WorldWideScience

Sample records for kv overhead transmission

  1. Study of a phase-to-ground fault on a 400 kV overhead transmission line

    Science.gov (United States)

    Iagăr, A.; Popa, G. N.; Diniş, C. M.

    2018-01-01

    Power utilities need to supply their consumers at high power quality level. Because the faults that occur on High-Voltage and Extra-High-Voltage transmission lines can cause serious damages in underlying transmission and distribution systems, it is important to examine each fault in detail. In this work we studied a phase-to-ground fault (on phase 1) of 400 kV overhead transmission line Mintia-Arad. Indactic® 650 fault analyzing system was used to record the history of the fault. Signals (analog and digital) recorded by Indactic® 650 were visualized and analyzed by Focus program. Summary of fault report allowed evaluation of behavior of control and protection equipment and determination of cause and location of the fault.

  2. Residual life assessment of overhead transmission lines 110 kV and above and determination of their reconstruction terms

    Directory of Open Access Journals (Sweden)

    Uteuliyev Bauyrzhan

    2017-01-01

    Full Text Available In this article is given a method for assessment the residual life of overhead transmission lines on reinforced concrete supports with centrifuged poles. Reinforced concrete poles of supports, wires and lightning protection cables are adopted as the main elements. The intensity of change in the actual state parameters of these elements is determined by the laws of random variables distribution that allow predicting the residual life and the timing of repairs and reconstruction of overhead transmission lines. The parameters of natural climatic conditions and other external factors are considered by including of coefficients into the formula for changing the actual state parameters.

  3. Towers of the new 380 kV high-voltage overhead line across the Elbe

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, F; Sperl, H D; Wagemann, F

    1979-11-01

    As part of the European power transmission line between North Sweden and Southern Italy, a 380 kV rotary-current overhead line crosses the Elbe river south of Hamburg. To achieve the overhead clearance of 80 m required for navigation and the maximum line sag of 85 m, two steel trelliswork towers were constructed about 1200 m apart, each of them 227 m high. The 12 phases (cables) of the line are suspended each on three horizontal beams at a horizontal distance of 16 m. Exceptional loads far beyond the standards set in VDE 0210/5.69 have been assumed for the layout. In the case of the wind loads the frequent gales had to be considered; for ice loads, class I of the IEC/TC 11 Draft on Ice loading on Overhead Lines . Amsterdam 1977, was assumed. Some further loads are described as well as the tender procedure, supply and assembly of the towers.

  4. Composite Based EHV AC Overhead Transmission Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard

    and analysed with regard to the possibilities, limitations and risks widespread application of composite materials on EHV AC overhead transmission lines may present. To form the basis for evaluation of the useability of composite materials, dierent overhead line projects aimed at reducing the environmental...

  5. Interlaboratory comparison of measuring results of magnetic field near 400 kV overhead power line

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2012-01-01

    Full Text Available The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the laboratories was performed.

  6. Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV

    Energy Technology Data Exchange (ETDEWEB)

    Trohjell, J.E.; Vognild, I.H.

    1994-07-11

    The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

  7. On low-resistance neutral earthing mode in 20 kV overhead and cable networks

    Directory of Open Access Journals (Sweden)

    Mayorov Andrey

    2017-01-01

    Full Text Available The problems of justification and selection of the required single-phase short-circuit current values in cable and overhead networks of 20 kV with low-resistance neutral earthing are considered. It is shown that the desired values of the short-circuit current can be determined on the basis of harmonization of conflicting influencing factors: reliability of the relay protection and automation devices and required resistances of the earthing devices of electrical installations, including personnel safety. In this case, the main influencing factor is the electrical network structure and parameters

  8. Workers exposure to electric fields in 400 kV substations and overhead line works

    International Nuclear Information System (INIS)

    Elovaara, J.; Kuisti, H.; Korpinen, L.

    2010-01-01

    The maximum exposing electric field strength magnitude in the highly inhomogeneous 400 kV electric field under work conditions can reach the value of several tens of kV/m. In spite of this the average current density is, in Finland, always lower than 10 mA/m 2 . Furthermore, the total body currents or contact currents are in 400 kV works clearly less than the limit value proposed by the EU's draft for Directive. On the basis of the obtained results it can be concluded that from the limit value point of view it is not necessary to take further actions to reduce the exposure of the workers when they are working in 400 kV substations and on 400 kV overhead lines. However, because the transient peak values of the contact current can be painful and disturb work, it is advisable to develop a safe and reliable method to connect the worker and the work object in the common ground (equipotential bonding). (authors)

  9. Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination

    International Nuclear Information System (INIS)

    Deponti, F.; Fini, G.P.; Porrino, A.; Rosa, F.

    1992-06-01

    In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances

  10. Reduction of the visual impact of overhead transmission line systems through utilisation of line surge arresters as lightning protection

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    with the Technical University of Denmark, on how to lessen the visual impact of 400 kV overhead line transmission systems. In this paper omission of shield wires combined with installation of a suitable number of line surge arresters is investigated as a possible alternative to transmission lines equipped...... with shielding wires thereby reducing tower height, allowing more compact designs of towers thus minimizing the visual environment impact of the lines. Omission of shield wires in the system and instead utilizing a larger number of surge arresters in the (upper) phases of an overhead line without reduction...... will be investigated by transient simulations on a 400 kV line with either shield wires or line surge arresters. These simulations will also be used to estimate number and location of the line surge arresters in the line to ensure a satisfactory performance of the line when omitting shield wires in the tower top...

  11. First 735 kV transmission, Manicouagan, Montreal

    Energy Technology Data Exchange (ETDEWEB)

    Cahill, L

    1964-11-01

    The 735 kV transmission network of Hydro Quebec is described giving reasons for choice of voltage, stability factors level of insulation, disposition of conductors, insulators, equipment used and state of readiness of the project.

  12. Numerical noise analysis for insulator of overhead transmission line

    Science.gov (United States)

    Zhang, Yulin; Chen, Yuwen; Huang, Yu

    2018-04-01

    As an important and complex issue in aero acoustic field, a lot of explorations have been devoted to the wind-induced noise. However, there is still lack of intensive investigations for aerodynamic noise in high-voltage transmission. The overhead transmission line system leads to serious occupational noise exposure in high wind-speed environment, and the noise can even injure the electricians in charge of insulator. By using computational fluid dynamics (CFD) which combined with computational aero acoustics (CAA), this paper predicts the noise generated by insulator of high voltage electricity transmission line which explores in wind environment. The simulation results indicate that the wind velocity, the assembly angle of the insulator and its ribs' distribution are the main contributory factors for the aerodynamic noise. Specifically, when wind velocity is greater than 15m/s, the alteration of noise is not sensitive to the wind velocity; furthermore, when the assembly angle increases from 0°to 60°, the noise decreases gradually, however, if the angle is happening to be 75°or 90°, it would be even greater than that at 0°. In order to inhibit the aerodynamic noise, it is necessary to control the flow blowing across the boundary of the insulator. Consequently, the result indicates that if the outermost rib is shorter than the second one, the noise reduced evidently. This information expects to provide useful help for the extremely suppression of aerodynamic noise, and also supply practical reference material for the design and application of overhead transmission line system.

  13. HVDC transmission preferred to 750 kV ac

    Energy Technology Data Exchange (ETDEWEB)

    1965-06-25

    It is unlikely that there will be a need in Britain for ac transmission voltages above 400 kV. But with the growing load density in the large conurbations with no possibility of local generation, high voltage dc transmission is likely to be most useful. It was concluded that by 1971 the 400 kV supergrid would be nation-wide and 6,200 circuit miles should be in service. With the expansion to accommodate the large new generating stations, the 400 kV supergrid would become an extremely high power distribution network rather than a transmission system. A higher voltage for transmission is outside the rational limit of speculation for a country the size of Britain.

  14. Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    1991-06-01

    This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

  15. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2010-12-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  16. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2011-01-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  17. Overhead Transmission Lines Deicing under Different Incentive Displacement

    Directory of Open Access Journals (Sweden)

    Qing He

    2014-01-01

    Full Text Available Overhead transmission line icing is one of the main factors affecting safety and reliability of power grid. This paper proposed an excitation deicing method of iced wire and theoretically revealed the ice removal mechanism under displacement excitation conditions, by taking the LGJ-70/10 glaze icing wire as the 3D model and analyzing and studying its dynamic response under the effect of displacement excitation. The simulation results show that the stress of wire icing area is enlarged with the increase of excitation displacement and frequency. Through the comparison of the compression strength experimental results on a series of different iced wires in low temperature environment, the authors found out that the stress generated from the wire icing area is greater than the crushing strength of the ice within the scope of the calculation parameters, which proved the validity and the feasibility of the method, and finally the suitable excitation displacement is determined. Following studies show that, as far as possible, it is necessary to reduce the incentive displacement and also to select the appropriate constraint length in order to avoid the line jumping that may be caused by large span ice shedding.

  18. Big George to Carter Mountain 115-kV transmission line project, Park and Hot Springs Counties, Wyoming. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead ground wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.

  19. Structural health monitoring of compression connectors for overhead transmission lines

    Science.gov (United States)

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P.; Ren, Fei; Chan, John

    2017-04-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over electrical conducting aluminum strands. The connectors are designed to operate at temperatures up to 125°C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements, but these methods do not provide information about the structural integrity of connectors. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to induce structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  20. Comparison between IEEE and CIGRE Thermal Behaviour Standards and Measured Temperature on a 132-kV Overhead Power Line

    Directory of Open Access Journals (Sweden)

    Alberto Arroyo

    2015-12-01

    Full Text Available This paper presents the steady and dynamic thermal balances of an overhead power line proposed by CIGRE (Technical Brochure 601, 2014 and IEEE (Std.738, 2012 standards. The estimated temperatures calculated by the standards are compared with the averaged conductor temperature obtained every 8 min during a year. The conductor is a LA 280 Hawk type, used in a 132-kV overhead line. The steady and dynamic state comparison shows that the number of cases with deviations to conductor temperatures higher than 5 ∘ C decreases from around 20% to 15% when the dynamic analysis is used. As some of the most critical variables are magnitude and direction of the wind speed, ambient temperature and solar radiation, their influence on the conductor temperature is studied. Both standards give similar results with slight differences due to the different way to calculate the solar radiation and convection. Considering the wind, both standards provide better results for the estimated conductor temperature as the wind speed increases and the angle with the line is closer to 90 ∘ . In addition, if the theoretical radiation is replaced by that measured with the pyranometer, the number of samples with deviations higher than 5 ∘ C is reduced from around 15% to 5%.

  1. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    400 kV power system and initiated by Danish TSO Energinet.dk after having measured the voltage of the cable/overhead line after disconnection. A particular decaying dynamic phase voltage containing voltages higher than the voltage before disconnection appeared. A simulation model for the entire system...

  2. Technical and economic data for overhead lines in high-voltage a. c. and d. c. transmission

    Energy Technology Data Exchange (ETDEWEB)

    1977-11-01

    For the study of 'High-power electricity transmission and distribution in densely populated areas' technical and economic data were compiled for high-voltage alternating current and direct current transmission. A modification of the overhead lines for transmitting higher powers is possible as required by means of higher rated transmission voltages, larger conductor cross-sections and a larger number of circuits installed on each mast. For the use of larger partial conductor cross-sections and of bundle conductors with more than 4 partial conductors, and also to use voltages higher than 380 kV, development work is requisite from the points of view of construction, installation, insulators and fittings. Further possible developments result from the use of new materials such as plastic insulators which make possible the use of more versatile shapes for application in heavy pollution, particulary for direct current overhead lines. By using insulating crossarms the width of path can be considerably reduced. Economic efficiency investigations show even today higher cost for such techniques compared with lines of earlier construction.

  3. Study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission from overhead High-Voltage Transmission Lines

    International Nuclear Information System (INIS)

    Parthasarathy, S.R.; Roha Tukimin; Wan Saffiey Wan Abdullah; Zulkifli Yusof; Mohd Azizi Mohd Jali

    2016-01-01

    The paper highlights the study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission performed at an overhead 275-kV High-Voltage Transmission Lines. The study comprised of assessment at the transmission lines on 3 different cases and locations in Klang Valley, specifically on a vacant land near the transmission line, inside and around the house at the vicinity of the transmission line and the area directly under the transmission line. The instrument setup and measurement protocols during the assessment were adopted from standard measurement method and procedures stipulated under the Institute of Electrical and Electronics Engineers (IEEE) Standard. The results were compared with the standards recommended in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The results showed that the measured field strengths are within the safety limit with the highest measured exposure was 10.8 % and 1.8 % of the permissible exposure limit for the electric and magnetic field respectively. Both the field strengths were found to drop significantly against distance from the transmission lines where closer distances showed higher field strengths. Furthermore, the study revealed that buildings and other object such as trees and shrubs screen out the electric field, resulting in a lower value at indoor measurements and near the stated objects. In addition, higher value of electric and magnetic field strengths were recorded when assessment was being done directly under the transmission line compared to the lateral measurement. (author)

  4. Wild Horse 69-kV transmission line environmental assessment

    International Nuclear Information System (INIS)

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline's pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE's review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest

  5. Wild Horse 69-kV transmission line environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

  6. Tracing overhead transmission line corridors with regard to environmental and spatial qualities

    Directory of Open Access Journals (Sweden)

    Alenka Cof

    2005-01-01

    Full Text Available The article deals with possibilities for running the proposed overhead transmission line Okroglo-Italian border. The Slovene and Italian methods are shown as methods enabling consideration of environmental and spatial impact within the process of planning overhead transmission line corridors. The Slovene method consists of analyses of attractiveness and vulnerability, whereby the first considers those functional and economic factors that affect spatial attractiveness for overhead transmission lines. Thus we can assess the level of economic and functional suitability of alternative routes of the proposed 400 kilovolt overhead transmission line from transformation station Okroglo (Slovenia to Srednje, Golo Brdo and Vrtojba, three potential contact points on the Slovene–Italian border. In accordance with stipulations of the Law on spatial management vulnerability models were prepared, which were used to simulate the development’s potential negative environmental effects and to analyse suitability, which implies harmonisation of development and protection demands. Their result is a possible corridor that can be developed without significant conflicts. The Italian procedure was developed to trace the transmission line corridor from the Slovenian border to the transformation station in Udine. It was also applied on the Slovenian side. Three groups of factors were considered in the procedure: exclusion, repulsion, and attraction. The much simpler procedure enables comparisons, since it uses the same or at least similar spatial data. In conclusion a short commentary is added about the corridor concept as a planning tool.

  7. Spatial Analysis of Thermal Aging of Overhead Transmission Conductors

    Czech Academy of Sciences Publication Activity Database

    Musílek, P.; Heckenbergerová, Jana; Bhuiyan, M.M.I.

    2012-01-01

    Roč. 27, č. 3 (2012), s. 1196-1204 ISSN 0885-8977 Grant - others:GA AV ČR(CZ) M100300904 Source of funding: V - iné verejné zdroje Keywords : aluminium conductor steel reinforced (ACSR) conductor * hot spot * loss of tensile strength * numerical weather prediction * power transmission lines * thermal aging Subject RIV: JE - Non-nuclear Energetics, Energy Consumption ; Use Impact factor: 1.519, year: 2012

  8. Power System Reliability Assessment by Analysing Voltage Dips on the Blue Horizon Bay 22KV Overhead Line in the Nelson Mandela Bay Municipality

    Science.gov (United States)

    Lamour, B. G.; Harris, R. T.; Roberts, A. G.

    2010-06-01

    Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.

  9. Survey of magnetic fields near BPA 230-kV and 500-kV transmission lines

    International Nuclear Information System (INIS)

    Perrin, N.; Aggarwal, R.P.

    1991-01-01

    The purpose of this study was to characterize typical levels and variability of 60Hz magnetic fields at the centerline and edge of right-of-way of Bonneville Power Administration (BPA) 230-kV and 500-kV transmission lines. This was accomplished by taking magnetic field measurements at over 800 spans in Oregon and Washington. The spans were sampled using a stratified random sampling procedure with region (East vs. West), voltage (230-kV vs 500-kV), and circuit configuration as strata. There were five different circuit configuration groups for each region/voltage category requiring a total of 200 strata. Magnetic field measurements were taken at 13 locations under each span using an EMDEX-C as a survey meter. Additional information recorded for each span included conductor height (at 10 locations), right-of-way width, longitudinal and lateral slope, time of day, vegetation, terrain, weather conditions, temperature, wind speed, span length and presence of other lines in the corridor. 9 refs., 17 figs., 26 tabs

  10. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  11. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    International Nuclear Information System (INIS)

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park

  12. STUDY ON PERFORMANCE OF 21M 132kV TRANSMISSION TOWER WITH MEDIUM WIND INTENSITY

    OpenAIRE

    V. LAKSHMI; A. RAJAGOPALA RAO

    2012-01-01

    Electric Power is today playing an increasingly important role in the life of the community. In the electric power system the production and transmission of power are two predominant factors. For the purpose of transmission of electricity towers are the main medium with some wires at required distances and altitudes. The remotehydroelectric power plants have given rise to the need for extra high voltage. Prior to 1950, 150 kV electric transmission lines were considered and still higher voltag...

  13. Analysis of a back flashover across insulator strings on a 115 kV transmission line tower by PSCAD

    Directory of Open Access Journals (Sweden)

    Worakit Anekthanasuwan

    2015-09-01

    Full Text Available Lightning striking on a transmission tower induces high ground potential rise and high voltage at tower arms in which potential is normally at ground level, and subsequently causes overvoltage across an insulator string. If this overvoltage is higher than the withstanding voltage of the insulator string according to the v-t (voltage-time curve, back flashover phenomena will occur and this event may cause outage. The main objective of this paper is to study the factors influencing the back flashover phenomena. The computer program PSCAD/EMTDC (Power System Computer Aided Design/Electromagnetic Transients including DC is used to simulate lightning striking on a transmission tower 115kV. Lightning current, transmission towers, ground resistance, insulator strings and back flashover phenomena are modeled. Main simulations are lightning striking on different towers, different soil resistivity, different lightning current magnitudes and wave shapes, different locations, and different phase angles of source voltage. Simulation results show that the higher tower encounters higher induced voltage. A back flashover occurs at the top tower arm easier than at the middle and lower arms. The higher soil resistivity induces higher voltage. The larger lightning current magnitude impacts on higher induced voltage. The longer rise time of lightning current generates lower induced voltage. Lightning strikes directly on tower generate higher voltage than that of striking on overhead ground wires.

  14. Measurements of Voltage Harmonics in 400 kV Transmission Network

    Directory of Open Access Journals (Sweden)

    Ryszard Pawełek

    2014-06-01

    Full Text Available The paper deals with the analysis of voltage harmonics measurements performed in the 400 kV transmission network. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.

  15. Full Scale Experimental Study on the Air Insulation of 765kV Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Boo; Shin, Jeong Woon; Cho, Sung Bae; Chang, Sung Chil; Kwak, Joo Shik [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Kim, Ik Soo; Lee, Heyoung Ho; Kang, Young Sik; Lee, Hong Sik; Choi, Beyoung Joo; Kim, Young Bae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1997-12-31

    Design and construction of testing yard. Technical specification of impulse voltage generator which was installed in testing yard. Corrosion and statistical analysis of test data. Test object setup and test results of flashover characteristic in various paths. Recommended optimum air clearance of 765kV transmission lines. (author). 163 refs., figs.

  16. Voltage Analysis Improvement of 150 kV Transmission Subsystem Using Static Synchronous Compensator (STATCOM)

    Science.gov (United States)

    Akbar, P. A.; Hakim, D. L.; Sucita, T.

    2018-02-01

    In this research, testing improvements to the distribution voltage electricity at 150 kV transmission subsystem Bandung Selatan and New Ujungberung using Flexible AC Transmission System (FACTS) technology. One of them is by doing the control of active and reactive power through the power electronics equipment Static Synchronous Compensator (STATCOM). The subsystem is tested because it has a voltage profile are relatively less well when based on the IEEE / ANSI C.84.1 (142.5 - 157.5 kV). This study was conducted by analyzing the Newton-Raphson power flow on the simulator DigSilent Power Factory 15 to determine the profile of the voltage (V) on the system. Bus which has the lowest voltage to be a reference in the installation of STATCOM. From this research is known that the voltage on the conditions of the existing bus 28, as many as 21-23 still below standard buses (142.5 kV), after the installation is done using STATCOM, voltage on the buses improved by increasing the number of tracks that follow the standard / is in the range 142.5 kV -157.5 kV as many as 23-27 buses or 78.6% - 96%, with the optimum mounting on a bus Rancaekek STATCOM II with a capacity of 300 MVA.

  17. Research on Line Patrol Strategy of 110kV Transmission Line after Lightning Strike

    Directory of Open Access Journals (Sweden)

    Li Mingjun

    2016-01-01

    Full Text Available Lightning faults occupy in the majority of instantaneous fault and reclosing can usually be successful, so power supply can be restored without immediate patrol in many cases. Firstly, this paper introduces the lightning fault positioning and identifying method. Then test electrical performance of insulators after lightning strike from 110kV lines. Data shows that lightning strike has little effect on the electric performance of insulator. Finally, illustrating disposal process of the 110 kV transmission line after lightning fault, certifying that the power supply reliability be ensured without line patrol.

  18. Electrical transmission

    Energy Technology Data Exchange (ETDEWEB)

    Sayers, D P

    1960-05-01

    After briefly tracing the history of electricity transmission, trends in high voltage transmission and experiments being conducted on 650 kV are discussed. 5000 miles of the U.K. grid are operated at 132 kV and 1000 at 275 kV, ultimately to provide a super grid at 380 kV. Problems are insulation, radio interference and the cost of underground lines (16 times that of overhead lines). Also considered are the economics of the grid as a means of transporting energy and as a means of spreading the peak load over the power stations in the most efficient manner. Finally, the question of amenities is discussed.

  19. To Solution of Classical Problem Pertaining to Magnetic Interference of Overhead Power Transmission Line on Extended Conducting Communications

    Directory of Open Access Journals (Sweden)

    V. I. Glushko

    2013-01-01

    Full Text Available The paper considers a problem pertaining to magnetic interference of overhead power transmission lines and high-voltage bus bars of electrical installations on extended conducting communications and secondary circuits of relay protection and automation. A simplified task solution has been obtained on the basis of the Carson integral approximation.

  20. Model for the ready definition and approximate comparison of alternative high voltage transmission systems. Phases II and III. Application to electric systems within the contiguous United States. [800 and 1200 kV; 400, 600, and 800 kV dc

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    Research on power delivery alternatives is reported. The first phase of this work was to develop a model of overhead transmission systems in the range of 362 to 1200 kV ac, and +-400 to +-800 kV dc. Such systems included transmission from generation to load and inter-connection of two large integrated systems, with and without the existence of an underlying lower voltage network in either case. This phase has been completed. The second and third phases involved application of the model to electric systems within selected regions of the US, and the entire US, respectively, dealing with real situations and including projected expansion to year 1987. The potential benefits and costs of using higher than existing transmission voltages were to be evaluated on this basis. Additionally, the most advantageous new voltage was to be determined taking into account direct and indirect benefits and costs. The results of the second and third phases are presented.

  1. California-Oregon 500-kV transmission line development of design criteria

    International Nuclear Information System (INIS)

    Simpson, K.D.

    1990-01-01

    The California-Oregon Transmission Project (COTP) encompassed the design and construction of a third 500-kV ac intertie between California and the Pacific Northwest Transmission system. Sargent ampersand Lundy's (S ampersand L) scope of work in the COTP includes the design of approximately 150 miles of new single-circuit, 500-kV transmission line from southern Oregon to the vicinity of Redding, California. This paper presents the development of the design criteria for this segment of the project, which crosses diverse topographic and climatic regions. This project is an example of the increasing utilization of computers in transmission line engineering. Almost all aspects of design involved the use of the computer. Also, the development of the design criteria for this project coincided with an early release of the TLWorkstation software package by EPRI. TLWorkstation is an engineering workstation containing a family of programs for various aspects of transmission line design. This engineering software allows for increasing refinement in the design and economic optimization of transmission lines and is becoming an important design tool for transmission engineers

  2. Method of selecting optimum cross arm lengths for a 750 kV transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, G N; Olorokov, V P

    1965-01-01

    A method is presented, based on both technical and economic considerations, for selecting cross arm lengths for intermediate poles of power transmission lines according to the effects of internal overvoltage, methods from probability theory and mathematical statistics employed. The problem of optimum pole size is considered in terms of the effect of internal overvoltages for a prescribed maximum level of 2.1 PU currently used in the USSR for the design of 750 kV lines.

  3. A theoretical model of rain–wind–induced in-plane galloping on overhead transmission tower-lines system

    Directory of Open Access Journals (Sweden)

    Chao Zhou

    2015-09-01

    Full Text Available Rain–wind–induced galloping phenomenon often occurs on overhead transmission tower-lines system, just as icing galloping and vortex-excited vibration; this kind of instability oscillation can cause power-line breakage or tower failure. However, the existing theoretical models of rain–wind–induced galloping are mainly based on the hypothesis of the overhead power-lines with fixed ends, which is inconsistent with the actual operation situation. Therefore, this article thus presents a preliminary theoretical study and proposes a new theoretical model taking into account the effect of tower excitations on the in-plane galloping of the overhead power-line and on the motion of the upper rain-line. The theoretical model is solved by Galerkin method and verified by the comparison with the test data obtained in the available literature involved with the overhead power-lines with fixed towers or moving towers. It turns out that the tower excitations may intensify the in-plane galloping amplitude of the overhead power-line within a certain range of frequency ratio and enable better comprehension of rain–wind–induced galloping mechanism.

  4. A study on the insulation coordination of 765 kV system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Boo; Shim, Eung Bo [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Lee, Yong Han; Youn, Jae Yeong; Hwang, Chi Woo; Jung, Dong Hak [Korea Electrotechnology Research Inst., Changwon (Korea, Republic of)

    1996-12-31

    Analysis of the power frequency temporary overvoltage. Analysis of switching surges - Fault imitation, closing and re closing, fault clearing. Analysis of lightning surges. Insulation design of 765 kV overhead transmission line. Insulation coordination of 765 kV gas insulated substation. Transient recovery voltage and high speed ground switch (author). 38 refs., 55 figs.

  5. Smart patch integration development of compression connector structural health monitoring in overhead transmission lines

    Science.gov (United States)

    Wang, Hong; Wang, Jy-An J.; Ren, Fei; Chan, John

    2016-04-01

    Integration of smart patches into full-tension splice connectors in overhead power transmission lines was investigated. Lead zirconate titanate (PZT) -5A was used as a smart material and an aluminum beam was used as a host structure. Negative electrode termination was examined by using copper adhesive tape and direct bonding methods. Various commercial adhesives were studied for PZT integration onto the host structure. Aluminum beam specimens with integrated PZT smart patches were tested under thermal cycling at a temperature of 125°C, which is the higher-end temperature experienced by in-service aluminum conductor steel-reinforced cables. Electromechanical impedance (EMI) measurements were conducted at room temperature, and the root mean square deviation (RMSD) of the conductance signals was used to analyze the EMI data. It has been shown that the negative electrode method has an important effect on the performance of the integrated PZT. The PZT displayed more susceptibility to cracking when copper tape was used than when direct bonding was used. The reliability of PZT in direct bonding depended on the adhesives used in bonding layers. Although a hard alumina-based adhesive can lead to cracking of the PZT, a high-temperature epoxy with adequate flexibility, such as Duralco 4538D, can provide the desired performance under target thermal cycling conditions. The RMSD parameter can characterize conductance signatures effectively. It also was demonstrated that RMSD can be used to quantify the fatigue of the PZT integration system, although RMSD is used primarily as a damage index in monitoring structural health.

  6. The Way of Reducing Current Values in Optical Ground Wires at Asymmetrical Faults on Overhead Transmission Lines

    Directory of Open Access Journals (Sweden)

    Egamnazarov Georgiy

    2016-12-01

    Full Text Available Given the fact that the installing costs of an optical ground wire on overhead lines directly depend on its cross-section, which in turn depends on the level of fault current it should withstand, in order to reduce these current values in the optical ground wire, I suggested performing its isolated descents from the end towers of the line with its transition to an optical cable. The research was carried out on the example of a 500 kV overhead line in the National Electric Power Grid. The Method of Symmetrical Components for calculating asymmetrical fault currents was not used; therefore, calculations were carried out on the base of presenting the line as a multi-wire system for the considered case as a five-wire system (optical ground wire, steel ground wire, and three phase wires. Such approach allows taking into account the initial asymmetry of the line parameters and modeling any kind of asymmetrical faults. The analyses of calculated results were performed. The conclusive evidence that the optical ground wire isolated descents from the end towers of the line give the possibility of reducing the level of maximal fault current distribution values in it and therefore its cross section, is presented.

  7. Impact of Considering 110 kV Grid Structures on the Congestion Management in the German Transmission Grid

    Science.gov (United States)

    Hoffrichter, André; Barrios, Hans; Massmann, Janek; Venkataramanachar, Bhavasagar; Schnettler, Armin

    2018-02-01

    The structural changes in the European energy system lead to an increase of renewable energy sources that are primarily connected to the distribution grid. Hence the stationary analysis of the transmission grid and the regionalization of generation capacities are strongly influenced by subordinate grid structures. To quantify the impact on the congestion management in the German transmission grid, a 110 kV grid model is derived using publicly available data delivered by Open Street Map and integrated into an existing model of the European transmission grid. Power flow and redispatch simulations are performed for three different regionalization methods and grid configurations. The results show a significant impact of the 110 kV system and prove an overestimation of power flows in the transmission grid when neglecting subordinate grids. Thus, the redispatch volume in Germany to dissolve bottlenecks in case of N-1 contingencies decreases by 38 % when considering the 110 kV grid.

  8. The 12th 735-kV transmission line project: Hydro-Quebec network

    International Nuclear Information System (INIS)

    1992-01-01

    Hydro-Quebec is proposing to construct a 735-kV transmission line from the Chissibi station near the LG3 hydroelectric power plant to the Jacques-Cartier station near Quebec City. The width of the right-of-way will generally be 90 m and it is intended to install the line in two stages. The Chissibi-Chibougamau section should enter service in 1993 and the Chibougamau-Cartier section in 1994. The cost of the line is estimated at $1.21 billion, of which $900 million is for line construction and $310 million for station equipment. Prospective corridors for the line route have been selected, portions of which enable twinning with Hydro-Quebec's existing 9th 735-kV line. A series of hearings on the environmental and other impacts of the power line project was held by the Bureau d'audiences publiques sur l'environnement and results are summarized along with the views of the Bureau. The summary describes the justification for the project, the choice of the transmission line route, the evaluation of the impacts of the project on the natural and human environments, health effects due to magnetic fields, and effects on the economic development of northern Quebec. Recommendations are given for mitigating the impacts of the project. 13 refs., 8 figs., 2 tabs

  9. Choice of 735 kV transmission economics and system performance

    Energy Technology Data Exchange (ETDEWEB)

    McGillis, D T

    1966-01-01

    The present Hydro Quebec load is 8,000 MW and is expected to be 16,000 MW by the late 1970's and 26,000 MW by the middle of the 1980's. This load is concentrated in the area along the St. Lawrence River between Quebec City and Montreal where most of Quebec's six million people live. Fortunately there is in the Province of Quebec enough hydroelectric potential to meet the increase in load that is expected to develop over the next 15 to 20 years. These new sources are, however, at least 500 miles away from the Montreal-Quebec load area. Though this consideration had some bearing on the planning of the Hydro-Quebec ehv network, the choice of 735 kV transmission for the Manicouagan-Outardes project was based principally on economic studies of alternative transmission facilities for this specific project.

  10. Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado

    International Nuclear Information System (INIS)

    1996-05-01

    The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO's circuit on new right-of-way, and reconductoring Western's existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations

  11. Energized overhead ground wires - OHGWs the pioneer Brazilian application

    Energy Technology Data Exchange (ETDEWEB)

    D` Ajuz, Ary; Martinez, Manuel L.B.; Araujo, Ana Maria R; Takai, Mario Noboru; Sganzerla, Flavio [ELETRONORTE, Brasilia, DF (Brazil); O, Junior, Helio P; Fonseca, Claudio S [Marte Engenharia (Brazil); Guimaraes, R P; Mendes, Eloisa R

    1994-12-31

    This paper introduces an economical solution for close HV lines small villages and farms load supply. The needed modifications to adapt a planned transmission system to supply loads located along the lines routes are presented. The paper describes the two overhead ground wires scheme planned for implementation in the 230 kV transmission line under construction by ELETRONORTE in Mato Grosso and Rondonia supplying loads each one totaling roughly 8 MW. (author) 4 refs., 4 figs., 2 tabs.

  12. Flatiron-Erie 115kV transmission line project, Larimer, Weld and Boulder Counties, Colorado

    International Nuclear Information System (INIS)

    1993-05-01

    Western Area Power Administration (Western) proposes to uprate its existing 115-kV Flatiron-Erie transmission line. The line is located in Larimer, Weld and Boulder Counties, Colorado, and passes through the City of Longmont. The line connects Flatiron Substation and several of the substations supplying Longmont. It is a single circuit 115-kV line, 31.5 miles long, and was built in 1950-51 on a 75-foot wide right-of-way (ROW) using wood H-frame structures. Western proposes to build 27 new structures along the line, to replace or modify 45 of the existing structures and to remote 11 of them. Many of these additions and changes would involve structures that are approximately 5 to 15 feet taller than the existing ones. The existing conductors and ground wires would remain in place. The purpose of these actions would be to allow the power carrying capability of the line to be increased and to replace deteriorating/structural members. Western would be the sole participant in the proposed project. This report gives an analysis of the study area environment and the development of alternative routes. An assessment is presented of the impacts of the primary alternative routes. The environmental consequences of this project are addressed

  13. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    consisting of overhead lines, crossbonded cable sections and shunt reactor has been created in PSCAD/EMTDC and verified against measurements with good results. Main focus has been put on the likelihood of having a successful single-phase autoreclosure ARC in such a combined cable/OHL line....

  14. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

  15. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    International Nuclear Information System (INIS)

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA)

  16. 75 FR 9573 - Minnkota Power Cooperative, Inc: Bemidji-Grand Rapids 230kV Transmission Project

    Science.gov (United States)

    2010-03-03

    ... Rapids 230kV Transmission Project AGENCY: Rural Utilities Service, USDA. ACTION: Notice of Availability... copy of the Draft EIS may be viewed online at the following Web sites: http://www.usda.gov/rus/water..., Longville, MN 56655; Walker Public Library, 207 4th St., Walker, MN 56484; Bovey Public Library--Village...

  17. 75 FR 75170 - Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission Line Project

    Science.gov (United States)

    2010-12-02

    ... availability of Record of Decision. SUMMARY: The Rural Utilities Service, hereinafter referred to as RUS and/or the Agency, has issued a Record of Decision (ROD) for the Environmental Impact Statement (EIS) for the... financing to construct the 230 kilovolt (kV) transmission line between the Wilton Substation near Bemidji...

  18. Improving the Transmission System Reliability for the 154kV Radial Network Operation

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jin Boo; Yoo, Myeong Ho; Yoon, Young Beum; Kim, Tae Won [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Lee, Gi Won; Chung, Beom Jin; Jung, Jung Won; Park, Kyu Hyun; Lee, Myung Hee; Kim, Hyun Jong; Kim, Chae Hee [KEYIN CO., (Korea, Republic of)

    1996-12-31

    Analyzing that 154kV radial network current ed operated, we developed Automatic Power Reconfiguration System(APRS) which restore blackout area. It consists of special data acquisition system(DAU) and central monitoring system for reason of protecting currently operating power system. In addition, it communicates using optical communication network for high speed data transmission and accuracy. An Accuracy of operation and stability of the developed system is tested using Real Time Digital Simulator in 3-bus equivalent model system. In An Outage case, our developed system can restore a blackout area in three second. An ability of the restoration of a blackout was verified by simulations. For the field test, the developed system was set up at SINCHON S/S, SESOMUN S/S, SINDANG S/S and MAJANG S/S governed by Seoul Power Transmission Center. If the system reliability is proved for a one year test in real power system, application of the system will be extended to the other substations.

  19. Novel adaptive distance relay algorithm considering the operation of 154 kV SFCL in Korean power transmission system

    International Nuclear Information System (INIS)

    Lee, S.; Lee, J.; Song, S.; Yoon, J.; Lee, B.

    2015-01-01

    Highlights: • This paper presents an outline of the new project of the 154 kV SFCL in Korea. • And then we review some protection problems for the application of 154 kV SFCLs. • This paper proposes a new adaptive protection algorithm for 154 kV SFCLs. • The developed algorithm is tested in a simple distance relay system. - Abstract: In general, SFCLs can have a negative impact on the protective coordination in power transmission system because of the variable impedance of SFCLs. It is very important to solve the protection problems of the power system for the successful application of SFCLs to real power transmission system. This paper reviews some protection problems which can be caused by the application of 154 kV SFCLs to power transmission systems in South Korea. And then we propose an adaptive protection algorithm to solve the problems. The adaptive protection algorithm uses the real time information of the SFCL system operation.

  20. Life Cycle Assessment on a 765 kV Venezuelan Transmission System

    International Nuclear Information System (INIS)

    Wang, Wenlu; Tremouille, Gilles; Beroual, Abderrahmane; Bessede, Jean-Luc

    2011-03-01

    The demand to preserve the environment and form a sustainable development is greatly increasing in the recent decades all over the world, and this environmental concern is also merged in electrical power industry, resulting in many eco-design approaches in T and D industries. As a method of eco-design, Life Cycle Assessment (LCA) is a systematic tool that enables the assessment of the environmental impacts of a product or service throughout its entire life cycle, i.e. raw material production, manufacture, distribution, use and disposal including all intervening transportation steps necessary or caused by the product's existence. In T and D industries, LCA has been done for a lot of products individually, in order to see one product's environmental impacts and to seek for ways of improving its environmental performance. This eco-design for product approach is a rather well-developed trend, however, as only a single electrical product cannot provide the electrical power to users, electrical system consists of a huge number of components, in order to investigate system's environmental profile, the entire environmental profiles of different composing products has to be integrated systematically, that is to say, a system approach is needed. Under this philosophy, in this paper, an LCA using SimaPro (one kind of LCA software) is conducted on a whole Venezuelan 765 kV AC transmission system, which transmits 8000 MW hydro-electrical power through 760 km to this country's load centers, with total 7 substations, i.e. one sending end, 2 intermediate substations and 4 receiving ends. This LCA includes both transmission lines and substations, and then the environmental impacts of the whole transmission system are investigated. (authors)

  1. Prediction of the Voltage Quality in an Overhead Transmission Line with Distributed Parameters

    OpenAIRE

    Bulyga Leonid L.; Tarasov Evgeniy V.; Ushakov Vasily Ya.; Kharlov Nikolay N.

    2015-01-01

    The present work is devoted to investigation of an electrical transmission line with allowance for distributed parameters. From the results of voltage measurements at terminals of an actual transmission line, effective values of the voltage are calculated for every line section. Special attention is given to higher harmonics and asymmetry. Spectral composition of the voltage is presented and changes in values of harmonic components are analyzed. The effect of higher harmonics on the equipment...

  2. Prediction of the Voltage Quality in an Overhead Transmission Line with Distributed Parameters

    Directory of Open Access Journals (Sweden)

    Bulyga Leonid L.

    2015-01-01

    Full Text Available The present work is devoted to investigation of an electrical transmission line with allowance for distributed parameters. From the results of voltage measurements at terminals of an actual transmission line, effective values of the voltage are calculated for every line section. Special attention is given to higher harmonics and asymmetry. Spectral composition of the voltage is presented and changes in values of harmonic components are analyzed. The effect of higher harmonics on the equipment operation is analyzed.

  3. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  4. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines.

    Science.gov (United States)

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-07-11

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs) as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  5. Potential environmental effects of 765-kV transmission lines: views before the New York State Public Service Commission, Cases 26529 and 26559, 1976-1978

    Energy Technology Data Exchange (ETDEWEB)

    Scott-Walton, B.; Clark, K. M.; Holt, B. R.; Jones, D. C.; Kaplan, S. D.; Krebs, J. S.; Polson, P.; Shepherd, R. A.; Young, J. R.

    1979-11-01

    Testimony given before the New York Public Service Commission in two recent cases on the potential environmental effects of 765-kV overhead ac transmission lines is reviewed. The testimony focused on the potential effects of audible noise, on the potential biological effects of the electromagnetic fields, on the potential for electric shocks to people who touch vehicles parked under the proposed lines, on the potential effects of the electromagnetic fields on electronic cardiac pacemakers, and on potential effects of ozone produced by corona discharge from the lines. The testimony fully explored these questions; however, it did not resolve all of them. The testimony indicates potential impacts from the audible noise and from the electrostatic shocks that people can receive when they touch a large vehicle parked under the lines. The testimony also indicates that certain cardiac pacemaker and lead combinations may, under certain circumstances, undergo reversion to a fixed rate of pacing in the presence of the fields under the lines, but that little risk to cardiac patients results except possibly for those patients for whom competition between the heart's own rate and the pacemaker rate presents a health risk. The testimony fails to demonstrate biological hazards from the field; further research is necessary to understand better the effects of the fields on biological systems. The testimony indicates that ozone produced by the lines will not significantly affect the environment.

  6. Long term investigation of thermal behaviour of 110 kV underground transmission lines in the Belgrade area

    Energy Technology Data Exchange (ETDEWEB)

    Sredojevic, M.R.; Naumov, R.M.; Popovic, D.P. [Nikola Tesla Electrical Engineering Inst., Belgrade (Yugoslavia); Simic, M.D. [Electrical Utility Co., Belgrade (Yugoslavia)

    1997-12-31

    The paper describes the procedure for applying a special cable backfill material, developed and manufactured at the Institute ``Nikola Tesla`` for the thermal stabilisation and reduction of hot spot cable operating temperature, on specific hot spots of 110 kV underground transmission lines in the Belgrade area. The results presented in this paper are an important contribution to the proof of the justification and necessity of defining and introducing in practice new procedures for the thermal stabilisation and reduction of operating temperature of existing, as well as of new, underground transmission cable lines to be built. (author)

  7. Comparing Effects of TCR and TSC on MHO Distance Protection Setting in 400 kV Algerian Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-11-01

    Full Text Available This paper presents a study on the performances of distance relays setting in 400 kV in Eastern Algerian transmission networks at Sonelgaz Group (Algerian company of Electrical and Gas compensated by shunt Flexible AC Transmission System (FACTS. The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations in high power transfer levels. The effects of SVC devices i.e. Thyristor Controlled Reactor (TCR and the Thyristor Switched Capacitors (TSC insertion, on the total impedance of a transmission line protected by MHO distance relay are investigated. The modified setting zones protections for three forward zones (Z1, Z2 and Z3 have been calculated in order to improve the performances of distance relay protection and prevent circuit breaker nuisance tripping.

  8. Assessment of Lightning Shielding Performance of a 400 kV Double-Circuit Fully Composite Transmission Line Pylon

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    -quality insulation sections. Thus, the configuration of phase conductors on the cross-arm is in the form of diagonal and differs from other widely used configurations in overhead transmission lines i.e. horizontal, delta and vertical configurations. Unlike traditional steel lattice towers, the composite pylon does...... not provide access to ground potential due to its non-conductive materials. Therefore, the lightning shielding of pylon and conductors requires a ground potential access to shield wires by utilizing a ground cable inside the hollow cross-arm and pylon body. Efficient design of a lightning shielding system...

  9. Analyzing the Health Risks Resulting from Extending the 400kV High Voltage Transmission Lines on the Human

    Directory of Open Access Journals (Sweden)

    Mohammed Hassan Dervish

    2018-01-01

    Full Text Available Although it is difficult to imagine life without electricity, there are compiling confirmations show thatexposure to magnetic fields correlated electricity and radio frequencies pose magnificent hazards to human health. The most economist method to transfer electricity from power generation stations to users is by measures of high power transmission lines, buoyed by big transmission towers. The cables laced between the towers radiate magnetic and electric fields. In this research study, the magnetic field at ground level under 400 kV network lines extended in residential places have been conducted in two ways, mathematical calculation and practical measurement then the obtained results analyzed and compared with the international standards reference values. the reason of chose this type of transmission line is frequently using. The results indicate that they fall within the safe limiter commended by the WorldHealth Organization. the strength of radiation increasing with high of sea level and moisture ratiobecause of air ionization.

  10. The Reusable Load Cell with Protection Applied for Online Monitoring of Overhead Transmission Lines Based on Fiber Bragg Grating

    Directory of Open Access Journals (Sweden)

    Guoming Ma

    2016-06-01

    Full Text Available Heavy ice coating of high–voltage overhead transmission lines may lead to conductor breakage and tower collapse causing the unexpected interrupt of power supply. The optical load cell applied in ice monitoring systems is immune to electromagnetic interference and has no need of a power supply on site. Therefore, it has become a hot research topic in China and other countries. In this paper, to solve the problem of eccentric load in measurement, we adopt the shearing structure with additional grooves to improve the strain distribution and acquire good repeatability. Then, the fiber Bragg grating (FBG with a permanent weldable package are mounted onto the front/rear groove of the elastic element by spot welding, the direction deviation of FBGs is 90° from each other to achieve temperature compensation without an extra FBG. After that, protection parts are designed to guarantee high sensitivity for a light load condition and industrial safety under a heavy load up to 65 kN. The results of tension experiments indicate that the sensitivity and resolution of the load cell is 0.1285 pm/N and 7.782 N in the conventional measuring range (0–10 kN. Heavy load tension experiments prove that the protection structure works and the sensitivity and resolution are not changed after several high load (65 kN cycles. In addition, the experiment shows that the resolution of the sensor is 87.79 N in the large load range, allowing the parameter to be used in heavy icing monitoring.

  11. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    are interconnected in a simple way but via transformers and infeed from remaining parts of the network. Distance relay measured fault loop impedance shows wide ranges of variations for both phase-phase loops as well as phase-earth loops. No simple relations exist. Simulation models can be used to study fault loop...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...

  12. AC transmission, with very high voltages and the 750 kV line

    Energy Technology Data Exchange (ETDEWEB)

    Bocker, H

    1964-01-01

    The economic case for adoption of extra-high voltages for transmitting electric power over distances of the order of 1000 km is discussed. Some special technical developments for solving the problems attached to such high voltages are briefly discussed, particularly in the fields of switching and transients suppression. The first 750-kV projects in Canada and Russia are mentioned. Equipment, e.g., bushings, transformers, etc., operating at such voltages are illustrated.

  13. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    of the transmission system must be re‐thought in order to accommodate the transmission needs for the future. New lines have to be constructed. Transmission lines are usually laid out as overhead lines, which are large structures, i.e. a 400 kV power pylon is 50 meters high. According to public opinion, such power...

  14. Proposal to amend existing operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, Routt, Jackson and Larimer Counties, Colorado

    International Nuclear Information System (INIS)

    1997-08-01

    The Western Area Power Administration, Rocky Mountain Region, is proposing to amend an existing US Forest Service operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, which are located in Routt, jackson, and Larimer counties, Colorado. These transmission lines cross portions of the Roosevelt and Routt National Forests. The long-term use authorization Western is requesting from the Forest Service would be for the life of the Ault-Craig and Hayden-Archer transmission lines. This environmental assessment addresses those access road and right-of-way maintenance activities identified by Western that would be performed on Forest Service managed lands during the next approximately five years

  15. Proposal to amend existing operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, Routt, Jackson and Larimer Counties, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    The Western Area Power Administration, Rocky Mountain Region, is proposing to amend an existing US Forest Service operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, which are located in Routt, jackson, and Larimer counties, Colorado. These transmission lines cross portions of the Roosevelt and Routt National Forests. The long-term use authorization Western is requesting from the Forest Service would be for the life of the Ault-Craig and Hayden-Archer transmission lines. This environmental assessment addresses those access road and right-of-way maintenance activities identified by Western that would be performed on Forest Service managed lands during the next approximately five years.

  16. A low-latency, low-overhead encoder for data transmission in the ATLAS Liquid Argon Calorimeter trigger upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Le [Department of Physics, Central China Normal University, Wuhan, Hubei 430079 (China); Department of Physics, Southern Methodist University, Dallas, TX 75275 (United States); Li, Xiaoting [Department of Physics, Central China Normal University, Wuhan, Hubei 430079 (China); Gong, Datao, E-mail: dgong@mail.smu.edu [Department of Physics, Southern Methodist University, Dallas, TX 75275 (United States); Chen, Jinghong [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77004 (United States); Deng, Binwei [School of Electric and Electronic Information Engineering, Hubei Polytechnic University, Huangshi, Hubei 435003 (China); Fan, Qingjun; Feng, Yulang [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77004 (United States); Guo, Di [Department of Physics, Southern Methodist University, Dallas, TX 75275 (United States); State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); He, Huiqin [Department of Physics, Central China Normal University, Wuhan, Hubei 430079 (China); Department of Physics, Southern Methodist University, Dallas, TX 75275 (United States); Shenzhen Polytechnic, Shenzhen 518055 (China); Hou, Suen [Institute of Physics, Academia Sinica, Nangang 11529, Taipei, Taiwan (China); Huang, Guangming, E-mail: gmhuang@phy.ccnu.edu.cn [Department of Physics, Central China Normal University, Wuhan, Hubei 430079 (China); Liu, Chonghan; Liu, Tiankuan [Department of Physics, Southern Methodist University, Dallas, TX 75275 (United States); Sun, Xiangming [Department of Physics, Central China Normal University, Wuhan, Hubei 430079 (China); Tang, Yuxuan [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77004 (United States); Teng, Ping-Kun [Institute of Physics, Academia Sinica, Nangang 11529, Taipei, Taiwan (China); and others

    2016-09-21

    In this paper, we present the design and test results of an encoder integrated circuit for the ATLAS Liquid Argon Calorimeter trigger upgrade. The encoder implements a low-latency and low-overhead line code called LOCic. The encoder operates at 320 MHz with a latency of no greater than 21 ns. The overhead of the encoder is 14.3%. The encoder is an important block of the transmitter ASIC LOCx2, which is prototyped with a commercial 0.25 μm Silicon-on-Sapphire CMOS technology and packaged in a 100-pin QFN package. - Highlights: • We present the design and test results of an encoder integrated circuit for the ATLAS Liquid Argon Calorimeter trigger upgrade. • The encoder implements a low-latency and low-overhead line code called LOCic. The encoder operates at 320 MHz with a latency of no greater than 21 ns. The overhead of the encoder is 14.3%. • The encoder is an important block of the transmitter ASIC LOCx2, which is prototyped with a commercial 0.25 μm Silicon-on-Sapphire CMOS technology for radiation-tolerance and packaged in a 100-pin QFN package.

  17. Random Shift and XOR of Unequal-sized Packets (RaSOR) to Shave off Transmission Overhead

    DEFF Research Database (Denmark)

    Taghouti, Maroua; Roetter, Daniel Enrique Lucani; Fitzek, Frank Hanns Paul

    2017-01-01

    We propose the design of a novel coding scheme of unequal-sized packets. Unlike the conventional wisdom that consists of brute-force zero-padding in Random Linear Network Coding (RLNC), we exploit this heterogeneity to shave off this trailing overhead and transmit considerably less coded packets....

  18. Superiority of the practical method to theory: Diagnose of service life of ropes in overhead transmission grids; Praktische Methode der Theorie ueberlegen: Diagnose der Lebensdauer von Freileitungsseilen

    Energy Technology Data Exchange (ETDEWEB)

    Brueckner, W.F.

    2005-02-07

    In designing overhead transmission lines, cable tension is of prior importance. High tension means shorter life unless vibration dampers are installed. On the other hand, higher tension will reduce the overall cost to an optimum level. The author presents experience and measured vibration sensitivities. (orig.) [German] Beim Entwurf von Freileitungen ist die Zugspannung der Seile von besonderer Bedeutung. Erhoehte Seilzugspannungen verringern die Lebensdauer der Seile, soweit die Schwingungsgefahr nicht durch geeignete Schwingungsdaempfer vermieden wird. Mit erhoehter Seilzugspannung verringern sich auch die Kosten der gesamten Freileitung bis zur optimalen Grenze, die von den Kosten je km fuer verschiedene Spannweiten zu bestimmen ist. Der Verfasser beschreibt Erfahrungen ueber die gemessene Schwingungsgefaehrdung der Seile. (orig.)

  19. Thermometer by optical fiber for ampacity studies in overhead transmission lines; Termometro a fibra optica para estudo da ampacidade em linhas de transmissao aereas

    Energy Technology Data Exchange (ETDEWEB)

    Valente, L.C.G.; Kawase, L.R.; Silva Filho, J.I. da; Silva, J.M.M. da [Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, RJ (Brazil); Igarashi, A.Y. [Universidade Federal, Rio de Janeiro, RJ (Brazil)

    1995-12-31

    This article suggests the utilization of thermometers constructed from optical fibers technology in overhead power transmission lines. This will help the studies in progress about the electric power systems ampacity. It also presents the advantages of using optical fibers instead of conventional thermometers. As an example, the fact that the optical fibers are dielectric and make possible the remote monitoring. It is also shown a possibility of introducing such measuring system in electric junctions where OPGW cables are used 4 refs., 4 figs.; e-mail: liliana at fis.puc-rio.br

  20. Maintenance planning for transmission routes with medium voltage overlines - experience within the framework of two pilot projects; Trassenpflegeplanung fuer Mittel- und Hochspannungsfreileitungen - Erfahrungen von zwei Pilotprojekten

    Energy Technology Data Exchange (ETDEWEB)

    Geiges, H. [Ingenieurbuero Geiges, Freiraum- und Landschaftsplanung, Laumersheim (Germany)

    1997-11-03

    On the basis of the `VDEW Orientation Aid for Maintenance Measures in Transmission Routes` two pilot projects were selected in a 110 kV and a 20 kV overhead transmission route. (orig.) [Deutsch] Auf der Grundlage der `VDEW-Orientierungshilfe zu Pflegemassnahmen in Leitungstrassen` wurden Pilotprojekte in einer 110-kV- und in einer 20-kV-Freileitungstrasse im suedlichen Pfaelzerwald ausgewaehlt. (orig.)

  1. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jack M.

    1992-06-01

    Although several kinds of biological effects of electric and magnetic fields have been reported from laboratory studies, few have been independently replicated. When this study was being planned, the suppression of nighttime melatonin in rodents was thought to represent one of the strongest known effects of these fields. The effect had been replicated by a single laboratory for 60-Hz electric fields, and by multiple laboratories for d-c magnetic fields. The primary objective of this study was to determine whether the effect of electric and magnetic fields on melatonin would also occur in sheep exposed to a high voltage transmission line. The specific hypothesis tested by this experiment was as follows: The electrical environment produced by a 60-Hz, 500-kV transmission line causes a depression in nocturnal melatonin in chronically exposed female lambs. This may mimic effects of pinealectomy or constant long-day photoperiods, thus delaying the onset of reproductive cycles. Results of the study do not provide evidence to support the hypothesis. Melatonin concentrations in the sheep exposed to the transmission line showed the normal pattern of low daytime and high nighttime serum levels. As compared to the control group, there were no statistically significant group differences in the mean amplitude, phase, or duration of the nighttime melatonin elevation.

  2. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    Directory of Open Access Journals (Sweden)

    POSTOLATI V.M.

    2010-08-01

    Full Text Available The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL. Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS are formulated. Methodical approaches to the choice of options for transmission lines 220 kV and facilities management are shown.

  3. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-KV Transmission Line

    Science.gov (United States)

    Lee, Jack Monroe, Jr.

    There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations

  4. Complexity Quantification for Overhead Transmission Line Emergency Repair Scheme via a Graph Entropy Method Improved with Petri Net and AHP Weighting Method

    Directory of Open Access Journals (Sweden)

    Jing Zhou

    2014-01-01

    Full Text Available According to the characteristics of emergency repair in overhead transmission line accidents, a complexity quantification method for emergency repair scheme is proposed based on the entropy method in software engineering, which is improved by using group AHP (analytical hierarchical process method and Petri net. Firstly, information structure chart model and process control flowchart model could be built by Petri net. Then impact factors on complexity of emergency repair scheme could be quantified into corresponding entropy values, respectively. Finally, by using group AHP method, weight coefficient of each entropy value would be given before calculating the overall entropy value for the whole emergency repair scheme. By comparing group AHP weighting method with average weighting method, experiment results for the former showed a stronger correlation between quantified entropy values of complexity and the actual consumed time in repair, which indicates that this new method is more valid.

  5. Analysis of behaviour of overhead telecommunications or electric lines illuminated by a nuclear electromagnetic pulse: limitations of use for the transmission line theory

    International Nuclear Information System (INIS)

    Scotto, M.; Jecko, B.

    1987-01-01

    The illumination of overhead lines by a nuclear electromagnetic pulse (NEMP) in presence of a perfectly conducting ground gives rise to a scattering problem leading to phenomena both studied here in time and frequency domains. This problem is resolved with the help of an integral equation established in space-time domain and making possible (without approximation) the determination of the time dependence of the current induced on each point of the wire structure. Moreover, the passage in frequency domain allows to express a transfer function defined in one point of the excited line, pointing out its spectral characteristics. Results clearly show the insufficiency of the classic transmission line theory concealing some phenomena which are described here and for which an interpretation is proposed [fr

  6. Attainment of 40.5 pm spatial resolution using 300 kV scanning transmission electron microscope equipped with fifth-order aberration corrector.

    Science.gov (United States)

    Morishita, Shigeyuki; Ishikawa, Ryo; Kohno, Yuji; Sawada, Hidetaka; Shibata, Naoya; Ikuhara, Yuichi

    2018-02-01

    The achievement of a fine electron probe for high-resolution imaging in scanning transmission electron microscopy requires technological developments, especially in electron optics. For this purpose, we developed a microscope with a fifth-order aberration corrector that operates at 300 kV. The contrast flat region in an experimental Ronchigram, which indicates the aberration-free angle, was expanded to 70 mrad. By using a probe with convergence angle of 40 mrad in the scanning transmission electron microscope at 300 kV, we attained the spatial resolution of 40.5 pm, which is the projected interatomic distance between Ga-Ga atomic columns of GaN observed along [212] direction.

  7. DEVELOPMENT AND INVESTIGATION OF LAYOUT OF ACTIVE SCREENING SYSTEM OF THE MAGNETIC FIELD GENERATED BY GROUP OF OVERHEAD TRANSMISSION LINES

    Directory of Open Access Journals (Sweden)

    B. I. Kuznetsov

    2018-04-01

    Full Text Available Purpose. Development and field experimental research of layout of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area is given. Methodology. Mathematical model of magnetic field, generated by group of high voltage transmission lines in residential area, based of the experimental values of magnetic field flux density in given points on the basis of optimization problem solving is improved. The objective of the synthesis of the single circuit active screening system is to determine their number, configuration, spatial arrangement, wiring diagrams and compensation cables currents, setting algorithm of the control systems as well as the resulting value of the magnetic flux density at the points of the protected space. Synthesis of the full-scale model of active screening system is reduced to the problem of multiobjective nonlinear programming with constraints in which calculation of the objective functions and constraints are carried out on the basis of the Maxwell equations solutions in the quasi-stationary approximation. The problem is solved by a stochastic multiswarm multi-agent particles optimization. Results. The single-circuit active screening system synthesis results for reduction of a magnetic field generated by group of high voltage transmission lines in residential area is given. Field experimental researches of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area with various control algorithms is given. Originality. For the first time out the development and field experimental studies of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area are carried out. Practical value. Practical recommendations on reasonable choice of the spatial arrangement of compensating cables of single

  8. Composite Materials in Overhead Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2009-01-01

    towers and recently conductors based on composite materials are available at transmission levels. In this paper it is investigated which composite based solutions are available in connection with complete overhead line systems including insulators, towers and conductors. The components are reviewed......The use of composite materials, e.g. fibreglass materials, in overhead transmission line systems is nothing new. Composite based insulators have been applied to transmission lines for over 30 years, mainly as suspension and post insulators and often as an option for special applications. Also...... with respect to solved and persisting known failures/problems of both mechanical and electrical nature. Major challenges related to extensive use of composite materials in an overhead line system are identified, as are possible benefits - both when using standard as well as customised composite components, e...

  9. Environmental Assessment and Finding of No Significant Impact: Curecanti-Lost Canyon 230-kV Transmission Line Reroute Project, Montrose County, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-03-20

    The Department of Energy (DOE), Western Area Power Administration (Western) is proposing to reroute a section of the Curecanti-Lost Canyon 230-kilovolt (kV) transmission line, in Montrose County, Colorado. A portion of the transmission line, situated 11 miles southeast of Montrose, Colorado, crosses Waterdog Peak, an area of significant geologic surface activity, which is causing the transmission line's lattice steel towers to shift. This increases stress to structure hardware and conductors, and poses a threat to the integrity of the transmission system. Western proposes to relocate the lattice steel towers and line to a more geologically stable area. The existing section of transmission line and the proposed relocation route cross Bureau of Land Management and private land holdings.

  10. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  11. Remote sensing for industrial applications in the energy business: digital territorial data integration for planning of overhead power transmission lines (OHTLs)

    Science.gov (United States)

    Terrazzino, Alfonso; Volponi, Silvia; Borgogno Mondino, Enrico

    2001-12-01

    An investigation has been carried out, concerning remote sensing techniques, in order to assess their potential application to the energy system business: the most interesting results concern a new approach, based on digital data from remote sensing, to infrastructures with a large territorial distribution: in particular OverHead Transmission Lines, for the high voltage transmission and distribution of electricity on large distances. Remote sensing could in principle be applied to all the phases of the system lifetime, from planning to design, to construction, management, monitoring and maintenance. In this article, a remote sensing based approach is presented, targeted to the line planning: optimization of OHTLs path and layout, according to different parameters (technical, environmental and industrial). Planning new OHTLs is of particular interest in emerging markets, where typically the cartography is missing or available only on low accuracy scale (1:50.000 and lower), often not updated. Multi- spectral images can be used to generate thematic maps of the region of interest for the planning (soil coverage). Digital Elevation Models (DEMs), allow the planners to easily access the morphologic information of the surface. Other auxiliary information from local laws, environmental instances, international (IEC) standards can be integrated in order to perform an accurate optimized path choice and preliminary spotting of the OHTLs. This operation is carried out by an ABB proprietary optimization algorithm: the output is a preliminary path that bests fits the optimization parameters of the line in a life cycle approach.

  12. VT Green Mountain Power Line Data (Overhead Only)

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Green Mountain Power (GMP) pole and OVERHEAD linear distribution/sub-transmission model data. THE LINEAR DISTRIBUTION LAYER ONLY INCLUDES OVERHEAD...

  13. The first 100 Mw Brazil - Argentina interconnection. The design of the 500/525 Kv Rincon de Santa Maria-Garabi-Ita power transmission line; Primeira interconexao 1000 MW Brasil-Argentina. Projeto da LT 500/525 kV Rincon de Santa Maria-Garabi-Ita

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Joao Batista Guimaraes Ferreira da; Guimaraes, Rogerio Peixoto; Menezes, Luciene Oliveira; Amaro, Rania Carla Peixoto [ABB, Belo Horizonte, MG (Brazil)]. E-mail: joao-batista.ferreira@br.abb.com; Silva, Vilson Renato da [Engelineas Consultoria e Projetos Ltda., Porto Alegre, RS (Brazil); Menezes, Ruy Carlos Ramos de [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil); Nolasco, Joao Felix [JFNolasco Consultoria Ltda., Belo Horizonte, MG (Brazil); Bugallo, Francisco [Companhia de Interconexao Energetica (CIEN), Rio de Janeiro, RJ (Brazil)

    2001-07-01

    This document reports the main design aspects and also displays how the implantation challenges had been overcome in relation to the Brazil-Argentina energetic first interconnection, through the frequency converter station in Garabi and the 500 Kv / 50 Hz Rincon de Santa Maria-Garabi transmission line and 500 Kv / 60 Hz Garabi-Ita transmission line, resulting in a total of 490 Kilometers. Firstly, it is presented the basic design characteristics involving the drawing definitions and electrical parameters determination. Afterwards, are presented the transmission line mechanical aspects, as well as the main obtained results. Finally, the project technical viability and the reached benefits had been discussed as well.

  14. Risk assessment of 170 kV GIS connected to combined cable/OHL network

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Kessel, Jakob; Atlason, Vidir

    2009-01-01

    performance, compared to a system consisting solely of AIS connected through overhead lines. The main purpose is to investigate whether overvoltage protection is necessary at the GIS busbar. The analysis is conducted by implementing a simulation model in PSCAD/EMTDC. Simulations are conducted for both SF......This paper concerns different investigations of lightning simulation of a combined 170 kV overhead line/cable connected GIS. This is interesting due to the increasing amount of underground cables and GIS in the Danish transmission system. This creates a different system with respect to lightning...... and BFO. Overvoltages are evaluated for varying front times of the lightning surge, different soil resistivities at the surge arrester grounding in the overhead line/cable transition point and a varying length of the connection cable between the transformer and the GIS busbar with a SA implemented...

  15. Lightning simulation of a combined overhead line/cable connected GIS

    DEFF Research Database (Denmark)

    Kessel, Jakob; Atlason, Vioir; Bak, Claus Leth

    2008-01-01

    performance, compared to a system consisting solely of AIS connected thorugh overhead lines. The main purpose is to investigate whether overvoltage protection is necessary at the GIS busbar. Here, the price for a GIS SA is significantly more expensive than the price for an AIS SA. The analysis is conducted......The paper concerns different investigations of lightning simulation of a combined 170 kV overhead line/cable connected GIS. This is interesting due to the increasing amount of underground cables and GIS in the Danish transmission system. This creates a different system with respect to lightning...... by implementing a simulation model in PSCAD/EMTDC. Simulations are conducted for both SF and BFO where the overvoltage at the transformer are evaluated as this component has the lowest insulation strength. The overvoltages are evaluated for different front imes of the lightning surge, different soil resistivities...

  16. Environmental Assessment for Central Power and Light Company`s proposed Military Highway-CFE tie 138/69-kV transmission line project Brownsville, Cameron County, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    Central Power and Light Company (CPL) intends to upgrade its existing transmission line ties with the Commision Federal de Electricidad (CFE) system in Mexico. CPL currently has a single 69-kilovolt (kV) transmission line in the Brownsville area which connects CPL`s system with the system of CFE. This existing line runs between the Brownsville Switching Station, located on Laredo Road in Brownsville, Cameron County, Texas, and an existing CFE 69-kV line at the Rusteberg Bend of the Rio Grande in Cameron County. Under current conditions of need, the existing 69-kV line does not possess sufficient capability to engage in appropriate power exchanges. Therefore, CPL is proposing to build a new line to link up with CFE. This proposed line would be a double-circuit line, which would (1) continue (on a slightly relocated route) the existing 69-kV tie from CPL`s Brownsville Switching Station to CFE`s facilities, and (2) add a 138-kV tie from the Military Highway Substation, located on Military Highway (US Highway 281), to CFE`s facilities. The proposed 138/69-kV line, which will be constructed and operated by CPL, will be built primarily on steel single-pole structures within an average 60-foot (ft) wide right-of-way (ROW). It will be approximately 6900--9200 ft (1.3--1.7 miles) in length, depending on the alternative route constructed.

  17. Proposed amendment to presidential permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada

    International Nuclear Information System (INIS)

    1992-10-01

    This Addendum to the Final Environmental Assessment for the Proposed Amendment to Presidential Permit PP-63 and Associated Modifications to 500 kV International Transmission Line: Forbes, Minnesota to Manitoba, Canada (DOE/EA-587) addresses Northern States Power Company's (NSP) proposed expansion of the Forbes Substation. The applicant has requested that the expansion take place on the west side of the substation, within the existing property line, instead of on the north side as originally proposed. All of the proposed construction would take place on property already owned by NSP. DOE has reviewed the environmental impacts associated with this minor modification and has determined that the conclusions reached in the environmental assessment and Finding of No Significant Impact prepared in connection with NSP's original amendment request remain valid

  18. A modelling approach for railway overhead line equipment asset management

    OpenAIRE

    Kilsby, Paul; Remenyte-Prescott, Rasa; Andrews, John

    2017-01-01

    The Overhead Line Equipment (OLE) is a critical sub-system of the 25kV AC overhead railway electrification system. If OLE asset management strategies can be evaluated using a whole lifecycle cost analysis that considers degradation processes and maintenance activities of the OLE components, the investment required to deliver the level of performance desired by railway customers and regulators can be based on evidence from the analysis results. A High Level Petri Net (HLPN) model, proposed in ...

  19. A Design of a 345-kV Electric Power Transmission Line Interlinking Ramu and Rouna Grids in Papua New Guinea

    Directory of Open Access Journals (Sweden)

    Sakato Francis

    2017-01-01

    Full Text Available According to PNG Power Limited (PPL, Papua New Guinea’s peak power demand is expected to increase from 210 MW in 2012 to 347 MW in 2026. Under the current state of the power sector in Papua New Guinea (PNG, it is critical to implement measures to cope with the increasing power demand to promote investment, economic growth, and ultimately to achieve poverty reduction through economic growth. One of the solutions identified to improve the reliability of PNG power systems and thus to meet the demand is to interconnect the major grids in the country so that the loads could be shared among them. This project embarks in designing a 345-kV electric power transmission line to interlink the Ramu and Rouna power grids of Papua New Guinea. The design is done by analysing all the necessary aspects of the transmission lines with in-depth calculations performed using MATHCAD software. This design is the basis for extra-high voltage (EHV transmission network in anticipation for the power generation and demand growth in PNG.

  20. Back-to-Back Energization of a 60kV Cable Network - Inrush Currents Phenomenon

    DEFF Research Database (Denmark)

    Faria da Silva, Filipe; Bak, Claus Leth; Hansen, M. Lind

    2010-01-01

    On November 2008 the Danish government decided that all Danish transmission lines with a rated voltage equal to and below 150kV must be put underground, in order to reduce the visual pollution caused by Overhead Lines. This decision will lead to a massive use of underground cables in the Danish...... Network, and force a change in the approach used until now when planning, analyzing and operating electrical power systems. One problem that might arise is the energization of cables in parallel, as this operation may originate high inrush currents, which represent a risk to the circuit breakers connected...

  1. Overhead Crane Computer Model

    Science.gov (United States)

    Enin, S. S.; Omelchenko, E. Y.; Fomin, N. V.; Beliy, A. V.

    2018-03-01

    The paper has a description of a computer model of an overhead crane system. The designed overhead crane system consists of hoisting, trolley and crane mechanisms as well as a payload two-axis system. With the help of the differential equation of specified mechanisms movement derived through Lagrange equation of the II kind, it is possible to build an overhead crane computer model. The computer model was obtained using Matlab software. Transients of coordinate, linear speed and motor torque of trolley and crane mechanism systems were simulated. In addition, transients of payload swaying were obtained with respect to the vertical axis. A trajectory of the trolley mechanism with simultaneous operation with the crane mechanism is represented in the paper as well as a two-axis trajectory of payload. The designed computer model of an overhead crane is a great means for studying positioning control and anti-sway control systems.

  2. Overhead distribution line models for harmonics studies

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, M.; Xu, W.; Dommel, H.W.

    1994-01-01

    Carson's formulae and Maxwell's potential coefficients are used for calculating the per unit length series impedances and shunt capacitances of the overhead lines. The per unit length values are then used for building the models, nominal pi-circuit, and equivalent pi-circuit at the harmonic frequencies. This paper studies the accuracy of these models for presenting the overhead distribution lines in steady-state harmonic solutions at frequencies up to 5 kHz. The models are verified with a field test on a 25 kV distribution line and the sensitivity of the models to ground resistivity, skin effect, and multiple grounding is reported.

  3. B. C. Hydro proposed 287 kV transmission line Kitimat to Terrace: Preliminary environmental assessment of fish and wildlife values

    Energy Technology Data Exchange (ETDEWEB)

    Hazelwood, W G

    1991-01-01

    The proposed two corridors for an additional 278 kV transmission line from Terrace to Kitimat, British Columbia were referenced for fisheries and wildlife sensitivity and impact. Route A parallels the existing powerline down the eastern edge of the Kitimat valley while Route B follows the western edge and is 12 km shorter. Fisheries values are paramount in the study area with populations of steelhead, pink, coho, chinook, chum and sockeye in both the Lakelse and Kitimat drainages. Recreational species are of strong secondary importance and support a viable tourist industry. Wildlife values are best represented by moose, bear, fur-bearers and waterfowl. Clearcut logging has depressed populations in the study area but regrowth of essential habitat and cover is allowing some species to increase in number. Trumpeter swans utilize the valley as a migration route while some remain as residents in warmer winters. The two proposed corridors were evaluated on a resource basis to determine the least impactive and sensitive route, with a general rating evolved with common criteria. The rating of Route B was significantly less sensitive than Route A, due to Route B being significantly shorter and drier. 2 figs.

  4. Electric power transmission for a Hanford Nuclear Energy Center (HNEC)

    International Nuclear Information System (INIS)

    1975-09-01

    The major issues examined in the comparison of the DIST and HNEC transmission concepts are: (1) type of transmission to be employed and an assessment of its technical feasibility, (2) availability of rights-of-way, (3) economics, (4) environmental impact, and (5) overall reliability of the transmission system. The type of transmission selected for bulk power transfer from an HNEC for the time period studied is overhead AC, 500 kV double or single circuit, a voltage currently used in the PNW system. This type of system can accommodate growth up to at least 23,000 MW of thermal capacity at an HNEC. Significant additional transmountain capacity needs would require 1100 kV transmission, which should be technologically proved by the end of the 1970s. (auth)

  5. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  6. Comparison of overhead line lightning performance based on two different tower geometries

    DEFF Research Database (Denmark)

    Ebdrup, Thomas; Olason, Daniel; Bak, Claus Leth

    2014-01-01

    of the substation and transmission line is of great importance as it is a part of the 400 kV backbone between Sweden, Norway, Germany and the offshore wind farms in Horns Rev, Denmark. The new Eagle pylon has been designed with the focus of minimizing the visual impacted of overhead lines. A detailed lightning...... performance analysis of the existing Donau and the new Eagle pylon is therefore important in order to assess the risk of failure. The lightning strike analysis is based on the number of strikes expected to terminate on the line and an investigation of how many of these there may be expected to cause...... better protected from direct stroke than the phase conductors on the Donau pylon. Furthermore with respect to a backflash, the Eagle has a better performance than the Donau pylon. It is therefore concluded that the Eagle has a better lightning performance than the Donau....

  7. Obstacle negotiation control for a mobile robot suspended on overhead ground wires by optoelectronic sensors

    Science.gov (United States)

    Zheng, Li; Yi, Ruan

    2009-11-01

    Power line inspection and maintenance already benefit from developments in mobile robotics. This paper presents mobile robots capable of crossing obstacles on overhead ground wires. A teleoperated robot realizes inspection and maintenance tasks on power transmission line equipment. The inspection robot is driven by 11 motor with two arms, two wheels and two claws. The inspection robot is designed to realize the function of observation, grasp, walk, rolling, turn, rise, and decline. This paper is oriented toward 100% reliable obstacle detection and identification, and sensor fusion to increase the autonomy level. An embedded computer based on PC/104 bus is chosen as the core of control system. Visible light camera and thermal infrared Camera are both installed in a programmable pan-and-tilt camera (PPTC) unit. High-quality visual feedback rapidly becomes crucial for human-in-the-loop control and effective teleoperation. The communication system between the robot and the ground station is based on Mesh wireless networks by 700 MHz bands. An expert system programmed with Visual C++ is developed to implement the automatic control. Optoelectronic laser sensors and laser range scanner were installed in robot for obstacle-navigation control to grasp the overhead ground wires. A novel prototype with careful considerations on mobility was designed to inspect the 500KV power transmission lines. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  8. French 400 kV network

    Energy Technology Data Exchange (ETDEWEB)

    Pelissier, R

    1965-11-01

    A 400 kV transmission network has been constructed to carry hydroelectric power from the Alps and the Massif Central to Paris at peak hours and to carry power in the reverse direction in off-peak hours. A double circuit-ring at 400 kV encircling the Paris region is also nearing completion. Measures have to be taken to counter the very high short-circuit currents in such a network. A 730 kV network will eventually become necessary. The consequent multiplicity of transmission voltages will give rise to further problems. Collaboration with neighboring countries is envisaged. The problems of stability and synchronization posed by the new system are described and solutions suggested. The new circuit-breaking requirements are discussed, and details of tower design for 400 kV and 730 kV are given.

  9. A Study of Electromagnetic Radiation of Corona Discharge Near 500-Kv Electric Installations

    International Nuclear Information System (INIS)

    Korzhov, A. V.; Okrainskaya, I. S.; Sidorov, A. I.; Kufel'd, V. D.

    2004-01-01

    Data on the spectral composition and intensity of electromagnetic radiation of corona discharge are obtained in an experimental study performed on the outdoor switchgear of the Shagol 500-kV substation of the Chelyabinsk Enterprise of Trunk Transmission Grids and under a 500-kV Shagol - Kozyrevo overhead transmission line. The electromagnetic environment on the territory of the 500-kV outdoor switchgear is shown to be determined by narrow-band radiations (harmonics of the frequency of electric supply) and wide-band radiations due to corona discharges of high-voltage sources. This means that the personnel experience the action of a commercial-frequency electric field and electromagnetic radiation of a quite wide range, which is not allowed for by the existing guidelines. It is recommended to continue the study in cooperation with medical institutions in order to create guidelines that would allow for the joint action of commercial-frequency electric field and electromagnetic radiation and for the voltage in the line, the current load, the meteorological situation, and other factors

  10. Snow accretion on overhead wires

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Y. [Meteorological Research Inst. for Technology Co. Ltd., Tokyo (Japan); Tachizaki, S.; Sudo, N. [Tohoku Electric Power Co. Ltd., Miyagi (Japan)

    2005-07-01

    Wet snow accretion can cause extensive damage to transmission systems. This paper reviewed some of the difficulties faced by researchers in the study of wet snow accretion on overhead lines in Japan. The study of snow accretion phenomena is complicated by the range of phase changes in water. Snowflakes produced in an upper atmospheric layer with a temperature below freezing do not melt when they go through a lower atmospheric layer with a temperature above freezing, but are in a mixed state of solid and liquid due to the latent heat of melting. The complicated properties of water make studies of snow accretion difficult, as well as the fact that snow changes its physical properties rapidly, due to the effects of ambient temperature, rainfall, and solar radiation. The adhesive forces that cause snow accretion include freezing; bonding through freezing; sintering; condensation and freezing of vapor in the air; mechanical intertwining of snowflakes; capillary action due to liquids; coherent forces between ice particles and water formed through the metamorphosis of snowflakes. In addition to these complexities, differences in laboratory room environments and natural snow environments can also pose difficulties for researchers. Equations describing the relationship between the density of accreted snow and the meteorological parameters involved were presented, as well as empirical equations which suggested that snow accretion efficiency has a dependency on air temperature. An empirical model for estimating snow loads in Japan was outlined, as well as various experiments observing show shedding. Correlations for wet snow accretion included precipitation intensity; duration of precipitation; air temperature; wind speed and wind direction in relation to the overhead line. Issues concerning topography and wet snow accretion were reviewed. It was concluded that studies of snow accretion will benefit by the collection of data in each matrix of the relevant parameters. 12 refs

  11. Rugi Daya Dan Energi Akibat Korona Pada Saluran Udara Tegangan Ekstra Tinggi (SUTET 500 Kv

    Directory of Open Access Journals (Sweden)

    Muhamad Haddin

    2018-01-01

    Full Text Available The use of extra high voltage in electrical power transmission system causing corona. A visual corona phenomenon shown by the appearance of visible light radiation, hissing noise, ozone formation and power losses. The impact of corona affect the environment surrounding the overhead line transmission and power losses in the line. This research discusses power and energy losses due to corona by using quantitative method. Calculations performed by calculating relative air density values, disruptive critical voltages, power losses and corona energy. The research object was taken by extra high voltage  overhead line transmission 500kV Tanjung Jati B Power Plant to Ungaran Substation.The result show that corona power losses are 0.41-0.44 kW/mil (0.25-0.27kw/km per phase, with total 1.25-1.30kW/mil (0.78-0.81k/w/km. corona power losses 107.57-112.08 kW along of line. Average of corona energy losses obtained 2642.67 kWh. The percentage of corona power losses to electrical power supplied is between 0.005% to 0.011%.

  12. Using ice melting and ice rolling technologies to remove ice from sub-transmission and transmission lines at Manitoba Hydro

    International Nuclear Information System (INIS)

    Farias, A. R.

    1999-01-01

    Development of an of an Ice Storm Management program by Manitoba Hydro to reduce ice storm damage to its 8 kV feeders to 115 kV transmission lines, is discussed. The program consists of the de-icing of overhead lines, either by ice melting, or ice rolling. Ice melting involves the placement of a three-phase short at a calculated point. The term ice rolling denotes a process of mechanically stripping the ice from conductors. The most recent major ice storm experienced by Manitoba Hydro was in the winter of 1997/1998. During the period from February 6 to February 17, 1998, a total of 83 'ice melt' procedures were performed to melt the ice from 2,628 km of overhead line (7,883 km of conductor), in addition to 'ice rolling'. This paper describes Manitoba Hydro's 25-years' experience with ice melting and it also describes the advantages and disadvantages of both ice melting and ice rolling. Although not a panacea to combat the effects of ice storms, ice melting was found to be the most effective way of removing ice from overhead transmission and sub-transmission lines. Ice rolling was also found to be effective. Other tools that have been found to be useful by various utilities in combating ice storm damage include improved structure and line design, system design that provide more redundancies and emergency sources, and standby generators at critical load points

  13. First multivendor scheme in CFE to protection of 400 kV transmission line, using optical TC's, digital relays and bus IEC 61850-9-2; Primer esquema multivendedor en CFE para proteccion de linea de transmision de 400 kV, utilizando TC's opticos, relevadores digitales y bus IEC 61850-9-2

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Colon, V.R; Rasgado, J.P [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Lara C, H; Melendez, C; Juarez, N [Subdireccion de Transmision, Comision Federal de Electricidad (Mexico)

    2013-03-15

    This paper presents the details of design, installation and putting into service in the Comision Federal de Electricidad (CFE), of the first multi-vendor scheme that exists in the world, for the protection of a 400kV transmission line, which uses optical current transformers and digital relays IEC 61850-9-2. This system arises as a pilot project of the Subdireccion de Transmision of the CFE with the Instituto de Investigaciones Electricas (IIE). To ensure success in the implementation of the protection scheme, CFE joined a team coordinated by the Instituto de Investigaciones Electricas (IIE)involving nine international companies and a university. Pilot protection scheme is in operation under continuous monitoring, in one of the transmission lines of CFE that interconnect Manuel Moreno Torres with El Juile substations. The construction features, the challenges that were overcome and the first results obtained in operation are presented below. [Spanish] Este articulo presenta los detalles del diseno, instalacion y puesta en servicio en la Comision Federal de Electricidad (CFE) del primer esquema multivendedor que existe en el mundo, para la proteccion de una linea de transmision de 400kV, que utiliza transformadores de corriente opticos y relevadores digitales IEC 61850-9-2. Este sistema surge como un proyecto piloto de la Subdireccion de Transmision de la CFE con el Instituto de Investigaciones Electricas (IIE). Para asegurar el exito en la implementacion del esquema de proteccion, la CFE integro un equipo de trabajo coordinado por el Instituto de Investigaciones Electricas (IIE) en el que participaron 9 empresas internacionales y una universidad. El esquema de proteccion piloto, se encuentra en operacion bajo monitoreo continuo, en una de las lineas de transmision de la CFE que interconecta las subestaciones de Manuel Moreno Torres y El Juile. Las caracteristicas de construccion, los retos que fueron vencidos y los primeros resultados obtenidos en su operacion se

  14. Technical and economic feasibility of superconducting power transmission: a case study

    International Nuclear Information System (INIS)

    Forsyth, E.B.; Mulligan, G.A.; Beck, J.W.; Williams, J.A.

    1975-01-01

    The long-range plans of the Long Island Lighting Company include the installation of 4600 MW of generation capacity at nuclear sites on eastern Long Island by the 1990's. A single site, Shoreham, was chosen for this study which would require transmission facilities to the Ruland Road substation, 43 miles away. Conventional 345 kV overhead and underground circuits are planned for this service. For the case study three superconducting cable schemes have been investigated which reflect various technical options. The superconducting cables have been designed to meet acceptable normal and contingency load flow conditions and to withstand maximum short circuit faults. A cost analysis has been made of the complete installation, providing a valuable comparison of the estimated cost of this new technology with conventional methods. The most favorable cost comparison is a two-circuit 345 kV superconducting system, which appears to be about one-half the cost of an all underground 345 kV high pressure oil-filled cable system. No reactive compensation will be required for the superconducting system, whereas extensive compensation is required for HPOF cables over the same distance. The cost estimate for the two-circuit superconducting system is about twice that of 345 kV overhead transmission, which would consist of two double circuits and one single circuit, assuming right-of-way could be obtained. (U.S.)

  15. Draft environmental impact statement for construction and operation of the proposed Bangor Hydro-Electric Company`s second 345-kV transmission tie line to New Brunswick

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-10-01

    This Draft Environmental Impact Statement (DEIS) was prepared by the US Department of Energy (US DOE). The proposed action is the issuance of Presidential Permit PP-89 by DOE to Bangor Hydro-Electric Company to construct and operate a new international transmission line interconnection to New Brunswick, Canada that would consist of an 83.8 mile (US portion), 345-kilovolt (kV) alternating current transmission line from the US-Canadian border at Baileyville, Maine to an existing substation at Orrington, Maine. The principal environmental impacts of the construction and operation of the transmission line would be incremental in nature and would include the conversion of forested uplands (mostly commercial timberlands) and wetlands to right-of-way (small trees, shrubs, and herbaceous vegetation). The proposed line would also result in localized minor to moderate visual impacts and would contribute a minor incremental increase in the exposure of some individuals to electromagnetic fields. This DEIS documents the purpose and need for the proposed action, describes the proposed action and alternatives considered and provides a comparison of the proposed and alternatives routes, and provides detailed information on analyses of the environmental consequences of the proposed action and alternatives, as well as mitigative measures to minimize impacts.

  16. El Paso Electric Company Diablo Substation to the US-Mexico border 115kV transmission line project. Final Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    This Environmental Assessment documents the analysis of alternative corridors for development and operation of a proposed 115 kilovolt transmission line using private lands and transporting power to the US-Mexico international border. The project will require (1) an amendment to El Paso Electric Company`s existing export authorization to transfer power across this border, and (2) a Presidential Permit for construction of the transmission line. The project would be located in Dona Ana county in southern New Mexico, approximately five miles west of El Paso, Texas. The alternative corridors, specific locations within those corridors, and structure types are identified and analyzed in the environmental studies.

  17. Shoulder injuries in overhead sports

    International Nuclear Information System (INIS)

    Woertler, K.

    2010-01-01

    Overhead sport places great demands on the shoulder joint. Shoulder pain in overhead athletes and throwers can in the majority of cases be attributed to lesions resulting from chronic overuse of tendons and capsuloligamentous structures or to sequels of microinstability and secondary impingement. Due to its great impact on therapeutic decisions, imaging in athletes with unclear shoulder pain is a challenge. In this connection, magnetic resonance (MR) arthrography represents the cross-sectional imaging modality of first choice, as it allows depiction and exclusion of pathologic alterations of all relevant joint structures with sufficient confidence. This article reviews the biomechanical and clinical aspects and MR arthrographic features of the most common shoulder pathologies in overhead athletes, including biceps tendinopathy, superior labral anterior-posterior (SLAP) lesions, rotator cuff lesions, as well as extrinsic and intrinsic impingement syndromes. (orig.) [de

  18. [Shoulder injuries in overhead sports].

    Science.gov (United States)

    Wörtler, K

    2010-05-01

    Overhead sport places great demands on the shoulder joint. Shoulder pain in overhead athletes and throwers can in the majority of cases be attributed to lesions resulting from chronic overuse of tendons and capsuloligamentous structures or to sequels of microinstability and secondary impingement. Due to its great impact on therapeutic decisions, imaging in athletes with unclear shoulder pain is a challenge. In this connection, magnetic resonance (MR) arthrography represents the cross-sectional imaging modality of first choice, as it allows depiction and exclusion of pathologic alterations of all relevant joint structures with sufficient confidence.This article reviews the biomechanical and clinical aspects and MR arthrographic features of the most common shoulder pathologies in overhead athletes, including biceps tendinopathy, superior labral anterior-posterior (SLAP) lesions, rotator cuff lesions, as well as extrinsic and intrinsic impingement syndromes.

  19. Wireless overhead line temperature sensor based on RF cavity resonance

    International Nuclear Information System (INIS)

    Ghafourian, Maryam; Nezhad, Abolghasem Zeidaabadi; Bridges, Greg E; Thomson, Douglas J

    2013-01-01

    The importance of maximizing power transfer through overhead transmission lines necessitates the use of dynamic power control to keep transmission line temperatures within acceptable limits. Excessive conductor operating temperatures lead to an increased sag of the transmission line conductor and may reduce their expected life. In this paper, a passive wireless sensor based on a resonant radio frequency (RF) cavity is presented which can be used to measure overhead transmission line temperature. The temperature sensor does not require a power supply and can be easily clamped to the power line with an antenna attached. Changing temperature causes a change of cavity dimensions and a shift in resonant frequency. The resonant frequency of the cavity can be interrogated wirelessly. This temperature sensor has a resolution of 0.07 °C and can be interrogated from distances greater than 4.5 m. The sensor has a deviation from linearity of less than 2 °C. (paper)

  20. APPLICATION OF SSSC TO THE 330kV NIGERIAN ...

    African Journals Online (AJOL)

    HOD

    2,3 DEPARTMENT OF ELECTRONIC AND ELECTRICAL ENGR., FEDERAL POLYTECHNIC EDE, ... Longitudinal power systems of Nigerian 330 kV transmission network have steady-state ..... C tr ller ” Unpublish Master Thesis Submitted to.

  1. Transmission line undergrounding : rate impact investigation and analysis

    International Nuclear Information System (INIS)

    2004-01-01

    In response to concerns expressed by the residents of Markham, Ontario regarding the possible environmental and health impacts of a proposed 230 kV overhead transmission line, Hydro One Networks Inc. (HONI) has proposed to place the line underground as an alternative. This analysis was prepared to evaluate the potential impacts on transmission rates and consumer prices related to changes in the level of underground construction of transmission lines by HONI, as opposed to overhead construction. The report presents the approach to data collection; cost estimates and projections; the modeling and projecting of HONI's regulated rate base and revenue requirement on a basis that reflects the manner in which its future transmission rates are expected to be established; estimates of the incremental cost of undergrounding reflecting a range of reasonable assumptions; and a comparison of the resulting transmission costs and total customer bill. To address the issue of potential demand in other municipalities for additional undergrounding, the study also examined the cumulative effects of ten years' incremental undergrounding costs (i.e. effects on 2014 rates). It was concluded that if HONI were to implement an undergrounding program beginning in 2005, resulting in the installation of 80 km of underground lines by 2014, and shared costs by all users of HONI's system through the network transmission charges, the 2014 transmission rates would be higher. 5 tabs

  2. Lightning Performance on Overhead Distribution Lines : After Improvement Field Observation

    Directory of Open Access Journals (Sweden)

    Reynaldo Zoro

    2009-11-01

    Full Text Available Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system. These two feeders used the new overhead ground wire and new line arrester equipped with lightning counter on the main lines. The significant reduced of lines outages are reported. Study was carried out to observe these improvements by comparing to the other two feeders line which are not improved and not equipped yet with the ground wire and line arrester. These two feeders located in the nearby area. Two cameras were installed to record the trajectory of the lightning strikes on the improved lines. Lightning peak currents are measured using magnetic tape measurement system installed on the grounding lead of lightning arrester. Lightning overvoltage calculations are carried out by using several scenarios based on observation results and historical lightning data derived from lightning detection network. Lightning overvoltages caused by indirect or direct strikes are analyzed to get the lightning performance of the lines. The best scenario was chosen and performance of the lines were improved significantly by installing overhead ground wire and improvement of lightning arrester installation.

  3. Analysis on the Operation Strategy of the 220kV External Transmission Channel for the Nujiang Power Grid after the Installation of Series Compensation

    Science.gov (United States)

    Liu, Xiaoxin; Feng, Peilei; Jan, Lisheng; Dai, Xiaozhong; Cai, Pengcheng

    2018-01-01

    In recent years, Nujiang Prefecture vigorously develop hydropower, the grid structure in the northwest of Yunnan Province is not perfect, which leads to the research and construction of the power grid lags behind the development of the hydropower. In 2015, the company in view of the nu river hydropower dilemma decided to change outside the nu river to send out a passage with series compensation device in order to improve the transmission capacity, the company to the main problems related to the system plan, but not too much in the region distribution network and detailed study. Nujiang power grid has unique structure and properties of the nujiang power grid after respectively, a whole rack respectively into two parts, namely power delivery channels, load power supply, the whole grid occurred fundamental changes, the original strategy of power network is not applicable, especially noteworthy is the main failure after network of independent operation problem, how to avoid the local series, emergency problem is more urgent, very tolerance test area power grid, this paper aims at the analysis of existing data, simulation, provide a reference for respectively after the operation for the stable operation of the power grid.

  4. KV7 potassium channels

    DEFF Research Database (Denmark)

    Stott, Jennifer B; Jepps, Thomas Andrew; Greenwood, Iain A

    2014-01-01

    Potassium channels are key regulators of smooth muscle tone, with increases in activity resulting in hyperpolarisation of the cell membrane, which acts to oppose vasoconstriction. Several potassium channels exist within smooth muscle, but the KV7 family of voltage-gated potassium channels have been...

  5. Switching overvoltage when disconnecting a combined 400 kVcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    400 kV power system and initiated by Danish TSO Energinet.dk after having measured the voltage of the cable/overhead line after disconnection. A particular decaying dynamic phase voltage containing voltages higher than the voltage before disconnection appeared. A simulation model for the entire system...

  6. Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2005-01-01

    Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

  7. Electric transmission technology

    International Nuclear Information System (INIS)

    Shah, K.R.

    1990-01-01

    Electric transmission technology has matured and can transmit bulk power more reliably and economically than the technology 10 years ago.In 1882, Marcel Depres transmitted 15 kW electric power at 2 kV, using a constant direct current; present transmission voltages have risen to ± 600 kV direct current (DC) and 765 kV alternating current (AC), and it is now possible to transmit bulk electric power at voltages as high as ± 1000 kV DC and 1500 kV AC. Affordable computer systems are now available to optimize transmission reliably. New materials have reduced the bulk of insulation for lines and equipment. New conducting materials and configurations have reduced losses in transmission. Advances in line structures and conductor motion, understanding of flashover characteristics of insulators and air-gaps and electrical performance of lines have resulted in more compact urban transmission lines. (author). 15 refs., 7 tabs., 11 figs

  8. Retrofit curtain for overhead doors

    Energy Technology Data Exchange (ETDEWEB)

    Leckie, R E

    1987-12-29

    A heat insulating curtain has been developed for reducing heat losses through overhead doors of the type commonly found in industrial warehouses. The curtain consists of a reinforced polyester fabric attached to the outside top of the overhead door and moves with the door as it opens and closes. A T-shaped edge track seals the edges of the curtain to the door frame; the edge of the curtain is also T-shaped and runs up and down the track as the curtain is raised and lowered. The curtain fabric is ultraviolet resistant, durable, flexible, and transparent, and transforms the door into a solar collector which provides solar heated air to the building interior. Two curtains have been satisfactorily installed and tested at a warehouse in Calgary, Alberta. A market evaluation study was conducted to determine the possible buyers for such a door curtain. A target market consisting of those wishing to fix old, leaky doors was selected and a marketing strategy developed. The described strategy includes product development, pricing, distribution, promotion, and advertising. 2 figs., 1 tab.

  9. The fallacy of the overhead quick fix.

    Science.gov (United States)

    Blaxill, M F; Hout, T M

    1991-01-01

    Facing pressure from a few large, low-cost competitors, Thornton, an old-guard specialty-equipment manufacturer, fought back by eliminating overhead. Over two-years, it outsourced components and consolidated operations. But instead of cutting overhead, it added more and became still more uncompetitive. Thornton is not alone in either its predicament or its failed reaction. Many large manufacturing companies are finding themselves at a cost disadvantage in markets they have dominated for years. One reason is excessive overhead structures, the result of an unchecked buildup of indirect employees needed to control rising organizational complexity. Another reason is the emergence of the "robust" competitor, comparable in size and product scope but able to produce at a lower unit overhead cost. Data collected from more than 100 manufacturing plants worldwide illustrate the differences between overhead cost structures of bureaucratic, niche, and robust companies. The gulf between these groups highlights the need for action by bureaucratic companies, and, in some cases, by niche companies. But high-overhead companies are doomed if they cut overhead out of the system either by outsourcing or downsizing. If they expect to retain their size and also become more cost competitive, they must rethink their manufacturing systems. Well-designed and well-controlled processes mean higher product quality, faster cycle time, improved flexibility, and lower overhead costs. Sustainable overhead reduction means a commitment to continuous improvement. This includes segmenting, mapping, and measuring existing processes and then working to improve them.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Concept design of the high voltage transmission system for the collider tunnel

    International Nuclear Information System (INIS)

    Norman, L.S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations -- such as the Channel Tunnel -- demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design

  11. Concept design of the high-voltage transmission system for the collider tunnel

    International Nuclear Information System (INIS)

    Norman, L.S.

    1992-01-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations-such as the Channel Tunnel-demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design

  12. Enhancing the reliability of AC transmission networks by using a long distance HVDC-link

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Marco; Balzer, Gerd; Wasserrab, Andreas; Neumann, Claus [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    The absorption of energy from offshore wind farms is a difficult task for Transmission system operators (TSO) in Germany, even if no offshore wind farm is connected directly. The role of the TSOs in the north it is to transport this energy to the south of Germany. The transmission capacities of overhead lines are limited. With the expected rapid expansion of wind farms, this is no longer enough. Thus, the transmission system must be enhanced. One possibility is the installation of an HVDC link from north to south between two main substations in the 380 kV network. Based on a realistic case study, the impact of such a link on the reliability of the entire extra high voltage network is shown. (orig.)

  13. Decision and Order in the matter of an application by Superior Wind Prince Power Inc. for an Order or Orders pursuant to section 92 of the Ontario Energy Board Act, 1998 granting leave to construct a 230 kV transmission line and associated facilities to connect a proposed 99 MW wind farm to the transmission system of Great Lakes Power Ltd. near Sault Ste Marie[In the matter of the Ontario Energy Board Act, 1998, S.O. 1998, c. 15, Schedule B

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, G.; Betts, B.; Vlahos, P.

    2005-07-28

    Superior Wind Prince Power Inc. plans to construct and operate a 99 MW wind generation facility near Sault Ste. Marie, Ontario. It has also filed an application with the Ontario Energy Board to construct transmission facilities to connect the wind farm to the transmission system of Great Lakes Power Ltd. This includes a substation with a 34.5/230 kV transformer, a high voltage breaker, and low voltage switchgear. It also includes an 11.2 km long, 230 kV transmission line and a switching station with a 230 kV breaker and related facilities. The entire project is scheduled for completion by March, 2006. The Board will proceed with the application by way of a written hearing. This document presents evidence of the applicant with reference to the request for proposals for 300 MW of Renewable Energy. The wind farm includes 66 wind turbine generators providing an output of 99 MW. Plans for a second phase would add 101 MW to the wind farm. Different high voltage and low voltage configurations have been examined on the basis of environmental and economic considerations and system reliability. The best configuration was a 34.5 kV underground collector system and a 230 kV above ground transmission line. Four alternative routes for the line were examined on the basis of environmental, technical and economic factors. This document also provided evidence of PUC Distribution Inc. and addressed issues regarding a system impact assessment, customer impact assessment, and environmental assessment. The Board questioned whether the project is needed, what impact it will have on transmission rates, and reliability of supply. It also examined if all land-use matters have been addressed. The Board approved the project subject to certain conditions regarding communications, monitoring and reporting requirements. 2 refs., 1 appendix.

  14. work specification for the construction of 33kv overhead lines across

    African Journals Online (AJOL)

    HOD

    obtained using the standard mathematical equations and the specifications for Aluminium Conductor Steel Reinforce ... systems. The choice of conductor depends on the cost and efficiency. ... Support structure requirements, limitations.

  15. Low voltage 80 KV to 125 KV electron processors

    International Nuclear Information System (INIS)

    Lauppi, U.V.

    1999-01-01

    The classic electron beam technology made use of accelerating energies in the voltage range of 300 to 800 kV. The first EB processors - built for the curing of coatings - operated at 300 kV. The products to be treated were thicker than a simple layer of coating with thicknesses up to 100g and more. It was only in the beginning of the 1970's that industrial EB processors with accelerating voltages below 300 kV appeared on the market. Our company developed the first commercial electron accelerator without a beam scanner. The new EB machine featured a linear cathode, emitting a shower or 'curtain' of electrons over the full width of the product. These units were much smaller than anv previous EB processors and dedicated to the curing of coatings and other thin layers. ESI's first EB units operated with accelerating voltages between 150 and 200 kV. In 1993 ESI announced the introduction of a new generation of Electrocure. EB processors operating at 120 kV, and in 1998, at the RadTech North America '98 Conference in Chicago, the introduction of an 80 kV electron beam processor under the designation Microbeam LV

  16. Variance analysis refines overhead cost control.

    Science.gov (United States)

    Cooper, J C; Suver, J D

    1992-02-01

    Many healthcare organizations may not fully realize the benefits of standard cost accounting techniques because they fail to routinely report volume variances in their internal reports. If overhead allocation is routinely reported on internal reports, managers can determine whether billing remains current or lost charges occur. Healthcare organizations' use of standard costing techniques can lead to more realistic performance measurements and information system improvements that alert management to losses from unrecovered overhead in time for corrective action.

  17. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A. [New York Power Authority, White Plains, NY (United States)

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  18. Mechanosensitive gating of Kv channels.

    Directory of Open Access Journals (Sweden)

    Catherine E Morris

    Full Text Available K-selective voltage-gated channels (Kv are multi-conformation bilayer-embedded proteins whose mechanosensitive (MS Popen(V implies that at least one conformational transition requires the restructuring of the channel-bilayer interface. Unlike Morris and colleagues, who attributed MS-Kv responses to a cooperative V-dependent closed-closed expansion↔compaction transition near the open state, Mackinnon and colleagues invoke expansion during a V-independent closed↔open transition. With increasing membrane tension, they suggest, the closed↔open equilibrium constant, L, can increase >100-fold, thereby taking steady-state Popen from 0→1; "exquisite sensitivity to small…mechanical perturbations", they state, makes a Kv "as much a mechanosensitive…as…a voltage-dependent channel". Devised to explain successive gK(V curves in excised patches where tension spontaneously increased until lysis, their L-based model falters in part because of an overlooked IK feature; with recovery from slow inactivation factored in, their g(V datasets are fully explained by the earlier model (a MS V-dependent closed-closed transition, invariant L≥4. An L-based MS-Kv predicts neither known Kv time courses nor the distinctive MS responses of Kv-ILT. It predicts Kv densities (hence gating charge per V-sensor several-fold different from established values. If opening depended on elevated tension (L-based model, standard gK(V operation would be compromised by animal cells' membrane flaccidity. A MS V-dependent transition is, by contrast, unproblematic on all counts. Since these issues bear directly on recent findings that mechanically-modulated Kv channels subtly tune pain-related excitability in peripheral mechanoreceptor neurons we undertook excitability modeling (evoked action potentials. Kvs with MS V-dependent closed-closed transitions produce nuanced mechanically-modulated excitability whereas an L-based MS-Kv yields extreme, possibly excessive

  19. Overhead-Aware-Best-Fit (OABF) Resource Allocation Algorithm for Minimizing VM Launching Overhead

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao [IIT; Garzoglio, Gabriele [Fermilab; Ren, Shangping [IIT, Chicago; Timm, Steven [Fermilab; Noh, Seo Young [KISTI, Daejeon

    2014-11-11

    FermiCloud is a private cloud developed in Fermi National Accelerator Laboratory to provide elastic and on-demand resources for different scientific research experiments. The design goal of the FermiCloud is to automatically allocate resources for different scientific applications so that the QoS required by these applications is met and the operational cost of the FermiCloud is minimized. Our earlier research shows that VM launching overhead has large variations. If such variations are not taken into consideration when making resource allocation decisions, it may lead to poor performance and resource waste. In this paper, we show how we may use an VM launching overhead reference model to minimize VM launching overhead. In particular, we first present a training algorithm that automatically tunes a given refer- ence model to accurately reflect FermiCloud environment. Based on the tuned reference model for virtual machine launching overhead, we develop an overhead-aware-best-fit resource allocation algorithm that decides where and when to allocate resources so that the average virtual machine launching overhead is minimized. The experimental results indicate that the developed overhead-aware-best-fit resource allocation algorithm can significantly improved the VM launching time when large number of VMs are simultaneously launched.

  20. Chosen Ciphertext Security with Optimal Ciphertext Overhead

    Science.gov (United States)

    Abe, Masayuki; Kiltz, Eike; Okamoto, Tatsuaki

    Every public-key encryption scheme has to incorporate a certain amount of randomness into its ciphertexts to provide semantic security against chosen ciphertext attacks (IND-CCA). The difference between the length of a ciphertext and the embedded message is called the ciphertext overhead. While a generic brute-force adversary running in 2t steps gives a theoretical lower bound of t bits on the ciphertext overhead for IND-CPA security, the best known IND-CCA secure schemes demand roughly 2t bits even in the random oracle model. Is the t-bit gap essential for achieving IND-CCA security? We close the gap by proposing an IND-CCA secure scheme whose ciphertext overhead matches the generic lower bound up to a small constant. Our scheme uses a variation of a four-round Feistel network in the random oracle model and hence belongs to the family of OAEP-based schemes. Maybe of independent interest is a new efficient method to encrypt long messages exceeding the length of the permutation while retaining the minimal overhead.

  1. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  2. 30 CFR 56.16014 - Operator-carrying overhead cranes.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Operator-carrying overhead cranes. 56.16014 Section 56.16014 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage and Handling § 56.16014 Operator-carrying overhead cranes. Operator-carrying overhead cranes shall...

  3. 30 CFR 57.16014 - Operator-carrying overhead cranes.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Operator-carrying overhead cranes. 57.16014 Section 57.16014 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage and Handling § 57.16014 Operator-carrying overhead cranes. Operator-carrying overhead cranes shall...

  4. Human Factors Engineering Guidelines for Overhead Cranes

    Science.gov (United States)

    Chandler, Faith; Delgado, H. (Technical Monitor)

    2001-01-01

    This guideline provides standards for overhead crane cabs that can be applied to the design and modification of crane cabs to reduce the potential for human error due to design. This guideline serves as an aid during the development of a specification for purchases of cranes or for an engineering support request for crane design modification. It aids human factors engineers in evaluating existing cranes during accident investigations or safety reviews.

  5. Operational overhead of moving to higher energies

    CERN Document Server

    Lamont, M

    2011-01-01

    The operational overheads of moving above 3.5 TeV are examined. The costs of performing such a move at the start, or during, the 2011 run are evaluated. The impact of operation with beams above 3.5 TeV on machine protection systems is briefly reviewed, and any potential limitations are enumerated. Finally the possible benefits of increasing the beam energy on the luminosity are discussed.

  6. Design Of Overhead Roadway At Road Intersection

    Directory of Open Access Journals (Sweden)

    Raji

    2017-08-01

    Full Text Available This project deals with the Design of overhead-roadway located at CHALLENGE junction which is a T-junction. Analysis of the existing conditions was carried out to proffers solution to the cause of the problems occurring due to the vehicle competing for space at this intersection. Before carrying out the analysis a traffic surveys at peak hours for morning 0730 to 0830 am and afternoon 0300 to 0400 pm were conducted using 15 minutes interval. From the analysis it was found out that the peak hour factor and flow rate was 0.88 and 1656pcphpl respectively corresponding to LOS E. This implies that the capacity of the existing road is no longer able to accommodate the traffic flow hence overhead roadway was introduced to improve the efficiency of the intersection. The overhead-roadway is of 140 m length with 7 spans 20 m per span. It consists of a deck slab longitudinal girders cross girders deck beam pier foundation and retailing wall. All structural parts for this Flyover were designed using Staad professional software package and Manual method.

  7. Fort Peck-Wolf Point transmission line project, Montana

    International Nuclear Information System (INIS)

    1992-01-01

    The primary objective of the project is to replace the existing 36-mile Fort Peck-Wolf Point transmission line which has reached the end of its useful service life. Presently, the overall condition of this existing section of the 47-year-old line is poor. Frequent repairs have been required because of the absence of overhead ground wires. The continued maintenance of the line will become more expensive and customer interruptions will persist because of the damage due to lightning. The expense of replacing shell rotted poles, and the concern for the safety of the maintenance personnel because of hazards caused by severe shell rot are also of primary importance. The operational and maintenance problems coupled with power system simulation studies, demonstrate the need for improvements to the Wolf Point area to serve area loads. Western's Wolf Point Substation is an important point of interconnection for the power output from the Fort Peck Dam to area loads as far away as Williston, North Dakota. The proposed transmission line replacement would assure that there will continue to be reliable transmission capacity available to serve area electrical loads, as well as provide a reliable second high-voltage transmission path from the Fort Peck generation to back-up a loss of the Fort Peck-Wolf Point 115-kV Line No. 1

  8. Low overhead and nonlinear-tolerant adaptive zero-guard-interval CO-OFDM.

    Science.gov (United States)

    Wang, Wei; Zhuge, Qunbi; Gao, Yuliang; Qiu, Meng; Morsy-Osman, Mohamed; Chagnon, Mathieu; Xu, Xian; Plant, David V

    2014-07-28

    We propose an adaptive channel estimation (CE) method for zero-guard-interval (ZGI) coherent optical (CO)-OFDM systems, and demonstrate its performance in a single channel 28 Gbaud polarization-division multiplexed ZGI CO-OFDM experiment with only 1% OFDM processing overhead. We systematically investigate its robustness against various transmission impairments including residual chromatic dispersion, polarization-mode dispersion, state of polarization rotation, sampling frequency offset and fiber nonlinearity. Both experimental and numerical results show that the adaptive CE-aided ZGI CO-OFDM is highly robust against these transmission impairments in fiber optical transmission systems.

  9. 735 kV circuit breakers for ehv

    Energy Technology Data Exchange (ETDEWEB)

    1966-01-01

    French manufacturers have been studying the design of high and extra high voltage circuit breakers for several years. The two techniques they used were the low volume oil and the air pressure technique. These have permitted the development of a type gear capable of solving problems all over the world as they arose following the development of electrical energy transmission at extra high voltage as well as high short circuit power. Today, the air pressure solution is used in new constructions such as the 735 kV transmission network in Canada.

  10. Partial discharge location technique for covered-conductor overhead distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Isa, M.

    2013-02-01

    In Finland, covered-conductor (CC) overhead lines are commonly used in medium voltage (MV) networks because the loads are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees which produce partial discharges (PDs) in CC lines. This thesis presents a technique to locate the PD source on CC overhead distribution line networks. The algorithm is developed and tested using a simulated study and experimental measurements. The Electromagnetic Transient Program-Alternative Transient Program (EMTP-ATP) is used to simulate and analyze a three-phase PD monitoring system, while MATLAB is used for post-processing of the high frequency signals which were measured. A Rogowski coil is used as the measuring sensor. A multi-end correlation-based technique for PD location is implemented using the theory of maximum correlation factor in order to find the time difference of arrival (TDOA) between signal arrivals at three synchronized measuring points. The three stages of signal analysis used are: (1) denoising by applying discrete wavelet transform (DWT); (2) extracting the PD features using the absolute or windowed standard deviation (STD) and; (3) locating the PD point. The advantage of this technique is the ability to locate the PD source without the need to know the first arrival time and the propagation velocity of the signals. In addition, the faulty section of the CC line between three measuring points can also be identified based on the degrees of correlation. An experimental analysis is performed to evaluate the PD measurement system performance for PD location on CC overhead lines. The measuring set-up is arranged in a high voltage (HV) laboratory. A multi-end measuring method is chosen as a technique to locate the PD source point on the line. A power transformer 110/20 kV was used to energize the AC voltage up to 11.5 kV/phase (20 kV system). The tests were designed to cover different conditions such as offline and online

  11. Fiscal 1999 research result report on energy and environment technology demonstration research support project (International joint demonstration research project). Improvement of long-distant power transmission efficiency and reliability, and its environmental impact assessment; 1999 nendo chokyori soden hoshiki ni kansuru soden koritsu to soden shinraido no kojo oyobi kankyo eno eikyo hyoka seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Japan-Russia international joint research was made on overhead ultrahigh-voltage DC power transmission lines for transmission loss reduction and reliability improvement, and an optimum international power supply cable system, considering energy saving and environment conservation. Using the European-Russian DC power transmission line of {+-}500kV and 4GW as a model, comparison was made between a model using Russian round strands and glass insulators and a model using Japanese low-loss wires and insulators. As for improvement of the reliability in cold districts, Russian design techniques for tower structure and ice loading were reasonable to counteract galloping oscillation and ice load. In evaluation and selection of optimum underground and marine cables, study was made on cable specifications using the Turkey-Russia power transmission route as a model. The environmental assessment result of these cables showed that XLPE cable under development is optimum. (NEDO)

  12. Kv1 channels and neural processing in vestibular calyx afferents

    Directory of Open Access Journals (Sweden)

    Frances L Meredith

    2015-06-01

    Full Text Available Potassium-selective ion channels are important for accurate transmission of signals from auditory and vestibular sensory end organs to their targets in the central nervous system. During different gravity conditions, astronauts experience altered input signals from the peripheral vestibular system resulting in sensorimotor dysfunction. Adaptation to altered sensory input occurs, but it is not explicitly known whether this involves synaptic modifications within the vestibular epithelia. Future investigations of such potential plasticity require a better understanding of the electrophysiological mechanisms underlying the known heterogeneity of afferent discharge under normal conditions. This study advances this understanding by examining the role of the Kv1 potassium channel family in mediating action potentials in specialized vestibular afferent calyx endings in the gerbil crista and utricle. Pharmacological agents selective for different sub-types of Kv1 channels were tested on membrane responses in whole cell recordings in the crista. Kv1 channels sensitive to α-dendrotoxin and dendrotoxin-K were found to prevail in the central regions, whereas K+ channels sensitive to margatoxin, which blocks Kv1.3 and 1.6 channels, were more prominent in peripheral regions. Margatoxin-sensitive currents showed voltage-dependent inactivation. Dendrotoxin-sensitive currents showed no inactivation and dampened excitability in calyces in central neuroepithelial regions. The differential distribution of Kv1 potassium channels in vestibular afferents supports their importance in accurately relaying gravitational and head movement signals through specialized lines to the central nervous system. Pharmacological modulation of specific groups of K+ channels could help alleviate vestibular dysfunction on earth and in space.

  13. Kv1 channels and neural processing in vestibular calyx afferents.

    Science.gov (United States)

    Meredith, Frances L; Kirk, Matthew E; Rennie, Katherine J

    2015-01-01

    Potassium-selective ion channels are important for accurate transmission of signals from auditory and vestibular sensory end organs to their targets in the central nervous system. During different gravity conditions, astronauts experience altered input signals from the peripheral vestibular system resulting in sensorimotor dysfunction. Adaptation to altered sensory input occurs, but it is not explicitly known whether this involves synaptic modifications within the vestibular epithelia. Future investigations of such potential plasticity require a better understanding of the electrophysiological mechanisms underlying the known heterogeneity of afferent discharge under normal conditions. This study advances this understanding by examining the role of the Kv1 potassium channel family in mediating action potentials in specialized vestibular afferent calyx endings in the gerbil crista and utricle. Pharmacological agents selective for different sub-types of Kv1 channels were tested on membrane responses in whole cell recordings in the crista. Kv1 channels sensitive to α-dendrotoxin and dendrotoxin-K were found to prevail in the central regions, whereas K(+) channels sensitive to margatoxin, which blocks Kv1.3 and 1.6 channels, were more prominent in peripheral regions. Margatoxin-sensitive currents showed voltage-dependent inactivation. Dendrotoxin-sensitive currents showed no inactivation and dampened excitability in calyces in central neuroepithelial regions. The differential distribution of Kv1 potassium channels in vestibular afferents supports their importance in accurately relaying gravitational and head movement signals through specialized lines to the central nervous system. Pharmacological modulation of specific groups of K(+) channels could help alleviate vestibular dysfunction on earth and in space.

  14. Scale model test on a novel 400 kV double-circuit composite pylon

    DEFF Research Database (Denmark)

    Wang, Qian; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    This paper investigates lightning shielding performance of a novel 400 kV double-circuit composite pylon, with the method of scale model test. Lightning strikes to overhead lines were simulated by long-gap discharges between a high voltage electrode with an impulse voltage and equivalent conductors...... around the pylon is discussed. Combined test results and striking distance equation in electro-geometric model, the approximate maximum lightning current that can lead to shielding failure is calculated. Test results verify that the unusual negative shielding angle of - 60° in the composite pylon meets...... requirement and the shielding wires provide acceptable protection from lightning strikes....

  15. Hvor fosser kvælstoffet hen?

    DEFF Research Database (Denmark)

    Larsen, Torben

    Der har i Ingeniøren inden i et par måneder kunne læses adskillelige ivrige indlæg om de danske fjordes evne til at fjerne kvælstof. Kvælstof fosser ud af fjordene? lød en af de første overskrifter. Få uger efter blev det stik modsatte synspunkt fremført under overskriften Fjordene holder på kvæl...

  16. Mitochondrial ultrastructure and glucose signaling pathways attributed to the Kv1.3 ion channel

    Directory of Open Access Journals (Sweden)

    Christopher P. Kovach

    2016-05-01

    Full Text Available Gene-targeted deletion of the potassium channel Kv1.3 (Kv1.3-/- results in ‘Super-smeller’ mice with a sensory phenotype that includes an increased olfactory ability linked to changes in olfactory circuitry, increased abundance of olfactory cilia, and increased expression of odorant receptors and the G-protein, Golf. Kv1.3-/- mice also have a metabolic phenotype including lower body weight and decreased adiposity, increased total energy expenditure (TEE, increased locomotor activity, and resistance to both diet- and genetic-induced obesity. We explored two cellular aspects to elucidate the mechanism by which loss of Kv1.3 channel in the olfactory bulb (OB may enhance glucose utilization and metabolic rate. First, using in situ hybridization we find that Kv1.3 and the insulin-dependent glucose transporter type 4 (GLUT4 is co-localized to the mitral cell layer of the OB. Disruption of Kv1.3 conduction via construction of a pore mutation (W386F Kv1.3 was sufficient to independently translocate GLUT4 to the plasma membrane in HEK 293 cells. Because olfactory sensory perception and the maintenance of action potential firing frequency by mitral cells of the OB is highly energy demanding and Kv1.3 is also expressed in mitochondria, we next explored the structure of this organelle in mitral cells. We challenged wildtype (WT and Kv1.3-/- male mice with a moderately high-fat diet (MHF, 31.8 % kcal fat for 4 months and then examined OB ultrastructure using transmission microscopy. In WT mice, mitochondria were significantly enlarged following diet-induced obesity (DIO and there were fewer mitochondria, likely due to mitophagy. Interestingly, mitochondria were significantly smaller in Kv1.3-/- mice compared with that of WT mice. Similar to their metabolic resistance to DIO, the Kv1.3-/- mice had unchanged mitochondria in terms of cross sectional area and abundance following a challenge with modified diet. We are very interested to understand how

  17. The electrically silent Kv6.4 subunit confers hyperpolarized gating charge movement in Kv2.1/Kv6.4 heterotetrameric channels.

    Directory of Open Access Journals (Sweden)

    Elke Bocksteins

    Full Text Available The voltage-gated K(+ (Kv channel subunit Kv6.4 does not form functional homotetrameric channels but co-assembles with Kv2.1 to form functional Kv2.1/Kv6.4 heterotetrameric channels. Compared to Kv2.1 homotetramers, Kv6.4 exerts a ~40 mV hyperpolarizing shift in the voltage-dependence of Kv2.1/Kv6.4 channel inactivation, without a significant effect on activation gating. However, the underlying mechanism of this Kv6.4-induced modulation of Kv2.1 channel inactivation, and whether the Kv6.4 subunit participates in the voltage-dependent gating of heterotetrameric channels is not well understood. Here we report distinct gating charge movement of Kv2.1/Kv6.4 heterotetrameric channels, compared to Kv2.1 homotetramers, as revealed by gating current recordings from mammalian cells expressing these channels. The gating charge movement of Kv2.1/Kv6.4 heterotetrameric channels displayed an extra component around the physiological K(+ equilibrium potential, characterized by a second sigmoidal relationship of the voltage-dependence of gating charge movement. This distinct gating charge displacement reflects movement of the Kv6.4 voltage-sensing domain and has a voltage-dependency that matches the hyperpolarizing shift in Kv2.1/Kv6.4 channel inactivation. These results provide a mechanistic basis for the modulation of Kv2.1 channel inactivation gating kinetics by silent Kv6.4 subunits.

  18. Overhead mining railway, particularly for underground use

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, L

    1976-05-20

    Overhead mining railways are usually equipped with a friction wheel drive in underground use. This drive has the advantage over a gear drive that it is more robust and therefore more economic. However, it produces unsatisfactory running for difficult sections with steep gradients up or down or places where deposits of grease and dirt are inevitable. It is proposed to change over to a gear drive at such sections. The high degree of wear, which is characteristic of this type of drive, can be reduced if the drive is only used in difficult sections. It is proposed that the gear drive should be automatically switched on and off by means of stops or contacts on the rails.

  19. ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV

    Directory of Open Access Journals (Sweden)

    Yu. N. Shumilov

    2018-02-01

    Full Text Available Introduction. In Ukraine high voltage overhead distribution lines (OL of class 6 and 10 kV are the most extended. Their total length exceeds 280,000 km. More than 95% of the lines are made on line supports from reinforced concrete racks. On all poles of the overhead line, pin insulators are installed. According to the data of operation experience, up to 60-70% of single-phase earth (SPE faults due to «insulation» occurs on VL supports due to damage to line pin insulators, mainly during the thunderstorm period. Problem. Insufficient reliability of pin insulators leads to interruptions in power supply, accidents on the line, accidents in the area of reinforced concrete poles, where in the case of insulator damages, a long process of SPE occurs. Goal. The purpose of the work is to select the design and develop requirements for new linear insulators of 10-20 kV overhead lines that provide high resistance to lightning overvoltages with direct and inductive effects of lightning. Methodology. The research methodology consists in analyzing operational experience, calculating insulator parameters and laboratory tests. Results. Using statistical data on lightning parameters and data on mechanical loads on insulators, the main dimensions of line post insulators have been determined that will ensure their reliable operation under conditions of intense thunderstorm activity and extreme ice and wind loads. Conclusions. The main technical requirements for line post insulators for 10-20 kV distribution lines were formulated. On the 10 kV OL located in areas with increased thunderstorm activity it is recommended to use line post insulators instead of pin-type ones. On the OL-20 kV it is recommended to use only line post insulators. The use of high-lightning-resistant line post insulators on OL-10-20 kV will significantly increase the electrical safety and reliability of power supply to consumers. Increased by 2-3 times the cost of line post insulators in

  20. Design and testing of reactors for 735 kV

    Energy Technology Data Exchange (ETDEWEB)

    Erb, W; Kraaij, D J

    1965-11-01

    The design and testing of five large, single phase shunt reactors rated either 110 or 55 MVAR, supplied for the 735 kV system of the Quebec Hydro Electric Commission which came into operation in the autumn of 1965 are described. As these reactors are permanently connected to the transmission lines, their losses must be considered as being continuously present and must be determined exactly. In addition to the use of a new bridge method, the losses were also measured calorimetrically for the purpose of comparison, the agreement between the two tests being remarkably good. The impulse tests with full wave and chopped wave are subsequently described.

  1. Improvements in the computation of balances and localization of commercial losses of electric energy in 0.38-kV networks

    International Nuclear Information System (INIS)

    Vorotnitskii, V. Z.; Zaslonov, S. V.; Lysyuk, S. S.

    2006-01-01

    An example of four 0.38-kV overhead distribution lines fed from a 10/0.4-kV transformer substation of the Grodno Electrical Networks (Belarus') and supplying electricity to a cottage area is used for analyzing energy balances and commercial losses in the networks. It is shown that the reliability of such analysis can be ensured by the use of modern software and electronic energy meters recording a retrospective of half-hourly intervals of active and reactive electric energy

  2. Asbestos fiber release from the brake pads of overhead industrial cranes.

    Science.gov (United States)

    Spencer, J W; Plisko, M J; Balzer, J L

    1999-06-01

    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibers were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranged from cranes.

  3. Throughput, Energy and Overhead of Multicast Device-to-Device Communications with Network Coded Cooperation

    DEFF Research Database (Denmark)

    Hernandez, Nestor; Heide, Janus; Roetter, Daniel Enrique Lucani

    2017-01-01

    , this assumes that the throughput gains and energy savings in multicasting are much larger between devices than the base station to the receivers. However, current mobile networks suffer from many different issues varying the performance in data rates, which calls into question these assumptions. Therefore......, a first objective of this work is to assess the operating regions where employing cooperation results in higher throughput and/or energy savings. We consider multicast scenarios with network coded mechanisms employing Random Linear Network Coding (RLNC). However, although RLNC is good for low amount...... of transmissions in multicast, it has an inherent overhead from extreme high or low field related caveats. Thus, as a second objective, we review and propose the application of new network codes that posses low overhead for multicasting, by having a short representation and low dependence probability. We provide...

  4. Precision overhead irrigation is suitable for several Central Valley crops

    Directory of Open Access Journals (Sweden)

    Jeffrey P. Mitchell

    2016-04-01

    Full Text Available Overhead systems are the dominant irrigation technology in many parts of the world, but they are not widely used in California even though they have higher water application efficiency than furrow irrigation systems and lower labor requirements than drip systems. With water and labor perennial concerns in California, the suitability of overhead systems merits consideration. From 2008 through 2013, in studies near Five Points, California, we evaluated overhead irrigation for wheat, corn, cotton, tomato, onion and broccoli as an alternative to furrow and drip irrigation. With the exception of tomato, equal or increased yields were achieved with overhead irrigation. Many variables are involved in the choice of an irrigation system, but our results suggest that, with more research to support best management practices, overhead irrigation may be useful to a wider set of California farmers than currently use it.

  5. Actual practical considerations about overhead line engineering. Planning of overhead lines is booming; Aktuelle praktische Betrachtung der Freileitungstechnik. Freileitungsplanung boomt

    Energy Technology Data Exchange (ETDEWEB)

    Bueckner, W.F.

    2007-04-30

    The power breakdowns we encountered in March 2006 due to extreme weather conditions and in November 2006 due to overload of overhead lines made overhead line techniques more interesting. After pausing for decades, technical development and investments for overhead lines in Germany become necessary again, meaning reconstructions and new constructions worth several millions of investment. An additional reason for this is given by the Federal Government's request for the construction of new power plants and overhead lines as well as by the energy plan of the EU-Commission. The power supplier have begun planning already. These plans require new and economical overhead lines. Proposals and practical examples are shown in the following article.

  6. Effects of electromagnetic field of 33 and 275 kV influences on ...

    African Journals Online (AJOL)

    The effects of electromagnetic fields (EMF) from 33 and 275 kV high voltage transmission line on biochemical and antioxidant system changes in mustard leaf (Brassica chinensis) were investigated under field condition. Mustard leaves were exposed to EMF from power lines at distances of 0, 3, 6, 9, 10, 12, 15, 18, 20, 21, ...

  7. Axon initial segment Kv1 channels control axonal action potential waveform and synaptic efficacy

    NARCIS (Netherlands)

    Kole, Maarten H. P.; Letzkus, Johannes J.; Stuart, Greg J.

    2007-01-01

    Action potentials are binary signals that transmit information via their rate and temporal pattern. In this context, the axon is thought of as a transmission line, devoid of a role in neuronal computation. Here, we show a highly localized role of axonal Kv1 potassium channels in shaping the action

  8. Arc Flash Personal Protective Equipment (PPE) Requirements for High-Voltage Overhead Line Work at 69 KV (Nominal) or Less

    National Research Council Canada - National Science Library

    Hammond, Daryl

    2006-01-01

    ... after work is complete, and in those rare occasions when the authority in Air Force Instruction (AFI) 32-1064, Electrical Safe Practices, authorizes work on energized electrical equipment or lines.

  9. Corona performance of a compact 230-kV line

    International Nuclear Information System (INIS)

    Chartier, V.L.; Blair, D.E.

    1994-01-01

    Permitting requirements and the acquisition of new rights-of-way for transmission facilities has in recent years become increasingly difficult for most utilities, including Puget Sound Power and Light Company. In order to maintain a high degree of reliability of service while being responsive to public concerns regarding the siting of high voltage (HV) transmission facilities, Puget Power has found it necessary to more heavily rely upon the use of compact lines in franchise corridors. Compaction does, however, precipitant increased levels of audible noise (AN) and radio and TV interference (RI and TVI) due to corona on the conductors and insulator assemblies. Puget Power relies upon the Bonneville Power Administration (BPA) Corona and Field Effects computer program to calculate AN and RI for new lines. Since there was some question of the program's ability to accurately represent quiet 230-kV compact designs, a joint project was undertaken with BPA to verify the program's algorithms. Long-term measurements made on an operating Puget Power 230-kV compact line confirmed the accuracy of BPA's AN model; however, the RI measurements were much lower than predicted by the BPA computer and other programs. This paper also describes how the BPA computer program can be used to calculate the voltage needed to expose insulator assemblies to the correct electric field in single test setups in HV laboratories

  10. Decreased expression of Kv7 channels in Hirchsprung's disease.

    Science.gov (United States)

    O'Donnell, Anne-Marie; Coyle, David; Puri, Prem

    2017-07-01

    Voltage-dependent K + channels (Kv channels) participate in electrical rhythmicity and smooth muscle responses and are regulated by excitatory and inhibitory neurotransmitters. Kv channels also participate in the interstitial cell of Cajal (ICC) and smooth muscle cell (SMC) responses to neural inputs. The Kv family consists of 12 subfamilies, Kv1-Kv12, with five members of the Kv7 family identified to date: Kv7.1-Kv7.5. A recent study identified the potassium channel Kv7.5 as having a role in the excitability of ICC-IM in the mouse colon. We therefore designed this study to test the hypothesis that Kv7 channels are present in the normal human colon and are reduced in Hirschprung's disease (HSCR). HSCR tissue specimens were collected at the time of pull-through surgery (n=10), while normal control tissue specimens were obtained at the time of colostomy closure in patients with imperforate anus (n=10). Kv7.3-Kv7.5 immunohistochemistry was performed and visualized using confocal microscopy to assess their distribution. Western blot analysis was undertaken to determine Kv7.3-Kv7.5 protein quantification. Kv7.3 and Kv7.4-immunoreactivity was co-localized with neuron and ICC markers, while Kv7.5 was found to be expressed on both ICCs and SMCs. Western blot analysis revealed similar levels of Kv7.3 and Kv7.5 expression in the normal colon and HSCR colon, while Kv7.4 proteins were found to be markedly decreased in ganglionic specimens and decreased further in aganglionic specimens. A deficiency of Kv7.4 channels in the ganglionic and aganglionic bowel may place a role in colonic dysmotility in HSCR. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. VT VEC Primary Overhead and Underground Distribution Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Vermont Electric Cooperative, Inc. (VEC) Primary Overhead and Underground Distribution Lines. VEC’s Distribution lines were drawn from pole to...

  12. Study on earthquake responses of overhead traveling cranes

    International Nuclear Information System (INIS)

    Komori, A.; Fukuda, T.; Veki, T.; Kirata, M.; Hoshii, T.; Kashiwazaki, A.

    1989-01-01

    In nuclear power plants, large-size overhead traveling cranes, such as reactor building crane and turbine building crane, are installed. These overhead cranes are used for transporting heavy loads on the operation floor, and call for safety and reliability even during strong earthquake as well as under the normal operational conditions. The seismic behaviors of overhead traveling cranes, which move on the rails, may be different from those of other structures that are anchored to the building: in the case of cranes, traveling wheels and rails can slip relative to each other when the horizontal seismic force reaches the level of frictional force. In Japan, therefore, a practical guide to the seismic design that considers the sliding has been proposed. However, detailed experimental study on sliding between wheels and rails has not been carried out. In this study, the seismic behaviors of traveling overhead cranes accompanied by sliding between wheels and rails in the traveling direction are examined

  13. Problems due to icing of overhead lines - Part II

    International Nuclear Information System (INIS)

    Havard, D.G.; Pon, C.J.; Krishnasamy, S.G.

    1985-01-01

    A companion paper describes uncertainties in overhead line design due to the variability of ice and wind loads. This paper reviews two other effects due to icing; conductor galloping and torsional instability, which require further study. (author)

  14. Use of Overhead Transparencies in Collaborative Business Writing.

    Science.gov (United States)

    Barker, Randolph T.; And Others

    1991-01-01

    Asserts that small group collaborative writing exercises that produce overhead transparencies for large class critique can be an effective method for teaching letter and memorandum construction. Offers a five-step process for encouraging individual and collaborative writing skills. (PRA)

  15. Collecting and using weather data for the design of overhead lines according to IEC 60826

    International Nuclear Information System (INIS)

    Rolfseng, L.; Fikke, S.; Ghannoum, E.

    2005-01-01

    Ice and wind loads on conductors and earth wires are the most important environmental factors for the mechanical design of overhead lines. This paper addressed the economic importance of long-term recording and measuring of weather data and provided details of their use according to a recent International Electrochemical Commission technical report (60826). The procedures used to calculate design weather loads by applying the Gumbal cumulative distribution function were outlined using data collected from Studnice in the Czech Republic, where ice loads have been measured since 1940. Based on the calculations, it was suggested that predicting ice loads based on a reduced number of years may lead to either under or over designing overhead lines. An example of ice load measurements and records showed that the standard deviation of maximum annual ice loads is large. Ice and wind load data from previous technical reports were presented. It was noted that the number of years with observations, the average value and the standard deviation are the necessary parameters for making the statistical analyses of design wind and ice loads. Information on cost of overhead lines in Norway was provided, as well as details of ice load recommendations currently used. It was estimated that the total price of the uncertainty in the design ice loads for the total electric overhead line network in Norway was $30 million, representing 10 per cent of the annual replacement value of the grid. It was concluded that long-term data acquisition of ice loads could reduce investment costs when design ice loads are too high, and also alleviate damage to transmission system and loss of supply due to ice storms when the design ice value is too low. 3 refs., 4 tabs., 4 figs

  16. Functional analysis of Kv1.2 and paddle chimera Kv channels in planar lipid bilayers

    Science.gov (United States)

    Tao, Xiao; MacKinnon, Roderick

    2010-01-01

    Summary Voltage-dependent K+ channels play key roles in shaping electrical signaling in both excitable as well as non-excitable cells. These channels open and close in response to the voltage changes across the cell membrane. Many studies have been carried out in order to understand the voltage sensing mechanism. Our laboratory recently determined the atomic structures of a mammalian voltage-dependent K+ channel Kv1.2 and a mutant of Kv1.2 named the ‘paddle-chimera’ channel, in which the voltage sensor paddle was transferred from Kv2.1 to Kv1.2. These two structures provide atomic descriptions of voltage-dependent channels with unprecedented clarity. Until now the functional integrity of these two channels biosynthesized in yeast cells have not been assessed. Here we report the electrophysiological and pharmacological properties of Kv1.2 and the paddle chimera channels in planar lipid bilayers. We demonstrate that Pichia yeast produce ‘normally functioning’ mammalian voltage-dependent K+ channels with qualitatively similar features to the Shaker K+ channel in the absence of the N-terminal inactivation gate, and that the paddle chimera mutant channel functions as well as Kv1.2. We find, however, that in several respects the Kv1.2 channel exhibits functional properties that are distinct from Kv1.2 channels reported in the literature. PMID:18638484

  17. Computer-based mechanical design of overhead lines

    Science.gov (United States)

    Rusinaru, D.; Bratu, C.; Dinu, R. C.; Manescu, L. G.

    2016-02-01

    Beside the performance, the safety level according to the actual standards is a compulsory condition for distribution grids’ operation. Some of the measures leading to improvement of the overhead lines reliability ask for installations’ modernization. The constraints imposed to the new lines components refer to the technical aspects as thermal stress or voltage drop, and look for economic efficiency, too. The mechanical sizing of the overhead lines is after all an optimization problem. More precisely, the task in designing of the overhead line profile is to size poles, cross-arms and stays and locate poles along a line route so that the total costs of the line's structure to be minimized and the technical and safety constraints to be fulfilled.The authors present in this paper an application for the Computer-Based Mechanical Design of the Overhead Lines and the features of the corresponding Visual Basic program, adjusted to the distribution lines. The constraints of the optimization problem are adjusted to the existing weather and loading conditions of Romania. The outputs of the software application for mechanical design of overhead lines are: the list of components chosen for the line: poles, cross-arms, stays; the list of conductor tension and forces for each pole, cross-arm and stay for different weather conditions; the line profile drawings.The main features of the mechanical overhead lines design software are interactivity, local optimization function and high-level user-interface

  18. 735 kV air-blast circuit breakers for Hydro Quebec

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, I

    1966-01-01

    In 1962 the Quebec Hydro-Electric Commission started the development of aproject for utilizing water power in Manicouagan and Outardes, two rivers some 350 miles northeast of the city of Montreal on the left bank of the St. Lawrence estuary. The project involved the transmission of power at 735 kV ac from Manicouagan and Outardes to the heavy and growing load centers of Quebec and Montreal. The total amount of energy to be transmitted in the final stage is about 6,000 MW. The project involved the need of considerable quantities of apparatus for 735 kV, such as transformers, reactors, lightning arrestors, circuit-breakers, and disconnectors. Since the supply of the major part of the 735 kV circuit-breakers, altogether 14 three-pole units, was awarded to ASEA in Sweden, a short presentation of these airblast circuit-breakers is presented.

  19. Transmission delays in hardware clock synchronization

    Science.gov (United States)

    Shin, Kang G.; Ramanathan, P.

    1988-01-01

    Various methods, both with software and hardware, have been proposed to synchronize a set of physical clocks in a system. Software methods are very flexible and economical but suffer an excessive time overhead, whereas hardware methods require no time overhead but are unable to handle transmission delays in clock signals. The effects of nonzero transmission delays in synchronization have been studied extensively in the communication area in the absence of malicious or Byzantine faults. The authors show that it is easy to incorporate the ideas from the communication area into the existing hardware clock synchronization algorithms to take into account the presence of both malicious faults and nonzero transmission delays.

  20. A Reference Model for Virtual Machine Launching Overhead

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao; Ren, Shangping; Garzoglio, Gabriele; Timm, Steven; Bernabeu, Gerard; Chadwick, Keith; Noh, Seo-Young

    2016-07-01

    Cloud bursting is one of the key research topics in the cloud computing communities. A well designed cloud bursting module enables private clouds to automatically launch virtual machines (VMs) to public clouds when more resources are needed. One of the main challenges in developing a cloud bursting module is to decide when and where to launch a VM so that all resources are most effectively and efficiently utilized and the system performance is optimized. However, based on system operational data obtained from FermiCloud, a private cloud developed by the Fermi National Accelerator Laboratory for scientific workflows, the VM launching overhead is not a constant. It varies with physical resource utilization, such as CPU and I/O device utilizations, at the time when a VM is launched. Hence, to make judicious decisions as to when and where a VM should be launched, a VM launching overhead reference model is needed. In this paper, we first develop a VM launching overhead reference model based on operational data we have obtained on FermiCloud. Second, we apply the developed reference model on FermiCloud and compare calculated VM launching overhead values based on the model with measured overhead values on FermiCloud. Our empirical results on FermiCloud indicate that the developed reference model is accurate. We believe, with the guidance of the developed reference model, efficient resource allocation algorithms can be developed for cloud bursting process to minimize the operational cost and resource waste.

  1. Systems for protection and automation of distribution electric networks 22 kv

    International Nuclear Information System (INIS)

    Horak, M.

    2012-01-01

    This article deals with the new concept of fault location in overhead and cable 22 kV distribution systems, which are operated by ZSE Distribucia, a.s.. In the past the localisation of faults was a demanding and lengthy procedure, because the electric protection indicated only the affected output feeder. The exact fault point was then localised by manipulation in the field and by test switching in the power line where the fault took place. The current development of electric facilities and sharp fall in prices give use the possibility to broadly apply the simple digital metering devices equipped with the electric protection function. Once these devices are positioned densely along the individual power lines of the network, it is possible to localise the failure position quite exactly and electricity supply can be quickly restored. (Authors)

  2. Accounting of allocation of production enterprises’ overhead costs

    Directory of Open Access Journals (Sweden)

    О.V. Ivaniuta

    2016-12-01

    Full Text Available Taking into account the complexity of engineering technological cycles, the use of traditional approaches to the allocation of overhead costs at the researching enterprises is inexpedient and inefficient. The authors find out that to solve this problem it is not enough to choose only one base of allocation because the formed prime cost with such an approach will not meet the reality. That is why it is suggested to use a multilevel allocation of overhead costs. The proposed approach involves the allocation of overhead costs at the following levels: fixed and variable, with shops of main and auxiliary production, calculation stations, some orders. Each level involves the selection of individual allocation bases that are grouped on economic, technological and integrated ones.

  3. Communication Characteristics of Faulted Overhead High Voltage Power Lines at Low Radio Frequencies

    Directory of Open Access Journals (Sweden)

    Nermin Suljanović

    2017-11-01

    Full Text Available This paper derives a model of high-voltage overhead power line under fault conditions at low radio frequencies. The derived model is essential for design of communication systems to reliably transfer information over high voltage power lines. In addition, the model can also benefit advanced systems for power-line fault detection and classification exploiting the phenomenon of changed conditions on faulted power line, resulting in change of low radio frequency signal propagation. The methodology used in the paper is based on the multiconductor system analysis and propagation of electromagnetic waves over the power lines. The model for the high voltage power line under normal operation is validated using actual measurements obtained on 400 kV power line. The proposed model of faulted power lines extends the validated power-line model under normal operation. Simulation results are provided for typical power line faults and typical fault locations. Results clearly indicate sensitivity of power-line frequency response on different fault types.

  4. Seismic behavior with sliding of overhead travelling crane

    International Nuclear Information System (INIS)

    Komori, Akio; Ueki, Takashi; Hirata, Masami; Hoshii, Tsutomu; Kashiwazaki, Akihiro.

    1989-01-01

    In this study, the seismic behavior of an overhead travelling crane with the sliding between travelling wheels and rails is examined. First, the dynamic characteristic test of the actual crane installed in a reactor building and the sliding test of the rigid-element model to observe the basic sliding characteristic were performed. Next, to examine the dynamic response with sliding, shaking tests using the scaled model of an actual crane were conducted. From these results, useful design information about seismic behavior of an overhead travelling crane was obtained. It was also observed that numerical predictions considering sliding behavior have good agreement with the experimental results and are applicable to seismic design. (author)

  5. 250 kV aim for hvdc valves

    Energy Technology Data Exchange (ETDEWEB)

    1966-06-01

    Development now being carried out by ASEA is aimed at increasing the normal operating voltage for a mercury arc valve to 250 kV dc. The maximum direct voltage per valve group, with one valve in each arm of the bridge, is 125 kV for equipment already in operation in New Zealand, Japan, and Konti Scan. Valves for 130 kV and 133 kV operation are under construction for the Vancouver and the Pacific Intertie 1 links.

  6. Functional properties of human neuronal Kv11 channels

    DEFF Research Database (Denmark)

    Einarsen, Karoline; Calloe, Kirstine; Grunnet, Morten

    2009-01-01

    Kv11 potassium channels are important for regulation of the membrane potential. Kv11.2 and Kv11.3 are primarily found in the nervous system, where they most likely are involved in the regulation of neuronal excitability. Two isoforms of human Kv11.2 have been published so far. Here, we present...... current characteristics of the isoforms presented in this work may contribute to the regulation of neuronal excitability....

  7. Analysis of disturbances in the 15 kV traction power network by means of simulation calculations and tests; Analyse von Stoerungen im 15-kV-Bahnenergienetz durch Simulationsrechnungen und Versuche

    Energy Technology Data Exchange (ETDEWEB)

    Aeberhard, Martin; Basler, Egon [SBB AG, Zollikofen (Switzerland). Infrastruktur Energie

    2013-06-15

    Being one of the most important rail junctions of Switzerland, Olten is powered by a substation the 132 kV feeder of which features a number of structural weaknesses. Simulations were used to analyse the effects of electrical equipment failures in this substation on train operation, the nearby 15 kV overhead line system and the loads adjacent substations are subjected to. By considering all risks, a critical case of train operation with different load scenarios was investigated. The article includes a comparison between simulated and measured data and presents the conclusions that were drawn from the actions taken in respect of the future system design. (orig.)

  8. The anticonvulsant retigabine suppresses neuronal Kv2-mediated currents

    DEFF Research Database (Denmark)

    Stas, Jeroen I; Bocksteins, Elke; Jensen, Camilla S

    2016-01-01

    Enhancement of neuronal M-currents, generated through KV7.2-KV7.5 channels, has gained much interest for its potential in developing treatments for hyperexcitability-related disorders such as epilepsy. Retigabine, a KV7 channel opener, has proven to be an effective anticonvulsant and has recently...

  9. Proximity to overhead power lines and childhood leukaemia

    DEFF Research Database (Denmark)

    Amoon, Aryana T; Crespi, Catherine M; Ahlbom, Anders

    2018-01-01

    BACKGROUND: Although studies have consistently found an association between childhood leukaemia risk and magnetic fields, the associations between childhood leukaemia and distance to overhead power lines have been inconsistent. We pooled data from multiple studies to assess the association with d...

  10. Communication overhead on the Intel iPSC-860 hypercube

    Science.gov (United States)

    Bokhari, Shahid H.

    1990-01-01

    Experiments were conducted on the Intel iPSC-860 hypercube in order to evaluate the overhead of interprocessor communication. It is demonstrated that: (1) contrary to popular belief, the distance between two communicating processors has a significant impact on communication time, (2) edge contention can increase communication time by a factor of more than 7, and (3) node contention has no measurable impact.

  11. Authentication and consensus overhead in vehicular ad hoc networks

    NARCIS (Netherlands)

    Petit, Jonathan; Mammeri, Zoubir

    Vehicular ad hoc networks aim at increasing passenger safety by exchanging warning messages between vehicles wirelessly. A main challenge is to resist to various malicious abuses and security attacks. However, any security mechanism comes with overhead. We analyze how the authentication algorithm

  12. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  13. 23 CFR 140.907 - Overhead and indirect construction costs.

    Science.gov (United States)

    2010-04-01

    ... accounting principles; (2) The costs included in the distribution are limited to costs actually incurred by...), part 31, Contract Cost Principles and Procedures, relating to contracts with commercial organizations... 23 Highways 1 2010-04-01 2010-04-01 false Overhead and indirect construction costs. 140.907...

  14. Ergonomic evaluation of a wearable assistive device for overhead work.

    Science.gov (United States)

    Rashedi, Ehsan; Kim, Sunwook; Nussbaum, Maury A; Agnew, Michael J

    2014-01-01

    Overhead work is an important risk factor for upper extremity (UE) musculoskeletal disorders. We examined the potential of a mechanical arm and an exoskeletal vest as a wearable assistive device (WADE) for overhead work. Twelve participants completed 10 minutes of simulated, intermittent overhead work, using each of three payloads (1.1, 3.4 and 8.1 kg) and with/without the WADE. Ratings of perceived discomfort (RPDs) and electromyography (EMG) were obtained for the upper arms, shoulders and low back. Using the WADE, UE RPDs decreased by ∼50% with the heavier payloads, whereas smaller (∼25%) and non-significant increases in low-back RPDs were found and were relatively independent of payload. Changes in RPDs with WADE use were consistent with physical demands indicated by EMG, though EMG-based differences in fatigue were less apparent. Participants generally preferred using the WADE, particularly with heavier payloads. These results supported the potential utility of a WADE as an intervention for overhead work.

  15. Designing concept on lightning protection of overhead power distribution line

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Shigeru [Central Research Institute of Electric Power Industry, Kanagawa-ken (Japan)], E-mail: yokoyama@criepi.denken.or.jp

    2007-07-01

    The principle is shown for lightning protection of power distribution lines taking the effects of surge arresters, overhead ground wires and their combined use into consideration. Moreover an outline of a rational design method targeting direct lightning hits, induced over voltages and back flow currents from high structures. (author)

  16. Composite Extension Finite Fields for Low Overhead Network Coding

    DEFF Research Database (Denmark)

    Heide, Janus; Roetter, Daniel Enrique Lucani

    2015-01-01

    Although Network Coding (NC) has been proven to increase throughput and reliability in communication networks, its adoption is typically hindered by the additional complexity it introduces at various nodes in the network and the overhead to signal the coding coefficients associated with each code...

  17. Transmission and capacity pricing and constraints

    International Nuclear Information System (INIS)

    Fusco, M.

    1999-01-01

    A series of overhead viewgraphs accompanied this presentation which discussed the following issues regarding the North American electric power industry: (1) capacity pricing transmission constraints, (2) nature of transmission constraints, (3) consequences of transmission constraints, and (4) prices as market evidence. Some solutions suggested for pricing constraints included the development of contingent contracts, back-up power in supply regions, and new line capacity construction. 8 tabs., 20 figs

  18. Step-by-step application methodology in practical KEPCO 22.9kV bus-bar system

    International Nuclear Information System (INIS)

    Yoon, Jae-young; Lee, Seung-yeol

    2010-01-01

    With the increase of power demand and the progress of power industry deregulation, the transmission and distribution systems will have more complicated problems by the influence of curtailing investment and the NIMBY phenomena in overall power systems. [1-2] It is expected that the route length per MW demand of South Korea will decrease gradually from 0.6[C-km/MW] to 0.53[C-km/MW] in 2010.[3] This comes up to a real serious problem from system planning and operation viewpoints. HTS technologies related to power system have properties to solve these complex transmission and distribution constraints, especially for metropolitan area, in the future. As the HTS technology has developed, the HTS cable technology can be the most effective alternative to solve the future expected power network constraints. This paper describes the application methodology of developing 22.9kV HTS cable by CAST for practical distribution system. 22.9kV HTS cable under development with step-by-step application methodology can substitute the existing and planning conventional 154kV cable.[4-5] If this scheme is applied, part of downtown 154kV substation of metropolitan city such as Seoul can be changed into 22.9kV switching station. Additionally, it can give huge economic, environmental benefits to all of the concerned authorities.

  19. The subfamily-specific interaction between Kv2.1 and Kv6.4 subunits is determined by interactions between the N- and C-termini.

    Directory of Open Access Journals (Sweden)

    Elke Bocksteins

    Full Text Available The "silent" voltage-gated potassium (KvS channel subunit Kv6.4 does not form electrically functional homotetramers at the plasma membrane but assembles with Kv2.1 subunits, generating functional Kv2.1/Kv6.4 heterotetramers. The N-terminal T1 domain determines the subfamily-specific assembly of Kv1-4 subunits by preventing interactions between subunits that belong to different subfamilies. For Kv6.4, yeast-two-hybrid experiments showed an interaction of the Kv6.4 N-terminus with the Kv2.1 N-terminus, but unexpectedly also with the Kv3.1 N-terminus. We confirmed this interaction by Fluorescence Resonance Energy Transfer (FRET and co-immunoprecipitation (co-IP using N-terminal Kv3.1 and Kv6.4 fragments. However, full-length Kv3.1 and Kv6.4 subunits do not form heterotetramers at the plasma membrane. Therefore, additional interactions between the Kv6.4 and Kv2.1 subunits should be important in the Kv2.1/Kv6.4 subfamily-specificity. Using FRET and co-IP approaches with N- and C-terminal fragments we observed that the Kv6.4 C-terminus physically interacts with the Kv2.1 N-terminus but not with the Kv3.1 N-terminus. The N-terminal amino acid sequence CDD which is conserved between Kv2 and KvS subunits appeared to be a key determinant since charge reversals with arginine substitutions abolished the interaction between the N-terminus of Kv2.1 and the C-terminus of both Kv2.1 and Kv6.4. In addition, the Kv6.4(CKv3.1 chimera in which the C-terminus of Kv6.4 was replaced by the corresponding domain of Kv3.1, disrupted the assembly with Kv2.1. These results indicate that the subfamily-specific Kv2.1/Kv6.4 heterotetramerization is determined by interactions between Kv2.1 and Kv6.4 that involve both the N- and C-termini in which the conserved N-terminal CDD sequence plays a key role.

  20. Effects of haloperidol on Kv4.3 potassium channels.

    Science.gov (United States)

    Lee, Hong Joon; Sung, Ki-Wug; Hahn, Sang June

    2014-10-05

    Haloperidol is commonly used in clinical practice to treat acute and chronic psychosis, but it also has been associated with adverse cardiovascular events. We investigated the effects of haloperidol on Kv4.3 currents stably expressed in CHO cells using a whole-cell patch-clamp technique. Haloperidol did not significantly inhibit the peak amplitude of Kv4.3, but accelerated the decay rate of inactivation of Kv4.3 in a concentration-dependent manner. Thus, the effects of haloperidol on Kv4.3 were estimated from the integral of the Kv4.3 currents during the depolarization pulse. The Kv4.3 was decreased by haloperidol in a concentration-dependent manner with an IC50 value of 3.6 μM. Haloperidol accelerated the decay rate of Kv4.3 inactivation and activation kinetics in a concentration-dependent manner, thereby decreasing the time-to-peak. Haloperidol shifted the voltage dependence of the steady-state activation and inactivation of Kv4.3 in a hyperpolarizing direction. Haloperidol also caused an acceleration of the closed-state inactivation of Kv4.3. Haloperidol produced a use-dependent block of Kv4.3, which was accompanied by a slowing of recovery from the inactivation of Kv4.3. These results suggest that haloperidol blocks Kv4.3 by both interacting with the open state of Kv4.3 channels during depolarization and accelerating the closed-state inactivation at subthreshold membrane potentials. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Overhead remote handling systems for the process facility modifications project

    International Nuclear Information System (INIS)

    Wiesener, R.W.; Grover, D.L.

    1987-01-01

    Each of the cells in the process facility modifications (PFM) project complex is provided with a variety of general purpose remote handling equipment including bridge cranes, monorail hoist, bridge-mounted electromechanical manipulator (EMM) and an overhead robot used for high efficiency particulate air (HEPA) filter changeout. This equipment supplements master-slave manipulators (MSMs) located throughout the complex to provide an overall remote handling system capability. The overhead handling equipment is used for fuel and waste material handling operations throughout the process cells. The system also provides the capability for remote replacement of all in-cell process equipment which may fail or be replaced for upgrading during the lifetime of the facility

  2. Removal of the Materials Test Reactor overhead working reservoir

    International Nuclear Information System (INIS)

    Lunis, B.C.

    1975-10-01

    Salient features of the removal of an excessed contaminated facility, the Materials Test Reactor (MTR) overhead working reservoir (OWR) from the Test Reactor Area to the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory are described. The 125-ton OWR was an overhead 160,000-gallon-capacity tank approximately 193 feet high which supplied cooling water to the MTR. Radiation at ground level beneath the tank was 5 mR/hr and approximately 600 mR/hr at the exterior surface of the tank. Sources ranging from 3 R/hr to in excess of 500 R/hr exist within the tank. The tank interior is contaminated with uranium, plutonium, and miscellaneous fission products. The OWR was lowered to ground level with the use of explosive cutters. Dismantling, decontamination, and disposal were performed by Aerojet Nuclear Company maintenance forces

  3. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  4. Single channel and WDM transmission of 28 Gbaud zero-guard-interval CO-OFDM.

    Science.gov (United States)

    Zhuge, Qunbi; Morsy-Osman, Mohamed; Mousa-Pasandi, Mohammad E; Xu, Xian; Chagnon, Mathieu; El-Sahn, Ziad A; Chen, Chen; Plant, David V

    2012-12-10

    We report on the experimental demonstration of single channel 28 Gbaud QPSK and 16-QAM zero-guard-interval (ZGI) CO-OFDM transmission with only 1.34% overhead for OFDM processing. The achieved transmission distance is 5120 km for QPSK assuming a 7% forward error correction (FEC) overhead, and 1280 km for 16-QAM assuming a 20% FEC overhead. We also demonstrate the improved tolerance of ZGI CO-OFDM to residual inter-symbol interference compared to reduced-guard-interval (RGI) CO-OFDM. In addition, we report an 8-channel wavelength-division multiplexing (WDM) transmission of 28 Gbaud QPSK ZGI CO-OFDM signals over 4160 km.

  5. 30 CFR 56.16015 - Work or travel on overhead crane bridges.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work or travel on overhead crane bridges. 56... Materials Storage and Handling § 56.16015 Work or travel on overhead crane bridges. No person shall work from or travel on the bridge of an overhead crane unless the bridge is provided with substantial...

  6. 30 CFR 57.16015 - Work or travel on overhead crane bridges.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work or travel on overhead crane bridges. 57... MINES Materials Storage and Handling § 57.16015 Work or travel on overhead crane bridges. No person shall work from or travel on the bridge of an overhead crane unless the bridge is provided with...

  7. Structural Design of Two-Cylinder Single Overhead Camshaft

    Science.gov (United States)

    Zhao, Yuxia; Zhang, Kangsheng; Di, Jiejian

    2018-01-01

    Due to the higher performance demand, the camshaft is the key driving part in the engine. Because it is eccentric circular section part, it is very difficult to design and manufacture this kind of axial parts. Take two-cylinder single overhead camshaft for an example, the entire process of camshaft design is analyzed. The practice has proved that the method has simple, flexible and efficient advantages, and it can greatly shorten the design of artificial computing time.

  8. Modeling the Virtual Machine Launching Overhead under Fermicloud

    Energy Technology Data Exchange (ETDEWEB)

    Garzoglio, Gabriele [Fermilab; Wu, Hao [Fermilab; Ren, Shangping [IIT, Chicago; Timm, Steven [Fermilab; Bernabeu, Gerard [Fermilab; Noh, Seo-Young [KISTI, Daejeon

    2014-11-12

    FermiCloud is a private cloud developed by the Fermi National Accelerator Laboratory for scientific workflows. The Cloud Bursting module of the FermiCloud enables the FermiCloud, when more computational resources are needed, to automatically launch virtual machines to available resources such as public clouds. One of the main challenges in developing the cloud bursting module is to decide when and where to launch a VM so that all resources are most effectively and efficiently utilized and the system performance is optimized. However, based on FermiCloud’s system operational data, the VM launching overhead is not a constant. It varies with physical resource (CPU, memory, I/O device) utilization at the time when a VM is launched. Hence, to make judicious decisions as to when and where a VM should be launched, a VM launch overhead reference model is needed. The paper is to develop a VM launch overhead reference model based on operational data we have obtained on FermiCloud and uses the reference model to guide the cloud bursting process.

  9. Kv7 channels can function without constitutive calmodulin tethering.

    Directory of Open Access Journals (Sweden)

    Juan Camilo Gómez-Posada

    Full Text Available M-channels are voltage-gated potassium channels composed of Kv7.2-7.5 subunits that serve as important regulators of neuronal excitability. Calmodulin binding is required for Kv7 channel function and mutations in Kv7.2 that disrupt calmodulin binding cause Benign Familial Neonatal Convulsions (BFNC, a dominantly inherited human epilepsy. On the basis that Kv7.2 mutants deficient in calmodulin binding are not functional, calmodulin has been defined as an auxiliary subunit of Kv7 channels. However, we have identified a presumably phosphomimetic mutation S511D that permits calmodulin-independent function. Thus, our data reveal that constitutive tethering of calmodulin is not required for Kv7 channel function.

  10. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    Directory of Open Access Journals (Sweden)

    Huiwen He

    2017-01-01

    Full Text Available The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.

  11. Kv1.1 knock-in ataxic mice exhibit spontaneous myokymic activity exacerbated by fatigue, ischemia and low temperature.

    Science.gov (United States)

    Brunetti, Orazio; Imbrici, Paola; Botti, Fabio Massimo; Pettorossi, Vito Enrico; D'Adamo, Maria Cristina; Valentino, Mario; Zammit, Christian; Mora, Marina; Gibertini, Sara; Di Giovanni, Giuseppe; Muscat, Richard; Pessia, Mauro

    2012-09-01

    Episodic ataxia type 1 (EA1) is an autosomal dominant neurological disorder characterized by myokymia and attacks of ataxic gait often precipitated by stress. Several genetic mutations have been identified in the Shaker-like K(+) channel Kv1.1 (KCNA1) of EA1 individuals, including V408A, which result in remarkable channel dysfunction. By inserting the heterozygous V408A, mutation in one Kv1.1 allele, a mouse model of EA1 has been generated (Kv1.1(V408A/+)). Here, we investigated the neuromuscular transmission of Kv1.1(V408A/+) ataxic mice and their susceptibility to physiologically relevant stressors. By using in vivo preparations of lateral gastrocnemius (LG) nerve-muscle from Kv1.1(+/+) and Kv1.1(V408A/+) mice, we show that the mutant animals exhibit spontaneous myokymic discharges consisting of repeated singlets, duplets or multiplets, despite motor nerve axotomy. Two-photon laser scanning microscopy from the motor nerve, ex vivo, revealed spontaneous Ca(2+) signals that occurred abnormally only in preparations dissected from Kv1.1(V408A/+) mice. Spontaneous bursting activity, as well as that evoked by sciatic nerve stimulation, was exacerbated by muscle fatigue, ischemia and low temperatures. These stressors also increased the amplitude of compound muscle action potential. Such abnormal neuromuscular transmission did not alter fiber type composition, neuromuscular junction and vascularization of LG muscle, analyzed by light and electron microscopy. Taken together these findings provide direct evidence that identifies the motor nerve as an important generator of myokymic activity, that dysfunction of Kv1.1 channels alters Ca(2+) homeostasis in motor axons, and also strongly suggest that muscle fatigue contributes more than PNS fatigue to exacerbate the myokymia/neuromyotonia phenotype. More broadly, this study points out that juxtaparanodal K(+) channels composed of Kv1.1 subunits exert an important role in dampening the excitability of motor nerve axons during

  12. Full Scale Test on a 100km, 150kV AC Cable

    DEFF Research Database (Denmark)

    Faria da Silva, Filipe Farria; Wiechowski, W.; Bak, Claus Leth

    2010-01-01

    phenomena is conducted. The cases analysed in this paper are: Zero-missing phenomenon, Ferranti effect, energisation transient, effect of the cable's connection in the busbar voltage and cable disconnection. For all the phenomena described in the paper measurement data are presented and it is verified......This paper presents some of the results obtained from the electrical measurements on a 99.7 km, 150 kV three-phase AC cable, connecting 215 MW offshore wind farm Horns Rev 2, located in Denmark west coast, to Denmark's 400 kV transmission network. The measurements were performed at nominal voltage...... if the obtained results are in accordance with the theory and also with simulations performed in PSCAD/EMTDC. With the exception of the cable disconnection, for all the remaining cases introduced in this paper the measurements confirmed the theoretical expectations. Depending on the cable disconnection sequence...

  13. Internal services simulation control in 220/110kV power transformer station Mintia

    Science.gov (United States)

    Ciulica, D.; Rob, R.

    2018-01-01

    The main objectives in developing the electric transport and distribution networks infrastructure are satisfying the electric energy demand, ensuring the continuity of supply to customers, minimizing electricity losses in the transmission and distribution networks of public interest. This paper presents simulations in functioning of the internal services system 400/230 V ac in the 220/110 kV power transformer station Mintia. Using simulations in Visual Basic, the following premises are taken into consideration. All the ac consumers of the 220/110 kV power transformer station Mintia will be supplied by three 400/230 V transformers for internal services which can mutual reserve. In case of damaging at one transformer, the others are able to assume the entire consumption using automatic release of reserves. The simulation program studies three variants in which the continuity of supply to customers are ensured. As well, by simulations, all the functioning situations are analyzed in detail.

  14. Study and field verification of the effects of removing closing resistors from 500 kV circuit breakers

    International Nuclear Information System (INIS)

    Selin, D.A.; Agrawal, B.L.; Farmer, R.G.; Demcko, J.A.

    1992-01-01

    Closing resistors in EHV circuit breakers are frequently used to reduce switching transients on lines thus preventing flashovers during line energization. Maintenance and failures of such closing resistors can be costly and reduce transmission system reliability. For these reasons, APS conducted an investigation into the technical feasibility of operating its 500 kV without closing resistors. This paper describes study results of removing closing resistors from 500 kV breakers in a system which employs older technology silicon carbide type surge arresters. The paper also describes results of field tests of the expected flashover rates calculated in the study. These field tests involve repeatedly energizing a 258 mile 500 kV line using a breaker in which the closing resistors are disabled. Transient overvoltages captured during the tests are compared with predicted overvoltages. The study concludes that closing resistors may be removed from the subject system without unacceptable consequences

  15. Molecular and functional characterization of Kv7 K+ channel in murine gastrointestinal smooth muscles

    DEFF Research Database (Denmark)

    Jepps, Thomas Andrew; Greenwood, Iain A; Moffatt, James D

    2009-01-01

    that K(v)7.x especially K(v)7.4 and K(v)7.5 are expressed in different regions of the murine gastrointestinal tract and blockers of K(v)7 channels augment inherent contractile activity. Drugs that selectively block K(v)7.4/7.5 might be promising therapeutics for the treatment of motility disorders...

  16. Shoulder injuries in overhead sports; Schultergelenkverletzungen bei Ueberkopfsportarten

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, K. [Technische Universitaet Muenchen (Germany). Institut fuer Roentgendiagnostik

    2010-05-15

    Overhead sport places great demands on the shoulder joint. Shoulder pain in overhead athletes and throwers can in the majority of cases be attributed to lesions resulting from chronic overuse of tendons and capsuloligamentous structures or to sequels of microinstability and secondary impingement. Due to its great impact on therapeutic decisions, imaging in athletes with unclear shoulder pain is a challenge. In this connection, magnetic resonance (MR) arthrography represents the cross-sectional imaging modality of first choice, as it allows depiction and exclusion of pathologic alterations of all relevant joint structures with sufficient confidence. This article reviews the biomechanical and clinical aspects and MR arthrographic features of the most common shoulder pathologies in overhead athletes, including biceps tendinopathy, superior labral anterior-posterior (SLAP) lesions, rotator cuff lesions, as well as extrinsic and intrinsic impingement syndromes. (orig.) [German] Ueberkopfsportarten stellen grosse Anforderungen an das Schultergelenk. Schulterbeschwerden bei Ueberkopf- und Wurfsportlern koennen in der Mehrzahl der Faelle auf eine chronische Ueberlastung von Sehnen und Kapsel-Band-Strukturen oder auf die Folgen einer Mikroinstabilitaet und sekundaerer Impingementsyndrome zurueckgefuehrt werden. Wegen ihres grossen Einflusses auf die Therapieentscheidung stellt die Bildgebung bei Athleten mit unklaren Schulterbeschwerden eine Herausforderung dar. Die MR-Arthrographie ist in diesem Zusammenhang als Schnittbildverfahren der ersten Wahl anzusehen, da sie den Nachweis bzw. Ausschluss pathologischer Veraenderungen aller relevanten Gelenkstrukturen mit ausreichender Sicherheit ermoeglicht. Dieser Artikel gibt eine Uebersicht ueber biomechanische und klinische Aspekte sowie MR-arthrographische Befunde der haeufigsten Schultergelenkpathologien bei Ueberkopfsportlern, wie Bizepstendinopathie, Superior-labral-anterior-posterior- (SLAP-)Laesionen, Laesionen der

  17. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  18. Analysis of the 35 KV substation secondary system

    Science.gov (United States)

    Zhao, Yong; Jiang, Jianguo; Jiang, Chunlei; Ren, Shuang; Liu, Songbin

    2017-04-01

    This paper analyzes the status of the two system of some 35KV users' substation in Daqing oil field, the deficiencies of the two system of the existing 35KV substation are found out. And put forward the opinion of acceptance in the future work. I hope it can able to work in the future on the protection of professional help.

  19. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    . The comparison shows that results obtained used both types of the cores are the same, so it is concluded that both cores can be used for harmonic measurements. Low-inductance resistors are introduced in the secondary circuits, in series with the metering and protective relaying. On those resistors, the harmonic......Some time ago, Energinet.dk, the Transmission System Operator of the 150 kV and 400 kV transmission network in Denmark, had experienced operational malfunctions of some of the measuring and protection equipment. Also an overloading of a harmonic filter has been reported, and therefore, a need...... end only so the ground is not used as a return path. A way to reduce the capacitive coupling is to provide shielding. Harmonic currents are measured using the conventional inductive voltage transformers. Both protective and metering cores were compared if they could be used for harmonic measurements...

  20. Rehabilitation of the Overhead Athlete’s Elbow

    Science.gov (United States)

    Wilk, Kevin E.; Macrina, Leonard C.; Cain, E. Lyle; Dugas, Jeffrey R.; Andrews, James R.

    2012-01-01

    The activities required during overhead sports, particularly during baseball pitching, produce large forces at the elbow joint. Injuries to the elbow joint frequently occur in the overhead athlete because of the large amount of forces observed during the act of throwing, playing tennis, or playing golf. Injuries may result because of repetitive overuse, leading to tissue failure. Rehabilitation following injury or surgery to the throwing elbow is vital to fully restore normal function and return the athlete to competition as quickly and safely as possible. Rehabilitation of the elbow, whether following injury or postsurgical, must follow a progressive and sequential order, building on the previous phase, to ensure that healing tissues are not compromised. Emphasis is placed on restoring full motion, muscular strength, and neuromuscular control while gradually applying loads to healing tissue. In addition, when one is creating a rehabilitation plan for athletes, it is imperative to treat the entire upper extremity, core, and legs to create and dissipate the forces generated at each joint. PMID:23016113

  1. Ingledow 500 kV substation : using mixed technology switchgear solutions for replacement

    Energy Technology Data Exchange (ETDEWEB)

    Wallner, C.; Glaubitz, P. [Siemens AG, Munich (Germany); Messinger, T. [British Columbia Transmission Corp., Vancouver, BC (Canada)

    2008-07-01

    The reliability of the 500 kV equipment at the Ingledow substation operated by BC Hydro Transmission System is of critical importance due to the energy interchange with the Bonneville Power Authority in the United States and the major role of the substation in serving the energy needs of British Columbia's densely populated Lower Mainland. Presently, the 500 kV switchyard includes 10 airblast circuit breakers and the associated current transformers which are all approaching their end of service-life. In response to environmental and safety concerns, the British Columbia Transmission Corporation adopted a policy whereby new oil-filled transformers are no longer acceptable, and the replacement of existing oil-filled transformers must be oil-free. The result is that the current transformers must be either bushing-type or sulphur-hexafluoride (SF6) type. The replacement strategies for the substation equipment consider economical, environmental and seismic issues. They have just as strong an influence on the decision process as the technical, operational and reliability aspects for the particular case or switchgear replacement in the transmission system. The Ingledow case demonstrates the advantages of using mixed technology switchgear, with its compact design flowing from gas insulated switchgear (GIS) for replacement of equipment in an outdoor switchyard. The advantages of the MTS in this case offer the possibility of future reconfiguration to improve the system reliability within the existing switchyard space. 3 refs., 5 figs.

  2. The influence of the 220 kv and 66 kv power electric systems and the subsystem of their servitude range in the 'chaco central' ecosystem in Paraguay; Relacion de tendido electrico de 220 kV y 66kV en el ecosistema del chaco central del Paraguay y el subsistema de su franja de servidumbre

    Energy Technology Data Exchange (ETDEWEB)

    Acosta E, Hugo Cesar [ANDE - Administracion Nacional de Electricidad, Assuncion (Paraguay)

    2001-07-01

    According to the report from DOP/EL, in a medium period of time it has been registered nine disconnections of the 66 kv power transmission line located in the Chaco zone occurred in the nocturnal period. Those disconnections affected negatively the milky processes of Colinas Menonitas, deteriorating more than 20,000 liters of milk for each cut of the electric energy service. DMA/IM has accomplished a investigation job together with DOM/FO and has found the main reasons for those disconnections, so based on them it has recommended possible solutions related to the problem.

  3. Development of sensorless easy-to-use overhead crane system via simulation based control

    Science.gov (United States)

    Tagawa, Yasutaka; Mori, Yoshihito; Wada, Masaomi; Kawajiri, Eisaku; Nouzuka, Kazuma

    2016-09-01

    This paper describes the newly developed overhead crane which has a sensorless vibration control system. Generally, loads which are carried by the overhead cranes are easy to vibrate and only skilled people can operate the cranes. Therefore, a lot of studies have been done to solve this problem by using feedback control with vibration sensors. However vibration sensors often break down in severe industrial environment and more reliable control systems are required. For this reason, we have been developing sensorless control system for overhead cranes. In this paper, we firstly introduce basic idea of simulation based control which is called IDCS, then overview and modeling of the overhead crane is presented. Next, the control system design of the overhead crane is discussed, and experimental results are shown for real overhead crane with 2 axes.

  4. The Motion Planning of Overhead Crane Based on Suppressing Payload Residual Swing

    Directory of Open Access Journals (Sweden)

    Liu Hua-sen

    2016-01-01

    Full Text Available Since the overhead crane system is subject to under actuation system due to that overhead crane and payload are connected by flexibility wire rope. The payload generates residual swing when the overhead crane is accelerating/ decelerating the motions. This may cause trouble for the payload precise positioning and motion planning. Hence, an optimization input shaping control method is presented to reduce the under actuated overhead crane’s payload swing caused via the inertia force. The dynamic model of the overhead crane is proposed according to the physics structure of the crane. The input shaper based on the motion planning of the crane is used as the feed forward input to suppress payload residual swing. Simulation and experiment results indicate that the ZV input shaper and ZVD input shaper can reduce the payload swing of the overhead crane.

  5. Development of a 400 kV 80 mA Cockcroft-Walton power supply and 12 kW isolation transformer systems for neutron generators

    Science.gov (United States)

    Lu, X.; Chen, S.; Zhang, Y.; Huang, Z.; Ma, Z.; Yao, Z.

    2017-06-01

    A 400 kV 80 mA Cockcroft-Walton power supply driven by 2.5 kHz frequency, and 12 kW isolation transformer systems are developed for an intense DD/DT neutron generator. The design, construction, and testing of the high voltage (HV) power supply and isolation transformer systems are detailed reported. The structure of step-up transformers can make the potential distribution uniform, and auxiliary coils of the isolation transformers can improve the power transmission efficiency significantly. The testing results show that the HV power supply can reach 400 kV, and the isolation transformer systems can withstand 400 kV voltages and its power transmission efficiency is about 98.1%.

  6. Aberration-corrected STEM/TEM imaging at 15 kV

    International Nuclear Information System (INIS)

    Sasaki, Takeo; Sawada, Hidetaka; Hosokawa, Fumio; Sato, Yuta; Suenaga, Kazu

    2014-01-01

    The performance of aberration-corrected (scanning) transmission electron microscopy (S/TEM) at an accelerating voltage of 15 kV was evaluated in a low-voltage microscope equipped with a cold-field emission gun and a higher-order aberration corrector. Aberrations up to the fifth order were corrected by the aberration measurement and auto-correction system using the diffractogram tableau method in TEM and Ronchigram analysis in STEM. TEM observation of nanometer-sized particles demonstrated that aberrations up to an angle of 50 mrad were compensated. A TEM image of Si[110] exhibited lattice fringes with a spacing of 0.192 nm, and the power spectrum of the image showed spots corresponding to distances of 0.111 nm. An annular dark-field STEM image of Si[110] showed lattice fringes of (111) and (22¯0) planes corresponding to lattice distances of 0.314 nm and 0.192 nm, respectively. At an accelerating voltage of 15 kV, the developed low-voltage microscope achieved atomic-resolution imaging with a small chromatic aberration and a large uniform phase. - Highlights: • Aberration-corrected STEM/TEM imaging at 15 kV demonstrated lattice fringes of Si[110] single crystal with a spacing of 0.192 nm. • To achieve this performance at a lower accelerating voltage, uniform phase area over 50 mrad is mandatory in Ronchigram and Diffractogram tableau. • This means a higher-order aberration of six-fold astigmatism should be compensated. • In addition, decreasing the effect of chromatic aberration plays an important role for improving the performance of linear scattering component at 15 kV TEM

  7. An ultrasonic guided wave approach for the inspection of overhead transmission line cables

    DEFF Research Database (Denmark)

    Yücel, Mehmet K.; Legg, Mathew; Kappatos, Vasileios

    2017-01-01

    as a non-destructive testing technique is well established for simple geometries such as plates, pipes, and rods. However, its application for multi-wire cables is still in development. In this study, ultrasonic guided waves excited by a shear mode transducer collar are utilised as a defect detection...... technique for untensioned aluminium conductor steel reinforced cable specimens. The identification and analysis of wave propagation for a broad range of frequencies is performed using a laser scanning vibrometer, and the effect of defect size on wave propagation is studied. Signal processing algorithms...

  8. β-Secretase BACE1 Promotes Surface Expression and Function of Kv3.4 at Hippocampal Mossy Fiber Synapses.

    Science.gov (United States)

    Hartmann, Stephanie; Zheng, Fang; Kyncl, Michele C; Karch, Sandra; Voelkl, Kerstin; Zott, Benedikt; D'Avanzo, Carla; Lomoio, Selene; Tesco, Giuseppina; Kim, Doo Y; Alzheimer, Christian; Huth, Tobias

    2018-04-04

    The β-secretase β-site APP-cleaving enzyme 1 (BACE1) is deemed a major culprit in Alzheimer's disease, but accumulating evidence indicates that there is more to the enzyme than driving the amyloidogenic processing of the amyloid precursor protein. For example, BACE1 has emerged as an important regulator of neuronal activity through proteolytic and, most unexpectedly, also through nonproteolytic interactions with several ion channels. Here, we identify and characterize the voltage-gated K + channel 3.4 (Kv3.4) as a new and functionally relevant interaction partner of BACE1. Kv3.4 gives rise to A-type current with fast activating and inactivating kinetics and serves to repolarize the presynaptic action potential. We found that BACE1 and Kv3.4 are highly enriched and remarkably colocalized in hippocampal mossy fibers (MFs). In BACE1 -/- mice of either sex, Kv3.4 surface expression was significantly reduced in the hippocampus and, in synaptic fractions thereof, Kv3.4 was specifically diminished, whereas protein levels of other presynaptic K + channels such as K Ca 1.1 and K Ca 2.3 remained unchanged. The apparent loss of presynaptic Kv3.4 affected the strength of excitatory transmission at the MF-CA3 synapse in hippocampal slices of BACE1 -/- mice when probed with the Kv3 channel blocker BDS-I. The effect of BACE1 on Kv3.4 expression and function should be bidirectional, as predicted from a heterologous expression system, in which BACE1 cotransfection produced a concomitant upregulation of Kv3.4 surface level and current based on a physical interaction between the two proteins. Our data show that, by targeting Kv3.4 to presynaptic sites, BACE1 endows the terminal with a powerful means to regulate the strength of transmitter release. SIGNIFICANCE STATEMENT The β-secretase β-site APP-cleaving enzyme 1 (BACE1) is infamous for its crucial role in the pathogenesis of Alzheimer's disease, but its physiological functions in the intact nervous system are only gradually

  9. On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberto Campos de; Oliveira, Mario Cesar Santos de [FURNAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The energy produced at the Itaipu Power Plant for the Brazilian Interconnected System is transmitted through two different transmission system: -HVDC system, with two bipoles of +- 600 kV, 6300 MW which connect the substation of Foz do Iguacu in the State of Parana, to substation of Ibiuna in the State of Sao Paulo, transmitting the energy generated in 50 Hz units. This system was entirely commissioned on september of 1987. (author) 3 refs., 5 figs.

  10. Use of TCSR with Split Windings for Shortening the Spar Cycle Time in 500 kV Lines

    Energy Technology Data Exchange (ETDEWEB)

    Matinyan, A. M., E-mail: al-drm@mail.ru; Peshkov, M. V.; Karpov, V. N.; Alekseev, N. A. [JSC “R& D Center at Federal Grid Company of Unified Power System,” (Russian Federation)

    2017-01-15

    The arc-fault recharge phenomenon in single-phase automatic reclosure (SPAR) of a line is examined. Abrief description is given of the design of a 500 kV thyristor controlled shunt reactor (TCSR) with split valve-side windings. This type of TCSR is shown to effectively quench a single-phase arc fault in a power transmission line and shortens the SPAR cycle time.

  11. [The story of K.V. Tjellesen].

    Science.gov (United States)

    Clemmensen, Peter

    2005-01-01

    This is the story about a Danish pharmaceutical wholesaler. The story begins in 1909 in some basement rooms located in Vester Boulevard 42 (which was later to become the Boulevard of H.C. Andersen) in Copenhagen. The founder of the company, pharmacist Knud Valdemar Tjellesen, lived in the very same building. In the beginning, the company mainly sold chemicals and produced and sold chemical-technical products. In 1930, K.V. Tjellesen became the proprietor of the pharmacy Sct. Johannes Apotek situated in Fredensgade 5, Nørrebro in Copenhagen. The company then moved into some offices that were located just behind the pharmacy. Already in 1918, K.V. Tjellesen traded pharmaceutical specialties, which were imported, to a certain extent, from Germany through a purchasing office in Hamburg. In 1938, the son of Knud Valdemar Tjellesen, pharmacist Paul Tjellesen, joined the wholesale company charged with the primary task of intensifying the sale of the company's international agency products. At the same time, the general partnership K.V. Tjellesen was founded. In the time leading up to the Second World War and during this time, business was of course complicated by currency and import restrictions, and it was very difficult to make deliveries to the pharmacies. In Copenhagen, the articles were delivered by 10-12 bicycle delivery boys. In the beginning, the wholesale company mainly catered for Copenhagen and Zealand, but due to the excellent performance of Paul Tjellesen, more and more customers emerged in the rest of the country. In 1954, the company moved to Niels Ebbesens Vej 29 in Frederiksberg given the need for larger facilities. In 1963, an increased space requirement, once again, forced the company to buy one of the neighbouring buildings on Niels Ebbesens Vej and H.C. Orsteds Vej. For many years after, H.C. Orsteds Vej 22 was the official address of the company. After more than 45 years in the company, Paul Tjellesen agreed with his son-in-law Peter Sch

  12. Solution of K-V envelope equations

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1995-04-01

    The envelope equations for a KV beam with space charge have been analyzed systematically by an e expansion followed by integrations. The focusing profile as a function of axial length is assumed to be symmetric but otherwise arbitrary. Given the bean current, emittance, and peak focusing field, we find the envelopes a(s) and b(s) and obtain , a max , σ, and σ 0 . Explicit results are presented for various truncations of the expansion. The zeroth order results correspond to those from the well-known smooth approximation; the same convenient format is retained for the higher order cases. The first order results, involving single correction terms, give 3--10 times better accuracy and are good to ∼1% at σ 0 = 70 degree. Third order gives a factor of 10--30 improvement over the smooth approximation and derived quantities accurate to ∼1% at σ 0 = 112 degree. The first order expressions are convenient design tools. They lend themselves to variable energy problems and have been applied to the design, construction, and testing of ESQ accelerators at LBL

  13. Why transmission is still the critical link

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, V. [ESBI Alberta Ltd., Calgary, AB (Canada)

    2002-07-01

    This paper describes the important role that transmission plays in the competitive electric power industry in North America and around the world. In the past several years the transmission sector has experienced a lack of investment, congestion on transmission networks, merchant transmission development, and the creation of Regional Transmission Organizations (RTOs). The transmission grid is central to the reliability of the entire electricity system. It also plays a vital role in promoting efficient markets in electricity. The author discusses the consequences of inadequate investment to this critical link within the power industry. He also discusses how much investment is needed, and the challenges and solutions to building an infrastructure. The integrated electric system and the electricity industry in Alberta is very different from those in the United Sates, but the issues facing the industry are the same. The challenge is the sharp increase in the number of system access requests by new generators combined with the difficulties in siting new transmission lines. There are 17,000 km of transmission lines in Alberta, at voltages ranging from 69 kV to 500 kV. There are also connections between neighbouring provinces. The transmission lines have a value of C$1.5 billion. Since there have been no major additions to the transmission grid since the mid-1980s, significant investments in the coming years will have a disproportionate impact on the cost of transmission. Two merchant transmission projects have been proposed. The first will enhance transfer of electricity between Alberta and Saskatchewan by 150 MW, and the second is proposed to be a 1,500 MW, 500 kV DC line from the Fort McMurray area to the Pacific Northwest. 5 figs.

  14. A Novel wave-form command shaper for overhead cranes

    Directory of Open Access Journals (Sweden)

    KHALED ALHAZZA

    2013-12-01

    Full Text Available In this work, a novel command shaping control strategy for oscillation reduction of simple harmonic oscillators is proposed, and validated experimentally. A wave-form acceleration command shaper is derived analytically. The performance of the proposed shaper is simulated numerically, and validated experimentally on a scaled model of an overhead crane. Amplitude modulation is used to enhance the shaper performance, which results in a modulated wave-form command shaper. It is determined that the proposed wave-form and modulated wave-form command shaper profiles are capable of eliminating travel and residual oscillations. Furthermore, unlike traditional impulse and step command shapers, the proposed command shaper has piecewise smoother acceleration, velocity, and displacement profiles. Experimental results using continuous and discrete commands are presented. Experiments with discrete commands involved embedding a saturation model-based feedback in the algorithm of the command shaper.

  15. Postural stability is compromised by fatiguing overhead work.

    Science.gov (United States)

    Nussbaum, Maury A

    2003-01-01

    In a laboratory setting, 16 participants performed a repetitive overhead tapping task for 3 hours or until self-terminated due to substantial shoulder discomfort. Several measures of postural sway and stability were obtained using a force plate, both during quiet standing and during performance of the tapping task. Sway area and peak sway velocity showed consistent increases with time, whereas changes in average velocity and peak whole-body center-of-mass acceleration were either small or nonsignificant. Although relatively insensitive to several task variables, changes in sway areas and peak velocities were substantially larger in trials terminated by the participants. It is argued that fatigue plays a more important role than simple task duration in causing the observed increases in sway, and hence decreases in postural stability. Potential whole-body consequences of localized musculoskeletal stresses appear supported by the results, and implications for safety, risks of falls, and work scheduling are discussed.

  16. Wireless data transmission from inside electromagnetic fields.

    Science.gov (United States)

    Huertas, José Ignacio; Barraza, Roberto; Echeverry, Julian Mauricio

    2010-01-01

    This paper describes analytical and experimental work developed to evaluate the effects of the electromagnetic fields produced by high-voltage lines (400 kV) on wireless data transmission at the 900MHz band. In this work the source of the data transmission is located inside the electromagnetic field and the reception station is located at different distances from the power lines. Different atmospheric conditions are considered.

  17. TRUSSPOLE - Trussed Metallic Pole. Results of its application in 69 kV TL - simple circuit; Trusspole: poste metalico trelicado. Resultados da aplicacao em LT 69kV - circuito simples

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo Ricardo Ralo Liberato da; Mello, Reynaldo Castriota de; Ferreira, Sirio Jose; Cadete, Marcia Augusta de Moura [MJMS - Mendes Junior Montagens e Servicos Ltda., Santa Luzia, MG (Brazil); Souza, Mauro Dias de [EGEL - Engenharia e Construcoes Ltda. (Brazil); Dantas, Roberto Pires [PLT - Projetos de Linhas de Transmissao Ltda. (Brazil)

    1995-12-31

    This report describes the origin, the development and the results of the TRUSSPOLE(Trussed Metallic Post) application in electric power transmission systems. It concerns a spatial trussed structure with a single metallic basis, similar to the concrete or wood pole, able to associate the technical and economical advantages of the trussed structures and the tubular or solid thick poles. The results obtained in the project, in load experiments of a study initial prototype and in the construction of a 69 kV Cs transmission line, with a 53.2 Km extension, using this type of structural solution, are shown 5 refs., 4 figs., 3 tabs.

  18. Differential expression of the Kv1 voltage-gated potassium channel family in the rat nephron.

    Science.gov (United States)

    Carrisoza-Gaytán, Rolando; Salvador, Carolina; Diaz-Bello, Beatriz; Escobar, Laura I

    2014-10-01

    Several potassium (K(+)) channels contribute to maintaining the resting membrane potential of renal epithelial cells. Apart from buffering the cell membrane potential and cell volume, K(+) channels allow sodium reabsorption in the proximal tubule (PT), K(+) recycling and K(+) reabsorption in the thick ascending limb (TAL) and K(+) secretion and K(+) reabsorption in the distal convoluted tubule (DCT), connecting tubule (CNT) and collecting duct. Previously, we identified Kv.1.1, Kv1.3 and Kv1.6 channels in collecting ducts of the rat inner medulla. We also detected intracellular Kv1.3 channel in the acid secretory intercalated cells, which is trafficked to the apical membrane in response to dietary K(+) to function as a secretory K(+) channel. In this work we sought to characterize the expression of all members of the Kv1 family in the rat nephron. mRNA and protein expression were detected for all Kv1 channels. Immunoblots identified differential expression of each Kv1 in the cortex, outer and inner medulla. Immunofluorescence labeling detected Kv1.5 in Bowman´s capsule and endothelial cells and Kv1.7 in podocytes, endothelial cells and macula densa in glomeruli; Kv1.4, Kv1.5 and Kv1.7 in PT; Kv1.2, Kv1.4 and Kv1.6 in TAL; Kv1.1, Kv1.4 and Kv1.6 in DCT and CNT and Kv1.3 in DCT, and all the Kv1 family in the cortical and medullary collecting ducts. Recently, some hereditary renal syndromes have been attributed to mutations in K(+) channels. Our results expand the repertoire of K(+) channels that contribute to K(+) homeostasis to include the Kv1 family.

  19. Inactivation as a new regulatory mechanism for neuronal Kv7 channels

    DEFF Research Database (Denmark)

    Jensen, Henrik Sindal; Grunnet, Morten; Olesen, Søren-Peter

    2007-01-01

    neuronal channels and are important for controlling excitability. Kv7.1 channels have been considered the only Kv7 channels to undergo inactivation upon depolarization. However, here we demonstrate that inactivation is also an intrinsic property of Kv7.4 and Kv7.5 channels, which inactivate to a larger...

  20. The acrylamide (S)-1 differentially affects Kv7 (KCNQ) potassium channels

    DEFF Research Database (Denmark)

    Bentzen, Bo Hjorth; Schmitt, Nicole; Calloe, Kirstine

    2006-01-01

    The family of Kv7 (KCNQ) potassium channels consists of five members. Kv7.2 and 3 are the primary molecular correlates of the M-current, but also Kv7.4 and Kv7.5 display M-current characteristics. M-channel modulators include blockers (e.g., linopirdine) for cognition enhancement and openers (e.g...

  1. Development of 66 kV/6.9 kV 2 MV A prototype HTS power transformer

    International Nuclear Information System (INIS)

    Bohno, T.; Tomioka, A.; Imaizumi, M.; Sanuki, Y.; Yamamoto, T.; Yasukawa, Y.; Ono, H.; Yagi, Y.; Iwadate, K.

    2005-01-01

    We have developed the technology of the producing a HTS magnet for the power transformer. Three subjects have been mainly studied, high voltage technologies, large current and low AC loss technologies and sub-cooling system technologies to establish the technology of 66 kV/6.9 kV 10 MV A class HTS power transformer. In order to verify the validity of elemental technologies, such as high voltage technologies, large current and low AC loss technologies and sub-cooling system technologies, single-phase 2 MV A class 66 kV/6.9 kV prototype HTS transformer was manufactured and tested. In the load loss (AC loss) measurement, it was obtained that the measured value of 633 W was almost corresponding to the calculated value of 576 W at the rated operation of 2 MV A. Moreover, the breakdown was not found all voltage withstand test. These test results indicate that elemental technologies were established for the development of 66 kV/6.9 kV 10 MV A class HTS power transformer

  2. TNB high tension overhead cables: is their electromagnetic field hazard real?

    International Nuclear Information System (INIS)

    Roha Tukimin; Mohd Yusof Mohd Ali; Mohamad Amirul Nizam

    2005-01-01

    Extremely low frequency electromagnetic fields (ELF, EMF) fall under the category of non-ionising radiation. We live in an electromagnetic environment generated by both natural (earths magnetic field, sunlight) and man-made. One of the man-made sources which produces significant electromagnetic fields (EMF) is the electric power supply system. In modern time, electricity has become an essential part of our lives. Electric power supply system, which includes generation, transmission and distribution of the electricity, produces extremely low frequency electromagnetic fields (ELF EMF) that travel along the overhead cables at 50 cycles per second (50 Hz).They are a form of energy that travels in space as electromagnetic waves. In spite of the fact that ELF EMF are very weak electromagnetic emission, they are believed to be hazardous to human health because of their ability to induce current and to initiate energy deposition in the body, which may eventually lead to increase in body temperature, behavioral changes and perhaps cancer in the long term. Due to their potential of causing such health hazard, several companies have approached and requested MINT to carry out surveys and safety assessments of their land properties, which are located close to the transmission lines. This paper highlights some of the works that had been carried out by MINT based on the requests received. They were performed based on international standard IEEE procedures protocols using properly calibrated portable ELF instruments. The results confirmed that ELF EMF did present at the survey sites but were very much lower than the permissible exposure limit recommended for members of public (1000 m Gauss / 5000 V/m). They were found to vary against measurements locations, which were strongly influenced by vertical and horizontal distances from the cables and by the presence of other objects like building and trees. (Author)

  3. Transmission policy in Alberta and Bill 50

    International Nuclear Information System (INIS)

    Church, J.; Rosehart, W.; MacCormack, J.

    2009-01-01

    Plans developed by the Alberta Electric System Operator (AESO) have determined that Alberta's electrical transmission system needs to be expanded. However, there are complex issues that must be considered in order to assess the nature and extent of the needed expansion. Various new amendments to the system were proposed in the Alberta government's Bill 50, including the construction of new transmission lines; the installation of a double circuit 500 kV alternating current line between Edmonton and the Gibbons-Redwater region; the construction of a new 240 kV substation in southeast Calgary; and the installation of 2 single circuit 500 kV alternating current lines between Edmonton and Fort McMurray. This study provided a review of the institutional framework instituted by the government's transmission policy and compared the costs and benefits of 2 large capacity high voltage DC (HVDC) transmission lines proposed for the Edmonton-Calgary corridor relative to the various other transmission system amendment suggestions. An evaluation of Alberta's proposed regulatory process under Bill 50 was also conducted. Results of the study indicated that the addition of the HVDC lines is an inefficient response to concerns over adequate supply and reliability. 72 refs., 18 tabs.

  4. UHV A.C. transmission: Technology and prospects

    International Nuclear Information System (INIS)

    Cauzillo, B.A.; Manzoni, G.; Nicolini, P.

    1992-04-01

    At the beginning of the 70's, UHV transmission was regarded as imminent in many countries in view of the expected concentration of generating units (possibly of the nuclear type and grouped together in a few large plants, each of several GW), and research projects were therefore launched in the U.S.A., Canada, Italy, Japan, USSR, etc. Nowadays, the expected introduction of UHV transmission seems remote due to the slowdown in electricity growth and to the tendency towards distributed generation. Nevertheless, there are exceptions: the 1,200 kV 2,400 km-long transmission system in operation in Siberia-Kazahkstan-Urals, and the 1,100 kV 200 km double-circuit line under construction in Japan (which will, however, be operated at 500 kV up to the end of the century). In addition, in Italy, the research programme of a 1000 kV project has now been completed and a 1,050 kV pilot plant is under construction in Tuscany, consisting of a short 1,050kV line and a 420/1,050 kV 1,200 MVA substation. The technology of UHV AC transmission has therefore been proved effective and may represent an available option for the power systems of the next century. From the power system planning point-of-view, UHV's favourable characteristics lie in the possibility of transmitting large amount of power, of the order of 5 GW per circuit, with lower costs, reduced losses, and less land occupation than in the case of EHV lines

  5. Effects of overhead power lines on the bird population of the Radenhaeuser Lache area in the Marburg-Biedenkopf district, Hessen; Auswirkungen von Freileitungen auf die Voegel der Radenhaeuser Lache, Landkreis Marburg-Biedenkopf/Hessen

    Energy Technology Data Exchange (ETDEWEB)

    Kliebe, K.

    1997-12-01

    In the Radenhaeuser Lache area in the county of Marburg-Biedenkopf 122 birds belonging to at least 18 species were found dead (85.2%) or injured (14.8%) in the period from 1991 to the end of July 1997. In four cases collisions with the high voltage overhead power lines (OHL) running above the flat expanse of water (42 lines of 110 kV and 380 kV) were actually seen. Collisions with the conductors seem to occur with equal frequency when birds come in to land and when they take off in flocks (particularly ducks and lapwings) whether or not this is owing to some disturbance or other (birds of prey, human beings, helicopters or hot-air balloons). (orig.) [Deutsch] Im Bereich der Radenhaeuser Lache (Kreis Marburg-Biedenkopf) wurden seit 1991 bis Ende Juli 1997 122 Voegel in mindestens 18 Arten tot (85,2%) oder verletzt (14,8%) registriert. Kollissionen mit den das Flachgewaesser ueberspannenden Hochspannungsleitungen (42 Seile mit 110 bzw. 380 kV) wurden in vier Faellen durch Sichtbeobachtungen nachgewiesen. Leitungsanfluege geschehen wohl gleichrangig beim Landeanflug und beim scharenweisen Abflug (vor allem Enten und Kiebitze) ohne oder auf Grund von Stoerungen (jagende Greifvoegel, Menschen, Hubschrauber und Heissluftballons). (orig.)

  6. Major Refit for CERN's 400 kV Substation

    CERN Multimedia

    2001-01-01

    The 400 kV substation on the Prévessin site brings in the electricity that powers CERN's accelerators and the majority of the Laboratory's installations. It was originally built in the 1970s for the SPS, and is one of only five privately owned 400 kV sub-stations in France. Three of the others belong to the national railway company, SNCF, supplying the Paris-Marseilles TGV line, the other is at the Cadarache research centre near mouth of the Rhone. After nearly thirty years of service, CERN's substation has just undergone a complete overhaul. The new main 18 kV switchboard for the SPS pulsed network. The electricity supply for the original Prévessin substation was from the 400 kV EDF network, delivered through three 90 MW transformers at 18 kV to the SPS pulsed network, With the arrival of LEP, two 110 MW transformers were added to supply the new accelerator. Now, as CERN gears up for the LHC, additional pulsed power capacity is needed to supply the transfer lines carrying protons from...

  7. 78 FR 68477 - Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of...

    Science.gov (United States)

    2013-11-14

    ...] Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of... requirements specified in the Standard on Overhead and Gantry Cranes (29 CFR 1910.179). DATES: Comments must be... information (29 U.S.C. 657). The paperwork provisions of the Standard on Overhead and Gantry Cranes specify...

  8. Damping of cable vibrations in overhead lines. Daempfung von Leiterseilschwingungen in Hochspannungs-Freileitungen

    Energy Technology Data Exchange (ETDEWEB)

    Moecks, L

    1981-01-01

    The 'Stockbridge'-type vibration damper is presented and its dynamic characteristics are analytically described. In consideration of standard line data a dynamic model of the overhead line is designed. The vibration impulse by the wind and self-damping of the cable are explained with relations being deduced. The entire mathematical model 'overhead line with and without damper' is finally forming the basis for performing numerous parameter studies, with the importance of the damper characteristics and the damper installation site to the value of the dynamic load of the cable being shown very clearly. The presented technique is also convenient for checking the vibration intensity of overhead lines to be newly planned.

  9. Headgear Accessories Classification Using an Overhead Depth Sensor

    Directory of Open Access Journals (Sweden)

    Carlos A. Luna

    2017-08-01

    Full Text Available In this paper, we address the generation of semantic labels describing the headgear accessories carried out by people in a scene under surveillance, only using depth information obtained from a Time-of-Flight (ToF camera placed in an overhead position. We propose a new method for headgear accessories classification based on the design of a robust processing strategy that includes the estimation of a meaningful feature vector that provides the relevant information about the people’s head and shoulder areas. This paper includes a detailed description of the proposed algorithmic approach, and the results obtained in tests with persons with and without headgear accessories, and with different types of hats and caps. In order to evaluate the proposal, a wide experimental validation has been carried out on a fully labeled database (that has been made available to the scientific community, including a broad variety of people and headgear accessories. For the validation, three different levels of detail have been defined, considering a different number of classes: the first level only includes two classes (hat/cap, and no hat/cap, the second one considers three classes (hat, cap and no hat/cap, and the last one includes the full class set with the five classes (no hat/cap, cap, small size hat, medium size hat, and large size hat. The achieved performance is satisfactory in every case: the average classification rates for the first level reaches 95.25%, for the second one is 92.34%, and for the full class set equals 84.60%. In addition, the online stage processing time is 5.75 ms per frame in a standard PC, thus allowing for real-time operation.

  10. 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph.

    Science.gov (United States)

    Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J

    2018-05-01

    We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration

  11. Skeletal muscle Kv7 (KCNQ) channels in myoblast differentiation and proliferation

    International Nuclear Information System (INIS)

    Roura-Ferrer, Meritxell; Sole, Laura; Martinez-Marmol, Ramon; Villalonga, Nuria; Felipe, Antonio

    2008-01-01

    Voltage-dependent K + channels (Kv) are involved in myocyte proliferation and differentiation by triggering changes in membrane potential and regulating cell volume. Since Kv7 channels may participate in these events, the purpose of this study was to investigate whether skeletal muscle Kv7.1 and Kv7.5 were involved during proliferation and myogenesis. Here we report that, while myotube formation did not regulate Kv7 channels, Kv7.5 was up-regulated during cell cycle progression. Although, Kv7.1 mRNA also increased during the G 1 -phase, pharmacological evidence mainly involves Kv7.5 in myoblast growth. Our results indicate that the cell cycle-dependent expression of Kv7.5 is involved in skeletal muscle cell proliferation

  12. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  13. Assessment of Lightning Shielding Performance of a 400 kV Double-Circuit Fully Composite Pylon

    DEFF Research Database (Denmark)

    Jahangirl, Tohid; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    of diagonal and differs from other widely used configurations in overhead transmission lines i.e. horizontal, delta and vertical configurations. On the other hand, unlike traditional steel lattice towers, the pylon removes access to ground potential due to its non-conductive materials and therefore......, the lightning shielding of pylon requires a ground potential access to shield wires which can be achieved by utilizing ground cable inside the hollow cross-arm and pylon body. However, efficient assigning of lightning shielding system for the fully composite pylon is one of the major challenges...

  14. Compact 250-kV injector system for PIGMI

    International Nuclear Information System (INIS)

    Hamm, R.W.; Stevens, R.R. Jr.; Mueller, D.W.; Lederer, H.M.

    1978-01-01

    A 250-kV proton injector to be used in the development of a linac suitable for medical applications has been constructed. This injector utilizes a spherical Pierce geometry to produce a converging beam. A gas insulated accelerating column is cantilevered on a grounded vacuum system, with a separate high voltage equipment dome connected to a 300-kV Cockcroft-Walton power supply. The injector can be operated locally or remotely, with the remote control accomplished by a microprocessor system linked to a central control minicomputer. This injector has been designed as a low-cost compact system. The design details and the data obtained during initial operation are presented

  15. Defense Outsourcing: Better Data Needed to Support Overhead Rates for A-76 Studies

    National Research Council Canada - National Science Library

    1998-01-01

    .... Specifically, this report addresses (1) what is the basis for OMB's new requirement that a standardized 12-percent overhead rate be applied to in-house cost estimates, regardless of the type of commercial activity or where in the country...

  16. Anterior internal impingement of the shoulder in rugby players and other overhead athletes

    Directory of Open Access Journals (Sweden)

    Siddharth R. Shah, MBBS, MSc Sports Medicine (UK, MRCS-Ed

    2017-04-01

    Conclusion: This series of anterior internal impingement, which we believe is the largest in the literature to date, demonstrates the value of an to assess and successfully treat overhead athletes with anterior impingement syndrome.

  17. Optimization of the box-girder of overhead crane with constrained ...

    African Journals Online (AJOL)

    haroun

    Keywords: Overhead crane - Box-girder - New bat algorithm - level of ... much more efficiency and robustness compared to the genetic algorithm (GA) and PSO ...... optimization: developments, applications and resources," in Evolutionary.

  18. A Low-Overhead Cooperative Retransmission Scheme for IR-UWB Networks

    Directory of Open Access Journals (Sweden)

    Ghasem Naddafzadeh Shirazi

    2008-01-01

    Full Text Available The UWB unique properties such as fine ranging and immunity to small scale fading are utilized in order to exploit the multiuser diversity in UWB networks. The optimal cooperation strategies in the absence of control packet overhead are analyzed in the proactive and reactive settings. It is shown that the proposed method achieves a considerable diversity gain while minimizing the overhead of control packet exchange that is required for coordination among the relays.

  19. Alternative approaches to transmission investment

    Energy Technology Data Exchange (ETDEWEB)

    Thon, S. [AltaLink Management Ltd., Calgary, AB (Canada)

    2004-07-01

    AltaLink is Canada's first stand-alone power transmission company, serving all major centres in Alberta and 85 per cent of Alberta's population. It has more than $1 billion in assets, 11,500 km of transmission lines and 300 substations. It was noted that there has not been any significant investment in power transmission in Alberta for the past 20 years, partly because transmission assets have a very long lifespan. The new role of the power grid is to ensure reliability, safety, efficiency, market effectiveness and supply diversity. The benefits and costs of AltaLink's 500 kV North-South upgrade project were outlined. It was noted that a healthy transmission system is the basis for economic growth throughout the province and for the development of Alberta's resource base. The transmission policy in Alberta endorses that all consumers pay postage stamp tariffs. It also promotes a proactive plan for transmission projects, the time to maximum rate (TMR) in limited cases only, a congestion-free grid under normal conditions, the financial commitment of generators, specific time limits on permitting processes, and regional interconnections to benefit all customers. tabs., figs.

  20. Area overhead analysis of SEF: A design methodology for tolerating SEU

    International Nuclear Information System (INIS)

    Blaquiere, Y.; Savaria, Y.

    1987-01-01

    Soft-Error filtering (SEF) is a design methodology proposed recently for implementing machines tolerant to SEU. This paper deals mainly with the evaluation and the reduction of the area overhead brought by SEF. A new shift register filtering latch configuration is proposed. The use of this latch, optimized for minimum area, reduces the area overhead by a factor of 2.6, when compared with latches optimized for time performance. A detailed analysis of the area overhead with SEF implemented on two relatively complex machines produced the following results: a SEF version of the 6800 microprocessor would require an area overhead varying between 12% and 69% depending on the SEF latch used and, a SEF version of the RISCII microprocessor would result in a 38.8% area overhead. An analysis of the cost of implementing the Hamming error correcting code on a register array is presented and this cost is compared with that of implementing SEU tolerance directly with SEF. Finally, a hybrid approach is proposed where a large register array is protected by an error correcting code whereas the isolated latches are replaced by filtering latches. This hybrid approach reduces the area overhead to 18.8% for the RISCII architecture

  1. High power cable with internal water cooling 400 kV

    Science.gov (United States)

    Rasquin, W.; Harjes, B.

    1982-08-01

    Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.

  2. Kingsnorth-London dc transmission link

    Energy Technology Data Exchange (ETDEWEB)

    1966-03-11

    The hvdc transmission link between one of the 500 MW generators at Kingsnorth Power Station and two receiving stations in London will use a three-wire dc cable system rated to carry 1200 A at +- 266 kV. This 51-mile system will be the first dc link in the world to be used as an integral part of a complex interconnected ac network.

  3. Draft Environmental Impact Statement: BPA/Puget Power Northwest Washington Transmission Project

    International Nuclear Information System (INIS)

    1993-11-01

    Bonneville Power Administration (BPS) and Puget Sound Power ampersand Light (Puget Power) propose to upgrade the existing high-voltage transmission system in the Whatcom and Skagit County area between the towns of Custer and Sedro Woolley, including within the city of Bellingham starting in 1995. The upgrades of the interconnected 230,000 volt (230-kV) and 115-kV systems are needed to increase the reliability of the local transmission system and to increase the import capacity on a nearby US-Canada 500-kV intertie by about 850 megawatts (MW). The increase in north-south transfer capability would be shared by BPA and Puget Power (about 425 MW each). Other actions would include replacement of an existing BPA 230-kV single-circuit, wood-pole H-frame transmission line with a lattice-steel double-circuit line; an existing Puget Power 115-kV single wood-pole transmission line rebuild, two short 115-kV Puget Power lines added at BPA's Bellingham Substation; and improvements made at existing BPA and Puget Power substations

  4. KCNE4 is an inhibitory subunit to Kv1.1 and Kv1.3 potassium channels

    DEFF Research Database (Denmark)

    Grunnet, Morten; Rasmussen, Hannne B; Hay-Schmidt, Anders

    2003-01-01

    is detected in the heart and in five different parts of the brain. Having the broad distribution of Kv1 channels in mind, the demonstrated inhibitory property of KCNE4-subunits could locally and/or transiently have a dramatic influence on cellular excitability and on setting resting membrane potentials....

  5. Estimation of flashover voltage probability of overhead line insulators under industrial pollution, based on maximum likelihood method

    International Nuclear Information System (INIS)

    Arab, M.N.; Ayaz, M.

    2004-01-01

    The performance of transmission line insulator is greatly affected by dust, fumes from industrial areas and saline deposit near the coast. Such pollutants in the presence of moisture form a coating on the surface of the insulator, which in turn allows the passage of leakage current. This leakage builds up to a point where flashover develops. The flashover is often followed by permanent failure of insulation resulting in prolong outages. With the increase in system voltage owing to the greater demand of electrical energy over the past few decades, the importance of flashover due to pollution has received special attention. The objective of the present work was to study the performance of overhead line insulators in the presence of contaminants such as induced salts. A detailed review of the literature and the mechanisms of insulator flashover due to the pollution are presented. Experimental investigations on the behavior of overhead line insulators under industrial salt contamination are carried out. A special fog chamber was designed in which the contamination testing of insulators was carried out. Flashover behavior under various degrees of contamination of insulators with the most common industrial fume components such as Nitrate and Sulphate compounds was studied. Substituting the normal distribution parameter in the probability distribution function based on maximum likelihood develops a statistical method. The method gives a high accuracy in the estimation of the 50% flashover voltage, which is then used to evaluate the critical flashover index at various contamination levels. The critical flashover index is a valuable parameter in insulation design for numerous applications. (author)

  6. Superconducting power transmission: the perils and promise

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, E B

    1976-06-01

    The development of bulk electricity transmission systems must be considered in the light of changing growth rates, increasing resistances to ehv overhead transmission and the tendency to concentrate generation in fewer sites. Helium-cooled or superconducting cables possess technical characteristics which will make them suitable as utility network components for power transmission over distances of ten to several hundred miles. These properties are illustrated by considering two applications in existing electrical networks. The first is a 43 mile system to transmit 4800 MVA and the second is a potential application under study in Pennsylvania to transmit 10,000 MVA over a distance of 350 miles or so. Helium-cooled versions of these transmission systems were designed to permit technical and economic evaluations. The major groups and institutions throughout the world engaged in the development of helium-cooled cables are listed and aspects of the technical approaches are briefly described.

  7. High Voltage Power Transmission for Wind Energy

    Science.gov (United States)

    Kim, Young il

    The high wind speeds and wide available area at sea have recently increased the interests on offshore wind farms in the U.S.A. As offshore wind farms become larger and are placed further from the shore, the power transmission to the onshore grid becomes a key feature. Power transmission of the offshore wind farm, in which good wind conditions and a larger installation area than an onshore site are available, requires the use of submarine cable systems. Therefore, an underground power cable system requires unique design and installation challenges not found in the overhead power cable environment. This paper presents analysis about the benefit and drawbacks of three different transmission solutions: HVAC, LCC/VSC HVDC in the grid connecting offshore wind farms and also analyzed the electrical characteristics of underground cables. In particular, loss of HV (High Voltage) subsea power of the transmission cables was evaluated by the Brakelmann's theory, taking into account the distributions of current and temperature.

  8. 35-kV GaAs subnanosecond photoconductive switches

    Energy Technology Data Exchange (ETDEWEB)

    Pocha, M.D.; Druce, R.L. (Lawrence Livermore National Lab., CA (United States))

    1990-12-01

    Photoconductive switches are one of the few devices that allow the generation of high-voltage electrical pulses with subnanosecond rise time. The authors are exploring high-voltage, fast-pulse generation using GaAs photoconductive switches. They have been able to generate 35-kV pulses with rise times as short as 135 ps using 5-mm gap switches and have achieved electric field hold-off of greater than 100 kV/cm. They have also been able to generate an approximately 500-ps FWHM on/off electrical pulse with an amplitude of approximately 3 kV using neutron-irradiated GaAs having short carrier life times. This paper describes the experimental results and discusses fabrication of switches and the diagnostics used to measure these fast signals. They also describe the experience with the nonlinear lock-on and avalanche modes of operation observed in GaAs.

  9. 35-kV GaAs subnanosecond photoconductive switches

    Science.gov (United States)

    Pocha, Michael D.; Druce, Robert L.

    1990-12-01

    High-voltage, fast-pulse generation using GaAs photoconductive switches is investigated. It is possible to to generate 35-kV pulses with risetimes as short as 135 ps using 5-mm gap switches, and electric field hold-off of greater than 100 kV/cm is achieved. An approximately 500-ps FWHM on/off electrical pulse is generated with an amplitude of approximately 3 kV using neutron-irradiated GaAs having short carrier lifetimes. Experimental results are described, and fabrication of switches and the diagnostics used to measure these fast signals are discussed. Experience with the nonlinear lock-on and avalanche modes of operation observed in GaAs is also described.

  10. CIAE 600 kV ns pulse neutron generator

    International Nuclear Information System (INIS)

    Shen Guanren; Guan Xialing; Chen Hongtao

    2001-01-01

    The overall composition of CIAE 600 kV ns Pulse Neutron Generator (CPNG) are introduced, and its characteristic, main technological performance and application were also given. CPNG consists of high voltage power supply with highest output voltage 600 kV, direct current 15 mA, stability and ripple ≤0.1%, 2214 mm x 1604 mm x 1504 mm stainless steel high voltage electrode, built in head equipment uniform field accelerating tube, ns pulsed installation, turbomolecular vacuum pump system and drift pipes at 0 degree and 45 degree. Its characteristics are: (1) high current beam; (2) high current beam ns pulsed installation made use of low energy for chopper and high energy for buncher; (3) compactly laid out and simple in structure

  11. CEBAF 200 kV Inverted Electron Gun

    International Nuclear Information System (INIS)

    Grames, J.M.; Adderley, P.A.; Clark, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.L.; Suleiman, R.; Surles-Law, K.E.L.

    2011-01-01

    Two DC high voltage GaAs photoguns have been built at Jefferson Lab based on a compact inverted insulator design. One photogun provides the polarized electron beam at CEBAF and operates at 130 kV bias voltage. The other gun is used for high average current lifetime studies at a dedicated test facility and has been operated at bias voltage up to 225 kV. The advantages of higher DC voltage for CEBAF include reduced space-charge emittance growth and the potential for prolonged photocathode lifetime. However, a consequence of operating at higher voltages is the increased likelihood of field emission or breakdown, both of which are unacceptable. Highlights of the R and D studies leading toward a production 200keV GaAs photogun for CEBAF will be presented.

  12. A compact 100 kV high voltage glycol capacitor.

    Science.gov (United States)

    Wang, Langning; Liu, Jinliang; Feng, Jiahuai

    2015-01-01

    A high voltage capacitor is described in this paper. The capacitor uses glycerol as energy storage medium, has a large capacitance close to 1 nF, can hold off voltages of up to 100 kV for μs charging time. Allowing for low inductance, the capacitor electrode is designed as coaxial structure, which is different from the common structure of the ceramic capacitor. With a steady capacitance at different frequencies and a high hold-off voltage of up to 100 kV, the glycol capacitor design provides a potential substitute for the ceramic capacitors in pulse-forming network modulator to generate high voltage pulses with a width longer than 100 ns.

  13. Bladder contractility is modulated by Kv7 channels in pig detrusor

    DEFF Research Database (Denmark)

    Svalø, Julie; Bille, Michala; Parameswaran Theepakaran, Neeraja

    2013-01-01

    Kv7 channels are involved in smooth muscle relaxation, and accordingly we believe that they constitute potential targets for the treatment of overactive bladder syndrome. We have therefore used myography to examine the function of Kv7 channels in detrusor, i.e. pig bladder, with a view...... relaxation, suggesting that Kv7.2 and/or Kv7.4 channels constitute the subtypes that are relevant to bladder contractility. The effects of retigabine and ML213 were attenuated by pre-incubation with 10µM XE991 (Kv7.1-7.5 channel blocker) (P...

  14. CONTRIBUTIONS OF INTRACELLULAR IONS TO Kv CHANNEL VOLTAGE SENSOR DYNAMICS.

    Directory of Open Access Journals (Sweden)

    Samuel eGoodchild

    2012-06-01

    Full Text Available Voltage sensing domains of Kv channels control ionic conductance through coupling of the movement of charged residues in the S4 segment to conformational changes at the cytoplasmic region of the pore domain, that allow K+ ions to flow. Conformational transitions within the voltage sensing domain caused by changes in the applied voltage across the membrane field are coupled to the conducting pore region and the gating of ionic conductance. However, several other factors not directly linked to the voltage dependent movement of charged residues within the voltage sensor impact the dynamics of the voltage sensor, such as inactivation, ionic conductance, intracellular ion identity and block of the channel by intracellular ligands. The effect of intracellular ions on voltage sensor dynamics is of importance in the interpretation of gating current measurements and the physiology of pore/voltage sensor coupling. There is a significant amount of variability in the reported kinetics of voltage sensor deactivation kinetics of Kv channels attributed to different mechanisms such as open state stabilization, immobilization and relaxation processes of the voltage sensor. Here we separate these factors and focus on the causal role that intracellular ions can play in allosterically modulating the dynamics of Kv voltage sensor deactivation kinetics. These considerations are of critical importance in understanding the molecular determinants of the complete channel gating cycle from activation to deactivation.

  15. The importance of immunohistochemical analyses in evaluating the phenotype of Kv channel knockout mice.

    Science.gov (United States)

    Menegola, Milena; Clark, Eliana; Trimmer, James S

    2012-06-01

    To gain insights into the phenotype of voltage-gated potassium (Kv)1.1 and Kv4.2 knockout mice, we used immunohistochemistry to analyze the expression of component principal or α subunits and auxiliary subunits of neuronal Kv channels in knockout mouse brains. Genetic ablation of the Kv1.1 α subunit did not result in compensatory changes in the expression levels or subcellular distribution of related ion channel subunits in hippocampal medial perforant path and mossy fiber nerve terminals, where high levels of Kv1.1 are normally expressed. Genetic ablation of the Kv4.2 α subunit did not result in altered neuronal cytoarchitecture of the hippocampus. Although Kv4.2 knockout mice did not exhibit compensatory changes in the expression levels or subcellular distribution of the related Kv4.3 α subunit, we found dramatic decreases in the cellular and subcellular expression of specific Kv channel interacting proteins (KChIPs) that reflected their degree of association and colocalization with Kv4.2 in wild-type mouse and rat brains. These studies highlight the insights that can be gained by performing detailed immunohistochemical analyses of Kv channel knockout mouse brains. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.

  16. Communication overhead on the Intel Paragon, IBM SP2 and Meiko CS-2

    Science.gov (United States)

    Bokhari, Shahid H.

    1995-01-01

    Interprocessor communication overhead is a crucial measure of the power of parallel computing systems-its impact can severely limit the performance of parallel programs. This report presents measurements of communication overhead on three contemporary commercial multicomputer systems: the Intel Paragon, the IBM SP2 and the Meiko CS-2. In each case the time to communicate between processors is presented as a function of message length. The time for global synchronization and memory access is discussed. The performance of these machines in emulating hypercubes and executing random pairwise exchanges is also investigated. It is shown that the interprocessor communication time depends heavily on the specific communication pattern required. These observations contradict the commonly held belief that communication overhead on contemporary machines is independent of the placement of tasks on processors. The information presented in this report permits the evaluation of the efficiency of parallel algorithm implementations against standard baselines.

  17. Vibrational methods of the overhead gas-pipelines technological equipment diagnostics

    International Nuclear Information System (INIS)

    Zakhezin, A.M.; Malysheva, T.V.

    2001-01-01

    The diagnostic methods of overhead gas-pipelines of the technical equipment of gas-compressor station are considered in this article by carrying out registration certification documentation. Some faults of overhead technical gas-pipelines have been proposed. This paper is devoted to the diagnostic methods of the whole gas- pipelines and their parts for some faults during expert checking fulfillment and carrying out registration certification documentation. The analysis of all defects allows to determine a 'between-repairs interval', to develop some operations to avoid these faults and to estimate the repair operation quality, to reduce failure probability. As an example of the effectiveness of technical condition service of vibrational methods by expertise fulfillment have been considered for some defects of the overhead pipelines. (author)

  18. Neuroglial Transmission

    DEFF Research Database (Denmark)

    Gundersen, Vidar; Storm-Mathisen, Jon; Bergersen, Linda Hildegard

    2015-01-01

    as a signaling substance recently shown to act on specific lactate receptors in the brain. Complementing neurotransmission at a synapse, neuroglial transmission often implies diffusion of the transmitter over a longer distance and concurs with the concept of volume transmission. Transmission from glia modulates...... synaptic neurotransmission based on energetic and other local conditions in a volume of tissue surrounding the individual synapse. Neuroglial transmission appears to contribute significantly to brain functions such as memory, as well as to prevalent neuropathologies....

  19. LEVELS OF EXTREMELY LOW-FREQUENCY ELECTRIC AND MAGNETIC FIELDS FROM OVERHEAD POWER LINES IN THE OUTDOOR ENVIRONMENT OF RAMALLAH CITY-PALESTINE.

    Science.gov (United States)

    Abuasbi, Falastine; Lahham, Adnan; Abdel-Raziq, Issam Rashid

    2018-05-01

    In this study, levels of extremely low-frequency electric and magnetic fields originated from overhead power lines were investigated in the outdoor environment in Ramallah city, Palestine. Spot measurements were applied to record fields intensities over 6-min period. The Spectrum Analyzer NF-5035 was used to perform measurements at 1 m above ground level and directly underneath 40 randomly selected power lines distributed fairly within the city. Levels of electric fields varied depending on the line's category (power line, transformer or distributor), a minimum mean electric field of 3.9 V/m was found under a distributor line, and a maximum of 769.4 V/m under a high-voltage power line (66 kV). However, results of electric fields showed a log-normal distribution with the geometric mean and the geometric standard deviation of 35.9 and 2.8 V/m, respectively. Magnetic fields measured at power lines, on contrast, were not log-normally distributed; the minimum and maximum mean magnetic fields under power lines were 0.89 and 3.5 μT, respectively. As a result, none of the measured fields exceeded the ICNIRP's guidelines recommended for general public exposures to extremely low-frequency fields.

  20. Grounding modelling for transient overvoltage simulation in electric power transmission

    International Nuclear Information System (INIS)

    Moreno O, German; Valencia V, Jaime A; Villada, Fernando

    1992-01-01

    Grounding plays an important role in transmission line outages and consequently on electric energy transmission quality indexes. Fundamentals of an accurate modelling for transient behaviour analysis, particularly for the response of transmission lines to lightning, are presented. Also, a method to take into account the electromagnetic propagation guided by the grounding electrodes and finally to assess the grounding impedance in order to simulate the transmission line behaviour under lightning is presented. Analysis of impedance behaviour for diverse configurations and simulation results of over voltages on a real 220 kV line are presented to illustrate the capabilities of the method and of the computational program developed

  1. Nitrate leaching beneath a containerized nursery crop receiving trickle or overhead irrigation.

    Science.gov (United States)

    Colangelo, D J; Brand, M H

    2001-01-01

    Container production of nursery crops is intensive and a potential source of nitrogen release to the environment. This study was conducted to determine if trickle irrigation could be used by container nursery producers as an alternative to standard overhead irrigation to reduce nitrogen release into the environment. The effect of overhead irrigation and trickle irrigation on leachate nitrate N concentration, flow-weighted nitrate N concentration, leachate volume, and plant growth was investigated using containerized rhododendron (Rhododendron catawbiense Michx. 'Album') supplied with a controlled-release fertilizer and grown outdoors on top of soil-monolith lysimeters. Leachate was collected over two growing seasons and overwinter periods, and natural precipitation was allowed as a component of the system. Precipitation accounted for 69% of the water entering the overhead-irrigated system and 80% of the water entering the trickle-irrigated system. Leachate from fertilized plants exceeded the USEPA limit of 10 mg L(-1) at several times and reached a maximum of 26 mg L(-1) with trickle irrigation. Average annual loss of nitrate N in leachate for fertilized treatments was 51.8 and 60.5 kg ha(-1) for the overhead and trickle treatments, respectively. Average annual flow-weighted concentration of nitrate N in leachate of fertilized plants was 7.2 mg L(-1) for overhead irrigation and 12.7 mg L(-1) for trickle irrigation. Trickle irrigation did not reduce the amount of nitrate N leached from nursery containers when compared with overhead irrigation because precipitation nullified the potential benefits of reduced leaching fractions and irrigation inputs provided under trickle irrigation.

  2. Atlas transmission line breakdown analysis

    CERN Document Server

    Nielsen, K E; Ballard, E O; Elizondo, J M; Gribble, R F; McCuistian, B T; Parsons, W M

    1999-01-01

    The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx generators and the central load region. Among the requirements of the transmission lines are low inductance and high reliability. The inter-conductor gap is nominally 2 cm and the lines taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are assembled and inserted as a unit into radial oil-filled steel tanks. The negative, high-voltage, center conductor is 2.54-cm thick and the outer ground conductors are 1.59-cm thick. All 24 triplate transmission lines connect to a transition section at near 1 m radius that couples the transmission lines to a disk/conical solid- dielectric-insulated power flow channel transmission line terminating at the load. Peak operating voltage on the lines can be as high as 240 kV with an effective stress time of 0.8 mu s. Testing of small sections of the ...

  3. 75 FR 56051 - Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project

    Science.gov (United States)

    2010-09-15

    ..., USDA. ACTION: Notice of Availability of Final Environmental Impact Statement. SUMMARY: The Rural.../water/ees/eis.htm , or at the Minnesota Public Utilities Web site at http://energyfacilities.puc.state..., MN 56484; Bovey Public Library, Village Hall, 402 2nd Street, Bovey, MN 55709- 0130; and Coleraine...

  4. improving the transient stability of Nigerian 330kV transmission

    African Journals Online (AJOL)

    eobe

    The overloaded lines which could excite instability in the network are identified. ... stability of the network is analysed by determining the critical clearing time of the acute generators when a ...... economic analysis of stand-alone hybrid energy.

  5. Lightning in hybrid cable-overhead lines and consequent transient overvoltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Schultz Pedersen, Kasper; Bak, Claus Leth

    2017-01-01

    Whereas lines that consist entirely of underground cable are naturally protected from lightning, the phenomenon must be considered for lines that are a mix of overhead lines and underground cables. The difference between overhead lines and underground cables wave impedances may lead to transient ...... conductor and for hits on the earth wire, with and without back flashover. For the most common situation, stroke on the earth wire, it is demonstrated that the cable’s ground propagation mode is dominant, reducing the impact of the reflections....

  6. Annular dark field electron microscope images with better than 2 A resolution at 100 kV

    International Nuclear Information System (INIS)

    Shin, D.H.; Kirkland, E.J.; Silcox, J.

    1989-01-01

    High-resolution scanning transmission electron microscope (STEM) images in the annular dark field (ADF) imaging mode approaching the theoretical point-to-point resolution limit are presented. The ADF images were obtained from a high T c superconducting YBa 2 Cu 3 O 7-x thin-film specimen at 100 kV. The 1.9 A resolution lattice image, which is the smallest lattice spacing in the specimen, corresponds to the minimum resolvable spatial frequency with 5% contrast in the contrast transfer function for annular dark field, and is smaller than the resolution limit given by the Rayleigh criterion. This demonstrates that STEM ADF imaging can have a resolution approximately 40% better than that of the bright field conventional transmission electron microscope (CTEM) imaging at Scherzer condition

  7. Rapid internalization of the oncogenic K+ channel K(V10.1.

    Directory of Open Access Journals (Sweden)

    Tobias Kohl

    Full Text Available K(V10.1 is a mammalian brain voltage-gated potassium channel whose ectopic expression outside of the brain has been proven relevant for tumor biology. Promotion of cancer cell proliferation by K(V10.1 depends largely on ion flow, but some oncogenic properties remain in the absence of ion permeation. Additionally, K(V10.1 surface populations are small compared to large intracellular pools. Control of protein turnover within cells is key to both cellular plasticity and homeostasis, and therefore we set out to analyze how endocytic trafficking participates in controlling K(V10.1 intracellular distribution and life cycle. To follow plasma membrane K(V10.1 selectively, we generated a modified channel of displaying an extracellular affinity tag for surface labeling by α-bungarotoxin. This modification only minimally affected K(V10.1 electrophysiological properties. Using a combination of microscopy and biochemistry techniques, we show that K(V10.1 is constitutively internalized involving at least two distinct pathways of endocytosis and mainly sorted to lysosomes. This occurs at a relatively fast rate. Simultaneously, recycling seems to contribute to maintain basal K(V10.1 surface levels. Brief K(V10.1 surface half-life and rapid lysosomal targeting is a relevant factor to be taken into account for potential drug delivery and targeting strategies directed against K(V10.1 on tumor cells.

  8. Self-actuating grapple automatically engages and releases loads from overhead cranes

    Science.gov (United States)

    Froehlich, J. A.; Karastas, G. A.

    1966-01-01

    Two-piece grapple mechanism consisting of a lift knob secured to the load and a grapple member connected to the crane or lift automatically disengages the load from the overhead lifting device when the load contacts the ground. The key feature is the sliding collar under the lift knob which enables the grapple latch to be stripped off over the lift knob.

  9. Weakly supervised training of deep convolutional neural networks for overhead pedestrian localization in depth fields

    NARCIS (Netherlands)

    Corbetta, A.; Menkovski, V.; Toschi, F.

    Overhead depth map measurements capture sufficient amount of information to enable human experts to track pedestrians accurately. However, fully automating this process using image analysis algorithms can be challenging. Even though hand-crafted image analysis algorithms are successful in many

  10. 49 CFR 214.515 - Overhead covers for existing on-track roadway maintenance machines.

    Science.gov (United States)

    2010-10-01

    ... maintenance machines. 214.515 Section 214.515 Transportation Other Regulations Relating to Transportation... Roadway Maintenance Machines and Hi-Rail Vehicles § 214.515 Overhead covers for existing on-track roadway maintenance machines. (a) For those existing on-track roadway maintenance machines either currently or...

  11. 48 CFR 3452.216-71 - Negotiated overhead rates-fixed.

    Science.gov (United States)

    2010-10-01

    ... acceptability of cost allocation methods shall be determined in accordance with part 31 of the Federal... different period, for which the rates apply, and (4) the specific items treated as direct costs or any changes in the items previously agreed to be direct costs. (e) Pending establishment of fixed overhead...

  12. Design and Application of Cables and Overhead Lines in Wind Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, M. R. [IEEE PES Wind Plant Collector System Design Working Group; Bellei, T.A. [IEEE PES Wind Plant Collector System Design Working Group; Bloethe, W.G. [IEEE PES Wind Plant Collector System Design Working Group; Bradt, M. [IEEE PES Wind Plant Collector System Design Working Group; Brooks, C. [IEEE PES Wind Plant Collector System Design Working Group; Camm, E H [IEEE PES Wind Plant Collector System Design Working Group; Dilling, W. [IEEE PES Wind Plant Collector System Design Working Group; Goltz, B. [IEEE PES Wind Plant Collector System Design Working Group; Hermanson, J. [IEEE PES Wind Plant Collector System Design Working Group; Li, J. [IEEE PES Wind Plant Collector System Design Working Group; Loy, P. [IEEE PES Wind Plant Collector System Design Working Group; McLean, K. [IEEE PES Wind Plant Collector System Design Working Group; Niemira, J. [IEEE PES Wind Plant Collector System Design Working Group; Nuckles, K. [IEEE PES Wind Plant Collector System Design Working Group; Patino, J. [IEEE PES Wind Plant Collector System Design Working Group; Reza, M [IEEE PES Wind Plant Collector System Design Working Group; Richardson, B. [IEEE PES Wind Plant Collector System Design Working Group; Samaan, N. [IEEE PES Wind Plant Collector System Design Working Group; Schoene, Jens [IEEE PES Wind Plant Collector System Design Working Group; Smith, Travis M [ORNL; Snyder, Isabelle B [ORNL; Starke, Michael R [ORNL; Tesch, M. [IEEE PES Wind Plant Collector System Design Working Group; Walling, R. [IEEE PES Wind Plant Collector System Design Working Group; Zahalka, G. [IEEE PES Wind Plant Collector System Design Working Group

    2010-01-01

    This paper presents a summary of the most impor- tant considerations for wind power plant collection system un- derground and overhead cable designs. Various considerations, including conductor selection, soil thermal properties, installa- tion methods, splicing, concentric grounding, and NESC/NEC requirements are discussed.

  13. Optimization of the box-girder of overhead crane with constrained ...

    African Journals Online (AJOL)

    Keywords: Overhead crane - Box-girder - New bat algorithm - level of comparison - Higher strength steel. Optimisation de poutre caisson de pont roulant avec un nouvel algorithme de chauve souris sous contrainte. Une conception optimale pour un poids minimal de la poutre principale d'un pont roulant peut réduire ...

  14. Competitive pricing in markets with different overhead costs : Concealment or leakage of cost information?

    NARCIS (Netherlands)

    Cardinaels, E.; Roodhooft, F.; Warlop, L.; Van Herck, G.

    2008-01-01

    This paper experimentally investigates how leaders and followers in a duopoly set prices for two product markets that have different overhead costs. In a fully crossed two‐by‐two design, we manipulate the participants' private cost report quality as either low or high, representing the extent to

  15. Marangoni Flowers and the Evil Eye: Overhead Presentations of Marangoni Flow

    Science.gov (United States)

    Mundell, Donald W.

    2009-01-01

    Intermolecular forces and surface tension gradients in solutions lead to remarkable flows, known as Marangoni flows, where liquid flows from a region of low surface tension towards higher surface tension. Details of these flows, not visible to the naked eye, are made visible on an overhead projector owing to variation in the index of refraction.…

  16. 30 CFR 77.203 - Use of material or equipment overhead; safeguards.

    Science.gov (United States)

    2010-07-01

    ...; safeguards. 77.203 Section 77.203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS...; safeguards. Where overhead repairs are being made at surface installations and equipment or material is taken...

  17. The transient outward current in mice lacking the potassium channel gene Kv1.4

    Science.gov (United States)

    London, Barry; Wang, Dao W; Hill, Joseph A; Bennett, Paul B

    1998-01-01

    The transient outward current (Ito) plays a prominent role in the repolarization phase of the cardiac action potential. Several K+ channel genes, including Kv1.4, are expressed in the heart, produce rapidly inactivating currents when heterologously expressed, and may be the molecular basis of Ito.We engineered mice homozygous for a targeted disruption of the K+ channel gene Kv1.4 and compared Ito in wild-type (Kv1.4+/+), heterozygous (Kv1.4+/-) and homozygous ‘knockout’ (Kv1.4−/−) mice. Kv1.4 RNA was truncated in Kv1.4−/− mice and protein expression was absent.Adult myocytes isolated from Kv1.4+/+, Kv1.4+/− and Kv1.4−/− mice had large rapidly inactivating outward currents. The peak current densities at 60 mV (normalized by cellular capacitance, in pA pF−1; means ± s.e.m.) were 53.8 ± 5.3, 45.3 ± 2.2 and 44.4 ± 2.8 in cells from Kv1.4+/+, Kv1.4+/− and Kv1.4−/− mice, respectively (P mice.The voltage dependence and time course of inactivation were not changed by targeted disruption of Kv1.4. The mean best-fitting V½ (membrane potential at 50 % inactivation) values for myocytes from Kv1.4 +/+, Kv1.4+/− and Kv1.4−/− mice were -53.5 ± 3.7, -51.1 ± 2.6 and -54.2 ± 2.4 mV, respectively. The slope factors (k) were -10.1 ± 1.4, -8.8 ± 1.4 and -9.5 ± 1.2 mV, respectively. The fast time constants for development of inactivation at -30 mV were 27.8 ± 2.2, 26.2 ± 5.1 and 19.6 ± 2.1 ms in Kv1.4+/+, Kv1.4+/− and Kv1.4−/− myocytes, respectively. At +30 mV, they were 35.5 ± 2.6, 30.0 ± 2.1 and 28.7 ± 1.6 ms, respectively. The time constants for the rapid phase of recovery from inactivation at -80 mV were 32.5 ± 8.2, 23.3 ± 1.8 and 39.0 ± 3.7 ms, respectively.Nearly the entire inactivating component as well as more than 60 % of the steady-state outward current was eliminated by 1 mm 4-aminopyridine in Kv1.4+/+, Kv1.4+/− and Kv1.4−/− myocytes.Western blot analysis of heart membrane extracts showed no significant

  18. 75 FR 44288 - Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of...

    Science.gov (United States)

    2010-07-28

    ...] Overhead and Gantry Cranes; Extension of the Office of Management and Budget's (OMB) Approval of... requirements specified in the Standard on Overhead and Gantry Cranes (29 CFR 1910.179). DATES: Comments must be... requirements for: Marking the rated load of cranes; preparing certification records to verify the inspection of...

  19. The Use of Probability Theory as a Basis for Planning and Controlling Overhead Costs in Education and Industry. Final Report.

    Science.gov (United States)

    Vinson, R. B.

    In this report, the author suggests changes in the treatment of overhead costs by hypothesizing that "the effectiveness of standard costing in planning and controlling overhead costs can be increased through the use of probability theory and associated statistical techniques." To test the hypothesis, the author (1) presents an overview of the…

  20. Implementation of Particle Swarm Optimization Method for Voltage Stability Analysis in 150 kV Sub System Grati – Paiton East Java

    Science.gov (United States)

    Kusumaningtyas, A. B.; Hidayat, M. N.; Ronilaya, F.

    2018-04-01

    Based on the data from State Electric Company on 15 January 2013, the undistributed power in the 150 kV sub system Grati-Paiton Region IV, that consist of 26 bus 150 kV and 2 bus generation 500 kV system, was recorded 3.286,00 MW. At the same time, the frequency of the system was down to 49 Hz. This lead to a deficit generation and unstable voltage condition in the system. Fast Voltage Stability Index (FVSI) method is used in this research to analyze the voltage stability of the buses. For buses with unstable voltage condition, reactive power will be injected through capacitor installation. The site where the capacitor will be installed is determined using the Fast Voltage Stability Index (FVSI) method while the size of the capacitor is determined using the Particle Swarm Optimization (PSO) method. The PSO method has been applied in some researches, such as to determine optimal placement and sizing in radial distribution network as well as in transmission network.. In this research, the PSO method is used to find the Qloss of an interconnection transmission system, which in turn, the value of the Qloss is used to determine the capacitance of the capacitor needed by the system.

  1. Simplified Antenna Group Determination of RS Overhead Reduced Massive MIMO for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Byung Moo Lee

    2017-12-01

    Full Text Available Massive multiple-input multiple-output (MIMO systems can be applied to support numerous internet of things (IoT devices using its excessive amount of transmitter (TX antennas. However, one of the big obstacles for the realization of the massive MIMO system is the overhead of reference signal (RS, because the number of RS is proportional to the number of TX antennas and/or related user equipments (UEs. It has been already reported that antenna group-based RS overhead reduction can be very effective to the efficient operation of massive MIMO, but the method of deciding the number of antennas needed in each group is at question. In this paper, we propose a simplified determination scheme of the number of antennas needed in each group for RS overhead reduced massive MIMO to support many IoT devices. Supporting many distributed IoT devices is a framework to configure wireless sensor networks. Our contribution can be divided into two parts. First, we derive simple closed-form approximations of the achievable spectral efficiency (SE by using zero-forcing (ZF and matched filtering (MF precoding for the RS overhead reduced massive MIMO systems with channel estimation error. The closed-form approximations include a channel error factor that can be adjusted according to the method of the channel estimation. Second, based on the closed-form approximation, we present an efficient algorithm determining the number of antennas needed in each group for the group-based RS overhead reduction scheme. The algorithm depends on the exact inverse functions of the derived closed-form approximations of SE. It is verified with theoretical analysis and simulation that the proposed algorithm works well, and thus can be used as an important tool for massive MIMO systems to support many distributed IoT devices.

  2. The role of handouts, note-taking and overhead transparencies in veterinary science lectures.

    Science.gov (United States)

    McLennan, M W; Isaacs, G

    2002-10-01

    To study student and staff views of the role and use of handouts, note-taking and overhead transparencies in veterinary science lectures at the University of Queensland The Nominal Group Technique was used to help develop a questionnaire, which was completed by 351 students (a response rate of 84%) and 35 staff (76%) from the 5 years of the veterinary course. The data were analysed using the SAS statistical computer package. Staff and students held different views as to the frequency with which handouts should be used, their educational value, and whether they should be complete or partial. Fewer students than staff agreed that handouts discourage further reading in a subject. Almost all staff and students saw the central functions of note-taking to be provision of notes for subsequent revision and encoding information given by the lecturer. More students than staff however, considered that note-taking in lectures interferes with understanding. Staff and students held similar views as to the uses of overheads in lectures. Interestingly however, more staff than students agreed that overheads often contain too much information. Both students and staff saw the central role of note-taking as providing a set of good notes for revision. Generally students preferred that this information be provided in the form of partial or complete handouts, while staff preferred students to take notes and to read outside lectures. Surprisingly, more staff than students felt that overhead transparencies often contained too much information. Note-taking, handouts and overhead transparencies need to be linked in a coherent educational strategy to promote effective learning.

  3. Transmission issues

    International Nuclear Information System (INIS)

    Bradford, J.; Wilson, L.; Thon, S.; Millar, N.

    2005-01-01

    This session on transmission issues focused on the role that transmission plays in electricity markets and the importance of getting the market structure right in terms of generation divestiture with buy back contracts, demand side responsive programs, transmission upgrades and long term contracts. The difficulties of distinguishing between market power and scarcity were examined along with some of the complications that ensue if transmission experiences congestion, as exemplified by the August 2003 blackout in eastern North America. The presentations described the best ways to handle transmission issues, and debated whether transmission should be deregulated or follow market forces. Issues of interconnections and reliability of connections were also debated along with the attempt to integrate renewables into the grid. Some presentations identified what new transmission must be built and what must be done to ensure that transmission gets built. The challenges and business opportunities for transmission in Alberta were discussed with reference to plans to invest in new infrastructure, where it is going outside of the province and how it works with other jurisdictions. Manitoba's Conawapa Hydro Project and its 2000 MW tie line to Ontario was also discussed. Some examples of non-optimal use of interconnections in Europe were also discussed in an effort to learn from these mistakes and avoid them in Canada. tabs., figs

  4. Transmission of power at high voltages

    Energy Technology Data Exchange (ETDEWEB)

    Lane, F J

    1963-01-01

    High voltage transmission is considered to be concerned with circuits and systems operating at or above 132 kV. While the general examination is concerned with ac transmission, dc systems are also included. The choice of voltage for a system will usually involve hazardous assessments of the future requirements of industry, commerce and a changing population. Experience suggests that, if the estimated economic difference between two voltages is not significant, there is good reason to choose the higher voltage, as this will make the better provision for unexpected future expansion. Two principal functions served by transmission circuits in a supply system are: (a) the transportation of energy in bulk from the generator to the reception point in the distribution system; and (b) the interconnection and integration of the generating plant and associated loads. These functions are considered and various types of system are discussed in terms of practicability, viability, quality and continuity of supply. Future developments requiring transmission voltages up to 750 kV will raise many problems which are in the main empirical. Examples are given of the type of problem envisaged and it is suggested that these can only be partially solved by theory and model operation.

  5. Optimization Design of an Inductive Energy Harvesting Device for Wireless Power Supply System Overhead High-Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-03-01

    Full Text Available Overhead high voltage power line (HVPL online monitoring equipment is playing an increasingly important role in smart grids, but the power supply is an obstacle to such systems’ stable and safe operation, so in this work a hybrid wireless power supply system, integrated with inductive energy harvesting and wireless power transmitting, is proposed. The energy harvesting device extracts energy from the HVPL and transfers that from the power line to monitoring equipment on transmission towers by transmitting and receiving coils, which are in a magnetically coupled resonant configuration. In this paper, the optimization design of online energy harvesting devices is analyzed emphatically by taking both HVPL insulation distance and wireless power supply efficiency into account. It is found that essential parameters contributing to more extracted energy include large core inner radius, core radial thickness, core height and small core gap within the threshold constraints. In addition, there is an optimal secondary coil turn that can maximize extracted energy when other parameters remain fixed. A simple and flexible control strategy is then introduced to limit power fluctuations caused by current variations. The optimization methods are finally verified experimentally.

  6. An Issue of Boundary Value for Velocity and Training Overhead Using Cooperative MIMO Technique in Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    M. R. Islam

    2011-06-01

    Full Text Available A boundary value of velocity of data gathering node (DGN and a critical value for training overhead beyond which the cooperative communication in wireless sensor network will not be feasible is proposed in this paper. Multiple Input Multiple Outputs (MIMO cooperative communication is taken as an application. The performance in terms of energy efficiency and delay for a combination of two transmitting and two receiving antennas is analyzed. The results show that a set of critical value of velocity and training overhead pair is present for the long haul communication from the sensors to the data gathering node. Later a graphical relation between boundary value of training overhead and velocity is simulated. A mathematical relation between velocity and training overhead is also developed. The effects of several parameters on training overhead and velocity are analyzed.

  7. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  8. Transmission eigenvalues

    Science.gov (United States)

    Cakoni, Fioralba; Haddar, Houssem

    2013-10-01

    In inverse scattering theory, transmission eigenvalues can be seen as the extension of the notion of resonant frequencies for impenetrable objects to the case of penetrable dielectrics. The transmission eigenvalue problem is a relatively late arrival to the spectral theory of partial differential equations. Its first appearance was in 1986 in a paper by Kirsch who was investigating the denseness of far-field patterns for scattering solutions of the Helmholtz equation or, in more modern terminology, the injectivity of the far-field operator [1]. The paper of Kirsch was soon followed by a more systematic study by Colton and Monk in the context of developing the dual space method for solving the inverse scattering problem for acoustic waves in an inhomogeneous medium [2]. In this paper they showed that for a spherically stratified media transmission eigenvalues existed and formed a discrete set. Numerical examples were also given showing that in principle transmission eigenvalues could be determined from the far-field data. This first period of interest in transmission eigenvalues was concluded with papers by Colton et al in 1989 [3] and Rynne and Sleeman in 1991 [4] showing that for an inhomogeneous medium (not necessarily spherically stratified) transmission eigenvalues, if they existed, formed a discrete set. For the next seventeen years transmission eigenvalues were ignored. This was mainly due to the fact that, with the introduction of various sampling methods to determine the shape of an inhomogeneous medium from far-field data, transmission eigenvalues were something to be avoided and hence the fact that transmission eigenvalues formed at most a discrete set was deemed to be sufficient. In addition, questions related to the existence of transmission eigenvalues or the structure of associated eigenvectors were recognized as being particularly difficult due to the nonlinearity of the eigenvalue problem and the special structure of the associated transmission

  9. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ming, W.Q.; Chen, J.H., E-mail: jhchen123@hnu.edu.cn

    2013-11-15

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations.

  10. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    International Nuclear Information System (INIS)

    Ming, W.Q.; Chen, J.H.

    2013-01-01

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations

  11. The C-terminal HRET sequence of Kv1.3 regulates gating rather than targeting of Kv1.3 to the plasma membrane.

    Science.gov (United States)

    Voros, Orsolya; Szilagyi, Orsolya; Balajthy, András; Somodi, Sándor; Panyi, Gyorgy; Hajdu, Péter

    2018-04-12

    Kv1.3 channels are expressed in several cell types including immune cells, such as T lymphocytes. The targeting of Kv1.3 to the plasma membrane is essential for T cell clonal expansion and assumed to be guided by the C-terminus of the channel. Using two point mutants of Kv1.3 with remarkably different features compared to the wild-type Kv1.3 (A413V and H399K having fast inactivation kinetics and tetraethylammonium-insensitivity, respectively) we showed that both Kv1.3 channel variants target to the membrane when the C-terminus was truncated right after the conserved HRET sequence and produce currents identical to those with a full-length C-terminus. The truncation before the HRET sequence (NOHRET channels) resulted in reduced membrane-targeting but non-functional phenotypes. NOHRET channels did not display gating currents, and coexpression with wild-type Kv1.3 did not rescue the NOHRET-A413V phenotype, no heteromeric current was observed. Interestingly, mutants of wild-type Kv1.3 lacking HRET(E) (deletion) or substituted with five alanines for the HRET(E) motif expressed current indistinguishable from the wild-type. These results demonstrate that the C-terminal region of Kv1.3 immediately proximal to the S6 helix is required for the activation gating and conduction, whereas the presence of the distal region of the C-terminus is not exclusively required for trafficking of Kv1.3 to the plasma membrane.

  12. A continuous acceleration tube of ions under 200 KV

    International Nuclear Information System (INIS)

    Mongodin, G.

    1954-01-01

    The realization of an Van de Graaff accelerator required, for the preliminary studies, the construction of a small proton accelerator, functioning at 200 kV in order to resolve some parasitic effects inherent to the accelerators tubes. The aim of this report is to describe the different organs of the accelerator tube, to explain the operating system and to encode their characteristics. The report first presents the ion source and the beam buncher permitting to inject in the accelerator tube particles of about 9 kV and very batched in a thin beam of circular section. Then the study explain the tube characteristics considered like optic system. A method to obtain precise calculation of particle trajectories is exposed. Aberrations of the system were discussed and balance of the currents on all electrodes inside the tube for different regimes of working were provided. The influence of the residual pressure in the tube were explained. The report finally ends on a part of the fundamental problem of the straining occurring inside the tubes accelerators under high tension. (M.B.) [fr

  13. Expression and function of K(V)2-containing channels in human urinary bladder smooth muscle.

    Science.gov (United States)

    Hristov, Kiril L; Chen, Muyan; Afeli, Serge A Y; Cheng, Qiuping; Rovner, Eric S; Petkov, Georgi V

    2012-06-01

    The functional role of the voltage-gated K(+) (K(V)) channels in human detrusor smooth muscle (DSM) is largely unexplored. Here, we provide molecular, electrophysiological, and functional evidence for the expression of K(V)2.1, K(V)2.2, and the electrically silent K(V)9.3 subunits in human DSM. Stromatoxin-1 (ScTx1), a selective inhibitor of K(V)2.1, K(V)2.2, and K(V)4.2 homotetrameric channels and of K(V)2.1/9.3 heterotetrameric channels, was used to examine the role of these channels in human DSM function. Human DSM tissues were obtained during open bladder surgeries from patients without a history of overactive bladder. Freshly isolated human DSM cells were studied using RT-PCR, immunocytochemistry, live-cell Ca(2+) imaging, and the perforated whole cell patch-clamp technique. Isometric DSM tension recordings of human DSM isolated strips were conducted using tissue baths. RT-PCR experiments showed mRNA expression of K(V)2.1, K(V)2.2, and K(V)9.3 (but not K(V)4.2) channel subunits in human isolated DSM cells. K(V)2.1 and K(V)2.2 protein expression was confirmed by Western blot analysis and immunocytochemistry. Perforated whole cell patch-clamp experiments revealed that ScTx1 (100 nM) inhibited the amplitude of the voltage step-induced K(V) current in freshly isolated human DSM cells. ScTx1 (100 nM) significantly increased the intracellular Ca(2+) level in DSM cells. In human DSM isolated strips, ScTx1 (100 nM) increased the spontaneous phasic contraction amplitude and muscle force, and enhanced the amplitude of the electrical field stimulation-induced contractions within the range of 3.5-30 Hz stimulation frequencies. These findings reveal that ScTx1-sensitive K(V)2-containing channels are key regulators of human DSM excitability and contractility and may represent new targets for pharmacological or genetic intervention for bladder dysfunction.

  14. Contribution of kv7.4/kv7.5 heteromers to intrinsic and calcitonin gene-related Peptide-induced cerebral reactivity

    DEFF Research Database (Denmark)

    Chadha, Preet S; Jepps, Thomas A; Carr, Georgina

    2014-01-01

    Middle cerebral artery (MCA) diameter is regulated by inherent myogenic activity and the effect of potent vasodilators such as calcitonin gene-related peptide (CGRP). Previous studies showed that MCAs express KCNQ1, 4, and 5 potassium channel genes, and the expression products (Kv7 channels) part......) participate in the myogenic control of MCA diameter. The present study investigated the contribution of Kv7.4 and Kv7.5 isoforms to myogenic and CGRP regulation of MCA diameter and determined whether they were affected in hypertensive animals....

  15. High power thyristors with 5 kV blocking voltage. Volume 1: Development of high-voltage-thyristors (4.5 kV) with good dynamic properties

    Science.gov (United States)

    Lock, K.; Patalong, H.; Platzoeder, K.

    1979-01-01

    Using neutron irradiated silicon with considerably lower spread in resistivity as compared to conventionally doped silicon it was possible to produce power thyristors with breakdown voltages between 3.5 kV and 5.5 kV. The thyristor pellets have a diameter of 50 mm. Maximum average on-state currents of 600 to 800 A can be reached with these elements. The dynamic properties of the thryistors could be improved to allow standard applications up to maximum repetitive voltages of 4.5 kV.

  16. Some problems relating to the transmission of electrical power at very high voltage

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, A

    1965-01-01

    Some of the technical and economic factors which influence the choice of a transmission system, particularly a very high voltage one, are discussed. The stability of transmission overvoltages at mains frequency and their control by means of compensating reactances is described. Overvoltages due to circuit-breaker operation and those of atmospheric origin, and appropriate protective devices, the behaviour of equipment at 750 kV, and problems of testing are included. Finally, the 735 kV network now being installed to carry 5300 MW of hydroelectric power 650 km from the Manicouagan River to Quebec and Montreal is described.

  17. Allocating Overhead Costs in a Navy Working Capital Fund Environment: An Analysis and Comparison of Current Navy Policy and Private Sector Practice

    National Research Council Canada - National Science Library

    Schulte, Steven

    1999-01-01

    .... The objective of this thesis was to evaluate the overhead allocation practices of five private sector organizations for the potential improvement of overhead allocation practices in Navy Working Capital Fund activities...

  18. Quantifying Transmission.

    Science.gov (United States)

    Woolhouse, Mark

    2017-07-01

    Transmissibility is the defining characteristic of infectious diseases. Quantifying transmission matters for understanding infectious disease epidemiology and designing evidence-based disease control programs. Tracing individual transmission events can be achieved by epidemiological investigation coupled with pathogen typing or genome sequencing. Individual infectiousness can be estimated by measuring pathogen loads, but few studies have directly estimated the ability of infected hosts to transmit to uninfected hosts. Individuals' opportunities to transmit infection are dependent on behavioral and other risk factors relevant given the transmission route of the pathogen concerned. Transmission at the population level can be quantified through knowledge of risk factors in the population or phylogeographic analysis of pathogen sequence data. Mathematical model-based approaches require estimation of the per capita transmission rate and basic reproduction number, obtained by fitting models to case data and/or analysis of pathogen sequence data. Heterogeneities in infectiousness, contact behavior, and susceptibility can have substantial effects on the epidemiology of an infectious disease, so estimates of only mean values may be insufficient. For some pathogens, super-shedders (infected individuals who are highly infectious) and super-spreaders (individuals with more opportunities to transmit infection) may be important. Future work on quantifying transmission should involve integrated analyses of multiple data sources.

  19. RObust header compression (ROHC) performance for multimedia transmission over 3G/4G wireless networks

    DEFF Research Database (Denmark)

    Fitzek, Frank; Rein, S.; Seeling, P.

    2005-01-01

    Robust Header Compression (ROHC) has recently been proposed to reduce the large protocol header overhead when transmitting voice and other continuous meadi over IP based control stacks in wireless networks. In this paper we evaluate the real-time transmission of GSM encoded voice and H. 26L encod...

  20. 78 FR 50405 - Amended Application for Presidential Permit; Northern Pass Transmission LLC

    Science.gov (United States)

    2013-08-19

    ... Pass proposes to construct and operate a primarily overhead high-voltage direct current (HVDC) electric transmission line that would originate at an HVDC converter station to be constructed at the Des Cantons Substation in Qu[eacute]bec, Canada, then would be converted from HVDC to alternating current (AC) in...

  1. Vegetation clearance distances to prevent wildland fire caused damage to telecommunication and power transmission infrastructure (2)

    Science.gov (United States)

    B. W. Butler; T. Wallace; J. Hogge

    2015-01-01

    Towers and poles supporting power transmission and telecommunication lines have collapsed due to heating from wildland fires. Such occurrences have led to interruptions in power or communication in large municipal areas with associated social and political implications as well as increased immediate danger to humans. Vegetation clearance standards for overhead...

  2. The pan-Kv7 (KCNQ) Channel Opener Retigabine Inhibits Striatal Excitability by Direct Action on Striatal Neurons In Vivo

    DEFF Research Database (Denmark)

    Hansen, Henrik H; Weikop, Pia; Mikkelsen, Maria D

    2017-01-01

    Central Kv7 (KCNQ) channels are voltage-dependent potassium channels composed of different combinations of four Kv7 subunits, being differently expressed in the brain. Notably, striatal dopaminergic neurotransmission is strongly suppressed by systemic administration of the pan-Kv7 channel opener ...... by acute systemic haloperidol administration in the rat. The relative mRNA levels of Kv7 subunits in the rat striatum were found to be Kv7.2 = Kv7.3 = Kv7.5 > >Kv7.4. These data suggest that intrastriatal Kv7 channels play a direct role in regulating striatal excitability in vivo....

  3. Reduced sensory synaptic excitation impairs motor neuron function via Kv2.1 in spinal muscular atrophy.

    Science.gov (United States)

    Fletcher, Emily V; Simon, Christian M; Pagiazitis, John G; Chalif, Joshua I; Vukojicic, Aleksandra; Drobac, Estelle; Wang, Xiaojian; Mentis, George Z

    2017-07-01

    Behavioral deficits in neurodegenerative diseases are often attributed to the selective dysfunction of vulnerable neurons via cell-autonomous mechanisms. Although vulnerable neurons are embedded in neuronal circuits, the contributions of their synaptic partners to disease process are largely unknown. Here we show that, in a mouse model of spinal muscular atrophy (SMA), a reduction in proprioceptive synaptic drive leads to motor neuron dysfunction and motor behavior impairments. In SMA mice or after the blockade of proprioceptive synaptic transmission, we observed a decrease in the motor neuron firing that could be explained by the reduction in the expression of the potassium channel Kv2.1 at the surface of motor neurons. Chronically increasing neuronal activity pharmacologically in vivo led to a normalization of Kv2.1 expression and an improvement in motor function. Our results demonstrate a key role of excitatory synaptic drive in shaping the function of motor neurons during development and the contribution of its disruption to a neurodegenerative disease.

  4. 400 kV injector compact ECR ion source

    International Nuclear Information System (INIS)

    Constantin, F.; Catana, D.; Macovei, M.; Ivanov, E.

    1997-01-01

    Obtaining multiple ionised ions is a fundamental problem for some applications and research. Multiple ionised ions can be produced from electronic bombardment, when n·τ≥5·10 9 cm -3 · s, where n is the density of electrons (in cm -3 ) and τ is the time of interaction between electrons and ions . The relative speed of electrons and ions determines the equilibrium between the stripping process of the atom's electrons and their capture. An ion source with high ionisation efficiency and large output current is the ECR source (Electron Cyclotron Resonance). Using an ECR source with permanent magnets as ion source for the injector will lead to following advantages: - the possibility to obtain multiple ionised particles; - an increase of ion beam intensities; - the expanding of accelerator activities; - a longer working time, due to magnetron lifetime. The ECR ion source is robust, compact and capable of high intensities of extracted ion current. The large functional domain for the residual gas pressure allows the production of multiple charged ions. The source can be easily integrated in the TRILAC's injection structure. We realised a compact microwave ion source which has an axial magnetic field generated by a permanent magnet of Co-Sm. 1200 G magnetic field is greater than the 875 G magnetic field corresponding to the electron-cyclotron frequency of 2.45 GHz. The microwave generator is a magnetron (2.45 GHz and 200 W in continuos wave). The microwave is fed through a coaxial connector on the top of flange. The test was made on He gas at a pressure between 8· 10 -4 and 5·10 -2 torr. The ion beam current was measured vs. extracted potential from 3 kV to 10 kV and has a dependence according to U 3/2 law. A maximal ion current of 300 μA at 10 kV extraction potential was measured. Dimension of ECR ion source, including Einzel lens are φ=12 cm and h=16 cm. (authors)

  5. A fuzzy-logic antiswing controller for three-dimensional overhead cranes.

    Science.gov (United States)

    Cho, Sung-Kun; Lee, Ho-Hoon

    2002-04-01

    In this paper, a new fuzzy antiswing control scheme is proposed for a three-dimensional overhead crane. The proposed control consists of a position servo control and a fuzzy-logic control. The position servo control is used to control crane position and rope length, and the fuzzy-logic control is used to suppress load swing. The proposed control guarantees not only prompt suppression of load swing but also accurate control of crane position and rope length for simultaneous travel, traverse, and hoisting motions of the crane. Furthermore, the proposed control provides practical gain tuning criteria for easy application. The effectiveness of the proposed control is shown by experiments with a three-dimensional prototype overhead crane.

  6. Comparative study of passive and semi-active energy dissipation devices intended for overhead cranes

    International Nuclear Information System (INIS)

    Guihot, P.; Revaud, D.

    1996-04-01

    This paper deals with the results of a bibliographic survey of energy dissipation devices which could be adapted for overhead cranes. The principle of passive devices using friction, yielding steel systems of viscous and viscoelastic systems are remembered. An active control system, which needs a minimum of external control energy is also presented. The application to overhead cranes which have a strong non linear behaviour under strong seismic motion (sliding between rails and wheels, local yielding and damage) is further discussed. The first results of a numerical study in progress are likewise purposed. The criterion of selection of the devices turn on the performance, the robustness and the reliability. The behaviour in the presence of non linearities, the sensitivity to the variations of the vibratory characteristics, and lastly the sensitivity to the response delay of the active controller are taken into account. (authors). 14 refs., 4 figs

  7. Does overhead irrigation with salt affect growth, yield, and phenolic content of lentil plants?

    Directory of Open Access Journals (Sweden)

    Giannakoula Anastasia

    2012-01-01

    Full Text Available Overhead irrigation of lentil plants with salt (100 mM NaCl did not have any significant impact on plant growth, while chlorophyll content and chlorophyll fluorescence parameter Fv/Fm were affected. Under such poor irrigation water quality, the malondialdehyde content in leaves was increased due to the lipid peroxidation of membranes. In seeds, the total phenolic content (TPC was correlated to their total antioxidant capacity (TAC. High performance liquid chromatography-mass spectrometry (HPLC-MS detection showed that flavonoids (catechin, epicatechin, rutin, p-coumaric acid, quercetin, kaempferol, gallic acid and resveratrol appear to be the compounds with the greatest influence on the TAC values. Catechin is the most abundant phenolic compound in lentil seeds. Overhead irrigation with salt reduced the concentration of almost all phenolic compounds analyzed from lentil seed extracts.

  8. ZoOHPraxiscope, Re-Inventing the Zoopraxiscope with an Overhead Projector

    Directory of Open Access Journals (Sweden)

    Christian Faubel

    2015-11-01

    Full Text Available The ZoOHPraxiscope is a modified overhead projector that can be used to show cinematographic animations. It allows blending and mixing of animated shadow play with cinematographic animation. Similar to the Zoopraxiscope that was developed by the photographer Eadweard Muybridge in the 19th century, the ZoOHPraxiscope combines a rotating picture disc with a Laterna Magica and shutter mechanism. The mechanical shutter of the original device is replaced by a high-power LED that can be turned on and off at the fraction of a second. The overhead projector acts as Laterna Magica. This new device is used as a performance instrument to combine sound, vision, shadow play and animation.

  9. Solid Modeling and Finite Element Analysis of an Overhead Crane Bridge

    Directory of Open Access Journals (Sweden)

    C. Alkin

    2005-01-01

    Full Text Available The design of an overhead crane bridge with a double box girder has been investigated and a case study of a crane with 35 ton capacity and 13 m span length has been conducted. In the initial phase of the case study, conventional design calculations proposed by F. E. M. Rules and DIN standards were performed to verify the stress and deflection levels. The crane design was modeled using both solids and surfaces. Finite element meshes with 4-node tetrahedral and 4-node quadrilateral shell elements were generated from the solid and shell models, respectively. After a comparison of the finite element analyses, the conventional calculations and performance of the existing crane, the analysis with quadratic shell elements was found to give the most realistic results. As a result of this study, a design optimization method for an overhead crane is proposed. 

  10. Further Research on an Anti-Swing Control System for Overhead Cranes

    Directory of Open Access Journals (Sweden)

    B. Spruogis

    2018-02-01

    Full Text Available A method of reducing load oscillations that occur when overhead crane reaches destination position is presented in the article. The use of control drive scheme of crane bridge and trolley that ensures a smooth phase trajectory transition of the load to the optimum trajectory in accordance with Pontryagin's maximum principle is proposed. Mentioned control system changes the magnitude or direction of the traction force at the moment when the load is located above the destination. It is found that the degree of change of the traction force depends on the hoisting rope deviation angle from vertical. This study was conducted in order to provide more accurate and fast handling of loads by overhead crane.

  11. Force transmissibility versus displacement transmissibility

    Science.gov (United States)

    Lage, Y. E.; Neves, M. M.; Maia, N. M. M.; Tcherniak, D.

    2014-10-01

    It is well-known that when a single-degree-of-freedom (sdof) system is excited by a continuous motion of the foundation, the force transmissibility, relating the force transmitted to the foundation to the applied force, equals the displacement transmissibility. Recent developments in the generalization of the transmissibility to multiple-degree-of-freedom (mdof) systems have shown that similar simple and direct relations between both types of transmissibility do not appear naturally from the definitions, as happens in the sdof case. In this paper, the authors present their studies on the conditions under which it is possible to establish a relation between force transmissibility and displacement transmissibility for mdof systems. As far as the authors are aware, such a relation is not currently found in the literature, which is justified by being based on recent developments in the transmissibility concept for mdof systems. Indeed, it does not appear naturally, but the authors observed that the needed link is present when the displacement transmissibility is obtained between the same coordinates where the applied and reaction forces are considered in the force transmissibility case; this implies that the boundary conditions are not exactly the same and instead follow some rules. This work presents a formal derivation of the explicit relation between the force and displacement transmissibilities for mdof systems, and discusses its potential and limitations. The authors show that it is possible to obtain the displacement transmissibility from measured forces, and the force transmissibility from measured displacements, opening new perspectives, for example, in the identification of applied or transmitted forces. With this novel relation, it becomes possible, for example, to estimate the force transmissibility matrix with the structure off its supports, in free boundary conditions, and without measuring the forces. As far as force identification is concerned, this

  12. Data transmission

    National Research Council Canada - National Science Library

    Tugal, Dogan A; Tugal, Osman

    1989-01-01

    This updated second edition provides working answers to today's critical questions about designing and managing all types of data transmission systems and features a new chapter on local area networks (LANs...

  13. Characterization Results for the January 2017 H-Tank Farm 2H Evaporator Overhead Sample

    Energy Technology Data Exchange (ETDEWEB)

    Truong, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nicholson, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-04-11

    This report contains the radioanalytical results of the 2H evaporator overhead sample received at SRNL on January 19, 2017. Specifically, concentrations of 137Cs, 90Sr, and 129I are reported and compared to the corresponding Waste Acceptance Criteria (WAC) limits of the Effluent Treatment Project (ETP) Waste Water Collection Tank (WWCT) (rev. 6). All of the radionuclide concentrations in the sample were found to be in compliance with the ETP WAC limits.

  14. Planning of overhead contact lines and simulation of the pantograph running; Oberleitungsplanung und Simulation des Stromabnehmerlaufes

    Energy Technology Data Exchange (ETDEWEB)

    Hofbauer, Gerhard [ALPINE-ENERGIE Oesterreich GmbH, Linz (Austria); Hofbauer, Werner

    2009-07-01

    Using the software FLTG all planning steps for overhead contact lines can be carried out based on the parameters of the contact line type and the line data. Contact line supports and individual spans are presented graphically. The geometric interaction of pantograph and contact line can be simulated taking into account the pantograph type, its sway and the wind action. Thus, the suitability of a line for the interoperability of the transEuropean rail system can be demonstrated. (orig.)

  15. Technical and economical optimisation of overhead power distribution line lightning protection

    Energy Technology Data Exchange (ETDEWEB)

    Katic, N.A. [Elektrovojvodina Power Distribution Co., Nori Sad (Yugoslavia); Savic, M.S. [University of Belgrade (Yugoslavia). Faculty of Electrical Engineering

    1998-05-01

    The existing methodology for overhead line lightning protection design does not take into account customer and utility costs of line outages. In the paper a new concept of line lightning protection design based on economic optimisation is presented. Different tower types are analysed and for various undelivered energy participation factors optimal line design suggested. In line lightning flashover rate estimation both direct and induced surges are analysed. (author)

  16. Measurements of residual deformations of steel-aluminum conductors in operating overhead lines

    Energy Technology Data Exchange (ETDEWEB)

    Durov, E.V.; Kesel' man, L.M.; Treiger, A.S.

    1982-12-01

    Experience in the operation of overhead power lines using steel-aluminum conductors is presented. Measurements were taken on the residual deformation of the steel-aluminum lines to determine the amount of sag increase and to forecast this increase for the entire period of operation. It is recommended that the work on measuring the residual deformation in the power lines be extended to a broader range of operating conditions such as conductors, spans, and climate conditions.

  17. The short-circuit test results of 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer

    International Nuclear Information System (INIS)

    Tomioka, A.; Otonari, T.; Ogata, T.; Iwakuma, M.; Okamoto, H.; Hayashi, H.; Iijima, Y.; Saito, T.; Gosho, Y.; Tanabe, K.; Izumi, T.; Shiohara, Y.

    2011-01-01

    The 6.9 kV/2.3 kV 400 kVA-class single-phase YBCO model transformer with the YBCO tape with copper tape was manufactured for short-circuit current test. Short-circuit test was performed and the short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. The transformer withstood short-circuit current. We are planning to turn the result into a consideration of a 66 kV/6.9 kV-20 MVA-class three-phase superconducting transformer. We are developing an elemental technology for 66 kV/6.9 kV 20 MVA-class power transformer with YBCO conductors. The protection of short-circuit technology is one of the elemental technologies for HTS transformer. Since short-circuit current is much higher than critical current of YBCO tape, there is a possibility that superconducting characteristics may be damaged during short-circuit period. We made a conductor to compose the YBCO tape with copper tape. We manufactured 6.9 kV/2.3 kV 400 kVA-class YBCO model transformer using this conductor and performed short-circuit current test. The short-circuit current of primary winding was 346 A which was about six times larger than the rated current. The I-V characteristics of the winding did not change before and after the test. We may consider this conductor withstands short-circuit current.

  18. Break-down stage in a 20 kV coaxial gun

    International Nuclear Information System (INIS)

    Feugeas, J.; Massa, M.; VonPamel, O.

    1984-01-01

    The electrical break-down of hydrogen in a coaxial electrode system (similar to Mather-type Plasma Focus) was studied for a wide range of pressures. A squirrel's cage outer electrode (cathode) of 50 mm of diameter was used to allow lateral views of the discharge, with an inner electrode (anode) of 17 mm of diameter and a pyrex sleeve of 25 mm length as insulator located at the breech of the gun. A low inductance plane plate transmission line was discharged (20 kV) through a spark gap switch over the system, with a typical peak current of 22 kA, reached after 80 ns from onset of the discharge. The fine structure of the luminous current sheath was studied by frontal and lateral open shutter photographs and by monitoring the current distribution along and across the electrodes gap. The authors tests determine the relative importance of the resistivity related to particle collision effects (αiota) and of the inductive resistivity (α L-center dot) during the break-down stage (iota=length of break-down path, L=inductance)

  19. Design optimization of the 100 kV HV bushing for ITER-DNB

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Sejal, E-mail: sshah@iter-india.org [ITER-India, Institute for Plasma Research, Gandhinagar 382025, Gujarat (India); Rajesh, S. [ITER-India, Institute for Plasma Research, Gandhinagar 382025, Gujarat (India); Microelectronics and Materials Physics Laboratories, P.O. Box 4500, FIN-90014 University of Oulu (Finland); Srusti, B. [DesignTech Systems Ltd, Banjara Hills, Hyderabad, Andhra Pradesh 500034 (India); Bandyopadhyay, M.; Rotti, C.; Singh, M.J.; Roopesh, G.; Chakraborty, A.K. [ITER-India, Institute for Plasma Research, Gandhinagar 382025, Gujarat (India); Schunke, B.; Hemsworth, R.; Chareyre, J. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul lez Durance (France)

    2011-10-15

    The 100 kV bushing of the Diagnostic Neutral Beam (DNB) injector is a cylindrical feedthrough which forms the interface between the gas insulated transmission line and the torus primary vacuum and provides all necessary services to the beam source. All conventions for safety, voltage holding requirement, vacuum compatibility and the choice of materials have been addressed in the design. Finite Element Analyses (FEAs) for the electrostatic and the structural configuration is carried out to validate the design of the High Voltage Bushing (HVB). Several iterations and optimizations of the stress shields are carried out to meet electrostatic criteria, especially at the triple point (the ceramic, metal and vacuum joint), which is critical for good voltage holding. Structural analyses is carried out to assess the stress distribution in the fiber reinforced plastic insulator, the alumina insulator and the integrated HVB for different load cases like operational orientation (horizontal), normal operation and accidental case. Design is further validated for seismic conditions for Seismic Loading-2 (SL-2).

  20. Design optimization of the 100 kV HV bushing for ITER-DNB

    International Nuclear Information System (INIS)

    Shah, Sejal; Rajesh, S.; Srusti, B.; Bandyopadhyay, M.; Rotti, C.; Singh, M.J.; Roopesh, G.; Chakraborty, A.K.; Schunke, B.; Hemsworth, R.; Chareyre, J.

    2011-01-01

    The 100 kV bushing of the Diagnostic Neutral Beam (DNB) injector is a cylindrical feedthrough which forms the interface between the gas insulated transmission line and the torus primary vacuum and provides all necessary services to the beam source. All conventions for safety, voltage holding requirement, vacuum compatibility and the choice of materials have been addressed in the design. Finite Element Analyses (FEAs) for the electrostatic and the structural configuration is carried out to validate the design of the High Voltage Bushing (HVB). Several iterations and optimizations of the stress shields are carried out to meet electrostatic criteria, especially at the triple point (the ceramic, metal and vacuum joint), which is critical for good voltage holding. Structural analyses is carried out to assess the stress distribution in the fiber reinforced plastic insulator, the alumina insulator and the integrated HVB for different load cases like operational orientation (horizontal), normal operation and accidental case. Design is further validated for seismic conditions for Seismic Loading-2 (SL-2).

  1. Power Transmission from Large Offshore Wind Farms

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Kaas

    1999-01-01

    The major part of the coming wind farms in Denmark will be placed offshore. If the location is near a grid with a high short circuit level the power can be transmitted as AC.If the wind farm is far away from the grid and the grid perhaps has a low short circuit level, the best solution...... for transmitting the power can be by DC. At the moment it is possible to build self-commutating DC/AC-inverters up to about 150 kV. This paper will show a concept to a solution for a wind farm and a transmission system based on synchronous generators or a powerformer® with a rated voltage of 50 kV. The AC power...... will be rectified and boosted to a fixed DC voltage (e.g. 100 kV). The speed of the generator will be variable, depending of the wind but also controlled with the duty-cycle of the booster. In that way all wind turbines can be connected to the same DC bus and the cable to the inverter station connected to the AC...

  2. Joint HVAC transmission EMF environmental study

    Energy Technology Data Exchange (ETDEWEB)

    Stormshak, F.; Thompson, J. (Oregon State Univ., Corvallis, OR (United States))

    1992-05-01

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identify any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.

  3. Compilation time analysis to minimize run-time overhead in preemptive scheduling on multiprocessors

    Science.gov (United States)

    Wauters, Piet; Lauwereins, Rudy; Peperstraete, J.

    1994-10-01

    This paper describes a scheduling method for hard real-time Digital Signal Processing (DSP) applications, implemented on a multi-processor. Due to the very high operating frequencies of DSP applications (typically hundreds of kHz) runtime overhead should be kept as small as possible. Because static scheduling introduces very little run-time overhead it is used as much as possible. Dynamic pre-emption of tasks is allowed if and only if it leads to better performance in spite of the extra run-time overhead. We essentially combine static scheduling with dynamic pre-emption using static priorities. Since we are dealing with hard real-time applications we must be able to guarantee at compile-time that all timing requirements will be satisfied at run-time. We will show that our method performs at least as good as any static scheduling method. It also reduces the total amount of dynamic pre-emptions compared with run time methods like deadline monotonic scheduling.

  4. Uptake and Accumulation of Pharmaceuticals in Lettuce Under Surface and Overhead Irrigations

    Science.gov (United States)

    Bhalsod, G.; Chuang, Y. H.; Jeon, S.; Gui, W.; Li, H.; Guber, A.; Zhang, W.

    2015-12-01

    Pharmaceuticals and personal care products are being widely detected in wastewater and surface waters. As fresh water becomes scarcer, interests in using reclaimed water for crop irrigation is intensified. Since reclaimed waters often carry trace levels of pharmaceuticals, accumulation of pharmaceuticals in food crops could increase the risk of human exposure. This study aims to investigate uptake and accumulations of pharmaceuticals in greenhouse-grown lettuce under contrasting irrigation practices (i.e., overhead and surface irrigations). Lettuce was irrigated with water spiked with 11 commonly used pharmaceuticals (acetaminophen, caffeine, carbamazepine, sulfadiazine, sulfamethoxazole, carbadox, trimethoprim, lincomycin hydrochloride, oxytetracycline hydrochloride, monensin sodium, and tylosin). Weekly sampling of lettuce roots, shoots, and soils were continued for 5 weeks, and the samples were freeze dried, extracted for pharmaceuticals and analyzed by LC-MS/MS. Preliminary results indicate that higher concentrations of pharmaceuticals were found in overhead irrigated lettuce compared to surface irrigated lettuce. For carbamezapine, sulfadiazine, trimethoprim, oxytetracycline, and monensin sodium, their concentrations generally increased in lettuce shoots in the overhead treatment over time. However, acetaminophen was found at higher concentrations in both shoots and roots, indicating that acetaminophen can be easily transported in the plant system. This study provides insight on developing better strategies for using reclaimed water for crop irrigations, while minimizing the potential risks of pharmaceutical contamination of vegetables.

  5. 100 kV reliable accurately-synchronized spark gap

    International Nuclear Information System (INIS)

    Bosamykin, V.S.; Gerasimov, A.I.; Zenkov, D.I.

    1987-01-01

    100 kV three-electrode spark gap filled with 40% SF 6 +60% N 2 mixture under the pressure of ∼ 1 MPa, which has spread Δt ≤ ± 5 ns of operating time delay in the range of 10 4 triggerings and commutation energy of 2.5 kJ, providing electric strength is 100%, is described; at 10 kJ Δt is less than ± 10 ns for 10 3 triggerings. Parallel connection of 16 groups, each consisting of 5 spark gaps with series connection, electric strength being 100%, in the pulse charging unit of Arkadiev-Marx generator being in operation for several years manifested their high efficiency; mutual group spread is ≤ ± 15 ns

  6. Do kV really make everything look grey? A comparative study of 600 kV computed tomography systems; Macht kV wirklich grau? Eine Vergleichsstudie zu 600 kV Computertomografiesystemen

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, Michael; Sauerwein, Christoph; Haemmerle, Volker; Knupe, Gunnar [RayScan Technologies GmbH, Meersburg (Germany)

    2013-07-01

    In the automotive industry there is a manufacture of cast aluminium parts of considerable thickness. Growing importance is being attached to methods of nondestructive testing and full metrological characterisation of these parts. A major contribution to this end has been made by the latest generation of CT systems, whose 600 kV X-ray tubes and line detectors make for excellent image quality. The purpose of the present study was to make an objective assessment of the performance of these CT systems by examining the advantages and drawbacks of each. This included comparisons of various parameters such as tube voltage and exposure time as well as different tube and detector technologies and CT measurement methods.

  7. MFTF 230 kV pulsed power substation

    International Nuclear Information System (INIS)

    Wilson, J.H.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) currently under construction at the Lawrence Livermore Laboratory includes a Sustaining Neutral Beam Power Supply System (SNBPSS) consisting of 24 power-supply sets. The System will operate in long pulses (initially .5 seconds and eventually 30 seconds) at high power (200 MW), which will necessitate a large source of ac power. To meet this requirement, a new 230-kV substation is also being built at LLL. The constraints of cost, equipment protection, short operating lifetime (10 years), and reliability dictated a unique substation design. Its unusual features include provisions for fast fault detection and tripping, a capability for limiting ground fault current, low impedance, and economical design

  8. Faraday Rotator 5 kV Capacitor Bank

    International Nuclear Information System (INIS)

    Fetterman, C.C.

    1975-01-01

    A Faraday rotator 5 kV capacitor bank is a pulsed output power supply used to energize Faraday rotators for optical isolation in the ''LLL kJ Glass Laser System.'' Each supply contains either one, two or three parallel 240 μF storage capacitors depending on the size of the isolator used. Generally, the ''A*''(216 μH) isolator is energized with one capacitor, the ''A''(116 μH) isolator uses two capacitors and the ''B''(87 μH) isolator requires three capacitors. All models of isolators have been tested with four capacitors under maximum voltage and 25 feet of RG-217 cable with no hazardous effects. Except for the number of capacitors in each unit, the supplies are otherwise physically identical

  9. Integration of wind power in Germany's transmission grid by using HVDC links

    Energy Technology Data Exchange (ETDEWEB)

    Wasserrab, Andreas; Fleckenstein, Marco; Balzer, Gerd [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    This paper deals with the challenges for the integration of wind power in Germany's transmission grid. Several options for the expansion of transmission grids are discussed. The consideration focuses on HVDC technologies, which are used for further analyses. The basis of the analysis is the transmission grid of a German transmission system operator, which is implemented in a simulation tool. The model consists of the 110-kV-, 220-kV- and the 380-kV-system. In different scenarios the integration of wind power is analysed by applying HVDC links to connect the northern part of the grid with the load centres in the South. The results of load flow calculations are discussed focusing on transmission line loading and voltage stability. The paper concludes with future prospects of HVDC applications in Germany. (orig.)

  10. Application of distantiometric protections to 500 kV lines with AL 100% series compensation; Aplicacion de protecciones distanciometricas a lineas de 500 kV con compensacion serie AL 100%

    Energy Technology Data Exchange (ETDEWEB)

    Gaudio, Juan Carlos; Pesce, Jose Juan O.; Faure, Carlos Hugo [TRANSENER S.A., Buenos Aires (Argentina)

    2001-07-01

    The TRANSENER S.A. viewing the rising of the transmission capacity of the Northeastern Argentine Generators, assumed the installation costs of compensation by series capacitors. In the middle of the year 2000 was put into service a series capacitor bank on the extremity Recreo of the 500 kV to the Malvinas Argentina of the TRANSENER S.A.. The reactance compensation of the line in about 100% was responsible by the necessity of replacing the existent analogic electronic protection by new numerical distantiometric protections on the El Bracho and Malvinas Argentinas transformer station. This paper presents the imposed conditions for the selected line protection, the prior studies posterior the mentioned selection for validating the application, and the difficulties necessary to the task performing as well.

  11. Optimization of 200 kV electrostatic accelerator

    Directory of Open Access Journals (Sweden)

    M Nazmabadi

    2015-09-01

    Full Text Available Optimizations on 200 kV electrostatic accelerator have been done in order to increasing ion current on target, improving vacuum condition and reduction in x-rays emission, increasing stability of high voltage power supply and reaching much greater achievable voltage value. The accelerator tube has most important effect on beam tracing in the electrostatic accelerators. So precautions most be considered in designing and constructing of this part. In order to finding permissible tolerances in construction and assembling of 200 kV electrostatic accelerator column, first the effects of angle deviation of a part from accelerator axis on beam track in the accelerator tube was simulated with Simion 7.0 computer program. We found that in order to prevent beam lost, the tolerances of balancing and co-centering of each part should be smaller than 0.1 mm. Each part of accelerator tube constructed by tolerances lower than 0.05 mm. Ultrasonic cleaning method used in pre-assembling process of parts. Because of its excellences, in the new tube we used borosilicate glass instead of high density alumina as insulators between the metallic electrodes. After three days of working vacuum pumps the system reached to 8.0×10-7 and after months to 5.0×10-7 ultimate pressure values. Measurements showed that by these considerations the maximum of reachable ion current on target was 1.1 mA which increased 50% compared to old machine, while x-ray emission intensity was increased by 25%. Optimizations of high voltage power supply are now under studies and tests

  12. The voltage-gated potassium channel subunit, Kv1.3, is expressed in epithelia

    DEFF Research Database (Denmark)

    Grunnet, Morten; Rasmussen, Hanne B; Hay-Schmidt, Anders

    2003-01-01

    The Shaker-type voltage-gated potassium channel, Kv1.3, is believed to be restricted in distribution to lymphocytes and neurons. In lymphocytes, this channel has gained intense attention since it has been proven that inhibition of Kv1.3 channels compromise T lymphocyte activation. To investigate...

  13. PKC and AMPK regulation of Kv1.5 potassium channels

    DEFF Research Database (Denmark)

    Andersen, Martin Nybo; Skibsbye, Lasse; Tang, Chuyi

    2015-01-01

    The voltage-gated Kv1.5 potassium channel, conducting the ultra-rapid rectifier K(+) current (IKur), is regulated through several pathways. Here we investigate if Kv1.5 surface expression is controlled by the 2 kinases PKC and AMPK, using Xenopus oocytes, MDCK cells and atrial derived HL-1 cells....

  14. harmonic load modeling: a case study of 33 kv abuja steel mill feeder

    African Journals Online (AJOL)

    HOD

    techniques are adopted. This paper studied the harmonic orders of the 33 kV Abuja Steel Feeder modeled as a ... (ETAP) software package was deployed to perform Discrete Fast Transform (DFT) while the input ... and documented in research and development articles ... network with 33kV Abuja Steel feeder as case study.

  15. Pharmacological dissection of K(v)7.1 channels in systemic and pulmonary arteries

    DEFF Research Database (Denmark)

    Chadha, Preet S; Zunke, Friederike; Davis, Alison J

    2012-01-01

    The aim of this study was to characterize the functional impact of KCNQ1-encoded voltage-dependent potassium channels (K(v)7.1) in the vasculature.......The aim of this study was to characterize the functional impact of KCNQ1-encoded voltage-dependent potassium channels (K(v)7.1) in the vasculature....

  16. Development of a 300-kV Marx generator and its application to drive ...

    Indian Academy of Sciences (India)

    Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, ... anode gap of 7·5 mm, an REB having beam voltage 160 kV and duration 150 ns ... lowest stage has a triggered SG which is closed by a 6 kV pulse obtained with the ...

  17. Kv10.1 potassium channel: from the brain to the tumors.

    Science.gov (United States)

    Cázares-Ordoñez, V; Pardo, L A

    2017-10-01

    The KCNH1 gene encodes the Kv10.1 (Eag1) ion channel, a member of the EAG (ether-à-go-go) family of voltage-gated potassium channels. Recent studies have demonstrated that KCHN1 mutations are implicated in Temple-Baraitser and Zimmermann-Laband syndromes and other forms of developmental deficits that all present with mental retardation and epilepsy, suggesting that Kv10.1 might be important for cognitive development in humans. Although the Kv10.1 channel is mainly expressed in the mammalian brain, its ectopic expression occurs in 70% of human cancers. Cancer cells and tumors expressing Kv10.1 acquire selective advantages that favor cancer progression through molecular mechanisms that involve several cellular pathways, indicating that protein-protein interactions may be important for Kv10.1 influence in cell proliferation and tumorigenesis. Several studies on transcriptional and post-transcriptional regulation of Kv10.1 expression have shown interesting mechanistic insights about Kv10.1 role in oncogenesis, increasing the importance of identifying the cellular factors that regulate Kv10.1 expression in tumors.

  18. KCNE3 is an inhibitory subunit of the Kv4.3 potassium channel

    DEFF Research Database (Denmark)

    Lundby, Alicia; Olesen, Søren-Peter

    2006-01-01

    The mammalian Kv4.3 potassium channel is a fast activating and inactivating K+ channel widely distributed in mammalian tissues. Kv4.3 is the major component of various physiologically important currents ranging from A-type currents in the CNS to the transient outward potassium conductance in the ...

  19. Related problems to new regional interconnections. Functioning analyses of the 500 kv Argentine system for exporting the first 1000 W to Brazil; Problemas relacionados com las nuevas interconexiones regionales. Estudios de funcionamiento del sistema argentino de 5 kV para la exportacion de los primeros 1000 MW a Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Jose Luis; Castro, Marcelo [Servicios de Energia Elactrica y Electromecanica S.R.L., Buenos Aires (Argentina)]. E-mail: joseluisalonso@sieye.com.ar; marcelocastro@sieye.com.ar

    2001-07-01

    This work presents the analyses of static functioning (load flows) and demanded transitory stability by the Technical Procedure number 1(TP1) from CAMMESA, corresponding to the first international interconnection between Argentina and Brazil built by the CTM S.A. company. This new entailing, which started to operate in june 2000, links the Rincon de Santa Maria Transmission Station (TS) to a new TS built in Garibaldi city (Brazilian side) through a 500 kV transmission line with extension of 130 kilometers. In Garibaldi, a converter type back to back composed by two 550 kV modules was installed with 1100 MW of total nominal capacity. The Garibaldi TS is interconnected to the Ita TS, which belongs to the ELETROSUL company, through a line of 525 kV with extension of 386 kilometers. The investigations was accomplished according to the contingencies based on the agreement with CAMMESA and the dynamical model of the 50/60 Hz back to back converter (of last generation) called Capacitor Commutated Converter has been represented for all the situations.

  20. From pan-reactive KV7 channel opener to subtype selective opener/inhibitor by addition of a methyl group.

    Directory of Open Access Journals (Sweden)

    Sigrid Marie Blom

    Full Text Available The voltage-gated potassium channels of the KV7 family (KV7.1-5 play important roles in controlling neuronal excitability and are therefore attractive targets for treatment of CNS disorders linked to hyperexcitability. One of the main challenges in developing KV7 channel active drugs has been to identify compounds capable of discriminating between the neuronally expressed subtypes (KV7.2-5, aiding the identification of the subunit composition of KV7 currents in various tissues, and possessing better therapeutic potential for particular indications. By taking advantage of the structure-activity relationship of acrylamide KV7 channel openers and the effects of these compounds on mutant KV7 channels, we have designed and synthesized a novel KV7 channel modulator with a unique profile. The compound, named SMB-1, is an inhibitor of KV7.2 and an activator of KV7.4. SMB-1 inhibits KV7.2 by reducing the current amplitude and increasing the time constant for the slow component of the activation kinetics. The activation of KV7.4 is seen as an increase in the current amplitude and a slowing of the deactivation kinetics. Experiments studying mutant channels with a compromised binding site for the KV7.2-5 opener retigabine indicate that SMB-1 binds within the same pocket as retigabine for both inhibition of KV7.2 and activation of KV7.4. SMB-1 may serve as a valuable tool for KV7 channel research and may be used as a template for further design of better subtype selective KV7 channel modulators. A compound with this profile could hold novel therapeutic potential such as the treatment of both positive and cognitive symptoms in schizophrenia.

  1. Deletion of the Kv2.1 delayed rectifier potassium channel leads to neuronal and behavioral hyperexcitability

    Science.gov (United States)

    Speca, David J.; Ogata, Genki; Mandikian, Danielle; Bishop, Hannah I.; Wiler, Steve W.; Eum, Kenneth; Wenzel, H. Jürgen; Doisy, Emily T.; Matt, Lucas; Campi, Katharine L.; Golub, Mari S.; Nerbonne, Jeanne M.; Hell, Johannes W.; Trainor, Brian C.; Sack, Jon T.; Schwartzkroin, Philip A.; Trimmer, James S.

    2014-01-01

    The Kv2.1 delayed rectifier potassium channel exhibits high-level expression in both principal and inhibitory neurons throughout the central nervous system, including prominent expression in hippocampal neurons. Studies of in vitro preparations suggest that Kv2.1 is a key yet conditional regulator of intrinsic neuronal excitability, mediated by changes in Kv2.1 expression, localization and function via activity-dependent regulation of Kv2.1 phosphorylation. Here we identify neurological and behavioral deficits in mutant (Kv2.1−/−) mice lacking this channel. Kv2.1−/− mice have grossly normal characteristics. No impairment in vision or motor coordination was apparent, although Kv2.1−/− mice exhibit reduced body weight. The anatomic structure and expression of related Kv channels in the brains of Kv2.1−/− mice appears unchanged. Delayed rectifier potassium current is diminished in hippocampal neurons cultured from Kv2.1−/− animals. Field recordings from hippocampal slices of Kv2.1−/− mice reveal hyperexcitability in response to the convulsant bicuculline, and epileptiform activity in response to stimulation. In Kv2.1−/− mice, long-term potentiation at the Schaffer collateral – CA1 synapse is decreased. Kv2.1−/− mice are strikingly hyperactive, and exhibit defects in spatial learning, failing to improve performance in a Morris Water Maze task. Kv2.1−/− mice are hypersensitive to the effects of the convulsants flurothyl and pilocarpine, consistent with a role for Kv2.1 as a conditional suppressor of neuronal activity. Although not prone to spontaneous seizures, Kv2.1−/− mice exhibit accelerated seizure progression. Together, these findings suggest homeostatic suppression of elevated neuronal activity by Kv2.1 plays a central role in regulating neuronal network function. PMID:24494598

  2. Study on Tower Models for EHV Transmission Line

    Directory of Open Access Journals (Sweden)

    Xu Bao-Qing

    2016-01-01

    Full Text Available Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP, six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back- strike intruding wave is very important.

  3. North Central Transmission Line: Guidelines for the environmental impact statement

    International Nuclear Information System (INIS)

    1992-01-01

    Guidelines that Manitoba Hydro must follow in the preparation of the environmental impact statement on the proposed North Central Transmission Line (TCTL) project are presented. The project consists of a 138 kV transmission line, two 25 kV distribution lines, and related ancillary structures and facilities. The review process must be sensitive to cultural and community needs and must involve those most directly affected, and should be grounded in the impacted northern communities. The review should include a project background, the proposal, a description of the existing natural and socio-economic environment, and must address employment, education and training, impacts on renewable resource harvesting, environmental impacts, social impacts and economic impacts, legal/jurisdictional issues, infrastructure, mitigation and compensation, and environmental monitoring and follow-up. 1 fig., 20 tabs

  4. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    International Nuclear Information System (INIS)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-01-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  5. {sup 14}C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Energy Technology Data Exchange (ETDEWEB)

    Santos Arévalo, Francisco-Javier, E-mail: fj.santos@csic.es; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-15

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  6. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Science.gov (United States)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  7. Do overhead sports increase risk for rotator cuff tears in wheelchair users?

    Science.gov (United States)

    Akbar, Michael; Brunner, Manuela; Ewerbeck, Volker; Wiedenhöfer, Bernd; Grieser, Thomas; Bruckner, Thomas; Loew, Markus; Raiss, Patric

    2015-03-01

    To analyze whether frequent overhead-sports activity increases the risk for rotator cuff disease in patients with spinal cord injuries (SCIs) who are wheelchair dependent. Cross-sectional study, risk analysis. Department of Orthopaedic Surgery, Trauma Surgery and Spinal Cord Injury. Patients (N=296) with SCI requiring the full-time use of a manual wheelchair were recruited for this study. The total population was divided into 2 groups (sports vs no sports), among them 103 patients playing overhead sports on a regular basis (at least 1-2 times/wk) and 193 patients involved in overhead sports less than once a week or in no sports activity at all. The mean age of the sports group was 49.1 years. The mean duration of wheelchair dependence was 26.5 years. The mean age of the no-sports group was 48 years. The mean duration of wheelchair dependence was 25.2 years. Each individual completed a questionnaire designed to identify overhead-sports activity on a regular basis and was asked about shoulder problems. Magnetic resonance imaging scans of both shoulders were performed in each patient and analyzed in a standardized fashion. None. Possible differences in continuous data between patients with and without rotator cuff tear were evaluated. The relative risk of suffering from a rotator cuff tear between patients playing overhead sports and those not playing overhead sports was calculated. One hundred three patients played overhead sports regularly and 193 did not. There was no difference between groups regarding age, sex, level of SCI, and duration of wheelchair dependence. The body mass index was significantly lower in the sports group than in the no-sports group (Psports group and in 36.3% of the patients in the no-sports group (Psports group to develop rotator cuff tears was twice as high as for the no-sports group (95% confidence interval, 1.7-2.6; Psports activities have been identified as an additional risk factor, along with age and duration of wheelchair dependence

  8. Longitudinal Acceleration Tests of Overhead Luggage Bins and Auxiliary Fuel Tank in a Transport Airplane Airframe Section

    National Research Council Canada - National Science Library

    McGuire, Robert

    1999-01-01

    This report contains the description and test results of overhead stowage bin calibrations and longitudinal impact testing of a 10-foot transport airframe section conducted at the Transportation Research Center Inc. (TRC...

  9. Longitudinal Acceleration Test of Overhead Luggage Bins and Auxiliary Fuel Tank in a Transport Airplane Airframe Section, Part 2

    National Research Council Canada - National Science Library

    McGuire, Robert

    2000-01-01

    This report contains the description and test results of overhead stowage bin calibrations and longitudinal impact testing of a 10-foot transport airframe section conducted at the Transportation Research Center Inc. (TRC...

  10. The performance of transmission lines and cables subjected to electromagnetic radiation from a nuclear explosion (NEMP)

    International Nuclear Information System (INIS)

    Aguet, M.; Ianovici, M.; Lin, C.C.; Fornerod, F.

    1980-01-01

    The use of armoured cables for telecommunication and data transmission systems is practically essential to avoid electromagnetic interference. The authors have made a mathematical study of the probable effect of a high altitude nuclear explosion. Using a simplified model, the voltages and currents induced into single and multiple-sheathed, overhead and buried cables subjected to an intense magnetic pulse (50kV/m) from high altitude, are determined by computer. It is found that, contrary to expectations the current intensity in the second case is seven times greater than for the overhead conductor. (F.N.S.)

  11. Fundamental role for the KCNE4 ancillary subunit in Kv7.4 regulation of arterial tone

    DEFF Research Database (Denmark)

    Jepps, Thomas A; Carr, Georgina; Lundegaard, Pia R

    2015-01-01

    tone by Kv7 channels. In HEK cells expressing Kv7.4, co-expression of KCNE4 increased the membrane expression of Kv7.4 and significantly altered Kv7.4 current properties. Quantitative PCR analysis of different rat arteries found that the KCNE4 isoform predominated and proximity ligation experiments...... leads to reduced Kv7.4 membrane abundance, a depolarized membrane potential and an augmented response to vasoconstrictors. KCNE4 is a key regulator of the function and expression of Kv7.4 in vascular smooth muscle. ABSTRACT: The KCNE ancillary subunits (KCNE1-5) significantly alter the expression...... to reduced Kv7.4 membrane abundance, a depolarized membrane potential and an augmented response to vasoconstrictors. The present study is the first to demonstrate an integral role of KCNE4 in regulating the function and expression of Kv7.4 in vascular smooth muscle....

  12. Survey of seismic conditions of drilling and blasting operations near overhead electricity power lines

    Science.gov (United States)

    Korshunov, G. I.; Afanasev, P. I.; Bulbasheva, I. A.

    2017-10-01

    The monitoring and survey results of drilling and blasting operations are specified during the development of Afanasyevsky deposit of cement raw materials for a 110 kV electricity power lines structure. Seismic explosion waves and air shock waves were registered in the course of monitoring. The dependency of peak particle velocities on the scaled distance and explosive weight by the delay time was obtained.

  13. Modeling-independent elucidation of inactivation pathways in recombinant and native A-type Kv channels

    Science.gov (United States)

    Fineberg, Jeffrey D.; Ritter, David M.

    2012-01-01

    A-type voltage-gated K+ (Kv) channels self-regulate their activity by inactivating directly from the open state (open-state inactivation [OSI]) or by inactivating before they open (closed-state inactivation [CSI]). To determine the inactivation pathways, it is often necessary to apply several pulse protocols, pore blockers, single-channel recording, and kinetic modeling. However, intrinsic hurdles may preclude the standardized application of these methods. Here, we implemented a simple method inspired by earlier studies of Na+ channels to analyze macroscopic inactivation and conclusively deduce the pathways of inactivation of recombinant and native A-type Kv channels. We investigated two distinct A-type Kv channels expressed heterologously (Kv3.4 and Kv4.2 with accessory subunits) and their native counterparts in dorsal root ganglion and cerebellar granule neurons. This approach applies two conventional pulse protocols to examine inactivation induced by (a) a simple step (single-pulse inactivation) and (b) a conditioning step (double-pulse inactivation). Consistent with OSI, the rate of Kv3.4 inactivation (i.e., the negative first derivative of double-pulse inactivation) precisely superimposes on the profile of the Kv3.4 current evoked by a single pulse because the channels must open to inactivate. In contrast, the rate of Kv4.2 inactivation is asynchronous, already changing at earlier times relative to the profile of the Kv4.2 current evoked by a single pulse. Thus, Kv4.2 inactivation occurs uncoupled from channel opening, indicating CSI. Furthermore, the inactivation time constant versus voltage relation of Kv3.4 decreases monotonically with depolarization and levels off, whereas that of Kv4.2 exhibits a J-shape profile. We also manipulated the inactivation phenotype by changing the subunit composition and show how CSI and CSI combined with OSI might affect spiking properties in a full computational model of the hippocampal CA1 neuron. This work unambiguously

  14. SU-E-I-23: A General KV Constrained Optimization of CNR for CT Abdominal Imaging

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2015-01-01

    Purpose: While Tube current modulation has been well accepted for CT dose reduction, kV adjusting in clinical settings is still at its early stage. This is mainly due to the limited kV options of most current CT scanners. kV adjusting can potentially reduce radiation dose and optimize image quality. This study is to optimize CT abdomen imaging acquisition based on the assumption of a continuous kV, with the goal to provide the best contrast to noise ratio (CNR). Methods: For a given dose (CTDIvol) level, the CNRs at different kV and pitches were measured with an ACR GAMMEX phantom. The phantom was scanned in a Siemens Sensation 64 scanner and a GE VCT 64 scanner. A constrained mathematical optimization was used to find the kV which led to the highest CNR for the anatomy and pitch setting. Parametric equations were obtained from polynomial fitting of plots of kVs vs CNRs. A suitable constraint region for optimization was chosen. Subsequent optimization yielded a peak CNR at a particular kV for different collimations and pitch setting. Results: The constrained mathematical optimization approach yields kV of 114.83 and 113.46, with CNRs of 1.27 and 1.11 at the pitch of 1.2 and 1.4, respectively, for the Siemens Sensation 64 scanner with the collimation of 32 x 0.625mm. An optimized kV of 134.25 and 1.51 CNR is obtained for a GE VCT 64 slice scanner with a collimation of 32 x 0.625mm and a pitch of 0.969. At 0.516 pitch and 32 x 0.625 mm an optimized kV of 133.75 and a CNR of 1.14 was found for the GE VCT 64 slice scanner. Conclusion: CNR in CT image acquisition can be further optimized with a continuous kV option instead of current discrete or fixed kV settings. A continuous kV option is a key for individualized CT protocols

  15. SU-E-I-23: A General KV Constrained Optimization of CNR for CT Abdominal Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V; Zhang, J [University of Kentucky, Lexington, KY (United States)

    2015-06-15

    Purpose: While Tube current modulation has been well accepted for CT dose reduction, kV adjusting in clinical settings is still at its early stage. This is mainly due to the limited kV options of most current CT scanners. kV adjusting can potentially reduce radiation dose and optimize image quality. This study is to optimize CT abdomen imaging acquisition based on the assumption of a continuous kV, with the goal to provide the best contrast to noise ratio (CNR). Methods: For a given dose (CTDIvol) level, the CNRs at different kV and pitches were measured with an ACR GAMMEX phantom. The phantom was scanned in a Siemens Sensation 64 scanner and a GE VCT 64 scanner. A constrained mathematical optimization was used to find the kV which led to the highest CNR for the anatomy and pitch setting. Parametric equations were obtained from polynomial fitting of plots of kVs vs CNRs. A suitable constraint region for optimization was chosen. Subsequent optimization yielded a peak CNR at a particular kV for different collimations and pitch setting. Results: The constrained mathematical optimization approach yields kV of 114.83 and 113.46, with CNRs of 1.27 and 1.11 at the pitch of 1.2 and 1.4, respectively, for the Siemens Sensation 64 scanner with the collimation of 32 x 0.625mm. An optimized kV of 134.25 and 1.51 CNR is obtained for a GE VCT 64 slice scanner with a collimation of 32 x 0.625mm and a pitch of 0.969. At 0.516 pitch and 32 x 0.625 mm an optimized kV of 133.75 and a CNR of 1.14 was found for the GE VCT 64 slice scanner. Conclusion: CNR in CT image acquisition can be further optimized with a continuous kV option instead of current discrete or fixed kV settings. A continuous kV option is a key for individualized CT protocols.

  16. Experimental Investigation on Propagation Characteristics of PD Radiated UHF Signal in Actual 252 kV GIS

    Directory of Open Access Journals (Sweden)

    Tianhui Li

    2017-07-01

    Full Text Available For partial discharge (PD diagnostics in gas insulated switchgears (GISs based on the ultra-high-frequency (UHF method, it is essential to study the attenuation characteristics of UHF signals so as to improve the application of the UHF technique. Currently, the performance of UHF has not been adequately considered in most experimental research, while the constructive conclusions about the installation and position of UHF sensors are relatively rare. In this research, by using a previously-designed broadband sensor, the output signal is detected and analyzed experimentally in a 252 kV GIS with L-shaped structure and disconnecting switch. Since the relative position of the sensor and the defect is usually fixed by prior research, three circumferential angle positions of the defect in cross section are performed. The results are studied by time, statistics and frequency analyses. This identifies that the discontinuity conductor of DS will lead to a rise of both the peak to peak value (Vpp and the transmission rate of the UHF signal. Then, the frequency analysis indicates that the reason for the distinction of signal amplitude and transmission rate is that the mode components of the PD signal are distinctively affected by the special structure of GIS. Finally, the optimal circumferential angle position of the UHF Sensor is given based on the comparison of transmission rates.

  17. Functional and Molecular Evidence for Kv7 Channel Subtypes in Human Detrusor from Patients with and without Bladder Outflow Obstruction

    DEFF Research Database (Denmark)

    Svalø, Julie; Sheykhzade, Majid; Nordling, Jørgen

    2015-01-01

    The aim of the study was to investigate whether Kv7 channels and their ancillary β-subunits, KCNE, are functionally expressed in the human urinary bladder. Kv7 channels were examined at the molecular level and by functional studies using RT-qPCR and myography, respectively. We found mRNA expressi...... between Kv7 channels and β-adrenoceptors in the human urinary bladder. The performed gene expression analysis combined with the organ bath studies imply that compounds that activate Kv7 channels could be useful for treatment of overactive bladder syndrome.......The aim of the study was to investigate whether Kv7 channels and their ancillary β-subunits, KCNE, are functionally expressed in the human urinary bladder. Kv7 channels were examined at the molecular level and by functional studies using RT-qPCR and myography, respectively. We found mRNA expression...... (activator of Kv7.1 channels, 10 μM) and ML213 (activator of Kv7.2, Kv7.4, Kv7.4/7.5 and Kv7.5 channels, 10 μM), reduced the tone of 1 μM carbachol pre-constricted bladder strips. XE991 (blocker of Kv7.1-7.5 channels, 10 μM) had opposing effects as it increased contractions achieved with 20 mM KPSS...

  18. Thyristors for dc transmission

    Energy Technology Data Exchange (ETDEWEB)

    1966-05-06

    As a first stage towards determining the feasibility of applying thyristors to hvdc converter terminals, the Westinghouse Electric Corporation has built a converter laboratory capable of testing thyristors under conditions similar to those which would have to be met in a 200 kV dc system. The equipment has been designed to test a 5 kV 600 A group of thyrisotrs, elevated 200 kV above earth. This rating has been chosen so that there would be a sufficient number of thyristors in series to enable the gating and voltage division characteristics to be investigated and at the same time the group could be operated at a potential equivalent to a complete 200 kV dc bridge.

  19. KCNE1 constrains the voltage sensor of Kv7.1 K+ channels.

    Directory of Open Access Journals (Sweden)

    Liora Shamgar

    Full Text Available Kv7 potassium channels whose mutations cause cardiovascular and neurological disorders are members of the superfamily of voltage-gated K(+ channels, comprising a central pore enclosed by four voltage-sensing domains (VSDs and sharing a homologous S4 sensor sequence. The Kv7.1 pore-forming subunit can interact with various KCNE auxiliary subunits to form K(+ channels with very different gating behaviors. In an attempt to characterize the nature of the promiscuous gating of Kv7.1 channels, we performed a tryptophan-scanning mutagenesis of the S4 sensor and analyzed the mutation-induced perturbations in gating free energy. Perturbing the gating energetics of Kv7.1 bias most of the mutant channels towards the closed state, while fewer mutations stabilize the open state or the inactivated state. In the absence of auxiliary subunits, mutations of specific S4 residues mimic the gating phenotypes produced by co-assembly of Kv7.1 with either KCNE1 or KCNE3. Many S4 perturbations compromise the ability of KCNE1 to properly regulate Kv7.1 channel gating. The tryptophan-induced packing perturbations and cysteine engineering studies in S4 suggest that KCNE1 lodges at the inter-VSD S4-S1 interface between two adjacent subunits, a strategic location to exert its striking action on Kv7.1 gating functions.

  20. The secret life of ion channels: Kv1.3 potassium channels and proliferation.

    Science.gov (United States)

    Pérez-García, M Teresa; Cidad, Pilar; López-López, José R

    2018-01-01

    Kv1.3 channels are involved in the switch to proliferation of normally quiescent cells, being implicated in the control of cell cycle in many different cell types and in many different ways. They modulate membrane potential controlling K + fluxes, sense changes in potential, and interact with many signaling molecules through their intracellular domains. From a mechanistic point of view, we can describe the role of Kv1.3 channels in proliferation with at least three different models. In the "membrane potential model," membrane hyperpolarization resulting from Kv1.3 activation provides the driving force for Ca 2+ influx required to activate Ca 2+ -dependent transcription. This model explains most of the data obtained from several cells from the immune system. In the "voltage sensor model," Kv1.3 channels serve mainly as sensors that transduce electrical signals into biochemical cascades, independently of their effect on membrane potential. Kv1.3-dependent proliferation of vascular smooth muscle cells (VSMCs) could fit this model. Finally, in the "channelosome balance model," the master switch determining proliferation may be related to the control of the Kv1.3 to Kv1.5 ratio, as described in glial cells and also in VSMCs. Since the three mechanisms cannot function independently, these models are obviously not exclusive. Nevertheless, they could be exploited differentially in different cells and tissues. This large functional flexibility of Kv1.3 channels surely gives a new perspective on their functions beyond their elementary role as ion channels, although a conclusive picture of the mechanisms involved in Kv1.3 signaling to proliferation is yet to be reached.

  1. X irradiation of human epidermis in vitro. 2. Comparison of single 44 kV and 200 kV X irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Wollina, U; Fueller, J; Burger, B; Hipler, C

    1989-01-01

    On the example of the reduction of epidermal adhesion of FITC wheat germ agglutinine (WGA) the direct membrane effect of a single X irradiation (44 kV and 220 kV) was analyzed in vitro. Human normal skin and psoriasis centres were compared. Normal skin showed no alteration of microscopically visible FITC-WGA adhesion on epidermal cells over the whole dose range. Foci of psoriasis responded to doses of /ge/ 5 Gy (44 and 220 kV) with a drastic reduction of epidermal lectin binding to lower and medium cell layers. Maximum efficacy was with 5 Gy (44 kV) or 10 Gy (220 kV). A dose elevation up to 20 Gy did not result in an increase of efficacy. Topographically the radiosensitive FITC-WGA adhesion could chiefly be seen in the dermal ridges. The findings support the impression of an increased radiosensitivity of the lesional psoriatic epidermis compared with normal skin. This is connected with an abnormal differentiation of keratinocytes in psoriasis. (author).

  2. Development and use of 60 kV, and 150 kV floating deck modulators for high voltage protection of multi-megawatt ion beam accelerators

    International Nuclear Information System (INIS)

    Barber, G.C.; Ponte, N.S.; Schilling, G.

    1977-01-01

    Extraction currents of 60 A at 40 kV have been produced by utilizing a 60 kV floating deck modulator interfaced to a high voltage power supply. The modulator is operated in a series mode to repetitively pulse power to the ion beam accelerator. Current monitoring and other protective circuits provide interrupt commands to the series switch tube when faults occur. The constant current characteristics of the water cooled tetrode and the rapid response of the protective circuits effectively limit the fault energy to the ion source. Three of the 60 kV decks have been modified and stacked in a series configuration to supply 150 kV, 50 A pulses. This system supplies power for development of higher-energy multi-grid sources. In this system attention has been focused on forced voltage sharing of the three decks and on protective circuits for fault conditions. All control signal processing and conditioning is performed at ground level. Fiber optic links are used to interface with the high potential associated with the floating decks. A shunt modulator incorporated with this system provides regulation of the voltage to the ion source gradient grid. Future modulator development includes a system to deliver 100 A at 80 kV

  3. Seismic strengthening of overhead roads between reactor buildings of WWER-1000 MW type NPP

    International Nuclear Information System (INIS)

    Stoyanov, G.; Jordanov, M.

    2005-01-01

    This paper presents results obtained during the upgrading design of overhead roads (OHR) between WWER-1000 MW Reactor Units at Kozloduy NPP. In order to avoid the deficiencies of OHR seismic capacity different approaches were developed based on the site and structure specifics. Overhead roads are precasted RC structures. They consist of pedestrian gallery and pipeline RC box, connecting reactor buildings with auxiliary building. They are mounted at approximately 10 m above ground level. The overhead roads are evaluated at their as-is status and a seismic upgrading of the structure is designed. The analysis of the upgraded structure is performed for Review Level Earthquake (RLE). Soil-Structure Interaction (SSI) effects are taken into account through equivalent soil springs with frequency adjusted stiffnesses. The upgraded structure is checked for conformance with the specially developed technical design specification based on International, US and Bulgarian standards and codes, taking into account site specific conditions. The general approach is consistent with up-to-date practice for evaluation and upgrade of nuclear power plant facilities. The existing site conditions and Owner's requirements are taken into account during development of the upgrading. The proposed upgrading measures can be divided in two major categories global and local. Special attention is paid to improvement of the ductile behavior of the structure through new detailing and upgrading of existing connection. These measures are grouped in two final design concepts and after a comparative study one of them is chosen for implementation. For the upgraded structure response spectra are derived at locations where equipment is attached. (authors)

  4. Central uplift of custom immobilization radiotherapy patients with lower limb overhead sagittal laser affected without mobile

    International Nuclear Information System (INIS)

    Velazquez Miranda, S.; Delgado Gil, M. M.; Ortiz Seidel, M.

    2011-01-01

    If you have a laser moving overhead sagittal or the location of tumors in the lower extremities is laborious, as to reference properly in the CT, is necessary before tattooing in the treatment table using their ability to relate the lateral midline with tattoos on the limb. For anatomical forms often happens that lasers are not displayed on the areas of our interest. The problem can be overcome if between the legs raise the bag or custom immobilizer above the height of the patient's abdomen, as this will have a central reference reliable and well designed lasers.

  5. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    . In this paper, we compare a lock-free implementation of a priority queue with a lock-based implementation. We perform experiments with processors of different generations and observe large performance differences for lock-free data structures depending on the processor generation. The lock-free implementation...... performs much better on the most recent processor generation. We investigate this performance trend, using a set of micro-benchmarks and show a significant difference in the overhead of atomic operations between processor generations. The lock-free implementation executes approximately three times as many...

  6. Audio-frequency noise emissions from high-voltage overhead power lines

    International Nuclear Information System (INIS)

    Semmler, M.; Straumann, U.; Roero, C.; Teich, T. H.

    2005-01-01

    This article discusses the noise-emissions caused by high-voltage overhead power lines that can occur under certain atmospheric conditions. These emissions, caused by electric discharges around the conductors, can achieve disturbing values, depending on the conditions prevailing at the time in question. The causes of the discharges are examined and the ionisation processes involved are looked at. The parameters influencing the discharges are discussed and measures that can be taken to reduce such audio-frequency emissions are looked at. The authors note that a reduction of peripheral field strengths can reduce emissions and that hydrophilic coatings can lead to faster reduction of such effects after rainfall

  7. Development of 600 kV triple resonance pulse transformer.

    Science.gov (United States)

    Li, Mingjia; Zhang, Faqiang; Liang, Chuan; Xu, Zhou

    2015-06-01

    In this paper, a triple-resonance pulse transformer based on an air-core transformer is introduced. The voltage across the high-voltage winding of the air-core transformer is significantly less than the output voltage; instead, the full output voltage appears across the tuning inductor. The maximum ratio of peak load voltage to peak transformer voltage is 2.77 in theory. By analyzing pulse transformer's lossless circuit, the analytical expression for the output voltage and the characteristic equation of the triple-resonance circuit are presented. Design method for the triple-resonance pulse transformer (iterated simulation method) is presented, and a triple-resonance pulse transformer is developed based on the existing air-core transformer. The experimental results indicate that the maximum ratio of peak voltage across the load to peak voltage across the high-voltage winding of the air-core transformer is approximately 2.0 and the peak output voltage of the triple-resonance pulse transformer is approximately 600 kV.

  8. Accurate Iterative Analysis of the K-V Equations

    CERN Document Server

    Anderson, Oscar A

    2005-01-01

    Previous solutions of the K-V equations have either yielded poor accuracy or have been complex and difficult to follow. We describe a new approach, simple in concept, easy to use, with accuracy substantially improved over previous treatments. The results are given in the same form as the smooth approximation but include a few correction terms obtained from the field gradient integrated along the axis of a quadrupole cell. The input quantities–quadrupole field, beam current, and emittance–yield the average beam radius, the maximum envelope excursion, and the depressed and undepressed tunes. For all values of the input parameters, the results are much closer to the exact values from simulations than are results from the smooth approximation. For example, with the parameters adjusted for an exact phase advance of 83.4 degrees and 50% tune depression, both tunes are in error by less than 0.5%–over 22 times better than the smooth approximation. The error in maximum radius is 0.04%, impro...

  9. Novel Kv7.1-phosphatidylinositol 4,5-bisphosphate interaction sites uncovered by charge neutralization scanning

    DEFF Research Database (Denmark)

    Eckey, Karina; Wrobel, Eva; Strutz-Seebohm, Nathalie

    2014-01-01

    Kv7.1 to Kv7.5 α-subunits belong to the family of voltage-gated potassium channels (Kv). Assembled with the β-subunit KCNE1, Kv7.1 conducts the slowly activating potassium current IKs, which is one of the major currents underlying repolarization of the cardiac action potential. A known regulator...... of corresponding long QT syndrome mutants suggested impaired PIP2 regulation as the cause for channel dysfunction. To clarify the underlying structural mechanism of PIP2 binding, molecular dynamics simulations of Kv7.1/KCNE1 complexes containing two PIP2 molecules in each subunit at specific sites were performed...

  10. An efficient transmission power control scheme for temperature variation in wireless sensor networks.

    Science.gov (United States)

    Lee, Jungwook; Chung, Kwangsue

    2011-01-01

    Wireless sensor networks collect data from several nodes dispersed at remote sites. Sensor nodes can be installed in harsh environments such as deserts, cities, and indoors, where the link quality changes considerably over time. Particularly, changes in transmission power may be caused by temperature, humidity, and other factors. In order to compensate for link quality changes, existing schemes detect the link quality changes between nodes and control transmission power through a series of feedback processes, but these approaches can cause heavy overhead with the additional control packets needed. In this paper, the change of the link quality according to temperature is examined through empirical experimentation. A new power control scheme combining both temperature-aware link quality compensation and a closed-loop feedback process to adapt to link quality changes is proposed. We prove that the proposed scheme effectively adapts the transmission power to the changing link quality with less control overhead and energy consumption.

  11. An Efficient Transmission Power Control Scheme for Temperature Variation in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jungwook Lee

    2011-03-01

    Full Text Available Wireless sensor networks collect data from several nodes dispersed at remote sites. Sensor nodes can be installed in harsh environments such as deserts, cities, and indoors, where the link quality changes considerably over time. Particularly, changes in transmission power may be caused by temperature, humidity, and other factors. In order to compensate for link quality changes, existing schemes detect the link quality changes between nodes and control transmission power through a series of feedback processes, but these approaches can cause heavy overhead with the additional control packets needed. In this paper, the change of the link quality according to temperature is examined through empirical experimentation. A new power control scheme combining both temperature-aware link quality compensation and a closed-loop feedback process to adapt to link quality changes is proposed. We prove that the proposed scheme effectively adapts the transmission power to the changing link quality with less control overhead and energy consumption.

  12. New transmission interconnection reduces consumer costs

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2008-09-15

    The Central American electric interconnection system (SIEPAC) project will involve the construction of a 1830 km 230 kV transmission system that will link Guatemala, El Salvador, Honduras, Costa Rica, Nicaragua, and Panama. The system is expected to alleviate the region's power shortages and reduce electricity costs for consumers. Costs for the SIEPAC project have been estimated at $370 million. The system will serve approximately 37 million customers, and will include 15 substations. The contract for building the electrical equipment has been awarded to Schweitzer Engineering Laboratories (SEL) who plan to manufacture components at a plant in Mexico. The equipment will include high speed line protection, automation, and control systems. Line current differential systems and satellite-synchronized clocks will also be used. The new transmission system is expected to be fully operational by 2009. 1 fig.

  13. Long-distance power transmission technology. Microwave power transmission; Denryoku no chokyori yuso gijutsu. Micro ha musen soden

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, N [Kobe University, Kobe (Japan). Faculty of Engineering

    1994-11-05

    This paper explains the principles of microwave power transmission as a long-distance power transmission technology, and the status of its development. Under an assumption of using a wave length of 12 cm (2.45 GHz) and a transmission distance of 1 km, an ideal wireless power transmission can realize transmitting the power at an efficiency of 95% or higher if transmitting and receiving antennas with a radius of 8.8 m are used. What remains as important requirements is raising the efficiency of conversion from power supply into microwaves, and the efficiency of rectification after the power has been received. By using microwave energy sent from a transmission antenna installed on the roof of an automobile, a model airplane with a receiving antenna installed at its rear flew successfully for 40 seconds under the microwave lifted airplane experiment (MILAX). In an experiment of transmitting microwave power in space, power was successfully transmitted to the child rocket as an event under the International Space Year - Microwave Energy Transmission in Space (ISY-METS). The microwave wireless power transmission on the ground would have a possibility of taking over the overhead line transmission into islands. An attempt is scheduled to send power of 5 kW by using transmission and receiving antennas with a diameter of 3 m to investigate effects on transmission efficiency, and communications and electromagnetic environments, and to collect basic data. 3 refs., 3 figs.

  14. 800 kW transmission line research at Leatherhead

    Energy Technology Data Exchange (ETDEWEB)

    1964-05-29

    The experimental transmission line was installed at Leatherhead to enable the Central Electricity Research Laboratories to study the insulators, fittings, and conductors likely to be needed for ac power transmission at voltages up to the equivalent of 800 kV three-phase. Continuous recording will be made of corona power loss and radio and television interference. For this purpose C.E.R.L. has developed a statistical radio-interference recorder. The instrumentation also includes an automatic corona-loss bridge and data logger.

  15. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  16. Protein kinase A stimulates Kv7.1 surface expression by regulating Nedd4-2-dependent endocytic trafficking

    DEFF Research Database (Denmark)

    Andersen, Martin Nybo; Hefting, Louise Leth; Steffensen, Annette Buur

    2015-01-01

    The potassium channel Kv7.1 plays critical physiological roles in both heart and epithelial tissues. In heart, Kv7.1 and the accessory subunit KCNE1 forms the IKs current, which is enhanced by PKA mediated phosphorylation. The observed current increase requires both phosphorylation of Kv7.......1 and the presence of KCNE1. However, PKA also stimulates Kv7.1 currents in epithelial tissues, such as colon, where the channel does not co-assemble with KCNE1. Here, we demonstrate that PKA activity significantly impacts the subcellular localization of Kv7.1 in Madin Darby Canine Kidney cells. While PKA inhibition...... reduced the fraction of channels at the cell surface, PKA activation increased it. We show that PKA inhibition lead to intracellular accumulation of Kv7.1 in late endosomes/lysosomes. By mass spectroscopy we identified eight phosphorylated residues on Kv7.1, however, none appeared to play a role...

  17. Major Refit for CERN's 400 kV Substation (Part of the new control and protection system for the 18 kV side)

    CERN Document Server

    2001-01-01

    The 400 kV substation on the Prévessin site brings in the electricity that powers CERN's accelerators and the majority of the Laboratory's installations. It was originally built in the 1970s for the SPS, and is one of only five privately owned 400 kV sub-stations in France. Three of the others belong to the national railway company, SNCF, supplying the Paris-Marseilles TGV line, the other is at the Cadarache research centre near mouth of the Rhone. After nearly thirty years of service, CERN's substation has just undergone a complete overhaul.

  18. The perceived health risks of indoor radon gas and overhead powerlines: a comparative multilevel approach.

    Science.gov (United States)

    Poortinga, Wouter; Cox, Patrick; Pidgeon, Nick F

    2008-02-01

    Radon and overhead powerlines are two radiation risk cases that have raised varying levels of concern among the general public and experts. Despite both involving radiation-a typically feared and unseen health hazard-individuals' perceptions of the two risk cases may invoke rather different factors. We examined individual and geographic-contextual factors influencing public perceptions of the health risks of indoor radon gas and overhead powerlines in a comparative research design, utilizing a postal questionnaire with 1,528 members of the general public (response rate 28%) and multilevel modeling techniques. This study found that beliefs about the two risk cases mainly differed according to the level of "exposure"-defined here in terms of spatial proximity. We argue that there are two alternative explanations for this pattern of findings: that risk perception itself varies directly with proximity, or that risk is more salient to concerned people in the exposed areas. We also found that while people living in high radon areas are more concerned about the risks of indoor radon gas, they find these risks more acceptable and have more trust in authorities. These results might reflect the positive effects of successive radon campaigns in high radon areas, which may have raised awareness and concern, and at the same time may have helped to increase trust by showing that the government takes the health risks of indoor radon gas seriously, suggesting that genuine risk communication initiatives may have positive impacts on trust in risk management institutions.

  19. Prevention of shoulder injuries in overhead athletes: a science-based approach

    Directory of Open Access Journals (Sweden)

    Ann M. Cools

    2015-10-01

    Full Text Available The shoulder is at high risk for injury during overhead sports, in particular in throwing or hitting activities, such as baseball, tennis, handball, and volleyball. In order to create a scientific basis for the prevention of recurrent injuries in overhead athletes, four steps need to be undertaken: (1 risk factors for injury and re-injury need to be defined; (2 established risk factors may be used as return-to-play criteria, with cut-off values based on normative databases; (3 these variables need to be measured using reliable, valid assessment tools and procedures; and (4 preventative training programs need to be designed and implemented into the training program of the athlete in order to prevent re-injury. In general, three risk factors have been defined that may form the basis for recommendations for the prevention of recurrent injury and return to play after injury: glenohumeral internal-rotation deficit (GIRD; rotator cuff strength, in particular the strength of the external rotators; and scapular dyskinesis, in particular scapular position and strength.

  20. Unevenness of Sliding Surface of Overhead Rigid Conductor Lines and Method for Reducing Unevenness

    Science.gov (United States)

    Aboshi, Mitsuo; Shimizu, Masashi

    Rigid conductor lines are used in many subways, because the use of such conductor lines reduces the risk of accidents and because less space is required for their installation. However, as the unevenness of the sliding surface of the rigid conductor lines significantly influences the fluctuations in the contact force between pantographs and contact lines, it is necessary to decrease the unevenness at the construction as well as the maintenance stages. In order to investigate the installation accuracy of overhead rigid conductor lines, we have developed a device that accurately and continuously measures the unevenness of the sliding surface. By using this measuring device, we have confirmed that the unevenness of the sliding surface depends on various factors such as the sag between the support points, the deformation of the aluminum base or the conductive rail in the case of a long wavelength, the slight sagging unevenness between the bolts of the long ear, the undulating wear etc. This paper describes the actual unevenness conditions and the technical methods for decreasing the unevenness of the sliding surface of overhead rigid conductor lines.

  1. The Influence of Overhead Cranes in the Seismic Performance of Industrial Buildings

    Directory of Open Access Journals (Sweden)

    Andrea Belleri

    2017-11-01

    Full Text Available This paper investigates the influence of overhead cranes with a hanging mass under earthquake type loading, considering the Emilia 2012 seismic sequence. The structural layout of precast concrete industrial buildings typical of the Italian territory is considered. The equations of motion describing the behavior of the hoist load are derived, and a sensitivity analysis is carried out on simplified 3 degrees of freedom systems by solving the governing differential equations. The influence of various parameters on the roof displacement and on the horizontal load transferred by the hanging mass is addressed. The considered parameters are the relative damping of the hanging mass, the length of the hoist ropes, the earthquake record, the hysteretic type of the plastic hinges at the column base, and the behavior factor of the structural system. The results show that for a horizontal component of the considered seismic sequence the structural displacements are amplified in the case of a behavior factor greater than 2.5. A simplified modeling strategy considering small displacements is also investigated. Such model is suitable for response-spectrum analyses. Finally, a three-dimensional case study is analyzed by means of non-linear time history analyses. The results show the influence of the overhead crane on the local performance of some structural and non-structural elements, such as columns and cladding panels, especially when the assumption of rigid roof diaphragm does not apply.

  2. Uptake and Accumulation of Pharmaceuticals in Overhead- and Surface-Irrigated Greenhouse Lettuce.

    Science.gov (United States)

    Bhalsod, Gemini D; Chuang, Ya-Hui; Jeon, Sangho; Gui, Wenjun; Li, Hui; Ryser, Elliot T; Guber, Andrey K; Zhang, Wei

    2018-01-31

    Understanding the uptake and accumulation of pharmaceuticals in vegetables under typical irrigation practices is critical to risk assessment of crop irrigation with reclaimed water. This study investigated the pharmaceutical residues in greenhouse lettuce under overhead and soil-surface irrigations using pharmaceutical-contaminated water. Compared to soil-surface irrigation, overhead irrigation substantially increased the pharmaceutical residues in lettuce shoots. The increased residue levels persisted even after washing for trimethoprim, monensin sodium, and tylosin, indicating their strong sorption to the shoots. The postwashing concentrations in fresh shoots varied from 0.05 ± 0.04 μg/kg for sulfadiazine to 345 ± 139 μg/kg for carbamazepine. Root concentration factors ranged from 0.04 ± 0.14 for tylosin to 19.2 ± 15.7 for sulfamethoxazole. Translocation factors in surface-irrigated lettuce were low for sulfamethoxalzole, trimethoprim, monensin sodium, and tylosin (0.07-0.15), but high for caffeine (4.28 ± 3.01) and carbamazepine (8.15 ± 2.87). Carbamazepine was persistent in soil and hyperaccumulated in shoots.

  3. Households' willingness to pay for overhead-to-underground conversion of electricity distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    McNair, Ben J., E-mail: Ben.McNair@anu.edu.a [Crawford School of Economics and Government, Australian National University, Crawford Building, Lennox Crossing, Canberra ACT 0200 (Australia); Bennett, Jeff [Crawford School of Economics and Government, Australian National University, Crawford Building, Lennox Crossing, Canberra ACT 0200 (Australia); Hensher, David A.; Rose, John M. [Institute of Transport and Logistics Studies, The Business School, University of Sydney, NSW 2006 (Australia)

    2011-05-15

    Underground low-voltage electricity networks have several advantages over overhead networks including reliability of supply, safety and improved visual amenity. The economic viability of replacing existing overhead networks with new underground networks depends on the value of these benefits to households, but no complete value estimates are available in the literature. This paper represents a contribution towards addressing this research gap. A stated choice survey is used to estimate willingness to pay for undergrounding in established residential areas in Canberra, Australia. Average willingness to pay is at least A$6838 per household and there is significant variation in preferences over the population. The results suggest that benefits would be highest in areas with higher household income and older residents where visual amenity, safety, tree trimming, or restrictions on the use of yard space are of concern. - Research highlights: {yields} A choice experiment is used to estimate values for undergrounding electricity wires. {yields} Average willingness to pay is at least A$6838 per household in Canberra, Australia. {yields} Preferences vary considerably over the population. {yields} Benefits would be highest in areas with higher income and older residents.

  4. Effects of Kinesio taping on scapular kinematics of overhead athletes following muscle fatigue.

    Science.gov (United States)

    Zanca, Gisele Garcia; Grüninger, Bruno; Mattiello, Stela Márcia

    2016-08-01

    Scapular kinematics alterations have been found following muscle fatigue. Considering the importance of the lower trapezius in coordinated scapular movement, this study aimed to investigate the effects of elastic taping (Kinesio taping, KT) for muscle facilitation on scapular kinematics of healthy overhead athletes following muscle fatigue. Twenty-eight athletes were evaluated in a crossover, single-blind, randomized design, in three sessions: control (no taping), KT (KT with tension) and sham (KT without tension). Scapular tridimensional kinematics and EMG of clavicular and acromial portions of upper trapezius, lower trapezius and serratus anterior were evaluated during arm elevation and lowering, before and after a fatigue protocol involving repetitive throwing. Median power frequency decline of serratus anterior was significantly lower in KT session compared to sham, possibly indicating lower muscle fatigue. However, the effects of muscle fatigue on scapular kinematics were not altered by taping conditions. Although significant changes were found in scapular kinematics following muscle fatigue, they were small and not considered relevant. It was concluded that healthy overhead athletes seem to present an adaptive mechanism that avoids the disruption of scapular movement pattern following muscle fatigue. Therefore, these athletes do not benefit from the use of KT to assist scapular movement under the conditions tested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. High-tension electrical-arc-induced thermal burns caused by railway overhead cables.

    Science.gov (United States)

    Koller, J

    1991-10-01

    Eleven patients with high-tension electrical-arc-induced thermal burns due to railway overhead cables were treated at the Bratislava Burn Department during a relatively short period of 18 months. All the injuries occurred by the same mechanism, that is persons climbing on top of railway carriages and approaching the 25,000 V a.c. overhead cables. All the burns were the result of an electrical arc passing externally to the body, with subsequent ignition of the victim's clothes. The cutaneous burns, ranging from 24 to 79 per cent of the BSA, were mostly deep partial to full skin thickness injuries. One patient died on day 5 postburn, the other survived. In spite of high-tension aetiology, no true electrical injuries appear to have occurred and no amputations were necessary. The pathophysiology and possible preventive measures are discussed. It must be stressed that arcing can be induced by an earthed object approaching, but not touching, a cable carrying a high voltage.

  6. S-22: Upper Extremity Plyometric Training for the Pediatric Overhead Athletes; Randomized Controled Trial

    Directory of Open Access Journals (Sweden)

    Elif Turgut

    2017-03-01

    Full Text Available INTRODUCTION/ PURPOSE: The purpose of the current study was to investigate the effects of a 12-week upper extremity plyometric training program on upper body explosive power, strength and endurance in pediatric overhead athletes.MATERIALS-METHOD: Twenty-eight female pediatric volleyball players participated in the study. The participants were randomly divided into two study groups: an intervention group (upper extremity plyometric training, n = 14 and a control group (n = 14. All of the participants were assessed before and after a 12-week training program for upper body explosive power, strength and endurance. Statistical comparison was performed using an analysis of variance test. FINDINGS: Comparisons showed that after a 12-week training program, the upper body plyometric training program resulted in more improvements in an overhead medicine-ball throwing distance and a push-up performance when compared to control training. DISCUSSION / CONCLUSION: Compared to regular training, upper body plyometric training resulted in additional improvements in upper body power and strength and endurance among female pediatric volleyball players. The findings of the study provide a basis for developing training protocols for pediatric volleyball players.

  7. Low-altitude overhead imagery acquisition pre- and post-NPE

    Energy Technology Data Exchange (ETDEWEB)

    Pickles, W.L. [Lawerence Livermore National Lab., CA (United States); Shines, J.E.; Hawley, D.L. [and others

    1994-12-31

    We have successfully acquired all the planned overhead imagery (OHI) of the Non-Proliferation Experiment (NPE). The data set is very large and complete. Image mosaics of the area around the NPE Ground Zero (GZ) were taken at 37 12.6948N by 116 12 35.496W on top of Rainier Mesa in Areas 12 at NTS. The data were taken from a total of eight overflights on six different days. Preliminary analysis of the thermal infrared, 8-12.5-micron scanner band, taken before and after the NPE, shows some low-emission effects in virgin soil after the NPE. These effects could be due to the acceleration of the surface caused by NPE. Preliminary analysis of the visible high-resolution color RC-30 photography shows the senescence of oak leaves in an areas of 2 km around GZ. Several other groups also independently observed this phenomenon when they returned to the mesa on Friday morning, 48 hours after the NPE. Detailed study of the photography and the scanner data will be necessary to map the actual aerial extent of the senescence. If the effect is proven to be limited to the area around GZ, then we will have supporting evidence that we have actually observed shock-induced premature senescence of oak leaves. Such overhead imagery could be used to help reduce the search area during an on-site inspection as part of the Comprehensive Test Ban Treaty verification activities.

  8. Overhead work and shoulder-neck pain in orchard farmers harvesting pears and apples.

    Science.gov (United States)

    Sakakibara, H; Miyao, M; Kondo, T; Yamada, S

    1995-04-01

    The effects of overhead work were studied by comparing orchard farmers' musculoskeletal symptoms while bagging pears with those same symptoms while bagging apples. The subjects were 52 Japanese female farmers, who were examined twice an evening in late June for bagging pears, and during another evening of late July for bagging apples, when each task had been almost finished. They were questioned about musculoskeletal complaints of stiffness and pain during each job, and examined for muscle tenderness and pain from joint movement. Arm elevation angles during the work were measured for each type of bagging. The prevalence of stiffness and pain in the neck and shoulder, muscle tenderness in the shoulder regions, and pain in neck motion were found to be significantly higher when bagging pears than apples. Musculoskeletal symptoms of parts other than the neck and shoulder did not differ between the two types of bagging. The working posture of elevating the arm more than 90 degrees was assumed to account for 75% of the time bagging pears, against 40% for bagging apples. Overhead work requiring arm elevation and head extension was considered to be closely related with shoulder-neck disorders among farmers.

  9. A 600-kV double-pulser for the PHERMEX electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, R.L.; Kang, M.; Melton, J.G.; Seitz, G.J.; Trujillo, L.T.

    1997-09-01

    The PHERMEX (Pulsed High Energy Radiographic Machine Emitting X-rays) Radiographic Facility is a 50-MHz, 3-Cavity, RF-Linac driven by a pulsed, thermionic electron-gun Injector. The PHERMEX is used to take flash radiographs using x-rays at a single time in an explosively driven event. To investigate the time evolution of these events requires two things: (1) a multiple-pulser to drive the electron-gun Injector and (2) a large-format, gamma-ray, camera system to record a scintillator at the different times. The authors report the recent success of developing a reliable double-pulser that consists of two Marx generators that independently charge two PFLs that are switched out at about 1.4 MV. The PFLs are connected in series by large diaphragm switches that are independently laser triggered by two quadrupled-YAG lasers. Recent tests of the system into a dummy load, produced two high quality 600 kV pulses separated by 1.0 {micro}s. Each pulse has a FWHM of 90 ns, a 50 ns flat-top {+-} 3%, and a risetime of 25 ns and a falltime of 35 ns. The interpulse time is variable up to about 275 {micro}s; the first switch is kept closed by a keep alive inductor. The system has produced a 50 shot sequence of two pulses with a 1-sigma jitter < 1 ns. The system has been modeled using TOSCA-3D, FLUX-2D, and a transmission line model run with the circuits code Micro-CAP.

  10. A 600-kV double-pulser for the PHERMEX electron gun

    International Nuclear Information System (INIS)

    Carlson, R.L.; Kang, M.; Melton, J.G.; Seitz, G.J.; Trujillo, L.T.

    1997-01-01

    The PHERMEX (Pulsed High Energy Radiographic Machine Emitting X-rays) Radiographic Facility is a 50-MHz, 3-Cavity, RF-Linac driven by a pulsed, thermionic electron-gun Injector. The PHERMEX is used to take flash radiographs using x-rays at a single time in an explosively driven event. To investigate the time evolution of these events requires two things: (1) a multiple-pulser to drive the electron-gun Injector and (2) a large-format, gamma-ray, camera system to record a scintillator at the different times. The authors report the recent success of developing a reliable double-pulser that consists of two Marx generators that independently charge two PFLs that are switched out at about 1.4 MV. The PFLs are connected in series by large diaphragm switches that are independently laser triggered by two quadrupled-YAG lasers. Recent tests of the system into a dummy load, produced two high quality 600 kV pulses separated by 1.0 micros. Each pulse has a FWHM of 90 ns, a 50 ns flat-top ± 3%, and a risetime of 25 ns and a falltime of 35 ns. The interpulse time is variable up to about 275 micros; the first switch is kept closed by a keep alive inductor. The system has produced a 50 shot sequence of two pulses with a 1-sigma jitter < 1 ns. The system has been modeled using TOSCA-3D, FLUX-2D, and a transmission line model run with the circuits code Micro-CAP

  11. Regulation of Kv1.4 potassium channels by PKC and AMPK kinases

    DEFF Research Database (Denmark)

    Andersen, Martin Nybo; Skibsbye, Lasse; Saljic, Arnela

    2018-01-01

    around the ubiquitin ligase Nedd4-2. In the present study we examined whether Kv1.4, constituting the cardiac Ito,s current, is subject to similar regulation. In the epithelial Madin-Darby Canine Kidney (MDCK) cell line, which constitutes a highly reproducible model system for addressing membrane...... targeting, we find, by confocal microscopy, that Kv1.4 cell surface expression is downregulated by activation of protein kinase C (PKC) and AMP-activated protein kinase (AMPK). In contrast, manipulating the activities of phosphatidylinositol-4,5-bisphosphate 3-kinase (PI3K) and serum and glucocorticoid......-regulated kinase 1 (SGK1) were without effect on channel localization. The PKC and AMPK-mediated downregulation of Kv1.4 membrane surface localization was confirmed by two-electrode voltage clamp in Xenopus laevis oocytes, where pharmacological activation of PKC and AMPK reduced Kv1.4 current levels. We further...

  12. Downregulation of Kv7.4 channel activity in primary and secondary hypertension

    DEFF Research Database (Denmark)

    Jepps, Thomas Andrew; Chadha, Preet S; Davis, Alison J

    2011-01-01

    Voltage-gated potassium (K(+)) channels encoded by KCNQ genes (Kv7 channels) have been identified in various rodent and human blood vessels as key regulators of vascular tone; however, nothing is known about the functional impact of these channels in vascular disease. We ascertained the effect of...... structurally different activators of Kv7.2 through Kv7.5 channels (BMS-204352, S-1, and retigabine) on blood vessels from normotensive and hypertensive animals.......Voltage-gated potassium (K(+)) channels encoded by KCNQ genes (Kv7 channels) have been identified in various rodent and human blood vessels as key regulators of vascular tone; however, nothing is known about the functional impact of these channels in vascular disease. We ascertained the effect of 3...

  13. Kv7.1 surface expression is regulated by epithelial cell polarization

    DEFF Research Database (Denmark)

    Andersen, Martin N; Olesen, Søren-Peter; Rasmussen, Hanne Borger

    2011-01-01

    The potassium channel K(V)7.1 is expressed in the heart where it contributes to the repolarization of the cardiac action potential. In addition, K(V)7.1 is expressed in epithelial tissues where it plays a role in salt and water transport. Mutations in the kcnq1 gene can lead to long QT syndrome...... and deafness, and several mutations have been described as trafficking mutations. To learn more about the basic mechanisms that regulate K(V)7.1 surface expression, we have investigated the trafficking of K(V)7.1 during the polarization process of the epithelial cell line Madin-Darby Canine Kidney (MDCK) using...... is regulated by signaling mechanisms involved in epithelial cell polarization in particular signaling cascades involving protein kinase C and PI3K....

  14. A comparison of kV and MV imaging in head and neck image guided radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Devereux, B. [Radiation Oncology Queensland, 280 North St, Toowoomba 4350 (Australia)], E-mail: beth.devereux@roq.net.au; Frantzis, J.; Sisson, T.; Jones, M.; Martin, J.; Middleton, M. [Radiation Oncology Queensland, 280 North St, Toowoomba 4350 (Australia)

    2010-02-15

    Purpose: To compare and assess kV and MV imaging modalities and their role in image guided radiotherapy (IGRT) for head and neck cancer patients. Method: Twelve patients receiving radical radiotherapy to the head and neck were analysed in this study. Six patients undertook MV daily online intervention and a further six patients undertook kV daily online intervention. Pre-intervention field placement data were collected from three separate observers' image match analysis for each patient. The radiotherapy collective involved in the daily online image match analysis formed the fourth observer in the study. The primary end point was to establish the difference in inter- and intra-observer variance between kV and MV imaging modalities. Results: The range of the standard deviations of systematic set-up error for MV imaging calculated was 1.47-2.33 mm (MV) and 1.61-1.64 mm (kV) for the right-left (RL), 2.10-2.17 mm (MV) and 1.53-1.84 mm (kV) for the cranio-caudal (CC) and 1.43-1.63 mm (MV) and 1.02-1.11 mm (kV) for the anterior-posterior (AP). The mean inter-observer variance was 0.21 mm (MV) and 0.41 mm (kV) for the RL, 0.53 mm (MV) and 0.55 mm (kV) for the CC and 0.23 mm (MV) and 0.16 mm (kV) for the AP direction. Intra-observer mean variance was in the order of 0.60 mm (MV) and 0.16 mm (kV) for the RL, 1.41 mm (MV) and 0.05 mm (kV) for the CC and 1.41 mm (MV) and 0.08 mm (kV) for the AP. Discussion: The data in this study suggest both inter- and intra-observer consistency across kV and MV imaging modalities were comparable. However, it is felt that the improved clarity and quality of kV imaging allows all observers to analyse images in a consistent manner, identifying and acting on potential field placement moves. Conclusion: The introduction of kV imaging has maintained the high levels of inter- and intra-observer consistency achieved with MV imaging. This in turn further enables positive verification outcomes and supports the implementation of potential

  15. The development of a 200 kV monochromated field emission electron source

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Masaki, E-mail: mmukai@jeol.co.jp [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Kim, Judy S. [University of Oxford, Department of Materials, Parks Road, Oxford, OX1 3PH (United Kingdom); Omoto, Kazuya; Sawada, Hidetaka; Kimura, Atsushi; Ikeda, Akihiro; Zhou, Jun; Kaneyama, Toshikatsu [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Young, Neil P.; Warner, Jamie H.; Nellist, Peter D.; Kirkland, Angus I. [University of Oxford, Department of Materials, Parks Road, Oxford, OX1 3PH (United Kingdom)

    2014-05-01

    We report the development of a monochromator for an intermediate-voltage aberration-corrected electron microscope suitable for operation in both STEM and TEM imaging modes. The monochromator consists of two Wien filters with a variable energy selecting slit located between them and is located prior to the accelerator. The second filter cancels the energy dispersion produced by the first filter and after energy selection forms a round monochromated, achromatic probe at the specimen plane. The ultimate achievable energy resolution has been measured as 36 meV at 200 kV and 26 meV at 80 kV. High-resolution Annular Dark Field STEM images recorded using a monochromated probe resolve Si–Si spacings of 135.8 pm using energy spreads of 218 meV at 200 kV and 217 meV at 80 kV respectively. In TEM mode an improvement in non-linear spatial resolution to 64 pm due to the reduction in the effects of partial temporal coherence has been demonstrated using broad beam illumination with an energy spread of 134 meV at 200 kV. - Highlights: • Monochromator for 200 kV aberration corrected TEM and STEM was developed. • Monochromator produces monochromated and achromatic probe at specimen plane. • Ultimate energy resolution was measured to be 36 meV at 200 kV and 26 meV at 80 kV. • Atomic resolution STEM images were recorded using monochromated electron probe. • Improvements of TEM resolution were confirmed using monochromated illumination.

  16. Effects of the small molecule HERG activator NS1643 on Kv11.3 channels.

    Directory of Open Access Journals (Sweden)

    Arne Bilet

    Full Text Available NS1643 is one of the small molecule HERG (Kv11.1 channel activators and has also been found to increase erg2 (Kv11.2 currents. We now investigated whether NS1643 is also able to act as an activator of Kv11.3 (erg3 channels expressed in CHO cells. Activation of rat Kv11.3 current occurred in a dose-dependent manner and maximal current increasing effects were obtained with 10 µM NS1643. At this concentration, steady-state outward current increased by about 80% and the current increase was associated with a significant shift in the voltage dependence of activation to more negative potentials by about 15 mV. In addition, activation kinetics were accelerated, whereas deactivation was slowed. There was no significant effect on the kinetics of inactivation and recovery from inactivation. The strong current-activating agonistic effect of NS1643 did not result from a shift in the voltage dependence of Kv11.3 channel inactivation and was independent from external Na(+ or Ca(2+. At the higher concentration of 20 µM, NS1643 induced clearly less current increase. The left shift in the voltage dependence of activation reversed and the voltage sensitivity of activation dramatically decreased along with a slowing of Kv11.3 channel activation. These data show that, in comparison to other Kv11 family members, NS1643 exerts distinct effects on Kv11.3 channels with especially pronounced partial antagonistic effects at higher concentration.

  17. The development of a 200 kV monochromated field emission electron source

    International Nuclear Information System (INIS)

    Mukai, Masaki; Kim, Judy S.; Omoto, Kazuya; Sawada, Hidetaka; Kimura, Atsushi; Ikeda, Akihiro; Zhou, Jun; Kaneyama, Toshikatsu; Young, Neil P.; Warner, Jamie H.; Nellist, Peter D.; Kirkland, Angus I.

    2014-01-01

    We report the development of a monochromator for an intermediate-voltage aberration-corrected electron microscope suitable for operation in both STEM and TEM imaging modes. The monochromator consists of two Wien filters with a variable energy selecting slit located between them and is located prior to the accelerator. The second filter cancels the energy dispersion produced by the first filter and after energy selection forms a round monochromated, achromatic probe at the specimen plane. The ultimate achievable energy resolution has been measured as 36 meV at 200 kV and 26 meV at 80 kV. High-resolution Annular Dark Field STEM images recorded using a monochromated probe resolve Si–Si spacings of 135.8 pm using energy spreads of 218 meV at 200 kV and 217 meV at 80 kV respectively. In TEM mode an improvement in non-linear spatial resolution to 64 pm due to the reduction in the effects of partial temporal coherence has been demonstrated using broad beam illumination with an energy spread of 134 meV at 200 kV. - Highlights: • Monochromator for 200 kV aberration corrected TEM and STEM was developed. • Monochromator produces monochromated and achromatic probe at specimen plane. • Ultimate energy resolution was measured to be 36 meV at 200 kV and 26 meV at 80 kV. • Atomic resolution STEM images were recorded using monochromated electron probe. • Improvements of TEM resolution were confirmed using monochromated illumination

  18. 40-kV, 25-ms neutral-beam power supply for TMX

    International Nuclear Information System (INIS)

    Leavitt, G.A.

    1977-01-01

    Modifications are described to upgrade the neutral-beam power supply for the TMX from 40 kV, 10 ms to 40 kV, 25 ms. The redesign of the accel and suppressor power supplies to achieve separation of the high-voltage and control sections, operation of the arc pulse lines in series, operation of the arc pulse lines in a noisy environment with SCR trigger and crowbar, and modifications to the electrolytic storage banks are discussed

  19. Analisa Penggunaan Recloser untuk Pengaman Arus Lebih pada Jaringan Distribusi 20 Kv Gardu Induk Garuda Sakti

    OpenAIRE

    Putra, Ario; Firdaus, Firdaus

    2017-01-01

    PT.PLN: 20 kV network substations Garuda Sakti, frequently interference, one of interferences is the short-circuit current. To install equipment to include Recloser. This paper discuss the analysisof the use Recloser on distribution network 20 kV, this paper also be simulated using the software ETAP 12.6 which will feature some of the parameters for comparison of calculations and data thatalready exists in PLN, with two parameters, short circuit and coordination Recloser with overcurrent rela...

  20. Canby Area Service Project substation and associated transmission line

    International Nuclear Information System (INIS)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ''environmental impact statement'' is not required

  1. 107.5 Gb/s 850 nm multi- and single-mode VCSEL transmission over 10 and 100 m of multi-mode fiber

    DEFF Research Database (Denmark)

    Puerta Ramírez, Rafael; Agustin, M.; Chorchos, L.

    2016-01-01

    First time successful 107.5 Gb/s MultiCAP 850 nm OM4 MMF transmissions over 10 m with multi-mode VCSEL and up to 100 m with single-mode VCSEL are demonstrated, with BER below 7% overhead FEC limit measured for each case.......First time successful 107.5 Gb/s MultiCAP 850 nm OM4 MMF transmissions over 10 m with multi-mode VCSEL and up to 100 m with single-mode VCSEL are demonstrated, with BER below 7% overhead FEC limit measured for each case....

  2. Regulation of KV channel voltage-dependent activation by transmembrane β subunits

    Directory of Open Access Journals (Sweden)

    Xiaohui eSun

    2012-04-01

    Full Text Available Voltage-activated K+ (KV channels are important for shaping action potentials and maintaining resting membrane potential in excitable cells. KV channels contain a central pore-gate domain (PGD surrounded by four voltage-sensing domains (VSD. The VSDs will change conformation in response to alterations of the membrane potential thereby inducing the opening of the PGD. Many KV channels are heteromeric protein complexes containing auxiliary β subunits. These β subunits modulate channel expression and activity to increase functional diversity and render tissue specific phenotypes. This review focuses on the KV β subunits that contain transmembrane (TM segments including the KCNE family and the β subunits of large conductance, Ca2+- and voltage-activated K+ (BK channels. These TM β subunits affect the voltage-dependent activation of KV α subunits. Experimental and computational studies have described the structural location of these β subunits in the channel complexes and the biophysical effects on VSD activation, PGD opening and VSD-PGD coupling. These results reveal some common characteristics and mechanistic insights into KV channel modulation by TM β subunits.

  3. Final configuration with assembly assessment of the 100 kV high voltage bushing for the Indian test facility

    International Nuclear Information System (INIS)

    Sharma, Dheeraj Kumar; Shah, Sejal; Venkata Nagaraju, M.; Bandyopadhyay, Mainak; Rotti, Chandramouli; Chakraborty, Arun Kumar

    2015-01-01

    The Indian Test Facility (INTF) of Neutral Beam (NB) system is an Indian voluntary effort for the full characterization of the diagnostic neutral beam which is the part of ITER's neutral beam system. The design activities of INTF NB system are completed. The INTF High Voltage Bushing (HVB), which is one of the component of NB system, is designed to connect all the required feedlines, e.g. electrical busbars, RF co-axial lines, diagnostic lines and hydraulic and gas feed lines, carried by the transmission line from the HV deck to the Beam Source of NB system. It forms the primary vacuum boundary and provides 100 kV isolation for INTF beam operation. The entire feedlines pass through a metallic plate of HVB called Dished Head (DH) where all the feedlines converge. The overall diameter of DH is 847 mm which is governed by the diameter of the Porcelain insulator which is meant for 100 kV isolation. The effective diameter where all the feedlines converge at the dished head is ∼ 600 mm which is quite a challenge to accommodate 26 feedlines each of average diameter 60 mm. Electrical feedlines require Vacuum-Electrical feedthroughs for voltage isolation whereas water and gas lines are considered to be directly welded with the DH except one water line which requires 12 kV voltage isolation with respect to DH. For RF lines, different scheme is considered which includes separate Electrical Feedthrough and Vacuum Barrier. To provide connection to electrical cables of heaters and thermocouples, 4 numbers of multipin vacuum compatible electrical feedthroughs are provided which can accommodate ∼250 cables. Due to space constraints, Vacuum-Electrical Feedthroughs are considered to be welded with the DH and therefore they shall be of metal-ceramic-metal configuration to allow welding. To avoid undue loading on the ceramic part, the feedlines are supported additionally at DH using vacuum compatible and electrically insulating material. One more important aspect of the INTF

  4. System impact assessment report 115 kV interconnection between Cornwall system and Hydro One : final report

    International Nuclear Information System (INIS)

    2005-01-01

    Cornwall Electric (CE) is the local distribution company that serves the City of Cornwall, Ontario. The utility can be supplied from either Hydro Quebec, New York ISO or the IESO. CE has proposed to connect Rosemount, McConnell and Courtaulds substations to the IESO-controlled grid in order to obtain access to the competitively priced electricity in Ontario. The load connected to the 2 substations peaks in winter at about 100 MW. The 2 substations will be connected in stages. Only 40 MW of load from the Rosemount substation will be connected initially, followed by up to 100 MW from the McConnell and Courtaulds substation at a later date. The connection will be made through a circuit that taps into the St. Lawrence transmission station in Ontario. A new circuit will also be built and strung on existing towers. This document described the requirements for under-frequency load shedding; voltage reduction facilities; power factor; on-line monitoring; and system protections. According to data provided by Hydro One, the circuit is adequately rated to accommodate connection of the load from the Rosemount and McConnell and Courtaulds substations with no thermal overloading concerns. Winter load conditions were also considered. However, the IESO noted a potential reliability concern in the event that the Cardinal Power generating station is out of service and only one of the transformers connecting St. Lawrence 230 kV bus to St. Lawrence 115 kV bus is in service. However, the power transfers rated at 250 MVA are within the continuous rating of one transformer. It was concluded that the connection of the new load does not have an impact on the short circuit current at the St. Lawrence transmission station. The continuous thermal rating of the circuit is considered to be adequate for the proposed 100 MW of load transfer and the rating of the new line is sufficient to supply the total load at McConnell and Courtaulds. The ratings of the new disconnect switches meet market

  5. Fault and load flows analysis of electricity transmission and distribution system in Casanare (Colombia)

    OpenAIRE

    Castro-Galeano, Juan Carlos; Cabra-Sarmiento, Wilson Javier; Ortiz-Portilla, Jhony Fernando

    2017-01-01

    Abstract This article describes a simulation of the electrical local distribution and regional transmission system of Enerca S.A. E.S.P. at 34.5 kV and 115 kV, identifying the most critical circuits and substations. The company is located in one of the major petroleum production areas in Colombia, and because of a massive growth in this sector, the electrical company expanded its networks in a radial way. This expansion was improvised and poorly planned due to the accelerated need to meet the...

  6. Penerapan Sistem ABC (Activity Based Costing System) Sebagai Alternatif Dasar Pembebanan Biaya Overhead Pabrik (Studi Kasus Pada PT. Wonojati Wijoyo Kediri Jawa Timur)”

    OpenAIRE

    Ahmad Putri, Dian Rahmawati; Saifi, Muhammad; Hidayat, Raden Rustam

    2016-01-01

    The purpose of this study to determine the company's factory overhead charges and to find out the imposition of factory overhead costs using ABC System (Activity Based Costing System).This type of research used in this research is descriptive case study approach. ABC System (Activity Based Costing System) is a way to replace the traditional cost accounting methods have many disadvantages in determining overhead costs ,because in the application of the ABC System (Activity Based Costing System...

  7. Priority image transmission in wireless sensor networks

    International Nuclear Information System (INIS)

    Nasri, M.; Helali, A.; Sghaier, H.; Maaref, H.

    2011-01-01

    The emerging technology during the last years allowed the development of new sensors equipped with wireless communication which can be organized into a cooperative autonomous network. Some application areas for wireless sensor networks (WSNs) are home automations, health care services, military domain, and environment monitoring. The required constraints are limited capacity of processing, limited storage capability, and especially these nodes are limited in energy. In addition, such networks are tiny battery powered which their lifetime is very limited. During image processing and transmission to the destination, the lifetime of sensor network is decreased quickly due to battery and processing power constraints. Therefore, digital image transmissions are a significant challenge for image sensor based Wireless Sensor Networks (WSNs). Based on a wavelet image compression, we propose a novel, robust and energy-efficient scheme, called Priority Image Transmission (PIT) in WSN by providing various priority levels during image transmissions. Different priorities in the compressed image are considered. The information for the significant wavelet coeffcients are transmitted with higher quality assurance, whereas relatively less important coefficients are transmitted with lower overhead. Simulation results show that the proposed scheme prolongs the system lifetime and achieves higher energy efficiency in WSN with an acceptable compromise on the image quality.

  8. Shoulder External Rotation Fatigue and Scapular Muscle Activation and Kinematics in Overhead Athletes

    Science.gov (United States)

    Joshi, Mithun; Thigpen, Charles A.; Bunn, Kevin; Karas, Spero G.; Padua, Darin A.

    2011-01-01

    Context: Glenohumeral external rotation (GH ER) muscle fatigue might contribute to shoulder injuries in overhead athletes. Few researchers have examined the effect of such fatigue on scapular kinematics and muscle activation during a functional movement pattern. Objective: To examine the effects of GH ER muscle fatigue on upper trapezius, lower trapezius, serratus anterior, and infraspinatus muscle activation and to examine scapular kinematics during a diagonal movement task in overhead athletes. Setting: Human performance research laboratory. Design: Descriptive laboratory study. Patients or Other Participants: Our study included 25 overhead athletes (15 men, 10 women; age = 20 ± 2 years, height = 180 ± 11 cm, mass = 80 ± 11 kg) without a history of shoulder pain on the dominant side. Interventions: We tested the healthy, dominant shoulder through a diagonal movement task before and after a fatiguing exercise involving low-resistance, high-repetition, prone GH ER from 0° to 75° with the shoulder in 90° of abduction. Main Outcome Measure(s): Surface electromyography was used to measure muscle activity for the upper trapezius, lower trapezius, serratus anterior, and infraspinatus. An electromyographic motion analysis system was used to assess 3-dimensional scapular kinematics. Repeated-measures analyses of variance (phase × condition) were used to test for differences. Results: We found a decrease in ascending-phase and descending-phase lower trapezius activity (F1,25 = 5.098, P = .03) and an increase in descending-phase infraspinatus activity (F1,25 = 5.534, P = .03) after the fatigue protocol. We also found an increase in scapular upward rotation (F1,24 = 3.7, P = .04) postfatigue. Conclusions: The GH ER muscle fatigue protocol used in this study caused decreased lower trapezius and increased infraspinatus activation concurrent with increased scapular upward rotation range of motion during the functional task. This highlights the interdependence of scapular

  9. Retigabine, a Kv7.2/Kv7.3-Channel Opener, Attenuates Drug-Induced Seizures in Knock-In Mice Harboring Kcnq2 Mutations.

    Science.gov (United States)

    Ihara, Yukiko; Tomonoh, Yuko; Deshimaru, Masanobu; Zhang, Bo; Uchida, Taku; Ishii, Atsushi; Hirose, Shinichi

    2016-01-01

    The hetero-tetrameric voltage-gated potassium channel Kv7.2/Kv7.3, which is encoded by KCNQ2 and KCNQ3, plays an important role in limiting network excitability in the neonatal brain. Kv7.2/Kv7.3 dysfunction resulting from KCNQ2 mutations predominantly causes self-limited or benign epilepsy in neonates, but also causes early onset epileptic encephalopathy. Retigabine (RTG), a Kv7.2/ Kv7.3-channel opener, seems to be a rational antiepileptic drug for epilepsies caused by KCNQ2 mutations. We therefore evaluated the effects of RTG on seizures in two strains of knock-in mice harboring different Kcnq2 mutations, in comparison to the effects of phenobarbital (PB), which is the first-line antiepileptic drug for seizures in neonates. The subjects were heterozygous knock-in mice (Kcnq2Y284C/+ and Kcnq2A306T/+) bearing the Y284C or A306T Kcnq2 mutation, respectively, and their wild-type (WT) littermates, at 63-100 days of age. Seizures induced by intraperitoneal injection of kainic acid (KA, 12mg/kg) were recorded using a video-electroencephalography (EEG) monitoring system. Effects of RTG on KA-induced seizures of both strains of knock-in mice were assessed using seizure scores from a modified Racine's scale and compared with those of PB. The number and total duration of spike bursts on EEG and behaviors monitored by video recording were also used to evaluate the effects of RTG and PB. Both Kcnq2Y284C/+ and Kcnq2A306T/+ mice showed significantly more KA-induced seizures than WT mice. RTG significantly attenuated KA-induced seizure activities in both Kcnq2Y284C/+ and Kcnq2A306T/+ mice, and more markedly than PB. This is the first reported evidence of RTG ameliorating KA-induced seizures in knock-in mice bearing mutations of Kcnq2, with more marked effects than those observed with PB. RTG or other Kv7.2-channel openers may be considered as first-line antiepileptic treatments for epilepsies resulting from KCNQ2 mutations.

  10. Spectral and Energy Efficient Low-Overhead Uplink and Downlink Channel Estimation for 5G Massive MIMO Systems

    Directory of Open Access Journals (Sweden)

    Imran Khan

    2018-01-01

    Full Text Available Uplink and Downlink channel estimation in massive Multiple Input Multiple Output (MIMO systems is an intricate issue because of the increasing channel matrix dimensions. The channel feedback overhead using traditional codebook schemes is very large, which consumes more bandwidth and decreases the overall system efficiency. The purpose of this paper is to decrease the channel estimation overhead by taking the advantage of sparse attributes and also to optimize the Energy Efficiency (EE of the system. To cope with this issue, we propose a novel approach by using Compressed-Sensing (CS, Block Iterative-Support-Detection (Block-ISD, Angle-of-Departure (AoD and Structured Compressive Sampling Matching Pursuit (S-CoSaMP algorithms to reduce the channel estimation overhead and compare them with the traditional algorithms. The CS uses temporal-correlation of time-varying channels to produce Differential-Channel Impulse Response (DCIR among two CIRs that are adjacent in time-slots. DCIR has greater sparsity than the conventional CIRs as it can be easily compressed. The Block-ISD uses spatial-correlation of the channels to obtain the block-sparsity which results in lower pilot-overhead. AoD quantizes the channels whose path-AoDs variation is slower than path-gains and such information is utilized for reducing the overhead. S-CoSaMP deploys structured-sparsity to obtain reliable Channel-State-Information (CSI. MATLAB simulation results show that the proposed CS based algorithms reduce the feedback and pilot-overhead by a significant percentage and also improve the system capacity as compared with the traditional algorithms. Moreover, the EE level increases with increasing Base Station (BS density, UE density and lowering hardware impairments level.

  11. T Cell Subset and Stimulation Strength-Dependent Modulation of T Cell Activation by Kv1.3 Blockers.

    Directory of Open Access Journals (Sweden)

    Wai-Ping Fung-Leung

    Full Text Available Kv1.3 is a voltage-gated potassium channel expressed on T cells that plays an important role in T cell activation. Previous studies have shown that blocking Kv1.3 channels in human T cells during activation results in reduced calcium entry, cytokine production, and proliferation. The aim of the present study was to further explore the effects of Kv1.3 blockers on the response of different human T cell subsets under various stimulation conditions. Our studies show that, unlike the immune suppressor cyclosporine A, the inhibitory effect of Kv1.3 blockers was partial and stimulation strength dependent, with reduced inhibitory efficacy on T cells under strengthened anti-CD3/CD28 stimulations. T cell responses to allergens including house dust mites and ragweed were partially reduced by Kv1.3 blockers. The effect of Kv1.3 inhibition was dependent on T cell subsets, with stronger effects on CCR7- effector memory compared to CCR7+ central memory CD4 T cells. Calcium entry studies also revealed a population of CD4 T cells resistant to Kv1.3 blockade. Activation of CD4 T cells was accompanied with an increase in Kv1.3 currents but Kv1.3 transcripts were found to be reduced, suggesting a posttranscriptional mechanism in the regulation of Kv1.3 activities. In summary, Kv1.3 blockers inhibit T cell activation in a manner that is highly dependent on the T cell identity and stimulation strength, These findings suggest that Kv1.3 blockers inhibit T cells in a unique, conditional manner, further refining our understanding of the therapeutic potential of Kv1.3 blockers.

  12. Immunomodulatory effects of diclofenac in leukocytes through the targeting of Kv1.3 voltage-dependent potassium channels.

    Science.gov (United States)

    Villalonga, Núria; David, Miren; Bielańska, Joanna; González, Teresa; Parra, David; Soler, Concepció; Comes, Núria; Valenzuela, Carmen; Felipe, Antonio

    2010-09-15

    Kv1.3 plays a crucial role in the activation and proliferation of T-lymphocytes and macrophages. While Kv1.3 is responsible for the voltage-dependent potassium current in T-cells, in macrophages this K(+) current is generated by the association of Kv1.3 and Kv1.5. Patients with autoimmune diseases show a high number of effector memory T cells that are characterized by a high expression of Kv1.3 and Kv1.3 antagonists ameliorate autoimmune disorders in vivo. Diclofenac is a non-steroidal anti-inflammatory drug (NSAID) used in patients who suffer from painful autoimmune diseases such as rheumatoid arthritis. In this study, we show that diclofenac impairs immune response via a mechanism that involves Kv1.3. While diclofenac inhibited Kv1.3 expression in activated macrophages and T-lymphocytes, Kv1.5 remained unaffected. Diclofenac also decreased iNOS levels in Raw 264.7 cells, impairing their activation in response to lipopolysaccharide (LPS). LPS-induced macrophage migration and IL-2 production in stimulated Jurkat T-cells were also blocked by pharmacological doses of diclofenac. These effects were mimicked by Margatoxin, a specific Kv1.3 inhibitor, and Charybdotoxin, which blocks both Kv1.3 and Ca(2+)-activated K(+) channels (K(Ca)3.1). Because Kv1.3 is a very good target for autoimmune therapies, the effects of diclofenac on Kv1.3 are of high pharmacological relevance. Copyright 2010 Elsevier Inc. All rights reserved.

  13. Steps for arm and trunk actions of overhead forehand stroke used in badminton games across skill levels.

    Science.gov (United States)

    Wang, Jianyu; Liu, Wenhao; Moffit, Jeffrey

    2009-08-01

    The purpose of this study was to examine arm and trunk actions in overhead forehand strokes used in badminton games across skill levels. The participants were 80 students (40 boys, 40 girls) who were randomly selected from video recordings of 300 students ages 16 to 19 years. The videotaped performances of overhead forehand strokes were coded based on three steps of arm action (elbow flexion, elbow and humeral flexion, and upward backswing) and three steps of trunk action (no trunk action, forward-backward movement, and trunk rotation). Students across the four skill levels exhibited different patterns of arm and trunk actions. Students at advanced levels used more mature arm and trunk actions.

  14. High reliability low jitter 80 kV pulse generator

    International Nuclear Information System (INIS)

    Savage, Mark Edward; Stoltzfus, Brian Scott

    2009-01-01

    Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10 (Omega), from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K.W. Struve, W.A. Stygar, L.K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 (Omega), 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10 -4 . The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While

  15. Ground-Wave Propagation Effects on Transmission Lines through Error Images

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-07-01

    Full Text Available Electromagnetic transient calculation of overhead transmission lines is strongly influenced by the natural resistivity of the ground. This varies from 1-10K (Ω·m depending on several media factors and on the physical composition of the ground. The accuracy on the calculation of a system transient response depends in part in the ground return model, which should consider the line geometry, the electrical resistivity and the frequency dependence of the power source. Up to date, there are only a few reports on the specialized literature about analyzing the effects produced by the presence of an imperfectly conducting ground of transmission lines in a transient state. A broad range analysis of three of the most often used ground-return models for calculating electromagnetic transients of overhead transmission lines is performed in this paper. The behavior of modal propagation in ground is analyzed here into effects of first and second order. Finally, a numerical tool based on relative error images is proposed in this paper as an aid for the analyst engineer to estimate the incurred error by using approximate ground-return models when calculating transients of overhead transmission lines.

  16. Transcending Transmission

    DEFF Research Database (Denmark)

    Schoeneborn, Dennis; Trittin, Hannah

    2013-01-01

    Purpose – Extant research on corporate social responsibility (CSR) communication primarily relies on a transmission model of communication that treats organizations and communication as distinct phenomena. This approach has been criticized for neglecting the formative role of communication...... in the emergence of organizations. This paper seeks to propose to reconceptualize CSR communication by drawing on the “communication constitutes organizations” (CCO) perspective. Design/methodology/approach – This is a conceptual paper that explores the implications of switching from an instrumental...... to a constitutive notion of communication. Findings – The study brings forth four main findings: from the CCO view, organizations are constituted by several, partly dissonant, and potentially contradictory communicative practices. From that viewpoint, the potential impact of CSR communication becomes a matter...

  17. Switched Two-Level H∞ and Robust Fuzzy Learning Control of an Overhead Crane

    Directory of Open Access Journals (Sweden)

    Kao-Ting Hung

    2013-01-01

    Full Text Available Overhead cranes are typical dynamic systems which can be modeled as a combination of a nominal linear part and a highly nonlinear part. For such kind of systems, we propose a control scheme that deals with each part separately, yet ensures global Lyapunov stability. The former part is readily controllable by the H∞ PDC techniques, and the latter part is compensated by fuzzy mixture of affine constants, leaving the remaining unmodeled dynamics or modeling error under robust learning control using the Nelder-Mead simplex algorithm. Comparison with the adaptive fuzzy control method is given via simulation studies, and the validity of the proposed control scheme is demonstrated by experiments on a prototype crane system.

  18. Comparing methodologies for the allocation of overhead and capital costs to hospital services.

    Science.gov (United States)

    Tan, Siok Swan; van Ineveld, Bastianus Martinus; Redekop, William Ken; Hakkaart-van Roijen, Leona

    2009-06-01

    Typically, little consideration is given to the allocation of indirect costs (overheads and capital) to hospital services, compared to the allocation of direct costs. Weighted service allocation is believed to provide the most accurate indirect cost estimation, but the method is time consuming. To determine whether hourly rate, inpatient day, and marginal mark-up allocation are reliable alternatives for weighted service allocation. The cost approaches were compared independently for appendectomy, hip replacement, cataract, and stroke in representative general hospitals in The Netherlands for 2005. Hourly rate allocation and inpatient day allocation produce estimates that are not significantly different from weighted service allocation. Hourly rate allocation may be a strong alternative to weighted service allocation for hospital services with a relatively short inpatient stay. The use of inpatient day allocation would likely most closely reflect the indirect cost estimates obtained by the weighted service method.

  19. Calculation and reduction of the sound emissions of overhead power lines

    International Nuclear Information System (INIS)

    Straumann, U.

    2007-01-01

    In this dissertation, Ulrich Straumann of the Swiss Federal Institute of Technology in Zurich, Switzerland, discusses the reduction of sound emissions from overhead power lines. Corona-discharges occur during wet weather or when foggy or icing conditions prevail. Apart from these wide-band crackling noises, low-frequency, tonal emissions also occur. The CONOR (Corona Noise Reduction) project examined these emissions at a frequency of twice the mains frequency and looked for economically feasible solutions to the problems caused by them. The source of these emissions and the mechanisms causing them are discussed. Also, ways of calculating their strength are presented. The effects of varying cable geometry and construction are discussed, as are hydrophilic coatings that could be used to reduce sound emissions.

  20. Interval Analysis Approach to Prototype the Robust Control of the Laboratory Overhead Crane

    Science.gov (United States)

    Smoczek, J.; Szpytko, J.; Hyla, P.

    2014-07-01

    The paper describes the software-hardware equipment and control-measurement solutions elaborated to prototype the laboratory scaled overhead crane control system. The novelty approach to crane dynamic system modelling and fuzzy robust control scheme design is presented. The iterative procedure for designing a fuzzy scheduling control scheme is developed based on the interval analysis of discrete-time closed-loop system characteristic polynomial coefficients in the presence of rope length and mass of a payload variation to select the minimum set of operating points corresponding to the midpoints of membership functions at which the linear controllers are determined through desired poles assignment. The experimental results obtained on the laboratory stand are presented.

  1. Interval Analysis Approach to Prototype the Robust Control of the Laboratory Overhead Crane

    International Nuclear Information System (INIS)

    Smoczek, J; Szpytko, J; Hyla, P

    2014-01-01

    The paper describes the software-hardware equipment and control-measurement solutions elaborated to prototype the laboratory scaled overhead crane control system. The novelty approach to crane dynamic system modelling and fuzzy robust control scheme design is presented. The iterative procedure for designing a fuzzy scheduling control scheme is developed based on the interval analysis of discrete-time closed-loop system characteristic polynomial coefficients in the presence of rope length and mass of a payload variation to select the minimum set of operating points corresponding to the midpoints of membership functions at which the linear controllers are determined through desired poles assignment. The experimental results obtained on the laboratory stand are presented

  2. The Environmental Impact Assessment (EIA) for high-voltage overhead lines; Umweltvertraeglichkeitspruefung (UVP) fuer Hochspannungsfreileitungen

    Energy Technology Data Exchange (ETDEWEB)

    Klockow, S. [Landesentwicklungsgesellschaft Baden-Wuerttemberg, Stuttgart (Germany). Abt. Umwelt

    1996-11-04

    In some of the federal states of Germany the licensing of new or the laying or existing high-voltage overhead lines requires an environmental impact assessment. For many utility companies, however, environmental impact assessments for high-voltage lines are virgin territory. Experience shows that preparing the documentation is not a major problem. Questions usually arise over details such as the calculation of possible incidents or the comparison of different layouts. The authors describes general approaches and strategies and looks at specific problems. (orig.) [Deutsch] Bei der Genehmigung neuer oder der Verlegung vorhandener Hochspannungsfreileitungen ist in einigen Bundeslaendern eine Umweltvertraeglichkeitspruefung durchzufuehren. Fuer viele Energieversorgungsunternehmen ist die Erarbeitung von Umweltvertraeglichkeitsstudien fuer Hochspannungsleitungen aber noch Neuland. Praxiserfahrungen zeigen, dass die Erarbeitung der erforderlichen Unterlagen ohne groessere Schwierigkeiten moeglich ist. Fragen ergeben sich dabei aber bei speziellen Details, z.B. bei der Betrachtung von moeglichen Stoerfaellen oder beim Vergleich von Trassenvarianten. Der Verfasser skizziert das allgemeine Vorgehen und erlaeutert ausfuehrlich die Detailprobleme. (orig.)

  3. Quality control of a kV cone beam computed tomography imaging system

    International Nuclear Information System (INIS)

    Marguet, M.; Bodez, V.

    2009-01-01

    Purpose: This work presents the introduction of a quality assurance program for the On-Board Imager (O.B.I., Varian) kV cone beam computed tomography (kV C.B.C.T.) system, together with the results of 1 year monthly testing. Materials and methods: Firstly the geometric precision and stability of the equipment and of the associated software were evaluated using the Marker phantom. The coincidence of the accelerator isocenter and the imager isocenter was verified as well as the accuracy of the registration of kV cone beam computed tomography (kV C.B.C.T.) with reference CT images. Then, the kV C.B.C.T. image quality was evaluated using the Catphan 504 phantom and ArtiScan software (Aquilab) for both full-fan (F.F.) and half-fan (H.F.) imaging modes. Results: The kV C.B.C.T. isocenter and image registration with correction of the table position were found to be within a tolerance of 2.0 mm. Concerning the kV C.B.C.T. image quality, image noise and uniformity, the Hounsfield units (HU) stability and linearity, geometric distortion and high contrast resolution were all found to be within the manufacturer's recommendations for both F.F. and H.F. modes. However, the low contrast resolution for the HF mode did not meet the manufacturer's specifications. Conclusion: The quality assurance tests introduced have defined the initial system characteristics and their evolution during a period of 1 year, demonstrating the stability of the O.B.I.. (authors)

  4. Trafficking of Kv2.1 Channels to the Axon Initial Segment by a Novel Nonconventional Secretory Pathway

    DEFF Research Database (Denmark)

    Jensen, Camilla Stampe; Watanabe, Shoji; Stas, Jeroen Ingrid

    2017-01-01

    the localization of Kv2.1 in these two different membrane compartments in cultured rat hippocampal neurons of mixed sex. Our data uncover a unique ability of Kv2.1 channels to use two molecularly distinct trafficking pathways to accomplish this. Somatodendritic Kv2.1 channels are targeted by the conventional...... secretory pathway, whereas axonal Kv2.1 channels are targeted by a nonconventional trafficking pathway independent of the Golgi apparatus. We further identified a new AIS trafficking motif in the C-terminus of Kv2.1, and show that putative phosphorylation sites in this region are critical for the restricted.......SIGNIFICANCE STATEMENT Our study uncovered a novel mechanism that targets the Kv2.1 voltage-gated potassium channel to two distinct trafficking pathways and two distinct subcellular destinations: the somatodendritic plasma membrane and that of the axon initial segment. We also identified a distinct motif, including...

  5. Overvoltages transferred from a network of 220 kV to 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'

    Directory of Open Access Journals (Sweden)

    Vukelja Petar

    2011-01-01

    Full Text Available The paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Bašta'. Analysis of survey results lead to conclusion that transferred overvoltages can endanger 15.65 kV transformer windings and stator winding insulation. It was therefore suggested for the protection of the 15.65 kV isolation to install metal oxide surge arresters at a suitable place between the power generator bus bars and earthing.

  6. Modeling and Simulation of Transient Fault Response at Lillgrund Wind Farm when Subjected to Faults in the Connecting 130 kV Grid

    Energy Technology Data Exchange (ETDEWEB)

    Eliasson, Anders; Isabegovic, Emir

    2009-07-01

    The purpose of this thesis was to investigate what type of faults in the connecting grid should be dimensioning for future wind farms. An investigation of over and under voltages at the main transformer and the turbines inside Lillgrund wind farm was the main goal. The results will be used in the planning stage of future wind farms when performing insulation coordination and determining the protection settings. A model of the Lillgrund wind farm and a part of the connecting 130 kV grid were built in PSCAD/EMTDC. The farm consists of 48 Siemens SWT-2.3-93 2.3 MW wind turbines with full power converters. The turbines were modeled as controllable current sources providing a constant active power output up to the current limit of 1.4 pu. The transmission lines and cables were modeled as frequency dependent (phase) models. The load flows and bus voltages were verified towards a PSS/E model and the transient response was verified towards measuring data from two faults, a line to line fault in the vicinity of Barsebaeck (BBK) and a single line-to-ground fault close to Bunkeflo (BFO) substation. For the simulation, three phase to ground, single line to ground and line to line faults were applied at different locations in the connecting grid and the phase to ground voltages at different buses in the connecting grid and at turbines were studied. These faults were applied for different configurations of the farm. For single line to ground faults, the highest over voltage on a turbine was 1.22 pu (32.87 kV) due to clearing of a fault at BFO (the PCC). For line to line faults, the highest over voltage on a turbine was 1.59 pu (42.83 kV) at the beginning of a fault at KGE one bus away from BFO. Both these cases were when all radials were connected and the turbines ran at full power. The highest over voltage observed at Lillgrund was 1.65 pu (44.45 kV). This over voltage was caused by a three phase to ground fault applied at KGE and occurred at the beginning of the fault and when

  7. Clofazimine inhibits human Kv1.3 potassium channel by perturbing calcium oscillation in T lymphocytes.

    Directory of Open Access Journals (Sweden)

    Yunzhao R Ren

    Full Text Available The Kv1.3 potassium channel plays an essential role in effector memory T cells and has been implicated in several important autoimmune diseases including multiple sclerosis, psoriasis and type 1 diabetes. A number of potent small molecule inhibitors of Kv1.3 channel have been reported, some of which were found to be effective in various animal models of autoimmune diseases. We report herein the identification of clofazimine, a known anti-mycobacterial drug, as a novel inhibitor of human Kv1.3. Clofazimine was initially identified as an inhibitor of intracellular T cell receptor-mediated signaling leading to the transcriptional activation of human interleukin-2 gene in T cells from a screen of the Johns Hopkins Drug Library. A systematic mechanistic deconvolution revealed that clofazimine selectively blocked the Kv1.3 channel activity, perturbing the oscillation frequency of the calcium-release activated calcium channel, which in turn led to the inhibition of the calcineurin-NFAT signaling pathway. These effects of clofazimine provide the first line of experimental evidence in support of a causal relationship between Kv1.3 and calcium oscillation in human T cells. Furthermore, clofazimine was found to be effective in blocking human T cell-mediated skin graft rejection in an animal model in vivo. Together, these results suggest that clofazimine is a promising immunomodulatory drug candidate for treating a variety of autoimmune disorders.

  8. Identification of a functional interaction between Kv4.3 channels and c-Src tyrosine kinase.

    Science.gov (United States)

    Gomes, Pedro; Saito, Tomoaki; Del Corsso, Cris; Alioua, Abderrahmane; Eghbali, Mansoureh; Toro, Ligia; Stefani, Enrico

    2008-10-01

    Voltage-gated K(+) (Kv) channels are key determinants of cardiac and neuronal excitability. A substantial body of evidence has accumulated in support of a role for Src family tyrosine kinases in the regulation of Kv channels. In this study, we examined the possibility that c-Src tyrosine kinase participates in the modulation of the transient voltage-dependent K(+) channel Kv4.3. Supporting a mechanistic link between Kv4.3 and c-Src, confocal microscopy analysis of HEK293 cells stably transfected with Kv4.3 showed high degree of co-localization of the two proteins at the plasma membrane. Our results further demonstrate an association between Kv4.3 and c-Src by co-immunoprecipitation and GST pull-down assays, this interaction being mediated by the SH2 and SH3 domains of c-Src. Furthermore, we show that Kv4.3 is tyrosine phosphorylated under basal conditions. The functional relevance of the observed interaction between Kv4.3 and c-Src was established in patch-clamp experiments, where application of the Src inhibitor PP2 caused a decrease in Kv4.3 peak current amplitude, but not the inactive structural analogue PP3. Conversely, intracellular application of recombinant c-Src kinase or the protein tyrosine phosphatase inhibitor bpV(phen) increased Kv4.3 peak current amplitude. In conclusion, our findings provide evidence that c-Src-induced Kv4.3 channel activation involves their association in a macromolecular complex and suggest a role for c-Src-Kv4.3 pathway in regulating cardiac and neuronal excitability.

  9. Sliceable Transponders for Metro-Access Transmission Links

    DEFF Research Database (Denmark)

    Wagner, Christoph; Madsen, P.; Spolitis, S.

    2015-01-01

    the service provider (OLT - optical line terminal) to the end user (ONU – optical network unit) over an optical distribution network (ODN) via low bandwidth equipment. We show simulation and experimental results for duobinary signaling of 1 Gbit/s and 10 Gbit/s waveforms. The number of slices is adjusted...... to match the lowest analog bandwidth of used electrical devices and scale from 2 slices to 10 slices. Results of experimental transmission show error free signal recovery by using post forward error correction with 7% overhead....

  10. Growth, gas exchange, foliar nitrogen content, and water use of subirrigated and overhead irrigated Populus tremuloides Michx. seedlings

    Science.gov (United States)

    Anthony S. Davis; Matthew M. Aghai; Jeremiah R. Pinto; Kent G. Apostal

    2011-01-01

    Because limitations on water used by container nurseries has become commonplace, nursery growers will have to improve irrigation management. Subirrigation systems may provide an alternative to overhead irrigation systems by mitigating groundwater pollution and excessive water consumption. Seedling growth, gas exchange, leaf nitrogen (N) content, and water use were...

  11. Risk factors for, and prevention of, shoulder injuries in overhead sports: a systematic review with best-evidence synthesis.

    Science.gov (United States)

    Asker, Martin; Brooke, Hannah L; Waldén, Markus; Tranaeus, Ulrika; Johansson, Fredrik; Skillgate, Eva; Holm, Lena W

    2018-03-26

    To assess the evidence for risk factors and prevention measures for shoulder injuries in overhead sports. Systematic review with best-evidence synthesis. Medline (Ovid), PubMed (complementary search), Embase (Elsevier), Cochrane (Wiley), SPORTDiscus (Ebsco) and Web of Science Core Collection (Thomson Reuters), from 1 January 1990 to 15 May 2017. Randomised controlled trials, cohort studies and case-control studies on risk factors or prevention measures for shoulder injuries in overhead sports. The eligible studies were quality assessed using the Scottish Intercollegiate Guidelines Network criteria. Of 4778 studies identified, 38 were eligible for quality review and 17 met the quality criteria to be included in the evidence synthesis. One additional quality study presented a shoulder injury prevention programme. Most studies focused on baseball, lacrosse or volleyball (n=13). The risk factors examined included participation level (competition vs training) (n=10), sex (n=4), biomechanics (n=2) and external workload (n=2). The evidence for all risk factors was limited or conflicting. The effect of the prevention programme within the subgroup of uninjured players at baseline was modest and possibly lacked statistical power. All investigated potential risk factors for shoulder injury in overhead sports had limited evidence, and most were non-modifiable (eg, sex). There is also limited evidence for the effect of shoulder injury prevention measures in overhead sports. CRD42015026850. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Business Activity Monitoring: Real-Time Group Goals and Feedback Using an Overhead Scoreboard in a Distribution Center

    Science.gov (United States)

    Goomas, David T.; Smith, Stuart M.; Ludwig, Timothy D.

    2011-01-01

    Companies operating large industrial settings often find delivering timely and accurate feedback to employees to be one of the toughest challenges they face in implementing performance management programs. In this report, an overhead scoreboard at a retailer's distribution center informed teams of order selectors as to how many tasks were…

  13. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Science.gov (United States)

    2010-07-01

    ... (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH... possibility of operator injury resulting from overhead hazards such as flying and falling objects, and at the... used in construction work (see 29 CFR 1926.1002(b) and (j)). In the case of machines to which 29 CFR...

  14. 77 FR 514 - Notice of Availability of the Record of Decision for the North Steens 230 Kilovolt Transmission...

    Science.gov (United States)

    2012-01-05

    ... subsidiary of Columbia Energy Partners, LLC, filed right-of-way (ROW) applications for ROWs with the BLM and... transmission system near Diamond Junction, Oregon. The ROD approves the BLM-preferred Alternative, now the... Project substation, south of Diamond, Oregon and connect to Harney Electric Cooperative's existing 115-kV...

  15. Monochromated scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Rechberger, W.; Kothleitner, G.; Hofer, F.

    2006-01-01

    Full text: Electron energy-loss spectroscopy (EELS) has developed into an established technique for chemical and structural analysis of thin specimens in the (scanning) transmission electron microscope (S)TEM. The energy resolution in EELS is largely limited by the stability of the high voltage supply, by the resolution of the spectrometer and by the energy spread of the source. To overcome this limitation a Wien filter monochromator was recently introduced with commercially available STEMs, offering the advantage to better resolve EELS fine structures, which contain valuable bonding information. The method of atomic resolution Z-contrast imaging within an STEM, utilizing a high-angle annular dark-field (HAADF) detector can perfectly complement the excellent energy resolution, since EELS spectra can be collected simultaneously. In combination with a monochromator microscope not only high spatial resolution images can be recorded but also high energy resolution EELS spectra are attainable. In this work we investigated the STEM performance of a 200 kV monochromated Tecnai F20 with a high resolution Gatan Imaging Filter (HR-GIF). (author)

  16. Development of Highly Selective Kv1.3-Blocking Peptides Based on the Sea Anemone Peptide ShK

    Directory of Open Access Journals (Sweden)

    Michael W. Pennington

    2015-01-01

    Full Text Available ShK, from the sea anemone Stichodactyla helianthus, is a 35-residue disulfide-rich peptide that blocks the voltage-gated potassium channel Kv1.3 at ca. 10 pM and the related channel Kv1.1 at ca. 16 pM. We developed an analog of this peptide, ShK-186, which is currently in Phase 1b-2a clinical trials for the treatment of autoimmune diseases such as multiple sclerosis and rheumatoid arthritis. While ShK-186 displays a >100-fold improvement in selectivity for Kv1.3 over Kv1.1 compared with ShK, there is considerable interest in developing peptides with an even greater selectivity ratio. In this report, we describe several variants of ShK that incorporate p-phophono-phenylalanine at the N-terminus coupled with internal substitutions at Gln16 and Met21. In addition, we also explored the combinatorial effects of these internal substitutions with an alanine extension at the C-terminus. Their selectivity was determined by patch-clamp electrophysiology on Kv1.3 and Kv1.1 channels stably expressed in mouse fibroblasts. The peptides with an alanine extension blocked Kv1.3 at low pM concentrations and exhibited up to 2250-fold selectivity for Kv1.3 over Kv1.1. Analogs that incorporates p-phosphono-phenylalanine at the N-terminus blocked Kv1.3 with IC50s in the low pM range and did not affect Kv1.1 at concentrations up to 100 nM, displaying a selectivity enhancement of >10,000-fold for Kv1.3 over Kv1.1. Other potentially important Kv channels such as Kv1.4 and Kv1.6 were only partially blocked at 100 nM concentrations of each of the ShK analogs.

  17. Blockade of the voltage-gated potassium channel Kv1.3 inhibits immune responses in vivo.

    Science.gov (United States)

    Koo, G C; Blake, J T; Talento, A; Nguyen, M; Lin, S; Sirotina, A; Shah, K; Mulvany, K; Hora, D; Cunningham, P; Wunderler, D L; McManus, O B; Slaughter, R; Bugianesi, R; Felix, J; Garcia, M; Williamson, J; Kaczorowski, G; Sigal, N H; Springer, M S; Feeney, W

    1997-06-01

    The voltage activated K+ channel (Kv1.3) has recently been identified as the molecule that sets the resting membrane potential of peripheral human T lymphoid cells. In vitro studies indicate that blockage of Kv1.3 inhibits T cell activation, suggesting that Kv1.3 may be a target for immunosuppression. However, despite the in vitro evidence, there has been no in vivo demonstration that blockade of Kv1.3 will attenuate an immune response. The difficulty is due to species differences, as the channel does not set the membrane potential in rodent peripheral T cells. In this study, we show that the channel is present on peripheral T cells of miniswine. Using the peptidyl Kv1.3 inhibitor, margatoxin, we demonstrate that Kv1.3 also regulates the resting membrane potential, and that blockade of Kv1.3 inhibits, in vivo, both a delayed-type hypersensitivity reaction and an Ab response to an allogeneic challenge. In addition, prolonged Kv1.3 blockade causes reduced thymic cellularity and inhibits the thymic development of T cell subsets. These results provide in vivo evidence that Kv1.3 is a novel target for immunomodulation.

  18. The Seismic Analysis of 800kV Gas Insulated Switchgear (GIS) for the Dangjin Thermal Plant

    Energy Technology Data Exchange (ETDEWEB)

    Shin, I.H.; Song, W.P.; Kweon, K.Y. [Hyosung Corporation (Korea)

    1999-05-01

    800kV GIS (Gas Insulated Switchgear) which was first developed in korea at Dec. 1998 and is going to be installed in the dangjin thermal plant. We checked the stability of 800kV GIS under seismic load. pro-ENGINEER and PATRAN were used for modeling exactly 800kV GIS geometry. The 800kV GIS was modeled as shell elements for the enclosures and beam elements for the conductors and the support insulators. (author). 2 refs., 9 figs., 2 tabs.

  19. Eccentric and isometric shoulder rotator cuff strength testing using a hand-held dynamometer: reference values for overhead athletes.

    Science.gov (United States)

    Cools, Ann M J; Vanderstukken, Fran; Vereecken, Frédéric; Duprez, Mattias; Heyman, Karel; Goethals, Nick; Johansson, Fredrik

    2016-12-01

    In order to provide science-based guidelines for injury prevention or return to play, regular measurement of isometric and eccentric internal (IR) and external (ER) rotator strength is warranted in overhead athletes. However, up to date, no normative database exists regarding these values, when measured with a hand-held dynamometer. Therefore, the purpose of the study was to provide a normative database on isometric and eccentric rotator cuff (RC) strength values in a sample of overhead athletes, and to discuss gender, age and sports differences. A HHD was used to measure RC strength in 201 overhead athletes between 18 and 50 years old from three different sports disciplines: tennis, volleyball and handball. Isometric as well as eccentric strength was measured in different shoulder positions. Outcome variables of interest were isometric ER and IR strength, eccentric ER strength, and intermuscular strength ratios ER/IR. Our results show significant side, gender and sports discipline differences in the isometric and eccentric RC strength. However, when normalized to body weight, gender differences often are absent. In general, strength differences are in favour of the dominant side, the male athletes and handball. Intermuscular ER/IR ratios showed gender, sports, and side differences. This normative database is necessary to help the clinician in the evaluation of RC strength in healthy and injured overhead athletes. In view of the preventive screening and return-to-play decisions in overhead athletes, normalization to body weight and calculating intermuscular ratios are key points in this evaluation. Diagnostic study, Level III.

  20. 600 kV modulator design for the SLAC Next Linear Collider Test Accelerator

    International Nuclear Information System (INIS)

    Harris, K.; de Lamare, J.; Nesterov, V.; Cassel, R.

    1992-07-01

    Preliminary design for the SLAC Next Linear Collider Test Accelerator (NLCTA) requires a pulse power source to produce a 600 kV, 600 A, 1.4 μs, 0.1% flat top pulse with rise and fall times of approximately 100 ns to power an X-Band klystron with a microperveance of 1.25 at ∼ 100 MW peak RF power. The design goals for the modulator, including those previously listed, are peak modulator pulse power of 340 MW operating at 120 Hz. A three-stage darlington pulse-forming network, which produces a >100 kV, 1.4 μs pulse, is coupled to the klystron load through a 6:1 pulse transformer. Careful consideration of the transformer leakage inductance, klystron capacitance, system layout, and component choice is necessary to produce the very fast rise and fall times at 600 kV operating continuously at 120 Hz

  1. Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison

    International Nuclear Information System (INIS)

    Kelley, Nathan; Corsaro, Pietro

    2004-01-01

    Customer acceptance of high temperature superconducting (HTS) cable technology requires a substantial field demonstration illustrating both the system's technical capabilities and its suitability for installation and operation within the utility environment. In this project, the world's first underground installation of an HTS cable using existing ductwork, a 120 meter demonstration cable circuit was designed and installed between the 24 kV bus distribution bus and a 120 kV-24 kV transformer at Detroit Edison's Frisbie substation. The system incorporated cables, accessories, a refrigeration system, and control instrumentation. Although the system was never put in operation because of problems with leaks in the cryostat, the project significantly advanced the state-of-the-art in the design and implementation of Warm Dielectric cable systems in substation applications. Lessons learned in this project are already being incorporated in several ongoing demonstration projects

  2. Rearrangement of potassium ions and Kv1.1/Kv1.2 potassium channels in regenerating axons following end-to-end neurorrhaphy: ionic images from TOF-SIMS.

    Science.gov (United States)

    Liu, Chiung-Hui; Chang, Hung-Ming; Wu, Tsung-Huan; Chen, Li-You; Yang, Yin-Shuo; Tseng, To-Jung; Liao, Wen-Chieh

    2017-10-01

    The voltage-gated potassium channels Kv1.1 and Kv1.2 that cluster at juxtaparanodal (JXP) regions are essential in the regulation of nerve excitability and play a critical role in axonal conduction. When demyelination occurs, Kv1.1/Kv1.2 activity increases, suppressing the membrane potential nearly to the equilibrium potential of K + , which results in an axonal conduction blockade. The recovery of K + -dependent communication signals and proper clustering of Kv1.1/Kv1.2 channels at JXP regions may directly reflect nerve regeneration following peripheral nerve injury. However, little is known about potassium channel expression and its relationship with the dynamic potassium ion distribution at the node of Ranvier during the regenerative process of peripheral nerve injury (PNI). In the present study, end-to-end neurorrhaphy (EEN) was performed using an in vivo model of PNI. The distribution of K + at regenerating axons following EEN was detected by time-of-flight secondary-ion mass spectrometry. The specific localization and expression of Kv1.1/Kv1.2 channels were examined by confocal microscopy and western blotting. Our data showed that the re-establishment of K + distribution and intensity was correlated with the functional recovery of compound muscle action potential morphology in EEN rats. Furthermore, the re-clustering of Kv1.1/1.2 channels 1 and 3 months after EEN at the nodal region of the regenerating nerve corresponded to changes in the K + distribution. This study provided direct evidence of K + distribution in regenerating axons for the first time. We proposed that the Kv1.1/Kv1.2 channels re-clustered at the JXP regions of regenerating axons are essential for modulating the proper patterns of K + distribution in axons for maintaining membrane potential stability after EEN.

  3. In vitro measurement of CT density and estimation of stenosis related to coronary soft plaque at 100 kV and 120 kV on ECG-triggered scan

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun, E-mail: horiguch@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Fujioka, Chikako, E-mail: fujioka@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Kiguchi, Masao, E-mail: kiguchi@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Yamamoto, Hideya, E-mail: hideyayama@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Shen, Yun, E-mail: Yuna.Shen@ge.com [CT Lab of Great China, GE Healthcare, L12 and L15, Office Tower, Langham Place, 8 Argyle Street, Mongkok Kowloon (Hong Kong); Kihara, Yasuki, E-mail: ykihara@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan)

    2011-02-15

    Purpose: The purpose of the study was to compare 100 kV and 120 kV prospective electrocardiograph (ECG)-triggered axial coronary 64-detector CT angiography (64-MDCTA) in soft plaque diagnosis. Materials and methods: Coronary artery models (n = 5) with artificial soft plaques (-32 HU to 53 HU at 120 kV) with three stenosis levels (25%, 50% and 75%) on a cardiac phantom (mimicking slim patient's environment) were scanned in heart rates of 55, 60 and 65 beats per minute (bpm). Four kinds of intracoronary enhancement (205 HU, 241 HU, 280 HU and 314 HU) were simulated. The soft plaque density and the measurement error of stenosis (in percentage), evaluated by two independent observers, were compared between 100 kV and 120 kV. The radiation dose was estimated. Results: Interobserver correlation of the measurement was excellent (density; r = 0.95 and stenosis measure; r = 0.97). Neither the density of soft plaque nor the measurement error of stenosis was different between 100 kV and 120 kV (p = 0.22 and 0.08). The estimated radiation doses were 2.0 mSv and 3.3 mSv (in 14 cm coverage) on 100 kV and 120 kV prospective ECG-triggered axial scans, respectively. Conclusion: The 100 kV prospective ECG-triggered coronary MDCTA has comparable performance to 120 kV coronary CTA in terms of soft plaque densitometry and measurement of stenosis, with a reduced effective dose of 2 mSv.

  4. Improvement the Capacity of Cockcroft-Walton High Voltage Source from 300 kV/20 mA to 500 kV/20 mA for Accelerating Voltage of Electron Beam Machine

    International Nuclear Information System (INIS)

    Suprapto; Djasiman

    2002-01-01

    The improvement capacity of Cockcroft-Walton high voltage source from 300 kV/20 mA to 500 kV/mA has been carrying out. To improve the capacity of high voltage source was done by means of increasing the stage number of voltage multiplier from 11 to 18 and its output voltage measuring resistance. Each stage of voltage multiplier consists of 2 capacitors and 2 circuits of high voltage diode. This voltage multiplier is constructed using main components of high voltage capacitor and high voltage diode each of 0.22 μF/50 kV and UF 5408 respectively. To avoid stray discharge and corona it was provided with high voltage electrode and corona ring. The test result indicated that the output voltage obtained from 16 stages was 350 kV according to operating condition of 25 MΩ resistive load and first stage voltage of 28.5 kV with oscillator frequency of 24 Hz. That condition requires anode voltage and current of 5.5 kV and 2.5 A respectively. The no load test for 16 stages indicates 400 kV of output voltage and 28.5 kV first stage voltage. Efficiency of high voltage source was 48 % at 6.75 kW of output power. The expected test of 500 kV with 18 stages of voltage multiplier can not be carried out because of some restrictive of loading system. From the test result can be predicted that the output voltage of 500 kV with 18 stages of voltage multiplier requires 31.2 kV of first stage voltage. Then the expected high voltage source of Cockcroft-Walton is capable as accelerating voltage source for Electron Beam Machine with energy of 500 kV. (author)

  5. Dynamics and Embedded Internet of Things Input Shaping Control for Overhead Cranes Transporting Multibody Payloads

    Directory of Open Access Journals (Sweden)

    Gerardo Peláez

    2018-06-01

    Full Text Available Input shaping is an Optimal Control feedforward strategy whose ability to define how and when a flexible dynamical system defined by Ordinary Differential Equations (ODEs and computer controlled would move into its operative space, without command induced unwanted dynamics, has been exhaustively demonstrated. This work examines the issue of Embedded Internet of Things (IoT Input Shaping with regard to real time control of multibody oscillatory systems whose dynamics are better described by differential algebraic equations (DAEs. An overhead crane hanging a double link multibody payload has been appointed as a benchmark case; it is a multibody, multimode system. This might be worst scenario to implement Input Shaping. The reasons can be found in the wide array of constraints that arise. Firstly, the reliability of the multibody model was tested on a Functional Mock-Up Interface (FMI with the two link payload suspended from the trolley by comparing the experimental video tapping signals in time domain faced with the signals extracted from the multibody model. The FFTs of the simulated and the experimental signal contain the same frequency harmonics only with somewhat different power due to the real world light damping in the joints. The application of this approach may be extended to other cases i.e., the usefulness of mobile hydraulic cranes is limited because the payload is supported by an overhead cable under tension that allows oscillation to occur during crane motion. If the payload size is not negligible small when compared with the cable length may introduce an additional oscillatory mode that creates a multibody double pendulum. To give the insight into the double pendulum dynamics by Lagrangian methods two slender rods as payloads are analyzed dealing with the overhead crane and a composite revolute-revolute joint is proposed to model the cable of the hydraulic crane, both assumptions facilitates an affordable analysis. This allows

  6. Dynamics and Embedded Internet of Things Input Shaping Control for Overhead Cranes Transporting Multibody Payloads.

    Science.gov (United States)

    Peláez, Gerardo; Vaugan, Joshua; Izquierdo, Pablo; Rubio, Higinio; García-Prada, Juan Carlos

    2018-06-04

    Input shaping is an Optimal Control feedforward strategy whose ability to define how and when a flexible dynamical system defined by Ordinary Differential Equations (ODEs) and computer controlled would move into its operative space, without command induced unwanted dynamics, has been exhaustively demonstrated. This work examines the issue of Embedded Internet of Things (IoT) Input Shaping with regard to real time control of multibody oscillatory systems whose dynamics are better described by differential algebraic equations (DAEs). An overhead crane hanging a double link multibody payload has been appointed as a benchmark case; it is a multibody, multimode system. This might be worst scenario to implement Input Shaping. The reasons can be found in the wide array of constraints that arise. Firstly, the reliability of the multibody model was tested on a Functional Mock-Up Interface (FMI) with the two link payload suspended from the trolley by comparing the experimental video tapping signals in time domain faced with the signals extracted from the multibody model. The FFTs of the simulated and the experimental signal contain the same frequency harmonics only with somewhat different power due to the real world light damping in the joints. The application of this approach may be extended to other cases i.e., the usefulness of mobile hydraulic cranes is limited because the payload is supported by an overhead cable under tension that allows oscillation to occur during crane motion. If the payload size is not negligible small when compared with the cable length may introduce an additional oscillatory mode that creates a multibody double pendulum. To give the insight into the double pendulum dynamics by Lagrangian methods two slender rods as payloads are analyzed dealing with the overhead crane and a composite revolute-revolute joint is proposed to model the cable of the hydraulic crane, both assumptions facilitates an affordable analysis. This allows developing a general

  7. The 100 kV Faraday cage (High Voltage Deck) for the SPIDER experiment

    International Nuclear Information System (INIS)

    Boldrin, Marco; Grando, Luca; Pesce, Alberto; Recchia, Mauro; Toigo, Vanni; Gutierrez, Daniel; Simon, Muriel; Faoro, Giovanni; Guion, Andrea; Maggiora, Edoardo; Pedron, Diego; Roman, Anita; Decamps, Hans

    2015-01-01

    Highlights: • A 100 keV experiment is under construction to optimize ITER NBI Ion Source. • The Ion Source Power Supplies are hosted inside a wide −100 kVdc Faraday cage (HVD). • The paper reports on the design solutions of the HVD. • Electrostatic and electromagnetic analyses are presented. • Procurement activities status is reported. - Abstract: In order to optimize the design and operation of the Ion Source for the ITER Neutral Beam Injector (NBI), a dedicated 100 keV Ion Source, identified as Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER), is under construction in the Neutral Beam Test Facility, at the Consorzio RFX premises, in Padua, Italy. The Ion Source, polarized at −112 kVdc voltage, will produce negative ions (Deuterium D"− or Hydrogen H"−) which, extracted from the Plasma Grid with an extraction voltage up to 12 keV, are accelerated up to 100 keV by the 100 kVdc Power Supply (100 kV PS). The required Ion Source and the Extraction Power Supplies (ISEPS) system and the associated diagnostics are hosted inside a High Voltage Deck (HVD), a −100 kVdc air-insulated Faraday cage. These power supplies and various diagnostics and control equipment are connected to the Ion Source by means of a High Voltage Transmission Line (TL). The HVD (procurement started mid 2013; delivery on site in the second half of 2014) will consist of a wide structure (13 m (L) × 11 m (W) × 5 m (H)), designed to support the weight of the ISEPS components, mounted on supporting insulators and clad with a conductive metal sheet in order to reduce the electromagnetic interference (EMI). The paper reports on the design solutions of the HVD focusing on insulation, mechanical, thermal and EMI issues. The details of the main HVD interfaces with the TL and with insulating transformer are also described. Finite Element (FE) analyses have been performed, on the one hand, to verify the configuration from the electrostatic point of view and

  8. The 100 kV Faraday cage (High Voltage Deck) for the SPIDER experiment

    Energy Technology Data Exchange (ETDEWEB)

    Boldrin, Marco, E-mail: marco.boldrin@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Grando, Luca; Pesce, Alberto; Recchia, Mauro; Toigo, Vanni [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Corso Stati Uniti 4, 35127 Padova (Italy); Gutierrez, Daniel; Simon, Muriel [Fusion for Energy, c/o Josep Pla 2, 08019 Barcelona (Spain); Faoro, Giovanni; Guion, Andrea; Maggiora, Edoardo; Pedron, Diego [COELME – Costruzioni Elettromeccaniche S.p.A., via G. Galilei no. 1/2, 30036 S. Maria di Sala, Venezia (Italy); Roman, Anita [Studio di Ingegneria RS s.r.l., Viale dell’Arcella 1, 35153 Padova (Italy); Decamps, Hans [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • A 100 keV experiment is under construction to optimize ITER NBI Ion Source. • The Ion Source Power Supplies are hosted inside a wide −100 kVdc Faraday cage (HVD). • The paper reports on the design solutions of the HVD. • Electrostatic and electromagnetic analyses are presented. • Procurement activities status is reported. - Abstract: In order to optimize the design and operation of the Ion Source for the ITER Neutral Beam Injector (NBI), a dedicated 100 keV Ion Source, identified as Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER), is under construction in the Neutral Beam Test Facility, at the Consorzio RFX premises, in Padua, Italy. The Ion Source, polarized at −112 kVdc voltage, will produce negative ions (Deuterium D{sup −} or Hydrogen H{sup −}) which, extracted from the Plasma Grid with an extraction voltage up to 12 keV, are accelerated up to 100 keV by the 100 kVdc Power Supply (100 kV PS). The required Ion Source and the Extraction Power Supplies (ISEPS) system and the associated diagnostics are hosted inside a High Voltage Deck (HVD), a −100 kVdc air-insulated Faraday cage. These power supplies and various diagnostics and control equipment are connected to the Ion Source by means of a High Voltage Transmission Line (TL). The HVD (procurement started mid 2013; delivery on site in the second half of 2014) will consist of a wide structure (13 m (L) × 11 m (W) × 5 m (H)), designed to support the weight of the ISEPS components, mounted on supporting insulators and clad with a conductive metal sheet in order to reduce the electromagnetic interference (EMI). The paper reports on the design solutions of the HVD focusing on insulation, mechanical, thermal and EMI issues. The details of the main HVD interfaces with the TL and with insulating transformer are also described. Finite Element (FE) analyses have been performed, on the one hand, to verify the configuration from the electrostatic point of

  9. Evaluation of variation of voltage (kV) absorbed dose in chest CT scans

    International Nuclear Information System (INIS)

    Mendonca, Bruna G.A.; Mourao, Arnaldo P.

    2013-01-01

    Computed tomography (CT) is one of the most important diagnostic techniques images today. The increasing utilization of CT implies a significant increase of population exposure to ionizing radiation. Optimization of practice aims to reduce doses to patients because the image quality is directly related to the diagnosis. You can decrease the amount of dose to the patient, and maintain the quality of the image. There are several parameters that can be manipulated in a CT scan and these parameters can be used to reduce the energy deposited in the patient. Based on this, we analyzed the variation of dose deposited in the lungs, breasts and thyroid, by varying the supply voltage of the tube. Scans of the thorax were performed following the protocol of routine chest with constant and variable current for the same applied voltage. Moreover, a female phantom was used and thermoluminescent dosimeters (TLD-100), model bat, were used to record the specific organ doses. Scans were performed on a GE CT scanner, model 64 Discovery channels. Higher doses were recorded for the voltage of 120 kV with 200 mAs in the lungs (22.46 mGy) and thyroid (32.22 mGy). For scans with automatic mAs, variable between 100 and 440, this same tension contributed to the higher doses. The best examination in terms of the dose that was used with automatic 80 kV mAs, whose lungs and thyroid received lower dose. For the best breast exam was 100 kV. Since the increase in the 80 kV to 100 kV no impact so much the dose deposited in the lungs, it can be concluded that lowering the applied voltage to 100 kV resulted in a reduction in the dose absorbed by the patient. These results can contribute to optimizing scans of the chest computed tomography

  10. Transmission investment problems in Europe: Going beyond standard solutions

    International Nuclear Information System (INIS)

    Buijs, Patrik; Bekaert, David; Cole, Stijn; Van Hertem, Dirk; Belmans, Ronnie

    2011-01-01

    The European transmission grid is facing an investment challenge. There is a strong call for more transmission capacity. At the same time, the investment climate is fierce and troubled by public opposition, a complex regulatory framework, etc. Many transmission capacity expansion projects are delayed or canceled. In this paper different technology options suitable for increasing transmission capacity are discussed. The aim is to provide policy-makers with information on technologies without going too much into technical details. The focus is on opportunities and limitations to implement various technological alternatives in practice, including technical solutions that go beyond constructing new connection lines. The criteria used in this technology assessment are based on the obstacles reported in the European Priority Interconnection Plan. This ensures a realistic approach based on problems encountered in real projects. Although AC overhead lines (OHL) will remain the standard solution for grid expansion, it is argued that different technology options can overcome many obstacles that OHL face. Additionally, it is illustrated that the higher investment costs for some solutions can be offset with an increased benefit, e.g. by accomplishing investments with smaller delays due to fewer obstacles encountered. - Research highlights: → Assessment of real problems encountered in transmission investments. → Comparison of transmission technologies. → Techno-economic evaluation of transmission technologies.

  11. STUDY OF TRANSMISSION LINES EFFECT ON THE SYSTEM OPERATIONON OF CONTINUOUS AUTOMATIC CAB SIGNALLING

    Directory of Open Access Journals (Sweden)

    O. O. Hololobova

    2014-10-01

    Full Text Available Purpose. To conduct an effect research of the electromagnetic field of high-voltage transmission lines (HVTL (750 kV, 50 Hz on the track circuits and continuous automatic cab signalling (CACS with a signal current of 50 Hz in the areas of convergence and intersection with the transmission lines and to propose possible methods to improve noise immunity of CACS. Methodology. The measurements were performed both by means of car-laboratory and directly on rail lines. During the study the electric field strength in the range of industrial frequency directly under the transmission lines and at the distance from it to the railway lines was measured, as well as the time dependence of CACS codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and its passing. Findings. The root causes analysis of CACS faults and failures was carried out. The effect of the electromagnetic field of high-voltage transmission lines (750 kV, 50 Hz on the track circuit and CACS with signal current of 50 Hz in the areas of convergence and intersection with the transmission line was investigated. Possible methods to improve noise immunity of CACS were considered. Originality. The effect research of transmission lines (750 kV on the operation of the automatic cab signalling on spans Prishib-Burchatsk and Privolnoye-Yelizarovo, Pridneprovsk railway in places of oblique railroads crossing and transmission lines (750 kV, 50 Hz was conducted. Electric field strength in the range of industrial frequency directly under the transmission lines and at a distance from it to the railway line, as well as the time dependences of ALSN codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and as its passing were measured. It was found that CACS codes in track circuits under transmission lines are strongly distorted, as strength

  12. Use of FACTS for enhanced flexibility and efficiency in power transmission and distribution grids

    Energy Technology Data Exchange (ETDEWEB)

    Grunbaum, Rolf; Wahlberg, Conny; Sannino, Ambra

    2010-09-15

    The paper shows how the use of FACTS increases flexibility in power transmission and distribution, improving capacity of transmission corridors to integrate renewable power production. Examples included are 69 kV directly connected SVCs for grid stabilization in conjunction with a high degree of wind power penetration; series compensation to evacuate power from the largest wind power installation in USA; SVC to increase the reliability and reduce congestion over a heavily loaded power corridor; thyristor controlled series compensation to increase the dynamic stability and power transmission capability of a power inter-connector. Finally, some applications of Dynamic energy storage are highlighted.

  13. Switching Overvoltages in 60 kV reactor compensated cable grid due to resonance after disconnection

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Baldursson, Haukur; Oumarou, Abdoul M.

    2008-01-01

    power could be directly connected to long cables. Switching both cable and reactor together will cause resonance to occur between the cable capacitance and the inductance of the cable during last end disconnection. Similar type of resonance condition is known to have caused switching overvoltages...... on the 400kV grid in Denmark. Therefore it is considered necessary to analyze further whether connecting a reactor directly to 60kV cable can cause switching overvoltages. A model in PSCAD was used to analyze which parameters can cause overvoltage. The switching resonance overvoltage was found to be caused...

  14. Performance of a 100-kV, 78-kJ electric-gun system

    International Nuclear Information System (INIS)

    Chau, H.; Dittbenner, G.; Mikkelsen, K.; Weingart, R.; Froeschner, K.; Lee, R.

    1981-01-01

    A new electric gun system was constructed for use in high-pressure EOS studies. The system is powered by a 100 kV, 15.6 μF capacitor bank. At 100 kV charging voltage the system inductance is 23 nH. This system has driven 0.3 mm-thick Kapton projectiles to > 20 km/s and 0.3 mm Kapton/30 μm Ta projectiles to approx. 10 km/s. Projectile velocity is modeled phenomenlogically by an electrical Gurney model

  15. High power cable with internal water cooling 400 kV

    Energy Technology Data Exchange (ETDEWEB)

    Rasquin, W; Harjes, B

    1982-08-01

    The project was planned for a duration of 4 years. Afterwards it has been extended over 6 years and finally stopped after 3 1/2 years. Therefore, of course results of field tests with an internally cooled 400 kV cable are not available. Nevertheless, this conductor cooled high power cable has been developed to such an extend, that this manufactured cable could withstand type tests according to IEC/VDE recommendations. Even by missing field tests it is obvious that a high power cable for 400 kV is available.

  16. Short-Circuit Degradation of 10-kV 10-A SiC MOSFET

    DEFF Research Database (Denmark)

    Eni, Emanuel-Petre; Beczkowski, Szymon; Munk-Nielsen, Stig

    2017-01-01

    The short-circuit behavior of power devices is highly relevant for converter design and fault protection. In this work, the degradation during short-circuit of a 10 kV 10 A 4H-SiC MOSFET is investigated at 6 kV DC-link voltage. The study aims to present the behavior of the device during short-circuit...... transients as it sustains increasing short-circuit pulses during its life-time. As the short-circuit pulse length increases, degradation of the device can be observed in periodically performed characterizations. The initial degradation seems to be associated with the channel region, and continuous stressing...

  17. Trafficking and intracellular regulation of Kv7.1 potassium channels in the heart

    DEFF Research Database (Denmark)

    Nielsen, Nathalie Hélix

    identified. About 100 of these mutations are located in the N- or the C-terminal parts of the channel. The aim of the present work was to gain a better understanding of the Kv7.1 channel protein function. In the first study we identified a Kv7.1 missense mutation in a German family with Long QT Syndrome......The electrical activity of the heart, measured by application of surface body electrodes and recorded as an electrocardiogram, is the result of a finely tuned balance of ion movement (K+, Na+, Ca2+). The ionic currents collectively constitute the cardiac action potential created in the cell...

  18. AMP-activated protein kinase downregulates Kv7.1 cell surface expression

    DEFF Research Database (Denmark)

    Andersen, Martin N; Krzystanek, Katarzyna; Jespersen, Thomas

    2012-01-01

    in response to polarization of the epithelial Madin-Darby canine kidney (MDCK) cell line and that this was mediated by activation of protein kinase C (PKC). In this study, the pathway downstream of PKC, which leads to internalization of Kv7.1 upon cell polarization, is elucidated. We show by confocal...... microscopy that Kv7.1 is endocytosed upon initiation of the polarization process and sent for degradation by the lysosomal pathway. The internalization could be mimicked by pharmacological activation of the AMP-activated protein kinase (AMPK) using three different AMPK activators. We demonstrate...

  19. Fiber Bragg Grating Sensor for Fault Detection in Radial and Network Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mehdi Shadaram

    2010-10-01

    Full Text Available In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG. The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system.

  20. A truncated Kv1.1 protein in the brain of the megencephaly mouse: expression and interaction

    Directory of Open Access Journals (Sweden)

    Århem Peter

    2005-11-01

    Full Text Available Abstract Background The megencephaly mouse, mceph/mceph, is epileptic and displays a dramatically increased brain volume and neuronal count. The responsible mutation was recently revealed to be an eleven base pair deletion, leading to a frame shift, in the gene encoding the potassium channel Kv1.1. The predicted MCEPH protein is truncated at amino acid 230 out of 495. Truncated proteins are usually not expressed since nonsense mRNAs are most often degraded. However, high Kv1.1 mRNA levels in mceph/mceph brain indicated that it escaped this control mechanism. Therefore, we hypothesized that the truncated Kv1.1 would be expressed and dysregulate other Kv1 subunits in the mceph/mceph mice. Results We found that the MCEPH protein is expressed in the brain of mceph/mceph mice. MCEPH was found to lack mature (Golgi glycosylation, but to be core glycosylated and trapped in the endoplasmic reticulum (ER. Interactions between MCEPH and other Kv1 subunits were studied in cell culture, Xenopus oocytes and the brain. MCEPH can form tetramers with Kv1.1 in cell culture and has a dominant negative effect on Kv1.2 and Kv1.3 currents in oocytes. However, it does not retain Kv1.2 in the ER of neurons. Conclusion The megencephaly mice express a truncated Kv1.1 in the brain, and constitute a unique tool to study Kv1.1 trafficking relevant for understanding epilepsy, ataxia and pathologic brain overgrowth.

  1. Chronic electroconvulsive stimulation but not chronic restraint stress modulates mRNA expression of voltage-dependent potassium channels Kv7.2 and Kv11.1 in the rat piriform cortex

    DEFF Research Database (Denmark)

    Hjæresen, Marie-Louise; Hageman, Ida; Wörtwein, Gitta

    2008-01-01

    The mechanisms by which stress and electroconvulsive therapy exert opposite effects on the course of major depression are not known. Potential candidates might include the voltage-dependent potassium channels. Potassium channels play an important role in maintaining the resting membrane potential...... and controlling neuronal excitability. To explore this hypothesis, we examined the effects of one or several electroconvulsive stimulations and chronic restraint stress (6 h/day for 21 days) on the expression of voltage-dependent potassium channel Kv7.2, Kv11.1, and Kv11.3 mRNA in the rat brain using in situ...... hybridization. Repeated, but not acute, electroconvulsive stimulation increased Kv7.2 and Kv11.1 mRNA levels in the piriform cortex. In contrast, restraint stress had no significant effect on mRNA expression of Kv7.2, Kv11.1, or Kv11.3 in any of the brain regions examined. Thus, it appears that the investigated...

  2. Transmission line component testing for the ITER Ion Cyclotron Heating and Current Drive System

    Science.gov (United States)

    Goulding, Richard; Bell, G. L.; Deibele, C. E.; McCarthy, M. P.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Barbier, C. N.; Cambell, I. H.; Moon, R. L.; Pesavento, P. V.; Fredd, E.; Greenough, N.; Kung, C.

    2014-10-01

    High power RF testing is underway to evaluate transmission line components for the ITER Ion Cyclotron Heating and Current Drive System. The transmission line has a characteristic impedance Z0 = 50 Ω and a nominal outer diameter of 305 mm. It is specified to carry up to 6 MW at VSWR = 1.5 for 3600 s pulses, with transient voltages up to 40 kV. The transmission line is actively cooled, with turbulent gas flow (N2) used to transfer heat from the inner to outer conductor, which is water cooled. High voltage and high current testing of components has been performed using resonant lines generating steady state voltages of 35 kV and transient voltages up to 60 kV. A resonant ring, which has operated with circulating power of 6 MW for 1 hr pulses, is being used to test high power, low VSWR operation. Components tested to date include gas barriers, straight sections of various lengths, and 90 degree elbows. Designs tested include gas barriers fabricated from quartz and aluminum nitride, and transmission lines with quartz and alumina inner conductor supports. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  3. Electric power transmission for a Hanford Nuclear Energy Center (HNEC)

    International Nuclear Information System (INIS)

    Harty, H.; Dowis, W.J.

    1983-06-01

    The original study of transmission for a Hanford Nuclear Energy Center (HNEC), which was completed in September 1975, was updated in June 1978. The present 1983 revision takes cognizance of recent changes in the electric power situation of the PNW with respect to: (1) forecasts of load growth, (2) the feasibility of early use of 1100 kV transmission, and (3) the narrowing opportunities for siting nuclear plants in the region. The purpose of this update is to explore and describe additions to the existing transmission system that would be necessary to accommodate three levels of generation at HNEC. Comparisons with a PNW system having new thermal generating capacity distributed throughout the marketing region are not made as was done in earlier versions

  4. The Transmission Line for the SPIDER experiment

    International Nuclear Information System (INIS)

    Boldrin, Marco; De Lorenzi, Antonio; Recchia, Mauro; Toigo, Vanni; Bonicelli, Tullio; Simon, Muriel

    2011-01-01

    The 100 keV Ion Source Test facility - Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER) - is aimed to test the full scale prototype of the Ion Source for the ITER 1 MeV Neutral Beam Injector (NBI). The SPIDER facility requires the construction of a High Voltage Deck (HVD) and of a High Voltage Transmission Line (TL) respectively to host the Ion Source Power Supplies system polarized at 100 kV and to carry the power and signal conductors to the beam accelerator. In already existing NBI systems with beam energy above 100 keV, the TL is realized with the SF 6 Gas Insulated Line technology. In the SPIDER TL case, the presence of a large inner conductor (half meter diameter), would make the pressurized TL a complex and costly component; therefore a free air insulated solution has been proposed. The paper focuses on the design of this TL, which has to host inside the complex high potential (100 kV) inner electrode a number of power and measuring conductors and has to minimize the Electro Magnetic Interferences (EMI) produced by the frequent grids breakdowns. Finite Element (FE) analyses have been performed to verify the configuration from the electrostatic point of view, to evaluate EMI screening effectiveness and to assess the impact of the relatively high thermal dissipation of power conductors located inside the high potential electrode. Moreover, an experimental test campaign has been carried out on a TL mockup to validate the TL electrostatic configuration under DC voltage. Finally, the paper reports on the status of procurement activities for the Transmission Line.

  5. 76 FR 19744 - Final Tropic to Hatch 138 kV Transmission Line Project Environmental Impact Statement and...

    Science.gov (United States)

    2011-04-08

    ... area currently designated as Primitive Zone in the Monument Management Plan, and (b) changing the... information--may be made publicly available at any time. While you can ask us in your protest to withhold your...

  6. 75 FR 32357 - Gallatin National Forest; Montana; Jack Rabbit to Big Sky Meadow Village 161 kV Transmission Line...

    Science.gov (United States)

    2010-06-08

    ... prior to the close of the comment period and should clearly articulate the reviewer's concerns and... during the scoping of the proposed action and the comment period. The decision maker will take into... near Cascade Creek homes/Lava Lake Trailhead area, Greek Creek homes and the Deer Creek Trailhead areas...

  7. 75 FR 3486 - Susquehanna to Roseland 500kV Transmission Line, Environmental Impact Statement, Delaware Water...

    Science.gov (United States)

    2010-01-21

    ... violations, starting in 2012 and beyond, that the proposed project is designed to alleviate. The Federal... Comment (PEPC) website at http://parkplanning.nps.gov/dewa/ . Dates and Meeting Notices: The public... public an opportunity to review the proposal and project information. All public meetings will be...

  8. Design of an overhead crane for the ITER NB cell remote handling maintenance operations

    Energy Technology Data Exchange (ETDEWEB)

    Taubmann, Gonzalo; Brochet, Laurent [IBERTEF A.I.E., Iberica de Tecnologia de Fusion, C/Magallanes 3, 28015 Madrid (Spain); Liniers, Macarena [Asociacion EURATOM-CIEMAT para la Fusion, Av. Complutense 22, 28040 Madrid (Spain)], E-mail: macarena.liniers@ciemat.es; Medrano, Mercedes; Sarasola, Xabier; Botija, Jose; Alonso, Javier [Asociacion EURATOM-CIEMAT para la Fusion, Av. Complutense 22, 28040 Madrid (Spain); Damiani, Carlo [FUSION FOR ENERGY, Josep Pla 2, Torres Diagonal Litoral Ed B3, 08019 Barcelona (Spain)

    2009-06-15

    In the neutral beam cell of ITER all the maintenance operations on the neutral beam components (BLC's) must be performed by an overhead crane of large payload capability (30-50 tonnes). A crane system is presented consisting of a monorail, a carriage, and a lifting mechanism. The monorail must give access to the BLC's in the beam line vessel, the front components connecting the NB vessel with the Tokamak, and a storage area at the north end of the NB cell. Rail switching points are required at the intersections between radial and toroidal branches. A translational switching mechanism is proposed. The crane carriage consists of two independent sub-carriages, each composed of four wheels. A set of four secondary wheels attached to the main carriage prevents the crane tilting due to the CoG misalignment of some loads. The elevation system proposed consists of an electromechanical crane of four independent drums and 50 tonnes payload. In parallel with the crane design, a logistics and space availability study has been carried out, leading to the detection of clearance or transport problems that could be taken into account in the final crane design.

  9. Superconducting solenoids for suspension of high-speed overhead transportation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Omel' yanenko, V I [Kharkov Polytechnical Inst., USSR; Bocharov, V I; Dolgosheev, E A; Usichenko, Y G

    1977-08-01

    A superconducting solenoid is the most important component of a suspension for overhead transportation facilities operating on the repulsion principle. Its design is aimed at producing an adequate magnetic field within the active zone, to ensure a high ratio of lifting force to braking force, the necessary speed dependence of both forces, and a high ratio of lifting force to solenoid mass. The design must also be both technologically and economically feasible. For safety considerations, the magnetic field intensity inside the passenger compartment must be minimum. A survey of existing designs indicates a preference for race track solenoids of quasi-rectangular shape. While all designers already agree on a coil width within 0.25 to 0.6 m, the optimum coil length has not yet been established. Intrinsic stabilization of superconductors by stranding and twisting has pushed the maximum allowable current density to 200 A/mm/sup 2/ and the energy storing capacity of magnets to 100 kJ, a capacity of 1 MJ being within reach. The recommended coil dimensions for laboratory models are 1 m length and 0.3 m width, to carry magnetizing currents up to 0.3 MA.

  10. STUDY REGARDING THE ALLOCATION OF PRODUCTION OVERHEADS PROCEDURE: CONVENTIONALITY, SUBJECTIVITY AND INFORMATION DISTORTION IN MANAGERIAL ACCOUNTING

    Directory of Open Access Journals (Sweden)

    GUINEA FLAVIUS-ANDREI

    2017-02-01

    Full Text Available Traditional methods of cost calculating have become obsolete. The loss of relevance of traditional cost calculating systems is mainly due to the existence of a gap between the current model of enterprise control and the model of analysis centres, as well as the difference between the way of composing the actual cost and its image reflected by managerial accounting. The vision of the company on which the method of analysis centres was based no longer corresponds to the present reality. The approach of this study captures the complex and delicate subject of the allocation of production overheads procedure. Through the field research undertaken, it was aimed to identify and possibly solve the problems related to the rational allocation of these expenditures. The own contributions of the study are highlighted in particular at practical level, as an obvious result of the types of research undertaken. One of the fundamental objectives of the present study is to enhance the interest regarding the practical possibilities of protecting against the dangers of a creative managerial accounting system. A managerial accounting system, once implemented, will also attract the manifestation of creative accounting phenomena, especially in times of crisis. Having at their disposal the most relevant set of information, managers are tempted to resort to more or less ingenious techniques that are more or less questionable and more or less legal, in order to improve the financial statement presentation.

  11. Low-overhead interference mitigation scheme for collaborative channel assignment in overloaded multiantenna femtocells

    KAUST Repository

    Radaydeh, Redha Mahmoud Mesleh

    2012-09-01

    This paper proposes a collaborative-based scheme for a transmit antenna channel assignment in overloaded multiantenna femtocells, with the aim of reducing the overhead load. It is assumed that multiple femtocell access points (FAPs) are deployed to sequentially allocate the available resources to scheduled users while reducing the interference experienced by each active user. The FAPs operate concurrently and each of them is allocated an orthogonal channel and employs a transmit array of arbitrary size. The suitable FAP and its associated transmit channel are then identified based on the noncoherently predicted interference power levels on available channels when feedback links are capacity limited. The effect of possible FAP failure or infeasibility to collaborate is characterized for different operating conditions. The applicability of the proposed scheme for specific cases, such as the use of directional antennas in each FAP or shared channels among different FAPs, is also discussed. For arbitrary statistical models of interference power levels on different channels, the average numbers of collaboration requests and examined transmit antenna channels are quantified. Moreover, the statistics of the resulting interference power are derived, which are then used to study various system performance measures. The effect of the interference threshold on the aforementioned measures for processing load and achieved performance is investigated. Numerical and simulations results are presented to support the analytical development and to clarify the tradeoff between the achieved performance enhancement using the proposed scheme and the required processing load for different operating scenarios. © 1967-2012 IEEE.

  12. Rollback recovery with low overhead for fault tolerance in mobile ad hoc networks

    Directory of Open Access Journals (Sweden)

    Parmeet Kaur Jaggi

    2015-10-01

    Full Text Available Mobile ad hoc networks (MANETs have significantly enhanced the wireless networks by eliminating the need for any fixed infrastructure. Hence, these are increasingly being used for expanding the computing capacity of existing networks or for implementation of autonomous mobile computing Grids. However, the fragile nature of MANETs makes the constituent nodes susceptible to failures and the computing potential of these networks can be utilized only if they are fault tolerant. The technique of checkpointing based rollback recovery has been used effectively for fault tolerance in static and cellular mobile systems; yet, the implementation of existing protocols for MANETs is not straightforward. The paper presents a novel rollback recovery protocol for handling the failures of mobile nodes in a MANET using checkpointing and sender based message logging. The proposed protocol utilizes the routing protocol existing in the network for implementing a low overhead recovery mechanism. The presented recovery procedure at a node is completely domino-free and asynchronous. The protocol is resilient to the dynamic characteristics of the MANET; allowing a distributed application to be executed independently without access to any wired Grid or cellular network access points. We also present an algorithm to record a consistent global snapshot of the MANET.

  13. Design of an overhead crane for the ITER NB cell remote handling maintenance operations

    International Nuclear Information System (INIS)

    Taubmann, Gonzalo; Brochet, Laurent; Liniers, Macarena; Medrano, Mercedes; Sarasola, Xabier; Botija, Jose; Alonso, Javier; Damiani, Carlo

    2009-01-01

    In the neutral beam cell of ITER all the maintenance operations on the neutral beam components (BLC's) must be performed by an overhead crane of large payload capability (30-50 tonnes). A crane system is presented consisting of a monorail, a carriage, and a lifting mechanism. The monorail must give access to the BLC's in the beam line vessel, the front components connecting the NB vessel with the Tokamak, and a storage area at the north end of the NB cell. Rail switching points are required at the intersections between radial and toroidal branches. A translational switching mechanism is proposed. The crane carriage consists of two independent sub-carriages, each composed of four wheels. A set of four secondary wheels attached to the main carriage prevents the crane tilting due to the CoG misalignment of some loads. The elevation system proposed consists of an electromechanical crane of four independent drums and 50 tonnes payload. In parallel with the crane design, a logistics and space availability study has been carried out, leading to the detection of clearance or transport problems that could be taken into account in the final crane design.

  14. Improving the Performance of CPU Architectures by Reducing the Operating System Overhead (Extended Version

    Directory of Open Access Journals (Sweden)

    Zagan Ionel

    2016-07-01

    Full Text Available The predictable CPU architectures that run hard real-time tasks must be executed with isolation in order to provide a timing-analyzable execution for real-time systems. The major problems for real-time operating systems are determined by an excessive jitter, introduced mainly through task switching. This can alter deadline requirements, and, consequently, the predictability of hard real-time tasks. New requirements also arise for a real-time operating system used in mixed-criticality systems, when the executions of hard real-time applications require timing predictability. The present article discusses several solutions to improve the performance of CPU architectures and eventually overcome the Operating Systems overhead inconveniences. This paper focuses on the innovative CPU implementation named nMPRA-MT, designed for small real-time applications. This implementation uses the replication and remapping techniques for the program counter, general purpose registers and pipeline registers, enabling multiple threads to share a single pipeline assembly line. In order to increase predictability, the proposed architecture partially removes the hazard situation at the expense of larger execution latency per one instruction.

  15. High Voltage Overhead Power Line Routing under an Objective Observability Criterion

    Directory of Open Access Journals (Sweden)

    L. Alfredo Fernandez-Jimenez

    2017-10-01

    Full Text Available The construction of new high voltage overhead power lines (HVOPLs has become a controversial issue for electricity companies due to social opposition. Citizens are concerned about how these power lines may have an impact on their lives, basically caused by their effects on health and safety. Visual impact is one of the most easily perceived. Although there are several published works that deal with the assessment of the visual impact produced by HVOPLs, no methodology has been proposed to assess this impact from an objective perspective. This work presents an original methodology which helps to identify the optimal routes for a new HVOPL under an objective observability criterion, enabling the selection of those with the lowest visibility in a zone. The application of the proposed methodology achieves a set of routes that links new HVOPL origin and destination points creating a corridor which includes all possible routes with an observability of its towers under a threshold limit. This methodology is illustrated by a real-life use corresponding to the selection of the route with least observability for a new power line in La Rioja (Spain. The results obtained may help to achieve a consensus between key stakeholders since it is focused on the specific issues of the planned HVOPL and its observability from an objective perspective.

  16. Error rates and resource overheads of encoded three-qubit gates

    Science.gov (United States)

    Takagi, Ryuji; Yoder, Theodore J.; Chuang, Isaac L.

    2017-10-01

    A non-Clifford gate is required for universal quantum computation, and, typically, this is the most error-prone and resource-intensive logical operation on an error-correcting code. Small, single-qubit rotations are popular choices for this non-Clifford gate, but certain three-qubit gates, such as Toffoli or controlled-controlled-Z (ccz), are equivalent options that are also more suited for implementing some quantum algorithms, for instance, those with coherent classical subroutines. Here, we calculate error rates and resource overheads for implementing logical ccz with pieceable fault tolerance, a nontransversal method for implementing logical gates. We provide a comparison with a nonlocal magic-state scheme on a concatenated code and a local magic-state scheme on the surface code. We find the pieceable fault-tolerance scheme particularly advantaged over magic states on concatenated codes and in certain regimes over magic states on the surface code. Our results suggest that pieceable fault tolerance is a promising candidate for fault tolerance in a near-future quantum computer.

  17. Low-overhead interference mitigation scheme for collaborative channel assignment in overloaded multiantenna femtocells

    KAUST Repository

    Radaydeh, Redha Mahmoud Mesleh; Alouini, Mohamed-Slim

    2012-01-01

    This paper proposes a collaborative-based scheme for a transmit antenna channel assignment in overloaded multiantenna femtocells, with the aim of reducing the overhead load. It is assumed that multiple femtocell access points (FAPs) are deployed to sequentially allocate the available resources to scheduled users while reducing the interference experienced by each active user. The FAPs operate concurrently and each of them is allocated an orthogonal channel and employs a transmit array of arbitrary size. The suitable FAP and its associated transmit channel are then identified based on the noncoherently predicted interference power levels on available channels when feedback links are capacity limited. The effect of possible FAP failure or infeasibility to collaborate is characterized for different operating conditions. The applicability of the proposed scheme for specific cases, such as the use of directional antennas in each FAP or shared channels among different FAPs, is also discussed. For arbitrary statistical models of interference power levels on different channels, the average numbers of collaboration requests and examined transmit antenna channels are quantified. Moreover, the statistics of the resulting interference power are derived, which are then used to study various system performance measures. The effect of the interference threshold on the aforementioned measures for processing load and achieved performance is investigated. Numerical and simulations results are presented to support the analytical development and to clarify the tradeoff between the achieved performance enhancement using the proposed scheme and the required processing load for different operating scenarios. © 1967-2012 IEEE.

  18. Research on Energy-Saving Design of Overhead Travelling Crane Camber Based on Probability Load Distribution

    Directory of Open Access Journals (Sweden)

    Tong Yifei

    2014-01-01

    Full Text Available Crane is a mechanical device, used widely to move materials in modern production. It is reported that the energy consumptions of China are at least 5–8 times of other developing countries. Thus, energy consumption becomes an unavoidable topic. There are several reasons influencing the energy loss, and the camber of the girder is the one not to be neglected. In this paper, the problem of the deflections induced by the moving payload in the girder of overhead travelling crane is examined. The evaluation of a camber giving a counterdeflection of the girder is proposed in order to get minimum energy consumptions for trolley to move along a nonstraight support. To this aim, probabilistic payload distributions are considered instead of fixed or rated loads involved in other researches. Taking 50/10 t bridge crane as a research object, the probability loads are determined by analysis of load distribution density functions. According to load distribution, camber design under different probability loads is discussed in detail as well as energy consumptions distribution. The research results provide the design reference of reasonable camber to obtain the least energy consumption for climbing corresponding to different P0; thus energy-saving design can be achieved.

  19. The US market for high-temperature superconducting wire in transmission cable applications

    Energy Technology Data Exchange (ETDEWEB)

    Forbes, D

    1996-04-01

    Telephone interviews were conducted with 23 utility engineers concerning the future prospects for high-temperature superconducting (HTS) transmission cables. All have direct responsibility for transmission in their utility, most of them in a management capacity. The engineers represented their utilities as members of the Electric Power Research Institute`s Underground Transmission Task Force (which has since been disbanded). In that capacity, they followed the superconducting transmission cable program and are aware of the cryogenic implications. Nineteen of the 23 engineers stated the market for underground transmission would grow during the next decade. Twelve of those specified an annual growth rate; the average of these responses was 5.6%. Adjusting that figure downward to incorporate the remaining responses, this study assumes an average growth rate of 3.4%. Factors driving the growth rate include the difficulty in securing rights-of-way for overhead lines, new construction techniques that reduce the costs of underground transmission, deregulation, and the possibility that public utility commissions will allow utilities to include overhead costs in their rate base. Utilities have few plans to replace existing cable as preventive maintenance, even though much of the existing cable has exceeded its 40-year lifetime. Ten of the respondents said the availability of a superconducting cable with the same life-cycle costs as a conventional cable and twice the ampacity would induce them to consider retrofits. The respondents said a cable with those characteristics would capture 73% of their cable retrofits.

  20. The acrylamide (S)-2 as a positive and negative modulator of Kv7 channels expressed in Xenopus laevis oocytes

    DEFF Research Database (Denmark)

    Blom, Sigrid Marie; Schmitt, Nicole; Jensen, Henrik Sindal

    2009-01-01

    Kv7.2-5, is now in clinical trial phase III for the treatment of partial onset seizures. One of the main obstacles in developing Kv7 channel active drugs has been to identify compounds that can discriminate between the neuronal subtypes, a feature that could help diminish side effects and increase...