block unnecessary duplicate test orders during the computerized physician order entry (CPOE) process. We assessed laboratory cost savings after 2 years and searched for untoward patient events associated with this intervention. This CDST blocked 11,790 unnecessary duplicate test orders in these 2 years, which resulted in a cost savings of $183,586. There were no untoward effects reported associated with this intervention. The movement to CPOE affords real-time interaction between the laboratory and the physician through CDSTs that signal duplicate orders. These interactions save health care dollars and should also increase patient satisfaction and well-being.

  18. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  19. Mars Science Laboratory Rover System Thermal Test

    Science.gov (United States)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  20. Chemical Pathology Laboratory Tests in Pregnancy | Bolarin ...

    African Journals Online (AJOL)

    Thus, chemical pathology laboratory investigative test results during normal healthy pregnancy show significant differences from the normal reference intervals or ranges (i.e. non-pregnant woman's reference intervals or ranges) thereby causing misinterpretation as inappropriate or odd. This wrong interpretation of the ...

  1. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains.

    Science.gov (United States)

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-05-01

    Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. Published by the BMJ

  2. Application of flexible scope in large testing laboratories

    Directory of Open Access Journals (Sweden)

    Carina Di Candia

    2011-04-01

    Full Text Available According as the international definition of Flexible Scope, a laboratory must demonstrate face with the accreditation body that it has the knowledge, experience and competence to work within the full range of its flexible scope, as well as possessing suitable laboratory environments and equipment. The laboratory must also demonstrate that it has a management system in place that can control its proposed approach while continuing to comply with the requirements of ISO 17025:2005. In case of UKAS (Unites Kingdom Accreditation Service, prior to offering accreditation for flexible scope they must have a high degree of confidence that the staff are technically competent and that the management system controlling certain key processes as development, review, validation and authorization.LATU apply these requirements since 2004 as "Unified Tests". Until this date, LATU was doing the same type of tests in different materials departments using different equipment, personal, and testing quality control. In order to that were defined cross disciplinary groups to analyze this topic approaching in personal competence and quality control tests improvement, and resource's decrease. For example, LATU has the Unified Test Tensile Strength accredited by UKAS in: corrugated and solid fiberboard, paper board, linerboard, cork plugs, plastic bags, plastic sheeting, paper, woven fabrics, plastic woven bags and woven plastic. As a result of the Unified Tests was generated a general unified manage procedure with unified criteria's, responsibilities and actions. Was written a unique testing procedure not only with the actual flexible scope and the flexibilities limits but also the compliance requirements of ISO 17025 and the accreditations body methodology. We could decrease the amount of documentation to control. Was defined the methodology and implemented periodicaly internal inter comparisons between departments in order to valid the unified tests and has a unique

  3. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  4. Laboratory test for ice adhesion strength using commercial instrumentation.

    Science.gov (United States)

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  5. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    Science.gov (United States)

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  6. Utility of laboratory testing for the diagnosis of Hymenoptera venom allergy.

    Science.gov (United States)

    Vachová, Martina; Panzner, Petr; Malkusová, Ivana; Hanzlíková, Jana; Vlas, Tomáš

    2016-05-01

    A diagnosis of Hymenoptera venom allergy is based on clinical history and the results of skin tests and/or laboratory methods. To analyze the utility of available laboratory tests in diagnosing Hymenoptera venom allergy. Ninety-five patients with Hymenoptera venom allergy with a history of bee (35) or wasp (60) anaphylactic sting reaction and positive skin test with bee or wasp venom were included in this analysis. Specific immunoglobulin E (to bee venom extract, wasp venom extract, available recombinant molecules, and a basophil activation test with venom extracts were assessed in all the patients. Test sensitivity and specificity were calculated by using standard threshold values; then, receiver operating characteristic curve analysis was performed to compute optimal threshold values. Also, statistical analysis of the utility of different combinations of laboratory tests was performed. The optimal threshold values were revealed to be the following: 1.0 kIU/L for bee venom extract (sensitivity, 97.14%; specificity, 100%), 0.35 kIU/L for rApi m 1 (sensitivity, 68.57%; specificity, 100%), 1.22 kIU/L for wasp venom extract (sensitivity, 88.33%; specificity, 95.45%), 0.7 kIU/L for rVes v 5 (sensitivity, 86.67%; specificity, 95.45%), 1.0 kIU/L for rVes v 1 (sensitivity, 56.67%; specificity, 95.45%), 6.5% for basophil activation test with bee venom extract (sensitivity, 80%; specificity, 95.45%), and 4.5% for basophil activation test with wasp venom extract (sensitivity, 91.53%; specificity, 95.45%). The best test combinations were found to be the following: bee venom extract plus rApi m 1 (sensitivity, 97.14%; specificity, 95.45%) in bee and either wasp venom extract plus rVes v 5, or rVes v 5 plus rVes v 1 (both sensitivity, 98.33%; specificity, 95.45%) in patients with wasp venom allergy. Our analysis confirmed that currently used laboratory tests represent effective tools in diagnosing Hymenoptera venom allergy. Moreover, our probabilistic approach offered another

  7. Baking sunflower hulls within an aluminum envelope in a common laboratory oven yields charcoal.

    Science.gov (United States)

    Arnal, Pablo Maximiliano

    2015-01-01

    Charcoals have been widely used by scientist to research the removal of contaminants from water and air. One key feature of charcoal is that it keeps macropores from the parent material - though anisotropically contracted - and can even develop meso- and micropores. However, the controlled thermochemical conversion of biomass into charcoal at laboratory scale normally requires special setups which involve either vacuum or inert gas. Those setups may not be affordable in research groups or educational institutions where the research of charcoals would be highly welcome. In this work, I propose a simple and effective method to steer the thermochemical process that converts sunflower hulls (SFH) into charcoal with basic laboratory resources. The carbonization method: •Place SFH in an airtight aluminum envelope.•Thermally treat SFH within the envelope in a common laboratory oven.•Open the envelope to obtain the carbonized sunflower hulls.

  8. Educational ultrasound nondestructive testing laboratory.

    Science.gov (United States)

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  9. Package testing capabilities at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Taylor, J.M.

    1993-01-01

    The purpose of this paper is to describe the package testing capabilities at the Pacific Northwest Laboratory (PNL). In the past all of the package testing that was performed at PNL was done on prototype or mocked up radioactive material packaging. Presently, we are developing the capability to perform testing on non-radioactive material packaging. The testing on the non-radioactive material packaging will be done to satisfy the new performance oriented packaging requirements (DOT Docket HM-181, 1991). This paper describes the equipment used to perform the performance oriented packaging tests and also describes some testing capability for testing radioactive material packaging

  10. Relation between laboratory test results and histological hepatitis activity in individuals positive for hepatitis B surface antigen and antibodies to hepatitis B e antigen

    NARCIS (Netherlands)

    ter Borg, F.; ten Kate, F. J.; Cuypers, H. T.; Leentvaar-Kuijpers, A.; Oosting, J.; Wertheim-van Dillen, P. M.; Honkoop, P.; Rasch, M. C.; de Man, R. A.; van Hattum, J.; Chamuleau, R. A.; Reesink, H. W.; Jones, E. A.

    1998-01-01

    BACKGROUND: Hepatitis B surface antigen (HBsAg) and antibodies to hepatitis B e antigen (anti-HBe) commonly coexist, and laboratory tests are often requested to assess histological hepatitis activity. An optimum panel of tests has not been found and the usefulness of hepatitis B virus (HBV) DNA

  11. Directed energy deflection laboratory measurements of common space based targets

    Science.gov (United States)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  12. Laboratory test of an APS-based sun sensor prototype

    Science.gov (United States)

    Rufino, Giancarlo; Perrotta, Alessandro; Grassi, Michele

    2017-11-01

    This paper deals with design and prototype development of an Active Pixel Sensor - based miniature sun sensor and a laboratory facility for its indoor test and calibration. The miniature sun sensor is described and the laboratory test facility is presented in detail. The major focus of the paper is on tests and calibration of the sensor. Two different calibration functions have been adopted. They are based, respectively, on a geometrical model, which has required least-squares optimisation of system physical parameters estimates, and on neural networks. Calibration results are presented for the above solutions, showing that accuracy in the order of 0.01° has been achieved. Neural calibration functions have attained better performance thanks to their intrinsic auto-adaptive structure.

  13. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  14. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    Science.gov (United States)

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (Prate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  15. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld engines with the following steady-state duty cycle: G3 mode No. Engine speed a Torque(percent) b Weighting...

  16. A Comparative Study of Melanin Content and Skin Morphology for Three Commonly Used Laboratory Swine (Sus scrofa domestica)

    Science.gov (United States)

    2012-09-01

    Air Force Research Laboratory 711th Human Performance Wing Human Effectiveness Directorate Bioeffects Division Optical Radiation Bioeffects...Branch AFRL-RH-FS-TR-2013-0004 A Comparative Study of Melanin Content and Skin Morphology for Three Commonly Used Laboratory Swine (Sus scrofa...Jindra Human Effectiveness Directorate Directed Energy Bioeffects Division Optical Radiation Branch Robert W. Kornegay Rick Figueroa Human

  17. The laboratory test utilization management toolbox.

    Science.gov (United States)

    Baird, Geoffrey

    2014-01-01

    Efficiently managing laboratory test utilization requires both ensuring adequate utilization of needed tests in some patients and discouraging superfluous tests in other patients. After the difficult clinical decision is made to define the patients that do and do not need a test, a wealth of interventions are available to the clinician and laboratorian to help guide appropriate utilization. These interventions are collectively referred to here as the utilization management toolbox. Experience has shown that some tools in the toolbox are weak and other are strong, and that tools are most effective when many are used simultaneously. While the outcomes of utilization management studies are not always as concrete as may be desired, what data is available in the literature indicate that strong utilization management interventions are safe and effective measures to improve patient health and reduce waste in an era of increasing financial pressure.

  18. DTU PMU Laboratory Development - Testing and Validation

    OpenAIRE

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.; Nielsen, Arne Hejde; Østergaard, Jacob

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to foll...

  19. [Evaluation of common commercial systems for the identification of yeast isolates in microbiology laboratories: a multicenter study].

    Science.gov (United States)

    Karabıçak, Nilgün; Uludağ Altun, Hatice; Karatuna, Onur; Hazırolan, Gülşen; Aksu, Neriman; Adiloğlu, Ali; Akyar, Işın

    2015-04-01

    Accurate and rapid identification of yeast isolates have become important in recent years for not only antifungal susceptibility testing due to the species-specific clinical resistance breakpoints but also early initiation of appropriate antifungal therapy. In clinical microbiology laboratories species identification of yeasts is often performed with several commercial systems based on biochemical properties and rarely according to the physiological and morphological characteristics. The aim of this study was to compare the two common commercial systems, VITEK 2 YST ID Card (Vitek; bioMérieux, France) and API 20C AUX (API; bioMérieux, France) with conventional mycological methods. A total of 473 clinical yeast strains isolated from clinical specimens in different university and training/research hospitals and identified by Vitek system were included in the study. The isolates were re-identified with API and conventional methods including morphological identification in the Mycology Reference Laboratory of the Public Health Institute of Turkey. Candida dubliniensis MYA 583, Candida krusei ATCC 6258, Candida parapsilosis ATCC 22019, Candida albicans ATCC 10231 and Cryptococcus neoformans ATCC 32268 were used as quality control strains and those standard strains were studied consecutively 10 days with both of the methods. The results of identification by Vitek and API were compared with the results of conventional methods for those 473 yeast isolates [6 genus (Candida, Cryptococcus, Blastoshizomyces, Rhodotorula, Saccharomyces, Trichosporon), 17 species (5 common and 12 rarely isolated)]. The performances of the systems were better (Vitek: 95%; API: 96%) for the commonly detected species (C.albicans, C.parapsilosis, C.glabrata, C.tropicalis and C.krusei) than those for rarely detected species (Vitek: 78.4%; API: 71.6%) (p= 0.155). Misidentification or unidentification were mostly detected for C.parapsilosis (Vitek: 6/87; API: 7/87) and C.glabrata (Vitek: 9/104; API

  20. Model Testing - Bringing the Ocean into the Laboratory

    DEFF Research Database (Denmark)

    Aage, Christian

    2000-01-01

    Hydrodynamic model testing, the principle of bringing the ocean into the laboratory to study the behaviour of the ocean itself and the response of man-made structures in the ocean in reduced scale, has been known for centuries. Due to an insufficient understanding of the physics involved, however......, the early model tests often gave incomplete or directly misleading results.This keynote lecture deals with some of the possibilities and problems within the field of hydrodynamic and hydraulic model testing....

  1. Heat leak testing of a superconducting RHIC dipole magnet at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    DeLalio, J.T.; Brown, D.P.; Sondericker, J.H.

    1993-01-01

    Brookhaven National Laboratory is currently performing heat load tests on a superconducting dipole magnet. The magnet is a prototype of the 360, 8 cm bore, arc dipole magnets that will be used in the Relativistic Heavy Ion Collider (RMC). An accurate measurement of the heat load is needed to eliminate cumulative errors when determining the REUC cryogenic system load requirements. The test setup consists of a dipole positioned between two quadrupoles in a common vacuum tank and heat shield. Piping and instrumentation are arranged to facilitate measurement of the heat load on the primary 4.6 K magnet load and the secondary 55 K heat shield load. Initial results suggest that the primary heat load is well below design allowances. The secondary load was found to be higher than estimated, but remained close to the budgeted amount. Overall, the dipole performed to specifications

  2. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  3. Preliminary probe of quality indicators and quality specification in total testing process in 5753 laboratories in China.

    Science.gov (United States)

    Fei, Yang; Kang, Fengfeng; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Wang, Zhiguo; Chen, Wenxiang

    2016-08-01

    The aim of the study was to promote the establishment and implementation of quality indicators (QIs) in clinical laboratories, catch up with the state of art, and provide preliminary quality specifications for established QIs. Clinical laboratories from different provinces in China were included in this QIs survey in 2015. All participants were asked to collect data related to QIs and complete QIs questionnaires. Defect percentages and sigma values were calculated for each QI. The 25th percentile, median, and the 75th percentile of defect percentages and TATs were calculated as optimum, desirable and minimum quality specifications. While 25th, median, and 75th of sigma values were calculated as minimum, desirable and optimum quality specifications, respectively. Five thousand seven hundred and fifty-three clinical laboratories from 28 provinces in China participated in this survey. Median defect percentages of pre-examination QIs varied largely from 0.01% (incorrect sample container) to 0.57% (blood culture contamination) with sigma values varied from 4.0σ to 5.1σ. Median defect percentages of examination phase QIs were all really high. The most common problem in examination phase was test uncovered by inter-laboratory comparison (86.67%). Defect percentages of critical values notification and timely critical values notification were all 0.00% (6.0σ). While the median of defect percentages of incorrect laboratory reports was only 0.01% (5.4σ). Improvements are needed in all phases of total testing process (TTP) in laboratories in China, especially in examination phase. More attention should be paid when microbiology specimens are collected and results are reported. Quality specifications can provide directions for laboratories to make effort for.

  4. Wind Structural Testing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides office space for industry researchers, experimental laboratories, computer facilities for analytical work, and space for assembling components...

  5. Quality of HIV laboratory testing in Tanzania: a situation analysis ...

    African Journals Online (AJOL)

    December 2004 to February 2005 in 12 laboratories which were conveniently selected to represent all the zones of Tanzania. The questionnaires comprised of questions on laboratory particulars, internal and external quality control for HIV testing and quality control of reagents. Source and level of customer satisfaction of ...

  6. Sand characterization by combined centrifuge and laboratory tests

    OpenAIRE

    GAUDIN, C; SCHNAID, F; GARNIER, J

    2005-01-01

    The purpose of this paper is to evaluate new methods of interpretation of in situ tests in sand from correlations established from centrifuge and laboratory data. Emphasis is given to methods that are based on the combination of measurements from independent tests, such as the ratio of the elastic stiffness to ultimate strenght and the ratio of cone resistance and limit pressure. For that purpose, a series of centrifuge tests using a cone penetrometer and a cone pressuremeter was carried out ...

  7. Laboratory evaluation of the improved tube test detection limits for β ...

    African Journals Online (AJOL)

    Administrator

    1Antibiotic research laboratory, Dept. of Food Science, Swedish University of Agricultural Sciences, P.O. Box 7051, S- ... particular commonly utilised in lactating animals (Mandell and Perti ..... for other families of drugs such as sulfa drugs,.

  8. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  9. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  10. Laboratory Tests in the Development of WaveCat

    Directory of Open Access Journals (Sweden)

    James Allen

    2016-12-01

    Full Text Available WaveCat, a novel overtopping Wave Energy Converter, was tested with the aim of determining its performance under different sea states, establishing a starting point for optimisation of the device, numerical model validation and proof-of-concept for the control systems. The tests were carried out at a 1:30 scale in the Ocean Basin of the COAST Laboratory at University of Plymouth. A state-of-the-art control system was implemented, and overtopping rates and device motions were recorded alongside the wave field. It was observed that power generation is dependent on both the wave height and period, with smaller periods tending to produce greater overtopping rates, and therefore greater power generation, for the same wave height. Due to time constraints in the laboratory, only one configuration of draft/freeboard was tested; with this configuration, overtopping occurred under significant wave heights of 0.083 m or more, corresponding to 2.5 m or more in prototype values. These experimental results form the basis for future development and optimisation of WaveCat.

  11. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  12. Twenty Common Testing Mistakes for EFL Teachers to Avoid

    Science.gov (United States)

    Henning, Grant

    2012-01-01

    To some extent, good testing procedure, like good language use, can be achieved through avoidance of errors. Almost any language-instruction program requires the preparation and administration of tests, and it is only to the extent that certain common testing mistakes have been avoided that such tests can be said to be worthwhile selection,…

  13. Design and construction of the SSCL magnet test laboratory cryogenic systems

    International Nuclear Information System (INIS)

    Freeman, M.A.; Kobel, T.A.

    1992-01-01

    The intent of this document is to provide a brief summary of the execution, by Process Systems International, Inc. (PSI), of the Design and Construction of the SSCL Magnet Test Laboratory Cryogenic Systems. This $30 million project requires the expenditure of over 200,000 manhours and the procurement of $17 million in materials within a two year period. SSC magnets will be performance tested at the Magnet Test Laboratory (MTL) and the Accelerator System String Test (ASST) facility under conditions simulating the environment of the SSC main ring. The cryogenic system consists of test stands (five for MTL, one for ASST) and the associated equipment including cryogenic storage, purification, thermal conditioning, and helium refrigeration necessary to support the test program

  14. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    Science.gov (United States)

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  15. Interlaboratory test comparison among Environmental Radioactivity Laboratories using the ISO/IUPAC/AOAC Protocol

    International Nuclear Information System (INIS)

    Romero, L.; Ramos, L.; Salas, R.

    1998-01-01

    World-wide acceptance of results from radiochemical analyses requires reliable, traceable and comparable measurements to SI units, particularly when data sets generated by laboratories are to contribute to evaluation of data from environmental pollution research and monitoring programmes. The Spanish Nuclear Safety Council (CSN) organizes in collaboration with CIEMAT periodical interlaboratory test comparisons for environmental radioactivity laboratories aiming to provide them with the necessary means to asses the quality of their results. This paper presents data from the most recent exercise which, for the first time, was evaluated following the procedure recommended in the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories (1). The test sample was a Reference Material provided by the IAEA-AQCS, a lake sediment containing the following radionuclides: k-40, Ra-226, Ac-228, Cs-137, Sr-90, Pu-(239+240). The results of the proficiency test were computed for the 28 participating laboratories using the z-score approach, the evaluation of the exercises is presented in the paper. The use of a z-score classification has demonstrated to provide laboratories with a more objective means of assessing and demonstrating the reliability of the data they are producing. Analytical proficiency of the participating laboratories has been found to be satisfactory in 57 to 100 percent of cases. (1)- The International harmonized protocol for the proficiency testing of (chemical) analytical laboratories. Pure and Appl. Chem. Vol. 65, n 9, pp. 2123-2144, 1993 IUPAC. GB (Author) 3 refs

  16. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    Science.gov (United States)

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  17. Modernization of laboratories of test of electric measurer

    International Nuclear Information System (INIS)

    Cuervo, Luis Felipe

    1999-01-01

    The paper presents to the companies that possess test laboratories and calibration of electric measurer, an economic alternative for their modernization, using the repontentiation like an economic solution that it liberates resources to be used in other areas that they want it

  18. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  19. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate...

  20. Qualification of testing laboratories of Comision Nacional de Energia Atomica - CNEA

    International Nuclear Information System (INIS)

    Casa, Adriana; Palacios, Tulio; Peretti, Matilde; Pucci, Gladys; Resnizki, Sara

    1996-01-01

    Testing and calibration laboratories of the Argentine Atomic Energy Commission which made services for the nuclear and conventional industries must prove the reliability of their results. It is achieved implanting at the laboratories, a management quality system, to proof the capacity and technical aptitude, with the establish minimal requirements. When the requirement are fulfilled, the laboratory would be in conditions for a national level accreditation within the National System of Standards, Quality and Certification, recently created for our national government. The Laboratories Calibration Board of CNEA had made some assessments of a group of laboratories in order to determine their quality level. (author)

  1. [Unnecessary routine laboratory tests in patients referred for surgical services].

    Science.gov (United States)

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  2. The Livermore Free-Electron Laser Program Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Burns, M.J.; Kulke, B.; Deis, G.A.; Frye, R.W.; Kallman, J.S.; Ollis, C.W.; Tyler, G.C.; Van Maren, R.D.; Weiss, W.C.

    1987-01-01

    The Lawrence Livermore National Laboratory (LLNL) Free-Electron Laser Program Magnet Test Laboratory supports the ongoing development of the Induction Linac Free Electron Laser (IFEL) and uses magnetic field measurement systems that are useful in the testing of long periodic magnetic structures, electron-beam transport magnets, and spectrometer magnets. The major systems described include two computer-controlled, three-axis Hall probe-and-search coil transports with computer-controlled data acquisition; a unique, automated-search coil system used to detect very small inaccuracies in wiggler fields; a nuclear magnetic resonance (NMR)-based Hall probe-calibration facility; and a high-current DC ion source using heavy ions of variable momentum to model the transport of high-energy electrons. Additionally, a high-precision electron-beam-position monitor for use within long wigglers that has a positional resolution of less than 100 μm is under development in the laboratory and will be discussed briefly. Data transfer to LLNL's central computing facility and on-line graphics enable us to analyze large data sets quickly. 3 refs

  3. Recent package testing successes at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Ludwig, S.B.; Singley, P.T.; Michelhaugh, R.D.; Hawk, M.B.; Shappert, L.B.

    2004-01-01

    Oak Ridge National Laboratory (ORNL)'s history of testing of radioactive material packages dates back to the early 1960s, and includes the testing of hundreds of different packages of all shapes and sizes. This paper provides an overview of ORNL's new Packaging Research Facility (PRF) at the National Transportation Research Center (NTRC), and describes recent package testing successes conducted at the NTRC from September 2002 to September 2003

  4. Laboratory testing of LITCO glasses

    International Nuclear Information System (INIS)

    Ellison, A.; Wolf, S.; Buck, E.; Luo, J.S.; Dietz, N.; Bates, J.K.; Ebert, W.L.

    1995-01-01

    The purpose of this program is to measure, the intermediate and long-term durability of glasses developed by Lockheed Idaho Technology Co. (LITCO) for the immobilization of calcined radioactive wastes. The objective is to use accelerated corrosion tests as an aid in developing durable waste form compositions. This is a report of tests performed on two LITCO glass compositions, Formula 127 and Formula 532. The main avenue for release of radionuclides into the environment in a geologic repository is the reaction of a waste glass with ground water, which alters the glass and releases its components into solution. These stages in glass corrosion are analyzed by using accelerated laboratory tests in which the ratio of sample surface area to solution volume, SA/V, is varied. At low SA/V, the solution concentrations of glass corrosion products remain low and the reaction approaches the forward rate. At higher SA/V the solution approaches saturation levels for glass corrosion products. At very high SA/V the solution is rapidly saturated in glass corrosion products and secondary crystalline phases precipitate. Tests at very high SA/V provide information about the composition of the solution at saturation or, when no solution is recovered, the identities and the order of appearance of secondary crystalline phases. Tests were applied to Formula 127 and Formula 532 glasses to provide information about the interim and long-term stages in glass corrosion

  5. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    Science.gov (United States)

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  6. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  7. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    OpenAIRE

    V. A. Ivchin; K. Y. Samsonov

    2014-01-01

    The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter) flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  8. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Science.gov (United States)

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  9. Laboratory and field tests for radionuclide migration and high flow paths in clay

    International Nuclear Information System (INIS)

    Bourke, P.J.; Jefferies, N.L.; Lineham, T.R.; Nesirky, P.

    1991-01-01

    Two investigations have been undertaken in this programme. The principal investigation was at Culham Laboratory, England, where water flow within the Kimmeridge clay was measured. A subsidiary investigation at SCK/CEN was undertaken at the Underground Research Laboratory SCK/CEN Mol, Belgium, where an in situ measurement of solute transport by diffusion was attempted. The in situ migration experiment at the Underground Research Laboratory at SCK/CEN Mol, Belgium, was unsuccessful, due to problems with the engineering installation. These difficulties caused significant disturbance to the Boom clay which was to be tested. Nevertheless the laboratory test proved the feasibility of the experiment. The field measurements at Culham Laboratory, Oxfordshire, were completed with the flow testing of a very silty clay horizon in the Kimmeridge clay. This layer was proved to be laterally continuous after drilling three exploratory boreholes. The hydraulic conductivity of the layer was ≥ 10 -8 ms -1 and comparative tests in the clay showed the conductivity of the clay to be at least 50 times less. 12 figs

  10. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    Science.gov (United States)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  11. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  12. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories

    DEFF Research Database (Denmark)

    Koenen, K.; Uttenthal, Åse; Meindl-Böhmer, A.

    2007-01-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning....... It is essential that these plans are established during ‘peace-time’ and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance...

  13. Structural Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides a wide variety of testing equipment, fixtures and facilities to perform both unique aviation component testing as well as common types of materials testing...

  14. Crush Testing at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Feldman, Matthew R.

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

  15. Laboratory errors and patient safety.

    Science.gov (United States)

    Miligy, Dawlat A

    2015-01-01

    Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that

  16. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    Directory of Open Access Journals (Sweden)

    V. A. Ivchin

    2014-01-01

    Full Text Available The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  17. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  18. Feasibility of using overburden clays for sealing purposes and laboratory testing of the clays

    Energy Technology Data Exchange (ETDEWEB)

    Mann, J. (Vyzkumny Ustav pro Hnede Uhli, Most (Czechoslovakia))

    1992-03-01

    Studies properties of overburden clay from North Bohemian surface coal mines for use as sealants of industrial and household waste that will be dumped at Czechoslovak surface mine sites. Basic requirements of sealing layers are optimum compressibility and impermeability by suitable compacting. Laboratory soil mechanical tests of different clay samples were carried out using the Proctor standard tests (PCS) and the Norwegian Geonor A/S - m 45 instrument. Laboratory tests were used to select the best available clay types with optimum density and moisture content. Experimental results of laboratory tests are provided.

  19. A laboratory dispersant effectiveness test which reflects dispersant efficiency in the field

    International Nuclear Information System (INIS)

    Lunel, T.; Wood, P.

    1996-01-01

    Oil dispersion efficiencies of surfactants, from laboratory dispersion tests and field data were compared and calibrated. Data from an oil spill, where dispersants were used as a major part of the response, was analysed. The data was accumulated through the monitoring of the dispersant operation of the Sea Empress spill incident, in which Forties Blend oil was spilled at sea. This detailed data set was used to calibrate existing laboratory dispersant tests, and to devise a new International Dispersant Effectiveness Test. The objective was to create a comprehensive guide to decision making on whether and when to start a dispersant spraying operation. The dispersion efficiencies obtained from the laboratory dispersant tests were compared with field data. Flume tests produced the highest percentage of dispersed oil for all the dispersal tests. However, it was emphasised that the total percentage of oil dispersed should not be the only measure of dispersant effectiveness, since it does not distinguish between the contribution of natural and chemically enhanced dispersion. 9 refs., 1 tab., 9 figs

  20. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    International Nuclear Information System (INIS)

    Read, Rodney S.

    2011-07-01

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  1. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    Energy Technology Data Exchange (ETDEWEB)

    Read, Rodney S. (RSRead Consulting Inc. (Canada))

    2011-07-15

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  2. Laboratory testing of gneissic rocks in Olkiluoto borehole OL-KR24

    International Nuclear Information System (INIS)

    Eloranta, P.

    2006-10-01

    The stress-strain behaviour of anisotropic gneissic rocks from Olkiluoto, Finland, was studied for a total of 25 rock mechanics tests. Samples were selected from borehole OLKR24 at a depth level of 417-442 m. Tests included 15 uniaxial compression tests, 10 indirect tensile strength tests and 6 triaxial compression tests. Strain gauges were installed in five samples to evaluate the anisotropic properties, and acoustic emission sensors were installed in ten samples to estimate the stress damage levels. The specimen preparation and tests were carried out at the Laboratory of Rock Engineering, Helsinki University of Technology, Finland. Specimens were tested under laboratory-air-dry conditions and were photographed before and after the tests. The values obtained for the uniaxial compressive strength were in the range 56.5 - 165.9 MPa and for the indirect tensile strength 7.7 - 12.1 MPa. The anisotropic ratio of Young's modulus, E/E', was of the order of 1.1. (orig.)

  3. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  4. Can MOND type hypotheses be tested in a free fall laboratory environment?

    Science.gov (United States)

    Das, Saurya; Patitsas, S. N.

    2013-05-01

    The extremely small accelerations of objects required for the onset of modified Newtonian dynamics, or modified Newtonian dynamics (MOND), makes testing the hypothesis in conventional terrestrial laboratories virtually impossible. This is due to the large background acceleration of Earth, which is transmitted to the acceleration of test objects within an apparatus. We show, however, that it may be possible to test MOND-type hypotheses with experiments using a conventional apparatus capable of tracking very small accelerations of its components but performed in locally inertial frames such as artificial satellites and other freely falling laboratories. For example, experiments involving an optical interferometer or a torsion balance in these laboratories would show nonlinear dynamics and displacement amplitudes larger than expected. These experiments may also be able to test potential violations of the strong equivalence principle by MOND and to distinguish between its two possible interpretations (modified inertia and modified gravity).

  5. The changing face of hemostasis testing in modern laboratories: consolidation, automation, and beyond.

    Science.gov (United States)

    Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J

    2015-04-01

    The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Use of Proficiency Testing as a Tool to Improve Quality in Microbiology Laboratories.

    Science.gov (United States)

    Stang, Heather L; Anderson, Nancy L

    2013-09-15

    Proficiency testing (PT) is a valuable tool for assessing laboratory performance and verifying the accuracy and reliability of test results. Participation is required by the Clinical Laboratory Improvement Amendments (CLIA) of 1988 for each of the microbiology subspecialties (bacteriology, mycobacteriology, mycology, parasitology, and virology), and the regulations include specific PT requirements for each subspecialty. To determine the use and perceived value of PT beyond meeting CLIA requirements, the Centers for Disease Control and Prevention funded a cooperative agreement with the Association of Public Health Laboratories to convene a series of focus groups to query laboratory professionals responsible for PT. The seven focus groups were comprised of 60 laboratory professionals representing large and small clinical laboratories, microbiology subspecialties, and public health. While participants acknowledged the need to perform PT to meet regulatory requirements, many also cited benefits and challenges beyond regulatory compliance.

  7. DTU PMU Laboratory Development - Testing and Validation

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE...... standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to follow known patterns and provide confirmation about the test system to confirm the design and settings....... In a nutshell, having 2 PMUs that observe same signals provides validation of the operation and flags questionable results with more certainty. Moreover, the performance and accuracy of the DTU-PMU is tested acquiring good and precise results, when compared with a commercial phasor measurement device, PMU-1....

  8. Field and laboratory tests on acute toxicity of cadmium to freshwater crayfish

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    Environmental regulatory standards for cadmium (EPA 1980), like those for most pollutants, are based on acute, laboratory toxicity tests of single species. Such tests can be conducted rapidly and inexpensively in comparison to acute or chronic field studies, but their validity has often been questioned. Laboratory-based criteria are subject to two criticisms: (1) chemical and physical conditions differ greatly in degree and variability from laboratory to field, and (2) species are not isolated, but live in an ecosystem of interacting taxa and biofeedback. To investigate the validity of basing field toxicity standards on laboratory data, the authors subjected the freshwater crayfish Orconectes immunis for 96 h to various levels of cadmium in laboratory aquaria and experimental ponds. The study was designed to evaluate in part the first criticism of lab-based criteria. The studies were conducted concurrently with similar short-term experiments on the fathead minnow, Pimephales promelas, and coincided with studies of chronic cadmium stress on fathead minnows in experimental ponds.

  9. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  10. Technical performance of cementitious grouting materials for ONKALO. Laboratory tests 2006

    International Nuclear Information System (INIS)

    Raivio, P.; Hansen, J.

    2007-09-01

    During 2006 the development of high and low-pH cementitious grouts for fractures > 100 μm designed for the ONKALO rock was continued within the LPHTEK/IMAproject. The main focus in laboratory was to study high pH micro cement grouts. The low pH (≥ 11.0) of the cementitious grout material is required in deep repository as natural pH plume deriving from pure cement paste is very high and moves via ground water circulation in bedrock. This may be deleterious to the protective covers of nuclear waste. The objective to study high pH grouts in laboratory was to optimise their composition and to get preliminary test results. Low pH grouts based on Portland cement + micro silica were also studied further in laboratory to understand their behaviour more thoroughly in different conditions and due to quality changes in materials and to compare the laboratory results with the field results. Alternative fine-grained glass material was briefly studied to replace silica in low pH grout. Low and high pH rock bolt mortars were also developed and tested to get the preliminary test results. The results of the 2006 laboratory work are presented in this report. The high pH micro cement mix U1 with no silica, mix 5/5 with moderate silica and low pH mix P308B rich in silica show generally good properties at fresh and hardening stage at +12 deg C. Lower temperature gives weaker strength build-up with all the mixes and weakens especially the Marsh fluidity and penetration ability of the mixes 5/5 and P308B as bulk density rises a little at lower temperature. Cement quality variation and insufficient mixing may also weaken the properties of all mixes. Deformation of the hardened mixes was observed in laboratory tests. This may weaken their durability if cracks are formed in the grouts at later ages and need to be studied more thoroughly. (orig.)

  11. Point-Counterpoint: The FDA Has a Role in Regulation of Laboratory-Developed Tests.

    Science.gov (United States)

    Caliendo, Angela M; Hanson, Kimberly E

    2016-04-01

    Since the Food and Drug Administration (FDA) released its draft guidance on the regulation of laboratory-developed tests (LDTs) in October 2014, there has been a flurry of responses from commercial and hospital-based laboratory directors, clinicians, professional organizations, and diagnostic companies. The FDA defines an LDT as an "in vitrodiagnostic device that is intended for clinical use and is designed, manufactured, and used within a single laboratory." The draft guidance outlines a risk-based approach, with oversight of high-risk and moderate-risk tests being phased in over 9 years. High-risk tests would be regulated first and require premarket approval. Subsequently, moderate-risk tests would require a 510(k) premarket submission to the FDA and low-risk tests would need only to be registered. Oversight discretion would be exercised for LDTs focused on rare diseases (defined as fewer than 4,000 tests, not cases, per year nationally) and unmet clinical needs (defined as those tests for which there is no alternative FDA-cleared or -approved test). There was an open comment period followed by a public hearing in early January of 2015, and we are currently awaiting the final decision regarding the regulation of LDTs. Given that LDTs have been developed by many laboratories and are essential for the diagnosis and monitoring of an array of infectious diseases, changes in their regulation will have far-reaching implications for clinical microbiology laboratories. In this Point-Counterpoint, Angela Caliendo discusses the potential benefits of the FDA guidance for LDTs whereas Kim Hanson discusses the concerns associated with implementing the guidance and why these regulations may not improve clinical care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  13. Clinical laboratory billing: superfluous requirements without justification?

    Science.gov (United States)

    Stadler, Stephen

    2004-01-01

    Congress occasionally passes new laws that affect how clinical laboratories handle test orders from physicians and, subsequently, process the billing for tests. Once a bill is signed into law, it is forwarded to administrative agencies, which draft regulations and administrative procedures, under which the intentions of Congress are carried out. In the case of laboratory test ordering and billing, the Centers for Medicare and Medicaid Services (CMS) has the greatest influence over how these regulations and procedures are defined. Unfortunately, in many cases, billing rules have been promulgated in ways that create the need for hospitals and commercial laboratories to expend huge sums of money to bill within the confines of the administrative rules; cause clinical laboratories to suffer from omissions and mistakes of other parties who are part of the patient care process but are not accountable for the billing information they provide to laboratories; and, frankly, in some respects, simply defy common sense.

  14. Laboratory accreditation in developing economies

    International Nuclear Information System (INIS)

    Loesener, O.

    2004-01-01

    Full text: Accreditation of laboratories has been practiced for well over one hundred years with the primary objective of seeking a formal recognition for the competence of a laboratory to perform specified tests or measurements. While first accreditation schemes intended initially to serve only the immediate needs of the body making the evaluation with the purpose of minimizing testing and inspection to be conducted by laboratories, third-party accreditation enables a laboratory to demonstrate its capability as well as availability of all necessary resources to undertake particular tests correctly and that is managed in such a way that it is likely to do this consistently, taking into consideration standards developed by national and international standards-setting bodies. The international standard ISO/IEC 17025 and laboratory accreditation are concerned with competence and quality management of laboratories only, thus requiring a single common set of criteria applicable to them. Quality assurance is therefore fully relevant to laboratories in general and analytical laboratories in particular; it should not be confused with the certification approach according to ISO/IEC 9000 family of standards, that is concerned with quality management applicable to any organization as a whole. The role of laboratory accreditation can be manifold, but in all cases the recipient of the test report needs to have confidence that the data in it is reliable, particularly if the test data is important in a decision-making process. As such, it offers a comprehensive way to ensure: - the availability of managerial and technical staff with the authority and resources needed; - the effectiveness of equipment management, traceability of measurement and safety procedures; - the performance of tests, taking into consideration laboratory accommodation and facilities as well as laboratory practices. The presentation will include also some practical aspects of quality management system

  15. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  16. Impact of providing fee data on laboratory test ordering: a controlled clinical trial.

    Science.gov (United States)

    Feldman, Leonard S; Shihab, Hasan M; Thiemann, David; Yeh, Hsin-Chieh; Ardolino, Margaret; Mandell, Steven; Brotman, Daniel J

    2013-05-27

    Inpatient care providers often order laboratory tests without any appreciation for the costs of the tests. To determine whether we could decrease the number of laboratory tests ordered by presenting providers with test fees at the time of order entry in a tertiary care hospital, without adding extra steps to the ordering process. Controlled clinical trial. Tertiary care hospital. All providers, including physicians and nonphysicians, who ordered laboratory tests through the computerized provider order entry system at The Johns Hopkins Hospital. We randomly assigned 61 diagnostic laboratory tests to an "active" arm (fee displayed) or to a control arm (fee not displayed). During a 6-month baseline period (November 10, 2008, through May 9, 2009), we did not display any fee data. During a 6-month intervention period 1 year later (November 10, 2009, through May 9, 2010), we displayed fees, based on the Medicare allowable fee, for active tests only. We examined changes in the total number of orders placed, the frequency of ordered tests (per patient-day), and total charges associated with the orders according to the time period (baseline vs intervention period) and by study group (active test vs control). For the active arm tests, rates of test ordering were reduced from 3.72 tests per patient-day in the baseline period to 3.40 tests per patient-day in the intervention period (8.59% decrease; 95% CI, -8.99% to -8.19%). For control arm tests, ordering increased from 1.15 to 1.22 tests per patient-day from the baseline period to the intervention period (5.64% increase; 95% CI, 4.90% to 6.39%) (P fee data to providers at the time of order entry resulted in a modest decrease in test ordering. Adoption of this intervention may reduce the number of inappropriately ordered diagnostic tests.

  17. The development of Metacognition test in genetics laboratory for undergraduate students

    Science.gov (United States)

    A-nongwech, Nattapong; Pruekpramool, Chaninan

    2018-01-01

    The purpose of this research was to develop a Metacognition test in a Genetics Laboratory for undergraduate students. The participants were 30 undergraduate students of a Rajabhat university in Rattanakosin group in the second semester of the 2016 academic year using purposive sampling. The research instrument consisted of 1) Metacognition test and 2) a Metacognition test evaluation form for experts focused on three main points which were an accurate evaluation form of content, a consistency between Metacognition experiences and questions and the appropriateness of the test. The quality of the test was analyzed by using the Index of Consistency (IOC), discrimination and reliability. The results of developing Metacognition test were summarized as 1) The result of developing Metacognition test in a Genetics Laboratory for undergraduate students found that the Metacognition test contained 56 items of open - ended questions. The test composed of 1) four scientific situations, 2) fourteen items of open - ended questions in each scientific situation for evaluating components of Metacognition. The components of Metacognition consisted of Metacognitive knowledge, which were divided into person knowledge, task knowledge and strategy knowledge and Metacognitive experience, which were divided into planning, monitoring and evaluating, and 3) fourteen items of scoring criteria divided into four scales. 2) The results of the item analysis of Metacognition in Genetics Laboratory for undergraduate students found that Index of Consistency between Metacognitive experiences and questions were in the range between 0.75 - 1.00. An accuracy of content equaled 1.00. The appropriateness of the test equaled 1.00 in all situations and items. The discrimination of the test was in the range between 0.00 - 0.73. Furthermore, the reliability of the test equaled 0.97.

  18. Laboratory shake flask batch tests can predict field biodegradation of aniline in the Rhine

    DEFF Research Database (Denmark)

    Toräng, Lars; Reuschenbach, P.; Müller, B.

    2001-01-01

    .7 degreesC, respectively. This field rate estimate was compared with results from 38 laboratory shake flask batch tests with Rhine water which averaged 1.5 day(-1) at 15 degreesC and 2.0 day(-1) at 20 degreesC. These results indicate that laboratory shake flask batch tests with low concentrations of test...

  19. PAPI based federation as a test-bed for a common security infrastructure in EFDA sites

    International Nuclear Information System (INIS)

    Castro, R.; Vega, J.; Portas, A.; Lopez, D.R.; Balme, S.; Theis, J.M.; Lebourg, P.; Fernandes, H.; Neto, A.; Duarte, A.; Oliveira, F.; Reis, F.; Purahoo, K.; Thomsen, K.; Schiller, W.; Kadlecsik, J.

    2008-01-01

    Federated authentication and authorization systems provide several advantages to collaborative environments, for example, easy authentication integration, simpler user management, easier security policy implementation and quicker implementation of access control elements for new type of resources. A federation integrates different aspects that have to be coordinated by all the organizations involved. The most relevant are: definition of common schemas and attributes, definition of common policies and procedures, management of keys and certificates, management of common repositories and implementation of a home location service. A federation enabling collaboration of European sites has been put into operation. Four laboratories have been integrated and two more organizations (EFDA and KFKI/HAS) are finishing their integration. The federation infrastructure is based on Point of Access to Providers of Information (PAPI), a distributed authentication and authorization system. PAPI technology gives some important features, such as, single sign on for accessing to different resources, mobility for users, and compatibility with open and standard technologies: Java, JNLP protocol, XML-RPC and web technologies among others. In this article, the test-bed of EFDA federation is presented. Some examples of resources, securely shared inside the federation, are shown. Specific issues and experience gained in deploying federated collaboration systems will be addressed as well

  20. PAPI based federation as a test-bed for a common security infrastructure in EFDA sites

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)], E-mail: rodrigo.castro@ciemat.es; Vega, J.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Lopez, D.R. [Departamento RedIRIS, Entidad publica empresarial Red.es, Madrid (Spain); Balme, S.; Theis, J.M.; Lebourg, P. [Association EURATOM-CEA, CEA/DSM/Departement de Recherches sur la Fusion Controlee DRFC, CEA-Cadarache (France); Fernandes, H.; Neto, A.; Duarte, A.; Oliveira, F.; Reis, F. [Centro de Fusao Nuclear, Associacao EURATOM/IST, Lisboa (Portugal); Purahoo, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Thomsen, K.; Schiller, W. [EFDA Close Support Unit Garching, Max Planck Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany); Kadlecsik, J. [KFKI R.I. for Particle and Nuclear Physics of the Hungarian Academy of Sciences, and the Association EURATOM/HAS, Budapest (Hungary)

    2008-04-15

    Federated authentication and authorization systems provide several advantages to collaborative environments, for example, easy authentication integration, simpler user management, easier security policy implementation and quicker implementation of access control elements for new type of resources. A federation integrates different aspects that have to be coordinated by all the organizations involved. The most relevant are: definition of common schemas and attributes, definition of common policies and procedures, management of keys and certificates, management of common repositories and implementation of a home location service. A federation enabling collaboration of European sites has been put into operation. Four laboratories have been integrated and two more organizations (EFDA and KFKI/HAS) are finishing their integration. The federation infrastructure is based on Point of Access to Providers of Information (PAPI), a distributed authentication and authorization system. PAPI technology gives some important features, such as, single sign on for accessing to different resources, mobility for users, and compatibility with open and standard technologies: Java, JNLP protocol, XML-RPC and web technologies among others. In this article, the test-bed of EFDA federation is presented. Some examples of resources, securely shared inside the federation, are shown. Specific issues and experience gained in deploying federated collaboration systems will be addressed as well.

  1. Single and Combined Diagnostic Value of Clinical Features and Laboratory Tests in Acute Appendicitis

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Go, Peter M. N. Y. H.; Bouma, Wim H.; Donkervoort, Sandra C.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2009-01-01

    Objectives: The objective was to evaluate the diagnostic accuracy of clinical features and laboratory test results in detecting acute appendicitis. Methods: Clinical features and laboratory test results were prospectively recorded in a consecutive series of 1,101 patients presenting with abdominal

  2. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    Science.gov (United States)

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  3. A possible laboratory test for the axions

    International Nuclear Information System (INIS)

    Ramachandran, G.; Vinay Deepak, H.S.; Thomas, Sujith; Raghunath, C.; Cowsik, R.

    2011-01-01

    The axion is a hypothetical light boson with spin zero which was introduced theoretically more than 3 decades ago, following the Peccei-Quinn solution to the strong CP problem. The axion is one amongst the candidates for dark matter along with neutrinos, WIMPS, SIMPS, CHAMPS and Super heavy particles which could possibly be detected by neutrino facilities like IceCube. The purpose of the present contribution is to suggest a laboratory test for the existence of axions

  4. Canadian Public Health Laboratory Network Laboratory Guidelines for the Use of Direct Tests to Detect Syphilis in Canada

    Directory of Open Access Journals (Sweden)

    Raymond SW Tsang

    2015-01-01

    Full Text Available Treponema pallidum subsp. pallidum and/or its nucleic acid can be detected by various methods such as microscopy, rabbit infectivity test or polymerase chain reaction (PCR tests. The rabbit infectivity test for T. pallidum, although very sensitive, has been discontinued from most laboratories due to ethical issues related to the need for animal inoculation with live T. pallidum, the technically demanding procedure and long turnaround time for results, thus making it impractical for routine diagnostic use. Dark-field and phase-contrast microscopy are still useful at clinic- or hospital-based laboratories for near-bedside detection of T. pallidum in genital, skin or mucous lesions although their availability is decreasing. The lack of reliable and specific anti-T. pallidum antibodies and its inferior sensitivity to PCR may explain why the direct fluorescent antibody test for T. pallidum is not widely available for clinical use. Immunohistochemical staining for T. pallidum also depends on the availability of specific antibodies, and the method is only applicable for histopathological examination of biopsy and autopsy specimens necessitating an invasive specimen collection approach. With recent advances in molecular diagnostics, PCR is considered to be the most reliable, versatile and practical for laboratories to implement. In addition to being an objective and sensitive test for direct detection of Treponema pallidum subsp. pallidum DNA in skin and mucous membrane lesions, the resulting PCR amplicons from selected gene targets can be further characterized for antimicrobial (macrolide susceptibility testing, strain typing and identification of T. pallidum subspecies.

  5. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Science.gov (United States)

    2010-01-01

    ... request approval to conduct one or more types of scrapie test or genotype test on one or more types of... type of test and for each type of tissue for which they request approval. (c) The Administrator may... the laboratory and shall give the director an opportunity to respond. If there are conflicts as to any...

  6. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT... on live or dead animals, and will base the approval or disapproval of a test on the evaluation by...

  7. Continuous Analytical Performances Monitoring at the On-Site Laboratory through Proficiency, Inter-Laboratory Testing and Inter-Comparison Analytical Methods

    International Nuclear Information System (INIS)

    Duhamel, G.; Decaillon, J.-G.; Dashdondog, S.; Kim, C.-K.; Toervenyi, A.; Hara, S.; Kato, S.; Kawaguchi, T.; Matsuzawa, K.

    2015-01-01

    Since 2008, as one measure to strengthen its quality management system, the On-Site Laboratory for nuclear safeguards at the Rokkasho Reprocessing Plant, has increased its participation in domestic and international proficiency and inter-laboratory testing for the purpose of determining analytical method accuracy, precision and robustness but also to support method development and improvement. This paper provides a description of the testing and its scheduling. It presents the way the testing was optimized to cover most of the analytical methods at the OSL. The paper presents the methodology used for the evaluation of the obtained results based on Analysis of variance (ANOVA). Results are discussed with respect to random, systematic and long term systematic error. (author)

  8. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities

    Science.gov (United States)

    Hebert, Phillip W., Sr.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Hughes, Mark S.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition systems (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis development and deployment.

  9. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  10. Radioactivity decontamination of materials commonly used as surfaces in general-purpose radioisotope laboratories.

    Science.gov (United States)

    Leonardi, Natalia M; Tesán, Fiorella C; Zubillaga, Marcela B; Salgueiro, María J

    2014-12-01

    In accord with as-low-as-reasonably-achievable and good-manufacturing-practice concepts, the present study evaluated the efficiency of radioactivity decontamination of materials commonly used in laboratory surfaces and whether solvent spills on these materials affect the findings. Four materials were evaluated: stainless steel, a surface comprising one-third acrylic resin and two-thirds natural minerals, an epoxy cover, and vinyl-based multipurpose flooring. Radioactive material was eluted from a (99)Mo/(99m)Tc generator, and samples of the surfaces were control-contaminated with 37 MBq (100 μL) of this eluate. The same procedure was repeated with samples of surfaces previously treated with 4 solvents: methanol, methyl ethyl ketone, acetone, and ethanol. The wet radioactive contamination was allowed to dry and then was removed with cotton swabs soaked in soapy water. The effectiveness of decontamination was defined as the percentage of activity removed per cotton swab, and the efficacy of decontamination was defined as the total percentage of activity removed, which was obtained by summing the percentages of activity in all the swabs required to complete the decontamination. Decontamination using our protocol was most effective and most efficacious for stainless steel and multipurpose flooring. Moreover, treatment with common organic solvents seemed not to affect the decontamination of these surfaces. Decontamination of the other two materials was less efficient and was interfered with by the organic solvents; there was also great variability in the overall results obtained for these other two materials. In expanding our laboratory, it is possible for us to select those surface materials on which our decontamination protocol works best. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Alternative method for intramuscular fat analysis using common laboratory equipment.

    Science.gov (United States)

    Segura, J; Calvo, L; Óvilo, C; González-Bulnes, A; Olivares, A; Cambero, M I; López-Bote, C J

    2015-05-01

    A procedure to quantify intramuscular fat was developed using common inexpensive laboratory equipment. Three homogenization methods of lyophilized muscle samples (Ball-mill, Grinder and Mortar) and two extraction methods (Ball-mill or Vortex) were used in turkey meat and pork. Two-hundred mg of lyophilized and homogenized samples were accurately weighed and mixed with 1.5 mL of dichloromethane-methanol (8:2) and shaken either in a Mixer Mill (MM400, Retsch Technology) or in a Vortex. The final mixture was separated by centrifugation. Solvent was evaporated under a nitrogen stream and lipid content was gravimetrically determined. Besides, it was checked that the fatty acid profile was not altered by the protocol used. Moreover, the analysis of 4 replicas from the same sample showed different variation coefficients (16-29%) for the new procedures proposed over a wide range of IMF content. The combination of Grinder and Vortex methodologies can be proposed as a simple and inexpensive alternative to previous ones. Copyright © 2015. Published by Elsevier Ltd.

  12. Potential over request in anemia laboratory tests in primary care in Spain.

    Science.gov (United States)

    Salinas, María; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-07-01

    The aim was to study the inter-practice variability in anemia laboratory tests requested by general practitioners in Spain, to evaluate for a potential requesting inappropriateness. Laboratories from diverse Spanish regions filled out the number of cell blood count, ferritin, folate, iron, transferrin, and vitamin B12 requested by general practitioners during 2012. The number of test requests per 1000 inhabitants and ratios of related tests requests were calculated. The results obtained in hospitals from different areas (urban, rural, or urban-rural), type of management (public or private), and geographic regions were compared. There was a high variability in the number of test requests and ratios of related tests. Cell blood count was over requested in rural areas and in hospitals with private management. Andalucía was the community with the lowest number of iron requests and the lowest folate/vitamin B12 indicator value. Iron and transferrin seemed over requested in some areas; as were folate and ferritin when compared to vitamin B12 and cell blood count, respectively. The differences observed between areas indicate that other factors besides clinical reasons could be behind that variability and emphasize the need to accomplish interventions to improve the appropriate use of anemia laboratory tests.

  13. Kidney function tests

    Science.gov (United States)

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  14. SENSORY AND CONSUMER TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — These laboratories conduct a wide range of studies to characterize the sensory properties of and consumer responses to foods, beverages, and other consumer products....

  15. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    Science.gov (United States)

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  16. 75 FR 39954 - Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location

    Science.gov (United States)

    2010-07-13

    ...] Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location AGENCY: Food and Drug... location for the upcoming public meeting entitled ``Oversight of Laboratory Developed Tests.'' A new... the public meeting, FDA is announcing in this notice a new location for the public meeting. II. New...

  17. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  18. Laboratory tests in support of the MSRE reactive gas removal system

    International Nuclear Information System (INIS)

    Rudolph, J.C.; Del Cul, G.D.; Caja, J.; Toth, L.M.; Williams, D.F.; Thomas, K.S.; Clark, D.E.

    1997-07-01

    The Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has been shut down since December 1969, at which time the molten salt mixture of LiF-BeF 2 -ZrF 4 - 233 UF 4 (64.5-30.3-5.0-0.13 mol%) was transferred to fuel salt drain tanks for storage. In the late 1980s, increased radiation in one of the gas lines from the drain tank was attributed to 233 UF 6 . In 1994 two gas samples were withdraw (from a gas line in the Vent House connecting to the drain tanks) and analyzed. Surprisingly, 350 mm Hg of F 2 , 70 mm Hg of UF 6 , and smaller amounts of other gases were found in both of the samples. To remote this gas from above the drain tanks and all of the associated piping, the reactive gas removal system (RGRS) was designed. This report details the laboratory testing of the RGRS, using natural uranium, prior to its implementation at the MSRE facility. The testing was performed to ensure that the equipment functioned properly and was sufficient to perform the task while minimizing exposure to personnel. In addition, the laboratory work provided the research and development effort necessary to maximize the performance of the system. Throughout this work technicians and staff who were to be involved in RGRS operation at the MSRE site worked directly with the research staff in completing the laboratory testing phase. Consequently, at the end of the laboratory work, the personnel who were to be involved in the actual operations had acquired all of the training and experience necessary to continue with the process of reactive gas removal

  19. Automation software for a materials testing laboratory

    Science.gov (United States)

    Mcgaw, Michael A.; Bonacuse, Peter J.

    1990-01-01

    The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.

  20. Identification of common allergens for united airway disease by skin prick test

    Directory of Open Access Journals (Sweden)

    Vikas Deep Mishra

    2016-01-01

    Full Text Available Objective: Identification of common allergens by skin prick test in patients of united airway disease. Materials and Methods: Skin prick test was performed in 60 patients of United Airway Disease to identify the common allergens. A total of 62 allergens consisting of 36 types of pollen, 5 fungi, 4 insects, 8 type of dusts, 4 dander, 3 fabrics, Dust mite and Parthenium leaves were tested. Result: Most common allergens were Dust mite (60% followed by Parthenium leaves (45%, insects (18.75%, pollen (14.81%, dust allergens (8.51%, fabrics (8.33%, fungi (5.66%, dander (5%. Most common insect allergens were cockroach (female (30%, cockroach (male (23.33%. Common pollens were Ricinus communis (28.33%, Amaranthus spinosus (28.33%, Parthenium hysterophorus (26.66%, Eucalyptus tereticornis (26.66% and Cynodon dactylon (25%. Common dust allergens were house dust (21.66%, paper dust (11.66% and cotton mill dust (10%. Among fabrics kapok cotton (13.33% showed maximum positivity. Among fungi Aspergillus fumigatus (10% followed by A. niger (6.66% were most common. In animal dander group common ones were cat dander followed by dog dander. Conclusion: In conclusion it can be said that the knowledge drawn by above study will help to treat patients by immunotherapy or avoidance strategy.

  1. Reduction in Unnecessary Clinical Laboratory Testing Through Utilization Management at a US Government Veterans Affairs Hospital.

    Science.gov (United States)

    Konger, Raymond L; Ndekwe, Paul; Jones, Genea; Schmidt, Ronald P; Trey, Marty; Baty, Eric J; Wilhite, Denise; Munshi, Imtiaz A; Sutter, Bradley M; Rao, Maddamsetti; Bashir, Chowdry M

    2016-03-01

    To implement an electronic laboratory utilization management system (laboratory expert system [LES]) to provide safe and effective reductions in unnecessary clinical laboratory testing. The LES is a set of frequency filter subroutines within the Veterans Affairs hospital and laboratory information system that was formulated by an interdisciplinary medical team. Since implementing the LES, total test volume has decreased by a mean of 11.18% per year compared with our pre-LES test volume. This change was not attributable to fluctuations in outpatient visits or inpatient days of care. Laboratory cost savings were estimated at $151,184 and $163,751 for 2012 and 2013, respectively. A significant portion of these cost savings was attributable to reductions in high-volume, large panel testing. No adverse effects on patient care were reported, and mean length of stay for patients remained unchanged. Electronic laboratory utilization systems can effectively reduce unnecessary laboratory testing without compromising patient care. Published by Oxford University Press on behalf of the American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the US.

  2. Use of Proficiency Testing as a Tool to Improve Quality in Microbiology Laboratories

    OpenAIRE

    Stang, Heather L.; Anderson, Nancy L.

    2013-01-01

    Proficiency testing (PT) is a valuable tool for assessing laboratory performance and verifying the accuracy and reliability of test results. Participation is required by the Clinical Laboratory Improvement Amendments (CLIA) of 1988 for each of the microbiology subspecialties (bacteriology, mycobacteriology, mycology, parasitology, and virology), and the regulations include specific PT requirements for each subspecialty. To determine the use and perceived value of PT beyond meeting CLIA requir...

  3. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  4. Presentation of laboratory test results in patient portals: influence of interface design on risk interpretation and visual search behaviour.

    Science.gov (United States)

    Fraccaro, Paolo; Vigo, Markel; Balatsoukas, Panagiotis; van der Veer, Sabine N; Hassan, Lamiece; Williams, Richard; Wood, Grahame; Sinha, Smeeta; Buchan, Iain; Peek, Niels

    2018-02-12

    Patient portals are considered valuable instruments for self-management of long term conditions, however, there are concerns over how patients might interpret and act on the clinical information they access. We hypothesized that visual cues improve patients' abilities to correctly interpret laboratory test results presented through patient portals. We also assessed, by applying eye-tracking methods, the relationship between risk interpretation and visual search behaviour. We conducted a controlled study with 20 kidney transplant patients. Participants viewed three different graphical presentations in each of low, medium, and high risk clinical scenarios composed of results for 28 laboratory tests. After viewing each clinical scenario, patients were asked how they would have acted in real life if the results were their own, as a proxy of their risk interpretation. They could choose between: 1) Calling their doctor immediately (high interpreted risk); 2) Trying to arrange an appointment within the next 4 weeks (medium interpreted risk); 3) Waiting for the next appointment in 3 months (low interpreted risk). For each presentation, we assessed accuracy of patients' risk interpretation, and employed eye tracking to assess and compare visual search behaviour. Misinterpretation of risk was common, with 65% of participants underestimating the need for action across all presentations at least once. Participants found it particularly difficult to interpret medium risk clinical scenarios. Participants who consistently understood when action was needed showed a higher visual search efficiency, suggesting a better strategy to cope with information overload that helped them to focus on the laboratory tests most relevant to their condition. This study confirms patients' difficulties in interpreting laboratories test results, with many patients underestimating the need for action, even when abnormal values were highlighted or grouped together. Our findings raise patient safety

  5. Mars Science Laboratory Flight Software Internal Testing

    Science.gov (United States)

    Jones, Justin D.; Lam, Danny

    2011-01-01

    The Mars Science Laboratory (MSL) team is sending the rover, Curiosity, to Mars, and therefore is physically and technically complex. During my stay, I have assisted the MSL Flight Software (FSW) team in implementing functional test scripts to ensure that the FSW performs to the best of its abilities. There are a large number of FSW requirements that have been written up for implementation; however I have only been assigned a few sections of these requirements. There are many stages within testing; one of the early stages is FSW Internal Testing (FIT). The FIT team can accomplish this with simulation software and the MSL Test Automation Kit (MTAK). MTAK has the ability to integrate with the Software Simulation Equipment (SSE) and the Mission Processing and Control System (MPCS) software which makes it a powerful tool within the MSL FSW development process. The MSL team must ensure that the rover accomplishes all stages of the mission successfully. Due to the natural complexity of this project there is a strong emphasis on testing, as failure is not an option. The entire mission could be jeopardized if something is overlooked.

  6. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  7. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Nikolac, Nora; Simundic, Ana-Maria; Kackov, Sanja; Serdar, Tihana; Dorotic, Adrijana; Fumic, Ksenija; Gudasic-Vrdoljak, Jelena; Klenkar, Kornelija; Sambunjak, Jadranka; Vidranski, Valentina

    2015-10-23

    The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert; Schenkman, Ben; Klapp, Dave; Linton, Ed; Hurtado, Hector; Roy, Jean; Lewis, Nancy Jo; Stevens, John; Volkommer, Harry

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.

  9. Laboratory competence evaluation through proficiency testing - mycotoxins in food

    Directory of Open Access Journals (Sweden)

    Torović Ljilja D.

    2017-01-01

    Full Text Available Laboratory for analysis of mycotoxins in food at the Institute of Public Health of Vojvodina (Novi Sad, Serbia participated in 15 proficiency testing schemes in period 2012-2016, comprising 22 determinations of regulated mycotoxins: aflatoxins B1, B2, G1, G2 and M1, ochratoxin A, deoxynivalenone, zearalenone, fumonisins and patulin, in different food commodities: wheat, corn, barley, breakfast cereals, infant food, milk, wine and fruit juice. Analyses were carried out by high performance liquid chromatography with ultraviolet (patulin, deoxynivalenol or fluorescence detection (aflatoxin M1, ochratoxin A, zearalenone using o-phthalaldehyde precolumn derivatization (fumonisins or UV postcolumn derivatization (aflatoxins B1, B2, G1, G2, following clean-up on immunoaffinity columns with specific antibodies, except in case of patulin when solvent extraction and solid-phase C-18 clean-up were used. Laboratory performance assessed in terms of z scores showed all satisfactory results. In depth evaluation revealed following distribution of z scores (absolute values: 59.1% up to 0.5, 36.4% between 0.5 and 1.0, and 4.5% above 1.0. Analysis of trends performed for multiple determinations of individual mycotoxins showed several changes of z score to better or worse rank. Overall assessment of the performance in proficiency testing demonstrated laboratory competence for analysis of mycotoxins in food.

  10. Laboratory rock mechanics testing manual. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    Shuri, F S; Cooper, J D; Hamill, M L

    1981-10-01

    Standardized laboratory rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state-of-the-art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements.

  11. Geographically distributed hybrid testing & collaboration between geotechnical centrifuge and structures laboratories

    Science.gov (United States)

    Ojaghi, Mobin; Martínez, Ignacio Lamata; Dietz, Matt S.; Williams, Martin S.; Blakeborough, Anthony; Crewe, Adam J.; Taylor, Colin A.; Madabhushi, S. P. Gopal; Haigh, Stuart K.

    2018-01-01

    Distributed Hybrid Testing (DHT) is an experimental technique designed to capitalise on advances in modern networking infrastructure to overcome traditional laboratory capacity limitations. By coupling the heterogeneous test apparatus and computational resources of geographically distributed laboratories, DHT provides the means to take on complex, multi-disciplinary challenges with new forms of communication and collaboration. To introduce the opportunity and practicability afforded by DHT, here an exemplar multi-site test is addressed in which a dedicated fibre network and suite of custom software is used to connect the geotechnical centrifuge at the University of Cambridge with a variety of structural dynamics loading apparatus at the University of Oxford and the University of Bristol. While centrifuge time-scaling prevents real-time rates of loading in this test, such experiments may be used to gain valuable insights into physical phenomena, test procedure and accuracy. These and other related experiments have led to the development of the real-time DHT technique and the creation of a flexible framework that aims to facilitate future distributed tests within the UK and beyond. As a further example, a real-time DHT experiment between structural labs using this framework for testing across the Internet is also presented.

  12. Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems

    International Nuclear Information System (INIS)

    Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.

    1978-08-01

    Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentraion reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less

  13. Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems

    International Nuclear Information System (INIS)

    Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.

    1979-01-01

    Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less

  14. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  15. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    Directory of Open Access Journals (Sweden)

    Jared A. Frank

    2016-08-01

    Full Text Available Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  16. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds.

    Science.gov (United States)

    Frank, Jared A; Brill, Anthony; Kapila, Vikram

    2016-08-20

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  17. Comparison of basic laboratory test results with more sophisticated laboratory and in-situ tests methods on soils in southeastern Wisconsin : final report, March 21, 2009.

    Science.gov (United States)

    2009-03-21

    This study investigates all of the generated soils data in an attempt to use the more 'routine' laboratory tests to determine geotechnical design parameters (such as phiangle, cohesion, wet unit weight, unconfined compression, consolidation character...

  18. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    Science.gov (United States)

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  19. Laboratory tests of headache disorders - Dawn of a new era?

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther; Olesen, Jes

    2016-01-01

    secondary headaches. Background In this narrative review we present and discuss published tests that might be useful in phenotyping and/or diagnosis of long-lasting headache disorders such as migraine, tension-type headache, trigeminal autonomic cephalalgias, trigeminal neuralgia and persisting secondary...... headaches. Aim The palpometer test, quantitative sensory testing, nociceptive blink reflex and autonomic tests may be valuable to phenotype and/or diagnose subforms of migraine, tension-type headache, cluster headache, trigeminal neuralgia and medication-overuse headache. Provocation tests with glyceryl...... if well-reputed tertiary headache centers commence developing and implementing laboratory tests in order to improve the classification and treatment of headache patients....

  20. 75 FR 9953 - Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of...

    Science.gov (United States)

    2010-03-04

    ...] Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of the Office of Management and Budget's (OMB) Approval of Information Collection (Paperwork) Requirements AGENCY... its Regulation on the Definition and Requirements for a Nationally Recognized Testing Laboratory (29...

  1. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    Science.gov (United States)

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  2. Proficiency Testing Activities of Frequency Calibration Laboratories in Taiwan, 2009

    Science.gov (United States)

    2009-11-01

    cht.com.tw Abstract In order to meet the requirements of ISO 17025 and the demand of TAF (Taiwan Accreditation Foundation) for calibration inter... IEC 17025 General requirements for the competence of testing and calibration laboratories. The proficiency testing results are then important...on-site evaluation, an assessment team is organized to examine the technical competence of the labs and their compliance with the requirements of ISO

  3. Testing painted wood : past practices at the Forest Products Laboratory and recommendations for future research

    Science.gov (United States)

    R. Sam Williams

    2009-01-01

    A brief history of paint research at the Forest Products Laboratory (FPL) in Madison, Wisconsin, sets the stage for a discussion of testing paint on wood and wood products. Tests include laboratory and outdoor tests, and I discuss them in terms of several degradation mechanisms (loss of gloss and fading, mildew growth, extractives bleed, and cracking, flaking, and...

  4. Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.

    Science.gov (United States)

    Guo, Yuping; Li, Enzhong

    2016-01-01

    This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.

  5. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    Science.gov (United States)

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  6. From laboratory corrosion tests to a corrosion lifetime for wood fasteners : progress and challenges

    Science.gov (United States)

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2010-01-01

    Determining a “corrosion-lifetime” for fasteners embedded in wood treated with recently adopted preservative systems depends upon successfully relating results of laboratory tests to in-service conditions. In contrast to laboratory tests where metal is embedded in wood at constant temperature and moisture content, the in-service temperature and moisture content of wood...

  7. Laboratory tests on dark energy

    International Nuclear Information System (INIS)

    Beck, Christian

    2006-01-01

    The physical nature of the currently observed dark energy in the universe is completely unclear, and many different theoretical models co-exist. Nevertheless, if dark energy is produced by vacuum fluctuations then there is a chance to probe some of its properties by simple laboratory tests based on Josephson junctions. These electronic devices can be used to perform 'vacuum fluctuation spectroscopy', by directly measuring a noise spectrum induced by vacuum fluctuations. One would expect to see a cutoff near 1.7 THz in the measured power spectrum, provided the new physics underlying dark energy couples to electric charge. The effect exploited by the Josephson junction is a subtile nonlinear mixing effect and has nothing to do with the Casimir effect or other effects based on van der Waals forces. A Josephson experiment of the suggested type will now be built, and we should know the result within the next 3 years

  8. IMAGE Project: Results of Laboratory Tests on Tracers for Supercritical Conditions.

    Science.gov (United States)

    Brandvoll, Øyvind; Opsahl Viig, Sissel; Nardini, Isabella; Muller, Jiri

    2016-04-01

    The use of tracers is a well-established technique for monitoring dynamic behaviour of water and gas through a reservoir. In geothermal reservoirs special challenges are encountered due to high temperatures and pressures. In this work, tracer candidates for monitoring water at supercritical conditions (temperature > 374°C, pressure ca 218 bar), are tested in laboratory experiments. Testing of tracers at supercritical water conditions requires experimental set-ups which tolerate harsh conditions with respect to high temperature and pressure. In addition stringent HES (health, environment and safety) factors have to be taken into consideration when designing and performing the experiments. The setup constructed in this project consists of a pressure vessel, high pressure pump, instrumentation for pressure and temperature control and instrumentation required for accurate sampling of tracers. In order to achieve accurate results, a special focus has been paid to the development of the tracer sampling technique. Perfluorinated cyclic hydrocarbons (PFCs) have been selected as tracer candidates. This group of compounds is today commonly used as gas tracers in oil reservoirs. According to the literature they are stable at temperatures up to 400°C. To start with, five PFCs have been tested for thermal stability in static experiments at 375°C and 108 bar in the experimental setup described above. The tracer candidates will be further tested for several months at the relevant conditions. Preliminary results indicate that some of the PFC compounds show stability after three months. However, in order to arrive at conclusive results, the experiments have to be repeated over a longer period and paying special attention to more accurate sampling procedures.

  9. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil

    Directory of Open Access Journals (Sweden)

    Sheila Cristina Lordelo Wludarski

    Full Text Available CONTEXT AND OBJECTIVE: Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community laboratories in Brazil. DESIGN AND SETTING: Retrospective study at a reference pathology laboratory. METHODS: The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. RESULTS: There was concordance in 89.4% (447/500 cases and 85.0% (425/500 cases of the results from estrogen (κ = 0.744, P < 0.001 and progesterone (κ = 0.688, P < 0.001 receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. CONCLUSION: Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  10. 78 FR 7460 - Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program

    Science.gov (United States)

    2013-02-01

    ...] Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program AGENCY: Occupational Safety and Health Administration (OSHA), Labor. ACTION: Notice of stakeholder meeting. SUMMARY: OSHA invites interested parties to attend an informal stakeholder meeting concerning Nationally Recognized Testing...

  11. Syphilis testing practices in the Americas.

    Science.gov (United States)

    Trinh, Thuy T; Kamb, Mary L; Luu, Minh; Ham, D Cal; Perez, Freddy

    2017-09-01

    To present the findings of the Pan American Health Organization's 2014 survey on syphilis testing policies and practices in the Americas. Representatives of national/regional reference and large, lower-level laboratories from 35 member states were invited to participate. A semi-structured, electronically administered questionnaire collected data on syphilis tests, algorithms, equipment/commodities, challenges faced and basic quality assurance (QA) strategies employed (i.e. daily controls, standard operating procedures, technician training, participating in external QA programmes, on-site evaluations). The 69 participating laboratories from 30 (86%) member states included 41 (59%) national/regional reference and 28 (41%) lower-level laboratories. Common syphilis tests conducted were the rapid plasma reagin (RPR) (62% of surveyed laboratories), venereal disease research laboratory (VDRL) (54%), fluorescent treponemal antibody absorption (FTA-ABS) (41%) and Treponema pallidum haemagglutination assay (TPHA) (32%). Only three facilities reported using direct detection methods, and 28 (41% overall, 32% of lower-level facilities) used rapid tests. Most laboratories (62%) used only traditional testing algorithms (non-treponemal screening and treponemal confirmatory testing); however, 12% used only a reverse sequence algorithm (treponemal test first), and 14% employed both algorithms. Another nine (12%) laboratories conducted only one type of serologic test. Although most reference (97%) and lower-level (89%) laboratories used at least one QA strategy, only 16% reported using all five basic strategies. Commonly reported challenges were stock-outs of essential reagents or commodities (46%), limited staff training (73%) and insufficient equipment (39%). Many reference and clinical laboratories in the Americas face challenges in conducting appropriate syphilis testing and in ensuring quality of testing. © 2017 John Wiley & Sons Ltd The Pan-American Health Organization retains

  12. Optimizing Tuberculosis Testing for Basic Laboratories

    Science.gov (United States)

    Ramos, Eric; Schumacher, Samuel G.; Siedner, Mark; Herrera, Beatriz; Quino, Willi; Alvarado, Jessica; Montoya, Rosario; Grandjean, Louis; Martin, Laura; Sherman, Jonathan M.; Gilman, Robert H.; Evans, Carlton A.

    2010-01-01

    Optimal tuberculosis testing usually involves sputum centrifugation followed by broth culture. However, centrifuges are biohazardous and scarce in the resource-limited settings where most tuberculosis occurs. To optimize tuberculosis testing for these settings, centrifugation of 111 decontaminated sputum samples was compared with syringe-aspiration through polycarbonate membrane-filters that were then cultured in broth. To reduce the workload of repeated microscopic screening of broth cultures for tuberculosis growth, the colorimetric redox indicator 2,3-diphenyl-5-(2-thienyl) tetrazolium chloride was added to the broth, which enabled naked-eye detection of culture positivity. This combination of filtration and colorimetric growth-detection gave similar results to sputum centrifugation followed by culture microscopy regarding mean colony counts (43 versus 48; P = 0.6), contamination rates (0.9% versus 1.8%; P = 0.3), and sensitivity (94% versus 95%; P = 0.7), suggesting equivalency of the two methods. By obviating centrifugation and repeated microscopic screening of cultures, this approach may constitute a more appropriate technology for rapid and sensitive tuberculosis diagnosis in basic laboratories. PMID:20889887

  13. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from

  14. Drilling induced damage of core samples. Evidences from laboratory testing and numerical modelling

    International Nuclear Information System (INIS)

    Lanaro, Flavio

    2008-01-01

    Extensive sample testing in uniaxial and Brazilian test conditions were carried out for the Shobasama and MIU Research Laboratory Site (Gifu Pref., Japan). The compressive and tensile strength of the samples was observed to be negatively correlated to the in-situ stress components. Such correlation was interpreted as stress-release induced sample damage. Similar stress conditions were then numerically simulated by means of the BEM-DDM code FRACOD 2D in plane strain conditions. This method allows for explicitly consider the influence of newly initiated or propagating fractures on the stress field and deformation of the core during drilling process. The models show that already at moderate stress levels some fracturing of the core during drilling might occur leading to reduced laboratory strength of the samples. Sample damage maps were produced independently from the laboratory test results and from the numerical models and show good agreement with each other. (author)

  15. Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials

    Science.gov (United States)

    Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.

    2011-12-01

    The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk

  16. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    Science.gov (United States)

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  17. Radioactive material package testing capabilities at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Hohnstreiter, G.F.

    1995-01-01

    Evaluation and certification of radioactive and hazardous material transport packages can be accomplished by subjecting these packages to normal transport and hypothetical accident test conditions. The regulations allow package designers to certify packages using analysis, testing, or a combination of analysis and testing. Testing can be used to substantiate assumptions used in analytical models and to demonstrate package structural and thermal response. Regulatory test conditions include impact, puncture, crush, penetration, water spray, immersion, and thermal environments. Testing facilities are used to simulate the required test conditions and provide measurement response data. Over the past four decades, comprehensive testing facilities have been developed at Sandia National Laboratories to perform a broad range of verification and certification tests on hazardous and radioactive material packages or component sections. Sandia's facilities provide an experience base that has been established during the development and certification of many package designs. These unique facilities, along with innovative instrumentation data collection capabilities and techniques, simulate a broad range of testing environments. In certain package designs, package testing can be an economical alternative to complex analysis to resolve regulatory questions or concerns

  18. Asphalt Mixture Fatigue Testing : Influence of Test Type and Specimen Size

    NARCIS (Netherlands)

    Li, N.

    2013-01-01

    Fatigue characterization of an asphalt mixture is commonly estimated by laboratory fatigue tests. Based on the classical fatigue analysis, fatigue lives obtained from different test devices are not comparable even when they are performed at the same test conditions. It is believed that there are two

  19. Proficiency Test Program Involvement as a Tool for External Quality Control for Radiochemistry and Environmental Laboratory, Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Wo, Y.M.; Zal U'yun Wan Mahmood; Norfaizal Mohamed; Abdul Kadir Ishak; Noor Fadzilah Yusof; Jalal Sharib

    2016-01-01

    As the only Laboratory in Malaysia under the IAEA Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) Network, the Radiochemistry and Environmental Laboratory (RAS), Malaysian Nuclear Agency participates in the proficiency test programmes organised by ALMERA to achieve mutual acceptance of analytical data. The ALMERA has been providing quality support of proficiency tests using sets of different samples matrices and radionuclide levels typically encountered in environmental and food monitoring laboratories. The involvement of RAS laboratory in the IAEA proficiency tests gives opportunity to improve the laboratory capability and personnel skills in the field of radioactivity testing. (author)

  20. Insect temperature-body size trends common to laboratory, latitudinal and seasonal gradients are not found across altitudes

    DEFF Research Database (Denmark)

    Horne, Curtis R.; Hirst, Andrew G.; Atkinson, David

    2018-01-01

    Body size affects rates of most biological and ecological processes, from individual performance to ecosystem function, and is fundamentally linked to organism fitness. Within species, size at maturity can vary systematically with environmental temperature in the laboratory and across seasons...... altitude. Although the general direction of body size clines along altitudinal gradients has been examined previously, to our knowledge altitude-body size (A-S) clines have never been synthesised quantitatively, nor compared with temperature-size (T-S) responses measured under controlled laboratory......, as well as over latitudinal gradients. Recent meta-analyses have revealed a close match in the magnitude and direction of these size gradients in various arthropod orders, suggesting that these size responses share common drivers. As with increasing latitude, temperature also decreases with increasing...

  1. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  2. Laboratory informatics based evaluation of methylene tetrahydrofolate reductase C677T genetic test overutilization

    Directory of Open Access Journals (Sweden)

    David A Cohen

    2013-01-01

    Full Text Available Background: Laboratory data can provide a wide range of information to estimate adherence to guidelines and proper utilization of genetic testing. The methylene tetrahydrofolate reductase (MTHFR C677T variant has been demonstrated to have negligible utility in patient management. However, the testing of this variant remains pervasive. The purpose of this study was to develop methods to analyze concordance of clinician ordering practices with national guidelines. Methods: We used laboratory data to extract specific data elements including patient demographics, timestamps, physician ordering logs and temporal relationship to chemistry requests to examine 245 consecutive MTHFR tests ordered in 2011 at an academic tertiary center. A comprehensive chart review was used to identify indications for testing. These results were correlated with a retrospective analysis of 4,226 tests drawn at a range of hospitals requesting testing from a national reference laboratory over a 2-year period. MTHFR ordering practices drawn from 17 institutions were examined longitudinally from 2002 to 2011. Results: Indications for testing included cerebrovascular events (40.0% and venous thrombosis (39.1%. Family history prompted testing in eight cases. Based on acceptable hypercoagulability guidelines recommending MTHFR C677T testing only in the presence of elevated serum homocysteine, 10.6% (22/207 of adult patients met an indicated threshold at an academic tertiary center. Among 77 institutions, 14.5% (613/4226 of MTHFR testing met recommendations. Conclusion: We demonstrate an effective method to examine discreet elements of a molecular diagnostics laboratory information system at a tertiary care institution and to correlate these findings at a national level. Retrospective examination of clinicians′ request of MTHFR C677T genetic testing strongly suggests that clinicians have failed to adjust their ordering practices in light of evolving scientific and professional

  3. ISO/IEC 17025–2017 "New requirements to the competence of test and calibration laboratories"

    Directory of Open Access Journals (Sweden)

    Baranova P. O.

    2018-05-01

    Full Text Available due to the continuous improvement of the regulatory framework, there is a growing demand for laboratory centers that provide services in the field of testing. The relevance of the topic lies in the transition of laboratories to the new version of ISO/IEC 17025–2017 «General requirements for the competence of test and calibration laboratories». The article compares two versions of the standard, reveals differences and similarities. And changes in the gradation of changes are also highlighted.

  4. Artificial Neural Network Approach in Laboratory Test Reporting:  Learning Algorithms.

    Science.gov (United States)

    Demirci, Ferhat; Akan, Pinar; Kume, Tuncay; Sisman, Ali Riza; Erbayraktar, Zubeyde; Sevinc, Suleyman

    2016-08-01

    In the field of laboratory medicine, minimizing errors and establishing standardization is only possible by predefined processes. The aim of this study was to build an experimental decision algorithm model open to improvement that would efficiently and rapidly evaluate the results of biochemical tests with critical values by evaluating multiple factors concurrently. The experimental model was built by Weka software (Weka, Waikato, New Zealand) based on the artificial neural network method. Data were received from Dokuz Eylül University Central Laboratory. "Training sets" were developed for our experimental model to teach the evaluation criteria. After training the system, "test sets" developed for different conditions were used to statistically assess the validity of the model. After developing the decision algorithm with three iterations of training, no result was verified that was refused by the laboratory specialist. The sensitivity of the model was 91% and specificity was 100%. The estimated κ score was 0.950. This is the first study based on an artificial neural network to build an experimental assessment and decision algorithm model. By integrating our trained algorithm model into a laboratory information system, it may be possible to reduce employees' workload without compromising patient safety. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    Science.gov (United States)

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  6. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Science.gov (United States)

    2010-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  7. Laboratory tests of overpressure differential systems for smoke protection of lobbies

    Science.gov (United States)

    Szałański, Paweł; Misiński, Jacek

    2017-11-01

    Paper presents the methodology of laboratory tests for ventilation overpressure differential systems for smoke protection of lobbies. Research area consists of two spaces representing the lobby and the area under fire equipped with proper ventilation installation. This allows testing of overpressure differential systems for smoke protection of lobbies. Moreover, piece of laboratory tests results for two selected smoke protection systems for lobbies are presented. First one is standard system with constantly opened transfer-damper mounted between lobby and area under fire. Second one - system with so called "electronic transfer" based on two dampers (supplying air to a lobby and to unprotected area alternatively). Opening and closing both dampers is electronically controlled. Changes of pressure difference between lobby and fire affected area during closing and opening doors between those spaces is presented. Conclusions, concerning the possibility of meeting the time period criteria of pressure difference stabilization required by standards, are presented and discussed for both systems.

  8. Common Risk Criteria Standards for National Test Ranges

    Science.gov (United States)

    2016-08-01

    supplemental) document to RCC Document 321. a. Modified aircraft vulnerability criteria for business class jets. b. Modified the aircraft vulnerability... successful , the logical relationships among criteria used at the test ranges and across different hazards are often difficult to comprehend. The...provides a common set of range safety policies, risk criteria, and guidelines for managing risk to people and assets during manned and unmanned

  9. 77 FR 39501 - Current List of Laboratories and Instrumented Initial Testing Facilities Which Meet Minimum...

    Science.gov (United States)

    2012-07-03

    ...-202-2783, (Formerly: Forensic Toxicology Laboratory Baptist Medical Center) Clinical Reference Lab... Minneapolis Veterans Affairs Medical Center, Forensic Toxicology Laboratory, 1 Veterans Drive, Minneapolis, MN... 65203, 573-882-1273 U.S. Army Forensic Toxicology Drug Testing Laboratory, 2490 Wilson St., Fort George...

  10. Biomagnification of hexachlorobenzene: influence of uptake routes in a laboratory test

    International Nuclear Information System (INIS)

    Egeler, P.; Meller, M.; Roembke, J.; Spoerlein, P.

    2001-01-01

    In order to evaluate such a potential biomagnification, a laboratory test was developed. It consisted of a two-step food chain including the sediment dwelling freshwater oligochaete Tubifex tubifex (Mueller) and the three-spined stickleback (Gasterosteus aculeatus, Linne), a small teleost fish which often feeds primarily on benthic invertebrates. Artificial sediment and reconstituted water were used. To examine the influence of benthic prey on the bioaccumulation of a POP in the predator, fish were exposed to 14 C-labelled hexachlorobenzene via spiked water, spiked sediment, pre-contaminated prey organisms, and to combinations of these exposure routes. Summarising the results of these experiments, it could be shown that the exposure to HCB via different routes resulted in a significantly higher accumulation in fish than an exposure to single pathways. It was concluded that the major uptake routes for fish were the overlying water and the food, whereas the contribution of spiked sediment itself was relatively small. HCB was biomagnified in the tested laboratory food chain. Therefore, concerning secondary poisoning, the environmental risk assessment of POPs like HCB should not be based on existing bioaccumulation tests alone, since they focus only on exposure via the water pathway. Instead, the influence of food and sediment as exposure routes should be considered as well, using comprehensive food chain modelling and/or laboratory studies. (orig.) [de

  11. Use of the laboratory tests of soil modulus in modelling pile behaviour

    Science.gov (United States)

    Dyka, Ireneusz

    2012-10-01

    This article deals with the question of theoretical description of behaviour of a single pile rested in a layered soil medium. Particular attention is paid to soil modulus which is used in calculation method for pile load-settlement curve. A brief analysis of the results obtained by laboratory tests to assess soil modulus and its nonlinear variability has been presented. The results of tests have been used in triaxial apparatus and resonant column/torsional shear device. There have also been presented the results of load-settlement calculation for a single pile under axial load with implementation of different models of soil modulus degradation. On this basis, possibilities of using particular kinds of laboratory tests in calculation procedure of foundation settlement have been presented as well as further developments of them.

  12. HVPTF-The high voltage laboratory for the ITER Neutral Beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzi, A., E-mail: antonio.delorenzi@igi.cnr.it [Consorzio RFX-Associazione EURATOM-ENEA per la Fusione Corso Stati Uniti 4, 35127 Padova (Italy); Pilan, N.; Lotto, L.; Fincato, M. [Consorzio RFX-Associazione EURATOM-ENEA per la Fusione Corso Stati Uniti 4, 35127 Padova (Italy); Pesavento, G.; Gobbo, R. [DIE, Universita di Padova, Via Gradenigo 6A, I-35100 Padova (Italy)

    2011-10-15

    In the MITICA research program for the construction of the ITER Neutral Beam Injector prototype, a Laboratory for the investigation on high voltage holding in vacuum has been set up. This Laboratory - HVPTF: High Voltage Padova Test Facility - is presently capable of experiments up to 300 kV dc, and planned for the upgrade to 800 kV. The specific mission for this ancillary lab is the support to the electrostatic design and construction of the MITICA accelerator and the development and testing of HV components to be installed inside the MITICA accelerator during its operation. The paper describes the structure of the lab, characterized by a high degree of automation and reports the results of the commissioning at 300 kV and the first results of voltage holding between test electrodes.

  13. HVPTF-The high voltage laboratory for the ITER Neutral Beam test facility

    International Nuclear Information System (INIS)

    De Lorenzi, A.; Pilan, N.; Lotto, L.; Fincato, M.; Pesavento, G.; Gobbo, R.

    2011-01-01

    In the MITICA research program for the construction of the ITER Neutral Beam Injector prototype, a Laboratory for the investigation on high voltage holding in vacuum has been set up. This Laboratory - HVPTF: High Voltage Padova Test Facility - is presently capable of experiments up to 300 kV dc, and planned for the upgrade to 800 kV. The specific mission for this ancillary lab is the support to the electrostatic design and construction of the MITICA accelerator and the development and testing of HV components to be installed inside the MITICA accelerator during its operation. The paper describes the structure of the lab, characterized by a high degree of automation and reports the results of the commissioning at 300 kV and the first results of voltage holding between test electrodes.

  14. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    Science.gov (United States)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  15. Choosing the right laboratory: a review of clinical and forensic toxicology services for urine drug testing in pain management.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2015-01-01

    Urine drug testing (UDT) services are provided by a variety of clinical, forensic, and reference/specialty laboratories. These UDT services differ based on the principal activity of the laboratory. Clinical laboratories provide testing primarily focused on medical care (eg, emergency care, inpatients, and outpatient clinics), whereas forensic laboratories perform toxicology tests related to postmortem and criminal investigations, and drug-free workplace programs. Some laboratories now provide UDT specifically designed for monitoring patients on chronic opioid therapy. Accreditation programs for clinical laboratories have existed for nearly half a century, and a federal certification program for drug-testing laboratories was established in the 1980s. Standards of practice for forensic toxicology services other than workplace drug testing have been established in recent years. However, no accreditation program currently exists for UDT in pain management, and this review considers several aspects of laboratory accreditation and certification relevant to toxicology services, with the intention to provide guidance to clinicians in their selection of the appropriate laboratory for UDT surveillance of their patients on opioid therapy.

  16. Laboratory Tests for Dispersive Soil Viscosity Determining

    Science.gov (United States)

    Ter-Martirosyan, Z. G.; Ter-Martirosyan, A. Z.; Sobolev, E. S.

    2017-11-01

    There are several widespread methods for soil viscosity determining now. The standard shear test device and torsion test apparatus are the most commonly used installations to do that. However, the application of them has a number of disadvantages. Therefore, the specialists of Moscow State University of Civil Engineering proposed a new device to determine the disperse soil viscosity on the basis of a stabilometer with the B-type camera (viscosimeter). The paper considers the construction of a viscosimeter and the technique for determining soil viscosity inside this tool as well as some experimental verification results of its work.

  17. Efficacy of common laboratory disinfectants and heat on killing trypanosomatid parasites

    Directory of Open Access Journals (Sweden)

    Tyler Kevin M

    2008-09-01

    Full Text Available Abstract The disinfectants TriGene, bleach, ethanol and liquid hand soap, and water and temperature were tested for their ability to kill bloodstream forms of Trypanosoma brucei, epimastigotes of Trypanosoma rangeli and promastigotes of Leishmania major. A 5-min exposure to 0.2% TriGene, 0.1% liquid hand soap and 0.05% bleach (0.05% NaOCl killed all three trypanosomatids. Ethanol and water destroyed the parasites within 5 min at concentrations of 15–17.5% and 80–90%, respectively. All three organisms were also killed when treated for 5 min at 50°C. The results indicate that the disinfectants, water and temperature treatment (i.e. autoclaving are suitable laboratory hygiene measures against trypanosomatid parasites.

  18. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  19. Portuguese Family Physicians' Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Luísa Sá

    Full Text Available Physicians' ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests.A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician's level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician's cost estimate was compared with the true cost and the absolute error was calculated.One-quarter (24%; 95% confidence interval: 23%-25% of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53-56 overestimating and 21% (95% IC: 20-22 underestimating the true actual cost. The majority (76% of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82% said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain.Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care.

  20. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    Science.gov (United States)

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  1. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  2. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  3. Black holes a laboratory for testing strong gravity

    CERN Document Server

    Bambi, Cosimo

    2017-01-01

    This textbook introduces the current astrophysical observations of black holes, and discusses the leading techniques to study the strong gravity region around these objects with electromagnetic radiation. More importantly, it provides the basic tools for writing an astrophysical code and testing the Kerr paradigm. Astrophysical black holes are an ideal laboratory for testing strong gravity. According to general relativity, the spacetime geometry around these objects should be well described by the Kerr solution. The electromagnetic radiation emitted by the gas in the inner part of the accretion disk can probe the metric of the strong gravity region and test the Kerr black hole hypothesis. With exercises and examples in each chapter, as well as calculations and analytical details in the appendix, the book is especially useful to the beginners or graduate students who are familiar with general relativity while they do not have any background in astronomy or astrophysics.

  4. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults.

    Science.gov (United States)

    Kim, Sung Ryeol; Park, Hye Jung; Park, Kyung Hee; Lee, Jae-Hyun; Park, Jung-Won

    2016-08-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was detected most frequently, at a rate of 25.4%. Sensitization rates to other food allergens were as follows: maize grain (13.4%), shrimp (11.9%), almond (11.1%), wheat flour (8.2%), lobster (8.2%), buckwheat (8.2%), mackerel (5.2%), pollack (5.2%), halibut (4.5%), peanut (4.5%), anchovy (4.4%), squid (3.7%), saury (3.0%), common eel (3.0%), yellow corvina (3.0%), hairtail (2.2%), octopus (2.2%), and others. In addition to well-known food allergens, sensitivity to mackerel, chrysalis, pollack, and halibut, which are popular foods in Korea, was observed at high rates in Korean adults. We suggest that the SPT panel for food allergy in Korea should include these allergens.

  5. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults

    Science.gov (United States)

    2016-01-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was detected most frequently, at a rate of 25.4%. Sensitization rates to other food allergens were as follows: maize grain (13.4%), shrimp (11.9%), almond (11.1%), wheat flour (8.2%), lobster (8.2%), buckwheat (8.2%), mackerel (5.2%), pollack (5.2%), halibut (4.5%), peanut (4.5%), anchovy (4.4%), squid (3.7%), saury (3.0%), common eel (3.0%), yellow corvina (3.0%), hairtail (2.2%), octopus (2.2%), and others. In addition to well-known food allergens, sensitivity to mackerel, chrysalis, pollack, and halibut, which are popular foods in Korea, was observed at high rates in Korean adults. We suggest that the SPT panel for food allergy in Korea should include these allergens. PMID:27478328

  6. [Standardization of terminology in laboratory medicine I].

    Science.gov (United States)

    Yoon, Soo Young; Yoon, Jong Hyun; Min, Won Ki; Lim, Hwan Sub; Song, Junghan; Chae, Seok Lae; Lee, Chang Kyu; Kwon, Jung Ah; Lee, Kap No

    2007-04-01

    Standardization of medical terminology is essential for data transmission between health-care institutions or clinical laboratories and for maximizing the benefits of information technology. Purpose of our study was to standardize the medical terms used in the clinical laboratory, such as test names, units, terms used in result descriptions, etc. During the first year of the study, we developed a standard database of concept names for laboratory terms, which covered the terms used in government health care centers, their branch offices, and primary health care units. Laboratory terms were collected from the electronic data interchange (EDI) codes from National Health Insurance Corporation (NHIC), Logical Observation Identifier Names and Codes (LOINC) database, community health centers and their branch offices, and clinical laboratories of representative university medical centers. For standard expression, we referred to the English-Korean/ Korean-English medical dictionary of Korean Medical Association and the rules for foreign language translation. Programs for mapping between LOINC DB and EDI code and for translating English to Korean were developed. A Korean standard laboratory terminology database containing six axial concept names such as components, property, time aspect, system (specimen), scale type, and method type was established for 7,508 test observations. Short names and a mapping table for EDI codes and Unified Medical Language System (UMLS) were added. Synonym tables for concept names, words used in the database, and six axial terms were prepared to make it easier to find the standard terminology with common terms used in the field of laboratory medicine. Here we report for the first time a Korean standard laboratory terminology database for test names, result description terms, result units covering most laboratory tests in primary healthcare centers.

  7. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    Science.gov (United States)

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  8. Testing laboratories, its function in ensuring industrial safety

    International Nuclear Information System (INIS)

    Sanchez Fernandez, M.

    2015-01-01

    This article discusses and justifies the development of industrial laboratories (testing and calibration) in Spain, since its embryo, its creation and development, to the present day. Likewise, presents its interrelation with other agents, as well as the legislative and technical framework is application along to the years. Within this development of the sector, highlights the period of the conformity assessment, and consequently its relationship with Industrial safety. Finally, describes the organizational situation of the sector both nationally and internationally. (Author)

  9. Advanced laboratory for testing plasma thrusters and Hall thruster measurement campaign

    Directory of Open Access Journals (Sweden)

    Szelecka Agnieszka

    2016-06-01

    Full Text Available Plasma engines are used for space propulsion as an alternative to chemical thrusters. Due to the high exhaust velocity of the propellant, they are more efficient for long-distance interplanetary space missions than their conventional counterparts. An advanced laboratory of plasma space propulsion (PlaNS at the Institute of Plasma Physics and Laser Microfusion (IPPLM specializes in designing and testing various electric propulsion devices. Inside of a special vacuum chamber with three performance pumps, an environment similar to the one that prevails in space is created. An innovative Micro Pulsed Plasma Thruster (LμPPT with liquid propellant was built at the laboratory. Now it is used to test the second prototype of Hall effect thruster (HET operating on krypton propellant. Meantime, an improved prototype of krypton Hall thruster is constructed.

  10. Laboratory testing in the emergency department: an Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC and Academy of Emergency Medicine and Care (AcEMC consensus report

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2017-04-01

    Full Text Available The mainstay of patient-oriented laboratory testing in emergency settings entails selecting number and type of tests according to valid criteria of appropriateness. Since the pattern of urgent tests requesting is variable across different institutions, we designed a joined survey between the Academy of Emergency Medicine and Care (AcEMC and the Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC for reaching tentative consensus about the most informative diagnostic tests in emergency settings. A survey, containing the most commonly performed urgent laboratory tests and the relative clinical indications, was disseminated to eight relevant members of AcEMC and eight relevant members of SIBioC. All contributors were asked to provide numerical scores for the different laboratory parameters, where 1 indicated strongly recommended, 2 recommended in specific circumstances, and 3 strongly discouraged. The mean results of the survey were presented as the mean of responders’ values, and the parameters were finally classified as strongly recommended (mean value, 1.0-1.5, somehow recommended (mean value, 1.5-2.0, discouraged (mean value, 2.0-2.5 and strongly discouraged (mean value, 2.5-3.0. The results of the survey allowed defining a hierarchy of priority, wherein 24 tests were strongly recommended. The use of 5 common tests was instead strongly discouraged. For 16 additional parameters in the list, the consensus ranged between somehow recommended and discouraged. We hope that results presented in this joint AcEMC-SIBioC consensus document may help harmonizing panel of tests and requesting patters in emergency setting, at least at a national level.

  11. Laboratory testing and economic analysis of high RAP warm mixed asphalt.

    Science.gov (United States)

    2009-03-24

    This report contains laboratory testing, economic analysis, literature review, and information obtained from multiple producers throughout the state of Mississippi regarding the use of high RAP (50 % to 100%) mixtures containing warm mix additives. T...

  12. Summary of microsatellite instability test results from laboratories participating in proficiency surveys: proficiency survey results from 2005 to 2012.

    Science.gov (United States)

    Boyle, Theresa A; Bridge, Julia A; Sabatini, Linda M; Nowak, Jan A; Vasalos, Patricia; Jennings, Lawrence J; Halling, Kevin C

    2014-03-01

    The College of American Pathologists surveys are the largest laboratory peer comparison programs in the world. These programs allow laboratories to regularly evaluate their performance and improve the accuracy of the patient test results they provide. Proficiency testing is offered twice a year to laboratories performing microsatellite instability testing. These surveys are designed to emulate clinical practice, and some surveys have more challenging cases to encourage the refinement of laboratory practices. This report summarizes the results and trends in microsatellite instability proficiency testing from participating laboratories from the inception of the program in 2005 through 2012. We compiled and analyzed data for 16 surveys of microsatellite instability proficiency testing during 2005 to 2012. The number of laboratories participating in the microsatellite instability survey has more than doubled from 42 to 104 during the 8 years analyzed. An average of 95.4% of the laboratories correctly classified each of the survey test samples from the 2005A through 2012B proficiency challenges. In the 2011B survey, a lower percentage of laboratories (78.4%) correctly classified the specimen, possibly because of overlooking subtle changes of microsatellite instability and/or failing to enrich the tumor content of the specimen to meet the limit of detection of their assay. In general, laboratories performed well in microsatellite instability testing. This testing will continue to be important in screening patients with colorectal and other cancers for Lynch syndrome and guiding the management of patients with sporadic colorectal cancer.

  13. Effects of the pyrethroid insecticide gamma-cyhalothrin on aquatic invertebrates in laboratory and outdoor microcosm tests

    NARCIS (Netherlands)

    Wijngaarden, van R.P.A.; Barber, I.; Brock, T.C.M.

    2009-01-01

    The sensitivity of a range of freshwater lentic invertebrates to gamma-cyhalothrin (GCH), a single enantiomer of the synthetic pyrethroid lambda-cyhalothrin, was assessed in single species laboratory tests and an outdoor multi-species ecosystem test. The most sensitive species in the laboratory

  14. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  15. Bridging naturalistic and laboratory assessment of memory: the Baycrest mask fit test.

    Science.gov (United States)

    Armson, Michael J; Abdi, Hervé; Levine, Brian

    2017-09-01

    Autobiographical memory tests provide a naturalistic counterpoint to the artificiality of laboratory research methods, yet autobiographical events are uncontrolled and, in most cases, unverifiable. In this study, we capitalised on a scripted, complex naturalistic event - the mask fit test (MFT), a standardised procedure required of hospital employees - to bridge the gap between naturalistic and laboratory memory assessment. We created a test of recognition memory for the MFT and administered it to 135 hospital employees who had undertaken the MFT at various points over the past five years. Multivariate analysis revealed two dimensions defined by accuracy and response bias. Accuracy scores showed the expected relationship to encoding-test delay, supporting the validity of this measure. Relative to younger adults, older adults' memory for this naturalistic event was better than would be predicted from the cognitive ageing literature, a result consistent with the notion that older adults' memory performance is enhanced when stimuli are naturalistic and personally relevant. These results demonstrate that testing recognition memory for a scripted event is a viable method of studying autobiographical memory.

  16. Creating Best Practices for the Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories.

    Science.gov (United States)

    Wangsness, Kathryn; Salfinger, Yvonne; Randolph, Robyn; Shea, Shari; Larson, Kirsten

    2017-07-01

    Laboratory accreditation provides a level of standardization in laboratories and confidence in generated food and feed testing results. For some laboratories, ISO/IEC 17025:2005 accreditation may not be fiscally viable, or a requested test method may be out of the scope of the laboratory's accreditation. To assist laboratories for whom accreditation is not feasible, the Association of Public Health Laboratories Data Acceptance Work Group developed a white paper entitled "Best Practices for Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories." The basic elements of a quality management system, along with other best practices that state and local food and feed testing laboratories should follow, are included in the white paper. It also covers program-specific requirements that may need to be addressed. Communication with programs and end data users is regarded as essential for establishing the reliability and accuracy of laboratory data. Following these suggested best practices can facilitate the acceptance of laboratory data, which can result in swift regulatory action and the quick removal of contaminated product from the food supply, improving public health nationally.

  17. HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia.

    Science.gov (United States)

    Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo

    2018-04-17

    Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  18. Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory

    Science.gov (United States)

    Robinson, Raymond C.; Cuy, Michael D.

    1994-01-01

    The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.

  19. The application of data from proficiency testing to laboratory accreditation according to ISO 17025

    DEFF Research Database (Denmark)

    Heydorn, Kaj

    2008-01-01

    Current methods of testing laboratories for their proficiency in reporting correct measurement results are liable to substantial errors of the 2nd kind. This means that laboratories with deflated uncertainties are accepted as proficient, even though their reported measurement results pave the way...

  20. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY

    Directory of Open Access Journals (Sweden)

    Ana ALASTRUEY-IZQUIERDO

    2015-09-01

    Full Text Available SUMMARYDuring recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  2. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    Science.gov (United States)

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  3. Drug-botanical interactions: a review of the laboratory, animal, and human data for 8 common botanicals.

    Science.gov (United States)

    Shord, Stacy S; Shah, Kanan; Lukose, Alvina

    2009-09-01

    Many Americans use complementary and alternative medicine (CAM) to prevent or alleviate common illnesses, and these medicines are commonly used by individuals with cancer.These medicines or botanicals share the same metabolic and transport proteins, including cytochrome P450 enzymes (CYP), glucuronosyltransferases (UGTs), and P-glycoprotein (Pgp), with over-the-counter and prescription medicines increasing the likelihood of drug-botanical interactions.This review provides a brief description of the different proteins, such as CYPs, UGTs, and Pgp.The potential effects of drug-botanical interactions on the pharmacokinetics and pharmacodynamics of the drug or botanical and a summary of the more common models used to study drug metabolism are described.The remaining portion of this review summarizes the data extracted from several laboratory, animal, and clinical studies that describe the metabolism, transport, and potential interactions of 8 selected botanicals. The 8 botanicals include black cohosh, Echinacea, garlic, Gingko biloba, green tea, kava, milk thistle, and St John's wort; these botanicals are among some of the more common botanicals taken by individuals with cancer.These examples are included to demonstrate how to interpret the different studies and how to use these data to predict the likelihood of a clinically significant drug-botanical interaction.

  4. Toxicity of common ions to marine organisms

    International Nuclear Information System (INIS)

    Pillard, D.A.; DuFresne, D.L.; Evans, J.

    1995-01-01

    Produced waters from oil and gas drilling operations are typically very saline, and these may cause acute toxicity to marine organisms due to osmotic imbalances as well as to an excess or deficiency of specific common ions. In order to better understand the relationship between toxicity and ion concentration, laboratory toxicity tests were conducted using mysid shrimp (Mysidopsis bahia), sheepshead minnow (Cyprinodon variegatus), and inland silverside (Menidia beryllina). For each species the ionic concentration of standard laboratory water was proportionally increased or decreased to produce test solutions with a range of salinities. Organisms were exposed for 48 hours. Individual ions (sodium, potassium, calcium, magnetsium, strontium, chloride, bromide, sulfate, bicarbonate, and borate) were also manipulated to examine individual ion toxicity. The three test species differ in their tolerance of salinity. Mysid shrimp show a marked decrease in survival at salinities less than approximately 5 ppt. Both fish species tolerated low salinity water, however, silversides were less tolerant of saline waters (salinity greater than 40 ppt). There were also significant differences in the responses of the organisms to different ions. The results show that the salinity of the test solution may play an important role in the responses of the organisms to the produced water effluent. Predictable toxicity/ion relationships developed in this study can be used to estimate whether toxicity in a produced water is a result of common ions, salinity, or some other unknown toxicant

  5. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  6. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  7. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  8. Transportable Emissions Testing Laboratory for Alternative Vehicles Emissions Testing

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Nigel

    2012-01-31

    The overall objective of this project was to perform research to quantify and improve the energy efficiency and the exhaust emissions reduction from advanced technology vehicles using clean, renewable and alternative fuels. Advanced vehicle and alternative fuel fleets were to be identified, and selected vehicles characterized for emissions and efficiency. Target vehicles were to include transit buses, school buses, vocational trucks, delivery trucks, and tractor-trailers. Gaseous species measured were to include carbon monoxide, carbon dioxide, oxides of nitrogen, hydrocarbons, and particulate matter. An objective was to characterize particulate matter more deeply than by mass. Accurate characterization of efficiency and emissions was to be accomplished using a state-of-the-art portable emissions measurement system and an accompanying chassis dynamometer available at West Virginia University. These two units, combined, are termed the Transportable Laboratory. An objective was to load the vehicles in a real-world fashion, using coast down data to establish rolling resistance and wind drag, and to apply the coast down data to the dynamometer control. Test schedules created from actual vehicle operation were to be employed, and a specific objective of the research was to assess the effect of choosing a test schedule which the subject vehicle either cannot follow or can substantially outperform. In addition the vehicle loading objective was to be met better with an improved flywheel system.

  9. Laboratory Test Setup for Cyclic Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2017-01-01

    This paper presents a comprehensive description and the considerations regarding the design of a new laboratory test setup for testing cyclic axially loaded piles in sand. The test setup aims at analysing the effect of axial one-way cyclic loading on pile capacity and accumulated displacements....... Another aim was to test a large diameter pile segment with dimensions resembling full-scale piles to model the interface properties between pile and sand correctly. The pile segment was an open-ended steel pipe pile with a diameter of 0.5 m and a length of 1 m. The sand conditions resembled the dense sand...... determined from the API RP 2GEO standard and from the test results indicated over consolidation of the sand. Two initial one-way cyclic loading tests provided results of effects on pile capacity and accumulated displacements in agreement with other researchers’ test results....

  10. Testing a Constrained MPC Controller in a Process Control Laboratory

    Science.gov (United States)

    Ricardez-Sandoval, Luis A.; Blankespoor, Wesley; Budman, Hector M.

    2010-01-01

    This paper describes an experiment performed by the fourth year chemical engineering students in the process control laboratory at the University of Waterloo. The objective of this experiment is to test the capabilities of a constrained Model Predictive Controller (MPC) to control the operation of a Double Pipe Heat Exchanger (DPHE) in real time.…

  11. Comparison of Three Commercial Systems for Identification of Yeasts Commonly Isolated in the Clinical Microbiology Laboratory

    Science.gov (United States)

    Wadlin, Jill K.; Hanko, Gayle; Stewart, Rebecca; Pape, John; Nachamkin, Irving

    1999-01-01

    We evaluated three commercial systems (RapID Yeast Plus System; Innovative Diagnostic Systems, Norcross, Ga.; API 20C Aux; bioMerieux-Vitek, Hazelwood, Mo.; and Vitek Yeast Biochemical Card, bioMerieux-Vitek) against an auxinographic and microscopic morphologic reference method for the ability to identify yeasts commonly isolated in our clinical microbiology laboratory. Two-hundred one yeast isolates were compared in the study. The RapID Yeast Plus System was significantly better than either API 20C Aux (193 versus 167 correct identifications; P clinically relevant yeasts. PMID:10325356

  12. Laboratory performance testing of an extruded bitumen containing a surrogate, sodium nitrate-based, low-level aqueous waste

    International Nuclear Information System (INIS)

    Mattus, A.J.; Kaczmarsky, M.M.

    1986-01-01

    Laboratory results of a comprehensive, regulatory performance test program, utilizing an extruded bitumen and a surrogate, sodium nitrate-based waste, have been compiled at the Oak Ridge National Laboratory (ORNL). Using a 53 millimeter, Werner and Pfleiderer extruder, operated by personnel of WasteChem Corporation of Paramus, New Jersey, laboratory-scale, molded samples of type three, air blown bitumen were prepared for laboratory performance testing. A surrogate, low-level, mixed liquid waste, formulated to represent an actual on-site waste at ORNL, containing about 30 wt % sodium nitrate, in addition to eight heavy metals, cold cesium and strontium was utilized. Samples tested contained three levels of waste loading: that is, forty, fifty and sixty wt % salt. Performance test results include the ninety day ANS 16.1 leach test, with leach indices reported for all cations and anions, in addition to the EP Toxicity test, at all levels of waste loading. Additionally, test results presented also include the unconfined compressive strength and surface morphology utilizing scanning electron microscopy. Data presented include correlations between waste form loading and test results, in addition to their relationship to regulatory performance requirements

  13. Health hazards associated with the use of di-(2-ethylhexyl) phthalate (commonly referred to as DOP) in HEPA filter test

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    Di-(2-ethylhexyl) phthalate (DEHP), commonly referred to as di-octyl phthalate, is an important production chemical in the US. In addition to its major use as an additive in plastics, DEHP is widely used to evaluate the effectiveness of high efficiency particulate air (HEPA) filters. Historically, DEHP was also used in quantitative fit testing for respirators. Evaluations of this compound a decade ago showed that it can induce hepatocellular carcinomas in laboratory animals. Although most Department of Energy (DOE) facilities have since discontinued using DEHP in respirator fit testing, DEHP continues to be used for evaluating HEPA filters. This report summarizes available information on the toxicity, mutagenicity, carcinogenicity, and other hazards and problems posed by DEHP, specifically with reference to HEPA filter testing. Information on work practice improvements as well as the availability and suitability of DEHP substitutes are also presented. This material should assist the DOE in the safe use of this material.

  14. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  15. Test plan for preparing the Rapid Transuranic Monitoring Laboratory for field deployment

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1994-04-01

    This plan describes experimental work that will be performed during fiscal year 1994 to prepare the Rapid Transuranic Monitoring Laboratory (RTML) for routine field use by US Department of Energy (DOE) Environmental Restoration and Waste Management programs. The RTML is a mobile, field-deployable laboratory developed at the Idaho National Engineering Laboratory (INEL) that provides a rapid, cost-effective means of characterizing and monitoring radioactive waste remediation sites for low-level radioactive contaminants. Analytical instruments currently installed in the RTML include an extended-range, germanium photon analysis spectrometer with an automatic sample changer; two, large-area, ionization chamber alpha spectrometers; and four alpha continuous air monitors. The RTML was field tested at the INEL during June 1993 in conjunction with the Buried Waste Integrated Demonstration's remote retrieval demonstration. The major tasks described in this test plan are to (a) evaluate the beta detectors for use in screening soil samples for 90 Sr, (b) upgrade the alpha spectral analysis software programs, and (c) upgrade the photon spectral analysis software programs

  16. Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)

    Science.gov (United States)

    Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized

  17. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing

    NARCIS (Netherlands)

    Busquet, F.; Strecker, R.; Rawlings, J.M.; Belanger, S.E.; Braunbeck, T.; Carr, G.J.; Cenijn, P.H.; Fochtman, P.; Gourmelon, A.; Hübler, N.; Kleensang, A.; Knöbel, M.; Kussatz, C.; Legler, J.; Lillicrap, A.; Martínez-Jerónimo, F.; Polleichtner, C.; Rzodeczko, H.; Salinas, E.; Schneider, K.E.; Scholz, S.; van den Brandhof, E.J.; van der Ven, L.T.; Walter-Rohde, S.; Weigt, S.; Witters, H.; Halder, M.

    2014-01-01

    A The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were

  18. Theoretical basis for transfer of laboratory test results of grain size distribution of coal to real object

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Chodura, J [Politechnika Sladska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1989-01-01

    Evaluates a method for forecasting size distribution of black coal mined by shearer loaders in one coal seam. Laboratory tests for determining coal comminution during cutting and haulage along the face are analyzed. Methods for forecasting grain size distribution of coal under operational conditions using formulae developed on the basis of laboratory tests are discussed. Recommendations for design of a test stand and test conditions are discussed. A laboratory stand should accurately model operational conditions of coal cutting, especially dimensions of the individual elements of the shearer loader, geometry of the cutting drum and cutting tools, and strength characteristics of the coal seam. 9 refs.

  19. Quality control tests in dose calibrators used in research laboratories of IPEN

    International Nuclear Information System (INIS)

    Kuahara, Lilian T.; Junior, Amaury C.R.; Martins, Elaine W.; Dias, Carla R.; Correa, Eduardo de L.; Potiens, Maria da Penha A.

    2013-01-01

    The aim of this study was to do the intercomparison between two dose calibrators used in research laboratories at IPEN-CNEN / SP, one being the Capinted NPL-CRC, of the Laboratorio de Calibracao de Instrumentos (LCI) do IPEN, and the other Capintec CRC-15R of the Centro de Radiofarmacia (CR). The standard sources used for carrying out the comparing tests between the two laboratories were 57 Co, 133 Ba and the 13 7 C s

  20. Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo, Ruben P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bellah, Wendy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-04

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well water is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.

  1. Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

    Science.gov (United States)

    Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.

    2006-01-01

    Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529

  2. Guinea pig maximization tests with formaldehyde releasers. Results from two laboratories

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Boman, A; Hamann, K

    1984-01-01

    The guinea pig maximization test was used to evaluate the sensitizing potential of formaldehyde and 6 formaldehyde releasers (Forcide 78, Germall 115, Grotan BK, Grotan OX, KM 200 and Preventol D2). The tests were carried out in 2 laboratories (Copenhagen and Stockholm), and although we intended...... the procedures to be the same, discrepancies were observed, possibly due to the use of different animal strains, test concentrations and vehicles. The sensitizing potential was in general found to be stronger in Stockholm compared to Copenhagen: formaldehyde sensitized 50% of the guinea pigs in Copenhagen and 95...

  3. International on Workshop Advances in Laboratory Testing & Modelling of Soils and Shales

    CERN Document Server

    Laloui, Lyesse

    2017-01-01

    In this spirit, the ATMSS International Workshop “Advances in Laboratory Testing & Modelling of Soils and Shales” (Villars-sur-Ollon, Switzerland; 18-20 January 2017) has been organized to promote the exchange of ideas, experience and state of the art among major experts active in the field of experimental testing and modelling of soils and shales. The Workshop has been organized under the auspices of the Technical Committees TC-101 “Laboratory Testing”, TC-106 “Unsaturated Soils” and TC-308 “Energy Geotechnics” of the International Society of Soil Mechanics and Geotechnical Engineering. This volume contains the invited keynote and feature lectures, as well as the papers that have been presented at the Workshop. The topics of the lectures and papers cover a wide range of theoretical and experimental research, including unsaturated behaviour of soils and shales, multiphysical testing of geomaterials, hydro–mechanical behaviour of shales and stiff clays, the geomechanical behaviour of the ...

  4. Using pathology-specific laboratory profiles in Clinical Pathology to reduce inappropriate test requesting: two completed audit cycles

    Science.gov (United States)

    2012-01-01

    Background Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Methods Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs’ request forms. Results Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). Conclusions The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the

  5. Mars Science Laboratory Flight Software Boot Robustness Testing Project Report

    Science.gov (United States)

    Roth, Brian

    2011-01-01

    On the surface of Mars, the Mars Science Laboratory will boot up its flight computers every morning, having charged the batteries through the night. This boot process is complicated, critical, and affected by numerous hardware states that can be difficult to test. The hardware test beds do not facilitate testing a long duration of back-to-back unmanned automated tests, and although the software simulation has provided the necessary functionality and fidelity for this boot testing, there has not been support for the full flexibility necessary for this task. Therefore to perform this testing a framework has been build around the software simulation that supports running automated tests loading a variety of starting configurations for software and hardware states. This implementation has been tested against the nominal cases to validate the methodology, and support for configuring off-nominal cases is ongoing. The implication of this testing is that the introduction of input configurations that have yet proved difficult to test may reveal boot scenarios worth higher fidelity investigation, and in other cases increase confidence in the robustness of the flight software boot process.

  6. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  7. Common Core Standards and their Impact on Standardized Test Design

    NARCIS (Netherlands)

    Polleck, J.N.; Jeffery, J.V.

    2017-01-01

    With adoption of the Common Core (CCSS) in a majority of U.S. states came developmentof new high-stakes exams. Though researchers have investigated CCSS andrelated policies, less attention has been directed toward understanding how standardsare translated into testing. Due to the influence that

  8. Testing of a cryogenic recooler heat exchanger at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Nicoletti, A.; Wu, K.C.

    1993-01-01

    Brookhaven National Laboratory has tested a recooler heat exchanger intended to be used in the cryogenic system of the Relativistic Heavy Ion Collider. The unit is required to transfer 225 Watts from a supercritical helium stream flowing at 100 g/s to a helium bath boiling at 4.25 K. Measurements made with heat loads of 50 to over 450 Watts on the unit indicate its cooling capacity is greater than 400 Watts, as expected, and it will be suitable for use in the RHIC ring. Presented are the modifications made to BNL's MAGCOOL test facility that were necessary for testing, test procedure, and recooler performance

  9. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities - A General Overview

    Science.gov (United States)

    Hebert, Phillip W., Sr.; Hughes, Mark S.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Marshall, PeggL.; Duncan, Michael E.; Morris, Jon A.; Franzl, Richard W.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition system (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis' development and deployment.

  10. Common, yet elusive: a case of severe anion gap acidosis.

    Science.gov (United States)

    Agrawal, Akanksha; Kishlyansky, Marina; Biso, Sylvia; Patnaik, Soumya; Punjabi, Chitra

    2017-09-01

    Acid-base disturbances are common occurrence in hospitalized patients with life threatening complications. 5-oxoproline has been increasingly recognized as cause of high anion gap metabolic acidosis (AGMA) in association with chronic acetaminophen use. However, laboratory workup for it are not widely available. We report case of 56-year-old female with severe AGMA not attributable to ketoacidosis, lactic acidosis or toxic ingestion. History was significant for chronic acetaminophen use, and laboratory workup negative for all frequent causes of AGMA. Given history and clinical presentation, our suspicion for 5-oxoproline toxicity was high. Our patient required emergent hemodialysis and subsequently improved clinically. With an increasing awareness of the uncommon causes of high AGMA, tests should be more readily available to detect their presence. Physicians should be more vigilant of underdiagnosed causes of AGMA if the presentation and laboratory values do not reflect a common cause, as definitive treatment may vary based on the offending agent.

  11. Updating the immunology curriculum in clinical laboratory science.

    Science.gov (United States)

    Stevens, C D

    2000-01-01

    To determine essential content areas of immunology/serology courses at the clinical laboratory technician (CLT) and clinical laboratory scientist (CLS) levels. A questionnaire was designed which listed all major topics in immunology and serology. Participants were asked to place a check beside each topic covered. For an additional list of serological and immunological laboratory testing, participants were asked to indicate if each test was performed in either the didactic or clinical setting, or not performed at all. A national survey of 593 NAACLS approved CLT and CLS programs was conducted by mail under the auspices of ASCLS. Responses were obtained from 158 programs. Respondents from all across the United States included 60 CLT programs, 48 hospital-based CLS programs, 45 university-based CLS programs, and 5 university-based combined CLT and CLS programs. The survey was designed to enumerate major topics included in immunology and serology courses by a majority of participants at two distinct educational levels, CLT and CLS. Laboratory testing routinely performed in student laboratories as well as in the clinical setting was also determined for these two levels of practitioners. Certain key topics were common to most immunology and serology courses. There were some notable differences in the depth of courses at the CLT and CLS levels. Laboratory testing associated with these courses also differed at the two levels. Testing requiring more detailed interpretation, such as antinuclear antibody patterns (ANAs), was mainly performed by CLS students only. There are certain key topics as well as specific laboratory tests that should be included in immunology/serology courses at each of the two different educational levels to best prepare students for the workplace. Educators can use this information as a guide to plan a curriculum for such courses.

  12. Inappropriate emergency laboratory test ordering: defensive or peer evidence shared based medicine?

    Directory of Open Access Journals (Sweden)

    C. Descovich

    2013-05-01

    Full Text Available BACKGROUND The laboratory overuse is widely prevalent in hospital practice, mostly in the emergency care. Reasons for excessive and inappropriate test-ordering include defensive behaviour and fear or uncertainty, lack of experience, the misuse of protocols and guidelines, “routine” and local attitudes, inadequate educational feedback and clinician’s unawareness about the cost of examinations and their related implications. AIM OF THE STUDY AND METHODS The primary target of our working group was to reduce inappropriate ordering on a urgent basis test, implementing further examinations not yet previewed in the hospital panel of the available urgencies, according to the evidence based diagnosis concept. The secondary goal was to indicate strategies of re-engineering of the processes, improving turnaround time in the laboratory management of emergencies. After evaluating, as first intervention, the more reliable sources for practice guidelines, systematic reviews and RCTs, the committee further discussed main topics with in-hospital stakeholders, selected from Emergency, Internal Medicine and Surgery Depts. The working group, in many subsequent audits, tried to obtain a systematic feed back with all involved professionals. RESULTS After reviewing literature’s evidence, the board constrained testing options by defining the basic emergency laboratory panel tests (blood type, hemogram, blood urea nitrogen, plasma creatinine, glucose, sodium, potassium, chloride, osmolarity, CRP, bicarbonate, CPK, creatine phosphokinase-MB, myoglobin, troponin, BNP and NT-proBNP, PT-INR, PTT, D-dimer, beta- HCG, biochemical urinalysis etc.. As final result, the proposed tests reduced the overall number of inappropriate investigations and increased, with newer and updated tests, the available panel for critical patients. DISCUSSION A collegiate review of data reporting, in-hospital deepening of problems and the inter- professional discussion of the evidences

  13. Guidelines for establishing quality systems in veterinary diagnostic testing laboratories. Report of a Joint FAO/IAEA consultants meeting/workshop. Draft

    International Nuclear Information System (INIS)

    2002-01-01

    The purpose of this report is to assist veterinary testing laboratories to develop and implement a quality system based on the OIE Standard 'Management and Technical Requirements for Laboratories Conducting Tests for Infectious Animal Diseases'. The introduction to the OIE Standard states: This document describes the OIE Standard for management and technical competence that serves as the basis for accreditation of laboratories that conduct tests for infectious animal diseases, especially those laboratories involved in testing for international trade. It contains the specific requirements unique to laboratories conducting tests for infectious animal diseases. These specific requirements represent an interpretation of the generally stated requirements of ISO/IEC 17025:1999, General requirements for the competence of testing and calibration laboratories (as outlined in Annex B of ISO/IEC 17025). Accreditation bodies that recognize the competence of such testing laboratories may use this Standard as the basis for their accreditation. This report gives an example-oriented overview of the structure and contents of critical documents and procedures such as Quality Manual (QM), Standard Operating Procedures (SOPs), etc. inherent to a quality system and describes the different stages in the implementation of the OIE Standard. For that reason it can be used as a practical guide for the production of necessary documents but also as a help to determine the status of a laboratory during its journey towards establishing a QS

  14. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  15. Harmonization of antimicrobial susceptibility testing among veterinary diagnostic laboratories in the five Nordic countries

    DEFF Research Database (Denmark)

    Petersen, A.; Aarestrup, Frank Møller; Hofshagen, Merete

    2003-01-01

    A total of 100 bacterial strains (25 Escherichia coli, 25 Salmonella enterica, 25 Staphylococcus aureus, and 25 Enterococcus strains) and four reference strains were tested for susceptibility toward 8-12 antimicrobial agents in 12 veterinary diagnostic laboratories in the five Nordic countries...... reported as vancomycin resistant. Ten laboratories identified the Enterococcus spp. to species level. All five Enterococcus faecium and 10 Enterococcus faecalis selected from the strain collection at the Danish Veterinary Institute were correctly identified by all laboratories, whereas some problems were...

  16. EFRT M-12 Issue Resolution: Caustic-Leach Rate Constants from PEP and Laboratory-Scale Tests

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Rassat, Scot D.; Eslinger, Paul W.; Aaberg, Rosanne L.; Aker, Pamela M.; Golovich, Elizabeth C.; Hanson, Brady D.; Hausmann, Tom S.; Huckaby, James L.; Kurath, Dean E.; Minette, Michael J.; Sundaram, S. K.; Yokuda, Satoru T.

    2010-01-01

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. The work described in this report addresses caustic leaching under WTP conditions, based on tests performed with a Hanford waste simulant. Because gibbsite leaching kinetics are rapid (gibbsite is expected to be dissolved by the time the final leach temperature is reached), boehmite leach kinetics are the main focus of the caustic-leach tests. The tests were completed at the laboratory-scale and in the PEP, which is a 1/4.5-scale mock-up of key PTF process equipment. Two laboratory-scale caustic-leach tests were performed for each of the PEP runs. For each PEP run, unleached slurry was taken from the PEP caustic-leach vessel for one batch and used as feed for both of the corresponding laboratory-scale tests.

  17. Estimation of the common cause failure probabilities on the component group with mixed testing scheme

    International Nuclear Information System (INIS)

    Hwang, Meejeong; Kang, Dae Il

    2011-01-01

    Highlights: ► This paper presents a method to estimate the common cause failure probabilities on the common cause component group with mixed testing schemes. ► The CCF probabilities are dependent on the testing schemes such as staggered testing or non-staggered testing. ► There are many CCCGs with specific mixed testing schemes in real plant operation. ► Therefore, a general formula which is applicable to both alternate periodic testing scheme and train level mixed testing scheme was derived. - Abstract: This paper presents a method to estimate the common cause failure (CCF) probabilities on the common cause component group (CCCG) with mixed testing schemes such as the train level mixed testing scheme or the alternate periodic testing scheme. In the train level mixed testing scheme, the components are tested in a non-staggered way within the same train, but the components are tested in a staggered way between the trains. The alternate periodic testing scheme indicates that all components in the same CCCG are tested in a non-staggered way during the planned maintenance period, but they are tested in a staggered way during normal plant operation. Since the CCF probabilities are dependent on the testing schemes such as staggered testing or non-staggered testing, CCF estimators have two kinds of formulas in accordance with the testing schemes. Thus, there are general formulas to estimate the CCF probability on the staggered testing scheme and non-staggered testing scheme. However, in real plant operation, there are many CCCGs with specific mixed testing schemes. Recently, Barros () and Kang () proposed a CCF factor estimation method to reflect the alternate periodic testing scheme and the train level mixed testing scheme. In this paper, a general formula which is applicable to both the alternate periodic testing scheme and the train level mixed testing scheme was derived.

  18. The most common nonconformities encountered during the assessments of medical laboratories in Hong Kong using ISO 15189 as accreditation criteria.

    Science.gov (United States)

    Ho, Bella; Ho, Eric

    2012-01-01

    ISO 15189 was a new standard published in 2003 for accrediting medical laboratories. We believe that some requirements of the ISO 15189 standard are especially difficult to meet for majority of laboratories. The aim of this article was to present the frequency of nonconformities to requirements of the ISO 15189 accreditation standard, encountered during the assessments of medical laboratories in Hong Kong, during 2004 to 2009. Nonconformities reported in assessments based on ISO 15189 were analyzed in two periods - from 2004 to 2006 and in 2009. They are categorized according to the ISO 15189 clause numbers. The performance of 27 laboratories initially assessed between 2004 and 2006 was compared to their performance in the second reassessment in 2009. For management requirements, nonconformities were most frequently reported against quality management system, quality and technical records and document control; whereas for technical requirements, they were reported against examination procedures, equipment, and assuring quality of examination procedures. There was no major difference in types of common nonconformities reported in the two study periods. The total number of nonconformities reported in the second reassessment of 27 laboratories in 2009 was almost halved compared to their initial assessments. The number of significant nonconformities per laboratory significantly decreased (P = 0.023). Similar nonconformities were reported in the two study periods though the frequency encountered decreased. The significant decrease in number of significant nonconformities encountered in the same group of laboratories in the two periods substantiated that 15015189 contributed to quality improvement of accredited laboratories.

  19. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  20. Nuclear magnetic resonance common laboratory, quadrennial report; Laboratoire commun de resonance magnetique nucleaire, rapport quadriennal 1994-1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    This quadrennial report of the nuclear magnetic resonance common laboratory gives an overview of the main activities. Among the different described activities, only one is interesting for the INIS database: it concerns the Solid NMR of cements used for radioactive wastes storage. In this case, the NMR is used to characterize the structure of the material and the composition, structure and kinetics of formation of the alteration layer which is formed at the surface of concrete during water leaching conditions. The NMR methodology is given. (O.M.)

  1. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  2. Correlation of same-visit HbA1c test with laboratory-based measurements: A MetroNet study

    Directory of Open Access Journals (Sweden)

    West Patricia A

    2005-07-01

    Full Text Available Abstract Background Glycated hemoglobin (HbA1c results vary by analytical method. Use of same-visit HbA1c testing methodology holds the promise of more efficient patient care, and improved diabetes management. Our objective was to test the feasibility of introducing a same-visit HbA1c methodology into busy family practice centers (FPC and to calculate the correlation between the same-visit HbA1c test and the laboratory method that the clinical site was currently using for HbA1c testing. Methods Consecutive diabetic patients 18 years of age and older having blood samples drawn for routine laboratory analysis of HbA1c were asked to provide a capillary blood sample for same-visit testing with the BIO-RAD Micromat II. We compared the results of the same-visit test to three different laboratory methods (one FPC used two different laboratories. Results 147 paired samples were available for analysis (73 from one FPC; 74 from the other. The Pearson correlation of Micromat II and ion-exchange HPLC was 0.713 (p Conclusion For each of the laboratory methods, the correlation coefficient was lower than the 0.96 reported by the manufacturer. This might be due to variability introduced by the multiple users of the Micromat II machine. The mean HbA1c results were also consistently lower than those obtained from laboratory analysis. Additionally, the amount of dedicated time required to perform the assay may limit its usefulness in a busy clinical practice. Before introducing a same-visit HbA1c methodology, clinicians should compare the rapid results to their current method of analysis.

  3. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    Science.gov (United States)

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in

  4. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    Directory of Open Access Journals (Sweden)

    Kabani Amin M

    2005-01-01

    Full Text Available Abstract Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3 laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226 was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7% of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18, resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a

  5. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    Science.gov (United States)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  6. Lawrence Livermore Laboratory's beryllium control program for high-explosive test firing bunkers and tables

    International Nuclear Information System (INIS)

    Johnson, J.S.

    1978-01-01

    This detailed report on Lawrence Livermore Laboratory's control program to minimize beryllium levels in Laboratory workplaces includes an outline of beryllium surface, soil, and air levels and an 11-y summary of sampling results from two high-use, high-explosive test firing bunkers. These sampling data and other studies demonstrate that the beryllium control program is funcioning effectively

  7. Lawrence Berkeley laboratory neutral-beam engineering test facility power-supply system

    International Nuclear Information System (INIS)

    Lutz, I.C.; Arthur, C.A.; deVries, G.J.; Owren, H.M.

    1981-10-01

    The Lawrence Berkeley Laboratory is upgrading the neutral beam source test facility (NBSTF) into a neutral beam engineering test facility (NBETF) with increased capabilities for the development of neutral beam systems. The NBETF will have an accel power supply capable of 170 kV, 70 A, 30 sec pulse length, 10% duty cycle; and the auxiliary power supplies required for the sources. This paper describes the major components, their ratings and capabilities, and the flexibility designed to accomodate the needs of source development

  8. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Science.gov (United States)

    2010-01-01

    ... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as... current certification status of laboratories is available from the Division of Workplace Programs, Center... relationship with the licensee's or other entity's MRO(s) that may be construed as a potential conflict of...

  9. The bogus taste test: Validity as a measure of laboratory food intake

    OpenAIRE

    Robinson, Eric; Haynes, Ashleigh; Hardman, Charlotte A.; Kemps, Eva; Higgs, Suzanne; Jones, Andrew

    2017-01-01

    Because overconsumption of food contributes to ill health, understanding what affects how much people eat is of importance. The ?bogus? taste test is a measure widely used in eating behaviour research to identify factors that may have a causal effect on food intake. However, there has been no examination of the validity of the bogus taste test as a measure of food intake. We conducted a participant level analysis of 31 published laboratory studies that used the taste test to measure food inta...

  10. Improvement of the quality control program of the clinical dosimeters calibration laboratory of the IPEN/CNEN-SP

    Energy Technology Data Exchange (ETDEWEB)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor, E-mail: wbdamatto@ipen.br, E-mail: mppotiens@ipen.br, E-mail: vivolo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    A set of clinical dosimeters (thimble ionization chamber coupled to an electrometer) commonly used in radiotherapy in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analysis parameters for the dosimeters behaviour were established, specifying their sensitivities and operating characteristics. Applied tests were: repeatability, reproducibility and current leakage. Thus it was possible to determine the most common defects found in these equipment and the actions that could be taken to prevent it (clinical dosimeters quality control programs). The behaviour of 167 dosimeters was analyzed and in this study, 62 of them have been tested. The main problem detected during calibration tests was current leakage, i.e. electronic noise. The tests were applied to the routine measurements at the Calibration Laboratory implementing an ideal calibration procedure. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of the clinical dosimeters calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  11. Improvement of the quality control program of the clinical dosimeters calibration laboratory of the IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor

    2013-01-01

    A set of clinical dosimeters (thimble ionization chamber coupled to an electrometer) commonly used in radiotherapy in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analysis parameters for the dosimeters behaviour were established, specifying their sensitivities and operating characteristics. Applied tests were: repeatability, reproducibility and current leakage. Thus it was possible to determine the most common defects found in these equipment and the actions that could be taken to prevent it (clinical dosimeters quality control programs). The behaviour of 167 dosimeters was analyzed and in this study, 62 of them have been tested. The main problem detected during calibration tests was current leakage, i.e. electronic noise. The tests were applied to the routine measurements at the Calibration Laboratory implementing an ideal calibration procedure. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of the clinical dosimeters calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  12. Establishing benchmarks and metrics for disruptive technologies, inappropriate and obsolete tests in the clinical laboratory.

    Science.gov (United States)

    Kiechle, Frederick L; Arcenas, Rodney C; Rogers, Linda C

    2014-01-01

    Benchmarks and metrics related to laboratory test utilization are based on evidence-based medical literature that may suffer from a positive publication bias. Guidelines are only as good as the data reviewed to create them. Disruptive technologies require time for appropriate use to be established before utilization review will be meaningful. Metrics include monitoring the use of obsolete tests and the inappropriate use of lab tests. Test utilization by clients in a hospital outreach program can be used to monitor the impact of new clients on lab workload. A multi-disciplinary laboratory utilization committee is the most effective tool for modifying bad habits, and reviewing and approving new tests for the lab formulary or by sending them out to a reference lab. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Multi-laboratory testing of a screening method for world trade center (WTC) collapse dust

    International Nuclear Information System (INIS)

    Rosati, Jacky A.; Bern, Amy M.; Willis, Robert D.; Blanchard, Fredrick T.; Conner, Teri L.; Kahn, Henry D.; Friedman, David

    2008-01-01

    The September 11, 2001 attack on the World Trade Center (WTC) covered a large area of downtown New York City with dust and debris. This paper describes the testing of an analytical method designed to evaluate whether sampled dust contains dust that may have originated from the collapse of the WTC. Using dust samples collected from locations affected and not affected (referred to as 'background' locations) by the collapse, a scanning electron microscopy (SEM) analysis method was developed to screen for three materials that are believed to be present in large quantities in WTC dusts: slag wool, concrete, and gypsum. An inter-laboratory evaluation of the method was implemented by having eight laboratories analyze a number of 'blind' dust samples, consisting of confirmed background dust and confirmed background dust spiked with varying amounts of dust affected by the WTC collapse. The levels of gypsum and concrete in the spiked samples were indistinguishable from the levels in the background samples. Measurements of slag wool in dust demonstrated potential for distinguishing between spiked and background samples in spite of considerable within and between laboratory variability. Slag wool measurements appear to be sufficiently sensitive to distinguish dust spiked with 5% WTC-affected dust from 22 out of 25 background dust samples. Additional development work and inter-laboratory testing of the slag wool component will be necessary to improve the precision and accuracy of the method and reduce inter- and intra-laboratory variability from levels observed in the inter-laboratory evaluation

  14. Nuclear Astrophysics at ELI-NP: the ELISSA prototype tested at Laboratori Nazionali del Sud

    Science.gov (United States)

    Guardo, Giovanni Luca; Anzalone, Antonello; Balabanski, Dimiter; Chesnevskaya, Svetlana; Crucillá, Walter; Filipescu, Dan; Gulino, Marisa; La Cognata, Marco; Lattuada, Dario; Matei, Catalin; Pizzone, Rosario Gianluca; Rapisarda, Giuseppe; Romano, Stefano; Spitaleri, Claudio; Taffara, Alessandra; Tumino, Aurora; Xu, Yi

    2018-01-01

    The Extreme Light Infrastructure-Nuclear Physics (ELI-NP) facility, under construction in Magurele near Bucharest in Romania, will provide high-intensity and high-resolution gamma ray beams that can be used to address hotly debated problems in nuclear astrophysics, such as the accurate measurements of the cross sections of the 24Mg(γ,α)20Ne reaction, that is fundamental to determine the effective rate of 28Si destruction right before the core collapse and the subsequent supernova explosion. For this purpose, a silicon strip detector array (named ELISSA, acronym for Extreme Light Infrastructure Silicon Strip Array) will be realized in a common effort by ELI-NP and Laboratori Nazionali del Sud (INFN-LNS), in order to measure excitation functions and angular distributions over a wide energy and angular range. A prototype of ELISSA was built and tested at INFN-LNS in Catania (Italy) with the support of ELI-NP. In this occasion, we have carried out experiments with alpha sources and with a 11 MeV 7Li beam. Thanks to our approach, the first results of those tests show up a very good energy resolution (better than 1%) and very good position resolution, of the order of 1 mm. Moreover, a threshold of 150 keV can be easily achieved with no cooling.

  15. Room 209 excavation response test in the underground research laboratory

    International Nuclear Information System (INIS)

    Lang, P.A.

    1989-01-01

    An in situ excavation response test was conducted at the Canadian Underground Research Laboratory (URL) in conjunction with excavation of a tunnel (Room 209) through a near-vertical water-bearing fracture oriented perpendicular to the tunnel axis. Encountering a fracture with such desirable characteristics provided a unique opportunity during construction of the URL to try out instrumentation and analytical methods for use in the Excavation Response Experiment (ERE) planned as one of the major URL experiments. The test has produced a valuable data set for validating numerical models. Four modelling groups predicted the response that would be monitored by the instruments. The predictions of the mechanical response were generally good. However, the predictions of the permeability and hydraulic pressure changes in the fracture, and the water flows into the tunnel, were poor. It is concluded that we may not understand the mechanisms that occur in the fracture in response to excavation. Laboratory testing, and development of a contracting joint code, has been initiated to further investigate this phenomenon. Preliminary results indicate that the excavation damaged zone in the walls and crown is less than 0.5 m thick and has relatively low permeability. The damaged zone in the floor is at least 1 m thick and has relatively high permeability. The damage in the floor could be reduced in future excavations by using controlled blasting methods similar to those used for the walls and crown

  16. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    Science.gov (United States)

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  17. Comparison of Estrogen Receptor Assay Results from Pathology Reports with Results from Central Laboratory Testing: Implications for Population-Based Studies of Breast Cancer

    Science.gov (United States)

    Collins, LC; Marotti, J; Baer, HJ; Deitz, AC; Colditz, GA; Tamimi, RM

    2014-01-01

    Population-based studies of women with breast cancer commonly utilize information culled from pathology reports rather than central pathology review. The reliability of this information, particularly with regard to tumor biomarker results, is of concern. To address this, we evaluated the concordance between estrogen receptor (ER) results as determined from the original pathology reports and ER results obtained on the same specimens following testing in a single laboratory. Tissue microarrays (TMAs) were constructed from paraffin blocks of 3,167 breast cancers that developed in women enrolled in the Nurses’ Health Study. ER immunostains were performed on all TMA sections in single run. Results of ER immunostains performed on the TMA sections were compared with ER assay results abstracted from pathology reports. Among 1,851 cases of invasive breast cancer in which both ER results from pathology reports and central ER test results were available, the reported ER status and the ER status as determined from immunostains on TMAs were in agreement in 1,651 cases (87.3 %; kappa value 0.64, ppathology reports is a reasonable, albeit imperfect, alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer. PMID:18230800

  18. Laboratory testing of waste glass aqueous corrosion; effects of experimental parameters

    International Nuclear Information System (INIS)

    Ebert, W.L.; Mazer, J.J.

    1993-01-01

    A literature survey has been performed to assess the effects of the temperature, glass surface area/leachate volume ratio, leachant composition, leachant flow rate, and glass composition (actual radioactive vs. simulated glass) used in laboratory tests on the measured glass reaction rate. The effects of these parameters must be accounted for in mechanistic models used to project glass durability over long times. Test parameters can also be utilized to highlight particular processes in laboratory tests. Waste glass corrosion results as water diffusion, ion-exchange, and hydrolysis reactions occur simultaneously to devitrify the glass and release soluble glass components into solution. The rates of these processes are interrelated by the affects of the solution chemistry and glass alteration phases on each process, and the dominant (fastest) process may change as the reaction progresses. Transport of components from the release sites into solution may also affect the observed corrosion rate. The reaction temperature will affect the rate of each process, while other parameters will affect the solution chemistry and which processes are observed during the test. The early stages of corrosion will be observed under test conditions which maintain dilute leachates and the later stages will be observed under conditions that generate more concentrated leachate solutions. Typically, water diffusion and ion-exchange reactions dominate the observed glass corrosion in dilute solutions while hydrolysis reactions dominant in more concentrated solutions. Which process(es) controls the long-term glass corrosion is not fully understood, and the long-term corrosion rate may be either transport- or reaction-limited

  19. Experimental Modal Test of the Laboratory Model of Steel Truss Structure

    Directory of Open Access Journals (Sweden)

    Kortiš Ján

    2016-12-01

    Full Text Available The experimental modal analysis is often used to validate the accuracy of dynamic numerical models. It is also a good tool to obtain valuable information about current condition of the structures that could help to determine residual lifetime. The quality of modal testing results is highly dependent on the proper estimation of the natural frequencies from the frequency response function. This article presents the experimental modal test of the laboratory steel structure in which the natural frequencies and mode shapes are determined.

  20. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    OpenAIRE

    Jared A. Frank; Anthony Brill; Vikram Kapila

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their em...

  1. The Laboratory Diagnosis of Herpes Simplex Virus Infections

    Directory of Open Access Journals (Sweden)

    Ameeta Singh

    2005-01-01

    Full Text Available Herpes simplex virus (HSV types 1 and 2 cause genital herpes infections and are the most common cause of genital ulcer disease in industrialized nations. Although these infections are very common, the majority of them remain underdiagnosed because they are asymptomatic or unrecognized. A clinical diagnosis of genital herpes should always be confirmed by laboratory testing; this can be accomplished through the use of direct tests for viral isolation, the detection of antigen or, more recently, the detection of HSV DNA using molecular diagnostic techniques. Testing for serotypes is recommended because of the different prognostic and counselling implications. Type-specific HSV serology is becoming more readily available and will enhance the ability to make the diagnosis and guide clinical management in select patients.

  2. An Alternative Approach to Assessing Laboratory and Field Notebooks: The Data Retrieval Test

    Science.gov (United States)

    Bedford, Hilary; Bedford, Alan; Thomas, Judith; Ashton, Paul

    2010-01-01

    Marking field and laboratory notebooks can be a time consuming and tedious task. This article describes a system whereby the contents of student's notebooks are assessed by testing the students on what they have included and their understanding of what has been done. It also tests the quality of the student's notes--detailed, organised notes…

  3. Standard practice for conducting and evaluating laboratory corrosions tests in soils

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers procedures for conducting laboratory corrosion tests in soils to evaluate the corrosive attack on engineering materials. 1.2 This practice covers specimen selection and preparation, test environments, and evaluation of test results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Worldwide proficiency test for X ray fluorescence laboratories PTXRFIAEA/05 determination of minor and trace elements in marine sediment

    International Nuclear Information System (INIS)

    2009-01-01

    The proficiency test (code PTXRFIAEA05) was the fifth worldwide exercise organized by the IAEA Seibersdorf Laboratories in order to assist X ray fluorescence laboratories in assessment and improvement of their analytical performance. The test was carried out within the IAEA Project 1.4.3.4 (D.3.03) on Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of the project was to enhance capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health, agriculture, and in monitoring and evaluation of environmental pollution. Marine sediment test samples with established homogeneity and well characterized known target values of the mass fractions of analytes were distributed to participating laboratories. The laboratories were requested to analyze the sample using established techniques following their analytical procedures. Based on the results of the proficiency test presented in the report each participating laboratory should assess its analytical performance results by using the specified criteria and, if appropriate, to identify discrepancies, and to correct relevant analytical procedures. The next proficiency test exercise will be executed in 2009

  5. ELISA and some biochemical tests of heterophyidae infection in laboratory animals.

    Science.gov (United States)

    El-Seify, Mahmoud A; El-Bahy, Nasr M; Desouky, Abdelrazek Y; Bazh, Eman K

    2012-02-01

    Heterophyiasis is an important food-borne parasitic zoonosis in Egypt, among the inhabitants living around brackish-water lakes especially fishermen, and it is a common human parasite in the Nile Delta. The experiment was done on two laboratory animals (rats and dogs), and the time of sample collection was done periodically at 6, 9, 15, 21, and 28 days post-infection to evaluate different tests required. Whole blood was collected with heparin or ethylenediamine tetra-acetic acid as anticoagulant to help in the hematological studies such as red blood cells count (RBCs), white blood cells count, packed cell volume (PCV), and hemoglobin (Hb). Only marked increase in the total leuckocytic count was recorded while RBCs, PCV, and Hb were decreased in most of the results obtained. Total protein and globulin decreased while albumin and A/G ratio increased. Liver enzymes showing marked increase in aspartate aminotransferase and increase in alanine aminotransferase in dogs and rats denoting that liver has a role in the response to that infection. Kidney-function tests, urea, and creatinine showed slight increase at 6 days post-infection (d.p.i.). After preparation of different Ag (antigen) from different collected helminthes, the protein content of each was determined. The sera of infected animals were collected to find antibodies in their blood against the parasite using enzyme-linked immunosorbent assay and using crude heterophyid antigen collected from their intestines after scarification. The worms washed, homogenized, and then centrifuged to collect supernatant fluid as antigens. The results indicated that antibody starts to appear at 9 d.p.i. and increases till 21 and 28 d.p.i. and detection depends on antigen concentration.

  6. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    Science.gov (United States)

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  7. Present status of mechanical testing technology at the Research Hot Laboratory

    International Nuclear Information System (INIS)

    Kizaki, M.; Tobita, T.; Koya, T.; Kikuchi, T.

    1993-01-01

    Mechanical tests of irradiated metallic materials at the Research Hot Laboratory(RHL) have been carried out for 30 years to support material research in JAERI and to evaluate the irradiation integrity of pressure vessel steel in commercial power plant. Two tensile testing machines and one Charpy impact testing machine are available for the examinations. One of the tensile testing machines has 1000 kgf load capacity under the vacuum of ∼ 10 -7 torr at the temperature of 1300degC max.. The other one has 10 tonf load capacity, and is utilized for the multi-purpose tests such as tensile and compressive tests in air atmosphere at the temperature between -160 and 900degC. Examinations cover tensile test, bending test, J ic fracture toughness test, low cycle fatigue test and so on. Charpy impact testing machine with notched-bar specimen is instrumented with 30 kgf-m capacity in the temperature range of -140 - 240 degC. To support these mechanical tests in RHL, special jigs, devices and instruments have been developed. (author)

  8. Developing a competency framework for U.S. state food and feed testing laboratory personnel.

    Science.gov (United States)

    Kaml, Craig; Weiss, Christopher C; Dezendorf, Paul; Ishida, Maria; Rice, Daniel H; Klein, Ron; Salfinger, Yvonne

    2014-01-01

    A competency-based training curriculum framework for U.S. state food and feed testing laboratories personnel is being developed by the International Food Protection Training Institute (IFPTI) and three partners. The framework will help laboratories catalog existing training courses/modules, identify training gaps, inform training curricula, and create career-spanning professional development learning paths, ensuring consistent performance expectations and increasing confidence in shared test results. Ultimately, the framework will aid laboratories in meeting the requirements of ISO/IEC 17025 (2005) international accreditation and the U.S. Food Safety Modernization Act (U.S. Public Law 111-353). In collaboration with the Association of Food and Drug Officials, the Association of Public Health Laboratories, and the Association of American Feed Control Officials, IFPTI is carrying out the project in two phases. In 2013, an expert panel of seven subject matter experts developed competency and curriculum frameworks for five professional levels (entry, mid-level, expert, supervisor/manager, and senior administration) across four competency domains (technical, communication, programmatic, and leadership) including approximately 80 competencies. In 2014 the expert panel will elicit feedback from peers and finalize the framework.

  9. Phlebotomy and quality in the African laboratory

    Directory of Open Access Journals (Sweden)

    Henry A. Mbah

    2014-08-01

    Full Text Available Phlebotomy, the act of drawing blood through venepuncture, is one of the most common medical procedures in healthcare, as well as being a basis for diagnosis and treatment. A review of the available research has highlighted the dearth of information on the phlebotomy practice in Africa. Several studies elsewhere have shown that the pre-analytical phase (patient preparation, specimen collection and identification, transportation, preparation for analysis and storage is the most error-prone process in laboratory medicine. The validity of any laboratory test result hinges on specimen quality; thus, as the push for laboratory quality improvement in Africa gathers momentum, the practice of phlebotomy should be subjected to critical appraisal. This article offers several suggestions for the improvement of phlebotomy in Africa.

  10. FJ44 Turbofan Engine Test at NASA Glenn Research Center's Aero-Acoustic Propulsion Laboratory

    Science.gov (United States)

    Lauer, Joel T.; McAllister, Joseph; Loew, Raymond A.; Sutliff, Daniel L.; Harley, Thomas C.

    2009-01-01

    A Williams International FJ44-3A 3000-lb thrust class turbofan engine was tested in the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory. This report presents the test set-up and documents the test conditions. Farfield directivity, in-duct unsteady pressures, duct mode data, and phased-array data were taken and are reported separately.

  11. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean.

    Directory of Open Access Journals (Sweden)

    Alfonso Clavijo

    2017-04-01

    Full Text Available The direct fluorescent antibody test (DFA, is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC. Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies.

  12. Errors in clinical laboratories or errors in laboratory medicine?

    Science.gov (United States)

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  13. Tested Studies for Laboratory Teaching. Proceedings of the Workshop/Conference of the Association for Biology Laboratory Education (ABLE) (13th, Laramie, Wyoming, June 11-15, 1991). Volume 13.

    Science.gov (United States)

    Goldman, Corey A., Ed.

    The focus of the Association for Biology Laboratory Education (ABLE) is to improve the undergraduate biology laboratory experience by promoting the development and dissemination of interesting, innovative, and reliable laboratory exercises. This proceedings volume contains 10 papers: "Testing Issues of Foraging and Flocking Behavior" (C. C.…

  14. 21 CFR 212.60 - What requirements apply to the laboratories where I test components, in-process materials, and...

    Science.gov (United States)

    2010-04-01

    ... maintenance. Each laboratory must have and follow written procedures to ensure that equipment is routinely... 21 Food and Drugs 4 2010-04-01 2010-04-01 false What requirements apply to the laboratories where...) Laboratory Controls § 212.60 What requirements apply to the laboratories where I test components, in-process...

  15. Common signs and symptoms in hypothyroidism in central part of iran

    International Nuclear Information System (INIS)

    Jabbari, A.; Besharat, S.; Razavianzadeh, N.; Moetabar, M.

    2008-01-01

    This study was designed to evaluate the common signs and symptoms of hypothyroidism in persons with clinical diagnosis of hypothyroidism that was confirmed with laboratory tests. This descriptive cross-sectional study was done during 13 months in medical centers of Shahrood city, in central part of Iran. All cases with probable diagnosis of hypothyroidism based on the signs and symptoms, referred to health care services were included in the study. Radioimmunoassay tests and thyroid hormones evaluation were done. Demographic data and signs were recorded through interview. Data were entered in the computer and analyzed by SPSS software. Patients who completed questionnaires (n=50) were interviewed three times during this period. Female/male ratio was 6/1. The most common signs were cold intolerance (95%), weight gain and menorrhagia. The most common symptoms were edema (80%) and pallor (60%). The severe disease was seen in 4%. Mild type was the most common presentation of hypothyroidism (60%). The most common signs and symptoms of hypothyroidism in the central part of Iran (Shahrood city), that is one of the iodine deficient areas in Iran; were different from other studies. Socio-demographic and nutritional status, illiteracy level and personal self-care are among the probable causes. Unfortunately, concomitance of some of the signs and symptoms are not diagnostic for hypothyroidism. It seems that strong clinical suspicious and laboratory confirmation are the only reliable methods for hypothyroidism diagnosis. (author)

  16. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Science.gov (United States)

    2010-10-01

    ...'s procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND... meets the inspection and test procedures of the laboratory; and (3) Are accepted by the Commandant under...

  17. Quality management and accreditation in a mixed research and clinical hair testing analytical laboratory setting-a review.

    Science.gov (United States)

    Fulga, Netta

    2013-06-01

    Quality management and accreditation in the analytical laboratory setting are developing rapidly and becoming the standard worldwide. Quality management refers to all the activities used by organizations to ensure product or service consistency. Accreditation is a formal recognition by an authoritative regulatory body that a laboratory is competent to perform examinations and report results. The Motherisk Drug Testing Laboratory is licensed to operate at the Hospital for Sick Children in Toronto, Ontario. The laboratory performs toxicology tests of hair and meconium samples for research and clinical purposes. Most of the samples are involved in a chain of custody cases. Establishing a quality management system and achieving accreditation became mandatory by legislation for all Ontario clinical laboratories since 2003. The Ontario Laboratory Accreditation program is based on International Organization for Standardization 15189-Medical laboratories-Particular requirements for quality and competence, an international standard that has been adopted as a national standard in Canada. The implementation of a quality management system involves management commitment, planning and staff education, documentation of the system, validation of processes, and assessment against the requirements. The maintenance of a quality management system requires control and monitoring of the entire laboratory path of workflow. The process of transformation of a research/clinical laboratory into an accredited laboratory, and the benefits of maintaining an effective quality management system, are presented in this article.

  18. Feasibility of Combining Common Data Elements Across Studies to Test a Hypothesis.

    Science.gov (United States)

    Corwin, Elizabeth J; Moore, Shirley M; Plotsky, Andrea; Heitkemper, Margaret M; Dorsey, Susan G; Waldrop-Valverde, Drenna; Bailey, Donald E; Docherty, Sharron L; Whitney, Joanne D; Musil, Carol M; Dougherty, Cynthia M; McCloskey, Donna J; Austin, Joan K; Grady, Patricia A

    2017-05-01

    The purpose of this article is to describe the outcomes of a collaborative initiative to share data across five schools of nursing in order to evaluate the feasibility of collecting common data elements (CDEs) and developing a common data repository to test hypotheses of interest to nursing scientists. This initiative extended work already completed by the National Institute of Nursing Research CDE Working Group that successfully identified CDEs related to symptoms and self-management, with the goal of supporting more complex, reproducible, and patient-focused research. Two exemplars describing the group's efforts are presented. The first highlights a pilot study wherein data sets from various studies by the represented schools were collected retrospectively, and merging of the CDEs was attempted. The second exemplar describes the methods and results of an initiative at one school that utilized a prospective design for the collection and merging of CDEs. Methods for identifying a common symptom to be studied across schools and for collecting the data dictionaries for the related data elements are presented for the first exemplar. The processes for defining and comparing the concepts and acceptable values, and for evaluating the potential to combine and compare the data elements are also described. Presented next are the steps undertaken in the second exemplar to prospectively identify CDEs and establish the data dictionaries. Methods for common measurement and analysis strategies are included. Findings from the first exemplar indicated that without plans in place a priori to ensure the ability to combine and compare data from disparate sources, doing so retrospectively may not be possible, and as a result hypothesis testing across studies may be prohibited. Findings from the second exemplar, however, indicated that a plan developed prospectively to combine and compare data sets is feasible and conducive to merged hypothesis testing. Although challenges exist in

  19. FAMILIARISATION AND RELIABILITY OF SPRINT TEST INDICES DURING LABORATORY AND FIELD ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Andrew Galbraith

    2009-12-01

    Full Text Available The aim of the study was to assess the reliability of sprint performance in both field and laboratory conditions. Twenty-one male (mean ± s: 19 ± 1 years, 1.79 ± 0.07 m, 77.6 ± 7.1 kg and seventeen female team sport players (mean ± s: 21 ± 4 years, 1.68 ± 0. 07 m, 62.7 ± 4.7 kg performed a maximal 20-metre sprint running test on eight separate occasions. Four trials were conducted on a non-motorised treadmill in the laboratory; the other four were conducted outdoors on a hard-court training surface with time recorded by single-beam photocells. Trials were conducted in random order with no familiarisation prior to testing. There was a significant difference between times recorded during outdoor field trials (OFT and indoor laboratory trials (ILT using a non-motorised treadmill (3.47 ± 0.53 vs. 6.06 ±1.17s; p < 0.001. The coefficient of variation (CV for time was 2.55-4.22% for OFT and 5.1-7.2% for ILT. During ILT peak force (420.9 ± 87.7N, mean force (147.2 ± 24.7N, peak power (1376.8 ± 451.9W and mean power (514.8 ± 164.4W, and were measured. The CV for all ILT variables was highest during trial 1-2 comparison. The CV (95% confidence interval for the trial 3-4 comparison yielded: 9.4% (7.7-12. 1%, 7.9% (6.4-10.2%, 10.1% (8.2-13.1% and 6.2% (5.1-8.0% for PF, MF, PP and MP and respectively. The results indicate that reliable data can be derived for single maximal sprint measures, using fixed distance protocols. However, significant differences in time/speed over 20-m exist between field and laboratory conditions. This is primarily due to the frictional resistance in the non- motorised treadmill. Measures of force and power during ILT require at least 3 familiarisations to reduce variability in test scores

  20. Improving laboratory efficiencies to scale-up HIV viral load testing.

    Science.gov (United States)

    Alemnji, George; Onyebujoh, Philip; Nkengasong, John N

    2017-03-01

    Viral load measurement is a key indicator that determines patients' response to treatment and risk for disease progression. Efforts are ongoing in different countries to scale-up access to viral load testing to meet the Joint United Nations Programme on HIV and AIDS target of achieving 90% viral suppression among HIV-infected patients receiving antiretroviral therapy. However, the impact of these initiatives may be challenged by increased inefficiencies along the viral load testing spectrum. This will translate to increased costs and ineffectiveness of scale-up approaches. This review describes different parameters that could be addressed across the viral load testing spectrum aimed at improving efficiencies and utilizing test results for patient management. Though progress is being made in some countries to scale-up viral load, many others still face numerous challenges that may affect scale-up efficiencies: weak demand creation, ineffective supply chain management systems; poor specimen referral systems; inadequate data and quality management systems; and weak laboratory-clinical interface leading to diminished uptake of test results. In scaling up access to viral load testing, there should be a renewed focus to address efficiencies across the entire spectrum, including factors related to access, uptake, and impact of test results.

  1. Stress-strain relation of bentonite at undrained shear. Laboratory tests to investigate the influence of material composition and test technique

    Energy Technology Data Exchange (ETDEWEB)

    Dueck, Ann; Boergesson, Lennart; Johannesson, Lars-Erik (Clay Technology AB, Lund (Sweden))

    2010-12-15

    This report describes a laboratory study conducted to update the material model of the buffer material used in the analyses of the effect of a rock shear through a deposition hole. The study considers some new conditions and is especially focused on the reference case with MX-80Ca developed for SR-Site (MX-80 ion exchanged to Ca). The material model is based on relations between density, swelling pressure, shear strength and rate of strain. The reference model is described by Boergesson et al. (2010). The laboratory study is focused on undrained stress-strain-strength properties, which have been studied mainly by conducting triaxial tests and unconfined compression tests. The test results are compared to the earlier measurements and models which show that the new results fit very well into the general picture and models. For the new conditions suitable values of constants included in the model are proposed

  2. Stress-strain relation of bentonite at undrained shear. Laboratory tests to investigate the influence of material composition and test technique

    International Nuclear Information System (INIS)

    Dueck, Ann; Boergesson, Lennart; Johannesson, Lars-Erik

    2010-12-01

    This report describes a laboratory study conducted to update the material model of the buffer material used in the analyses of the effect of a rock shear through a deposition hole. The study considers some new conditions and is especially focused on the reference case with MX-80Ca developed for SR-Site (MX-80 ion exchanged to Ca). The material model is based on relations between density, swelling pressure, shear strength and rate of strain. The reference model is described by Boergesson et al. (2010). The laboratory study is focused on undrained stress-strain-strength properties, which have been studied mainly by conducting triaxial tests and unconfined compression tests. The test results are compared to the earlier measurements and models which show that the new results fit very well into the general picture and models. For the new conditions suitable values of constants included in the model are proposed

  3. Common pitfalls in statistical analysis: Understanding the properties of diagnostic tests - Part 1.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    In this article in our series on common pitfalls in statistical analysis, we look at some of the attributes of diagnostic tests (i.e., tests which are used to determine whether an individual does or does not have disease). The next article in this series will focus on further issues related to diagnostic tests.

  4. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    Science.gov (United States)

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  5. Bioassay Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Bioassay Laboratory is an accredited laboratory capable of conducting standardized and innovative environmental testing in the area of aquatic ecotoxicology. The...

  6. Organization of Proficiency Testing for Dairy Laboratories in Croatia, Bosnia and Herzegovina and Macedonia in Order to Improve Quality Assurance

    Directory of Open Access Journals (Sweden)

    Nataša Mikulec

    2009-06-01

    Full Text Available Participation in proficiency testing is not only an obligation for all analytical laboratories which tend to be credible, but also an opportunity to check how the results agree with the reference or assign value. The Reference Laboratory for Milk and Dairy Products of the Dairy Science Department, Faculty of Agriculture University of Zagreb, is itself incorporated in the proficiency testing organized by dairy laboratories from Germany, Italy, France, Switzerland and Slovenia. The aim is to find out its own accuracy and reliability in particular milk and dairy products analyses. On the basis of seven years experience of participating in proficiency testing, five years ago the Reference Laboratory started organizing its own proficiency testing for dairy laboratories in Croatia, Bosnia and Herzegovina and Macedonia for milk components such as milk fat, protein, lactose and somatic cells count. The results of the analyses have been statistically analyzed and, on the basis of Z-score, the successful measurements have been estimated. The aim of this paper is to demonstrate the organisation and data processing of proficiency testing for milk fat, protein, lactose and somatic cells count in milk for the involved dairy laboratories.

  7. The Laboratory Diagnosis of Haemophilus ducreyi

    Directory of Open Access Journals (Sweden)

    Michelle Alfa

    2005-01-01

    Full Text Available Chancroid is a sexually transmitted infection caused by Haemophilus ducreyi. This fastidious, Gram-negative coccobacilli dies rapidly outside the human host, making diagnostic testing using culture methods difficult. This genital ulcer infection is not common in Canada and, therefore, can often be misdiagnosed. The objective of the present paper is to provide practical approaches for the diagnosis of chancroid in Canadian patients where the prevalence of this infection is low. Issues related to sample collection, sample transport and available diagnostic tests are reviewed, and several alternative approaches are outlined. Although antigen detection, serology and genetic amplification methods have all been reported for H ducreyi, none are commercially available. Culture is still the primary method available to most laboratories. However, the special media necessary for direct bedside inoculation is often not available; therefore, communication with the diagnostic laboratory and rapid specimen transport are essential when chancroid is suspected

  8. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    Energy Technology Data Exchange (ETDEWEB)

    Hattar, Khalid Mikhiel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Ion Beam Lab.; Olszewska-Wasiolek, Maryla Aleksandra [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Gamma Irradiation Facility

    2017-01-01

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route and in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.

  9. How Reliable Is Laboratory Testing?

    Science.gov (United States)

    ... type of container and mixed with the right preservative, when appropriate. The laboratory staff who collect samples ... avoid known interferences. You may be instructed to fast or avoid certain foods or activities. Carefully follow these instructions to prepare ...

  10. Acoustic testing and modeling: an advanced undergraduate laboratory.

    Science.gov (United States)

    Russell, Daniel A; Ludwigsen, Daniel O

    2012-03-01

    This paper describes an advanced laboratory course in acoustics, specifically targeted for students with an interest in engineering applications at a school with a strongly integrated industrial co-op program. The laboratory course is developed around a three-pronged approach to problem solving that combines and integrates theoretical models, computational models, and experimental data. The course is structured around modules that begin with fundamental concepts and build laboratory skills and expand the knowledge base toward a final project. Students keep a detailed laboratory notebook, write research papers in teams, and must pass laboratory certification exams. This paper describes the course layout and philosophy and shares personal experience from both faculty and student perspectives. © 2012 Acoustical Society of America

  11. Results of single borehole hydraulic tests in the Mizunami Underground Research Laboratory project. FY 2012 - FY 2015

    International Nuclear Information System (INIS)

    Onoe, Hironori; Takeuchi, Ryuji

    2016-11-01

    This report summarize the results of the single borehole hydraulic tests of 151 sections carried out at the -300 m Stage and the -500 m Stage of the Mizunami Underground Research Laboratory from FY 2012 to FY 2015. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical methods used are presented in this report. Furthermore, the previous results of the single borehole hydraulic tests carried out in the Regional Hydrogeological Study Project and the Mizunami Underground Research Laboratory Project before FY 2012 are also summarized in this report. (author)

  12. Interventions to Improve Follow-Up of Laboratory Test Results Pending at Discharge: A Systematic Review.

    Science.gov (United States)

    Whitehead, Nedra S; Williams, Laurina; Meleth, Sreelatha; Kennedy, Sara; Epner, Paul; Singh, Hardeep; Wooldridge, Kathleene; Dalal, Anuj K; Walz, Stacy E; Lorey, Tom; Graber, Mark L

    2018-02-28

    Failure to follow up test results pending at discharge (TPAD) from hospitals or emergency departments is a major patient safety concern. The purpose of this review is to systematically evaluate the effectiveness of interventions to improve follow-up of laboratory TPAD. We conducted literature searches in PubMed, CINAHL, Cochrane, and EMBASE using search terms for relevant health care settings, transition of patient care, laboratory tests, communication, and pending or missed tests. We solicited unpublished studies from the clinical laboratory community and excluded articles that did not address transitions between settings, did not include an intervention, or were not related to laboratory TPAD. We also excluded letters, editorials, commentaries, abstracts, case reports, and case series. Of the 9,592 abstracts retrieved, 8 met the inclusion criteria and reported the successful communication of TPAD. A team member abstracted predetermined data elements from each study, and a senior scientist reviewed the abstraction. Two experienced reviewers independently appraised the quality of each study using published LMBP™ A-6 scoring criteria. We assessed the body of evidence using the A-6 methodology, and the evidence suggested that electronic tools or one-on-one education increased documentation of pending tests in discharge summaries. We also found that automated notifications improved awareness of TPAD. The interventions were supported by suggestive evidence; this type of evidence is below the level of evidence required for LMBP™ recommendations. We encourage additional research into the impact of these interventions on key processes and health outcomes. © 2018 Society of Hospital Medicine.

  13. Tests for oil/dispersant toxicity: In situ laboratory assays

    International Nuclear Information System (INIS)

    Wright, D.A.; Coelho, G.M.; Aurand, D.V.

    1995-01-01

    As part of its readiness program in oil spill response, the Marine Pollution Control Unit (MPCU), Department of Transport, U.K. conducts annual field trials in the North Sea, approximately 30 nautical miles from the southeast coast of England. The trials take the form of controlled releases of crude oil or Medium Fuel/Gas Oil mix (MFO), with and without the application of Corexit 9527 dispersant. In 1994 and 1995 the authors conducted a series of in situ toxicity bioassays in association with these spills with included 48h LC50 tests for turbot (Scophthalmus maximus) and oyster (Crassostrea gigas) larvae, a 48 h oyster (C. gigas) embryonic development test and two full life-cycle assays using the copepods Acartia tonsa and Tisbe battagliai. Tests were also conducted in the Chesapeake Bay laboratory using estuarine species including the copepod Eurytemora affinis and the inland silverside Menidia beryllina. Here, the authors report on the results of these assays, together with 1996 in situ toxicity data resulting from Norwegian field trials in the northern North Sea

  14. Sexually transmitted infections in women: A correlation of clinical and laboratory diagnosis in cases of vaginal discharge syndrome

    Directory of Open Access Journals (Sweden)

    Vidyalaxmi Chauhan

    2014-01-01

    Full Text Available Aims: This study compares the clinical and laboratory diagnosis of vaginal discharge syndrome. Settings and Design: This cross-sectional study was carried out at the gynaecology outpatient department of a tertiary care hospital in Gujarat, India. Material and Methods: Total of 180 females diagnosed as vaginal discharge or cervicitis based on syndromic approach and were recruited for the study. Their clinical profile was noted and they were investigated for bacterial vaginosis, trichomoniasis, candidiasis, gonorrhoea and chlamydia infection. Results: Lower abdominal pain (35% followed by burning micturition (23.9% were the common associated complaints. Bacterial vaginosis was the most common clinical diagnosis, while trichomoniasis was least common. Upon laboratory investigation, 35.6% of cases of vaginal discharge and 12% of cases of cervicitis tested positive. Percentage of cases confirmed by laboratory investigation was 50, 27.8 and 41.7 for bacterial vaginosis, trichomoniasis and candidiasis respectively. Conclusion: Among all the females diagnosed as vaginal discharge syndrome, a very small percentage actually turned out to be positive upon laboratory testing.

  15. Emergency Response Proficiency Test for Japanese Laboratories: Determination of Selected Radionuclides in Water, Soil, Vegetation and Aerosol Filters

    International Nuclear Information System (INIS)

    2013-01-01

    Reliable determination of natural and artificial radionuclides in environmental samples is necessary for compliance with radiation protection and environmental regulations. The IAEA assists Member State laboratories in maintaining and improving their readiness in this regard by producing reference materials, by developing standardized analytical methods, and by conducting interlaboratory comparisons and proficiency tests as tools for quality control. To fulfil this obligation and ensure a reliable, rapid and consistent worldwide response, the IAEA Terrestrial Environment Laboratory in Seibersdorf, Austria, organizes interlaboratory comparisons and proficiency tests. In addition, the IAEA coordinates the worldwide network of Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA). After the accident at the Fukushima Daiichi nuclear power plant in March 2011, Japan requested the IAEA to organize an emergency response proficiency test for Japanese laboratories with the aim of assessing their capacity to rapidly and accurately measure radionuclides in environmental samples. The IAEA responded to the request by assembling a special sample set covering the main environmental samples and radionuclides of interest in the case of a nuclear emergency situation. Water, soil, vegetation and aerosol filter samples were made available to Japanese laboratories for analysis by gamma ray spectrometry. This report presents the results of the IAEA-TEL-2011-08 emergency response proficiency test for Japanese laboratories on the determination of selected radionuclides in water, soil, vegetation and aerosol filters. The report includes descriptions of the methodologies and data evaluation approach used, as well as summary evaluations of each radionuclide and individual evaluation reports of each laboratory. This proficiency test was designed to identify analytical problems and to support Member State laboratories in their efforts to improve the quality of

  16. Laboratory Assays in Evaluation of Lynch Syndrome in Patients with Endometrial Carcinoma.

    Science.gov (United States)

    Djordjevic, Bojana; Broaddus, Russell R

    2016-06-01

    This article reviews the main tissue testing modalities for Lynch Syndrome in the pathology laboratory, such as immunohistochemistry and PCR based analyses, and discusses their routine application, interpretation pitfalls, and troubleshooting of common technical performance issues. Discrepancies between laboratory and genetic testing may arise, and are examined in the context of the complexity of molecular abnormalities associated with Lynch Syndrome. The merits of targeted versus universal screening in a changing healthcare climate are addressed. In the absence of comprehensive screening programs, specific tumor topography and histological features that may prompt pathologist-initiated molecular tumor testing are outlined. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project "Laboratory Errors and Patient Safety".

    Science.gov (United States)

    Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario

    2011-05-01

    The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.

  18. Laboratory Evaluation of In Situ Chemical Oxidation for Groundwater Remediation, Test Area North, Operable Unit 1-07B, Idaho National Engineering and Environmental Laboratory, Volume Three - Appendix F

    Energy Technology Data Exchange (ETDEWEB)

    Cline, S.R.; Denton, D.L.; Giaquinto, J.M.; McCracken, M.K.; Starr, R.C.

    1999-04-01

    This appendix supports the results and discussion of the laboratory work performed to evaluate the feasibility of in situ chemical oxidation for Idaho National Environmental and Engineering Laboratory's (INEEL) Test Area North (TAN) which is contained in ORNL/TM-13711/V1. This volume contains Appendix F. Appendix F is essentially a photocopy of the ORNL researchers' laboratory notebooks from the Environmental Sciences Division (ESD) and the Radioactive Materials Analytical Laboratory (RMAL).

  19. Advantages and limitations of anticipating laboratory test results from regression- and tree-based rules derived from electronic health-record data.

    Directory of Open Access Journals (Sweden)

    Fahim Mohammad

    Full Text Available Laboratory testing is the single highest-volume medical activity, making it useful to ask how well one can anticipate whether a given test result will be high, low, or within the reference interval ("normal". We analyzed 10 years of electronic health records--a total of 69.4 million blood tests--to see how well standard rule-mining techniques can anticipate test results based on patient age and gender, recent diagnoses, and recent laboratory test results. We evaluated rules according to their positive and negative predictive value (PPV and NPV and area under the receiver-operator characteristic curve (ROC AUCs. Using a stringent cutoff of PPV and/or NPV≥0.95, standard techniques yield few rules for sendout tests but several for in-house tests, mostly for repeat laboratory tests that are part of the complete blood count and basic metabolic panel. Most rules were clinically and pathophysiologically plausible, and several seemed clinically useful for informing pre-test probability of a given result. But overall, rules were unlikely to be able to function as a general substitute for actually ordering a test. Improving laboratory utilization will likely require different input data and/or alternative methods.

  20. Advantages and limitations of anticipating laboratory test results from regression- and tree-based rules derived from electronic health-record data.

    Science.gov (United States)

    Mohammad, Fahim; Theisen-Toupal, Jesse C; Arnaout, Ramy

    2014-01-01

    Laboratory testing is the single highest-volume medical activity, making it useful to ask how well one can anticipate whether a given test result will be high, low, or within the reference interval ("normal"). We analyzed 10 years of electronic health records--a total of 69.4 million blood tests--to see how well standard rule-mining techniques can anticipate test results based on patient age and gender, recent diagnoses, and recent laboratory test results. We evaluated rules according to their positive and negative predictive value (PPV and NPV) and area under the receiver-operator characteristic curve (ROC AUCs). Using a stringent cutoff of PPV and/or NPV≥0.95, standard techniques yield few rules for sendout tests but several for in-house tests, mostly for repeat laboratory tests that are part of the complete blood count and basic metabolic panel. Most rules were clinically and pathophysiologically plausible, and several seemed clinically useful for informing pre-test probability of a given result. But overall, rules were unlikely to be able to function as a general substitute for actually ordering a test. Improving laboratory utilization will likely require different input data and/or alternative methods.

  1. Laboratory Performance Evaluation of High Modulus Asphalt Concrete Modified with Different Additives

    Directory of Open Access Journals (Sweden)

    Peng Li

    2017-01-01

    Full Text Available The objective of this study is to evaluate comprehensive performance of high modulus asphalt concrete (HMAC and propose common values for establishing evaluation system. Three gradations with different modifiers were conducted to study the high and low temperature performance, shearing behavior, and water stability. The laboratory tests for HMAC included static and dynamic modulus tests, rutting test, uniaxial penetration test, bending test, and immersion Marshall test. Dynamic modulus test results showed that modifier can improve the static modulus and the improvements were remarkable at higher temperature. Moreover, modulus of HMAC-20 was better than those of HMAC-16 and HMAC-25. The results of performance test indicated that HMAC has good performance to resist high temperature rutting, and the resistances of the HMAC-20 and HMAC-25 against rutting were better than that of HMAC-16. Then, the common values of dynamic stability were recommended. Furthermore, common values of HMAC performance were established based on pavement performance tests.

  2. Performance of IPEN/CNEN-SP Neutron Activation Analysis Laboratory for microelement determinations in proficiency testing

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Saiki, Mitiko; Souza, Gilberto B. de; Nogueira, Ana Rita A.

    2009-01-01

    The performance of Neutron Activation Laboratory, IPEN - CNEN/SP, was evaluated for the Ca, Fe, K, Mn, Na and Zn determinations in animal feed samples for ruminants through a proficiency test (PT) program. This PT program is organized by EMBRAPA Cattle Southeast to evaluate laboratories that analyze animal feed samples. Considering the fractions of satisfactory z-scores (%) of evaluated analytes to determine the laboratories performance, the general performance indicator obtained by IPEN - CNEN/SP ranged from 90 to 95% of the satisfactory results during the period of participation in the evaluation, four years. (author)

  3. Point of care testing of fecal calprotectin as a substitute for routine laboratory analysis

    DEFF Research Database (Denmark)

    Hejl, Julie; Theede, Klaus; Møllgren, Brian

    2018-01-01

    Objectives Fecal calprotectin (FC) is widely used to monitor the activity of inflammatory bowel disease (IBD) and to tailor medical treatment to disease activity. Laboratory testing of fecal samples may have a turnaround time of 1–2 weeks, whereas FC home testing allows results within hours...... and thus enables a rapid response to clinical deterioration. Design and methods Fifty-five stool samples were analyzed by the IBDoc® Calprotectin Home Testing kit and the BÜHLMANN fCAL® turbo assay on a Roche Cobas 6000 c501. The correlation between the assays was assessed using Spearman's Rho correlation...... coefficient and the intermediate imprecision of both assays was calculated. Results We found a strong correlation coefficient of 0.887 between FC measured on IBDoc® and the laboratory assay BÜHLMANN fCAL® turbo. The coefficients of variation (CVs) at three different FC levels were in the range 2...

  4. NNWSI waste form testing at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.; Abrajano, T.A. Jr.; Ebert, W.L.; Mazer, J.J.

    1988-11-01

    The Nevada Nuclear Waste Storage Investigation (NNWSI) Project is investigating the tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. As part of the waste package development portion of this project, experiments are being performed by the Chemical Technology Division of Argonne National Laboratory to study the behavior of the waste form under anticipated repository conditions. These experiments include the development and performance of a test to measure waste form behavior in unsaturated conditions and the performance of experiments designed to study the behavior of waste package components in an irradiated environment. Previous reports document developments in these areas through 1986. This report summarizes progress during the period January--June 1987, 19 refs., 17 figs., 20 tabs

  5. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    Science.gov (United States)

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  6. [Statistical approach to evaluate the occurrence of out-of acceptable ranges and accuracy for antimicrobial susceptibility tests in inter-laboratory quality control program].

    Science.gov (United States)

    Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa

    2013-03-01

    To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.

  7. Influenza outbreak during Sydney World Youth Day 2008: the utility of laboratory testing and case definitions on mass gathering outbreak containment.

    Directory of Open Access Journals (Sweden)

    Sebastiaan J van Hal

    Full Text Available BACKGROUND: Influenza causes annual epidemics and often results in extensive outbreaks in closed communities. To minimize transmission, a range of interventions have been suggested. For these to be effective, an accurate and timely diagnosis of influenza is required. This is confirmed by a positive laboratory test result in an individual whose symptoms are consistent with a predefined clinical case definition. However, the utility of these clinical case definitions and laboratory testing in mass gathering outbreaks remains unknown. METHODS AND RESULTS: An influenza outbreak was identified during World Youth Day 2008 in Sydney. From the data collected on pilgrims presenting to a single clinic, a Markov model was developed and validated against the actual epidemic curve. Simulations were performed to examine the utility of different clinical case definitions and laboratory testing strategies for containment of influenza outbreaks. Clinical case definitions were found to have the greatest impact on averting further cases with no added benefit when combined with any laboratory test. Although nucleic acid testing (NAT demonstrated higher utility than indirect immunofluorescence antigen or on-site point-of-care testing, this effect was lost when laboratory NAT turnaround times was included. The main benefit of laboratory confirmation was limited to identification of true influenza cases amenable to interventions such as antiviral therapy. CONCLUSIONS: Continuous re-evaluation of case definitions and laboratory testing strategies are essential for effective management of influenza outbreaks during mass gatherings.

  8. Federal laboratory nondestructive testing research and development applicable to industry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.A.; Moore, N.L.

    1987-02-01

    This document presents the results of a survey of nondestructive testing (NDT) and related sensor technology research and development (R and D) at selected federal laboratories. Objective was to identify and characterize NDT activities that could be applied to improving energy efficiency and overall productivity in US manufacturing. Numerous federally supported R and D programs were identified in areas such as acoustic emissions, eddy current, radiography, computer tomography and ultrasonics. A Preliminary Findings Report was sent to industry representatives, which generated considerable interest.

  9. Are effects of common ragwort in the Ames test caused by pyrrolizidine alkaloids?

    Science.gov (United States)

    Bovee, Toine F H; Helsdingen, Richard J R; Hoogenboom, Ron L A P; de Nijs, Monique W C M; Liu, Xiaojie; Vrieling, Klaas; Klinkhamer, Peter G L; Peijnenburg, Ad A C M; Mulder, Patrick P J

    2015-08-01

    It has previously been demonstrated by others that acetone extracts of Senecio jacobaea (syn. Jacobaea vulgaris, common or tansy ragwort) test positive in the Salmonella/microsome mutagenicity test (Ames test). Pyrrolizidine alkaloids (PAs) are thought to be responsible for these mutagenic effects. However, it was also observed that the major PA present in common ragwort, jacobine, produced a negative response (with and without the addition of rat liver S9) in Salmonella test strains TA98, TA100, TA1535 and TA1537. To investigate which compounds in the plant extracts were responsible for the positive outcome, the present study investigated the contents and mutagenic effects of methanol and acetone extracts prepared from dried ground S. jacobaea and Senecio inaequidens (narrow-leafed ragwort). Subsequently, a fractionation approach was set up in combination with LC-MS/MS analysis of the fractions. It was shown that the positive Ames test outcomes of S. jacobaea extracts are unlikely to be caused by PAs, but rather by the flavonoid quercetin. This study also demonstrates the importance of identifying compounds responsible for positive test results in bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A Novel Approach to Improving Utilization of Laboratory Testing.

    Science.gov (United States)

    Zhou, Yaolin; Procop, Gary W; Riley, Jacquelyn D

    2018-02-01

    - The incorporation of best practice guidelines into one's institution is a challenging goal of utilization management, and the successful adoption of such guidelines depends on institutional context. Laboratorians who have access to key clinical data are well positioned to understand existing local practices and promote more appropriate laboratory testing. - To apply a novel approach to utilization management by reviewing international clinical guidelines and current institutional practices to create a reliable mechanism to improve detection and reduce unnecessary tests in our patient population. - We targeted a frequently ordered genetic test for HFE-related hereditary hemochromatosis, a disorder of low penetrance. After reviewing international practice guidelines, we evaluated 918 HFE tests and found that all patients with new diagnoses had transferrin saturation levels that were significantly higher than those of patients with nonrisk genotypes (72% versus 42%; P < .001). - Our "one-button" order that restricts HFE genetic tests to patients with transferrin saturation greater than 45% is consistent with published practice guidelines and detected 100% of new patients with HFE-related hereditary hemochromatosis. - Our proposed algorithm differs from previously published approaches in that it incorporates both clinical practice guidelines and local physician practices, yet requires no additional hands-on effort from pathologists or clinicians. This novel approach to utilization management embraces the role of pathologists as leaders in promoting high-quality patient care in local health care systems.

  11. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    International Nuclear Information System (INIS)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J.

    2010-02-01

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  12. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    Energy Technology Data Exchange (ETDEWEB)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J. (British Geological Survey (United Kingdom))

    2010-02-15

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  13. Test-enhanced learning: the potential for testing to promote greater learning in undergraduate science courses.

    Science.gov (United States)

    Brame, Cynthia J; Biel, Rachel

    2015-01-01

    Testing within the science classroom is commonly used for both formative and summative assessment purposes to let the student and the instructor gauge progress toward learning goals. Research within cognitive science suggests, however, that testing can also be a learning event. We present summaries of studies that suggest that repeated retrieval can enhance long-term learning in a laboratory setting; various testing formats can promote learning; feedback enhances the benefits of testing; testing can potentiate further study; and benefits of testing are not limited to rote memory. Most of these studies were performed in a laboratory environment, so we also present summaries of experiments suggesting that the benefits of testing can extend to the classroom. Finally, we suggest opportunities that these observations raise for the classroom and for further research. © 2015 C. J. Brame and R. Biel. CBE—Life Sciences Education © 2015 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  14. Laboratory creep and mechanical tests on salt data report (1975-1996): Waste Isolation Pilot Plant (WIPP) thermal/structural interactions program

    Energy Technology Data Exchange (ETDEWEB)

    Mellegard, K.D. [RE/SPEC Inc., Rapid City, SD (United States); Munson, D.E. [Sandia National Labs., Albuquerque, NM (United States)

    1997-02-01

    The Waste Isolation Pilot Plant (WIPP), a facility located in a bedded salt formation in Carlsbad, New Mexico, is being used by the U.S. Department of Energy to demonstrate the technology for safe handling and disposal of transuranic wastes produced by defense activities in the United States. In support of that demonstration, mechanical tests on salt were conducted in the laboratory to characterize material behavior at the stresses and temperatures expected for a nuclear waste repository. Many of those laboratory test programs have been carried out in the RE/SPEC Inc. rock mechanics laboratory in Rapid City, South Dakota; the first program being authorized in 1975 followed by additional testing programs that continue to the present. All of the WIPP laboratory data generated on salt at RE/SPEC Inc. over the last 20 years is presented in this data report. A variety of test procedures were used in performance of the work including quasi-static triaxial compression tests, constant stress (creep) tests, damage recovery tests, and multiaxial creep tests. The detailed data is presented in individual plots for each specimen tested. Typically, the controlled test conditions applied to each specimen are presented in a plot followed by additional plots of the measured specimen response. Extensive tables are included to summarize the tests that were performed. Both the tables and the plots contain cross-references to the technical reports where the data were originally reported. Also included are general descriptions of laboratory facilities, equipment, and procedures used to perform the work.

  15. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    Science.gov (United States)

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  16. Results of single borehole hydraulic testing in the Mizunami Underground Research Laboratory project. Phase 2

    International Nuclear Information System (INIS)

    Daimaru, Shuji; Takeuchi, Ryuji; Onoe, Hironori; Saegusa, Hiromitsu

    2012-09-01

    This report summarize the results of the single borehole hydraulic tests of 79 sections conducted as part of the Construction phase (Phase 2) in the Mizunami Underground Research Laboratory (MIU) Project. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical method used are presented in this report. (author)

  17. Cement/bentonite interaction. Results from 16 month laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, O. [Clay Technology AB, Lund (Sweden)

    1997-12-01

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites 5 refs, 48 figs, 11 tabs

  18. Managing the Mars Science Laboratory Thermal Vacuum Test for Safety and Success

    Science.gov (United States)

    Evans, Jordan P.

    2010-01-01

    The Mars Science Laboratory is a NASA/JPL mission to send the next generation of rover to Mars. Originally slated for launch in 2009, development problems led to a delay in the project until the next launch opportunity in 2011. Amidst the delay process, the Launch/Cruise Solar Thermal Vacuum Test was undertaken as risk reduction for the project. With varying maturity and capabilities of the flight and ground systems, undertaking the test in a safe manner presented many challenges. This paper describes the technical and management challenges and the actions undertaken that led to the ultimate safe and successful execution of the test.

  19. Laboratory and pilot field-scale testing of surfactants for environmental restoration of chlorinated solvent DNAPLs

    International Nuclear Information System (INIS)

    Jackson, R.E.; Fountain, J.C.

    1994-01-01

    This project is composed of two phases and has the objective of demonstrating surfactant-enhanced aquifer remediation (SEAR) as a practical remediation technology at DOE sites with ground water contaminated by dense, non-aqueous phase liquids (DNAPLs), in particular, chlorinated solvents. The first phase of this project, Laboratory and Pilot Field Scale Testing, which is the subject of the work so far, involves (1) laboratory experiments to examine the solubilization of multiple component DNAPLs, e.g., solvents such as perchloroethylene (PCE) and trichloroethylene (TCE), by dilute surfactant solutions, and (2) a field test to demonstrate SEAR technology on a small scale and in an existing well

  20. 75 FR 34463 - Oversight of Laboratory Developed Tests; Public Meeting; Request for Comments

    Science.gov (United States)

    2010-06-17

    ... patient population. In addition, the components of traditional LDTs were regulated individually by FDA as... field creates a competitive disadvantage and potential disincentive to innovation by other manufacturers...) Challenges for Laboratories, (3) Direct to Consumer Marketing of Testing, and (4) Education and Outreach...

  1. Quality of Liver and Kidney Function Tests among Public Medical Laboratories in Western Region of Amhara National Regional State of Ethiopia.

    Science.gov (United States)

    Teka, Abaynesh; Kibatu, Girma

    2012-03-01

    Medical laboratories play essential roles in measurements of substances in body fluids for the purpose of diagnosis, treatment, prevention, and for greater understanding of the disease process. Thus, data generated from have to be reliable for which strict quality control, management and assurance are maintained. The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from February to March, 2011. Each participant was requested to measure six specimens for six chemistry tests from two control samples. Three hundred twenty four test results to be reported from all participant laboratories, if all measurements can be made, were designed to be collected and statistically evaluated. None of the study subject laboratories could deliver all the six tests for estimation of both liver and renal functions simultaneously during the study period. Only 213 values from the expected 324 values were reported and about 65 % of the 213 values reported fell outside of the allowable limits of errors for the chemistry tests of the control specimen used. This study finding showed that there were lack of accuracy and precision in chemistry measurements. A regular survey on medical laboratories should be conducted questioning the accuracy and precision of their analyses in order to sustain improvements in the quality of services provided by participating laboratories for the benefit of patients. Laboratory Quality Management Systems appreciate the need for regular quality control and quality assessment schemes in medical laboratories.

  2. PIG's Speed Estimated with Pressure Transducers and Hall Effect Sensor: An Industrial Application of Sensors to Validate a Testing Laboratory.

    Science.gov (United States)

    Lima, Gustavo F; Freitas, Victor C G; Araújo, Renan P; Maitelli, André L; Salazar, Andrés O

    2017-09-15

    The pipeline inspection using a device called Pipeline Inspection Gauge (PIG) is safe and reliable when the PIG is at low speeds during inspection. We built a Testing Laboratory, containing a testing loop and supervisory system to study speed control techniques for PIGs. The objective of this work is to present and validate the Testing Laboratory, which will allow development of a speed controller for PIGs and solve an existing problem in the oil industry. The experimental methodology used throughout the project is also presented. We installed pressure transducers on pipeline outer walls to detect the PIG's movement and, with data from supervisory, calculated an average speed of 0.43 m/s. At the same time, the electronic board inside the PIG received data from odometer and calculated an average speed of 0.45 m/s. We found an error of 4.44%, which is experimentally acceptable. The results showed that it is possible to successfully build a Testing Laboratory to detect the PIG's passage and estimate its speed. The validation of the Testing Laboratory using data from the odometer and its auxiliary electronic was very successful. Lastly, we hope to develop more research in the oil industry area using this Testing Laboratory.

  3. Spontaneous common bile duct perforation—A rare clinical entity

    Directory of Open Access Journals (Sweden)

    Melissa Amberger

    Full Text Available Introduction: Spontaneous common bile duct perforation is an uncommon clinical entity in both adults and children. Few case reports have been published since the first clinical description in 1882. Our work has been reported in line with SCARE criteria. Presentation of case: Herein, we describe the case of a 28 year-old female who suffered spontaneous common bile duct perforation while admitted for choledocholithiasis. Discussion: The perforation occurred while in-hospital, and extensive imaging and laboratory tests characterized the disease in detail. To our knowledge, this is the first report of spontaneous common bile duct perforation witnessed from pre-perforation through definitive management. Conclusion: Physicians and Surgeons should seek out this uncommon diagnosis in the patient with suspected Choledocholithiasis who suddenly become peritoneal on physical exam so that definitive care can be expedited. Keywords: Common bile duct, Biliary peritonitis, Choledocholithiasis

  4. Analytic laboratory performance of a point of care urine culture kit for diagnosis and antibiotic susceptibility testing.

    Science.gov (United States)

    Bongard, E; Frimodt-Møller, N; Gal, M; Wootton, M; Howe, R; Francis, N; Goossens, H; Butler, C C

    2015-10-01

    Currently available point-of-care (POC) diagnostic tests for managing urinary tract infections (UTIs) in general practice are limited by poor performance characteristics, and laboratory culture generally provides results only after a few days. This laboratory evaluation compared the analytic performance of the POC UK Flexicult(™) (Statens Serum Institut) (SSI) urinary kit for quantification, identification and antibiotic susceptibility testing and routine UK National Health Service (NHS) urine processing to an advanced urine culture method. Two hundred urine samples routinely submitted to the Public Health Wales Microbiology Laboratory were divided and: (1) analysed by routine NHS microbiological tests as per local laboratory standard operating procedures, (2) inoculated onto the UK Flexicult(™) SSI urinary kit and (3) spiral plated onto Colorex Orientation UTI medium (E&O Laboratories Ltd). The results were evaluated between the NHS and Flexicult(™ )methods, and discordant results were compared to the spiral plating method. The UK Flexicult(™) SSI urinary kit was compared to routine NHS culture for identification of a pure or predominant uropathogen at ≥ 10(5) cfu/mL, with a positive discordancy rate of 13.5% and a negative discordancy rate of 3%. The sensitivity and specificity were 86.7% [95% confidence interval (CI) 73.8-93.7] and 82.6% (95% CI 75.8-87.7), respectively. The UK Flexicult(™) SSI urinary kit was comparable to routine NHS urine processing in identifying microbiologically positive UTIs in this laboratory evaluation. However, the number of false-positive samples could lead to over-prescribing of antibiotics in clinical practice. The Flexicult(™) SSI kit could be useful as a POC test for UTIs in primary care but further pragmatic evaluations are necessary.

  5. Educational digital resource for data analysis of Civil Engineering laboratory tests

    OpenAIRE

    Gustavo Henrique Nalon; Paulo Sergio de Almeida Barbosa; Walcyr Duarte Nascimento

    2018-01-01

    This work aims to implement and evaluate an interactive educational software that helps Civil Engineering students to perform and analyze the calculations related to different Soil Mechanics laboratory tests. This experience consists of an attempt to incorporate information and communication technologies (ICTs) into the engineering teaching-learning process. The content of the program is distributed into three different modules: “Compaction test”, “Consolidation test”, and “Direct shear test”...

  6. Toxicity of sediments potentially contaminated by coal mining and natural gas extraction to unionid mussels and commonly tested benthic invertebrates

    Science.gov (United States)

    Wang, Ning; Ingersoll, Christopher G.; Kunz, James L.; Brumbaugh, William G.; Kane, Cindy M.; Evans, R. Brian; Alexander, Steven; Walker, Craig; Bakaletz, Steve

    2013-01-01

    Sediment toxicity tests were conducted to assess potential effects of contaminants associated with coal mining or natural gas extraction activities in the upper Tennessee River basin and eastern Cumberland River basin in the United States. Test species included two unionid mussels (rainbow mussel, Villosa iris, and wavy-rayed lampmussel, Lampsilis fasciola, 28-d exposures), and the commonly tested amphipod, Hyalella azteca (28-d exposure) and midge, Chironomus dilutus (10-d exposure). Sediments were collected from seven test sites with mussel communities classified as impacted and in proximity to coal mining or gas extraction activities, and from five reference sites with mussel communities classified as not impacted and no or limited coal mining or gas extraction activities. Additional samples were collected from six test sites potentially with high concentrations of polycyclic aromatic hydrocarbons (PAHs) and from a test site contaminated by a coal ash spill. Mean survival, length, or biomass of one or more test species was reduced in 10 of 14 test samples (71%) from impacted areas relative to the response of organisms in the five reference samples. A higher proportion of samples was classified as toxic to mussels (63% for rainbow mussels, 50% for wavy-rayed lampmussels) compared with amphipods (38%) or midge (38%). Concentrations of total recoverable metals and total PAHs in sediments did not exceed effects-based probable effect concentrations (PECs). However, the survival, length, or biomasses of the mussels were reduced significantly with increasing PEC quotients for metals and for total PAHs, or with increasing sum equilibrium-partitioning sediment benchmark toxic units for PAHs. The growth of the rainbow mussel also significantly decreased with increasing concentrations of a major anion (chloride) and major cations (calcium and magnesium) in sediment pore water. Results of the present study indicated that (1) the findings from laboratory tests were generally

  7. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  8. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  9. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  10. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  11. Stress Corrosion Cracking of Steel and Aluminum in Sodium Hydroxide: Field Failure and Laboratory Test

    Directory of Open Access Journals (Sweden)

    Y. Prawoto

    2012-01-01

    Full Text Available Through an investigation of the field failure analysis and laboratory experiment, a study on (stress corrosion cracking SCC behavior of steel and aluminum was performed. All samples were extracted from known operating conditions from the field failures. Similar but accelerated laboratory test was subsequently conducted in such a way as to mimic the field failures. The crack depth and behavior of the SCC were then analyzed after the laboratory test and the mechanism of stress corrosion cracking was studied. The results show that for the same given stress relative to ultimate tensile strength, the susceptibility to SCC is greatly influenced by heat treatment. Furthermore, it was also concluded that when expressed relative to the (ultimate tensile strength UTS, aluminum has similar level of SCC susceptibility to that of steel, although with respect to the same absolute value of applied stress, aluminum is more susceptible to SCC in sodium hydroxide environment than steel.

  12. The laboratory test rig with miniature jet engine to research aviation fuels combustion process

    Directory of Open Access Journals (Sweden)

    Gawron Bartosz

    2015-12-01

    Full Text Available This article presents laboratory test rig with a miniature turbojet engine (MiniJETRig – Miniature Jet Engine Test Rig, that was built in the Air Force Institute of Technology. The test rig has been developed for research and development works aimed at modelling and investigating processes and phenomena occurring in full scale jet engines. In the article construction of a test rig is described, with a brief discussion on the functionality of each of its main components. Additionally examples of measurement results obtained during the realization of the initial tests have been included, presenting the capabilities of the test rig.

  13. Laboratory experiments to test relativistic gravity

    International Nuclear Information System (INIS)

    Braginsky, V.B.; Caves, C.M.; Thorne, K.S.

    1977-01-01

    Advancing technology will soon make possible a new class of gravitation experiments: pure laboratory experiments with laboratory sources of non-Newtonian gravity and laboratory detectors. This paper proposes seven such experiments; and for each one it describes, briefly, the dominant sources of noise and the technology required. Three experiments would utilize a high-Q torque balance as the detector. They include (i) an ''Ampere-type'' experiment to measure the gravitational spin-spin coupling of two rotating bodies, (ii) a search for time changes of the gravitation constant, and (iii) a measurement of the gravity produced by magnetic stresses and energy. Three experiments would utilize a high-Q dielectric crystal as the detector. They include (i) a ''Faraday-type'' experiment to measure the ''electric-type'' gravity produced by a time-changing flux of ''magnetic-type'' gravity, (ii) a search for ''preferred-frame'' and ''preferred-orientation'' effects in gravitational coupling, and (iii) a measurement of the gravitational field produced by protons moving in a storage ring at nearly the speed of light. One experiment would use a high-Q toroidal microwave cavity as detector to search for the dragging of inertial frames by a rotating body

  14. Antifungal susceptibility testing of Aspergillus species complex in the Clinical Laboratory: how to do it, when to do it, and how to interpret it

    Directory of Open Access Journals (Sweden)

    Esther Manso

    2014-12-01

    Full Text Available The emergence of drug resistance in fungal pathogens has a profound impact on human health given limited number of antifungal drugs. Antifungal resistance in Aspergillus spp. infection can be encountered in the antifungal drug-exposed patient due to selection of intrinsically resistant species or isolates with acquired resistance belonging to species that are normally susceptible. Resistance to triazoles is not common in Aspergillus spp., however, triazole resistance in A. fumigatus appears to be increasing in several European countries in recent years and can be clinically relevant. The Clinical and Laboratory Standards Institute and European Committee on Antimicrobial Susceptibility Testing have developed breakpoints and epidemiological cutoff values that are now established for Aspergillus spp. Clinical microbiology laboratories will be employed commercial susceptibility assays, rather than reference broth microdilution methods and comparative studies are particularly important.

  15. Evaluating Laboratory Performance on Point-of-Care Glucose Testing with Six Sigma Metric for 151 Institutions in China.

    Science.gov (United States)

    Fei, Yang; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-10-01

    The aim of this study was to use Six Sigma(SM) (Motorola Trademark Holdings, Libertyville, IL) techniques to analyze the quality of point-of-care (POC) glucose testing measurements quantitatively and to provide suggestions for improvement. In total, 151 laboratories in China were included in this investigation in 2014. Bias and coefficient of variation were collected from an external quality assessment and an internal quality control program, respectively, for POC glucose testing organized by the National Center for Clinical Laboratories. The σ values and the Quality Goal Index were used to evaluate the performance of POC glucose meters. There were 27, 30, 57, and 37 participants in the groups using Optium Xceed™ (Abbott Diabetes Care, Alameda, CA), Accu-Chek(®) Performa (Roche, Basel, Switzerland), One Touch Ultra(®) (Abbott), and "other" meters, respectively. The median of the absolute value of percentage difference varied among different lots and different groups. Among all the groups, the Abbott One Touch Ultra group had the smallest median of absolute value of percentage difference except for lot 201411, whereas the "other" group had the largest median in all five lots. More than 85% of participate laboratories satisfied the total allowable error (TEa) requirement in International Organization for Standardization standard 15197:2013, and 85.43% (129/151) of laboratories obtained intralaboratory coefficient of variations less than 1/3TEa. However, Six Sigma techniques suggested that 41.72% (63/151) to 65.56% (99/151) of the laboratories needed to improve their POC glucose testing performance, in either precision, trueness, or both. Laboratories should pay more attention on the practice of POC glucose testing and take actions to improve their performance. Only in this way can POC glucose testing really function well in clinical practice.

  16. Laboratory experiments with growth potential of Cenangium ferruginosum tested on natural nutrition soils

    Directory of Open Access Journals (Sweden)

    Kunca Andrej

    2013-03-01

    Full Text Available Serious pine dieback was reported in early spring from several localities in Slovakia in 2012. Needle necrosis, bark necrosis and twig cankers were the most conspicuous symptoms on diseased trees. There were no or at least not significant damages caused by bark beetles, leaf eating insects, root rots neither tracheomycosis. We also excluded Sphaeropsis sapinea (Fr. Dyko & B. Sutton as the main pest agent, which played an important role in Pinus nigra Arnold dieback from 2000 to 2007 in Slovakia. Our laboratory inspections revealed Cenangium ferruginosum Fr. as the agent responsible for that dieback. We tested its growth capability on different natural nutrition soils in the laboratory to see the potential pathogenecity. This paper describes the pine dieback based on the field inspections and laboratory studies, and we discuss the role of predisposing factors involved in the dieback.

  17. Measurement accuracy of weighing and tipping-bucket rainfall intensity gauges under dynamic laboratory testing

    Science.gov (United States)

    Colli, M.; Lanza, L. G.; La Barbera, P.; Chan, P. W.

    2014-07-01

    The contribution of any single uncertainty factor in the resulting performance of infield rain gauge measurements still has to be comprehensively assessed due to the high number of real world error sources involved, such as the intrinsic variability of rainfall intensity (RI), wind effects, wetting losses, the ambient temperature, etc. In recent years the World Meteorological Organization (WMO) addressed these issues by fostering dedicated investigations, which revealed further difficulties in assessing the actual reference rainfall intensity in the field. This work reports on an extensive assessment of the OTT Pluvio2 weighing gauge accuracy when measuring rainfall intensity under laboratory dynamic conditions (time varying reference flow rates). The results obtained from the weighing rain gauge (WG) were also compared with a MTX tipping-bucket rain gauge (TBR) under the same test conditions. Tests were carried out by simulating various artificial precipitation events, with unsteady rainfall intensity, using a suitable dynamic rainfall generator. Real world rainfall data measured by an Ogawa catching-type drop counter at a field test site located within the Hong Kong International Airport (HKIA) were used as a reference for the artificial rain generation system. Results demonstrate that the differences observed between the laboratory and field performance of catching-type gauges are only partially attributable to the weather and operational conditions in the field. The dynamics of real world precipitation events is responsible for a large part of the measurement errors, which can be accurately assessed in the laboratory under controlled environmental conditions. This allows for new testing methodologies and the development of instruments with enhanced performance in the field.

  18. GPR Laboratory Tests For Railways Materials Dielectric Properties Assessment

    Directory of Open Access Journals (Sweden)

    Francesca De Chiara

    2014-10-01

    Full Text Available In railways Ground Penetrating Radar (GPR studies, the evaluation of materials dielectric properties is critical as they are sensitive to water content, to petrographic type of aggregates and to fouling condition of the ballast. Under the load traffic, maintenance actions and climatic effects, ballast condition change due to aggregate breakdown and to subgrade soils pumping, mainly on existing lines with no sub ballast layer. The main purpose of this study was to validate, under controlled conditions, the dielectric values of materials used in Portuguese railways, in order to improve the GPR interpretation using commercial software and consequently the management maintenance planning. Different materials were tested and a broad range of in situ conditions were simulated in laboratory, in physical models. GPR tests were performed with five antennas with frequencies between 400 and 1800 MHz. The variation of the dielectric properties was measured, and the range of values that can be obtained for different material condition was defined. Additionally, in situ GPR measurements and test pits were performed for validation of the dielectric constant of clean ballast. The results obtained are analyzed and the main conclusions are presented herein.

  19. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing.

    Science.gov (United States)

    Busquet, François; Strecker, Ruben; Rawlings, Jane M; Belanger, Scott E; Braunbeck, Thomas; Carr, Gregory J; Cenijn, Peter; Fochtman, Przemyslaw; Gourmelon, Anne; Hübler, Nicole; Kleensang, André; Knöbel, Melanie; Kussatz, Carola; Legler, Juliette; Lillicrap, Adam; Martínez-Jerónimo, Fernando; Polleichtner, Christian; Rzodeczko, Helena; Salinas, Edward; Schneider, Katharina E; Scholz, Stefan; van den Brandhof, Evert-Jan; van der Ven, Leo T M; Walter-Rohde, Susanne; Weigt, Stefan; Witters, Hilda; Halder, Marlies

    2014-08-01

    The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were analytically confirmed for 11 chemicals. Newly fertilised zebrafish eggs (20/concentration and control) were exposed for 96h to chemicals. Four apical endpoints were recorded daily as indicators of acute lethality: coagulation of the embryo, lack of somite formation, non-detachment of the tail bud from the yolk sac and lack of heartbeat. Results (LC50 values for 48/96h exposure) show that the ZFET is a robust method with a good intra- and inter-laboratory reproducibility (CV30%) for some very toxic or volatile chemicals, and chemicals tested close to their limit of solubility. The ZFET is now available as OECD Test Guideline 236. Considering the high predictive capacity of the ZFET demonstrated by Belanger et al. (2013) in their retrospective analysis of acute fish toxicity and fish embryo acute toxicity data, the ZFET is ready to be considered for acute fish toxicity for regulatory purposes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  20. 9 CFR 147.30 - Laboratory procedure recommended for the polymerase chain reaction (PCR) test for Mycoplasma...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Laboratory procedure recommended for... Examination Procedures § 147.30 Laboratory procedure recommended for the polymerase chain reaction (PCR) test... tracheal swabs in PBS or 1 mL of broth culture by a non-phenolic procedure. Centrifuge samples at 14,000 x...

  1. Mobile Energy Laboratory energy-efficiency testing programs. Semiannual report, April 1, 1991--September 30, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Parker, G. B.; Currie, J. W.

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies.

  2. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Science.gov (United States)

    2010-01-01

    ... therefrom, to human beings or animals. (2) Iodine-131, in units not exceeding 10 microcuries each for use in... microcuries each for use in in vitro clinical or laboratory tests not involving internal or external... (tritium), in units not exceeding 50 microcuries each for use in in vitro clinical or laboratory tests not...

  3. The Clementine Nickel Hydrogen Common Pressure Vessel Battery

    OpenAIRE

    Garner, Christopher

    1994-01-01

    The Clementine spacecraft was launched in January 1994 to demonstrate advanced lightweight technologies for the Ballistic Missile Defense Organization (BMDO). One of the key technologies was the first use of a multi-cell nickel hydrogen (NiH2) common pressure vessel (CPV) battery. The 5.0 inch diameter, 22 cell, 15.0 ampere-hour NiH2 CPV battery was manufactured by Johnson Controls Battery Group Inc., (JCBGI). Battery test and integration was performed by the Naval Research Laboratory (NRL). ...

  4. common laboratory investigations in obstetrics and gynaecology

    African Journals Online (AJOL)

    Enrique

    HIV diagnosis and monitoring. These 'universal' tests are often requested as screening labora- tory tests ... Rapid plasma reagin (for syphilis). • Hepatitis B. • HIV. • Alpha fetoprotein and Down's screen (α-fetoprotein, ... The biochemical diagnosis of early pregnancy is now taken for granted with the advent of the monoclonal ...

  5. SEE locomotor behavior test discriminates C57BL/6J and DBA/2J mouse inbred strains across laboratories and protocol conditions.

    Science.gov (United States)

    Kafkafi, Neri; Lipkind, Dina; Benjamini, Yoav; Mayo, Cheryl L; Elmer, Gregory I; Golani, Ilan

    2003-06-01

    Conventional tests of behavioral phenotyping frequently have difficulties differentiating certain genotypes and replicating these differences across laboratories and protocol conditions. This study explores the hypothesis that automated tests can be designed to quantify ethologically relevant behavior patterns that more readily characterize heritable and replicable phenotypes. It used SEE (Strategy for the Exploration of Exploration) to phenotype the locomotor behavior of the C57BL/6 and DBA/2 mouse inbred strains across 3 laboratories. The 2 genotypes differed in 15 different measures of behavior, none of which had a significant genotype-laboratory interaction. Within the same laboratory, most of these differences were replicated in additional experiments despite the test photoperiod phase being changed and saline being injected. Results suggest that well-designed tests may considerably enhance replicability across laboratories.

  6. Results of tritium tests performed on Sandia Laboratories decontamination system

    International Nuclear Information System (INIS)

    Gildea, P.D.; Wall, W.R.; Gede, V.P.

    1978-05-01

    The Tritium Research Laboratory (TRL), a facility for performing experiments using gram amounts of tritium, became operational on October 1, 1977. As secondary containment, the TRL employs sealed glove boxes connected on demand to two central decontamination systems, the Gas Purification System and the Vacuum Effluent Recovery System. Performance tests on these systems show the tritium removal systems can achieve concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass at inlet concentrations of 1 part per million or less for both tritium and tritiated methane

  7. Influence of nitrogen ion implantation on wear studied by a new laboratory wear test

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E.; Paszti, F.; Vertessy, Z. (Central Research Inst. for Physics, Hungarian Academy of Sciences, Budapest (Hungary))

    1991-05-01

    A new laboratory wear test is developed in which the wear trace is measured by Rutherford backscattering spectrometry. The advantage of the new test is that the wear rate is directly determinable. The new test setup has been used to study the effects of nitrogen implantation on the wear processes on 115CrV3 steel. The wear rate decreases by a factor of 2 at 4x10{sup 17} N{sup +}/cm{sup 2} implanted dose. (orig.).

  8. Going beyond audit and feedback: towards behaviour-based interventions to change physician laboratory test ordering behaviour.

    Science.gov (United States)

    Meidani, Z; Mousavi, G A; Kheirkhah, D; Benar, N; Maleki, M R; Sharifi, M; Farrokhian, A

    2017-12-01

    Studies indicate there are a variety of contributing factors affecting physician test ordering behaviour. Identifying these behaviours allows development of behaviour-based interventions. Methods Through a pilot study, the list of contributing factors in laboratory tests ordering, and the most ordered tests, were identified, and given to 50 medical students, interns, residents and paediatricians in questionnaire form. The results showed routine tests and peer or supervisor pressure as the most influential factors affecting physician ordering behaviour. An audit and feedback mechanism was selected as an appropriate intervention to improve physician ordering behaviour. The intervention was carried out at two intervals over a three-month period. Findings There was a large reduction in the number of laboratory tests ordered; from 908 before intervention to 389 and 361 after first and second intervention, respectively. There was a significant relationship between audit and feedback and the meaningful reduction of 7 out of 15 laboratory tests including complete blood count (p = 0.002), erythrocyte sedimentation rate (p = 0.01), C-reactive protein (p = 0.01), venous blood gas (p = 0.016), urine analysis (p = 0.005), blood culture (p = 0.045) and stool examination (p = 0.001). Conclusion The audit and feedback intervention, even in short duration, affects physician ordering behaviour. It should be designed in terms of behaviour-based intervention and diagnosis of the contributing factors in physicians' behaviour. Further studies are required to substantiate the effectiveness of such behaviour-based intervention strategies in changing physician behaviour.

  9. Summary of the Mol electrolysis cell test program in the CRL tritium laboratory

    International Nuclear Information System (INIS)

    Miller, J.M.; Keyes, R.J.

    1996-01-01

    The development of electrolysis technology for highly tritiated water at the Studiecentrum voor Kernenergie/Centre d'Etude de l'Energie Nucleaire (SCK/CEN), Mol, Belgium, focused on A Low Inventory Capillary Electrolyser (ALICE). The key characteristic of ALICE is its low liquid inventory, a key feature for the radio-toxicity of tritiated water. A program to test this electrolytic cell design with highly tritiated water in the Chalk River Tritium Laboratory was initiated in 1988 and extended through to early 1995. The activities conducted at CRL and associated with the experimental program-design, installation, licensing and commissioning activities- are described in this report along with the results of the test program conducted on the experimental system with non-tritiated heavy water. The installation in the CRL Tritium Laboratory consisted of three main sections: the electrolysis section, the tritium storage and supply section, and the recombination section. 16 figs., 2 tabs., 10 refs

  10. An audit of Cryptosporidium and Giardia detection in Scottish National Health Service Diagnostic Microbiology Laboratories.

    Science.gov (United States)

    Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L

    2017-06-01

    Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.

  11. Designing testing service at baristand industri Medan’s liquid waste laboratory

    Science.gov (United States)

    Kusumawaty, Dewi; Napitupulu, Humala L.; Sembiring, Meilita T.

    2018-03-01

    Baristand Industri Medan is a technical implementation unit under the Industrial and Research and Development Agency, the Ministry of Industry. One of the services often used in Baristand Industri Medan is liquid waste testing service. The company set the standard of service is nine working days for testing services. At 2015, 89.66% on testing services liquid waste does not meet the specified standard of services company because of many samples accumulated. The purpose of this research is designing online services to schedule the coming the liquid waste sample. The method used is designing an information system that consists of model design, output design, input design, database design and technology design. The results of designing information system of testing liquid waste online consist of three pages are pages to the customer, the recipient samples and laboratory. From the simulation results with scheduled samples, then the standard services a minimum of nine working days can be reached.

  12. The demand for pregnancy testing: The Aschheim–Zondek reaction, diagnostic versatility, and laboratory services in 1930s Britain

    Science.gov (United States)

    Olszynko-Gryn, Jesse

    2014-01-01

    The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014

  13. Safety in the Chemical Laboratory: Safety in the Chemistry Laboratories: A Specific Program.

    Science.gov (United States)

    Corkern, Walter H.; Munchausen, Linda L.

    1983-01-01

    Describes a safety program adopted by Southeastern Louisiana University. Students are given detailed instructions on laboratory safety during the first laboratory period and a test which must be completely correct before they are allowed to return to the laboratory. Test questions, list of safety rules, and a laboratory accident report form are…

  14. Worldwide Open Proficiency Test for X ray Fluorescence Laboratories PTXRFIAEA08: Determination of Minor and Trace Elements in Natural Soil

    International Nuclear Information System (INIS)

    2014-01-01

    The IAEA assists Member State laboratories to maintain their readiness by producing reference materials, developing standardized analytical methods, and conducting interlaboratory comparisons and proficiency tests as tools for quality control. To ensure a reliable, worldwide, rapid and consistent response, the IAEA Nuclear Spectrometry and Applications Laboratory organizes tests for Member State laboratories. This publication presents the results of the worldwide proficiency test PTXRFIAEA08 on the determination of minor and trace elements in natural soil. Methodologies, a data evaluation approach, a summary evaluation of each element and individual evaluation reports for each laboratory are also described. The test was carried out within the IAEA project Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of the project was to enhance the capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health and agriculture, and in monitoring and evaluating environmental pollution. This proficiency test was designed to identify analytical problems and to support Member State laboratories in improving the quality of their analytical results, maintaining their accreditation and providing a regular forum for discussion and technology transfer in this area. The type of sample and the concentration levels of the analytes were designed to enable the identification of potential analytical problems

  15. Does bisphenol A induce superfeminization in Marisa cornuarietis? Part I: intra- and inter-laboratory variability in test endpoints.

    Science.gov (United States)

    Forbes, Valery E; Selck, Henriette; Palmqvist, Annemette; Aufderheide, John; Warbritton, Ryan; Pounds, Nadine; Thompson, Roy; van der Hoeven, Nelly; Caspers, Norbert

    2007-03-01

    It has been claimed that bisphenol A (BPA) induces superfeminization in the freshwater gastropod, Marisa cornuarietis. To explore the reproducibility of prior work, here we present results from a three-laboratory study, the objectives of which were to determine the mean and variability in test endpoints (i.e., adult fecundity, egg hatchability, and juvenile growth) under baseline conditions and to identify the sources of variability. A major source of variability for all of the measured endpoints was due to differences within and among individuals. With few exceptions, variability among laboratories and among replicate tanks within laboratories contributed little to the observed variability in endpoints. The results highlight the importance of obtaining basic knowledge of husbandry requirements and baseline information on life-history traits of potential test species prior to designing toxicity test protocols. Understanding of the levels and sources of endpoint variability is essential so that statistically robust and ecologically relevant tests of chemicals can be conducted.

  16. [Development of a laboratory test on dried blood spots for facilitating early diagnosis of alpha-1-antitrypsin deficiency].

    Science.gov (United States)

    Balduyck, Malika; Chapuis Cellier, Colette; Roche, Denis; Odou, Marie-Françoise; Joly, Philippe; Madelain, Vincent; Vergne, Anita; Nouadje, Georges; Lafitte, Jean-Jacques; Porchet, Nicole; Beaune, Philippe; Zerimech, Farid

    2014-01-01

    Alpha- 1-antitrypsin (A1AT) deficiency is a hereditary autosomal codominant genetic disorder resulting in low circulating levels of A1AT and leading to lung and/or liver disease. It remains underdiagnosed and only 5 to 10% of PIZZ patients, the most common form of severe A1AT deficiency, would be actually identified in France. Facilitating early diagnosis of A1AT deficiency would allow a better management of this disease; therefore we have developed and standardized in three laboratories involved in this study, a diagnostic test on dried blood spots (DBS) including quantitative A1AT measurement, phenotyping by IEF electrophoresis and, if necessary, genotyping by SERPINA1 gene sequencing. We performed a quantitative assay on 90 DBS samples by immunoturbidimetric or immunonephelometric methods. We demonstrated that both methods were suitable for this type of sampling and the results obtained were highly correlated (R(2)>0.9) between the three laboratories: for a target value of 1.00 g/L, the results obtained from the three laboratories were between 1.00 and 1.02 g/L. Phenotyping and genotyping were performed under redefined operating conditions and adapted to the analysis of DBS samples. The results were comparable with those obtained for venous blood samples. Following this work, it becomes possible to provide pulmonologists with a reliable kit to perform a capillary blood sampling on filter paper which would allow a large-scale screening of A1AT deficiency in the population particularly affected by this genetic condition.

  17. Advantages and Limitations of Anticipating Laboratory Test Results from Regression- and Tree-Based Rules Derived from Electronic Health-Record Data

    OpenAIRE

    Mohammad, Fahim; Theisen-Toupal, Jesse C.; Arnaout, Ramy

    2014-01-01

    Laboratory testing is the single highest-volume medical activity, making it useful to ask how well one can anticipate whether a given test result will be high, low, or within the reference interval ("normal"). We analyzed 10 years of electronic health records--a total of 69.4 million blood tests--to see how well standard rule-mining techniques can anticipate test results based on patient age and gender, recent diagnoses, and recent laboratory test results. We evaluated rules according to thei...

  18. EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

    Science.gov (United States)

    Jairala, Juniper C.; Durkin, Robert; Marak, Ralph J.; Sipila, Stepahnie A.; Ney, Zane A.; Parazynski, Scott E.; Thomason, Arthur H.

    2012-01-01

    As an early step in the preparation for future Extravehicular Activities (EVAs), astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. Neutral buoyancy demonstrations at NASA Johnson Space Center's Sonny Carter Training Facility to date have primarily evaluated assembly and maintenance tasks associated with several elements of the International Space Station (ISS). With the retirement of the Shuttle, completion of ISS assembly, and introduction of commercial players for human transportation to space, evaluations at the Neutral Buoyancy Laboratory (NBL) will take on a new focus. Test objectives are selected for their criticality, lack of previous testing, or design changes that justify retesting. Assembly tasks investigated are performed using procedures developed by the flight hardware providers and the Mission Operations Directorate (MOD). Orbital Replacement Unit (ORU) maintenance tasks are performed using a more systematic set of procedures, EVA Concept of Operations for the International Space Station (JSC-33408), also developed by the MOD. This paper describes the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated.

  19. [Role of medium-sized independent laboratories in control of healthcare-associated infection].

    Science.gov (United States)

    Anzai, Eiko; Fukui, Toru

    2009-05-01

    In 2006, the Ministry of Health and Welfare revised the regulations regarding the Medical Service Law. The amendments stipulate that all healthcare institutions are required to implement infection control programs. However, small hospitals and clinics have no clinical microbiology laboratories, whereas medium-sized hospitals have few medical technologists and the outsourcing of microbiology tests to independent laboratories is common. The decreasing number of laboratories and recent outsourcing tendency reflect the increasing commercialization, and, with it, the escalating number of commercially operating chains. Each independent laboratory is responsible for supporting activities related to the surveillance, control, and prevention of healthcare-associated infections in the associated small and medium-sized hospitals. The people responsible for infection control in these hospitals usually do not have a background in microbiology. The evaluation of communication between independent laboratory staff and hospital personnel, and rapid turnaround time of microbiology laboratory test reports are important elements ensuring the quality of independent laboratory work. With the pressures of financial constraints in the Japanese medical insurance system, the development of a cost-effective and practical protocol for quality assurance is a real dilemma.

  20. LABORATORY TESTING OF BENTONITE CLAYS FOR LANDFILL DESIGN AND CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Biljana Kovačević Zelić

    2007-12-01

    Full Text Available Top and bottom liners are one of the key construction elements in every landfill. They are usually made as compacted clay liners (CCLs composed of several layers of compacted clay with strictly defined properties or by the use of alternative materials such as: GCL – geosynthetic clay liner, BES – bentonite enhanced soils or bentonite/polymer mixtures. Following the state of the art experiences in the world, GCLs are used in Croatian landfills for several years, as well. Depending upon the location and the obeying function, GCLs have to fulfill certain conditions. A legislated compatibility criterion has to be proven by various laboratory tests. In the paper are presented the results of direct shear and chemical compatibility tests of GCLs as well as the results of permeability measurement of kaolin clay (the paper is published in Croatian .

  1. Study of the Permeability of Foam Conditioned Soils with Laboratory Tests

    OpenAIRE

    Borio, Luca; Peila, Daniele

    2010-01-01

    Problem statement: EPB tunneling requires that the excavated soil has a plastic and pulpy behavior to be able to apply a stabilizing pressure to the face, but it should also be impervious to counteract filtration forces that could develop ahead of the face. The evaluation of this parameter in granular soil, before and after conditioning, is therefore of key importance for a correct conditioning agents choice. Approach: A new laboratory procedure for testing the permeability of conditioned soi...

  2. Outsourcing of Academic Clinical Laboratories

    Science.gov (United States)

    Mrak, Robert E.; Parslow, Tristram G.; Tomaszewski, John E.

    2018-01-01

    American hospitals are increasingly turning to service outsourcing to reduce costs, including laboratory services. Studies of this practice have largely focused on nonacademic medical centers. In contrast, academic medical centers have unique practice environments and unique mission considerations. We sought to elucidate and analyze clinical laboratory outsourcing experiences in US academic medical centers. Seventeen chairs of pathology with relevant experience were willing to participate in in-depth interviews about their experiences. Anticipated financial benefits from joint venture arrangements often eroded after the initial years of the agreement, due to increased test pricing, management fees, duplication of services in support of inpatients, and lack of incentive for utilization control on the part of the for-profit partner. Outsourcing can preclude development of lucrative outreach programs; such programs were successfully launched in several cases after joint ventures were either avoided or terminated. Common complaints included poor test turnaround time and problems with test quality (especially in molecular pathology, microbiology, and flow cytometry), leading to clinician dissatisfaction. Joint ventures adversely affected retention of academically oriented clinical pathology faculty, with adverse effects on research and education, which further exacerbated clinician dissatisfaction due to lack of available consultative expertise. Resident education in pathology and in other disciplines (especially infectious disease) suffered both from lack of on-site laboratory capabilities and from lack of teaching faculty. Most joint ventures were initiated with little or no input from pathology leadership, and input from pathology leadership was seen to have been critical in those cases where such arrangements were declined or terminated. PMID:29637086

  3. Microscopic or occult hematuria, when reflex testing is not good laboratory practice.

    Science.gov (United States)

    Froom, Paul; Barak, Mira

    2010-01-01

    Consensus opinion suggests that hematuria found by dipstick and not confirmed on microscopic examination (<2 erythrocytes per high power field) signifies a false-positive reagent strip test result. Standard practice is to repeat the dipstick test several days later and if still positive to confirm by microscopic examination. If discordant results are obtained, experts recommend reflex testing for urinary myoglobin and hemoglobin concentrations. The question is whether or not this approach represents good laboratory practice. These recommendations are not evidence based. We conclude that the reference range for red blood cells on the reagent strip should be increased to 25x10(6) cells/L for young men, and 50x10(6) cells/L for the rest of the adult population, ranges consistent with flow cytometry reports. Confirmation reflex testing using tests that have inferior sensitivity, precision and probably accuracy is not recommended.

  4. Transportable Heavy Duty Emissions Testing Laboratory and Research Program

    Energy Technology Data Exchange (ETDEWEB)

    David Lyons

    2008-03-31

    The objective of this program was to quantify the emissions from heavy-duty vehicles operating on alternative fuels or advanced fuel blends, often with novel engine technology or aftertreatment. In the first year of the program West Virginia University (WVU) researchers determined that a transportable chassis dynamometer emissions measurement approach was required so that fleets of trucks and buses did not need to be ferried across the nation to a fixed facility. A Transportable Heavy-Duty Vehicle Emissions Testing Laboratory (Translab) was designed, constructed and verified. This laboratory consisted of a chassis dynamometer semi-trailer and an analytic trailer housing a full scale exhaust dilution tunnel and sampling system which mimicked closely the system described in the Code of Federal Regulations for engine certification. The Translab was first used to quantify emissions from natural gas and methanol fueled transit buses, and a second Translab unit was constructed to satisfy research demand. Subsequent emissions measurement was performed on trucks and buses using ethanol, Fischer-Tropsch fuel, and biodiesel. A medium-duty chassis dynamometer was also designed and constructed to facilitate research on delivery vehicles in the 10,000 to 20,000lb range. The Translab participated in major programs to evaluate low-sulfur diesel in conjunction with passively regenerating exhaust particulate filtration technology, and substantial reductions in particulate matter were recorded. The researchers also participated in programs to evaluate emissions from advanced natural gas engines with closed loop feedback control. These natural gas engines showed substantially reduced levels of oxides of nitrogen. For all of the trucks and buses characterized, the levels of carbon monoxide, oxides of nitrogen, hydrocarbons, carbon dioxide and particulate matter were quantified, and in many cases non-regulated species such as aldehydes were also sampled. Particle size was also

  5. The coupled process laboratory test of highly compacted bentonite

    International Nuclear Information System (INIS)

    Shen Zhenyao; Li Guoding; Li Shushen; Wang Chengzu

    2004-01-01

    Highly compacted bentonite blocks have been heated and hydrated in the laboratory in order to simulate the thermo-hydro-mechanical (THM) coupled processes of buffer material in a high-level radioactive waste (HLW) repository. The experiment facility, which is composed of experiment barrel, heated system, high pressure water input system, temperature measure system, water content measure system and swelling stress system, is introduced in this paper. The steps of the THM coupled experiment are also given out in detail. There are total 10 highly compacted bentonite blocks used in this test. Experimental number 1-4 are the tests with the heater and the hydrated process, which temperature distribution vs. time and final moisture distribution are measured. Experimental number 5-8 are the tests with the heater and without the hydrated process, which temperature distribution vs. time and final moisture distribution are measured. Experimental number 9-10 are the tests with the heater and the hydrated process, which temperature distribution vs. time, final moisture distribution and the swelling stress distribution at some typical points vs. time are measured. The maximum test time is nearly 20 days and the minimum test time is only 8 hours. The results show that the temperature field is little affected by hydration process and stress condition, but moisture transport and stress distribution are a little affected by the thermal gradient. The results also show that the water head difference is the mainly driving force of hydration process and the swelling stress is mainly from hydration process. It will great help to understand better about heat and mass transfer in porous media and the THM coupled process in actual HLW disposal. (author)

  6. Maintaining and assessing extended 9 test methods in accordance with ISO/IEC 17025: 2005 for Isotopes Hydrology Laboratory

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Tran Khanh Minh; Vu Hoai

    2016-01-01

    The ISO/IEC 17025:2005 ''General requirements for the competence of testing and calibration laboratories'' is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technique and management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed and maintain a quality management system in accordance with ISO/IEC 17025:2005. In 2013, Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO/IEC 17025:2005 with VILAS 670 accredited code. Scope of recognition is analyzed 14 parameters: F"-, Cl"-, NO_2"-, NO_3"-, Br"-, PO_4"3"-, SO_4"2"-, Li"+, Na"+, NH_4"+, K"+, Mg"2"+, Ca"2"+ and "3H in water by ion chromatography and liquid scintillator counting method. The laboratory has successfully implemented the task of maintaining quality management systems conform to ISO/IEC 17025: 2005 and expanded the scope of accreditation by 9 parameters in water: pH, EC, TSS, TDS, DO, BOD5, pH, Fe and Mn in 2015. (author)

  7. ANL-W 779 pond seepage test

    International Nuclear Information System (INIS)

    Braun, D.R.

    1992-11-01

    The ANL-W 779 sanitary wastewater treatment ponds are located on the Idaho National Engineering Laboratory (INEL), north of the Argonne National Laboratory -- West (ANL-W) site A seepage test was performed for two Argonne National Laboratory -- West (ANL-W) sanitary wastewater treatment ponds, Facility 779. Seepage rates were measured to determine if the ponds are a wastewater land application facility. The common industry standard for wastewater land application facilities is a field-measured seepage rate of one quarter inch per day or greater

  8. Lawrence Livermore Laboratory Nuclear Test Effects and Geologic Data Bank

    International Nuclear Information System (INIS)

    Howard, N.W.

    1976-01-01

    Data on the geology of the USERDA Nevada Test Site have been collected for the purpose of evaluating the possibility of release of radioactivity at proposed underground nuclear test sites. These data, including both the rock physical properties and the geologic structure and stratigraphy of a large number of drill-hole sites, are stored in the Lawrence Livermore Laboratory Earth Sciences Division Nuclear Test Effects and Geologic Data Bank. Retrieval programs can quickly provide a geological and geophysical comparison of a particular site with other sites where radioactivity was successfully contained. The data can be automatically sorted, compared, and averaged, and information listed according to site location, drill-hole construction, rock units, depth to key horizons and to the water table, and distance to faults. These programs also make possible ordered listings of geophysical properties (interval bulk density, overburden density, interval velocity, velocity to the surface, grain density, water content, carbonate content, porosity, and saturation of the rocks). The characteristics and capabilities of the data bank are discussed

  9. Changes in serial laboratory test results in snakebite patients: when can we safely exclude envenoming?

    Science.gov (United States)

    Ireland, Graham; Brown, Simon G A; Buckley, Nicholas A; Stormer, Jeff; Currie, Bart J; White, Julian; Spain, David; Isbister, Geoffrey K

    2010-09-06

    To determine which laboratory tests are first associated with severe envenoming after a snakebite, when (ie, how long after the bite) the test results become abnormal, and whether this can determine a safe observation period after suspected snakebite. Prospective cohort study of 478 patients with suspected or confirmed snakebite recruited to the Australian Snakebite Project from January 2002 to April 2009, who had at least three sets of laboratory test results and at least 12 hours of observation in hospital after the bite. Severe envenoming was defined as venom-induced consumption coagulopathy (VICC), myotoxicity, neurotoxicity or thrombotic microangiopathy. International normalised ratio (INR), activated partial thromboplastin time (aPTT), creatine kinase (CK) level, and neurological examination. There were 240 patients with severe envenoming, 75 with minor envenoming and 163 non-envenomed patients. Of 206 patients with VICC, 178 had an INR > 1.2 (abnormal) on admission, and the remaining 28 had an INR > 1.2 within 12 hours of the bite. Of 33 patients with myotoxicity, a combination of CK > 250 U/L and an abnormal aPTT identified all but two cases by 12 hours; one of these two was identified within 12 hours by leukocytosis. Nine cases of isolated neurotoxicity had a median time of onset after the bite of 4 hours (range, 35 min - 12 h). The combination of serial INR, aPTT and CK tests and repeated neurological examination identified 213 of 222 severe envenoming cases (96%) by 6 hours and 238 of 240 (99%) by 12 hours. Laboratory parameters (INR, aPTT and CK) and neurological reassessments identified nearly all severe envenoming cases within 12 hours of the bite, even in this conservative analysis that assumed normal test results if the test was not done.

  10. Proficiency testing for HIV, tuberculosis and malaria diagnosis in clinical laboratories in Nigeria

    Science.gov (United States)

    Onubogu, Catherine C.; Okoye, Rosemary N.; Nwokoye, Nkiru N.; Onwuamah, Chika K.; Musa, Adesola Z.; Raheem, Toyosi Y.; Aniedobe, Maureen N.; Nduaga, Samuel J.; Essien, Ini-Obong; Idigbe, Emmanuel O.

    2014-01-01

    Background Proficiency testing (PT) is a means of verifying the reliability of laboratory results, but such programmes are not readily available to laboratories in developing countries. This project provided PT to laboratories in Nigeria. Objectives To assess the proficiency of laboratories in the diagnosis of HIV, tuberculosis and malaria. Methods This was a prospective study carried out between 2009 and 2011. A structured questionnaire was administered to 106 randomly-selected laboratories. Forty-four indicated their interest in participation and were enrolled. Four rounds of pre-characterised plasma panels for HIV, sputum films for tuberculosis and blood films for malaria were distributed quarterly by courier over the course of one year. The results were returned within two weeks and scores of ≥ 80% were reported as satisfactory. Mentoring was offered after the first and second PT rounds. Results Average HIV PT scores increased from 74% to 95% from the first round to the third round, but decreased in the fourth round. For diagnosis of tuberculosis, average scores increased from 42% in the first round to 78% in the second round; but a decrease to 34% was observed in the fourth round. Malaria PT performance was 2% at first, but average scores increased between the second and fourth rounds, culminating in a fourth-round score of 39%. Many participants requested training and mentoring. Conclusions There were gross deficiencies in the quality of laboratory services rendered across Nigeria. In-country PT programmes, implemented in conjunction with mentoring, will improve coverage and diagnosis of HIV, tuberculosis and malaria. PMID:29043176

  11. 'Multiple-test' approach to the laboratory diagnosis of tuberculosis -perception of medical doctors from Ujjain, India.

    Science.gov (United States)

    Purohit, Manju Raj; Sharma, Megha; Rosales-Klintz, Senia; Lundborg, Cecilia Stålsby

    2015-08-11

    Delay in diagnosis is one of the most important factors for the control of tuberculosis (TB) in endemic countries like India. As laboratory diagnosis is the mainstay for identification of active disease, we aim to explore and understand the opinions of medical doctors about the laboratory diagnosis of TB in Ujjain, India. Sixteen qualified specialist medical doctors from Ujjain were purposefully selected for the study. Individual interviews with the doctors (13 men and 3 women), were conducted. As one interview could not be completed, data from 15 interviews were analyzed using manifest and latent content analysis. Based on perception of the doctors, the theme; 'challenges and need for the laboratory diagnosis of TB' emerged from the following subthemes: (i) Relationship between basic element of the TB diseases process such as 'Symptoms prior to diagnoses' and 'Clinical characteristics of TB', which were not specific enough to diagnose TB (ii) The prevailing conditions such as lack of explicit diagnostic tools, lead to the doctors using the 'multiple tests' or 'empiric treatment' approach (iii) The doctors proposed that there is a need for access to a rapid, single and simple diagnostic test, and a need for awareness and knowledge of the practitioners regarding specific TB investigations, and early referral to improve the situation at resource-limited settings. The medical specialists use a 'multiple test' or 'empiric treatment' approach to diagnose TB. According to the participants, there is a low dependence and uptake of the available laboratory TB investigations by medical practitioners. There is an urgent need to have a specific, simple and reliable test, and a protocol, to improve diagnosis of TB and to prevent development of resistant TB.

  12. Laboratory tests on sorption and transformation of the insecticide flubendiamide in Japanese tea field soil

    Energy Technology Data Exchange (ETDEWEB)

    Hartung, Susen [Technische Universität Braunschweig, Institute of Environmental and Sustainable Chemistry, Hagenring 30, 38106 Braunschweig (Germany); Iwasaki, Masahide; Ogawa, Naoto [Shizuoka University, Faculty of Agriculture, Department of Biological and Environmental Science, 836 Ohya, Suruga-ku, Shizuoka 422-8529 (Japan); Kreuzig, Robert, E-mail: r.kreuzig@tu-bs.de [Technische Universität Braunschweig, Institute of Environmental and Sustainable Chemistry, Hagenring 30, 38106 Braunschweig (Germany)

    2013-01-15

    Flubendiamide belongs to the modern insecticides applied in Japanese tea cultivation to control smaller tea tortrix and tea leaf roller. Since fate and behavior in soil have been only monitored sparsely and fragmentarily until today, laboratory tests were performed on sorption, leaching, biotransformation and photo-induced biotransformation of flubendiamide in two different soils. In batch equilibrium tests, K{sub d} and K{sub OC} values were 15 and 298 L kg{sup −1} for the Japanese tea field soil as well as 16 and 1610 L kg{sup −1} for the German arable field soil classifying flubendiamide to be moderately mobile and slightly mobile, respectively. The affinity to the tea field soil was additionally confirmed by soil column tests where flubendiamide was predominantly retarded in the topsoil layers resulting in a percolate contamination of only 0.002 mg L{sup −1}. In the aerobic biotransformation tests, flubendiamide did not substantially disappear within the 122-d incubation period. Due to DT{sub 50} > 122 d, flubendiamide was assessed very persistent. Supplementary, photo-induced impacts on biotransformation were studied in a special laboratory irradiation system. Despite a 14-d irradiation period, photo-induced biotransformation in the tea field soil was not identifiable, neither by HPLC/DAD nor by LC/MS/MS. 3-d irradiation tests in photosensibilizing acetone, however, showed that the primary photo-transformation product desiodo-flubendiamide was formed. How far this photochemical reaction may also occur in soil of perennial tea plant stands, however, has to be checked in field studies. - Highlights: ► Laboratory tests on sorption, leaching, microbial and photo-induced microbial transformation were performed. ► Strong sorption was revealed by batch equilibrium and column tests. ► High persistence was found in aerobic biotransformation tests. ► An enhanced biotransformation by photo-induced impacts could not be confirmed. ► Field studies are

  13. Laboratory tests on sorption and transformation of the insecticide flubendiamide in Japanese tea field soil

    International Nuclear Information System (INIS)

    Hartung, Susen; Iwasaki, Masahide; Ogawa, Naoto; Kreuzig, Robert

    2013-01-01

    Flubendiamide belongs to the modern insecticides applied in Japanese tea cultivation to control smaller tea tortrix and tea leaf roller. Since fate and behavior in soil have been only monitored sparsely and fragmentarily until today, laboratory tests were performed on sorption, leaching, biotransformation and photo-induced biotransformation of flubendiamide in two different soils. In batch equilibrium tests, K d and K OC values were 15 and 298 L kg −1 for the Japanese tea field soil as well as 16 and 1610 L kg −1 for the German arable field soil classifying flubendiamide to be moderately mobile and slightly mobile, respectively. The affinity to the tea field soil was additionally confirmed by soil column tests where flubendiamide was predominantly retarded in the topsoil layers resulting in a percolate contamination of only 0.002 mg L −1 . In the aerobic biotransformation tests, flubendiamide did not substantially disappear within the 122-d incubation period. Due to DT 50 > 122 d, flubendiamide was assessed very persistent. Supplementary, photo-induced impacts on biotransformation were studied in a special laboratory irradiation system. Despite a 14-d irradiation period, photo-induced biotransformation in the tea field soil was not identifiable, neither by HPLC/DAD nor by LC/MS/MS. 3-d irradiation tests in photosensibilizing acetone, however, showed that the primary photo-transformation product desiodo-flubendiamide was formed. How far this photochemical reaction may also occur in soil of perennial tea plant stands, however, has to be checked in field studies. - Highlights: ► Laboratory tests on sorption, leaching, microbial and photo-induced microbial transformation were performed. ► Strong sorption was revealed by batch equilibrium and column tests. ► High persistence was found in aerobic biotransformation tests. ► An enhanced biotransformation by photo-induced impacts could not be confirmed. ► Field studies are necessary to elucidate fate and

  14. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    Science.gov (United States)

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    Science.gov (United States)

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  16. Multiple cell common pressure vessel nickel hydrogen battery

    Science.gov (United States)

    Zagrodnik, Jeffrey P.; Jones, Kenneth R.

    1991-01-01

    A multiple cell common pressure vessel (CPV) nickel hydrogen battery was developed that offers significant weight, volume, cost, and interfacing advantages over the conventional individual pressure vessel (IPV) nickel hydrogen configuration that is currently used for aerospace applications. The baseline CPV design was successfully demonstrated though the testing of a 26 cell prototype, which completed over 7,000 44 percent depth of discharge LEO cycles. Two-cell boilerplate batteries have now exceeded 12,500 LEO cycles in ongoing laboratory tests. CPV batteries using both nominal 5 and 10 inch diameter vessels are currently available. The flexibility of the design allows these diameters to provide a broad capability for a variety of space applications.

  17. Study of the laboratory Vane test on mortars

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Elton [Post-Graduate Program in Structures and Civil Construction, Civil and Environmental Engineering Department, University of Brasilia Campus Universitario Darcy Ribeiro Asa Norte, 70910-900 Brasilia/DF (Brazil); Sousa, Jose G.G. de [Federal University of Vale do Sao Francisco, Av. Presidente Tancredo Neve, 100-56306-410 Petroline/PE (Brazil); Guimaraes, Elvio A. [University of Feira de Santana, Campus Universitario-BR 116, Km 03-44031-460-Feira de Santana/BA (Brazil); Silva, Francisco Gabriel S. [Post-Graduate Program in Structures and Civil Construction, University of Brasilia Campus Universitario Darcy Ribeiro Asa Norte, 70910-900 Brasilia/DF (Brazil)

    2007-01-15

    The Vane method (Vane test) is a simple but efficient method to measure the yield stress among other properties of non-Newtonian fluids. These fluids exhibit big flow effects in flat surfaces which are common in rheometers devices of different types (parallel disk or coaxial cylinder types). The yield stress values obtained with Vane method, in pastes, gels, soils and concentrated suspensions, have presented good agreement with results found elsewhere by most of the rheologic methods shown in the literature. The aim of this work is presenting a discussion on the capabilities of the Vane method, highlighting the theoretical basis, the functioning principle with some operational particularities, and some applications of the method in investigating the properties of fresh rendering mortars. Works of several authors that used the same method for fresh mortars were reviewed and experimental results of tests done by the authors of this paper using the method are also presented and discussed, focusing on the desirable workability for mortars. The Vane test method is an important tool in studying rheological properties in freshly applied mortar. It is able to define clear conditions in the applying of this material. (author)

  18. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    Science.gov (United States)

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  19. Real-Time Hardware-in-the-Loop Laboratory Testing for Multisensor Sense and Avoid Systems

    Directory of Open Access Journals (Sweden)

    Giancarmine Fasano

    2013-01-01

    Full Text Available This paper focuses on a hardware-in-the-loop facility aimed at real-time testing of architectures and algorithms of multisensor sense and avoid systems. It was developed within a research project aimed at flight demonstration of autonomous non-cooperative collision avoidance for Unmanned Aircraft Systems. In this framework, an optionally piloted Very Light Aircraft was used as experimental platform. The flight system is based on multiple-sensor data integration and it includes a Ka-band radar, four electro-optical sensors, and two dedicated processing units. The laboratory test system was developed with the primary aim of prototype validation before multi-sensor tracking and collision avoidance flight tests. System concept, hardware/software components, and operating modes are described in the paper. The facility has been built with a modular approach including both flight hardware and simulated systems and can work on the basis of experimentally tested or synthetically generated scenarios. Indeed, hybrid operating modes are also foreseen which enable performance assessment also in the case of alternative sensing architectures and flight scenarios that are hardly reproducible during flight tests. Real-time multisensor tracking results based on flight data are reported, which demonstrate reliability of the laboratory simulation while also showing the effectiveness of radar/electro-optical fusion in a non-cooperative collision avoidance architecture.

  20. Spent fuel storage cask testing and operational experience at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Eslinger, L.E.; Schmitt, R.C.

    1989-01-01

    Spent-fuel storage cask research, development, and demonstration activities are being performed for the U.S. Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management (OCRWM) as a part of the storage cask testing program. The cask testing program at federal sites and other locations supports the Nuclear Waste Policy Act (NWPA) and DOE objectives for cooperative demonstrations with the cask vendors and utilities for development of at-reactor dry cask storage capabilities for spent nuclear fuel assemblies. One research and development program for the storage cask performance testing of metal storage cask was initiated through a cooperative agreement between Virginia Power and DOE in 1984. The performance testing was conducted for the DOE and the Electric Power Research Institute by the Pacific Northwest laboratory, operated for DOE by Battelle Memorial Institute, and the Idaho National Engineering Laboratory (INEL), operated for DOE by EG ampersand G Idaho, Inc. In 1988 a cooperative agreement was entered into by DOE with Pacific Sierra Nuclear Associates (PSN) for performance testing of the PSN concrete Ventilated Storage Cask. Another closely related activity involving INEL is a transportable storage cask project identified as the Nuclear Fuel Services Spent-Fuel Shipping/Storage Cask Demonstration Project. The purpose of this project is to demonstrate the feasibility of packing, transporting, and storing commercial spent fuel in dual-purpose transport/storage casks