WorldWideScience

Sample records for korean voxel model

  1. HDRK-Man: a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver

    International Nuclear Information System (INIS)

    Kim, Chan Hyeong; Jeong, Jong Hwi; Choi, Sang Hyoun; Lee, Choonsik; Chung, Min Suk

    2008-01-01

    A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future

  2. HDRK-Man: a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Hyeong; Jeong, Jong Hwi [Department of Nuclear Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Choi, Sang Hyoun [Department of radiation oncology, Inha University, 7-206, 3-ga, Shinheumg-dong, Jung-gu, Incheon, 400-711 (Korea, Republic of); Lee, Choonsik [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Chung, Min Suk [Department of Anatomy, Ajou University School of Medicine, San 5 Wonchon-dong, Yeongtong-gu, Suwon 443-749 (Korea, Republic of)], E-mail: chkim@hanyang.ac.kr

    2008-08-07

    A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future.

  3. Development of the Reference Korean Female Voxel Phantom

    International Nuclear Information System (INIS)

    Ham, Bo Kyoung; Cho, Kun Woo; Yeom, Yoen Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol

    2012-01-01

    The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.967 X 1.967 X X 2.0619 mm 3 and the voxel array size is 261 X 109 X 825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351 X 2.0351 X 2.0747 mm 3 for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

  4. Development of the Reference Korean Female Voxel Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Bo Kyoung; Cho, Kun Woo [University of Science and Technology, Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Yeom, Yoen Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol [Hanyang University, Seoul (Korea, Republic of)

    2012-03-15

    The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.967 X 1.967 X X 2.0619 mm{sup 3} and the voxel array size is 261 X 109 X 825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351 X 2.0351 X 2.0747 mm{sup 3} for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

  5. Construction of Korean adult voxel phantoms for radiation dosimetry and their applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik

    2002-08-15

    Although contribution of the MIRD-type mathematical anthropomorphic phantoms to computational radiation dosimetry, especially in determining the effective dose to the exposed personnel, is very significant, there remain some questions on possible deviation in the resulting dosimetric quantities from the true values. This is particularly the case for those organ or tissues having complicated geometry difficult to model with simple geometrical body elements. As an alternative approach to resolve the problem, there have been efforts to use voxel phantoms, which can very precisely describe both the external shape and the internal organs by virtue of fast advances in medical imaging technology as well as in computing power. In this study, Korean adult male and female voxel phantoms were constructed by processing whole-body MR images of healthy volunteers who belong to middle group of Korean in height and weight. Organs and tissues on tomographic images were manually segmented and indexed using the graphic software PL-400 . Due to limited resolution of the raw MR images, voxels of rather large size, 2 mmx2 mmx8 mm for the woman and 2mmx2mmx10mm for the man, were used. The resulting male and female voxel phantoms were named KRMAN and KRWOMAN, respectively. To assess utility of the voxel phatoms, calculations were carried out with the Monte Carlo code MCNP4B for two illustrative problems. A program VOXELMAKER1.0 was developed to convert the voxel phantom data into MCNP geometry input format. In the first example, organ equivalent doses and effective doses were evaluated for phantoms in broad parallel photon fields of different energies and directions and were compared to corresponding values given in ICRP 74 which were derived with the MIRD-type phantoms. No significant deviations between MIRD and voxel phantoms were found in the effective doses. Significant differences up to around factor of 2, however, were observed in organ equivalent doses for some organs including

  6. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver

    Science.gov (United States)

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-01

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  7. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Kim, Chan Hyeong; Han, Min Cheol; Jeong, Jong Hwi; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-01-01

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms. (paper)

  8. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver.

    Science.gov (United States)

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-21

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  9. Construction of Korean female voxel phantom and its application to dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Ik

    2001-08-15

    A Korean female voxel phantom was constructed to overcome the limitations of anatomical description of the existing MRD-type mathematical anthropomorphic phantom and the example dose calculations were carried out for the radiation protection by using it. This whole body voxel phantom was based on the MRIs of the Korean adult female who falls into the reference Korean female group. The cross sectional human pictures from VHP of NLM was adopted for the modification and compensation of the missing MRIs of Korean adult female that include legs below upper thighs. From the gastrointestinal and respiratory organ which make obscure organ edges because of their continuing motion, the general anatomical knowledge were applied for the segmentation process. The Korean female whole body voxel phantom named in HYWOMAN is composed of 1,392,400 voxels that have width x length x height of 4mm x 4mm x 8mm for each with the total of 20 organs identified. With MDNP4B code the tissue equivalent doses were calculated for the four different energies of 0.4, 0.8, 2 and 8 MeV broad parallel gamma beam in AP, PA, LLAT and RLAT directions. The tissue equivalent doses were compared with those of ORNL adult female phantom under the same irradiation conditions. Despite of the small organ differences there could be found the considerable differences in tissue equivalent doses for some organs including thyroid, esophagus, kidneys and spleen. The cause of these discrepancies were proved to be the position of the organs in the phantom and the consequent shielding effects. With the methodology of this study, Korean reference male and female age-grouped voxel phantoms can be constructed and consequently the dosimetry system for typical Korean people is to be established.

  10. Construction of Korean female voxel phantom and its application to dosimetry

    International Nuclear Information System (INIS)

    Lee, Choon Ik

    2001-08-01

    A Korean female voxel phantom was constructed to overcome the limitations of anatomical description of the existing MRD-type mathematical anthropomorphic phantom and the example dose calculations were carried out for the radiation protection by using it. This whole body voxel phantom was based on the MRIs of the Korean adult female who falls into the reference Korean female group. The cross sectional human pictures from VHP of NLM was adopted for the modification and compensation of the missing MRIs of Korean adult female that include legs below upper thighs. From the gastrointestinal and respiratory organ which make obscure organ edges because of their continuing motion, the general anatomical knowledge were applied for the segmentation process. The Korean female whole body voxel phantom named in HYWOMAN is composed of 1,392,400 voxels that have width x length x height of 4mm x 4mm x 8mm for each with the total of 20 organs identified. With MDNP4B code the tissue equivalent doses were calculated for the four different energies of 0.4, 0.8, 2 and 8 MeV broad parallel gamma beam in AP, PA, LLAT and RLAT directions. The tissue equivalent doses were compared with those of ORNL adult female phantom under the same irradiation conditions. Despite of the small organ differences there could be found the considerable differences in tissue equivalent doses for some organs including thyroid, esophagus, kidneys and spleen. The cause of these discrepancies were proved to be the position of the organs in the phantom and the consequent shielding effects. With the methodology of this study, Korean reference male and female age-grouped voxel phantoms can be constructed and consequently the dosimetry system for typical Korean people is to be established

  11. Voxel inversion of airborne electromagnetic data for improved model integration

    Science.gov (United States)

    Fiandaca, Gianluca; Auken, Esben; Kirkegaard, Casper; Vest Christiansen, Anders

    2014-05-01

    Inversion of electromagnetic data has migrated from single site interpretations to inversions including entire surveys using spatial constraints to obtain geologically reasonable results. Though, the model space is usually linked to the actual observation points. For airborne electromagnetic (AEM) surveys the spatial discretization of the model space reflects the flight lines. On the contrary, geological and groundwater models most often refer to a regular voxel grid, not correlated to the geophysical model space, and the geophysical information has to be relocated for integration in (hydro)geological models. We have developed a new geophysical inversion algorithm working directly in a voxel grid disconnected from the actual measuring points, which then allows for informing directly geological/hydrogeological models. The new voxel model space defines the soil properties (like resistivity) on a set of nodes, and the distribution of the soil properties is computed everywhere by means of an interpolation function (e.g. inverse distance or kriging). Given this definition of the voxel model space, the 1D forward responses of the AEM data are computed as follows: 1) a 1D model subdivision, in terms of model thicknesses, is defined for each 1D data set, creating "virtual" layers. 2) the "virtual" 1D models at the sounding positions are finalized by interpolating the soil properties (the resistivity) in the center of the "virtual" layers. 3) the forward response is computed in 1D for each "virtual" model. We tested the new inversion scheme on an AEM survey carried out with the SkyTEM system close to Odder, in Denmark. The survey comprises 106054 dual mode AEM soundings, and covers an area of approximately 13 km X 16 km. The voxel inversion was carried out on a structured grid of 260 X 325 X 29 xyz nodes (50 m xy spacing), for a total of 2450500 inversion parameters. A classical spatially constrained inversion (SCI) was carried out on the same data set, using 106054

  12. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  13. Quality Control of Geological Voxel Models using Experts' Gaze

    NARCIS (Netherlands)

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  14. Study on the Construction of a High-definition Whole-body Voxel Model based on Cadaver's Color Photographic Anatomical Slice Images and Monte Carlo Dose Calculations

    International Nuclear Information System (INIS)

    Choi, Sang Hyoun

    2007-08-01

    Ajou University School of Medicine made the serially sectioned anatomical images from the Visible Korean Human (VKH) Project in Korea. The VKH images, which are the high-resolution color photographic images, show the organs and tissues in the human body very clearly at 0.2 mm intervals. In this study, we constructed a high-quality voxel model (VKH-Man) with a total of 30 organs and tissues by manual and automatic segmentation method using the serially sectioned anatomical image data from the Visible Korean Human (VKH) project in Korea. The height and weight of VKH-Man voxel model is 164 cm and 57.6 kg, respectively, and the voxel resolution is 1.875 x 1.875 x 2 mm 3 . However, this voxel phantom can be used to calculate the organ and tissue doses of only one person. Therefore, in this study, we adjusted the voxel phantom to the 'Reference Korean' data to construct the voxel phantom that represents the radiation workers in Korea. The height and weight of the voxel model (HDRK-Man) that is finally developed are 171 cm and 68 kg, respectively, and the voxel resolution is 1.981 x 1.981 x 2.0854 mm 3 . VKH-Man and HDRK-Man voxel model were implemented in a Monte Carlo particle transport simulation code for calculation of the organ and tissue doses in various irradiation geometries. The calculated values were compared with each other to see the effect of the adjustment and also compared with other computational models (KTMAN-2, ICRP-74 and VIP-Man). According to the results, the adjustment of the voxel model was found hardly affect the dose calculations and most of the organ and tissue equivalent doses showed some differences among the models. These results shows that the difference in figure, and organ topology affects the organ doses more than the organ size. The calculated values of the effective dose from VKH-Man and HDRK-Man according to the ICRP-60 and upcoming ICRP recommendation were compared. For the other radiation geometries (AP, LLAT, RLAT) except for PA

  15. Development of prostate voxel models for brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Reis, Lucas P.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The tools developed recently in the areas of computer graphics and animation movies to computer games allow the creation of new voxel anthropomorphic phantoms with better resolution and thus, more anatomical details. These phantoms can be used in nuclear applications, especially in radiation protection for estimating doses in cases of occupational or accidental radioactive incidents, and in medical and biological applications. For dose estimates, the phantoms are coupled to a Monte Carlo code, which will be responsible for the transport of radiation in this environment. This study aimed to develop a computational tool to estimate the isodose curves in the prostate after brachytherapy seed implants. For this, we have created a model called FANTPROST in the shape of a 48 mm side cube, with a standard prostate inserted in the center of this cube with different distributions of brachytherapy seeds in this volume. The prostate, according to this model, was obtained from the phantom voxels MASH2 developed by Numerical Dosimetry Group, Department of Nuclear Energy - Federal University of Pernambuco. The modeling of the seeds, added to FANTPROST, was done through the use of geometric information of Iodine-125 Amersham 6711 commercial seed. The simulations were performed by the code MCNP5 for spatial distributions containing different amounts of seeds within the FANTPROST. The obtained curves allowed an estimation of the behavior of the maximum dose that decreases with distance, showing that this tool can be used for a more accurate analysis of the effects produced by the presence of such seeds in the prostate and its vicinity. (author)

  16. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2010-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density is the most important physical property of voxel model. Traditionally, when creating the Monte Carlo input files, the average tissue parameters recommended in ICRP report were used to assign each voxel in the existing voxel models. However, as each tissue consists of many voxels in which voxels are different in their densities, the method of assigning average tissue parameters doesn't take account of the voxel's discrepancy, and can't represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the density of which was derived from CT number. In order to compare with the traditional method, we have constructed two models from a same cadaver specimen date set. A CT-based pelvic voxel model called Pelvis-CT model, was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model, was also constructed, the densities of which were taken from ICRP Publication. The CT images and color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometries. The results were compared with those of given in ICRP74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis-Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model were agreed well with that of ICRP74 data. (author)

  17. Lattice Boltzmann heat transfer model for permeable voxels

    Science.gov (United States)

    Pereira, Gerald G.; Wu, Bisheng; Ahmed, Shakil

    2017-12-01

    We develop a gray-scale lattice Boltzmann (LB) model to study fluid flow combined with heat transfer for flow through porous media where voxels may be partially solid (or void). Heat transfer in rocks may lead to deformation, which in turn can modulate the fluid flow and so has significant contribution to rock permeability. The LB temperature field is compared to a finite difference solution of the continuum partial differential equations for fluid flow in a channel. Excellent quantitative agreement is found for both Poiseuille channel flow and Brinkman flow. The LB model is then applied to sample porous media such as packed beds and also more realistic sandstone rock sample, and both the convective and diffusive regimes are recovered when varying the thermal diffusivity. It is found that while the rock permeability can be comparatively small (order milli-Darcy), the temperature field can show significant variation depending on the thermal convection of the fluid. This LB method has significant advantages over other numerical methods such as finite and boundary element methods in dealing with coupled fluid flow and heat transfer in rocks which have irregular and nonsmooth pore spaces.

  18. A software tool for modification of human voxel models used for application in radiation protection

    International Nuclear Information System (INIS)

    Becker, Janine; Zankl, Maria; Petoussi-Henss, Nina

    2007-01-01

    This note describes a new software tool called 'VolumeChange' that was developed to modify the masses and location of organs of virtual human voxel models. A voxel model is a three-dimensional representation of the human body in the form of an array of identification numbers that are arranged in slices, rows and columns. Each entry in this array represents a voxel; organs are represented by those voxels having the same identification number. With this tool, two human voxel models were adjusted to fit the reference organ masses of a male and a female adult, as defined by the International Commission on Radiological Protection (ICRP). The alteration of an already existing voxel model is a complicated process, leading to many problems that have to be solved. To solve those intricacies in an easy way, a new software tool was developed and is presented here. If the organs are modified, no bit of tissue, i.e. voxel, may vanish nor should an extra one appear. That means that organs cannot be modified without considering the neighbouring tissue. Thus, the principle of organ modification is based on the reassignment of voxels from one organ/tissue to another; actually deleting and adding voxels is only possible at the external surface, i.e. skin. In the software tool described here, the modifications are done by semi-automatic routines but including human control. Because of the complexity of the matter, a skilled person has to validate that the applied changes to organs are anatomically reasonable. A graphical user interface was designed to fulfil the purpose of a comfortable working process, and an adequate graphical display of the modified voxel model was developed. Single organs, organ complexes and even whole limbs can be edited with respect to volume, shape and location. (note)

  19. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2011-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density and elemental composition are the most important physical properties of voxel model. Usually, when creating the Monte Carlo input files, the average tissue densities recommended in ICRP Publication were used to assign each voxel in the existing voxel models. As each tissue consists of many voxels with different densities, the conventional method of average tissue densities failed to take account of the voxel's discrepancy, and therefore could not represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the densities of which were derived from CT number. In order to compare with the traditional method, we constructed two models from the cadaver specimen dataset. A CT-based pelvic voxel model called Pelvis-CT model was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model was also constructed, the densities of which were taken from ICRP Publication. The CT images and the color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were both ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometry. The results were compared with those of given in ICRP Publication 74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis- Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model agreed well with that of ICRP Publication 74 data. (author)

  20. A Corner-Point-Grid-Based Voxelization Method for Complex Geological Structure Model with Folds

    Science.gov (United States)

    Chen, Qiyu; Mariethoz, Gregoire; Liu, Gang

    2017-04-01

    3D voxelization is the foundation of geological property modeling, and is also an effective approach to realize the 3D visualization of the heterogeneous attributes in geological structures. The corner-point grid is a representative data model among all voxel models, and is a structured grid type that is widely applied at present. When carrying out subdivision for complex geological structure model with folds, we should fully consider its structural morphology and bedding features to make the generated voxels keep its original morphology. And on the basis of which, they can depict the detailed bedding features and the spatial heterogeneity of the internal attributes. In order to solve the shortage of the existing technologies, this work puts forward a corner-point-grid-based voxelization method for complex geological structure model with folds. We have realized the fast conversion from the 3D geological structure model to the fine voxel model according to the rule of isocline in Ramsay's fold classification. In addition, the voxel model conforms to the spatial features of folds, pinch-out and other complex geological structures, and the voxels of the laminas inside a fold accords with the result of geological sedimentation and tectonic movement. This will provide a carrier and model foundation for the subsequent attribute assignment as well as the quantitative analysis and evaluation based on the spatial voxels. Ultimately, we use examples and the contrastive analysis between the examples and the Ramsay's description of isoclines to discuss the effectiveness and advantages of the method proposed in this work when dealing with the voxelization of 3D geologic structural model with folds based on corner-point grids.

  1. Voxel-based model construction from colored tomographic images

    International Nuclear Information System (INIS)

    Loureiro, Eduardo Cesar de Miranda

    2002-07-01

    This work presents a new approach in the construction of voxel-based phantoms that was implemented to simplify the segmentation process of organs and tissues reducing the time used in this procedure. The segmentation process is performed by painting tomographic images and attributing a different color for each organ or tissue. A voxel-based head and neck phantom was built using this new approach. The way as the data are stored allows an increasing in the performance of the radiation transport code. The program that calculates the radiation transport also works with image files. This capability allows image reconstruction showing isodose areas, under several points of view, increasing the information to the user. Virtual X-ray photographs can also be obtained allowing that studies could be accomplished looking for the radiographic techniques optimization assessing, at the same time, the doses in organs and tissues. The accuracy of the program here presented, called MCvoxEL, that implements this new approach, was tested by comparison to results from two modern and well-supported Monte Carlo codes. Dose conversion factors for parallel X-ray exposure were also calculated. (author)

  2. A visual LISP program for voxelizing AutoCAD solid models

    Science.gov (United States)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  3. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry.

    Science.gov (United States)

    Caracappa, Peter F; Rhodes, Ashley; Fiedler, Derek

    2014-09-21

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  4. Advances in constructing regional geological voxel models, illustrated by their application in aggregate resource assessments

    NARCIS (Netherlands)

    Maljers, D.; Stafleu, J.; Meulen, M.J. van der; Dambrink, R.M.

    2015-01-01

    Aggregate resource assessments, derived from three subsequent generations of voxel models, were compared in a qualitative way to illustrate and discuss modelling progress. We compared the models in terms of both methodology and usability. All three models were produced by the Geological Survey of

  5. Automating the segmentation of medical images for the production of voxel tomographic computational models

    International Nuclear Information System (INIS)

    Caon, M.

    2001-01-01

    Radiation dosimetry for the diagnostic medical imaging procedures performed on humans requires anatomically accurate, computational models. These may be constructed from medical images as voxel-based tomographic models. However, they are time consuming to produce and as a consequence, there are few available. This paper discusses the emergence of semi-automatic segmentation techniques and describes an application (iRAD) written in Microsoft Visual Basic that allows the bitmap of a medical image to be segmented interactively and semi-automatically while displayed in Microsoft Excel. iRAD will decrease the time required to construct voxel models. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  6. Creation of voxel-based models for paediatric dosimetry from automatic segmentation methods

    International Nuclear Information System (INIS)

    Acosta, O.; Li, R.; Ourselin, S.; Caon, M.

    2006-01-01

    Full text: The first computational models representing human anatomy were mathematical phantoms, but still far from accurate representations of human body. These models have been used with radiation transport codes (Monte Carlo) to estimate organ doses from radiological procedures. Although new medical imaging techniques have recently allowed the construction of voxel-based models based on the real anatomy, few children models from individual CT or MRI data have been reported [1,3]. For pediatric dosimetry purposes, a large range of voxel models by ages is required since scaling the anatomy from existing models is not sufficiently accurate. The small number of models available arises from the small number of CT or MRI data sets of children available and the long amount of time required to segment the data sets. The existing models have been constructed by manual segmentation slice by slice and using simple thresholding techniques. In medical image segmentation, considerable difficulties appear when applying classical techniques like thresholding or simple edge detection. Until now, any evidence of more accurate or near-automatic methods used in construction of child voxel models exists. We aim to construct a range of pediatric voxel models, integrating automatic or semi-automatic 3D segmentation techniques. In this paper we present the first stage of this work using pediatric CT data.

  7. An eye model for computational dosimetry using a multi-scale voxel phantom

    International Nuclear Information System (INIS)

    Caracappa, P.F.; Rhodes, A.; Fiedler, D.

    2013-01-01

    The lens of the eye is a radiosensitive tissue with cataract formation being the major concern. Recently reduced recommended dose limits to the lens of the eye have made understanding the dose to this tissue of increased importance. Due to memory limitations, the voxel resolution of computational phantoms used for radiation dose calculations is too large to accurately represent the dimensions of the eye. A revised eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and is then transformed into a high-resolution voxel model. This eye model is combined with an existing set of whole body models to form a multi-scale voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole body model are developed. When the Lattice Overlay method, the simpler of the two to define, is utilized, the computational penalty in terms of speed is noticeable and the figure of merit for the eye dose tally decreases by as much as a factor of two. When the Voxel Substitution method is applied, the penalty in speed is nearly trivial and the impact on the tally figure of merit is comparatively smaller. The origin of this difference in the code behavior may warrant further investigation

  8. Light regimes in Populus plantations using the Voxel-based Light Interception Model

    NARCIS (Netherlands)

    Van der Zande, D.; Dieussart, K.; Stuckens, J.; Verstraeten, W.W.; Coppin, P.

    2011-01-01

    Three-dimensional light interception by three uniform Populus canopies was studied using the Voxel-based Light Interception Model (VLIM) in combination with ground-based Light Detection and Ranging (LiDAR) measurements. As the VLIM was developed and validated in a virtual environment to ensure

  9. Micromechanical analysis of nanocomposites using 3D voxel based material model

    DEFF Research Database (Denmark)

    Mishnaevsky, Leon

    2012-01-01

    A computational study on the effect of nanocomposite structures on the elastic properties is carried out with the use of the 3D voxel based model of materials and the combined Voigt–Reuss method. A hierarchical voxel based model of a material reinforced by an array of exfoliated and intercalated...... nanoclay platelets surrounded by interphase layers is developed. With this model, the elastic properties of the interphase layer are estimated using the inverse analysis. The effects of aspect ratio, intercalation and orientation of nanoparticles on the elastic properties of the nanocomposites are analyzed....... For modeling the damage in nanocomposites with intercalated structures, “four phase” model is suggested, in which the strength of “intrastack interphase” is lower than that of “outer” interphase around the nanoplatelets. Analyzing the effect of nanoreinforcement in the matrix on the failure probability...

  10. William, a voxel model of child anatomy from tomographic images for Monte Carlo dosimetry calculations

    International Nuclear Information System (INIS)

    Caon, M.

    2010-01-01

    Full text: Medical imaging provides two-dimensional pictures of the human internal anatomy from which may be constructed a three-dimensional model of organs and tissues suitable for calculation of dose from radiation. Diagnostic CT provides the greatest exposure to radiation per examination and the frequency of CT examination is high. Esti mates of dose from diagnostic radiography are still determined from data derived from geometric models (rather than anatomical models), models scaled from adult bodies (rather than bodies of children) and CT scanner hardware that is no longer used. The aim of anatomical modelling is to produce a mathematical representation of internal anatomy that has organs of realistic size, shape and positioning. The organs and tissues are represented by a great many cuboidal volumes (voxels). The conversion of medical images to voxels is called segmentation and on completion every pixel in an image is assigned to a tissue or organ. Segmentation is time consuming. An image processing pack age is used to identify organ boundaries in each image. Thirty to forty tomographic voxel models of anatomy have been reported in the literature. Each model is of an individual, or a composite from several individuals. Images of children are particularly scarce. So there remains a need for more paediatric anatomical models. I am working on segmenting ''William'' who is 368 PET-CT images from head to toe of a seven year old boy. William will be used for Monte Carlo dose calculations of dose from CT examination using a simulated modern CT scanner.

  11. Setup of HDRK-Man voxel model in Geant4 Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Hwi; Cho, Sung Koo; Kim, Chan Hyeong [Hanyang Univ., Seoul (Korea, Republic of); Choi, Sang Hyoun [Inha Univ., Incheon (Korea, Republic of); Cho, Kun Woo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2008-10-15

    Many different voxel models, developed using tomographic images of human body, are used in various fields including both ionizing and non-ionizing radiation fields. Recently a high-quality voxel model/ named HDRK-Man, was constructed at Hanyang University and used to calculate the dose conversion coefficients (DCC) values for external photon and neutron beams using the MCNPX Monte Carlo code. The objective of the present study is to set up the HDRK-Man model in Geant4 in order to use it in more advanced calculations such as 4-D Monte Carlo simulations and space dosimetry studies involving very high energy particles. To that end, the HDRK-Man was ported to Geant4 and used to calculate the DCC values for external photon beams. The calculated values were then compared with the results of the MCNPX code. In addition, a computational Linux cluster was built to improve the computing speed in Geant4.

  12. Voxel anthropomorphic phantoms: review of models used for ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Lemosquet, A.; Carlan, L. de; Clairand, I.

    2003-01-01

    Computational anthropomorphic phantoms have been used since the 1970's for dosimetric calculations. Realistic geometries are required for this operation, resulting in the development of ever more accurate phantoms. Voxel phantoms, consisting of a set of small-volume elements, appeared towards the end of the 1980's, and significantly improved on the original mathematical models. Voxel phantoms are models of the human body, obtained using computed tomography (CT) or magnetic resonance images (MRI). These phantoms are an extremely accurate representation of the human anatomy. This article provides a review of the literature available on the development of these phantoms and their applications in ionising radiation dosimetry. The bibliographical study has shown that there is a wide range of phantoms, covering various characteristics of the general population in terms of sex, age or morphology, and that they are used in applications relating to all aspects of ionising radiation. (author)

  13. Evaluation of absorbed doses in voxel-based and simplified models for small animals

    International Nuclear Information System (INIS)

    Mohammadi, A.; Kinase, S.; Saito, K.

    2008-01-01

    Internal dosimetry in non-human biota is desirable from the viewpoint of radiation protection of the environment. The International Commission on Radiological Protection (ICRP) proposed Reference Animals and Plants using simplified models, such as ellipsoids and spheres and calculated absorbed fractions (AFs) for whole bodies. In this study, photon and electron AFs in whole bodies of voxel-based rat and frog models have been calculated and compared with AFs in the reference models. It was found that the voxel-based and the reference frog (or rat) models can be consistent for the whole-body AFs within a discrepancy of 25 %, as the source was uniformly distributed in the whole body. The specific absorbed fractions (SAFs) and S values were also evaluated in whole bodies and all organs of the voxel-based frog and rat models as the source was distributed in the whole body or skeleton. The results demonstrated that the whole-body SAFs reflect SAFs of all individual organs as the source was uniformly distributed per mass within the whole body by about 30 % uncertainties with exceptions for body contour (up to -40 %) for both electrons and photons due to enhanced radiation leakages, and for the skeleton for photons only (up to +185 %) due to differences in the mass attenuation coefficients. For nuclides such as 90 Y and 90 Sr, which were concentrated in the skeleton, there were large differences between S values in the whole body and those in individual organs, however the whole-body S values for the reference models with the whole body as the source were remarkably similar to those for the voxel-based models with the skeleton as the source, within about 4 and 0.3 %, respectively. It can be stated that whole-body SAFs or S values in simplified models without internal organs are not sufficient for accurate internal dosimetry because they do not reflect SAFs or S values of all individual organs as the source was not distributed uniformly in whole body. Thus, voxel

  14. Development and tests of a mouse voxel model dor MCNPX based on Digimouse images

    Energy Technology Data Exchange (ETDEWEB)

    Melo M, B.; Ferreira F, C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos No. 6627, Belo Horizonte 31270-901, Minas Gerais (Brazil); Garcia de A, I.; Machado T, B.; Passos Ribeiro de C, T., E-mail: bmm@cdtn.br [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Pte. Antonio Carlos 6627, Belo Horizonte 31270-901, Minas Gerais (Brazil)

    2015-10-15

    Mice have been widely used in experimental protocols involving ionizing radiation. Biological effects (Be) induced by radiation can compromise studies results. Good estimates of mouse whole body and organs absorbed dose could provide valuable information to researchers. The aim of this study was to create and test a new voxel phantom for mice dosimetry from -Digimouse- project images. Micro CT images from Digimouse project were used in this work. Corel PHOTOPAINT software was utilized in segmentation process. The three-dimensional (3-D) model assembly and its voxel size manipulation were performed by Image J. SISCODES was used to adapt the model to run in MCNPX Monte Carlo code. The resulting model was called DM{sub B}RA. The volume and mass of segmented organs were compared with data available in literature. For the preliminary tests the heart was considered the source organ. Photons of diverse energies were simulated and Saf values obtained through F6:p and + F6 MCNPX tallies. The results were compared with reference data. 3-D picturing of absorbed doses patterns and relative errors distribution were generated by a C++ -in house- made program and visualized through Amide software. The organ masses of DM{sub B}RA correlated well with two models that were based on same set of images. However some organs, like eyes and adrenals, skeleton and brain showed large discrepancies. Segmentation of an identical image set by different persons and/or methods can result significant organ masses variations. We believe that the main causes of these differences were: i) operator dependent subjectivity in the definition of organ limits during the segmentation processes; and i i) distinct voxel dimensions between evaluated models. Lack of reference data for mice models construction and dosimetry was detected. Comparison with other models originated from different mice strains also demonstrated that the anatomical and size variability can be significant. Use of + F6 tally for mouse

  15. Development and tests of a mouse voxel model dor MCNPX based on Digimouse images

    International Nuclear Information System (INIS)

    Melo M, B.; Ferreira F, C.; Garcia de A, I.; Machado T, B.; Passos Ribeiro de C, T.

    2015-10-01

    Mice have been widely used in experimental protocols involving ionizing radiation. Biological effects (Be) induced by radiation can compromise studies results. Good estimates of mouse whole body and organs absorbed dose could provide valuable information to researchers. The aim of this study was to create and test a new voxel phantom for mice dosimetry from -Digimouse- project images. Micro CT images from Digimouse project were used in this work. Corel PHOTOPAINT software was utilized in segmentation process. The three-dimensional (3-D) model assembly and its voxel size manipulation were performed by Image J. SISCODES was used to adapt the model to run in MCNPX Monte Carlo code. The resulting model was called DM B RA. The volume and mass of segmented organs were compared with data available in literature. For the preliminary tests the heart was considered the source organ. Photons of diverse energies were simulated and Saf values obtained through F6:p and + F6 MCNPX tallies. The results were compared with reference data. 3-D picturing of absorbed doses patterns and relative errors distribution were generated by a C++ -in house- made program and visualized through Amide software. The organ masses of DM B RA correlated well with two models that were based on same set of images. However some organs, like eyes and adrenals, skeleton and brain showed large discrepancies. Segmentation of an identical image set by different persons and/or methods can result significant organ masses variations. We believe that the main causes of these differences were: i) operator dependent subjectivity in the definition of organ limits during the segmentation processes; and i i) distinct voxel dimensions between evaluated models. Lack of reference data for mice models construction and dosimetry was detected. Comparison with other models originated from different mice strains also demonstrated that the anatomical and size variability can be significant. Use of + F6 tally for mouse phantoms

  16. Korean risk assessment model for breast cancer risk prediction.

    Science.gov (United States)

    Park, Boyoung; Ma, Seung Hyun; Shin, Aesun; Chang, Myung-Chul; Choi, Ji-Yeob; Kim, Sungwan; Han, Wonshik; Noh, Dong-Young; Ahn, Sei-Hyun; Kang, Daehee; Yoo, Keun-Young; Park, Sue K

    2013-01-01

    We evaluated the performance of the Gail model for a Korean population and developed a Korean breast cancer risk assessment tool (KoBCRAT) based upon equations developed for the Gail model for predicting breast cancer risk. Using 3,789 sets of cases and controls, risk factors for breast cancer among Koreans were identified. Individual probabilities were projected using Gail's equations and Korean hazard data. We compared the 5-year and lifetime risk produced using the modified Gail model which applied Korean incidence and mortality data and the parameter estimators from the original Gail model with those produced using the KoBCRAT. We validated the KoBCRAT based on the expected/observed breast cancer incidence and area under the curve (AUC) using two Korean cohorts: the Korean Multicenter Cancer Cohort (KMCC) and National Cancer Center (NCC) cohort. The major risk factors under the age of 50 were family history, age at menarche, age at first full-term pregnancy, menopausal status, breastfeeding duration, oral contraceptive usage, and exercise, while those at and over the age of 50 were family history, age at menarche, age at menopause, pregnancy experience, body mass index, oral contraceptive usage, and exercise. The modified Gail model produced lower 5-year risk for the cases than for the controls (p = 0.017), while the KoBCRAT produced higher 5-year and lifetime risk for the cases than for the controls (pKorean women, especially urban women.

  17. Synthetic digital radiographs using exposure computer models of Voxels / EGS4 Phantoms

    International Nuclear Information System (INIS)

    Kenned, Roberto; Vieira, Jose W.; Lima, Fernando R.A.; Loureiro, Eduardo

    2008-01-01

    The objective of this work is to produce synthetic digital radiographs from synthetic phantoms with the use of a Computational Model of Exposition (MCE). The literature explains a model consisted on a phantom, a Monte Carlo code and an algorithm of a radioactive source. In this work it was used the FAX phantom (Female Adult voXel), besides the EGS4 system code Eletron Shower-range version 4) and an external source, similar to that used in diagnostic radiology. The implementation of MCE creates files with information on external energy deposited in the voxels of fantoma used, here called EnergiaPorVoxel.dat. These files along with the targeted phantom (fax.sgi) worked as data entry for the DIP software (Digital Imaging Processing) to build the synthetic phantoms based on energy and the effective dose. This way you can save each slice that is the stack of pictures of these phantoms synthetics, which have been called synthetic digital radiography. Using this, it is possible to use techniques of emphasis in space to increase the contrast or elineate contours between organs and tissues. The practical use of these images is not only to allow a planning of examinations performed in clinics and hospitals and reducing unnecessary exposure to patients by error of radiographic techniques. (author)

  18. Assessment of body doses from photon exposures using human voxel models

    International Nuclear Information System (INIS)

    Zankl, M.; Fill, U.; Petoussi-Henss, N.; Regulla, D.

    2000-01-01

    For the scope of risk assessment in protection against ionising radiation (occupational, environmental and medical) it is necessary to determine the radiation dose to specific body organs and tissues. For this purpose, a series of models of the human body were designed in the past, together with computer codes simulating the radiation transport and energy deposition in the body. Most of the computational body models in use are so-called mathematical models; the most famous is the MIRD-5 phantom developed at Oak Ridge National Laboratory. In the 1980s, a new generation of human body models was introduced at GSF, constructed from whole body CT data. Due to being constructed from image data of real persons, these 'voxel models' offer an improved realism of external and internal shape of the body and its organs, compared to MIRD-type models. Comparison of dose calculations involving voxel models with respective dose calculations for MIRD-type models revealed that the deviation of the individual anatomy from that described in the MIRD-type models indeed introduces significant deviations of the calculated organ doses. Specific absorbed fractions of energy released in a source organ due to incorporated activity which are absorbed in target organs may differ by more than an order of magnitude between different body models; for external photon irradiation, the discrepancies are more moderate. (author)

  19. Surface mesh to voxel data registration for patient-specific anatomical modeling

    Science.gov (United States)

    de Oliveira, Júlia E. E.; Giessler, Paul; Keszei, András.; Herrler, Andreas; Deserno, Thomas M.

    2016-03-01

    Virtual Physiological Human (VPH) models are frequently used for training, planning, and performing medical procedures. The Regional Anaesthesia Simulator and Assistant (RASimAs) project has the goal of increasing the application and effectiveness of regional anesthesia (RA) by combining a simulator of ultrasound-guided and electrical nerve-stimulated RA procedures and a subject-specific assistance system through an integration of image processing, physiological models, subject-specific data, and virtual reality. Individualized models enrich the virtual training tools for learning and improving regional anaesthesia (RA) skills. Therefore, we suggest patient-specific VPH models that are composed by registering the general mesh-based models with patient voxel data-based recordings. Specifically, the pelvis region has been focused for the support of the femoral nerve block. The processing pipeline is composed of different freely available toolboxes such as MatLab, the open Simulation framework (SOFA), and MeshLab. The approach of Gilles is applied for mesh-to-voxel registration. Personalized VPH models include anatomical as well as mechanical properties of the tissues. Two commercial VPH models (Zygote and Anatomium) were used together with 34 MRI data sets. Results are presented for the skin surface and pelvic bones. Future work will extend the registration procedure to cope with all model tissue (i.e., skin, muscle, bone, vessel, nerve, fascia) in a one-step procedure and extrapolating the personalized models to body regions actually being out of the captured field of view.

  20. A voxel-based multiscale model to simulate the radiation response of hypoxic tumors.

    Science.gov (United States)

    Espinoza, I; Peschke, P; Karger, C P

    2015-01-01

    In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to improve this prediction and to optimize the treatment plan. A voxel-based multiscale tumor response model for simulating the radiation response of hypoxic tumors was developed. It considers viable and dead tumor cells, capillary and normal cells, as well as the most relevant biological processes such as (i) proliferation of tumor cells, (ii) hypoxia-induced angiogenesis, (iii) spatial exchange of cells leading to tumor growth, (iv) oxygen-dependent cell survival after irradiation, (v) resorption of dead cells, and (vi) spatial exchange of cells leading to tumor shrinkage. Oxygenation is described on a microscopic scale using a previously published tumor oxygenation model, which calculates the oxygen distribution for each voxel using the vascular fraction as the most important input parameter. To demonstrate the capabilities of the model, the dependence of the oxygen distribution on tumor growth and radiation-induced shrinkage is investigated. In addition, the impact of three different reoxygenation processes is compared and tumor control probability (TCP) curves for a squamous cells carcinoma of the head and neck (HNSSC) are simulated under normoxic and hypoxic conditions. The model describes the spatiotemporal behavior of the tumor on three different scales: (i) on the macroscopic scale, it describes tumor growth and shrinkage during radiation treatment, (ii) on a mesoscopic scale, it provides the cell density and vascular fraction for each voxel, and (iii) on the microscopic scale, the oxygen distribution may be obtained in terms of oxygen histograms. With increasing tumor size, the simulated tumors develop a hypoxic core. Within the model, tumor shrinkage was

  1. A voxel-based multiscale model to simulate the radiation response of hypoxic tumors

    International Nuclear Information System (INIS)

    Espinoza, I.; Peschke, P.; Karger, C. P.

    2015-01-01

    Purpose: In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to improve this prediction and to optimize the treatment plan. Methods: A voxel-based multiscale tumor response model for simulating the radiation response of hypoxic tumors was developed. It considers viable and dead tumor cells, capillary and normal cells, as well as the most relevant biological processes such as (i) proliferation of tumor cells, (ii) hypoxia-induced angiogenesis, (iii) spatial exchange of cells leading to tumor growth, (iv) oxygen-dependent cell survival after irradiation, (v) resorption of dead cells, and (vi) spatial exchange of cells leading to tumor shrinkage. Oxygenation is described on a microscopic scale using a previously published tumor oxygenation model, which calculates the oxygen distribution for each voxel using the vascular fraction as the most important input parameter. To demonstrate the capabilities of the model, the dependence of the oxygen distribution on tumor growth and radiation-induced shrinkage is investigated. In addition, the impact of three different reoxygenation processes is compared and tumor control probability (TCP) curves for a squamous cells carcinoma of the head and neck (HNSSC) are simulated under normoxic and hypoxic conditions. Results: The model describes the spatiotemporal behavior of the tumor on three different scales: (i) on the macroscopic scale, it describes tumor growth and shrinkage during radiation treatment, (ii) on a mesoscopic scale, it provides the cell density and vascular fraction for each voxel, and (iii) on the microscopic scale, the oxygen distribution may be obtained in terms of oxygen histograms. With increasing tumor size, the simulated tumors develop a hypoxic core. Within the

  2. MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection

    International Nuclear Information System (INIS)

    Bolch, Wesley

    2010-01-01

    The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2's Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2's revision of the target tissues of relevance for radiogenic bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-(micro)m cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-(micro)m layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public

  3. MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection

    Energy Technology Data Exchange (ETDEWEB)

    Bolch, Wesley [Univ. of Florida, Gainesville, FL (United States)

    2010-03-30

    The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2’s Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2’s revision of the target tissues of relevance for radiogenic bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-μm cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-μm layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public

  4. AUTOMATED VOXEL MODEL FROM POINT CLOUDS FOR STRUCTURAL ANALYSIS OF CULTURAL HERITAGE

    Directory of Open Access Journals (Sweden)

    G. Bitelli

    2016-06-01

    Full Text Available In the context of cultural heritage, an accurate and comprehensive digital survey of a historical building is today essential in order to measure its geometry in detail for documentation or restoration purposes, for supporting special studies regarding materials and constructive characteristics, and finally for structural analysis. Some proven geomatic techniques, such as photogrammetry and terrestrial laser scanning, are increasingly used to survey buildings with different complexity and dimensions; one typical product is in form of point clouds. We developed a semi-automatic procedure to convert point clouds, acquired from laserscan or digital photogrammetry, to a filled volume model of the whole structure. The filled volume model, in a voxel format, can be useful for further analysis and also for the generation of a Finite Element Model (FEM of the surveyed building. In this paper a new approach is presented with the aim to decrease operator intervention in the workflow and obtain a better description of the structure. In order to achieve this result a voxel model with variable resolution is produced. Different parameters are compared and different steps of the procedure are tested and validated in the case study of the North tower of the San Felice sul Panaro Fortress, a monumental historical building located in San Felice sul Panaro (Modena, Italy that was hit by an earthquake in 2012.

  5. Predicting drought propagation within peat layers using a three dimensionally explicit voxel based model

    Science.gov (United States)

    Condro, A. A.; Pawitan, H.; Risdiyanto, I.

    2018-05-01

    Peatlands are very vulnerable to widespread fires during dry seasons, due to availability of aboveground fuel biomass on the surface and belowground fuel biomass on the sub-surface. Hence, understanding drought propagation occurring within peat layers is crucial with regards to disaster mitigation activities on peatlands. Using a three dimensionally explicit voxel-based model of peatland hydrology, this study predicted drought propagation time lags into sub-surface peat layers after drought events occurrence on the surface of about 1 month during La-Nina and 2.5 months during El-Nino. The study was carried out on a high-conservation-value area of oil palm plantation in West Kalimantan. Validity of the model was evaluated and its applicability for disaster mitigation was discussed. The animations of simulated voxels are available at: goo.gl/HDRMYN (El-Nino 2015 episode) and goo.gl/g1sXPl (La-Nina 2016 episode). The model is available at: goo.gl/RiuMQz.

  6. Absorbed dose evaluation based on a computational voxel model incorporating distinct cerebral structures

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas; Trindade, Bruno; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)]. E-mail: samiabrandao@gmail.com; bmtrindade@yahoo.com; campos@nuclear.ufmg.br

    2007-07-01

    Brain tumors are quite difficult to treat due to the collateral radiation damages produced on the patients. Despite of the improvements in the therapeutics protocols for this kind of tumor, involving surgery and radiotherapy, the failure rate is still extremely high. This fact occurs because tumors can not often be totally removed by surgery since it may produce some type of deficit in the cerebral functions. Radiotherapy is applied after the surgery, and both are palliative treatments. During radiotherapy the brain does not absorb the radiation dose in homogeneous way, because the various density and chemical composition of tissues involved. With the intention of evaluating better the harmful effects caused by radiotherapy it was developed an elaborated cerebral voxel model to be used in computational simulation of the irradiation protocols of brain tumors. This paper presents some structures function of the central nervous system and a detailed cerebral voxel model, created in the SISCODES program, considering meninges, cortex, gray matter, white matter, corpus callosum, limbic system, ventricles, hypophysis, cerebellum, brain stem and spinal cord. The irradiation protocol simulation was running in the MCNP5 code. The model was irradiated with photons beam whose spectrum simulates a linear accelerator of 6 MV. The dosimetric results were exported to SISCODES, which generated the isodose curves for the protocol. The percentage isodose curves in the brain are present in this paper. (author)

  7. Construction of Korean male tomographic model segmented from PET-CT data

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Park, Sang Kyun; Lee, Jai Ki

    2004-01-01

    Tomographic human models provide currently the most realistic representation of human anatomy for radiation dosimetry calculation. Most of the models have been constructed by using computed tomographic (CT) or magnetic resonance (MR) images obtained from a single individual. Each scan has its inherent advantages and disadvantages. CT scan gives a considerable radiation dose to a subject, and MR scan takes too long time to get clear images of an immobile subject. An emerging source of medical images for the construction of tomographic models is PET-CT, which is performed when looking for cancer. In this study, a tomographic model of Korean adult male was developed by processing whole-body CT images of a PET-CT-scanned healthy volunteer. The 343 slices of the CT images were semi-automatically segmented layer by layer using a graphic software and screen digitizer. The 3rd Korean tomographic model, named KRMAN-2, consisting of 300x150x344 voxels of a size of 2x2x5mm 3 , was constructed. Examples of application to Monte Carlo radiation dosimetry calculation in idealized whole-body irradiations were given and discussed

  8. A voxel-based finite element model for the prediction of bladder deformation

    Energy Technology Data Exchange (ETDEWEB)

    Xiangfei, Chai; Herk, Marcel van; Hulshof, Maarten C. C. M.; Bel, Arjan [Radiation Oncology Department, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam (Netherlands); Radiation Oncology Department, Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands); Radiation Oncology Department, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam (Netherlands)

    2012-01-15

    Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classical FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to

  9. A voxel-based finite element model for the prediction of bladder deformation

    International Nuclear Information System (INIS)

    Chai Xiangfei; Herk, Marcel van; Hulshof, Maarten C. C. M.; Bel, Arjan

    2012-01-01

    Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classical FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to

  10. Voxel-based models representing the male and female ICRP reference adult - the skeleton

    International Nuclear Information System (INIS)

    Zankl, M.; Eckerman, K.F.; Bolch, W.E.

    2007-01-01

    For the forthcoming update of organ dose conversion coefficients, the International Commission on Radiological Protection (ICRP) will use voxel-based computational phantoms due to their improved anatomical realism compared with the class of mathematical or stylized phantoms used previously. According to the ICRP philosophy, these phantoms should be representative of the male and female reference adults with respect to their external dimensions, their organ topology and their organ masses. To meet these requirements, reference models of an adult male and adult female have been constructed at the GSF, based on existing voxel models segmented from tomographic images of two individuals whose body height and weight closely resemble the ICRP Publication 89 reference values. The skeleton is a highly complex structure of the body, composed of cortical bone, trabecular bone, red and yellow bone marrow and endosteum ('bone surfaces' in their older terminology). The skeleton of the reference phantoms consists of 19 individually segmented bones and bone groups. Sub-division of these bones into the above-mentioned constituents would be necessary in order to allow a direct calculation of dose to red bone marrow and endosteum. However, the dimensions of the trabeculae, the cavities containing bone marrow and the endosteum layer lining these cavities are clearly smaller than the resolution of a normal CT scan and, thus, these volumes could not be segmented in the tomographic images. As an attempt to represent the gross spatial distribution of these regions as realistically as possible at the given voxel resolution, 48 individual organ identification numbers were assigned to various parts of the skeleton: every segmented bone was subdivided into an outer shell of cortical bone and a spongious core; in the shafts of the long bones, a medullary cavity was additionally segmented. Using the data from ICRP Publication 89 on elemental tissue composition, from ICRU Report 46 on material

  11. Development of Japanese voxel models and their application to organ dose calculation

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2007-01-01

    Three Japanese voxel (volume pixel) phantoms in supine and upright postures, which are consisted of about 1 mm 3 size voxels, have been developed on the basis of computed tomography (CT) images of healthy Japanese adult male and female volunteers. Their body structures are reproduced more realistically in comparison with most existing voxel phantoms. Organ doses due to internal or external exposures were calculated using the developed phantoms. In estimation of radiation dose from radionuclides incorporated into body, specific absorbed fractions (SAFs) for low energy photon were significantly influenced by the changes in postures. In estimation of organ doses due to external exposures, the doses of some organs of the developed phantom were calculated and were compared with those of a previous Japanese voxel phantom (voxel size: 0.98x0.98x10 mm 3 ) and the reference values of ICRP Publication 74. (author)

  12. Voxel2MCNP: a framework for modeling, simulation and evaluation of radiation transport scenarios for Monte Carlo codes

    International Nuclear Information System (INIS)

    Pölz, Stefan; Laubersheimer, Sven; Eberhardt, Jakob S; Harrendorf, Marco A; Keck, Thomas; Benzler, Andreas; Breustedt, Bastian

    2013-01-01

    The basic idea of Voxel2MCNP is to provide a framework supporting users in modeling radiation transport scenarios using voxel phantoms and other geometric models, generating corresponding input for the Monte Carlo code MCNPX, and evaluating simulation output. Applications at Karlsruhe Institute of Technology are primarily whole and partial body counter calibration and calculation of dose conversion coefficients. A new generic data model describing data related to radiation transport, including phantom and detector geometries and their properties, sources, tallies and materials, has been developed. It is modular and generally independent of the targeted Monte Carlo code. The data model has been implemented as an XML-based file format to facilitate data exchange, and integrated with Voxel2MCNP to provide a common interface for modeling, visualization, and evaluation of data. Also, extensions to allow compatibility with several file formats, such as ENSDF for nuclear structure properties and radioactive decay data, SimpleGeo for solid geometry modeling, ImageJ for voxel lattices, and MCNPX’s MCTAL for simulation results have been added. The framework is presented and discussed in this paper and example workflows for body counter calibration and calculation of dose conversion coefficients is given to illustrate its application. (paper)

  13. Construction of anthropomorphic hybrid, dual-lattice voxel models for optimizing image quality and dose in radiography

    Science.gov (United States)

    Petoussi-Henss, Nina; Becker, Janine; Greiter, Matthias; Schlattl, Helmut; Zankl, Maria; Hoeschen, Christoph

    2014-03-01

    In radiography there is generally a conflict between the best image quality and the lowest possible patient dose. A proven method of dosimetry is the simulation of radiation transport in virtual human models (i.e. phantoms). However, while the resolution of these voxel models is adequate for most dosimetric purposes, they cannot provide the required organ fine structures necessary for the assessment of the imaging quality. The aim of this work is to develop hybrid/dual-lattice voxel models (called also phantoms) as well as simulation methods by which patient dose and image quality for typical radiographic procedures can be determined. The results will provide a basis to investigate by means of simulations the relationships between patient dose and image quality for various imaging parameters and develop methods for their optimization. A hybrid model, based on NURBS (Non Linear Uniform Rational B-Spline) and PM (Polygon Mesh) surfaces, was constructed from an existing voxel model of a female patient. The organs of the hybrid model can be then scaled and deformed in a non-uniform way i.e. organ by organ; they can be, thus, adapted to patient characteristics without losing their anatomical realism. Furthermore, the left lobe of the lung was substituted by a high resolution lung voxel model, resulting in a dual-lattice geometry model. "Dual lattice" means in this context the combination of voxel models with different resolution. Monte Carlo simulations of radiographic imaging were performed with the code EGS4nrc, modified such as to perform dual lattice transport. Results are presented for a thorax examination.

  14. The Relevance Voxel Machine (RVoxM): A Self-Tuning Bayesian Model for Informative Image-Based Prediction

    DEFF Research Database (Denmark)

    Sabuncu, Mert R.; Van Leemput, Koen

    2012-01-01

    This paper presents the relevance voxel machine (RVoxM), a dedicated Bayesian model for making predictions based on medical imaging data. In contrast to the generic machine learning algorithms that have often been used for this purpose, the method is designed to utilize a small number of spatially...

  15. MATSIM -The Development and Validation of a Numerical Voxel Model based on the MATROSHKA Phantom

    Science.gov (United States)

    Beck, Peter; Rollet, Sofia; Berger, Thomas; Bergmann, Robert; Hajek, Michael; Latocha, Marcin; Vana, Norbert; Zechner, Andrea; Reitz, Guenther

    The AIT Austrian Institute of Technology coordinates the project MATSIM (MATROSHKA Simulation) in collaboration with the Vienna University of Technology and the German Aerospace Center. The aim of the project is to develop a voxel-based model of the MATROSHKA anthro-pomorphic torso used at the International Space Station (ISS) as foundation to perform Monte Carlo high-energy particle transport simulations for different irradiation conditions. Funded by the Austrian Space Applications Programme (ASAP), MATSIM is a co-investigation with the European Space Agency (ESA) ELIPS project MATROSHKA, an international collaboration of more than 18 research institutes and space agencies from all over the world, under the science and project lead of the German Aerospace Center. The MATROSHKA facility is designed to determine the radiation exposure of an astronaut onboard ISS and especially during an ex-travehicular activity. The numerical model developed in the frame of MATSIM is validated by reference measurements. In this report we give on overview of the model development and compare photon and neutron irradiations of the detector-equipped phantom torso with Monte Carlo simulations using FLUKA. Exposure to Co-60 photons was realized in the standard ir-radiation laboratory at Seibersdorf, while investigations with neutrons were performed at the thermal column of the Vienna TRIGA Mark-II reactor. The phantom was loaded with passive thermoluminescence dosimeters. In addition, first results of the calculated dose distribution within the torso are presented for a simulated exposure in low-Earth orbit.

  16. Nighttime Foreground Pedestrian Detection Based on Three-Dimensional Voxel Surface Model

    Directory of Open Access Journals (Sweden)

    Jing Li

    2017-10-01

    Full Text Available Pedestrian detection is among the most frequently-used preprocessing tasks in many surveillance application fields, from low-level people counting to high-level scene understanding. Even though many approaches perform well in the daytime with sufficient illumination, pedestrian detection at night is still a critical and challenging problem for video surveillance systems. To respond to this need, in this paper, we provide an affordable solution with a near-infrared stereo network camera, as well as a novel three-dimensional foreground pedestrian detection model. Specifically, instead of using an expensive thermal camera, we build a near-infrared stereo vision system with two calibrated network cameras and near-infrared lamps. The core of the system is a novel voxel surface model, which is able to estimate the dynamic changes of three-dimensional geometric information of the surveillance scene and to segment and locate foreground pedestrians in real time. A free update policy for unknown points is designed for model updating, and the extracted shadow of the pedestrian is adopted to remove foreground false alarms. To evaluate the performance of the proposed model, the system is deployed in several nighttime surveillance scenes. Experimental results demonstrate that our method is capable of nighttime pedestrian segmentation and detection in real time under heavy occlusion. In addition, the qualitative and quantitative comparison results show that our work outperforms classical background subtraction approaches and a recent RGB-D method, as well as achieving comparable performance with the state-of-the-art deep learning pedestrian detection method even with a much lower hardware cost.

  17. Nighttime Foreground Pedestrian Detection Based on Three-Dimensional Voxel Surface Model.

    Science.gov (United States)

    Li, Jing; Zhang, Fangbing; Wei, Lisong; Yang, Tao; Lu, Zhaoyang

    2017-10-16

    Pedestrian detection is among the most frequently-used preprocessing tasks in many surveillance application fields, from low-level people counting to high-level scene understanding. Even though many approaches perform well in the daytime with sufficient illumination, pedestrian detection at night is still a critical and challenging problem for video surveillance systems. To respond to this need, in this paper, we provide an affordable solution with a near-infrared stereo network camera, as well as a novel three-dimensional foreground pedestrian detection model. Specifically, instead of using an expensive thermal camera, we build a near-infrared stereo vision system with two calibrated network cameras and near-infrared lamps. The core of the system is a novel voxel surface model, which is able to estimate the dynamic changes of three-dimensional geometric information of the surveillance scene and to segment and locate foreground pedestrians in real time. A free update policy for unknown points is designed for model updating, and the extracted shadow of the pedestrian is adopted to remove foreground false alarms. To evaluate the performance of the proposed model, the system is deployed in several nighttime surveillance scenes. Experimental results demonstrate that our method is capable of nighttime pedestrian segmentation and detection in real time under heavy occlusion. In addition, the qualitative and quantitative comparison results show that our work outperforms classical background subtraction approaches and a recent RGB-D method, as well as achieving comparable performance with the state-of-the-art deep learning pedestrian detection method even with a much lower hardware cost.

  18. A new algorithm for finite element simulation of wedge osteotomies in voxel models with application to the tibia

    Directory of Open Access Journals (Sweden)

    Thomas Pressel

    2010-01-01

    Full Text Available Thomas Pressel1, Markus D Schofer1, Jörg Meiforth2, Markus Lengsfeld1, Jan Schmitt11Department of Orthopaedics and Rheumatology, University Hospital Marburg, Marburg, Germany; 2St. Vincentius Kliniken, Klinik für Orthopädie, Karlsruhe, GermanyAbstract: Wedge osteotomies are used to correct bone deformities or change the forces acting on bones and joints in the human body. Finite element models can be employed to simulate the effect of such operations on the bone or adjacent joints. The automatic generation of voxel models derived from computed tomography data is a common procedure, but the major drawback of the method lies in irregular model surfaces. Therefore, the concept of hybrid models combining voxel and tetrahedron meshes was developed. We present an algorithm to simulate wedge osteotomies in voxel models by adding tetrahedron to brick elements. Applicability of the procedure was tested by performing a parametric study using a tibia model created from computed tomography scans taken in vivo applying individually calculated force conditions. The osteotomy angle largely affected maximum stresses: at 2.5 degrees valgus, the stresses at the medial and lateral tibial plateau were equivalent, while increasing valgus angles reduced medial stresses. The algorithm described here is an improvement of former mesh generation procedures and allows a better representation of the geometry at the osteotomy level. The algorithm can be used for all wedge osteotomies and is not limited to the tibia.Keywords: finite element/osteotomy/voxel/pre-operative planning, simulation, mesh algorithm

  19. From Particles and Point Clouds to Voxel Models: High Resolution Modeling of Dynamic Landscapes in Open Source GIS

    Science.gov (United States)

    Mitasova, H.; Hardin, E. J.; Kratochvilova, A.; Landa, M.

    2012-12-01

    Multitemporal data acquired by modern mapping technologies provide unique insights into processes driving land surface dynamics. These high resolution data also offer an opportunity to improve the theoretical foundations and accuracy of process-based simulations of evolving landforms. We discuss development of new generation of visualization and analytics tools for GRASS GIS designed for 3D multitemporal data from repeated lidar surveys and from landscape process simulations. We focus on data and simulation methods that are based on point sampling of continuous fields and lead to representation of evolving surfaces as series of raster map layers or voxel models. For multitemporal lidar data we present workflows that combine open source point cloud processing tools with GRASS GIS and custom python scripts to model and analyze dynamics of coastal topography (Figure 1) and we outline development of coastal analysis toolbox. The simulations focus on particle sampling method for solving continuity equations and its application for geospatial modeling of landscape processes. In addition to water and sediment transport models, already implemented in GIS, the new capabilities under development combine OpenFOAM for wind shear stress simulation with a new module for aeolian sand transport and dune evolution simulations. Comparison of observed dynamics with the results of simulations is supported by a new, integrated 2D and 3D visualization interface that provides highly interactive and intuitive access to the redesigned and enhanced visualization tools. Several case studies will be used to illustrate the presented methods and tools and demonstrate the power of workflows built with FOSS and highlight their interoperability.Figure 1. Isosurfaces representing evolution of shoreline and a z=4.5m contour between the years 1997-2011at Cape Hatteras, NC extracted from a voxel model derived from series of lidar-based DEMs.

  20. New format for storage of voxel phantom, and exposure computer model EGS4/MAX to EGSnrc/MASH update

    International Nuclear Information System (INIS)

    Leal Neto, Viriato; Vieira, Jose W.; Lima, Fernando R.A.; Lima, Lindeval F.

    2011-01-01

    In order to estimate the dosage absorbed by those subjected to ionizing radiation, it is necessary to perform simulations using the exposure computational model (ECM). Such models are consists essentially of an anthropomorphic phantom and a Monte Carlo code (MC). The conjunction of a voxel phantom of the MC code is a complex process and often results in solving a specific problem. This is partly due to the way the phantom voxel is stored on a computer. It is usually required a substantial amount of space to store a static representation of the human body and also a significant amount of memory for reading and processing a given simulation. This paper presents a new way to store data concerning the geometry irradiated (similar to the technique of repeated structures used in the geometry of MCNP code), reducing by 52% the disk space required for storage when compared to the previous format applied by Grupo de Dosimetria Numerica (GDN/CNPq). On the other hand, research in numerical dosimetry leads to a constant improvement on the resolution of voxel phantoms leading thus to a new requirement, namely, to develop new estimates of dose. Therefore, this work also performs an update of the MAX (Male Adult voXel)/EGS4 ECM for the MASH (Adult MaleMeSH)/EGSnrc ECM and presents instances of dosimetric evaluations using the new ECM. Besides the update of the phantom and the MC code, the algorithm of the source used has also been improved in contrast to previous publications. (author)

  1. Optimization of digital chest radiography using computer modeling and voxels phantoms

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.

    2009-01-01

    The purpose of this work is to use the Monte Carlo code MCNPX and the Female Adult voxel (FAX) and Male Adult voxel (MAX) phantoms to investigate how the dose and image quality in digital chest radiography vary with tube voltage (70-150 kV), anti-scatter methods (grid and air gap) and gender of the patient. The effective dose was calculated by ICRP60 and image quality was quantified by calculating the signal-difference-to-noise ratio for pathological details (calcifications) positioned at different locations in the anatomy. Calculated quantities were normalized to a fixed value of air kerma (5 μGy) at the automatic exposure control chambers. The results obtained in this work show that the air gap technique and lower tube voltages provide an increase in the digital image quality. Furthermore, this study has also shown that the detection of pathological details vary with the gender of the patient. (author)

  2. The SENSE-Isomorphism Theoretical Image Voxel Estimation (SENSE-ITIVE) Model for Reconstruction and Observing Statistical Properties of Reconstruction Operators

    Science.gov (United States)

    Bruce, Iain P.; Karaman, M. Muge; Rowe, Daniel B.

    2012-01-01

    The acquisition of sub-sampled data from an array of receiver coils has become a common means of reducing data acquisition time in MRI. Of the various techniques used in parallel MRI, SENSitivity Encoding (SENSE) is one of the most common, making use of a complex-valued weighted least squares estimation to unfold the aliased images. It was recently shown in Bruce et al. [Magn. Reson. Imag. 29(2011):1267–1287] that when the SENSE model is represented in terms of a real-valued isomorphism, it assumes a skew-symmetric covariance between receiver coils, as well as an identity covariance structure between voxels. In this manuscript, we show that not only is the skew-symmetric coil covariance unlike that of real data, but the estimated covariance structure between voxels over a time series of experimental data is not an identity matrix. As such, a new model, entitled SENSE-ITIVE, is described with both revised coil and voxel covariance structures. Both the SENSE and SENSE-ITIVE models are represented in terms of real-valued isomorphisms, allowing for a statistical analysis of reconstructed voxel means, variances, and correlations resulting from the use of different coil and voxel covariance structures used in the reconstruction processes to be conducted. It is shown through both theoretical and experimental illustrations that the miss-specification of the coil and voxel covariance structures in the SENSE model results in a lower standard deviation in each voxel of the reconstructed images, and thus an artificial increase in SNR, compared to the standard deviation and SNR of the SENSE-ITIVE model where both the coil and voxel covariances are appropriately accounted for. It is also shown that there are differences in the correlations induced by the reconstruction operations of both models, and consequently there are differences in the correlations estimated throughout the course of reconstructed time series. These differences in correlations could result in meaningful

  3. Rotating and translating anthropomorphic head voxel models to establish an horizontal Frankfort plane for dental CBCT Monte Carlo simulations: a dose comparison study

    Science.gov (United States)

    Stratis, A.; Zhang, G.; Jacobs, R.; Bogaerts, R.; Bosmans, H.

    2016-12-01

    In order to carry out Monte Carlo (MC) dosimetry studies, voxel phantoms, modeling human anatomy, and organ-based segmentation of CT image data sets are applied to simulation frameworks. The resulting voxel phantoms preserve patient CT acquisition geometry; in the case of head voxel models built upon head CT images, the head support with which CT scanners are equipped introduces an inclination to the head, and hence to the head voxel model. In dental cone beam CT (CBCT) imaging, patients are always positioned in such a way that the Frankfort line is horizontal, implying that there is no head inclination. The orientation of the head is important, as it influences the distance of critical radiosensitive organs like the thyroid and the esophagus from the x-ray tube. This work aims to propose a procedure to adjust head voxel phantom orientation, and to investigate the impact of head inclination on organ doses in dental CBCT MC dosimetry studies. The female adult ICRP, and three in-house-built paediatric voxel phantoms were in this study. An EGSnrc MC framework was employed to simulate two commonly used protocols; a Morita Accuitomo 170 dental CBCT scanner (FOVs: 60  ×  60 mm2 and 80  ×  80 mm2, standard resolution), and a 3D Teeth protocol (FOV: 100  ×  90 mm2) in a Planmeca Promax 3D MAX scanner. Result analysis revealed large absorbed organ dose differences in radiosensitive organs between the original and the geometrically corrected voxel models of this study, ranging from  -45.6% to 39.3%. Therefore, accurate dental CBCT MC dose calculations require geometrical adjustments to be applied to head voxel models.

  4. Organ dose conversion coefficients based on a voxel mouse model and MCNP code for external photon irradiation.

    Science.gov (United States)

    Zhang, Xiaomin; Xie, Xiangdong; Cheng, Jie; Ning, Jing; Yuan, Yong; Pan, Jie; Yang, Guoshan

    2012-01-01

    A set of conversion coefficients from kerma free-in-air to the organ absorbed dose for external photon beams from 10 keV to 10 MeV are presented based on a newly developed voxel mouse model, for the purpose of radiation effect evaluation. The voxel mouse model was developed from colour images of successive cryosections of a normal nude male mouse, in which 14 organs or tissues were segmented manually and filled with different colours, while each colour was tagged by a specific ID number for implementation of mouse model in Monte Carlo N-particle code (MCNP). Monte Carlo simulation with MCNP was carried out to obtain organ dose conversion coefficients for 22 external monoenergetic photon beams between 10 keV and 10 MeV under five different irradiation geometries conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic). Organ dose conversion coefficients were presented in tables and compared with the published data based on a rat model to investigate the effect of body size and weight on the organ dose. The calculated and comparison results show that the organ dose conversion coefficients varying the photon energy exhibits similar trend for most organs except for the bone and skin, and the organ dose is sensitive to body size and weight at a photon energy approximately <0.1 MeV.

  5. FDTD calculations of SAR for child voxel models in different postures between 10 MHz and 3 GHz.

    Science.gov (United States)

    Findlay, R P; Lee, A-K; Dimbylow, P J

    2009-08-01

    Calculations of specific energy absorption rate (SAR) have been performed on the rescaled NORMAN 7-y-old voxel model and the Electronics and Telecommunications Research Institute (ETRI) child 7-y-old voxel model in the standing arms down, arms up and sitting postures. These calculations were for plane-wave exposure under isolated and grounded conditions between 10 MHz and 3 GHz. It was found that there was little difference at each resonant frequency between the whole-body averaged SAR values calculated for the NORMAN and ETRI 7-y-old models for each of the postures studied. However, when compared with the arms down posture, raising the arms increased the SAR by up to 25%. Electric field values required to produce the International Commission on Non-Ionizing Radiation Protection and Institute of Electrical and Electronic Engineers public basic restriction were calculated, and compared with reference levels for the different child models and postures. These showed that, under certain worst-case exposure conditions, the reference levels may not be conservative.

  6. TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J; Wu, Q.J.; Yin, F; Kirkpatrick, J; Cabrera, A [Duke University Medical Center, Durham, NC (United States); Ge, Y [University of North Carolina at Charlotte, Charlotte, NC (United States)

    2014-06-15

    Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH

  7. TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

    International Nuclear Information System (INIS)

    Liu, J; Wu, Q.J.; Yin, F; Kirkpatrick, J; Cabrera, A; Ge, Y

    2014-01-01

    Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH

  8. Development of pregnant female, hybrid voxel-mathematical models and their application to the dosimetry of applied magnetic and electric fields at 50 Hz

    International Nuclear Information System (INIS)

    Dimbylow, Peter

    2006-01-01

    This paper describes the development of 2 mm resolution hybrid voxel-mathematical models of the pregnant female. Mathematical models of the developing foetus at 8-, 13-, 26- and 38-weeks of gestation were converted into voxels and combined with the adult female model, NAOMI. This set of models was used to calculate induced current densities and electric fields in the foetus from applied 50 Hz magnetic and electric fields. The influence of foetal tissue conductivities was investigated and implications for electromagnetic field guidelines discussed

  9. A radioactive seed implant on a rabbit's liver following a voxel model representation for dosimetric proposals

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio P.R.; Andrade, Joao Paulo Lopes de; Costa, Igor Temponi; Teixeira, Cleuza H. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg

    2005-07-01

    Animal models have been used in experimentation with ionizing radiation. The evaluation of the energy absorbed per unit tissue mass in vivo transported by nuclear particles is a task to be performed before experimentation. Stochastic or deterministic methodology can be applied, however the dosimetric protocols applied in radiotherapy center cannot be applied directly due to the inherent small geometry and chemical composition of the animal distinct from human. The present article addresses a method in development that will predict the dose distribution into the rabbit thorax based on the solution of the transport phenomena in a voxel model. The model will be applied to simulate a seed implant experiment on a rabbit. Herein, the construction of the three-dimensional voxel model anthropomorphic -anthropometrics to the rabbit is presented. The model is assembling from a set of computer tomography of the rabbit. The computational phantom of the thorax starts at the digitalisation of the CT images, tissue definition, and color image representation of each tissue and organ. The chemical composition and mass density of each tissue is evaluated as similar date presented by ICRU-44. To treat the images, a code namely SISCODES, developed in house, was used. The in vivo experiment that will be simulated is also described. That is a implant of five seeds of 1.6x2 mm performed in a rabbit's liver. The perspective of this work is the application of the model in dosimetric studies predicting the dose distribution around the seed's implanted in vivo experiments. (author)

  10. Self-Esteem and Delinquency in South Korean Adolescents: Latent Growth Modeling

    Science.gov (United States)

    Lee, Kyungeun; Lee, Julie

    2012-01-01

    This study examined the inter-related development of self-esteem and delinquency across three years. Participants were 3449 Korean high school adolescents (age M = 15.8, SD = 0.42, 1725 boys, 1724 girls) from Korea Youth Panel Study (KYPS), in 2005-2007, nationally representative of Korean adolescents. Latent growth modeling was employed for…

  11. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Petoussi-Henss, N

    2007-01-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360 deg. rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%

  12. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    Science.gov (United States)

    Schlattl, H.; Zankl, M.; Petoussi-Henss, N.

    2007-04-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

  13. Intra-voxel heterogeneity influences the dose prescription for dose-painting with radiotherapy: a modelling study

    NARCIS (Netherlands)

    Petit, S.F.; Dekker, A.L.A.J.; Seigneuric, R.; Murrer, L.H.P.; Riel, van N.A.W.; Nordsmark, M.; Overgaard, J.; Lambin, Ph.; Wouters, B.G.

    2009-01-01

    The purpose of this study was to increase the potential of dose redistribution by incorporating estimates of oxygen heterogeneity within imaging voxels for optimal dose determination. Cellular oxygen tension (pO2) distributions were estimated for imaging-size-based voxels by solving oxygen

  14. Lithological, grain-size and architectural trends in the holocene Rhine-Meuse delta-insights from 3D voxel models

    NARCIS (Netherlands)

    Stafleu, J.; Busschers, F.S.

    2014-01-01

    TNO Geological Survey of the Netherlands systematically produces 3D voxel models for answering subsurface related questions. The unique combination of vast amounts of borehole data and the voxelbased approach makes the models valuable new sources for exploring the Quaternary fluvial record. The

  15. Proportion-corrected scaled voxel models for Japanese children and their application to the numerical dosimetry of specific absorption rate for frequencies from 30 MHz to 3 GHz

    International Nuclear Information System (INIS)

    Nagaoka, Tomoaki; Watanabe, Soichi; Kunieda, Etsuo

    2008-01-01

    The development of high-resolution anatomical voxel models of children is difficult given, inter alia, the ethical limitations on subjecting children to medical imaging. We instead used an existing voxel model of a Japanese adult and three-dimensional deformation to develop three voxel models that match the average body proportions of Japanese children at 3, 5 and 7 years old. The adult model was deformed to match the proportions of a child by using the measured dimensions of various body parts of children at 3, 5 and 7 years old and a free-form deformation technique. The three developed models represent average-size Japanese children of the respective ages. They consist of cubic voxels (2 mm on each side) and are segmented into 51 tissues and organs. We calculated the whole-body-averaged specific absorption rates (WBA-SARs) and tissue-averaged SARs for the child models for exposures to plane waves from 30 MHz to 3 GHz; these results were then compared with those for scaled down adult models. We also determined the incident electric-field strength required to produce the exposure equivalent to the ICNIRP basic restriction for general public exposure, i.e., a WBA-SAR of 0.08 W kg -1 .

  16. Verification of the VEF photon beam model for dose calculations by the voxel-Monte-Carlo-algorithm

    International Nuclear Information System (INIS)

    Kriesen, S.; Fippel, M.

    2005-01-01

    The VEF linac head model (VEF, virtual energy fluence) was developed at the University of Tuebingen to determine the primary fluence for calculations of dose distributions in patients by the Voxel-Monte-Carlo-Algorithm (XVMC). This analytical model can be fitted to any therapy accelerator head by measuring only a few basic dose data; therefore, time-consuming Monte-Carlo simulations of the linac head become unnecessary. The aim of the present study was the verification of the VEF model by means of water-phantom measurements, as well as the comparison of this system with a common analytical linac head model of a commercial planning system (TMS, formerly HELAX or MDS Nordion, respectively). The results show that both the VEF and the TMS models can very well simulate the primary fluence. However, the VEF model proved superior in the simulations of scattered radiation and in the calculations of strongly irregular MLC fields. Thus, an accurate and clinically practicable tool for the determination of the primary fluence for Monte-Carlo-Simulations with photons was established, especially for the use in IMRT planning. (orig.)

  17. [Verification of the VEF photon beam model for dose calculations by the Voxel-Monte-Carlo-Algorithm].

    Science.gov (United States)

    Kriesen, Stephan; Fippel, Matthias

    2005-01-01

    The VEF linac head model (VEF, virtual energy fluence) was developed at the University of Tübingen to determine the primary fluence for calculations of dose distributions in patients by the Voxel-Monte-Carlo-Algorithm (XVMC). This analytical model can be fitted to any therapy accelerator head by measuring only a few basic dose data; therefore, time-consuming Monte-Carlo simulations of the linac head become unnecessary. The aim of the present study was the verification of the VEF model by means of water-phantom measurements, as well as the comparison of this system with a common analytical linac head model of a commercial planning system (TMS, formerly HELAX or MDS Nordion, respectively). The results show that both the VEF and the TMS models can very well simulate the primary fluence. However, the VEF model proved superior in the simulations of scattered radiation and in the calculations of strongly irregular MLC fields. Thus, an accurate and clinically practicable tool for the determination of the primary fluence for Monte-Carlo-Simulations with photons was established, especially for the use in IMRT planning.

  18. Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry

    International Nuclear Information System (INIS)

    Nagaoka, Tomoaki; Watanabe, Soichi; Sakurai, Kiyoko; Kunieda, Etsuo; Watanabe, Satoshi; Taki, Masao; Yamanaka, Yukio

    2004-01-01

    With advances in computer performance, the use of high-resolution voxel models of the entire human body has become more frequent in numerical dosimetries of electromagnetic waves. Using magnetic resonance imaging, we have developed realistic high-resolution whole-body voxel models for Japanese adult males and females of average height and weight. The developed models consist of cubic voxels of 2 mm on each side; the models are segmented into 51 anatomic regions. The adult female model is the first of its kind in the world and both are the first Asian voxel models (representing average Japanese) that enable numerical evaluation of electromagnetic dosimetry at high frequencies of up to 3 GHz. In this paper, we will also describe the basic SAR characteristics of the developed models for the VHF/UHF bands, calculated using the finite-difference time-domain method

  19. Computer-assisted segmentation of CT images by statistical region merging for the production of voxel models of anatomy for CT dosimetry

    Czech Academy of Sciences Publication Activity Database

    Caon, M.; Sedlář, Jiří; Bajger, M.; Lee, G.

    2014-01-01

    Roč. 37, č. 2 (2014), s. 393-403 ISSN 0158-9938 Institutional support: RVO:67985556 Keywords : Voxel model * Image segmentation * Statistical region merging * CT dosimetry Subject RIV: JD - Computer Applications, Robotics Impact factor: 0.882, year: 2014 http://library.utia.cas.cz/separaty/2014/ZOI/sedlar-0428537.pdf

  20. Prediction of plasma-induced damage distribution during silicon nitride etching using advanced three-dimensional voxel model

    Energy Technology Data Exchange (ETDEWEB)

    Kuboi, Nobuyuki, E-mail: Nobuyuki.Kuboi@jp.sony.com; Tatsumi, Tetsuya; Kinoshita, Takashi; Shigetoshi, Takushi; Fukasawa, Masanaga; Komachi, Jun; Ansai, Hisahiro [Device and Material Research Group, RDS Platform, Sony Corporation, 4-14-1 Asahi-cho, Atsugi, Kanagawa 243-0014 (Japan)

    2015-11-15

    The authors modeled SiN film etching with hydrofluorocarbon (CH{sub x}F{sub y}/Ar/O{sub 2}) plasma considering physical (ion bombardment) and chemical reactions in detail, including the reactivity of radicals (C, F, O, N, and H), the area ratio of Si dangling bonds, the outflux of N and H, the dependence of the H/N ratio on the polymer layer, and generation of by-products (HCN, C{sub 2}N{sub 2}, NH, HF, OH, and CH, in addition to CO, CF{sub 2}, SiF{sub 2}, and SiF{sub 4}) as ion assistance process parameters for the first time. The model was consistent with the measured C-F polymer layer thickness, etch rate, and selectivity dependence on process variation for SiN, SiO{sub 2}, and Si film etching. To analyze the three-dimensional (3D) damage distribution affected by the etched profile, the authors developed an advanced 3D voxel model that can predict the time-evolution of the etched profile and damage distribution. The model includes some new concepts for gas transportation in the pattern using a fluid model and the property of voxels called “smart voxels,” which contain details of the history of the etching situation. Using this 3D model, the authors demonstrated metal–oxide–semiconductor field-effect transistor SiN side-wall etching that consisted of the main-etch step with CF{sub 4}/Ar/O{sub 2} plasma and an over-etch step with CH{sub 3}F/Ar/O{sub 2} plasma under the assumption of a realistic process and pattern size. A large amount of Si damage induced by irradiated hydrogen occurred in the source/drain region, a Si recess depth of 5 nm was generated, and the dislocated Si was distributed in a 10 nm deeper region than the Si recess, which was consistent with experimental data for a capacitively coupled plasma. An especially large amount of Si damage was also found at the bottom edge region of the metal–oxide–semiconductor field-effect transistors. Furthermore, our simulation results for bulk fin-type field-effect transistor side-wall etching

  1. A computer-simulation study on the effects of MRI voxel dimensions on carotid plaque lipid-core and fibrous cap segmentation and stress modeling.

    Directory of Open Access Journals (Sweden)

    Harm A Nieuwstadt

    Full Text Available The benefits of a decreased slice thickness and/or in-plane voxel size in carotid MRI for atherosclerotic plaque component quantification accuracy and biomechanical peak cap stress analysis have not yet been investigated in detail because of practical limitations.In order to provide a methodology that allows such an investigation in detail, numerical simulations of a T1-weighted, contrast-enhanced, 2D MRI sequence were employed. Both the slice thickness (2 mm, 1 mm, and 0.5 mm and the in plane acquired voxel size (0.62x0.62 mm2 and 0.31x0.31 mm2 were varied. This virtual MRI approach was applied to 8 histology-based 3D patient carotid atherosclerotic plaque models.A decreased slice thickness did not result in major improvements in lumen, vessel wall, and lipid-rich necrotic core size measurements. At 0.62x0.62 mm2 in-plane, only a 0.5 mm slice thickness resulted in improved minimum fibrous cap thickness measurements (a 2-3 fold reduction in measurement error and only marginally improved peak cap stress computations. Acquiring voxels of 0.31x0.31 mm2 in-plane, however, led to either similar or significantly larger improvements in plaque component quantification and computed peak cap stress.This study provides evidence that for currently-used 2D carotid MRI protocols, a decreased slice thickness might not be more beneficial for plaque measurement accuracy than a decreased in-plane voxel size. The MRI simulations performed indicate that not a reduced slice thickness (i.e. more isotropic imaging, but the acquisition of anisotropic voxels with a relatively smaller in-plane voxel size could improve carotid plaque quantification and computed peak cap stress accuracy.

  2. VoxelStats: A MATLAB Package for Multi-Modal Voxel-Wise Brain Image Analysis.

    Science.gov (United States)

    Mathotaarachchi, Sulantha; Wang, Seqian; Shin, Monica; Pascoal, Tharick A; Benedet, Andrea L; Kang, Min Su; Beaudry, Thomas; Fonov, Vladimir S; Gauthier, Serge; Labbe, Aurélie; Rosa-Neto, Pedro

    2016-01-01

    In healthy individuals, behavioral outcomes are highly associated with the variability on brain regional structure or neurochemical phenotypes. Similarly, in the context of neurodegenerative conditions, neuroimaging reveals that cognitive decline is linked to the magnitude of atrophy, neurochemical declines, or concentrations of abnormal protein aggregates across brain regions. However, modeling the effects of multiple regional abnormalities as determinants of cognitive decline at the voxel level remains largely unexplored by multimodal imaging research, given the high computational cost of estimating regression models for every single voxel from various imaging modalities. VoxelStats is a voxel-wise computational framework to overcome these computational limitations and to perform statistical operations on multiple scalar variables and imaging modalities at the voxel level. VoxelStats package has been developed in Matlab(®) and supports imaging formats such as Nifti-1, ANALYZE, and MINC v2. Prebuilt functions in VoxelStats enable the user to perform voxel-wise general and generalized linear models and mixed effect models with multiple volumetric covariates. Importantly, VoxelStats can recognize scalar values or image volumes as response variables and can accommodate volumetric statistical covariates as well as their interaction effects with other variables. Furthermore, this package includes built-in functionality to perform voxel-wise receiver operating characteristic analysis and paired and unpaired group contrast analysis. Validation of VoxelStats was conducted by comparing the linear regression functionality with existing toolboxes such as glim_image and RMINC. The validation results were identical to existing methods and the additional functionality was demonstrated by generating feature case assessments (t-statistics, odds ratio, and true positive rate maps). In summary, VoxelStats expands the current methods for multimodal imaging analysis by allowing the

  3. Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body

    International Nuclear Information System (INIS)

    Findlay, R P; Dimbylow, P J

    2005-01-01

    A change in the posture of the human body can significantly affect the way in which it absorbs radiofrequency electromagnetic radiation. To study this, an anatomically realistic model of the body has been modified to develop new voxel models in postures other than the standard standing position with arms to the side. These postures were sitting, arms stretched out horizontally to the side and vertically above the head. Finite-difference time-domain (FDTD) calculations of the whole-body averaged specific energy absorption rate (SAR) have been performed from 10 MHz to 300 MHz at a resolution of 4 mm. Calculations show that the effect of a raised arm above the head posture was to increase the value of the whole-body averaged SAR at resonance by up to 35% when compared to the standard, arms by the side position. SAR values, both whole-body averaged and localized in the ankle, were used to derive the external electric field values required to produce the SAR basic restrictions of the ICNIRP guidelines. It was found that, in certain postures, external electric field reference levels alone would not provide a conservative estimate of localized SAR exposure and it would be necessary to invoke secondary reference levels on limb currents to provide compliance with restrictions

  4. Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body

    Science.gov (United States)

    Findlay, R. P.; Dimbylow, P. J.

    2005-08-01

    A change in the posture of the human body can significantly affect the way in which it absorbs radiofrequency electromagnetic radiation. To study this, an anatomically realistic model of the body has been modified to develop new voxel models in postures other than the standard standing position with arms to the side. These postures were sitting, arms stretched out horizontally to the side and vertically above the head. Finite-difference time-domain (FDTD) calculations of the whole-body averaged specific energy absorption rate (SAR) have been performed from 10 MHz to 300 MHz at a resolution of 4 mm. Calculations show that the effect of a raised arm above the head posture was to increase the value of the whole-body averaged SAR at resonance by up to 35% when compared to the standard, arms by the side position. SAR values, both whole-body averaged and localized in the ankle, were used to derive the external electric field values required to produce the SAR basic restrictions of the ICNIRP guidelines. It was found that, in certain postures, external electric field reference levels alone would not provide a conservative estimate of localized SAR exposure and it would be necessary to invoke secondary reference levels on limb currents to provide compliance with restrictions.

  5. Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, R P; Dimbylow, P J [National Radiological Protection Board, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2005-08-21

    A change in the posture of the human body can significantly affect the way in which it absorbs radiofrequency electromagnetic radiation. To study this, an anatomically realistic model of the body has been modified to develop new voxel models in postures other than the standard standing position with arms to the side. These postures were sitting, arms stretched out horizontally to the side and vertically above the head. Finite-difference time-domain (FDTD) calculations of the whole-body averaged specific energy absorption rate (SAR) have been performed from 10 MHz to 300 MHz at a resolution of 4 mm. Calculations show that the effect of a raised arm above the head posture was to increase the value of the whole-body averaged SAR at resonance by up to 35% when compared to the standard, arms by the side position. SAR values, both whole-body averaged and localized in the ankle, were used to derive the external electric field values required to produce the SAR basic restrictions of the ICNIRP guidelines. It was found that, in certain postures, external electric field reference levels alone would not provide a conservative estimate of localized SAR exposure and it would be necessary to invoke secondary reference levels on limb currents to provide compliance with restrictions.

  6. Dosimetric study to voxel model applied to cardiac exams in Nuclear medicine

    International Nuclear Information System (INIS)

    Cassola, V.F.; Silva, A.M. Marques da; Hoff, G.

    2008-01-01

    The objective of this study is to analyze the dosimetry in a simplified model of the region of interest of myocardial perfusion studies considering different descriptions of Tc-99m emission spectra. It aims to assess the implications of these different approaches in the description of Tc-99m spectrum, as well as their dosimetric implications

  7. Development of a computational system for radiotherapic planning with the IMRT technique applied to the MCNP computer code with 3D graphic interface for voxel models

    International Nuclear Information System (INIS)

    Fonseca, Telma Cristina Ferreira

    2009-01-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced treatment technique used worldwide in oncology medicine branch. On this master proposal was developed a software package for simulating the IMRT protocol, namely SOFT-RT which attachment the research group 'Nucleo de Radiacoes Ionizantes' - NRI at UFMG. The computational system SOFT-RT allows producing the absorbed dose simulation of the radiotherapic treatment through a three-dimensional voxel model of the patient. The SISCODES code, from NRI, research group, helps in producing the voxel model of the interest region from a set of CT or MRI digitalized images. The SOFT-RT allows also the rotation and translation of the model about the coordinate system axis for better visualization of the model and the beam. The SOFT-RT collects and exports the necessary parameters to MCNP code which will carry out the nuclear radiation transport towards the tumor and adjacent healthy tissues for each orientation and position of the beam planning. Through three-dimensional visualization of voxel model of a patient, it is possible to focus on a tumoral region preserving the whole tissues around them. It takes in account where exactly the radiation beam passes through, which tissues are affected and how much dose is applied in both tissues. The Out-module from SOFT-RT imports the results and express the dose response superimposing dose and voxel model in gray scale in a three-dimensional graphic representation. The present master thesis presents the new computational system of radiotherapic treatment - SOFT-RT code which has been developed using the robust and multi-platform C ++ programming language with the OpenGL graphics packages. The Linux operational system was adopted with the goal of running it in an open source platform and free access. Preliminary simulation results for a cerebral tumor case will be reported as well as some dosimetric evaluations. (author)

  8. A Korean radioecology model to simulate radionuclide behavior in agricultural ecosystems following a nuclear emergency and its application to countermeasures

    International Nuclear Information System (INIS)

    Hwang, W.T.; Suh, K.S.; Kim, E.H.; Han, M.H.; Lee, H.S.; Lee, C.W.

    2003-01-01

    A Korean radioecology model to simulate radionuclide behavior in agricultural ecosystems has been developed as a module for evaluating the ingestion dose in a Korean real-time dose assessment system FADAS, which evaluates the comprehensive radiological consequences in an accidental release of radionuclides to the environment. Using the predictive results of a Korean radioecology model, a methodology for the optimization of countermeasures has been designed based on a cost-benefit analysis. In this manuscript, a Korean radioecology model including agricultural countermeasures was introduced, and discussed with the sample calculations for the postulated accidental release of radionuclides to the environment. (author)

  9. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Science.gov (United States)

    Nada, Rania M; Maal, Thomas J J; Breuning, K Hero; Bergé, Stefaan J; Mostafa, Yehya A; Kuijpers-Jagtman, Anne Marie

    2011-02-09

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  10. FDTD calculations of specific energy absorption rate in a seated voxel model of the human body from 10 MHz to 3 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, R P; Dimbylow, P J [Health Protection Agency, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2006-05-07

    Finite-difference time-domain (FDTD) calculations have been performed to investigate the frequency dependence of the specific energy absorption rate (SAR) in a seated voxel model of the human body. The seated model was derived from NORMAN (NORmalized MAN), an anatomically realistic voxel phantom in the standing posture with arms to the side. Exposure conditions included both vertically and horizontally polarized plane wave electric fields between 10 MHz and 3 GHz. The resolution of the voxel model was 4 mm for frequencies up to 360 MHz and 2 mm for calculations in the higher frequency range. The reduction in voxel size permitted the calculation of SAR at these higher frequencies using the FDTD method. SAR values have been calculated for the seated adult phantom and scaled versions representing 10-, 5- and 1-year-old children under isolated and grounded conditions. These scaled models do not exactly reproduce the dimensions and anatomy of children, but represent good geometric information for a seated child. Results show that, when the field is vertically polarized, the sitting position causes a second, smaller resonance condition not seen in resonance curves for the phantom in the standing posture. This occurs at {approx}130 MHz for the adult model when grounded. Partial-body SAR calculations indicate that the upper and lower regions of the body have their own resonant frequency at {approx}120 MHz and {approx}160 MHz, respectively, when the grounded adult model is orientated in the sitting position. These combine to produce this second resonance peak in the whole-body averaged SAR values calculated. Two resonance peaks also occur for the sitting posture when the incident electric field is horizontally polarized. For the adult model, the peaks in the whole-body averaged SAR occur at {approx}180 and {approx}600 MHz. These peaks are due to resonance in the arms and feet, respectively. Layer absorption plots and colour images of SAR in individual voxels show the

  11. FDTD calculations of specific energy absorption rate in a seated voxel model of the human body from 10 MHz to 3 GHz

    International Nuclear Information System (INIS)

    Findlay, R P; Dimbylow, P J

    2006-01-01

    Finite-difference time-domain (FDTD) calculations have been performed to investigate the frequency dependence of the specific energy absorption rate (SAR) in a seated voxel model of the human body. The seated model was derived from NORMAN (NORmalized MAN), an anatomically realistic voxel phantom in the standing posture with arms to the side. Exposure conditions included both vertically and horizontally polarized plane wave electric fields between 10 MHz and 3 GHz. The resolution of the voxel model was 4 mm for frequencies up to 360 MHz and 2 mm for calculations in the higher frequency range. The reduction in voxel size permitted the calculation of SAR at these higher frequencies using the FDTD method. SAR values have been calculated for the seated adult phantom and scaled versions representing 10-, 5- and 1-year-old children under isolated and grounded conditions. These scaled models do not exactly reproduce the dimensions and anatomy of children, but represent good geometric information for a seated child. Results show that, when the field is vertically polarized, the sitting position causes a second, smaller resonance condition not seen in resonance curves for the phantom in the standing posture. This occurs at ∼130 MHz for the adult model when grounded. Partial-body SAR calculations indicate that the upper and lower regions of the body have their own resonant frequency at ∼120 MHz and ∼160 MHz, respectively, when the grounded adult model is orientated in the sitting position. These combine to produce this second resonance peak in the whole-body averaged SAR values calculated. Two resonance peaks also occur for the sitting posture when the incident electric field is horizontally polarized. For the adult model, the peaks in the whole-body averaged SAR occur at ∼180 and ∼600 MHz. These peaks are due to resonance in the arms and feet, respectively. Layer absorption plots and colour images of SAR in individual voxels show the specific regions in which the

  12. Human-model hybrid Korean air quality forecasting system.

    Science.gov (United States)

    Chang, Lim-Seok; Cho, Ara; Park, Hyunju; Nam, Kipyo; Kim, Deokrae; Hong, Ji-Hyoung; Song, Chang-Keun

    2016-09-01

    The Korean national air quality forecasting system, consisting of the Weather Research and Forecasting, the Sparse Matrix Operator Kernel Emissions, and the Community Modeling and Analysis (CMAQ), commenced from August 31, 2013 with target pollutants of particulate matters (PM) and ozone. Factors contributing to PM forecasting accuracy include CMAQ inputs of meteorological field and emissions, forecasters' capacity, and inherent CMAQ limit. Four numerical experiments were conducted including two global meteorological inputs from the Global Forecast System (GFS) and the Unified Model (UM), two emissions from the Model Intercomparison Study Asia (MICS-Asia) and the Intercontinental Chemical Transport Experiment (INTEX-B) for the Northeast Asia with Clear Air Policy Support System (CAPSS) for South Korea, and data assimilation of the Monitoring Atmospheric Composition and Climate (MACC). Significant PM underpredictions by using both emissions were found for PM mass and major components (sulfate and organic carbon). CMAQ predicts PM2.5 much better than PM10 (NMB of PM2.5: -20~-25%, PM10: -43~-47%). Forecasters' error usually occurred at the next day of high PM event. Once CMAQ fails to predict high PM event the day before, forecasters are likely to dismiss the model predictions on the next day which turns out to be true. The best combination of CMAQ inputs is the set of UM global meteorological field, MICS-Asia and CAPSS 2010 emissions with the NMB of -12.3%, the RMSE of 16.6μ/m(3) and the R(2) of 0.68. By using MACC data as an initial and boundary condition, the performance skill of CMAQ would be improved, especially in the case of undefined coarse emission. A variety of methods such as ensemble and data assimilation are considered to improve further the accuracy of air quality forecasting, especially for high PM events to be comparable to for all cases. The growing utilization of the air quality forecast induced the public strongly to demand that the accuracy of the

  13. Voxel-based statistical analysis of cerebral glucose metabolism in the rat cortical deafness model by 3D reconstruction of brain from autoradiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Sung; Park, Kwang Suk [Seoul National University College of Medicine, Department of Nuclear Medicine, 28 Yungun-Dong, Chongno-Ku, Seoul (Korea); Seoul National University College of Medicine, Department of Biomedical Engineering, Seoul (Korea); Ahn, Soon-Hyun; Oh, Seung Ha; Kim, Chong Sun; Chung, June-Key; Lee, Myung Chul [Seoul National University College of Medicine, Department of Otolaryngology, Head and Neck Surgery, Seoul (Korea); Lee, Dong Soo; Jeong, Jae Min [Seoul National University College of Medicine, Department of Nuclear Medicine, 28 Yungun-Dong, Chongno-Ku, Seoul (Korea)

    2005-06-01

    Animal models of cortical deafness are essential for investigation of the cerebral glucose metabolism in congenital or prelingual deafness. Autoradiographic imaging is mainly used to assess the cerebral glucose metabolism in rodents. In this study, procedures for the 3D voxel-based statistical analysis of autoradiographic data were established to enable investigations of the within-modal and cross-modal plasticity through entire areas of the brain of sensory-deprived animals without lumping together heterogeneous subregions within each brain structure into a large region of interest. Thirteen 2-[1-{sup 14}C]-deoxy-D-glucose autoradiographic images were acquired from six deaf and seven age-matched normal rats (age 6-10 weeks). The deafness was induced by surgical ablation. For the 3D voxel-based statistical analysis, brain slices were extracted semiautomatically from the autoradiographic images, which contained the coronal sections of the brain, and were stacked into 3D volume data. Using principal axes matching and mutual information maximization algorithms, the adjacent coronal sections were co-registered using a rigid body transformation, and all sections were realigned to the first section. A study-specific template was composed and the realigned images were spatially normalized onto the template. Following count normalization, voxel-wise t tests were performed to reveal the areas with significant differences in cerebral glucose metabolism between the deaf and the control rats. Continuous and clear edges were detected in each image after registration between the coronal sections, and the internal and external landmarks extracted from the spatially normalized images were well matched, demonstrating the reliability of the spatial processing procedures. Voxel-wise t tests showed that the glucose metabolism in the bilateral auditory cortices of the deaf rats was significantly (P<0.001) lower than that in the controls. There was no significantly reduced metabolism in

  14. Voxel-based statistical analysis of cerebral glucose metabolism in the rat cortical deafness model by 3D reconstruction of brain from autoradiographic images

    International Nuclear Information System (INIS)

    Lee, Jae Sung; Park, Kwang Suk; Ahn, Soon-Hyun; Oh, Seung Ha; Kim, Chong Sun; Chung, June-Key; Lee, Myung Chul; Lee, Dong Soo; Jeong, Jae Min

    2005-01-01

    Animal models of cortical deafness are essential for investigation of the cerebral glucose metabolism in congenital or prelingual deafness. Autoradiographic imaging is mainly used to assess the cerebral glucose metabolism in rodents. In this study, procedures for the 3D voxel-based statistical analysis of autoradiographic data were established to enable investigations of the within-modal and cross-modal plasticity through entire areas of the brain of sensory-deprived animals without lumping together heterogeneous subregions within each brain structure into a large region of interest. Thirteen 2-[1- 14 C]-deoxy-D-glucose autoradiographic images were acquired from six deaf and seven age-matched normal rats (age 6-10 weeks). The deafness was induced by surgical ablation. For the 3D voxel-based statistical analysis, brain slices were extracted semiautomatically from the autoradiographic images, which contained the coronal sections of the brain, and were stacked into 3D volume data. Using principal axes matching and mutual information maximization algorithms, the adjacent coronal sections were co-registered using a rigid body transformation, and all sections were realigned to the first section. A study-specific template was composed and the realigned images were spatially normalized onto the template. Following count normalization, voxel-wise t tests were performed to reveal the areas with significant differences in cerebral glucose metabolism between the deaf and the control rats. Continuous and clear edges were detected in each image after registration between the coronal sections, and the internal and external landmarks extracted from the spatially normalized images were well matched, demonstrating the reliability of the spatial processing procedures. Voxel-wise t tests showed that the glucose metabolism in the bilateral auditory cortices of the deaf rats was significantly (P<0.001) lower than that in the controls. There was no significantly reduced metabolism in any

  15. The Wheel Model of STEAM Education Based on Traditional Korean Scientific Contents

    Science.gov (United States)

    Kim, Pyoung Won

    2016-01-01

    The Korean STEAM education pursues a convergent human resources education, but there are shortcomings associated with it due to the fact that it excludes the Humanities in its curriculum. This study embodies the accomplishments from the design and field application of the STEAM education model that has added Humanities fields (history, geography,…

  16. Understanding Korean Transnational Girls in High School Science Classes: Beyond the Model Minority Stereotype

    Science.gov (United States)

    Ryu, Minjung

    2015-01-01

    This study examines six Korean transnational girls enrolled in two advanced placement (AP) biology classes to understand their experiences in science classrooms at the intersection of race, language, and gender. Confronting the model minority stereotype for Asian students, which is particularly salient in science, technology, engineering, and…

  17. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches.

    Directory of Open Access Journals (Sweden)

    Rania M Nada

    Full Text Available Superimposition of serial Cone Beam Computed Tomography (CBCT scans has become a valuable tool for three dimensional (3D assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16 for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27 for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.

  18. Structural Breaks and Long Memory Property in Korean Won Exchange Rates: Adaptive FIGARCH Model

    Directory of Open Access Journals (Sweden)

    Young Wook Han

    2011-06-01

    Full Text Available This paper explores the issue of structural breaks and long memory property in the conditional variance process of the Korean exchange rates. To analyze the above in detail, this paper examines the dynamics of the structural breaks and the long memory in the conditional variance process of the Korean exchange returns by using the daily KRW-USD and KRW-JPY exchange rates for the period from 2000 through 2007. In particular, this paper employs the Adaptive FIGARCH model of Baillie and Morana (2009 which account for the structural breaks and the long memory property together. This paper also finds that the new Adaptive FIGARCH model outperforms the usual FIGARCH model of Baillie et al. (1996 when the structural breaks are present and that the long memory property in the conditional variance process of the Korean exchange returns is significantly reduced after the structural breaks are accounted for. Thus, these results suggest that the upward biased long memory property observed in the conditional variance process of the Korean exchange returns could partially have been imparted as a result of neglecting the structural breaks.

  19. Monitoring of human brain functions in risk decision-making task by diffuse optical tomography using voxel-wise general linear model

    Science.gov (United States)

    Lin, Zi-Jing; Li, Lin; Cazzell, Marry; Liu, Hanli

    2013-03-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive imaging technique which measures the hemodynamic changes that reflect the brain activity. Diffuse optical tomography (DOT), a variant of fNIRS with multi-channel NIRS measurements, has demonstrated capability of three dimensional (3D) reconstructions of hemodynamic changes due to the brain activity. Conventional method of DOT image analysis to define the brain activation is based upon the paired t-test between two different states, such as resting-state versus task-state. However, it has limitation because the selection of activation and post-activation period is relatively subjective. General linear model (GLM) based analysis can overcome this limitation. In this study, we combine the 3D DOT image reconstruction with GLM-based analysis (i.e., voxel-wise GLM analysis) to investigate the brain activity that is associated with the risk-decision making process. Risk decision-making is an important cognitive process and thus is an essential topic in the field of neuroscience. The balloon analogue risk task (BART) is a valid experimental model and has been commonly used in behavioral measures to assess human risk taking action and tendency while facing risks. We have utilized the BART paradigm with a blocked design to investigate brain activations in the prefrontal and frontal cortical areas during decision-making. Voxel-wise GLM analysis was performed on 18human participants (10 males and 8females).In this work, we wish to demonstrate the feasibility of using voxel-wise GLM analysis to image and study cognitive functions in response to risk decision making by DOT. Results have shown significant changes in the dorsal lateral prefrontal cortex (DLPFC) during the active choice mode and a different hemodynamic pattern between genders, which are in good agreements with published literatures in functional magnetic resonance imaging (fMRI) and fNIRS studies.

  20. SU-F-BRB-10: A Statistical Voxel Based Normal Organ Dose Prediction Model for Coplanar and Non-Coplanar Prostate Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tran, A; Yu, V; Nguyen, D; Woods, K; Low, D; Sheng, K [UCLA, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Knowledge learned from previous plans can be used to guide future treatment planning. Existing knowledge-based treatment planning methods study the correlation between organ geometry and dose volume histogram (DVH), which is a lossy representation of the complete dose distribution. A statistical voxel dose learning (SVDL) model was developed that includes the complete dose volume information. Its accuracy of predicting volumetric-modulated arc therapy (VMAT) and non-coplanar 4π radiotherapy was quantified. SVDL provided more isotropic dose gradients and may improve knowledge-based planning. Methods: 12 prostate SBRT patients originally treated using two full-arc VMAT techniques were re-planned with 4π using 20 intensity-modulated non-coplanar fields to a prescription dose of 40 Gy. The bladder and rectum voxels were binned based on their distances to the PTV. The dose distribution in each bin was resampled by convolving to a Gaussian kernel, resulting in 1000 data points in each bin that predicted the statistical dose information of a voxel with unknown dose in a new patient without triaging information that may be collectively important to a particular patient. We used this method to predict the DVHs, mean and max doses in a leave-one-out cross validation (LOOCV) test and compared its performance against lossy estimators including mean, median, mode, Poisson and Rayleigh of the voxelized dose distributions. Results: SVDL predicted the bladder and rectum doses more accurately than other estimators, giving mean percentile errors ranging from 13.35–19.46%, 4.81–19.47%, 22.49–28.69%, 23.35–30.5%, 21.05–53.93% for predicting mean, max dose, V20, V35, and V40 respectively, to OARs in both planning techniques. The prediction errors were generally lower for 4π than VMAT. Conclusion: By employing all dose volume information in the SVDL model, the OAR doses were more accurately predicted. 4π plans are better suited for knowledge-based planning than

  1. Voxel based statistical analysis method for microPET studies to assess the cerebral glucose metabolism in cat deafness model: comparison to ROI based method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Su; Lee, Jae Sung; Park, Min Hyun; Lee, Jong Jin; Kang, Hye Jin; Lee, Hyo Jeong; Oh, Seung Ha; Kim, Chong Sun; Jung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lim, Sang Moo [KIRAMS, Seoul (Korea, Republic of)

    2005-07-01

    Imaging research on the brain of sensory-deprived cats using small animal PET scanner has gained interest since the abundant information about the sensory system of ths animal is available and close examination of the brain is possible due to larger size of its brain than mouse or rat. In this study, we have established the procedures for 3D voxel-based statistical analysis (SPM) of FDG PET image of cat brain, and confirmed using ROI based-method. FDG PET scans of 4 normal and 4 deaf cats were acquired for 30 minutes using microPET R4 scanner. Only the brain cortices were extracted using a masking and threshold method to facilitate spatial normalization. After spatial normalization and smoothing, 3D voxel-wise and ROI based t-test were performed to identify the regions with significant different FDG uptake between the normal and deaf cats. In ROI analysis, 26 ROIs were drawn on both hemispheres, and regional mean pixel value in each ROI was normalized to the global mean of the brain. Cat brains were spatially normalized well onto the target brain due to the removal of background activity. When cerebral glucose metabolism of deaf cats were compared to the normal controls after removing the effects of the global count, the glucose metabolism in the auditory cortex, head of caudate nucleus, and thalamus in both hemispheres of the deaf cats was significantly lower than that of the controls (P<0.01). No area showed a significantly increased metabolism in the deaf cats even in higher significance level (P<0.05). ROI analysis also showed significant reduction of glucose metabolism in the same region. This study established and confirmed a method for voxel-based analysis of animal PET data of cat brain, which showed high localization accuracy and specificity and was useful for examining the cerebral glucose metabolism in a cat cortical deafness model.

  2. Voxel based statistical analysis method for microPET studies to assess the cerebral glucose metabolism in cat deafness model: comparison to ROI based method

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Park, Min Hyun; Lee, Jong Jin; Kang, Hye Jin; Lee, Hyo Jeong; Oh, Seung Ha; Kim, Chong Sun; Jung, June Key; Lee, Myung Chul; Lee, Dong Soo; Lim, Sang Moo

    2005-01-01

    Imaging research on the brain of sensory-deprived cats using small animal PET scanner has gained interest since the abundant information about the sensory system of ths animal is available and close examination of the brain is possible due to larger size of its brain than mouse or rat. In this study, we have established the procedures for 3D voxel-based statistical analysis (SPM) of FDG PET image of cat brain, and confirmed using ROI based-method. FDG PET scans of 4 normal and 4 deaf cats were acquired for 30 minutes using microPET R4 scanner. Only the brain cortices were extracted using a masking and threshold method to facilitate spatial normalization. After spatial normalization and smoothing, 3D voxel-wise and ROI based t-test were performed to identify the regions with significant different FDG uptake between the normal and deaf cats. In ROI analysis, 26 ROIs were drawn on both hemispheres, and regional mean pixel value in each ROI was normalized to the global mean of the brain. Cat brains were spatially normalized well onto the target brain due to the removal of background activity. When cerebral glucose metabolism of deaf cats were compared to the normal controls after removing the effects of the global count, the glucose metabolism in the auditory cortex, head of caudate nucleus, and thalamus in both hemispheres of the deaf cats was significantly lower than that of the controls (P<0.01). No area showed a significantly increased metabolism in the deaf cats even in higher significance level (P<0.05). ROI analysis also showed significant reduction of glucose metabolism in the same region. This study established and confirmed a method for voxel-based analysis of animal PET data of cat brain, which showed high localization accuracy and specificity and was useful for examining the cerebral glucose metabolism in a cat cortical deafness model

  3. Detecting phase singularities and rotor center trajectories based on the Hilbert transform of intraatrial electrograms in an atrial voxel model

    Directory of Open Access Journals (Sweden)

    Unger Laura Anna

    2015-09-01

    Full Text Available This work aimed at the detection of rotor centers within the atrial cavity during atrial fibrillation on the basis of phase singularities. A voxel based method was established which employs the Hilbert transform and the phase of unipolar electrograms. The method provides a 3D overview of phase singularities at the endocardial surface and within the blood volume. Mapping those phase singularities from the inside of the atria at the endocardium yielded rotor center trajectories. We discuss the results for an unstable and a more stable rotor. The side length of the areas covered by the trajectories varied from 1.5 mm to 10 mm. These results are important for cardiologists who target rotors with RF ablation in order to cure atrial fibrillation.

  4. Strategies for improving the Voxel-based statistical analysis for animal PET studies: assessment of cerebral glucose metabolism in cat deafness model

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Park, Min Hyun; Kang, Hye Jin; Im, Ki Chun; Moon, Dae Hyuk; Lim, Sang Moo; Oh, Seung Ha; Lee, Dong Soo

    2007-01-01

    In imaging studies of the human brain, voxel-based statistical analysis method was widely used, since these methods were originally developed for the analysis of the human brain data, they are not optimal for the animal brain data. The aim of this study is to optimize the procedures for the 3D voxel-based statistical analysis of cat FDG PET brain images. A microPET Focus 120 scanner was used. Eight cats underwent FDG PET scans twice before and after inducing the deafness. Only the brain and adjacent regions were extracted from each data set by manual masking. Individual PET image at normal and deaf state was realigned to each other to remove the confounding effects by the different spatial normalization parameters on the results of statistical analyses. Distance between the sampling points on the reference image and kernel size of Gaussian filter applied to the images before estimating the realignment parameters were adjusted to 0.5 mm and 2 mm. Both data was then spatial normalized onto study-specific cat brain template. Spatially normalized PET data were smoothed and voxel-based paired t-test was performed. Cerebral glucose metabolism decreased significantly after the loss of hearing capability in parietal lobes, postcentral gyri, STG, MTG, lTG, and IC at both hemisphere and left SC (FDR corrected P < 0.05, k=50). Cerebral glucose metabolism in deaf cats was found to be significantly higher than in controls in the right cingulate (FDR corrected P < 0.05, k=50). The ROI analysis also showed significant reduction of glucose metabolism in the same areas as in the SPM analysis, except for some regions (P < 0.05). Method for the voxel-based analysis of cat brain PET data was optimized for analysis of cat brain PET. This result was also confirmed by ROI analysis. The results obtained demonstrated the high localization accuracy and specificity of the developed method, and were found to be useful for examining cerebral glucose metabolism in a cat cortical deafness model

  5. Strategies for improving the Voxel-based statistical analysis for animal PET studies: assessment of cerebral glucose metabolism in cat deafness model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Su; Lee, Jae Sung; Park, Min Hyun; Kang, Hye Jin; Im, Ki Chun; Moon, Dae Hyuk; Lim, Sang Moo; Oh, Seung Ha; Lee, Dong Soo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    In imaging studies of the human brain, voxel-based statistical analysis method was widely used, since these methods were originally developed for the analysis of the human brain data, they are not optimal for the animal brain data. The aim of this study is to optimize the procedures for the 3D voxel-based statistical analysis of cat FDG PET brain images. A microPET Focus 120 scanner was used. Eight cats underwent FDG PET scans twice before and after inducing the deafness. Only the brain and adjacent regions were extracted from each data set by manual masking. Individual PET image at normal and deaf state was realigned to each other to remove the confounding effects by the different spatial normalization parameters on the results of statistical analyses. Distance between the sampling points on the reference image and kernel size of Gaussian filter applied to the images before estimating the realignment parameters were adjusted to 0.5 mm and 2 mm. Both data was then spatial normalized onto study-specific cat brain template. Spatially normalized PET data were smoothed and voxel-based paired t-test was performed. Cerebral glucose metabolism decreased significantly after the loss of hearing capability in parietal lobes, postcentral gyri, STG, MTG, lTG, and IC at both hemisphere and left SC (FDR corrected P < 0.05, k=50). Cerebral glucose metabolism in deaf cats was found to be significantly higher than in controls in the right cingulate (FDR corrected P < 0.05, k=50). The ROI analysis also showed significant reduction of glucose metabolism in the same areas as in the SPM analysis, except for some regions (P < 0.05). Method for the voxel-based analysis of cat brain PET data was optimized for analysis of cat brain PET. This result was also confirmed by ROI analysis. The results obtained demonstrated the high localization accuracy and specificity of the developed method, and were found to be useful for examining cerebral glucose metabolism in a cat cortical deafness model.

  6. Disaster Reintegration Model: A Qualitative Analysis on Developing Korean Disaster Mental Health Support Model

    Directory of Open Access Journals (Sweden)

    Yun-Jung Choi

    2018-02-01

    Full Text Available This study sought to describe the mental health problems experienced by Korean disaster survivors, using a qualitative research method to provide empirical resources for effective disaster mental health support in Korea. Participants were 16 adults or elderly adults who experienced one or more disasters at least 12 months ago recruited via theoretical sampling. Participants underwent in-depth individual interviews on their disaster experiences, which were recorded and transcribed for qualitative analysis, which followed Strauss and Corbin’s (1998 Grounded theory. After open coding, participants’ experiences were categorized into 130 codes, 43 sub-categories and 17 categories. The categories were further analyzed in a paradigm model, conditional model and the Disaster Reintegration Model, which proposed potentially effective mental health recovery strategies for disaster survivors, health providers and administrators. To provide effective assistance for mental health recovery of disaster survivors, both personal and public resilience should be promoted while considering both cultural and spiritual elements.

  7. Integrated model of Korean spent fuel and high level waste disposal options - 16091

    International Nuclear Information System (INIS)

    Hwang, Yongsoo; Miller, Ian

    2009-01-01

    This paper describes an integrated model developed by the Korean Atomic Energy Research Institute (KAERI) to simulate options for disposal of spent nuclear fuel (SNF) and reprocessing products in South Korea. A companion paper (Hwang and Miller, 2009) describes a systems-level model of Korean options for spent nuclear fuel (SNF) management in the 21. century. The model addresses alternative design concepts for disposal of SNF of different types (Candu, PWR), high level waste, and fission products arising from a variety of alternative fuel cycle back ends. It uses the GoldSim software to simulate the engineered system, near-field and far-field geosphere, and biosphere, resulting in long-term dose predictions for a variety of receptor groups. The model's results allow direct comparison of alternative repository design concepts, and identification of key parameter uncertainties and contributors to receptor doses. (authors)

  8. Assessments of Maize Yield Potential in the Korean Peninsula Using Multiple Crop Models

    Science.gov (United States)

    Kim, S. H.; Myoung, B.; Lim, C. H.; Lee, S. G.; Lee, W. K.; Kafatos, M.

    2015-12-01

    The Korean Peninsular has unique agricultural environments due to the differences in the political and socio-economical systems between the Republic of Korea (SK, hereafter) and the Democratic Peoples' Republic of Korea (NK, hereafter). NK has been suffering from the lack of food supplies caused by natural disasters, land degradation and failed political system. The neighboring developed country SK has a better agricultural system but very low food self-sufficiency rate (around 1% of maize). Maize is an important crop in both countries since it is staple food for NK and SK is No. 2 maize importing country in the world after Japan. Therefore evaluating maize yield potential (Yp) in the two distinct regions is essential to assess food security under climate change and variability. In this study, we have utilized multiple process-based crop models capable of regional-scale assessments to evaluate maize Yp over the Korean Peninsula - the GIS version of EPIC model (GEPIC) and APSIM model that can be expanded to regional scales (APSIM regions). First we evaluated model performance and skill for 20 years from 1991 to 2010 using reanalysis data (Local Data Assimilation and Prediction System (LDAPS); 1.5km resolution) and observed data. Each model's performances were compared over different regions within the Korean Peninsula of different regional climate characteristics. To quantify the major influence of individual climate variables, we also conducted a sensitivity test using 20 years of climatology. Lastly, a multi-model ensemble analysis was performed to reduce crop model uncertainties. The results will provide valuable information for estimating the climate change or variability impacts on Yp over the Korean Peninsula.

  9. Development of a dynamic food chain model DYNACON and its application to Korean agricultural conditions

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Cho, Gyuseong; Han, Moon Hee

    1998-01-01

    A dynamic food chain model DYNACON was developed to simulate the radionuclide transfer on agricultural ecosystems. DYNACON estimates the radioactivity in each compartment of food chains for three radionuclides, nine plant species and five animal products as a function of the deposition date. A number of the parameter values used in this study are representative of Korean agricultural conditions. The model was expressed by coupled differential equations and the radioactivity in each compartment was solved as a function of time following an acute deposition. Although DYNACON is structurally based on existing models, it was designed in order to simulate more realistic radionuclide behavior in Korean agricultural conditions and to save computation time. It was found that the radioactivity in foodstuffs depends strongly on the date of deposition. A comparative study between DYNACON and an equilibrium model showed good agreement for depositions that occur during the growing season of plants. DYNACON is going to be implemented in a Korean real-time dose assessment system FADAS. (author)

  10. Voxel-Based LIDAR Analysis and Applications

    Science.gov (United States)

    Hagstrom, Shea T.

    One of the greatest recent changes in the field of remote sensing is the addition of high-quality Light Detection and Ranging (LIDAR) instruments. In particular, the past few decades have been greatly beneficial to these systems because of increases in data collection speed and accuracy, as well as a reduction in the costs of components. These improvements allow modern airborne instruments to resolve sub-meter details, making them ideal for a wide variety of applications. Because LIDAR uses active illumination to capture 3D information, its output is fundamentally different from other modalities. Despite this difference, LIDAR datasets are often processed using methods appropriate for 2D images and that do not take advantage of its primary virtue of 3-dimensional data. It is this problem we explore by using volumetric voxel modeling. Voxel-based analysis has been used in many applications, especially medical imaging, but rarely in traditional remote sensing. In part this is because the memory requirements are substantial when handling large areas, but with modern computing and storage this is no longer a significant impediment. Our reason for using voxels to model scenes from LIDAR data is that there are several advantages over standard triangle-based models, including better handling of overlapping surfaces and complex shapes. We show how incorporating system position information from early in the LIDAR point cloud generation process allows radiometrically-correct transmission and other novel voxel properties to be recovered. This voxelization technique is validated on simulated data using the Digital Imaging and Remote Sensing Image Generation (DIRSIG) software, a first-principles based ray-tracer developed at the Rochester Institute of Technology. Voxel-based modeling of LIDAR can be useful on its own, but we believe its primary advantage is when applied to problems where simpler surface-based 3D models conflict with the requirement of realistic geometry. To

  11. Estimation model for habitual 24-hour urinary-sodium excretion using simple questionnaires from normotensive Koreans.

    Directory of Open Access Journals (Sweden)

    Ji-Sook Kong

    Full Text Available This study was conducted to develop an equation for estimation of 24-h urinary-sodium excretion that can serve as an alternative to 24-h dietary recall and 24-h urine collection for normotensive Korean adults. In total, data on 640 healthy Korean adults aged 19 to 69 years from 4 regions of the country were collected as a training set. In order to externally validate the equation developed from that training set, 200 subjects were recruited independently as a validation set. Due to heterogeneity by gender, we constructed a gender-specific equation for estimation of 24-h urinary-sodium excretion by using a multivariable linear regression model and assessed the performance of the developed equation in validation set. The best model consisted of age, body weight, dietary behavior ('eating salty food', 'Kimchi consumption', 'Korean soup or stew consumption', 'soy sauce or red pepper paste consumption', and smoking status in men, and age, body weight, dietary behavior ('salt preference', 'eating salty food', 'checking sodium content for processed foods', 'nut consumption', and smoking status in women, respectively. When this model was tested in the external validation set, the mean bias between the measured and estimated 24-h urinary-sodium excretion from Bland-Altman plots was -1.92 (95% CI: -113, 110 mmol/d for men and -1.51 (95% CI: -90.6, 87.6 mmol/d for women. The cut-points of sodium intake calculated based on the equations were ≥4,000 mg/d for men and ≥3,500 mg/d for women, with 89.8 and 76.6% sensitivity and 29.3 and 64.2% specificity, respectively. In this study, a habitual 24-hour urinary-sodium-excretion-estimation model of normotensive Korean adults based on anthropometric and lifestyle factors was developed and showed feasibility for an asymptomatic population.

  12. Development of a computational system for radiotherapic planning with the IMRT technique applied to the MCNP computer code with 3D graphic interface for voxel models; Desenvolvimento de um sistema computacional para o planejamento radioterapico com a tecnica IMRT aplicado ao codigo MCNP com interface grafica 3D para modelos de voxel

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Telma Cristina Ferreira

    2009-07-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced treatment technique used worldwide in oncology medicine branch. On this master proposal was developed a software package for simulating the IMRT protocol, namely SOFT-RT which attachment the research group 'Nucleo de Radiacoes Ionizantes' - NRI at UFMG. The computational system SOFT-RT allows producing the absorbed dose simulation of the radiotherapic treatment through a three-dimensional voxel model of the patient. The SISCODES code, from NRI, research group, helps in producing the voxel model of the interest region from a set of CT or MRI digitalized images. The SOFT-RT allows also the rotation and translation of the model about the coordinate system axis for better visualization of the model and the beam. The SOFT-RT collects and exports the necessary parameters to MCNP code which will carry out the nuclear radiation transport towards the tumor and adjacent healthy tissues for each orientation and position of the beam planning. Through three-dimensional visualization of voxel model of a patient, it is possible to focus on a tumoral region preserving the whole tissues around them. It takes in account where exactly the radiation beam passes through, which tissues are affected and how much dose is applied in both tissues. The Out-module from SOFT-RT imports the results and express the dose response superimposing dose and voxel model in gray scale in a three-dimensional graphic representation. The present master thesis presents the new computational system of radiotherapic treatment - SOFT-RT code which has been developed using the robust and multi-platform C{sup ++} programming language with the OpenGL graphics packages. The Linux operational system was adopted with the goal of running it in an open source platform and free access. Preliminary simulation results for a cerebral tumor case will be reported as well as some dosimetric evaluations. (author)

  13. Development of a computational system for radiotherapic planning with the IMRT technique applied to the MCNP computer code with 3D graphic interface for voxel models; Desenvolvimento de um sistema computacional para o planejamento radioterapico com a tecnica IMRT aplicado ao codigo MCNP com interface grafica 3D para modelos de voxel

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Telma Cristina Ferreira

    2009-07-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced treatment technique used worldwide in oncology medicine branch. On this master proposal was developed a software package for simulating the IMRT protocol, namely SOFT-RT which attachment the research group 'Nucleo de Radiacoes Ionizantes' - NRI at UFMG. The computational system SOFT-RT allows producing the absorbed dose simulation of the radiotherapic treatment through a three-dimensional voxel model of the patient. The SISCODES code, from NRI, research group, helps in producing the voxel model of the interest region from a set of CT or MRI digitalized images. The SOFT-RT allows also the rotation and translation of the model about the coordinate system axis for better visualization of the model and the beam. The SOFT-RT collects and exports the necessary parameters to MCNP code which will carry out the nuclear radiation transport towards the tumor and adjacent healthy tissues for each orientation and position of the beam planning. Through three-dimensional visualization of voxel model of a patient, it is possible to focus on a tumoral region preserving the whole tissues around them. It takes in account where exactly the radiation beam passes through, which tissues are affected and how much dose is applied in both tissues. The Out-module from SOFT-RT imports the results and express the dose response superimposing dose and voxel model in gray scale in a three-dimensional graphic representation. The present master thesis presents the new computational system of radiotherapic treatment - SOFT-RT code which has been developed using the robust and multi-platform C{sup ++} programming language with the OpenGL graphics packages. The Linux operational system was adopted with the goal of running it in an open source platform and free access. Preliminary simulation results for a cerebral tumor case will be reported as well as some dosimetric evaluations. (author)

  14. A Predictive Model on North Korean Refugees' Adaptation to South Korean Society: Resilience in Response to Psychological Trauma

    Directory of Open Access Journals (Sweden)

    So-Hee Lim, PhD

    2016-06-01

    Conclusions: The results suggest that resilience can be improved through self-efficacy. It was the most significant factor decreasing psychological trauma and increasing resilience. Therefore, we need to develop programs for self-efficacy. The results also provide basic data for policy making for North Korean refugees.

  15. Multi Voxel Descriptor for 3D Texture Retrieval

    Directory of Open Access Journals (Sweden)

    Hero Yudo Martono

    2016-08-01

    Full Text Available In this paper, we present a new feature descriptors  which exploit voxels for 3D textured retrieval system when models vary either by geometric shape or texture or both. First, we perform pose normalisation to modify arbitrary 3D models  in order to have same orientation. We then map the structure of 3D models into voxels. This purposes to make all the 3D models have the same dimensions. Through this voxels, we can capture information from a number of ways.  First, we build biner voxel histogram and color voxel histogram.  Second, we compute distance from centre voxel into other voxels and generate histogram. Then we also compute fourier transform in spectral space.  For capturing texture feature, we apply voxel tetra pattern. Finally, we merge all features by linear combination. For experiment, we use standard evaluation measures such as Nearest Neighbor (NN, First Tier (FT, Second Tier (ST, Average Dynamic Recall (ADR. Dataset in SHREC 2014  and its evaluation program is used to verify the proposed method. Experiment result show that the proposed method  is more accurate when compared with some methods of state-of-the-art.

  16. D Textured Modelling of both Exterior and Interior of Korean Styled Architectures

    Science.gov (United States)

    Lee, J.-D.; Bhang, K.-J.; Schuhr, W.

    2017-08-01

    This paper describes 3D modelling procedure of two Korean styled architectures which were performed through a series of processing from data acquired with the terrestrial laser scanner. These two case projects illustate the use of terrestrial laser scanner as a digital documentation tool for management, conservation and restoration of the cultural assets. We showed an approach to automate reconstruction of both the outside and inside models of a building from laser scanning data. Laser scanning technology is much more efficient than existing photogrammetry in measuring shape and constructing spatial database for preservation and restoration of cultural assets as well as for deformation monitoring and safety diagnosis of structures.

  17. 3D TEXTURED MODELLING OF BOTH EXTERIOR AND INTERIOR OF KOREAN STYLED ARCHITECTURES

    Directory of Open Access Journals (Sweden)

    J.-D. Lee

    2017-08-01

    Full Text Available This paper describes 3D modelling procedure of two Korean styled architectures which were performed through a series of processing from data acquired with the terrestrial laser scanner. These two case projects illustate the use of terrestrial laser scanner as a digital documentation tool for management, conservation and restoration of the cultural assets. We showed an approach to automate reconstruction of both the outside and inside models of a building from laser scanning data. Laser scanning technology is much more efficient than existing photogrammetry in measuring shape and constructing spatial database for preservation and restoration of cultural assets as well as for deformation monitoring and safety diagnosis of structures.

  18. Things Korean.

    Science.gov (United States)

    Chang, Roberta

    Presented in this booklet are brief descriptions of items and activities that are symbolic of Korean culture. Some of the items and activities described include traditional Korean clothing and accessories, dolls, fans, a Korean game called "yut," tape recordings of Korean music, a "buhk" (drum), and brass eating utensils. A map of Korea, some…

  19. Development of a claim review and payment model utilizing diagnosis related groups under the Korean health insurance.

    Science.gov (United States)

    Shin, Y S; Yeom, Y K; Hwang, H

    1993-02-01

    This paper describes the development of a claim review and payment model utilizing the diagnosis related groups (DRGs) for the fee for service-based payment system of the Korean health insurance. The present review process, which examines all claims manually on a case-by-case basis, has been considered to be inefficient, costly, and time-consuming. Differences in case mix among hospitals are controlled in the proposed model using the Korean DRGs. They were developed by modifying the US-DRG system. An empirical test of the model indicated that it can enhance the efficiency as well as the credibility and objectivity of the claim review. Furthermore, it is expected that it can contribute effectively to medical cost containments and to optimal practice pattern of hospitals by establishing a useful mechanism in monitoring the performance of hospitals. However, the performance of this model needs to be upgraded by refining the Korean DRGs which play a key role in the model.

  20. Prediction Model for Gastric Cancer Incidence in Korean Population.

    Directory of Open Access Journals (Sweden)

    Bang Wool Eom

    Full Text Available Predicting high risk groups for gastric cancer and motivating these groups to receive regular checkups is required for the early detection of gastric cancer. The aim of this study is was to develop a prediction model for gastric cancer incidence based on a large population-based cohort in Korea.Based on the National Health Insurance Corporation data, we analyzed 10 major risk factors for gastric cancer. The Cox proportional hazards model was used to develop gender specific prediction models for gastric cancer development, and the performance of the developed model in terms of discrimination and calibration was also validated using an independent cohort. Discrimination ability was evaluated using Harrell's C-statistics, and the calibration was evaluated using a calibration plot and slope.During a median of 11.4 years of follow-up, 19,465 (1.4% and 5,579 (0.7% newly developed gastric cancer cases were observed among 1,372,424 men and 804,077 women, respectively. The prediction models included age, BMI, family history, meal regularity, salt preference, alcohol consumption, smoking and physical activity for men, and age, BMI, family history, salt preference, alcohol consumption, and smoking for women. This prediction model showed good accuracy and predictability in both the developing and validation cohorts (C-statistics: 0.764 for men, 0.706 for women.In this study, a prediction model for gastric cancer incidence was developed that displayed a good performance.

  1. Development of a human head FE model for the impact analysis using VOXEL approach and simulation for the assessment on the focal brain injury

    International Nuclear Information System (INIS)

    Watanabe, Dai; Yuge, Kohei; Nishimoto, Tetsuya; Murakami, Shigeyuki; Takao, Hiroyuki

    2008-01-01

    In this paper, a three-dimensional digital human-head model was developed and several dynamic analyses on the head trauma were conducted. This model was built up by the VOXEL approach using 433 slice CT images (512 x 512 pixels) and made of 1.22 million parallelepiped finite elements with 10 anatomical tissue properties such as scalp, cerebrospinal fluid (CSF), skull, brain, dura mater and so on. The numerical analyses were conducted using a finite element code the authors have developed. The main features of the code are it is based on the explicit time integration method and it uses the one point integration method to evaluate the equivalent nodal forces with the hourglass control proposed by Flanagan and Belythcko and it utilizes the parallel computation with the Massage Passing Interface (MPI). In order to verify the developed model, the head impact experiment for a cadaver by Nahum et al. was simulated. The calculated results showed good agreement with experimental ones. A front and rear impact analyses were also performed investigate the relation between the impact direction and the positions of the high measurement of pressure and stresses in brain. The obtained results represent that brain injury has a closer relation with the Mises equivalent stress rather than the pressure. At this time, the large deformation of a frontal cranial base was observed in both frontal and occipital impact analyses. We expect that it induces the brain injury in a frontal lobe regardless of the impact positions. (author)

  2. Reconstruction of head-to-knee voxel model for Syrian adult male of average height and weight

    Directory of Open Access Journals (Sweden)

    Bashira Taleb

    2015-06-01

    Conclusion: Comparisons with SAFs data of Zubal model accentuated the fact that the organ masses and the specific anatomy have a significant effect on SAFs. SyrMan model can be considered as the first model built in the Middle East region, and it is an important step toward the Syrian Reference Man.

  3. Vessel-guided airway segmentation based on voxel classification

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; Sporring, Jon; Ashraf, Haseem

    2008-01-01

    This paper presents a method for improving airway tree segmentation using vessel orientation information. We use the fact that an airway branch is always accompanied by an artery, with both structures having similar orientations. This work is based on a  voxel classification airway segmentation...... method proposed previously. The probability of a voxel belonging to the airway, from the voxel classification method, is augmented with an orientation similarity measure as a criterion for region growing. The orientation similarity measure of a voxel indicates how similar is the orientation...... of the surroundings of a voxel, estimated based on a tube model, is to that of a neighboring vessel. The proposed method is tested on 20 CT images from different subjects selected randomly from a lung cancer screening study. Length of the airway branches from the results of the proposed method are significantly...

  4. ENVI Model Development for Korean Nuclear Spent Fuel Options Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sunyoung; Jeong, Yon Hong; Han, Jae-Jun; Lee, Aeri; Hwang, Yong-Soo [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2015-10-15

    The disposal facility of the spent nuclear fuel will be operated from 2051. This paper presents the ENVI code developed by GoldSim Software to simulate options for managing spent nuclear fuel (SNF) in South Korea. The ENVI is a simulator to allow decision-makers to assist to evaluate the performance for spent nuclear fuel management. The multiple options for managing the spent nuclear fuel including the storage and transportation are investigated into interim storage, permanent disposal in geological repositories and overseas and domestic reprocessing. The ENVI code uses the GoldSim software to simulate the logistics of the associated activities. The result by the ENVI model not only produces the total cost to compare among the multiple options but also predict the sizes and timings of different facilities required. In order to decide the policy for spent nuclear management this purpose of this paper is to draw the optimum management plan to solve the nuclear spent fuel issue in the economical aspects. This paper is focused on the development of the ENVI's logic and calculations to simulate four options(No Reprocessing, Overseas Reprocessing, Domestic Reprocessing, and Overseas and Domestic Reprocessing) for managing the spent nuclear fuel in South Korea. The time history of the spent nuclear fuel produced from both the existing and future NPP's can be predicted, based on the Goldsim software made available very user friendly model. The simulation result will be used to suggest the strategic plans for the spent nuclear fuel management.

  5. ENVI Model Development for Korean Nuclear Spent Fuel Options Analysis

    International Nuclear Information System (INIS)

    Chang, Sunyoung; Jeong, Yon Hong; Han, Jae-Jun; Lee, Aeri; Hwang, Yong-Soo

    2015-01-01

    The disposal facility of the spent nuclear fuel will be operated from 2051. This paper presents the ENVI code developed by GoldSim Software to simulate options for managing spent nuclear fuel (SNF) in South Korea. The ENVI is a simulator to allow decision-makers to assist to evaluate the performance for spent nuclear fuel management. The multiple options for managing the spent nuclear fuel including the storage and transportation are investigated into interim storage, permanent disposal in geological repositories and overseas and domestic reprocessing. The ENVI code uses the GoldSim software to simulate the logistics of the associated activities. The result by the ENVI model not only produces the total cost to compare among the multiple options but also predict the sizes and timings of different facilities required. In order to decide the policy for spent nuclear management this purpose of this paper is to draw the optimum management plan to solve the nuclear spent fuel issue in the economical aspects. This paper is focused on the development of the ENVI's logic and calculations to simulate four options(No Reprocessing, Overseas Reprocessing, Domestic Reprocessing, and Overseas and Domestic Reprocessing) for managing the spent nuclear fuel in South Korea. The time history of the spent nuclear fuel produced from both the existing and future NPP's can be predicted, based on the Goldsim software made available very user friendly model. The simulation result will be used to suggest the strategic plans for the spent nuclear fuel management

  6. The Effect of the Demand Control and Effort Reward Imbalance Models on the Academic Burnout of Korean Adolescents

    Science.gov (United States)

    Lee, Jayoung; Puig, Ana; Lee, Sang Min

    2012-01-01

    The purpose of this study was to examine the effects of the Demand Control Model (DCM) and the Effort Reward Imbalance Model (ERIM) on academic burnout for Korean students. Specifically, this study identified the effects of the predictor variables based on DCM and ERIM (i.e., demand, control, effort, reward, Demand Control Ratio, Effort Reward…

  7. Reconstruction of voxel phantoms for skin dosimetry

    International Nuclear Information System (INIS)

    Antunes, Paula Cristina Guimaraes

    2010-01-01

    Radiotherapy is a therapeutic modality that utilizes ionizing radiation for the destruction of neoplastic human cells. One of the requirements for this treatment methodology success lays on the appropriate use of planning systems, which performs, among other information, the patient's dose distribution estimate. Nowadays, transport codes have been providing huge subsidies to these planning systems, once it enables specific and accurate patient organ and tissue dosimetry. The model utilized by these codes to describe the human anatomy in a realistic way is known as voxel phantoms, which are represented by discrete volume elements (voxels) directly associated to tomographic data. Nowadays, voxel phantoms doable of being inserted and processed by the transport code MCNP (Monte Carlo N-Particle) presents a 3-4 mm image resolution; however, such resolution limits some thin body structure discrimination, such as skin. In this context, this work proposes a calculus routine that discriminates this region with thickness and localization in the voxel phantoms similar to the real, leading to an accurate dosimetric skin dose assessment by the MCNP code. Moreover, this methodology consists in manipulating the voxel phantoms volume elements by segmenting and subdividing it in different skin thickness. In addition to validate the skin dose calculated data, a set of experimental evaluations with thermoluminescent dosimeters were performed in an anthropomorphic phantom. Due to significant differences observed on the dose distribution of several skin representations, it was found that is important to discriminate the skin thickness similar to the real. The presented methodology is useful to obtain an accurate skin dosimetric evaluation for several radiotherapy procedures, with particular interest on the electron beam radiotherapy, in which highlights the whole body irradiation therapy (TSET), a procedure under implementation at the Hospital das Clinicas da Faculdade de Medicina da

  8. The ratio of ICRP103 to ICRP60 calculated effective doses from CT: Monte Carlo calculations with the ADELAIDE voxel paediatric model and comparisons with published values

    International Nuclear Information System (INIS)

    Caon, Martin

    2013-01-01

    The ADELAIDE voxel model of paediatric anatomy was used with the EGSnrc Monte Carlo code to compare effective dose from computed tomography (CT) calculated with both the ICRP103 and ICRP60 definitions which are different in their tissue weighting factors and in the included tissues. The new tissue weighting factors resulted in a lower effective dose for pelvis CT (than if calculated using ICRP60 tissue weighting factors), by 6.5 % but higher effective doses for all other examinations. ICRP103 calculated effective dose for CT abdomen + pelvis was higher by 4.6 %, for CT abdomen (by 9.5 %), for CT chest + abdomen + pelvis (by 6 %), for CT chest + abdomen (by 9.6 %), for CT chest (by 10.1 %) and for cardiac CT (by 11.5 %). These values, along with published values of effective dose from CT that were calculated for both sets of tissue weighting factors were used to determine single values for the ratio ICRP103:ICRP60 calculated effective doses from CT, for seven CT examinations. The following values for ICRP103:ICRP60 are suggested for use to convert ICRP60 calculated effective dose to ICRP103 calculated effective dose for the following CT examinations: Pelvis CT, 0.75; for abdomen CT, abdomen + pelvis CT, chest + abdomen + pelvis CT, 1.00; for chest + abdomen CT, and for chest CT. 1.15; for cardiac CT 1.25.

  9. Construction tool and suitability of voxel phantom for skin dosimetry

    International Nuclear Information System (INIS)

    Antunes, Paula C.G.; Siqueira, Paulo T.D.; Fonseca, Gabriel P.; Yoriyaz, Helio

    2011-01-01

    This paper describes a new software tool called 'SkinVop' which was developed to enable accurate voxel phantom skin dosimetry. A voxel phantom is a model used to describe human anatomy in a realistic way in radiation transport codes. This model is a three-dimensional representation of the human body in the form of an array of identification numbers that are arranged in a 3D matrix. Each entry in this array represents a voxel (volume element) directly associated to the units of picture resolution (pixel) of medical images. Currently, these voxel phantoms, in association with the transport code MCNP (Monte Carlo N-Particle), have provided subsidies to the planning systems used on the hospital routine, once they afford accurate and personalized estimative of dose distribution. However, these assessments are limited to geometric representations of organs and tissues in the voxel phantom, which do not discriminates some thin body structure, such as the skin. In this context, to enable accurate dosimetric skin dose assessment by the MCNP code, it was developed this new software tool that discriminates this region with thickness and localization in the voxel phantoms similar to the real. This methodology consists in manipulating the skin volume elements by segmenting and subdividing them in different thicknesses. A graphical user interface was designed to fulfill display the modified voxel model. This methodology is extremely useful once the skin dose is inaccurately assessed of current hospital system planning, justified justly by its small thickness. (author)

  10. Construction tool and suitability of voxel phantom for skin dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Paula C.G.; Siqueira, Paulo T.D.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: ptsiquei@ipen.b, E-mail: hyoriyaz@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This paper describes a new software tool called 'SkinVop' which was developed to enable accurate voxel phantom skin dosimetry. A voxel phantom is a model used to describe human anatomy in a realistic way in radiation transport codes. This model is a three-dimensional representation of the human body in the form of an array of identification numbers that are arranged in a 3D matrix. Each entry in this array represents a voxel (volume element) directly associated to the units of picture resolution (pixel) of medical images. Currently, these voxel phantoms, in association with the transport code MCNP (Monte Carlo N-Particle), have provided subsidies to the planning systems used on the hospital routine, once they afford accurate and personalized estimative of dose distribution. However, these assessments are limited to geometric representations of organs and tissues in the voxel phantom, which do not discriminates some thin body structure, such as the skin. In this context, to enable accurate dosimetric skin dose assessment by the MCNP code, it was developed this new software tool that discriminates this region with thickness and localization in the voxel phantoms similar to the real. This methodology consists in manipulating the skin volume elements by segmenting and subdividing them in different thicknesses. A graphical user interface was designed to fulfill display the modified voxel model. This methodology is extremely useful once the skin dose is inaccurately assessed of current hospital system planning, justified justly by its small thickness. (author)

  11. Assessments of Future Maize Yield Potential Changes in the Korean Peninsula Using Multiple Crop Models

    Science.gov (United States)

    Kim, S. H.; Lim, C. H.; Kim, J.; Lee, W. K.; Kafatos, M.

    2016-12-01

    The Korean Peninsula has unique agricultural environment due to the differences of political and socio-economical system between Republic of Korea (SK, hereafter) and Democratic Peoples' Republic of Korea (NK, hereafter). NK has been suffering lack of food supplies caused by natural disasters, land degradation and political failure. The neighboring developed country SK has better agricultural system but very low food self-sufficiency rate. Maize is an important crop in both countries since it is staple food for NK and SK is No. 2 maize importing country in the world after Japan. Therefore, evaluating maize yield potential (Yp) in the two distinct regions is essential to assess food security under climate change and variability. In this study, we utilized multiple process-based crop models, having ability of regional scale assessment, to evaluate maize Yp and assess the model uncertainties -EPIC, GEPIC, DSSAT, and APSIM model that has capability of regional scale expansion (apsimRegions). First we evaluated each crop model for 3 years from 2012 to 2014 using reanalysis data (RDAPS; Regional Data Assimilation and Prediction System produced by Korea Meteorological Agency) and observed yield data. Each model performances were compared over the different regions in the Korean Peninsula having different local climate characteristics. To quantify of the major influence of at each climate variables, we also conducted sensitivity test using 20 years of climatology in historical period from 1981 to 2000. Lastly, the multi-crop model ensemble analysis was performed for future period from 2031 to 2050. The required weather variables projected for mid-century were employed from COordinated Regional climate Downscaling EXperiment (CORDEX) East Asia. The high-resolution climate data were obtained from multiple regional climate models (RCM) driven by multiple climate scenarios projected from multiple global climate models (GCMs) in conjunction with multiple greenhouse gas

  12. MO-F-CAMPUS-J-01: Effect of Iodine Contrast Agent Concentration On Cerebrovascular Dose for Synchrotron Radiation Microangiography Based On a Simple Mouse Head Model and a Voxel Mouse Head Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lin, H; Jing, J; Xie, C [Hefei University of Technology, Hefei (China); Lu, Y [Shanghai Jiao Tong University, Shanghai (China)

    2015-06-15

    Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results: The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.

  13. Detection by voxel-wise statistical analysis of significant changes in regional cerebral glucose uptake in an APP/PS1 transgenic mouse model of Alzheimer's disease.

    Science.gov (United States)

    Dubois, Albertine; Hérard, Anne-Sophie; Delatour, Benoît; Hantraye, Philippe; Bonvento, Gilles; Dhenain, Marc; Delzescaux, Thierry

    2010-06-01

    Biomarkers and technologies similar to those used in humans are essential for the follow-up of Alzheimer's disease (AD) animal models, particularly for the clarification of mechanisms and the screening and validation of new candidate treatments. In humans, changes in brain metabolism can be detected by 1-deoxy-2-[(18)F] fluoro-D-glucose PET (FDG-PET) and assessed in a user-independent manner with dedicated software, such as Statistical Parametric Mapping (SPM). FDG-PET can be carried out in small animals, but its resolution is low as compared to the size of rodent brain structures. In mouse models of AD, changes in cerebral glucose utilization are usually detected by [(14)C]-2-deoxyglucose (2DG) autoradiography, but this requires prior manual outlining of regions of interest (ROI) on selected sections. Here, we evaluate the feasibility of applying the SPM method to 3D autoradiographic data sets mapping brain metabolic activity in a transgenic mouse model of AD. We report the preliminary results obtained with 4 APP/PS1 (64+/-1 weeks) and 3 PS1 (65+/-2 weeks) mice. We also describe new procedures for the acquisition and use of "blockface" photographs and provide the first demonstration of their value for the 3D reconstruction and spatial normalization of post mortem mouse brain volumes. Despite this limited sample size, our results appear to be meaningful, consistent, and more comprehensive than findings from previously published studies based on conventional ROI-based methods. The establishment of statistical significance at the voxel level, rather than with a user-defined ROI, makes it possible to detect more reliably subtle differences in geometrically complex regions, such as the hippocampus. Our approach is generic and could be easily applied to other biomarkers and extended to other species and applications. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Modeling of hand function by mapping the motion of individual muscle voxels with MR imaging velocity tagging

    International Nuclear Information System (INIS)

    Drace, J.; Pele, N.; Herfkens, R.J.

    1990-01-01

    This paper reports on a method to correlate the three-dimensional (3D) motion of the fingers with the complex motion of the intrinsic, flexor, and extensor muscles. A better understanding of hand function is important to the medical, surgical, and rehabilitation treatment of patients with arthritic, neurogenic, and mechanical hand dysfunctions. Static, high-resolution MR volumetric imaging defines the 3D shape of each individual bone in the hands of three subjects and three patients. Single-section velocity-tagging sequences (VIGOR) are performed through the hand and forearm, while the actual 3D motion of the hand is computed from the MR model and readings of fiber-optic goniometers attached to each finger. The accuracy of the velocity tagging is also tested with a motion phantom

  15. Construction of a computational exposure model for dosimetric calculations using the EGS4 Monte Carlo code and voxel phantoms

    International Nuclear Information System (INIS)

    Vieira, Jose Wilson

    2004-07-01

    The MAX phantom has been developed from existing segmented images of a male adult body, in order to achieve a representation as close as possible to the anatomical properties of the reference adult male specified by the ICRP. In computational dosimetry, MAX can simulate the geometry of a human body under exposure to ionizing radiations, internal or external, with the objective of calculating the equivalent dose in organs and tissues for occupational, medical or environmental purposes of the radiation protection. This study presents a methodology used to build a new computational exposure model MAX/EGS4: the geometric construction of the phantom; the development of the algorithm of one-directional, divergent, and isotropic radioactive sources; new methods for calculating the equivalent dose in the red bone marrow and in the skin, and the coupling of the MAX phantom with the EGS4 Monte Carlo code. Finally, some results of radiation protection, in the form of conversion coefficients between equivalent dose (or effective dose) and free air-kerma for external photon irradiation are presented and discussed. Comparing the results presented with similar data from other human phantoms it is possible to conclude that the coupling MAX/EGS4 is satisfactory for the calculation of the equivalent dose in radiation protection. (author)

  16. Interactive voxel graphics in virtual reality

    Science.gov (United States)

    Brody, Bill; Chappell, Glenn G.; Hartman, Chris

    2002-06-01

    Interactive voxel graphics in virtual reality poses significant research challenges in terms of interface, file I/O, and real-time algorithms. Voxel graphics is not so new, as it is the focus of a good deal of scientific visualization. Interactive voxel creation and manipulation is a more innovative concept. Scientists are understandably reluctant to manipulate data. They collect or model data. A scientific analogy to interactive graphics is the generation of initial conditions for some model. It is used as a method to test those models. We, however, are in the business of creating new data in the form of graphical imagery. In our endeavor, science is a tool and not an end. Nevertheless, there is a whole class of interactions and associated data generation scenarios that are natural to our way of working and that are also appropriate to scientific inquiry. Annotation by sketching or painting to point to and distinguish interesting and important information is very significant for science as well as art. Annotation in 3D is difficult without a good 3D interface. Interactive graphics in virtual reality is an appropriate approach to this problem.

  17. Impact of Social Integration and Living Arrangements on Korean Older Adults' Depression: A Moderation Model.

    Science.gov (United States)

    Lee, Youjung; Jang, Kyeonghee; Lockhart, Naorah C

    2018-04-01

    Depression among older adults is a challenging public health concern in Korea. Using panel data from the Korea Institute for Health and Social Affairs on Korean older adults and their family caregivers, this study explores significant predictors of depression among Korean older adults as well as the moderating effect of living arrangements on the association between social integration and depression. A multivariate logistic regression analysis showed that preexisting depression was the most significant predictor of Korean older adults' current depression, followed by health status and family support. In addition, social integration significantly decreased Korean older adults' depression. Importantly, a significant moderation effect of living arrangements between Korean older adults' social integration and depression was observed. This study implies the development of individually tailored and culturally responsive programs to engage marginalized Korean older adults living alone, helping foster their well-being and optimal aging.

  18. Gender-Specific Models of Work-Bound Korean Adolescents' Social Supports and Career Adaptability on Subsequent Job Satisfaction

    Science.gov (United States)

    Han, Hyojung; Rojewski, Jay W.

    2015-01-01

    A Korean national database, the High School Graduates Occupational Mobility Survey, was used to examine the influence of perceived social supports (family and school) and career adaptability on the subsequent job satisfaction of work-bound adolescents 4 months after their transition from high school to work. Structural equation modeling analysis…

  19. Surface models of the male urogenital organs built from the Visible Korean using popular software

    Science.gov (United States)

    Shin, Dong Sun; Park, Jin Seo; Shin, Byeong-Seok

    2011-01-01

    Unlike volume models, surface models, which are empty three-dimensional images, have a small file size, so they can be displayed, rotated, and modified in real time. Thus, surface models of male urogenital organs can be effectively applied to an interactive computer simulation and contribute to the clinical practice of urologists. To create high-quality surface models, the urogenital organs and other neighboring structures were outlined in 464 sectioned images of the Visible Korean male using Adobe Photoshop; the outlines were interpolated on Discreet Combustion; then an almost automatic volume reconstruction followed by surface reconstruction was performed on 3D-DOCTOR. The surface models were refined and assembled in their proper positions on Maya, and a surface model was coated with actual surface texture acquired from the volume model of the structure on specially programmed software. In total, 95 surface models were prepared, particularly complete models of the urinary and genital tracts. These surface models will be distributed to encourage other investigators to develop various kinds of medical training simulations. Increasingly automated surface reconstruction technology using commercial software will enable other researchers to produce their own surface models more effectively. PMID:21829759

  20. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches

    NARCIS (Netherlands)

    Nada, R.M.; Maal, T.J.J.; Breuning, K.H.; Berge, S.J.; Mostafa, Y.A.; Kuijpers-Jagtman, A.M.

    2011-01-01

    Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans.

  1. A voxel visualization and analysis system based on AutoCAD

    Science.gov (United States)

    Marschallinger, Robert

    1996-05-01

    A collection of AutoLISP programs is presented which enable the visualization and analysis of voxel models by AutoCAD rel. 12/rel. 13. The programs serve as an interactive, graphical front end for manipulating the results of three-dimensional modeling software producing block estimation data. ASCII data files describing geometry and attributes per estimation block are imported and stored as a voxel array. Each voxel may contain multiple attributes, therefore different parameters may be incorporated in one voxel array. Voxel classification is implemented on a layer basis providing flexible treatment of voxel classes such as recoloring, peeling, or volumetry. A versatile clipping tool enables slicing voxel arrays according to combinations of three perpendicular clipping planes. The programs feature an up-to-date, graphical user interface for user-friendly operation by non AutoCAD specialists.

  2. Modification of SWAT model for simulation of organic matter in Korean watersheds.

    Science.gov (United States)

    Jang, Jae-Ho; Jung, Kwang-Wook; Gyeong Yoon, Chun

    2012-01-01

    The focus of water quality modeling of Korean streams needs to be shifted from dissolved oxygen to algae or organic matter. In particular, the structure of water quality models should be modified to simulate the biochemical oxygen demand (BOD), which is a key factor in calculating total maximum daily loads (TMDLs) in Korea, using 5-day BOD determined in the laboratory (Bottle BOD(5)). Considering the limitations in simulating organic matter under domestic conditions, we attempted to model total organic carbon (TOC) as well as BOD by using a watershed model. For this purpose, the Soil and Water Assessment Tool (SWAT) model was modified and extended to achieve better correspondence between the measured and simulated BOD and TOC concentrations. For simulated BOD in the period 2004-2008, the Nash-Sutcliffe model efficiency coefficient increased from a value of -2.54 to 0.61. Another indicator of organic matter, namely, the simulated TOC concentration showed that the modified SWAT adequately reflected the observed values. The improved model can be used to predict organic matter and hence, may be a potential decision-making tool for TMDLs. However, it needs further testing for longer simulation periods and other catchments.

  3. Korean Solar Salt Ameliorates Colon Carcinogenesis in an AOM/DSS-Induced C57BL/6 Mouse Model.

    Science.gov (United States)

    Ju, Jaehyun; Kim, Yeung-Ju; Park, Eui Seong; Park, Kun-Young

    2017-06-01

    The effects of Korean solar salt on an azoxymethane (AOM)/dextran sodium sulfate (DSS)-induced colon cancer C57BL/6 mouse model were studied. Korean solar salt samples (SS-S, solar salt from S salt field; SS-Yb, solar salt from Yb salt field), nine-time-baked bamboo salt (BS-9x, made from SS-Yb), purified salt (PS), and SS-G (solar salt from Guérande, France) were orally administered at a concentration of 1% during AOM/DSS colon cancer induction, and compared for their protective effects during colon carcinogenesis in C57BL/6 mice. SS-S and SS-Yb suppressed colon length shortening and tumor counts in mouse colons. Histological evaluation by hematoxylin and eosin staining also revealed suppression of tumorigenesis by SS-S. Conversely, PS and SS-G did not show a similar suppressive efficacy as Korean solar salt. SS-S and SS-Yb promoted colon mRNA expression of an apoptosis-related factor and cell-cycle-related gene and suppressed pro-inflammatory factor. SS-Yb baked into BS-9x further promoted these anti-carcinogenic efficacies. Taken together, the results indicate that Korean solar salt, especially SS-S and SS-Yb, exhibited anti-cancer activity by modulating apoptosis- and inflammation-related gene expression during colon carcinogenesis in mice, and bamboo salt baked from SS-Yb showed enhanced anti-cancer functionality.

  4. Comparison of the Usefulness of the Updated Homeostasis Model Assessment (HOMA2) with the Original HOMA1 in the Prediction of Type 2 Diabetes Mellitus in Koreans

    OpenAIRE

    Song, Young Seok; Hwang, You-Cheol; Ahn, Hong-Yup; Park, Cheol-Young

    2016-01-01

    Background The original homeostasis model assessment (HOMA1) and the updated HOMA model (HOMA2) have been used to evaluate insulin resistance (IR) and ?-cell function, but little is known about the usefulness of HOMA2 for the prediction of diabetes in Koreans. The aim of this study was to demonstrate the usefulness of HOMA2 as a predictor of type 2 diabetes mellitus in Koreans without diabetes. Methods The study population consisted of 104,694 Koreans enrolled at a health checkup program and ...

  5. Comparison of the Usefulness of the Updated Homeostasis Model Assessment (HOMA2) with the Original HOMA1 in the Prediction of Type 2 Diabetes Mellitus in Koreans

    OpenAIRE

    Young Seok Song; You-Cheol Hwang; Hong-Yup Ahn; Cheol-Young Park

    2016-01-01

    BackgroundThe original homeostasis model assessment (HOMA1) and the updated HOMA model (HOMA2) have been used to evaluate insulin resistance (IR) and β-cell function, but little is known about the usefulness of HOMA2 for the prediction of diabetes in Koreans. The aim of this study was to demonstrate the usefulness of HOMA2 as a predictor of type 2 diabetes mellitus in Koreans without diabetes.MethodsThe study population consisted of 104,694 Koreans enrolled at a health checkup program and fol...

  6. A goodness of fit and validity study of the Korean radiological technologists' core job competency model

    International Nuclear Information System (INIS)

    Lim, Chang Seon; Cho, A Ra; Hur, Yera; Choi, Seong Youl

    2017-01-01

    Radiological Technologists deals with the life of a person which means professional competency is essential for the job. Nevertheless, there have been no studies in Korea that identified the job competence of radiologists. In order to define the core job competencies of Korean radiologists and to present the factor models, 147 questionnaires on job competency of radiology were analyzed using 'PASW Statistics Version 18.0' and 'AMOS Version 18.0'. The valid model consisted of five core job competencies ('Patient management', 'Health and safety', 'Operation of equipment', 'Procedures and management') and 17 sub – competencies. As a result of the factor analysis, the RMSEA value was 0.1 and the CFI, and TLI values were close to 0.9 in the measurement model of the five core job competencies. The validity analysis showed that the mean variance extraction was 0.5 or more and the conceptual reliability value was 0.7 or more , And there was a high correlation between subordinate competencies included in each subordinate competencies. The results of this study are expected to provide specific information necessary for the training and management of human resources centered on competence by clearly showing the job competence required for radiologists in Korea's health environment

  7. DTI analysis methods : Voxel-based analysis

    NARCIS (Netherlands)

    Van Hecke, Wim; Leemans, Alexander; Emsell, Louise

    2016-01-01

    Voxel-based analysis (VBA) of diffusion tensor imaging (DTI) data permits the investigation of voxel-wise differences or changes in DTI metrics in every voxel of a brain dataset. It is applied primarily in the exploratory analysis of hypothesized group-level alterations in DTI parameters, as it does

  8. Construction of a computational exposure model for dosimetric calculations using the EGS4 Monte Carlo code and voxel phantoms; Construcao de um modelo computacional de exposicao para calculos dosimetricos utilizando o codigo Monte Carlo EGS4 e fantomas de voxels

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Jose Wilson

    2004-07-15

    The MAX phantom has been developed from existing segmented images of a male adult body, in order to achieve a representation as close as possible to the anatomical properties of the reference adult male specified by the ICRP. In computational dosimetry, MAX can simulate the geometry of a human body under exposure to ionizing radiations, internal or external, with the objective of calculating the equivalent dose in organs and tissues for occupational, medical or environmental purposes of the radiation protection. This study presents a methodology used to build a new computational exposure model MAX/EGS4: the geometric construction of the phantom; the development of the algorithm of one-directional, divergent, and isotropic radioactive sources; new methods for calculating the equivalent dose in the red bone marrow and in the skin, and the coupling of the MAX phantom with the EGS4 Monte Carlo code. Finally, some results of radiation protection, in the form of conversion coefficients between equivalent dose (or effective dose) and free air-kerma for external photon irradiation are presented and discussed. Comparing the results presented with similar data from other human phantoms it is possible to conclude that the coupling MAX/EGS4 is satisfactory for the calculation of the equivalent dose in radiation protection. (author)

  9. Development of a prototype Typhoon Risk Model over the Korean Peninsula

    Science.gov (United States)

    Kim, K. Y.; Cocke, S.; Shin, D. W.; CHOI, M.; Kwon, J.

    2016-12-01

    Risk can be defined as probability of a given hazard of a given level causing a particular level of loss of damage (Alexander, 2000). Risk management is important for mitigation and developing plans for emergencies. More effective risk management strategies can help reduce potential losses from natural disasters like typhoon, floods, earthquakes, and so on. We are developing a prototype typhoon risk model to assess the current and potentially future hazard due to typhoons in the Western Pacific. To develop the typhoon risk model, a variety of sources of data over Korea are used such as population, damage to buildings, agriculture, ships, etc. The model is based on proven concepts used in catastrophe models that have been used in the U.S. and other regions of the world. Recently, the sea surface temperatures where typhoons have occurred have tended to increase. According to recent studies of global warming, the intensity of typhoons could increase, and the frequency of typhoons may decrease in the future climate. The prototype risk model can help us determine the change in risk as a consequence of the change in typhoon activity. We focus on Korea and other regions of interest to Korean insurers, re-insurers, and related industries. The model can potentially be coupled to various damage models or emergency management systems for planning and mitigation. In addition, the assessment would be useful for emergency planners, coastal community planners, and private and governmental insurance programs. This work was funded by the Korea Meteorological Administration Research and Development Program under Grant KMIPA2016-8030.

  10. Voxel inversion of airborne EM data

    DEFF Research Database (Denmark)

    Fiandaca, Gianluca G.; Auken, Esben; Christiansen, Anders Vest C A.V.C.

    2013-01-01

    We present a geophysical inversion algorithm working directly in a voxel grid disconnected from the actual measuring points, which allows for straightforward integration of different data types in joint inversion, for informing geological/hydrogeological models directly and for easier incorporation...... of prior information. Inversion of geophysical data usually refers to a model space being linked to the actual observation points. For airborne surveys the spatial discretization of the model space reflects the flight lines. Often airborne surveys are carried out in areas where other ground......-based geophysical data are available. The model space of geophysical inversions is usually referred to the positions of the measurements, and ground-based model positions do not generally coincide with the airborne model positions. Consequently, a model space based on the measuring points is not well suited...

  11. Analyzing Korean consumers’ latent preferences for electricity generation sources with a hierarchical Bayesian logit model in a discrete choice experiment

    International Nuclear Information System (INIS)

    Byun, Hyunsuk; Lee, Chul-Yong

    2017-01-01

    Generally, consumers use electricity without considering the source the electricity was generated from. Since different energy sources exert varying effects on society, it is necessary to analyze consumers’ latent preference for electricity generation sources. The present study estimates Korean consumers’ marginal utility and an appropriate generation mix is derived using the hierarchical Bayesian logit model in a discrete choice experiment. The results show that consumers consider the danger posed by the source of electricity as the most important factor among the effects of electricity generation sources. Additionally, Korean consumers wish to reduce the contribution of nuclear power from the existing 32–11%, and increase that of renewable energy from the existing 4–32%. - Highlights: • We derive an electricity mix reflecting Korean consumers’ latent preferences. • We use the discrete choice experiment and hierarchical Bayesian logit model. • The danger posed by the generation source is the most important attribute. • The consumers wish to increase the renewable energy proportion from 4.3% to 32.8%. • Korea's cost-oriented energy supply policy and consumers’ preference differ markedly.

  12. A Test of an Integrative Model Using Social Factors and Personality Traits: Prediction on the Delinquency of South Korean Youth.

    Science.gov (United States)

    Yun, Minwoo; Kim, Eunyoung; Park, Woong-Sub

    2017-08-01

    To more fully comprehend juvenile delinquency, it is necessary to take an integrative approach, with consideration of both personality traits of social risk factors. Many scholars argue the necessity and strength of integrative approach on the ground that juvenile delinquency is an outcome of interplay of individual and social factors. The present study examines the general applicability of an integrative model of personal traits and social risk factors to youth delinquency in the South Korean context. The empirical results show that the delinquency predictors in the current South Korean sample are closely aligned to Loeber and Farrington's theoretical propositions and that found in Western nations. Perhaps this is because South Korea has undergone rapid Westernization for the last decades. Because the correlates in this sample and Western theoretical propositions and studies overlap, an integrative model of personality trait and social risk factors is indeed generally applicable to South Korea. This finding also depicts the extent of Westernization in the South Korean society at least among adolescents. Limitations of the present study and directions for the future study are discussed.

  13. Voxel-based model construction from colored tomographic images; Construcao de simuladores baseados em elementos de volume a partir de imagens tomograficas coloridas

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Eduardo Cesar de Miranda

    2002-07-01

    This work presents a new approach in the construction of voxel-based phantoms that was implemented to simplify the segmentation process of organs and tissues reducing the time used in this procedure. The segmentation process is performed by painting tomographic images and attributing a different color for each organ or tissue. A voxel-based head and neck phantom was built using this new approach. The way as the data are stored allows an increasing in the performance of the radiation transport code. The program that calculates the radiation transport also works with image files. This capability allows image reconstruction showing isodose areas, under several points of view, increasing the information to the user. Virtual X-ray photographs can also be obtained allowing that studies could be accomplished looking for the radiographic techniques optimization assessing, at the same time, the doses in organs and tissues. The accuracy of the program here presented, called MCvoxEL, that implements this new approach, was tested by comparison to results from two modern and well-supported Monte Carlo codes. Dose conversion factors for parallel X-ray exposure were also calculated. (author)

  14. The risk factors of laryngeal pathology in Korean adults using a decision tree model.

    Science.gov (United States)

    Byeon, Haewon

    2015-01-01

    The purpose of this study was to identify risk factors affecting laryngeal pathology in the Korean population and to evaluate the derived prediction model. Cross-sectional study. Data were drawn from the 2008 Korea National Health and Nutritional Examination Survey. The subjects were 3135 persons (1508 male and 2114 female) aged 19 years and older living in the community. The independent variables were age, sex, occupation, smoking, alcohol drinking, and self-reported voice problems. A decision tree analysis was done to identify risk factors for predicting a model of laryngeal pathology. The significant risk factors of laryngeal pathology were age, gender, occupation, smoking, and self-reported voice problem in decision tree model. Four significant paths were identified in the decision tree model for the prediction of laryngeal pathology. Those identified as high risk groups for laryngeal pathology included those who self-reported a voice problem, those who were males in their 50s who did not recognize a voice problem, those who were not economically active males in their 40s, and male workers aged 19 and over and under 50 or 60 and over who currently smoked. The results of this study suggest that individual risk factors, such as age, sex, occupation, health behavior, and self-reported voice problem, affect the onset of laryngeal pathology in a complex manner. Based on the results of this study, early management of the high-risk groups is needed for the prevention of laryngeal pathology. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  15. Comparison of rate theory based modeling calculations with the surveillance test results of Korean light water reactors

    International Nuclear Information System (INIS)

    Lee, Gyeong Geun; Lee, Yong Bok; Kim, Min Chul; Kwon, Junh Yun

    2012-01-01

    Neutron irradiation to reactor pressure vessel (RPV) steels causes a decrease in fracture toughness and an increase in yield strength while in service. It is generally accepted that the growth of point defect cluster (PDC) and copper rich precipitate (CRP) affects radiation hardening of RPV steels. A number of models have been proposed to account for the embrittlement of RPV steels. The rate theory based modeling mathematically described the evolution of radiation induced microstructures of ferritic steels under neutron irradiation. In this work, we compared the rate theory based modeling calculation with the surveillance test results of Korean Light Water Reactors (LWRs)

  16. Application of the transtheoretical model: exercise behavior in Korean adults with metabolic syndrome.

    Science.gov (United States)

    Kim, Chun-Ja; Kim, Bom-Taeck; Chae, Sun-Mi

    2010-01-01

    Although regular exercise has been recommended to reduce the risk of cardiovascular disease (CVD) among people with metabolic syndrome, little information is available about psychobehavioral strategies in this population. The purpose of this study was to identify the stages, processes of change, decisional balance, and self-efficacy of exercise behavior and to determine the significant predictors explaining regular exercise behavior in adults with metabolic syndrome. This descriptive, cross-sectional survey design enrolled a convenience sample of 210 people with metabolic syndrome at a university hospital in South Korea. Descriptive statistics were used to analyze demographic characteristics, metabolic syndrome risk factors, and transtheoretical model-related variables. A multivariate logistic regression analysis was used to determine the most important predictors of regular exercise stages. Action and maintenance stages comprised 51.9% of regular exercise stages, whereas 48.1% of non-regular exercise stages were precontemplation, contemplation, and preparation stages. Adults with regular exercise stages displayed increased high-density lipoprotein cholesterol level, were more likely to use consciousness raising, self-reevaluation, and self-liberation strategies, and were less likely to evaluate the merits/disadvantages of exercise, compared with those in non-regular exercise stages. In this study of regular exercise behavior and transtheoretical model-related variables, consciousness raising, self-reevaluation, and self-liberation were associated with a positive effect on regular exercise behavior in adults with metabolic syndrome. Our findings could be used to develop strategies and interventions to maintain regular exercise behavior directed at Korean adults with metabolic syndrome to reduce CVD risk. Further prospective intervention studies are needed to investigate the effect of regular exercise program on the prevention and/or reduction of CVD risk among this

  17. Supplementation of Korean Red Ginseng improves behavior deviations in animal models of autism

    Directory of Open Access Journals (Sweden)

    Edson Luck T. Gonzales

    2016-02-01

    Full Text Available Background: Autism spectrum disorder (ASD is heterogeneous neurodevelopmental disorders that primarily display social and communication impairments and restricted/repetitive behaviors. ASD prevalence has increased in recent years, yet very limited therapeutic targets and treatments are available to counteract the incapacitating disorder. Korean Red Ginseng (KRG is a popular herbal plant in South Korea known for its wide range of therapeutic effects and nutritional benefits and has recently been gaining great scientific attention, particularly for its positive effects in the central nervous system. Objectives: Thus, in this study, we investigated the therapeutic potential of KRG in alleviating the neurobehavioral deficits found in the valproic acid (VPA-exposed mice models of ASD. Design: Starting at 21 days old (P21, VPA-exposed mice were given daily oral administrations of KRG solution (100 or 200 mg/kg until the termination of all experiments. From P28, mice behaviors were assessed in terms of social interaction capacity (P28–29, locomotor activity (P30, repetitive behaviors (P32, short-term spatial working memory (P34, motor coordination (P36, and seizure susceptibility (P38. Results: VPA-exposed mice showed sociability and social novelty preference deficits, hyperactivity, increased repetitive behavior, impaired spatial working memory, slightly affected motor coordination, and high seizure susceptibility. Remarkably, long-term KRG treatment in both dosages normalized all the ASD-related behaviors in VPA-exposed mice, except motor coordination ability. Conclusion: As a food and herbal supplement with various known benefits, KRG demonstrated its therapeutic potential in rescuing abnormal behaviors related to autism caused by prenatal environmental exposure to VPA.

  18. Three Local "Arirang" Songs as Models for Teaching Korean Music in the Classroom

    Science.gov (United States)

    Park, Young Joo

    2013-01-01

    This article provides guidance for music teachers who want to introduce Korean folk music to their students. It introduces "Arirang"--both a specific folk song and a category--and describes three different versions: the "Miryang Arirang," the "Jindo Arirang," and the "Gyeonggi Arirang." The…

  19. Beyond the Model Minority Myth: Interrogating the Lived Experiences of Korean American Gay Men in College

    Science.gov (United States)

    Strayhorn, Terrell L.

    2014-01-01

    Scholars have examined the experiences of GLBT students in college and found that gay students often report encountering unwelcoming campus environments, physical or verbal assault, and homophobia. Rarely, however, have the experiences of Asian Pacific Islander (API) or more specifically South Korean gay men been accounted for in the literature. A…

  20. Alderson-Rando phantom 'voxelization' for use in numerical dosimetry

    International Nuclear Information System (INIS)

    Santos, A.M.; Vieira, J.W.

    2008-01-01

    This paper presents the methodology used for creating a voxel phantom from the tomographic physical Alderson-Rando phantom images (HR) and to develop a computer model formed by exposure of the resulting phantom 'voxelization' of AR coupled to the Monte Carlo code EGS4 plus algorithms to simulate radioactive sources in internal dosimetry

  1. Proteomic Analysis of the Effect of Korean Red Ginseng in the Striatum of a Parkinson?s Disease Mouse Model

    OpenAIRE

    Kim, Dongsoo; Jeon, Hyongjun; Ryu, Sun; Koo, Sungtae; Ha, Ki-Tae; Kim, Seungtae

    2016-01-01

    Recent studies have shown that Korean Red Ginseng (KRG) suppresses dopaminergic neuronal death in the brain of a Parkinson's disease (PD) mouse model, but the mechanism is still elusive. Using a 2-dimensional electrophoresis technique, we investigated whether KRG can restore the changes in protein expressions in the striatum (ST) of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-injected mice. Male C57BL/6 mice (9 weeks old) were injected with 20 mg/kg MPTP intraperitoneally four times a...

  2. The Improved Relevance Voxel Machine

    DEFF Research Database (Denmark)

    Ganz, Melanie; Sabuncu, Mert; Van Leemput, Koen

    The concept of sparse Bayesian learning has received much attention in the machine learning literature as a means of achieving parsimonious representations of features used in regression and classification. It is an important family of algorithms for sparse signal recovery and compressed sensing....... Hence in its current form it is reminiscent of a greedy forward feature selection algorithm. In this report, we aim to solve the problems of the original RVoxM algorithm in the spirit of [7] (FastRVM).We call the new algorithm Improved Relevance Voxel Machine (IRVoxM). Our contributions...... and enables basis selection from overcomplete dictionaries. One of the trailblazers of Bayesian learning is MacKay who already worked on the topic in his PhD thesis in 1992 [1]. Later on Tipping and Bishop developed the concept of sparse Bayesian learning [2, 3] and Tipping published the Relevance Vector...

  3. REKONSTRUKSI OBYEK TIGA DIMENSI DARI GAMBAR DUA DIMENSI MENGGUNAKAN METODE GENERALIZED VOXEL COLORING–LAYERED DEPTH IMAGE

    Directory of Open Access Journals (Sweden)

    Rudy Adipranata

    2008-01-01

    Full Text Available The objective of this research is to develop software which capable to reconstruct 3D object from 2D images as references using Generalized Voxel Coloring - Layered Depth Image method (GVC-LDI. This method reconstruct 3D object using LDI link list as help to find voxels which correspond to the objects based on color. To find the voxels, we calculate the color standard deviation of the pixels which is projected from the object. If the standard deviation is smaller than the threshold, the voxel evaluated as a part of the object. The process repeated for each voxel until it gets all of the voxels which shape the object. The voxels can be drawn to screen to get the photorealistic 3D object that represent the 2D images. In this research, we also compare the result of GVC-LDI and Generalized Voxel Coloring – Image Buffer (GVC-IB which is one of the GVC variant also. Future development of the software is automatic 3D modeling application and real time 3D animation application. Abstract in Bahasa Indonesia : Pada penelitian ini dikembangkan sebuah perangkat lunak untuk merekonstruksi obyek tiga dimensi dari kumpulan gambar dua dimensi dengan menggunakan metode generalized voxel coloring– layered depth image (GVC-LDI. Metode GVC-LDI ini melakukan rekonstruksi dengan bantuan link list LDI guna mencari voxel-voxel yang merupakan bagian dari obyek tiga dimensi berdasarkan warna. Guna penentuan voxel tersebut dilakukan perhitungan dari pixel-pixel yang merupakan proyeksi dari sebuah voxel. Perhitungan dilakukan dengan menggunakan standar deviasi warna untuk menentukan apakah pixel-pixel yang bersesuaian mewakili lokasi obyek yang sama. Apabila standar deviasi warna lebih kecil dari threshold maka dapat dikatakan bahwa voxel tersebut termasuk bagian obyek. Proses ini dilakukan secara berulang untuk semua voxel hingga didapatkan voxel-voxel yang merupakan bagian dari obyek. Voxel tersebut kemudian digambar pada layar monitor sehingga diperoleh hasil berupa

  4. Construction of average adult Japanese voxel phantoms for dose assessment

    International Nuclear Information System (INIS)

    Sato, Kaoru; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira

    2011-12-01

    The International Commission on Radiological Protection (ICRP) adopted the adult reference voxel phantoms based on the physiological and anatomical reference data of Caucasian on October, 2007. The organs and tissues of these phantoms were segmented on the basis of ICRP Publication 103. In future, the dose coefficients for internal dose and dose conversion coefficients for external dose calculated using the adult reference voxel phantoms will be widely used for the radiation protection fields. On the other hand, the body sizes and organ masses of adult Japanese are generally smaller than those of adult Caucasian. In addition, there are some cases that the anatomical characteristics such as body sizes, organ masses and postures of subjects influence the organ doses in dose assessment for medical treatments and radiation accident. Therefore, it was needed to use human phantoms with average anatomical characteristics of Japanese. The authors constructed the averaged adult Japanese male and female voxel phantoms by modifying the previously developed high-resolution adult male (JM) and female (JF) voxel phantoms. It has been modified in the following three aspects: (1) The heights and weights were agreed with the Japanese averages; (2) The masses of organs and tissues were adjusted to the Japanese averages within 10%; (3) The organs and tissues, which were newly added for evaluation of the effective dose in ICRP Publication 103, were modeled. In this study, the organ masses, distances between organs, specific absorbed fractions (SAFs) and dose conversion coefficients of these phantoms were compared with those evaluated using the ICRP adult reference voxel phantoms. This report provides valuable information on the anatomical and dosimetric characteristics of the averaged adult Japanese male and female voxel phantoms developed as reference phantoms of adult Japanese. (author)

  5. Fast Biological Modeling for Voxel-based Heavy Ion Treatment Planning Using the Mechanistic Repair-Misrepair-Fixation Model and Nuclear Fragment Spectra

    Energy Technology Data Exchange (ETDEWEB)

    Kamp, Florian [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Department of Radiation Oncology, Technische Universität München, Klinikum Rechts der Isar, München (Germany); Physik-Department, Technische Universität München, Garching (Germany); Cabal, Gonzalo [Experimental Physics–Medical Physics, Ludwig Maximilians University Munich, Garching (Germany); Mairani, Andrea [Medical Physics Unit, Centro Nazionale Adroterapia Oncologica (CNAO), Pavia (Italy); Heidelberg Ion-Beam Therapy Center, Heidelberg (Germany); Parodi, Katia [Experimental Physics–Medical Physics, Ludwig Maximilians University Munich, Garching (Germany); Wilkens, Jan J. [Department of Radiation Oncology, Technische Universität München, Klinikum Rechts der Isar, München (Germany); Physik-Department, Technische Universität München, Garching (Germany); Carlson, David J., E-mail: david.j.carlson@yale.edu [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States)

    2015-11-01

    Purpose: The physical and biological differences between heavy ions and photons have not been fully exploited and could improve treatment outcomes. In carbon ion therapy, treatment planning must account for physical properties, such as the absorbed dose and nuclear fragmentation, and for differences in the relative biological effectiveness (RBE) of ions compared with photons. We combined the mechanistic repair-misrepair-fixation (RMF) model with Monte Carlo-generated fragmentation spectra for biological optimization of carbon ion treatment plans. Methods and Materials: Relative changes in double-strand break yields and radiosensitivity parameters with particle type and energy were determined using the independently benchmarked Monte Carlo damage simulation and the RMF model to estimate the RBE values for primary carbon ions and secondary fragments. Depth-dependent energy spectra were generated with the Monte Carlo code FLUKA for clinically relevant initial carbon ion energies. The predicted trends in RBE were compared with the published experimental data. Biological optimization for carbon ions was implemented in a 3-dimensional research treatment planning tool. Results: We compared the RBE and RBE-weighted dose (RWD) distributions of different carbon ion treatment scenarios with and without nuclear fragments. The inclusion of fragments in the simulations led to smaller RBE predictions. A validation of RMF against measured cell survival data reported in published studies showed reasonable agreement. We calculated and optimized the RWD distributions on patient data and compared the RMF predictions with those from other biological models. The RBE values in an astrocytoma tumor ranged from 2.2 to 4.9 (mean 2.8) for a RWD of 3 Gy(RBE) assuming (α/β){sub X} = 2 Gy. Conclusions: These studies provide new information to quantify and assess uncertainties in the clinically relevant RBE values for carbon ion therapy based on biophysical mechanisms. We present results from

  6. Application of the Oral Minimal Model to Korean Subjects with Normal Glucose Tolerance and Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Min Hyuk Lim

    2016-06-01

    Full Text Available BackgroundThe oral minimal model is a simple, useful tool for the assessment of β-cell function and insulin sensitivity across the spectrum of glucose tolerance, including normal glucose tolerance (NGT, prediabetes, and type 2 diabetes mellitus (T2DM in humans.MethodsPlasma glucose, insulin, and C-peptide levels were measured during a 180-minute, 75-g oral glucose tolerance test in 24 Korean subjects with NGT (n=10 and T2DM (n=14. The parameters in the computational model were estimated, and the indexes for insulin sensitivity and β-cell function were compared between the NGT and T2DM groups.ResultsThe insulin sensitivity index was lower in the T2DM group than the NGT group. The basal index of β-cell responsivity, basal hepatic insulin extraction ratio, and post-glucose challenge hepatic insulin extraction ratio were not different between the NGT and T2DM groups. The dynamic, static, and total β-cell responsivity indexes were significantly lower in the T2DM group than the NGT group. The dynamic, static, and total disposition indexes were also significantly lower in the T2DM group than the NGT group.ConclusionThe oral minimal model can be reproducibly applied to evaluate β-cell function and insulin sensitivity in Koreans.

  7. A study of Korean students' creativity in science using structural equation modeling

    Science.gov (United States)

    Jo, Son Mi

    Through the review of creativity research I have found that studies lack certain crucial parts: (a) a theoretical framework for the study of creativity in science, (b) studies considering the unique components related to scientific creativity, and (c) studies of the interactions among key components through simultaneous analyses. The primary purpose of this study is to explore the dynamic interactions among four components (scientific proficiency, intrinsic motivation, creative competence, context supporting creativity) related to scientific creativity under the framework of scientific creativity. A total of 295 Korean middle school students participated. Well-known and commonly used measurements were selected and developed. Two scientific achievement scores and one score measured by performance-based assessment were used to measure student scientific knowledge/inquiry skills. Six items selected from the study of Lederman, Abd-El-Khalick, Bell, and Schwartz (2002) were used to assess how well students understand the nature of science. Five items were selected from the subscale of the scientific attitude inventory version II (Moore & Foy, 1997) to assess student attitude toward science. The Test of Creative Thinking-Drawing Production (Urban & Jellen, 1996) was used to measure creative competence. Eight items chosen from the 15 items of the Work Preference Inventory (1994) were applied to measure students' intrinsic motivation. To assess the level of context supporting creativity, eight items were adapted from measurement of the work environment (Amabile, Conti, Coon, Lazenby, and Herron, 1996). To assess scientific creativity, one open-ended science problem was used and three raters rated the level of scientific creativity through the Consensual Assessment Technique (Amabile, 1996). The results show that scientific proficiency and creative competence correlates with scientific creativity. Intrinsic motivation and context components do not predict scientific

  8. Genetic parameters of calving ease using sire-maternal grandsire model in Korean Holsteins

    Directory of Open Access Journals (Sweden)

    Mahboob Alam

    2017-09-01

    Full Text Available Objective Calving ease (CE is a complex reproductive trait of economic importance in dairy cattle. This study was aimed to investigate the genetic merits of CE for Holsteins in Korea. Methods A total of 297,614 field records of CE, from 2000 to 2015, from first parity Holstein heifers were recorded initially. After necessary data pruning such as age at first calving (18 to 42 mo, gestation length, and presence of sire information, final datasets for CE consisted of 147,526 and 132,080 records for service sire calving ease (SCE and daughter calving ease (DCE evaluations, respectively. The CE categories were ordered and scores ranged from CE1 to CE5 (CE1, easy; CE2, slight assistance; CE3, moderate assistance; CE4, difficult calving; CE5, extreme difficulty calving. A linear transformation of CE score was obtained on each category using Snell procedure, and a scaling factor was applied to attain the spread between 0 (CE5 and 100% (CE1. A sire-maternal grandsire model analysis was performed using ASREML 3.0 software package. Results The estimated direct heritability (h2 from SCE and DCE evaluations were 0.11±0.01 and 0.08±0.01, respectively. Maternal h2 estimates were 0.05±0.02 and 0.04±0.01 from SCE and DCE approaches, respectively. Estimates of genetic correlations between direct and maternal genetic components were −0.68±0.09 (SCE and −0.71±0.09 (DCE. The average direct genetic effect increased over time, whereas average maternal effect was low and consistent. The estimated direct predicted transmitting ability (PTA was desirable and increasing over time, but the maternal PTA was undesirable and decreasing. Conclusion The evidence on sufficient genetic variances in this study could reflect a possible selection improvement over time regarding ease of calving. It is expected that the estimated genetic parameters could be a valuable resource to formulate sire selection and breeding plans which would be directed towards the reduction of

  9. Spatial averaging of fields from half-wave dipole antennas and corresponding SAR calculations in the NORMAN human voxel model between 65 MHz and 2 GHz.

    Science.gov (United States)

    Findlay, R P; Dimbylow, P J

    2009-04-21

    If an antenna is located close to a person, the electric and magnetic fields produced by the antenna will vary in the region occupied by the human body. To obtain a mean value of the field for comparison with reference levels, the Institute of Electrical and Electronic Engineers (IEEE) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend spatially averaging the squares of the field strength over the height the body. This study attempts to assess the validity and accuracy of spatial averaging when used for half-wave dipoles at frequencies between 65 MHz and 2 GHz and distances of lambda/2, lambda/4 and lambda/8 from the body. The differences between mean electric field values calculated using ten field measurements and that of the true averaged value were approximately 15% in the 600 MHz to 2 GHz range. The results presented suggest that the use of modern survey equipment, which takes hundreds rather than tens of measurements, is advisable to arrive at a sufficiently accurate mean field value. Whole-body averaged and peak localized SAR values, normalized to calculated spatially averaged fields, were calculated for the NORMAN voxel phantom. It was found that the reference levels were conservative for all whole-body SAR values, but not for localized SAR, particularly in the 1-2 GHz region when the dipole was positioned very close to the body. However, if the maximum field is used for normalization of calculated SAR as opposed to the lower spatially averaged value, the reference levels provide a conservative estimate of the localized SAR basic restriction for all frequencies studied.

  10. Modeling lifetime costs and health outcomes attributable to secondhand smoke exposure at home among Korean adult women.

    Science.gov (United States)

    Lee, Jiyae; Han, Ah Ram; Choi, Dalwoong; Lim, Kyung-Min; Bae, SeungJin

    2017-05-17

    The aim of this research is to estimate lifetime costs and health consequences for Korean adult women who were exposed to secondhand smoke (SHS) at home. A Markov model was developed to project the lifetime healthcare costs and health outcomes of a hypothetical cohort of Korean women who are 40 years old and were married to current smokers. The Korean epidemiological data were used to reflect the natural history of SHS-exposed and non-exposed women. The direct healthcare costs (in 2014 US dollars) and quality-adjusted life years (QALYs) were annually discounted at 5% to reflect time preference. The time horizon of the analysis was lifetime and the cycle length was 1 year. Deterministic and probabilistic sensitivity analyses were conducted. In the absence of SHS exposure, Korean women will live 41.32 years or 34.56 QALYs before discount, which corresponded to 17.29 years or 15.35 QALYs after discount. The SHS-exposed women were predicted to live 37.91 years and 31.08 QALYs before discount and 16.76 years and 14.62 QALYs after discount. The estimated lifetime healthcare cost per woman in the SHS non-exposed group was US$11 214 before the discount and US$2465 after discount. The negative impact of SHS exposure on health outcomes and healthcare costs escalated as the time horizon increased, suggesting that the adverse impact of SHS exposure may have higher impact on the later part of the lifetime. The result was consistent across a wide range of assumptions. Life expectancy might underestimate the impact of SHS exposure on health outcomes, especially if the time horizon of the analysis is not long enough. Early intervention on smoking behaviour could substantially reduce direct healthcare costs and improve quality of life attributable to SHS exposure. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. The integrated model of smartphone adoption: hedonic and utilitarian value perceptions of smartphones among Korean college students.

    Science.gov (United States)

    Chun, Heasun; Lee, Hyunjoo; Kim, Daejoong

    2012-09-01

    This study aims to propose an integrated model of smartphone adoption that incorporates social influences (SIs), perceived technicality, as well as hedonic and utilitarian attitudes into the technology acceptance model. The proposed model was empirically evaluated by using survey data collected from 239 Korean college students to investigate their perception and attitudes toward smartphone adoption intention. Our results show that users' attitudes and their adoption intention are highly influenced by SI and positive self-image. This implies that a smartphone is a symbolic product that can signal affiliation and enhance the users' status in a group. The results also indicate that hedonic enjoyment is equally important as utilitarian usefulness in predicting the adoption intention, and the two variables mediate the relationships between SI, positive self-image, perceived technicality, and the intention to use. Consequently, the results reveal that smartphones are convergent media that can be viewed as both task-oriented and entertainment-oriented devices.

  12. Comparison of applicability of current transition temperature shift models to SA533B-1 reactor pressure vessel steel of Korean nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Lee, Bong Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-08-15

    The precise prediction of radiation embrittlement of aged reactor pressure vessels (RPVs) is a prerequisite for the long-term operation of nuclear power plants beyond their original design life. The expiration of the operation licenses for Korean reactors the RPVs of which are made from SA533B-1 plates and welds is imminent. Korean regulatory rules have adopted the US Nuclear Regulatory Commission's transition temperature shift (TTS) models to the prediction of the embrittlement of Korean reactor pressure vessels. The applicability of the TTS model to predict the embrittlement of Korean RPVs made of SA533B-1 plates and welds was investigated in this study. It was concluded that the TTS model of 10 CFR 50.61a matched the trends of the radiation embrittlement in the SA533B-1 plates and welds better than did that of Regulatory Guide (RG) 1.99 Rev. 2. This is attributed to the fact that the prediction performance of 10 CFR 50.61a was enhanced by considering the difference in radiation embrittlement sensitivity among the different types of RPV materials.

  13. Predicted Water and Carbon Fluxes as well as Vegetation Distribution on the Korean Peninsula in the Future with the Ecosystem Demography Model version 2

    Science.gov (United States)

    Kim, J. B.; Kim, Y.

    2017-12-01

    This study investigates how the water and carbon fluxes as well as vegetation distribution on the Korean peninsula would vary with climate change. Ecosystem Demography (ED) Model version 2 (ED2) is used in this study, which is an integrated terrestrial biosphere model that can utilize a set of size- and age- structured partial differential equations that track the changing structure and composition of the plant canopy. With using the vegetation distribution data of Jeju Island, located at the southern part of the Korean Peninsula, ED2 is setup and driven for the past 10 years. Then the results of ED2 are evaluated and adjusted with observed forestry data, i.e., growth and mortality, and the flux tower and MODIS satellite data, i.e., evapotranspiration (ET) and gross primary production (GPP). This adjusted ED2 are used to simulate the water and carbon fluxes as well as vegetation dynamics in the Korean Peninsula for the historical period with evaluating the model against the MODIS satellite data. Finally, the climate scenarios of RCP 2.6 and 6.0 are used to predict the fluxes and vegetation distribution of the Korean Peninsula in the future. With using the state-of-art terrestrial ecosystem model, this study would provide us better understanding of the future ecosystem vulnerability of the Korean Peninsula. AcknowledgementsThis work was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (2015R1C1A2A01054800) and by the Korea Meteorological Administration R&D Program under Grant KMIPA 2015-6180. This work was also supported by the Yonsei University Future-leading Research Initiative of 2015(2016-22-0061).

  14. Loss, Psychosis, and Chronic Suicidality in a Korean American Immigrant Man: Integration of Cultural Formulation Model and Multicultural Case Conceptualization

    Science.gov (United States)

    Shea, Munyi; Yang, Lawrence H.; Leong, Frederick T. L.

    2011-01-01

    Culture shapes the nature, experience, and expression of psychopathology and help-seeking behavior across ethnically diverse groups. Although the study of psychopathology among Asian Americans has advanced, clinicians remain in need of culturally appropriate tools for the assessment and diagnosis of severe mental disorders including psychotic symptoms among Asian Americans. In this article, we present a brief overview of two culturally relevant conceptual tools: a) the Cultural Formulation Model, and b) the Multicultural Case Conceptualization approach. We use a case scenario to illustrate the integration of these two approaches in providing culturally responsive clinical conceptualization, assessment and treatment of a Korean American immigrant suffering from prominent psychiatric symptoms. We intend this discussion to engender further empirical work to advance our knowledge of the manifestation and experience of severe mental illness including psychotic disorders among Asian Americans, and contribute to culturally competent prevention and intervention of chronic and persistent mental illness within this group. PMID:21603157

  15. Vertical integration and market power: A model-based analysis of restructuring in the Korean electricity market

    International Nuclear Information System (INIS)

    Bunn, Derek W.; Martoccia, Maria; Ochoa, Patricia; Kim, Haein; Ahn, Nam-Sung; Yoon, Yong-Beom

    2010-01-01

    An agent-based simulation model is developed using computational learning to investigate the impact of vertical integration between electricity generators and retailers on market power in a competitive wholesale market setting. It is observed that if partial vertical integration creates some market foreclosure, whether this leads to an increase or decrease in market power is situation specific. A detailed application to the Korean market structure reveals this to be the case. We find that in various cases, whilst vertical integration generally reduces spot prices, it can increase or decrease the market power of other market generators, depending upon the market share and the technology segment of the market, which is integrated, as well as the market concentrations before and after the integration.

  16. Vertical integration and market power. A model-based analysis of restructuring in the Korean electricity market

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Derek W.; Martoccia, Maria; Ochoa, Patricia [London Business School, London (United Kingdom); Kim, Haein; Ahn, Nam-Sung; Yoon, Yong-Beom [Korean Electric Power Corporation, Seoul (Korea)

    2010-07-15

    An agent-based simulation model is developed using computational learning to investigate the impact of vertical integration between electricity generators and retailers on market power in a competitive wholesale market setting. It is observed that if partial vertical integration creates some market foreclosure, whether this leads to an increase or decrease in market power is situation specific. A detailed application to the Korean market structure reveals this to be the case. We find that in various cases, whilst vertical integration generally reduces spot prices, it can increase or decrease the market power of other market generators, depending upon the market share and the technology segment of the market, which is integrated, as well as the market concentrations before and after the integration. (author)

  17. Vertical integration and market power: A model-based analysis of restructuring in the Korean electricity market

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Derek W., E-mail: dbunn@london.ed [London Business School, London (United Kingdom); Martoccia, Maria; Ochoa, Patricia [London Business School, London (United Kingdom); Kim, Haein; Ahn, Nam-Sung; Yoon, Yong-Beom [Korean Electric Power Corporation, Seoul (Korea, Republic of)

    2010-07-15

    An agent-based simulation model is developed using computational learning to investigate the impact of vertical integration between electricity generators and retailers on market power in a competitive wholesale market setting. It is observed that if partial vertical integration creates some market foreclosure, whether this leads to an increase or decrease in market power is situation specific. A detailed application to the Korean market structure reveals this to be the case. We find that in various cases, whilst vertical integration generally reduces spot prices, it can increase or decrease the market power of other market generators, depending upon the market share and the technology segment of the market, which is integrated, as well as the market concentrations before and after the integration.

  18. Extending a structural model of somatization to South Koreans: Cultural values, somatization tendency, and the presentation of depressive symptoms.

    Science.gov (United States)

    Zhou, Xiaolu; Min, Seongho; Sun, Jiahong; Kim, Se Joo; Ahn, Joung-Sook; Peng, Yunshi; Noh, Samuel; Ryder, Andrew G

    2015-05-01

    Somatization refers to the tendency to emphasize somatic symptoms when experiencing a psychiatric disturbance. This tendency has been widely reported in patients from East Asian cultural contexts suffering from depression. Recent research in two Chinese samples have demonstrated that the local cultural script for depression, involving two aspects-the experience and expression of distress (EED) and conceptualization and communication of distress (CCD)-can be evoked to help explain somatization. Given the beliefs and practices broadly shared across Chinese and South Korean cultural contexts, the current study seeks to replicate this explanatory model in South Koreans. Our sample included 209 psychiatric outpatients from Seoul and Wonju, South Korea. Self-report questionnaires were used to assess somatization tendency, adherence to traditional values, and psychological and somatic symptoms of depression. Results from SEM showed that the EED and CCD factors of somatization tendency were differently associated with cultural values and somatic symptoms, replicating our previous findings in Chinese outpatients. The reliance on a brief self-report measure of somatization tendency, not originally designed to assess separate EED and CCD factors, highlights the need for measurement tools for the assessment of cultural scripts in cross-cultural depression research. The replication of the Chinese structural model of somatization in South Korea lends empirical support to the view that somatization can be understood as the consequence of specific cultural scripts. These scripts involve the experience and expression of distress as well as culturally meaningful ways in which this distress is conceptualized and communicated to others. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Hyeong; Jeong, Jong Hwi [Department of Nuclear Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Bolch, Wesley E [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Cho, Kun-Woo [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Hwang, Sung Bae, E-mail: chkim@hanyang.ac.kr [Department of Physical Therapy, Kyungbuk College, Hyucheon 2-dong, Yeongju-si, Gyeongbuk 750-712 (Korea, Republic of)

    2011-05-21

    Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

  20. A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kim, Chan Hyeong; Jeong, Jong Hwi; Bolch, Wesley E; Cho, Kun-Woo; Hwang, Sung Bae

    2011-01-01

    Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

  1. Korea's "Model Minority": A Case Study of an American-Korean Bilingual Student's Challenges Learning English in South Korea

    Science.gov (United States)

    Schenck, Andrew D.

    2013-01-01

    In contemporary South Korean society, there is a strong emphasis on cultural homogeneity and, simultaneously, the development of English proficiency as a human resource. Since language is inextricably linked to identity, bilingual learners from English speaking countries may feel pressure to conform to Korean cultural and linguistic norms, leading…

  2. Comparing the Nordic and South Korean Models: Labour-Market Regulation and Social Welfare in Times of Crisis

    DEFF Research Database (Denmark)

    Schmidt, Johannes Dragsbæk

    2012-01-01

    The first part of the paper briefly describes the causes and impacts of the US induced financial crisis cum “Great Depression”. The second part discusses the status of the various models of contemporary capitalism – the discredited Anglo-Saxon finance-driven model versus the export-driven product......The first part of the paper briefly describes the causes and impacts of the US induced financial crisis cum “Great Depression”. The second part discusses the status of the various models of contemporary capitalism – the discredited Anglo-Saxon finance-driven model versus the export......-driven production model of growth, with weak safety nets, adopted by East Asian countries in contrast to the export-oriented Nordic social welfare model. The third section documents the impact of the crisis on the economies, and discusses core examples of state intervention in the socio-economic sectors...... such as labor markets and social welfare in the Nordic as well as Korean contexts. The final section discusses some tentative conclusions about the resilience of the Nordic and ROK models and their potential for recovery....

  3. Effect of phantom voxelization in CT simulations

    International Nuclear Information System (INIS)

    Goertzen, Andrew L.; Beekman, Freek J.; Cherry, Simon R.

    2002-01-01

    In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 10 3 -10 7 photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel

  4. The role of nuclear energy for Korean long-term energy supply strategy : application of energy demand-supply model

    International Nuclear Information System (INIS)

    Chae, Kyu Nam

    1995-02-01

    An energy demand and supply analysis is carried out to establish the future nuclear energy system of Korea in the situation of environmental restriction and resource depletion. Based on the useful energy intensity concept, a long-term energy demand forecasting model FIN2USE is developed to integrate with a supply model. The energy supply optimization model MESSAGE is improved to evaluate the role of nuclear energy system in Korean long-term energy supply strategy. Long-term demand for useful energy used as an exogeneous input of the energy supply model is derived from the trend of useful energy intensity by sectors and energy carriers. Supply-side optimization is performed for the overall energy system linked with the reactor and nuclear fuel cycle strategy. The limitation of fossil fuel resources and the CO 2 emission constraints are reflected as determinants of the future energy system. As a result of optimization of energy system using linear programming with the objective of total discounted system cost, the optimal energy system is obtained with detailed results on the nuclear sector for various scenarios. It is shown that the relative importance of nuclear energy would increase especially in the cases of CO 2 emission constraint. It is concluded that nuclear reactor strategy and fuel cycle strategy should be incorporated with national energy strategy and be changed according to environmental restriction and energy demand scenarios. It is shown that this modelling approach is suitable for a decision support system of nuclear energy policy

  5. A Development of Nonstationary Regional Frequency Analysis Model with Large-scale Climate Information: Its Application to Korean Watershed

    Science.gov (United States)

    Kim, Jin-Young; Kwon, Hyun-Han; Kim, Hung-Soo

    2015-04-01

    The existing regional frequency analysis has disadvantages in that it is difficult to consider geographical characteristics in estimating areal rainfall. In this regard, this study aims to develop a hierarchical Bayesian model based nonstationary regional frequency analysis in that spatial patterns of the design rainfall with geographical information (e.g. latitude, longitude and altitude) are explicitly incorporated. This study assumes that the parameters of Gumbel (or GEV distribution) are a function of geographical characteristics within a general linear regression framework. Posterior distribution of the regression parameters are estimated by Bayesian Markov Chain Monte Carlo (MCMC) method, and the identified functional relationship is used to spatially interpolate the parameters of the distributions by using digital elevation models (DEM) as inputs. The proposed model is applied to derive design rainfalls over the entire Han-river watershed. It was found that the proposed Bayesian regional frequency analysis model showed similar results compared to L-moment based regional frequency analysis. In addition, the model showed an advantage in terms of quantifying uncertainty of the design rainfall and estimating the area rainfall considering geographical information. Finally, comprehensive discussion on design rainfall in the context of nonstationary will be presented. KEYWORDS: Regional frequency analysis, Nonstationary, Spatial information, Bayesian Acknowledgement This research was supported by a grant (14AWMP-B082564-01) from Advanced Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government.

  6. Reconstruction of segmented human voxel phantoms for skin dosimetry

    International Nuclear Information System (INIS)

    Antunes, Paula C.G.; Siqueira, Paulo de Tarso D.; Yoriyaz, Helio; Fonseca, Gabriel P.; Reis, Gabriela; Furnari, Laura

    2009-01-01

    High-resolution medical images along with methods that simulate the interaction of radiation with matter, as the Monte Carlo radiation transport codes, have been widely used in medical physics procedures. These images provide the construction of realistic anatomical models, which after being coupled to these codes, may drive to better assessments of dose distributions on the patient. These anatomical models constructed from medical images are known as voxel phantoms (voxel - volume element of an image). Present day regular images are unsuitable to correctly perform skin dose distribution evaluations. This inability is due to improper skin discrimination in most of the current medical images, once its thickness stands below the resolution of the pixels that form the image. This paper proposes the voxel phantom reconstruction by subdividing and segmenting the elements that form the phantom. It is done in order to better discriminate the skin by assigning it more adequate thickness and actual location, allowing a better dosimetric evaluation of the skin. This task is an important issue in many radiotherapy procedures. Particular interest lays in Total Skin Irradiation (TSI) with electron beams, where skin dose evaluation stands as the treatment key point of the whole body irradiation. This radiotherapy procedure is under implementation at the Hospital das Clinicas da Universidade de Sao Paulo (HC-USP). (author)

  7. Development of new NSSS thermal-hydraulic model for Korean standard nuclear power plant(UCN-3/4) simulator

    International Nuclear Information System (INIS)

    Kim, Kyung Doo; Jeong, Jae Jun

    2001-09-01

    The NSSS thermal-hydraulic programs installed in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited computational capability at that time, they usually adopt very simplified physical models for a real-time simulation of NSSS thermal-hydraulic phenomena, which entails inaccurate results and the possibility of so-called 'negative training', especially for complicated two-phase flows in the reactor coolant system. To resolve the problem, we developed a realistic NSSS T/H program (named 'ARTS-UCN' code) for the improvement of the Korean Standard Nuclear Power Plant full-scope simulator. ARTS Code, developed as an NSSS T/H model for the KNPEC no. 2 simulator using the RETRAN03 code, was selected as a reference code for ARTS-UCN code development. For the development of ARTS, the followings have been performed: - Improvement of the robustness of RETRAN - Improvement of the real-time simulation capability of RETRAN - Optimum input data generation for the NSSS simulation - New model development that cannot be efficiently modeled by RETRAN - Assessment of the ARTS code. The systematic assessment of ARTS has been conducted in both personal computers (Windows 98, Visual fortran) and the simulator development environment (Windows NT, GSE simulator development tool). The results were resonable in terms of accuracy, real-time simulation and robustness

  8. Inner and outer coronary vessel wall segmentation from CCTA using an active contour model with machine learning-based 3D voxel context-aware image force

    Science.gov (United States)

    Sivalingam, Udhayaraj; Wels, Michael; Rempfler, Markus; Grosskopf, Stefan; Suehling, Michael; Menze, Bjoern H.

    2016-03-01

    In this paper, we present a fully automated approach to coronary vessel segmentation, which involves calcification or soft plaque delineation in addition to accurate lumen delineation, from 3D Cardiac Computed Tomography Angiography data. Adequately virtualizing the coronary lumen plays a crucial role for simulating blood ow by means of fluid dynamics while additionally identifying the outer vessel wall in the case of arteriosclerosis is a prerequisite for further plaque compartment analysis. Our method is a hybrid approach complementing Active Contour Model-based segmentation with an external image force that relies on a Random Forest Regression model generated off-line. The regression model provides a strong estimate of the distance to the true vessel surface for every surface candidate point taking into account 3D wavelet-encoded contextual image features, which are aligned with the current surface hypothesis. The associated external image force is integrated in the objective function of the active contour model, such that the overall segmentation approach benefits from the advantages associated with snakes and from the ones associated with machine learning-based regression alike. This yields an integrated approach achieving competitive results on a publicly available benchmark data collection (Rotterdam segmentation challenge).

  9. A goodness of fit and validity study of the Korean radiological technologists' core job competency model

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chang Seon [Dept. of Radiological Science, Konyang University College of Medical Sciences, Daejeon (Korea, Republic of); Cho, A Ra [Dept. of Medical Education, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Hur, Yera [Dept. of Medical Education, Konyang University College of Medicine, Daejeon (Korea, Republic of); Choi, Seong Youl [Dept. of Occupational Therapy, Kwangju women’s University, Gwangju (Korea, Republic of)

    2017-09-15

    Radiological Technologists deals with the life of a person which means professional competency is essential for the job. Nevertheless, there have been no studies in Korea that identified the job competence of radiologists. In order to define the core job competencies of Korean radiologists and to present the factor models, 147 questionnaires on job competency of radiology were analyzed using 'PASW Statistics Version 18.0' and 'AMOS Version 18.0'. The valid model consisted of five core job competencies ('Patient management', 'Health and safety', 'Operation of equipment', 'Procedures and management') and 17 sub – competencies. As a result of the factor analysis, the RMSEA value was 0.1 and the CFI, and TLI values were close to 0.9 in the measurement model of the five core job competencies. The validity analysis showed that the mean variance extraction was 0.5 or more and the conceptual reliability value was 0.7 or more , And there was a high correlation between subordinate competencies included in each subordinate competencies. The results of this study are expected to provide specific information necessary for the training and management of human resources centered on competence by clearly showing the job competence required for radiologists in Korea's health environment.

  10. The Korean herbal formulation Yukmijihwangtang stimulates longitudinal bone growth in animal models.

    Science.gov (United States)

    Cho, Sung-Min; Lee, Sun Haeng; Lee, Donghun; Lee, Ji Hong; Chang, Gyu Tae; Kim, Hocheol; Lee, Jin Yong

    2017-05-02

    Yukmijihwangtang (YJT) is a traditional Korean medicine that has been used to treat kidney-yin deficiency symptoms such as dizziness and tinnitus. In addition, because it is also thought to nourish kidney-yin, it has been used to treat short stature from congenital deficiency. This study evaluated the effects of YJT on longitudinal bone growth in rats. Female adolescent rats were randomly assigned to groups that received distilled water (per os [p.o.] twice a day; control), recombinant human growth hormone (rhGH; 20 μg/kg, subcutaneous [s.c.] once a day), or two different doses of YJT (100 or 300 mg/kg, p.o. twice a day). In each group, treatment was maintained for 4 days. Rats were injected intraperitoneally with 5-bromo-2'-deoxyuridine (BrdU; 50 mg/kg) to label proliferating chondrocytes on days 2 - 4. Tetracycline hydrochloride (20 mg/kg) was injected intraperitoneally to form fluorescent bands on the growth plates on day 3 for measuring the longitudinal bone growth rate. Expression of insulin-like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in the growth plate was identified using immunohistochemistry. There was a significant increase in the rate of bone growth in the 300 mg/kg YJT group (523.8 ± 23.7 μm/day; P growth plate in the 300 mg/kg YJT and rhGH groups. YJT increased the longitudinal bone growth rate by stimulating chondrocyte proliferation with increasing increments of local IGF-1 and BMP-2 expression. Based on these findings, YJT may be a therapeutic candidate for the treatment of growth retardation during adolescence.

  11. Analytical modeling and feasibility study of a multi-GPU cloud-based server (MGCS) framework for non-voxel-based dose calculations.

    Science.gov (United States)

    Neylon, J; Min, Y; Kupelian, P; Low, D A; Santhanam, A

    2017-04-01

    In this paper, a multi-GPU cloud-based server (MGCS) framework is presented for dose calculations, exploring the feasibility of remote computing power for parallelization and acceleration of computationally and time intensive radiotherapy tasks in moving toward online adaptive therapies. An analytical model was developed to estimate theoretical MGCS performance acceleration and intelligently determine workload distribution. Numerical studies were performed with a computing setup of 14 GPUs distributed over 4 servers interconnected by a 1 Gigabits per second (Gbps) network. Inter-process communication methods were optimized to facilitate resource distribution and minimize data transfers over the server interconnect. The analytically predicted computation time predicted matched experimentally observations within 1-5 %. MGCS performance approached a theoretical limit of acceleration proportional to the number of GPUs utilized when computational tasks far outweighed memory operations. The MGCS implementation reproduced ground-truth dose computations with negligible differences, by distributing the work among several processes and implemented optimization strategies. The results showed that a cloud-based computation engine was a feasible solution for enabling clinics to make use of fast dose calculations for advanced treatment planning and adaptive radiotherapy. The cloud-based system was able to exceed the performance of a local machine even for optimized calculations, and provided significant acceleration for computationally intensive tasks. Such a framework can provide access to advanced technology and computational methods to many clinics, providing an avenue for standardization across institutions without the requirements of purchasing, maintaining, and continually updating hardware.

  12. Self-transcendence, spiritual perspective, and sense of purpose in family caregiving relationships: a mediated model of depression symptoms in Korean older adults.

    Science.gov (United States)

    Kim, Suk-Sun; Hayward, R David; Reed, Pamela G

    2014-09-01

    This study used structural equation modeling to test the mediated model of late-life depression to understand the mechanisms that account for the direct and indirect effects of spiritual variables and purpose in life on depression within the context of Korean family caregiving relationships. A secondary analysis study design used data from a study that tested a theory of family interdependence of 157 Korean elder-family caregiver dyads in Seoul, Korea. Both caregivers' and elders' self-transcendence was positively related to their own sense of purpose in life. However, only elders' spiritual perspective was related to purpose in life. Also, elders' purpose in life was positively associated with caregivers' purpose in life. Furthermore, there was a strong negative relationship between elders' purpose in life and their depressive symptoms, but there was not a significant negative relationship between caregivers' purpose in life and elders' depressive symptoms. Last, elders' purpose in life mediated the negative effects of elders' self-transcendence and spiritual perspective and of caregivers' self-transcendence and purpose in life on elders' depression. The findings suggest that purpose in life for both the caregiver and elder played an important role in elders' depression. Self-transcendence also was related to decreased depression in elders. It is suggested that more attention be given to caregiver and elder purpose in life in developing interventions to reduce or avoid elder depression in Korean elders.

  13. Acculturation and Health of Korean American Adults.

    Science.gov (United States)

    Shin, Cha-Nam; Lach, Helen W

    2014-07-01

    Increasing cultural diversity in the United States and significant health disparities among immigrant populations make acculturation an important concept to measure in health research. The purpose of this cross-sectional, descriptive study was to examine acculturation and health of Korean American adults. A convenience sample of 517 Korean American adults in a Midwestern city completed a survey in either English or Korean. All four groups of Berry's acculturation model were identified using cluster analysis with Lee's Acculturation Scale. Assimilation, integration, and separation were found in the English survey sample, whereas integration, separation, and marginalization were found in the Korean survey sample. Moreover, the findings revealed that acculturation is a bidimensional process, and the unique nature of samples may determine acculturation groups. Physical health and mental health were significantly related to acculturation in the English survey sample. However, there was not a significant relationship between health and acculturation in the Korean survey sample. © The Author(s) 2014.

  14. History of Korean Neurosurgery.

    Science.gov (United States)

    Hwang, Sung-nam

    2015-08-01

    The year 2012 was the 50th anniversary of the Korean Neurosurgical Society, and in 2013, the 15th World Congress of Neurosurgery took place in Seoul, Korea. Thus, it is an appropriate occasion to introduce the world to the history of the Korean Neurosurgical Society and the foundation, development, and growth of Korean neurosurgery. Historical materials and pictures were collected and reviewed from the history book and photo albums of the Korean Neurosurgical Society. During the last 50 years, the Korean Neurosurgical Society and Korean neurosurgery have developed and grown enormously not only in quantity but also in quality. In every aspect, the turning point from the old to the new era of the Korean Neurosurgical Society and Korean neurosurgery was the year 1980. Copyright © 2015. Published by Elsevier Inc.

  15. A Test Model in a RF Anechoic Chamber for the Application of Wi-Fi Communication in Korean Operating NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sik; Kim, Min Seok; Ryu, Ho Sun; Ye, Song Hae; Lee, Gwang Dae [KHNP, Daejeon (Korea, Republic of)

    2014-08-15

    The objective of this study is to make a test model and confirm its effectiveness in a radio frequency (RF) anechoic chamber before conducting a field test in Korean operating NPPs for use of Wi-Fi communication technology. This paper is focused on electromagnetic/radio-frequency interference (EMI/RFI) issue and discusses a methodology and its test result for overcoming that issue. Whenever wireless communication is performed between an access point (AP) and a smart phone, EMI/RFI problem always happens around those devices. It is necessary to decide how many wireless devices local workers will use and select what facilities and systems to protect from EMI/RFI, which are so-called EMI/RFI sensitive equipment. The number of wireless devices was decided as many as possible in the area where those devices could be used, and some sensitive equipment that shall not malfunction under electromagnetic environment were chosen. The test bed which considered above mentioned conditions was constructed and an experiment was carried out inside a radio-frequency anechoic chamber. Comparing with the allowable operating envelopes for electromagnetic level from RG-1.180, each maximum level of the test results acquired from a RF anechoic chamber is not over the limit even in case of considering the maximum local workers' usage. This result shows that it is highly likely that Wi-Fi communication can be used without any problem if sensitive equipment has observed the electromagnetic susceptibility limit of RG-1.180.

  16. Application of the Western-based adjuvant online model to Korean colon cancer patients; a single institution experience

    International Nuclear Information System (INIS)

    Jung, Minkyu; Shin, Sang Joon; Kim, Geon Woo; Jung, Inkyung; Ahn, Joong Bae; Roh, Jae Kyung; Rha, Sun Young; Chung, Hyun Cheol; Kim, Nam Kyu; Kim, Tae Il

    2012-01-01

    Adjuvant Online (AOL) is web-accessible risk-assessment model that predicts the mortality and the benefits of adjuvant therapy. AOL has never been validated for Asian colon cancer patients. Using the Yonsei Tumor Registry database, patients who were treated within the Yonsei University Health System between 1990 and 2005 for T1-4, N0-2, and M0 colon cancer were included in the calculations for survival. Observed and predicted 5-year overall survival was compared for each patient. The median age of the study population of 1431 patients was 60 years (range, 15–87 years), and the median follow-up duration was 7.9 years (range, 0.06–19.8 years). The predicted 5-year overall survival rate (77.7%) and observed survival (79.5%) was not statistically different (95% Confidential interval, 76.3–81.5) in all patients. Predicted outcomes were within 95% confidential interval of observed survival in both stage II and III disease, including most demographic and pathologic subgroups. Moreover, AOL more accurately predicted OS for patients with stage II than stage III. AOL tended to offer reliable prediction for 5-year overall survival and could be used as a decision making tool for adjuvant treatment in Korean colon cancer patients whose prognosis is similar to other Asian patients

  17. Proteomic Analysis of the Effect of Korean Red Ginseng in the Striatum of a Parkinson's Disease Mouse Model.

    Science.gov (United States)

    Kim, Dongsoo; Jeon, Hyongjun; Ryu, Sun; Koo, Sungtae; Ha, Ki-Tae; Kim, Seungtae

    2016-01-01

    Recent studies have shown that Korean Red Ginseng (KRG) suppresses dopaminergic neuronal death in the brain of a Parkinson's disease (PD) mouse model, but the mechanism is still elusive. Using a 2-dimensional electrophoresis technique, we investigated whether KRG can restore the changes in protein expressions in the striatum (ST) of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-injected mice. Male C57BL/6 mice (9 weeks old) were injected with 20 mg/kg MPTP intraperitoneally four times at 2-h intervals. KRG (100 mg/kg) was orally administered once a day for 3 days from one hour after the first MPTP injection. Two hours after the third KRG administration a pole test was performed to evaluate motor function, after which the brains were immediately harvested. Survival of dopaminergic neurons in the nigrostriatal pathway and protein expression in the ST were measured by immunohistochemistry and 2-dimensional electrophoresis. KRG suppressed MPTP-induced behavioral dysfunction and neuronal death in the nigrostriatal pathway. Moreover, 30 proteins changed by MPTP and KRG in the ST were identified and shown to be related to glycolysis/gluconeogenesis and neurodegenerative diseases including Alzheimer's disease and PD. KRG has neuroprotective effects against MPTP toxicity and alleviates protein expression profiles related to enhancing energy metabolism in the ST of MPTP-treated mice.

  18. The impact of voxel size-based inaccuracies on the mechanical behavior of thin bone structures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Whyne, Cari

    2011-03-01

    Computed tomography (CT)-based measures of skeletal geometry and material properties have been widely used to develop finite element (FE) models of bony structures. However, in the case of thin bone structures, the ability to develop FE models with accurate geometry derived from clinical CT data presents a challenge due to the thinness of the bone and the limited resolution of the imaging devices. The purpose of this study was to quantify the impact of voxel size on the thickness and intensity values of thin bone structure measurements and to assess the effect of voxel size on strains through FE modeling. Cortical bone thickness and material properties in five thin bone specimens were quantified at voxel sizes ranging from 16.4 to 488 μm. The measurements derived from large voxel size scans showed large increases in cortical thickness (61.9-252.2%) and large decreases in scan intensity (12.9-49.5%). Maximum principal strains from FE models generated using scans at 488 μm were decreased as compared to strains generated at 16.4 μm voxel size (8.6-64.2%). A higher level of significance was found in comparing intensity (p = 0.0001) vs. thickness (p = 0.005) to strain measurements. These findings have implications in developing methods to generate accurate FE models to predict the biomechanical behavior of thin bone structures.

  19. A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization

    International Nuclear Information System (INIS)

    Zarepisheh, Masoud; Uribe-Sanchez, Andres F.; Li, Nan; Jia, Xun; Jiang, Steve B.

    2014-01-01

    Purpose: To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. Methods: In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. Results: The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly

  20. Financial Restraints in the South Korean Miracle

    OpenAIRE

    Panicos O Demetriades; Kul B Luintel

    2000-01-01

    We provide novel empirical evidence on the effects of financial restraints on South Korean financial development. The evidence is linked to a simple model of the Korean banking system that encapsulates its cartelised nature, which predicts a positive association between financial development and (i) the degree of state control over the banking system, (ii) mild repression of lending rates. The model also predicts that in the presence of lending rate controls, increases in the level of the adm...

  1. Communication for end-of-life care planning among Korean patients with terminal cancer: A context-oriented model.

    Science.gov (United States)

    Koh, Su Jin; Kim, Shinmi; Kim, Jinshil

    2016-02-01

    In Korea, patients with terminal cancer are often caught out of the loop in end-of-life (EoL) care discussions. Healthcare professionals also have difficulty engaging in such communication in a variety of healthcare contexts. Therefore, the objective of our study was to develop a communication model for EoL care decision making compatible with the clinical environment in Korea. Using focus-group interview methodology, participants included eight doctors and five nurses who provide EoL care for terminal cancer patients in acute hospital settings or hospice care facilities in various provinces of Korea. Five themes emerged regarding EoL care discussion, which included: (1) timing, (2) responsible professionals, (3) disclosure of bad news, (4) content areas of EoL care discussion, and (5) implementing strategies for EoL care discussions. These themes were based on development of a communication algorithm for EoL discussion among patients with terminal cancer. A structural communication step for delivery of a terminal prognosis was specified at the phase of disclosure of bad news: beginning with determination of a patient's decision-making capability, followed by a patient's perception of his/her condition, a patient's wish to know, family dynamics, and a patient's and/or family's readiness for EoL discussions. The proposed context-oriented communication algorithm could provide a helpful guideline for EoL communication and, accordingly, facilitate meaningful improvements in EoL care in Korean clinical practice. The feasibility of this algorithm has not yet been determined, and its validation in a larger sample of patients with terminal cancers, using a quantitative research methodology, is a priority of research.

  2. Korean Confucianism's Mindful Learning Model of Moral Internalization as Manifested in the Cheonghak-Dong Hermit Community

    Science.gov (United States)

    Yoo, Si Ha

    2012-01-01

    The purpose of this qualitative study is to understand an unknown educational approach in Korean Confucianism's ethical education characterized as moral internalization, based on the study participants. A prevailed understanding of moral internalization of Confucianism is a strong imposed learning process, which is a well known Asian learning…

  3. Validation of periodontitis screening model using sociodemographic, systemic, and molecular information in a Korean population.

    Science.gov (United States)

    Kim, Hyun-Duck; Sukhbaatar, Munkhzaya; Shin, Myungseop; Ahn, Yoo-Been; Yoo, Wook-Sung

    2014-12-01

    This study aims to evaluate and validate a periodontitis screening model that includes sociodemographic, metabolic syndrome (MetS), and molecular information, including gingival crevicular fluid (GCF), matrix metalloproteinase (MMP), and blood cytokines. The authors selected 506 participants from the Shiwha-Banwol cohort: 322 participants from the 2005 cohort for deriving the screening model and 184 participants from the 2007 cohort for its validation. Periodontitis was assessed by dentists using the community periodontal index. Interleukin (IL)-6, IL-8, and tumor necrosis factor-α in blood and MMP-8, -9, and -13 in GCF were assayed using enzyme-linked immunosorbent assay. MetS was assessed by physicians using physical examination and blood laboratory data. Information about age, sex, income, smoking, and drinking was obtained by interview. Logistic regression analysis was applied to finalize the best-fitting model and validate the model using sensitivity, specificity, and c-statistics. The derived model for periodontitis screening had a sensitivity of 0.73, specificity of 0.85, and c-statistic of 0.86 (P validated model were 0.64, 0.91, and 0.83 (P <0.001), respectively. The model that included age, sex, income, smoking, drinking, and blood and GCF biomarkers could be useful in screening for periodontitis. A future prospective study is indicated for evaluating this model's ability to predict the occurrence of periodontitis.

  4. Modelling of and Conjecturing on a Soccer Ball in a Korean Eighth Grade Mathematics Classroom

    Science.gov (United States)

    Lee, Kyeong-Hwa

    2011-01-01

    The purpose of this article was to describe the task design and implementation of cultural artefacts in a mathematics lesson based on the integration of modelling and conjecturing perspectives. The conceived process of integrating a soccer ball into mathematics lessons via modelling- and conjecturing-based instruction was first detailed. Next, the…

  5. A Structural Equation Model on Korean Adolescents' Excessive Use of Smartphones.

    Science.gov (United States)

    Lee, Hana; Kim, JooHyun

    2018-03-31

    We develop a unified structural model that defines multi-relationships between systematic factors causing excessive use of smartphones and the corresponding results. We conducted a survey with adolescents who live in Seoul, Pusan, Gangneung, Donghae, and Samcheok from Feb. to Mar. 2016. We utilized SPSS Ver. 22 and Amos Ver. 22 to analyze the survey result at a 0.05 significance level. To investigate demographic characteristics of the participants and their variations, we employed descriptive analysis. We adopted the maximum likelihood estimate method to verify the fitness of the hypothetical model and the hypotheses therein. We used χ 2 statistics, GFI, AGFI, CFI, NFI, IFI, RMR, and RMSEA to verify the fitness of our structural model. (1) Our proposed structural model demonstrated a fine fitness level. (2) Our proposed structural model could describe the excessive use of a smartphone with 88.6% accuracy. (3) The absence of the family function and relationship between friends, impulsiveness, and low self-esteem were confirmed as key factors that cause excessive use of smartphones. (4) Further, impulsiveness and low self-esteem are closely related to the absence of family functions and relations between friends by 68.3% and 54.4%, respectively. We suggest that nursing intervention programs from various angles are required to reduce adolescents' excessive use of smartphones. For example, family communication programs would be helpful for both parents and children. Consultant programs about friend relationship also meaningful for the program. Copyright © 2018. Published by Elsevier B.V.

  6. How inequality hurts growth: Revisiting the Galor-Zeira model through a Korean case

    NARCIS (Netherlands)

    Jun, Bogang; Kaltenberg, Mary; Hwang, Won-sik

    2017-01-01

    This paper aims to show that the level of inequality increases via the human capital channel with credit market imperfections generating negative effects on economic growth. We expand the model presented by Galor and Zeira (1993) to represent the fact that the economy benefits from endogenous

  7. Comparison of the Usefulness of the Updated Homeostasis Model Assessment (HOMA2 with the Original HOMA1 in the Prediction of Type 2 Diabetes Mellitus in Koreans

    Directory of Open Access Journals (Sweden)

    Young Seok Song

    2016-05-01

    Full Text Available BackgroundThe original homeostasis model assessment (HOMA1 and the updated HOMA model (HOMA2 have been used to evaluate insulin resistance (IR and β-cell function, but little is known about the usefulness of HOMA2 for the prediction of diabetes in Koreans. The aim of this study was to demonstrate the usefulness of HOMA2 as a predictor of type 2 diabetes mellitus in Koreans without diabetes.MethodsThe study population consisted of 104,694 Koreans enrolled at a health checkup program and followed up from 2001 to 2012. Participants were divided into a normal glucose tolerance (NGT group and a pre-diabetes group according to fasting glucose and glycosylated hemoglobin levels. Anthropometric and laboratory data were measured at the baseline checkup, and HOMA values were calculated at the baseline and follow-up checkups. The hazard ratios (HRs of the HOMA1 and HOMA2 values and the prevalence of diabetes at follow-up were evaluated using a multivariable Cox proportional hazards model and Kaplan-Meier analysis.ResultsAfter adjusting for several diabetes risk factors, all of the HOMA values except 1/HOMA1-β and 1/HOMA2-β in the NGT group were significant predictors of the progression to diabetes. In the NGT group, there was no significant difference in HOMA1-IR (HR, 1.09; 95% confidence interval [CI], 1.04 to 1.14 and HOMA2-IR (HR, 1.11; 95% CI, 1.04 to 1.19. However, in the pre-diabetes group, 1/HOMA2-β was a more powerful marker (HR, 1.29; 95% CI, 1.26 to 1.31 than HOMA1-IR (HR, 1.23; 95% CI, 1.19 to 1.28 or 1/HOMA1-β (HR, 1.14; 95% CI, 1.12 to 1.16. In the non-diabetic group (NGT+pre-diabetes, 1/HOMA2-β was also a stronger predictor of diabetes (HR, 1.27; 95% CI, 1.25 to 1.29 than HOMA1-IR (HR, 1.14; 95% CI, 1.12 to 1.15 or 1/HOMA1-β (HR, 1.13; 95% CI, 1.11 to 1.14.ConclusionHOMA2 is more predictive than HOMA1 for the progression to diabetes in pre-diabetes or non-diabetic Koreans.

  8. Understanding Korean food culture from Korean paintings

    OpenAIRE

    Hae Kyung Chung; Kyung Rhan Chung; Hung Ju Kim

    2016-01-01

    Background: In Korea, there are many traditional foods that have developed along with the country's rich history. In addition, various food cultures have developed through agricultural traditions, ritual ceremonies, and the sharing of affection. Paintings, works of calligraphy, and music demonstrate some of these cultural characteristics of Korean foods. Further research and analysis of Korean food culture using these data sources is currently underway. Methods: This paper focuses on the c...

  9. Post-partum blues among Korean mothers: a structural equation modelling approach.

    Science.gov (United States)

    Chung, Sung Suk; Yoo, Il Young; Joung, Kyoung Hwa

    2013-08-01

    The objective of this study was to propose the post-partum blues (PPB) model and to estimate the effects of self-esteem, social support, antenatal depression, and stressful events during pregnancy on PPB. Data were collected from 249 women post-partum during their stay in the maternity units of three hospitals in Korea using a self-administered questionnaire. A structural equation modelling approach using the Analysis of Moments Structure program was used to identify the direct and indirect effects of the variables on PPB. The full model had a good fit and accounted for 70.3% of the variance of PPB. Antenatal depression and stressful events during pregnancy had strong direct effects on PPB. Household income showed indirect effects on PPB via self-esteem and antenatal depression. Social support indirectly affected PPB via self-esteem, antenatal depression, and stressful events during pregnancy. © 2012 The Authors; International Journal of Mental Health Nursing © 2012 Australian College of Mental Health Nurses Inc.

  10. A hybrid hydrologically complemented warning model for shallow landslides induced by extreme rainfall in Korean Mountain

    Science.gov (United States)

    Singh Pradhan, Ananta Man; Kang, Hyo-Sub; Kim, Yun-Tae

    2016-04-01

    This study uses a physically based approach to evaluate the factor of safety of the hillslope for different hydrological conditions, in Mt Umyeon, south of Seoul. The hydrological conditions were determined using intensity and duration of whole Korea of known landslide inventory data. Quantile regression statistical method was used to ascertain different probability warning levels on the basis of rainfall thresholds. Physically based models are easily interpreted and have high predictive capabilities but rely on spatially explicit and accurate parameterization, which is commonly not possible. Statistical probabilistic methods can include other causative factors which influence the slope stability such as forest, soil and geology, but rely on good landslide inventories of the site. In this study a hybrid approach has described that combines the physically-based landslide susceptibility for different hydrological conditions. A presence-only based maximum entropy model was used to hybrid and analyze relation of landslide with conditioning factors. About 80% of the landslides were listed among the unstable sites identified in the proposed model, thereby presenting its effectiveness and accuracy in determining unstable areas and areas that require evacuation. These cumulative rainfall thresholds provide a valuable reference to guide disaster prevention authorities in the issuance of warning levels with the ability to reduce losses and save lives.

  11. Study on a model of street vended food choices by Korean high school students.

    Science.gov (United States)

    Cho, Kiwoong; Park, Sanghyun; Joo, Nami

    2011-10-01

    Street vended food (SVF) includes food and beverages prepared and sold outdoors or in public areas by street merchants for consumption on the scene or later without further preparation. Due to its low price and convenience, SVF has been popular in Korea for a long time, particularly with high school students. Beyond Korea, SVF is also popular in southeast Asia and southern Africa in the form of ready-to-eat food. This study on high school students, who are main consumers of SVF in Korea, focused on the factors that affect consumer loyalty. The study was performed by questionnaire and used AMOS software to develop a structural equation model. The results of verifying the model's fidelity were χ(2) = 685.989, df = 261, GFI = 0.851, AGFI = 0.814, NFI = 0.901, CFI = 0.907, RMR = 0.048, indicating a satisfying structural model. SVF quality and service, emotional response, and the physical environment had a statistically significant effect on consumer loyalty. In contrast, SVF sanitation had no statistically significant effect on consumer loyalty. Based on these results, the sanitary management of SVF needs to be addressed immediately combined with education for SVF providers to maintain a clean environment.

  12. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  13. Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code.

    Science.gov (United States)

    Yoriyaz, H; dos Santos, A; Stabin, M G; Cabezas, R

    2000-07-01

    A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.

  14. A generalization of voxel-wise procedures for highdimensional statistical inference using ridge regression

    DEFF Research Database (Denmark)

    Sjöstrand, Karl; Cardenas, Valerie A.; Larsen, Rasmus

    2008-01-01

    regression to address this issue, allowing for a gradual introduction of correlation information into the model. We make the connections between ridge regression and voxel-wise procedures explicit and discuss relations to other statistical methods. Results are given on an in-vivo data set of deformation......Whole-brain morphometry denotes a group of methods with the aim of relating clinical and cognitive measurements to regions of the brain. Typically, such methods require the statistical analysis of a data set with many variables (voxels and exogenous variables) paired with few observations (subjects...

  15. Estimation of occupational and nonoccupational nitrogen dioxide exposure for Korean taxi drivers using a microenvironmental model

    International Nuclear Information System (INIS)

    Son, Busoon; Yang, Wonho; Breysse, Patrick; Chung, Taewoong; Lee, Youngshin

    2004-01-01

    Occupational and nonoccupational personal nitrogen dioxide (NO 2 ) exposures were measured using passive samplers for 31 taxi drivers in Asan and Chunan, Korea. Exposures were also estimated using a microenvironmental time-weighted average model based on indoor, outdoor and inside the taxi area measurements. Mean NO 2 indoor and outdoor concentrations inside and outside the taxi drivers' houses were 24.7±10.7 and 23.3±8.3 ppb, respectively, with a mean indoor to outdoor NO 2 ratio of 1.1. Mean personal NO 2 exposure of taxi drivers was 30.3±9.7 ppb. Personal NO 2 exposures for drivers were more strongly correlated with interior vehicle NO 2 levels (r=0.89) rather than indoor residential NO 2 levels (r=0.74) or outdoor NO 2 levels (r=0.71). The main source of NO 2 exposure for taxi drivers was considered to be occupational driving. Interestingly, the NO 2 exposures for drivers' using LPG-fueled vehicles (26.3±1.3 ppb) were significantly lower than those (38.1±1.3 ppb) using diesel-fueled vehicle (P 2 exposure with indoor and outdoor NO 2 levels of the residence, and interior vehicle NO 2 levels (P 2 levels because they drive diesel-using vehicles outdoors in Korea

  16. Sensitivity analysis of a dynamic food chain model DYNACON considering Korean agricultural conditions

    International Nuclear Information System (INIS)

    Hwang, W.T.; Lee, G.C.; Suh, K.S.; Kim, E.H.; Choi, Y.G.; Han, M.H.; Cho, G.S.

    2000-01-01

    The sensitivity analysis of input parameters for a dynamic food chain model DYNACON was performed as a function of deposition time for the long-lived radionuclides ( 137 Cs, 90 Sr) and the selected foodstuffs (cereals, milk). The influence of input parameters for short and long-term contaminations of the foodstuffs after a deposition was also investigated. The input parameters were sampled using a Latin hypercube sampling (LHS) technique, and their sensitivity indices were quantified as partial rank correlation coefficient (PRCC). PRCCs were strongly dependent on the contamination period of foodstuffs as well as the deposition time of radionuclides. In case of deposition during growing stage of agricultural plants, the input parameters associated with contamination by foliar absorption were relatively influential in long-term contamination as well as short-term contamination. They were also influential in short-term contamination in case of deposition during non-growing stage. As the contamination period is longer, the influence of parameters associated with contamination by root uptake was increased. This phenomenon was more remarkable in case of the deposition during non-growing stage than growing stage, and in case of 90 Sr deposition than 137 Cs deposition. In case of deposition during growing stage of pasture, the characteristic parameters of cattle such as feed-milk transfer factor and daily intake rate were relatively influential in the contamination of milk. (author)

  17. Two-tensor streamline tractography through white matter intra-voxel fiber crossings

    DEFF Research Database (Denmark)

    Qazi, Arish Asif; Kindlmann, G; O'Donnell, L

    2008-01-01

    An inherent drawback of the traditional diffusion tensor model is its limited ability to provide detailed information about multidirectional fiber architecture within a voxel. This leads to erroneous fiber tractography results in locations where fiber bundles cross each other. In this paper, we p...

  18. New hybrid voxelized/analytical primitive in Monte Carlo simulations for medical applications

    International Nuclear Information System (INIS)

    Bert, Julien; Lemaréchal, Yannick; Visvikis, Dimitris

    2016-01-01

    Monte Carlo simulations (MCS) applied in particle physics play a key role in medical imaging and particle therapy. In such simulations, particles are transported through voxelized phantoms derived from predominantly patient CT images. However, such voxelized object representation limits the incorporation of fine elements, such as artificial implants from CAD modeling or anatomical and functional details extracted from other imaging modalities. In this work we propose a new hYbrid Voxelized/ANalytical primitive (YVAN) that combines both voxelized and analytical object descriptions within the same MCS, without the need to simultaneously run two parallel simulations, which is the current gold standard methodology. Given that YVAN is simply a new primitive object, it does not require any modifications on the underlying MC navigation code. The new proposed primitive was assessed through a first simple MCS. Results from the YVAN primitive were compared against an MCS using a pure analytical geometry and the layer mass geometry concept. A perfect agreement was found between these simulations, leading to the conclusion that the new hybrid primitive is able to accurately and efficiently handle phantoms defined by a mixture of voxelized and analytical objects. In addition, two application-based evaluation studies in coronary angiography and intra-operative radiotherapy showed that the use of YVAN was 6.5% and 12.2% faster than the layered mass geometry method, respectively, without any associated loss of accuracy. However, the simplification advantages and differences in computational time improvements obtained with YVAN depend on the relative proportion of the analytical and voxelized structures used in the simulation as well as the size and number of triangles used in the description of the analytical object meshes. (paper)

  19. New hybrid voxelized/analytical primitive in Monte Carlo simulations for medical applications.

    Science.gov (United States)

    Bert, Julien; Lemaréchal, Yannick; Visvikis, Dimitris

    2016-05-07

    Monte Carlo simulations (MCS) applied in particle physics play a key role in medical imaging and particle therapy. In such simulations, particles are transported through voxelized phantoms derived from predominantly patient CT images. However, such voxelized object representation limits the incorporation of fine elements, such as artificial implants from CAD modeling or anatomical and functional details extracted from other imaging modalities. In this work we propose a new hYbrid Voxelized/ANalytical primitive (YVAN) that combines both voxelized and analytical object descriptions within the same MCS, without the need to simultaneously run two parallel simulations, which is the current gold standard methodology. Given that YVAN is simply a new primitive object, it does not require any modifications on the underlying MC navigation code. The new proposed primitive was assessed through a first simple MCS. Results from the YVAN primitive were compared against an MCS using a pure analytical geometry and the layer mass geometry concept. A perfect agreement was found between these simulations, leading to the conclusion that the new hybrid primitive is able to accurately and efficiently handle phantoms defined by a mixture of voxelized and analytical objects. In addition, two application-based evaluation studies in coronary angiography and intra-operative radiotherapy showed that the use of YVAN was 6.5% and 12.2% faster than the layered mass geometry method, respectively, without any associated loss of accuracy. However, the simplification advantages and differences in computational time improvements obtained with YVAN depend on the relative proportion of the analytical and voxelized structures used in the simulation as well as the size and number of triangles used in the description of the analytical object meshes.

  20. Clinical and Biochemical Profiles according to Homeostasis Model Assessment-insulin Resistance (HOMA-IR) in Korean Women with Polycystic Ovary Syndrome.

    Science.gov (United States)

    Lee, Da Eun; Park, Soo Yeon; Park, So Yun; Lee, Sa Ra; Chung, Hye Won; Jeong, Kyungah

    2014-12-01

    The aim of this study was to investigate the clinical and biochemical profiles according to homeostasis model assessment of insulin resistance (HOMA-IR) in Korean polycystic ovary syndrome (PCOS) patients. In 458 PCOS patients diagnosed by the Rotterdam European Society for Human Reproduction and Embryology (ESHRE) criteria, measurements of somatometry, blood test of hormones, glucose metabolic and lipid profiles, and transvaginal or transrectal ultrasonogram were carried out. HOMA-IR was then calculated and compared with the clinical and biochemical profiles related to PCOS. The patients were divided into 4 groups by quartiles of HOMA-IR. The mean level of HOMA-IR was 2.18 ± 1.73. Among the four groups separated according to HOMA-IR, body weight, body mass index (BMI), waist-to-hip ratio (WHR), triglyceride (TG), total cholesterol, high-density lipoprotein (HDL) cholesterol, low-density lipoprotein (LDL) cholesterol, lipid accumulation product (LAP) index, high-sensitivity C-reactive protein (hs-CRP), Apoprotein B, free testosterone, and sex hormone binding globulin (SHBG) were found to be significantly different. TG, LAP index, glucose metabolic profiles, and hs-CRP were positively correlated with HOMA-IR after adjustment for BMI. Our results suggest that the clinical and biochemical profiles which are applicable as cardiovascular risk factors are highly correlated with HOMA-IR in Korean women with PCOS.

  1. Creation of a voxel phantom of the ICRP reference crab.

    Science.gov (United States)

    Caffrey, E A; Higley, K A

    2013-06-01

    The International Commission on Radiological Protection (ICRP) has modeled twelve reference animal and plant (RAP) species using simple geometric shapes in Monte-Carlo (MCNP) based simulations. The focus has now shifted to creating voxel phantoms of each RAP in order to estimate doses to biota with a higher degree of confidence. This paper describes the creation of a voxel model of a Dungeness crab from CT images with shell, gills, gonads, hepatopancreas, and heart identified and segmented. Absorbed fractions were tabulated for each organ as a source and target at twelve photon and nine electron energies: 0.01, 0.015, 0.02, 0.03, 0.05, 0.1, 0.2, 0.5, 1.0, 1.5, 2.0, and 4.0 MeV for photons and 0.1, 0.2, 0.4, 0.5, 0.7, 1.0, 1.5, 2.0 and 4.0 MeV for electrons. AFs whose error exceeded 5% are marked with an underline in the data tables; AFs whose error was higher than 10% were excluded, and are shown in the tabulated data as a dashed line. A representative sample of the data is shown in Figs. 3-8; the entire data set is available as an electronic appendix. The results are consistent with previous small organism studies (Kinase, 2008; Stabin et al., 2006), and suggest that AF values are highly dependent on source organ location and mass. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Finding significantly connected voxels based on histograms of connection strengths

    DEFF Research Database (Denmark)

    Kasenburg, Niklas; Pedersen, Morten Vester; Darkner, Sune

    2016-01-01

    We explore a new approach for structural connectivity based segmentations of subcortical brain regions. Connectivity based segmentations are usually based on fibre connections from a seed region to predefined target regions. We present a method for finding significantly connected voxels based...... on the distribution of connection strengths. Paths from seed voxels to all voxels in a target region are obtained from a shortest-path tractography. For each seed voxel we approximate the distribution with a histogram of path scores. We hypothesise that the majority of estimated connections are false-positives...... and that their connection strength is distributed differently from true-positive connections. Therefore, an empirical null-distribution is defined for each target region as the average normalized histogram over all voxels in the seed region. Single histograms are then tested against the corresponding null...

  3. Organizational factors in Korean NPPs

    International Nuclear Information System (INIS)

    Jang, D. J.; Kim, Y. I.; Jeong, C. H.; Kim, J. W.

    2003-01-01

    Organizational factors are referred to as the factors that influence the achievement of a goal of an organization. Latent problems of an organization could contribute to causing human errors in such stages as design, operation and maintenance, and furthermore, leading to an severe accident. In order to evaluate an organization from the safety viewpoint, it is necessary to identify the organizational factors in a systematic fashion. In this paper, some efforts to identify the organizational factors in Korean NPPs are presented. The study was performed in the following steps: 1) Reviewing the definitions and range of the organizational factors used by the previous 13 researches, 2) Structuring the organizational factors by screening and collating factors, 3) Analysing the organizational factors that is considered to have contributed to the trip events based on the trip report of Korean NPPs, 4) Suggesting a more reliable taxonomy of organizational factors for event analysis by applying the Onion Structure Model to the selected factors

  4. North Korean nuclear negotiation drama

    International Nuclear Information System (INIS)

    Kim, Jai Bok

    1995-06-01

    This book reports negotiation on North Korean nuclear among South Korea, North Korea and U. S. It includes an account about international issues on North Korean nuclear activities, a new aspect on the problems of North Korean nuclear, pressure on North Korea and startup for dialogue trying to solve problems by communication, investigation by IAEA, IAEA resolution and high tension on Korean peninsula with North Korean nuclear.

  5. North Korean nuclear negotiation drama

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Bok

    1995-06-15

    This book reports negotiation on North Korean nuclear among South Korea, North Korea and U. S. It includes an account about international issues on North Korean nuclear activities, a new aspect on the problems of North Korean nuclear, pressure on North Korea and startup for dialogue trying to solve problems by communication, investigation by IAEA, IAEA resolution and high tension on Korean peninsula with North Korean nuclear.

  6. Cultural Validation of the Maslach Burnout Inventory for Korean Students

    Science.gov (United States)

    Shin, Hyojung; Puig, Ana; Lee, Jayoung; Lee, Ji Hee; Lee, Sang Min

    2011-01-01

    The purpose of this study was to examine the factorial validity of the MBI-SS in Korean students. Specifically, we investigated whether the original three-factor structure of the MBI-SS was appropriate for use with Korean students. In addition, by running multi-group structural equation model analyses with factorial invariance tests simultaneously…

  7. Korean Screen Cultures

    DEFF Research Database (Denmark)

    Screen Cultures sets out to redress this imbalance with a broad selection of essays spanning both North and South as well as different methodological approaches, from ethnographic and audience studies to cultural materialist readings. The first section of the book, «The South», highlights popular media...... new approaches to Korean popular culture beyond national borders and includes work on K-pop and Korean television drama. This book is a vital addition to existing scholarship on Korean popular culture, offering a unique view by providing an imaginary unification of the two Koreas negotiated through...

  8. Models for Estimating Genetic Parameters of Milk Production Traits Using Random Regression Models in Korean Holstein Cattle

    Directory of Open Access Journals (Sweden)

    C. I. Cho

    2016-05-01

    Full Text Available The objectives of the study were to estimate genetic parameters for milk production traits of Holstein cattle using random regression models (RRMs, and to compare the goodness of fit of various RRMs with homogeneous and heterogeneous residual variances. A total of 126,980 test-day milk production records of the first parity Holstein cows between 2007 and 2014 from the Dairy Cattle Improvement Center of National Agricultural Cooperative Federation in South Korea were used. These records included milk yield (MILK, fat yield (FAT, protein yield (PROT, and solids-not-fat yield (SNF. The statistical models included random effects of genetic and permanent environments using Legendre polynomials (LP of the third to fifth order (L3–L5, fixed effects of herd-test day, year-season at calving, and a fixed regression for the test-day record (third to fifth order. The residual variances in the models were either homogeneous (HOM or heterogeneous (15 classes, HET15; 60 classes, HET60. A total of nine models (3 orders of polynomials×3 types of residual variance including L3-HOM, L3-HET15, L3-HET60, L4-HOM, L4-HET15, L4-HET60, L5-HOM, L5-HET15, and L5-HET60 were compared using Akaike information criteria (AIC and/or Schwarz Bayesian information criteria (BIC statistics to identify the model(s of best fit for their respective traits. The lowest BIC value was observed for the models L5-HET15 (MILK; PROT; SNF and L4-HET15 (FAT, which fit the best. In general, the BIC values of HET15 models for a particular polynomial order was lower than that of the HET60 model in most cases. This implies that the orders of LP and types of residual variances affect the goodness of models. Also, the heterogeneity of residual variances should be considered for the test-day analysis. The heritability estimates of from the best fitted models ranged from 0.08 to 0.15 for MILK, 0.06 to 0.14 for FAT, 0.08 to 0.12 for PROT, and 0.07 to 0.13 for SNF according to days in milk of first

  9. Understanding Korean food culture from Korean paintings

    Directory of Open Access Journals (Sweden)

    Hae Kyung Chung

    2016-03-01

    Conclusion: Beyond the basic value of food in maximizing nutrients and energy, Korean food culture has developed distinctive cultural characteristics through more than 5,000 years of agricultural history. Although the genre paintings analyzed in this paper are limited to a certain era, this paper will serve as a milestone in providing direction for future studies.

  10. Deconstructing Kimilsungism: A Political and Ideological Analysis of the North Korean Regime

    OpenAIRE

    Sangiovanni, John James

    2009-01-01

    This thesis argues that the North Korean model of government is a unique model that is influenced, to varying degrees, by extreme leftist and rightist doctrines, including Marxism-Leninism, Stalinism, Maoism, fascism, and Nazism; and shares at least some similarities with all these established models. Rather than being a mere political model, the North Korean model is a political religion that incorporates traits of each of the above-noted models with Korean mythology, Confucianism, extreme ...

  11. Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments

    International Nuclear Information System (INIS)

    Bottigli, U.; Brunetti, A.; Golosio, B.; Oliva, P.; Stumbo, S.; Vincze, L.; Randaccio, P.; Bleuet, P.; Simionovici, A.; Somogyi, A.

    2004-01-01

    A Monte Carlo code for the simulation of X-ray imaging and spectroscopy experiments in heterogeneous samples is presented. The energy spectrum, polarization and profile of the incident beam can be defined so that X-ray tube systems as well as synchrotron sources can be simulated. The sample is modeled as a 3D regular grid. The chemical composition and density is given at each point of the grid. Photoelectric absorption, fluorescent emission, elastic and inelastic scattering are included in the simulation. The core of the simulation is a fast routine for the calculation of the path lengths of the photon trajectory intersections with the grid voxels. The voxel representation is particularly useful for samples that cannot be well described by a small set of polyhedra. This is the case of most naturally occurring samples. In such cases, voxel-based simulations are much less expensive in terms of computational cost than simulations on a polygonal representation. The efficient scheme used for calculating the path lengths in the voxels and the use of variance reduction techniques make the code suitable for the detailed simulation of complex experiments on generic samples in a relatively short time. Examples of applications to X-ray imaging and spectroscopy experiments are discussed

  12. Voxel-Based Neighborhood for Spatial Shape Pattern Classification of Lidar Point Clouds with Supervised Learning

    Directory of Open Access Journals (Sweden)

    Victoria Plaza-Leiva

    2017-03-01

    Full Text Available Improving the effectiveness of spatial shape features classification from 3D lidar data is very relevant because it is largely used as a fundamental step towards higher level scene understanding challenges of autonomous vehicles and terrestrial robots. In this sense, computing neighborhood for points in dense scans becomes a costly process for both training and classification. This paper proposes a new general framework for implementing and comparing different supervised learning classifiers with a simple voxel-based neighborhood computation where points in each non-overlapping voxel in a regular grid are assigned to the same class by considering features within a support region defined by the voxel itself. The contribution provides offline training and online classification procedures as well as five alternative feature vector definitions based on principal component analysis for scatter, tubular and planar shapes. Moreover, the feasibility of this approach is evaluated by implementing a neural network (NN method previously proposed by the authors as well as three other supervised learning classifiers found in scene processing methods: support vector machines (SVM, Gaussian processes (GP, and Gaussian mixture models (GMM. A comparative performance analysis is presented using real point clouds from both natural and urban environments and two different 3D rangefinders (a tilting Hokuyo UTM-30LX and a Riegl. Classification performance metrics and processing time measurements confirm the benefits of the NN classifier and the feasibility of voxel-based neighborhood.

  13. Voxel-Based Neighborhood for Spatial Shape Pattern Classification of Lidar Point Clouds with Supervised Learning.

    Science.gov (United States)

    Plaza-Leiva, Victoria; Gomez-Ruiz, Jose Antonio; Mandow, Anthony; García-Cerezo, Alfonso

    2017-03-15

    Improving the effectiveness of spatial shape features classification from 3D lidar data is very relevant because it is largely used as a fundamental step towards higher level scene understanding challenges of autonomous vehicles and terrestrial robots. In this sense, computing neighborhood for points in dense scans becomes a costly process for both training and classification. This paper proposes a new general framework for implementing and comparing different supervised learning classifiers with a simple voxel-based neighborhood computation where points in each non-overlapping voxel in a regular grid are assigned to the same class by considering features within a support region defined by the voxel itself. The contribution provides offline training and online classification procedures as well as five alternative feature vector definitions based on principal component analysis for scatter, tubular and planar shapes. Moreover, the feasibility of this approach is evaluated by implementing a neural network (NN) method previously proposed by the authors as well as three other supervised learning classifiers found in scene processing methods: support vector machines (SVM), Gaussian processes (GP), and Gaussian mixture models (GMM). A comparative performance analysis is presented using real point clouds from both natural and urban environments and two different 3D rangefinders (a tilting Hokuyo UTM-30LX and a Riegl). Classification performance metrics and processing time measurements confirm the benefits of the NN classifier and the feasibility of voxel-based neighborhood.

  14. Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bottigli, U. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Sezione INFN di Cagliari (Italy); Brunetti, A. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Golosio, B. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy) and Sezione INFN di Cagliari (Italy)]. E-mail: golosio@uniss.it; Oliva, P. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Stumbo, S. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Vincze, L. [Department of Chemistry, University of Antwerp (Belgium); Randaccio, P. [Dipartimento di Fisica dell' Universita di Cagliari and Sezione INFN di Cagliari (Italy); Bleuet, P. [European Synchrotron Radiation Facility, Grenoble (France); Simionovici, A. [European Synchrotron Radiation Facility, Grenoble (France); Somogyi, A. [European Synchrotron Radiation Facility, Grenoble (France)

    2004-10-08

    A Monte Carlo code for the simulation of X-ray imaging and spectroscopy experiments in heterogeneous samples is presented. The energy spectrum, polarization and profile of the incident beam can be defined so that X-ray tube systems as well as synchrotron sources can be simulated. The sample is modeled as a 3D regular grid. The chemical composition and density is given at each point of the grid. Photoelectric absorption, fluorescent emission, elastic and inelastic scattering are included in the simulation. The core of the simulation is a fast routine for the calculation of the path lengths of the photon trajectory intersections with the grid voxels. The voxel representation is particularly useful for samples that cannot be well described by a small set of polyhedra. This is the case of most naturally occurring samples. In such cases, voxel-based simulations are much less expensive in terms of computational cost than simulations on a polygonal representation. The efficient scheme used for calculating the path lengths in the voxels and the use of variance reduction techniques make the code suitable for the detailed simulation of complex experiments on generic samples in a relatively short time. Examples of applications to X-ray imaging and spectroscopy experiments are discussed.

  15. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Niboyet, Jean; Mundler, Olivier

    2007-01-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  16. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)]. E-mail: eric.guedj@ap-hm.fr; Taieb, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Cammilleri, Serge [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Lussato, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Laforte, Catherine de [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Niboyet, Jean [Unite d' Etude et de Traitement de la Douleur, Clinique La Phoceanne, Marseille (France); Mundler, Olivier [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)

    2007-02-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  17. Korean Affairs Report

    Science.gov (United States)

    1985-09-20

    Pyongyang station, the South Korean delegation boarded 16 Mercedes Benz sedans and seven buses, then headed for the Koryo Hotel. The South Korean...money-making, loudly advertising "relief of hungry children, "relief of the destitute" and "programme for the rebirth of narcotic addicts. It was with... market are twin pains these days. When they convert what they earned on the bearish stock exchange into dol- lars, their returns show minus gains

  18. On Being There: Korean in Japan.

    Science.gov (United States)

    Maher, John C.; Kawanishi, Yumiko

    1995-01-01

    Examines the experiences of ethnic Koreans and the Korean language in Japan since 1945, focusing on Japanese attitudes toward Koreans and the Korean language, provisions for Korean and bilingual education, and the increasing influence of Koreans in Japanese society. (18 references) (MDM)

  19. Voxel-based morphometry and voxel-based diffusion tensor analysis in amyotrophic lateral sclerosis

    International Nuclear Information System (INIS)

    Chen Zhiye; Ma Lin; Lou Xin; Wang Yan

    2010-01-01

    Objective: To evaluate gray matter volume, white matter volume and FA value changes in amyatrophic lateral sclerosis (ALS) patients by voxel-based morphometry (VBM) and voxel-based diffusion tensor analysis (VBDTA). Methods: Thirty-nine definite or probable ALS patients diagnosed by El Escorial standard and 39 healthy controls were recruited and underwent conventional MR scans and the neuropsychological evaluation. The 3D FSPGR T 1 WI and DTI data were collected on GE Medical 3.0 T MRI system. The 3DT 1 structural images were normalized, segmented and smoothed, and then VBM analysis was performed. DTI data were acquired from 76 healthy controls, and FA map template was made. FA maps generated from the DTI data of ALS patients and healthy controls were normalized to the FA map template for voxel-based analysis. ANCOVA was applied, controlling with age and total intracranial volume for VBM and age for VBDDTA. A statistical threshold of P<0.01 (uncorrected) and cluster level of more than continuous 20 voxels determined significance. Results: Statistical results showed no significant difference in the global volumes of gray matter and white matter, total intracranial volumes and gray matter fraction between ALS patients and healthy controls, but the white matter fraction of ALS patients (0.29 ± 0.02) was significantly less than that of healthy controls (0.30 ± 0.02) statistically (P=0.003). There was significant reduction of gray matter volumes in bilateral superior frontal gyri and precentral gyri, right middle frontal gyrus, right middle and inferior temporal gyrus, left superior occipital gyrus and cuneus and left insula in ALS patients when compared with healthy controls; and the regional reduction of white matter volumes in ALS patients mainly located in genu of corpus callosum, bilateral medial frontal gyri, paracentral lobule and insula, right superior and middle frontal gyrus and left postcentral gyrus. VBDTA showed decrease in FA values in bilateral

  20. Voxel-wise prostate cell density prediction using multiparametric magnetic resonance imaging and machine learning.

    Science.gov (United States)

    Sun, Yu; Reynolds, Hayley M; Wraith, Darren; Williams, Scott; Finnegan, Mary E; Mitchell, Catherine; Murphy, Declan; Haworth, Annette

    2018-04-26

    There are currently no methods to estimate cell density in the prostate. This study aimed to develop predictive models to estimate prostate cell density from multiparametric magnetic resonance imaging (mpMRI) data at a voxel level using machine learning techniques. In vivo mpMRI data were collected from 30 patients before radical prostatectomy. Sequences included T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced imaging. Ground truth cell density maps were computed from histology and co-registered with mpMRI. Feature extraction and selection were performed on mpMRI data. Final models were fitted using three regression algorithms including multivariate adaptive regression spline (MARS), polynomial regression (PR) and generalised additive model (GAM). Model parameters were optimised using leave-one-out cross-validation on the training data and model performance was evaluated on test data using root mean square error (RMSE) measurements. Predictive models to estimate voxel-wise prostate cell density were successfully trained and tested using the three algorithms. The best model (GAM) achieved a RMSE of 1.06 (± 0.06) × 10 3 cells/mm 2 and a relative deviation of 13.3 ± 0.8%. Prostate cell density can be quantitatively estimated non-invasively from mpMRI data using high-quality co-registered data at a voxel level. These cell density predictions could be used for tissue classification, treatment response evaluation and personalised radiotherapy.

  1. The Best Prediction Model for Trauma Outcomes of the Current Korean Population: a Comparative Study of Three Injury Severity Scoring Systems

    Directory of Open Access Journals (Sweden)

    Kyoungwon Jung

    2016-08-01

    Full Text Available Background: Injury severity scoring systems that quantify and predict trauma outcomes have not been established in Korea. This study was designed to determine the best system for use in the Korean trauma population. Methods: We collected and analyzed the data from trauma patients admitted to our institution from January 2010 to December 2014. Injury Severity Score (ISS, Revised Trauma Score (RTS, and Trauma and Injury Severity Score (TRISS were calculated based on the data from the enrolled patients. Area under the receiver operating characteristic (ROC curve (AUC for the prediction ability of each scoring system was obtained, and a pairwise comparison of ROC curves was performed. Additionally, the cut-off values were estimated to predict mortality, and the corresponding accuracy, positive predictive value, and negative predictive value were obtained. Results: A total of 7,120 trauma patients (6,668 blunt and 452 penetrating injuries were enrolled in this study. The AUCs of ISS, RTS, and TRISS were 0.866, 0.894, and 0.942, respectively, and the prediction ability of the TRISS was significantly better than the others (p < 0.001, respectively. The cut-off value of the TRISS was 0.9082, with a sensitivity of 81.9% and specificity of 92.0%; mortality was predicted with an accuracy of 91.2%; its positive predictive value was the highest at 46.8%. Conclusions: The results of our study were based on the data from one institution and suggest that the TRISS is the best prediction model of trauma outcomes in the current Korean population. Further study is needed with more data from multiple centers in Korea.

  2. Chinese reference human voxel phantoms for radiation protection: development, application and recent progress

    International Nuclear Information System (INIS)

    Pan Yuxi; Qiu Rui; Ren Li; Zhu Huanjun; Li Junli; Liu Liye

    2014-01-01

    This paper presents the work of constructing Chinese reference human voxel phantoms, taking Chinese reference adult female voxel model for example. In this study, a site-specific skeleton structure was built, some radiation sensitive organs were supplemented. Organ sub-segmentation was taken into account. The constructed phantoms include almost all radiation sensitive organs required by ICRP new recommendation. Masses of the organs are almost consistent with the Chinese reference data within 5%. The Chinese reference human phantoms have been applied both in internal dosimetry and external dosimetry. The results provide fundamental data for Chinese radiation dosimetry. In addition, the newly established detailed breast model and micro-bone model were introduced. (authors)

  3. Chemical data assimilation of geostationary aerosol optical depth and PM surface observations on regional aerosol modeling over the Korean Peninsula during KORUS-AQ campaign

    Science.gov (United States)

    Jung, J.; Choi, Y.; Souri, A.; Jeon, W.

    2017-12-01

    Particle matter(PM) has played a significantly deleterious role in affecting human health and climate. Recently, continuous high concentrations of PM in Korea attracted public attention to this critical issue, and the Korea-United States Air Quality Study(KORUS-AQ) campaign in 2016 was conducted to investigate the causes. For this study, we adjusted the initial conditions in the chemical transport model(CTM) to improve its performance over Korean Peninsula during KORUS-AQ period, using the campaign data to evaluate our model performance. We used the Optimal Interpolation(OI) approach and used hourly surface air quality measurement data from the Air Quality Monitoring Station(AQMS) by NIER and the aerosol optical depth(AOD) measured by a GOCI sensor from the geostationary orbit onboard the Communication Ocean and Meteorological Satellite(COMS). The AOD at 550nm has a 6km spatial resolution and broad coverage over East Asia. After assimilating the surface air quality observation data, the model accuracy significantly improved compared to base model result (without assimilation). It reported very high correlation value (0.98) and considerably decreased mean bias. Especially, it well captured some high peaks which was underpredicted by the base model. To assimilate satellite data, we applied AOD scaling factors to quantify each specie's contribution to total PM concentration and find-mode fraction(FMF) to define vertical distribution. Finally, the improvement showed fairly good agreement.

  4. Korean War Veterans by State

    Data.gov (United States)

    Department of Veterans Affairs — The spreadsheet of Korean War Veterans by State includes the total Korean War Veteran population for each state and broken out by age and gender. It also includes...

  5. Laser-induced forward transfer (LIFT) of congruent voxels

    Energy Technology Data Exchange (ETDEWEB)

    Piqué, Alberto, E-mail: pique@nrl.navy.mil [Materials Science and Technology Division, Code 6364, Naval Research Laboratory, Washington, DC 20375 (United States); Kim, Heungsoo; Auyeung, Raymond C.Y.; Beniam, Iyoel [Materials Science and Technology Division, Code 6364, Naval Research Laboratory, Washington, DC 20375 (United States); Breckenfeld, Eric [National Research Council Fellow at the Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-06-30

    Highlights: • Laser-induced forward transfer (LIFT) is demonstrated with high viscosity Ag nanopaste. • Under the right conditions (viscosity and fluence) the transfer of congruent voxels was achieved. • For viscosities under 100 Pa s, congruent voxel transfer of silver nano-suspensions is only possible under a very narrow range of conditions. • For viscosities over 100 Pa s, congruent voxel transfer of silver nano-pastes works over a wider range of fluences, donor substrate thickness, gap distances and voxel areas. • The laser transfer of congruent voxels can be used for printing electronic patterns in particular interconnects. - Abstract: Laser-induced forward transfer (LIFT) of functional materials offers unique advantages and capabilities for the rapid prototyping of electronic, optical and sensor elements. The use of LIFT for printing high viscosity metallic nano-inks and nano-pastes can be optimized for the transfer of voxels congruent with the shape of the laser pulse, forming thin film-like structures non-lithographically. These processes are capable of printing patterns with excellent lateral resolution and thickness uniformity typically found in 3-dimensional stacked assemblies, MEMS-like structures and free-standing interconnects. However, in order to achieve congruent voxel transfer with LIFT, the particle size and viscosity of the ink or paste suspensions must be adjusted to minimize variations due to wetting and drying effects. When LIFT is carried out with high-viscosity nano-suspensions, the printed voxel size and shape become controllable parameters, allowing the printing of thin-film like structures whose shape is determined by the spatial distribution of the laser pulse. The result is a new level of parallelization beyond current serial direct-write processes whereby the geometry of each printed voxel can be optimized according to the pattern design. This work shows how LIFT of congruent voxels can be applied to the fabrication of 2D

  6. Laser-induced forward transfer (LIFT) of congruent voxels

    International Nuclear Information System (INIS)

    Piqué, Alberto; Kim, Heungsoo; Auyeung, Raymond C.Y.; Beniam, Iyoel; Breckenfeld, Eric

    2016-01-01

    Highlights: • Laser-induced forward transfer (LIFT) is demonstrated with high viscosity Ag nanopaste. • Under the right conditions (viscosity and fluence) the transfer of congruent voxels was achieved. • For viscosities under 100 Pa s, congruent voxel transfer of silver nano-suspensions is only possible under a very narrow range of conditions. • For viscosities over 100 Pa s, congruent voxel transfer of silver nano-pastes works over a wider range of fluences, donor substrate thickness, gap distances and voxel areas. • The laser transfer of congruent voxels can be used for printing electronic patterns in particular interconnects. - Abstract: Laser-induced forward transfer (LIFT) of functional materials offers unique advantages and capabilities for the rapid prototyping of electronic, optical and sensor elements. The use of LIFT for printing high viscosity metallic nano-inks and nano-pastes can be optimized for the transfer of voxels congruent with the shape of the laser pulse, forming thin film-like structures non-lithographically. These processes are capable of printing patterns with excellent lateral resolution and thickness uniformity typically found in 3-dimensional stacked assemblies, MEMS-like structures and free-standing interconnects. However, in order to achieve congruent voxel transfer with LIFT, the particle size and viscosity of the ink or paste suspensions must be adjusted to minimize variations due to wetting and drying effects. When LIFT is carried out with high-viscosity nano-suspensions, the printed voxel size and shape become controllable parameters, allowing the printing of thin-film like structures whose shape is determined by the spatial distribution of the laser pulse. The result is a new level of parallelization beyond current serial direct-write processes whereby the geometry of each printed voxel can be optimized according to the pattern design. This work shows how LIFT of congruent voxels can be applied to the fabrication of 2D

  7. Efficient simulation of voxelized phantom in GATE with embedded SimSET multiple photon history generator

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Lin, Yi-Hsing; Ni, Yu-Ching; Wu, Jay; Jan, Meei-Ling

    2014-10-01

    GEANT4 Application for Tomographic Emission (GATE) is a powerful Monte Carlo simulator that combines the advantages of the general-purpose GEANT4 simulation code and the specific software tool implementations dedicated to emission tomography. However, the detailed physical modelling of GEANT4 is highly computationally demanding, especially when tracking particles through voxelized phantoms. To circumvent the relatively slow simulation of voxelized phantoms in GATE, another efficient Monte Carlo code can be used to simulate photon interactions and transport inside a voxelized phantom. The simulation system for emission tomography (SimSET), a dedicated Monte Carlo code for PET/SPECT systems, is well-known for its efficiency in simulation of voxel-based objects. An efficient Monte Carlo workflow integrating GATE and SimSET for simulating pinhole SPECT has been proposed to improve voxelized phantom simulation. Although the workflow achieves a desirable increase in speed, it sacrifices the ability to simulate decaying radioactive sources such as non-pure positron emitters or multiple emission isotopes with complex decay schemes and lacks the modelling of time-dependent processes due to the inherent limitations of the SimSET photon history generator (PHG). Moreover, a large volume of disk storage is needed to store the huge temporal photon history file produced by SimSET that must be transported to GATE. In this work, we developed a multiple photon emission history generator (MPHG) based on SimSET/PHG to support a majority of the medically important positron emitters. We incorporated the new generator codes inside GATE to improve the simulation efficiency of voxelized phantoms in GATE, while eliminating the need for the temporal photon history file. The validation of this new code based on a MicroPET R4 system was conducted for 124I and 18F with mouse-like and rat-like phantoms. Comparison of GATE/MPHG with GATE/GEANT4 indicated there is a slight difference in energy

  8. Quantitative Analysis on the Energy and Environmental Impact of the Korean National Energy R&D Roadmap a Using Bottom-Up Energy System Model

    Directory of Open Access Journals (Sweden)

    Sang Jin Choi

    2017-03-01

    Full Text Available According to the Paris Agreement at the 21st Conference of the Parties, 196 member states are obliged to submit their Intended Nationally Determined Contributions (INDC for every 5 years. As a member, South Korea has already proposed the reduction target and need to submit the achievement as a result of the policies and endeavors in the near future. In this paper, a Korean bottom-up energy system model to support the low-carbon national energy R&D roadmap will be introduced and through the modeling of various scenarios, the mid-to long-term impact on energy consumptions and CO2 emissions will be analyzed as well. The results of the analysis showed that, assuming R&D investments for the 11 types of technologies, savings of 13.7% with regards to final energy consumptions compared to the baseline scenario would be feasible by 2050. Furthermore, in the field of power generation, the generation proportion of new and renewable energy is expected to increase from 3.0% as of 2011 to 19.4% by 2050. This research also suggested that the analysis on the Energy Technology R&D Roadmap based on the model can be used not only for overall impact analysis and R&D portfolio establishment, but also for the development of detailed R&D strategies.

  9. Design and Methods of the Korean Organ Transplantation Registry

    Directory of Open Access Journals (Sweden)

    Jaeseok Yang, MD, PhD

    2017-08-01

    Conclusions. KOTRY, as a systematic Korean transplant cohort, is expected to provide important information on Asian organ transplantation. The processes used to establish KOTRY provide a good model for launching new nationwide transplant cohort studies.

  10. A South Korean perspective

    International Nuclear Information System (INIS)

    Lee, Seo-Hang

    1992-01-01

    Recognizing the recent changes in international environment security structures suited for specific situations should be conceived. In order to achieve the way to regional security in North-East Asia the outstanding issue left over from the cold war, divided Korean peninsula, and other subregional disputes have to be solved. In building confidence between the two countries the recently adopted security related accords ('The Agreement on Reconciliation, Non-aggression and Exchange and Cooperation between the South and the North' and the 'Joint declaration on the Denuclearization of the Korean peninsula') provide a framework for improvements of relations

  11. Comparison of NMR simulations of porous media derived from analytical and voxelized representations.

    Science.gov (United States)

    Jin, Guodong; Torres-Verdín, Carlos; Toumelin, Emmanuel

    2009-10-01

    We develop and compare two formulations of the random-walk method, grain-based and voxel-based, to simulate the nuclear-magnetic-resonance (NMR) response of fluids contained in various models of porous media. The grain-based approach uses a spherical grain pack as input, where the solid surface is analytically defined without an approximation. In the voxel-based approach, the input is a computer-tomography or computer-generated image of reconstructed porous media. Implementation of the two approaches is largely the same, except for the representation of porous media. For comparison, both approaches are applied to various analytical and digitized models of porous media: isolated spherical pore, simple cubic packing of spheres, and random packings of monodisperse and polydisperse spheres. We find that spin magnetization decays much faster in the digitized models than in their analytical counterparts. The difference in decay rate relates to the overestimation of surface area due to the discretization of the sample; it cannot be eliminated even if the voxel size decreases. However, once considering the effect of surface-area increase in the simulation of surface relaxation, good quantitative agreement is found between the two approaches. Different grain or pore shapes entail different rates of increase of surface area, whereupon we emphasize that the value of the "surface-area-corrected" coefficient may not be universal. Using an example of X-ray-CT image of Fontainebleau rock sample, we show that voxel size has a significant effect on the calculated surface area and, therefore, on the numerically simulated magnetization response.

  12. Sparse and Adaptive Diffusion Dictionary (SADD) for recovering intra-voxel white matter structure.

    Science.gov (United States)

    Aranda, Ramon; Ramirez-Manzanares, Alonso; Rivera, Mariano

    2015-12-01

    On the analysis of the Diffusion-Weighted Magnetic Resonance Images, multi-compartment models overcome the limitations of the well-known Diffusion Tensor model for fitting in vivo brain axonal orientations at voxels with fiber crossings, branching, kissing or bifurcations. Some successful multi-compartment methods are based on diffusion dictionaries. The diffusion dictionary-based methods assume that the observed Magnetic Resonance signal at each voxel is a linear combination of the fixed dictionary elements (dictionary atoms). The atoms are fixed along different orientations and diffusivity profiles. In this work, we present a sparse and adaptive diffusion dictionary method based on the Diffusion Basis Functions Model to estimate in vivo brain axonal fiber populations. Our proposal overcomes the following limitations of the diffusion dictionary-based methods: the limited angular resolution and the fixed shapes for the atom set. We propose to iteratively re-estimate the orientations and the diffusivity profile of the atoms independently at each voxel by using a simplified and easier-to-solve mathematical approach. As a result, we improve the fitting of the Diffusion-Weighted Magnetic Resonance signal. The advantages with respect to the former Diffusion Basis Functions method are demonstrated on the synthetic data-set used on the 2012 HARDI Reconstruction Challenge and in vivo human data. We demonstrate that improvements obtained in the intra-voxel fiber structure estimations benefit brain research allowing to obtain better tractography estimations. Hence, these improvements result in an accurate computation of the brain connectivity patterns. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The host immune enhancing agent Korean red ginseng oil successfully attenuates Brucella abortus infection in a murine model.

    Science.gov (United States)

    Reyes, Alisha Wehdnesday Bernardo; Hop, Huynh Tan; Arayan, Lauren Togonon; Huy, Tran Xuan Ngoc; Park, Soo Jong; Kim, Kwang Dong; Min, WonGi; Lee, Hu Jang; Rhee, Man Hee; Kwak, Yi-Seong; Kim, Suk

    2017-02-23

    Panax ginseng Meyer (Araliaceae), is one of the most valuable traditional Chinese medicines and is used for the treatment of various human diseases. In this study, we elucidated the protective mechanism of the essential oil from Korean red ginseng (RGO) against Brucella infection. The effects of RGO on Brucella abortus viability, NO production, uptake and intracellular growth in macrophages were investigated. Mice were intraperitoneally infected with B. abortus and orally treated with RGO for 14 days. The weights and bacterial numbers from each spleen were monitored, and the sera were evaluated for cytokine production. B. abortus viability was not affected, whereas NO production, internalization and intracellular replication were inhibited in RGO-treated macrophages. Bacterial adherence, F-actin polymerization and MAPK signaling protein phosphorylation (ERK1/2, JNK and p38α) were reduced and the co-localization of B. abortus-containing phagosomes with LAMP-1 was augmented in RGO-treated cells compared to untreated cells. RGO displayed protective effects against cell damage by inhibiting nitrite production during B. abortus infection in macrophages. Moreover, the spleen weight and bacterial burden were lower in the RGO-treated group than in the control group. The uninfected RGO-treated mice displayed increased TNF-α and IFN-γ production, whereas the B. abortus-infected RGO-treated mice showed reduced IL-10 production compared to the control. RGO exhibits protective effects against B. abortus infection in vitro and in vivo, which emphasize the beneficial effects of RGO in the prevention and treatment of brucellosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Chord-based versus voxel-based methods of electron transport in the skeletal tissues

    International Nuclear Information System (INIS)

    Shah, Amish P.; Jokisch, Derek W.; Rajon, Didier A.; Watchman, Christopher J.; Patton, Phillip W.; Bolch, Wesley E.

    2005-01-01

    Anatomic models needed for internal dose assessment have traditionally been developed using mathematical surface equations to define organ boundaries, shapes, and their positions within the body. Many researchers, however, are now advocating the use of tomographic models created from segmented patient computed tomography (CT) or magnetic resonance (MR) scans. In the skeleton, however, the tissue structures of the bone trabeculae, marrow cavities, and endosteal layer are exceedingly small and of complex shape, and thus do not lend themselves easily to either stylistic representations or in-vivo CT imaging. Historically, the problem of modeling the skeletal tissues has been addressed through the development of chord-based methods of radiation particle transport, as given by studies at the University of Leeds (Leeds, UK) using a 44-year male subject. We have proposed an alternative approach to skeletal dosimetry in which excised sections of marrow-intact cadaver spongiosa are imaged directly via microCT scanning. The cadaver selected for initial investigation of this technique was a 66-year male subject of nominal body mass index (22.7 kg m -2 ). The objectives of the present study were to compare chord-based versus voxel-based methods of skeletal dosimetry using data from the UF 66-year male subject. Good agreement between chord-based and voxel-based transport was noted for marrow irradiation by either bone surface or bone volume sources up to 500-1000 keV (depending upon the skeletal site). In contrast, chord-based models of electron transport yielded consistently lower values of the self-absorbed fraction to marrow tissues than seen under voxel-based transport at energies above 100 keV, a feature directly attributed to the inability of chord-based models to account for nonlinear electron trajectories. Significant differences were also noted in the dosimetry of the endosteal layer (for all source tissues), with chord-based transport predicting a higher fraction of

  15. a Voxel-Based Filtering Algorithm for Mobile LIDAR Data

    Science.gov (United States)

    Qin, H.; Guan, G.; Yu, Y.; Zhong, L.

    2018-04-01

    This paper presents a stepwise voxel-based filtering algorithm for mobile LiDAR data. In the first step, to improve computational efficiency, mobile LiDAR points, in xy-plane, are first partitioned into a set of two-dimensional (2-D) blocks with a given block size, in each of which all laser points are further organized into an octree partition structure with a set of three-dimensional (3-D) voxels. Then, a voxel-based upward growing processing is performed to roughly separate terrain from non-terrain points with global and local terrain thresholds. In the second step, the extracted terrain points are refined by computing voxel curvatures. This voxel-based filtering algorithm is comprehensively discussed in the analyses of parameter sensitivity and overall performance. An experimental study performed on multiple point cloud samples, collected by different commercial mobile LiDAR systems, showed that the proposed algorithm provides a promising solution to terrain point extraction from mobile point clouds.

  16. Laser-induced forward transfer (LIFT) of congruent voxels

    Science.gov (United States)

    Piqué, Alberto; Kim, Heungsoo; Auyeung, Raymond C. Y.; Beniam, Iyoel; Breckenfeld, Eric

    2016-06-01

    Laser-induced forward transfer (LIFT) of functional materials offers unique advantages and capabilities for the rapid prototyping of electronic, optical and sensor elements. The use of LIFT for printing high viscosity metallic nano-inks and nano-pastes can be optimized for the transfer of voxels congruent with the shape of the laser pulse, forming thin film-like structures non-lithographically. These processes are capable of printing patterns with excellent lateral resolution and thickness uniformity typically found in 3-dimensional stacked assemblies, MEMS-like structures and free-standing interconnects. However, in order to achieve congruent voxel transfer with LIFT, the particle size and viscosity of the ink or paste suspensions must be adjusted to minimize variations due to wetting and drying effects. When LIFT is carried out with high-viscosity nano-suspensions, the printed voxel size and shape become controllable parameters, allowing the printing of thin-film like structures whose shape is determined by the spatial distribution of the laser pulse. The result is a new level of parallelization beyond current serial direct-write processes whereby the geometry of each printed voxel can be optimized according to the pattern design. This work shows how LIFT of congruent voxels can be applied to the fabrication of 2D and 3D microstructures by adjusting the viscosity of the nano-suspension and laser transfer parameters.

  17. Coarse Point Cloud Registration by Egi Matching of Voxel Clusters

    Science.gov (United States)

    Wang, Jinhu; Lindenbergh, Roderik; Shen, Yueqian; Menenti, Massimo

    2016-06-01

    Laser scanning samples the surface geometry of objects efficiently and records versatile information as point clouds. However, often more scans are required to fully cover a scene. Therefore, a registration step is required that transforms the different scans into a common coordinate system. The registration of point clouds is usually conducted in two steps, i.e. coarse registration followed by fine registration. In this study an automatic marker-free coarse registration method for pair-wise scans is presented. First the two input point clouds are re-sampled as voxels and dimensionality features of the voxels are determined by principal component analysis (PCA). Then voxel cells with the same dimensionality are clustered. Next, the Extended Gaussian Image (EGI) descriptor of those voxel clusters are constructed using significant eigenvectors of each voxel in the cluster. Correspondences between clusters in source and target data are obtained according to the similarity between their EGI descriptors. The random sampling consensus (RANSAC) algorithm is employed to remove outlying correspondences until a coarse alignment is obtained. If necessary, a fine registration is performed in a final step. This new method is illustrated on scan data sampling two indoor scenarios. The results of the tests are evaluated by computing the point to point distance between the two input point clouds. The presented two tests resulted in mean distances of 7.6 mm and 9.5 mm respectively, which are adequate for fine registration.

  18. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, Joshua, E-mail: grimes.joshua@mayo.edu [Department of Physics and Astronomy, University of British Columbia, Vancouver V5Z 1L8 (Canada); Celler, Anna [Department of Radiology, University of British Columbia, Vancouver V5Z 1L8 (Canada)

    2014-09-15

    Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90

  19. Growth status of Korean orphans raised in the affluent West: anthropometric trend, multivariate determinants, and descriptive comparison with their North and South Korean peers.

    Science.gov (United States)

    Schwekendiek, Daniel J

    2017-04-01

    This paper investigates the trend in height among adult Korean orphans who were adopted in early life into affluent Western nations. Final heights of 148 females were analyzed based on a Korean government survey conducted in 2008. Height of the orphans was descriptively compared against final heights of South and North Koreans. Furthermore, statistical determinants of orphan height were investigated in multivariate regressions. Mean height of Korean orphans was 160.44 cm (SD 5.89), which was higher than that of South Koreans at 158.83 cm (SD 5.01). Both Korean orphans and South Koreans were taller than North Koreans at 155.30 cm (SD 4.94). However, height of Korean orphans stagnated at around 160-161 cm while those of North and South Koreans improved over time. In the regression analysis, the socioeconomic status of the adoptive family was statistically significant in all models, while dummies for the adoptive nations and age at adoption were insignificant. This study shows that the mean final height of women experiencing extreme environmental improvements in early-life is capped at 160-161 cm, tentatively suggesting that social stress factors in the host nation or early-life factors in the birth nation might have offset some of the environmental enrichment effects achieved through intercountry adoption.

  20. Cost effectiveness methodology for evaluating Korean international communication system alternatives.

    OpenAIRE

    Hwang, Tae Kyun.

    1987-01-01

    Approved for public release; distribution in unlimited. Cost and Effectiveness models are developed by using of cost-effectiveness technique for fiber optic cable and satellite communication media. The models are applied to the Korean international communication problem. Alternative selection is required since the two medias different in cost and effectiveness. The major difficulties encountered were data gathering and measuring the effectiveness of the Korean international ...

  1. Using Edge Voxel Information to Improve Motion Regression for rs-fMRI Connectivity Studies.

    Science.gov (United States)

    Patriat, Rémi; Molloy, Erin K; Birn, Rasmus M

    2015-11-01

    Recent fMRI studies have outlined the critical impact of in-scanner head motion, particularly on estimates of functional connectivity. Common strategies to reduce the influence of motion include realignment as well as the inclusion of nuisance regressors, such as the 6 realignment parameters, their first derivatives, time-shifted versions of the realignment parameters, and the squared parameters. However, these regressors have limited success at noise reduction. We hypothesized that using nuisance regressors consisting of the principal components (PCs) of edge voxel time series would be better able to capture slice-specific and nonlinear signal changes, thus explaining more variance, improving data quality (i.e., lower DVARS and temporal SNR), and reducing the effect of motion on default-mode network connectivity. Functional MRI data from 22 healthy adult subjects were preprocessed using typical motion regression approaches as well as nuisance regression derived from edge voxel time courses. Results were evaluated in the presence and absence of both global signal regression and motion censoring. Nuisance regressors derived from signal intensity time courses at the edge of the brain significantly improved motion correction compared to using only the realignment parameters and their derivatives. Of the models tested, only the edge voxel regression models were able to eliminate significant differences in default-mode network connectivity between high- and low-motion subjects regardless of the use of global signal regression or censoring.

  2. The creation of voxel phantoms for the purpose of environmental dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, E.; Higley, K. [Oregon State University (United States)

    2014-07-01

    Basic geometric shapes have long been used as the standard for calculating radiation dose rates in non-human biota (NHB). Regulation standards have seen a shift recently, towards protection of NHB as its own endpoint. As such, there has been a growing interest in improving the calculations for NHB dose rates. To address calls for additional data, the development of voxelized models for the International Commission on Radiological Protection's (ICRP) twelve reference animal and plants (RAP) has been undertaken. Voxel models of a crab (Metacarcinus magister), flatfish (Pleuronectiformes), trout (Oncorhynchus mykiss), worm (Lumbricina), honey bee (Apis), frog (Anura), and rat, (Rattus) have been created to date. The purpose of this submission is to describe the processes of creating these voxel phantoms from radiological imaging data (i.e., Computed Tomography (CT), Magnetic Resonance Imaging (MRI), etc.). CT/MRI images of the organism are obtained and uploaded into a software package capable of segmenting the images (3D Doctor was used for the crab, flatfish, trout, worm, and honey bee). On each image slice, individual organs and other relevant anatomical features (e.g. bones or other structural tissues) are identified and segmented. Once segmentation is complete, a boundary file that describes the positioning of the organs and tissues in lattice geometry format is exported into software called Voxelizer, created by the Human Monitoring Laboratory of Canada. This software writes the boundary file geometry into an input file for Monte Carlo N-Particle (MCNP) based simulations. The user can then add appropriate materials, densities, and a desired source term. These simulations yield absorbed fraction (AF) values that are used in subsequent dose calculations with environmental concentration data. AFs are now available for the crab, flatfish, trout, worm, and honey bee at twelve photon and nine electron energies, consistent with ICRP AFs for human dosimetry

  3. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice

    Directory of Open Access Journals (Sweden)

    Blaine A. Christiansen

    2016-12-01

    Full Text Available Micro-computed tomography (μCT is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6–30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. Keywords: Trabecular bone, Microstructure, Micro-computed tomography, Voxel size, Resolution

  4. A structural model for stress, coping, and psychosocial adjustment: A multi-group analysis by stages of survivorship in Korean women with breast cancer.

    Science.gov (United States)

    Jang, Miyoung; Kim, Jiyoung

    2018-04-01

    Prospective studies have examined factors directly affecting psychosocial adjustment during breast cancer treatment. Survivorship stage may moderate a direct effect of stress on psychosocial adjustment. This study aimed to examine relationships between stress, social support, self-efficacy, coping, and psychosocial adjustment to construct a model of the effect pathways between those factors, and determine if survivorship stage moderates those effects. Six hundred people with breast cancer completed questionnaires. Examined stages of survivorship after treatment were as follows: acute (i.e., 5 years). Stress (Perceived Stress Scale), social support (Multidimensional Scale of Perceived Social Support), self-efficacy (New General Self Efficacy Scale), coping (Ways of Coping Checklist), and psychosocial adjustment (Psychosocial Adjustment to Illness Scale-Self-Report-Korean Version) were measured. Self-efficacy significantly correlated with psychosocial adjustment in the acute survival stage (γ = -0.37, P psychosocial adjustment was greater in the acute (γ = -0.42, P psychosocial adjustment was stronger in the lasting survival stage (β = 0.42, P psychosocial adjustment of female breast cancer patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Development of a voxel phantom specific for simulation of eye brachytherapy; Desenvolvimeto de um fantoma de voxel especifico para simulacao de braquiterapia ocular

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcilio S.; Lima, Fernando R.A., E-mail: msilveira.fisica@gmail.com, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Vieira, Jose W., E-mail: jose-wilson59@live.com [lnstituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)

    2013-11-01

    The ophthalmic brachytherapy involves inserting a plate with seeds of radioactive material in the patient's eye for the treatment of tumors. The radiation dose to be taken by the patient is prescribed by physicians and time of application of the material is calculated from calibration curves supplied by the manufacturers of the plates. To estimate the dose absorbed by the patient, in a series of diagnostic tests, it is necessary to perform simulations using a computational model of exposure. These models are composed primarily by a anthropomorphic phantom, and a Monte Carlo code. The coupling of a phantom voxel whole body to a Monte Carlo code is a complex process because the computer model simulations with exposure takes time, knowledge of the code used and various adjustments to be implemented. The problem is aggravated even more complex when you want to radiate one region of the body. In this work we developed a phantom, specifically the region containing the eyeball, from MASH (Male Adult voxel). This model was coupled to the Monte Carlo code EGSnrc (Electron Gamma Shower) together with an algorithm simulator source of I-125 , considering only its effect of higher energy range.

  6. A benefit–risk assessment model for statins using multicriteria decision analysis based on a discrete choice experiment in Korean patients

    Directory of Open Access Journals (Sweden)

    Byun JH

    2016-06-01

    Full Text Available Ji-Hye Byun,1 Sun-Hong Kwon,1 Ji-Hye Ha,2 Eui-Kyung Lee1 1School of Pharmacy, Sungkyunkwan University, Suwon-si, Gyeonggi-do, 2Ministry of Food and Drug Safety, Cheongju-si, Chungcheongbuk-do, South Korea Purpose: The benefit–risk balance for drugs can alter post approval owing to additional data on efficacy or adverse events. This study developed a quantitative benefit–risk assessment (BRA model for statins using multicriteria decision analysis with discrete choice experiments and compared a recent BRA with that at the time of approval. Patients and methods: Following a systematic review of the literature, the benefit criteria within the statin BRA model were defined as a reduction in the plasma low-density lipoprotein cholesterol level and a reduction in myocardial infarction incidence; the risk criteria were hepatotoxicity (Liv and fatal rhabdomyolysis (Rha. The scores for these criteria were estimated using mixed treatment comparison methods. Weighting was calculated from a discrete choice experiment involving 203 Korean patients. The scores and weights were integrated to produce an overall value representing the benefit–risk balance, and sensitivity analyses were conducted. Results: In this BRA model, low-density lipoprotein (relative importance [RI]: 37.50% was found to be a more important benefit criterion than myocardial infarction (RI: 35.43%, and Liv (RI: 16.28% was a more important risk criterion than Rha (RI: 10.79%. Patients preferred atorvastatin, and the preference ranking of cerivastatin and simvastatin was switched post approval because of the emergence of additional risk information related to cerivastatin. Conclusion: A quantitative statin BRA model confirmed that the preference ranking of statins changed post approval because of the identification of additional benefits or risks. Keywords: multicriteria decision analysis, statin, quantitative benefit–risk assessment, discrete choice experiment

  7. SU-E-CAMPUS-I-02: Estimation of the Dosimetric Error Caused by the Voxelization of Hybrid Computational Phantoms Using Triangle Mesh-Based Monte Carlo Transport

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C [Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD (United States); Badal, A [U.S. Food ' Drug Administration (CDRH/OSEL), Silver Spring, MD (United States)

    2014-06-15

    Purpose: Computational voxel phantom provides realistic anatomy but the voxel structure may result in dosimetric error compared to real anatomy composed of perfect surface. We analyzed the dosimetric error caused from the voxel structure in hybrid computational phantoms by comparing the voxel-based doses at different resolutions with triangle mesh-based doses. Methods: We incorporated the existing adult male UF/NCI hybrid phantom in mesh format into a Monte Carlo transport code, penMesh that supports triangle meshes. We calculated energy deposition to selected organs of interest for parallel photon beams with three mono energies (0.1, 1, and 10 MeV) in antero-posterior geometry. We also calculated organ energy deposition using three voxel phantoms with different voxel resolutions (1, 5, and 10 mm) using MCNPX2.7. Results: Comparison of organ energy deposition between the two methods showed that agreement overall improved for higher voxel resolution, but for many organs the differences were small. Difference in the energy deposition for 1 MeV, for example, decreased from 11.5% to 1.7% in muscle but only from 0.6% to 0.3% in liver as voxel resolution increased from 10 mm to 1 mm. The differences were smaller at higher energies. The number of photon histories processed per second in voxels were 6.4×10{sup 4}, 3.3×10{sup 4}, and 1.3×10{sup 4}, for 10, 5, and 1 mm resolutions at 10 MeV, respectively, while meshes ran at 4.0×10{sup 4} histories/sec. Conclusion: The combination of hybrid mesh phantom and penMesh was proved to be accurate and of similar speed compared to the voxel phantom and MCNPX. The lowest voxel resolution caused a maximum dosimetric error of 12.6% at 0.1 MeV and 6.8% at 10 MeV but the error was insignificant in some organs. We will apply the tool to calculate dose to very thin layer tissues (e.g., radiosensitive layer in gastro intestines) which cannot be modeled by voxel phantoms.

  8. Comparison of Baseline Characteristics between Community-based and Hospital-based Suicidal Ideators and Its Implications for Tailoring Strategies for Suicide Prevention: Korean Cohort for the Model Predicting a Suicide and Suicide-related Behavior.

    Science.gov (United States)

    Park, C Hyung Keun; Lee, Jae Won; Lee, Sang Yeol; Moon, Jungjoon; Shim, Se Hoon; Paik, Jong Woo; Kim, Shin Gyeom; Cho, Seong Jin; Kim, Min Hyuk; Kim, Seokho; Park, Jae Hyun; You, Sungeun; Jeon, Hong Jin; Ahn, Yong Min

    2017-09-01

    In this cross-sectional study, we aimed to identify distinguishing factors between populations with suicidal ideation recruited from hospitals and communities to make an efficient allocation of limited anti-suicidal resources according to group differences. We analyzed the baseline data from 120 individuals in a community-based cohort (CC) and 137 individuals in a hospital-based cohort (HC) with suicidal ideation obtained from the Korean Cohort for the Model Predicting a Suicide and Suicide-related Behavior (K-COMPASS) study. First, their sociodemographic factors, histories of medical and psychiatric illnesses, and suicidal behaviors were compared. Second, diagnosis by the Korean version of the Mini International Neuropsychiatric Interview, scores of psychometric scales were used to assess differences in clinical severity between the groups. The results revealed that the HC had more severe clinical features: more psychiatric diagnosis including current and recurrent major depressive episodes (odds ratio [OR], 4.054; P suicide risk (OR, 4.817; P suicidality. © 2017 The Korean Academy of Medical Sciences.

  9. Adaptation in South Korean Society of North Korean Elite Defectors

    Directory of Open Access Journals (Sweden)

    Levi Nicolas

    2017-10-01

    Full Text Available This paper aims to explain the adaptation of North Korean elite defectors who fled from North Korea. Data used for the purpose of this article came from surveys of North Korean defectors conducted in the late 2000’s. Findings of the realized research indicate that the majority of senior defectors are experiencing less psychological and material issues when adjusting to society than regular North Korean defectors. The paper will proceed in three steps: explaining the notion of defectors, outlining their background, and focusing on their adaptation in South. Although defectors as a whole has emerged as of the most research group as a minority in South Korea, the so-called senior defectors have hardly been spotlighted. Basically North Korean senior defectors are supposed to strengthen the anti-Kim movement and legitimize the power of the South Korean government and the image of South Korea abroad. What has to be enlightened upon is the fact that North Korean senior defectors partially disagree with the integration policy of South Korean authorities. A major research question emerges: How are the experience of elite defectors localized in South Korea? How do their specific identities impact their opinion within the South Korean society? The aim of the article is also to categorize senior defectors and to provide in a single document a list of senior North Korea defectors based abroad. This kind of information is only available for Korean speaking readers. I wanted to make it accessible to the Englishspeaking community.

  10. Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements

    International Nuclear Information System (INIS)

    Rajon, D.A.; Shah, A.P.; Watchman, C.J.; Bolch, W.E.; Jokisch, D.W.; Patton, P.W.

    2002-01-01

    Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values. (author)

  11. Defense Acquisition Policy and Defense Industrial Base Reinforcement Strategy - Enhancing the International Competitiveness of the Korean National Defense Industry

    National Research Council Canada - National Science Library

    Lee, Dae O

    2008-01-01

    ...) through competitiveness analysis is required. Thus, it is necessary to develop appropriate models for analyzing the Korean NDI and to conduct competitiveness analysis by using the developed model...

  12. An Improved Optimization Method for the Relevance Voxel Machine

    DEFF Research Database (Denmark)

    Ganz, Melanie; Sabuncu, M. R.; Van Leemput, Koen

    2013-01-01

    In this paper, we will re-visit the Relevance Voxel Machine (RVoxM), a recently developed sparse Bayesian framework used for predicting biological markers, e.g., presence of disease, from high-dimensional image data, e.g., brain MRI volumes. The proposed improvement, called IRVoxM, mitigates the ...

  13. Voxel Advanced Digital-manufacturing for Earth & Regolith in Space

    Data.gov (United States)

    National Aeronautics and Space Administration — A voxel is a discrete three-dimensional (3D) element of material that is used to construct a larger 3D object. It is the 3D equivalent of a pixel. This project will...

  14. A Morphological Approach to the Voxelization of Solids

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Sramek, Milos; Christensen, Niels Jørgen

    2000-01-01

    In this paper we present a new, morphological criterion for determining whether a geometric solid is suitable for voxelization at a given resolution. The criterion embodies two conditions, namely that the curvature of the solid must be bounded and the critical points of the distance field must be...

  15. Giga-voxel computational morphogenesis for structural design

    Science.gov (United States)

    Aage, Niels; Andreassen, Erik; Lazarov, Boyan S.; Sigmund, Ole

    2017-10-01

    In the design of industrial products ranging from hearing aids to automobiles and aeroplanes, material is distributed so as to maximize the performance and minimize the cost. Historically, human intuition and insight have driven the evolution of mechanical design, recently assisted by computer-aided design approaches. The computer-aided approach known as topology optimization enables unrestricted design freedom and shows great promise with regard to weight savings, but its applicability has so far been limited to the design of single components or simple structures, owing to the resolution limits of current optimization methods. Here we report a computational morphogenesis tool, implemented on a supercomputer, that produces designs with giga-voxel resolution—more than two orders of magnitude higher than previously reported. Such resolution provides insights into the optimal distribution of material within a structure that were hitherto unachievable owing to the challenges of scaling up existing modelling and optimization frameworks. As an example, we apply the tool to the design of the internal structure of a full-scale aeroplane wing. The optimized full-wing design has unprecedented structural detail at length scales ranging from tens of metres to millimetres and, intriguingly, shows remarkable similarity to naturally occurring bone structures in, for example, bird beaks. We estimate that our optimized design corresponds to a reduction in mass of 2-5 per cent compared to currently used aeroplane wing designs, which translates into a reduction in fuel consumption of about 40-200 tonnes per year per aeroplane. Our morphogenesis process is generally applicable, not only to mechanical design, but also to flow systems, antennas, nano-optics and micro-systems.

  16. Predicting a roadkill hotspots based on spatial distribution of Korean water deer (Hydropotes inermis argyropus) using Maxent model in South Korea Expressway : In Case of Cheongju-Sangju Expressway

    Science.gov (United States)

    Park, Hyomin; Lee, Sangdon

    2016-04-01

    Road construction has direct and indirect effects on ecosystems. Especially wildlife-vehicle conflicts (roadkills) caused by roads are a considerable threat for population of many species. This study aims to identify the effects of topographic characteristics and spatial distribution of Korean water deer (Hydropotes inermis). Korean water deer is indigenous and native species in Korea that listed LC (least concern) by IUCN redlist categories. Korean water deer population is growing every year occupying for most of roadkills (>70%) in Korean express highway. In order to predict a distribution of the Korean water deer, we selected factors that most affected water deer's habitat. Major habitats of waterdeer are known as agricultural area, forest area and water. Based on this result, eight factors were selected (land cover map, vegetation map, age class of forest, diameter class of tree, population, slope of study site, elevation of study site, distance of river), and made a thematic map by using GIS program (ESRI, Arc GIS 10.3.1 ver.). To analyze the affected factors of waterdeer distribution, GPS data and thematic map of study area were entered into Maxent model (Maxent 3.3.3.k.). Results of analysis were verified by the AUC (Area Unit Curve) of ROC (Receiver Operating Characteristic). The ROC curve used the sensitivity and specificity as a reference for determining the prediction efficiency of the model and AUC area of ROC curve was higher prediction efficiency closer to '1.' Selecting factors that affected the distribution of waterdeer were land cover map, diameter class of tree and elevation of study site. The value of AUC was 0.623. To predict the water deer's roadkills hot spot on Cheongju-Sangju Expressway, the thematic map was prepared based on GPS data of roadkill spots. As a result, the topographic factors that affected waterdeer roadkill were land cover map, actual vegetation map and age class of forest and the value of AUC was 0.854. Through this study, we

  17. The Korean Peninsula

    International Nuclear Information System (INIS)

    Jeon Bu-Guan

    1994-01-01

    A realistic approach to North-South arms control and disarmament would require a step-by-step formula encompassing measures for political and military confidence building, arms limitation and reduction. The most fundamental and important condition for achieving meaningful results in disarmament talks is securing political and military confidence. The problem which arose on the Korean peninsula originates from relations of North Korea and IAEA. North Korean position poses a serious threat to the Non-proliferation Treaty, in particular to the IAEA Safeguards regime. Nuclear non-proliferation and the ultimate elimination of nuclear weapons are the primary concerns of the post-cold war era. The Government of South Korea hopes that this issue can be solved through dialogue and negotiations

  18. Preparing a voxel-simulator of Alderson Rando physical phantom

    International Nuclear Information System (INIS)

    Boia, Leonardo S.; Martins, Maximiano C.; Silva, Ademir X.; Salmon Junior, Helio A.; Soares, Alessandro F.N.S.

    2011-01-01

    There are, nowadays, sorts of anthropomorphycal phantoms which are used for simulation of radiation transport by the matter and also the deposition of energy in such radiation in human tissues and organs, because an in-vitro dosimetry becomes very either complicated or even impossible in some cases. In the present work we prepared a computational phantom in voxels based on computational tomography of Rando-Alderson. This phantom is one of the most known human body simulators on the scope of ionizing radiation dosimetry, and it is used for radioprotection issues and dosimetry from radiotherapy and brachytherapy treatments as well. The preparation of a voxel simulator starts with the image acquisition by a tomograph found at COI/RJ (Clinicas Oncologicas Integradas). The images were generated with 1mm cuts and collected for analysis. After that step the images were processed in SAPDI (Sistema Automatizado de Processamento Digital de Imagem) in order to amplify the images regions intending to facilitate the task in their segmentation. SAPDI is based on parameters described by Hounsfield scale. After that, it has begun discretization of elements in IDs voxels using Scan2MCNP software - which converts images to a sequential text file containing the voxels' IDs ready to be introduced into MCNPX input; however, this set can be turned to a voxel's IDs matrix and used in other Monte Carlo codes, such as Geant4, PENELOPE and EGSnrc. Finished this step, the simulator is able to simulate with accurate geometry the physical phantom. It's possible to study a large number of cases by computational techniques of geometry's insertions of tumors and TLDs, which makes this simulator a research material useful for a lot of subjects. (author)

  19. Preparing a voxel-simulator of Alderson Rando physical phantom

    Energy Technology Data Exchange (ETDEWEB)

    Boia, Leonardo S.; Martins, Maximiano C.; Silva, Ademir X., E-mail: lboia@con.ufrj.br, E-mail: ademir@con.ufrj.br [Programa de Engenharia Nuclear (PEN/COPPE/UFRJ). Universidade Federal do Rio de Janeiro, RJ (Brazil); Salmon Junior, Helio A., E-mail: heliosalmon@coinet.com.br [COI - Clinicas Oncologicas Integradas, MD.X Barra Medical Center, Rio de Janeiro, RJ (Brazil); Soares, Alessandro F.N.S., E-mail: afacure@cnen.gov.br [Comissao Nacional de Engenharia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    There are, nowadays, sorts of anthropomorphycal phantoms which are used for simulation of radiation transport by the matter and also the deposition of energy in such radiation in human tissues and organs, because an in-vitro dosimetry becomes very either complicated or even impossible in some cases. In the present work we prepared a computational phantom in voxels based on computational tomography of Rando-Alderson. This phantom is one of the most known human body simulators on the scope of ionizing radiation dosimetry, and it is used for radioprotection issues and dosimetry from radiotherapy and brachytherapy treatments as well. The preparation of a voxel simulator starts with the image acquisition by a tomograph found at COI/RJ (Clinicas Oncologicas Integradas). The images were generated with 1mm cuts and collected for analysis. After that step the images were processed in SAPDI (Sistema Automatizado de Processamento Digital de Imagem) in order to amplify the images regions intending to facilitate the task in their segmentation. SAPDI is based on parameters described by Hounsfield scale. After that, it has begun discretization of elements in IDs voxels using Scan2MCNP software - which converts images to a sequential text file containing the voxels' IDs ready to be introduced into MCNPX input; however, this set can be turned to a voxel's IDs matrix and used in other Monte Carlo codes, such as Geant4, PENELOPE and EGSnrc. Finished this step, the simulator is able to simulate with accurate geometry the physical phantom. It's possible to study a large number of cases by computational techniques of geometry's insertions of tumors and TLDs, which makes this simulator a research material useful for a lot of subjects. (author)

  20. Korean soft weather

    International Nuclear Information System (INIS)

    Pressburg, A.P.

    2007-01-01

    In this paper author deals with the development of nuclear weapons in the Korean People Democratic Republic (North Korea), which was crowned in October 2006 with the first successful underground detonation of nuclear charge. The North Korea so walked into the elite club and became de facto the nuclear great power. Nuclear disarmament negotiations with North Korea misfired. Relationships between the North Korea and the Republic of Korea as well as the China are discussed

  1. Koreans in Japan: Their Influence on Korean-Japanese Relations.

    Science.gov (United States)

    1979-09-01

    1963. 31. The Republic of Korea National Red Cross, The Dispersed Families in Korea, Seoul, 1977. 32. Sato , Shoki, Koreans in Japan - The...1975. 34. Sumiya, Mikio , Kankoku no Keizai (The Korean Economy), Iwanami Shoten, Tokyo, Japan, 1974. 35. U.S. Government Printing Office, U.S. Army Area

  2. Korean/Korean American Adolescents' Responses to Young Adult Fiction and Media Created by Korean/Korean Americans

    Science.gov (United States)

    Kim, Eunhyun

    2010-01-01

    Multicultural children's and young adult literature provides readers with various opportunities: to mirror their lives and reflect the meanings of their own experiences; to gain insight on social issues as well as personal issues; and to enhance cross-cultural awareness. How might Korean/Korean American youth cope with everyday life as a minority…

  3. Micro-CT Pore Scale Study Of Flow In Porous Media: Effect Of Voxel Resolution

    Science.gov (United States)

    Shah, S.; Gray, F.; Crawshaw, J.; Boek, E.

    2014-12-01

    In the last few years, pore scale studies have become the key to understanding the complex fluid flow processes in the fields of groundwater remediation, hydrocarbon recovery and environmental issues related to carbon storage and capture. A pore scale study is often comprised of two key procedures: 3D pore scale imaging and numerical modelling techniques. The essence of a pore scale study is to test the physics implemented in a model of complicated fluid flow processes at one scale (microscopic) and then apply the model to solve the problems associated with water resources and oil recovery at other scales (macroscopic and field). However, the process of up-scaling from the pore scale to the macroscopic scale has encountered many challenges due to both pore scale imaging and modelling techniques. Due to the technical limitations in the imaging method, there is always a compromise between the spatial (voxel) resolution and the physical volume of the sample (field of view, FOV) to be scanned by the imaging methods, specifically X-ray micro-CT (XMT) in our case In this study, a careful analysis was done to understand the effect of voxel size, using XMT to image the 3D pore space of a variety of porous media from sandstones to carbonates scanned at different voxel resolution (4.5 μm, 6.2 μm, 8.3 μm and 10.2 μm) but keeping the scanned FOV constant for all the samples. We systematically segment the micro-CT images into three phases, the macro-pore phase, an intermediate phase (unresolved micro-pores + grains) and the grain phase and then study the effect of voxel size on the structure of the macro-pore and the intermediate phases and the fluid flow properties using lattice-Boltzmann (LB) and pore network (PN) modelling methods. We have also applied a numerical coarsening algorithm (up-scale method) to reduce the computational power and time required to accurately predict the flow properties using the LB and PN method.

  4. Segmentation Based Classification of 3D Urban Point Clouds: A Super-Voxel Based Approach with Evaluation

    Directory of Open Access Journals (Sweden)

    Laurent Trassoudaine

    2013-03-01

    Full Text Available Segmentation and classification of urban range data into different object classes have several challenges due to certain properties of the data, such as density variation, inconsistencies due to missing data and the large data size that require heavy computation and large memory. A method to classify urban scenes based on a super-voxel segmentation of sparse 3D data obtained from LiDAR sensors is presented. The 3D point cloud is first segmented into voxels, which are then characterized by several attributes transforming them into super-voxels. These are joined together by using a link-chain method rather than the usual region growing algorithm to create objects. These objects are then classified using geometrical models and local descriptors. In order to evaluate the results, a new metric that combines both segmentation and classification results simultaneously is presented. The effects of voxel size and incorporation of RGB color and laser reflectance intensity on the classification results are also discussed. The method is evaluated on standard data sets using different metrics to demonstrate its efficacy.

  5. [Voxel-Based Morphometry in Autism Spectrum Disorder].

    Science.gov (United States)

    Yamasue, Hidenori

    2017-05-01

    Autism spectrum disorder shows deficits in social communication and interaction including nonverbal communicative behaviors (e.g., eye contact, gestures, voice prosody, and facial expressions) and restricted and repetitive behaviors as its core symptoms. These core symptoms are emerged as an atypical behavioral development in toddlers with the disorder. Atypical neural development is considered to be a neural underpinning of such behaviorally atypical development. A number of studies using voxel-based morphometry have already been conducted to compare regional brain volumes between individuals with autism spectrum disorder and those with typical development. Furthermore, more than ten papers employing meta-analyses of the comparisons using voxel based morphometry between individuals with autism spectrum disorder and those with typical development have already been published. The current review paper adds some brief discussions about potential factors contributing to the inconsistency observed in the previous findings such as difficulty in controlling the confounding effects of different developmental phases among study participants.

  6. Monte Carlo simulation of dose calculation in voxel and geometric phantoms using GEANT4 code

    International Nuclear Information System (INIS)

    Martins, Maximiano C.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Silva, Rosana de S. e; Begalli, Marcia

    2009-01-01

    Monte Carlo simulation techniques have become a valuable tool for scientific purposes. In radiation protection many quantities are obtained by means of the simulation of particles passing through human body models, also known as phantoms, allowing the calculation of doses deposited in an individual's organs exposed to ionizing radiation. These information are very useful from the medical viewpoint, as they are used in the planning of external beam radiotherapy and brachytherapy treatments. The goal of this work is the implementation of a voxel phantom and a geometrical phantom in the framework of the Geant4 tool kit, aiming at a future use of this code by professionals in the medical area. (author)

  7. Rapid Assemblers for Voxel-Based VLSI Robotics

    Science.gov (United States)

    2014-02-12

    flux vector given by the Nernst -Planck equation ( equation ), where the partial derivative of the concentration of ions with respect to time plus the...species i given by the Nernst -Einstein equation . The boundary conditions are that the diffusive and convective contribu- tions to the flux are zero at...dependent partial differential equations . SIAM Journal of Numerical Analysis, 32(3):797-823, 1995. Task 2: cm-scale voxels for prototypes Task

  8. Analysis of multiplex gene expression maps obtained by voxelation

    OpenAIRE

    An, L; Xie, H; Chin, MH; Obradovic, Z; Smith, DJ; Megalooikonomou, V

    2009-01-01

    Abstract Background Gene expression signatures in the mammalian brain hold the key to understanding neural development and neurological disease. Researchers have previously used voxelation in combination with microarrays for acquisition of genome-wide atlases of expression patterns in the mouse brain. On the other hand, some work has been performed on studying gene functions, without taking into account the location information of a gene's expression in a mouse brain. In this paper, we presen...

  9. Development of a voxel phantom specific for simulation of eye brachytherapy

    International Nuclear Information System (INIS)

    Santos, Marcilio S.; Lima, Fernando R.A.

    2013-01-01

    The ophthalmic brachytherapy involves inserting a plate with seeds of radioactive material in the patient's eye for the treatment of tumors. The radiation dose to be taken by the patient is prescribed by physicians and time of application of the material is calculated from calibration curves supplied by the manufacturers of the plates. To estimate the dose absorbed by the patient, in a series of diagnostic tests, it is necessary to perform simulations using a computational model of exposure. These models are composed primarily by a anthropomorphic phantom, and a Monte Carlo code. The coupling of a phantom voxel whole body to a Monte Carlo code is a complex process because the computer model simulations with exposure takes time, knowledge of the code used and various adjustments to be implemented. The problem is aggravated even more complex when you want to radiate one region of the body. In this work we developed a phantom, specifically the region containing the eyeball, from MASH (Male Adult voxel). This model was coupled to the Monte Carlo code EGSnrc (Electron Gamma Shower) together with an algorithm simulator source of I-125 , considering only its effect of higher energy range

  10. On the evolution of cured voxel in bulk photopolymerization upon focused Gaussian laser exposure

    Energy Technology Data Exchange (ETDEWEB)

    Bhole, Kiran, E-mail: kirandipali@gmail.com; Gandhi, Prasanna [Suman Mashruwala Advance Microengineering Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra 400076 (India); Kundu, T. [Department of Physics, Indian Institute of Technology Bombay, Mumbai, Maharashtra 400076 (India)

    2014-07-28

    Unconstrained depth photopolymerization is emerging as a promising technique for fabrication of several polymer microstructures such as self propagating waveguides, 3D freeform structures by bulk lithography, and polymer nanoparticles by flash exposure. Experimental observations reveal governing physics beyond Beer Lambert's law and scattering effects. This paper seeks to model unconstrained depth photopolymerization using classical nonlinear Schrödinger equation coupled with transient diffusion phenomenon. The beam propagation part of the proposed model considers scattering effects induced due to spatial variation of the refractive index as a function of the beam intensity. The critical curing energy model is used to further predict profile of polymerized voxel. Profiles of photopolymerized voxel simulated using proposed model are compared with the corresponding experimental results for several cases of exposure dose and duration. The comparison shows close match leading to conclusion that the experimentally observed deviation from Beer Lambert's law is indeed due to combined effect of diffusion of photoinitiator and scattering of light because of change in the refractive index.

  11. On the evolution of cured voxel in bulk photopolymerization upon focused Gaussian laser exposure

    International Nuclear Information System (INIS)

    Bhole, Kiran; Gandhi, Prasanna; Kundu, T.

    2014-01-01

    Unconstrained depth photopolymerization is emerging as a promising technique for fabrication of several polymer microstructures such as self propagating waveguides, 3D freeform structures by bulk lithography, and polymer nanoparticles by flash exposure. Experimental observations reveal governing physics beyond Beer Lambert's law and scattering effects. This paper seeks to model unconstrained depth photopolymerization using classical nonlinear Schrödinger equation coupled with transient diffusion phenomenon. The beam propagation part of the proposed model considers scattering effects induced due to spatial variation of the refractive index as a function of the beam intensity. The critical curing energy model is used to further predict profile of polymerized voxel. Profiles of photopolymerized voxel simulated using proposed model are compared with the corresponding experimental results for several cases of exposure dose and duration. The comparison shows close match leading to conclusion that the experimentally observed deviation from Beer Lambert's law is indeed due to combined effect of diffusion of photoinitiator and scattering of light because of change in the refractive index.

  12. North Korean Policy Elites

    Science.gov (United States)

    2004-06-01

    by Kim’s former Japanese chef , Kenji Fujimoto, reveal that Kim could get just about anything he wanted in his personal life, from foreign delicacies...for his table to Japanese jet skis and Sony home electronics.9 Likewise, the account of Yi Nam-oak (Li Nam-ok), who grew up as a companion to Kim’s...title Kin Seinichi no Ryoryinin [Kim Jong-il’s Chef ], Tokyo: Fusosha, 2003. The title of the Korean edition is Kim Jong-il ui yorisa. FBIS translated

  13. Korean Affairs Report

    Science.gov (United States)

    1986-09-09

    U.S. Volvo 13. Other 14. Subtotal 15. Toyota 16. Nissan 17. Honda 18. Mazda 19. Mitsubishi 20. Fujitsu 21. Isuzu 22. Suzuki 23. Japanese...cars & Percent Unit=1,000 3. Company 4. U.S.-Made Cars 5. Imported Cars 6. GM 7. Ford 8. Chrysler 9. AMC 10. U.S. Nissan 11. U.S. Honda 12...24 percent. This is a surprisingly large increase compared with the current 1.7 percent. Until 1983, the prospect of Korean automobile exports was

  14. Assessment of the announced North Korean nuclear test using long-range atmospheric transport and dispersion modelling.

    Science.gov (United States)

    De Meutter, Pieter; Camps, Johan; Delcloo, Andy; Termonia, Piet

    2017-08-18

    On 6 January 2016, the Democratic People's Republic of Korea announced to have conducted its fourth nuclear test. Analysis of the corresponding seismic waves from the Punggye-ri nuclear test site showed indeed that an underground man-made explosion took place, although the nuclear origin of the explosion needs confirmation. Seven weeks after the announced nuclear test, radioactive xenon was observed in Japan by a noble gas measurement station of the International Monitoring System. In this paper, atmospheric transport modelling is used to show that the measured radioactive xenon is compatible with a delayed release from the Punggye-ri nuclear test site. An uncertainty quantification on the modelling results is given by using the ensemble method. The latter is important for policy makers and helps advance data fusion, where different nuclear Test-Ban-Treaty monitoring techniques are combined.

  15. Prediction model for exhausted point of ion exchange resin column of moderator purification circuit at Korean CANDU plant

    International Nuclear Information System (INIS)

    Sohn, Wook; Kang, Duck-Won; Ahn, Hyun Kyoung; Rhee, In Hyoung

    2005-01-01

    Most of the carbon-14 produced at CANDU plants are removed by an Ion eXchange (IX) resin column of the moderator purification circuit, and a column is replaced based on an empirical guideline. Since the amount of carbon-14 released from CANDU plants is governed by the performance of a column, optimal operation of IX resin columns through the timely replacement based on an objective criterion is very important. For this, the model for predicting the exhausted point of an IX resin column has been developed based on local chemical equilibrium. The performance evaluation at Wolsong Unit 3 showed that the model was able to simulate the removal of species by an IX resin column to such a high degree that the model could provide an objective criterion to replace an IX resin column timely. The derived maximum service time of a fresh IX resin column was 4,080 h, about twice that of the existing empirical guideline (up to 2,000h). Accordingly, if the maximum service time derived in this paper is applied to Wolsong Unit 3, it is expected to reduce the cost needed for the replacement of IX resin column by about 50%. (author)

  16. Detection of superior genotype of fatty acid synthase in Korean native cattle by an environment-adjusted statistical model

    Directory of Open Access Journals (Sweden)

    Jea-Young Lee

    2017-06-01

    Full Text Available Objective This study examines the genetic factors influencing the phenotypes (four economic traits:oleic acid [C18:1], monounsaturated fatty acids, carcass weight, and marbling score of Hanwoo. Methods To enhance the accuracy of the genetic analysis, the study proposes a new statistical model that excludes environmental factors. A statistically adjusted, analysis of covariance model of environmental and genetic factors was developed, and estimated environmental effects (covariate effects of age and effects of calving farms were excluded from the model. Results The accuracy was compared before and after adjustment. The accuracy of the best single nucleotide polymorphism (SNP in C18:1 increased from 60.16% to 74.26%, and that of the two-factor interaction increased from 58.69% to 87.19%. Also, superior SNPs and SNP interactions were identified using the multifactor dimensionality reduction method in Table 1 to 4. Finally, high- and low-risk genotypes were compared based on their mean scores for each trait. Conclusion The proposed method significantly improved the analysis accuracy and identified superior gene-gene interactions and genotypes for each of the four economic traits of Hanwoo.

  17. Two Golden Ages of Korean Cinema

    Directory of Open Access Journals (Sweden)

    Kelly Y. Jeong

    2015-03-01

    Full Text Available The two books by Steven Chung and Young-a Park that I discuss in this essay signal the growth of Korean studies by simply beginning in medias res. That is, unlike many books that came before them, they offer no lengthy exposition to set things up, to declare and justify the need for the study at hand. These new books also reflect the recent scholarly trend of reaching beyond the established area studies or Korean studies models to present studies that are interdisciplinary and transnational in scope. Park’s Unexpected Alliances is a narrative at once of South Korea’s transition to a (truly civil society, of its artistic struggle for independence and integrity, of the individual’s negotiations with the state, and of feminist awakenings in unlikely circumstances. Chung’s Split Screen Korea, which I will discuss first, is similarly expansive in scope...

  18. The Effects of Chunghyul-Dan, an Agent of Korean Medicine, on a Mouse Model of Traumatic Brain Injury

    Directory of Open Access Journals (Sweden)

    Won-Woo Choi

    2017-01-01

    Full Text Available Chunghyul-Dan (CHD is the first choice agent for the prevention and treatment of stroke at the Kyung Hee Medical Hospital. To date, CHD has been reported to have beneficial effects on brain disease in animals and humans, along with antioxidative and anti-inflammatory effects. The aim of this study was to evaluate the pharmacological effects of CHD on a traumatic brain injury (TBI mouse model to explore the possibility of CHD use in patients with TBI. The TBI mouse model was induced using the controlled cortical impact method. CHD was orally administered twice a day for 5 d after TBI induction; mice were assessed for brain damage, brain edema, blood-brain barrier (BBB damage, motor deficits, and cognitive impairment. Treatment with CHD reduced brain damage seen on histological examination and improved motor and cognitive functions. However, CHD did not reduce brain edema and BBB damage. In conclusion, CHD could be a candidate agent in the treatment of patients with TBI. Further studies are needed to assess the exact mechanisms of the effects during the acute-subacute phase and pharmacological activity during the chronic-convalescent phase of TBI.

  19. Monte Carlo study of voxel S factor dependence on tissue density and atomic composition

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto, E-mail: eamato@unime.it [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences, via Consolare Valeria, 1, I-98125 Messina (Italy); Italiano, Antonio [INFN – Istituto Nazionale di Fisica Nucleare, Gruppo Collegato di Messina (Italy); Baldari, Sergio [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences, via Consolare Valeria, 1, I-98125 Messina (Italy)

    2013-11-21

    Voxel dosimetry is a common approach to the internal dosimetry of non-uniform activity distributions in nuclear medicine therapies with radiopharmaceuticals and in the estimation of the radiation hazard due to internal contamination of radionuclides. Aim of the present work is to extend our analytical approach for the calculation of voxel S factors to materials different from the soft tissue. We used a Monte Carlo simulation in GEANT4 of a voxelized region of each material in which the source of monoenergetic electrons or photons was uniformly distributed within the central voxel, and the energy deposition was scored over the surrounding 11×11×11 voxels. Voxel S factors were obtained for the following standard ICRP materials: Adipose tissue, Bone cortical, Brain, Lung, Muscle skeletal and Tissue soft with 1 g cm{sup −3} density. Moreover, we considered the standard ICRU materials: Bone compact and Muscle striated. Voxel S factors were represented as a function of the “normalized radius”, defined as the ratio between the source–target voxel distance and the voxel side. We found that voxel S factors and related analytical fit functions are mainly affected by the tissue density, while the material composition gives only a slight contribution to the difference between data series, which is negligible for practical purposes. Our results can help in broadening the dosimetric three-dimensional approach based on voxel S factors to other tissues where diagnostic and therapeutic radionuclides can be taken up and radiation can propagate.

  20. Monte Carlo study of voxel S factor dependence on tissue density and atomic composition

    International Nuclear Information System (INIS)

    Amato, Ernesto; Italiano, Antonio; Baldari, Sergio

    2013-01-01

    Voxel dosimetry is a common approach to the internal dosimetry of non-uniform activity distributions in nuclear medicine therapies with radiopharmaceuticals and in the estimation of the radiation hazard due to internal contamination of radionuclides. Aim of the present work is to extend our analytical approach for the calculation of voxel S factors to materials different from the soft tissue. We used a Monte Carlo simulation in GEANT4 of a voxelized region of each material in which the source of monoenergetic electrons or photons was uniformly distributed within the central voxel, and the energy deposition was scored over the surrounding 11×11×11 voxels. Voxel S factors were obtained for the following standard ICRP materials: Adipose tissue, Bone cortical, Brain, Lung, Muscle skeletal and Tissue soft with 1 g cm −3 density. Moreover, we considered the standard ICRU materials: Bone compact and Muscle striated. Voxel S factors were represented as a function of the “normalized radius”, defined as the ratio between the source–target voxel distance and the voxel side. We found that voxel S factors and related analytical fit functions are mainly affected by the tissue density, while the material composition gives only a slight contribution to the difference between data series, which is negligible for practical purposes. Our results can help in broadening the dosimetric three-dimensional approach based on voxel S factors to other tissues where diagnostic and therapeutic radionuclides can be taken up and radiation can propagate

  1. Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    Science.gov (United States)

    Niwayama, Masatsugu

    2018-03-01

    We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carlo simulations. It was found that the measurement sensitivity can be represented as the product of the change in the absorption coefficient and the difference in optical path length in two states with different source-detector distances. The results clarified the sensitivity ratio between the surface layer and the deep layer at each source-detector distance for each model and identified changes in the deep measurement area when one of the detectors was close to the light source. A comparison was made with the results from continuous-wave spectroscopy. The study also identified measurement challenges that arise when the surface layer is inhomogeneous. Findings on the measurement sensitivity of SRS at each voxel and in each layer can support the correct interpretation of measured values when near-infrared oximetry or functional near-infrared spectroscopy is used to investigate different tissue structures. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  2. Development of the two Korean adult tomographic computational phantoms for organ dosimetry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Park, Sang-Hyun; Lee, Jai-Ki

    2006-01-01

    Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300x150x344 voxels with a voxel resolution of 2x2x5 mm 3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and

  3. Development of Korean EDMG

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yunjung; Jee, Moonhak; Kim, Inhwan; Park, Munhee [Nuclear Safety Technology Research Laboratory, Daejeon (Korea, Republic of); Kim, Moonoh [Atomic Creative Technology, Seoul (Korea, Republic of)

    2014-05-15

    Safety feature is also needed to more effectively cope with site-wide events affecting multiple units. In this study, the accident mitigation approaches in US are reviewed. The most effective ways to strengthen the defense-in-depth of nuclear power installations are presented as EDMG(Extensive Damage Mitigation Guideline) and FLEX against extreme hazards such as a beyond-design-basis external event (BDBEE) that took place at Fukushima. A combination of the US EDMG and FLEX is applied to develop Korean EDMG, which will be developed to have two different types of EDMGs : 'Site EDMG' to be used for effective technical support to activated TSCs and management of corporate emergency response resources in coordination with the EOF as necessary; and 'Plant-Specific EDMG (for Extreme Event)' to be used by the Technical Support Center (TSC) of a unit where a total loss of control has occurred or plant control cannot be established from the Control Room and Remote Shutdown Panel. The development of Korean EDMG is expected to further enhance mitigation and coping capabilities against site-wide extreme hazard in Korea where a relatively large number of units are assembled on each nuclear power plant site.

  4. Use pattern and predictors of use of highly caffeinated energy drinks among South Korean adolescents: a study using the Health Belief Model.

    Science.gov (United States)

    Ha, Dongmun; Song, Inmyung; Jang, Gyeongil; Lee, Eui-Kyung; Shin, Ju-Young

    2017-09-24

    Concerns about the use of highly caffeinated energy drinks among Korean adolescents remains. We compared adolescents' perceptions regarding the use of drinks to their behaviours and factors. A structured questionnaire based on the Health Belief Model was administered to 850 freshmen and sophomores at three high schools in Bucheon, South Korea. Benefits were defined as beneficial effects from the use of highly caffeinated energy drinks (eg, awakening from sleepiness) and harms as adverse effects of the drinks (eg, cardiac palpitation). Likelihood of action represents the likelihood of taking actions that are perceived to be more beneficial after comparison of the benefits and harms of caffeine use. Descriptive analysis was used to quantify the relationship between their beliefs about highly caffeinated energy drinks and their use. We conducted hierarchical logistic regression to compute ORs and 95% CIs for: (1) demographic factors, (2) health threat, (3) likelihood of action and (4) cues to act. Altogether, 833 students responded to the questionnaire (effective response rate=98.0%). About 63.0% reported use of highly caffeinated energy drinks and 35.2% had used them as needed and habitually. The more susceptible the respondents perceived themselves to be to the risk of using these drinks, the less likely they were to use them (OR: 0.73, 95% CI 0.50 to 1.06). The more severe the perception of a health threat, the less that perception was associated with use (OR: 0.44, 95% CI 0.29 to 0.67). Likelihood of action was the strongest predictor of use, explaining 12.5% in use. Benefits and harms (OR: 4.43, 95% CI 2.77 to 7.09; OR: 1.86, 95% CI 1.16 to 2.99) also were significant predictors. Enhancing adolescents' perceptions of benefits and harms regarding using highly caffeinated energy drinks could be an effective way to influence the use of these drinks. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All

  5. Application of digital image processing for the generation of voxels phantoms for Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Boia, L.S.; Menezes, A.F.; Cardoso, M.A.C. [Programa de Engenharia Nuclear/COPPE (Brazil); Rosa, L.A.R. da [Instituto de Radioprotecao e Dosimetria-IRD, Av. Salvador Allende, s/no Recreio dos Bandeirantes, CP 37760, CEP 22780-160 Rio de Janeiro, RJ (Brazil); Batista, D.V.S. [Instituto de Radioprotecao e Dosimetria-IRD, Av. Salvador Allende, s/no Recreio dos Bandeirantes, CP 37760, CEP 22780-160 Rio de Janeiro, RJ (Brazil); Instituto Nacional de Cancer-Secao de Fisica Medica, Praca Cruz Vermelha, 23-Centro, 20230-130 Rio de Janeiro, RJ (Brazil); Cardoso, S.C. [Departamento de Fisica Nuclear, Instituto de Fisica, Universidade Federal do Rio de Janeiro, Bloco A-Sala 307, CP 68528, CEP 21941-972 Rio de Janeiro, RJ (Brazil); Silva, A.X., E-mail: ademir@con.ufrj.br [Programa de Engenharia Nuclear/COPPE (Brazil); Departamento de Engenharia Nuclear/Escola Politecnica, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970 Rio de Janeiro, RJ (Brazil); Facure, A. [Comissao Nacional de Energia Nuclear, R. Gal. Severiano 90, sala 409, 22294-900 Rio de Janeiro, RJ (Brazil)

    2012-01-15

    This paper presents the application of a computational methodology for optimizing the conversion of medical tomographic images in voxel anthropomorphic models for simulation of radiation transport using the MCNP code. A computational system was developed for digital image processing that compresses the information from the DICOM medical image before it is converted to the Scan2MCNP software input file for optimization of the image data. In order to validate the computational methodology, a radiosurgery treatment simulation was performed using the Alderson Rando phantom and the acquisition of DICOM images was performed. The simulation results were compared with data obtained with the BrainLab planning system. The comparison showed good agreement for three orthogonal treatment beams of {sup 60}Co gamma radiation. The percentage differences were 3.07%, 0.77% and 6.15% for axial, coronal and sagital projections, respectively. - Highlights: Black-Right-Pointing-Pointer We use a method to optimize the CT image conversion in voxel model for MCNP simulation. Black-Right-Pointing-Pointer We present a methodology to compress a DICOM image before conversion to input file. Black-Right-Pointing-Pointer To validate this study an idealized radiosurgery applied to the Alderson phantom was used.

  6. Computation of a voxelized anthropomorphic phantom from Computer Tomography slices and 3D dose distribution calculation utilizing the MCNP5 Code

    International Nuclear Information System (INIS)

    Abella, V.; Miro, R.; Juste, B.; Verdu, G.

    2008-01-01

    Full text: The purpose of this work is to obtain the voxelization of a series of tomography slices in order to provide a voxelized human phantom throughout a MatLab algorithm, and the consequent simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780 (MDS Nordion) 60 Co radiotherapy unit, using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5. The project provides as results dose mapping calculations inside the voxelized anthropomorphic phantom. Prior works have validated the cobalt therapy model utilizing a simple heterogeneous water cube-shaped phantom. The reference phantom model utilized in this work is the Zubal phantom, which consists of a group of pre-segmented CT slices of a human body. The CT slices are to be input into the Matlab program which computes the voxelization by means of two-dimensional pixel and material identification on each slice, and three-dimensional interpolation, in order to depict the phantom geometry via small cubic cells. Each slice is divided in squares with the size of the desired voxelization, and then the program searches for the pixel intensity with a predefined material at each square, making a subsequent three-dimensional interpolation. At the end of this process, the program produces a voxelized phantom in which each voxel defines the mixture of the different materials that compose it. In the case of the Zubal phantom, the voxels result in pure organ materials due to the fact that the phantom is presegmented. The output of this code follows the MCNP input deck format and is integrated in a full input model including the 60 Co radiotherapy unit. Dose rates are calculated using the MCNP5 tool FMESH, superimposed mesh tally. This feature allows to tally particles on an independent mesh over the problem geometry, and to obtain the length estimation of the particle flux, in units of particles/cm 2 (tally F4). Furthermore, the particle flux is transformed into dose by

  7. 50-year-old history of the Korean physical society

    International Nuclear Information System (INIS)

    2002-12-01

    This book introduces the root of Korean physics, the dawning of Korean physics, foundation and childhood of Korean physics society, growth of Korean physics society, revival of Korean physics society, corporation Korean physics society, leap of Korean physics society and challenges towards future. It also deals with 50-year-old history of the Korean physical society according to committees, special interest groups, branches in cities and provinces, branches in universities, laboratories, society bureau, and commemoration business to celebrate 50th anniversary.

  8. Korean Unification: Opportunities and Threats

    National Research Council Canada - National Science Library

    Bundy, Richard B

    1992-01-01

    .... in addition, they agreed to support the Korean peninsula as a nuclear free zone. The two countries have existed in fact since the partition of the peninsula after the allied victory over Japan In 1945...

  9. A voxel-based approach to gray matter asymmetries.

    Science.gov (United States)

    Luders, E; Gaser, C; Jancke, L; Schlaug, G

    2004-06-01

    Voxel-based morphometry (VBM) was used to analyze gray matter (GM) asymmetries in a large sample (n = 60) of male and female professional musicians with and without absolute pitch (AP). We chose to examine these particular groups because previous studies using traditional region-of-interest (ROI) analyses have shown differences in hemispheric asymmetry related to AP and gender. Voxel-based methods may have advantages over traditional ROI-based methods since the analysis can be performed across the whole brain with minimal user bias. After determining that the VBM method was sufficiently sensitive for the detection of differences in GM asymmetries between groups, we found that male AP musicians were more leftward lateralized in the anterior region of the planum temporale (PT) than male non-AP musicians. This confirmed the results of previous studies using ROI-based methods that showed an association between PT asymmetry and the AP phenotype. We further observed that male non-AP musicians revealed an increased leftward GM asymmetry in the postcentral gyrus compared to female non-AP musicians, again corroborating results of a previously published study using ROI-based methods. By analyzing hemispheric GM differences across our entire sample, we were able to partially confirm findings of previous studies using traditional morphometric techniques, as well as more recent, voxel-based analyses. In addition, we found some unusually pronounced GM asymmetries in our musician sample not previously detected in subjects unselected for musical training. Since we were able to validate gender- and AP-related brain asymmetries previously described using traditional ROI-based morphometric techniques, the results of our analyses support the use of VBM for examinations of GM asymmetries.

  10. Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

    International Nuclear Information System (INIS)

    Hoseinian-Azghadi, E.; Rafat-Motavalli, L.; Miri-Hakimabad, H.

    2014-01-01

    This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for 131 Iodine, 123 Iodine and 99m Tc incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0–55% was made, and the effect of various techniques for administration of 99m Tc on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source–target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for 123 I and 99m Tc. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5–55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for 99m Tc incorporation. (author)

  11. Trace of Korean mechanical industry

    International Nuclear Information System (INIS)

    1996-12-01

    This book reports 50 years of Korean mechanical engineers, which includes birth and history, remembrance and future of Korean society of mechanical engineers, current situation and development of mechanical industry such as national industry and 50 years of mechanical industry, track, airline industry, ship and marine engine, a precision instrument, cutting work, casting, welding, plastic working freeze and air handling nuclear power and textile machinery.

  12. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla

    OpenAIRE

    Koush, Yury; Elliott, Mark A.; Mathiak, Klaus

    2011-01-01

    Echo-planar imaging (EPI) in fMRI is regularly used to reveal BOLD activation in presubscribed regions of interest (ROI). The response is mediated by relative changes in T2* which appear as changes in the image pixel intensities. We have proposed an application of functional single-voxel proton spectroscopy (fSVPS) for real-time studies at ultra-high MR field which can be comparable to the EPI BOLD fMRI technique. A spin-echo SVPS protocol without water suppression was acquired with 310 repet...

  13. Development of modified voxel phantoms for the numerical dosimetric reconstruction of radiological accidents involving external sources: implementation in SESAME tool.

    Science.gov (United States)

    Courageot, Estelle; Sayah, Rima; Huet, Christelle

    2010-05-07

    Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.

  14. Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom

    International Nuclear Information System (INIS)

    Evans, Jeffrey F.; Blue, Thomas E.; Gupta, Nilendu

    2001-01-01

    The purpose of this article is to demonstrate the viability of using a high-resolution 3-D head phantom in Monte Carlo N-Particle (MCNP) for boron neutron capture therapy (BNCT) structure dosimetry. This work describes a high-resolution voxel-based model of a human head and its use for calculating absorbed doses to the structures of the brain. The Zubal head phantom is a 3-D model of a human head that can be displayed and manipulated on a computer. Several changes were made to the original head phantom which now contains over 29 critical structures of the brain and head. The modified phantom is a 85x109x120 lattice of voxels, where each voxel is 2.2x2.2x1.4 mm 3 . This model was translated into MCNP lattice format. As a proof of principle study, two MCNP absorbed dose calculations were made (left and right lateral irradiations) using a uniformly distributed neutron disk source with an 1/E energy spectrum. Additionally, the results of these two calculations were combined to estimate the absorbed doses from a bilateral irradiation. Radiobiologically equivalent (RBE) doses were calculated for all structures and were normalized to 12.8 Gy-Eq. For a left lateral irradiation, the left motor cortex receives the limiting RBE dose. For a bilateral irradiation, the insula cortices receive the limiting dose. Among the nonencephalic structures, the parotid glands receive RBE doses that were within 15% of the limiting dose

  15. Regional gray matter abnormalities in patients with schizophrenia determined with optimized voxel-based morphometry

    Science.gov (United States)

    Guo, XiaoJuan; Yao, Li; Jin, Zhen; Chen, Kewei

    2006-03-01

    This study examined regional gray matter abnormalities across the whole brain in 19 patients with schizophrenia (12 males and 7 females), comparing with 11 normal volunteers (7 males and 4 females). The customized brain templates were created in order to improve spatial normalization and segmentation. Then automated preprocessing of magnetic resonance imaging (MRI) data was conducted using optimized voxel-based morphometry (VBM). The statistical voxel based analysis was implemented in terms of two-sample t-test model. Compared with normal controls, regional gray matter concentration in patients with schizophrenia was significantly reduced in the bilateral superior temporal gyrus, bilateral middle frontal and inferior frontal gyrus, right insula, precentral and parahippocampal areas, left thalamus and hypothalamus as well as, however, significant increases in gray matter concentration were not observed across the whole brain in the patients. This study confirms and extends some earlier findings on gray matter abnormalities in schizophrenic patients. Previous behavior and fMRI researches on schizophrenia have suggested that cognitive capacity decreased and self-conscious weakened in schizophrenic patients. These regional gray matter abnormalities determined through structural MRI with optimized VBM may be potential anatomic underpinnings of schizophrenia.

  16. Empirical Bayesian estimation in graphical analysis: a voxel-based approach for the determination of the volume of distribution in PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Zanderigo, Francesca [Department of Molecular Imaging and Neuropathology, New York State Psychiatric Institute, New York, NY (United States)], E-mail: francesca.zanderigo@gmail.com; Ogden, R. Todd [Department of Molecular Imaging and Neuropathology, New York State Psychiatric Institute, New York, NY (United States); Department of Psychiatry, College of Physicians and Surgeons, Columbia University, New York, NY (United States); Department of Biostatistics, Mailman School of Public Health, Columbia University, New York, NY (United States); Bertoldo, Alessandra; Cobelli, Claudio [Department of Information Engineering, University of Padova, Padova (Italy); Mann, J. John; Parsey, Ramin V. [Department of Molecular Imaging and Neuropathology, New York State Psychiatric Institute, New York, NY (United States); Department of Psychiatry, College of Physicians and Surgeons, Columbia University, New York, NY (United States)

    2010-05-15

    Introduction: Total volume of distribution (V{sub T}) determined by graphical analysis (GA) of PET data suffers from a noise-dependent bias. Likelihood estimation in GA (LEGA) eliminates this bias at the region of interest (ROI) level, but at voxel noise levels, the variance of estimators is high, yielding noisy images. We hypothesized that incorporating LEGA V{sub T} estimation in a Bayesian framework would shrink estimators towards prior means, reducing variability and producing meaningful and useful voxel images. Methods: Empirical Bayesian estimation in GA (EBEGA) determines prior distributions using a two-step k-means clustering of voxel activity. Results obtained on eight [{sup 11}C]-DASB studies are compared with estimators computed by ROI-based LEGA. Results: EBEGA reproduces the results obtained by ROI LEGA while providing low-variability V{sub T} images. Correlation coefficients between average EBEGA V{sub T} and corresponding ROI LEGA V{sub T} range from 0.963 to 0.994. Conclusions: EBEGA is a fully automatic and general approach that can be applied to voxel-level V{sub T} image creation and to any modeling strategy to reduce voxel-level estimation variability without prefiltering of the PET data.

  17. Mister Voxel: 3D internal dosimetry software for nuclear medicine

    International Nuclear Information System (INIS)

    McKay, E.

    1998-01-01

    Full text: Calculation of individual internal dosimetry in nuclear medicine is a complex, multi-stage process. Most often, calculations are biased on the MIRD methodology, which assumes uniform distribution of cumulated activity inside a set of mathematically described internal organs. The MIRD 'reference man' geometry is highly simplified and the dosimetry estimates generated by this method were originally only intended to predict the average dose expected in an exposed population. We have developed a software package for the Macintosh computer ('Mister Voxel') that uses a fast Fourier transform to calculate the 3D distribution of absorbed dose by convolving a 3D dose kernel with a 3D distribution of cumulated activity. This makes it possible to generate dose volume histograms and isodose contours for organs or tumours treated with radiopharmaceuticals, a task not possible using the MIRD technique. In addition to providing 3D convolution, Mister Voxel performs basic image processing functions (image math, filters, cut and paste) and provides a collection of painting tools and simple morphological operators to facilitate the delineation of regions of interest (ROIs) along anatomical boundaries. The package also includes an image registration module with tools for automated or manual registration of 3D data sets. The structure of the package allows ROIs drawn on CT or MRI data to be easily transferred to registered SPECT data. Dose kernels are implemented by plug-in code modules, allowing the user to extend the system's capabilities if required. File import and export capabilities are also extensible

  18. Factors related to job satisfaction among South Korean dentists.

    Science.gov (United States)

    Jeong, Seong-Hwa; Chung, Jae-Kyun; Choi, Youn-Hee; Sohn, Woosung; Song, Keun-Bae

    2006-12-01

    The purposes of this study were to investigate the level and distribution of job satisfaction and to explore work environment factors associated with job satisfaction of South Korean dentists. A stratified systematic random sample of 1029 dentists was selected from the 10 357 registered dentists in the Korean Dental Association. They were surveyed via a self-administered mail questionnaire. Job satisfaction was measured by a modified version of the Dentist Satisfaction Survey. The response rate was 62.2%. The mean score of overall job satisfaction among South Korean dentists was 3.2 out of 5. In terms of work environment factors, the most satisfying aspect was patient relations (3.7) and the least satisfying aspect was personal time (2.8). Multiple regression analysis identified a model including patient relations, perception of income, personal time, staff, and specialty training that accounted for 35% of variation in overall job satisfaction. The majority of the variance was explained by patient relations. This study suggests that patient relations, perception of income, personal time, staff, and specialty training are important work environment factors for job satisfaction among South Korean dentists. The findings of this study will be helpful to policy makers to design plans to increase the level of job satisfaction among South Korean dentists.

  19. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla

    Directory of Open Access Journals (Sweden)

    Mark A. Elliott

    2011-09-01

    Full Text Available Echo-planar imaging (EPI in fMRI is regularly used to reveal BOLD activation in presubscribed regions of interest (ROI. The response is mediated by relative changes in T2* which appear as changes in the image pixel intensities. We have proposed an application of functional single-voxel proton spectroscopy (fSVPS for real-time studies at ultra-high MR field which can be comparable to the EPI BOLD fMRI technique. A spin-echo SVPS protocol without water suppression was acquired with 310 repetitions on a 7T Siemens MR scanner (TE/TR = 20/1000 ms, flip angle α = 90°, voxel size 10 × 10 × 10 mm3. Transmitter reference voltage was optimized for the voxel location. Spectral processing of the water signal free induction decay (FID using log-linear regression was used to estimate the T2* change between rest and activation of a functional task. The FID spectrum was filtered with a Gaussian window around the water peak, and log-linear regression was optimized for the particular ROI by adoption of the linearization length. The spectroscopic voxel was positioned on an ROI defined from a real-time fMRI EPI BOLD localizer. Additional online signal processing algorithms performed signal drift removal (exponential moving average, despiking and low-pass filtering (modified Kalman filter and, finally, the dynamic feedback signal normalization. Two functional tasks were used to estimate the sensitivity of the SVPS method compared to BOLD signal changes, namely the primary motor cortex (PMC, left hand finger tapping and visual cortex (VC, blinking checkerboard. Four healthy volunteers performed these tasks and an additional session using real-time signal feedback modulating their activation level of the PMC. Results show that single voxel spectroscopy is able to provide a good and reliable estimation of the BOLD signal changes. Small data size and FID signal processing instead of processing entire brain volumes as well as more information revealed from the

  20. Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Fox, Christopher; Romeijn, H. Edwin; Dempsey, James F.

    2006-01-01

    We present work on combining three algorithms to improve ray-tracing efficiency in radiation therapy dose computation. The three algorithms include: An improved point-in-polygon algorithm, incremental voxel ray tracing algorithm, and stereographic projection of beamlets for voxel truncation. The point-in-polygon and incremental voxel ray-tracing algorithms have been used in computer graphics and nuclear medicine applications while the stereographic projection algorithm was developed by our group. These algorithms demonstrate significant improvements over the current standard algorithms in peer reviewed literature, i.e., the polygon and voxel ray-tracing algorithms of Siddon for voxel classification (point-in-polygon testing) and dose computation, respectively, and radius testing for voxel truncation. The presented polygon ray-tracing technique was tested on 10 intensity modulated radiation therapy (IMRT) treatment planning cases that required the classification of between 0.58 and 2.0 million voxels on a 2.5 mm isotropic dose grid into 1-4 targets and 5-14 structures represented as extruded polygons (a.k.a. Siddon prisms). Incremental voxel ray tracing and voxel truncation employing virtual stereographic projection was tested on the same IMRT treatment planning cases where voxel dose was required for 230-2400 beamlets using a finite-size pencil-beam algorithm. Between a 100 and 360 fold cpu time improvement over Siddon's method was observed for the polygon ray-tracing algorithm to perform classification of voxels for target and structure membership. Between a 2.6 and 3.1 fold reduction in cpu time over current algorithms was found for the implementation of incremental ray tracing. Additionally, voxel truncation via stereographic projection was observed to be 11-25 times faster than the radial-testing beamlet extent approach and was further improved 1.7-2.0 fold through point-classification using the method of translation over the cross product technique

  1. Catalogue of Korean manuscripts and rare books

    DEFF Research Database (Denmark)

    Lerbæk Pedersen, Bent

    2014-01-01

    Catalogue of Korean manuscripts and rare books in The Royal Library, Copenhagen and the National Museum of Denmark......Catalogue of Korean manuscripts and rare books in The Royal Library, Copenhagen and the National Museum of Denmark...

  2. Quantifying Standing Dead Tree Volume and Structural Loss with Voxelized Terrestrial Lidar Data

    Science.gov (United States)

    Popescu, S. C.; Putman, E.

    2017-12-01

    Standing dead trees (SDTs) are an important forest component and impact a variety of ecosystem processes, yet the carbon pool dynamics of SDTs are poorly constrained in terrestrial carbon cycling models. The ability to model wood decay and carbon cycling in relation to detectable changes in tree structure and volume over time would greatly improve such models. The overall objective of this study was to provide automated aboveground volume estimates of SDTs and automated procedures to detect, quantify, and characterize structural losses over time with terrestrial lidar data. The specific objectives of this study were: 1) develop an automated SDT volume estimation algorithm providing accurate volume estimates for trees scanned in dense forests; 2) develop an automated change detection methodology to accurately detect and quantify SDT structural loss between subsequent terrestrial lidar observations; and 3) characterize the structural loss rates of pine and oak SDTs in southeastern Texas. A voxel-based volume estimation algorithm, "TreeVolX", was developed and incorporates several methods designed to robustly process point clouds of varying quality levels. The algorithm operates on horizontal voxel slices by segmenting the slice into distinct branch or stem sections then applying an adaptive contour interpolation and interior filling process to create solid reconstructed tree models (RTMs). TreeVolX estimated large and small branch volume with an RMSE of 7.3% and 13.8%, respectively. A voxel-based change detection methodology was developed to accurately detect and quantify structural losses and incorporated several methods to mitigate the challenges presented by shifting tree and branch positions as SDT decay progresses. The volume and structural loss of 29 SDTs, composed of Pinus taeda and Quercus stellata, were successfully estimated using multitemporal terrestrial lidar observations over elapsed times ranging from 71 - 753 days. Pine and oak structural loss rates

  3. Health Inequalities Among Korean Employees

    Directory of Open Access Journals (Sweden)

    Eunsuk Choi

    2017-12-01

    Full Text Available Background: Social status might be a determinant of occupational health inequalities. This study analyzed the effects of social status on both work environments and health outcomes. Methods: The study sample consisted of 27,598 wage employees aged 15 years and older from among the Korean Working Condition Survey participants in 2011. Work environments included atypical work, physical risks, ergonomic risks, work demands, work autonomy, social supports, and job rewards. Health outcomes comprised general health, health and safety at risk because of work, the World Health Organization-5 Well-being Index, work-related musculoskeletal disease, and work-related injury. Multivariable logistic-regression models were used to identify the associations between social status and work environments and health outcomes. Results: Employees in the demographically vulnerable group had lower occupational status compared with their counterparts. Low social status was largely related to adverse work environments. Especially, precarious employment and manual labor occupation were associated with both adverse work environments and poor health outcomes. Conclusion: Precarious and manual workers should take precedence in occupational health equity policies and interventions. Their cumulative vulnerability, which is connected to demographics, occupational status, adverse work environments, or poor health outcomes, can be improved through a multilevel approach such as labor market, organizations, and individual goals. Keywords: employee health, health equity, social status

  4. WE-D-BRE-06: Quantification of Dose-Response for High Grade Esophagtis Patients Using a Novel Voxel-To-Voxel Method

    International Nuclear Information System (INIS)

    Niedzielski, J; Martel, M; Tucker, S; Gomez, D; Court, L; Yang, J; Briere, T

    2014-01-01

    Purpose: Radiation induces an inflammatory response in the esophagus, discernible on CT studies. This work objectively quantifies the voxel esophageal radiation-response for patients with acute esophagitis. This knowledge is an important first-step towards predicting the effect of complex dose distributions on patient esophagitis symptoms. Methods: A previously validated voxel-based methodology of quantifying radiation esophagitis severity was used to identify the voxel dose-response for 18 NSCLC patients with severe esophagitis (CTCAE grading criteria, grade2 or higher). The response is quantified as percent voxel volume change for a given dose. During treatment (6–8 weeks), patients had weekly 4DCT studies and esophagitis scoring. Planning CT esophageal contours were deformed to each weekly CT using a demons DIR algorithm. An algorithm using the Jacobian Map from the DIR of the planning CT to all weekly CTs was used to quantify voxel-volume change, along with corresponding delivered voxel dose, to the planning voxel. Dose for each voxel for each time-point was calculated on each previous weekly CT image, and accumulated using DIR. Thus, for each voxel, the volume-change and delivered dose was calculated for each time-point. The data was binned according to when the volume-change first increased by a threshold volume (10%–100%, in 10% increments), and the average delivered dose calculated for each bin. Results: The average dose resulting in a voxel volume increase of 10–100% was 21.6 to 45.9Gy, respectively. The mean population dose to give a 50% volume increase was 36.3±4.4Gy, (range:29.8 to 43.5Gy). The average week of 50% response was 4.1 (range:4.9 to 2.8 weeks). All 18 patients showed similar dose to first response curves, showing a common trend in the initial inflammatoryresponse. Conclusion: We extracted the dose-response curve of the esophagus on a voxel-to-voxel level. This may be useful for estimating the esophagus response (and patient symptoms

  5. Korean Culture and Autism Spectrum Disorders

    Science.gov (United States)

    Kang-Yi, Christina D.; Grinker, Roy R.; Mandell, David S.

    2013-01-01

    This paper reviews the literature on early child development among Koreans, with a focus on autism spectrum disorders (ASD). The literature review of 951 abstracts in English, 101 abstracts in Korean and 27 full articles published from 1994 to 2011 was performed to understand the presentation of and response to ASD in Korean culture. Based on…

  6. Analysis of multiplex gene expression maps obtained by voxelation.

    Science.gov (United States)

    An, Li; Xie, Hongbo; Chin, Mark H; Obradovic, Zoran; Smith, Desmond J; Megalooikonomou, Vasileios

    2009-04-29

    Gene expression signatures in the mammalian brain hold the key to understanding neural development and neurological disease. Researchers have previously used voxelation in combination with microarrays for acquisition of genome-wide atlases of expression patterns in the mouse brain. On the other hand, some work has been performed on studying gene functions, without taking into account the location information of a gene's expression in a mouse brain. In this paper, we present an approach for identifying the relation between gene expression maps obtained by voxelation and gene functions. To analyze the dataset, we chose typical genes as queries and aimed at discovering similar gene groups. Gene similarity was determined by using the wavelet features extracted from the left and right hemispheres averaged gene expression maps, and by the Euclidean distance between each pair of feature vectors. We also performed a multiple clustering approach on the gene expression maps, combined with hierarchical clustering. Among each group of similar genes and clusters, the gene function similarity was measured by calculating the average gene function distances in the gene ontology structure. By applying our methodology to find similar genes to certain target genes we were able to improve our understanding of gene expression patterns and gene functions. By applying the clustering analysis method, we obtained significant clusters, which have both very similar gene expression maps and very similar gene functions respectively to their corresponding gene ontologies. The cellular component ontology resulted in prominent clusters expressed in cortex and corpus callosum. The molecular function ontology gave prominent clusters in cortex, corpus callosum and hypothalamus. The biological process ontology resulted in clusters in cortex, hypothalamus and choroid plexus. Clusters from all three ontologies combined were most prominently expressed in cortex and corpus callosum. The experimental

  7. Analysis of multiplex gene expression maps obtained by voxelation

    Directory of Open Access Journals (Sweden)

    Smith Desmond J

    2009-04-01

    Full Text Available Abstract Background Gene expression signatures in the mammalian brain hold the key to understanding neural development and neurological disease. Researchers have previously used voxelation in combination with microarrays for acquisition of genome-wide atlases of expression patterns in the mouse brain. On the other hand, some work has been performed on studying gene functions, without taking into account the location information of a gene's expression in a mouse brain. In this paper, we present an approach for identifying the relation between gene expression maps obtained by voxelation and gene functions. Results To analyze the dataset, we chose typical genes as queries and aimed at discovering similar gene groups. Gene similarity was determined by using the wavelet features extracted from the left and right hemispheres averaged gene expression maps, and by the Euclidean distance between each pair of feature vectors. We also performed a multiple clustering approach on the gene expression maps, combined with hierarchical clustering. Among each group of similar genes and clusters, the gene function similarity was measured by calculating the average gene function distances in the gene ontology structure. By applying our methodology to find similar genes to certain target genes we were able to improve our understanding of gene expression patterns and gene functions. By applying the clustering analysis method, we obtained significant clusters, which have both very similar gene expression maps and very similar gene functions respectively to their corresponding gene ontologies. The cellular component ontology resulted in prominent clusters expressed in cortex and corpus callosum. The molecular function ontology gave prominent clusters in cortex, corpus callosum and hypothalamus. The biological process ontology resulted in clusters in cortex, hypothalamus and choroid plexus. Clusters from all three ontologies combined were most prominently expressed in

  8. The effects of perceived leisure constraints among Korean university students

    Science.gov (United States)

    Sae-Sook Oh; Sei-Yi Oh; Linda L. Caldwell

    2002-01-01

    This study is based on Crawford, Jackson, and Godbey's model of leisure constraints (1991), and examines the relationships between the influences of perceived constraints, frequency of participation, and health status in the context of leisure-time outdoor activities. The study was based on a sample of 234 Korean university students. This study provides further...

  9. Connecting horizon pixels and interior voxels of a black hole

    International Nuclear Information System (INIS)

    Nicolini, Piero; Singleton, Douglas

    2014-01-01

    In this paper we discuss to what extent one can infer details of the interior structure of a black hole based on its horizon. Recalling that black hole thermal properties are connected to the non-classical nature of gravity, we circumvent the restrictions of the no-hair theorem by postulating that the black hole interior is singularity free due to violations of the usual energy conditions. Further these conditions allow one to establish a one-to-one, holographic projection between Planckian areal “bits” on the horizon and “voxels”, representing the gravitational degrees of freedom in the black hole interior. We illustrate the repercussions of this idea by discussing an example of the black hole interior consisting of a de Sitter core postulated to arise from the local graviton quantum vacuum energy. It is shown that the black hole entropy can emerge as the statistical entropy of a gas of voxels

  10. Effects of image distortion correction on voxel-based morphometry

    International Nuclear Information System (INIS)

    Goto, Masami; Abe, Osamu; Kabasawa, Hiroyuki

    2012-01-01

    We aimed to show that correcting image distortion significantly affects brain volumetry using voxel-based morphometry (VBM) and to assess whether the processing of distortion correction reduces system dependency. We obtained contiguous sagittal T 1 -weighted images of the brain from 22 healthy participants using 1.5- and 3-tesla magnetic resonance (MR) scanners, preprocessed images using Statistical Parametric Mapping 5, and tested the relation between distortion correction and brain volume using VBM. Local brain volume significantly increased or decreased on corrected images compared with uncorrected images. In addition, the method used to correct image distortion for gradient nonlinearity produced fewer volumetric errors from MR system variation. This is the first VBM study to show more precise volumetry using VBM with corrected images. These results indicate that multi-scanner or multi-site imaging trials require correction for distortion induced by gradient nonlinearity. (author)

  11. Korean Version of Child Perceptions Questionnaire and Dental Caries among Korean Children

    Science.gov (United States)

    Shin, Hye-Sun; Han, Dong-Hun; Shin, Myung-Seop; Lee, Hyun-Jin; Kim, Mi-Sun; Kim, Hyun-Duck

    2015-01-01

    Although dental caries has been a major oral health problem for children, the association between dental caries and oral health related quality of life has been still controversial. This study aims to evaluate the association between the Korean version of the Child Perceptions Questionnaire (K-CPQ) and dental caries among Korean children. Eight hundred one school children aged 8 to 14 years participated in this study. After the K-CPQ was validated we performed an association study. The K-CPQ was self-reported. Dental caries were evaluated by dentists using the World Health Organization Index. Correlation analyses (intraclass correlation coefficient, Cronbach’s alpha and Pearson’s correlation coefficient [r]) and linear regression models (partial r) including age, gender and type of school were applied. Untreated deciduous dental caries was associated with the K-CPQ8-10 overall score (partial r = 0.15, P caries (FT) was associated with the K-CPQ11-14 overall domain (partial r = 0.14, P = 0.002) as well as with the oral symptoms domain (partial r = 0.16, P = 0.001). This association was highlighted among public school children. Our data indicate that K-CPQ was independently associated with dental caries. The K-CPQ could be a practical tool to evaluate the subjective oral health among Korean children aged 8 to 14. PMID:25675410

  12. Management of Sport Injuries with Korean Medicine: A Survey of Korean National Volleyball Team

    Directory of Open Access Journals (Sweden)

    Changsop Yang

    2016-01-01

    Full Text Available The purpose of this study was to report the current state of Korean medicine (KM treatment on sports injury by implementing survey with volleyball team medical doctors participating in 2013-2014 season. Six KM doctors completed a questionnaire that includes injury parameters: type, location, situation, and pain scores. We collected 166 injury cases from 94 Korean male and female national volleyball players. Knee (25.9%, low back (13.3%, elbow, and ankle (8.4% injuries were most common. Joint (41.6% and muscle (30.7% were major injured tissues. KM team medical doctors utilized acupuncture (40.4%, chuna manual therapy (16.0%, physical therapy (15.2%, taping (9.0%, and cupping (7.8% to treat volleyball injuries. Any types of medications were used infrequently. Additional physical and exercise therapy were preferred after receiving acupuncture (both 46.9%. This study presented the preliminary injury profile of Korean elite volleyball players. Injury and treatment parameters could be useful to build advanced KM model in sport medicine.

  13. Korean letter handwritten recognition using deep convolutional neural network on android platform

    Science.gov (United States)

    Purnamawati, S.; Rachmawati, D.; Lumanauw, G.; Rahmat, R. F.; Taqyuddin, R.

    2018-03-01

    Currently, popularity of Korean culture attracts many people to learn everything about Korea, particularly its language. To acquire Korean Language, every single learner needs to be able to understand Korean non-Latin character. A digital approach needs to be carried out in order to make Korean learning process easier. This study is done by using Deep Convolutional Neural Network (DCNN). DCNN performs the recognition process on the image based on the model that has been trained such as Inception-v3 Model. Subsequently, re-training process using transfer learning technique with the trained and re-trained value of model is carried though in order to develop a new model with a better performance without any specific systemic errors. The testing accuracy of this research results in 86,9%.

  14. Prostate dose calculations for permanent implants using the MCNPX code and the Voxels phantom MAX

    Energy Technology Data Exchange (ETDEWEB)

    Reis Junior, Juraci Passos dos; Silva, Ademir Xavier da, E-mail: jjunior@con.ufrj.b, E-mail: Ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Facure, Alessandro N.S., E-mail: facure@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2010-07-01

    This paper presents the modeling of 80, 88 and 100 of {sup 125}I seeds, punctual and volumetric inserted into the phantom spherical volume representing the prostate and prostate phantom voxels MAX. Starting values of minimum and maximum activity, 0.27 mCi and 0.38 mCi, respectively, were simulated in the Monte Carlo code MCNPX in order to determine whether the final dose, according to the integration of the equation of decay at time t = 0 to t = {infinity} corresponds to the default value set by the AAPM 64 which is 144 Gy. The results showed that consider sources results in doses exceeding the percentage discrepancy of the default value of 200%, while volumetric consider sources result in doses close to 144 Gy. (author)

  15. White matter impairments in autism, evidence from voxel-based morphometry and diffusion tensor imaging.

    Science.gov (United States)

    Ke, Xiaoyan; Tang, Tianyu; Hong, Shanshan; Hang, Yueyue; Zou, Bing; Li, Huiguo; Zhou, Zhenyu; Ruan, Zongcai; Lu, Zuhong; Tao, Guotai; Liu, Yijun

    2009-04-10

    This study explored white matter abnormalities in a group of Chinese children with high functioning autism (HFA). Twelve male children with HFA and ten matched typically developing children underwent diffusion tensor imaging (DTI) as well three-dimensional T1-weighted MRI for voxel-based morphometry (VBM). We found a significant decrease of the white matter density in the right frontal lobe, left parietal lobe and right anterior cingulate and a significant increase in the right frontal lobe, left parietal lobe and left cingulate gyrus in the HFA group compared with the control group. The HFA group also had decreased FA in the frontal lobe and left temporal lobe. By combining DT-MRI FA and MRI volumetric analyses based on the VBM model, the results showed consistent white matter abnormalities in a group of Chinese children with HFA.

  16. Prostate dose calculations for permanent implants using the MCNPX code and the Voxels phantom MAX

    International Nuclear Information System (INIS)

    Reis Junior, Juraci Passos dos; Silva, Ademir Xavier da

    2010-01-01

    This paper presents the modeling of 80, 88 and 100 of 125 I seeds, punctual and volumetric inserted into the phantom spherical volume representing the prostate and prostate phantom voxels MAX. Starting values of minimum and maximum activity, 0.27 mCi and 0.38 mCi, respectively, were simulated in the Monte Carlo code MCNPX in order to determine whether the final dose, according to the integration of the equation of decay at time t = 0 to t = ∞ corresponds to the default value set by the AAPM 64 which is 144 Gy. The results showed that consider sources results in doses exceeding the percentage discrepancy of the default value of 200%, while volumetric consider sources result in doses close to 144 Gy. (author)

  17. Preface to the Korean edition (in Korean)

    DEFF Research Database (Denmark)

    Jakobsen, Peter Viggo

    2015-01-01

    It goes without saying that one cannot simply copy the Nordic model and experiences. Each nation has to develop its own approach in keeping with its own strategic culture. To be sustainable a national approach to peace operations has to appeal to both hearts and minds of the nation in question...

  18. A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP).

    Science.gov (United States)

    Bitar, A; Lisbona, A; Thedrez, P; Sai Maurel, C; Le Forestier, D; Barbet, J; Bardies, M

    2007-02-21

    Murine models are useful for targeted radiotherapy pre-clinical experiments. These models can help to assess the potential interest of new radiopharmaceuticals. In this study, we developed a voxel-based mouse for dosimetric estimates. A female nude mouse (30 g) was frozen and cut into slices. High-resolution digital photographs were taken directly on the frozen block after each section. Images were segmented manually. Monoenergetic photon or electron sources were simulated using the MCNP4c2 Monte Carlo code for each source organ, in order to give tables of S-factors (in Gy Bq-1 s-1) for all target organs. Results obtained from monoenergetic particles were then used to generate S-factors for several radionuclides of potential interest in targeted radiotherapy. Thirteen source and 25 target regions were considered in this study. For each source region, 16 photon and 16 electron energies were simulated. Absorbed fractions, specific absorbed fractions and S-factors were calculated for 16 radionuclides of interest for targeted radiotherapy. The results obtained generally agree well with data published previously. For electron energies ranging from 0.1 to 2.5 MeV, the self-absorbed fraction varies from 0.98 to 0.376 for the liver, and from 0.89 to 0.04 for the thyroid. Electrons cannot be considered as 'non-penetrating' radiation for energies above 0.5 MeV for mouse organs. This observation can be generalized to radionuclides: for example, the beta self-absorbed fraction for the thyroid was 0.616 for I-131; absorbed fractions for Y-90 for left kidney-to-left kidney and for left kidney-to-spleen were 0.486 and 0.058, respectively. Our voxel-based mouse allowed us to generate a dosimetric database for use in preclinical targeted radiotherapy experiments.

  19. Development of the voxel computational phantoms of pediatric patients and their application to organ dose assessment

    Science.gov (United States)

    Lee, Choonik

    A series of realistic voxel computational phantoms of pediatric patients were developed and then used for the radiation risk assessment for various exposure scenarios. The high-resolution computed tomographic images of live patients were utilized for the development of the five voxel phantoms of pediatric patients, 9-month male, 4-year female, 8-year female, 11-year male, and 14-year male. The phantoms were first developed as head and torso phantoms and then extended into whole body phantoms by utilizing computed tomographic images of a healthy adult volunteer. The whole body phantom series was modified to have the same anthropometrics with the most recent reference data reported by the international commission on radiological protection. The phantoms, named as the University of Florida series B, are the first complete set of the pediatric voxel phantoms having reference organ masses and total heights. As part of the dosimetry study, the investigation on skeletal tissue dosimetry methods was performed for better understanding of the radiation dose to the active bone marrow and bone endosteum. All of the currently available methodologies were inter-compared and benchmarked with the paired-image radiation transport model. The dosimetric characteristics of the phantoms were investigated by using Monte Carlo simulation of the broad parallel beams of external phantom in anterior-posterior, posterior-anterior, left lateral, right lateral, rotational, and isotropic angles. Organ dose conversion coefficients were calculated for extensive photon energies and compared with the conventional stylized pediatric phantoms of Oak Ridge National Laboratory. The multi-slice helical computed tomography exams were simulated using Monte Carlo simulation code for various exams protocols, head, chest, abdomen, pelvis, and chest-abdomen-pelvis studies. Results have found realistic estimates of the effective doses for frequently used protocols in pediatric radiology. The results were very

  20. Computational voxel phantom, associated to anthropometric and anthropomorphic real phantom for dosimetry in human male pelvis radiotherapy; Fantoma computacional de voxel, associado a fantoma real antropomorfico antropometrico, para dosimetria em radioterapia de pelve masculina

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleuza Helena Teixeira; Campos, Tarcisio Passos Ribeiro de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg.br

    2005-07-01

    This paper addresses a computational model of voxels through MCNP5 Code and the experimental development of an anthropometric and anthropomorphic phantom for dosimetry in human male pelvis brachytherapy focusing prostatic tumors. For elaboration of the computational model of the human male pelvis, anatomical section images from the Visible Man Project were applied. Such selected and digital images were associated to a numeric representation, one for each section. Such computational representation of the anatomical sections was transformed into a bi-dimensional mesh of equivalent tissue. The group of bidimensional meshes was concatenated forming the three-dimensional model of voxels to be used by the MCNP5 code. In association to the anatomical information, data from the density and chemical composition of the basic elements, representatives of the organs and involved tissues, were setup in a material database for the MCNP-5. The model will be applied for dosimetric evaluations in situations of irradiation of the human masculine pelvis. Such 3D model of voxel is associated to the code of transport of particles MCNP5, allowing future simulations. It was also developed the construction of human masculine pelvis phantom, based on anthropometric and anthropomorphic dates and in the use of representative equivalent tissues of the skin, fatty, muscular and glandular tissue, as well as the bony structure.This part of work was developed in stages, being built the bony cast first, later the muscular structures and internal organs. They were then jointly mounted and inserted in the skin cast. The representative component of the fatty tissue was incorporate and accomplished the final retouchings in the skin. The final result represents the development of two important essential tools for elaboration of computational and experimental dosimetry. Thus, it is possible its use in calibrations of pre-existent protocols in radiotherapy, as well as for tests of new protocols, besides

  1. Combining voxel-based morphometry and diffusion tensor imaging to detect age-related brain changes.

    Science.gov (United States)

    Lehmbeck, Jan T; Brassen, Stefanie; Weber-Fahr, Wolfgang; Braus, Dieter F

    2006-04-03

    The present study combined optimized voxel-based morphometry and diffusion tensor imaging to detect age-related brain changes. We compared grey matter density maps (grey matter voxel-based morphometry) and white matter fractional anisotropy maps (diffusion tensor imaging-voxel-based morphometry) between two groups of 17 younger and 17 older women. Older women exhibited reduced white matter fractional anisotropy as well as decreased grey matter density most prominently in the frontal, limbic, parietal and temporal lobes. A discriminant analysis identified four frontal and limbic grey and white matter areas that separated the two groups most effectively. We conclude that grey matter voxel-based morphometry and diffusion tensor imaging voxel-based morphometry are well suited for the detection of age-related changes and their combination provides high accuracy when detecting the neural correlates of aging.

  2. Aesthetics of Korean foods: The symbol of Korean culture

    Directory of Open Access Journals (Sweden)

    Hae-Kyung Chung

    2016-09-01

    Full Text Available Advances in transportation and communication have broken down critical barriers within the global economy, pushing us towards a more unified world. In keeping with this trend, processes of communication, transportation, and production are becoming increasingly standardized, mechanized, and automated. Yet as this global era of uniformity progresses, people and individuals will inevitably encounter identity confusion. Numerous individuals, ethnicities, nationalities, and countries around the world are working to counteract such identity confusion. As globalization progresses, groups and nationalities that fail to preserve their identities will dwindle and become absorbed by stronger entities. Therefore, many societies are investing great efforts into rediscovering and revamping their indigenous traditions, cultures, and customs. When travelers visit another country, one of the simplest avenues for them to experience the local culture is food. Unlike other cultural elements, many of which have become diluted because of globalization, native cuisines are still perceived as retaining the traditions, uniqueness, and diversity of individual cultures. It is more important than ever for people and countries to expand and preserve their respective cultural currencies. In this respect, taking a cultural approach to Korean cuisine is a fascinating and meaningful endeavor. In light of the recent publication of a few articles dealing with the symbolic significance and meaning behind Korean cuisine, an effort to compile a list of the distinctive cultural properties of Korean food seems vital. Furthermore, presenting the aesthetics of Korean food through a method that integrates science and culture is a very significant task. The authors of this paper firmly believe in its potential to advance the globalization of Korean food.

  3. Voxel-by-voxel analysis of ECD-brain SPECT can separate penumbra from irreversibly damaged tissue at the acute phase of stroke

    International Nuclear Information System (INIS)

    Darcourt, J.; Migneco, O.; David, O.; Bussiere, F.; Mahagne, M.H.; Dunac, A.; Baron, J.C.

    2002-01-01

    Aim. At the acute phase of ischemic stroke, the target of treatment is still salvageable hypoperfused cerebral tissue; so called penumbra. We tested the possibility of separating on early ECD brain SPECT penumbral voxels (P) from irreversibly damaged damaged tissue (IDT). We used ECD which is not only a perfusion tracer but also a metabolic marker. Materials and methods. We prospectively studied 18 patients who underwent ECD-SPECT within the 12 hours following a first-ever acute middle cerebral artery stroke. Neurological evaluation was performed using the Orgogozo's scale at admission and 3 months later in order to calculate and evolution index (IE%) (Martinez-Vila et al.). SPECT data were obtained using a triple head camera equipped with fan beam collimators one hour after injection of 1000 MBq of 99mTc-ECD. On reconstructed images gray matter voxels were automatically segmented. Contralateral healthy hemisphere was used as reference leading to the identification of 3 cortical voxel types: normal (N-SPECT) above 80%; penumbra (P-SPECT) between 80% and 40% and IDT (IDT-SPECT) below 40%. 10 patients also underwent a T2 weighted 3D MRI study at 3 months. Cortical voxels with hypersignal served as reference for IDT (IDT-MRI) the others were considered normal (N-MRI). SPECT and MRI data were co-registered. Therefore each voxel belonged to one of 6 categories (3 SPECT x 2 MRI). Results. (1) The SPECT thresholds were validated on the MRI subgroup. 99% of the N-SPECT voxels were normal on late MRI. 84% of IDT-SPECT voxels corresponded to IDT-MRI. 89% of P-SPECT voxels were normal on late MRI and 11% corresponded to IDT on late MRI. Other categories of voxels (N-SPECT IDT-MRI and IDT-SPECT N-MRI) represented less than 5%. (2) Percentages of each voxel SPECT type was correlated with the EI% on the entire population (Spearman test). P-SPECT extent correlated with EI% improvement (p<0.001) and IDT-SPECT with EI% worsening (p<0.001). Conclusion. Analysis of ECD cortical

  4. Helping Peers Seek Professional Treatment for Depression among Young South Koreans: An Application of the Theory of Planned Behavior

    Science.gov (United States)

    Lee, Sun Hae; Choi, Jung Ah; Park, Ji Hye

    2015-01-01

    This study examined the applicability of the theory of planned behavior to understand factors that influence whether young South Koreans help peers with depression to seek professional counseling services. The structural equation modeling on the survey data collected from 191 South Korean students suggests that subjective norms and behavioral…

  5. Computational voxel phantom, associated to anthropometric and anthropomorphic real phantom for dosimetry in human male pelvis radiotherapy

    International Nuclear Information System (INIS)

    Silva, Cleuza Helena Teixeira; Campos, Tarcisio Passos Ribeiro de

    2005-01-01

    This paper addresses a computational model of voxels through MCNP5 Code and the experimental development of an anthropometric and anthropomorphic phantom for dosimetry in human male pelvis brachytherapy focusing prostatic tumors. For elaboration of the computational model of the human male pelvis, anatomical section images from the Visible Man Project were applied. Such selected and digital images were associated to a numeric representation, one for each section. Such computational representation of the anatomical sections was transformed into a bi-dimensional mesh of equivalent tissue. The group of bidimensional meshes was concatenated forming the three-dimensional model of voxels to be used by the MCNP5 code. In association to the anatomical information, data from the density and chemical composition of the basic elements, representatives of the organs and involved tissues, were setup in a material database for the MCNP-5. The model will be applied for dosimetric evaluations in situations of irradiation of the human masculine pelvis. Such 3D model of voxel is associated to the code of transport of particles MCNP5, allowing future simulations. It was also developed the construction of human masculine pelvis phantom, based on anthropometric and anthropomorphic dates and in the use of representative equivalent tissues of the skin, fatty, muscular and glandular tissue, as well as the bony structure.This part of work was developed in stages, being built the bony cast first, later the muscular structures and internal organs. They were then jointly mounted and inserted in the skin cast. The representative component of the fatty tissue was incorporate and accomplished the final retouchings in the skin. The final result represents the development of two important essential tools for elaboration of computational and experimental dosimetry. Thus, it is possible its use in calibrations of pre-existent protocols in radiotherapy, as well as for tests of new protocols, besides

  6. Stimulus-Related Independent Component and Voxel-Wise Analysis of Human Brain Activity during Free Viewing of a Feature Film

    Science.gov (United States)

    Lahnakoski, Juha M.; Salmi, Juha; Jääskeläinen, Iiro P.; Lampinen, Jouko; Glerean, Enrico; Tikka, Pia; Sams, Mikko

    2012-01-01

    Understanding how the brain processes stimuli in a rich natural environment is a fundamental goal of neuroscience. Here, we showed a feature film to 10 healthy volunteers during functional magnetic resonance imaging (fMRI) of hemodynamic brain activity. We then annotated auditory and visual features of the motion picture to inform analysis of the hemodynamic data. The annotations were fitted to both voxel-wise data and brain network time courses extracted by independent component analysis (ICA). Auditory annotations correlated with two independent components (IC) disclosing two functional networks, one responding to variety of auditory stimulation and another responding preferentially to speech but parts of the network also responding to non-verbal communication. Visual feature annotations correlated with four ICs delineating visual areas according to their sensitivity to different visual stimulus features. In comparison, a separate voxel-wise general linear model based analysis disclosed brain areas preferentially responding to sound energy, speech, music, visual contrast edges, body motion and hand motion which largely overlapped the results revealed by ICA. Differences between the results of IC- and voxel-based analyses demonstrate that thorough analysis of voxel time courses is important for understanding the activity of specific sub-areas of the functional networks, while ICA is a valuable tool for revealing novel information about functional connectivity which need not be explained by the predefined model. Our results encourage the use of naturalistic stimuli and tasks in cognitive neuroimaging to study how the brain processes stimuli in rich natural environments. PMID:22496909

  7. Stimulus-related independent component and voxel-wise analysis of human brain activity during free viewing of a feature film.

    Science.gov (United States)

    Lahnakoski, Juha M; Salmi, Juha; Jääskeläinen, Iiro P; Lampinen, Jouko; Glerean, Enrico; Tikka, Pia; Sams, Mikko

    2012-01-01

    Understanding how the brain processes stimuli in a rich natural environment is a fundamental goal of neuroscience. Here, we showed a feature film to 10 healthy volunteers during functional magnetic resonance imaging (fMRI) of hemodynamic brain activity. We then annotated auditory and visual features of the motion picture to inform analysis of the hemodynamic data. The annotations were fitted to both voxel-wise data and brain network time courses extracted by independent component analysis (ICA). Auditory annotations correlated with two independent components (IC) disclosing two functional networks, one responding to variety of auditory stimulation and another responding preferentially to speech but parts of the network also responding to non-verbal communication. Visual feature annotations correlated with four ICs delineating visual areas according to their sensitivity to different visual stimulus features. In comparison, a separate voxel-wise general linear model based analysis disclosed brain areas preferentially responding to sound energy, speech, music, visual contrast edges, body motion and hand motion which largely overlapped the results revealed by ICA. Differences between the results of IC- and voxel-based analyses demonstrate that thorough analysis of voxel time courses is important for understanding the activity of specific sub-areas of the functional networks, while ICA is a valuable tool for revealing novel information about functional connectivity which need not be explained by the predefined model. Our results encourage the use of naturalistic stimuli and tasks in cognitive neuroimaging to study how the brain processes stimuli in rich natural environments.

  8. Stimulus-related independent component and voxel-wise analysis of human brain activity during free viewing of a feature film.

    Directory of Open Access Journals (Sweden)

    Juha M Lahnakoski

    Full Text Available Understanding how the brain processes stimuli in a rich natural environment is a fundamental goal of neuroscience. Here, we showed a feature film to 10 healthy volunteers during functional magnetic resonance imaging (fMRI of hemodynamic brain activity. We then annotated auditory and visual features of the motion picture to inform analysis of the hemodynamic data. The annotations were fitted to both voxel-wise data and brain network time courses extracted by independent component analysis (ICA. Auditory annotations correlated with two independent components (IC disclosing two functional networks, one responding to variety of auditory stimulation and another responding preferentially to speech but parts of the network also responding to non-verbal communication. Visual feature annotations correlated with four ICs delineating visual areas according to their sensitivity to different visual stimulus features. In comparison, a separate voxel-wise general linear model based analysis disclosed brain areas preferentially responding to sound energy, speech, music, visual contrast edges, body motion and hand motion which largely overlapped the results revealed by ICA. Differences between the results of IC- and voxel-based analyses demonstrate that thorough analysis of voxel time courses is important for understanding the activity of specific sub-areas of the functional networks, while ICA is a valuable tool for revealing novel information about functional connectivity which need not be explained by the predefined model. Our results encourage the use of naturalistic stimuli and tasks in cognitive neuroimaging to study how the brain processes stimuli in rich natural environments.

  9. Cultural Identity in Korean English

    Science.gov (United States)

    Chang, Bok-Myung

    2010-01-01

    This study aims to investigate the cultural identity of Korean English and to make the intercultural communications among non-native speakers successful. The purposes of this study can be summarized as follows: 1) to recognize the concept of English as an International Language (EIL), 2) to emphasize cross-cultural understanding in the globalized…

  10. Revised dietary guidelines for Koreans.

    Science.gov (United States)

    Jang, Young Ai; Lee, Haeng Shin; Kim, Bok Hee; Lee, Yoonna; Lee, Hae Jeung; Moon, Jae Jin; Kim, Cho-il

    2008-01-01

    With rapidly changing dietary environment, dietary guidelines for Koreans were revised and relevant action guides were developed. First, the Dietary Guidelines Advisory Committee was established with experts and government officials from the fields of nutrition, preventive medicine, health promotion, agriculture, education and environment. The Committee set dietary goals for Koreans aiming for a better nutrition state of all after a thorough review and analysis of recent information related to nutritional status and/or problems of Korean population, changes in food production/supply, disease pattern, health policy and agricultural policy. Then, the revised dietary guidelines were proposed to accomplish these goals in addition to 6 different sets of dietary action guides to accommodate specific nutrition and health problems of respective age groups. Subsequently, these guidelines and guides were subjected to the focus group review, consumer perception surveys, and a public hearing for general and professional comments. Lastly, the language was clarified in terms of public understanding and phraseology. The revised Dietary guidelines for Koreans are as follows: eat a variety of grains, vegetables, fruits, fish, meat, poultry and dairy products; choose salt-preserved foods less, and use less salt when you prepare foods; increase physical activity for a healthy weight, and balance what you eat with your activity; enjoy every meal, and do not skip breakfast; if you drink alcoholic beverages, do so in moderation; prepare foods properly, and order sensible amounts; enjoy our rice-based diet.

  11. Attention enhances multi-voxel representation of novel objects in frontal, parietal and visual cortices.

    Science.gov (United States)

    Woolgar, Alexandra; Williams, Mark A; Rich, Anina N

    2015-04-01

    Selective attention is fundamental for human activity, but the details of its neural implementation remain elusive. One influential theory, the adaptive coding hypothesis (Duncan, 2001, An adaptive coding model of neural function in prefrontal cortex, Nature Reviews Neuroscience 2:820-829), proposes that single neurons in certain frontal and parietal regions dynamically adjust their responses to selectively encode relevant information. This selective representation may in turn support selective processing in more specialized brain regions such as the visual cortices. Here, we use multi-voxel decoding of functional magnetic resonance images to demonstrate selective representation of attended--and not distractor--objects in frontal, parietal, and visual cortices. In addition, we highlight a critical role for task demands in determining which brain regions exhibit selective coding. Strikingly, representation of attended objects in frontoparietal cortex was highest under conditions of high perceptual demand, when stimuli were hard to perceive and coding in early visual cortex was weak. Coding in early visual cortex varied as a function of attention and perceptual demand, while coding in higher visual areas was sensitive to the allocation of attention but robust to changes in perceptual difficulty. Consistent with high-profile reports, peripherally presented objects could also be decoded from activity at the occipital pole, a region which corresponds to the fovea. Our results emphasize the flexibility of frontoparietal and visual systems. They support the hypothesis that attention enhances the multi-voxel representation of information in the brain, and suggest that the engagement of this attentional mechanism depends critically on current task demands. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Gray Matter Alterations in Adults with Attention-Deficit/Hyperactivity Disorder Identified by Voxel Based Morphometry

    Science.gov (United States)

    Seidman, Larry J.; Biederman, Joseph; Liang, Lichen; Valera, Eve M.; Monuteaux, Michael C.; Brown, Ariel; Kaiser, Jonathan; Spencer, Thomas; Faraone, Stephen V.; Makris, Nikos

    2014-01-01

    Background Gray and white matter volume deficits have been reported in many structural magnetic resonance imaging (MRI) studies of children with attention-deficit/hyperactivity disorder (ADHD); however, there is a paucity of structural MRI studies of adults with ADHD. This study used voxel based morphometry and applied an a priori region of interest approach based on our previous work, as well as from well-developed neuroanatomical theories of ADHD. Methods Seventy-four adults with DSM-IV ADHD and 54 healthy control subjects comparable on age, sex, race, handedness, IQ, reading achievement, frequency of learning disabilities, and whole brain volume had an MRI on a 1.5T Siemens scanner. A priori region of interest hypotheses focused on reduced volumes in ADHD in dorsolateral prefrontal cortex, anterior cingulate cortex, caudate, putamen, inferior parietal lobule, and cerebellum. Analyses were carried out by FSL-VBM 1.1. Results Relative to control subjects, ADHD adults had significantly smaller gray matter volumes in parts of six of these regions at p ≤ .01, whereas parts of the dorsolateral prefrontal cortex and inferior parietal lobule were significantly larger in ADHD at this threshold. However, a number of other regions were smaller and larger in ADHD (especially fronto-orbital cortex) at this threshold. Only the caudate remained significantly smaller at the family-wise error rate. Conclusions Adults with ADHD have subtle volume reductions in the caudate and possibly other brain regions involved in attention and executive control supporting frontostriatal models of ADHD. Modest group brain volume differences are discussed in the context of the nature of the samples studied and voxel based morphometry methodology. PMID:21183160

  13. MO-F-BRA-04: Voxel-Based Statistical Analysis of Deformable Image Registration Error via a Finite Element Method.

    Science.gov (United States)

    Li, S; Lu, M; Kim, J; Glide-Hurst, C; Chetty, I; Zhong, H

    2012-06-01

    Purpose Clinical implementation of adaptive treatment planning is limited by the lack of quantitative tools to assess deformable image registration errors (R-ERR). The purpose of this study was to develop a method, using finite element modeling (FEM), to estimate registration errors based on mechanical changes resulting from them. Methods An experimental platform to quantify the correlation between registration errors and their mechanical consequences was developed as follows: diaphragm deformation was simulated on the CT images in patients with lung cancer using a finite element method (FEM). The simulated displacement vector fields (F-DVF) were used to warp each CT image to generate a FEM image. B-Spline based (Elastix) registrations were performed from reference to FEM images to generate a registration DVF (R-DVF). The F- DVF was subtracted from R-DVF. The magnitude of the difference vector was defined as the registration error, which is a consequence of mechanically unbalanced energy (UE), computed using 'in-house-developed' FEM software. A nonlinear regression model was used based on imaging voxel data and the analysis considered clustered voxel data within images. Results A regression model analysis showed that UE was significantly correlated with registration error, DVF and the product of registration error and DVF respectively with R̂2=0.73 (R=0.854). The association was verified independently using 40 tracked landmarks. A linear function between the means of UE values and R- DVF*R-ERR has been established. The mean registration error (N=8) was 0.9 mm. 85.4% of voxels fit this model within one standard deviation. Conclusions An encouraging relationship between UE and registration error has been found. These experimental results suggest the feasibility of UE as a valuable tool for evaluating registration errors, thus supporting 4D and adaptive radiotherapy. The research was supported by NIH/NCI R01CA140341. © 2012 American Association of Physicists in

  14. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  15. Dose calculation on voxels phantoms using the GEANT4 code

    International Nuclear Information System (INIS)

    Martins, Maximiano C.; Santos, Denison S.; Queiroz Filho, Pedro P.; Begalli, Marcia

    2009-01-01

    This work implemented an anthropomorphic phantom of voxels on the structure of Monte Carlo GEANT4, for utilization by professionals from the radioprotection, external dosimetry and medical physics. This phantom allows the source displacement that can be isotropic punctual, plain beam, linear or radioactive gas, in order to obtain diverse irradiation geometries. In them, the radioactive sources exposure is simulated viewing the determination of effective dose or the dose in each organ of the human body. The Zubal head and body trunk phantom was used, and we can differentiate the organs and tissues by the chemical constitution in soft tissue, lung tissue, bone tissue, water and air. The calculation method was validated through the comparison with other well established method, the Visual Monte Carlo (VMC). Besides, a comparison was done with the international recommendation for the evaluation of dose by exposure to punctual sources, described in the document TECDOC - 1162- Generic Procedures for Assessment and Response During a Radiological Emergency, where analytical expressions for this calculation are given. Considerations are made on the validity limits of these expressions for various irradiation geometries, including linear sources, immersion into clouds and contaminated soils

  16. A voxel-based MRI morphometric study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Hao Jing; Li Kuncheng; Yang Yanhui; Wang Wei; Li Ke; Yan Bin; Shan Baoci

    2005-01-01

    Objective: To assess the diagnostic value of voxel-based Morphometry (VBM) in studying Alzheimer's disease (AD). Methods: Graymatter density were comprehensive assessed by means of VBM on T 1 -weighted MRI volume sets in 19 patients with AD and 15 healthy subjects of similar age and gender ratio, 15 healthy adults. The data were collected on Siemens 1.5 T Sonata MRI systems and analyzed by SPM 99 to generate gray matter density map. Results: Relative to healthy controls, significant clusters of reduced gray matter density were found to affect medial temporal lobe ( hippocampus) (P<0.001). For hippocampus, reduced gray matter density were 1529 in the right and 1281 in the left with right-sided predominance. Moreover, atrophy of right caudate head and left medial thalamus were showed. We demonstrate global asymmetrical cortical atrophy with sparing of the sensorimotor cortex, occipital lobe and cerebellum. Conclusion: The results from VBM are in perfect agreement with those of earlier neuroimaging, which confirmed its value in demonstrating neuroanatomy of AD. VBM, the simple and automatic approach providing a full-brain assessment of AD morphology, has a good clinical perspective. (authors)

  17. DTI Analysis of Presbycusis Using Voxel-Based Analysis.

    Science.gov (United States)

    Ma, W; Li, M; Gao, F; Zhang, X; Shi, L; Yu, L; Zhao, B; Chen, W; Wang, G; Wang, X

    2016-07-14

    Presbycusis is the most common sensory deficit in the aging population. A recent study reported using a DTI-based tractography technique to identify a lack of integrity in a portion of the auditory pathway in patients with presbycusis. The aim of our study was to investigate the white matter pathology of patients with presbycusis by using a voxel-based analysis that is highly sensitive to local intensity changes in DTI data. Fifteen patients with presbycusis and 14 age- and sex-matched healthy controls were scanned on a 3T scanner. Fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity were obtained from the DTI data. Intergroup statistics were implemented on these measurements, which were transformed to Montreal Neurological Institute coordinates by using a nonrigid image registration method called large deformation diffeomorphic metric mapping. Increased axial diffusivity, radial diffusivity, and mean diffusivity and decreased fractional anisotropy were found near the right-side hearing-related areas in patients with presbycusis. Increased radial diffusivity and mean diffusivity were also found near a language-related area (Broca area) in patients with presbycusis. Our findings could be important for exploring reliable imaging evidence of presbycusis and could complement an ROI-based approach. © 2016 American Society of Neuroradiology.

  18. Validation of voxel-based morphometry (VBM) based on MRI

    Science.gov (United States)

    Yang, Xueyu; Chen, Kewei; Guo, Xiaojuan; Yao, Li

    2007-03-01

    Voxel-based morphometry (VBM) is an automated and objective image analysis technique for detecting differences in regional concentration or volume of brain tissue composition based on structural magnetic resonance (MR) images. VBM has been used widely to evaluate brain morphometric differences between different populations, but there isn't an evaluation system for its validation until now. In this study, a quantitative and objective evaluation system was established in order to assess VBM performance. We recruited twenty normal volunteers (10 males and 10 females, age range 20-26 years, mean age 22.6 years). Firstly, several focal lesions (hippocampus, frontal lobe, anterior cingulate, back of hippocampus, back of anterior cingulate) were simulated in selected brain regions using real MRI data. Secondly, optimized VBM was performed to detect structural differences between groups. Thirdly, one-way ANOVA and post-hoc test were used to assess the accuracy and sensitivity of VBM analysis. The results revealed that VBM was a good detective tool in majority of brain regions, even in controversial brain region such as hippocampus in VBM study. Generally speaking, much more severity of focal lesion was, better VBM performance was. However size of focal lesion had little effects on VBM analysis.

  19. Construction of voxel head phantom and application to BNCT dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik; Lee, Choon Ik; Lee, Jai Ki [Hanyang Univ., Seoul (Korea, Republic of)

    2001-06-15

    Voxel head phantom for overcoming the limitation of mathematical phantom in depicting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for voxel Monte Carlo calculation. Simple binary voxel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct voxel head phantom. Comparison od doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of voxel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is 30{mu}g/g to 3 {mu}g/g. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  20. What do differences between multi-voxel and univariate analysis mean? How subject-, voxel-, and trial-level variance impact fMRI analysis.

    Science.gov (United States)

    Davis, Tyler; LaRocque, Karen F; Mumford, Jeanette A; Norman, Kenneth A; Wagner, Anthony D; Poldrack, Russell A

    2014-08-15

    Multi-voxel pattern analysis (MVPA) has led to major changes in how fMRI data are analyzed and interpreted. Many studies now report both MVPA results and results from standard univariate voxel-wise analysis, often with the goal of drawing different conclusions from each. Because MVPA results can be sensitive to latent multidimensional representations and processes whereas univariate voxel-wise analysis cannot, one conclusion that is often drawn when MVPA and univariate results differ is that the activation patterns underlying MVPA results contain a multidimensional code. In the current study, we conducted simulations to formally test this assumption. Our findings reveal that MVPA tests are sensitive to the magnitude of voxel-level variability in the effect of a condition within subjects, even when the same linear relationship is coded in all voxels. We also find that MVPA is insensitive to subject-level variability in mean activation across an ROI, which is the primary variance component of interest in many standard univariate tests. Together, these results illustrate that differences between MVPA and univariate tests do not afford conclusions about the nature or dimensionality of the neural code. Instead, targeted tests of the informational content and/or dimensionality of activation patterns are critical for drawing strong conclusions about the representational codes that are indicated by significant MVPA results. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Long work hours and obesity in Korean adult workers.

    Science.gov (United States)

    Jang, Tae-Won; Kim, Hyoung-Ryoul; Lee, Hye-Eun; Myong, Jun-Pyo; Koo, Jung-Wan

    2014-01-01

    The present study was designed to identify the association between work hours and obesity in Korean adult manual and nonmanual workers, and to determine whether there is a gender difference in this association. The study was conducted using Korean National Health and Nutrition Examination Survey data collected between 2007 and 2010. Individuals aged below 25 or over 64 years, pregnant women, part-time workers, soldiers, housewives and students were excluded. The total number of individuals included in the analysis was 8,889 (5,241 male and 3,648 female subjects). The outcome variable was obesity, defined as body mass index ≥25 kg/m(2). Variables considered in the model were age, education, income, marital status, alcohol drinking, smoking, daily energy intake, physical activity, sleep hours per day, the type of job, work hours, and work schedule. Work hours were categorized as 60 hours per week. In the multiple SURVEYLOGISTIC regression analyses, the adjusted odds ratio of obesity for long work hours (>60 hours per week) in male manual workers was 1.647 (95% confidence interval 1.262-2.151). Long work hours did not significantly increase the odds ratio for obesity in male nonmanual workers and female manual and nonmanual workers. More than 60 work hours per week increased the risk of obesity in Korean male manual workers. This result might be helpful in preventing obesity in Korean adult workers, especially male manual workers.

  2. Estimating radiation risk induced by CT screening for Korean population

    Science.gov (United States)

    Yang, Won Seok; Yang, Hye Jeong; Min, Byung In

    2017-02-01

    The purposes of this study are to estimate the radiation risks induced by chest/abdomen computed tomography (CT) screening for healthcare and to determine the cancer risk level of the Korean population compared to other populations. We used an ImPACT CT Patient Dosimetry Calculator to compute the organ effective dose induced by CT screening (chest, low-dose chest, abdomen/pelvis, and chest/abdomen/pelvis CT). A risk model was applied using principles based on the BEIR VII Report in order to estimate the lifetime attributable risk (LAR) using the Korean Life Table 2010. In addition, several countries including Hong Kong, the United States (U.S.), and the United Kingdom, were selected for comparison. Herein, each population exposed radiation dose of 100 mSv was classified according to country, gender and age. For each CT screening the total organ effective dose calculated by ImPACT was 6.2, 1.5, 5.2 and 11.4 mSv, respectively. In the case of Korean female LAR, it was similar to Hong Kong female but lower than those of U.S. and U.K. females, except for those in their twenties. The LAR of Korean males was the highest for all types of CT screening. However, the difference of the risk level was negligible because of the quite low value.

  3. Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T

    International Nuclear Information System (INIS)

    Horng, Annie; Stockinger, M.; Notohamiprodjo, M.; Raya, J.G.; Pietschmann, M.; Hoehne-Hueckstaedt, U.; Glitsch, U.; Ellegast, R.; Hering, K.G.; Glaser, C.

    2015-01-01

    To implement a novel voxel-based technique to identify statistically significant local cartilage deformation and analyze in-vivo topographic knee cartilage deformation patterns using a voxel-based thickness map approach for high-flexion postures. Sagittal 3T 3D-T1w-FLASH-WE-sequences of 10 healthy knees were acquired before and immediately after loading (kneeling/squatting/heel sitting/knee bends). After cartilage segmentation, 3D-reconstruction and 3D-registration, colour-coded deformation maps were generated by voxel-based subtraction of loaded from unloaded datasets to visualize cartilage thickness changes in all knee compartments. Compression areas were found bifocal at the peripheral medial/caudolateral patella, both posterior femoral condyles and both anterior/central tibiae. Local cartilage thickening were found adjacent to the compression areas. Significant local strain ranged from +13 to -15 %. Changes were most pronounced after squatting, least after knee bends. Shape and location of deformation areas varied slightly with the loading paradigm, but followed a similar pattern consistent between different individuals. Voxel-based deformation maps identify individual in-vivo load-specific and posture-associated strain distribution in the articular cartilage. The data facilitate understanding individual knee loading properties and contribute to improve biomechanical 3 models. They lay a base to investigate the relationship between cartilage degeneration patterns in common osteoarthritis and areas at risk of cartilage wear due to mechanical loading in work-related activities. (orig.)

  4. Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Horng, Annie; Stockinger, M.; Notohamiprodjo, M. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Raya, J.G. [New York University Langone Medical Center, Center for Biomedical Imaging, New York, NY (United States); Pietschmann, M. [Ludwig-Maximilians-University Hospital Munich, Department of Orthopedic Surgery, Munich (Germany); Hoehne-Hueckstaedt, U.; Glitsch, U.; Ellegast, R. [Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin (Germany); Hering, K.G. [Miner' s Hospital, Department of Diagnostic Radiology, Dortmund (Germany); Glaser, C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); RZM Zentrum, Munich (Germany)

    2015-06-01

    To implement a novel voxel-based technique to identify statistically significant local cartilage deformation and analyze in-vivo topographic knee cartilage deformation patterns using a voxel-based thickness map approach for high-flexion postures. Sagittal 3T 3D-T1w-FLASH-WE-sequences of 10 healthy knees were acquired before and immediately after loading (kneeling/squatting/heel sitting/knee bends). After cartilage segmentation, 3D-reconstruction and 3D-registration, colour-coded deformation maps were generated by voxel-based subtraction of loaded from unloaded datasets to visualize cartilage thickness changes in all knee compartments. Compression areas were found bifocal at the peripheral medial/caudolateral patella, both posterior femoral condyles and both anterior/central tibiae. Local cartilage thickening were found adjacent to the compression areas. Significant local strain ranged from +13 to -15 %. Changes were most pronounced after squatting, least after knee bends. Shape and location of deformation areas varied slightly with the loading paradigm, but followed a similar pattern consistent between different individuals. Voxel-based deformation maps identify individual in-vivo load-specific and posture-associated strain distribution in the articular cartilage. The data facilitate understanding individual knee loading properties and contribute to improve biomechanical 3 models. They lay a base to investigate the relationship between cartilage degeneration patterns in common osteoarthritis and areas at risk of cartilage wear due to mechanical loading in work-related activities. (orig.)

  5. [Successful Aging of Korean Older Adults based on Rowe and Kahn's Model: A Comparative Study According to the Use of Community Senior Facilities].

    Science.gov (United States)

    Lee, Soo Jin; Song, Misoon

    2015-04-01

    This study was conducted to examine the prevalence of successful aging and factors influencing successful aging. This was a secondary analysis study. Data were analyzed from 10,462 elderly people who participated in the 2011 National Elderly Survey. According to the use of community senior facilities, participants were divided into 4 groups: those who used senior centers (group A, n=580), village senior clubs (group B, n=3,240), both of the 2 facilities (group C, n=339), and neither of the 2 facilities (group D, n=6,303). Cross-tabulation and logistic regression were performed. The prevalence of successful aging was highest in group C (20.94%) and lowest in group D (10.41%). The physical & mental function and active engagement domains were highest in group C, while they were lowest in group D. The disease & risk factors domain were highest in group A, while lowest in group B. An educational level of middleschool or higher and income level in the third or higher quintile were significant factors for predicting successful aging in all groups. These results provide a basis for designing prevention and management programs as interventions to increase the prevalence of successful aging in Korean older adults.

  6. A voxel-based technique to estimate the volume of trees from terrestrial laser scanner data

    Science.gov (United States)

    Bienert, A.; Hess, C.; Maas, H.-G.; von Oheimb, G.

    2014-06-01

    The precise determination of the volume of standing trees is very important for ecological and economical considerations in forestry. If terrestrial laser scanner data are available, a simple approach for volume determination is given by allocating points into a voxel structure and subsequently counting the filled voxels. Generally, this method will overestimate the volume. The paper presents an improved algorithm to estimate the wood volume of trees using a voxel-based method which will correct for the overestimation. After voxel space transformation, each voxel which contains points is reduced to the volume of its surrounding bounding box. In a next step, occluded (inner stem) voxels are identified by a neighbourhood analysis sweeping in the X and Y direction of each filled voxel. Finally, the wood volume of the tree is composed by the sum of the bounding box volumes of the outer voxels and the volume of all occluded inner voxels. Scan data sets from several young Norway maple trees (Acer platanoides) were used to analyse the algorithm. Therefore, the scanned trees as well as their representing point clouds were separated in different components (stem, branches) to make a meaningful comparison. Two reference measurements were performed for validation: A direct wood volume measurement by placing the tree components into a water tank, and a frustum calculation of small trunk segments by measuring the radii along the trunk. Overall, the results show slightly underestimated volumes (-0.3% for a probe of 13 trees) with a RMSE of 11.6% for the individual tree volume calculated with the new approach.

  7. Yield and Depth of Burial Hydrodynamic Calculations in Granodiorite: Implications for the North Korean Test Site

    Science.gov (United States)

    2011-09-01

    the existence of a test site body wave magnitude (mb) bias between U. S. and the former Soviet Union test sites in Nevada and Semipalatinsk . The use...YIELD AND DEPTH OF BURIAL HYDRODYNAMIC CALCULATIONS IN GRANODIORITE:IMPLICATIONS FOR THE NORTH KOREAN TEST SITE Esteban Rougier, Christopher R...Korean test site and the May 2009 test . When compared to the Denny and Johnson (1991) and to the Heard and Ackerman (1967) cavity radius scaling models

  8. Quantitative Assessment of Cervical Vertebral Maturation Using Cone Beam Computed Tomography in Korean Girls

    OpenAIRE

    Byun, Bo-Ram; Kim, Yong-Il; Yamaguchi, Tetsutaro; Maki, Koutaro; Son, Woo-Sung

    2015-01-01

    This study was aimed to examine the correlation between skeletal maturation status and parameters from the odontoid process/body of the second vertebra and the bodies of third and fourth cervical vertebrae and simultaneously build multiple regression models to be able to estimate skeletal maturation status in Korean girls. Hand-wrist radiographs and cone beam computed tomography (CBCT) images were obtained from 74 Korean girls (6?18 years of age). CBCT-generated cervical vertebral maturation ...

  9. Efficiency factors for Phoswich based lung monitor using ICRP Voxel phantoms

    International Nuclear Information System (INIS)

    Manohari, M.; Mathiyarasu, R.; Rajagopal, V.; Jose, M.T.; Venkatraman, B.

    2016-01-01

    The actinide contamination in lungs is measured either using array of HPGe detector or Phoswich based lung monitors. This paper discusses the results obtained during numerical calibration of Phoswich based lung counting system using ICRP VOXEL phantoms. The results are also compared with measured efficiency values obtained using LLNL phantom. The efficiency factors of 241 Am present in the lungs for phoswich detector was simulated using ICRP male voxel phantom and compared with experimentally observed values using LLNL Phantom. The observed deviation is 12%. The efficiency of the same for female subjects was estimated using ICRP female voxel phantom for both supine and posterior geometries

  10. A Comparison of Adaptation to Childhood Disability in Korean Immigrant and Korean Mothers.

    Science.gov (United States)

    Cho, Su-Je; Singer, George H. S.; Brenner, Betsy (Mary)

    2003-01-01

    A study examined the variables that exacerbated or buffered the impact of child problem behaviors and/or physical differences on 16 Korean mothers and 16 Korean American mothers of children with disabilities. Overall findings from data analyses were consistent with qualitative findings that Korean mothers experienced more difficulties than their…

  11. Korean Adoptee Identity: Adoptive and Ethnic Identity Profiles of Adopted Korean Americans

    Science.gov (United States)

    Beaupre, Adam J.; Reichwald, Reed; Zhou, Xiang; Raleigh, Elizabeth; Lee, Richard M.

    2015-01-01

    Adopted Korean adolescents face the task of grappling with their identity as Koreans and coming to terms with their adoptive status. In order to explore these dual identities, the authors conducted a person-centered study of the identity profiles of 189 adopted Korean American adolescents. Using cluster analytic procedures, the study examined…

  12. Korean society of mechanical engineers 60 years

    International Nuclear Information System (INIS)

    2005-12-01

    This book introduces 60 years of Korean society of mechanical engineers with birth, foundation, development process, change of enforcement regulation and articles of association, important data of this association, 60 years of parts, committee and branch, business of association like academic event, publication, technical development business, supporting research centers, bond Korean society of mechanical engineers and mechanical industry and development of related organizations, development for industrial fields and development direction of Korean society of mechanical engineers.

  13. Music in Korean shaman ritual.

    OpenAIRE

    Mills, Simon R.S.

    2012-01-01

    It is hard to sum up Korean Shamanism in a few sentences but, in short, it could be described as the traditional syncretic folk religion of Korea. It mixes together ritual practices, beliefs, symbols and myths from Buddhism, Taoism, and folklore and adds elements commonly associated with nature religions and shamanism – including the use of techniques such as divination, trance, and mediumship. As with many other syncretic folk religions around the globe, there is very little in the way o...

  14. Korean Affairs Report No. 215.

    Science.gov (United States)

    1982-05-25

    21 Aug 81 p 2] 89 ROMANIAN FILM SHOW—The following attended the opening of a Romanian film week on 20 August at the Nagwon Cinema , in honor of the...decoration of the Pyongyang City Sosong District General Restaurant with the title of Guard Commerce. Premier Li and his party confer with the Malaysian ...National Power transmission workers’ meeting closes a two-day meeting held in Moranbong Theater. The (north) Korean and Malaysian governments sign

  15. The Ongoing Korean War at the Sinch’ŏn Museum in North Korea

    Directory of Open Access Journals (Sweden)

    Sunghoon Han

    2015-03-01

    Full Text Available This essay analyzes the Sinch’ŏn Massacre and its memorialization at the Sinch’ŏn Museum of American War Atrocities in North Korea by placing the massacre within the context of North Korea’s political history. The museum illustrates Pyongyang’s perspective on the Korean War as a “war of liberation” and the museum’s role in the political education of the North Korean people, not simply as victims of American war atrocities but as “martyrs” and model citizens. Within the geopolitics of confrontation between North Korea and the United States since the Korean War, the Sinch’ŏn Museum has served to foster anti-American nationalism in North Korea. While the museum has served this specific purpose within the North Korean context, it should be compared with other examples of war memorialization that serve the function of identity formation for a sense of national unity.

  16. Aging effects on cerebral asymmetry: a voxel-based morphometry and diffusion tensor imaging study.

    Science.gov (United States)

    Takao, Hidemasa; Abe, Osamu; Yamasue, Hidenori; Aoki, Shigeki; Kasai, Kiyoto; Sasaki, Hiroki; Ohtomo, Kuni

    2010-01-01

    The hemispheres of the human brain are functionally and structurally asymmetric. The purpose of this study was to evaluate the effects of aging on gray and white matter asymmetry. Two hundred twenty-six right-handed normal volunteers aged 21-71 years were included in this study. The effects of aging on gray matter volume asymmetry and white matter fractional anisotropy asymmetry were evaluated with use of voxel-based morphometry and voxel-based analysis of fractional anisotropy maps derived from diffusion tensor imaging (DTI), respectively. The voxel-based morphometry showed no significant correlation between age and gray matter volume asymmetry. The voxel-based analysis of DTI also showed no significant correlation between age and white matter fractional anisotropy asymmetry. Our results showed no significant effects of aging on either gray matter volume asymmetry or white matter fractional anisotropy asymmetry.

  17. Automated voxelization of 3D atom probe data through kernel density estimation

    International Nuclear Information System (INIS)

    Srinivasan, Srikant; Kaluskar, Kaustubh; Dumpala, Santoshrupa; Broderick, Scott; Rajan, Krishna

    2015-01-01

    Identifying nanoscale chemical features from atom probe tomography (APT) data routinely involves adjustment of voxel size as an input parameter, through visual supervision, making the final outcome user dependent, reliant on heuristic knowledge and potentially prone to error. This work utilizes Kernel density estimators to select an optimal voxel size in an unsupervised manner to perform feature selection, in particular targeting resolution of interfacial features and chemistries. The capability of this approach is demonstrated through analysis of the γ / γ’ interface in a Ni–Al–Cr superalloy. - Highlights: • Develop approach for standardizing aspects of atom probe reconstruction. • Use Kernel density estimators to select optimal voxel sizes in an unsupervised manner. • Perform interfacial analysis of Ni–Al–Cr superalloy, using new automated approach. • Optimize voxel size to preserve the feature of interest and minimizing loss / noise.

  18. Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment

    NARCIS (Netherlands)

    Parsa, A.; Ibrahim, N.; Hassan, B.; Motroni, A.; van der Stelt, P.; Wismeijer, D.

    2012-01-01

    Purpose: To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Materials and Methods: Ten partially edentulous human mandibular cadavers

  19. Diffusion tensor imaging and voxel based morphometry study in amyotrophic lateral sclerosis: relationships with motor disability

    OpenAIRE

    Thivard, Lionel; Pradat, Pierre‐François; Lehéricy, Stéphane; Lacomblez, Lucette; Dormont, Didier; Chiras, Jacques; Benali, Habib; Meininger, Vincent

    2007-01-01

    International audience; The aim of this study was to investigate the extent of cortical and subcortical lesions in amyotrophic lateral sclerosis (ALS) using, in combination, voxel based diffusion tensor imaging (DTI) and voxel based morphometry (VBM). We included 15 patients with definite or probable ALS and 25 healthy volunteers. Patients were assessed using the revised ALS Functional Rating Scale (ALSFRS-R). In patients, reduced fractional anisotropy was found in bilateral corticospinal tra...

  20. Srna-Monte Carlo codes for proton transport simulation in combined and voxelized geometries

    CERN Document Server

    Ilic, R D; Stankovic, S J

    2002-01-01

    This paper describes new Monte Carlo codes for proton transport simulations in complex geometrical forms and in materials of different composition. The SRNA codes were developed for three dimensional (3D) dose distribution calculation in proton therapy and dosimetry. The model of these codes is based on the theory of proton multiple scattering and a simple model of compound nucleus decay. The developed package consists of two codes: SRNA-2KG and SRNA-VOX. The first code simulates proton transport in combined geometry that can be described by planes and second order surfaces. The second one uses the voxelized geometry of material zones and is specifically adopted for the application of patient computer tomography data. Transition probabilities for both codes are given by the SRNADAT program. In this paper, we will present the models and algorithms of our programs, as well as the results of the numerical experiments we have carried out applying them, along with the results of proton transport simulation obtaine...

  1. Srna - Monte Carlo codes for proton transport simulation in combined and voxelized geometries

    Directory of Open Access Journals (Sweden)

    Ilić Radovan D.

    2002-01-01

    Full Text Available This paper describes new Monte Carlo codes for proton transport simulations in complex geometrical forms and in materials of different composition. The SRNA codes were developed for three dimensional (3D dose distribution calculation in proton therapy and dosimetry. The model of these codes is based on the theory of proton multiple scattering and a simple model of compound nucleus decay. The developed package consists of two codes: SRNA-2KG and SRNA-VOX. The first code simulates proton transport in combined geometry that can be described by planes and second order surfaces. The second one uses the voxelized geometry of material zones and is specifically adopted for the application of patient computer tomography data. Transition probabilities for both codes are given by the SRNADAT program. In this paper, we will present the models and algorithms of our programs, as well as the results of the numerical experiments we have carried out applying them, along with the results of proton transport simulation obtained through the PETRA and GEANT programs. The simulation of the proton beam characterization by means of the Multi-Layer Faraday Cup and spatial distribution of positron emitters obtained by our program indicate the imminent application of Monte Carlo techniques in clinical practice.

  2. Automatic calibration method of voxel size for cone-beam 3D-CT scanning system

    International Nuclear Information System (INIS)

    Yang Min; Wang Xiaolong; Wei Dongbo; Liu Yipeng; Meng Fanyong; Li Xingdong; Liu Wenli

    2014-01-01

    For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy. (authors)

  3. A Voxel-Based Approach to Explore Local Dose Differences Associated With Radiation-Induced Lung Damage

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Giuseppe [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Monti, Serena [IRCCS SDN, Naples (Italy); D' Avino, Vittoria [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Conson, Manuel [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples (Italy); Liuzzi, Raffaele [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Pressello, Maria Cristina [Department of Health Physics, S. Camillo-Forlanini Hospital, Rome (Italy); Donato, Vittorio [Department of Radiation Oncology, S. Camillo-Forlanini Hospital, Rome (Italy); Deasy, Joseph O. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY (United States); Quarantelli, Mario [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Pacelli, Roberto [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy); Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples (Italy); Cella, Laura, E-mail: laura.cella@cnr.it [Institute of Biostructure and Bioimaging, National Research Council, Naples (Italy)

    2016-09-01

    Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. The coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high

  4. Foreign Exchange Exposures of Korean Firms

    Directory of Open Access Journals (Sweden)

    Sungbin Cho

    2011-03-01

    Full Text Available We measure foreign exchange exposures as sensitivity of firm's value to FX premium in the CAPM plus FX premium model, and try to find determinants of the exposures; using data of non-financial companies listed in the Korea Exchange from the year 2007 to 2008. Main findings are as follows. If Korean won depreciates, only a small number of firms is benefitted while majority of firms are harmed to the contrary of common knowledge. As a firm's export increases, the foreign exchange exposure increases up to a certain level and after that it declines. And, smaller firms of negative foreign exchange exposures are more sensitive to foreign exchange changes. These suggest heterogeneous effects of foreign exchange rates on industries and firms.

  5. Cross-language Transfer of Metalinguistic Skills: Evidence from Spelling English Words by Korean Students in Grades 4, 5 and 6.

    Science.gov (United States)

    Yeon, Sookkyung; Bae, Han Suk; Joshi, R Malatesha

    2017-11-01

    The present study examined unique and shared contributions of Korean (first language) phonological, orthographic and morphological awareness (PA, OA and MA, respectively) to English (second/foreign language) spelling among 287 fourth-grade, fifth-grade and sixth-grade Korean children. Korean measures of PA, OA and MA were administered, in addition to English vocabulary and spelling measures. Results from structural equation modelling showed that PA, OA and MA were caused by one common construct, metalinguistic awareness (META), and the contribution of Korean META to English spelling was statistically significant, controlling for English vocabulary. In particular, Korean MA and PA played unique roles in explaining English spelling; whereas Korean OA did not significantly contribute to English spelling. Findings from the present study provided empirical evidence of first language META transfer effect on second/foreign language spelling development. Educational implications and future research ideas are discussed. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Crustal structure beneath the southern Korean Peninsula from local earthquakes

    Science.gov (United States)

    Kim, Kwang-Hee; Park, Jung-Ho; Park, Yongcheol; Hao, Tian-Yao; Kim, Han-Joon

    2017-05-01

    The 3-D subsurface structure beneath the southern Korean Peninsula is poorly known, even though such information could be key in verifying or rejecting several competing models of the tectonic evolution of East Asia. We constructed a 3-D velocity model of the upper crust beneath the southern Korean Peninsula using 19 935 P-wave arrivals from 747 earthquakes recorded by high-density local seismic networks. Results show significant lateral and vertical variations: velocity increases from northwest to southeast at shallow depths, and significant velocity variations are observed across the South Korea Tectonic Line between the Okcheon Fold Belt and the Youngnam Massif. Collision between the North and South China blocks during the Early Cretaceous might have caused extensive deformation and the observed negative velocity anomalies in the region. The results of the tomographic inversion, combined with the findings of previous studies of Bouguer and isostatic gravity anomalies, indicate the presence of high-density material in the upper and middle crust beneath the Gyeongsang Basin in the southeastern Korean Peninsula. Although our results partially support the indentation tectonic model, it is still premature to discard other tectonic evolution models because our study only covers the southern half of the peninsula.

  7. The Cultural Negotiations of Korean Immigrant Youth

    Science.gov (United States)

    Yeh, Christine J.; Ma, Pei-Wen; Madan-Bahel, Anvita; Hunter, Carla D.; Jung, Sunna; Kim, Angela B.; Akitaya, Kyoko; Sasaki, Kiyoko

    2005-01-01

    The authors investigated the process of cultural adjustment among 13 Korean immigrant youths using consensual qualitative research (C. E. Hill, B. J. Thompson, & E. N. Williams, 1997). Results indicate that Korean youth are expected to negotiate and shift their identities to meet differing expectations across various interpersonal contexts.…

  8. Group Psychodrama for Korean College Students

    Science.gov (United States)

    Chae, Soo Eun; Kim, Soo Jin

    2017-01-01

    Psychodrama was first introduced in the Korean literature in 1972, but its generalization to college students did not occur until the 1990s. Despite findings from psychodrama studies with Korean college students supporting psychodrama as effective for developing and maintaining good interpersonal relationships, as well as decreasing anxiety and…

  9. Handbook for Teaching Korean-American Students.

    Science.gov (United States)

    California State Dept. of Education, Sacramento. Bilingual Education Office.

    This handbook is designed for teachers, administrators, and other school personnel. It provides an explanation of the sociocultural and linguistic characteristics of Korean-Americans so educators can address their needs more effectively and orchestrate a better teaching environment by understanding and supporting the Korean-American cultural…

  10. Korean migration to North America: some prices that matter

    Directory of Open Access Journals (Sweden)

    J. D. Han

    2005-12-01

    theory is that depreciation in the value of the Canadian dollar relative to the U.S. dollar should cause some migrants to substitute Canada for the United States as their destination of choice. Using data on Korean immigration to Canada and the United States, we estimate a regression model to test this hypothesis. The statistical evidence strongly supports a conclusion that exchange rate movements can cause some migrants to substitute destinations.

  11. Whole-body voxel-based personalized dosimetry: Multiple voxel S-value approach for heterogeneous media with non-uniform activity distributions.

    Science.gov (United States)

    Lee, Min Sun; Kim, Joong Hyun; Paeng, Jin Chul; Kang, Keon Wook; Jeong, Jae Min; Lee, Dong Soo; Lee, Jae Sung

    2017-12-14

    Personalized dosimetry with high accuracy is becoming more important because of the growing interests in personalized medicine and targeted radionuclide therapy. Voxel-based dosimetry using dose point kernel or voxel S-value (VSV) convolution is available. However, these approaches do not consider medium heterogeneity. Here, we propose a new method for whole-body voxel-based personalized dosimetry for heterogeneous media with non-uniform activity distributions, which is referred to as the multiple VSV approach. Methods: The multiple numbers (N) of VSVs for media with different densities covering the whole-body density ranges were used instead of using only a single VSV for water. The VSVs were pre-calculated using GATE Monte Carlo simulation; those were convoluted with the time-integrated activity to generate density-specific dose maps. Computed tomography-based segmentation was conducted to generate binary maps for each density region. The final dose map was acquired by the summation of N segmented density-specific dose maps. We tested several sets of VSVs with different densities: N = 1 (single water VSV), 4, 6, 8, 10, and 20. To validate the proposed method, phantom and patient studies were conducted and compared with direct Monte Carlo, which was considered the ground truth. Finally, patient dosimetry (10 subjects) was conducted using the multiple VSV approach and compared with the single VSV and organ-based dosimetry approaches. Errors at the voxel- and organ-levels were reported for eight organs. Results: In the phantom and patient studies, the multiple VSV approach showed significant improvements regarding voxel-level errors, especially for the lung and bone regions. As N increased, voxel-level errors decreased, although some overestimations were observed at lung boundaries. In the case of multiple VSVs ( N = 8), we achieved voxel-level errors of 2.06%. In the dosimetry study, our proposed method showed much improved results compared to the single VSV and

  12. WE-FG-202-09: Voxel-Level Analysis of Adverse Treatment Response in Pediatric Patients Treated for Ependymoma with Passive Scattering Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Peeler, C [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX (United States); Mirkovic, D; Titt, U; Grosshans, D; Mohan, R [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: We identified patients treated for ependymoma with passive scattering proton therapy who subsequently developed treatment-related imaging changes on MRI. We sought to determine if there is any spatial correlation between imaged response, dose, and LET. Methods: A group of 14 patients treated for ependymoma were identified as having post-treatment MR imaging changes observable as T2-FLAIR hyperintensity with or without enhancement on T1 post-contrast sequences. MR images were registered with treatment planning CT images and regions of treatment-related change contoured by a practicing radiation oncologist. The contoured regions were identified as response with voxels represented as 1 while voxels within the brain outside of the response region were represented as 0. An in-house Monte Carlo system was used to recalculate treatment plans to obtain dose and LET information. Voxels were binned according to LET values in 0.3 keV µm{sup −1} bins. Dose and corresponding response value (0 or 1) for each voxel for a given LET bin were then plotted and fit with the Lyman-Kutcher-Burman dose response model to determine TD{sub 50} and m parameters for each LET value. Response parameters from all patients were then collated, and linear fits of the data were performed. Results: The response parameters TD50 and m both show trends with LET. Outliers were observed due to low numbers of response voxels in some cases. TD{sub 50} values decreased with LET while m increased with LET. The former result would indicate that for higher LET values, the dose is more effective, which is consistent with relative biological effectiveness (RBE) models for proton therapy. Conclusion: A novel method of voxel-level analysis of image biomarker-based adverse patient treatment response in proton therapy according to dose and LET has been presented. Fitted TD{sub 50} values show a decreasing trend with LET supporting the typical models of proton RBE. Funding provided by NIH Program Project

  13. A study of mental health literacy among North Korean refugees in South Korea.

    Science.gov (United States)

    Noh, Jin-Won; Kwon, Young Dae; Yu, Sieun; Park, Hyunchun; Woo, Jong-Min

    2015-01-01

    This study aimed to investigate North Korean refugees' knowledge of mental illnesses and treatments and analyze the factors affecting this knowledge. Subjects were selected via a snowball sampling method, and the survey outcomes of 152 North Korean refugee participants were analyzed. The factors affecting knowledge of mental illnesses were analyzed via a regression analysis by constructing a multivariate model with mental illness knowledge score as the dependent variable. The North Korean refugees' mental illness scores ranged from 3 to 24 points, with an average score of 13.0. Regarding the factors that influence mental illness knowledge, the subjects with South Korean spouses and those who had spent more time in South Korea had higher knowledge scores. Furthermore, the subjects who considered the mental health of North Korean refugees to be a serious issue revealed lower knowledge scores than those who did not believe it was a serious issue. The subjects who visit psychiatric clinics showed higher knowledge scores than those who do not. The South Korean subjects who had at least a college education exhibited higher scores than did those without advanced education. The subjects who are satisfied with life in South Korea manifested a higher mental illness knowledge score than those who are not. This study is significant as being the first study to ever measure and evaluate the level of North Korean refugees' knowledge of mental illnesses. In addition, the evaluations of North Korean refugees' mental illness knowledge and influencing factors while residing in South Korea created basic data that formed the foundation of an effort to enhance mental health literacy and provide proper mental health services. The results of this study can be utilized to solve mental health problems that might frequently occur during the unification process of North and South Korea in the future.

  14. A Study of Mental Health Literacy Among North Korean Refugees in South Korea

    Directory of Open Access Journals (Sweden)

    Jin-Won Noh

    2015-01-01

    Full Text Available Objectives: This study aimed to investigate North Korean refugees’ knowledge of mental illnesses and treatments and analyze the factors affecting this knowledge. Methods: Subjects were selected via a snowball sampling method, and the survey outcomes of 152 North Korean refugee participants were analyzed. The factors affecting knowledge of mental illnesses were analyzed via a regression analysis by constructing a multivariate model with mental illness knowledge score as the dependent variable. Results: The North Korean refugees’ mental illness scores ranged from 3 to 24 points, with an average score of 13.0. Regarding the factors that influence mental illness knowledge, the subjects with South Korean spouses and those who had spent more time in South Korea had higher knowledge scores. Furthermore, the subjects who considered the mental health of North Korean refugees to be a serious issue revealed lower knowledge scores than those who did not believe it was a serious issue. The subjects who visit psychiatric clinics showed higher knowledge scores than those who do not. The South Korean subjects who had at least a college education exhibited higher scores than did those without advanced education. The subjects who are satisfied with life in South Korea manifested a higher mental illness knowledge score than those who are not. Conclusions: This study is significant as being the first study to ever measure and evaluate the level of North Korean refugees’ knowledge of mental illnesses. In addition, the evaluations of North Korean refugees’ mental illness knowledge and influencing factors while residing in South Korea created basic data that formed the foundation of an effort to enhance mental health literacy and provide proper mental health services. The results of this study can be utilized to solve mental health problems that might frequently occur during the unification process of North and South Korea in the future.

  15. Obesity-risk behaviours and their associations with body mass index (BMI) in Korean American children.

    Science.gov (United States)

    Jang, Myoungock; Grey, Margaret; Sadler, Lois; Jeon, Sangchoon; Nam, Soohyun; Song, Hee-Jung; Whittemore, Robin

    2017-08-03

    To describe obesity-risk behaviours (diet, physical activity and sedentary behaviour) and examine the relationships of the obesity-risk behaviours with body mass index (BMI) in school-aged Korean American children. Korean American children have a risk of becoming overweight or obese and developing obesity-related complications; however, there is limited research about obesity-risk behaviours in Korean American children. A cross-sectional study. Obesity-risk behaviours of children were assessed with well-validated self-report questionnaires (i.e., Elementary-level School-based Nutrition Monitoring Questionnaire) from children and their mothers. Height and weight of children were measured. Data were analysed with bivariate and multivariate analyses using mixed effects models to incorporate the correlation within siblings. A total of 170 Korean American children (mean age 10.9 [2.0] years; 52.4% girls; mean BMI 19.3 [3.2]; 28.7% ≥85 percentiles) participated in the study. Only 38.3% of Korean American children met established recommendations of five fruits/vegetables per day; 56.5% met recommendations for more than 3 days per week of vigorous physical activity; and 40.8% met recommendations for obesity in Korean American children and initiate clinical interventions to improve obesity-risk behaviours, especially sedentary behaviour, in Korean American children. Clinical assessment and management of the risk of developing overweight and obesity as well as obesity-related behaviours are important to improve obesity-related complications in overall Korean Americans. © 2017 John Wiley & Sons Ltd.

  16. Bullying Involvement of Korean Children in Germany and in Korea

    Science.gov (United States)

    Bae, Hwa-ok

    2016-01-01

    This study compared bullying involvement of Korean or Korean-German children living in Germany with children in Korea, and examined children's perceptions of school environment associated with bullying involvement of the children. This study included 105 Korean or Korean-German children living in the Bayern State of Germany as the study sample and…

  17. Korean species of the genus Perlomyia Banks, 1906 (Plecoptera: Leuctridae).

    Science.gov (United States)

    Murányi, Dávid; Jeon, Mi Jeong; Hwang, Jeong Mi; Seo, Hong Yul

    2014-11-04

    Eight species of the genus Perlomyia (Plecoptera: Leuctridae) are reported from Korea, six are new records for the Korean Peninsula. Two species, known only as unassociated females are described under informal unnamed designations. Previous Korean records are discussed, taxonomic characters of the Korean specimens and Korean distribution are presented for these species. Zoogeographic notes on the Asian Perlomyia are also given.

  18. Intransigent Vowel-Consonant Position in Korean Dysgraphia: Evidence of Spatial-Constructive Representation

    Directory of Open Access Journals (Sweden)

    HyangHee Kim

    2007-01-01

    Full Text Available Dysgraphia due to a focal brain lesion can be characterized by substitution, transposition, deletion and/or addition errors of graphemes or strokes. However, those linguistic errors can be language-specific because the writing system of a given language may influence error patterns. We investigated a Korean stroke patient, a 57-year-old English teacher with dysgraphia both in Korean Han-geul (한글 and in English alphabet writings. The results of an experimental testing revealed transposition errors between a consonant and a vowel only in English but not in Korean writings. This austerity of vowel-consonant position may be attributed to a unique Korean writing system of a spatially well-formed syllabic configuration or block with consonant(s and a vowel. In light of a neuropsychological model of writing, which depicts a multi-level spelling and writing process, we suggest a spatial-constructional component of internal orthographic representations in Korean writing. This Korean graphemic configuration feature may be resistant to a focal, left cerebral damage, and thus, we also discuss our results in terms of cerebral lateralization of the writing processes.

  19. History of Korean gochu, gochujang, and kimchi

    Directory of Open Access Journals (Sweden)

    Dae Young Kwon

    2014-12-01

    Full Text Available The gochu (Korean red pepper that goes into Korean traditional fermented foods such as kimchi (fermented cabbage and gochujang (spicy red pepper paste should have a mild spiciness and its Scoville heat unit (the unit that measures spiciness is <1,000. The kimchi and gochujang that are fermented only with Korean gochu can be eaten. Kimchi and gochujang cannot be prepared even with cheongyangkochu (Scoville heat unit is approximately 3,000, which is a hybrid of Korean gochu and Thai gochu. When these foods are prepared with other spicier gochu, such as Thai pepper, Southern Asian red pepper, Central American red pepper, or Mexico's aji (which is 500 times spicier than Korean gochu, they will be too spicy to consume. Biologically, Korean gochu is different from the red peppers of Central American countries (such as Mexico and Colombia, Indonesia, India, and Thailand. Therefore, the statement that the Central American red pepper came to Korea during the Japanese invasion of Korea in 1592 is not true. We can refer to a research paper in the magazine “Nature” that Korea's gochu arrived at the Korean peninsula millions of years ago, having been spread by birds. It states that gochu has evolved for millions of years, therefore, we can infer that Korean gochu existed as a completely different variety. In addition, gochujang and kimchi can be made using gochu only, which proves that people in Korea cultivated gochu thousands of years ago and have been eating it since then. Furthermore, many old Korean documents support the fact that Koreans have been planting and harvesting gochu for the last 1,500 years.

  20. Subtype differentiation of renal tumors using voxel-based histogram analysis of intravoxel incoherent motion parameters.

    Science.gov (United States)

    Gaing, Byron; Sigmund, Eric E; Huang, William C; Babb, James S; Parikh, Nainesh S; Stoffel, David; Chandarana, Hersh

    2015-03-01

    The aim of this study was to determine if voxel-based histogram analysis of intravoxel incoherent motion imaging (IVIM) parameters can differentiate various subtypes of renal tumors, including benign and malignant lesions. A total of 44 patients with renal tumors who underwent surgery and had histopathology available were included in this Health Insurance Portability and Accountability Act-compliant, institutional review board-approved, single-institution prospective study. In addition to routine renal magnetic resonance imaging examination performed on a 1.5-T system, all patients were imaged with axial diffusion-weighted imaging using 8 b values (range, 0-800 s/mm). A biexponential model was fitted to the diffusion signal data using a segmented algorithm to extract the IVIM parameters perfusion fraction (fp), tissue diffusivity (Dt), and pseudodiffusivity (Dp) for each voxel. Mean and histogram measures of heterogeneity (standard deviation, skewness, and kurtosis) of IVIM parameters were correlated with pathology results of tumor subtype using unequal variance t tests to compare subtypes in terms of each measure. Correction for multiple comparisons was accomplished using the Tukey honestly significant difference procedure. A total of 44 renal tumors including 23 clear cell (ccRCC), 4 papillary (pRCC), 5 chromophobe, and 5 cystic renal cell carcinomas, as well as benign lesions, 4 oncocytomas (Onc) and 3 angiomyolipomas (AMLs), were included in our analysis. Mean IVIM parameters fp and Dt differentiated 8 of 15 pairs of renal tumors. Histogram analysis of IVIM parameters differentiated 9 of 15 subtype pairs. One subtype pair (ccRCC vs pRCC) was differentiated by mean analysis but not by histogram analysis. However, 2 other subtype pairs (AML vs Onc and ccRCC vs Onc) were differentiated by histogram distribution parameters exclusively. The standard deviation of Dt [σ(Dt)] differentiated ccRCC (0.362 ± 0.136 × 10 mm/s) from AML (0.199 ± 0.043 × 10 mm/s) (P = 0

  1. Preliminary investigation study of code of developed country for developing Korean fuel cycle code

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Ko, Won Il; Lee, Ho Hee; Cho, Dong Keun; Park, Chang Je

    2012-01-01

    In order to develop Korean fuel cycle code, the analyses has been performed with the fuel cycle codes which are used in advanced country. Also, recommendations were proposed for future development. The fuel cycle codes are AS FLOOWS: VISTA which has been developed by IAEA, DANESS code which developed by ANL and LISTO, and VISION developed by INL for the Advanced Fuel Cycle Initiative (AFCI) system analysis. The recommended items were proposed for software, program scheme, material flow model, isotope decay model, environmental impact analysis model, and economics analysis model. The described things will be used for development of Korean nuclear fuel cycle code in future

  2. NOTE: Development of modified voxel phantoms for the numerical dosimetric reconstruction of radiological accidents involving external sources: implementation in SESAME tool

    Science.gov (United States)

    Courageot, Estelle; Sayah, Rima; Huet, Christelle

    2010-05-01

    Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.

  3. A Study on the Radio Propagation in the Korean Ionosphere

    Directory of Open Access Journals (Sweden)

    Seok-Hee Bae

    1992-06-01

    Full Text Available The effects of the ionosphere on the radio wave propagation are scattering of radio waves, attenuation, angle error, ranging error, and time delay. If ionospheric conditions are suitable, the charged particles can remove energy from radio waves and thus attenuate the signal. Also, a radio wave traveling a path along which the electron density is not constant undergoes changes in direction, position and time of propagation. The present study is based on Korean ionospheric data obtained at the AnYong Radio Research Institute from Jan. 1985 through Oct. 1989. The data are used to simulate the Korean ionosphere following the Chapman law. The effects of the model ionosphere on the radio wave propagation, such as the angle, position error, time delay, and the attenuation, are studies for the various cases of the wave frequency and the altitude.

  4. Multimodal semantic quantity representations: further evidence from Korean Sign Language

    Directory of Open Access Journals (Sweden)

    Frank eDomahs

    2012-01-01

    Full Text Available Korean deaf signers performed a number comparison task on pairs of Arabic digits. In their RT profiles, the expected magnitude effect was systematically modified by properties of number signs in Korean Sign Language in a culture-specific way (not observed in hearing and deaf Germans or hearing Chinese. We conclude that finger-based quantity representations are automatically activated even in simple tasks with symbolic input although this may be irrelevant and even detrimental for task performance. These finger-based numerical representations are accessed in addition to another, more basic quantity system which is evidenced by the magnitude effect. In sum, these results are inconsistent with models assuming only one single amodal representation of numerical quantity.

  5. Multi-voxel decoding and the topography of maintained information during visual working memory

    Directory of Open Access Journals (Sweden)

    Sue-Hyun eLee

    2016-02-01

    Full Text Available The ability to maintain representations in the absence of external sensory stimulation, such as in working memory, is critical for guiding human behavior. Human functional brain imaging studies suggest that visual working memory can recruit a network of brain regions from visual to parietal to prefrontal cortex. In this review, we focus on the maintenance of representations during visual working memory and discuss factors determining the topography of those representations. In particular, we review recent studies employing multi-voxel pattern analysis that demonstrate decoding of the maintained content in visual cortex, providing support for a ‘sensory recruitment’ model of visual working memory. However, there is some evidence that maintained content can also be decoded in areas outside of visual cortex, including parietal and frontal cortex. We suggest that the ability to maintain representations during working memory is a general property of cortex, not restricted to specific areas, and argue that it is important to consider the nature of the information that must be maintained. Such information-content is critically determined by the task and the recruitment of specific regions during visual working memory will be both task- and stimulus-dependent. Thus, the common finding of maintained information in visual, but not parietal or prefrontal, cortex may be more of a reflection of the need to maintain specific types of visual information and not of a privileged role of visual cortex in maintenance.

  6. Voxel-based analysis of diffusion tensor indices in the brain in patients with Parkinson's disease

    International Nuclear Information System (INIS)

    Zhang Kaiyuan; Yu Chunshui; Zhang Yujin; Wu Xiaoli; Zhu Chaozhe; Chan Piu; Li Kuncheng

    2011-01-01

    Purpose: To investigate the abnormal diffusion in cerebral white matter and its relationship with the olfactory dysfunction in patients with Parkinson's disease (PD) through diffusion tensor imaging (DTI). Materials and methods: Diffusion tensor imaging of the cerebrum was performed in 25 patients with Parkinson's disease and 25 control subjects matched for age and sex. Differences in fractional anisotropy (FA) and mean diffusivity (MD) between these two groups were studied by voxel-based analysis of the DTI data. Correlations between diffusion indices and the olfactory function in PD patients were evaluated using the multiple regression model after controlling for the duration of the disease, Unified Parkinson's Disease Rating Sale (UPDRS), and age. Results: The damaged white and gray matter showed decreased FA or increased MD, localized bilaterally in the cerebellar and orbitofrontal cortex. In addition, in PD patients there was a positive correlation between FA values in the white matter of the left cerebellum and the thresholds of olfactory identification (TOI) and a negative correlation between MD values in the white matter of right cerebellum and the TOI. Conclusion: In patients with PD, there was disruption in the cerebellar white matter which may play an important role in the olfactory dysfunction in patients with Parkinson's disease.

  7. Anatomy of the Episodic Buffer: A Voxel-Based Morphometry Study in Patients with Dementia

    Directory of Open Access Journals (Sweden)

    M. Berlingeri

    2008-01-01

    Full Text Available In 2000 Baddeley proposed the existence of a new component of working memory, the episodic buffer, which should contribute to the on-line maintenance of integrated memory traces. The author assumed that this component should be critical for immediate recall of a short story that exceeds the capacity of the phonological store. Accordingly, patients with Alzheimer’s dementia (AD should suffer of a deficit of the episodic buffer when immediate recall of a short story is impossible. On the other hand, the episodic buffer should be somewhat preserved in such patients when some IR can occur (Baddeley and Wilson, 2002. We adopted this logic for a voxel-based morphometry study. We compared the distribution of grey-matter density of two such groups of AD patients with a group of age-matched controls. We found that both AD groups had a significant atrophy of the left mid-hippocampus; on the other hand, the anterior part of the hippocampus was significantly more atrophic in patients who were also impaired on the immediate prose recall task. Six out of ten patients with no immediate recall were spared at “central executive” tasks. Taken together our findings suggest that the left anterior hippocampus contributes to the episodic buffer of the revised working memory model. We also suggest that the episodic buffer is somewhat independent from the central executive component of working memory.

  8. Multi-Voxel Decoding and the Topography of Maintained Information During Visual Working Memory.

    Science.gov (United States)

    Lee, Sue-Hyun; Baker, Chris I

    2016-01-01

    The ability to maintain representations in the absence of external sensory stimulation, such as in working memory, is critical for guiding human behavior. Human functional brain imaging studies suggest that visual working memory can recruit a network of brain regions from visual to parietal to prefrontal cortex. In this review, we focus on the maintenance of representations during visual working memory and discuss factors determining the topography of those representations. In particular, we review recent studies employing multi-voxel pattern analysis (MVPA) that demonstrate decoding of the maintained content in visual cortex, providing support for a "sensory recruitment" model of visual working memory. However, there is some evidence that maintained content can also be decoded in areas outside of visual cortex, including parietal and frontal cortex. We suggest that the ability to maintain representations during working memory is a general property of cortex, not restricted to specific areas, and argue that it is important to consider the nature of the information that must be maintained. Such information-content is critically determined by the task and the recruitment of specific regions during visual working memory will be both task- and stimulus-dependent. Thus, the common finding of maintained information in visual, but not parietal or prefrontal, cortex may be more of a reflection of the need to maintain specific types of visual information and not of a privileged role of visual cortex in maintenance.

  9. Multi-Voxel Decoding and the Topography of Maintained Information During Visual Working Memory

    Science.gov (United States)

    Lee, Sue-Hyun; Baker, Chris I.

    2016-01-01

    The ability to maintain representations in the absence of external sensory stimulation, such as in working memory, is critical for guiding human behavior. Human functional brain imaging studies suggest that visual working memory can recruit a network of brain regions from visual to parietal to prefrontal cortex. In this review, we focus on the maintenance of representations during visual working memory and discuss factors determining the topography of those representations. In particular, we review recent studies employing multi-voxel pattern analysis (MVPA) that demonstrate decoding of the maintained content in visual cortex, providing support for a “sensory recruitment” model of visual working memory. However, there is some evidence that maintained content can also be decoded in areas outside of visual cortex, including parietal and frontal cortex. We suggest that the ability to maintain representations during working memory is a general property of cortex, not restricted to specific areas, and argue that it is important to consider the nature of the information that must be maintained. Such information-content is critically determined by the task and the recruitment of specific regions during visual working memory will be both task- and stimulus-dependent. Thus, the common finding of maintained information in visual, but not parietal or prefrontal, cortex may be more of a reflection of the need to maintain specific types of visual information and not of a privileged role of visual cortex in maintenance. PMID:26912997

  10. Application of average adult Japanese voxel phantoms to evaluation of photon specific absorbed fractions

    International Nuclear Information System (INIS)

    Sato, Kaoru; Manabe, Kentaro; Endo, Akira

    2012-01-01

    Average adult Japanese male (JM-103) and female (JF-103) voxel (volume pixel) phantoms newly constructed at the Japan Atomic Energy Agency (JAEA) have average characteristics of body sizes and organ masses in adult Japanese. In JM-103 and JF-103, several organs and tissues were newly modeled for dose assessments based on tissue weighting factors of the 2007 Recommendations of the International Commission on Radiological Protection(ICRP). In this study, SAFs for thyroid, stomach, lungs and lymphatic nodes of JM-103 and JF-103 phantoms were calculated, and were compared with those of other adult Japanese phantoms based on individual medical images. In most cases, differences in SAFs between JM-103, JF-103 and other phantoms were about several tens percent, and was mainly attributed to mass differences of organs, tissues and contents. Therefore, it was concluded that SAFs of JM-103 and JF-103 represent those of average adult Japanese and that the two phantoms are applied to dose assessment for average adult Japanese on the basis of the 2007 Recommendations. (author)

  11. Family functioning, resilience, and depression among North Korean refugees.

    Science.gov (United States)

    Nam, Boyoung; Kim, Jae Yop; DeVylder, Jordan E; Song, Ahyoung

    2016-11-30

    North Korean refugees in South Korea are at high risk of depression, but there are few studies exploring protective factors in this population. We hypothesized that family functioning (family adaptability and cohesion) and resilience would protect North Korean refugees from developing depressive symptoms. A subsample of 304 adult North Korean refugees drawn from the cross-sectional 2010 Nationwide Survey of Domestic Violence in South Korea was analyzed. Approximately 44% of respondents were identified as having depression, using scores on the Center for Epidemiological Studies Depression scale. In models capturing the full spectrum of depressive symptoms (continuous), family cohesion was significantly associated with depression, and the relationship was partially mediated by resilience. In models predicting clinical depression (dichotomous), resilience fully mediated the relationship between family cohesion and clinical depression. In contrast, family adaptability was not associated with depression or resilience in this sample. These findings suggest that assessing and enhancing family cohesion and resilience may be essential for professionals working with refugees, and that refugees without family support may be at particularly high risk for depression. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. VOXEL-BASED APPROACH FOR ESTIMATING URBAN TREE VOLUME FROM TERRESTRIAL LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    C. Vonderach

    2012-07-01

    Full Text Available The importance of single trees and the determination of related parameters has been recognized in recent years, e.g. for forest inventories or management. For urban areas an increasing interest in the data acquisition of trees can be observed concerning aspects like urban climate, CO2 balance, and environmental protection. Urban trees differ significantly from natural systems with regard to the site conditions (e.g. technogenic soils, contaminants, lower groundwater level, regular disturbance, climate (increased temperature, reduced humidity and species composition and arrangement (habitus and health status and therefore allometric relations cannot be transferred from natural sites to urban areas. To overcome this problem an extended approach was developed for a fast and non-destructive extraction of branch volume, DBH (diameter at breast height and height of single trees from point clouds of terrestrial laser scanning (TLS. For data acquisition, the trees were scanned with highest scan resolution from several (up to five positions located around the tree. The resulting point clouds (20 to 60 million points are analysed with an algorithm based on voxel (volume elements structure, leading to an appropriate data reduction. In a first step, two kinds of noise reduction are carried out: the elimination of isolated voxels as well as voxels with marginal point density. To obtain correct volume estimates, the voxels inside the stem and branches (interior voxels where voxels contain no laser points must be regarded. For this filling process, an easy and robust approach was developed based on a layer-wise (horizontal layers of the voxel structure intersection of four orthogonal viewing directions. However, this procedure also generates several erroneous "phantom" voxels, which have to be eliminated. For this purpose the previous approach was extended by a special region growing algorithm. In a final step the volume is determined layer-wise based on the

  13. S values at voxels level for 188Re and 90Y calculated with the MCNP-4C code

    International Nuclear Information System (INIS)

    Coca, M.A.; Torres, L.A.; Cornejo, N.; Martin, G.

    2008-01-01

    Full text: MIRD formalism at voxel level has been suggested as an optional methodology to perform internal radiation dosimetry calculation during internal radiation therapy in Nuclear Medicine. Voxel S values for Y 90 , 131 I, 32 P, 99m Tc and 89 Sr have been published to different sizes. Currently, 188 Re has been proposed as a promising radionuclide for therapy due to its physical features and availability from generators. The main objective of this work was to estimate the voxel S values for 188 Re at cubical geometry using the MCNP-4C code for the simulations of radiation transport and energy deposition. Mean absorbed dose to target voxels per radioactive decay in a source voxel were estimated and reported for 188 Re and Y 90 . A comparison of voxel S values computed with the MCNP code and the data reported in MIRD Pamphlet 17 for 90 Y was performed in order to evaluate our results. (author)

  14. Octree indexing of DICOM images for voxel number reduction and improvement of Monte Carlo simulation computing efficiency

    International Nuclear Information System (INIS)

    Hubert-Tremblay, Vincent; Archambault, Louis; Tubic, Dragan; Roy, Rene; Beaulieu, Luc

    2006-01-01

    The purpose of the present study is to introduce a compression algorithm for the CT (computed tomography) data used in Monte Carlo simulations. Performing simulations on the CT data implies large computational costs as well as large memory requirements since the number of voxels in such data reaches typically into hundreds of millions voxels. CT data, however, contain homogeneous regions which could be regrouped to form larger voxels without affecting the simulation's accuracy. Based on this property we propose a compression algorithm based on octrees: in homogeneous regions the algorithm replaces groups of voxels with a smaller number of larger voxels. This reduces the number of voxels while keeping the critical high-density gradient area. Results obtained using the present algorithm on both phantom and clinical data show that compression rates up to 75% are possible without losing the dosimetric accuracy of the simulation

  15. Medical images of patients in voxel structures in high resolution for Monte Carlo simulation

    International Nuclear Information System (INIS)

    Boia, Leonardo S.; Menezes, Artur F.; Silva, Ademir X.

    2011-01-01

    This work aims to present a computational process of conversion of tomographic and MRI medical images from patients in voxel structures to an input file, which will be manipulated in Monte Carlo Simulation code for tumor's radiotherapic treatments. The problem's scenario inherent to the patient is simulated by such process, using the volume element (voxel) as a unit of computational tracing. The head's voxel structure geometry has voxels with volumetric dimensions around 1 mm 3 and a population of millions, which helps - in that way, for a realistic simulation and a decrease in image's digital process techniques for adjustments and equalizations. With such additional data from the code, a more critical analysis can be developed in order to determine the volume of the tumor, and the protection, beside the patients' medical images were borrowed by Clinicas Oncologicas Integradas (COI/RJ), joined to the previous performed planning. In order to execute this computational process, SAPDI computational system is used in a digital image process for optimization of data, conversion program Scan2MCNP, which manipulates, processes, and converts the medical images into voxel structures to input files and the graphic visualizer Moritz for the verification of image's geometry placing. (author)

  16. A new registration method with voxel-matching technique for temporal subtraction images

    Science.gov (United States)

    Itai, Yoshinori; Kim, Hyoungseop; Ishikawa, Seiji; Katsuragawa, Shigehiko; Doi, Kunio

    2008-03-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes on medical images by removing most of normal structures. One of the important problems in temporal subtraction is that subtraction images commonly include artifacts created by slight differences in the size, shape, and/or location of anatomical structures. In this paper, we developed a new registration method with voxel-matching technique for substantially removing the subtraction artifacts on the temporal subtraction image obtained from multiple-detector computed tomography (MDCT). With this technique, the voxel value in a warped (or non-warped) previous image is replaced by a voxel value within a kernel, such as a small cube centered at a given location, which would be closest (identical or nearly equal) to the voxel value in the corresponding location in the current image. Our new method was examined on 16 clinical cases with MDCT images. Preliminary results indicated that interval changes on the subtraction images were enhanced considerably, with a substantial reduction of misregistration artifacts. The temporal subtraction images obtained by use of the voxel-matching technique would be very useful for radiologists in the detection of interval changes on MDCT images.

  17. Medical images of patients in voxel structures in high resolution for Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Boia, Leonardo S.; Menezes, Artur F.; Silva, Ademir X., E-mail: lboia@con.ufrj.b, E-mail: ademir@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear; Salmon Junior, Helio A. [Clinicas Oncologicas Integradas (COI), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    This work aims to present a computational process of conversion of tomographic and MRI medical images from patients in voxel structures to an input file, which will be manipulated in Monte Carlo Simulation code for tumor's radiotherapic treatments. The problem's scenario inherent to the patient is simulated by such process, using the volume element (voxel) as a unit of computational tracing. The head's voxel structure geometry has voxels with volumetric dimensions around 1 mm{sup 3} and a population of millions, which helps - in that way, for a realistic simulation and a decrease in image's digital process techniques for adjustments and equalizations. With such additional data from the code, a more critical analysis can be developed in order to determine the volume of the tumor, and the protection, beside the patients' medical images were borrowed by Clinicas Oncologicas Integradas (COI/RJ), joined to the previous performed planning. In order to execute this computational process, SAPDI computational system is used in a digital image process for optimization of data, conversion program Scan2MCNP, which manipulates, processes, and converts the medical images into voxel structures to input files and the graphic visualizer Moritz for the verification of image's geometry placing. (author)

  18. 3D dose distribution calculation in a voxelized human phantom by means of Monte Carlo method

    International Nuclear Information System (INIS)

    Abella, V.; Miro, R.; Juste, B.; Verdu, G.

    2010-01-01

    The aim of this work is to provide the reconstruction of a real human voxelized phantom by means of a MatLab program and the simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780 (MDS Nordion) 60 Co radiotherapy unit, by using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5. The project results in 3D dose mapping calculations inside the voxelized antropomorphic head phantom. The program provides the voxelization by first processing the CT slices; the process follows a two-dimensional pixel and material identification algorithm on each slice and three-dimensional interpolation in order to describe the phantom geometry via small cubic cells, resulting in an MCNP input deck format output. Dose rates are calculated by using the MCNP5 tool FMESH, superimposed mesh tally, which gives the track length estimation of the particle flux in units of particles/cm 2 . Furthermore, the particle flux is converted into dose by using the conversion coefficients extracted from the NIST Physical Reference Data. The voxelization using a three-dimensional interpolation technique in combination with the use of the FMESH tool of the MCNP Monte Carlo code offers an optimal simulation which results in 3D dose mapping calculations inside anthropomorphic phantoms. This tool is very useful in radiation treatment assessments, in which voxelized phantoms are widely utilized.

  19. Korean Reference HLW Disposal System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heui Joo; Lee, J. Y.; Kim, S. S. (and others)

    2008-03-15

    This report outlines the results related to the development of Korean Reference Disposal System for High-level radioactive wastes. The research has been supported around for 10 years through a long-term research plan by MOST. The reference disposal method was selected via the first stage of the research during which the technical guidelines for the geological disposal of HLW were determined too. At the second stage of the research, the conceptual design of the reference disposal system was made. For this purpose the characteristics of the reference spent fuels from PWR and CANDU reactors were specified, and the material and specifications of the canisters were determined in term of structural analysis and manufacturing capability in Korea. Also, the mechanical and chemical characteristics of the domestic Ca-bentonite were analyzed in order to supply the basic design parameters of the buffer. Based on these parameters the thermal and mechanical analysis of the near-field was carried out. Thermal-Hydraulic-Mechanical behavior of the disposal system was analyzed. The reference disposal system was proposed through the second year research. At the final third stage of the research, the Korean Reference disposal System including the engineered barrier, surface facilities, and underground facilities was proposed through the performance analysis of the disposal system.

  20. The North Korean nuclear dilemma

    International Nuclear Information System (INIS)

    Hecker, Siegfried S.

    2004-01-01

    The current nuclear crisis, the second one in ten years, erupted when North Korea expelled international nuclear inspectors in December 2002, then withdrew from the Nuclear Nonproliferation Treaty (NPT), and claimed to be building more nuclear weapons with the plutonium extracted from the spent fuel rods heretofore stored under international inspection. These actions were triggered by a disagreement over U.S. assertions that North Korea had violated the Agreed Framework (which froze the plutonium path to nuclear weapons to end the first crisis in 1994) by clandestinely developing uranium enrichment capabilities providing an alternative path to nuclear weapons. With Stanford University Professor John Lewis and three other Americans, I was allowed to visit the Yongbyon Nuclear Center on Jan. 8, 2004. We toured the 5 MWe reactor, the 50 MWe reactor construction site, the spent fuel pool storage building, and the radiochemical laboratory. We concluded that North Korea has restarted its 5 MWe reactor (which produces roughly 6 kg of plutonium annually), it removed the 8000 spent fuel rods that were previously stored under IAEA safeguards from the spent fuel pool, and that it most likely extracted the 25 to 30 kg of plutonium contained in these fuel rods. Although North Korean officials showed us what they claimed was their plutonium metal product from this reprocessing campaign, we were not able to conclude definitively that it was in fact plutonium metal and that it came from the most recent reprocessing campaign. Nevertheless, our North Korean hosts demonstrated that they had the capability, the facility and requisite capacity, and the technical expertise to produce plutonium metal. On the basis of our visit, we were not able to address the issue of whether or not North Korea had a 'deterrent' as claimed - that is, we were not able to conclude that North Korea can build a nuclear device and that it can integrate nuclear devices into suitable delivery systems. However

  1. Comparative study of SVM methods combined with voxel selection for object category classification on fMRI data.

    Science.gov (United States)

    Song, Sutao; Zhan, Zhichao; Long, Zhiying; Zhang, Jiacai; Yao, Li

    2011-02-16

    Support vector machine (SVM) has been widely used as accurate and reliable method to decipher brain patterns from functional MRI (fMRI) data. Previous studies have not found a clear benefit for non-linear (polynomial kernel) SVM versus linear one. Here, a more effective non-linear SVM using radial basis function (RBF) kernel is compared with linear SVM. Different from traditional studies which focused either merely on the evaluation of different types of SVM or the voxel selection methods, we aimed to investigate the overall performance of linear and RBF SVM for fMRI classification together with voxel selection schemes on classification accuracy and time-consuming. Six different voxel selection methods were employed to decide which voxels of fMRI data would be included in SVM classifiers with linear and RBF kernels in classifying 4-category objects. Then the overall performances of voxel selection and classification methods were compared. Results showed that: (1) Voxel selection had an important impact on the classification accuracy of the classifiers: in a relative low dimensional feature space, RBF SVM outperformed linear SVM significantly; in a relative high dimensional space, linear SVM performed better than its counterpart; (2) Considering the classification accuracy and time-consuming holistically, linear SVM with relative more voxels as features and RBF SVM with small set of voxels (after PCA) could achieve the better accuracy and cost shorter time. The present work provides the first empirical result of linear and RBF SVM in classification of fMRI data, combined with voxel selection methods. Based on the findings, if only classification accuracy was concerned, RBF SVM with appropriate small voxels and linear SVM with relative more voxels were two suggested solutions; if users concerned more about the computational time, RBF SVM with relative small set of voxels when part of the principal components were kept as features was a better choice.

  2. Multifractal analysis of the Korean agricultural market

    Science.gov (United States)

    Kim, Hongseok; Oh, Gabjin; Kim, Seunghwan

    2011-11-01

    We have studied the long-term memory effects of the Korean agricultural market using the detrended fluctuation analysis (DFA) method. In general, the return time series of various financial data, including stock indices, foreign exchange rates, and commodity prices, are uncorrelated in time, while the volatility time series are strongly correlated. However, we found that the return time series of Korean agricultural commodity prices are anti-correlated in time, while the volatility time series are correlated. The n-point correlations of time series were also examined, and it was found that a multifractal structure exists in Korean agricultural market prices.

  3. Ethnic Mobilization among Korean Dry Cleaners

    OpenAIRE

    Thomas, Ward F; Ong, Paul

    2015-01-01

    Korean immigrants in the U.S. rely heavily on ethnic resources to start small businesses.  Ethnic resources include business networks and knowledge, start-up capital, and access to labor power that are embedded in networks of family, friends, and co-ethnics.  This paper shows how Korean dry cleaners in Southern California used ethnic resources to mobilize in response to an environmental policy initiated by the South Coast Air Quality Management District (AQMD).  While Korean immigrants used e...

  4. Comparison of classification methods for voxel-based prediction of acute ischemic stroke outcome following intra-arterial intervention

    Science.gov (United States)

    Winder, Anthony J.; Siemonsen, Susanne; Flottmann, Fabian; Fiehler, Jens; Forkert, Nils D.

    2017-03-01

    Voxel-based tissue outcome prediction in acute ischemic stroke patients is highly relevant for both clinical routine and research. Previous research has shown that features extracted from baseline multi-parametric MRI datasets have a high predictive value and can be used for the training of classifiers, which can generate tissue outcome predictions for both intravenous and conservative treatments. However, with the recent advent and popularization of intra-arterial thrombectomy treatment, novel research specifically addressing the utility of predictive classi- fiers for thrombectomy intervention is necessary for a holistic understanding of current stroke treatment options. The aim of this work was to develop three clinically viable tissue outcome prediction models using approximate nearest-neighbor, generalized linear model, and random decision forest approaches and to evaluate the accuracy of predicting tissue outcome after intra-arterial treatment. Therefore, the three machine learning models were trained, evaluated, and compared using datasets of 42 acute ischemic stroke patients treated with intra-arterial thrombectomy. Classifier training utilized eight voxel-based features extracted from baseline MRI datasets and five global features. Evaluation of classifier-based predictions was performed via comparison to the known tissue outcome, which was determined in follow-up imaging, using the Dice coefficient and leave-on-patient-out cross validation. The random decision forest prediction model led to the best tissue outcome predictions with a mean Dice coefficient of 0.37. The approximate nearest-neighbor and generalized linear model performed equally suboptimally with average Dice coefficients of 0.28 and 0.27 respectively, suggesting that both non-linearity and machine learning are desirable properties of a classifier well-suited to the intra-arterial tissue outcome prediction problem.

  5. S values at voxels level for 188Re and 90Y calculated with the MCNP-4C code

    International Nuclear Information System (INIS)

    Coca Perez, Marco Antonio; Torres Aroche, Leonel Alberto; Cornejo, Nestor; Martin Hernandez, Guido

    2003-01-01

    The main objective of this work was estimate the voxels S values for 188 Re at cubical geometry using the MCNP-4C code for the simulation of radiation transport and energy deposition. Mean absorbed dose to target voxels per radioactive decay in a source voxels were estimated and reported for 188 Re and Y 90 . A comparison of voxels S values computed with the MCNP code the data reported in MIRD pamphlet 17 for 90 Y was performed in order to evaluate our results

  6. Treating voxel geometries in radiation protection dosimetry with a patched version of the Monte Carlo codes MCNP and MCNPX.

    Science.gov (United States)

    Burn, K W; Daffara, C; Gualdrini, G; Pierantoni, M; Ferrari, P

    2007-01-01

    The question of Monte Carlo simulation of radiation transport in voxel geometries is addressed. Patched versions of the MCNP and MCNPX codes are developed aimed at transporting radiation both in the standard geometry mode and in the voxel geometry treatment. The patched code reads an unformatted FORTRAN file derived from DICOM format data and uses special subroutines to handle voxel-to-voxel radiation transport. The various phases of the development of the methodology are discussed together with the new input options. Examples are given of employment of the code in internal and external dosimetry and comparisons with results from other groups are reported.

  7. Shifting from region of interest (ROI) to voxel-based analysis in human brain mapping

    International Nuclear Information System (INIS)

    Astrakas, Loukas G.; Argyropoulou, Maria I.

    2010-01-01

    Current clinical studies involve multidimensional high-resolution images containing an overwhelming amount of structural and functional information. The analysis of such a wealth of information is becoming increasingly difficult yet necessary in order to improve diagnosis, treatment and healthcare. Voxel-wise analysis is a class of modern methods of image processing in the medical field with increased popularity. It has replaced manual region of interest (ROI) analysis and has provided tools to make statistical inferences at voxel level. The introduction of voxel-based analysis software in all modern commercial scanners allows clinical use of these techniques. This review will explain the main principles, advantages and disadvantages behind these methods of image analysis. (orig.)

  8. The role of Hallyu as pop culture in the creation and dissemination of the contemporary korean woman's image

    Directory of Open Access Journals (Sweden)

    Nayelli López Rocha

    2016-02-01

    Full Text Available Categorized as a cultural phenomenon by its international scope and for being a diffuser and disseminator element of Korean culture during the last decade, this movement without precedents called "Hallyu" or "Korean wave" has been instrumental in the promotion and dissemination of Korea’s image in many countries around the world. Due to the importance that this cultural flow has achieved in the past ten years, its definition has been taking and integrating, during its development process, different characteristics. Nowadays, K-pop or pop music has become the most popular element contained within the called Korean pop culture that, in turn, becomes the country’s image to other latitudes. In this work the Hallyu is defined as a socio-cultural phenomenon of hybrid characteristics which contains elements of Korean traditional and modern culture, as elements of the socalled global culture, mixing it in a peculiar way in the local context redefining it as authentically Korean. This project specifically explores how, through Hallyu, the image of modern Korean woman has been modeled by certain characteristics, reaffirming an idea of women which do not necessarily represent the majority of them in this country. In this way, it is analyzed; the construction of the image of Korean women in its current society to understand in which circumstances this image of contemporary woman is created and recreated, establishing an image of being woman to recipients of Hallyu.

  9. Factors Affecting Job Satisfaction of Immigrant Korean Nurses.

    Science.gov (United States)

    An, Ji-Young; Cha, Sunkyung; Moon, Hyunjung; Ruggiero, Jeanne S; Jang, Haeran

    2016-03-01

    An increasing number of foreign-born nurses are working in the United States. Nurses' job satisfaction is a critical issue for quality patient care. The purpose of this study was to examine factors affecting the job satisfaction of immigrant Korean nurses. We used a cross-sectional mailed survey design. A convenience sample (n = 105) of members of the Greater New York Korean Nurses Association currently working or had previously worked in the United States completed the questionnaires. We used hierarchical regression to test the effects of acculturation and life satisfaction on job satisfaction. Most participants were female (n = 98, 93.3%) aged 27 to 70 years (mean = 52.27 years, SD = 10.67). In the regression model, life satisfaction, self-esteem, and perceived stress predicted job satisfaction (F = 5.127, p job satisfaction. U.S. nurses need to gain insight into factors influencing job satisfaction in Korean nurses to promote retention and quality care. © The Author(s) 2014.

  10. Coffee Consumption and the Risk of Obesity in Korean Women.

    Science.gov (United States)

    Lee, Jeonghee; Kim, Hye Young; Kim, Jeongseon

    2017-12-08

    Instant coffee mixes that contain sugar and non-dairy creamer account for 80-90% of the total coffee market in Korea. The objective of this study was to investigate the relationship between coffee consumption and obesity in Korean women. We included 5995 women who participated in a health screening examination at the Korean National Cancer Center between 2007 and 2016. Daily coffee consumption and the use of sugar and creamer in coffee was evaluated using a 106-item food frequency questionnaire. Obesity was assessed by body mass index (BMI), and abdominal obesity was assessed by waist circumference (WC). A multiple logistic regression model was used to calculate the odds ratio (OR) of obesity according to coffee consumption. After multivariate adjustment, high coffee consumption was positively associated with obesity as measured by BMI (≥3 cups vs. no drinks, OR = 2.52; 95% confidence interval (CI) = 1.91-3.34; p for the trend coffee consumption and obesity prevalence was not altered by menopause. The amount of coffee with additives consumed per day by Korean women was positively correlated with the prevalence of obesity, but causation cannot be determined due to the cross-sectional nature of the study design. The mechanism underlying the observed relationship is yet to be elucidated.

  11. Metabolic Risk Profile and Cancer in Korean Men and Women.

    Science.gov (United States)

    Ko, Seulki; Yoon, Seok-Jun; Kim, Dongwoo; Kim, A-Rim; Kim, Eun-Jung; Seo, Hye-Young

    2016-05-01

    Metabolic syndrome is a cluster of risk factors for type 2 diabetes mellitus and cardiovascular disease. Associations between metabolic syndrome and several types of cancer have recently been documented. We analyzed the sample cohort data from the Korean National Health Insurance Service from 2002, with a follow-up period extending to 2013. The cohort data included 99 565 individuals who participated in the health examination program and whose data were therefore present in the cohort database. The metabolic risk profile of each participant was assessed based on obesity, high serum glucose and total cholesterol levels, and high blood pressure. The occurrence of cancer was identified using Korean National Health Insurance claims data. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated using Cox proportional hazards models, adjusting for age group, smoking status, alcohol intake, and regular exercise. A total of 5937 cases of cancer occurred during a mean follow-up period of 10.4 years. In men with a high-risk metabolic profile, the risk of colon cancer was elevated (HR, 1.40; 95% CI, 1.14 to 1.71). In women, a high-risk metabolic profile was associated with a significantly increased risk of gallbladder and biliary tract cancer (HR, 2.05; 95% CI, 1.24 to 3.42). Non-significantly increased risks were observed in men for pharynx, larynx, rectum, and kidney cancer, and in women for colon, liver, breast, and ovarian cancer. The findings of this study support the previously suggested association between metabolic syndrome and the risk of several cancers. A high-risk metabolic profile may be an important risk factor for colon cancer in Korean men and gallbladder and biliary tract cancer in Korean women.

  12. The impact of sample size on the reproducibility of voxel-based lesion-deficit mappings.

    Science.gov (United States)

    Lorca-Puls, Diego L; Gajardo-Vidal, Andrea; White, Jitrachote; Seghier, Mohamed L; Leff, Alexander P; Green, David W; Crinion, Jenny T; Ludersdorfer, Philipp; Hope, Thomas M H; Bowman, Howard; Price, Cathy J

    2018-07-01

    This study investigated how sample size affects the reproducibility of findings from univariate voxel-based lesion-deficit analyses (e.g., voxel-based lesion-symptom mapping and voxel-based morphometry). Our effect of interest was the strength of the mapping between brain damage and speech articulation difficulties, as measured in terms of the proportion of variance explained. First, we identified a region of interest by searching on a voxel-by-voxel basis for brain areas where greater lesion load was associated with poorer speech articulation using a large sample of 360 right-handed English-speaking stroke survivors. We then randomly drew thousands of bootstrap samples from this data set that included either 30, 60, 90, 120, 180, or 360 patients. For each resample, we recorded effect size estimates and p values after conducting exactly the same lesion-deficit analysis within the previously identified region of interest and holding all procedures constant. The results show (1) how often small effect sizes in a heterogeneous population fail to be detected; (2) how effect size and its statistical significance varies with sample size; (3) how low-powered studies (due to small sample sizes) can greatly over-estimate as well as under-estimate effect sizes; and (4) how large sample sizes (N ≥ 90) can yield highly significant p values even when effect sizes are so small that they become trivial in practical terms. The implications of these findings for interpreting the results from univariate voxel-based lesion-deficit analyses are discussed. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. Black and Korean: Racialized Development and the Korean American Subject in Korean/American Fiction

    Directory of Open Access Journals (Sweden)

    Jeehyun Lim

    2013-09-01

    Full Text Available This article examines the representation of the encounters and exchanges between Asian and black Americans in Sŏk-kyŏng Kang’s “Days and Dreams,” Heinz Insu Fenkl’s Memories of My Ghost Brother, and Chang-rae Lee’s A Gesture Life. While one popular mode of looking at Asian and black Americans relationally in the postwar era is to compare the success of Asian American assimilation to the failure of black Americans, Lim argues that such a mode of comparison cannot account for the ways in which Asian American racialization takes places within the global currents of militarism and migration. Against the popular view that attributes Asian American success to cultural difference, Lim relies on political scientist Claire Kim’s understanding of culture as something that is constructed in the process of racialization to explore how the above texts imagine the terms of comparative racialization between black and Asian Americans. The black-Korean encounters in these texts demand a heuristic of comparative racialization that goes beyond the discussion of the black-white binary as a national construct and seeks the reification and modification of this racial frame as it travels along the routes of US military and economic incursions in the Pacific. Lim suggests that the literary imagining of black-Korean encounters across the Pacific illustrates race and racialization as effects of a regime of economic development that is supported by military aggression.

  14. Investment incentives in the Korean electricity market

    International Nuclear Information System (INIS)

    Park, Jung-Yeon; Ahn, Nam-Sung; Yoon, Yong-Beum; Koh, Kyung-Ho; Bunn, Derek W.

    2007-01-01

    This paper develops a model-based analysis of the effects of various capacity incentive systems on new investment in the Korean electricity market. The restructuring process in Korea allocated power generation to six firms, competing within a wholesale market, albeit strictly on a cost basis. Because of this cost-based pool, capacity payments were also introduced to encourage new investment. However, it is an open question whether the current fixed capacity payment scheme is enough to secure resource adequacy, and consideration is being given to alternative mechanisms such as the use of LOLP. Using a detailed market simulation model, based on system dynamics, we compare these approaches in terms of how they may influence the investors' decisions and thereby determine the system reserve margin. The simulation results suggest that there may be serious problems in staying with the current fixed capacity payments in order to achieve resource adequacy. In contrast, an LOLP-based capacity mechanism may, in the longer term, increase the reserve margin compared with a fixed capacity payment. More generally, this paper indicates how crucial the effective modeling of the investment behavior of the independent power producers is for adequate policy support, even if they only constitute a fringe in a substantially centrally influenced market

  15. Influence of evanescent waves on the voxel profile in multipulse multiphoton polymerization nanofabrication

    International Nuclear Information System (INIS)

    Li Wei; Cao Tianxiang; Zhai Zhaohui; Yu Xuanyi; Zhang Xinzheng; Xu Jingjun

    2013-01-01

    The relationship between the profile of the structures obtained by multiphoton polymerization and the optical parameters of nanofabrication systems has been studied theoretically for a multipulse scheme. We find that the profile of sub-wavelength structures is greatly affected by the evanescent waves affect. Not only is the photocured polymer voxel affected by the beam profile, but the beam propagation behavior is influenced by the photocured polymer voxel. This gives us a new view of matter–light interactions in multipulse polymerization process, which is useful to the accurate control of the nanofabrication profile and the selection of new nanofabrication materials. (paper)

  16. High performance cone-beam spiral backprojection with voxel-specific weighting

    International Nuclear Information System (INIS)

    Steckmann, Sven; Knaup, Michael; Kachelriess, Marc

    2009-01-01

    Cone-beam spiral backprojection is computationally highly demanding. At first sight, the backprojection requirements are similar to those of cone-beam backprojection from circular scans such as it is performed in the widely used Feldkamp algorithm. However, there is an additional complication: the illumination of each voxel, i.e. the range of angles the voxel is seen by the x-ray cone, is a complex function of the voxel position. In general, one needs to multiply a voxel-specific weight w(x, y, z, α) prior to adding a projection from angle α to a voxel at position x, y, z. Often, the weight function has no analytically closed form and must be numerically determined. Storage of the weights is prohibitive since the amount of memory required equals the number of voxels per spiral rotation times the number of projections a voxel receives contributions and therefore is in the order of up to 10 12 floating point values for typical spiral scans. We propose a new algorithm that combines the spiral symmetry with the ability of today's 64 bit operating systems to store large amounts of precomputed weights, even above the 4 GB limit. Our trick is to backproject into slices that are rotated in the same manner as the spiral trajectory rotates. Using the spiral symmetry in this way allows one to exploit data-level paralellism and thereby to achieve a very high level of vectorization. An additional postprocessing step rotates these slices back to normal images. Our new backprojection algorithm achieves up to 17 giga voxel updates per second on our systems that are equipped with four standard Intel X7460 hexa core CPUs (Intel Xeon 7300 platform, 2.66 GHz, Intel Corporation). This equals the reconstruction of 344 images per second assuming that each slice consists of 512 x 512 pixels and receives contributions from 512 projections. Thereby, it is an order of magnitude faster than a highly optimized code that does not make use of the spiral symmetry. In its present version, the

  17. High performance cone-beam spiral backprojection with voxel-specific weighting

    Science.gov (United States)

    Steckmann, Sven; Knaup, Michael; Kachelrieß, Marc

    2009-06-01

    Cone-beam spiral backprojection is computationally highly demanding. At first sight, the backprojection requirements are similar to those of cone-beam backprojection from circular scans such as it is performed in the widely used Feldkamp algorithm. However, there is an additional complication: the illumination of each voxel, i.e. the range of angles the voxel is seen by the x-ray cone, is a complex function of the voxel position. In general, one needs to multiply a voxel-specific weight w(x, y, z, α) prior to adding a projection from angle α to a voxel at position x, y, z. Often, the weight function has no analytically closed form and must be numerically determined. Storage of the weights is prohibitive since the amount of memory required equals the number of voxels per spiral rotation times the number of projections a voxel receives contributions and therefore is in the order of up to 1012 floating point values for typical spiral scans. We propose a new algorithm that combines the spiral symmetry with the ability of today's 64 bit operating systems to store large amounts of precomputed weights, even above the 4 GB limit. Our trick is to backproject into slices that are rotated in the same manner as the spiral trajectory rotates. Using the spiral symmetry in this way allows one to exploit data-level paralellism and thereby to achieve a very high level of vectorization. An additional postprocessing step rotates these slices back to normal images. Our new backprojection algorithm achieves up to 17 giga voxel updates per second on our systems that are equipped with four standard Intel X7460 hexa core CPUs (Intel Xeon 7300 platform, 2.66 GHz, Intel Corporation). This equals the reconstruction of 344 images per second assuming that each slice consists of 512 × 512 pixels and receives contributions from 512 projections. Thereby, it is an order of magnitude faster than a highly optimized code that does not make use of the spiral symmetry. In its present version, the

  18. Hitchhiker'S Guide to Voxel Segmentation for Partial Volume Correction of in Vivo Magnetic Resonance Spectroscopy

    Directory of Open Access Journals (Sweden)

    Scott Quadrelli

    2016-01-01

    Full Text Available Partial volume effects have the potential to cause inaccuracies when quantifying metabolites using proton magnetic resonance spectroscopy (MRS. In order to correct for cerebrospinal fluid content, a spectroscopic voxel needs to be segmented according to different tissue contents. This article aims to detail how automated partial volume segmentation can be undertaken and provides a software framework for researchers to develop their own tools. While many studies have detailed the impact of partial volume correction on proton magnetic resonance spectroscopy quantification, there is a paucity of literature explaining how voxel segmentation can be achieved using freely available neuroimaging packages.

  19. The internationalization of the Korean radiological society

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; Kim, Seung Hyup; Han, Man Chung; Kim, Young Goo; Kim, Kun Sang

    1995-01-01

    Toward the beginning of the twenty-first century, the world experiences the dramatic changes in politics, economics and culture, and it is evident that the Korean medical field will not be able to survive provided it doesn't prepare ourselves to adapt to those changes. The Korean Medical Society held a forum for the active operation of the medical society, inviting several leading affiliated societies, to meet the needs of the times. This review describes the summary of the presentation that the authors made on behalf of the Korean Radiological Society in the forum, including the organization, current status of academic activity, current status of international communication, and problems encountered in the internationalization of the Korean Radiological Society

  20. Sustainment Stocks for the Korean Theater

    National Research Council Canada - National Science Library

    St

    1998-01-01

    .... This study concludes that the Army intends to provide theater Class VII combat loss replacements, in the Korean theater, in the early stage of conflict or war from Army Pre-positioned Stocks-Sustainment 4 (APS-S 4...

  1. The Role of China in Korean Unification

    National Research Council Canada - National Science Library

    Son, Dae

    2003-01-01

    ...) was the Republic of Korea (ROK)'s primary enemy state, and the United States became the ROK's only military alliance state, particularly due to their intervention in the Korean War in the Cold War era, the PRC, coupled...

  2. The Korean nuclear ODA policy development

    International Nuclear Information System (INIS)

    Lee, Seung Hyun; Min, Kim Yoo; Park, Young Il

    2012-01-01

    Korean nuclear Official Development Assistance (ODA) is established with support from institutes such as the Korea International Cooperation Agency (KOICA) and the Korea Atomic Energy Research Institute (KAERI). KOICA's grant aid mainly made through the activities including IAEA's training program, and KAERI currently runs the inter-regional education and training cooperation called Asian Network for Education in Nuclear Technology(ANENT) which aimed to achieve the goal of encouraging web based education training network via cooperation with IAEA. Yet now these programs are focusing more on assisting nuclear infrastructure rather than highlighting nuclear education and training. This paper aims to, first, do a self-evaluation about the Korean ODA policy; second, to study the transition of the international nuclear atmosphere; and third, by apprehending the trend of the subjects of Korean nuclear ODA policy, to discuss the overall appropriate trajectory of Korean nuclear ODA

  3. North Korean Crime-for-Profit Activities

    National Research Council Canada - National Science Library

    Perl, Raphael; Nanto, Dick K

    2007-01-01

    ... and counterfeiting of cigarettes expanding. Overall, the reported scale of this activity is significant and arguably provides important foreign currency resources to the military-oriented North Korean state...

  4. [Emotional display rules of Japanese and Koreans].

    Science.gov (United States)

    Lee, Ye-jin; Matsumoto, Yoshiyuki

    2011-12-01

    Hypothetical stories designed to arouse feelings of happiness, sadness, or anger were presented to Japanese (n = 310) and Koreans (n = 286) university students. They were asked to rate the intensity of the emotion experienced, and to select the corresponding facial expression to display in an individual situation and in a social situation. Analyses of covariance were conducted on the rating scores of facial expression using the intensities of emotion as the covariance, except for happiness where the within-class regression coefficients were not homogeneous. The results showed that Japanese and Koreans shared the emotional display rules about the expressions of emotions in individual situations more than in social situations. Japanese thought that they should suppress emotions more than Koreans did. Moreover, the differences in facial expressions between Japanese and Koreans were greater in the individual situations than in the social situations.

  5. The Economic Implications of Korean Reunification

    National Research Council Canada - National Science Library

    O'Shaughnessy, Karlynn

    2003-01-01

    ...) and the Democratic People's Republic of Korea (DPRK). The eventual reunification of the Korean peninsula will offer many challenges for the two countries, as well as for every entity with interests in the region...

  6. Right Brodmann area 18 predicts tremor arrest after Vim radiosurgery: a voxel-based morphometry study.

    Science.gov (United States)

    Tuleasca, Constantin; Witjas, Tatiana; Van de Ville, Dimitri; Najdenovska, Elena; Verger, Antoine; Girard, Nadine; Champoudry, Jerome; Thiran, Jean-Philippe; Cuadra, Meritxell Bach; Levivier, Marc; Guedj, Eric; Régis, Jean

    2018-03-01

    Drug-resistant essential tremor (ET) can benefit from open standard stereotactic procedures, such as deep-brain stimulation or radiofrequency thalamotomy. Non-surgical candidates can be offered either high-focused ultrasound (HIFU) or radiosurgery (RS). All procedures aim to target the same thalamic site, the ventro-intermediate nucleus (e.g., Vim). The mechanisms by which tremor stops after Vim RS or HIFU remain unknown. We used voxel-based morphometry (VBM) on pretherapeutic neuroimaging data and assessed which anatomical site would best correlate with tremor arrest 1 year after Vim RS. Fifty-two patients (30 male, 22 female; mean age 71.6 years, range 49-82) with right-sided ET benefited from left unilateral Vim RS in Marseille, France. Targeting was performed in a uniform manner, using 130 Gy and a single 4-mm collimator. Neurological (pretherapeutic and 1 year after) and neuroimaging (baseline) assessments were completed. Tremor score on the treated hand (TSTH) at 1 year after Vim RS was included in a statistical parametric mapping analysis of variance (ANOVA) model as a continuous variable with pretherapeutic neuroimaging data. Pretherapeutic gray matter density (GMD) was further correlated with TSTH improvement. No a priori hypothesis was used in the statistical model. The only statistically significant region was right Brodmann area (BA) 18 (visual association area V2, p = 0.05, cluster size K c  = 71). Higher baseline GMD correlated with better TSTH improvement at 1 year after Vim RS (Spearman's rank correlation coefficient = 0.002). Routine baseline structural neuroimaging predicts TSTH improvement 1 year after Vim RS. The relevant anatomical area is the right visual association cortex (BA 18, V2). The question whether visual areas should be included in the targeting remains open.

  7. Voxel-based morphometry analyses of in-vivo MRI in the aging mouse lemur primate

    Directory of Open Access Journals (Sweden)

    Stephen John Sawiak

    2014-05-01

    Full Text Available Cerebral atrophy is one of the most widely brain alterations associated to aging. A clear relationship has been established between age-associated cognitive impairments and cerebral atrophy. The mouse lemur (Microcebus murinus is a small primate used as a model of age-related neurodegenerative processes. It is the first nonhuman primate in which cerebral atrophy has been correlated with cognitive deficits. Previous studies of cerebral atrophy in this model were based on time consuming manual delineation or measurement of selected brain regions from magnetic resonance images (MRI. These measures could not be used to analyse regions that cannot be easily outlined such as the nucleus basalis of Meynert or the subiculum. In humans, morphometric assessment of structural changes with age is generally performed with automated procedures such as voxel-based morphometry (VBM. The objective of our work was to perform user-independent assessment of age-related morphological changes in the whole brain of large mouse lemur populations thanks to VBM. The study was based on the SPMMouse toolbox of SPM 8 and involved thirty mouse lemurs aged from 1.9 to 11.3 years. The automatic method revealed for the first time atrophy in regions where manual delineation is prohibitive (nucleus basalis of Meynert, subiculum, prepiriform cortex, Brodmann areas 13-16, hypothalamus, putamen, thalamus, corpus callosum. Some of these regions are described as particularly sensitive to age-associated alterations in humans. The method revealed also age-associated atrophy in cortical regions (cingulate, occipital, parietal, nucleus septalis, and the caudate. Manual measures performed in some of these regions were in good agreement with results from automatic measures. The templates generated in this study as well as the toolbox for SPM8 can be downloaded. These tools will be valuable for future evaluation of various treatments that are tested to modulate cerebral aging in lemurs.

  8. Hormone Replacement Therapy and Risk of Breast Cancer in Korean Women: A Quantitative Systematic Review

    Directory of Open Access Journals (Sweden)

    Jong-Myon Bae

    2015-09-01

    Full Text Available Objectives: The epidemiological characteristics of breast cancer incidence by age group in Korean women are unique. This systematic review aimed to investigate the association between hormone replacement therapy (HRT and breast cancer risk in Korean women. Methods: We searched electronic databases such as KoreaMed, KMbase, KISS, and RISS4U as well as PubMed for publications on Korean breast cancer patients. We also conducted manual searching based on references and citations in potential papers. All of the analytically epidemiologic studies that obtained individual data on HRT exposure and breast cancer occurrence in Korean women were selected. We restricted the inclusion of case-control studies to those that included age-matched controls. Estimates of summary odds ratio (SOR with 95% confidence intervals (CIs were calculated using random effect models. Results: One cohort and five case-control studies were finally selected. Based on the heterogeneity that existed among the six studies (I-squared=70.2%, a random effect model was applied. The summary effect size of HRT history from the six articles indicated no statistical significance in breast cancer risk (SOR, 0.983; 95% CI, 0.620 to 1.556. Conclusions: These facts support no significant effect of HRT history in the risk of breast cancer in Korean women. It is necessary to conduct a pooled analysis.

  9. Women Workforce in the Korean Context

    OpenAIRE

    Lee, Yeonu

    2017-01-01

    The social participation of women workforce in the labour market is now more prevalent than ever, however the promotion opportunities for women employees are limited compared to men in the Korean context. The article explores the impact of the Confucian tradition on women employees and as a result the traditional value causes difficulties for women employees to gain promotion than men in organisations. Also this article discusses why Korean women need to overcome the ‘glass ceiling’ more comp...

  10. Korean Clinic Based Outcome Measure Studies

    OpenAIRE

    Jongbae Park

    2003-01-01

    Background: Evidence based medicine has become main tools for medical practice. However, conducting a highly ranked in the evidence hierarchy pyramid is not easy or feasible at all times and places. There remains a room for descriptive clinical outcome measure studies with admitting the limit of the intepretation. Aims: Presents three Korean clinic based outcome measure studies with a view to encouraging Korean clinicians to conduct similar studies. Methods: Three studies are presented...

  11. Micro-computed tomography pore-scale study of flow in porous media: Effect of voxel resolution

    Science.gov (United States)

    Shah, S. M.; Gray, F.; Crawshaw, J. P.; Boek, E. S.

    2016-09-01

    A fundamental understanding of flow in porous media at the pore-scale is necessary to be able to upscale average displacement processes from core to reservoir scale. The study of fluid flow in porous media at the pore-scale consists of two key procedures: Imaging - reconstruction of three-dimensional (3D) pore space images; and modelling such as with single and two-phase flow simulations with Lattice-Boltzmann (LB) or Pore-Network (PN) Modelling. Here we analyse pore-scale results to predict petrophysical properties such as porosity, single-phase permeability and multi-phase properties at different length scales. The fundamental issue is to understand the image resolution dependency of transport properties, in order to up-scale the flow physics from pore to core scale. In this work, we use a high resolution micro-computed tomography (micro-CT) scanner to image and reconstruct three dimensional pore-scale images of five sandstones (Bentheimer, Berea, Clashach, Doddington and Stainton) and five complex carbonates (Ketton, Estaillades, Middle Eastern sample 3, Middle Eastern sample 5 and Indiana Limestone 1) at four different voxel resolutions (4.4 μm, 6.2 μm, 8.3 μm and 10.2 μm), scanning the same physical field of view. Implementing three phase segmentation (macro-pore phase, intermediate phase and grain phase) on pore-scale images helps to understand the importance of connected macro-porosity in the fluid flow for the samples studied. We then compute the petrophysical properties for all the samples using PN and LB simulations in order to study the influence of voxel resolution on petrophysical properties. We then introduce a numerical coarsening scheme which is used to coarsen a high voxel resolution image (4.4 μm) to lower resolutions (6.2 μm, 8.3 μm and 10.2 μm) and study the impact of coarsening data on macroscopic and multi-phase properties. Numerical coarsening of high resolution data is found to be superior to using a lower resolution scan because it

  12. A voxelization approach to navigate through nested geometries

    CERN Document Server

    Harrison, Brent Andrew

    2016-01-01

    High energy physics experiment software typically implements a detailed description of the geometry of the relevant detector. As modern detectors increase in complexity, modelling them becomes more challenging. Typically such models are built as a nested hierarchy of O(10000) volumes reaching a depth of 10 - 20. It is desirable to develop data structures and algorithms which allow fast and efficient navigation though a given detector geometry model. We investigate the feasibility of voxelisation techniques to this end.

  13. Hemodynamics in Korean Hemorrhagic Fever

    International Nuclear Information System (INIS)

    Han, Ji Young; Lee, Jung Sang; Koh, Chang Soon; Lee, Mun Ho

    1974-01-01

    The author in an attempt to evaluate hemodynamic changes in the clinical stages of Korean hemorrhagic fever measured plasma volume, cardiac output and effective renal plasma flow utilizing radioisoto as during various phases of the disease. Cardiac output was measured by radiocardiography with external monitoring method using RIHSA. Effective renal plasma flow was obtained from blood clearance curve drawn by external monitoring after radiohippuran injection according to the method described by Razzak et al. The study was carried out in thirty-eight cases of Korean hemorrhagic fever and the following conclusions were obtained. 1) Plasma volume was increased in the patients during the oliguric and hypertensive-diuretic phases, while it was normal in the patients during the normotensive-diuretic phase. 2) Cardiac index was increased in the patients during the oliguric phase and was slightly increased in the patients at the hypertensive diuretic phase. It was normal in the other phases. 3) Total peripheral resistance was increased in the hypertensive patients during diuretic phase, while it was normal in the rest of phases. 4) Effective renal plasma flow was significantly reduced in the patients during the oliguric and diuretic phases as well as at one month after the oliguric onset. There was no significant difference between the oliguric and the early diuretic phases. Renal plasma flow in the group of patients at one month after the oliguric onset was about 45% of the normal, however, it returned to normal level at six months after the onset. 5) Clinical syndrome of relative hypervolemia was observed in some patients during the oliguric phase or hypertensive diuretic phase. Characteristic hemodynamic findings were high cardiac output and normal to relatively increased peripheral resistance these cases. Relatively increased circulating blood volumes due to decreased effective vascular space was suggested for the mechanism of relative hypervolemia. 6) Cardiac

  14. Marital satisfaction and maternal depressive symptoms among Korean mothers transitioning to parenthood.

    Science.gov (United States)

    Choi, Eunsil

    2016-06-01

    Although many empirical findings support associations between marital satisfaction and depressive symptoms, gaps remain in our understanding of the magnitude and direction of the associations between marital satisfaction and depressive symptoms as well as the associations in a collectivistic culture. The present study examined autoregressive cross-lagged associations between marital satisfaction and maternal depressive symptoms across a 3-year investigation in a sample of Korean mothers transitioning to parenthood. The sample consisted of 2,078 mothers in the Panel Study of Korean Children. The mothers reported marital satisfaction and maternal depressive symptoms annually for 3 years. The results of an autoregressive cross-lagged model revealed bidirectional associations between marital satisfaction and maternal depressive symptoms. The findings provide evidence of an interactional model of depression in a sample of Korean mothers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. "I'm Never Going to Be Part of It": Identity, Investment and Learning Korean

    Science.gov (United States)

    Gearing, Nigel; Roger, Peter

    2018-01-01

    This study investigated the willingness of 14 English-speaking EFL instructors living and working in South Korea to invest in practices connected with learning and using the Korean language. A model of investment for the "new world order" (Darvin, R., and B. Norton. 2015. "Identity and a Model of Investment in Applied…

  16. Agent Orange exposure and risk of death in Korean Vietnam veterans: Korean Veterans Health Study.

    Science.gov (United States)

    Yi, Sang-Wook; Ryu, So-Yeon; Ohrr, Heechoul; Hong, Jae-Seok

    2014-12-01

    Agent Orange (AO) was a mixture of phenoxy herbicides, containing several dioxin impurities including 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Various military herbicides, including AO, were sprayed by the US military and allied forces for military purposes during the Vietnam War. This study was performed to identify the associations between the AO exposure and mortality in Korean Vietnam veterans. From 1 January 1992 to 31 December 2005, 180 639 Korean Vietnam veterans were followed up for vital status and cause of death. The AO exposure index was based on the proximity of the veteran's unit to AO-sprayed areas, using a geographical information system-based model. The adjusted hazard ratios and 95% confidence intervals were calculated by Cox's proportional hazard model. The mortality from all causes of death was elevated with AO exposure. The deaths due to all sites of cancers combined and some specific cancers, including cancers of the stomach, small intestine, liver, larynx, lung, bladder and thyroid gland, as well as chronic myeloid leukaemia, were positively associated with AO exposure. The deaths from angina pectoris, chronic obstructive pulmonary disease and liver disease including liver cirrhosis were also increased with an increasing AO exposure. Overall, this study suggests that AO/TCDD exposure may account for mortality from various diseases even several decades after exposure. Further research is needed to better understand the long-term effects of AO/TCDD exposure on human health. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  17. Volumetric visualization of multiple-return LIDAR data: Using voxels

    Science.gov (United States)

    Stoker, Jason M.

    2009-01-01

    Elevation data are an important component in the visualization and analysis of geographic information. The creation and display of 3D models representing bare earth, vegetation, and surface structures have become a major focus of light detection and ranging (lidar) remote sensing research in the past few years. Lidar is an active sensor that records the distance, or range, of a laser usually fi red from an airplane, helicopter, or satellite. By converting the millions of 3D lidar returns from a system into bare ground, vegetation, or structural elevation information, extremely accurate, high-resolution elevation models can be derived and produced to visualize and quantify scenes in three dimensions. These data can be used to produce high-resolution bare-earth digital elevation models; quantitative estimates of vegetative features such as canopy height, canopy closure, and biomass; and models of urban areas such as building footprints and 3D city models.

  18. Prevalence and Risk Factors of Adolescents Smoking: Difference Between Korean and Korean-Chinese

    Directory of Open Access Journals (Sweden)

    SoonBok E. Park, RN, PhD

    2011-09-01

    Conclusion: These results highlight the differences of smoking prevalence and risk factors between Korean-Chinese students and Korean students. The findings may help health educators and researchers to better understand adolescent smoking and risk factors cross culturally and aid in the development of more effective education programs, which could lead to preventing tobacco use among these populations.

  19. Historic Factors Influencing Korean Higher Education. Korean Studies Series, No. 17.

    Science.gov (United States)

    Jeong-kyu, Lee

    This book examines the religious and philosophical factors historically affecting Korean higher education, and the characteristics of contemporary Korean higher education in relation to organizational structure, leadership, and organizational culture. The book is organized into 4 parts, with 11 chapters. Part One focuses on identifying the problem…

  20. Korean Version of Inventory of Complicated Grief Scale: Psychometric Properties in Korean Adolescents.

    Science.gov (United States)

    Han, Doug Hyun; Lee, Jung Jae; Moon, Duk-Soo; Cha, Myoung-Jin; Kim, Min A; Min, Seonyeong; Yang, Ji Hoon; Lee, Eun Jeong; Yoo, Seo Koo; Chung, Un-Sun

    2016-01-01

    We aimed to validate the Inventory of Complicated Grief (ICG)-Korean version among 1,138 Korean adolescents, representing a response rate of 57% of 1,997 students. Participants completed a set of questionnaires including demographic variables (age, sex, years of education, experience of grief), the ICG, the Children's Depression Inventory (CDI) and the Lifetime Incidence of Traumatic Events-Child (LITE-C). Exploratory factor analysis was performed to determine whether the ICG items indicated complicated grief in Korean adolescents. The internal consistency of the ICG-Korean version was Cronbach's α=0.87. The test-retest reliability for a randomly selected sample of 314 participants in 2 weeks was r=0.75 (PKaiser-Meyer-Olkin Measure of Sampling Adequacy=0.911; Bartlett's Test of Sphericity, χ(2)=13,144.7, P<0.001). After omission of 3 items, the value of Cronbach's α increased from 0.87 for the 19-item ICG-Korean version to 0.93 for the 16-item ICG-Korean version. These results suggest that the ICG is a useful tool in assessing for complicated grief in Korean adolescents. However, the 16-item version of the ICG appeared to be more valid compared to the 19-item version of the ICG. We suggest that the 16-item version of the ICG be used to screen for complicated grief in Korean adolescents.

  1. Acculturative Stress and Coping: Gender Differences among Korean and Korean American University Students

    Science.gov (United States)

    Lee, Diane Sookyoung; Padilla, Amado M.

    2014-01-01

    In this study we examined acculturative stress and coping among 86 students of Korean heritage at an American university. Participants indicated their stress levels on 3 scales of cultural adaptation: discrimination, language and cultural ties, and social distance. Findings show that self-identified Korean students displayed higher levels of…

  2. Dose estimation of patients in CT examinations using EGS4 Monte-Carlo simulation of voxel phantom

    International Nuclear Information System (INIS)

    Akahane, K.; Kai, M.; Kusama, T.; Saito, K.

    2002-01-01

    A voxel phantom based on CT images of one Japanese male have developed in Japan Atomic Energy Research Institute. Dose calculations of patients in X-ray CT examinations were performed using the voxel phantom and EGS4 Monte-Carlo simulation code. The organ doses of the patients were estimated

  3. Dose estimation of patients in CT examinations using EGS4 Monte-Carlo simulation of voxel phantom

    Energy Technology Data Exchange (ETDEWEB)

    Akahane, K.; Kai, M.; Kusama, T. [Oita Univ., of Nursing and Health Sciences, Oita-Ken (Japan); Saito, K. [JAERI, Ibaraki-ken (Japan)

    2002-07-01

    A voxel phantom based on CT images of one Japanese male have developed in Japan Atomic Energy Research Institute. Dose calculations of patients in X-ray CT examinations were performed using the voxel phantom and EGS4 Monte-Carlo simulation code. The organ doses of the patients were estimated.

  4. The Relevance Voxel Machine (RVoxM): A Bayesian Method for Image-Based Prediction

    DEFF Research Database (Denmark)

    Sabuncu, Mert R.; Van Leemput, Koen

    2011-01-01

    This paper presents the Relevance VoxelMachine (RVoxM), a Bayesian multivariate pattern analysis (MVPA) algorithm that is specifically designed for making predictions based on image data. In contrast to generic MVPA algorithms that have often been used for this purpose, the method is designed to ...

  5. Application of Electron Dose Kernels to account for heterogeneities in voxelized phantoms

    International Nuclear Information System (INIS)

    Al-Basheer, A. K.; Sjoden, G. E.; Ghita, M.; Bolch, W.

    2009-01-01

    In this paper, we present work on the application of the Electron Dose Kernel discrete ordinates method (EDK-S N ) to compute doses and account for material heterogeneities using high energy external photon beam irradiations in voxelized human phantoms. EDKs are pre-computed using photon pencil 'beamlets' that lead to dose delivery in tissue using highly converged Monte Carlo. Coupling the EDKs to accumulate dose scaled by integral photon fluences computed using S N methods in dose driving voxels (DDVs) allows for the full charged particle physics computed dose to be accumulated throughout the voxelized phantom, and is the basis of the EDK-S N method, which is fully parallelized. For material heterogeneities, a density scaling correction factor is required to yield good agreement. In a fully voxelized phantom, all doses were in agreement with those determined by independent Monte Carlo computations. We are continuing to expand upon the development of this robust approach for rapid and accurate determination of whole body and out of field organ doses due to high energy x-ray beams. (authors)

  6. Multimodal Voxel-Based Meta-Analysis of White Matter Abnormalities in Obsessive-Compulsive Disorder

    NARCIS (Netherlands)

    Radua, J.; Grau, M.; van den Heuvel, O.A.; Thiebaut de Schotten, M.; Stein, D.J.; Canales-Rodriguez, E.J.; Catani, M.; Mataix-Cols, D.

    2014-01-01

    White matter (WM) abnormalities have long been suspected in obsessive-compulsive disorder (OCD) but the available evidence has been inconsistent. We conducted the first multimodal meta-analysis of WM volume (WMV) and fractional anisotropy (FA) studies in OCD. All voxel-wise studies comparing WMV or

  7. A software for digital image processing used in constructions of voxels phantoms

    International Nuclear Information System (INIS)

    Vieira, Jose Wilson; Fernando Roberto de Andrade

    2008-01-01

    This paper presents, based on menus and menu items, the second version of software DIP-Digital Image Processing, that reads, edits and writes binary files containing the matrix 3D corresponding to a transversal voxels images of a certain geometry that may be a human body or other volume of interest

  8. Dose conversion coefficients calculated using a series of adult Japanese voxel phantoms against external photon exposure

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2008-10-01

    This report presents a complete set of conversion coefficients of organ doses and effective doses calculated for external photon exposure using five Japanese adult voxel phantoms developed at the Japan Atomic Energy Agency (JAEA). At the JAEA, high-resolution Japanese voxel phantoms have been developed to clarify the variation of organ doses due to the anatomical characteristics of Japanese, and three male phantoms (JM, JM2 and Otoko) and two female phantoms (JF and Onago) have been constructed up to now. The conversion coefficients of organ doses and effective doses for the five voxel phantoms have been calculated for six kinds of idealized irradiation geometries from monoenergetic photons ranging from 0.01 to 10 MeV using EGS4, a Monte Carlo code for the simulation of coupled electron-photon transport. The dose conversion coefficients are given as absorbed dose and effective dose per unit air-kerma free-in-air, and are presented in tables and figures. The calculated dose conversion coefficients are compared with those of voxel phantoms based on the Caucasian and the recommended values in ICRP74 in order to discuss (1) variation of organ dose due to the body size and individual anatomy, such as position and shape of organs, and (2) effect of posture on organ doses. The present report provides valuable data to study the influence of the body characteristics of Japanese upon the organ doses and to discuss developing reference Japanese and Asian phantoms. (author)

  9. Automated voxel-based analysis of brain perfusion SPECT for vasospasm after subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Iwabuchi, S.; Yokouchi, T.; Hayashi, M.; Kimura, H.; Tomiyama, A.; Hirata, Y.; Saito, N.; Harashina, J.; Nakayama, H.; Sato, K.; Aoki, K.; Samejima, H.; Ueda, M.; Terada, H.; Hamazaki, K.

    2008-01-01

    We evaluated regional cerebral blood flow (rCBF) during vasospasm after subarachnoid haemorrhage ISAH) using automated voxel-based analysis of brain perfusion single-photon emission computed tomography (SPELT). Brain perfusion SPECT was performed 7 to 10 days after onset of SAH. Automated voxel-based analysis of SPECT used a Z-score map that was calculated by comparing the patients data with a control database. In cases where computed tomography (CT) scans detected an ischemic region due to vasospasm, automated voxel-based analysis of brain perfusion SPECT revealed dramatically reduced rCBF (Z-score ≤ -4). No patients with mildly or moderately diminished rCBF (Z-score > -3) progressed to cerebral infarction. Some patients with a Z-score < -4 did not progress to cerebral infarction after active treatment with a angioplasty. Three-dimensional images provided detailed anatomical information and helped us to distinguish surgical sequelae from vasospasm. In conclusion, automated voxel-based analysis of brain perfusion SPECT using a Z-score map is helpful in evaluating decreased rCBF due to vasospasm. (author)

  10. Anatomical specificity of vascular endothelial growth factor expression in glioblastomas: a voxel-based mapping analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Xing [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Wang, Yinyan [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Capital Medical University, Department of Neuropathology, Beijing Neurosurgical Institute, Beijing (China); Wang, Kai; Ma, Jun; Li, Shaowu [Capital Medical University, Department of Neuroradiology, Beijing Tiantan Hospital, Beijing (China); Liu, Shuai [Chinese Academy of Medical Sciences and Peking Union Medical College, Departments of Neurosurgery, Peking Union Medical College Hospital, Beijing (China); Liu, Yong [Chinese Academy of Sciences, Brainnetome Center, Institute of Automation, Beijing (China); Jiang, Tao [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Beijing Academy of Critical Illness in Brain, Department of Clinical Oncology, Beijing (China)

    2016-01-15

    The expression of vascular endothelial growth factor (VEGF) is a common genetic alteration in malignant gliomas and contributes to the angiogenesis of tumors. This study aimed to investigate the anatomical specificity of VEGF expression levels in glioblastomas using voxel-based neuroimaging analysis. Clinical information, MR scans, and immunohistochemistry stains of 209 patients with glioblastomas were reviewed. All tumor lesions were segmented manually and subsequently registered to standard brain space. Voxel-based regression analysis was performed to correlate the brain regions of tumor involvement with the level of VEGF expression. Brain regions identified as significantly associated with high or low VEGF expression were preserved following permutation correction. High VEGF expression was detected in 123 (58.9 %) of the 209 patients. Voxel-based statistical analysis demonstrated that high VEGF expression was more likely in tumors located in the left frontal lobe and the right caudate and low VEGF expression was more likely in tumors that occurred in the posterior region of the right lateral ventricle. Voxel-based neuroimaging analysis revealed the anatomic specificity of VEGF expression in glioblastoma, which may further our understanding of genetic heterogeneity during tumor origination. This finding provides primary theoretical support for potential future application of customized antiangiogenic therapy. (orig.)

  11. Anatomical specificity of vascular endothelial growth factor expression in glioblastomas: a voxel-based mapping analysis

    International Nuclear Information System (INIS)

    Fan, Xing; Wang, Yinyan; Wang, Kai; Ma, Jun; Li, Shaowu; Liu, Shuai; Liu, Yong; Jiang, Tao

    2016-01-01

    The expression of vascular endothelial growth factor (VEGF) is a common genetic alteration in malignant gliomas and contributes to the angiogenesis of tumors. This study aimed to investigate the anatomical specificity of VEGF expression levels in glioblastomas using voxel-based neuroimaging analysis. Clinical information, MR scans, and immunohistochemistry stains of 209 patients with glioblastomas were reviewed. All tumor lesions were segmented manually and subsequently registered to standard brain space. Voxel-based regression analysis was performed to correlate the brain regions of tumor involvement with the level of VEGF expression. Brain regions identified as significantly associated with high or low VEGF expression were preserved following permutation correction. High VEGF expression was detected in 123 (58.9 %) of the 209 patients. Voxel-based statistical analysis demonstrated that high VEGF expression was more likely in tumors located in the left frontal lobe and the right caudate and low VEGF expression was more likely in tumors that occurred in the posterior region of the right lateral ventricle. Voxel-based neuroimaging analysis revealed the anatomic specificity of VEGF expression in glioblastoma, which may further our understanding of genetic heterogeneity during tumor origination. This finding provides primary theoretical support for potential future application of customized antiangiogenic therapy. (orig.)

  12. Calculation of conversion coefficients for effective dose by using voxel phantoms with defined genus for radiodiagnostic common examinations

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Vieira, J.W.; Loureiro, E.C.M.; Hoff, G.

    2004-01-01

    Patient exposure from radiological examinations is usually quantified in terms of average absorbed dose or equivalent dose to certain radiosensitive organs of the human body. As these quantities cannot be measured in vivo, it is common practice to use physical or computational exposure models, which simulate the exposure to the patient in order to determine not only the quantities of interest (absorbed or equivalent dose), but also at the same time measurable quantities for the exposure conditions given. The ratio between a quantity of interest and a measurable quantity is called a conversion coefficient (CC), which is a function of the source and field parameters (tube voltage, filtration, field size, field position, focus-to-skin distance, etc.), the anatomical properties of the phantom, the elemental composition of relevant body tissues, and the radiation transport method applied. As the effective dose represents a sum over 23 risk-weighted organ and tissue equivalent doses, its determination practically implies the measurement or calculation of a complete distribution of equivalent doses throughout the human body. This task can be resolved most efficiently by means of computational exposure models, which consist of a virtual representation of the human body, also called phantom, connected to a Monte Carlo radiation transport computer code. The recently introduced MAX (Male Adult voXel) and FAXht (Female Adult voXel) head+trunk phantoms have been chosen for this task. With respect to their anatomical properties these phantoms correspond fairly well to the data recommended by the ICRP for the Reference Adult Male and Female. (author)

  13. A Voxel-Based Morphometric MRI Study in Young Adults with Borderline Personality Disorder.

    Directory of Open Access Journals (Sweden)

    Xinhu Jin

    Full Text Available Increasing evidence has documented subtle changes in brain morphology and function in patients with borderline personality disorder (BPD. However, results of magnetic resonance imaging volumetry in patients with BPD are inconsistent. In addition, few researchers using voxel-based morphometry (VBM have focused on attachment and childhood trauma in BPD. This preliminary study was performed to investigate structural brain changes and their relationships to attachment and childhood trauma in a homogenous sample of young adults with BPD.We examined 34 young adults with BPD and 34 healthy controls (HCs to assess regionally specific differences in gray matter volume (GMV and gray matter concentration (GMC. Multiple regressions between brain volumes measured by VBM and attachment style questionnaire (ASQ and childhood trauma questionnaire (CTQ scores were performed.Compared with HCs, subjects with BPD showed significant bilateral increases in GMV in the middle cingulate cortex (MCC/posterior cingulate cortex (PCC/precuneus. GMC did not differ significantly between groups. In multiple regression models, ASQ insecure attachment scores were correlated negatively with GMV in the precuneus/MCC and middle occipital gyrus in HCs, HCs with more severe insecure attachment showed smaller volumes in precuneus/MCC and middle occipital gyrus, whereas no negative correlations between insecure attachment and GMV in any region were found in BPD group. In addition, CTQ total scores were not correlated with GMV in any region in the two groups respectively.Our findings fit with those of previous reports of larger precuneus GMV in patients with BPD, and suggest that GMV in the precuneus/MCC and middle occipital gyrus is associated inversely with insecure attachment style in HCs. Our finding of increased GMV in the MCC and PCC in patients with BPD compared with HCs has not been reported in previous VBM studies.

  14. Korean Clinic Based Outcome Measure Studies

    Directory of Open Access Journals (Sweden)

    Jongbae Park

    2003-02-01

    Full Text Available Background: Evidence based medicine has become main tools for medical practice. However, conducting a highly ranked in the evidence hierarchy pyramid is not easy or feasible at all times and places. There remains a room for descriptive clinical outcome measure studies with admitting the limit of the intepretation. Aims: Presents three Korean clinic based outcome measure studies with a view to encouraging Korean clinicians to conduct similar studies. Methods: Three studies are presented briefly here including 1 Quality of Life of liver cancer patients after 8 Constitutional acupuncture; 2 Developing a Korean version of Measuring yourself Medical Outcome profile (MYMOP; and 3 Survey on 5 Shu points: a pilot In the first study, we have included 4 pr