WorldWideScience

Sample records for kontaktltsede air optix

  1. Optix: A Monte Carlo scintillation light transport code

    Energy Technology Data Exchange (ETDEWEB)

    Safari, M.J., E-mail: mjsafari@aut.ac.ir [Department of Energy Engineering and Physics, Amir Kabir University of Technology, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Afarideh, H. [Department of Energy Engineering and Physics, Amir Kabir University of Technology, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Ghal-Eh, N. [School of Physics, Damghan University, PO Box 36716-41167, Damghan (Iran, Islamic Republic of); Davani, F. Abbasi [Nuclear Engineering Department, Shahid Beheshti University, PO Box 1983963113, Tehran (Iran, Islamic Republic of)

    2014-02-11

    The paper reports on the capabilities of Monte Carlo scintillation light transport code Optix, which is an extended version of previously introduced code Optics. Optix provides the user a variety of both numerical and graphical outputs with a very simple and user-friendly input structure. A benchmarking strategy has been adopted based on the comparison with experimental results, semi-analytical solutions, and other Monte Carlo simulation codes to verify various aspects of the developed code. Besides, some extensive comparisons have been made against the tracking abilities of general-purpose MCNPX and FLUKA codes. The presented benchmark results for the Optix code exhibit promising agreements. -- Highlights: • Monte Carlo simulation of scintillation light transport in 3D geometry. • Evaluation of angular distribution of detected photons. • Benchmark studies to check the accuracy of Monte Carlo simulations.

  2. Performance of Lotrafilcon B silicone hydrogel contact lenses in experienced low-Dk/t daily lens wearers.

    Science.gov (United States)

    Dillehay, Sally M; Miller, Marian B

    2007-11-01

    The silicone hydrogel lens O2OPTIX with a Dk/t of 138 (at -3.00 diopters [D]) was evaluated and compared with patients' habitual low-Dk/t lenses. This large, multisite (United States and Canada), single-masked study enrolled experienced daily-wear, low-Dk/t, 2-week replacement soft contact lens wearers. Subjects underwent baseline evaluations and were fitted with O2OPTIX lenses for a 2-week period. After 2 weeks, subjects returned for assessment versus their habitual lenses. Data for 760 subjects were analyzed. The overall average habitual contact lens power was -3.13 D, and the average O2OPTIX lens power was -3.22 D. Biomicroscopy evaluations showed improvements in signs related to corneal health with O2OPTIX. Conjunctival and limbal redness, corneal neovascularization, corneal edema, and corneal and conjunctival staining all decreased significantly from baseline. O2OPTIX lenses performed better than habitual lenses in terms of comfort, symptoms, and overall preference. When wearing O2OPTIX lenses, significantly fewer subjects reported problems compared to their habitual lenses, including uncomfortable lens wear (-20.3%), redness (-44.5%), dryness during the day (-40.2%), and dryness at the end of the day (-34.4%); 47.9% reported that they could wear O2OPTIX lenses longer than their habitual lenses. At the end of study, among those with a preference, a significantly greater proportion of patients (60.3%) preferred O2OPTIX lenses to their habitual lenses. Daily wear of O2OPTIX lenses resulted in improvements in corneal signs of health and patient symptoms and provided excellent vision and comfort. O2OPTIX lenses were preferred by subjects over their habitual lenses.

  3. Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.

    Science.gov (United States)

    Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Ho, Arthur

    2015-01-01

    To compare the contributions of single vision (SVCL) and multifocal contact lenses (MFCL) to the relative peripheral refraction (RPR) profiles obtained via an autorefractor and an aberrometer in a pilot study. Two instruments, Shin-Nippon NVision K5001 (SN) and COAS-HD, were modified to permit open field PR measurements. Two myopic adults (CF, RB) were refracted (cycloplegia) under eight conditions: baseline (no CL); three SVCLs: Focus Dailies(®) (Alcon, USA), PureVision(®) (Bausch & Lomb, USA) and AirOptix(®) (Alcon, USA); and four MFCLs: AirOptix(®) (Alcon, USA), Proclear(®) Distant and Near (Cooper Vision, USA), and PureVision(®) (Bausch & Lomb, USA). CLs had a distance prescription of -2.00D and for MFCLs, a +2.50D Add was selected. Five independent measurements were performed at field angles from -40° to +40° in 10° increments with both instruments. The COAS-HD measures were analyzed at 3mm pupil diameter. Results are reported as a change in the relative PR profile, as refractive power vector components: M, J180, and J45. Overall, at baseline, M, J180 and J45 measures obtained with SN and COAS-HD were considerably different only for field angles ≥±30°, which agreed well with previous studies. With respect to M, this observation held true for most SVCLs with a few exceptions. The J180 measures obtained with COAS-HD were considerably greater in magnitude than those acquired with SN. For SVCLs, the greatest difference was found at -40° for AirOptix SV (ΔCF=3.20D, ΔRB=1.56D) and for MFCLs it was for Proclear Distance at -40° (ΔCF=2.58D, ΔRB=1.39D). The J45 measures obtained with SN were noticeably different to the respective measures with COAS-HD, both in magnitude and sign. The greatest difference was found with AirOptix Multifocal in subject RB at -40°, where the COAS-HD measurement was 1.50D more positive. In some cases, the difference in the RPR profiles observed between subjects appeared to be associated with CL decentration. For most test

  4. A comparison of regimen methods for the removal and inactivation of bacteria, fungi and Acanthamoeba from two types of silicone hydrogel lenses.

    Science.gov (United States)

    Kilvington, Simon; Lonnen, James

    2009-04-01

    To compare the antimicrobial efficacy of commercial contact lens solutions when used according to the manufacturers' recommended regimens with two types of silicone hydrogel lenses. Four multipurpose contact lens care solutions were examined, representing manufacturer recommended regimens of "rub & rinse", "no rub, rinse" or "no rub, no rinse". Test organisms were Pseudomonas aeruginosa, Serratia marcescens, Staphylococcus aureus, Fusarium solani, Candida albicans and Acanthamoeba castellanii (trophozoites and cysts). Organisms, in the presence of organic soil, were inoculated on to Acuvue Oasys or Air Optix lenses and subjected to the solution manufacturer's recommended regimen. The number of surviving organisms on the lenses and in the soak solution was enumerated in accordance with ISO 14729. ISO 14729 dictates that for a given organism the combined average number of surviving microbes from the lenses and disinfectant soaking solution must be bacteria, fungi and Acanthamoeba with both lens types. Solutions employing "no rub, rinse" were less satisfactory but significantly better than "no rub, no rinse". Significant differences were found in organism survival on the lenses with greater numbers remaining on the Air Optix compared to Oasys (plenses. Accordingly, it would seem prudent to recommend that contact lens care systems include a rub step as part of the hygiene regimen.

  5. Opticks : GPU Optical Photon Simulation for Particle Physics using NVIDIA® OptiX™

    Science.gov (United States)

    C, Blyth Simon

    2017-10-01

    Opticks is an open source project that integrates the NVIDIA OptiX GPU ray tracing engine with Geant4 toolkit based simulations. Massive parallelism brings drastic performance improvements with optical photon simulation speedup expected to exceed 1000 times Geant4 when using workstation GPUs. Optical photon simulation time becomes effectively zero compared to the rest of the simulation. Optical photons from scintillation and Cherenkov processes are allocated, generated and propagated entirely on the GPU, minimizing transfer overheads and allowing CPU memory usage to be restricted to optical photons that hit photomultiplier tubes or other photon detectors. Collecting hits into standard Geant4 hit collections then allows the rest of the simulation chain to proceed unmodified. Optical physics processes of scattering, absorption, scintillator reemission and boundary processes are implemented in CUDA OptiX programs based on the Geant4 implementations. Wavelength dependent material and surface properties as well as inverse cumulative distribution functions for reemission are interleaved into GPU textures providing fast interpolated property lookup or wavelength generation. Geometry is provided to OptiX in the form of CUDA programs that return bounding boxes for each primitive and ray geometry intersection positions. Some critical parts of the geometry such as photomultiplier tubes have been implemented analytically with the remainder being tessellated. OptiX handles the creation and application of a choice of acceleration structures such as boundary volume hierarchies and the transparent use of multiple GPUs. OptiX supports interoperation with OpenGL and CUDA Thrust that has enabled unprecedented visualisations of photon propagations to be developed using OpenGL geometry shaders to provide interactive time scrubbing and CUDA Thrust photon indexing to enable interactive history selection.

  6. Assessment of enamel demineralization using conventional, digital, and digitized radiography Avaliação da desmineralização do esmalte por meio de radiografias convencional, digital e digitalizada

    Directory of Open Access Journals (Sweden)

    Rívea Inês Ferreira

    2006-04-01

    Full Text Available This experimental research aimed at evaluating the accuracy of enamel demineralization detection using conventional, digital, and digitized radiographs, as well as to compare radiographs and logarithmically contrast-enhanced subtraction images. Enamel subsurface demineralization was induced on one of the approximal surfaces of 49 sound third molars. Standardized radiographs of the teeth were taken prior to and after the demineralization phase with three digital systems - CygnusRay MPS®, DenOptix® and DIGORA® - and InSight® film. Three radiologists interpreted the pairs of conventional, digital, and digitized radiographs in two different occasions. Logarithmically contrast-enhanced subtraction images were examined by a fourth radiologist only once. Radiographic diagnosis was validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Accuracy was estimated by Receiver Operating Characteristic (ROC analysis. Chi-square test, at a significance level of 5%, was used to compare the areas under the ROC curves (Az calculated for the different imaging modalities. Concerning the radiographs, the DenOptix® system (Az = 0.91 and conventional radiographs (Az = 0.90 presented the highest accuracy values compared with the other three radiographic modalities. However, logarithmically contrast-enhanced subtraction images (Az = 0.98 were significantly more accurate than conventional, digital, and digitized radiographs (p = 0.0000. It can be concluded that the DenOptix® system and conventional radiographs provide better performance for diagnosing enamel subsurface demineralization. Logarithmic subtraction significantly improves radiographic detection.O objetivo desta pesquisa experimental foi investigar a acurácia da detecção de desmineralizações em esmalte por meio de radiografias convencionais, digitais e digitalizadas, e compará-las às imagens por subtração logarítmica. Foram induzidas desmineraliza

  7. 78 FR 34664 - Prospective Grant of Start-up Exclusive Evaluation License: Portable Device and Method for...

    Science.gov (United States)

    2013-06-10

    ...-up Exclusive Evaluation License: Portable Device and Method for Detecting Hematomas AGENCY: National... hematomas. Upon the expiration or termination of the start-up exclusive evaluation license, ArcheOptix will... device and method for detecting hematomas based on near infrared light emitted perpendicularly into a...

  8. Gene Expression Data from the Moon Jelly, Aurelia, Provide Insights into the Evolution of the Combinatorial Code Controlling Animal Sense Organ Development.

    Directory of Open Access Journals (Sweden)

    Nagayasu Nakanishi

    Full Text Available In Bilateria, Pax6, Six, Eya and Dach families of transcription factors underlie the development and evolution of morphologically and phyletically distinct eyes, including the compound eyes in Drosophila and the camera-type eyes in vertebrates, indicating that bilaterian eyes evolved under the strong influence of ancestral developmental gene regulation. However the conservation in eye developmental genetics deeper in the Eumetazoa, and the origin of the conserved gene regulatory apparatus controlling eye development remain unclear due to limited comparative developmental data from Cnidaria. Here we show in the eye-bearing scyphozoan cnidarian Aurelia that the ectodermal photosensory domain of the developing medusa sensory structure known as the rhopalium expresses sine oculis (so/six1/2 and eyes absent/eya, but not optix/six3/6 or pax (A&B. In addition, the so and eya co-expression domain encompasses the region of active cell proliferation, neurogenesis, and mechanoreceptor development in rhopalia. Consistent with the role of so and eya in rhopalial development, developmental transcriptome data across Aurelia life cycle stages show upregulation of so and eya, but not optix or pax (A&B, during medusa formation. Moreover, pax6 and dach are absent in the Aurelia genome, and thus are not required for eye development in Aurelia. Our data are consistent with so and eya, but not optix, pax or dach, having conserved functions in sensory structure specification across Eumetazoa. The lability of developmental components including Pax genes relative to so-eya is consistent with a model of sense organ development and evolution that involved the lineage specific modification of a combinatorial code that specifies animal sense organs.

  9. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens.

    Science.gov (United States)

    Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam

    2017-12-01

    To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Optimization of Monte Carlo algorithms and ray tracing on GPUs

    International Nuclear Information System (INIS)

    Bergmann, R.M.; Vujic, J.L.

    2013-01-01

    To take advantage of the computational power of GPUs (Graphical Processing Units), algorithms that work well on CPUs must be modified to conform to the GPU execution model. In this study, typical task-parallel Monte Carlo algorithms have been reformulated in a data-parallel way, and the benefits of doing so are examined. We were able to show that the data-parallel approach greatly improves thread coherency and keeps thread blocks busy, improving GPU utilization compared to the task-parallel approach. Data-parallel does not, however, outperform the task-parallel approach in regards to speedup over CPU. Regarding the ray-tracing acceleration, OptiX shows promise for providing enough ray tracing speed to be used in a full 3D Monte Carlo neutron transport code for reactor calculations. It is important to note that it is necessary to operate on large datasets of particle histories in order to have good performance in both OptiX and the data-parallel algorithm since this reduces the impact of latency. Our paper also shows the need to rewrite standard Monte Carlo algorithms in order to take full advantage of these new, powerful processor architectures

  11. Prediction of post-operative necrosis after mastectomy: A pilot study utilizing optical diffusion imaging spectroscopy

    Directory of Open Access Journals (Sweden)

    Xie Xian-Jin

    2009-11-01

    Full Text Available Abstract Introduction Flap necrosis and epidermolysis occurs in 18-30% of all mastectomies. Complications may be prevented by intra-operative detection of ischemia. Currently, no technique enables quantitative valuation of mastectomy skin perfusion. Optical Diffusion Imaging Spectroscopy (ViOptix T.Ox Tissue Oximeter measures the ratio of oxyhemoglobin to deoxyhemoglobin over a 1 × 1 cm area to obtain a non-invasive measurement of perfusion (StO2. Methods This study evaluates the ability of ViOptix T.Ox Tissue Oximeter to predict mastectomy flap necrosis. StO2 measurements were taken at five points before and at completion of dissection in 10 patients. Data collected included: demographics, tumor size, flap length/thickness, co-morbidities, procedure length, and wound complications. Results One patient experienced mastectomy skin flap necrosis. Five patients underwent immediate reconstruction, including the patient with necrosis. Statistically significant factors contributing to necrosis included reduction in medial flap StO2 (p = 0.0189, reduction in inferior flap StO2 (p = 0.003, and flap length (p = 0.009. Conclusion StO2 reductions may be utilized to identify impaired perfusion in mastectomy skin flaps.

  12. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  13. 33 CFR 334.1280 - Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. 334.1280 Section 334.1280 Navigation and Navigable... REGULATIONS § 334.1280 Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. (a...

  14. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  15. AirPEx. Air Pollution Exposure Model

    Energy Technology Data Exchange (ETDEWEB)

    Freijer, J.I.; Bloemen, H.J.Th.; De Loos, S.; Marra, M.; Rombout, P.J.A.; Steentjes, G.M.; Van Veen, M.P.

    1997-12-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The principal grounds for studying the inhalatory exposure of humans to air pollutants are formed by the need for realistic exposure/dose estimates to evaluate the health effects of these pollutants. The AirPEx (Air Pollution Exposure) model, developed to assess the time- and space-dependence of inhalatory exposure of humans to air pollution, has been implemented for use as a Windows 3.1 computer program. The program is suited to estimating various exposure and dose quantities for individuals, as well as for populations and subpopulations. This report describes the fundamentals of the AirPEx model and provides a user manual for the computer program. Several examples included in the report illustrate the possibilities of the AirPEx model in exposure assessment. The model will be used at the National Institute of Public Health and the Environment as a tool in analysing the current exposure of the Dutch population to air pollutants. 57 refs.

  16. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative...... and the humidity of the room air. At a low humidity level of 30% an increased velocity could compensate for the decrease in perceived air quality due to an elevated temperature ranging from 20 °C to 26 °C. In a room with 26 °C, increased air movement was also able to compensate for an increase in humidity from 30...... humidity (30, 40 and 70%) and pollution level (low and high). Most of the experiments were performed with and without facially applied airflow at elevated velocity. The importance of the use of recirculated room air and clean, cool and dry outdoor air was studied. The exposures ranged from 60. min to 235...

  17. A mixed air/air and air/water heat pump system ensures the air-conditioning of a cinema; Un systeme mixte PAC air/air et air/eau climatise un cinema

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-03-01

    This article presents the air conditioning system of a new cinema complex of Boulogne (92, France) which comprises a double-flux air processing plant and two heat pumps. Each heat pump has two independent refrigerating loops: one with a air condenser and the other with a water condenser. This system allows to limit the power of the loop and to reduce the size of the cooling tower and of the vertical ducts. This article describes the technical characteristics of the installation: thermodynamic units, smoke clearing, temperature control, air renewing. (J.S.)

  18. Kajian Analitik Perencanaan Pintu Air Pembangkit Listrik Tenaga Air

    OpenAIRE

    Pradoto, Pradoto

    1993-01-01

    Pada pintu air pembangkit listrik tenaga air umumnya dipasang pengauat-penguat (girder). Tujuannya agar pintu air kuat dalam menahan tekanan air. Tekanan air yang diderita oleh pintu air cukup besar karena dipasang pada kedalaman + 50 meter di bawah permukaan air. Permasalahan yang timbul adalah menentukan posisi atau letak girder pada pintu air.

  19. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  20. Air ejector augmented compressed air energy storage system

    Science.gov (United States)

    Ahrens, F.W.; Kartsounes, G.T.

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  1. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  2. Air Consumption Analysis of Air-Jet Weaving

    Directory of Open Access Journals (Sweden)

    RAJ KUMAR KHIANI

    2016-07-01

    Full Text Available In Textile industry, production is mostly key concern for Industry owner. This always has attracted researchers and machines manufacturers to make new developments in process and machines. Air-jet is one of the leading and successful highest productive weaving machines. However, it is now well established that due to add of charges of compressed air, manufacturing cost of air-jet weaving machine is higher as compared with rapier and projectile weaving machines. This is why countries having energy issues do not prefer air-jet weaving machines comparing projectile weaving machines. In this regard, several researchers and machine manufacturers have continuously been working to improve the efficiency of air-jet weft insertion. However, industry practice is as important as design made by researchers. The aim of this research is to investigate the air consumption of air-jet weaving on industrial scale practice. In this study, five weaving machine of same manufacturer and model were selected. It was observed that despite of manufacturing same quality of fabric, air consumption was varying almost in all weaving machines. Conventionally, mill workers adopt hit and trial practice in weaving industry including airpressure setting which leads to variation of nozzle pressure. Main reason of disparity of air consumption in air-jet weaving machines may be variation of distance from compressor to weaving machines, number of joints, un-necessary valve opening and pipes leakages cause an increase of compressed air consumption.

  3. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  4. AirPEx: Air Pollution Exposure Model

    NARCIS (Netherlands)

    Freijer JI; Bloemen HJTh; Loos S de; Marra M; Rombout PJA; Steentjes GM; Veen MP van; LBO

    1997-01-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The

  5. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  6. Air-cooled, hydrogen-air fuel cell

    Science.gov (United States)

    Shelekhin, Alexander B. (Inventor); Bushnell, Calvin L. (Inventor); Pien, Michael S. (Inventor)

    1999-01-01

    An air-cooled, hydrogen-air solid polymer electrolyte (SPE) fuel cell with a membrane electrode assembly operatively associated with a fluid flow plate having at least one plate cooling channel extending through the plate and at least one air distribution hole extending from a surface of the cathode flow field into the plate cooling channel.

  7. An experimental evaluation on air purification performance of Clean-Air Heat Pump (CAHP) air cleaner

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Sun, Yuexia

    2018-01-01

    was 96.8%, which indicated that the most of gaseous pollutants were not accumulated in the CAHP. The regeneration temperature for the wheel could affect the air purification performance of CAHP. At 70 °C of regeneration temperature, the air-cleaning efficiency reached 96.7%. Up to 70% of the outdoor air......The escalation of energy consumption in buildings and heightened concerns about acceptable indoor air quality stimulate interest in the usage of air cleaner as an adjunct for indoor environmental conditioning. A regenerative desiccant wheel integrated into a ventilation system termed Clean-Air Heat...... Pump (CAHP) can improve the air quality during the process of dehumidification without using additional energy. An experimental study in a field lab was performed to investigate the air cleaning performance of CAHP. Photoacoustic gas analyzer-INNOVA was used to characterize chemical removal of indoor...

  8. AirData

    Data.gov (United States)

    U.S. Environmental Protection Agency — The AirData site provides access to yearly summaries of United States air pollution data, taken from EPA's air pollution databases. AirData has information about...

  9. Can a Clean-Air Heat Pump (CAHP) maintain air purification capability when using polluted air for regeneration?

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei

    2018-01-01

    Clean Air Heat Pump (CAHP) was one type of rotary desiccant cooling system which combined a silica gel rotor with a heat pump to achieve air cleaning, dehumidifying and cooling in buildings. Using exhaust air from the conditioned room for regeneration of the silica gel rotor might have an advantage...... on reducing the regeneration air temperature and further improving the energy performance of the CAHP. However, the exhaust air carried a lot of indoor air pollutants. Whether using exhaust air for the regeneration of the silica gel rotor had an impact on the air cleaning performance of the CAHP...... was experimentally studied. The results showed that using the air contained acetone or toluene for regeneration reduced the pollutants removal capability of CAHP with a reduction of approx. 10% in air cleaning efficiency. The energy performance of the CAHP when using exhaust air for regeneration was also evaluated...

  10. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, it's ...

  11. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  12. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  13. 30 CFR 75.1730 - Compressed air; general; compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air; general; compressed air systems... Compressed air; general; compressed air systems. (a) All pressure vessels shall be constructed, installed... Safety and Health district office. (b) Compressors and compressed-air receivers shall be equipped with...

  14. Metal-air batteries with high energy density: Li-air versus Zn-air

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang-Soo; Sun, Tai Kim; Cao, Ruiguo; Choi, Nam-Soon; Lee, Kyu Tae; Cho, Jaephil [Interdisciplinary School of Green Energy, Ulsan National Institute of Science and Technology (UNIST), Ulsan (Korea, Republic of); Liu, Meilin [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA (United States)

    2011-01-01

    In the past decade, there have been exciting developments in the field of lithium ion batteries as energy storage devices, resulting in the application of lithium ion batteries in areas ranging from small portable electric devices to large power systems such as hybrid electric vehicles. However, the maximum energy density of current lithium ion batteries having topatactic chemistry is not sufficient to meet the demands of new markets in such areas as electric vehicles. Therefore, new electrochemical systems with higher energy densities are being sought, and metal-air batteries with conversion chemistry are considered a promising candidate. More recently, promising electrochemical performance has driven much research interest in Li-air and Zn-air batteries. This review provides an overview of the fundamentals and recent progress in the area of Li-air and Zn-air batteries, with the aim of providing a better understanding of the new electrochemical systems. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Nitrogen fluorescence in air for observing extensive air showers

    CERN Document Server

    Keilhauer, B; Fraga, M; Matthews, J; Sakaki, N; Tameda, Y; Tsunesada, Y; Ulrich, A

    2012-01-01

    Extensive air showers initiate the fluorescence emissions from nitrogen molecules in air. The UV-light is emitted isotropically and can be used for observing the longitudinal development of extensive air showers in the atmosphere over tenth of kilometers. This measurement technique is well-established since it is exploited for many decades by several cosmic ray experiments. However, a fundamental aspect of the air shower analyses is the description of the fluorescence emission in dependence on varying atmospheric conditions. Different fluorescence yields affect directly the energy scaling of air shower reconstruction. In order to explore the various details of the nitrogen fluorescence emission in air, a few experimental groups have been performing dedicated measurements over the last decade. Most of the measurements are now finished. These experimental groups have been discussing their techniques and results in a series of \\emph{Air Fluorescence Workshops} commenced in 2002. At the 8$^{\\rm{th}}$ Air Fluoresc...

  16. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  17. AIRS-only Product on Giovanni for Exploring Up-to-date AIRS Observation and Comparing with AIRS+AMSU Product

    Science.gov (United States)

    Ding, F.; Hearty, T. J., III; Theobald, M.; Vollmer, B.; Wei, J.

    2017-12-01

    The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002 for the global observations of the atmospheric state. Giovanni, a web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important variables, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases, from version 6 AIRS product are available on Giovanni. The AIRS is an instrument suite comprised of a hyperspectral infrared instrument AIRS and two multichannel microwave instruments, the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB). As the HSB ceased operation in very early stage of AIRS mission, the AIRS project operates two parallel retrieval algorithms: one using both IR and MW measurements (AIRS+AMSU) and the other using only IR measurements (AIRS-only) for the most time of the mission. The AIRS+AMSU product is better and the variables on Giovanni are from it. However, the generation of AIRS+AMSU product has been suspended since the AMSU instrument anomaly occurred in late 2016. To continue exploring up-to-date AIRS observations, the same set of variables from the AIRS-only product are added on Giovanni by the GES DSIC. This will also support the comparison of AIRS-only with AIRS+AMSU retrievals. In the presentation, we will demonstrate the visualization of AIRS-only product and the plots/statistics of comparison with AIRS+AMSU product using Giovanni.

  18. A new air quality monitoring and early warning system: Air quality assessment and air pollutant concentration prediction.

    Science.gov (United States)

    Yang, Zhongshan; Wang, Jian

    2017-10-01

    Air pollution in many countries is worsening with industrialization and urbanization, resulting in climate change and affecting people's health, thus, making the work of policymakers more difficult. It is therefore both urgent and necessary to establish amore scientific air quality monitoring and early warning system to evaluate the degree of air pollution objectively, and predict pollutant concentrations accurately. However, the integration of air quality assessment and air pollutant concentration prediction to establish an air quality system is not common. In this paper, we propose a new air quality monitoring and early warning system, including an assessment module and forecasting module. In the air quality assessment module, fuzzy comprehensive evaluation is used to determine the main pollutants and evaluate the degree of air pollution more scientifically. In the air pollutant concentration prediction module, a novel hybridization model combining complementary ensemble empirical mode decomposition, a modified cuckoo search and differential evolution algorithm, and an Elman neural network, is proposed to improve the forecasting accuracy of six main air pollutant concentrations. To verify the effectiveness of this system, pollutant data for two cities in China are used. The result of the fuzzy comprehensive evaluation shows that the major air pollutants in Xi'an and Jinan are PM 10 and PM 2.5 respectively, and that the air quality of Xi'an is better than that of Jinan. The forecasting results indicate that the proposed hybrid model is remarkably superior to all benchmark models on account of its higher prediction accuracy and stability. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

    International Nuclear Information System (INIS)

    Guo, H.; Lee, S.C.; Chan, L.Y.

    2004-01-01

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM 10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ) and sulfur dioxide (SO 2 ). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM 10 , TBC, CO and NO 2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM 10 and TBC. The elevated PM 10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM 10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m 3 , and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m 3 , which was above the HKIAQO standard of 1000 CFU/m 3 . The bacteria levels at other three stalls were all below the HKIAQO standard

  20. Pure Air`s Bailly scrubber: A four-year retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Manavi, G.B.; Vymazal, D.C. [Pure Air, Allentown, PA (United States); Sarkus, T.A. [Dept. of Energy, Pittsburgh, PA (United States)

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project has completed four highly successful years of operation at NIPSCO`s Bailly Station. As part of their program, Pure Air has concluded a six-part study of system performance. This paper summarizes the results of the demonstration program, including AFGD performance on coals ranging from 2.0--2.4% sulfur. The paper highlights novel aspects of the Bailly facility, including pulverized limestone injection, air rotary sparger for oxidation, wastewater evaporation system and the production of PowerChip{reg_sign} gypsum. Operations and maintenance which have led to the facility`s notable 99.47% availability record are also discussed. A project company, Pure Air on the Lake Limited Partnership, owns the AFGD facility. Pure Air was the turn key contractor and Air Products and Chemicals, Inc. is the operator of the AFGD system.

  1. Heat Recovery Ventilation for Housing: Air-to-Air Heat Exchangers.

    Science.gov (United States)

    Corbett, Robert J.; Miller, Barbara

    The air-to-air heat exchanger (a fan powered ventilation device that recovers heat from stale outgoing air) is explained in this six-part publication. Topic areas addressed are: (1) the nature of air-to-air heat exchangers and how they work; (2) choosing and sizing the system; (3) installation, control, and maintenance of the system; (4) heat…

  2. Strength of smoke-free air laws and indoor air quality.

    Science.gov (United States)

    Lee, Kiyoung; Hahn, Ellen J; Robertson, Heather E; Lee, Seongjik; Vogel, Suzann L; Travers, Mark J

    2009-04-01

    Smoke-free air laws have been implemented in many Kentucky communities to protect the public from the harmful effects of secondhand smoke exposure. The impact of different strengths of smoke-free air laws on indoor air quality was assessed. Indoor air quality in hospitality venues was assessed in seven communities before and after comprehensive smoke-free air laws and in two communities only after partial smoke-free air laws. One community was measured three times: before any smoke-free air law, after the initial partial law, and after the law was strengthened to cover all workplaces and public places with few exemptions. Real-time measurements of particulate matters with 2.5 mum aerodynamic diameter or smaller (PM(2.5)) were obtained. When comprehensive smoke-free air laws were implemented, indoor PM(2.5) concentrations decreased significantly from 161 to 20 microg/m3. In one community that implemented a comprehensive smoke-free law after initially passing a partial law, indoor PM(2.5) concentrations were 304 microg/m3 before the law, 338 microg/m3 after the partial law, and 9 microg/m3 after the comprehensive law. The study clearly demonstrated that partial smoke-free air laws do not improve indoor air quality. A significant linear trend indicated that PM(2.5) levels in the establishments decreased with fewer numbers of burning cigarettes. Only comprehensive smoke-free air laws are effective in reducing indoor air pollution from secondhand tobacco smoke.

  3. Air Abrasion

    Science.gov (United States)

    ... Chapters What Is Air Abrasion? What Happens? The Pros and Cons Will I Feel Anything? Is Air ... will perform any procedures that use air-abrasion technology. Ask your dentist if he or she uses ...

  4. The urban air; L'air de la ville

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This paper presents the abstracts of conferences proposed during the meeting on the urban air, organized by the French Meteorological Society in november 2002. These conferences dealt with the air quality monitoring, the public health impacts, the air pollution in function of the meteorological effects, the pollutants, the main factors of the air quality and the models of the meteorology. (A.L.B.)

  5. Released air during vapor and air cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz [VŠB-Technical University of Ostrava, Faculty of Mechanical Engineering, Department of Hydromechanics and Hydraulic Equipment, 17. listopadu 15, 708 33 Ostrava-Poruba (Czech Republic)

    2016-06-30

    Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

  6. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  7. Air pollution and the school air environment

    OpenAIRE

    Fsadni, Peter; Montefort, Stephen

    2015-01-01

    There is growing concern about the association of school indoor air quality (SIAQ) with asthma, rhinitis, and rhinoconjunctivitis. Students and school staff deserve the highest standards of school air quality to ensure a safe and productive environment for our children’s education. Existing studies highlight the presence of several air pollutants present within school classrooms that have a direct association with poor health and poor student performance. Very little data exist ab...

  8. Advances in Understanding Air Pollution and Cardiovascular Diseases: The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air)

    Science.gov (United States)

    Kaufman, Joel D.; Spalt, Elizabeth W.; Curl, Cynthia L.; Hajat, Anjum; Jones, Miranda R.; Kim, Sun-Young; Vedal, Sverre; Szpiro, Adam A.; Gassett, Amanda; Sheppard, Lianne; Daviglus, Martha L.; Adar, Sara D.

    2016-01-01

    The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air) leveraged the platform of the MESA cohort into a prospective longitudinal study of relationships between air pollution and cardiovascular health. MESA Air researchers developed fine-scale, state-of-the-art air pollution exposure models for the MESA Air communities, creating individual exposure estimates for each participant. These models combine cohort-specific exposure monitoring, existing monitoring systems, and an extensive database of geographic and meteorological information. Together with extensive phenotyping in MESA—and adding participants and health measurements to the cohort—MESA Air investigated environmental exposures on a wide range of outcomes. Advances by the MESA Air team included not only a new approach to exposure modeling but also biostatistical advances in addressing exposure measurement error and temporal confounding. The MESA Air study advanced our understanding of the impact of air pollutants on cardiovascular disease and provided a research platform for advances in environmental epidemiology. PMID:27741981

  9. Air Baltic: Estonian Air on nurka surutud / Teele Tammeorg

    Index Scriptorium Estoniae

    Tammeorg, Teele

    2010-01-01

    Air Balticu asepresidendi Janis Vanagsi hinnangul on Estonian Air aastaid jätnud tähelepanuta oma peamised turismiturud ning on praegu halvas seisus. Air Baltic on endiselt huvitatud Estonian Airi ostust. Majandus- ja kommunikatsiooniminister Juhan Partsi seisukoht

  10. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  11. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  12. Analysis of air safety in the European system of air traffic

    Directory of Open Access Journals (Sweden)

    О.Є. Луппо

    2008-04-01

    Full Text Available  Article describes air traffic safety provision requirements in the Air Traffic Management system of Europe. Consideration of air traffic variation which affecting the air traffic management operations have been reviewed.

  13. Advanced Architectures and Relatives of Air Electrodes in Zn–Air Batteries

    Science.gov (United States)

    Pan, Jing; Xu, Yang Yang; Yang, Huan; Dong, Zehua; Liu, Hongfang

    2018-01-01

    Abstract Zn–air batteries are becoming the promising power sources for portable and wearable electronic devices and hybrid/electric vehicles because of their high specific energy density and the low cost for next‐generation green and sustainable energy technologies. An air electrode integrated with an oxygen electrocatalyst is the most important component and inevitably determines the performance and cost of a Zn–air battery. This article presents exciting advances and challenges related to air electrodes and their relatives. After a brief introduction of the Zn–air battery, the architectures and oxygen electrocatalysts of air electrodes and relevant electrolytes are highlighted in primary and rechargeable types with different configurations, respectively. Moreover, the individual components and major issues of flexible Zn–air batteries are also highlighted, along with the strategies to enhance the battery performance. Finally, a perspective for design, preparation, and assembly of air electrodes is proposed for the future innovations of Zn–air batteries with high performance. PMID:29721418

  14. Hazardous Air Pollutants

    Science.gov (United States)

    ... Search Main menu Environmental Topics Air Bed Bugs Chemicals and Toxics Environmental Information by Location Greener Living Health Land, ... regulate toxic air pollutants, also known as air toxics, from categories of industrial facilities in two phases . About Hazardous Air Pollutants ...

  15. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  16. The results of air treatment process modeling at the location of the air curtain in the air suppliers and ventilation shafts

    Directory of Open Access Journals (Sweden)

    Nikolaev Aleksandr

    2017-01-01

    Full Text Available In the existing shaft air heater installations (AHI, that heat the air for air suppliers in cold seasons, a heater channel is used. Some parts of the air from the heater go to the channel, other parts are sucked through a pithead by the general shaft pressure drawdown formed by the main ventilation installation (MVI. When this happens, a mix of two air flows leads to a shaft heat regime violation that can break pressurization of intertubular sealers. The problem of energy saving while airing underground mining enterprises is also very important. The proposed solution of both tasks due to the application of an air curtain is described in the article. In cold seasons the air treatment process should be used and it is offered to place an air curtain in the air suppliers shaft above the place of interface of the calorifer channel to a trunk in order to avoid an infiltration (suction of air through the pithead. It’s recommended to use an air curtain in a ventilation shaft because it reduces external air leaks thereby improving energy efficiency of the MVI work. During the mathematical modeling of ventilation and air preparation process (in SolidWorks Flowsimulation software package it was found out that the use of the air curtain in the air supply shaft can increase the efficiency of the AHI, and reduce the electricity consumption for ventilation in the ventilation shaft.

  17. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  18. KERENTANAN KAWASAN TEPI AIR TERHADAP KENAIKAN PERMUKAAN AIR LAUT Kasus Kawasan Tepi Air Kota Surabaya

    Directory of Open Access Journals (Sweden)

    Iwan Suprijanto

    2003-01-01

    Full Text Available Even though global warming are still debates whether it will or not be happened, the changes on climate will influence activities of human. Regarding global warming issue, one of the impact that is very interesting to be investigated is sea level rise. Sea level rise is predicted has very big impact since, in general, in coastal areas locate a lot of important activities for such city or country. On the context of Indonesian locality, most of big cities such as Jakarta, Surabaya, Semarang, Makasar, etc. are located on the coastal area. Since a lot of important activities located on those cities, in general, sea level rise will influence the development processes of those cities. On the basis of the observation gathering in Surabaya City, the impact of sea level rise will influence not only the development of coastal area but also development of Surabaya City in general. The influence is because the area accommodates activities which are very important in city development both for present and future. The activities are port, industrial estate and location for new housing. Abstract in Bahasa Indonesia : Terlepas dari ketidakpastian mengenai terjadi atau tidaknya pemanasan global, setiap perubahan iklim di bumi akan memberikan dampak terhadap kelangsungan hidup manusia. Salah satu kajian yang saat ini banyak dilakukan berkaitan dengan isu pemanasan global adalah mengenai kenaikan permukaan air laut. Pengkajian mengenai kenaikan permukaan air laut tersebut penting mengingat dampak yang akan ditimbulkannya dan dengan kenyataan secara umum kawasan tepi air memegang peranan penting dalam perkembangan suatu kota ataupun negara. Hal ditandai dengan banyaknya aktivitas yang berlokasi di kawasan tepi air. Kondisi geografis Indonesia dengan duapertiga bagian wilayahnya adalah perairan, menjadikan Indonesia memiliki garis pantai terpanjang di dunia. Hal tersebut menjadikan pula beberapa bagian wilayah di Indonesia merupakan kawasan pesisir atau tepi air

  19. MICROBIOLOGICAL CHARACTERISTICS OF THE AIR BLOWN BY WARM AIR HAND DRYERS

    Directory of Open Access Journals (Sweden)

    Recai OÐUR; Omer Faruk TEKBAS; Osman HANCI; Umut OZCAN

    2005-02-01

    Full Text Available The aim of the study was to determine the microbiological characteristics of air blown from warm air hand dryers, and to compare findings with the microbiological characteristics of indoor air in which the dryer settled. Air samples was taken from different public places (shopping centers, restaurants and hospitals and investigated for total viable counts, coagulase negative Staphylococcus, E. Coli, Staphylococcus aureus and enteric pathogens. There were differences between sampling indoor places for some of the microorganisms, but all of the air samples taken from dryers contained more microorganisms than indoor air, and the differences between hand dryers and indoor air were statistically significant (p<0.05 except for enteric pathogens. As a result it could be said that warm air hand dryers could be microbiological contamination sources in restrooms or the other places that they are used. [TAF Prev Med Bull 2005; 4(1.000: 1-7

  20. Indoor air humidity, air quality, and health - An overview.

    Science.gov (United States)

    Wolkoff, Peder

    2018-04-01

    There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture

  1. Air conditioner

    International Nuclear Information System (INIS)

    Sato, Masaaki

    1993-01-01

    The present invention provides an air conditioner which can prevent an undesirable effects on a human body due to radon daughter nuclides in a closed space. That is, the concentration of the radon daughter nuclides in the air in the closed space is continuously measured. A necessary amount of ventilation air is determined based on the measured concentration to generate control signals. External air is introduced into the closed space by the generated control signals. With such procedures, necessary amount of external air is taken from the atmospheric air which can be regarded to have the radon daughter nuclide concentration substantially at zero, thereby enabling to reduce the concentration of the radon daughter nuclides in the closed space. As a result, undesired effects on the human body due to the radon daughter nuclides staying in the closed space can be prevented. According to simulation, the radon daughter nuclides are rapidly decreased only by ventilation only for three times or so in one hour. Accordingly, ventilation is extremely effective and convenient means as a countermeasure for the radon daughter nuclides. (I.S.)

  2. Ensuring clean air: Developing a clean air strategy for British Columbia

    International Nuclear Information System (INIS)

    1992-04-01

    In 1992, a clean air strategy will be developed to incorporate views of British Columbians on ways to meet goals related to air quality. A discussion paper is presented to provide information to those interested in participation in developing this strategy. The paper gives information on air quality issues important to the province, including local air quality, urban smog, ozone layer depletion, and global climate change. The views and concerns expressed by stakeholders who attended the Clean Air Conference in 1991 are summarized. The process used to develop the clean air strategy is outlined and some outcomes to be anticipated from the strategy are suggested, including policies and priorities for action to ensure clean air. Air pollutants of concern are total reduced sulfur, mainly from pulp mills and gas processing plants; smoke from wood burning; sulfur dioxide from pulp mills and gas plants; hydrogen fluoride from aluminum smelting; ground-level ozone in urban areas; and acid rain. Elements of a clean air strategy include a smoke management policy, management strategies for greenhouse gases and ozone smog, ozone layer protection measures, regional air quality management plans, and long-term planning efforts in energy use, transportation modes, community design, and land use. 12 refs., 14 figs., 2 tabs

  3. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  4. Air Land Sea Bulletin

    Science.gov (United States)

    2014-11-01

    Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based at Royal Air Force Honington, Suffolk (United...heavy as an actual weapon.4 Ideally, this practice imbued a soldier with more energy and stamina during real combat, given the feel of the genuine but...through tactical forces, to individual training. Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based

  5. The effect of air velocity on heat stress at increased air temperature

    DEFF Research Database (Denmark)

    Bjerg, B.; Wang, Xiaoshuai; Zhang, Guoqiang

    Increased air velocity is a frequently used method to reduce heat stress of farm animals housed in warm conditions. The main reason why the method works is that higher air velocity increases the convective heat release from the animals. Convective heat release from the animals is strongly related...... to the temperature difference between the surfaces of animals and the surrounding air, and this temperature difference declines when the air temperature approaches the animal body temperature. Consequently it can it by expected that the effect of air velocity decreases at increased air temperature. The literature...... on farm animals in warm conditions includes several thermal indices which incorporate the effect of air velocities. But, surprisingly none of them predicts a decreased influence of air velocity when the air temperature approaches the animal body temperature. This study reviewed published investigations...

  6. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  7. 14 CFR 399.86 - Payments for non-air transportation services for air cargo.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Payments for non-air transportation... Enforcement § 399.86 Payments for non-air transportation services for air cargo. The Board considers that... air carriers for non-air transportation preparation of air cargo shipments are for services ancillary...

  8. 21 CFR 211.46 - Ventilation, air filtration, air heating and cooling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Ventilation, air filtration, air heating and cooling. 211.46 Section 211.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Buildings and Facilities § 211.46 Ventilation, air filtration, air heating and cooling. (a) Adequate...

  9. Air conditioning systems to clean radioactive air

    International Nuclear Information System (INIS)

    Ganz, G.

    1987-01-01

    The author reports a study by the Institutes fuer Klimatechnik and Umweltschutz Giessen that shows that air conditioning systems not only make the atmosphere more comfortable, they also extract dust particles. This cleaning action is also valid for radioactively contaminated air. (G.T.H./Auth.)

  10. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  11. Air pollution meteorology

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Daoo, V J [Environmental Assessment Div., Bhabha Atomic Research Centre, Mumbai (India)

    2002-06-01

    This report is intended as a training cum reference document for scientists posted at the Environmental Laboratories at the Nuclear Power Station Sites and other sites of the Department of Atomic Energy with installations emitting air pollutants, radioactive or otherwise. Since a manual already exists for the computation of doses from radioactive air pollutants, a general approach is take here i.e. air pollutants in general are considered. The first chapter presents a brief introduction to the need and scope of air pollution dispersion modelling. The second chapter is a very important chapter discussing the aspects of meteorology relevant to air pollution and dispersion modelling. This chapter is important because without this information one really does not understand the phenomena affecting dispersion, the scope and applicability of various models or their limitations under various weather and site conditions. The third chapter discusses the air pollution models in detail. These models are applicable to distances of a few tens of kilometres. The fourth chapter discusses the various aspects of meteorological measurements relevant to air pollution. The chapters are followed by two appendices. Apendix A discusses the reliability of air pollution estimates. Apendix B gives some practical examples relevant to general air pollution. It is hoped that the document will prove very useful to the users. (author)

  12. Thermal conditions and perceived air quality in an air-conditioned auditorium

    Science.gov (United States)

    Polednik, Bernard; Guz, Łukasz; Skwarczyński, Mariusz; Dudzińska, Marzenna R.

    2016-07-01

    The study reports measurements of indoor air temperature (T) and relative humidity (RH), perceived air quality (PAQ) and CO2, fine aerosol particle number (PN) and mass (PM1) concentrations in an air conditioned auditorium. The measurements of these air physical parameters have been carried out in the unoccupied auditorium with the air conditioning system switched off (AC off mode) and in the unoccupied and occupied auditorium with the air conditioning system switched off during the night and switched on during the day (AC on/off mode). The average indoor air thermal parameters, CO2 concentration and the PAQ value (in decipols) were elevated, while average PM1 concentration was lower in the AC on/off mode. A statistically significant (p PAQ values and CO2 concentrations (r = 0.66 and r = 0.59, respectively) in that AC mode. A significant negative correlation has been observed between T and PN and PM1 concentrations (r = -0.38 and r = -0.49, respectively). In the AC off mode the above relations between T and the particle concentrations were not that unequivocal. These findings may be of importance as they indicate that in certain AC operation modes the indoor air quality deteriorates along with the variation of the indoor air microclimate and room occupation. This, in turn, may adversely affect the comfort and productivity of the users of air conditioned premises.

  13. CALCULATION OF AIR ION REGIME IN THE CASE OF ARTIFICIAL AIR IONIZATION

    Directory of Open Access Journals (Sweden)

    BILIAIEV M. M.

    2015-10-01

    Full Text Available Purpose. One of the major tasks in the field of labor protection is providing of the necessary qualitative composition of air in the working areas of office and industrial spaces. In order to maintain the necessary air ion level in the air space premises, the artificial ionization of air is used often in the premises. At present in Ukraine analytical model are used for the calculation of air ion regime in premises, influencing on the formation process of air ions concentration field. An alternative solution is the use of CFD models, developing including the air jets aerodynamics in the premise, the presence of furniture, equipment, transfer of ions under an electric field, and other physical factors, determining intensity and shape of air ions concentration field in the premise. Methodology. Influence of air flow was taken into account in the development of CFD models for calculation of air ion regime in the apartment, caused by operation of ventilation, diffusion, electric field impact, as well as the interaction of different polarity ions with each other, and their interaction with dust particles. The proposed model of calculation of air ion regime in premises based on the use of aerodynamics, electrostatics and mass transfer levels. This model allows operatively to calculate air ions concentration field with the influence of the walls, floor, ceiling and obstacles on the process of air ions dispersion, the specific location of different polarity ions emission and their interaction in the premise and work areas in conditions of artificial air ionization. Results. The calculated data were obtained and on their base could be estimated the concentration of air ion anywhere in the premise with artificial air ionization. Ions concentration field, being calculated using this CFD model, as concentration field isolines is presented. Originality. The results of the air ion regime calculation in the premise are presented, based on numerical 2D CFD model

  14. Danger in the Air: Air Pollution and Cognitive Dysfunction.

    Science.gov (United States)

    Cipriani, Gabriele; Danti, Sabrina; Carlesi, Cecilia; Borin, Gemma

    2018-01-01

    Clean air is considered to be a basic requirement for human health and well-being. To examine the relationship between cognitive performance and ambient pollution exposure. Studies were identified through a systematic search of online scientific databases, in addition to a manual search of the reference lists from the identified papers. Air pollution is a multifaceted toxic chemical mixture capable of assaulting the central nervous system. Despite being a relatively new area of investigation, overall, there is mounting evidence implicating adverse effects of air pollution on cognitive function in both adults and children. Consistent evidence showed that exposure to air pollution, specifically exposure to particulate matter, caused poor age-related cognitive performance. Living in areas with high levels of air pollution has been linked to markers of neuroinflammation and neuropathology that are associated with neurodegenerative conditions such as Alzheimer's disease-like brain pathologies.

  15. Air Sensor Toolbox

    Science.gov (United States)

    Air Sensor Toolbox provides information to citizen scientists, researchers and developers interested in learning more about new lower-cost compact air sensor technologies and tools for measuring air quality.

  16. CityAir app: Mapping air-quality perception using people as sensors

    Science.gov (United States)

    Castell, Nuria; Fredriksen, Mirjam; Cole-Hunter, Thomas; Robinson, Johanna; Keune, Hans; Nieuwenhuijsen, Mark; Bartonova, Alena

    2016-04-01

    Outdoor air pollution is a major environmental health problem affecting all people in developed and developing countries alike. Ambient (outdoor) air pollution in both cities and rural areas was estimated to cause 3.7 million premature deaths worldwide in 2012. In modern society, people are expending an increasing amount of time in polluted urban environments, thus increasing their exposure and associated health responses. Some cities provide information about air pollution levels to their citizens using air quality monitoring networks. However, due to their high cost and maintenance, the density of the monitoring networks is very low and not capable to capture the high temporal and spatial variability of air pollution. Thus, the citizen lacks a specific answer to the question of "how the air quality is in our surroundings". In the framework of the EU-funded CITI-SENSE project the innovative concept of People as Sensors is being applied to the field of outdoor air pollution. This is being done in eight European cities, including Barcelona, Belgrade, Edinburgh, Haifa, Ljubljana, Oslo, Ostrava and Vienna. People as Sensors defines a measurement model, in which measurements are not only taken by hardware sensors, but in which also humans can contribute with their individual "measurements" such as their subjective perception of air quality and other personal observations. In order to collect the personal observations a mobile app, CityAir, has been developed. CityAir allows citizens to rate the air quality in their surroundings with colour at their current location: green if air quality is very good, yellow if air quality is good, orange if air quality is poor and red if air quality is very poor. The users have also the possibility of indicating the source of pollution (i.e. traffic, industry, wood burning) and writing a comment. The information is on-line and accessible for other app users, thus contributing to create an air-quality map based on citizens' perception

  17. Final Environmental Assessment for the First Air Force Air Operations Center, First Air Force Headquarters/Air Force Forces Center, and Highway 98 Overpass at Tyndall Air Force Base, Florida

    Science.gov (United States)

    2004-01-01

    no comments regarding the Draft Environmental Assessment for the First Air Force Operations Center, First Air Force Headquarters/Air Force Forces...COUNCIL ] No Comment BAY - BAY COUNTY No Final Comments Received ENVIRONMENTAL POLICY UNIT - OFFICE OF POLICY AND BUDGET, ENVIRONMENTAL POLICY UNIT NO ...CONSERVATION COMMISSION [ NO COMMENT BY BRIAN BARNETT ON 4/12/04. [STATE - FLORIDA DEPARTMENT OF STATE [ No Comment [TRANSPORTATION - FLORIDA DEPARTMENT

  18. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  19. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  20. Air pollution engineering

    Science.gov (United States)

    Maduna, Karolina; Tomašić, Vesna

    2017-11-01

    Air pollution is an environmental and a social problem which leads to a multitude of adverse effects on human health and standard of human life, state of the ecosystems and global change of climate. Air pollutants are emitted from natural, but mostly from anthropogenic sources and may be transported over long distances. Some air pollutants are extremely stable in the atmosphere and may accumulate in the environment and in the food chain, affecting human beings, animals and natural biodiversity. Obviously, air pollution is a complex problem that poses multiple challenges in terms of management and abatements of the pollutants emission. Effective approach to the problems of air pollution requires a good understanding of the sources that cause it, knowledge of air quality status and future trends as well as its impact on humans and ecosystems. This chapter deals with the complexities of the air pollution and presents an overview of different technical processes and equipment for air pollution control, as well as basic principles of their work. The problems of air protection as well as protection of other ecosystems can be solved only by the coordinated endeavors of various scientific and engineering disciplines, such as chemistry, physics, biology, medicine, chemical engineering and social sciences. The most important engineering contribution is mostly focused on development, design and operation of equipment for the abatement of harmful emissions into environment.

  1. Indoor Air Quality

    Science.gov (United States)

    ... protect yourself and your family. Learn more Air Quality at Work Workers should breathe easy while on the job, but worksites with poor air quality put employees at risk. Healthy air is essential ...

  2. Machine & electrical double control air dryer for vehicle air braking system

    Science.gov (United States)

    Zhang, Xuan; Yang, Liu; Wang, Xian Yan; Tan, Xiao Yan; Wang, Wei

    2017-09-01

    As is known to all, a vehicle air brake system, in which usually contains moisture. To solve the problem, it is common to use air dryer to dry compressed air effectively and completely remove the moisture and oil of braking system. However, the existing air dryer is not suitable for all commercial vehicles. According to the operational status of the new energy vehicles in the initial operating period, the structure design principle of the machine & electric control air dryer is expounded from the aspects of the structure and operating principle, research & development process.

  3. Algorithmic choices in WARP – A framework for continuous energy Monte Carlo neutron transport in general 3D geometries on GPUs

    International Nuclear Information System (INIS)

    Bergmann, Ryan M.; Vujić, Jasmina L.

    2015-01-01

    Highlights: • WARP, a GPU-accelerated Monte Carlo neutron transport code, has been developed. • The NVIDIA OptiX high-performance ray tracing library is used to process geometric data. • The unionized cross section representation is modified for higher performance. • Reference remapping is used to keep the GPU busy as neutron batch population reduces. • Reference remapping is done using a key-value radix sort on neutron reaction type. - Abstract: In recent supercomputers, general purpose graphics processing units (GPGPUs) are a significant faction of the supercomputer’s total computational power. GPGPUs have different architectures compared to central processing units (CPUs), and for Monte Carlo neutron transport codes used in nuclear engineering to take advantage of these coprocessor cards, transport algorithms must be changed to execute efficiently on them. WARP is a continuous energy Monte Carlo neutron transport code that has been written to do this. The main thrust of WARP is to adapt previous event-based transport algorithms to the new GPU hardware; the algorithmic choices for all parts of which are presented in this paper. It is found that remapping history data references increases the GPU processing rate when histories start to complete. The main reason for this is that completed data are eliminated from the address space, threads are kept busy, and memory bandwidth is not wasted on checking completed data. Remapping also allows the interaction kernels to be launched concurrently, improving efficiency. The OptiX ray tracing framework and CUDPP library are used for geometry representation and parallel dataset-side operations, ensuring high performance and reliability

  4. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  5. Photochemical air pollution

    International Nuclear Information System (INIS)

    Te Winkel, B.H.

    1992-01-01

    During periods of severe photochemical air pollution (smog) the industry in the Netherlands is recommended by the Dutch government to strongly reduce the emissions of air pollutants. For the electric power generating companies it is important to investigate the adequacy of this policy. The purpose of this investigation is to determine the contribution of electric power plants to photochemical air pollution and to assess the efficacy of emission reducing measures. A literature survey on the development of photochemical air pollution was carried out and modelled calculations concerning the share of the electric power plants to the photochemical air pollution were executed

  6. Air-water screen

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.I.; Kutepov, A.I.

    1980-12-08

    The air-water screen based on inventor's certificate No. 577364 contains horizontal water and air lines with water and air nozzles. The air line is situated inside the water line eccentrically and contracts it in the area of the nozzle, whose orifices are situated along the line of contact, while the orifices of the water nozzle are situated symmetrically relative to the air orifices and are located at an acute angle to them. To raise the protective properties, on the end of the water line is a lateral nozzle water distributor is an additional nozzle, connected to this container.

  7. THE USE OF AIR LAYERS IN BUILDING ENVELOPES FOR ENERGY SAVING DURING AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available Since there are no large natural energy resources in Belarus, energy savings ought to be a point of the special attention. With this regard it is important to develop modern ways of savings during the process of air conditioning inside new buildings with an air layer in the enclosure, especially in translucent ones. The system of ventilation of air layers in the enclosure of a building has been introduced in which air movement is caused by the gravitational and aerodynamic forces. It makes it possible to arrange further ventilation – a natural, forced or a hybrid one. With the purpose of increasing and streamlining natural draught the partitions are used separating the different parts of air layers. For natural ventilation with the use of gravitational forces the holes in the upper and lower parts of the partitions between adjacent air layers are applied. Natural ventilation in the holes of the partitions is regulated by movable shutters, blinds or other adjusting devices. For combined or forced air exchange between adjacent zones of air layers fans are used pumping air from the air layer zones with a higher temperature to zones of air layers with lower temperature and vice versa. When air exchange is forced, in order to intensify the infiltration of air into zones of air layers jets are laid on a hard surface. In order to cool a multi-layered enclosure of a building, where the movement of air between the air layers (that have been formed by internal partitions is being fulfilled by a natural, forced or combined mode, a part of the air or the total air processed inside the building (i.e. conditioned or non-conditioned air cooler as compared with the outside one is being sent to these strata. Combined or forced flow of the air processed inside the building into the air layers is done through the ducts associated with the output channels of the air conditioners. The internal partitions are equipped with the air valve hole.

  8. Simple air collectors for preheating fresh air

    NARCIS (Netherlands)

    Hensen, J.L.M.; Wit, de M.H.; Ouden, den C.

    1984-01-01

    In dwellings with mechanical ventilation systems the fresh air can easily be preheated by means of simple solar air systems. These can be an integral part of the building facade or roof and the costs are expected to be low. By means of computer experiments a large number of systems were evaluated.

  9. Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser

    Energy Technology Data Exchange (ETDEWEB)

    Hajidavalloo, E.; Eghtedari, H. [Mechanical Engineering Department, Shahid Chamran University, Golestan St., Ahvaz (Iran)

    2010-08-15

    Increasing the coefficient of performance of air conditioner with air-cooled condenser is a challenging problem especially in area with very hot weather conditions. Application of evaporatively cooled air condenser instead of air-cooled condenser is proposed in this paper as an efficient way to solve the problem. An evaporative cooler was built and coupled to the existing air-cooled condenser of a split-air-conditioner in order to measure its effect on the cycle performance under various ambient air temperatures up to 49 C. Experimental results show that application of evaporatively cooled air condenser has significant effect on the performance improvement of the cycle and the rate of improvement is increased as ambient air temperature increases. It is also found that by using evaporatively cooled air condenser in hot weather conditions, the power consumption can be reduced up to 20% and the coefficient of performance can be improved around 50%. More improvements can be expected if a more efficient evaporative cooler is used. (author)

  10. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...... floor heating system was simulated, the cooler ventilation air introduced to the room mixed well and created uniform conditions with a ventilation effectiveness of about 1.......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...

  11. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  12. Hazardous air pollutant handbook: measurements, properties, and fate in ambient air

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, C.W. (ed.); Gordon, S.M.; Kelly, T.J.; Holdren, M.W.; Mukund, R. [Battelle, Columbus, OH (United States)

    2002-07-01

    Focussing on the 188 hazardous air pollutants (HAPs) identified in the Title III of the US Clean Air Act Amendments, this work reviews the methods used to identify, measure, and locate the presence of toxics in ambient air. After a classification and characterization of the HAPs, the current status of ambient measurement methods are surveyed and categorized according to applicable, likely, and potential methods. The results of studies of ambient air concentrations of the HAPs are presented. Methods used to study atmospheric transformations of toxic air pollutants are reviewed and the concept of atmospheric lifetimes of HAPs is discussed.

  13. Controlled air incineration

    International Nuclear Information System (INIS)

    Seitz, K.A.

    1991-01-01

    From 1960 to 1970, incineration was recognized as an economical method of solid waste disposal with many incinerators in operation through the country. During this period a number of legislation acts began to influence the solid waste disposal industry, namely, the Solid Waste Disposal Act of 1965; Resource Conservation Recovery Act (RCRA) of 1968; Resource Recovery Act of 1970; and Clean Air Act of 1970. This period of increased environmental awareness and newly created regulations began the closure of many excess air incineration facilities and encouraged the development of new controlled air, also known as Starved-Air incinerator systems which could meet the more stringent air emission standards without additional emission control equipment. The Starved-Air technology initially received little recognition because it was considered unproven and radically different from the established and accepted I.I.A. standards. However, there have been many improvements and developments in the starved-air incineration systems since the technology was first introduced and marketed, and now these systems are considered the proven technology standard

  14. Oxidation behavior of stainless steel 430 and 441 at 800 C in single (air/air) and dual atmosphere (air/hydrogen) exposures

    Energy Technology Data Exchange (ETDEWEB)

    Rufner, J.; Gannon, P.; White, P.; Deibert, M.; Teintze, S. [Chemical and Biological Engineering, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States); Smith, R.; Chen, H. [Physics, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States)

    2008-02-15

    Intermediate temperature ({proportional_to}800 {sup o}C) planar solid oxide fuel cells (SOFCs) allow the use of ferritic stainless steel (FSS) interconnects. SOFC FSS interconnects are used to stack individual cells into series, and are simultaneously exposed to air on the cathode side and fuel on the anode side, creating a 'dual atmosphere' exposure. The thermally grown oxide (TGO) layers on the air side of FSSs 430 and 441 were analyzed as a function of simulated dual atmosphere exposures (moist air/moist hydrogen) for up to 300 h. FSS 430 showed some changes in oxidation behavior, with a slight Fe concentration increase and localized Fe{sub 2}O{sub 3} nodule formation observed in the dual atmosphere TGO layer relative to its single atmosphere (air/air) counterpart. Significantly accelerated and anomalous oxidation was observed with FSS 441 subjected to dual atmosphere exposures compared with air/air exposures. The TGO layer formed on the 441 exposed to air/air was comprised of Mn-rich, Cr and Fe-containing isomorphic spinel surface crystallites, with a Cr{sub 2}O{sub 3} (eskolaite)-based bottom layer, having a total TGO layer thickness of <2{mu} m after 300 h. In contrast, the TGO layer formed on 441 during dual atmosphere exposure was much faster-growing (>6{mu} m in 20 h) and exhibited a continuous, porous Fe{sub 2}O{sub 3}-rich surface layer with a relatively thin (<2{mu} m) sublayer of similar composition to the TGO layer formed during the air/air exposure. Spontaneous TGO layer spallation was also observed for the air side of 441 exposed to dual atmosphere for >100h. The observed oxidation behavior and TGO layer evolution of 441 in both air/air and dual atmosphere are presented, with possible mechanisms and implications discussed. (author)

  15. Air toxics and the 1990 Clean Air Act: Managing trace element emissions

    International Nuclear Information System (INIS)

    Chow, W.; Levin, L.; Miller, M.J.

    1992-01-01

    The US Environmental Protection Agency (EPA) has historically regulated air toxics (hazardous air pollutants) under Section 112 of the Clean Air Act. To date, EPA has established emission standards for 8 hazardous air pollutants (arsenic, asbestos, benzene, beryllium, mercury, radionuclides, coke oven emissions and vinyl chloride). The US electric utility industry was not determined to be a source category requiring regulation for any of the eight chemicals. Of the eight, radionuclides were the last species for which EPA established hazardous emissions standards. In this instance, EPA determined that the risks associated with electric utility fossil fuel power plant emissions were sufficiently low that they should not be regulated. However, the 1990 Clean Air Act Amendments require a new evaluation of the electric utility industry emissions of hazardous air pollutants. This paper summarizes the key features of the air toxics provisions of the Clean Air Act Amendments, describes EPRI's activities on the subject, and provides some preliminary insights from EPRI's research to date

  16. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  17. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    DEFF Research Database (Denmark)

    Nazaroff, W.; Weschler, Charles J.

    2004-01-01

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated...... by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals...... that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which...

  18. Large scale air monitoring: Biological indicators versus air particulate matter

    International Nuclear Information System (INIS)

    Rossbach, M.; Jayasekera, R.; Kniewald, G.

    2000-01-01

    Biological indicator organisms are widely used for monitoring and banking purposes since many years. Although the complexity of the interactions between bioorganisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Direct measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and uniform matrix characteristics of air particulates as a prerequisite for global monitoring of air pollution will be discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300 to 500 g each) from a number of hotels during a period of three to four months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per three months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichen such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Fig and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cr, Zn, and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10). (author)

  19. Air pollution and urban air quality management in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Santosa, Sri J. [Department of Chemistry, Faculty of Mathematics and Natural Sciences, Gadjah Mada University, Yogyakarta (Indonesia); Okuda, Tomoaki; Tanaka, Shigeru [Department of Applied Chemistry, Faculty of Science and Technology, Keio University, Yokohama (Japan)

    2008-06-15

    The trade-led industry and economic development after the Asian financial crisis a decade ago has been accelerated in Indonesia to improve the quality of life of its population. This rapid development of Indonesia was in fact heavily fueled by fossil fuels, especially oil, followed by natural gas and coal. The exploitation of fossil fuel in fueling the development resulted in significant environmental quality degradation. Air pollution is perhaps Indonesia's most severe environmental problem. Industry and transportation were the typical main sources of urban air pollutants. Moreover, Indonesia also failed to reach its original 2005 target for a complete phase-out of leaded gasoline. As a result, the level of Pb together with other pollutants such as CO, NO{sub x}, SO{sub 2}, and total suspended particulates has exceeded or at least approached the designated ambient air quality standards. The urban air pollution will not be lesser in extent, but surely will be more severe in the future. Unfortunately, the capability of the Indonesian authorities to manage the urban air quality is still very limited and the portion of the budget allocated to the improvement of urban air quality is still remarkably low, typically 1% of total. This is why the efforts to enhance the capability to manage the urban air quality could not be handled by the environmental authorities in Indonesia's cities themselves, but outside stimulation in the form of man power, consultant and equipment assistance along with financial support has been very important. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  20. AirCompare

    Data.gov (United States)

    U.S. Environmental Protection Agency — AirCompare contains air quality information that allows a user to compare conditions in different localities over time and compare conditions in the same location at...

  1. 12th Air Force > Home

    Science.gov (United States)

    Force AOR Travel Info News prevnext Slide show 76,410 pounds of food delivered to Haiti 12th Air Force the French Air Force, Colombian Air Force, Pakistan Air Force, Belgian Air Force, Brazilian Air Force

  2. Energy use, air infiltration, and indoor air quality in well-insulated residences

    International Nuclear Information System (INIS)

    Koontz, M.D.; Nagda, N.L.

    1989-01-01

    This paper reports two unoccupied bilevel houses of identical design and construction studied to determine the relationships among air exchange, energy consumption, and indoor air quality. The experimental house was retrofitted to increase building tightness and was equipped with an air-to-air heat exchanger; the control house was kept in its initial state of construction. Infiltration, energy, indoor air quality, and environmental parameters were monitored in both houses before and after the retrofit. It was found that the retrofit decreased air infiltration rates by nearly 25 percent, heating energy savings of 12 to 20 percent were achieved through the retrofit, and among the pollutants monitored, only radon and radon progeny increased in proportion to the reduced infiltration. Similarly, when the heat exchanger was operated, radon and radon progeny were the only pollutants reduced in proportion to the added air exchange

  3. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    Science.gov (United States)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  4. Air pollution

    OpenAIRE

    MacKenbach, JP; Henschel, S; Goodman, P; McKee, M

    2013-01-01

    The human costs of air pollution are considerable in Jordan. According to a report published in 2000 by the World Bank under the Mediterranean Environmental Technical Assistance Program (METAP), approximately 600 people die prematurely each year in Jordan because of urban pollution. 50-90% of air pollution in Jordanian towns is caused by road traffic. Readings taken in 2007 by Jordanian researchers showed that levels of black carbon particles in the air were higher in urban areas (caused by v...

  5. Air quality management: challenges and solutions in delivering air quality action plans

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, C.I.; Longhurst, J.W.S.; Woodfield, N.K.

    2000-07-01

    The Air Quality Strategy for England, Scotland, Wales and Northern Ireland (DETR, 2001) has the aim of showing how improved local air quality in the UK may be delivered. Through a process of reviewing and assessing local air quality in both urban and rural localities, a clear picture is emerging of areas of the UK where air quality objectives are not likely to be met. The next challenge will be the identification of the required actions and new ways of working to achieve specific air quality objectives. The declaration of air quality management areas, where objectives are not predicted to be met by their target years, involves co-ordinated local action and collaborative working, which can only be effective with support across local authority departments and external stake holders. This paper provides a background to the relevant legislation underpinning, local air quality management and summarises the review and assessment process. It then comments on future directions in relation to the designation of Air Quality Management Areas and considers the requirements of action plans to deliver the goal of cleaner air in the UK. It is concluded that the UK has developed a highly sophisticated system of air quality management over a relatively short period of time, and with it has brought a new way of local authority working. The challenge of the next stage of the process is likely to be in implementing cost effective and proportional solutions to identified problems at the local level. (Author)

  6. Air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, W; Mainwaring, S J

    1984-01-01

    This book deals with the nature of air pollution. The numerous sources of unwanted gases and dust particles in the air are discussed. Details are presented of the effects of pollutants on man, animals, vegetation and on inanimate materials. Methods used to measure, monitor and control air pollution are presented. The authors include information on the socio-economic factors which impinge on pollution control and on the problems the future will bring as methods of generating energy change and industries provide new sources of pollutants.

  7. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  8. Pollution prevention for cleaner air: EPA's air and energy engineering research laboratory

    International Nuclear Information System (INIS)

    Shaver, E.M.

    1992-01-01

    The article discusses the role of EPA's Air and Energy Engineering Research Laboratory (AEERL) in pollution prevention research for cleaner air. For more than 20 years, AEERL has been conducting research to identify control approaches for the pollutants and sources which contribute to air quality problems. The Laboratory has successfully developed and demonstrated cost-effective sulfur dioxide, nitrogen oxides, and particulate control technologies for fossil fuel combustion sources. More recently, it has expanded its research activities to include indoor air quality, radon, organic control, stratospheric ozone depletion, and global warming. AEERL also develops inventories of air emissions of many types. Over the last several years, it has made substantial efforts to expand research on pollution prevention as the preferred choice for air emissions reduction

  9. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Energy Technology Data Exchange (ETDEWEB)

    El-Awad, Mohamed M. [Mechanical Engineering Department, the University of Khartoum, P.O. Box 321 Khartoum (Sudan)

    2011-07-01

    The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min) air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  10. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  11. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  12. Air Quality of Beijing and Impacts of the New Ambient Air Quality Standard

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2015-08-01

    Full Text Available Beijing has been publishing daily reports on its air quality since 2000, and while the air pollution index (API shows that the air quality has improved greatly since 2000, this is not the perception of Beijing’s residents. The new national ambient air quality standard (NAAQS-2012, which includes the monitoring of PM2.5, has posed stricter standards for evaluating air quality. With the new national standard, the air quality in Beijing is calculated using both NAAQS-2012 and the previous standard. The annual attainment rate has dropped from 75.5% to 50.7%. The spatial analysis of air quality shows that only a background station could attain the national standard, while urban and suburban stations exceed the national standard. Among the six pollutants included in the NAAQS-2012, PM2.5 is the major contributor to the air quality index (AQI comparing with the five other pollutants. The results indicate that under previous NAAQS without PM2.5 monitoring, the air quality has improved greatly in the past decade.  By considering PM2.5, the air quality attainment has dropped greatly. Furthermore, a great effort is needed for local government to bring down the PM2.5 concentration.

  13. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  14. Influence of local air velocity from air conditioner evaluated by salivary and skin biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Masaki; Takahashi, Takayuki; Yoshino, Yuichiro; Sasaki, Makoto [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Nishimiya, Hajime [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2010-11-15

    The purpose of this paper is to reveal both the psychosomatic and the physical effects of local air velocity from an air conditioner using biomarkers which can be collected noninvasively. Salivary {alpha}-amylase activity (SAA) and salivary cortisol were used as the indexes of psychosomatic effects. The total protein (TP) collected from stratum corneum was used as an index of the physical condition of dry skin. A continuous experiment over a 5 days period in summer was conducted using 8 healthy young male adults for 2-types of airflow conditioners, a whole ceiling-type air conditioner (without local air velocity) and a normal-type air conditioner (with local air velocity). The subjects felt cool, windy, dry and uncomfortable when under the normal-type air conditioner as determined in a subjective evaluation. The SAA under the normal-type air conditioner fluctuated more widely than with the whole ceiling-type air conditioner. The level of salivary cortisol decreased more in a day under the normal-type air conditioner than with the whole ceiling-type air conditioner. These results showed that reducing local air velocity may provide more healthy psychosomatic conditions over the long-term. Moreover, the TP of a drying-exposed skin area showed a significant change during this experiment whereas the TP of drying-protected area was relatively unchanged. It was indicated that one week's exposure to local air velocity conditions possibly influences the drying of facial skin. Thus, air movement at low velocity can be provides more comfortable conditions not only psychosomatically but also physically. (author)

  15. Beyond Close Air Support. Forging a New Air-Ground Partnership

    Science.gov (United States)

    2005-01-01

    the "eth- nic cleansing." Despite months of effort, air attacks did little damage to Serb forces. Those in Kosovo not only survived, they even...Blue Moon: Airmen in Theater Command, CADRE Paper No. 7, Air University Press, Maxwell Air Force Base, 2000. Biddle , Stephen, Afghanistan and the...Future of Warfare: Implications for Army and Defense Policy, Carlisle, PA: Strategic Studies Institute, U.S. Army War College, 2002. Biddle , Stephen

  16. Air Quality | Air Quality Planning & Standards | US EPA

    Science.gov (United States)

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  17. Help From Above: Air Force Close Air Support of the Army. 1946-1973

    Science.gov (United States)

    2003-01-01

    support as but one ele- ment within a larger package called tactical air support challenges the researcher . Even though close air support is but one of...of the prewar gaps in the close air support picture. Of all the close air support developments that emerged from the war, however, airmen looked upon...to reduce the AAF’s impressive World War II close air support capabilities to a token force in the short space of five years, these budgetary

  18. Air lasing

    CERN Document Server

    Cheng, Ya

    2018-01-01

    This book presents the first comprehensive, interdisciplinary review of the rapidly developing field of air lasing. In most applications of lasers, such as cutting and engraving, the laser source is brought to the point of service where the laser beam is needed to perform its function. However, in some important applications such as remote atmospheric sensing, placing the laser at a convenient location is not an option. Current sensing schemes rely on the detection of weak backscattering of ground-based, forward-propagating optical probes, and possess limited sensitivity. The concept of air lasing (or atmospheric lasing) relies on the idea that the constituents of the air itself can be used as an active laser medium, creating a backward-propagating, impulsive, laser-like radiation emanating from a remote location in the atmosphere. This book provides important insights into the current state of development of air lasing and its applications.

  19. Microfluidic liquid-air dual-gradient chip for synergic effect bio-evaluation of air pollutant.

    Science.gov (United States)

    Liu, Xian-Jun; Hu, Shan-Wen; Xu, Bi-Yi; Zhao, Ge; Li, Xiang; Xie, Fu-Wei; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-05-15

    In this paper, a novel prototype liquid-air dual gradient chip is introduced, which has paved the way for effective synergic effect bio-evaluation of air pollutant. The chip is composed of an array of the agarose liquid-air interfaces, top air gradient layer and bottom liquid gradient layer. The novel agarose liquid-air interface allows for non-biased exposure of cells to all the substances in the air and diffusive interactions with the liquid phase; while the dual liquid-air gradient provides powerful screening abilities, which well reduced errors, saved time and cost from repeated experiment. Coupling the two functions, the chip subsequently facilitates synergic effect evaluation of both liquid and air factors on cells. Here cigarette smoke was taken as the model air pollutant, and its strong synergic effects with inflammatory level of A549 lung cancer cells on their fate were successfully quantified for the first time. These results well testified that the proposed dual-gradient chip is powerful and indispensable for bio-evaluation of air pollutant. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Long-term Changes in Extreme Air Pollution Meteorology and the Implications for Air Quality.

    Science.gov (United States)

    Hou, Pei; Wu, Shiliang

    2016-03-31

    Extreme air pollution meteorological events, such as heat waves, temperature inversions and atmospheric stagnation episodes, can significantly affect air quality. Based on observational data, we have analyzed the long-term evolution of extreme air pollution meteorology on the global scale and their potential impacts on air quality, especially the high pollution episodes. We have identified significant increasing trends for the occurrences of extreme air pollution meteorological events in the past six decades, especially over the continental regions. Statistical analysis combining air quality data and meteorological data further indicates strong sensitivities of air quality (including both average air pollutant concentrations and high pollution episodes) to extreme meteorological events. For example, we find that in the United States the probability of severe ozone pollution when there are heat waves could be up to seven times of the average probability during summertime, while temperature inversions in wintertime could enhance the probability of severe particulate matter pollution by more than a factor of two. We have also identified significant seasonal and spatial variations in the sensitivity of air quality to extreme air pollution meteorology.

  1. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  2. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  3. 14 CFR 234.13 - Reports by air carriers on incidents involving animals during air transport.

    Science.gov (United States)

    2010-01-01

    ... involving animals during air transport. 234.13 Section 234.13 Aeronautics and Space OFFICE OF THE SECRETARY... REPORTS § 234.13 Reports by air carriers on incidents involving animals during air transport. (a) Any air... during air transport provided by the air carrier. (b) The report shall be made in the form and manner set...

  4. Effects of open-air temperature on air temperature inside biological safety cabinet.

    Science.gov (United States)

    Umemura, Masayuki; Shigeno, Katsuro; Yamamura, Keiko; Osada, Takashi; Soda, Midori; Yamada, Kiyofumi; Ando, Yuichi; Wakiya, Yoshifumi

    2011-02-14

    In Japan, biological safety cabinets (BSCs) are normally used by medical staff while handling antineoplastic agents. We have also set up a class II B2 BSC at the Division of Chemotherapy for Outpatients. The air temperature inside this BSC, however, decreases in winter. We assumed that this decrease is caused by the intake of open-air. Therefore, we investigated the effects of low open-air temperature on the BSC temperature and the time of admixtures of antineoplastic agents. The studies were conducted from January 1 to March 31, 2008. The outdoor air temperature was measured in the shade near the intake nozzle of the BSC and was compared with the BSC temperature. The correlation between the outdoor air temperature and the BSC temperature, the dissolution time of cyclophosphamide (CPA) and gemcitabine (GEM), and accurate weight measurement of epirubicin (EPI) solution were investigated for low and normal BSC temperatures. The BSC temperature was correlated with the open-air temperature for open-air temperatures of 5-20°C (p air is drawn from outdoors. We showed that the BSC temperature affects the dissolution rate of antineoplastic agents. Further, we suggested that the BSC temperature drop might delay the affair of the admixtures of antineoplastic agents and increase the waiting time of outpatients for chemotherapy.

  5. Comparison of desiccant air conditioning systems with different indirect evaporative air coolers

    International Nuclear Information System (INIS)

    Pandelidis, Demis; Anisimov, Sergey; Worek, William M.; Drąg, Paweł

    2016-01-01

    Highlights: • A numerical study of desiccant air conditioning systems is presented. • The ε-NTU model is used for the analysis. • Different arrangements of the desiccant systems were compared. • The systems were compared under different operating conditions. - Abstract: This paper presents a numerical analysis of three desiccant air-conditioning systems equipped with different indirect evaporative air coolers: (1) the cross-flow Maisotsenko cycle heat and mass exchanger (HMX), (2) the regenerative counter-flow Maisotsenko cycle heat and mass exchanger and (3) the standard cross-flow evaporative air cooler. To analyze the desiccant wheel and the indirect evaporative air coolers, the modified ε-NTU-model was used. The simulations were performed under assumption that the desiccant wheel is regenerated with air heated to relatively low temperature values (50–60 °C), which can be produced with solar panels in typical moderate climatic conditions. It was established that the main advantage of the presented solutions is that they can provide comfort conditions even with less effective dehumidification. The different systems were compared under variable selected operational factors (i.e. inlet air temperature, humidity and regeneration air temperature). The analysis allowed establishing the advantages and disadvantages of presented solutions and allowed estimating their application potential.

  6. A review of air exchange rate models for air pollution exposure assessments.

    Science.gov (United States)

    Breen, Michael S; Schultz, Bradley D; Sohn, Michael D; Long, Thomas; Langstaff, John; Williams, Ronald; Isaacs, Kristin; Meng, Qing Yu; Stallings, Casson; Smith, Luther

    2014-11-01

    A critical aspect of air pollution exposure assessments is estimation of the air exchange rate (AER) for various buildings where people spend their time. The AER, which is the rate of exchange of indoor air with outdoor air, is an important determinant for entry of outdoor air pollutants and for removal of indoor-emitted air pollutants. This paper presents an overview and critical analysis of the scientific literature on empirical and physically based AER models for residential and commercial buildings; the models highlighted here are feasible for exposure assessments as extensive inputs are not required. Models are included for the three types of airflows that can occur across building envelopes: leakage, natural ventilation, and mechanical ventilation. Guidance is provided to select the preferable AER model based on available data, desired temporal resolution, types of airflows, and types of buildings included in the exposure assessment. For exposure assessments with some limited building leakage or AER measurements, strategies are described to reduce AER model uncertainty. This review will facilitate the selection of AER models in support of air pollution exposure assessments.

  7. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  8. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  9. Integrating air-related health surveillance into air quality management: perceptions and practicalities

    CSIR Research Space (South Africa)

    Wright, C

    2012-06-01

    Full Text Available Health surveillance is presently not an integral part of air quality management in South Africa, although ambient air pollution standards are derived from health effects of personal exposure. In a survey to air quality officials and environmental...

  10. Analysis of Direct Outdoor Air Cooling Efficency for Combined Variable Air Volume Air-conditioning System in Stores in Cold Climates of China

    OpenAIRE

    Luo, Zhiwen

    2006-01-01

    Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive ...

  11. Local Air Quality Conditions and Forecasts

    Science.gov (United States)

    ... Monitor Location Archived Maps by Region Canada Air Quality Air Quality on Google Earth Links A-Z About AirNow AirNow International Air Quality Action Days / Alerts AirCompare Air Quality Index (AQI) ...

  12. AIR NCO's AND AIRMEN

    African Journals Online (AJOL)

    D.F.C. o Proceeded to Cape Town 9:5:22. Left Cape Town for. African Protectorate 25:2:22. J Left for South West African Protectorate 25:2:22. [ Left for South West African Protectorate. 1:6:22. Colonel: Director of Air Services. Air Directorate. 6th June 1922. SOUTH AFRICAN AIR FORCE. NOMINAL ROLL OF AIR W.O.'s,.

  13. Air quality

    International Nuclear Information System (INIS)

    1995-01-01

    This chapter of the 'Assessment of the state of the environment in Lebanon' describes the air quality and identifies the most important air quality issues. Baseline information about the factors affecting dispersion and the climate of Lebanon presents as well and overall estimation of total emissions in Lebanon. Emissions from vehicles, electricity and power plants generation are described. Industrial emitters of air pollutants are described for each kind of industry i.e.cement plants, Selaata fertilizer factory, sugar-beet factory, refineries and for those derived from the use of leaded fuel . Impact of economic and human activities on air quality in Lebanon (especially in Beirut and Tripoli) are quantified by quantities of CO 2 , SO 2 , NO x , total suspended particulates(TSP), deposition and their environmental effects on health. In abscence of emissions monitoring, data available are expressed in terms of fuel use, output and appropriate empirical factors, national output and workfores sizes. Finally key issues and some potential mitigation /management approaches are presented

  14. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  15. Clearing the air. Air quality modelling for policy support

    NARCIS (Netherlands)

    Hendriks, C.

    2017-01-01

    The studies presented in this thesis were performed to provide policy makers with more accurate information about the sources of air pollution and the possible consequences of future developments on air quality. This enables policy makers to make better informed decisions when formulating policies

  16. 77 FR 30087 - Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards

    Science.gov (United States)

    2012-05-21

    ... and 81 Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards; Implementation of the 2008 National Ambient Air Quality Standards for Ozone: Nonattainment Area Classifications...-9668-2] RIN 2060-AP37 Air Quality Designations for the 2008 Ozone National Ambient Air Quality...

  17. Applications Using AIRS Data

    Science.gov (United States)

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  18. Significance of air humidity and air velocity for fungal spore release into the air

    Science.gov (United States)

    Pasanen, A.-L.; Pasanen, P.; Jantunen, M. J.; Kalliokoski, P.

    Our previous field studies have shown that the presence of molds in buildings does not necessarily mean elevated airborne spore counts. Therefore, we investigated the release of fungal spores from cultures of Aspergillus fumigatus, Penicillium sp. and Cladosporium sp. at different air velocities and air humidities. Spores of A. fumigatus and Penicillium sp. were released from conidiophores already at air velocity of 0.5 ms -1, whereas Cladosporium spores required at least a velocity of 1.0 ms -1. Airborne spore counts of A. fumigatus and Penicillium sp. were usually higher in dry than moist air, being minimal at relative humidities (r.h.) above 70%, while the effect of r.h. on the release of Cladosporium sp. was ambivalent. The geometric mean diameter of released spores increased when the r.h. exceeded a certain level which depends on fungal genus. Thus, spores of all three fungi were hygroscopic but the hygroscopicity of various spores appeared at different r.h.-ranges. This study indicates that spore release is controlled by external factors and depends on fungal genus which can be one reason for considerable variation of airborne spore counts in buildings with mold problems.

  19. The microbiological quality of air improves when using air conditioning systems in cars.

    Science.gov (United States)

    Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F

    2010-06-01

    Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.

  20. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  1. Air pollution knows no boundaries: defining air catchment areas and making sense of physical and political boundaries in air quality management

    CSIR Research Space (South Africa)

    Scott, G

    2005-10-01

    Full Text Available Topics under discussion: Scales of transport and turbulence in the atmosphere; Examples of global, regional and local scale transports – concepts of an “air catchment”; Defining air quality management zones - international practice; Defining air...

  2. Kinetics of NO formation and decay in nanosecond pulse discharges in Air, H2-Air, and C2H4-Air mixtures

    International Nuclear Information System (INIS)

    Burnette, David; Shkurenkov, Ivan; Adamovich, Igor V; Lempert, Walter R

    2016-01-01

    Time-resolved, absolute NO and N atom number densities are measured by NO Laser Induced Fluorescence (LIF) and N Two-Photon Absorption LIF in a diffuse plasma filament, nanosecond pulse discharge in dry air, hydrogen-air, and ethylene-air mixtures at 40 Torr, over a wide range of equivalence ratios. The results are compared with kinetic modeling calculations incorporating pulsed discharge dynamics, kinetics of vibrationally and electronically excited states of nitrogen, plasma chemical reactions, and radial transport. The results show that in air afterglow, NO decay occurs primarily by the reaction with N atoms, NO  +  N  →  N 2   +  O. In the presence of hydrogen, this reaction is mitigated by reaction of N atoms with OH, N  +  OH  →  NO  +  H, resulting in significant reduction of N atom number density in the afterglow, additional NO production, and considerably higher NO number densities. In fuel-lean ethylene-air mixtures, a similar trend (i.e. N atom concentration reduction and NO number density increase) is observed, although [NO] increase on ms time scale is not as pronounced as in H 2 -air mixtures. In near-stoichiometric and fuel-lean ethylene-air mixtures, when N atom number density was below detection limit, NO concentration was measured to be lower than in air plasma. These results suggest that NO kinetics in hydrocarbon-air plasmas is more complex compared to air and hydrogen-air plasmas, additional NO reaction pathways may well be possible, and their analysis requires further kinetic modeling calculations. (paper)

  3. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    Directory of Open Access Journals (Sweden)

    Daniela Pinheiro da Silva

    2013-10-01

    Full Text Available Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acquired infections – HAI – as the air can be a potential source of infection, as well as assess the exposure of professionals and patients to different pollutants. Material and Methods: A literature review was performed in the LILACS, MEDLINE, SCIELO, SCIENCE DIRECT databases, CAPES thesis database and Ministry of Health – Brazil, including studies published between 1982 and 2008. The literature search was grouped according to the thematic focus, as follows: ventilation, maintenance and cleaning of systems that comprehend the environmental quality standard. Discussion and Conclusion: Outbreaks of hospital-acquired infections associated with Aspergillus, Acinetobacter, Legionella, and other genera such as Clostridium and Nocardia, which were found in air conditioners, were observed, thus indicating the need for air-conditioning quality control in these environments.

  4. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  5. Air pollution control in India

    International Nuclear Information System (INIS)

    Jain, S.K.

    1995-01-01

    Prior to rapid spurt in industrialization in India, people were used to inhale pure air containing about 78% nitrogen, 21% oxygen and some carbon dioxide. But afterwards this composition of pure air was disturbed as a result of increased economic activities. Air, now a days also contains sulphur dioxide, carbon monoxide, nitrogen oxides etc., etc. which are extremely harmful for human health. Virulence of air pollution was realised in late eighties after Bhopal Gas Tragedy (BGT) and an effective air quality management started taking shape in India afterwards. The basic components of air quality management are legislation and regulations, emission inventory, air quality standards and monitoring, air dispersion models and installation of pollution control equipment which are being discussed in this paper. (author). 15 refs., 5 tabs

  6. Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange

    Science.gov (United States)

    Haynes, Brian D.

    2015-01-01

    Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange is a two-year research effort to visualize the U. S. aviation industry at a point 50 years in the future, and to define potential communication solutions to meet those future data exchange needs. The research team, led by XCELAR, was tasked with identifying future National Airspace System (NAS) scenarios, determining requirements and functions (including gaps), investigating technical and business issues for air, ground, & air-to-ground interactions, and reporting on the results. The project was conducted under technical direction from NASA and in collaboration with XCELAR's partner, National Institute of Aerospace, and NASA technical representatives. Parallel efforts were initiated to define the information exchange functional needs of the future NAS, and specific communication link technologies to potentially serve those needs. Those efforts converged with the mapping of each identified future NAS function to potential enabling communication solutions; those solutions were then compared with, and ranked relative to, each other on a technical basis in a structured analysis process. The technical solutions emerging from that process were then assessed from a business case perspective to determine their viability from a real-world adoption and deployment standpoint. The results of that analysis produced a proposed set of future solutions and most promising candidate technologies. Gap analyses were conducted at two points in the process, the first examining technical factors, and the second as part of the business case analysis. In each case, no gaps or unmet needs were identified in applying the solutions evaluated to the requirements identified. The future communication solutions identified in the research comprise both specific link technologies and two enabling technologies that apply to most or all specific links. As a result, the research resulted in a new analysis approach, viewing the

  7. Iron-Air Rechargeable Battery

    Science.gov (United States)

    Narayan, Sri R. (Inventor); Prakash, G.K. Surya (Inventor); Kindler, Andrew (Inventor)

    2014-01-01

    Embodiments include an iron-air rechargeable battery having a composite electrode including an iron electrode and a hydrogen electrode integrated therewith. An air electrode is spaced from the iron electrode and an electrolyte is provided in contact with the air electrode and the iron electrodes. Various additives and catalysts are disclosed with respect to the iron electrode, air electrode, and electrolyte for increasing battery efficiency and cycle life.

  8. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  9. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  10. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  11. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  12. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  13. Air Pollution and Stroke.

    Science.gov (United States)

    Lee, Kuan Ken; Miller, Mark R; Shah, Anoop S V

    2018-01-01

    The adverse health effects of air pollution have long been recognised; however, there is less awareness that the majority of the morbidity and mortality caused by air pollution is due to its effects on the cardiovascular system. Evidence from epidemiological studies have demonstrated a strong association between air pollution and cardiovascular diseases including stroke. Although the relative risk is small at an individual level, the ubiquitous nature of exposure to air pollution means that the absolute risk at a population level is on a par with "traditional" risk factors for cardiovascular disease. Of particular concern are findings that the strength of this association is stronger in low and middle income countries where air pollution is projected to rise as a result of rapid industrialisation. The underlying biological mechanisms through which air pollutants exert their effect on the vasculature are still an area of intense discussion. A greater understanding of the effect size and mechanisms is necessary to develop effective strategies at individual and policy levels to mitigate the adverse cardiovascular effects of air pollution.

  14. Air Quality at Your Street

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Becker, Thomas; Ketzel, Matthias

    Citizens are frequently concerned about the air quality where they live, where they go to work, where their children go to kindergarten or where they want to move to. Municipalities may also have an interest in location based air quality information e.g. in relation to screening of complaints from...... concerned citizents, or in the context of localization of institutions, etc. The purpose of the project ‘Air Quality at Your Street’ is to create interactive air quality maps on the internet using webGIS to illustrate the geographical variation of air quality in Denmark for selected health related air...... pollutants. The maps show annual means of NO2, PM2.5 or PM10 for 2012. The user interface presents modelled air quality data on a map where the user can select map view, pan, zoom in and out, etc. It is also possible to get the air quality for a particular address by entering a specific address. Air quality...

  15. Optimizing the Air Dissolution Parameters in an Unpacked Dissolved Air Flotation System

    Directory of Open Access Journals (Sweden)

    Adam Dassey

    2011-12-01

    Full Text Available Due to the various parameters that influence air solubility and microbubble production in dissolved air flotation (DAF, a multitude of values that cover a large range for these parameters are suggested for field systems. An unpacked saturator and an air quantification unit were designed to specify the effects of power, pressure, temperature, hydraulic retention time, and air flow on the DAF performance. It was determined that a pressure of 621 kPa, hydraulic retention time of 18.2 min, and air flow of 8.5 L/h would be the best controlled parameters for maximum efficiency in this unit. A temperature of 7 °C showed the greatest microbubble production, but temperature control would not be expected in actual application. The maximum microbubble flow from the designed system produced 30 mL of air (±1.5 per L of water under these conditions with immediate startup. The maximum theoretical dissolved air volume of 107 mL (±6 was achieved at a retention time of 2 h and a pressure of 621 kPa. To isolate and have better control over the various DAF operational parameters, the DAF unit was operated without the unsaturated flow stream. This mode of operation led to the formation of large bubbles at peak bubble production rates. In a real-world application, the large bubble formation will be avoided by mixing with raw unsaturated stream and by altering the location of dissolved air output flow.

  16. Health Effects of Air Pollution

    Science.gov (United States)

    ... Health effects of air pollution Health effects of air pollution Breathing air that is not clean can hurt ... important to know about the health effects that air pollution can have on you and others. Once you ...

  17. Interactions between particulate air pollution and temperature in air pollution mortality time series studies

    International Nuclear Information System (INIS)

    Roberts, Steven

    2004-01-01

    In many community time series studies on the effect of particulate air pollution on mortality, particulate air pollution is modeled additively. In this study, we investigated the interaction between daily particulate air pollution and daily mean temperature in Cook County, Illinois and Allegheny County, Pennsylvania, using data for the period 1987-1994. This was done through the use of joint particulate air pollution-temperature response surfaces and by stratifying the effect of particulate air pollution on mortality by temperature. Evidence that the effect of particulate air pollution on mortality may depend on temperature is found. However, the results were sensitive to the number of degrees of freedom used in the confounder adjustments, the particulate air pollution exposure measure, and how the effects of temperature on mortality are modeled. The results were less sensitive to the estimation method used--generalized linear models and natural cubic splines or generalized additive models and smoothing splines. The results of this study suggest that in community particulate air pollution mortality time series studies the possibility of an interaction between daily particulate air pollution and daily mean temperature should be considered

  18. Comparison of personal air samplers and static air samplers

    International Nuclear Information System (INIS)

    Carter, M.W.; Lumsden, B.

    1979-01-01

    The authors demonstrate that radioactive air contamination levels calculated from PAS results will always be higher than air contamination levels calculated from SAS results, other conditions being equal. The most probable explanation seems to be in a relationship between the sampling velocity and the particle size of the dust sampled

  19. Desalinasi Air Laut Berbasis Energi Surya Sebagai Alternatif Penyediaan Air Bersih

    Directory of Open Access Journals (Sweden)

    I Gede Yogi Dewantara

    2018-03-01

    Full Text Available Penelitian ini berkonsentrasi pada kemampuan alat desalinasi tipe solar still dalam menyerap energi kalor matahari dan penggunaannya dalam proses kondensasi guna memproduksi air tawar untuk keperluan masyarakat. Alat desalinasi ini terdiri dari kotak distiller dengan plat absorber dan kain yang terdapat di dalamnya, serta kaca sebagai pentransmisian. Sistem kerja berawal dari air diteteskan melalui pipa dan jatuh pada kain yang akan menyerap air. Radiasi matahari akan memanaskan plat absober melalui kaca kemudian panas plat memanaskan air pada kain hingga menjadi uap dan menempel pada permukaan dalam kaca hingga terkonsensasi menjadi air suling. Pengukuran volume minimal dan maksimal alat sebesar 5 lt dan 7 lt dilakukan selama 4 hari. Melalui penelitian ini dapat disimpulkan bahwa intensitas matahari telah ada saat cahaya matahari mulai terlihat pada pukul 6 pagi dan difusi energi kalor matahari telah mulai dimanfaatkan pada waktu tersebut. Akan tetapi kinerja alat desalinasi masih sangat rendah, hal ini terlihat dari angka efisiensi yang hanya mencapai 4,45%.

  20. Perception of cabin air quality in airline crew related to air humidification, on intercontinental flights.

    Science.gov (United States)

    Lindgren, T; Norbäck, D; Wieslander, G

    2007-06-01

    The influence of air humidification in aircraft, on perception of cabin air quality among airline crew (N = 71) was investigated. In-flight investigations were performed in the forward part and in the aft part on eight intercontinental flights with one Boeing 767 individually, equipped with an evaporation humidifier combined with a dehumidifying unit, to reduce accumulation of condensed water in the wall construction. Four flights had the air humidification active when going out, and turned off on the return flight. The four others had the inverse humidification sequence. The sequences were randomized, and double blind. Air humidification increased relative air humidity (RH) by 10% in forward part, and by 3% in aft part of the cabin and in the cockpit. When the humidification device was active, the cabin air was perceived as being less dry (P = 0.008), and fresher (P = 0.002). The mean concentration of viable bacteria (77-108 cfu/m(3)), viable molds (74-84 cfu/m(3)), and respirable particles (1-8 microg/m3) was low, both during humidified and non-humidified flights. On flights with air humidification, there were less particles in the forward part of the aircraft (P = 0.01). In conclusion, RH can be slightly increased by using ceramic evaporation humidifier, without any measurable increase of microorganisms in cabin air. The cabin air quality was perceived as being better with air humidification. PRACTICAL IMPLICATION: Relative air humidity is low (10-20%) during intercontinental flights, and can be increased by using ceramic evaporation humidifier, without any measurable increase of microorganism in cabin air. Air humidification could increase the sensation of better cabin air quality.

  1. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  2. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  3. Baltimore Air Toxics Study (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, D.A. [Sullivan Environmental Consulting, Inc., Alexandria, VA (United States)

    1996-12-31

    The Baltimore Air Toxics Study is one of the three urban air toxics initiatives funded by EPA to support the development of the national air toxics strategy. As part of this project, the Air Quality Integrated Management System (AIMS) is under development. AIMS is designed to bring together the key components of urban air quality management into an integrated system, including emissions assessment, air quality modeling, and air quality monitoring. Urban area source emissions are computed for a wide range of pollutants and source categories, and are joined with existing point source emissions data. Measured air quality data are used to evaluate the adequacy of the emissions data and model treatments as a function of season, meteorological parameters, and daytime/nighttime conditions. Based on tested model performance, AIMS provides the potential to improve the ability to predict air quality benefits of alternative control options for criteria and toxic air pollutants. This paper describes the methods used to develop AIMS, and provides examples from its application in the Baltimore metropolitan area. The use of AIMS in the future to enhance environmental management of major industrial facilities also will be addressed in the paper.

  4. The role of open-air inhalatoria in the air quality improvement in spa towns.

    Science.gov (United States)

    Burkowska-But, Aleksandra; Kalwasińska, Agnieszka; Brzezinska, Maria Swiontek

    2014-08-01

    The present study was aimed at evaluating microbiological contamination of air in Ciechocinek and Inowrocław - Polish lowland spa towns. Additionally, the impact of open-air inhalatoria on the quality of air was evaluated. Air samples were collected seasonally in the urban areas, in the recreation areas and in the vicinity of inhalatoria in both towns using impaction. The numbers of mesophilic bacteria, staphylococci, hemolytic bacteria and actinomycetes were determined on media according to the Polish Standard PN-86/Z-04111/02. The number of moulds was determined on media according to the Polish Standard PN-86/Z-04111/03. While the highest numbers of microorganisms were noted at the sites located in the urban areas, the lowest numbers were noted in the vicinity of the open-air inhalatoria. In all the investigated air samples the values of bioaerosol concentrations were below the recommended TLVs (≤ 5000 CFU×m(-3) for both bacteria and fungi in outdoor environments). Location of the sampling site was invariably a decisive factor in determining the number of microorganisms in the air. The aerosol which is formed in the open-air inhalatoria has a positive influence on microbiological air quality. Owing to a unique microclimate and low air contamination, Ciechocinek and Inowrocław comply with all necessary requirements set for health resorts specializing in treating upper respiratory tract infections.

  5. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  6. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  7. Liberalisation of air cargo transport

    Science.gov (United States)

    2002-05-02

    Over a period of many years, international air cargo demand has continued to increase more rapidly than international air passenger demand. Air cargo arrangements need to be as efficient and expeditious as possible, to meet user requirements for air ...

  8. Infants Can Study Air Science.

    Science.gov (United States)

    Ward, Alan

    1983-01-01

    Provided are activities and demonstrations which can be used to teach infants about the nature of air, uses of air, and objects that fly in the air. The latter include airships, hot-air balloons, kites, parachutes, airplanes, and Hovercraft. (JN)

  9. APEX (Air Pollution Exercise) Volume 21: Legal References: Air Pollution Control Regulations.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Office of Manpower Development.

    The Legal References: Air Pollution Control Regulations Manual is the last in a set of 21 manuals (AA 001 009-001 029) used in APEX (Air Pollution Exercise), a computerized college and professional level "real world" game simulation of a community with urban and rural problems, industrial activities, and air pollution difficulties. The manual…

  10. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  11. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  12. Energy and air quality

    International Nuclear Information System (INIS)

    1981-12-01

    This is one of a series of handbooks designed to provide nontechnical readers with a general understanding of the interaction between energy development and environmental media and to provide a rudimentary data base from which estimates of potential future impacts can be made. This handbook describes the air quality impacts of energy development and summarizes the major federal legislation which regulates the potential air quality impacts of energy facilities and can thus influence the locations and timing of energy development. In addition, this report describes and presents the data which can be used as the basis for measurement, and in some cases, prediction of the potential conflicts between energy development and achieving and maintaining clean air. Energy utilization is the largest emission source of man-made air pollutants. Choices in energy resource development and utilization generate varying emissions or discharges into the atmosphere, the emissions are affected by the assimilative character of the atmosphere, and the resultant air pollutant concentrations have biological and aesthetic effects. This handbook describes the interrelationships of energy-related air emissions under various methods of pollution control, the assimilative character of the air medium, and the effects of air pollution. The media book is divided into three major sections: topics of concern relating to the media and energy development, descriptions of how to use available data to quantify and examine energy/environmental impacts, and the data

  13. Air Layer Drag Reduction

    Science.gov (United States)

    Ceccio, Steven; Elbing, Brian; Winkel, Eric; Dowling, David; Perlin, Marc

    2008-11-01

    A set of experiments have been conducted at the US Navy's Large Cavitation Channel to investigate skin-friction drag reduction with the injection of air into a high Reynolds number turbulent boundary layer. Testing was performed on a 12.9 m long flat-plate test model with the surface hydraulically smooth and fully rough at downstream-distance-based Reynolds numbers to 220 million and at speeds to 20 m/s. Local skin-friction, near-wall bulk void fraction, and near-wall bubble imaging were monitored along the length of the model. The instrument suite was used to access the requirements necessary to achieve air layer drag reduction (ALDR). Injection of air over a wide range of air fluxes showed that three drag reduction regimes exist when injecting air; (1) bubble drag reduction that has poor downstream persistence, (2) a transitional regime with a steep rise in drag reduction, and (3) ALDR regime where the drag reduction plateaus at 90% ± 10% over the entire model length with large void fractions in the near-wall region. These investigations revealed several requirements for ALDR including; sufficient volumetric air fluxes that increase approximately with the square of the free-stream speed, slightly higher air fluxes are needed when the surface tension is reduced, higher air fluxes are required for rough surfaces, and the formation of ALDR is sensitive to the inlet condition.

  14. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  15. Low cost solar air heater

    International Nuclear Information System (INIS)

    Gill, R.S.; Singh, Sukhmeet; Singh, Parm Pal

    2012-01-01

    Highlights: ► Single glazed low cost solar air heater is more efficient during summer while double glazed is better in winter. ► For the same initial investment, low cost solar air heaters collect more energy than packed bed solar air heater. ► During off season low cost solar air heater can be stored inside as it is light in weight. - Abstract: Two low cost solar air heaters viz. single glazed and double glazed were designed, fabricated and tested. Thermocole, ultraviolet stabilised plastic sheet, etc. were used for fabrication to reduce the fabrication cost. These were tested simultaneously at no load and with load both in summer and winter seasons along with packed bed solar air heater using iron chips for absorption of radiation. The initial costs of single glazed and double glazed are 22.8% and 26.8% of the initial cost of packed bed solar air heater of the same aperture area. It was found that on a given day at no load, the maximum stagnation temperatures of single glazed and double glazed solar air heater were 43.5 °C and 62.5 °C respectively. The efficiencies of single glazed, double glazed and packed bed solar air heaters corresponding to flow rate of 0.02 m 3 /s-m 2 were 30.29%, 45.05% and 71.68% respectively in winter season. The collector efficiency factor, heat removal factor based on air outlet temperature and air inlet temperature for three solar air heaters were also determined.

  16. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  17. Air-to-air heat pumps in real-life use

    DEFF Research Database (Denmark)

    Gram-Hanssen, Kirsten; Christensen, Toke Haunstrup; Petersen, Poul Erik

    2012-01-01

    This paper deals with individual air-to-air heat pumps in Danish dwellings and summerhouses and the question of to what extent they actually deliver savings of energy consumption. Results show that 20% of the expected reduction of electricity consumption is converted into increased comfort...... in the homes, including extended heating areas, keeping a higher temperature and a longer heating season and using the heat pump for air conditioning. Data include electricity consumption in 185 households before and after installation of heat pumps together with survey results of 480 households. Furthermore...... heating practices. These results have to be taken into account when making long-term energy planning for a sustainable energy system....

  18. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  19. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air......%. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion...... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  20. Mobile Air Monitoring Data Processing Strategies and Effects on Spatial Air Pollution Trends

    Science.gov (United States)

    The collection of real-time air quality measurements while in motion (i.e., mobile monitoring) is currently conducted worldwide to evaluate in situ emissions, local air quality trends, and air pollutant exposure. This measurement strategy pushes the limits of traditional data an...

  1. Exposure of Mammalian Cells to Air-Pollutant Mixtures at the Air-Liquid Interface

    Science.gov (United States)

    It has been widely accepted that exposure of mammalian cells to air-pollutant mixtures at the air-liquid interface is a more realistic approach than exposing cell under submerged conditions. The VITROCELL systems, are commercially available systems for air-liquid interface expo...

  2. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  3. 78 FR 63934 - Approval of Air Quality Implementation Plans; California; El Dorado County Air Quality Management...

    Science.gov (United States)

    2013-10-25

    ...] Approval of Air Quality Implementation Plans; California; El Dorado County Air Quality Management District... California for the El Dorado County Air Quality Management District (EDAQMD) portion of the California SIP... 24, 1987 Federal Register, May 25, 1988, U.S. EPA, Air Quality Management Division, Office of Air...

  4. AIRS/Aqua L2 Near Real Time (NRT) Cloud-Cleared Infrared Radiances (AIRS-only) V006 (AIRS2CCF_NRT) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Atmospheric Infrared Sounder (AIRS) Level 2 Near Real Time (NRT) Cloud-Cleared Infrared Radiances (AIRS-only) product (AIRS2CCF_NRT_006) differs from the routine...

  5. Solar air heaters and their applications

    Science.gov (United States)

    Selcuk, M. K.

    1977-01-01

    The solar air heater appears to be the most logical choice, as far as the ultimate application of heating air to maintain a comfortable environment is concerned. One disadvantage of solar air heaters is the need for handling larger volumes of air than liquids due to the low density of air as a working substance. Another disadvantage is the low thermal capacity of air. In cases where thermal storage is needed, water is superior to air. Design variations of solar air heaters are discussed along with the calculation of the efficiency of a flat plate solar air heater, the performance of various collector types, and the applications of solar air heaters. Attention is given to collectors with nonporous absorber plates, collectors with porous absorbers, the performance of flat plate collectors with finned absorbers, a wire mesh absorber, and an overlapped glass plate air heater.

  6. Air quality and disease

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Climate change is an important determinant of air quality. Climate change is an important determinant of air quality. Poor air quality associated with higher levels of respiratory and cardiovascular disease. Exposure to high levels of ground-level ozone associated with ...

  7. Air Force Leadership Diversity

    Science.gov (United States)

    2017-04-06

    served as a deputy maintenance group commander. Following Air War College he will take command of the 8th Maintenance Group, Kunsan Air Base, Korea ...discrimination in terms of 3 race, religion , sex, etc.: the demographics we have all heard about for years. Air Force Policy Directive (AFPD) 36

  8. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  9. Air Traffic Control Tools Assessment

    Directory of Open Access Journals (Sweden)

    Tomáš Noskievič

    2017-04-01

    Full Text Available Undoubtedly air transport in today’s world wouldn’t be able to exist without any air traffic control service. As the air transport has been coming through major changes and it has been expanding, it is assumed that its volume will be doubled in the next 15 years. Air traffic control uses strictly organised procedures to ensure safe course of air operations. With the skies covered with more airplanes every year, new tools must be introduced to allow the controllers to manage this rising amount of flying aircraft and to keep the air transport safe. This paper provides a comprehensive and organized material, which describes the newest tools and systems used by air traffic control officers. It proposes improvements for further research and development of ATC tools.

  10. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners

    International Nuclear Information System (INIS)

    Riffat, S.B.; Qiu Guoquan

    2004-01-01

    This paper compares the performance of three types of domestic air-conditioners, namely the vapour compression air-conditioner (VCAC), the absorption air-conditioner (AAC) and the thermoelectric air-conditioner (TEAC). The basic cycles of the three types of air-conditioning systems are described and methods to calculate their coefficients of performance are presented. General specification data for each type of air-conditioner are given, and performance characteristics are presented. The comparison shows that although VCACs have the advantages of high COP and low purchase price, use of these systems will be phased out due to their contribution to the greenhouse effect and depletion of the ozone layer. AACs are generally bulky, complex and expensive but operate on thermal energy, so their operational consumption is low. TEACs are environmental friendly, simple and reliable but still very expensive at present. Their low COP is an additional factor limiting their application for domestic cooling. TEACs however, have a large potential market as air-conditioners for small enclosures, such as cars and submarine cabins, where the power consumption would be low, or safety and reliability would be important

  11. Transportation and air quality

    International Nuclear Information System (INIS)

    Roseland, M.

    1992-01-01

    In the greater Vancouver regional district (GVRD), some 80% of the annual production of 600,000 tonnes of air pollutants come from motor vehicles. Three critical air quality issues in the GVRD are discussed: local air pollution, ozone layer depletion, and greenhouse gas emissions, all of which are fundamentally linked to transportation. Overall air quality in the GVRD has been judged acceptable by current federal standards, but ground-level ozone has exceeded maximum tolerable levels at some locations and concentrations of suspended particulates are above maximum acceptable levels. Serious deterioration in air quality has been predicted unless a concerted effort is made to manage air quality on an airshed-wide basis. The GVRD is developing Canada's first Air Management Plan with the goal of halving atmospheric emissions by 2000. GVRD transportation priorities stress public transit, walking, cycling, car pooling, and reducing of travel demand; however, the viability of such strategies depends on decisions made outside the transportation sector. Restricted authority and jurisdiction also hinder GVRD goals; the regional level of government has no authority over highways or transit and only has authority for pollution control in some parts of the Fraser Valley. Airshed quality management, using the Los Angeles example, is seen as a possible direction for future GVRD policymaking in the transportation sector. A single regional planning agency with responsibility for transportation, land use, and air quality management appears as the best option for an integrated approach to solve multiple problems. 19 refs

  12. Dioxin in Danish air

    Energy Technology Data Exchange (ETDEWEB)

    Vikelsoe, J.; Andersen, H.V. [National Environmental Research Inst., Roskilde (Denmark)

    2004-09-15

    To gain more knowledge about dioxin levels, sources and emissions in Denmark, the Danish government year 2001 initiated the Danish Dioxin Monitoring Program. The program is a series of investigations, comprising soil, compost, percolate, bio-ash, incineration of municipal and hazardous waste, deposition, air, lake and fjord sediment as well as cows milk and human milk. The present paper describes the preliminary results for the continued investigation of air. Deposition of dioxin over land or sea is of major importance for the human exposure, which takes place mainly from food intake. The dioxin are emitted mainly to the atmosphere, therefore air measurements are well suited for tracking the transport and fate of dioxin from sources to exposure. Whereas measurements from chimneys has been frequently used to estimate the industrial emission from point sources such as incinerators, air measurements also include emission from diffuse sources such as larger urban or industrial regions, residential quarters, and from evaporation. Furthermore, emission measurements must be done on known sources, whereas air measurements include contribution from unknown source. The major drawbacks of air measurements are the long duration required (years), and the results depends on meteorological conditions, such as temperature, rainfall, wind speed and direction. The purpose of the present study has been to measure dioxins in Danish air, emphasizing - background concentrations and annual variation - difference between urban, rural and residential zones - influence from local sources and long range transport - connection between dioxin in air and deposition.

  13. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Facilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  14. The Air University Pantheon of Air, Space, and Cyberspace Power Thinkers

    Science.gov (United States)

    2009-08-01

    Air Force would not have come as soon as it did. Learn more . . . • James J. Cooke, Billy Mitchell (Boulder, CO: L. Rienner, 2002). • Alfred F...Winter 1974): 18–25. • James Parton, “Air Force Spoken Here”: General Ira Eaker and the Command of the Air (Bethesda, MD: Adler and... Adler , 1986). 99 100 101 Dr. Theodore von Kármán (1881–1963) ♦ Father of supersonic flight ♦ Guggenheim Aeronautics Laboratory professor at the

  15. Our Nation's Air - annual air trends report, USA, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Annual air trends report in the form of an interactive web application. The report features a suite of visualization tools that allow the user to: -Learn about air...

  16. Air Pollution Training Programs.

    Science.gov (United States)

    Public Health Service (DHEW), Rockville, MD.

    This catalog lists the universities, both supported and not supported by the Division of Air Pollution, which offer graduate programs in the field of air pollution. The catalog briefly describes the programs and their entrance requirements, the requirements, qualifications and terms of special fellowships offered by the Division of Air Pollution.…

  17. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  18. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  19. Air quality in Europe - 2011 report

    Energy Technology Data Exchange (ETDEWEB)

    Guerreiro, C.; Larssen, S. (Norsk Inst. for Luftforskning (NILU), Lillestroem (Norway)); Leeuw, F. de (RIVM, Bilthoven (Netherlands)); Foltescu, V. (EEA, Copenhagen (Denmark))

    2011-11-15

    The annual report 'Air quality in Europe' summarises the most recent evaluation of Europe's air quality status. It is mainly based on air quality measurement data that have been made available officially by 32 EEA member countries as well as 6 EEA cooperating countries. The report includes maps and analyses of air quality status over the calendar year 2009. It also analyses air quality trends over the past years. The evaluation of the status and trends of air quality is based on ambient air measurements, in conjunction with reported anthropogenic emissions. The report summarizes the main effects of different air pollutants on human health, the environment and the climate. An overview of policies and measures at European level is also given for each pollutant. This report reviews progress towards meeting the requirements of the two air quality directives in force as well as the air quality guidelines set by the World Health Organization (WHO). The report is produced in support of European and national policy development and implementation in the field of air quality. It also supports air quality management and informs the general public on the current status and trends of air quality in Europe. (Author)

  20. Advanced air distribution

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2011-01-01

    The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...

  1. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  2. Natural Flow Air Cooled Photovoltaics

    Science.gov (United States)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  3. 49 CFR 570.57 - Air brake system and air-over-hydraulic brake subsystem.

    Science.gov (United States)

    2010-10-01

    ... the drain cocks in the service and supply reservoir on the truck or truck-tractor. Note the pressure.... Close the drain cocks, and, with the trailer(s) uncoupled, check air pressure buildup at the... brakes fully applied. (b) Air brake system hoses, tubes and connections. Air system tubes, hoses and...

  4. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  5. Air/Water Purification

    Science.gov (United States)

    1992-01-01

    After 18 years of research into air/water pollution at Stennis Space Center, Dr. B. C. Wolverton formed his own company, Wolverton Environmental Services, Inc., to provide technology and consultation in air and water treatment. Common houseplants are used to absorb potentially harmful materials from bathrooms and kitchens. The plants are fertilized, air is purified, and wastewater is converted to clean water. More than 100 U.S. communities have adopted Wolverton's earlier water hyacinth and artificial marsh applications. Catfish farmers are currently evaluating the artificial marsh technology as a purification system.

  6. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  7. Treatment of reverse osmosis (RO) concentrate by the combined Fe/Cu/air and Fenton process (1stFe/Cu/air-Fenton-2ndFe/Cu/air).

    Science.gov (United States)

    Ren, Yi; Yuan, Yue; Lai, Bo; Zhou, Yuexi; Wang, Juling

    2016-01-25

    To decompose or transform the toxic and refractory reverse osmosis (RO) concentrate and improve the biodegradability, 1stFe/Cu/air-Fenton-2ndFe/Cu/air were developed to treat RO concentrate obtained from an amino acid production plant in northern China. First, their operating conditions were optimized thoroughly. Furthermore, 5 control experiments were setup to confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and synergistic reaction between Fe/Cu/air and Fenton. The results suggest that the developed method could obtain high COD removal (65.1%) and BOD5/COD ratio (0.26) due to the synergistic reaction between Fe/Cu/air and Fenton. Under the optimal conditions, the influent and effluent of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and 5 control experiments were analyzed by using UV, FTIR, EEM and LC, which confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air. Therefore, the developed method in this study is a promising process for treatment of RO concentrate. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  9. Innovative application of air ejector as a pump for continuous air monitors

    International Nuclear Information System (INIS)

    Dhanasekaran, A.; Ajoy, K.C.; Santhanam, R.; Rajagopal, V.; Jose, M.T.

    2016-01-01

    Workplace monitoring, one of the key components of the radiation protection program is generally carried out by means of instruments installed permanently in respective areas or through portable air sampling instruments. Continuous air monitor (CAM) is one such monitor that constantly monitors the radionuclide concentration in air and triggers alarm as and when the air concentration goes above the pre-set levels. Conventional CAM system has a filter head, detector, display unit and a pump as four major parts. Pump may be either rotary vane or a vibrating diaphragm which are electrically driven using motors. Air lift pumps using ejectors are widely used where pump reliability and low maintenance are required, and where corrosive, abrasive, or radioactive fluids are handled. Since ejectors are uncomplicated alternative to vacuum pumps, an attempt was made to use the same as a pump for conventional CAMs. An ejector based sampling set up was made, tested and the results are represented in this paper

  10. Mobile Air Monitoring: Measuring Change in Air Quality in the City of Hamilton, 2005-2010

    Science.gov (United States)

    Adams, Matthew D.; DeLuca, Patrick F.; Corr, Denis; Kanaroglou, Pavlos S.

    2012-01-01

    This paper examines the change in air pollutant concentrations between 2005 and 2010 occurring in the City of Hamilton, Ontario, Canada. After analysis of stationary air pollutant concentration data, we analyze mobile air pollutant concentration data. Air pollutants included in the analysis are CO, PM[subscript 2.5], SO[subscript 2], NO,…

  11. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.

  12. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  13. 78 FR 53270 - Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality...

    Science.gov (United States)

    2013-08-29

    ... Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District... to the Sacramento Metropolitan Air Quality Management District (SMAQMD or District) portion of the..., Sacramento Metropolitan Air Quality Management District, Rule 214 (Federal New Source Review), Rule 203...

  14. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  15. Investigating air quality and air-related complaints in the City of Tshwane, South Africa

    CSIR Research Space (South Africa)

    Wright, C

    2011-12-01

    Full Text Available To determine the impact of implemented air quality interventions beyond ambient air pollution reductions, indicators need to be identified and appropriate health data need to be routinely collected to track air-related health. Presently, the only...

  16. Compressed air noise reductions from using advanced air gun nozzles in research and development environments.

    Science.gov (United States)

    Prieve, Kurt; Rice, Amanda; Raynor, Peter C

    2017-08-01

    The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.

  17. 22 CFR 228.22 - Air transportation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Air transportation. 228.22 Section 228.22... for USAID Financing § 228.22 Air transportation. (a) The eligibility of air transportation is... U.S. flag air carriers for all international air travel and transportation, unless such service is...

  18. Agriculture: Agriculture and Air Quality

    Science.gov (United States)

    Information on air emissions from agricultural practices, types of agricultural burning, air programs that may apply to agriculture, reporting requirements, and links to state and other federal air-quality information.

  19. Filtered air plastic chamber as an experimental facility to prove visible damage of crops due to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Y; Yoda, H; Omichi, S; Shiratori, K

    1975-01-01

    An experimental filtered air chamber was constructed to prove the visible damage of crops due to air pollution. The chamber was provided with another room into which non-filtered ambient air was introduced. The purified air was prepared by filtering ambient air with activated carbon. The average content of air pollutants in the purified air chamber was less than 10 to 20% of the ozone and 20% of the sulfur oxides in the ambient air. However, cultivated vegetables such as tobacco and spinach, which are susceptible to oxidant, showed no visible damage in the filtered air chamber, and showed the same damage in the nonfiltered air chamber as was seen in fields at the same time.

  20. Air void structure and frost resistance

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange

    2014-01-01

    ). This observation is interesting as the parameter of total surface area of air voids normally is not included in air void analysis. The following reason for the finding is suggested: In the air voids conditions are favourable for ice nucleation. When a capillary pore is connected to an air void, ice formation...... on that capillary pores are connected to air voids. The chance that a capillary pore is connected to an air void depends on the total surface area of air voids in the system, not the spacing factor.......This article compiles results from 4 independent laboratory studies. In each study, the same type of concrete is tested at least 10 times, the air void structure being the only variable. For each concrete mix both air void analysis of the hardened concrete and a salt frost scaling test...

  1. Air pollution - health and management

    Energy Technology Data Exchange (ETDEWEB)

    Klug, W; Runca, E; Suess, M J [eds.

    1984-01-01

    The proceedings of a joint workshop of the World Health Organization and the International Institute for Applied Systems Analysis are presented. The workshop was to review the interaction between man's industrial and urban activities and the environment, and the relationship between ambient air quality and human health, and to examine the effectiveness of proper management on the control and abatement of air pollution. The discussion topics included atmospheric processes and respective modelling, air pollution impact on human health, effects of air pollutants on aquatic and terrestrial ecosystems, air pollution episode cycles and management of control. A selected list of 11ASA and WHO/EURO publications related to air pollution is included. Separate abstracts were prepared for 15 papers in this book.

  2. Prototype Pompa Air Portable Tenaga Surya

    OpenAIRE

    Taufik, Mohammad

    2016-01-01

    Makalah ini menyajikan purwarupa pompa air portable tenaga surya. Sistem pompa air portable terdiri atas pompa air, panel surya, solar charge controller, battery, solar frame, tiang, dan box. Sistem dapat dirangkai, sehingga bersifat portable. Pompa air portable ini berguna untuk kolam, irigasi, dan penyediaan air bersih. Hasil optimasi memberikan spesifikasi pompa air berdaya 50 Watt dan tegangan 12 VDC, solar panel berdaya 50 Wp, battery berkapasitas 50 Ah dan tegangan 12 VDC, da...

  3. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  4. Clean air in the Anthropocene.

    Science.gov (United States)

    Lelieveld, Jos

    2017-08-24

    In atmospheric chemistry, interactions between air pollution, the biosphere and human health, often through reaction mixtures from both natural and anthropogenic sources, are of growing interest. Massive pollution emissions in the Anthropocene have transformed atmospheric composition to the extent that biogeochemical cycles, air quality and climate have changed globally and partly profoundly. It is estimated that mortality attributable to outdoor air pollution amounts to 4.33 million individuals per year, associated with 123 million years of life lost. Worldwide, air pollution is the major environmental risk factor to human health, and strict air quality standards have the potential to strongly reduce morbidity and mortality. Preserving clean air should be considered a human right, and is fundamental to many sustainable development goals of the United Nations, such as good health, climate action, sustainable cities, clean energy, and protecting life on land and in the water. It would be appropriate to adopt "clean air" as a sustainable development goal.

  5. Air quality and passenger comfort in an air-conditioned bus micro-environment.

    Science.gov (United States)

    Zhu, Xiaoxuan; Lei, Li; Wang, Xingshen; Zhang, Yinghui

    2018-04-12

    In this study, passenger comfort and the air pollution status of the micro-environmental conditions in an air-conditioned bus were investigated through questionnaires, field measurements, and a numerical simulation. As a subjective analysis, passengers' perceptions of indoor environmental quality and comfort levels were determined from questionnaires. As an objective analysis, a numerical simulation was conducted using a discrete phase model to determine the diffusion and distribution of pollutants, including particulate matter with a diameter air quality and dissatisfactory thermal comfort conditions in Jinan's air-conditioned bus system. To solve these problems, three scenarios (schemes A, B, C) were designed to alter the ventilation parameters. According to the results of an improved simulation of these scenarios, reducing or adding air outputs would shorten the time taken to reach steady-state conditions and weaken the airflow or lower the temperature in the cabin. The airflow pathway was closely related to the layout of the air conditioning. Scheme B lowered the temperature by 0.4 K and reduced the airflow by 0.01 m/s, while scheme C reduced the volume concentration of PM 10 to 150 μg/m 3 . Changing the air supply angle could further improve the airflow and reduce the concentration of PM 10 . With regard to the perception of airflow and thermal comfort, the scheme with an airflow provided by a 60° nozzle was considered better, and the concentration of PM 10 was reduced to 130 μg/m 3 .

  6. 78 FR 10589 - Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality...

    Science.gov (United States)

    2013-02-14

    ... Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District... Sacramento Metropolitan Air Quality Management District (SMAQMD or District) portion of the California State... sources within the areas covered by the plan as necessary to assure that the National Ambient Air Quality...

  7. Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as...

  8. Multifunction Lidar for Air Data and Kinetic Air Hazard Measurement, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ophir proposes to develop a multifunction, low-cost lidar capable of accurately measuring kinetic air hazards, and air data, simultaneously. The innovation is...

  9. 75 FR 65572 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2010-10-26

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY... Ohio Administrative Code (OAC) relating to the consolidation of Ohio's Ambient Air Quality Standards... apply to Ohio's SIP. Incorporating the air quality standards into Ohio's SIP helps assure that...

  10. Study of containment air cooler capacity in steam air environment during accident conditions

    International Nuclear Information System (INIS)

    Kansal, M.; Mohan, N.; Bhawal, R.N.; Bajaj, S.S.

    2002-01-01

    Full text: The air coolers are provided for controlling the temperature in the reactor building during normal operation. These air coolers also serve as the main heat sink for the removal of energy from high enthalpy air-steam mixture expected in reactor building under accident conditions. A subroutine COOLER has been developed to estimate the heat removal rate of the air coolers at high temperature and steam conditions. The subroutine COOLER has been attached with the code PACSR (post accident containment system response) used for containment pressure temperature calculation. The subroutine was validated using design parameters at normal operating condition. A study was done to estimate the heat removal rate for some postulated accident conditions. The study reveals that, under accident conditions, the heat removal rate of air coolers increases several times compared with normal operating conditions

  11. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile terminals mounted...... in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling-mounted diffuser...

  12. Process and apparatus for decontaminating air

    International Nuclear Information System (INIS)

    Reynolds, W.D.

    1993-01-01

    An apparatus for irradiating a contaminated air stream emanating from contaminated sources which contain mixtures of one or more volatile toxic and hazardous organic solvents or petroleum product vapors with ultraviolet wave energy below 200 nm is described comprising: a first means for passing the contaminated air stream via a tube into an enclosed empty air flow duct to allow free flow of said contaminated air stream; a second means for introducing a secondary fresh air stream into an inlet of said first means to dilute and maintain the contaminated air stream at a predetermined concentration level; a means for measuring a flow rate of said contaminated air stream; said air duct containing at least a first and second residence chambers separated by a wall divider; said divider containing at least one opening in which is mounted at least one centrally located ultraviolet wave energy source extending into said air stream to allow said contaminated air stream to pass around and in close contact with said wave energy source, wherein said contaminated air stream is irradiated by said wave energy source; an analyzer means for conducting on-line real time analysis of said diluted contaminated air stream in said first residence chamber, said analyzer means being capable of analyzing any residual contaminated mixtures in an effluent air stream from said second residence chamber; whereby said ultraviolet wave energy source functions to generate oxygen atom free radicals, other free radicals, ions, and ozone to react with the contaminated air strewn to produce unwanted acid gases, and wherein said effluent air stream containing the unwanted acid gases, being passed from said second residence chamber, can be disposed of in any manner known to the art

  13. New calculation method for thermodynamic properties of humid air in humid air turbine cycle – The general model and solutions for saturated humid air

    International Nuclear Information System (INIS)

    Wang, Zidong; Chen, Hanping; Weng, Shilie

    2013-01-01

    The article proposes a new calculation method for thermodynamic properties (i.e. specific enthalpy, specific entropy and specific volume) of humid air in humid air turbine cycle. The research pressure range is from 0.1 MPa to 5 MPa. The fundamental behaviors of dry air and water vapor in saturated humid air are explored in depth. The new model proposes and verifies the relationship between total gas mixture pressure and gas component pressures. This provides a good explanation of the fundamental behaviors of gas components in gas mixture from a new perspective. Another discovery is that the water vapor component pressure of saturated humid air equals P S , always smaller than its partial pressure (f·P S ) which was believed in the past researches. In the new model, “Local Gas Constant” describes the interaction between similar molecules. “Improvement Factor” is proposed for the first time by this article, and it quantitatively describes the magnitude of interaction between dissimilar molecules. They are combined to fully describe the real thermodynamic properties of humid air. The average error of Revised Dalton's Method is within 0.1% compared to experimentally-based data. - Highlights: • Our new model is suitable to calculate thermodynamic properties of humid air in HAT cycle. • Fundamental behaviors of dry air and water vapor in saturated humid air are explored in depth. • Local-Gas-Constant describes existing alone component and Improvement Factor describes interaction between different components. • The new model proposes and verifies the relationship between total gas mixture pressure and component pressures. • It solves saturated humid air thoroughly and deviates from experimental data less than 0.1%

  14. The user's influence on air change

    International Nuclear Information System (INIS)

    Kvisgaard, B.; Collet, P.F.

    1990-01-01

    Of the various parameters deciding the air change in a building, the influence of wind and the stack effect have in particular been focused on. Concurrently, with the increase in quality of buildings and the tightening of existing buildings, the influence of the climatic parameters is reduced, and other parameters gain a greater influence on the air change. One of the parameters having a great influence on the air change in tight buildings are the users. The air change rate is greatly influenced by the users not only in naturally ventilated buildings, but also in mechanically ventilated buildings. On the basis of continuous measurement of the air change in 28 dwellings, the proportion between the total air change (air change in house with occupants) and the basic air change (air change in a sealed house) is discussed. The air change in each of the dwellings has been measured for a period of about one week during occupancy. The measuring principle applied is the method with constant concentration of tracer gas

  15. Impacts of Lowered Urban Air Temperatures on Precursor Emission and Ozone Air Quality.

    Science.gov (United States)

    Taha, Haider; Konopacki, Steven; Akbari, Hashem

    1998-09-01

    Meteorological, photochemical, building-energy, and power plant simulations were performed to assess the possible precursor emission and ozone air quality impacts of decreased air temperatures that could result from implementing the "cool communities" concept in California's South Coast Air Basin (SoCAB). Two pathways are considered. In the direct pathway, a reduction in cooling energy use translates into reduced demand for generation capacity and, thus, reduced precursor emissions from electric utility power plants. In the indirect pathway, reduced air temperatures can slow the atmospheric production of ozone as well as precursor emission from anthropogenic and biogenic sources. The simulations suggest small impacts on emissions following implementation of cool communities in the SoCAB. In summer, for example, there can be reductions of up to 3% in NO x emissions from in-basin power plants. The photochemical simulations suggest that the air quality impacts of these direct emission reductions are small. However, the indirect atmospheric effects of cool communities can be significant. For example, ozone peak concentrations can decrease by up to 11% in summer and population-weighted exceedance exposure to ozone above the California and National Ambient Air Quality Standards can decrease by up to 11 and 17%, respectively. The modeling suggests that if these strategies are combined with others, such as mobile-source emission control, the improvements in ozone air quality can be substantial.

  16. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, AJ; Weusten, BLAM; Timmer, R; Akkermans, LMA; Smout, AJPM

    Background: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  17. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, A. J.; Weusten, B. L. A. M.; Timmer, R.; Akkermans, L. M. A.; Smout, A. J. P. M.

    2005-01-01

    BACKGROUND: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  18. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  19. 77 FR 12524 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY... Indiana State Implementation Plan (SIP) for lead (Pb) under the Clean Air Act (CAA). This submittal incorporates the National Ambient Air Quality Standards (NAAQS) for Pb promulgated by EPA in 2008. DATES...

  20. 75 FR 65594 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2010-10-26

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY... the Ohio Administrative Code (OAC) relating to the consolidation of Ohio's Ambient Air Quality Standards (AAQS) into Ohio's State Implementation Plan (SIP) under the Clean Air Act. On April 8, 2009, and...

  1. 76 FR 72097 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-11-22

    ... Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This rule establishes air quality designations for most areas in the United States for the 2008 lead (Pb) National Ambient Air Quality Standards...

  2. Pure air-plasma bullets propagating inside microcapillaries and in ambient air

    KAUST Repository

    Lacoste, Deanna; Bourdon, Anne; Kuribara, Koichi; Urabe, Keiichiro; Stauss, Sven; Terashima, Kazuo

    2014-01-01

    This paper reports on the characterization of air-plasma bullets in microcapillary tubes and in ambient air, obtained without the use of inert or noble gases. The bullets were produced by nanosecond repetitively pulsed discharges, applied in a dielectric barrier discharge configuration. The anode was a tungsten wire with a diameter of 50 μm, centered in the microcapillary, while the cathode was a silver ring, fixed on the outer surface of the fused silica tube. The effects of the applied voltage and the inner diameter of the microcapillary tube on the plasma behavior were investigated. Inside the tubes, while the topology of the bullets seems to be strongly dependent on the diameter, their velocity is only a function of the amplitude of the applied voltage. In ambient air, the propagation of air bullets with a velocity of about 1.25 ×105 m s-1 is observed.

  3. Pure air-plasma bullets propagating inside microcapillaries and in ambient air

    KAUST Repository

    Lacoste, Deanna

    2014-11-04

    This paper reports on the characterization of air-plasma bullets in microcapillary tubes and in ambient air, obtained without the use of inert or noble gases. The bullets were produced by nanosecond repetitively pulsed discharges, applied in a dielectric barrier discharge configuration. The anode was a tungsten wire with a diameter of 50 μm, centered in the microcapillary, while the cathode was a silver ring, fixed on the outer surface of the fused silica tube. The effects of the applied voltage and the inner diameter of the microcapillary tube on the plasma behavior were investigated. Inside the tubes, while the topology of the bullets seems to be strongly dependent on the diameter, their velocity is only a function of the amplitude of the applied voltage. In ambient air, the propagation of air bullets with a velocity of about 1.25 ×105 m s-1 is observed.

  4. Air pollutant and greenhouse gas emissions - 'Namea-Air' - February 2017

    International Nuclear Information System (INIS)

    Baude, Manuel

    2017-02-01

    For the first time, the SOeS (Monitoring and Statistics Directorate of France's Ministry of the Environment) is publishing air pollutant emissions accounts in the National Accounting Matrix Including Environmental Accounts (NAMEA) format for the years 1990, 1995, 2000, 2005, and 2008 to 2014. Namea-Air is an inventory format breaking down emissions of greenhouse gases (GHG) and air pollutants into 64 branches of economic activity and identifying a 'direct household emissions' category. (author)

  5. Compressed Air Production Using Vehicle Suspension

    OpenAIRE

    Ninad Arun Malpure; Sanket Nandlal Bhansali

    2015-01-01

    Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are co...

  6. Dynamic Performance of a Residential Air-to-Air Heat Pump.

    Science.gov (United States)

    Kelly, George E.; Bean, John

    This publication is a study of the dynamic performance of a 5-ton air-to-air heat pump in a residence in Washington, D.C. The effect of part-load operation on the heat pump's cooling and heating coefficients of performance was determined. Discrepancies between measured performance and manufacturer-supplied performance data were found when the unit…

  7. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  8. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  9. 78 FR 19990 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2013-04-03

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards; Correction AGENCY... approved revisions to Ohio regulations that consolidated air quality standards in a new chapter of rules... State's air quality standards into Ohio Administrative Code (OAC) 3745-25 and modifying an assortment of...

  10. 77 FR 12482 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY... incorporates the National Ambient Air Quality Standards (NAAQS) for Pb promulgated by EPA in 2008. DATES: This... FR 66964) and codified at 40 CFR 50.16, ``National primary and secondary ambient air quality...

  11. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  12. Air Quality Guide for Ozone

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Air Quality Guide for Ozone Ground-level ozone is one of our nation’s most common air pollutants. Use the chart below to help reduce ...

  13. Lean in Air Permitting Guide

    Science.gov (United States)

    The Lean in Air Permitting Guide is designed to help air program managers at public agencies better understand the potential value and results that can be achieved by applying Lean improvement methods to air permitting processes.

  14. A directional passive air sampler for monitoring polycyclic aromatic hydrocarbons (PAHs) in air mass

    International Nuclear Information System (INIS)

    Tao, S.; Liu, Y.N.; Lang, C.; Wang, W.T.; Yuan, H.S.; Zhang, D.Y.; Qiu, W.X.; Liu, J.M.; Liu, Z.G.; Liu, S.Z.; Yi, R.; Ji, M.; Liu, X.X.

    2008-01-01

    A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test. - A novel directional passive air sampler was developed and tested for monitoring PAHs in air masses from different directions

  15. Air Quality Assessment Using Interpolation Technique

    Directory of Open Access Journals (Sweden)

    Awkash Kumar

    2016-07-01

    Full Text Available Air pollution is increasing rapidly in almost all cities around the world due to increase in population. Mumbai city in India is one of the mega cities where air quality is deteriorating at a very rapid rate. Air quality monitoring stations have been installed in the city to regulate air pollution control strategies to reduce the air pollution level. In this paper, air quality assessment has been carried out over the sample region using interpolation techniques. The technique Inverse Distance Weighting (IDW of Geographical Information System (GIS has been used to perform interpolation with the help of concentration data on air quality at three locations of Mumbai for the year 2008. The classification was done for the spatial and temporal variation in air quality levels for Mumbai region. The seasonal and annual variations of air quality levels for SO2, NOx and SPM (Suspended Particulate Matter have been focused in this study. Results show that SPM concentration always exceeded the permissible limit of National Ambient Air Quality Standard. Also, seasonal trends of pollutant SPM was low in monsoon due rain fall. The finding of this study will help to formulate control strategies for rational management of air pollution and can be used for many other regions.

  16. Joakim Helenius: Estonian Air võtku eeskuju airBalticust / Siim Sultson

    Index Scriptorium Estoniae

    Sultson, Siim

    2010-01-01

    Estonian Airi ühe võimaliku nõukogu esimehe Jaokim Heleniuse hinnangul on väikeste lennufirmade, nagu Estonian Air ja airBaltic jaoks päris palju tegutsemisruumi. Estonian Airil tuleb leida oma nišš ja kindel, kuid omanäoline strateegia

  17. The impact of draught related to air velocity, air temperature and workload.

    Science.gov (United States)

    Griefahn, B; Künemund, C; Gehring, U

    2001-08-01

    This experimental study was designed to test the hypotheses that the effects of draught increase with higher air velocity, with lower air temperature, and with lower workload. Thirty healthy young males were exposed to horizontal draught during 55 min while they operated an arm ergometer in a standing posture. Air velocity, air temperature, and workload were varied in 3 steps each, between 11 and 23 degrees C, 0.1 and 0.3 m/s, and 104 to 156 W/m2, respectively. The 27 combinations were distributed over subjects in a fractional factorial 3(3)-design. The participants were clothed for thermal neutrality. Workload was measured at the end of the sessions by respirometry. Draught-induced annoyance was determined every 5 min, separately for 10 body sites. Corresponding skin temperature was also recorded. The hypotheses were verified for the influence of air velocity and air temperature. Regarding workload, local heat production is probably decisive, meaning that draft-induced local annoyance is inversely related to workload in active but independent from workload in non-active body areas. To improve the situation for the workers concerned it is suggested to apply protective gloves that cover an as great area of the forearms as possible and to limit airflows to mean velocities of less than 0.2 m/s (with turbulence intensities of 50%).

  18. Perceived indoor air quality and its relationship to air pollutants in French dwellings.

    Science.gov (United States)

    Langer, S; Ramalho, O; Le Ponner, E; Derbez, M; Kirchner, S; Mandin, C

    2017-11-01

    Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM 10 and PM 2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. 77 FR 53779 - Reports by Air Carriers on Incidents Involving Animals During Air Transport

    Science.gov (United States)

    2012-09-04

    ... Involving Animals During Air Transport AGENCY: Office of the Secretary (OST), Department of Transportation... period of an NPRM on the reporting of incidents involving animals during air transport that was published... animal during air transport. The NPRM proposed to: (1) Expand the reporting requirement to U.S. carriers...

  20. Air Warfare

    Science.gov (United States)

    2002-03-01

    genus as its predecessor of pre-war days. It would, however, be erroneous to conclude from this that the military value of each new development was...the paucity of communications, its conduct, when acting alone, has of necessity to be somewhat stereotyped in nature, and to con- form to a pre...the air, the attack commander, provided his command be equipped with defensive air power, has a rôle to perform which is simple and stereotyped in

  1. Forced Air-Breathing PEMFC Stacks

    Directory of Open Access Journals (Sweden)

    K. S. Dhathathreyan

    2012-01-01

    Full Text Available Air-breathing fuel cells have a great potential as power sources for various electronic devices. They differ from conventional fuel cells in which the cells take up oxygen from ambient air by active or passive methods. The air flow occurs through the channels due to concentration and temperature gradient between the cell and the ambient conditions. However developing a stack is very difficult as the individual cell performance may not be uniform. In order to make such a system more realistic, an open-cathode forced air-breathing stacks were developed by making appropriate channel dimensions for the air flow for uniform performance in a stack. At CFCT-ARCI (Centre for Fuel Cell Technology-ARC International we have developed forced air-breathing fuel cell stacks with varying capacity ranging from 50 watts to 1500 watts. The performance of the stack was analysed based on the air flow, humidity, stability, and so forth, The major advantage of the system is the reduced number of bipolar plates and thereby reduction in volume and weight. However, the thermal management is a challenge due to the non-availability of sufficient air flow to remove the heat from the system during continuous operation. These results will be discussed in this paper.

  2. Air ions and aerosol science

    International Nuclear Information System (INIS)

    Tammet, H.

    1996-01-01

    Collaboration between Gas Discharge and Plasma Physics, Atmospheric Electricity, and Aerosol Science is a factor of success in the research of air ions. The concept of air ion as of any carrier of electrical current through the air is inherent to Atmospheric Electricity under which a considerable statistical information about the air ion mobility spectrum is collected. A new model of air ion size-mobility correlation has been developed proceeding from Aerosol Science and joining the methods of neighboring research fields. The predicted temperature variation of the mobility disagrees with the commonly used Langevin rule for the reduction of air ion mobilities to the standard conditions. Concurrent errors are too big to be neglected in applications. The critical diameter distinguishing cluster ions and charged aerosol particles has been estimated to be 1.4 endash 1.8 nm. copyright 1996 American Institute of Physics

  3. Air-breathing behavior and physiological responses to hypoxia and air exposure in the air-breathing loricariid fish, Pterygoplichthys anisitsi.

    Science.gov (United States)

    da Cruz, André Luis; da Silva, Hugo Ribeiro; Lundstedt, Lícia Maria; Schwantes, Arno Rudi; Moraes, Gilberto; Klein, Wilfried; Fernandes, Marisa Narciso

    2013-04-01

    Hypoxic water and episodic air exposure are potentially life-threatening conditions that fish in tropical regions can face during the dry season. This study investigated the air-breathing behavior, oxygen consumption, and respiratory responses of the air-breathing (AB) armored catfish Pterygoplichthys anisitsi. The hematological parameters and oxygen-binding characteristics of whole blood and stripped hemoglobin and the intermediate metabolism of selected tissue in normoxia, different hypoxic conditions, and after air exposure were also examined. In normoxia, this species exhibited high activity at night and AB behavior (2-5 AB h(-1)). The exposure to acute severe hypoxia elicited the AB behavior (4 AB h(-1)) during the day. Under progressive hypoxia without access to the water surface, the fish were oxyregulators with a critical O2 tension, calculated as the inspired water O2 pressure, as 47 ± 2 mmHg. At water O2 tensions lower than 40 mmHg, the fish exhibited continuous apnea behavior. The blood exhibited high capacity for transporting O2, having a cathodic hemoglobin component with a high Hb-O2 affinity. Under severe hypoxia, the fish used anaerobic metabolism to maintain metabolic rate. Air exposure revealed physiological and biochemical traits similar to those observed under normoxic conditions.

  4. Strategy Guideline: Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  5. Air Risk Information Support Center

    Energy Technology Data Exchange (ETDEWEB)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  6. Air Quality Management Process Cycle

    Science.gov (United States)

    Air quality management are activities a regulatory authority undertakes to protect human health and the environment from the harmful effects of air pollution. The process of managing air quality can be illustrated as a cycle of inter-related elements.

  7. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  8. Compressed Air Production Using Vehicle Suspension

    Directory of Open Access Journals (Sweden)

    Ninad Arun Malpure

    2015-08-01

    Full Text Available Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are collecting air in the cylinder and store this energy into the tank by simply driving the vehicle. This method is non-conventional as no fuel input is required and is least polluting.

  9. A Long-Life Lithium-Air Battery in Ambient Air with a Polymer Electrolyte Containing a Redox Mediator.

    Science.gov (United States)

    Guo, Ziyang; Li, Chao; Liu, Jingyuan; Wang, Yonggang; Xia, Yongyao

    2017-06-19

    Lithium-air batteries when operated in ambient air generally exhibit poor reversibility and cyclability, because of the Li passivation and Li 2 O 2 /LiOH/Li 2 CO 3 accumulation in the air electrode. Herein, we present a Li-air battery supported by a polymer electrolyte containing 0.05 m LiI, in which the polymer electrolyte efficiently alleviates the Li passivation induced by attacking air. Furthermore, it is demonstrated that I - /I 2 conversion in polymer electrolyte acts as a redox mediator that facilitates electrochemical decomposition of the discharge products during recharge process. As a result, the Li-air battery can be stably cycled 400 times in ambient air (relative humidity of 15 %), which is much better than previous reports. The achievement offers a hope to develop the Li-air battery that can be operated in ambient air. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  11. Infrequent air contamination with Acinetobacter baumannii of air surrounding known colonized or infected patients.

    Science.gov (United States)

    Rock, Clare; Harris, Anthony D; Johnson, J Kristie; Bischoff, Werner E; Thom, Kerri A

    2015-07-01

    Using a validated air sampling method we found Acinetobacter baumannii in the air surrounding only 1 of 12 patients known to be colonized or infected with A. baumannii. Patients' closed-circuit ventilator status, frequent air exchanges in patient rooms, and short sampling time may have contributed to this low burden.

  12. Air quality compliance improvements through operational management of air resources (OMAR)

    International Nuclear Information System (INIS)

    Goddard, W.B.; Goddard, C.B.

    1990-01-01

    Geothermal well fields and power plants require operational and emergency atmospheric venting. Venting activities are monitored for compliance with regulations which limit air pollutant emissions and Ambient Air Quality Standards (AAQS). Continuous compliance monitoring data which includes hydrogen sulfide (H2S) levels and meteorological conditions is only available moths after being compiled. In this paper an automated computerized system called OMAR is described in the following which checks data and allows users access to real-time and near real-time data reports. The data can then be used for managing necessary venting or other real-time data needs. The OMAR system hardware and software is descried and is in use at The Geysers and at the Coso KGRA geothermal developments in California. The system has been designed to assist developers, engineers, scientists, and the local air districts in their goal of maintaining ambient air quality within Federal, State and Local standards

  13. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  14. Ozone - Current Air Quality Index

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Current AQI Forecast AQI Loop More Maps AQI: Good (0 - 50) ... resources for Hawaii residents and visitors more announcements Air Quality Basics Air Quality Index | Ozone | Particle Pollution | Smoke ...

  15. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    Science.gov (United States)

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  16. Air compliance through pollution prevention at Air Force Materiel Command facilities.

    Energy Technology Data Exchange (ETDEWEB)

    Kolpa, R.; Ryckman, S.J. Jr.; Smith, A.E.

    1999-03-19

    Options for air compliance through pollution prevention (P2) have been identified at 14 facilities of the US Air Force Materiel Command, ranging from depots with significant light industrial activity to laboratories. Previous P2 efforts concentrated on reducing hazardous and solid wastes, with any reduction in air impacts generally being a collateral benefit. This work focused on reducing air emissions and air compliance vulnerabilities. P2 options were identified in three stages. First, potentially applicable P2 options were identified from Internet and published information. Attention was given to identifying the types of sources to which an option could be applied, the option's state of development, and constraints that could limit its application. Traditional P2 options involving technology or equipment changes and material substitution were considered. In addition, newer approaches based on administrative ''controls'' were considered. These included inserting P2 into operating permits in exchange for administrative relief, privatization, derating boilers, and reducing an installation's potential to emit and compliance vulnerability by separating sources not under the Air Force's ''common control.'' Next, criteria and toxic emissions inventories by source category were prepared from inventory data supplied by facilities. The major problems at this stage were differences in the levels of detail provided by facilities and in the categories used by different installations. Emitting categories were matched to P2 option categories to identify candidate options. Candidates were screened to account for local regulations and technical information about sources in the inventories. When possible, emission reductions were estimated to help facility personnel prioritize options. Some options identified are being actively pursued by facilities to determine their site-specific feasibility. Although much work has been

  17. Evaluation of AirGIS: a GIS-based air pollution and human exposure modelling system

    DEFF Research Database (Denmark)

    Ketzel, Matthias; Berkowicz, Ruwim; Hvidberg, Martin

    2011-01-01

    This study describes in brief the latest extensions of the Danish Geographic Information System (GIS)-based air pollution and human exposure modelling system (AirGIS), which has been developed in Denmark since 2001 and gives results of an evaluation with measured air pollution data. The system...... shows, in general, a good performance for both long-term averages (annual and monthly averages), short-term averages (hourly and daily) as well as when reproducing spatial variation in air pollution concentrations. Some shortcomings and future perspectives of the system are discussed too....

  18. The Assessment of Air Pollutant Concentrations and Air Quality Index in Shiraz during 2011-2013

    Directory of Open Access Journals (Sweden)

    Monireh Majlesi Nasr

    2016-06-01

    Full Text Available Background: Exposure to air pollutants can cause many problems, including the health effects in humans and animals. The aim of this study was to assay the air quality in the Shiraz city during 2011-2013. Methods: In this descriptive-analytical study, the air pollutant data during the study period were taken from Air Quality Co. for two main stations i.e. Darvazeh Kazeroun and Imam Hossein and then were analysed to determine air quality index. Results: The maximum (0.018 ppm and minimum (0.015 ppm annual concentration of SO2 were determined in 2011 and 2013, respectively. The maximum NO2 concentration was measured in summer 2011 with a value of 0.025 ppm. Regarding ozone, the highest average concentration was measured in the summer season of 2013 with the concentration of 0.068 ppm. In terms of air quality, the worst situation was experienced in 2011, which about 31 percent of the days have been marked as unhealthy, but during the last years of the study, the air quality get better. Conclusion: In general, the results of the study showed that SO2 concentration has been decreased during recent years due to strengthen of air pollution regulation but NO2 concentration was increased because the number of gas fuel automobile was also increased. With regard to air quality, it has an improving trend during the study period.

  19. Impacts of Changes of Indoor Air Pressure and Air Exchange Rate in Vapor Intrusion Scenarios.

    Science.gov (United States)

    Shen, Rui; Suuberg, Eric M

    2016-02-01

    There has, in recent years, been increasing interest in understanding the transport processes of relevance in vapor intrusion of volatile organic compounds (VOCs) into buildings on contaminated sites. These studies have included fate and transport modeling. Most such models have simplified the prediction of indoor air contaminant vapor concentrations by employing a steady state assumption, which often results in difficulties in reconciling these results with field measurements. This paper focuses on two major factors that may be subject to significant transients in vapor intrusion situations, including the indoor air pressure and the air exchange rate in the subject building. A three-dimensional finite element model was employed with consideration of daily and seasonal variations in these factors. From the results, the variations of indoor air pressure and air exchange rate are seen to contribute to significant variations in indoor air contaminant vapor concentrations. Depending upon the assumptions regarding the variations in these parameters, the results are only sometimes consistent with the reports of several orders of magnitude in indoor air concentration variations from field studies. The results point to the need to examine more carefully the interplay of these factors in order to quantitatively understand the variations in potential indoor air exposures.

  20. Air quality indices : a review

    International Nuclear Information System (INIS)

    Hewings, J.

    2001-10-01

    Pollution Probe presents some background information that will help in the development of a national Air Quality Index (AQI) in Canada. This report examines the issues that should be addressed in revising the national Index of the Quality of Air (IQUA) or creating a new national Air Quality Index. The IQUA was devised in 1976 and provides Canadians with real-time information on the state of community air quality by including major pollutants and their synergies. It is currently being used for air quality management plans and air quality alert systems. At the same time that the IQUA was devised, the United States Environmental Protection Agency (US EPA) produced a parallel air quality index known as the Pollution Standard Index (PSI) which incorporated 5 criteria pollutants (particulate matter, sulphur dioxide, carbon monoxide, nitrogen oxide and ground level ozone) for which national health-based standards were devised. In 1999, the US EPA renamed their index the Air Quality Index (AQI) and made revisions to the primary health-based national ambient air quality standards for ground-level ozone and particulate matter. Separate values for PM2.5 and PM10 were incorporated and mandatory reporting was required for metropolitan areas with populations of 350,000 or more. Similarly, the IQUA has undergone major developments that affect the validity of the index, including: rejection by the Working Group on Air Quality Objectives and Guidelines of the previous maximum desirable and maximum acceptable air quality criteria, recognition that standards for many of the contaminants are outdated, developing more sensitive instrumentation for real-time monitoring of contaminants. This report also describes the use of the national short term Air Quality Index by provincial, territorial and local authorities in Canada. Pollution Probe recommends setting up a mechanism to review and revise IQUA on a regular basis that would incorporate governments, the medical profession, special

  1. Air-Inflated Fabric Structures

    National Research Council Canada - National Science Library

    Cavallaro, Paul V; Sadegh, Ali M

    2006-01-01

    .... Examples include air ships, weather balloons, inflatable antennas and radomes, temporary shelters, pneumatic muscles and actuators, inflatable boats, temporary bridging, and energy absorbers such as automotive air bags...

  2. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  3. Air to air fixed plate enthalpy heat exchanger, performance variation and energy analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nasif, Mohammad Shakir [Universiti Teknologi Petronas, Bandar Seri Iskandar (Malaysia); Alwaked, Rafat [Prince Mohammad Bin Fahd University, Al Khobar (Saudi Arabia); Behnia, Masud [University of Sydney, Sydney (Australia); Morrison, Graham [The University of New South Wales, Sydney (Australia)

    2013-11-15

    The thermal performance of a Z shape enthalpy heat exchanger utilising 70 gsm Kraft paper as the heat and moisture transfer surface has been investigated. Effects of different inlet air humidity ratio conditions on the heat exchanger effectiveness and on the energy recovered by the heat exchanger have been the main focus of this investigation. A typical air conditioning cooling coil which incorporates an enthalpy heat exchanger has been modelled for tropical climate. Under test conditions, results have shown that latent effectiveness and the moisture resistance coefficient have strong dependency on the inlet air humidity ratio. Moreover, the latent effectiveness has been found to be strongly dependent on the moisture resistance coefficient rather than the convective mass transfer coefficient. Finally, annual energy analysis for Singapore weather conditions have also shown that energy recovered under variable inlet air conditions is 15% less than that recovered under constant inlet air conditions for the same heat exchanger.

  4. Air Pollution in Museum Buildings

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, Morten

    2017-01-01

    This paper reviews the main air pollutants relevant for preservation of cultural heritage objects. Air pollutants may originate from outdoor or indoor sources. Indoor sources include the emission of corrosive vapors from construction materials used for museum display settings. Air pollution may...

  5. Human preference for air movement

    DEFF Research Database (Denmark)

    Toftum, Jørn; Melikov, Arsen Krikor; Tynel, A.

    2002-01-01

    Human preference for air movement was studied at slightly cool, neutral, and slightly warm overall thermal sensations and at temperatures ranging from 18 deg.C to 28 deg.C. Air movement preference depended on both thermal sensation and temperature, but large inter-individual differences existed...... between subjects. Preference for less air movement was linearly correlated with draught discomfort, but the percentage of subjects who felt draught was lower than the percentage who preferred less air movement....

  6. Radioactive material air transportation

    International Nuclear Information System (INIS)

    Pader y Terry, Claudio Cosme

    2002-01-01

    As function of the high aggregated value, safety regulations and the useful life time, the air transportation has been used more regularly because is fast, reliable, and by giving great security to the cargo. Based on the International Atomic Energy Agency (IAEA), the IATA (International Air Transportation Association) has reproduced in his dangerous goods manual (Dangerous Goods Regulations - DGR IATA), the regulation for the radioactive material air transportation. Those documents support this presentation

  7. Improving and monitoring air quality.

    Science.gov (United States)

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  8. Civil Air Patrol Proposed Agreements With the Air Force Are Intended to Address Identified Problems

    National Research Council Canada - National Science Library

    2000-01-01

    The Air Force and Civil Air Patrol relationship is usually cooperative. The Air Force includes the Patrol in its internal budget process to determine what the Patrol needs and how much money will be available to support the Patrol...

  9. α,β-Unsaturated aldehyde pollutant acrolein suppresses cardiomyocyte contractile function: Role of TRPV1 and oxidative stress.

    Science.gov (United States)

    Wu, Zhenbiao; He, Emily Y; Scott, Glenda I; Ren, Jun

    2015-01-01

    Air pollution is associated with an increased prevalence of heart disease and is known to trigger a proinflammatory response via stimulation of transient receptor potential vanilloid cation channels (TRPV1, also known as the capsaicin receptor). This study was designed to examine the effect of acrolein, an essential α,β-unsaturated aldehyde pollutant, on myocardial contractile function and the underlying mechanism involved with a focus on TRPV1 and oxidative stress. Cardiomyocyte mechanical and intracellular Ca(2+) properties were evaluated using an IonOptix MyoCam® system including peak shortening (PS), maximal velocity of shortening/relengthening (± dL/dt), time-to-PS (TPS), time-to-90% relengthening (TR90 ), fura-2 fluorescence intensity (FFI) and intracellular Ca(2+) decay. Changes in apoptosis and TRPV1 were evaluated using Western blot analysis. The degree of oxidative stress was assessed using the ratio between reduced and oxidized glutathione. Results obtained revealed that exposure of cardiomyocytes to acrolein acutely compromised contractile and intracellular Ca(2+) properties including depressed PS, ± dL/dt and ΔFFI, as well as prolonged TR90 and intracellular Ca(2+) decay. In addition, acrolein exposure upregulated TRPV1 associated with an increase in both apoptosis and oxidative stress. However, the acrolein-induced cardiomyocyte contractile and intracellular Ca(2+) anomalies, as well as apoptosis (as evidenced by Bcl-2, Bax, FasL, Caspase-3 and -8), were negated by the reactive oxygen species (ROS) scavenger glutathione or the TRPV1 antagonist capsazepine. Collectively these data suggest that the α,β-unsaturated aldehyde pollutant acrolein may play a role in the pathogenesis and sequelae of air pollution-induced heart disease via a TRPV1- and oxidative stress-dependent mechanism. © 2013 Wiley Periodicals, Inc.

  10. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  11. Air distribution system with the discharge action in the working cavity of downhole air hammer drills

    Science.gov (United States)

    Timonin, VV; Alekseev, SE; Kokoulin, DI; Kubanychbek, B.

    2018-03-01

    It is proposed to carry out pre-mine methane drainage using underground degassing holes made by downhole air hammer drills. The features of downhole air drills are described. The downhole air drill layout with the simple-shape striking part is presented with its pluses and minuses. The researchers point at available options to eliminate the shortcomings. The improved layout of the downhole air hammer drill is suggested. The paper ends with the test data on the prototype air hammer drill, its characteristics and trial drilling results.

  12. Air brake-dynamometer accurately measures torque

    Science.gov (United States)

    1965-01-01

    Air brake-dynamometer assembly combines the principles of the air turbine and the air pump to apply braking torque. The assembly absorbs and measures power outputs of rotating machinery over a wide range of shaft speeds. It can also be used as an air turbine.

  13. Air traffic control activity increases attention capacity in air traffic controllers.

    Science.gov (United States)

    Ribas, Valdenilson Ribeiro; Martins, Hugo André de Lima; Amorim, Gutemberg Guerra; Ribas, Renata de Melo Guerra; de Almeida, Cláudia Ângela Vilela; Ribas, Valéria Ribeiro; de Vasconcelos, Carlos Augusto Carvalho; Lima, Murilo Duarte Costa; Sougey, Everton Botelho; de Castro, Raul Manhães

    2010-01-01

    Air traffic controllers simultaneously develop complex and multiple tasks in the course of their activities. In this context, concern is raised over the high level of attention needed by these professionals which can ultimately be affected by stress and fatigue. The objective of this study was to assess attention level in air traffic controllers (ATCo). 45 flight protection professionals were evaluated, comprising 30 ATCo, subdivided into ATCo with ten or more years in the profession (ATCo≥10, n=15) and ATCo with less than ten years in the profession (ATCo air traffic control activity after ten years may be associated with a high level of attention.

  14. AIR for Javascript Developers Pocket Guide

    CERN Document Server

    Chambers, Mike; Hoyt, Kevin; Georgita, Dragos

    2009-01-01

    This book is the official guide to Adobe ® AIR[TM], written by members of the AIR team. With Adobe AIR, web developers can use technologies like HTML and JavaScript to build and deploy web applications to the desktop. Packed with examples, this book explains how AIR works and features recipes for performing common runtime tasks. Part of the Adobe Developer Library, this concise pocket guide explains: What Adobe AIR is, and the problems this runtime aims to solveHow to set up your development environmentThe HTML and JavaScript environments within AIRHow to create your first AIR application

  15. Compressed Air/Vacuum Transportation Techniques

    Science.gov (United States)

    Guha, Shyamal

    2011-03-01

    General theory of compressed air/vacuum transportation will be presented. In this transportation, a vehicle (such as an automobile or a rail car) is powered either by compressed air or by air at near vacuum pressure. Four version of such transportation is feasible. In all versions, a ``c-shaped'' plastic or ceramic pipe lies buried a few inches under the ground surface. This pipe carries compressed air or air at near vacuum pressure. In type I transportation, a vehicle draws compressed air (or vacuum) from this buried pipe. Using turbine or reciprocating air cylinder, mechanical power is generated from compressed air (or from vacuum). This mechanical power transferred to the wheels of an automobile (or a rail car) drives the vehicle. In type II-IV transportation techniques, a horizontal force is generated inside the plastic (or ceramic) pipe. A set of vertical and horizontal steel bars is used to transmit this force to the automobile on the road (or to a rail car on rail track). The proposed transportation system has following merits: virtually accident free; highly energy efficient; pollution free and it will not contribute to carbon dioxide emission. Some developmental work on this transportation will be needed before it can be used by the traveling public. The entire transportation system could be computer controlled.

  16. Air quality management in Botswana

    Directory of Open Access Journals (Sweden)

    Modupe O. Akinola

    2017-06-01

    Full Text Available This paper examines air pollution situation and the history of air quality management in Botswana. The current air quality management in Botswana is still largely underpinned by the Atmospheric Pollution Prevention Act of 1971, supplemented by the more recently enacted legislations such as the Environmental Impact Assessment (EIA Act of 2010 and the Ambient Air Quality - Limits for Common Pollutants of 2012 published by the Botswana Bureau of Standards. Though commendable efforts have been made toward legislating against air and other forms of pollution, these have not yielded expected results in view of the prevailing levels of air pollutants like sulphur dioxide and fine particulate matters in the country’s atmospheric environment. Legislation as a sole measure may not be effective in tackling this challenge. Rather, government should also address some root-causes of the problem by making policies and programmes that will reduce unemployment and increase the earning capacity of citizenry. This will, among other things, effectively check poverty-induced biomass burning in the country. The paper looks at some other challenges of air pollution management and suggestions are made to tackle the identified problems.

  17. AIR RADIOACTIVITY MONITOR

    Science.gov (United States)

    Bradshaw, R.L.; Thomas, J.W.

    1961-04-11

    The monitor is designed to minimize undesirable background buildup. It consists of an elongated column containing peripheral electrodes in a central portion of the column, and conduits directing an axial flow of radioactively contaminated air through the center of the column and pure air through the annular portion of the column about the electrodes. (AEC)

  18. Air Pollution Primer.

    Science.gov (United States)

    National Tuberculosis and Respiratory Disease Association, New York, NY.

    As the dangers of polluted air to the health and welfare of all individuals became increasingly evident and as the complexity of the causes made responsibility for solutions even more difficult to fix, the National Tuberculosis and Respiratory Disease Association felt obligated to give greater emphasis to its clean air program. To this end they…

  19. 77 FR 73320 - Approval of Air Quality Implementation Plans; California; South Coast Air Quality Management...

    Science.gov (United States)

    2012-12-10

    ... Quality Implementation Plans; California; South Coast Air Quality Management District; Prevention of... Implementation Plan (SIP) revision for the South Coast Air Quality Management District (SCAQMD or District... in a August 15, 2012 letter from the South Coast Air Quality Management District regarding specific...

  20. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  1. Bad traffic, bad air

    OpenAIRE

    Duca, Edward

    2012-01-01

    Air pollution is one of Malta’s greatest concerns. Transportation is the principal source with over 300,000 vehicles belching out smoke, which damages our environment and health. Emissions from vehicles need to be monitored and controlled, and the information used to improve the current system and ensure an acceptable air quality. By using the pollution data set, Nicolette Formosa (supervised by Dr Kenneth Scerri) mapped the air pollution levels and major sources around Malta. http://www....

  2. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  3. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  4. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  5. Air Quality and Climate Change

    International Nuclear Information System (INIS)

    Colette, A.; Rouil, L.; Bessagnet, B.; Schucht, S.; Szopa, S.; Vautard, R.; Menut, L.

    2013-01-01

    Climate change and air quality are closely related: through the policy measures implemented to mitigate these major environmental threats but also through the geophysical processes that drive them. We designed, developed and implemented a comprehensive regional air quality and climate modeling System to investigate future air quality in Europe taking into account the combined pressure of future climate change and long range transport. Using the prospective scenarios of the last generation of pathways for both climate change (emissions of well mixed greenhouse gases) and air pollutants, we can provide a quantitative view into the possible future air quality in Europe. We find that ozone pollution will decrease substantially under the most stringent scenario but the efforts of the air quality legislation will be adversely compensated by the penalty of global warming and long range transport for the business as usual scenario. For particulate matter, the projected reduction of emissions efficiently reduces exposure levels. (authors)

  6. Control of the outlet air temperature in an air handling unit

    DEFF Research Database (Denmark)

    Brath, P.; Rasmussen, Henrik; Hägglund, T.

    1998-01-01

    This paper discuss modeling and control of the inlet temperature in an Air Handling Unit, AHU. The model is based on step response experiments made at a full scale test plant. We use gain scheduling to lower the correlation of the air flow with the process dynamic which simplify the control task...

  7. 32 CFR 989.30 - Air quality.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1. ...

  8. Monitoring the levels of toxic air pollutants in the ambient air of ...

    African Journals Online (AJOL)

    user

    The ambient air quality in Freetown, Sierra Leone was investigated for the first time for toxic air pollutants. ..... 215 Switzerland), in a water bath at temperature of 55°C and pressure of ..... scraps. Furthermore, the prolonged use of generators.

  9. Methane flux across the air-water interface - Air velocity effects

    Science.gov (United States)

    Sebacher, D. I.; Harriss, R. C.; Bartlett, K. B.

    1983-01-01

    Methane loss to the atmosphere from flooded wetlands is influenced by the degree of supersaturation and wind stress at the water surface. Measurements in freshwater ponds in the St. Marks Wildlife Refuge, Florida, demonstrated that for the combined variability of CH4 concentrations in surface water and air velocity over the water surface, CH4 flux varied from 0.01 to 1.22 g/sq m/day. The liquid exchange coefficient for a two-layer model of the gas-liquid interface was calculated as 1.7 cm/h for CH4 at air velocity of zero and as 1.1 + 1.2 v to the 1.96th power cm/h for air velocities from 1.4 to 3.5 m/s and water temperatures of 20 C.

  10. SpaceX Dragon Air Circulation System

    Science.gov (United States)

    Hernandez, Brenda; Piatrovich, Siarhei; Prina, Mauro

    2011-01-01

    The Dragon capsule is a reusable vehicle being developed by Space Exploration Technologies (SpaceX) that will provide commercial cargo transportation to the International Space Station (ISS). Dragon is designed to be a habitable module while it is berthed to ISS. As such, the Dragon Environmental Control System (ECS) consists of pressure control and pressure equalization, air sampling, fire detection, illumination, and an air circulation system. The air circulation system prevents pockets of stagnant air in Dragon that can be hazardous to the ISS crew. In addition, through the inter-module duct, the air circulation system provides fresh air from ISS into Dragon. To utilize the maximum volume of Dragon for cargo packaging, the Dragon ECS air circulation system is designed around cargo rack optimization. At the same time, the air circulation system is designed to meet the National Aeronautics Space Administration (NASA) inter-module and intra-module ventilation requirements and acoustic requirements. A flight like configuration of the Dragon capsule including the air circulation system was recently assembled for testing to assess the design for inter-module and intra-module ventilation and acoustics. The testing included the Dragon capsule, and flight configuration in the pressure section with cargo racks, lockers, all of the air circulation components, and acoustic treatment. The air circulation test was also used to verify the Computational Fluid Dynamics (CFD) model of the Dragon capsule. The CFD model included the same Dragon internal geometry that was assembled for the test. This paper will describe the Dragon air circulation system design which has been verified by testing the system and with CFD analysis.

  11. Air quality indicators

    International Nuclear Information System (INIS)

    Clench-Aas, Jocelyn; Guerreiro, Cristina; Bartonova, Alena

    1999-06-01

    This report proposes and describes in detail several air quality indicators that may be used to describe population exposure. The suggested indicators account for temporal and spatial patterns of pollution and movements of individuals between different micro-environments. The Air Quality Indicator /AQI) should represent both the spatial and temporal aspects of pollution exposure that may have important effects on health. Two indicators are needed, the Population Air Quality Indicator and the Individual Air Quality Indicator. Mean concentrations, 98th percentile and maximum values are the traditional indicators for estimating exposure. the temporal variability of PM-10 and NO 2 , however, is here described by means of: 1) The rate of change of pollution as the difference between two consecutive hourly values and of 2) episodes, described in terms of number, duration and winter episode period, maximum concentration in the episode and integrated episode exposure (episode AOT50/100). The spatial variation of AQIs can be described in several ways, e.g.: 1) Concentrations in neighbouring grid squares can be compared as an indication of spatial variation and 2) point estimates can be compared to grid values for a description of variation within a grid. Both methods are presented here. A test of the representativity of static point estimates for pollution exposure is to compare them to an estimate of air pollution exposure accounting for movements between different locations, obtained using diaries. The ultimate aim of AQIs is to describe the population exposure to ambient pollution. This is done by estimating the number of people exposed using different characteristics of AQIs. The data used to describe these indicators originates from dispersion modelling of short-term air pollution concentrations in Oslo. Two series of data are used. One represents hour-for hour concentrations in the 1 km 2 grid system covering the city of Oslo, winter 1994/95, calculated by the grid

  12. Pigeons home faster through polluted air

    OpenAIRE

    Zhongqiu Li; Franck Courchamp; Daniel T. Blumstein

    2016-01-01

    Air pollution, especially haze pollution, is creating health issues for both humans and other animals. However, remarkably little is known about how animals behaviourally respond to air pollution. We used multiple linear regression to analyse 415 pigeon races in the North China Plain, an area with considerable air pollution, and found that while the proportion of pigeons successfully homed was not influenced by air pollution, pigeons homed faster when the air was especially polluted. Our resu...

  13. Letter to the Editor: Applications Air Q Model on Estimate Health Effects Exposure to Air Pollutants

    Directory of Open Access Journals (Sweden)

    Gholamreza Goudarzi

    2016-02-01

    Full Text Available Epidemiologic studies in worldwide have measured increases in mortality and morbidity associated with air pollution (1-3. Quantifying the effects of air pollution on the human health in urban area causes an increasingly critical component in policy discussion (4-6. Air Q model was proved to be a valid and reliable tool to predicts health effects related to criteria  pollutants (particulate matter (PM, ozone (O3, nitrogen dioxide (NO2, sulfur dioxide (SO2, and carbon monoxide (CO, determinate  the  potential short term effects of air pollution  and allows the examination of various scenarios in which emission rates of pollutants are varied (7,8. Air Q software provided by the WHO European Centre for Environment and Health (ECEH (9. Air Q model is based on cohort studies and used to estimates of both attributable average reductions in life-span and numbers of mortality and morbidity associated with exposure to air pollution (10,11. Applications

  14. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  15. Assessment of air quality benefits from national air pollution control policies in China. Part II: Evaluation of air quality predictions and air quality benefits assessment

    Science.gov (United States)

    Wang, Litao; Jang, Carey; Zhang, Yang; Wang, Kai; Zhang, Qiang; Streets, David; Fu, Joshua; Lei, Yu; Schreifels, Jeremy; He, Kebin; Hao, Jiming; Lam, Yun-Fat; Lin, Jerry; Meskhidze, Nicholas; Voorhees, Scott; Evarts, Dale; Phillips, Sharon

    2010-09-01

    Following the meteorological evaluation in Part I, this Part II paper presents the statistical evaluation of air quality predictions by the U.S. Environmental Protection Agency (U.S. EPA)'s Community Multi-Scale Air Quality (Models-3/CMAQ) model for the four simulated months in the base year 2005. The surface predictions were evaluated using the Air Pollution Index (API) data published by the China Ministry of Environmental Protection (MEP) for 31 capital cities and daily fine particulate matter (PM 2.5, particles with aerodiameter less than or equal to 2.5 μm) observations of an individual site in Tsinghua University (THU). To overcome the shortage in surface observations, satellite data are used to assess the column predictions including tropospheric nitrogen dioxide (NO 2) column abundance and aerosol optical depth (AOD). The result shows that CMAQ gives reasonably good predictions for the air quality. The air quality improvement that would result from the targeted sulfur dioxide (SO 2) and nitrogen oxides (NO x) emission controls in China were assessed for the objective year 2010. The results show that the emission controls can lead to significant air quality benefits. SO 2 concentrations in highly polluted areas of East China in 2010 are estimated to be decreased by 30-60% compared to the levels in the 2010 Business-As-Usual (BAU) case. The annual PM 2.5 can also decline by 3-15 μg m -3 (4-25%) due to the lower SO 2 and sulfate concentrations. If similar controls are implemented for NO x emissions, NO x concentrations are estimated to decrease by 30-60% as compared with the 2010 BAU scenario. The annual mean PM 2.5 concentrations will also decline by 2-14 μg m -3 (3-12%). In addition, the number of ozone (O 3) non-attainment areas in the northern China is projected to be much lower, with the maximum 1-h average O 3 concentrations in the summer reduced by 8-30 ppb.

  16. Canada's Clean Air Act

    International Nuclear Information System (INIS)

    2006-01-01

    This paper provided an outline of Canada's Clean Air Act and examined some of the regulatory changes that will occur as a result of its implementation. The Act is being introduced to strengthen the legislative basis for taking action on reducing air pollution and GHGs, and will allow the government to regulate both indoor and outdoor air pollutants and GHGs. The Act will require the Ministers of the Environment and Health to establish national air quality objectives, as well as to monitor and report on their attainment. The Canadian Environmental Protection Act will be amended to enable the government to regulate the blending of fuels and their components. The Motor Vehicle Fuel Consumption Standards Act will also be amended to enhance the government's authority to regulate vehicle fuel efficiency. The Energy Efficiency Act will also be expanded to allow the government to set energy efficiency standards and labelling requirements for a wider range of consumer and commercial products. The Act will commit to short, medium and long-term industrial air pollution targets. Regulations will be proposed for emissions from industry; on-road and off-road vehicles and engines; and consumer and commercial products. It was concluded that the Government of Canada will continue to consult with provinces, territories, industries and Canadians to set and reach targets for the reduction of both indoor and outdoor air pollutants and GHG emissions. 6 figs

  17. Advance planning for air pollution control

    Energy Technology Data Exchange (ETDEWEB)

    Brewer, G L

    1972-11-01

    An air quality management program for nitric acid plants emitting pollutants which include nitrogen oxides is proposed. The program consists of the following five phases: an inventory of the handling equipment within the plant, including the identification of potential emission sources in terms of process material balances; source testing (if required); ambient air quality measurements; emission control analysis; and the development of a complete air management plan which includes a balance between air exhausted from buildups and processes and air supplied in a controlled economical manner. Typical NOx air pollution problems associated with nitric acid plants are reviewed along with various approaches to control and by-product recovery.

  18. Air effect on polycarbonate radiolysis

    International Nuclear Information System (INIS)

    Terence, Mauro C.; Araujo, Elmo S.; Guedes, Selma M.L.

    1995-01-01

    The formation and decay of radicals in the radiolysis of new type of polycarbonate (G scission = 0,73) was investigated by electron spin resonance spectroscopy in the presence and absence of air at room temperature. The air does not interfere in the formation of radicals because they are formed as consequence of direct interaction of radiation. But the air interferes in their decays. During the irradiation the air reacts with all isopropyl radicals and with 2/3 of phenoxy + phenyl radicals. (author). 5 refs., 3 figs

  19. Air pollution: impact and prevention.

    Science.gov (United States)

    Sierra-Vargas, Martha Patricia; Teran, Luis M

    2012-10-01

    Air pollution is becoming a major health problem that affects millions of people worldwide. In support of this observation, the World Health Organization estimates that every year, 2.4 million people die because of the effects of air pollution on health. Mitigation strategies such as changes in diesel engine technology could result in fewer premature mortalities, as suggested by the US Environmental Protection Agency. This review: (i) discusses the impact of air pollution on respiratory disease; (ii) provides evidence that reducing air pollution may have a positive impact on the prevention of disease; and (iii) demonstrates the impact concerted polices may have on population health when governments take actions to reduce air pollution. © 2012 The Authors. Respirology © 2012 Asian Pacific Society of Respirology.

  20. 29 CFR 1917.154 - Compressed air.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  1. AIRS/Aqua Level 3 Pentad quantization in physical units (AIRS-only) V005

    Data.gov (United States)

    National Aeronautics and Space Administration — AIRS/Aqua Level 3 pentad quantization product in physical units (AIRS Only). The quantization products (QP) are distributional summaries derived from the Level-2...

  2. Air pollution forecast in cities by an air pollution index highly correlated with meteorological variables

    International Nuclear Information System (INIS)

    Cogliani, E.

    2001-01-01

    There are many different air pollution indexes which represent the global urban air pollution situation. The daily index studied here is also highly correlated with meteorological variables and this index is capable of identifying those variables that significantly affect the air pollution. The index is connected with attention levels of NO 2 , CO and O 3 concentrations. The attention levels are fixed by a law proposed by the Italian Ministries of Health and Environment. The relation of that index with some meteorological variables is analysed by the linear multiple partial correlation statistical method. Florence, Milan and Vicence were selected to show the correlation among the air pollution index and the daily thermic excursion, the previous day's air pollution index and the wind speed. During the January-March period the correlation coefficient reaches 0.85 at Milan. The deterministic methods of forecasting air pollution concentrations show very high evaluation errors and are applied on limited areas around the observation stations, as opposed to the whole urban areas. The global air pollution, instead of the concentrations at specific observation stations, allows the evaluation of the level of the sanitary risk regarding the whole urban population. (Author)

  3. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  4. Heated air humidification versus cold air nebulization in newly tracheostomized patients.

    Science.gov (United States)

    Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich

    2017-12-01

    After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  5. Experimental analysis of fuzzy controlled energy efficient demand controlled ventilation economizer cycle variable air volume air conditioning system

    Directory of Open Access Journals (Sweden)

    Rajagopalan Parameshwaran

    2008-01-01

    Full Text Available In the quest for energy conservative building design, there is now a great opportunity for a flexible and sophisticated air conditioning system capable of addressing better thermal comfort, indoor air quality, and energy efficiency, that are strongly desired. The variable refrigerant volume air conditioning system provides considerable energy savings, cost effectiveness and reduced space requirements. Applications of intelligent control like fuzzy logic controller, especially adapted to variable air volume air conditioning systems, have drawn more interest in recent years than classical control systems. An experimental analysis was performed to investigate the inherent operational characteristics of the combined variable refrigerant volume and variable air volume air conditioning systems under fixed ventilation, demand controlled ventilation, and combined demand controlled ventilation and economizer cycle techniques for two seasonal conditions. The test results of the variable refrigerant volume and variable air volume air conditioning system for each techniques are presented. The test results infer that the system controlled by fuzzy logic methodology and operated under the CO2 based mechanical ventilation scheme, effectively yields 37% and 56% per day of average energy-saving in summer and winter conditions, respectively. Based on the experimental results, the fuzzy based combined system can be considered to be an alternative energy efficient air conditioning scheme, having significant energy-saving potential compared to the conventional constant air volume air conditioning system.

  6. Air conditioner with three stages of indirect regeneration

    International Nuclear Information System (INIS)

    Worthington, M.N.

    1987-01-01

    An air conditioner is described comprising: a cabinet defining an internal evaporation chamber and having an air inlet and an air outlet; a heat exchanger mounted in the cabinet and defining an air movement path between the air inlet and the air outlet; means for supplying air to be cooled to the air inlet of the cabinet of movement through the air movement path of the heat exchanger in a heat exchanger relationship; air diversion means for continuously diverting some of the air emerging from the air outlet of the cabinet; and means in the evaporation chamber of the cabinet for recirculating spraying water into the chiller tube of the heat exchanger for interacting with the diverted air moving therethrough to evaporatively cool the heat exchanger

  7. Air quality monitoring at Seoul, Korea as a part of East-Asian air surveillance network

    International Nuclear Information System (INIS)

    Hashimoto, Y.; Sekine, Y.; Kim, H.K.; Otoshi, T.

    1989-01-01

    Global scale air pollution study is a recent trend due to a perception that air pollution is changing climate and other essential earth's conditions that could seriously affect our lives. One of the important tasks which can contribute to protect our natural environment must be to know about the present and changing air quality. For this purpose, a regional air monitoring plan was designed by a research group and has proceeded to set up stations in the eastern Asia including Japan, Korea and China to get continuous data which can contribute to world wide data base of air quality. This project was initiated at Seoul, Korea in April, 1986 by the method of National Air Surveillance Network, Japan. Airborne particles were collected by so-called Hi-vol and Lo-vol, and their components were analyzed by neutron activation analysis and others. The results of Seoul sampling as a first step of this network plan are presented

  8. Air Pollution, Causes and Cures.

    Science.gov (United States)

    Manufacturing Chemists Association, Washington, DC.

    This commentary on sources of air pollution and air purification treatments is accompanied by graphic illustrations. Sources of carbon monoxide, sulfur oxides, nitrogen oxides, and hydrocarbons found in the air are discussed. Methods of removing these pollutants at their source are presented with cut-away diagrams of the facilities and technical…

  9. Air barrier systems: Construction applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrault, J.C

    1989-01-01

    An examination is presented of how ordinary building materials can be used in an innovative manner to design, detail, and construct effective air barrier systems for common types of walls. For residential construction, the air drywall approach uses the interior gypsum board as the main component of the wall air barrier system. Joints between the gypsum board and adjacent materials or assemblies are sealed by gaskets. In commercial construction, two different techniques are employed for using gypsum board as air barrier material: the accessible drywall and non-accessible drywall approaches. The former is similar to the air drywall approach except that high performance sealants are used instead of gaskets. In the latter approach, exterior drywall sheathing is the main component of the air barrier system; joints between boards are taped and joints between boards and other components are sealed using elastomeric membrane strips. For various types of commercial and institutional buildings, metal air barrier systems are widely used and include pre-engineered curtain walls or sheet metal walls. Masonry wall systems are regarded as still the most durable, fireproof, and soundproof wall type available but an effective air barrier system has typically been difficult to implement. Factory-made elastomeric membranes offer the potential to provide airtightness to masonry walls. These membranes are applied on the entire masonry wall surface and are used to make airtight connections with other building components. Two types of product are available: thermofusible and peel-and-stick membranes. 5 figs.

  10. Performance assessment and transient optimization of air precooling in multi-stage solid desiccant air conditioning systems

    International Nuclear Information System (INIS)

    Gadalla, Mohamed; Saghafifar, Mohammad

    2016-01-01

    Highlights: • Studying three two-stage solid desiccant cooling systems using Maisotsenko cooler. • Proposing precooling to improve two-stage desiccant systems’ COP for humid climates. • Performing transient analysis for a two-stage solid desiccant cooler in UAE. • Optimizing daily performance of a two-stage solid desiccant cooler for UAE. - Abstract: Renewable energy is one of the most promising solutions to both energy and global warming crisis. Energy consumption can be minimized considerably by utilizing solar energy in air conditioning systems operation. One of the popular solar air conditioning technologies is desiccant air conditioning. Nonetheless, conventional desiccant air conditioning systems have a relatively low coefficient of performance (COP). In consequence, two-stage desiccant air-conditioning systems are proposed to improve desiccant air conditioning systems’ COP. Moreover, a recently commercialized cooling method named Maisotsenko cooling cycle which is capable of cooling air near to its dew point temperature is considered to be integrated within the proposed multi-stage desiccant cooling systems. In this paper, three new two-stage desiccant air conditioning systems incorporating Maisotsenko cooling cycle are proposed and investigated in details for hot and humid climates such as UAE. Furthermore, air precooling is considered to improve two stage desiccant air conditioning systems’ COP. Moreover, full transient analysis and optimization are carried out in UAE within June–October. The proposed system can minimize the required solar heating during noon time as the ambient air dry bulb temperature rises. Average COP of the system during electricity load peak hours (10:00–14:00) for all five considered and combined months is 1.77. Average rate of heat input required to operate the system and average building cooling load are determined to be 100.3 kW and 46.2 kW, respectively. Therefore, system average COP is computed to be 0.46.

  11. 30 CFR 75.321 - Air quality.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away flammable...

  12. Air quality in Europe - 2012 report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-15

    This report presents an overview and analysis of the status and trends of air quality in Europe based on concentration measurements in ambient air and data on anthropogenic emissions and trends from 2001 - when mandatory monitoring of ambient air concentrations of selected pollutants first produced reliable air quality information - to 2010. (Author)

  13. Allegheny County Air Quality

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Air quality data from Allegheny County Health Department monitors throughout the county. Air quality monitored data must be verified by qualified individuals before...

  14. Controlling Indoor Air Pollution from Moxibustion

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2016-06-01

    Full Text Available Indoor air quality (IAQ control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs of traditional Chinese medicine (TCM may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2, carbon monoxide (CO, formaldehyde (HCHO, total volatile organic compounds (TVOCs, airborne particulate matter with a diameter of ≤10 µm (PM10 and ≤2.5 µm (PM2.5 during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  15. Sumatera Air Asia Training Center (Arsitektur Metafora)

    OpenAIRE

    Susanto, William

    2015-01-01

    Sumatera Air Asia Training Center as Air Asia training facility’s construction have a propose to train the Air Asia air craft crew who will be the employee of the Air Asia Airlines.Beside the main function;training facility for the Air Asia Crew; the other airline’s crew can be train by a cooperation with Air Asia.The aircraft crew that can be train in this facility is pilot initial, pilot type-rating, pilot recurrent, ATPL, Flight attendant initial and recurrent..This facility ha...

  16. Air pollution

    International Nuclear Information System (INIS)

    Feugier, A.

    1996-01-01

    The air pollution results from the combustion of petroleum products, natural gas, coal, wastes and transports. Some compounds are considered as particularly pollutants: the carbon monoxide, the nitrogen oxides, the tropospheric ozone and the sulfur dioxides. Their environmental and biological effects are described. The present political guide lines concerns the combustion plants, the ozone, the wastes incineration and the vehicles emissions. The aim is at some future date to control the air quality, to reduce the volatile organic compounds emissions and to limit the sulfur rate of some petroleum products. (O.L.)

  17. Antibubbles and fine cylindrical sheets of air

    KAUST Repository

    Beilharz, D.

    2015-08-14

    Drops impacting at low velocities onto a pool surface can stretch out thin hemispherical sheets of air between the drop and the pool. These air sheets can remain intact until they reach submicron thicknesses, at which point they rupture to form a myriad of microbubbles. By impacting a higher-viscosity drop onto a lower-viscosity pool, we have explored new geometries of such air films. In this way we are able to maintain stable air layers which can wrap around the entire drop to form repeatable antibubbles, i.e. spherical air layers bounded by inner and outer liquid masses. Furthermore, for the most viscous drops they enter the pool trailing a viscous thread reaching all the way to the pinch-off nozzle. The air sheet can also wrap around this thread and remain stable over an extended period of time to form a cylindrical air sheet. We study the parameter regime where these structures appear and their subsequent breakup. The stability of these thin cylindrical air sheets is inconsistent with inviscid stability theory, suggesting stabilization by lubrication forces within the submicron air layer. We use interferometry to measure the air-layer thickness versus depth along the cylindrical air sheet and around the drop. The air film is thickest above the equator of the drop, but thinner below the drop and up along the air cylinder. Based on microbubble volumes, the thickness of the cylindrical air layer becomes less than 100 nm before it ruptures.

  18. Antibubbles and fine cylindrical sheets of air

    KAUST Repository

    Beilharz, D.; Guyon, A.; Li, E.  Q.; Thoraval, M.-J.; Thoroddsen, Sigurdur T

    2015-01-01

    Drops impacting at low velocities onto a pool surface can stretch out thin hemispherical sheets of air between the drop and the pool. These air sheets can remain intact until they reach submicron thicknesses, at which point they rupture to form a myriad of microbubbles. By impacting a higher-viscosity drop onto a lower-viscosity pool, we have explored new geometries of such air films. In this way we are able to maintain stable air layers which can wrap around the entire drop to form repeatable antibubbles, i.e. spherical air layers bounded by inner and outer liquid masses. Furthermore, for the most viscous drops they enter the pool trailing a viscous thread reaching all the way to the pinch-off nozzle. The air sheet can also wrap around this thread and remain stable over an extended period of time to form a cylindrical air sheet. We study the parameter regime where these structures appear and their subsequent breakup. The stability of these thin cylindrical air sheets is inconsistent with inviscid stability theory, suggesting stabilization by lubrication forces within the submicron air layer. We use interferometry to measure the air-layer thickness versus depth along the cylindrical air sheet and around the drop. The air film is thickest above the equator of the drop, but thinner below the drop and up along the air cylinder. Based on microbubble volumes, the thickness of the cylindrical air layer becomes less than 100 nm before it ruptures.

  19. Improvement to Air2Air Technology to Reduce Fresh-Water Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Ken Mortensen

    2011-12-31

    This program was undertaken to enhance the manufacturability, constructability, and cost of the Air2Air{TM} Water Conservation and Plume Abatement Cooling Tower, giving a validated cost basis and capability. Air2Air{TM} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10% - 25% annually, depending on the cooling tower location (climate). This program improved the efficiency and cost of the Air2Air{TM} Water Conservation Cooling Tower capability, and led to the first commercial sale of the product, as described.

  20. Monitoring of total suspended air particulate in the ambient air of ...

    African Journals Online (AJOL)

    Monitoring of total suspended air particulate in the ambient air of welding, car painting and. V. C. IKAMAISE, I. B. OBIOH, I. E. OFOZIE, F. A. AKEREDOLU. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/gjpas.v7i4.16316.

  1. Air Pollution Forecasts: An Overview.

    Science.gov (United States)

    Bai, Lu; Wang, Jianzhou; Ma, Xuejiao; Lu, Haiyan

    2018-04-17

    Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies.

  2. Air Pollution Forecasts: An Overview

    Directory of Open Access Journals (Sweden)

    Lu Bai

    2018-04-01

    Full Text Available Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies.

  3. Air Pollution Forecasts: An Overview

    Science.gov (United States)

    Bai, Lu; Wang, Jianzhou; Lu, Haiyan

    2018-01-01

    Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies. PMID:29673227

  4. Swimming in air-breathing fishes.

    Science.gov (United States)

    Lefevre, S; Domenici, P; McKenzie, D J

    2014-03-01

    Fishes with bimodal respiration differ in the extent of their reliance on air breathing to support aerobic metabolism, which is reflected in their lifestyles and ecologies. Many freshwater species undertake seasonal and reproductive migrations that presumably involve sustained aerobic exercise. In the six species studied to date, aerobic exercise in swim flumes stimulated air-breathing behaviour, and there is evidence that surfacing frequency and oxygen uptake from air show an exponential increase with increasing swimming speed. In some species, this was associated with an increase in the proportion of aerobic metabolism met by aerial respiration, while in others the proportion remained relatively constant. The ecological significance of anaerobic swimming activities, such as sprinting and fast-start manoeuvres during predator-prey interactions, has been little studied in air-breathing fishes. Some species practise air breathing during recovery itself, while others prefer to increase aquatic respiration, possibly to promote branchial ion exchange to restore acid-base balance, and to remain quiescent and avoid being visible to predators. Overall, the diversity of air-breathing fishes is reflected in their swimming physiology as well, and further research is needed to increase the understanding of the differences and the mechanisms through which air breathing is controlled and used during exercise. © 2014 The Fisheries Society of the British Isles.

  5. Can a photocatalytic air purifier be used to improve the perceived air quality indoors?

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Wargocki, Pawel

    2010-01-01

    The effect of a photocatalytic air purifier on perceived air quality(PAQ) was examined in rooms polluted by typical sources of indoor pollution.The rooms were ventilated at three different outdoor air supply rates. The air quality was assessed by a sensory panel when the purifier was in operation...... as well as when it was off. Operation of the purifier significantly improved PAQ in the rooms polluted by building materials (used carpet, old linoleum, and old chip-board), and a used ventilation filter as well as a mixture of building materials, used ventilation filter and cathode-ray tube computer...... monitors. The effect cor-responded to approximately doubling the outdoor air supply rate. Operation of the purifier significantly worsened the PAQ in rooms with human bioeffluents, probably due to incomplete oxidation of alcohols which are one of the main pollutants emitted by humans. Present results show...

  6. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  7. Lead (Pb) Air Pollution

    Science.gov (United States)

    ... Regional Offices Labs and Research Centers Lead (Pb) Air Pollution Contact Us Share As a result of EPA's ... and protect aquatic and terrestrial ecosystems. Lead (Pb) Air Pollution Basic Information How does lead get in the ...

  8. Atmospheric Chemistry and Air Pollution

    Directory of Open Access Journals (Sweden)

    Jeffrey S. Gaffney

    2003-01-01

    Full Text Available Atmospheric chemistry is an important discipline for understanding air pollution and its impacts. This mini-review gives a brief history of air pollution and presents an overview of some of the basic photochemistry involved in the production of ozone and other oxidants in the atmosphere. Urban air quality issues are reviewed with a specific focus on ozone and other oxidants, primary and secondary aerosols, alternative fuels, and the potential for chlorine releases to amplify oxidant chemistry in industrial areas. Regional air pollution issues such as acid rain, long-range transport of aerosols and visibility loss, and the connections of aerosols to ozone and peroxyacetyl nitrate chemistry are examined. Finally, the potential impacts of air pollutants on the global-scale radiative balances of gases and aerosols are discussed briefly.

  9. Air pollution in the Slovak Republic, 2001

    International Nuclear Information System (INIS)

    Mitosinkova, M.; Kozakovic, L.; Zavodsky, D.; Sajtakova, E.; Mareckova, K.; Pukancikova, K.

    2003-01-01

    A report on air quality and contribution of individual sources on its pollution in the Slovak Republic in 2001 is presented. This report consists of two parts: (1) Ambient air and (2) Emission. Ambient air part is divided into the following chapters: Regional air pollution and quality of precipitation; Local air pollution; Atmospheric ozone. Emission part is divided into the following chapters: Emission and air pollution source inventory, Greenhouse gas emissions

  10. Olefin metathesis in air

    Directory of Open Access Journals (Sweden)

    Lorenzo Piola

    2015-10-01

    Full Text Available Since the discovery and now widespread use of olefin metathesis, the evolution of metathesis catalysts towards air stability has become an area of significant interest. In this fascinating area of study, beginning with early systems making use of high oxidation state early transition metal centers that required strict exclusion of water and air, advances have been made to render catalysts more stable and yet more functional group tolerant. This review summarizes the major developments concerning catalytic systems directed towards water and air tolerance.

  11. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys

    2013-01-01

    The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV...... with air filter and 29 °C with DPV without filter. During the experiments the subjects simulated office work and answered on computerized questionnaires. At warm environment PAQ and air freshness significantly improved when DPV was used. Eye dryness increased significantly with time but was not influenced...... by air temperature and filtering. At 29 °C the facially applied air movement from DPV increased the eye dryness. The SBS symptoms increased with time and were higher (not significantly) at the warm conditions. Air movement did not have profound impact on the SBS symptoms, while filtering had only at 23...

  12. Restoran Buenos Aires = Restaurant Buenos Aires

    Index Scriptorium Estoniae

    2008-01-01

    Restorani Buenos Aires (Narva mnt. 5, Tallinn) sisekujundusest. Sisearhitektid: Janno Roos ja Andres Labi (Ruumilabor OÜ). Laudu eraldavad 400 vardasse aetud puukuuli. Sisearhitektidest, nende tähtsamad tööd. I-III korruse plaan, 12 värv. vaadet, fotod sisearhitektidest

  13. Thermodynamic diagrams for high temperature plasmas of air, air-carbon, carbon-hydrogen mixtures, and argon

    CERN Document Server

    Kroepelin, H; Hoffmann, K-U

    2013-01-01

    Thermodynamic Diagrams for High Temperature Plasmas of Air, Air-Carbon, Carbon-Hydrogen Mixtures, and Argon provides information relating to the properties of equilibrium gas plasmas formed from hydrocarbons, from air without argon, from pure argon, and from mixtures of air and carbon at various compositions, temperatures and pressures. The data are presented in graphical rather than tabular form to provide a clearer picture of the plasma processes investigated. This book is composed of four chapters, and begins with the introduction to the characteristics of plasmas, with emphasis on their th

  14. The effect of a photocatalytic air purifier on indoor air quality quantified using different measuring methods

    DEFF Research Database (Denmark)

    Kolarik, Barbara; Wargocki, Pawel; Skorek-Osikowska, A.

    2010-01-01

    The effect on indoor air quality of an air purifier based on photocatalytic oxidation (PCO) was determined by different measuring techniques: sensory assessments of air quality made by human subjects, Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) and chromatographic methods (Gas......, additional measurements were made with no pollution sources present in the office. All conditions were tested with the photocatalytic air purifier turned on and off. The results show that operation of the air purifier in the presence of pollutants emitted by building materials and furniture improves indoor...... Chromatography/Mass Spectrometry and High-Pressure Liquid Chromatography with UV detection). The experiment was conducted in a simulated office, ventilated with 0.6 h(-1), 2.5 h(-1) and 6 h(-1), in the presence of additional pollution sources (carpet, chipboard and linoleum). At the lowest air change rate...

  15. Energy Conservation In Compressed Air Systems

    International Nuclear Information System (INIS)

    Yusuf, I.Y.; Dewu, B.B.M.

    2004-01-01

    Compressed air is an essential utility that accounts for a substantial part of the electricity consumption (bill) in most industrial plants. Although the general saying Air is free of charge is not true for compressed air, the utility's cost is not accorded the rightful importance due to its by most industries. The paper will show that the cost of 1 unit of energy in the form of compressed air is at least 5 times the cost electricity (energy input) required to produce it. The paper will also provide energy conservation tips in compressed air systems

  16. Numerical Modelling and Analysis of Hydrostatic Thrust Air Bearings for High Loading Capacities and Low Air Consumption

    Science.gov (United States)

    Yu, Yunluo; Pu, Guang; Jiang, Kyle

    2017-12-01

    The paper presents a numerical simulation study on hydrostatic thrust air bearings to assess the load capacity, compressed air consumptions, and the dynamic response. Finite Difference Method (FDM) and Finite Volume Method (FVM) are combined to solve the non-linear Reynolds equation to find the pressure distribution of the air bearing gas film and the total loading capacity of the bearing. The influence of design parameters on air film gap characteristics, including the air film thickness, supplied pressure, depth of the groove and external load, are investigated based on the proposed FDM model. The simulation results show that the thrust air bearings with a groove have a higher load capacity and air consumption than without a groove, and the load capacity and air consumption both increase with the depth of the groove. Bearings without the groove are better damped than those with the grooves, and the stability of thrust bearing decreases when the groove depth increases. The stability of the thrust bearings is also affected by their loading.

  17. Health and efficiency in trimix versus air breathing in compressed air workers.

    Science.gov (United States)

    Van Rees Vellinga, T P; Verhoeven, A C; Van Dijk, F J H; Sterk, W

    2006-01-01

    The Western Scheldt Tunneling Project in the Netherlands provided a unique opportunity to evaluate the effects of trimix usage on the health of compressed air workers and the efficiency of the project. Data analysis addressed 318 exposures to compressed air at 3.9-4.4 bar gauge and 52 exposures to trimix (25% oxygen, 25% helium, and 50% nitrogen) at 4.6-4.8 bar gauge. Results revealed three incidents of decompression sickness all of which involved the use of compressed air. During exposure to compressed air, the effects of nitrogen narcosis were manifested in operational errors and increased fatigue among the workers. When using trimix, less effort was required for breathing, and mandatory decompression times for stays of a specific duration and maximum depth were considerably shorter. We conclude that it might be rational--for both medical and operational reasons--to use breathing gases with lower nitrogen fractions (e.g., trimix) for deep-caisson work at pressures exceeding 3 bar gauge, although definitive studies are needed.

  18. Models for Comparing Air-Only and Sea/Air Transportation of Wartime Deployment Cargo

    National Research Council Canada - National Science Library

    Theres, Michael

    1998-01-01

    ...) to an overseas Port of Debarkation (POD). This thesis evaluates a proposal to load air-transportable cargo aboard vessels at CONUS seaports and to ship that cargo to an appropriately located sea-air-interface (SAI...

  19. Designing and testing the optimum design of automotive air-to-air thermoelectric air conditioner (TEAC) system

    International Nuclear Information System (INIS)

    Attar, Alaa; Lee, HoSung

    2016-01-01

    Highlights: • The optimum design of automotive thermoelectric AC system is proposed. • It is optimized by combining the thermal isolation and the dimensionless methods. • An experiment is conducted to validate the analytical design. - Abstract: The current project is discussing the optimization of counter flow air-to-air thermoelectric air conditioners (TEAC) system. Previous work showed an analytical model with experimental validation of a unit cell of TEAC system. However, the focus of this work is to simulate the optimum design of a whole TEAC system from given inlet parameters (i.e., hot and cold air mass flow rates and ambient temperatures). The analytical model was built by combining an optimal design method with dimensional analysis, which was recently developed, and the thermal isolation method in order to optimize the thermoelectric parameters (i.e., electrical current supplied and the number of thermocouples or the geometric factor, simultaneously). Moreover, based on the designed model, an experiment was conducted in order to study the accuracy of the analytical model. Even though the analytical model was built based on the thermoelectric ideal equations, it shows a good agreement with the experiment. This agreement was mainly a result of the use of the thermoelectric effective material properties which are obtained from the measured maximum thermoelectric module parameters. Since the experiment validate the analytical model, this model provides uncomplicated method to study the optimum design at given inputs.

  20. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  1. Advanced air detritiation dryer

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The isotopic exchange principle has proved effective in increasing air detritiation factors of atmospheric dryers. A CFFTP/AECL Chalk River program has demonstrated detritiation factors of 100,000 in trials. The technology is designed for application on regenerating atmospheric dryers using molecular sieve desiccant beds, used in rooms likely to encounter airborne tritium contamination. Dryer design concepts for dryers at JET (Joint European Torus, England) and ITER have been prepared by Alan Dombra of AECL, using the isotopic exchange technology. The isotopic exchange method works by passing tritiated air over a detritiated desiccant bed. Airborne tritium atoms are exchanged in the bed for ordinary hydrogen atoms from the bed's residual moisture loading. Tritium remains on the bed until it is discharged in a regeneration cycle. During regeneration, the desiccant bed is first heated with hot, dry air to drive off collected tritiated moisture. Airborne tritium removed from the air is collected as a tritiated water distillate and stored for later processing. During the second part of the regeneration cycle, the desiccant bed is washed with clean moist air to elute remaining traces of tritium and to refresh the bed to ready it for another tritium absorption period

  2. Air-To-Air Visual Target Acquisition Pilot Interview Survey.

    Science.gov (United States)

    1979-01-01

    8217top’ 5 p~lots in air-tu-air visual target acqui- sition in your squadron," would/could you do it? yes no Comment : 2. Is the term "acquisition" as...meaningful as "spotting" and "seeing" in 1he con- text of visually detecting a "bogey" or another aircraft? yes no Comment : 3. Would/could you rank all...squadron pilots on the basis of their visual target acquisition capability? yes no Comment : 4. Is there a minimum number of observations requi.red for

  3. Unit for air decontamination; Unidad para descontaminacion de aire

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-02-15

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  4. Combination of air-source heat pumps with liquid desiccant dehumidification of air

    International Nuclear Information System (INIS)

    Zhang Li; Hihara, Eiji; Saikawa, Michiyuki

    2012-01-01

    Highlights: ► We propose a frost-free air-source heat pump system with integrated desiccant. ► The system can provide heating load continuously and humidify room. ► The coefficient of performance of the system is 2.6 at T a = −7 °C and RH = 80%. ► The heating load of solution is 3–4 times larger than cooling load of solution. - Abstract: This paper proposes a frost-free air source heat pump system with integrated liquid desiccant dehumidification, in which frosting can be retarded by dehumidifying air before entering an outdoor heat exchanger. And the water removed from the air is used to humidify a room. Simulation is carried out at a dry-bulb temperature of −7 to 5.5 °C and a relative humidity of 80% depending on the frosting conditions. The results show that the coefficient of performance (COP) is in the range of 2.6–2.9, which is 30–40% higher than that of heat pump heating integrated with an electric heater humidifying system. And it is found that the optimum value of the concentration of lithium chloride aqueous solution is 37% for the frost-free operation mode. Experiments are conducted for liquid desiccant system under low air temperature and high relative humidity conditions. Experimental results show that the dew point of the dehumidified air is decreased by 8 °C and the humidity ratio of the humidified air is kept at 8.1 g kg −1 , which ensures the frost-free operation of the heat pump evaporator and the comfortable level of room humidity simultaneously. The heating load of solution is 3–4.5 times larger than cooling load of solution, which agrees with the assumption given at the part of the simulation. Furthermore, the deviations between the calculated COP LHRU and the experimental results are within 33%.

  5. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  6. Assessment of indoor air quality in comparison using air conditioning and fan system in printing premise

    OpenAIRE

    Ramlan Nazirah; Nurhalimatul Husna Ahmad Siti; Aminuddin Eeydzah; Abdul Hamid Hazrul; Khalijah Yaman Siti; Halid Abdullah Abd

    2017-01-01

    Printers contribute to various emissions consist with chemical contaminants. High concentration of the particulate matter can cause serious health problems. This study focuses on the indoor air quality in printing premise unit in Universiti Tun Hussein Onn, Malaysia. Field testing involving air sampling methods were taken from 900 hours to 1600 hours, for every 30 minutes using physical measurement which is Multi-Channel Air Quality Monitor (YESAIR), E-Sampler and Ozone Meter. Air sampling wa...

  7. Historical Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Historical Ambient Air Quality Data Inventory contains measured and estimated data on ambient air pollution for use in assessing air quality, assisting in...

  8. Air Quality in Lanzhou, a Major Industrial City in China: Characteristics of Air Pollution and Review of Existing Evidence from Air Pollution and Health Studies

    Science.gov (United States)

    Zhang, Yaqun; Li, Min; Bravo, Mercedes A.; Jin, Lan; Nori-Sarma, Amruta; Xu, Yanwen; Guan, Donghong; Wang, Chengyuan; Chen, Mingxia; Wang, Xiao; Tao, Wei; Qiu, Weitao; Zhang, Yawei

    2015-01-01

    Air pollution contributes substantially to global health burdens; however, less is known about pollution patterns in China and whether they differ from those elsewhere. We evaluated temporal and spatial heterogeneity of air pollution in Lanzhou, an urban Chinese city (April 2009–December 2012), and conducted a systematic review of literature on air pollution and health in Lanzhou. Average levels were 141.5, 42.3, and 47.2 µg/m3 for particulate matter with an aerodynamic diameter ≤10 µm (PM10), NO2, and SO2, respectively. Findings suggest some seasonality, particularly for SO2, with higher concentrations during colder months relative to warmer months, although a longer time frame of data is needed to evaluate seasonality fully. Correlation coefficients generally declined with distance between monitors, while coefficients of divergence increased with distance. However, these trends were not statistically significant. PM10 levels exceeded Chinese and other health-based standards and guidelines. The review identified 13 studies on outdoor air pollution and health. Although limited, the studies indicate that air pollution is associated with increased risk of health outcomes in Lanzhou. These studies and the high air pollution levels suggest potentially serious health consequences. Findings can provide guidance to future epidemiological studies, monitor placement programs, and air quality policies. PMID:25838615

  9. Temperature ranges of the application of air-to-air heat recovery ventilator in supermarkets in winter, China

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yanming; Wang, Youjun; Zhong, Ke [School of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Liu, Jiaping [School of Architecture, Xi' an University of Architecture and Technology, Xi' an 710055 (China)

    2010-12-15

    Energy consumption is an important issue in China. In heating, ventilation and air conditioning (HVAC) systems, more and more commercial buildings use air-to-air heat recovery ventilators as energy saving units for recovering heat from the exhaust air in ventilation systems in current years. In the present paper, critical temperatures of air-to-air heat recovery systems for supermarkets in winter are recommended and discussed for the four cities in different climate zones of China. The analysis shows that the temperature of fresh air in winter can be categorized into three regions, i.e., recovery region, transition region and impermissible recovery region. The results also indicate that the latent heat recovery is not suitable for ventilation energy savings in supermarkets in winter. Meanwhile, the applicability of sensible heat recovery in supermarkets depends on outdoor climate and fresh air flow rate. If a variable rotational speed fan is used to introduce fresh air into the building, heat recovery does always function as planned in winter for all the selected cities except Guangzhou, and most values of the COP are much higher than 2.5. Otherwise, there is the risk of negative impact on building energy savings in all cities except Harbin. (author)

  10. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    DEFF Research Database (Denmark)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo

    2011-01-01

    America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation. The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two......Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some...... air cleaners are largely ineffective, and some produce harmful by-products. To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North...

  11. Appendicitis with Intraluminal Air

    International Nuclear Information System (INIS)

    Fernandez, Alfredo; Ramirez, Sandra M; Rodriguez, Cesar A; Uriza, Luis F

    2010-01-01

    The presentation of acute appendicitis with intraluminal air is an uncommon presentation. Ultrasound is a widely used and accepted to establish the diagnosis of appendicitis, but its performance is limited in situations where there is interposition of air. Inflamed appendix which presents with distension by gas can be source of error in ultrasound to establish a false negative diagnosis. In this article we present three patients with appendicitis where the interposition of intraluminal air hid their diagnostic by ultrasound. In all three cases the definitive diagnosis was established by computed tomography and surgical confirmation.

  12. Air movement - good or bad?

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2004-01-01

    when air movement is desirable and when it is not. At temperatures up to 22-23oC, at sedentary activity and with occupants feeling neutral or cooler there is a risk of air movement being perceived as unacceptable, even at low velocities. In particular, a cool overall thermal sensation negatively...... influences the subjective perception of air movement. With occupants feeling warmer than neutral, at temperatures above 23oC or at raised activity levels, humans generally do not feel draught at air velocities typical for indoor environments (up to around 0.4 m/s). In the higher temperature range, very high...

  13. Detonation of hydrogen-air mixtures

    International Nuclear Information System (INIS)

    Lee, J.H.S.; Knystautas, R.; Benedick, W.B.

    1983-01-01

    The detonation of a hydrogen-air cloud subsequent to an accidental release of hydrogen into ambient surroundings cannot be totally ruled out in view of the relative sensitivity of the hydrogen-air system. The present paper investigates the key parameters involved in hydrogen-air detonations and attempts to establish quantitative correlations between those that have important practical implications. Thus, for example, the characteristic length scale lambda describing the cellular structure of a detonation front is measured for a broad range of hydrogen-air mixtures and is quantitatively correlated with the key dynamic detonation properties such as detonability, transmission and initiation

  14. Responses of plants to air pollution

    National Research Council Canada - National Science Library

    Mudd, J. Brian; Kozlowski, T. T

    1975-01-01

    .... KOZLOWSKI Pollution, 1975 ELROY L. RICE. Allelopathy, (Eds.). Fire and Ecosystems, 1974 (Eds.). Responses of Plants to Air Responses of Plants to Air PollutionRESPONSES OF PLANTS TO AIR POLLUTION E...

  15. Indoor Air Pollution

    OpenAIRE

    Kirk R. Smith

    2003-01-01

    Outdoor air pollution in developing-country cities is difficult to overlook. Indoor air pollution caused by burning such traditional fuels as wood, crop residues, and dung is less evident, yet it is responsible for a significant part of country and global disease burdens. The main groups affected are poor women and children in rural areas and urban slums as they go about their daily activi...

  16. Corneal cell adhesion to contact lens hydrogel materials enhanced via tear film protein deposition.

    Directory of Open Access Journals (Sweden)

    Claire M Elkins

    Full Text Available Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS, borate buffered saline (BBS, or Sensitive Eyes Plus Saline Solution (Sensitive Eyes, either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.

  17. Advanced house air-barrier systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, R.K. [Natural Resources Canada, Ottawa, ON (Canada)

    1996-08-01

    Air barrier systems used in modern Canadian airtight homes were discussed. The Advanced Houses Program sets its airtightness requirements at 1.5 air changes per hour at 50 Pascals pressure difference (ACH{sub 5}0). In recent tests of 10 houses, it was suggested that a better airtightness level was attainable with average airtightness of about 1.0 ACH{sub 5}0. Six of the homes tested did not use the traditional polyethylene approach. Two of the houses used the airtight drywall approach, one used a foam system, and three used exterior air barriers. The advantages and disadvantages of each system was described, including cost effectiveness, cost reduction, performance and installation advantages. The confusion between an air barrier and a vapour diffusion retarder was explained. Exterior air barriers showed the greatest potential for meeting airtightness requirements at reasonable cost. 5 refs., 3 tabs.

  18. Investigating the air quality in aircraft cabins

    International Nuclear Information System (INIS)

    Nilsen, Steinar K.

    2002-01-01

    In recent years, there has been increasing concern about the air quality in aircraft cabins and its effects on health and safety for crew and passengers. Some of the major worries are risk of communication of infectious diseases, high incidence of respiratory diseases caused by low air moisture, and increased concentration of carbon dioxide from exhaled air due to the cabin air being recirculated. It also happens that fumes and gases enter the cabin by way of the ventilation system. This article describes the EU-funded research programme called CabinAir. The project aims to: (1) establish the current level of air quality in aircraft cabins, (2) establish the relationship between cabin air quality and the performance of environmental control and filtration systems, the air distribution, the energy consumption and the environmental impact of fuel burn. (3) develop new designs and technical solutions to improve the environmental control system and cabin air distribution/control systems, (4) optimise air quality in the cabin and minimise fuel consumption and environmental impacts, (5) develop performance specifications for the components, (6) draft European Pre-Normative Standards

  19. Stratospheric Air Sub-sampler (SAS) and its application to analysis of Delta O-17(CO2) from small air samples collected with an AirCore

    NARCIS (Netherlands)

    Mrozek, Dorota Janina; van der Veen, Carina; Hofmann, Magdalena E. G.; Chen, Huilin; Kivi, Rigel; Heikkinen, Pauli; Rockmann, Thomas

    2016-01-01

    We present the set-up and a scientific application of the Stratospheric Air Sub-sampler (SAS), a device to collect and to store the vertical profile of air collected with an AirCore (Karion et al., 2010) in numerous sub-samples for later analysis in the laboratory. The SAS described here is a 20m

  20. Air conditioning device for reactor buildings

    International Nuclear Information System (INIS)

    Kikuchi, Shiro.

    1982-01-01

    Purpose: To decrease the opening areas of pipe lines for an air conditioning device at the portions passing through the shielding walls of a reactor building for a FBR type reactor, as well as reduce the size of the building. Constitution: Airs in the building for containing reactor are liquefied in an air liquefying mechanism. The liquefied airs are sent by way of pipe lines to each of evaporators, wherein each of the chambers are cooled because of latent heat of evaporation and evaporated airs are released to each of the chambers. The airs released to each of the chambers are collected into an exhaust chamber and sent by way of a duct to the air liquefying mechanism and liquefied again. Since the volume of the liquefied airs may be smaller than the amount conventionally required for usual cooled airs, the pipe lines passing through the shielding walls of the building can be of smaller diameter. This can decrease the opening areas of the pipe lines at the portions passing through the walls of the shieldings and, since the opening areas are smaller, the structure of the radiation shieldings can be simplified in these portions. Further, since the space of the pipe lines in the building is reduced extremely, the size of the building can be reduced. (Moriyama, K.)

  1. Tracking air-related health should be an integrated part of air quality management in South Africa

    CSIR Research Space (South Africa)

    Wright, CY

    2010-09-01

    Full Text Available that the largest burden of air pollution related diseases is on developing countries where air pollution levels are also among the highest in the world. Air pollution may cause symptoms ranging from eyes, nose and throat irritation, exacerbation of asthma...

  2. Open air-vapor compression refrigeration system for air conditioning and hot water cooled by cool water

    International Nuclear Information System (INIS)

    Hou Shaobo; Li Huacong; Zhang Hefei

    2007-01-01

    This paper presents an open air-vapor compression refrigeration system for air conditioning and hot water cooled by cool water and proves its feasibility through performance simulation. Pinch technology is used in analysis of heat exchange in the surface heat exchanger, and the temperature difference at the pinch point is selected as 6 o C. Its refrigeration depends mainly on both air and vapor, more efficient than a conventional air cycle, and the use of turbo-machinery makes this possible. This system could use the cool in the cool water, which could not be used to cool air directly. Also, the heat rejected from this system could be used to heat cool water to 33-40 o C. The sensitivity analysis of COP to η c and η t and the simulated results T 4 , T 7 , T 8 , q 1 , q 2 and W m of the cycle are given. The simulations show that the COP of this system depends mainly on T 7 , η c and η t and varies with T 3 or T wet and that this cycle is feasible in some regions, although the COP is sensitive to the efficiencies of the axial compressor and turbine. The optimum pressure ratio in this system could be lower, and this results in a fewer number of stages of the axial compressor. Adjusting the rotation speed of the axial compressor can easily control the pressure ratio, mass flow rate and the refrigerating capacity. The adoption of this cycle will make the air conditioned room more comfortable and reduce the initial investment cost because of the obtained very low temperature air. Humid air is a perfect working fluid for central air conditioning and no cost to the user. The system is more efficient because of using cool water to cool the air before the turbine. In addition, pinch technology is a good method to analyze the wet air heat exchange with water

  3. Global Air Quality and Climate

    Science.gov (United States)

    Fiore, Arlene M.; Naik, Vaishali; Steiner, Allison; Unger, Nadine; Bergmann, Dan; Prather, Michael; Righi, Mattia; Rumbold, Steven T.; Shindell, Drew T.; Skeie, Ragnhild B.; hide

    2012-01-01

    Emissions of air pollutants and their precursors determine regional air quality and can alter climate. Climate change can perturb the long-range transport, chemical processing, and local meteorology that influence air pollution. We review the implications of projected changes in methane (CH4), ozone precursors (O3), and aerosols for climate (expressed in terms of the radiative forcing metric or changes in global surface temperature) and hemispheric-to-continental scale air quality. Reducing the O3 precursor CH4 would slow near-term warming by decreasing both CH4 and tropospheric O3. Uncertainty remains as to the net climate forcing from anthropogenic nitrogen oxide (NOx) emissions, which increase tropospheric O3 (warming) but also increase aerosols and decrease CH4 (both cooling). Anthropogenic emissions of carbon monoxide (CO) and non-CH4 volatile organic compounds (NMVOC) warm by increasing both O3 and CH4. Radiative impacts from secondary organic aerosols (SOA) are poorly understood. Black carbon emission controls, by reducing the absorption of sunlight in the atmosphere and on snow and ice, have the potential to slow near-term warming, but uncertainties in coincident emissions of reflective (cooling) aerosols and poorly constrained cloud indirect effects confound robust estimates of net climate impacts. Reducing sulfate and nitrate aerosols would improve air quality and lessen interference with the hydrologic cycle, but lead to warming. A holistic and balanced view is thus needed to assess how air pollution controls influence climate; a first step towards this goal involves estimating net climate impacts from individual emission sectors. Modeling and observational analyses suggest a warming climate degrades air quality (increasing surface O3 and particulate matter) in many populated regions, including during pollution episodes. Prior Intergovernmental Panel on Climate Change (IPCC) scenarios (SRES) allowed unconstrained growth, whereas the Representative

  4. Air-Sea Interaction

    Science.gov (United States)

    Csanady, G. T.

    2001-03-01

    In recent years air-sea interaction has emerged as a subject in its own right, encompassing small-scale and large-scale processes in both air and sea. Air-Sea Interaction: Laws and Mechanisms is a comprehensive account of how the atmosphere and the ocean interact to control the global climate, what physical laws govern this interaction, and its prominent mechanisms. The topics covered range from evaporation in the oceans, to hurricanes, and on to poleward heat transport by the oceans. By developing the subject from basic physical (thermodynamic) principles, the book is accessible to graduate students and research scientists in meteorology, oceanography, and environmental engineering. It will also be of interest to the broader physics community involved in the treatment of transfer laws, and thermodynamics of the atmosphere and ocean.

  5. Profit goal set for airBaltic

    Index Scriptorium Estoniae

    2011-01-01

    Latvijas Krajbanka president arvab, et airBalticu olukorra stabiliseerimiseks läheb vähemalt aasta. AirBalticu senine juht Bertolt Flick võib hakata uue Vilniuse lennukompanii investoriks. AirBalticu uuest juhatusest

  6. National Air Toxic Assessments (NATA) Results

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Air Toxics Assessment was conducted by EPA in 2002 to assess air toxics emissions in order to identify and prioritize air toxics, emission source types...

  7. 77 FR 5781 - Record of Decision for the Air Space Training Initiative Shaw Air Force Base, South Carolina...

    Science.gov (United States)

    2012-02-06

    ... DEPARTMENT OF DEFENSE Department of the Air Force Record of Decision for the Air Space Training Initiative Shaw Air Force Base, South Carolina Final Environmental Impact Statement ACTION: Notice of... signed the ROD for the Airspace Training Initiative Shaw Air Force Base, South Carolina Final...

  8. Sensitivity to draught in turbulent air flows

    Energy Technology Data Exchange (ETDEWEB)

    Todde, V

    1998-09-01

    Even though the ventilation system is designed to supply air flows at constant low velocity and controlled temperature, the resulting air movement in rooms is strongly characterised by random fluctuations. When an air flow is supplied from an inlet, a shear layer forms between the incoming and the standstill air in the room, and large scale vortices develops by coalescence of the vorticity shed at the inlet of the air supply. After a characteristically downstream distance, large scale vortices loose their identity because of the development of cascading eddies and transition to turbulence. The interaction of these vortical structures will rise a complicated three dimensional air movement affected by fluctuations whose frequencies could vary from fractions of Hz to several KHz. The perception and sensitivity to the cooling effect enhanced by these air movements depend on a number of factors interacting with each other: physical properties of the air flow, part and extension of the skin surface exposed to the air flow, exposure duration, global thermal condition, gender and posture of the person. Earlier studies were concerned with the percentage of dissatisfied subjects as a function of air velocity and temperature. Recently, experimental observations have shown that also the fluctuations, the turbulence intensity and the direction of air velocity have an important impact on draught discomfort. Two experimental investigations have been developed to observe the human reaction to horizontal air movements on bared skin surfaces, hands and neck. Attention was concentrated on the effects of relative turbulence intensity of air velocity and exposure duration on perception and sensitivity to the air movement. The air jet flows, adopted for the draught experiment in the neck, were also the object of an experimental study. This experiment was designed to observe the centre-line velocity of an isothermal circular air jet, as a function of the velocity properties at the outlet

  9. ARAMIS a regional air quality model for air pollution management: evaluation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Solar, M. R.; Gamez, P.; Olid, M.

    2015-07-01

    The aim of this research was to better understand the dynamics of air pollutants and to forecast the air quality over regional areas in order to develop emission abatement strategies for air pollution and adverse health effects. To accomplish this objective, we developed and applied a high resolution Eulerian system named ARAMIS (A Regional Air Quality Modelling Integrated System) over the north-east of Spain (Catalonia), where several pollutants exceed threshold values for the protection of human health. The results indicate that the model reproduced reasonably well observed concentrations, as statistical values fell within Environmental Protection Agency (EPA) recommendations and European (EU) regulations. Nevertheless, some hourly O{sub 3} exceedances in summer and hourly peaks of NO{sub 2} in winter were underestimated. Concerning PM10 concentrations less accurate model levels were obtained with a moderate trend towards underestimation during the day. (Author)

  10. ARAMIS a regional air quality model for air pollution management: evaluation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Soler, M.R.; Gamez, P.; Olid, M.

    2015-07-01

    The aim of this research was to better understand the dynamics of air pollutants and to forecast the air quality over regional areas in order to develop emission abatement strategies for air pollution and adverse health effects. To accomplish this objective, we developed and applied a high resolution Eulerian system named ARAMIS (A Regional Air Quality Modelling Integrated System) over the north-east of Spain (Catalonia), where several pollutants exceed threshold values for the protection of human health. The results indicate that the model reproduced reasonably well observed concentrations, as statistical values fell within Environmental Protection Agency (EPA) recommendations and European (EU) regulations. Nevertheless, some hourly O3 exceedances in summer and hourly peaks of NO2 in winter were underestimated. Concerning PM10 concentrations less accurate model levels were obtained with a moderate trend towards underestimation during the day. (Author)

  11. Health and efficiency in trimix versus air breathing in compressed air workers

    NARCIS (Netherlands)

    van Rees Vellinga, T. P.; Verhoeven, A. C.; van Dijk, F. J. H.; Sterk, W.

    2006-01-01

    The Western Scheldt Tunneling Project in the Netherlands provided a unique opportunity to evaluate the effects of trimix usage on the health of compressed air workers and the efficiency of the project. Data analysis addressed 318 exposures to compressed air at 3.9-4.4 bar gauge and 52 exposures to

  12. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  13. Studi Kelayakan Pengolahan Air Laut Menjadi Air Bersih di Kawasan Wisata dan Pelabuhan Perikanan Nusantara (PPN Pantai Prigi, Trenggalek

    Directory of Open Access Journals (Sweden)

    Agista Ayuningtyas Puspita Dwijayani

    2013-09-01

    Full Text Available Ketersediaan air bersih diperlukan pula dalam bidang kepariwisataan. Salah satunya ialah kawasan wisata alam Pantai Prigi, Trenggalek. Namun kondisi air saat ini masih memiliki kandungan TDS (Total Dissolved Solid dan salinitas yang cukup tinggi sehingga dibutuhkan suatu teknologi untuk mengolah air asin menjadi air tawar agar memenuhi standar baku mutu air bersih. Salah satu teknologi yang dapat diterapkan untuk mengolah air asin atau payau menjadi air tawar adalah dengan sistem Reverse Osmosis (RO. Penentuan kapasitas SWRO ditentukan dengan memproyeksikan jumlah pengunjung kawasan wisata Pantai Prigi dan kebutuhan air kolam apung hingga tahun 2023. Hasil proyeksi diperoleh kebutuhan air sebesar 729,40 m3/hari pada penggunaan maksimum. Dengan desain SWRO yaitu menggunakan pretreatment rapid sand filter dan filter karbon aktif untuk meremoval kandungan TDS, kesadahan total, khlorida, sulfat, dan bilangan KMnO4 (zat organik. Biaya yang dibutuhkan untuk membuat sistem pengolahan air laut dengan SWRO sebesar Rp 5.077.307.500,00.Perencanaan sistem pengolahan air laut menjadi layak jika air reject dari SWRO sebesar 1463,28 m3/hari dimanfaatkan menjadi wisata kolam apung, garam, dan air nigari dengan investasi total sebesar Rp 7.326.095.500,00. Dengan analisa kelayakan secara ekonomi  menggunakan prinsip ekonomi teknik, pada alternatif ini diperoleh nilai NPV sebesar Rp 25.024.360.250,24 ; IRR sebesar 23,7% ; dan Payback periode pada tahun ke-3 dengan keuntungan yang diperoleh Rp 3.915.665.044,80 per tahun.

  14. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  15. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  16. Air University Style and Author Guide

    National Research Council Canada - National Science Library

    Bassett, Marvin

    2005-01-01

    The "Air University Style and Author Guide" is designed to unify the writing of faculty, staff, and students of Air University stylistically, and to give them information about publishing with Air University (AU) Press...

  17. Experimental and Numerical Investigation of Effect of Air Stability on Exhaled Air Dispersion

    DEFF Research Database (Denmark)

    Xu, Chunwen; Gong, Guangcai; Nielsen, Peter Vilhelm

    2014-01-01

    studies. As the thermal stratification under displacement ventilation blocks the vertical movement of exhaled air, the exhaled contaminant may be trapped between temperature stratifications. As the dispersion of contaminant is closely related to the health of human indoors, the temperature structure...... was used for experimental study, and a numerical person was built to simulate the manikin. The velocity, temperature and concentration of tracer gas in exhaled air are affected by air stability to different degrees. The similarity of this effect among these parameters can also be observed through numerical...

  18. Cerebral Air Embolism in a Patient with a Tuberculous-Destroyed Lung during Commercial Air Travel: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hyun Seok; Jeong, Hae Woong; In, Hyun Sin [Dept. of Radiology, Pusan Paik Hospital, Inje University School of Medicine, Pusdan (Korea, Republic of)

    2011-08-15

    A cerebral air embolism is a rare cause of stroke, but may occur in patients undergoing invasive cardiac and pulmonary procedures, as well as in divers suffering pulmonary barotrauma from rapid ascent. A cerebral air embolism due to other causes, especially a change of air pressure from air travel, is particularly rare. Here, we report a case of cerebraenr embolism during commercial air travel in a patient with an tuberculous-destroyed lung.

  19. Maxwell Air Force Base

    Science.gov (United States)

    most effective style of leadership. (Courtesy Photo, Air University Press) Air University Press Directory Maxwell Links Welcome Leadership Joint Land Use Study Heritage Pamphlet Maxwell Driving Tour (No releases 'A Discourse on Winning and Losing' "Developing Your Full Range of Leadership" focuses

  20. Strategic Implications of U.S. Fighter Force Reductions: Air-to-Air Combat Modeling Using Lanchester Equations

    Science.gov (United States)

    2011-06-01

    STRATEGIC IMPLICATIONS OF US FIGHTER FORCE REDUCTIONS: AIR-TO-AIR COMBAT MODELING USING LANCHESTER ...TO-AIR COMBAT MODELING USING LANCHESTER EQUATIONS GRADUATE RESEARCH PAPER Presented to the Faculty Department of Operational Sciences...MODELING USING LANCHESTER EQUATIONS Ronald E. Gilbert, BS, MBA Major, USAF Approved

  1. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  2. Process air quality data

    Science.gov (United States)

    Butler, C. M.; Hogge, J. E.

    1978-01-01

    Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

  3. High Altitude Clear Air Turbulence Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Air Force Flight Dynamics Laboratory conducted the High Altitude Clear Air Turbulence Project in the mid 1960s with the intention of better understanding air...

  4. Phase I Recommendations by the Air Quality Management Work Group to the Clean Air Act Advisory Committee

    Science.gov (United States)

    Recommendations to the Clean Air Act Advisory Committee by Air Quality Management Work Group addressing the recommendations made by the National Research Council to improve the U.S. air quality management system.

  5. Cardiovascular effects of air pollution.

    Science.gov (United States)

    Bourdrel, Thomas; Bind, Marie-Abèle; Béjot, Yannick; Morel, Olivier; Argacha, Jean-François

    2017-11-01

    Air pollution is composed of particulate matter (PM) and gaseous pollutants, such as nitrogen dioxide and ozone. PM is classified according to size into coarse particles (PM 10 ), fine particles (PM 2.5 ) and ultrafine particles. We aim to provide an original review of the scientific evidence from epidemiological and experimental studies examining the cardiovascular effects of outdoor air pollution. Pooled epidemiological studies reported that a 10μg/m 3 increase in long-term exposure to PM 2.5 was associated with an 11% increase in cardiovascular mortality. Increased cardiovascular mortality was also related to long-term and short-term exposure to nitrogen dioxide. Exposure to air pollution and road traffic was associated with an increased risk of arteriosclerosis, as shown by premature aortic and coronary calcification. Short-term increases in air pollution were associated with an increased risk of myocardial infarction, stroke and acute heart failure. The risk was increased even when pollutant concentrations were below European standards. Reinforcing the evidence from epidemiological studies, numerous experimental studies demonstrated that air pollution promotes a systemic vascular oxidative stress reaction. Radical oxygen species induce endothelial dysfunction, monocyte activation and some proatherogenic changes in lipoproteins, which initiate plaque formation. Furthermore, air pollution favours thrombus formation, because of an increase in coagulation factors and platelet activation. Experimental studies also indicate that some pollutants have more harmful cardiovascular effects, such as combustion-derived PM 2.5 and ultrafine particles. Air pollution is a major contributor to cardiovascular diseases. Promotion of safer air quality appears to be a new challenge in cardiovascular disease prevention. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Air ambulance medical transport advertising and marketing.

    Science.gov (United States)

    2011-01-01

    The National Association of EMS Physicians (NAEMSP), the American College of Emergency Physicians (ACEP), the Air Medical Physician Association (AMPA), the Association of Air Medical Services (AAMS), and the National Association of State EMS Officials (NASEMSO) believe that patient care and outcomes are optimized by using air medical transport services that are licensed air ambulance providers with robust physician medical director oversight and ongoing quality assessment and review. Only air ambulance medical transport services with these credentials should advertise/market themselves as air ambulance services.

  7. Air permitting of IGCC plants

    Energy Technology Data Exchange (ETDEWEB)

    Chitikela, S.R.

    2007-07-01

    The IGCC process is, currently, the preferred choice over conventional thermal power production in regard to cleanup of fuel and significantly reduced contaminant emissions. The air permitting requirements include the review of: feed preparation and PM emissions; feed gasification and contaminant emissions; elemental sulfur recovery and SO{sub 2} emissions; options for carbon-dioxide recovery; syngas characteristics for combustion; CT design and combustion mechanisms; air contaminant emissions of CT; controlled CT emissions of nitrogen-oxides and carbon-monoxide gases using the SCR and oxidation catalysts, respectively; and, emission of volatile organic compounds (VOCs), and hazardous air pollutants (HAPs). However, the IGCC processes are being rigorously reviewed for the system integration and reliability, and significant reduction of air contaminant emissions (including the greenhouse gases). This paper included a review of IGCC air contaminant emission rates, and various applicable regulatory requirements, such as NSR (New Source Review), NSPS (New Source Performance Standards), and MACT (Maximum Achievable Control Technology). The IGCC facility's NOX, CO, SO{sub 2}, PM, VOCs, and HAPs emission rates would be significantly low. Thus, effective, construction and installation, and operation air permits would be necessary for IGCC facilities.

  8. Compressed-air power tools in orthopaedic surgery: exhaust air is a potential source of contamination.

    Science.gov (United States)

    Sagi, H C; DiPasquale, Thomas; Sanders, Roy; Herscovici, Dolfi

    2002-01-01

    To determine if the exhaust from surgical compressed-air power tools contains bacteria and if the exhaust leads to contamination of sterile surfaces. Bacteriologic study of orthopaedic power tools. Level I trauma center operative theater. None. Part I. Exhaust from two sterile compact air drills was sampled directly at the exhaust port. Part II. Exhaust from the drills was directed at sterile agar plates from varying distances. The agar plates represented sterile surfaces within the operative field. Part III. Control cultures. A battery-powered drill was operated over open agar plates in similar fashion as the compressed-air drills. Agar plates left open in the operative theater served as controls to rule out atmospheric contamination. Random cultures were taken from agar plates, gloves, drills, and hoses. Incidence of positive cultures. In Part I, all filters from both compressed-air drill exhausts were culture negative ( = 0.008). In Part II, the incidence of positive cultures for air drills number one and number two was 73% and 82%, respectively. The most commonly encountered organisms were, coagulase-negative Staphylococcus, and Micrococcus species. All control cultures from agar plates, battery-powered drill, gloves, and hoses were negative ( compressed-air power tools in orthopaedic surgery may contribute to the dissemination of bacteria onto the surgical field. We do not recommend the use of compressed-air power tools that do not have a contained exhaust.

  9. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  10. Population Dynamics and Air Pollution

    DEFF Research Database (Denmark)

    Flachs, Esben Meulengracht; Sørensen, Jan; Bønløkke, Jacob

    2013-01-01

    Objective. To explore how three different assumptions on demographics affect the health impact of Danish emitted air pollution in Denmark from 2005 to 2030, with health impact modeled from 2005 to 2050. Methods. Modeled air pollution from Danish sources was used as exposure in a newly developed......) a static year 2005 population, (2) morbidity and mortality fixed at the year 2005 level, or (3) an expected development. Results. The health impact of air pollution was estimated at 672,000, 290,000, and 280,000 lost life years depending on demographic assumptions and the corresponding social costs at 430.......4 M€, 317.5 M€, and 261.6 M€ through the modeled years 2005–2050. Conclusion. The modeled health impact of air pollution differed widely with the demographic assumptions, and thus demographics and assumptions on demographics played a key role in making health impact assessments on air pollution....

  11. Acute effect of ambient air pollution on stroke mortality in the China air pollution and health effects study.

    Science.gov (United States)

    Chen, Renjie; Zhang, Yuhao; Yang, Chunxue; Zhao, Zhuohui; Xu, Xiaohui; Kan, Haidong

    2013-04-01

    There have been no multicity studies on the acute effects of air pollution on stroke mortality in China. This study was undertaken to examine the associations between daily stroke mortality and outdoor air pollution (particulate matter air pollution with daily stroke mortality. Air pollution was associated with daily stroke mortality in 8 Chinese cities. In the combined analysis, an increase of 10 μg/m(3) of 2-day moving average concentrations of particulate matter air pollution and risk of stroke mortality. To our knowledge, this is the first multicity study in China, or even in other developing countries, to report the acute effect of air pollution on stroke mortality. Our results contribute to very limited data on the effect of air pollution on stroke for high-exposure settings typical in developing countries.

  12. 78 FR 47191 - Air Quality Designations for the 2010 Sulfur Dioxide (SO2) Primary National Ambient Air Quality...

    Science.gov (United States)

    2013-08-05

    ... Air Quality Designations for the 2010 Sulfur Dioxide (SO[bdi2]) Primary National Ambient Air Quality... air quality designations for certain areas in the United States for the 2010 primary Sulfur Dioxide (SO 2 ) National Ambient Air Quality Standard (NAAQS). The EPA is issuing this rule to identify areas...

  13. 77 FR 34122 - Application of Sun Air Express, LLC, d/b/a Sun Air International for Commuter Authority

    Science.gov (United States)

    2012-06-08

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary [Docket DOT-OST-2011-0169] Application of Sun Air Express, LLC, d/b/a Sun Air International for Commuter Authority AGENCY: Department of... order finding Sun Air Express, LLC d/b/a Sun Air International fit, willing, and able, and awarding it...

  14. Air pollution and mortality in Barcelona.

    OpenAIRE

    Sunyer, J; Castellsagué, J; Sáez, M; Tobias, A; Antó, J M

    1996-01-01

    STUDY OBJECTIVES: Studies conducted in Barcelona reported a short term relation between daily air pollutant values and emergency department admissions for exacerbation of chronic obstructive pulmonary diseases and asthma. Air pollution in Barcelona is mainly generated by vehicle exhaust and is below the World Health Organization air quality guidelines. The acute relation between air pollution and mortality was assessed. DESIGN: Daily variations in total mortality, mortality in subjects older ...

  15. Surgically Shaping a Financial Hydra: Reprogramming United States Air Force End Strength to the Air Reserve Component

    Science.gov (United States)

    2012-02-14

    Director of the Air National Guard20 Lt Gen Charles E. Stenner Jr., Chief of the Air Force Reserve21 Specificity about what rebalancing the force...January 2012). Sharp, Travis. Vision Meets Reality: 2010 QDR and 2011 Defense Budget. Center for a New American Security, February 2010. Stenner ...Lt Gen Charles E. Stenner Jr., commander of Air Force Reserve Command (address, Air Force Reserve Senior Leader Conference

  16. 76 FR 2744 - Disclosure of Code-Share Service by Air Carriers and Sellers of Air Transportation

    Science.gov (United States)

    2011-01-14

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Disclosure of Code-Share Service by Air Carriers and Sellers of Air Transportation AGENCY: Office of the Secretary, Department of Transportation..., their agents, and third party sellers of air transportation in view of recent amendments to 49 U.S.C...

  17. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  18. Cost/benefit evaluation of electrofibrous air filters

    International Nuclear Information System (INIS)

    Bergman, W.; Kuhl, W.; Biermann, A.; Lum, B.

    1986-01-01

    Experimental electric air filters based on the principle of superimposing an electric field over conventional fibrous air filters have been developed. The different experimental electric filters described in this report include prefilters for use in glove boxes and in ventilation systems, re-circulating air filters, electric HEPA filters, and high efficiency, high temperature air filters. In each case the large improvement in filter efficiency that occurs when a mechanical filter is electrified is demonstrated. Also a significant increase in the particle loading capacity of filters in many of our evaluations is demonstrated. Both laboratory and field test results are presented. This paper also demonstrates that the performance of all of our electric filter designs, except one, can be matched by conventional mechanical air filters and usually at a lower cost. The one exception is the high temperature, high efficiency electric air filter. In that case there is no mechanical filter media that can match the performance of the electric air filter. Our findings show that electric air filters are only cost effective compared to mechanical air filters when the performance of the mechanical air filter cannot be further improved by mechanical means. (author)

  19. Air pollution control in practice

    International Nuclear Information System (INIS)

    Baum, F.

    1988-01-01

    The book offers a comprehensive treatment of the subject, from air pollution monitoring and effects on human and animal health, on plants and materials, to pollution reduction measures, practical applications, and legal regulations. It intends to give the air pollution expert a basis for developing practicable solutions. Apart from the 'classic' pollutants, also radioactive air pollution is gone into. (DG) With 366 figs., 190 tabs [de

  20. Air quality dispersion models from energy sources

    International Nuclear Information System (INIS)

    Lazarevska, Ana

    1996-01-01

    Along with the continuing development of new air quality models that cover more complex problems, in the Clean Air Act, legislated by the US Congress, a consistency and standardization of air quality model applications were encouraged. As a result, the Guidelines on Air Quality Models were published, which are regularly reviewed by the Office of Air Quality Planning and Standards, EPA. These guidelines provide a basis for estimating the air quality concentrations used in accessing control strategies as well as defining emission limits. This paper presents a review and analysis of the recent versions of the models: Simple Terrain Stationary Source Model; Complex Terrain Dispersion Model; Ozone,Carbon Monoxide and Nitrogen Dioxide Models; Long Range Transport Model; Other phenomenon Models:Fugitive Dust/Fugitive Emissions, Particulate Matter, Lead, Air Pathway Analyses - Air Toxic as well as Hazardous Waste. 8 refs., 4 tabs., 2 ills

  1. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  2. Carbon captured from the air

    International Nuclear Information System (INIS)

    Keith, D.

    2008-01-01

    This article presented an innovative way to achieve the efficient capture of atmospheric carbon. A team of scientists from the University of Calgary's Institute for Sustainable Energy, Environment and Economy have shown that it is possible to reduce carbon dioxide (CO 2 ) using a simple machine that can capture the trace amount of CO 2 present in ambient air at any place on the planet. The thermodynamics of capturing the small concentrations of CO 2 from the air is only slightly more difficult than capturing much larger concentrations of CO 2 from power plants. The research is significant because it offers a way to capture CO 2 emissions from transportation sources such as vehicles and airplanes, which represent more than half of the greenhouse gases emitted on Earth. The energy efficient and cost effective air capture technology could complement other approaches for reducing emissions from the transportation sector, such as biofuels and electric vehicles. Air capture differs from carbon capture and storage (CCS) technology used at coal-fired power plants where CO 2 is captured and pipelined for permanent storage underground. Air capture can capture the CO 2 that is present in ambient air and store it wherever it is cheapest. The team at the University of Calgary showed that CO 2 could be captured directly from the air with less than 100 kWhrs of electricity per tonne of CO 2 . A custom-built tower was able to capture the equivalent of 20 tonnes per year of CO 2 on a single square meter of scrubbing material. The team devised a way to use a chemical process from the pulp and paper industry to cut the energy cost of air capture in half. Although the technology is only in its early stage, it appears that CO 2 could be captured from the air with an energy demand comparable to that needed for CO 2 capture from conventional power plants, but costs will be higher. The simple, reliable and scalable technology offers an opportunity to build a commercial-scale plant. 1 fig

  3. Air pollution episodes in Stockholm regional background air due to sources in Europe and their effects on human population

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, C. [Swedish Meteorological and Hydrological Inst., Norrkoping (Sweden)], E-mail: camilla.andersson@smhi.se; Joensson, O. [Stockholm Univ. (Sweden). Dept. of Applied Environmental Science; Forsberg, B. [Umea Univ. (Sweden), Occupational and Environmental Medicine; Johansson, C. [Environmental and Health Administration, Stockholm (Sweden)

    2013-09-01

    Using air quality measurements, we categorized air pollution according to source sectors in a rural background environment in southern Sweden based on hourly air-mass backward trajectories during 1997-2010. Concentrations of fine (PM{sub 2.5}) and sum of fine and coarse particulate matter (PM{sub 10}), accumulation mode particle number, black carbon and surface ozone were 4.0, 3.9, 4.5, 6.8 and 1.3 times higher, respectively, in air masses from the southeast as compared with those in air masses from the cleanest sector in the northwest, consistent with air-mass transport over areas with relatively high emissions of primary particulate matter (PM) and secondary PM precursors. The highest ultrafine particle numbers were associated with clean air from the northwest. We estimate that almost 7.8% and 0.6% higher premature human mortality is caused by PM{sub 2.5} and ozone exposure, respectively, when air originates from the southeast as compared with that when air originates from the northwest. Reductions of emissions in eastern Europe would reduce the highest air pollution concentrations and associated health risks. However, since air masses from the southwest are more frequent, emissions in the western part of Europe are more important for annual mean premature mortality. (orig.)

  4. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  5. Ambient air pollution and semen quality.

    Science.gov (United States)

    Nobles, Carrie J; Schisterman, Enrique F; Ha, Sandie; Kim, Keewan; Mumford, Sunni L; Buck Louis, Germaine M; Chen, Zhen; Liu, Danping; Sherman, Seth; Mendola, Pauline

    2018-05-01

    Ambient air pollution is associated with systemic increases in oxidative stress, to which sperm are particularly sensitive. Although decrements in semen quality represent a key mechanism for impaired fecundability, prior research has not established a clear association between air pollution and semen quality. To address this, we evaluated the association between ambient air pollution and semen quality among men with moderate air pollution exposure. Of 501 couples in the LIFE study, 467 male partners provided one or more semen samples. Average residential exposure to criteria air pollutants and fine particle constituents in the 72 days before ejaculation was estimated using modified Community Multiscale Air Quality models. Generalized estimating equation models estimated the association between air pollutants and semen quality parameters (volume, count, percent hypo-osmotic swollen, motility, sperm head, morphology and sperm chromatin parameters). Models adjusted for age, body mass index, smoking and season. Most associations between air pollutants and semen parameters were small. However, associations were observed for an interquartile increase in fine particulates ≤2.5 µm and decreased sperm head size, including -0.22 (95% CI -0.34, -0.11) µm 2 for area, -0.06 (95% CI -0.09, -0.03) µm for length and -0.09 (95% CI -0.19, -0.06) µm for perimeter. Fine particulates were also associated with 1.03 (95% CI 0.40, 1.66) greater percent sperm head with acrosome. Air pollution exposure was not associated with semen quality, except for sperm head parameters. Moderate levels of ambient air pollution may not be a major contributor to semen quality. Published by Elsevier Inc.

  6. Air cleaning using regenerative silica gel wheel

    DEFF Research Database (Denmark)

    Fang, Lei

    2011-01-01

    This paper discussed the necessity of indoor air cleaning and the state of the art information on gas-phase air cleaning technology. The performance and problems of oxidation and sorption air cleaning technology were summarized and analysed based on the literature studies. Eventually, based...... on an experimental study, a technology called clean air heat pump is proposed as a practical approach for indoor air cleaning....

  7. Perceived air quality, thermal comfort, and SBS symptoms at low air temperature and increased radiant temperature

    DEFF Research Database (Denmark)

    Toftum, Jørn; Reimann, Gregers Peter; Foldbjerg, P.

    2002-01-01

    source present at the low temperature. To maintain overall thermal neutrality, the low air temperature was partly compensated for by individually controlled radiant heating, and partly by allowing subjects to modify clothing insulation. A reduction of the air temperature from 23 deg.C to 18 deg.......C suggested an improvement of the perceived air quality, while no systematic effect on symptom intensity was observed. The overall indoor environment was evaluated equally acceptable at both temperatures due to local thermal discomfort at the low air temperature....

  8. Strategy Guideline. Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  9. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  10. Global thermal analysis of air-air cooled motor based on thermal network

    Science.gov (United States)

    Hu, Tian; Leng, Xue; Shen, Li; Liu, Haidong

    2018-02-01

    The air-air cooled motors with high efficiency, large starting torque, strong overload capacity, low noise, small vibration and other characteristics, are widely used in different department of national industry, but its cooling structure is complex, it requires the motor thermal management technology should be high. The thermal network method is a common method to calculate the temperature field of the motor, it has the advantages of small computation time and short time consuming, it can save a lot of time in the initial design phase of the motor. The domain analysis of air-air cooled motor and its cooler was based on thermal network method, the combined thermal network model was based, the main components of motor internal and external cooler temperature were calculated and analyzed, and the temperature rise test results were compared to verify the correctness of the combined thermal network model, the calculation method can satisfy the need of engineering design, and provide a reference for the initial and optimum design of the motor.

  11. Indoor air quality/air infiltration in selected low-energy houses

    International Nuclear Information System (INIS)

    Shohl Wagner, B.; Phillips, T.J.

    1984-01-01

    Indoor air quality and air infiltration were measured in 16 low-energy California houses. Eleven has gas stoves; all had average infiltration rates of 0.5 h -1 of less, recent construction dates, low natural ventilation, and no mechanical ventilation. HCHO levels in 12 houses and radon-222 and NO 2 levels in all houses were measured using passive monitors. Blower door measurements and local weather data were used to calculate average infiltration rates during the monitoring period. Correlation of pollutant concentrations with infiltration rates and building characteristics indicate that new houses with average heating season infiltration rates less than 0.5 h -1 do not necessarily experience poor indoor air quality, HCHO and radon-222 levels in new houses exceeded the lowest currently proposed standards or guidelines, and much higher levels probably exist elsewhere. Therefore, some strategy for identifying 'problem' houses is needed. We recommend an approach for future research in this area. (Author)

  12. On the performance of air conditioner with heat pipe for cooling air in the condenser

    Energy Technology Data Exchange (ETDEWEB)

    Naphon, Paisarn, E-mail: paisarnn@swu.ac.t [Thermo-Fluids and Heat Transfer Enhancement Laboratory (TFHT), Department of Mechanical Engineering, Faculty of Engineering, Srinakharinwirot University, 63 Rangsit-Nakhornnayok Rd., Ongkharak, Nakhorn-Nayok 26120 (Thailand)

    2010-11-15

    Improvement of the air conditioning system performance by using the heat pipe for cooling air before entering the condenser is presented. In the experiment, the heat pipe is fabricated from the straight copper tube with the diameter and length of 10, 600 mm, respectively. The arrangements of the heat pipe sets are arranged in the staggered layout with the tube rows of 1, 2, 3. R134a refrigerant is used as working fluid in the heat pipe set for this present study. By comparing with a conventional air conditioning system, the air conditioning system with three rows of heat pipe gives the highest COP and EER with increasing of 6.4%, 17.5%, respectively. On the global warming and environment problems, the results of this study are expected to lead to guidelines that will allow the improved performance of the air conditioning systems which reduce its energy consumption.

  13. On the performance of air conditioner with heat pipe for cooling air in the condenser

    International Nuclear Information System (INIS)

    Naphon, Paisarn

    2010-01-01

    Improvement of the air conditioning system performance by using the heat pipe for cooling air before entering the condenser is presented. In the experiment, the heat pipe is fabricated from the straight copper tube with the diameter and length of 10, 600 mm, respectively. The arrangements of the heat pipe sets are arranged in the staggered layout with the tube rows of 1, 2, 3. R134a refrigerant is used as working fluid in the heat pipe set for this present study. By comparing with a conventional air conditioning system, the air conditioning system with three rows of heat pipe gives the highest COP and EER with increasing of 6.4%, 17.5%, respectively. On the global warming and environment problems, the results of this study are expected to lead to guidelines that will allow the improved performance of the air conditioning systems which reduce its energy consumption.

  14. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    Science.gov (United States)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  15. Modeling activities in air traffic control systems: antecedents and consequences of a mid-air collision.

    Science.gov (United States)

    de Carvalho, Paulo Victor R; Ferreira, Bemildo

    2012-01-01

    In this article we present a model of some functions and activities of the Brazilian Air traffic Control System (ATS) in the period in which occurred a mid-air collision between flight GLO1907, a commercial aircraft Boeing 737-800, and flight N600XL, an executive jet EMBRAER E-145, to investigate key resilience characteristics of the ATM. Modeling in some detail activities during the collision and related them to overall behavior and antecedents that stress the organization uncover some drift into failure mechanisms that erode safety defenses provided by the Air Navigation Service Provider (ANSP), enabling a mid-air collision to be happen.

  16. Factors affecting hydrocarbon removal by air stripping

    International Nuclear Information System (INIS)

    McFarland, W.E.

    1992-01-01

    This paper includes an overview of the theory of air stripping design considerations and the factors affecting stripper performance. Effects of temperature, contaminant characteristics, stripping tower geometry and air/water ratios on removal performance are discussed. The discussion includes treatment of groundwater contaminated with petroleum hydrocarbons and chlorinated solvents such as TCE and PCE. Control of VOC emissions from air strippers has become a major concern in recent years, due to more stringent restrictions on air quality in many areas. This paper includes an overview of available technology to control air emissions (including activated carbon adsorption, catalytic oxidation and steam stripping) and the effects of air emission control on overall efficiency of the treatment process. The paper includes an overview of the relative performance of various packing materials for air strippers and explains the relative advantages and disadvantages of comparative packing materials. Field conditions affecting selection of packing materials are also discussed. Practical guidelines for the design of air stripping systems are presented, as well as actual case studies of full-scale air stripping projects

  17. Portland cement concrete air content study.

    Science.gov (United States)

    1987-04-20

    This study took the analysis of Portland cement concrete air content. Based on the information gathered, this study hold the results were : 1) air-entrained concrete was more durable than non-air entrained concrete all other factors being equal; 2) A...

  18. Air pollution

    International Nuclear Information System (INIS)

    Nelson, P.

    2000-01-01

    Australian cites experience a number of current and emerging air pollution problems. Concentrations of traditional primary pollutants such as CO, lead and dust have fallen in recent years as a consequence of air pollutant control measures, and the widespread introduction of lead-free petrol. However, recommended guidelines for ozone, the principal component of photochemical smog, are regularly exceeded in major capital cities in the summer months. In addition, it is predicted that extensive urban expansion will lead to much greater dependence on the motor vehicle as the primary means of transportation. Effects of air pollution are felt at a variety of scales. Traditionally, concerns about gaseous and particulate emissions from industrial and vehicular sources were focused on local impacts due to exposure to toxic species such as CO and lead. As noted above, concentrations of these pollutants have been reduced by a variety of control measures. Pollutants which have effects at a regional scale, such as photochemically-produced ozone, and acidic gases and particles have proved more difficult to reduce. In general, these pollutants arc not the result of direct emissions to atmosphere, but result from complex secondary processes driven by photochemical reactions of species such as NO 2 and aldehydes. In addition, global effects of gaseous and particulate emissions to the atmosphere have received significant recent attention, concentrations of atmospheric CO 2 with predicted impacts on global climate, and ozone depletion due to anthropogenic emissions of chlorine-containing chemicals are the two major examples. Combustion processes from petrol- and diesel-fuelled vehicles, make major contributions to air pollution, and the magnitude of this contribution is discussed in this article

  19. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants

    NARCIS (Netherlands)

    Scheepers, P.T.J.; Wel, L. van; Beckmann, G.; Anzion, R.B.M.

    2017-01-01

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two

  20. Chemical Characterization of the Indoor Air Quality of a University Hospital : Penetration of Outdoor Air Pollutants

    NARCIS (Netherlands)

    Scheepers, Paul T J; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B M

    2017-01-01

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two

  1. Recovering heat from waste air from stables

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    A milk cow gives off 35.7 kW h/d via its body, excreta and urine. 68.4% of this is body heat. Part of this waste heat escapes with the waste air from the cowsheds. The heat can be recovered from the waste air by an air/air heat exchanger. The air is collected and taken to a heat exchanger. In the heat exchanger, fresh air is heated by the waste air, and is distributed over the cowshed by a system of ducts. The heated waste air escapes through a central chimney at the end of the heat exchanger. It is sensible to fit the heat exchanger above the cowshed roof, if there is sufficient space available and the chimney should run upwards from the cowshed. A double heat exchanger makes it possible to allocate each half of the cowshed to half of the heat exchanger.

  2. Experimental Analysis on Solar Desiccant Air Conditioner

    OpenAIRE

    Dr. U. V. Kongre, C. M. Singh, A. B. Biswas

    2014-01-01

    The experiment investigated and evaluated the feasibility of an solar desiccant air conditioner. Its effectiveness as a possible air conditioner option used in household air conditioner or as an energy efficient and environmentally friendly alternative to conventional air conditioning units used in houses are evaluated. A solar water heater was used as heat gain. The model utilizes the technology of solar air conditioner system. The purpose in the long term wou...

  3. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  4. Nitric oxide density measurements in air and air/fuel nanosecond pulse discharges by laser induced fluorescence

    International Nuclear Information System (INIS)

    Uddi, M; Jiang, N; Adamovich, I V; Lempert, W R

    2009-01-01

    Laser induced fluorescence is used to measure absolute nitric oxide concentrations in air, methane-air and ethylene-air non-equilibrium plasmas, as a function of time after initiation of a single pulse, 20 kV peak voltage, 25 ns pulse duration discharge. A mixture of NO and nitrogen with known composition (4.18 ppm NO) is used for calibration. Peak NO density in air at 60 Torr, after a single pulse, is ∼8 x 10 12 cm -3 (∼4.14 ppm) occurring at ∼250 μs after the pulse, with decay time of ∼16.5 ms. Peak NO atom mole fraction in a methane-air mixture with equivalence ratio of ψ = 0.5 is found to be approximately equal to that in air, with approximately the same rise and decay rate. In an ethylene-air mixture (also with equivalence ratio of ψ = 0.5), the rise and decay times are comparable to air and methane-air, but the peak NO concentration is reduced by a factor of approximately 2.5. Spontaneous emission measurements show that excited electronic states N 2 (C 3 Π) and NO(A 2 Σ) in air at P = 60 Torr decay within ∼20 ns and ∼1 μs, respectively. Kinetic modelling calculations incorporating air plasma kinetics complemented with the GRI Mech 3.0 hydrocarbon oxidation mechanism are compared with the experimental data using three different NO production mechanisms. It is found that NO concentration rise after the discharge pulse is much faster than predicted by Zel'dovich mechanism reactions, by two orders of magnitude, but much slower compared with reactions of electronically excited nitrogen atoms and molecules, also by two orders of magnitude. It is concluded that processes involving long lifetime (∼100 μs) metastable states, such as N 2 (X 1 Σ,v) and O 2 (b 1 Σ), formed by quenching of the metastable N 2 (A 3 Σ) state by ground electronic state O 2 , may play a dominant role in NO formation. NO decay, in all cases, is found to be dominated by the reverse Zel'dovich reaction, NO + O → N + O 2 , as well as by conversion into NO 2 in a reaction

  5. Nitric oxide density measurements in air and air/fuel nanosecond pulse discharges by laser induced fluorescence

    Science.gov (United States)

    Uddi, M.; Jiang, N.; Adamovich, I. V.; Lempert, W. R.

    2009-04-01

    Laser induced fluorescence is used to measure absolute nitric oxide concentrations in air, methane-air and ethylene-air non-equilibrium plasmas, as a function of time after initiation of a single pulse, 20 kV peak voltage, 25 ns pulse duration discharge. A mixture of NO and nitrogen with known composition (4.18 ppm NO) is used for calibration. Peak NO density in air at 60 Torr, after a single pulse, is ~8 × 1012 cm-3 (~4.14 ppm) occurring at ~250 µs after the pulse, with decay time of ~16.5 ms. Peak NO atom mole fraction in a methane-air mixture with equivalence ratio of phiv = 0.5 is found to be approximately equal to that in air, with approximately the same rise and decay rate. In an ethylene-air mixture (also with equivalence ratio of phiv = 0.5), the rise and decay times are comparable to air and methane-air, but the peak NO concentration is reduced by a factor of approximately 2.5. Spontaneous emission measurements show that excited electronic states N2(C 3Π) and NO(A 2Σ) in air at P = 60 Torr decay within ~20 ns and ~1 µs, respectively. Kinetic modelling calculations incorporating air plasma kinetics complemented with the GRI Mech 3.0 hydrocarbon oxidation mechanism are compared with the experimental data using three different NO production mechanisms. It is found that NO concentration rise after the discharge pulse is much faster than predicted by Zel'dovich mechanism reactions, by two orders of magnitude, but much slower compared with reactions of electronically excited nitrogen atoms and molecules, also by two orders of magnitude. It is concluded that processes involving long lifetime (~100 µs) metastable states, such as N2(X 1Σ,v) and O2(b 1Σ), formed by quenching of the metastable N2(A 3Σ) state by ground electronic state O2, may play a dominant role in NO formation. NO decay, in all cases, is found to be dominated by the reverse Zel'dovich reaction, NO + O → N + O2, as well as by conversion into NO2 in a reaction of NO with ozone.

  6. Intraoperative air leak measured after lobectomy is associated with postoperative duration of air leak.

    Science.gov (United States)

    Brunelli, Alessandro; Salati, Michele; Pompili, Cecilia; Gentili, Paolo; Sabbatini, Armando

    2017-11-01

    To verify the association between the air leak objectively measured intraoperatively (IAL) using the ventilator and the air leak duration after pulmonary lobectomy. Prospective analysis on 111 patients submitted to pulmonary lobectomy (33 by video-assisted thoracic surgery). After resection, objective assessment of air leak (in milliliter per minute) was performed before closure of the chest by measuring the difference between a fixed inspired and expired volume, using a tidal volume of 8 ml/kg, a respiratory rate of 10 and a positive-end expiratory pressure of 5 cmH2O. A multivariable analysis was performed for identifying factors associated with duration of postoperative air leak. Average IAL was 158 ml/min (range 0-1500 ml/min). The best cut-off (receiver-operating characteristics analysis) associated with air leak longer than 5 days was 500 ml/min. Nine patients had IAL >500 ml/min (8%). They had a longer duration of postoperative air leak compared with those with a lower IAL (mean values, 10.1 days, SD 8.8 vs 1.5 days, SD 4.9 P leak duration after multivariable regression: left side resection (P = 0.018), upper site resection (P = 0.031) and IAL >500 ml/min (P leak duration was generated: 1.7 + 2.4 × left side + 2.2 × upper site + 8.8 × IAL >500. The air leak measurement using the ventilator parameters after lung resection may assist in estimating the risk of postoperative prolonged air leak. An IAL > 500 ml/min may warrant the use of intraoperative preventative measures, particularly after video-assisted thoracic surgery lobectomy where a submersion test is often unreliable. © 2017 European Society of Cardiology and European Atherosclerosis Association. All rights reserved. For permissions please email: journals.permissions@oup.com.

  7. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    International Nuclear Information System (INIS)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M.

    2011-01-01

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper.

  8. Rectal perforation by compressed air.

    Science.gov (United States)

    Park, Young Jin

    2017-07-01

    As the use of compressed air in industrial work has increased, so has the risk of associated pneumatic injury from its improper use. However, damage of large intestine caused by compressed air is uncommon. Herein a case of pneumatic rupture of the rectum is described. The patient was admitted to the Emergency Room complaining of abdominal pain and distension. His colleague triggered a compressed air nozzle over his buttock. On arrival, vital signs were stable but physical examination revealed peritoneal irritation and marked distension of the abdomen. Computed tomography showed a large volume of air in the peritoneal cavity and subcutaneous emphysema at the perineum. A rectal perforation was found at laparotomy and the Hartmann procedure was performed.

  9. Air congestion delay: a review

    Directory of Open Access Journals (Sweden)

    Daniel Alberto Pamplona

    2016-04-01

    Full Text Available This article is a literature review of the air congestion delay and its costs. Air congestion is a worldwide problem. Its existence brings costs for airlines and discomfort for passengers. With the increasing demand for air transport, the study of air congestion has attracted the attention of many researchers around the world. The cause for the delays is erroneously attributed only to the lack of infrastructure investments. The literature review shows that other factors such as population growth, increasing standards of living, lack of operational planning and environmental issues exercise decisive influence. Several studies have been conducted in order to analyze and propose solutions to this problem that affects society as a whole.

  10. Radionuclides in ground-level air

    International Nuclear Information System (INIS)

    Sinkko, K.

    1987-01-01

    In the air surveillance programme the concentrations of artificial radionuclides are monitored in the air close to the ground to obtain the necessary basic data for estimating the exposure of the Finnish population to fall-out radionuclides and also to detect atmospheric traces of radioactive materials caused by their use or production. Airborne dust is collected on filters with high-volume air samplers and the concentrations of gamma-emitting radionuclides in the air are evaluated. In the first quarter of 1986 only long-lived cesium, caused by earlier atmospheric nuclear explosions was detected. The concentrations of cesium were very low. In January and March a small amount of short-lived, fresh fission and activation products were also observed

  11. Air tamponade of the heart.

    Science.gov (United States)

    Gołota, Janusz J; Orłowski, Tadeusz; Iwanowicz, Katarzyna; Snarska, Jadwiga

    2016-06-01

    Pneumopericardium is a rare disease defined as the presence of air or gas in the pericardial sac. Among the etiological factors, the following stand out: chest trauma, barotrauma, air-containing fistulas between the pericardium and the surrounding structures, secondary gas production by microorganisms growing in the pericardial sac, and iatrogenic factors. Until now, spontaneous pneumopericardium has been considered a harmless and temporary state, but a review of clinical cases indicates that the presence of air in the pericardium can lead to cardiac tamponade and life-threatening hemodynamic disturbances. We present the case of an 80-year-old patient with a chronic bronchopericardial fistula, who suffered from a cardiac arrest due to air tamponade of the heart.

  12. Over the air test

    DEFF Research Database (Denmark)

    2015-01-01

    [1] This invention relates to over-the-air testing of a device in an anechoic chamber. In particular, the invention is suitable for simulating both uplink and downlink over-the-air communication with a device under test even when the anechoic chamber has different numbers of uplink and downlink...

  13. Air Force Senior Leaders

    Science.gov (United States)

    Force TV Radio Week in Photos About Us Air Force Senior Leaders SECAF CSAF CMSAF Biographies Adjunct Professors Senior Mentor Biographies Fact Sheets Commander's Call Topics CCT Archive CSAF Reading List 2017 Media Sites Site Registration Contact Us Search AF.mil: Home > About Us > Air Force Senior Leaders

  14. Assessment of indoor air quality in comparison using air conditioning and fan system in printing premise

    Directory of Open Access Journals (Sweden)

    Ramlan Nazirah

    2017-01-01

    Full Text Available Printers contribute to various emissions consist with chemical contaminants. High concentration of the particulate matter can cause serious health problems. This study focuses on the indoor air quality in printing premise unit in Universiti Tun Hussein Onn, Malaysia. Field testing involving air sampling methods were taken from 900 hours to 1600 hours, for every 30 minutes using physical measurement which is Multi-Channel Air Quality Monitor (YESAIR, E-Sampler and Ozone Meter. Air sampling was recorded based on one sampling point and most suitable point for production. A comparison based on different ventilation using fan and air-conditioning were also taken and results is being compared based on OSHA and NIOSH standards. Besides that, the statistical analysis is being conducted in order to predict the effect on number of printers. From the result, the O3 concentrations show, 10% reduced for printing premise using fan ventilation compared to air-conditioning but remain the same value for PM2.5. The concentration of O3 increased when the number of printers decreased, while the concentration of PM2.5 increased the increase of printers number. Overall, the use of fan in printing premise is more suggested since the level is slightly lower than the printing premise using air-conditioning.

  15. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  16. Inhomogeneous electric field air cleaner

    International Nuclear Information System (INIS)

    Schuster, B.G.

    1976-01-01

    For applications requiring the filtration of air contaminated with enriched uranium, plutonium or other transuranium compounds, it appears desirable to collect the material in a fashion more amenable to recovery than is now practical when material is collected on HEPA filters. In some instances, it may also be desirable to use an air cleaner of this type to substantially reduce the loading to which HEPA filters are subjected. A theoretical evaluation of such an air cleaner considers the interaction between an electrically neutral particle, dielectric or conducting, with an inhomogeneous electric field. An expression is derived for the force exerted on a particle in an electrode configuration of two concentric cylinders. Equations of motion are obtained for a particle suspended in a laminar flow of air passing through this geometry. An electrical quadrupole geometry is also examined and shown to be inferior to the cylindrical one. The results of two separate configurations of the single cell prototypes of the proposed air cleaner are described. These tests were designed to evaluate collection efficiencies using mono-disperse polystyrene latex and polydisperse NaCl aerosols. The advantages and problems of such systems in terms of a large scale air cleaning facility will be discussed

  17. Electric utilities and clean air

    International Nuclear Information System (INIS)

    Evans, J.E.

    1991-01-01

    This paper reports that electricity has become essential to American life. Approximately 70 percent of the nation's electricity is produced by burning fossil fuels, with coal, the most abundant, domestically-available, extracted natural resource, providing over 55 percent of the total electricity consumed. Emissions resulting from the burning of fossil fuels are regulated by both the federal and state governments. In 1970, Congress passed the comprehensive Clean Air Act which established a national program to protect the nation's air quality. In 1977, additional strict regulations were passed, which mandated even more stringent emission controls for factories, power plants and auto emissions. Prior to passage of the Clean Air Act of 1990, utilities were required to adhere to three major types of clean air regulations: National Ambient Air Quality Standards (NAAQS), New Source Performance Standards (NSPS), and Prevention of Significant Deterioration (PSD) review. NAAQS established limits for the maximum concentration levels of specific air pollutants in the ambient atmosphere. For example, for an area to be in compliance with the NAAQS for sulfur dioxide (SO 2 ), its annual average SO 2 concentration must not exceed 0.03 ppm of SO 2 and a peak 24 hour level of 0.14 ppm of SO 2 must not be exceeded more than once per year

  18. Outdoor air pollution and sperm quality.

    Science.gov (United States)

    Lafuente, Rafael; García-Blàquez, Núria; Jacquemin, Bénédicte; Checa, Miguel Angel

    2016-09-15

    Exposure to air pollution has been clearly associated with a range of adverse health effects, including reproductive toxicity, but its effects on male semen quality are still unclear. We performed a systematic review (up to June 2016) to assess the impact of air pollutants on sperm quality. We included 17 semi-ecological, panel, and cohort studies, assessing outdoor air pollutants, such as PM2.5, PM10, NOx, SO2, and O3, and their effects on DNA fragmentation, sperm count, sperm motility, and sperm morphology. Thirteen studies assessed air pollution exposure measured environmentally, and six used biomarkers of air pollution exposure (two did both). We rated the studies using the Newcastle-Ottawa Scale and assessed with the exposure method. Taking into account these factors and the number of studies finding significant results (positive or negative), the evidence supporting an effect of air pollution on DNA fragmentation is weak but suggestive, on sperm motility is limited and probably inexistent, on lower sperm count is inconclusive, and on sperm morphology is very suggestive. Because of the diversity of air pollutants and sperm parameters, and the studies' designs, we were unable to perform a meta-analysis. In summary, most studies concluded that outdoor air pollution affects at least one of the four semen quality parameters included in the review. However, results lack consistency, and furthermore, studies were not comparable. Studies using standardized air pollution and semen measures are required to obtain more reliable conclusions. CRD42015007175. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. 49 CFR 173.166 - Air bag inflators, air bag modules and seat-belt pretensioners.

    Science.gov (United States)

    2010-10-01

    ... generant and, in some cases, a pressure vessel (cylinder)) is a gas generator used to inflate an air bag in... domestic transportation by highway, rail freight, cargo vessel or cargo aircraft, a serviceable air bag...

  20. Air Turbulence and sensation of draught

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Melikov, Arsen Krikor; Hanzawa, H.

    1988-01-01

    the sedentary subjects were exposed to six mean air velocities ranging from 0.05 m/s to 0.40 m/s. The air temperature was kept constant at 23°C. They were asked whether and where they could feel air movement and whether or not it felt uncomfortable. The turbulence intensity had a significant impact...... on the occurence of draught sensation. A model is presented which predicts the percentage of people dissatisfied because of draught as a function of air temperature, mean velocity and turbulence intensity. The model can be a useful tool for quantifying the draught risk in spaces and for developing air distribution...... systems with a low draught risk....

  1. Air contamination analysis during emergency medical treatment

    International Nuclear Information System (INIS)

    Yamada, Y.; Fukutsu, K.; Yuuki, M.; Akashi, M.

    2009-01-01

    After radiological emergencies, patients contaminated with radioactivity are taken to radiation emergency hospitals for treatment. Numerical simulations using the computer software 'Flow Designer R were made in order to evaluate indoor air contamination caused by the breathing out of contaminated air. The National Inst. of Radiological Sciences facility was used for the numerical evaluation. Results indicate that the dispersion of contaminated air depends on the characteristics of the contaminants, and that the dispersion range was limited and localised. Only medical staff standing in a special position near the patient was exposed to almost un-diluted contaminated air. Highly contaminated air was evacuated with a local exhaust pump system. Room air quality was monitored using a continuous air sampling system, but it was found that the sampling point was not representative for the purpose of radiation protection. From the air-flow analysis, some problems that affect radiological safety were revealed and valuable information and measures for preventing secondary contamination were determined. (authors)

  2. [Working ability between air and trimix breathing gas under 8 ATA air condition].

    Science.gov (United States)

    Shibayama, M; Kosugi, S; Mohri, M; Yamamura, I; Oda, S; Kimura, A; Takeuchi, J; Mano, Y

    1990-04-01

    Pneumatic caisson work in Japan has come into operation since 1924. Afterward, this technique of compressed air work has been widely utilized in the construction of foundation basements, shafts of the bottom tunnel shields for subway and so forth. While using this technique of compressed air work means that workers have to be exposed to hyperbaric environment, this technique has risks of not only decompression sickness (DCS) but also toxicity of poisonous gas and/or oxygen deficiency. However, this technique is independent of city construction work and the operation of compressed air work higher than 5ATA (4.0 kg/cm2G) is actually been planning recently. Accordingly unmanned caisson work is considered as a better technique for such higher pressurized work, even though workers must enter into hyperbaric working fields for maintenance or repair of unmanned operated machinery and materials. This research is to establish the safe work under hyperbaric air environment at 8ATA.

  3. KAJIAN ANALISIS PERBANDINGAN JUMLAH PEMANFAATAN AIR TANAH

    Directory of Open Access Journals (Sweden)

    Acep Hidayat

    2017-02-01

    Full Text Available Perkembangan pertumbuhan kota meningkat sehingga fenomena yang berkaitan dengan sumber daya air semakin meningkat. Pertumbuhan penduduk setiap tahun bertambah menyertai pertumbuhan kota, menjadikan pemanfaatan air tanah semakin meningkat. Fenomena yang terjadi adalah bahwa ketersediaan lahan untuk prosesnya terjadinya resapan air ke dalam tanah semakin berkurang, dimana luasan lahan yang ada sangat tidak mencukupi resapan air ke dalam tanah. Di samping itu, resapan air ke dalam tanah dipengaruhi tingkat permeabilitas dari jenis tanah pada lingkungan daerah sekitar resapan. Akibat dari jumlah resapan air ke dalam tanah yang tidak seimbang dengan jumlah pemakaian air tanah yang digunakan mengakibatkan terjadinya penurunan muka air tanah dengan disertai penurunan lapisan tanah. Bila hal ini terjadi secara terus menerus menjadikan elevasi permukaan tanah akan lebih rendah dari permukaan laut. Untuk mengantisipasi hal tersebut terjadi, maka penelitian ini melakukan kajian tingkat permeabilitas daya resap air untuk macam jenis tanah dengan melakukan tes-tes tanah, sehingga dapat diketahui titik imbang antara jumlah air tanah yang dapat diambil dengan air yang dapat meresap ke dalam tanah. Berdasarkan perhitungan curah hujan didapat bahwa besar curah hujan dalam satu tahun sebesar 54.56 m3/detik dan yang meresap hanya 5.37 m3/detik atau 9.84 %. Hal ini menunjukkan bahwa jenis tanah di sekitar wilayah penelitian berjenis lanau dan clay, sehingga mempunyai angka pori yang kecil. Dengan kondisi tersebut maka wilayah tersebut dapat diprogramkan dengan membuat folder-folder tampungan, sumur-sumur resapan, lubang-lubang biopori dan lainya.

  4. Air tight electrical box

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, C.G.

    1990-08-14

    An air-impervious electrical box to facilitate air sealing a house comprises an integral, rigid box body having a continuous flange, integral with the body, circumscribing and outwardly extending from the sides of the body. This flange is rearwardly positioned behind the front edges of the sides of the body a predetermined distance so that the electrical box may be secured to framing by nailing through the flange. Drywall is then secured to the frame on top of and adjecent to the flange. Such box eliminates the necessity for solid backing and minimizes passage of air through the box and space between the drywall and the box.

  5. Air and metal hydride battery

    Energy Technology Data Exchange (ETDEWEB)

    Lampinen, M.; Noponen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Applied Thermodynamics

    1998-12-31

    The main goal of the air and metal hydride battery project was to enhance the performance and manufacturing technology of both electrodes to such a degree that an air-metal hydride battery could become a commercially and technically competitive power source for electric vehicles. By the end of the project it was possible to demonstrate the very first prototype of the air-metal hydride battery at EV scale, achieving all the required design parameters. (orig.)

  6. 30 CFR 77.412 - Compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air systems. 77.412 Section 77.412... for Mechanical Equipment § 77.412 Compressed air systems. (a) Compressors and compressed-air receivers... involving the pressure system of compressors, receivers, or compressed-air-powered equipment shall not be...

  7. The measurement of low air flow velocities

    NARCIS (Netherlands)

    Aghaei, A.; Mao, X.G.; Zanden, van der A.J.J.; Schaik, W.H.J.; Hendriks, N.A.

    2005-01-01

    Air flow velocity is measured with an acoustic sensor, which can be used especially for measuring low air flow velocities as well as the temperature of the air simultaneously. Two opposite transducers send a sound pulse towards each other. From the difference of the transit times, the air flow

  8. Formal Methods Applications in Air Transportation

    Science.gov (United States)

    Farley, Todd

    2009-01-01

    The U.S. air transportation system is the most productive in the world, moving far more people and goods than any other. It is also the safest system in the world, thanks in part to its venerable air traffic control system. But as demand for air travel continues to grow, the air traffic control system s aging infrastructure and labor-intensive procedures are impinging on its ability to keep pace with demand. And that impinges on the growth of our economy. Air traffic control modernization has long held the promise of a more efficient air transportation system. Part of NASA s current mission is to develop advanced automation and operational concepts that will expand the capacity of our national airspace system while still maintaining its excellent record for safety. It is a challenging mission, as efforts to modernize have, for decades, been hamstrung by the inability to assure safety to the satisfaction of system operators, system regulators, and/or the traveling public. In this talk, we ll provide a brief history of air traffic control, focusing on the tension between efficiency and safety assurance, and the promise of formal methods going forward.

  9. The "Family Tree" of Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    2011-01-01

    In this paper all total volume air distribution principles are addressed based on discussions of air flow pattern in a room with heat sources giving a cooling load. The supply and exhaust air openings are considered to have different locations and sizes in the room, and it is possible to show tha...... conditions which are not used for air distribution in general. A number of experiments with different air distribution systems are addressed, and they illustrate the behaviour at the different conditions discussed in the paper....... that all the known types of air distribution systems are interconnected in a “family tree”. The influence of supplied momentum flow versus buoyancy forces is discussed, and geometries for high ventilation effectiveness are indicated as well as geometries for fully mixed flow. The paper will also show......In this paper all total volume air distribution principles are addressed based on discussions of air flow pattern in a room with heat sources giving a cooling load. The supply and exhaust air openings are considered to have different locations and sizes in the room, and it is possible to show...

  10. Air compressor efficiency in a Vietnamese enterprise

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ming [3E and T International, Suite 1506, Building No. 10, Luo Ma Shi Street, Xuan Wu District, Beijing 100052 (China)

    2009-06-15

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%. (author)

  11. Air compressor efficiency in a Vietnamese enterprise

    Energy Technology Data Exchange (ETDEWEB)

    Yang Ming [3E and T International, Suite 1506, Building No. 10, Luo Ma Shi Street, Xuan Wu District, Beijing 100052 (China)], E-mail: ming.yang7@gmail.com

    2009-06-15

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%.

  12. Air compressor efficiency in a Vietnamese enterprise

    International Nuclear Information System (INIS)

    Yang Ming

    2009-01-01

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%.

  13. Representativeness of air quality monitoring networks

    NARCIS (Netherlands)

    Duyzer, J.; Hout, D. van den; Zandveld, P.; Ratingen, S. van

    2015-01-01

    The suitability of European networks to check compliance with air quality standards and to assess exposure of the population was investigated. An air quality model (URBIS) was applied to estimate and compare the spatial distribution of the concentration of nitrogen dioxide (NO2) in ambient air in

  14. Indoor Air Quality in Chemistry Laboratories.

    Science.gov (United States)

    Hays, Steve M.

    This paper presents air quality and ventilation data from an existing chemical laboratory facility and discusses the work practice changes implemented in response to deficiencies in ventilation. General methods for improving air quality in existing laboratories are presented and investigation techniques for characterizing air quality are…

  15. Air defense planning for an area with the use of very short range air defense sets

    Directory of Open Access Journals (Sweden)

    Tadeusz Pietkiewicz

    2017-12-01

    Full Text Available This paper presents a heuristic method of planning the deployment of very short-range anti-air missile and artillery sets (VSHORAD around an area (‘protected area’ in order to protect it. A function dependent on the distance between the earliest feasible points of destroying targets and the centre of the protected area was taken as an objective function. This is a different indicator from those commonly used in the literature, and based on the likelihood of a defense zone penetration by means of an air attack (MAA: the kill probability of the MAA and the probability of area losses. The model constraints resulted directly from the restrictions imposed by real air defense systems and the nature of the area being defended. This paper assumes that the VSHORAD system operates as a part of a general, superordinate air defense command and control system based on the idea of network-centric warfare, which provides the VSHORAD system with a recognized air picture, air defense plans, and combat mission specifications. The presented method has been implemented. The final part of the paper presents the computational results. Keywords: optimal planning, air defense system, area installation protection, deployment of very short range anti-air missile and artillery sets (VSHORAD

  16. Air medical transport of cardiac patients.

    Science.gov (United States)

    Essebag, Vidal; Halabi, Abdul R; Churchill-Smith, Michael; Lutchmedial, Sohrab

    2003-11-01

    The air medical transport of cardiac patients is a rapidly expanding practice. For various medical, social, and economic indications, patients are being flown longer distances at commercial altitudes, including international and intercontinental flights. There are data supporting the use of short-distance helicopter flights early in the course of a cardiac event for patients needing emergent transfer for percutaneous coronary intervention or aortocoronary bypass. When considering elective long-distance air medical transport of cardiac patients for social or economic reasons, it is necessary to weigh the benefits against the potential risks of flight. A few recent studies suggest that long-distance air medical transport is safe under certain circumstances. Current guidelines for air travel after myocardial infarction do not address the use of medical escorts or air ambulances equipped with intensive care facilities. Further research using larger prospective studies is needed to better define criteria for safe long-distance air medical transport of cardiac patients.

  17. Study of air traffic over KLFIR

    Science.gov (United States)

    Nusyirwan, I. F.; Rohani, J. Mohd

    2017-12-01

    This paper shares the overview of the work currently being conducted with the Department of Civil Aviation Malaysia related to the air traffic. The aim is to study air traffic performance over KL and KK FIR, and the area of interest in this paper is the Kuala Lumpur Flight Information Region (KLFIR). The air traffic performance parameters includes general air traffic movement such as level allocation, number of movements, sector load analysis and also more specific parameters such as airborne delays, effects of weather to the air movements as well as ground delays. To achieve this, a huge effort has been undertaken that includes live data collection algorithm development and real time statistical analysis algorithm development. The main outcome from this multi-disciplinary work is the long-term analysis on the air traffic performance in Malaysia, which will put the country at par in the aviation community, namely the International Civil Aviation Organization (ICAO).

  18. Urban air quality management. V. 1

    International Nuclear Information System (INIS)

    1997-01-01

    This is the first in a series of reports commissioned by the International Petroleum Industry Environmental Conservation Association (IPIECA) to represent members' views on the management of urban air quality in the growing cities in developing countries. In this report, a general, science based framework is provided as a basis for understanding the nature of the problem in any specific urban area, the range of solutions that might be available, and the potential impact of each solution and its least cost privatisation. The topics covered are: a process for urban air quality management; setting air quality targets; a structured approach to the assessment of current and future air quality modelling methodologies; identification and collation of air quality model input data; development of socio-economic scenarios -long-term trend forecasting; cost effectiveness studies; the IPIECA approach to urban air quality management - development of partnerships; encouraging commitment to implementation of programme recommendations. (7 figures; 2 tables; 18 references). (UK)

  19. Applying policy and health effects of air pollution in South Korea: focus on ambient air quality standards

    Science.gov (United States)

    Ha, Jongsik

    2014-01-01

    Objectives South Korea’s air quality standards are insufficient in terms of establishing a procedure for their management. The current system lacks a proper decision-making process and prior evidence is not considered. The purpose of this study is to propose a measure for establishing atmospheric environmental standards in South Korea that will take into consideration the health of its residents. Methods In this paper, the National Ambient Air Quality Standards (NAAQS) of the US was examined in order to suggest ways, which consider health effects, to establish air quality standards in South Korea. Up-to-date research on the health effects of air pollution was then reviewed, and tools were proposed to utilize the key results. This was done in an effort to ensure the reliability of the standards with regard to public health. Results This study showed that scientific research on the health effects of air pollution and the methodology used in the research have contributed significantly to establishing air quality standards. However, as the standards are legally binding, the procedure should take into account the effects on other sectors. Realistically speaking, it is impossible to establish standards that protect an entire population from air pollution. Instead, it is necessary to find a balance between what should be done and what can be done. Conclusions Therefore, establishing air quality standards should be done as part of an evidence-based policy that identifies the health effects of air pollution and takes into consideration political, economic, and social contexts. PMID:25300297

  20. Application of air ions for bacterial de-colonization in air filters contaminated by aerosolized bacteria

    International Nuclear Information System (INIS)

    Kim, Yang Seon; Yoon, Ki Young; Park, Jae Hong; Hwang, Jungho

    2011-01-01

    We aerosolized the Escherichia coli (E. coli) and Staphylococcus epidermidis (S. epidermidis) bacteria and collected them on membrane filters. Then we generated air ions by applying a high voltage to a carbon fiber tip and applied them to the contaminated filters. The antibacterial efficiency was not significantly affected by the bacteria being Gram-positive or Gram-negative, however, negative ions showed a lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions. With a field emission scanning electron microscope (FE-SEM) images and fluorescence microscopy images using a LIVE/DEAD BacLight Bacterial Viability Kit, electrostatic disruption of the bacteria was found to be the dominant antibacterial effect. - Research Highlights: →This study examined the effects of air ions generated by a carbon fiber ionizer on the inactivation of bioaerosols. →When the ion exposure time and the ion generation concentration were increased, the antibacterial efficiency increased. →The bioaerosols carried a significant number of negative electrical charges. →Negative ions showed lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions.

  1. Overcurrent Abuse of Primary Prismatic Zinc–Air Battery Cells Studying Air Supply Effects on Performance and Safety Shut-Down

    Directory of Open Access Journals (Sweden)

    Fredrik Larsson

    2017-01-01

    Full Text Available Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn–Air battery cells with full air supply as well as with shut-off air supply. Compared to other battery technologies, e.g., lithium-ion batteries, metal–air batteries offer the possibility to physically stop the battery operation by stopping its air supply, thus offering an additional protection against severe battery damage in the case of, e.g., an accidental short circuit. This method may also reduce the electrical hazard in a larger battery system since, by stopping the air supply, the voltage can be brought to zero while maintaining the energy capacity of the battery. Measurements of overdischarge currents and current cut-off by suffocation have been performed to assess the safety of this type of Zn–air battery. The time to get to zero battery voltage is shown to mainly be determined by the volume of air trapped in the cell.

  2. Air Markets Program Data (AMPD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Markets Program Data tool allows users to search EPA data to answer scientific, general, policy, and regulatory questions about industry emissions. Air...

  3. A survey of perfluoroalkyl sulfonamides in indoor and outdoor air using passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Shoeib, M.; Harner, T. [Meteorological Service of Canada, Environment Canada (Canada); Wilford, B.; Jones, K. [Lancaster Univ. (United Kingdom). Environmental Science; Zhu, J. [Chemistry Research Division, Health Canada, Tunney' s Pasture, Ottawa (Canada)

    2004-09-15

    Perfluorooctane sulfonate (PFOS) has recently emerged as a priority environmental pollutant due to its widespread detection in biological samples from remote regions including the Arctic and the Mid-North Pacific Ocean. Because PFOS is fairly involatile, it is hypothesized that its occurrence in remote regions is the result of atmospheric transport of more volatile precursor compounds such as the perfluoroalkyl sulfonamides (PFASs). PFASs are used in variety of consumer products for water and oil resistance including surface treatments for fabric, upholstery, carpet, paper and leather. In a recent pilot study employing high volume air samples, indoor air concentrations of PFASs were approximately 100 times greater than outdoor levels. This is of significance because people typically spend about 90% of their time indoors 5 and this exposure may serve as an important uptake pathway. Indoor air also serves as a source of PFASs to the outside where PFASs are ultimately transported and distributed throughout the environment. The current study is intended to be a more comprehensive survey of indoor and outdoor air allowing more confident conclusions to be made. Passive air samplers comprised of polyurethane foam (PUF) disks were used. These are quiet, non-intrusive samplers that operate without the aid of a pump or electricity. Air movement delivers chemical to the sampler which has a high retention capacity for persistent organic pollutants (POPs). PUF disks samplers have been previously used successfully to monitor different classes of hydrophobic persistent organic pollutants POPs.

  4. High-energy metal air batteries

    Science.gov (United States)

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2013-07-09

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  5. Carbon captured from the air

    Energy Technology Data Exchange (ETDEWEB)

    Keith, D. [Calgary Univ., AB (Canada)

    2008-10-15

    This article presented an innovative way to achieve the efficient capture of atmospheric carbon. A team of scientists from the University of Calgary's Institute for Sustainable Energy, Environment and Economy have shown that it is possible to reduce carbon dioxide (CO{sub 2}) using a simple machine that can capture the trace amount of CO{sub 2} present in ambient air at any place on the planet. The thermodynamics of capturing the small concentrations of CO{sub 2} from the air is only slightly more difficult than capturing much larger concentrations of CO{sub 2} from power plants. The research is significant because it offers a way to capture CO{sub 2} emissions from transportation sources such as vehicles and airplanes, which represent more than half of the greenhouse gases emitted on Earth. The energy efficient and cost effective air capture technology could complement other approaches for reducing emissions from the transportation sector, such as biofuels and electric vehicles. Air capture differs from carbon capture and storage (CCS) technology used at coal-fired power plants where CO{sub 2} is captured and pipelined for permanent storage underground. Air capture can capture the CO{sub 2} that is present in ambient air and store it wherever it is cheapest. The team at the University of Calgary showed that CO{sub 2} could be captured directly from the air with less than 100 kWhrs of electricity per tonne of CO{sub 2}. A custom-built tower was able to capture the equivalent of 20 tonnes per year of CO{sub 2} on a single square meter of scrubbing material. The team devised a way to use a chemical process from the pulp and paper industry to cut the energy cost of air capture in half. Although the technology is only in its early stage, it appears that CO{sub 2} could be captured from the air with an energy demand comparable to that needed for CO{sub 2} capture from conventional power plants, but costs will be higher. The simple, reliable and scalable technology

  6. 75 FR 66728 - Action Affecting Export Privileges; Orion Air, S.L. and Syrian Pearl Airlines: Orion Air, S.L...

    Science.gov (United States)

    2010-10-29

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Action Affecting Export Privileges; Orion Air, S.L. and Syrian Pearl Airlines: Orion Air, S.L., Canada Real de Merinas, 7 Edificio 5, 3'A... Denying the Export Privileges of Respondents Orion Air, S.L. (``Orion Air'') and Syrian Pearl Airlines...

  7. Indigenous high volume air sampler

    International Nuclear Information System (INIS)

    Kotrappa, P.; Setty, N.P.N.; Raghunath, B.; Sivasubrahmanyam, P.S.

    1978-01-01

    A high volume air sampler for use in assessing concentrations of low levels of air borne particulates has been fabricated. The sampler will be of use in radioactive installations, conventional industries and environmental pollution analysis. It is comparable in performance with the imported Staplex air samplers. A turbine and motor system similar to the one found in conventional vacuum cleaners is used in its design. The sampler units can be produced in large numbers. (M.G.B.)

  8. Air pollution: Impact and prevention

    OpenAIRE

    SIERRA-VARGAS, MARTHA PATRICIA; TERAN, LUIS M

    2012-01-01

    ABSTRACT Air pollution is becoming a major health problem that affects millions of people worldwide. In support of this observation, the World Health Organization estimates that every year, 2.4 million people die because of the effects of air pollution on health. Mitigation strategies such as changes in diesel engine technology could result in fewer premature mortalities, as suggested by the US Environmental Protection Agency. This review: (i) discusses the impact of air pollution on respirat...

  9. Air Pollution and Environmental Justice Awareness

    Science.gov (United States)

    Bouvier-Brown, N. C.

    2014-12-01

    Air pollution is not equally dispersed in all neighborhoods and this raises many social concerns, such as environmental justice. "Real world" data, whether extracted from online databases or collected in the field, can be used to demonstrate air quality patterns. When students explore these trends, they not only learn about atmospheric chemistry, but they also become socially aware of any inequities. This presentation outlines specific ways to link air pollution and environmental justice suitable for an undergraduate upper division Air Pollution or Atmospheric Chemistry course.

  10. Air Compliance Complaint Database (ACCD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — THIS DATA ASSET NO LONGER ACTIVE: This is metadata documentation for the Region 7 Air Compliance Complaint Database (ACCD) which logs all air pollution complaints...

  11. Odor and the Clean Air Act

    International Nuclear Information System (INIS)

    Morse, H.N.

    1993-01-01

    The case described in this paper involves the interpretation of language contained in the Texas Clean Air Act Texas Health and Safety Code Ann. Sections 382.001-382.141. The State of Texas, on behalf of the Texas Air Control Board, brought suit in the District Court of Erath County, Texas against the F/R Cattle Company, Inc., alleging that, because of odors emanating from the company's cattle feeding facility, the company was violating the Clean Air Act. The Board is granted the power and duty to administer the Clean Air Act and is directed to accomplish the purposes of the Act through the control of air contaminants by all practical and economically feasible methods. Described here is the evidence presented at and proceedings of the trial

  12. Air suctioning during colon biopsy forceps removal reduces bacterial air contamination in the endoscopy suite.

    Science.gov (United States)

    Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M

    2010-09-01

    Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  13. Can the Air Pollution Index be used to communicate the health risks of air pollution?

    International Nuclear Information System (INIS)

    Li, Li; Lin, Guo-Zhen; Liu, Hua-Zhang; Guo, Yuming; Ou, Chun-Quan; Chen, Ping-Yan

    2015-01-01

    The validity of using the Air Pollution Index (API) to assess health impacts of air pollution and potential modification by individual characteristics on air pollution effects remain uncertain. We applied distributed lag non-linear models (DLNMs) to assess associations of daily API, specific pollution indices for PM 10 , SO 2 , NO 2 and the weighted combined API (APIw) with mortality during 2003–2011 in Guangzhou, China. An increase of 10 in API was associated with a 0.88% (95% confidence interval (CI): 0.50, 1.27%) increase of non-accidental mortality at lag 0–2 days. Harvesting effects appeared after 2 days’ exposure. The effect estimate of API over lag 0–15 days was statistically significant and similar with those of pollutant-specific indices and APIw. Stronger associations between API and mortality were observed in the elderly, females and residents with low educational attainment. In conclusion, the API can be used to communicate health risks of air pollution. - Highlights: • The cumulative effects of API on mortality over lag 0–15 days remained significant. • The indices for three specific pollutants had similar associations with mortality. • The effects of API were modified by age, gender and educational attainment. • Our findings can help to communicate health risks of air pollution to the public. - The Air Pollution Index communicates health risks of air pollution

  14. Kualitas Air Hujan dan Faktor Lingkungan yang Mempengaruhinya

    Directory of Open Access Journals (Sweden)

    S Sudarmadji

    2016-07-01

    Full Text Available Hujan merupakan masukan dalam sistem hidrologi. Ditinjau dari kualitasnya dibandingkan dengan air aami lainnya, air hujan merupakan air paling murni dalam arti komposisinya hampir mendekati H2O. Namun demikian, pada hakekatnya tidak pernah dijumpai air hujan yang betul-betul hanya tersusun atas H2O saja, berbagai faktor lingkungan telah mempengaruhi kualitas air hujan tersebut. Pencemaran udara yang terjadi di kota-kota besar, baik yang berupa buangan gas maupun emisi dari kendaraan bermotor. Serta buangan gas dari pabrik telah mempengaruhi kualitas air hujan yang jatuh di daerah kota. Air hujan di daerah pantai juga terpengaruh oleh laut dengan segala aktifitas dan komposisi airnya. Di daerah gunung api yang masih aktif air hujan juga dipengaruhi oleh aktifitas tersebut. Masing-masing lingkungan tersebut di atas mempengaruhi komposisi air hujan. Kajian kualitas air hujan dilakukan dengan mengambil hasil penelitian yang dilakukan oleh peneliti sebelumnya di daerah pulau Jawa, namun demikian hasil penelitian yang dilakukan di luar negeri juga digunakan sebagai pembanding.

  15. Compliance with air quality regulations

    International Nuclear Information System (INIS)

    Steen, D.V.; Tackett, D.L.

    1990-01-01

    Due to the probable passage of Clean Air Act Amendments in 1990, electric utilities throughout the United States are faced with numerous choices to comply with the new acid rain regulations, expected in 1991. The choice of a compliance plan is not a simple task. Every compliance option will be costly. At Ohio Edison, deliberations are quite naturally influenced by past compliance with air quality regulations. This paper discusses compliance with air quality regulations in the 1970's, clean coal technologies and advanced scrubbers, and compliance with air quality regulations in 1995 - 2000. The choice of a compliance strategy for many utilities will involve serving customer loads through some combination of scrubbers, clean coal technologies, fuel switching, fuel blending, redispatch of units, and emissions trading. Whatever the final choice, it must be economic while providing sufficient flexibility to accommodate the critical uncertainties of load growth, state regulatory treatment, markets for emission allowances, advancements in control technologies, additional federal requirements for air emissions, equipment outages and fuel supply disruptions.s

  16. Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study.

    Science.gov (United States)

    Gabbay, I E; Bahar, I; Nahum, Y; Livny, E

    2017-08-01

    Descemet's membrane endothelial keratoplasty (DMEK) involves removal of the recipient's Descemet membrane (DM) prior to transplanting the donor's DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host's DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS. We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC. Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p air in the AC contributes to better visualization and an efficient surgery.

  17. The UK National Air Quality Strategy: the effects of the proposed changes on Local Air Quality Management

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, C.I.; Ling, K.; Longhurst, J.W.S. [Univ. of the West of England, Faculty of Applied Sciences, Bristol (GB)] [and others

    1999-07-01

    The UK has implemented a system of Local Air Quality Management (LAQM) to tackle the many contemporary sources of air pollution, notably transport, industry and domestic fuel burning, in a holistic manner. The current legislation stems from the Environment Act 1995, which required a National Air Quality Strategy (NAQS) to be published outlining the Governments policies with respect to the assessment and management of air quality. The NAQS, originally published in March 1997, is on a rolling programme of reviews in order to reflect developments in European legislation, technological and scientific advances, improved air pollution modelling techniques and an increasingly better understanding of the economic and social issues involved. Following the first review (currently at consultation state), this paper will comment on how the proposed changes may affect the LAQM process. The proposed changes will also be summarised and discussed in the context of European Union air quality objectives and the economic analysis of NAQS.

  18. CO2 is in the air. Five myths about the role of air transport in climate changes

    International Nuclear Information System (INIS)

    2015-12-01

    This publication discusses and criticises some general opinions on air transport. Thus, it is often said that air transport is a minor contributor to greenhouse effect (whereas air transport emits as much CO 2 as Germany who is the sixth World emitter, and has various impacts on health), that air transport is doing a lot for the climate (whereas it in fact manages not to be affected by policies against climate change), that more air passengers result in less CO 2 (whereas traffic predictions would result in an increased oil consumption, and increased CO 2 emissions despite promised technological improvements), that technical progress is at the service of climate (whereas the sector is notably late to reach its defined objectives in terms of energy efficiency), and that air transport is the only way to travel (whereas other means emit much less CO 2 ). Some recommendations are made for measures to be adopted at the international, European and French levels for a better protection of the environment

  19. Air Pollution and Industry.

    Science.gov (United States)

    Ross, R. D., Ed.

    This book is an authoritative reference and practical guide designed to help the plant engineer identify and solve industrial air pollution problems in order to be able to meet current air pollution regulations. Prepared under the editorial supervision of an experienced chemical engineer, with each chapter contributed by an expert in his field,…

  20. 29 CFR 1917.155 - Air receivers.

    Science.gov (United States)

    2010-07-01

    .... This section applies to compressed air receivers and equipment used for operations such as cleaning... transportation applications as railways, vehicles or cranes. (b) Gauges and valves. (1) Air receivers shall be... 29 Labor 7 2010-07-01 2010-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...