WorldWideScience

Sample records for kirss eve mgi

  1. Kahevahel : Kui hajusad on kultuuriruumi piirid? / Anna Verschik, Tiina Kirss, Mikko Lagerspetz ; intervjueerinud Daniele Monticelli, Merle Karro-Kalberg

    Index Scriptorium Estoniae

    Verschik, Anna, 1968-

    2015-01-01

    Kultuurist, kultuuriruumist, kultuuris olemisest ja sealt pärinemisest arutlevad TLÜ professori Daniele Monticelli eestvõttel TLÜ professorid Anna Verschik ja Tiina Kirss ning Turu Åbo Akadeemia professor Mikko Lagerspetz

  2. Tartu Ülikooli 86. aastapäeva tähistamine Torontos : "Põhjamaine järjekindlus ja hiinlase kannatus" / Tiina Ann Kirss ; fotod: V. Sarapuu

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2005-01-01

    aktusega Tartu Collegéis 27. novembril 2005. Ülikooli rektor Jaak Aaviksoo analüüsis oma kõnes TÜ arenguvõimalusi ja päevamuresid, Tiina Kirss esitas sissevaate ülikooli ajalukku, muusikalises osas esinesid Kaili ja Riho Maimets

  3. Mouse Genome Informatics (MGI)

    Data.gov (United States)

    U.S. Department of Health & Human Services — MGI is the international database resource for the laboratory mouse, providing integrated genetic, genomic, and biological data to facilitate the study of human...

  4. EVE and School

    CERN Multimedia

    EVE et École

    2017-01-01

    IMPORTANT DATES Enrolments 2017-2018 Enrolments for the school year 2017-2018 to the Nursery, the Kindergarten and the School will take place on 6, 7 and 8 March 2017 from 10 am to 1 pm at EVE and School. Registration forms will be available from Thursday 2nd March. More information on the website: http://nurseryschool.web.cern.ch/. Saturday 4 March 2017 Open day at EVE and School of CERN Staff Association Are you considering enrolling your child to the Children’s Day-Care Centre EVE and School of the CERN Staff Association? If you work at CERN, then this event is for you: come visit the school and meet the Management on Saturday 4 March 2017 from 10 to 12 am We look forward to welcoming you and will be delighted to present our structure, its projects and premises to you, and answer all of your questions. Sign up for one of the two sessions on Doodle via the link below before Wednesday 1st March 2017 : http://doodle.com/poll/gbrz683wuvixk8as

  5. Fuel retention and recovery in natural and MGI disruptions on KSTAR

    International Nuclear Information System (INIS)

    Yu, Y.W.; Hong, S.H.; Yoon, S.W.; Kim, K.P.; Kim, W.C.; Seo, D.C.

    2013-01-01

    Fuel retention and recovery are studied during natural and Massive Gas Injection (MGI) induced disruptions in KSTAR with full graphite wall. The amount of released particles in natural disruptions in 15 s after the discharge is ∼5–10 times higher than that of non-disruption shots, but the difference is only ∼ 2 MGI induced disruptions depends on magnetic field (B t ) and MGI amount. The MGI disruption under a low B t and a medium MGI amount shows shorter thermal quench (TQ) and current quench (CQ), thereby higher fuel recovery. High B t plasma requires higher MGI amount for both disruption mitigation and fuel recovery. A high recovery of 4.2 × 10 22 D (∼0.78 monolayers) is obtained by MGI disruption in KSTAR 2011

  6. MouseMine: a new data warehouse for MGI.

    Science.gov (United States)

    Motenko, H; Neuhauser, S B; O'Keefe, M; Richardson, J E

    2015-08-01

    MouseMine (www.mousemine.org) is a new data warehouse for accessing mouse data from Mouse Genome Informatics (MGI). Based on the InterMine software framework, MouseMine supports powerful query, reporting, and analysis capabilities, the ability to save and combine results from different queries, easy integration into larger workflows, and a comprehensive Web Services layer. Through MouseMine, users can access a significant portion of MGI data in new and useful ways. Importantly, MouseMine is also a member of a growing community of online data resources based on InterMine, including those established by other model organism databases. Adopting common interfaces and collaborating on data representation standards are critical to fostering cross-species data analysis. This paper presents a general introduction to MouseMine, presents examples of its use, and discusses the potential for further integration into the MGI interface.

  7. Overview of EVE - the event visualization environment of ROOT

    International Nuclear Information System (INIS)

    Tadel, Matevz

    2010-01-01

    EVE is a high-level visualization library using ROOT's data-processing, GUI and OpenGL interfaces. It is designed as a framework for object management offering hierarchical data organization, object interaction and visualization via GUI and OpenGL representations. Automatic creation of 2D projected views is also supported. On the other hand, it can serve as an event visualization toolkit satisfying most HEP requirements: visualization of geometry, simulated and reconstructed data such as hits, clusters, tracks and calorimeter information. Special classes are available for visualization of raw-data. Object-interaction layer allows for easy selection and highlighting of objects and their derived representations (projections) across several views (3D, Rho-Z, R-Phi). Object-specific tooltips are provided in both GUI and GL views. The visual-configuration layer of EVE is built around a data-base of template objects that can be applied to specific instances of visualization objects to ensure consistent object presentation. The data-base can be retrieved from a file, edited during the framework operation and stored to file. EVE prototype was developed within the ALICE collaboration and has been included into ROOT in December 2007. Since then all EVE components have reached maturity. EVE is used as the base of AliEve visualization framework in ALICE, Firework physics-oriented event-display in CMS, and as the visualization engine of FairRoot in FAIR.

  8. Overview of EVE - the event visualization environment of ROOT

    Energy Technology Data Exchange (ETDEWEB)

    Tadel, Matevz, E-mail: matevz.tadel@cern.c [CERN, CH-1211 Geneve 23 (Switzerland)

    2010-04-01

    EVE is a high-level visualization library using ROOT's data-processing, GUI and OpenGL interfaces. It is designed as a framework for object management offering hierarchical data organization, object interaction and visualization via GUI and OpenGL representations. Automatic creation of 2D projected views is also supported. On the other hand, it can serve as an event visualization toolkit satisfying most HEP requirements: visualization of geometry, simulated and reconstructed data such as hits, clusters, tracks and calorimeter information. Special classes are available for visualization of raw-data. Object-interaction layer allows for easy selection and highlighting of objects and their derived representations (projections) across several views (3D, Rho-Z, R-Phi). Object-specific tooltips are provided in both GUI and GL views. The visual-configuration layer of EVE is built around a data-base of template objects that can be applied to specific instances of visualization objects to ensure consistent object presentation. The data-base can be retrieved from a file, edited during the framework operation and stored to file. EVE prototype was developed within the ALICE collaboration and has been included into ROOT in December 2007. Since then all EVE components have reached maturity. EVE is used as the base of AliEve visualization framework in ALICE, Firework physics-oriented event-display in CMS, and as the visualization engine of FairRoot in FAIR.

  9. The radiation asymmetry in MGI rapid shutdown on J-TEXT tokamak

    Science.gov (United States)

    Tong, Ruihai; Chen, Zhongyong; Huang, Duwei; Cheng, Zhifeng; Zhang, Xiaolong; Zhuang, Ge; J-TEXT Team

    2017-10-01

    Disruptions, the sudden termination of tokamak fusion plasmas by instabilities, have the potential to cause severe material wall damage to large tokamaks like ITER. The mitigation of disruption damage is an essential part of any fusion reactor system. Massive gas injection (MGI) rapid shutdown is a technique in which large amounts of noble gas are injected into the plasma in order to safely radiate the plasma energy evenly over the entire plasma-facing first wall. However, the radiated energy during the thermal quench (TQ) in massive gas injection (MGI) induced disruptions is found toroidal asymmetric, and the degrees of asymmetry correlate with the gas penetration and MGI induced magnetohydrodynamics (MHD) activities. A toroidal and poloidal array of ultraviolet photodiodes (AXUV) has been developed to investigate the radiation asymmetry on J-TEXT tokamak. Together with the upgraded mirnov probe arrays, the relation between MGI triggered MHD activities with radiation asymmetry is studied.

  10. Mouse Genome Informatics (MGI) Resource: Genetic, Genomic, and Biological Knowledgebase for the Laboratory Mouse.

    Science.gov (United States)

    Eppig, Janan T

    2017-07-01

    The Mouse Genome Informatics (MGI) Resource supports basic, translational, and computational research by providing high-quality, integrated data on the genetics, genomics, and biology of the laboratory mouse. MGI serves a strategic role for the scientific community in facilitating biomedical, experimental, and computational studies investigating the genetics and processes of diseases and enabling the development and testing of new disease models and therapeutic interventions. This review describes the nexus of the body of growing genetic and biological data and the advances in computer technology in the late 1980s, including the World Wide Web, that together launched the beginnings of MGI. MGI develops and maintains a gold-standard resource that reflects the current state of knowledge, provides semantic and contextual data integration that fosters hypothesis testing, continually develops new and improved tools for searching and analysis, and partners with the scientific community to assure research data needs are met. Here we describe one slice of MGI relating to the development of community-wide large-scale mutagenesis and phenotyping projects and introduce ways to access and use these MGI data. References and links to additional MGI aspects are provided. © The Author 2017. Published by Oxford University Press.

  11. gEVE: a genome-based endogenous viral element database provides comprehensive viral protein-coding sequences in mammalian genomes.

    Science.gov (United States)

    Nakagawa, So; Takahashi, Mahoko Ueda

    2016-01-01

    In mammals, approximately 10% of genome sequences correspond to endogenous viral elements (EVEs), which are derived from ancient viral infections of germ cells. Although most EVEs have been inactivated, some open reading frames (ORFs) of EVEs obtained functions in the hosts. However, EVE ORFs usually remain unannotated in the genomes, and no databases are available for EVE ORFs. To investigate the function and evolution of EVEs in mammalian genomes, we developed EVE ORF databases for 20 genomes of 19 mammalian species. A total of 736,771 non-overlapping EVE ORFs were identified and archived in a database named gEVE (http://geve.med.u-tokai.ac.jp). The gEVE database provides nucleotide and amino acid sequences, genomic loci and functional annotations of EVE ORFs for all 20 genomes. In analyzing RNA-seq data with the gEVE database, we successfully identified the expressed EVE genes, suggesting that the gEVE database facilitates studies of the genomic analyses of various mammalian species.Database URL: http://geve.med.u-tokai.ac.jp. © The Author(s) 2016. Published by Oxford University Press.

  12. 76 FR 81827 - Safety Zone; Sacramento New Years Eve Fireworks Display, Sacramento, CA

    Science.gov (United States)

    2011-12-29

    ... Zone; Sacramento New Years Eve Fireworks Display, Sacramento, CA AGENCY: Coast Guard, DHS. ACTION... during the Sacramento New Years Eve Fireworks Display in the navigable waters of the Sacramento River... Sacramento New Years Eve Fireworks Display safety zones in the navigable waters of the Sacramento River near...

  13. EVE et École

    CERN Multimedia

    Staff Association

    2017-01-01

    Il reste des places disponibles ! La structure Espace de vie enfantine (EVE) et École de l’Association du personnel du CERN vous informe qu’il reste quelques places pour la rentrée scolaire 2017-2018 : à la crèche (2-3 ans) (accueil sur 2, 3 ou 5 jours) ; au jardin d’enfants (2-4 ans) (accueil à la matinée) ; en classe de 1ère primaire (1P) (4-5 ans). N’hésitez pas à rapidement nous contacter si vous êtes intéressés ; nous sommes à votre disposition pour répondre à toutes vos questions : Staff.Kindergarten@cern.ch. L’EVE et École de l’Association du personnel du CERN est ouverte non seulement aux enfants des personnels du CERN (MPE, MPA) mais également aux enfants des personnes ne travaillant pas sur le domaine du CERN. ...

  14. EVE et École

    CERN Multimedia

    Staff Association

    2017-01-01

    Une belle fête de fin d’année Le vendredi 23 juin, il y avait foule dans la structure EVE et École de l’Association du personnel du CERN! Et pour cause, au programme de cette fin d’après-midi : de nombreuses animations et jeux variés proposés pour le plaisir des enfants et des parents ; une fête en plein air, dans la cour de l’école et le jardin, avec des jeux, des stands, une buvette. Les frites et saucisses ont été préparées par l’équipe de l’EVE et École, qui portait des t-shirts fluo, en référence au thème de l’année: les couleurs. Plusieurs stands étaient proposés comme par exemple, un coin maquillage ; avec ces artistes maquilleurs, les enfants sont devenus lion, papillon ou coccinelle, l’histoire de quelques...

  15. Moekunstnik Eve Hanson: hindan häid traditsioone ja innovaatilisust / Eve Hanson ; intervjueerinud Tanel Veenre

    Index Scriptorium Estoniae

    Hanson, Eve

    2009-01-01

    Peadisainer Eve Hanson 1994. aastal loodud moemärgist Ivo Nikkolo. Näitus "Ivo Nikkolo 15 - julgus olla IN" Baltika kvartalis 29. nov.-ni. Eksponeeritud ka Ivo Nikkolo erikollektsioon "One in a hundred"

  16. Effects of spin-orbit coupling on laser cooling of BeI and MgI

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Mingjie, E-mail: wanmingjie1983@sina.com; Huang, Duohui; Shao, Juxiang; Li, Yuanyuan [Computational Physics Key Laboratory of Sichuan Province, Yibin University, Yibin 644007 (China); Yu, You [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu 610225 (China); Li, Song [College of Physical Science and Technology, Yangtze University, Jingzhou 434023 (China)

    2015-10-28

    We present the ab initio study of spin-orbit coupling effects on laser cooling of BeI and MgI molecules. Potential energy curves for the X{sup 2}Σ{sup +}{sub 1/2}, A{sup 2}Π{sub 1/2,3/2}, and 2{sup 2}Π{sub 3/2,1/2} states are calculated using multi-reference configuration interaction method plus Davidson corrections. Spectroscopic parameters of BeI and MgI are in excellent agreement with available experimental and theoretical values. The A{sup 2}Π{sub 3/2} state of MgI is a repulsive state. It is an unsuitable scheme for the A{sup 2}Π{sub 3/2}(υ′)← X{sup 2}Σ{sup +}{sub 1/2} (υ″) transition for laser cooling of MgI. Highly diagonally distributed Franck-Condon factors f{sub 00} for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) ← X{sup 2}Σ{sup +}{sub 1/2} (υ″ = 0) transitions and suitable radiative lifetimes τ for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) of BeI and MgI are obtained. Three laser wavelength drives are required for the A{sup 2}Π{sub 1/2,3/2}(υ′)←X{sup 2}Σ{sup +}{sub 1/2} (υ″) transitions of BeI and MgI. The proposed cooling wavelengths of BeI and MgI are both in the violet region. The results imply the feasibility of laser cooling of BeI and MgI, and that laser cooling of BeI is more possible.

  17. Lines of MgI Detected in Solar Prominences

    Czech Academy of Sciences Publication Activity Database

    Heinzel, Petr; Kupryakov, Yu. A.; Schwartz, P.

    2016-01-01

    Roč. 40, č. 1 (2016), s. 87-91 ISSN 1845-8319. [Hvar Astrophysical Colloquium /14./. Hvar, 26.09.2016-30.09.2016] Institutional support: RVO:67985815 Keywords : prominences * limb-flare * MgI emession Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  18. EVE and School - Enrolments

    CERN Multimedia

    EVE et École

    2017-01-01

    IMPORTANT DATES Enrolments 2017-2018 Enrolments for the school year 2017-2018 to the Nursery, the Kindergarten and the School will take place on 6, 7 and 8 March 2017 from 10 am to 1 pm at EVE and School. Registration forms will be available from Thursday 2nd March. More information on the website: http://nurseryschool.web.cern.ch/.

  19. Genome-wide analysis of EgEVE_1, a transcriptionally active endogenous viral element associated to small RNAs in Eucalyptus genomes

    Directory of Open Access Journals (Sweden)

    Helena Sanches Marcon

    2017-02-01

    Full Text Available Abstract Endogenous viral elements (EVEs are the result of heritable horizontal gene transfer from viruses to hosts. In the last years, several EVE integration events were reported in plants by the exponential availability of sequenced genomes. Eucalyptus grandis is a forest tree species with a sequenced genome that is poorly studied in terms of evolution and mobile genetic elements composition. Here we report the characterization of E. grandis endogenous viral element 1 (EgEVE_1, a transcriptionally active EVE with a size of 5,664 bp. Phylogenetic analysis and genomic distribution demonstrated that EgEVE_1 is a newly described member of the Caulimoviridae family, distinct from the recently characterized plant Florendoviruses. Genomic distribution of EgEVE_1 and Florendovirus is also distinct. EgEVE_1 qPCR quantification in Eucalyptus urophylla suggests that this genome has more EgEVE_1 copies than E. grandis. EgEVE_1 transcriptional activity was demonstrated by RT-qPCR in five Eucalyptus species and one intrageneric hybrid. We also identified that Eucalyptus EVEs can generate small RNAs (sRNAs,that might be involved in de novo DNA methylation and virus resistance. Our data suggest that EVE families in Eucalyptus have distinct properties, and we provide the first comparative analysis of EVEs in Eucalyptus genomes.

  20. Mouse Genome Informatics (MGI) Is the International Resource for Information on the Laboratory Mouse.

    Science.gov (United States)

    Law, MeiYee; Shaw, David R

    2018-01-01

    Mouse Genome Informatics (MGI, http://www.informatics.jax.org/ ) web resources provide free access to meticulously curated information about the laboratory mouse. MGI's primary goal is to help researchers investigate the genetic foundations of human diseases by translating information from mouse phenotypes and disease models studies to human systems. MGI provides comprehensive phenotypes for over 50,000 mutant alleles in mice and provides experimental model descriptions for over 1500 human diseases. Curated data from scientific publications are integrated with those from high-throughput phenotyping and gene expression centers. Data are standardized using defined, hierarchical vocabularies such as the Mammalian Phenotype (MP) Ontology, Mouse Developmental Anatomy and the Gene Ontologies (GO). This chapter introduces you to Gene and Allele Detail pages and provides step-by-step instructions for simple searches and those that take advantage of the breadth of MGI data integration.

  1. Multi-MGy Radiation Hardened Camera for Nuclear Facilities

    International Nuclear Information System (INIS)

    Girard, Sylvain; Boukenter, Aziz; Ouerdane, Youcef; Goiffon, Vincent; Corbiere, Franck; Rolando, Sebastien; Molina, Romain; Estribeau, Magali; Avon, Barbara; Magnan, Pierre; Paillet, Philippe; Duhamel, Olivier; Gaillardin, Marc; Raine, Melanie

    2015-01-01

    There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO 2 ) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera

  2. Multi-MGy Radiation Hardened Camera for Nuclear Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Girard, Sylvain; Boukenter, Aziz; Ouerdane, Youcef [Universite de Saint-Etienne, Lab. Hubert Curien, UMR-CNRS 5516, F-42000 Saint-Etienne (France); Goiffon, Vincent; Corbiere, Franck; Rolando, Sebastien; Molina, Romain; Estribeau, Magali; Avon, Barbara; Magnan, Pierre [ISAE, Universite de Toulouse, F-31055 Toulouse (France); Paillet, Philippe; Duhamel, Olivier; Gaillardin, Marc; Raine, Melanie [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-07-01

    There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera

  3. Sügismoes seguneb klassika vimkadega / Eve Rohtla

    Index Scriptorium Estoniae

    Rohtla, Eve, 1961-

    2003-01-01

    Ivo Nikkolo kaubamärki kandvat sügis-talvist kollektsiooni esitleti lioni'te naisteklubi salongiõhtul Viljandis. Disainer Eve Hanson kollektsiooni moeknihvidest. Ivo Nikkolo kollektsiooni disainib, toodab ja turustab osaühing Zik Zak

  4. Microstructural evolution during dry wear test in magnesium and Mg-Y alloy

    Energy Technology Data Exchange (ETDEWEB)

    Somekawa, Hidetoshi, E-mail: SOMEKAWA.Hidetoshi@nims.go.jp [Research Center for Strategic Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Maeda, Shunsuke; Hirayama, Tomoko; Matsuoka, Takashi [Department of Mechanical Engineering, Doshisha University, 1-3 Miyakodani, Tatara, Kyotanabe 610-0321 (Japan); Inoue, Tadanobu [Research Center for Strategic Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Mukai, Toshiji [Department of Mechanical Engineering, Kobe University, 1-1 Rokkodai, Kobe, 657-8501 (Japan)

    2013-01-20

    The friction and wear properties of pure magnesium and the Mg-Y alloy were investigated using the pin-on-disk configuration. The friction and wear resistance of the Mg-Y alloy was superior to those of pure magnesium. The wear mechanism was abrasion under all the conditions. The deformed microstructural evolutions near the surface region were observed by transmission electron microscopy and electron backscatter diffraction. The stress and strain states were also evaluated by finite element analysis (FEA). The deformed microstructures of both alloys consisted of the {l_brace}10-12{r_brace} twinning formation and the FEA results showed the occurrence of plastic deformation even at the beginning of the test. The formation of low angle grain boundaries was also confirmed with an increase in the applied load in the Mg-Y alloy. On the other hand, grain refinement due to dynamic recrystallization was observed in pure magnesium as the wear test progressed. The different microstructures resulted from difference in the surface temperature during the wear test, which was estimated to be around 393 K and 363 K for pure magnesium and the Mg-Y alloy, respectively. The high increment temperature in the fine-grained alloys brought about the occurrence of grain boundary sliding, i.e., material softening, which led to a decrease in the friction and wear properties. The present results indicated that one of the methods for enhancing the friction and wear properties is to increase the dynamic recrystallization temperature.

  5. EVE and School: Important announcement

    CERN Multimedia

    Staff Association

    2017-01-01

    Children’s Day-Care Centre (EVE) and School of the CERN Staff Association would like to inform you that there are still a few places available within the structure for the school year 2017–2018, in the: Nursery for 2, 3 or 5 days a week (2- to 3-year-olds); Kindergarten for mornings (2- to 4-year-olds); Primary 1 (1p) class in the School (4- to 5-year-olds). Please get in touch with us quickly if you are interested in any of the available places. We will gladly provide further information and answer any questions you may have: Staff.Kindergarten@cern.ch or (+41) 022 767 36 04 (mornings). EVE and School of the CERN Staff Association welcomes children of CERN Members of Personnel (MPE, MPA), as well as children whose parents do not work on CERN site. We would like to remind you that registrations are also open for the Summer Camp. The camp will run through the four weeks of July from 8.30 am to 5.30 pm with a weekly registration for 450 CHF, lunch included. For more information and regist...

  6. The p-EVES study design and methodology: a randomised controlled trial to compare portable electronic vision enhancement systems (p-EVES) to optical magnifiers for near vision activities in visual impairment.

    Science.gov (United States)

    Taylor, John; Bambrick, Rachel; Dutton, Michelle; Harper, Robert; Ryan, Barbara; Tudor-Edwards, Rhiannon; Waterman, Heather; Whitaker, Chris; Dickinson, Chris

    2014-09-01

    To describe the study design and methodology for the p-EVES study, a trial designed to determine the effectiveness, cost-effectiveness and acceptability of portable Electronic Vision Enhancement System (p-EVES) devices and conventional optical low vision aids (LVAs) for near tasks in people with low vision. The p-EVES study is a prospective two-arm randomised cross-over trial to test the hypothesis that, in comparison to optical LVAs, p-EVES can be: used for longer duration; used for a wider range of tasks than a single optical LVA and/or enable users to do tasks that they were not able to do with optical LVAs; allow faster performance of instrumental activities of daily living; and allow faster reading. A total of 100 adult participants with visual impairment are currently being recruited from Manchester Royal Eye Hospital and randomised into either Group 1 (receiving the two interventions A and B in the order AB), or Group 2 (receiving the two interventions in the order BA). Intervention A is a 2-month period with conventional optical LVAs and a p-EVES device, and intervention B is a 2-month period with conventional optical LVAs only. The study adopts a mixed methods approach encompassing a broad range of outcome measures. The results will be obtained from the following primary outcome measures: Manchester Low Vision Questionnaire, capturing device 'usage' data (which devices are used, number of times, for what purposes, and for how long) and the MNRead test, measuring threshold print size, critical print size, and acuity reserve in addition to reading speed at high (≈90%) contrast. Results will also be obtained from a series of secondary outcome measures which include: assessment of timed instrumental activities of daily living and a 'near vision' visual functioning questionnaire. A companion qualitative study will permit comparison of results on how, where, and under what circumstances, p-EVES devices and LVAs are used in daily life. A health economic

  7. Gender Ideology in The Diary Of Adam And Eve by Mark Twain

    Directory of Open Access Journals (Sweden)

    Paramita Ayuningtyas

    2011-04-01

    Full Text Available This article aims to show that behind the new version of Genesis by Mark Twain in his novel The Diary of Adam and Eve, there are some patriarchal principles that appear in it. It can be seen from the characterizations of Adam and Eve. By using some concepts from feminism and also focusing on the context of the novel, the analysis shows that patriarchal stereotypes about gender are applied in constructing the characters of Adam and Eve. Not only the content, but the form of the diary is also analyzed with the same method, and the same result is found. Therefore, it can be concluded that in spite of his progressiveness, Mark Twain still held patriarchal values in re-interpreting the tale of human creation.   

  8. EPO for the NASA SDO Extreme Ultraviolet Variability Experiment (EVE) Learning Suite for Educators

    Science.gov (United States)

    Kellagher, Emily; Scherrer, D. K.

    2013-07-01

    EVE Education and Public Outreach (EPO) promotes an understanding of the process of science and concepts within solar science and sun-earth connections. EVE EPO also features working scientists, current research and career awareness. One of the highlights for of this years projects is the digitization of solar lessons and the collaboration with the other instrument teams to develop new resources for students and educators. Digital lesson suite: EVE EPO has taken the best solar lessons and reworked then to make then more engaging, to reflect SDO data and made them SMARTboard compatible. We are creating a website that Students and teachers can access these lesson and use them online or download them. Project team collaboration: The SDO instruments (EVE, AIA and HMI) teams have created a comic book series for upper elementary and middle school students with the SDO mascot Camilla. These comics may be printed or read on mobile devices. Many teachers are looking for resources to use with their students via the Ipad so our collaboration helps supply teachers with a great resource that teachers about solar concepts and helps dispel solar misconceptions.Abstract (2,250 Maximum Characters): EVE Education and Public Outreach (EPO) promotes an understanding of the process of science and concepts within solar science and sun-earth connections. EVE EPO also features working scientists, current research and career awareness. One of the highlights for of this years projects is the digitization of solar lessons and the collaboration with the other instrument teams to develop new resources for students and educators. Digital lesson suite: EVE EPO has taken the best solar lessons and reworked then to make then more engaging, to reflect SDO data and made them SMARTboard compatible. We are creating a website that Students and teachers can access these lesson and use them online or download them. Project team collaboration: The SDO instruments (EVE, AIA and HMI) teams have created a

  9. Klaasikunstisügis Baltikumis / Eve Koha

    Index Scriptorium Estoniae

    Koha, Eve

    2002-01-01

    11. X-15. XI Kaunase raekojas M. K. Ciurlionise nim. rahvusliku kunsti muuseumi keraamika muuseumis rahvusvahelisel klaasikunsti biennaalil "Vitrum Balticum II" osalevad Eestist Eve Koha, Ivo Lill, Mare Saare. Albinas Elskusest, Mark Eckstrandist. 20. X-20. XI Riia vanalinna klaasigaleriis Laipu t. 6 eesti ja läti klaasikunstnike ühisnäitusel, kus tutvustatakse vanu klaasitehnikaid ja vanade klaasiahjude ehitust, osalevad Eestist Kati Kerstna, Merle Hiis

  10. The Lawless Frontier of Deep Space: Code as Law in EVE Online

    Directory of Open Access Journals (Sweden)

    Melissa de Zwart

    2014-03-01

    Full Text Available This article explores the concepts of player agency with respect to governance and regulation of online games. It considers the unique example of the Council of Stellar Management in EVE Online, and explores the multifaceted role performed by players involved in that Council. In particular, it considers the interaction between code, rules, contracts, and play with respect to EVE Online. This is used as a means to better understand the relations of power generated in game spaces.

  11. 77 FR 75556 - Safety Zone; Sacramento New Year's Eve Fireworks Display, Sacramento River, Sacramento, CA

    Science.gov (United States)

    2012-12-21

    ... Zone; Sacramento New Year's Eve Fireworks Display, Sacramento River, Sacramento, CA AGENCY: Coast Guard... safety zones during the Sacramento New Year's Eve Fireworks Display in the navigable waters of the Sacramento River on December 31, 2012 and January 1, 2013. The fireworks displays will occur from 9 p.m. to 9...

  12. An Innovative Aperture Cover Mechanism Used on SDO/EVE and MMS/SDP

    Science.gov (United States)

    Steg, Stephen; Vermeer, William; Tucker, Scott; Passe, Heather

    2014-01-01

    This paper describes an aperture cover mechanism that was successfully flown in four locations on SDO/EVE, and is awaiting launch in sixteen locations on MMS. This design uses a paraffin actuator and a latch that secures the cover closed and removes the actuator from the load path. This latch allows the assembly to operate both as a light weight contamination cover (SDO/EVE), and also as a high-strength sensor restraint mechanism (MMS/SDP). The paper provides design/analysis/test information about the mechanism.

  13. The Adam and Eve Robot Scientists for the Automated Discovery of Scientific Knowledge

    Science.gov (United States)

    King, Ross

    A Robot Scientist is a physically implemented robotic system that applies techniques from artificial intelligence to execute cycles of automated scientific experimentation. A Robot Scientist can automatically execute cycles of hypothesis formation, selection of efficient experiments to discriminate between hypotheses, execution of experiments using laboratory automation equipment, and analysis of results. The motivation for developing Robot Scientists is to better understand science, and to make scientific research more efficient. The Robot Scientist `Adam' was the first machine to autonomously discover scientific knowledge: both form and experimentally confirm novel hypotheses. Adam worked in the domain of yeast functional genomics. The Robot Scientist `Eve' was originally developed to automate early-stage drug development, with specific application to neglected tropical disease such as malaria, African sleeping sickness, etc. We are now adapting Eve to work with on cancer. We are also teaching Eve to autonomously extract information from the scientific literature.

  14. Percolation Model for the Existence of a Mitochondrial Eve

    CERN Document Server

    Neves, A G M

    2005-01-01

    We look at the process of inheritance of mitochondrial DNA as a percolation model on trees equivalent to the Galton-Watson process. The model is exactly solvable for its percolation threshold $p_c$ and percolation probability critical exponent. In the approximation of small percolation probability, and assuming limited progeny number, we are also able to find the maximum and minimum percolation probabilities over all probability distributions for the progeny number constrained to a given $p_c$. As a consequence, we can relate existence of a mitochondrial Eve to quantitative knowledge about demographic evolution of early mankind. In particular, we show that a mitochondrial Eve may exist even in an exponentially growing population, provided that the average number of children per individual is constrained to a small range depending on the probability $p$ that a newborn child is a female.

  15. Uus korter ja midagi veel / Eve Kaunis

    Index Scriptorium Estoniae

    Kaunis, Eve

    2008-01-01

    Uus Maa kinnisvarabüroo eluruumide konsultant Eve Kaunis ostjate eelistustest korterite valikul. Peamised müügiargumendid on soodne hind ja rohked lisaväärtused. Näiteks toodud 2-toaline korter (sisekujundus: Aet Piel, 71 m2) Põhja-Tallinnas Eugen Sachariase projekti järgi ehitatud majas ja 3-toaline korter (66,4 m2) Keilas 1980. aastatel ehitatud elamus

  16. The influence of yttrium (Y) on the corrosion of Mg-Y binary alloys

    International Nuclear Information System (INIS)

    Liu Ming; Schmutz, Patrik; Uggowitzer, Peter J.; Song Guangling; Atrens, Andrej

    2010-01-01

    Research highlights: → The Y-intermetallic can accelerate corrosion and Y can increase the protectiveness of the surface layer. → In 0.1 M NaCl, the corrosion rate of Mg-Y alloys increased with increasing Y due to the Y intermetallic. → In 0.1 M NaCl, there was filiform corrosion. → In 0.1 M Na 2 SO 4 , the corrosion rate of Mg-Y alloys decreased with increasing Y in the range 3-7%Y. → Hydrogen evolution was observed from particular parts of the alloy surface. - Abstract: Corrosion of Mg-Y alloys was studied using electrochemical evaluations, immersion tests and direct observations. There were two important effects. In 0.1 M NaCl, the corrosion rate increased with increasing Y content due to increasing amounts of the Y-containing intermetallic. In 0.1 M Na 2 SO 4 , the corrosion rate decreased with increasing Y content above 3%, attributed to a more protective surface film, despite the intermetallic. The corrosion rate evaluated by electrochemical impedance spectroscopy was somewhat smaller than that evaluated from H evolution as expected from the Mg corrosion mechanism. A mechanism is proposed for filiform corrosion. Direct in situ corrosion observations revealed that a predominant feature was hydrogen evolution from particular parts of the alloy surface.

  17. Eve or Evolution? The Question of the Creation of Adam and Eve as the First Humans versus the Theory That Humankind Evolved Over The Course of Millions of Years

    Directory of Open Access Journals (Sweden)

    Eloise T. Choice

    2016-11-01

    Full Text Available Inherent in the Creation (“Intelligent Design” versus the Theory of Evolution (“natural selection” War, is the scientific belief in the millennia-long “evolution” of humankind, versus the Christian belief in the creation of the Biblical Adam and Eve circa 7,700 B.C. This article shows that there is no such thing as an “evolution” of Earth’s life forms. Over the course of millions of years, God created then, re-designed all Earth’s life forms in successive stages, which accounts for the non-linear progression of said forms and particularly of humanoids. Integrating Mitochondria DNA and archaeological evidence with Judeo-Christian and extra-Biblical texts, shows that after God created then re-designed pre-Adamic humans, He created the Biblical Adam and Eve circa 9,700 years ago during the Mesolithic Period as prototypes for present-day man. Moreover, archaeological evidence, plus Judeo-Christian and extra-Biblical texts suggest that Eve and Adam co-existed with Homo sapiens during the Mesolithic/Neolithic Periods.

  18. 78 FR 77359 - Eighth Coast Guard District Annual Safety Zones; New Year's Eve Celebration/City of Mobile...

    Science.gov (United States)

    2013-12-23

    ...-AA00 Eighth Coast Guard District Annual Safety Zones; New Year's Eve Celebration/City of Mobile; Mobile Channel; Mobile, AL AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard will enforce the City of Mobile New Year's Eve Celebration safety zone in the Mobile Channel, Mobile, AL from...

  19. Eve and the Madonna in Victorian Art

    OpenAIRE

    Dungan, Bebhinn

    2012-01-01

    Full version unavailable due to 3rd party copyright restrictions. Full version unavailable due to 3rd party copyright restrictions. Full version unavailable due to 3rd party copyright restrictions. Full version unavailable due to 3rd party copyright restrictions. Full version unavailable due to 3rd party copyright restrictions. Abstract This study identifies and addresses representations of Eve and the Madonna exhibited at seven well-known London venues during the Victorian...

  20. Tantsija Eve Mutso jäi Londonis silma / Stuart Sweeney

    Index Scriptorium Estoniae

    Sweeney, Stuart

    2006-01-01

    Londonis andis märtsis külalisetendusi Šoti ballett, kus solistina esines juba aastaid Shoti balletis tantsiv eestlanna Eve Mutso. Ta astus üles Ashley Page'i balletis "Tuhkatriinu", samuti ühe juhtivsolistina George Balanchine'i "Episoodides" ja William Forsythe'i "Süidis artefaktist"

  1. Milton’s Pro-Feminist Presentation of Eve in Paradise Lost

    Directory of Open Access Journals (Sweden)

    Abdullah F. Al-Badarneh

    2014-07-01

    Full Text Available This paper absolves John Milton from any critical and feminist accusation of being anti-feminist in Paradise Lost. Such defense of Milton is based on the close reading and analysis of the passages that focus on Adam and Eve in the text. This study highlights Milton’s modern view of women as independent, free, and responsible. It also presents his iconoclasm in representing women as leaders and initiative takers when decision is to be taken. This study shows Milton reversing traditional gender roles through the relationship of Adam and Eve. In addition, one can find a modern emphasis on the principles of equality, democracy, dialogue, freedom, and free will available in the poem and designed in a way that serves Eve’s rights in comparison with Adam’s. Therefore, my voice in defending Milton joins the cohort of critics who believe of Milton’s wide perspective of pro-feminism and not a person of misogyny.

  2. Overview of EVE – the event visualization environment of ROOT

    CERN Document Server

    Tadel, M

    2010-01-01

    EVE is a high-level visualization library using ROOT's data-processing, GUI and OpenGL interfaces. It is designed as a framework for object management offering hierarchical data organization, object interaction and visualization via GUI and OpenGL representations. Automatic creation of 2D projected views is also supported. On the other hand, it can serve as an event visualization toolkit satisfying most HEP requirements: visualization of geometry, simulated and reconstructed data such as hits, clusters, tracks and calorimeter information. Special classes are available for visualization of raw-data. Object-interaction layer allows for easy selection and highlighting of objects and their derived representations (projections) across several views (3D, Rho-Z, R-Phi). Object-specific tooltips are provided in both GUI and GL views. The visual-configuration layer of EVE is built around a data-base of template objects that can be applied to specific instances of visualization objects to ensure consistent object prese...

  3. A MGy radiation-hardened sensor instrumentation link for nuclear reactor monitoring and remote handling

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens; Cao, Ying [KU Leuven - KUL, Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Van Uffelen, Marco; Mont Casellas, Laura; Damiani, Carlo; Morales, Emilio Ruiz; Santana, Roberto Ranz [Fusion for Energy - F4E, c/Josep,n deg. 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Meek, Richard; Haist, Bernhard [Oxford Technologies Ltd. OTL, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); De Cock, Wouter; Vermeeren, Ludo [SCK-CEN, Boeretang 200, 2400 Mol (Belgium); Steyaert, Michiel [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium)

    2015-07-01

    Decommissioning, dismantling and remote handling applications in nuclear facilities all require robotic solutions that are able to survive in radiation environments. Recently raised safety, radiation hardness and cost efficiency demands from both the nuclear regulatory and the society impose severe challenges in traditional methods. For example, in case of the dismantling of the Fukushima sites, solutions that survive accumulated doses higher than 1 MGy are mandatory. To allow remote operation of these tools in nuclear environments, electronics were used to be shielded with several centimeters of lead or even completely banned in these solutions. However, shielding electronics always leads to bulky and heavy solutions, which reduces the flexibility of robotic tools. It also requires longer repair time and produces extra waste further in a dismantling or decommissioning cycle. In addition, often in current reactor designs, due to size restrictions and the need to inspect very tight areas there are limitations to the use of shielding. A MGy radiation-hardened sensor instrumentation link developed by MAGyICS provides a solution to build a flexible, easy removable and small I and C module with MGy radiation tolerance without any shielding. Hereby it removes all these pains to implement electronics in robotic tools. The demonstrated solution in this poster is developed for ITER Remote Handling equipments operating in high radiation environments (>1 MGy) in and around the Tokamak. In order to obtain adequately accurate instrumentation and control information, as well as to ease the umbilical management, there is a need of front-end electronics that will have to be located close to those actuators and sensors on the remote handling tool. In particular, for diverter remote handling, it is estimated that these components will face gamma radiation up to 300 Gy/h (in-vessel) and a total dose of 1 MGy. The radiation-hardened sensor instrumentation link presented here, consists

  4. EVE: Explainable Vector Based Embedding Technique Using Wikipedia

    OpenAIRE

    Qureshi, M. Atif; Greene, Derek

    2017-01-01

    We present an unsupervised explainable word embedding technique, called EVE, which is built upon the structure of Wikipedia. The proposed model defines the dimensions of a semantic vector representing a word using human-readable labels, thereby it readily interpretable. Specifically, each vector is constructed using the Wikipedia category graph structure together with the Wikipedia article link structure. To test the effectiveness of the proposed word embedding model, we consider its usefulne...

  5. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L. [CEA, DAM, DIF, F-91297 Arpajon (France); Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P. [ISAE, Universite de Toulouse, 10 avenue Edouard Belin, BP 54032, 31055 Toulouse Cedex 4 (France); Girard, S.; Ouerdane, Y.; Boukenter, A. [Universite de Saint-Etienne, Laboratoire H. Curien, UMR-5516, 42000, Saint-Etienne (France)

    2015-07-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  6. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L.; Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P.; Girard, S.; Ouerdane, Y.; Boukenter, A.

    2015-01-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  7. Simulation of MGI efficiency for plasma energy conversion into Ar radiation in JET and implications for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Pestchanyi, Serguei, E-mail: serguei.pestchanyi@kit.edu [Association EURATOM-KIT, Karlsruhe (Germany); Koslowski, Rudi; Reux, Cedric [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Lehnen, Michael [Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • We simulated disruption mitigation using massive gas injection with the TOKES code. • Cross-reference analysis of JET experiments on MGI and their simulations have been done. • The analysis allows suggesting the mechanism for saturation of radiated energy fraction at 70–80%. • Rough extrapolation of the result on ITER conditions has been done. - Abstract: Effectiveness of massive gas injection (MGI) for mitigation of disruptive wall damage has been investigated. Cross-reference analysis of the available JET experiments on MGI and their simulations with the TOKES code allow suggesting that in JET conditions one can convert into radiation the electron thermal energy and the plasma current energy, but the ion thermal energy does not convert into radiation because of very ineffective excitation of injected noble gas (NG) ions by D ions and long equipartition time between D ions and electrons. The model assumes rather high electron temperature during current quench (CQ), which contradicts with its time duration. Rough extrapolation of the result on ITER conditions shows that one can expect irradiation of total plasma energy if CQ duration in ITER is not shorter as in JET.

  8. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  9. HUBUNGAN CITRA MERK BUS (MGI) DENGAN KEPUASAN KONSUMEN PADA TRAYEK BANDUNG-SUKABUMI

    OpenAIRE

    Ulfa Chairunnisa

    2018-01-01

    This research aims to study correlation between brand image and customer satisfaction. Quantitative design using correlational method involved 350 MGI bus customer in Bandung-Sukabumi route. Instruments used are Brand Image Inventory (37 item) and Customer Satisfaction Index (37 item). Cooeficient  correlation resulted is 0.684 which means that there is positive correlation between brand image and customer satisfction. High brand image correlated with high customer satisfaction while low bran...

  10. Extent, nature and hospital costs of fireworks-related injuries during the Wednesday Eve festival in Iran.

    Science.gov (United States)

    Alinia, Siros; Rezaei, Satar; Daroudi, Rajabali; Hadadi, Mashyaneh; Akbari Sari, Ali

    2013-01-01

    Fireworks are commonly used in local and national celebrations. The aim of this study is to explore the extent, nature and hospital costs of injuries related to the Persian Wednesday Eve festival in Iran. Data for injuries caused by fireworks during the 2009 Persian Wednesday Eve festival were collected from the national Ministry of Health database. Injuries were divided into nine groups and the average and total hospital costs were estimated for each group. The cost of care for patients with burns was estimated by reviewing a sample of 100 patients randomly selected from a large burn center in Tehran. Other costs were estimated by conducting semi structured interviews with expert managers at two large government hospitals. 1817 people were injured by fireworks during the 2009 Wednesday Eve festival. The most frequently injured sites were the hand (43.3%), eye (24.5%) and face (13.2%), and the most common types of injury were burns (39.9%), contusions/abrasions (24.6%) and lacerations (12.7%). The mean length of hospital stay was 8.15 days for patients with burns, 10.7 days for those with amputations, and 3 days for those with other types of injury. The total hospital cost of injuries was US$ 284 000 and the average cost per injury was US$ 156. The total hospital cost of patients with amputations was US$ 48 598. Most of the costs were related to burns (56.6%) followed by amputations (12.2%). Injuries related to the Persian Wednesday Eve festival are common and lead to extensive morbidity and medical costs. © 2013 KUMS, All rights reserved.

  11. HUBUNGAN CITRA MERK BUS (MGI DENGAN KEPUASAN KONSUMEN PADA TRAYEK BANDUNG-SUKABUMI

    Directory of Open Access Journals (Sweden)

    Ulfa Chairunnisa

    2018-02-01

    Full Text Available This research aims to study correlation between brand image and customer satisfaction. Quantitative design using correlational method involved 350 MGI bus customer in Bandung-Sukabumi route. Instruments used are Brand Image Inventory (37 item and Customer Satisfaction Index (37 item. Cooeficient  correlation resulted is 0.684 which means that there is positive correlation between brand image and customer satisfction. High brand image correlated with high customer satisfaction while low brand image correlated with low customer satisfaction.

  12. Iodide-conducting polymer electrolytes based on poly-ethylene glycol and MgI2: Synthesis and structural characterization

    International Nuclear Information System (INIS)

    Vittadello, Michele; Waxman, David I.; Sideris, Paul J.; Gan Zhehong; Vezzù, Keti; Negro, Enrico; Safari, Ahmad; Greenbaum, Steve G.; Di Noto, Vito

    2011-01-01

    A major obstacle for a viable technological development of dye sensitized solar cells (DSSCs) is still the synthesis of a high performance iodide-conducting polymer electrolyte. Here we present a series of eight electrolytic complexes with formula PEG1000/(MgI 2 ) x (I 2 ) y (0.0038 ≤ x ≤ 0.5801, 0 ≤ y ≤ 0.0636). The synthesis involves the preparation of a disordered form of MgI 2 by a metallorganic route, which enables us to dissolve high amounts of salt in the chosen polymer host. The thermal analysis of the resulting polymer electrolytes was performed using modulated differential scanning calorimetry measurements. Vibrational studies were carried out using medium FT-IR, far FT-IR and FT-Raman. The variation of the CO and OH stretching modes in the medium infrared, as a function of the mole-to-mole ratio n Mg /n O , was investigated by Gaussian decomposition to provide insight into the polymer–polymer and salt–polymer interactions in these materials. The FT-Raman spectra confirmed and complemented the vibrational assignment. The conductivity study of these systems was performed by electrical spectroscopy in the frequency interval 10 mHz–10 MHz. The direct current conductivity (σ DC ) profiles versus the reciprocal temperature exhibited a Vögel-Tamman-Fülcher (VTF) behavior. The best σ DC at 50 °C was 5 × 10 −5 S cm −1 . The overall results indicate the presence of bivalent, monovalent and neutral species, Mg 2+ , [MgI] + and MgI 2 , respectively, which participate in the conduction process. These results are consistent with what was previously observed in PEG400-based systems doped with δ-MgCl 2 . The presence of at least one Mg site containing a distribution in parameters was observed using 25 Mg solid state magic angle spinning nuclear magnetic resonance (MAS NMR) spectroscopy. The site has been assigned to a Mg complex involving the coordination by oxygen atoms of the polymer backbone.

  13. Variable RNA expression from recently acquired, endogenous viral elements (EVE) of white spot syndrome virus (WSSV) in shrimp.

    Science.gov (United States)

    Utari, Heny Budi; Soowannayan, Chumporn; Flegel, Timothy W; Whityachumnarnkul, Boonsirm; Kruatrachue, Maleeya

    2017-11-01

    The viral accommodation hypothesis proposes that endogenous viral elements (EVE) from both RNA and DNA viruses are being continually integrated into the shrimp genome by natural host processes and that they can result in tolerance to viral infection by fortuitous production of antisense, immunospecific RNA (imRNA). Thus, we hypothesized that previously reported microarray results for the presence of white spot syndrome virus (WSSV) open reading frames (ORFs) formerly called 151, 366 and 427 in a domesticated giant tiger shrimp (Penaeus monodon) breeding stock might have represented expression from EVE, since the stock had shown uninterrupted freedom from white spot disease (WSD) for many generations. To test this hypothesis, 128 specimens from a current stock generation were confirmed for freedom from WSSV infection using two nested PCR detection methods. Subsequent nested-PCR testing revealed 33/128 specimens (26%) positive for at least one of the ORF at very high sequence identity (95-99%) to extant WSSV. Positive results for ORF 366 (now known to be a fragment of the WSSV capsid protein gene) dominated (28/33 = 84.8%), so 9 arbitrarily selected 366-positive specimens were tested by strand-specific, nested RT-PCR using DNase-treated RNA templates. This revealed variable RNA expression in individual shrimp including no RNA transcripts (n = 1), sense transcripts only (n = 1), antisense transcripts only (n = 2) or transcripts of both sense (n = 5). The latter 7 expression products indicated specimens producing putative imRNA. The variable types and numbers of the EVE and the variable RNA expression (including potential imRNA) support predictions of the viral accommodation hypothesis that EVE are randomly produced and expressed. Positive nested PCR test results for EVE of ORF 366 using DNA templates derived from shrimp sperm (germ cells), indicated that they were heritable. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. In situ electrochemical XRD study of (de)hydrogenation of MgyTi100-y thin films

    NARCIS (Netherlands)

    Vermeulen, P.; Wondergem, H.J.; Graat, P.C.J.; Borsa, D.M.; Schreuders, H.; Dam, B.; Griessen, R.; Notten, P.H.L.

    2008-01-01

    X-ray diffraction and electrochemical (de)hydrogenation were performed in situ to monitor the symmetry of the unit cells of MgyTi100-y thin film alloys (with 70 to 90 at.% Mg) along the pressure composition isotherms at room temperature. The diffraction patterns show that the crystal structures of

  15. A Partnership between English Language Learners and a Team of Rocket Scientists: EPO for the NASA SDO Extreme Ultraviolet Variability Experiment (EVE)

    Science.gov (United States)

    Buhr, S. M.; McCaffrey, M. S.; Eparvier, F.; Murillo, M.

    2008-05-01

    Recent immigrant high school students were successfully engaged in learning about Sun-Earth connections through a partnership with the NASA Solar Dynamics Observatory Extreme Ultraviolet Variability Experiment (EVE) project. The students were enrolled in a pilot course as part of the Math, Engineering and Science Achievement (MESA) program. The English Language Learner (ELL) students doubled their achievement on a pre- and post- assessment on the content of the course. Students learned scientific content and vocabulary in English with support in Spanish, attended field trips, hosted scientist speakers, built antenna and deployed space weather monitors as part of the Stanford SOLAR project, and gave final presentations in English, showcasing their new computer skills. Teachers who taught the students in other courses noted gains in the students' willingness to use English in class and noted gains in math skills. The course has been broken into modules for use in shorter after-school environments, or for use by EVE scientists who are outside of the Boulder area. Video footage of "The Making of a Satellite", and "All About EVE" is completed for use in the kits. Other EVE EPO includes upcoming professional development for teachers and content workshops for journalists.

  16. Exhibition from 6 to 17 March 2017: EVE and School covered in colours.

    CERN Multimedia

    Staff Association

    2017-01-01

    The children of the EVE and School exhibited their artwork in the Main Building from 6 to 17 March. They worked on the theme of “colours” expressing themselves through various drawing, painting, collage and arts-and-crafts techniques. The result was a beautiful explosion of bright and shimmering colours!

  17. A Partnership between English Language Learners and a Team of Rocket Scientists: EPO for the NASA SDO Extreme-Ultraviolet Variability Experiment (EVE)

    Science.gov (United States)

    Buhr, S. M.; Eparvier, F.; McCaffrey, M.; Murillo, M.

    2007-12-01

    Recent immigrant high school students were successfully engaged in learning about Sun-Earth connections through a partnership with the NASA SDO Extreme-Ultraviolet Variability Experiment (EVE) project. The students were enrolled in a pilot course as part of the Math, Engineering and Science Achievement MESA) program. For many of the students, this was the only science option available to them due to language limitations. The English Language Learner (ELL) students doubled their achievement on a pre- and post-assessment on the content of the course. Students learned scientific content and vocabulary in English with support in Spanish, attended field trips, hosted scientist speakers, built and deployed space weather monitors as part of the Stanford SOLAR project, and gave final presentations in English, showcasing their new computer skills. Teachers who taught the students in other courses noted gains in the students' willingness to use English in class and noted gains in math skills. The MESA-EVE course won recognition as a Colorado MESA Program of Excellence and is being offered again in 2007-08. The course has been broken into modules for use in shorter after-school environments, or for use by EVE scientists who are outside of the Boulder area. Other EVE EPO includes professional development for teachers and content workshops for journalists.

  18. Synthesis and characterization of BaxMgyAl2O4: Eu,Dy nanophosphors prepared using solution-combustion method

    CSIR Research Space (South Africa)

    Kebede, MA

    2011-07-01

    Full Text Available Europium-doped barium magnesium aluminate (BaxMgyAl2O4:Eu) phosphors were obtained at low temperature using the solution-combustion of corresponding metal nitrate-urea solution mixtures. The particle sizes, morphology, structural and luminescent...

  19. Project overview of OPTIMOS-EVE: the fibre-fed multi-object spectrograph for the E-ELT

    NARCIS (Netherlands)

    Navarro, R.; Chemla, F.; Bonifacio, P.; Flores, H.; Guinouard, I.; Huet, J.-M.; Puech, M.; Royer, F.; Pragt, J.H.; Wulterkens, G.; Sawyer, E.C.; Caldwell, M.E.; Tosh, I.A.J.; Whalley, M.S.; Woodhouse, G.F.W.; Spanò, P.; Di Marcantonio, P.; Andersen, M.I.; Dalton, G.B.; Kaper, L.; Hammer, F.

    2010-01-01

    OPTIMOS-EVE (OPTical Infrared Multi Object Spectrograph - Extreme Visual Explorer) is the fibre fed multi object spectrograph proposed for the European Extremely Large Telescope (E-ELT), planned to be operational in 2018 at Cerro Armazones (Chile). It is designed to provide a spectral resolution of

  20. The ADAM and EVE project: Heat transfer at ambient temperature

    International Nuclear Information System (INIS)

    Boltendahl, U.; Harth, R.

    1980-01-01

    In the nuclear research plant at Juelich a new heating system is at present being developed as part of the Nuclear Long-distance Heating Project. Helium is heated up in a high-temperature reactor. The heat chemically converts a gas mixture in a reformer plant (EVE). The gases 'charged' with energy can be transported through tubes over any distance required at ambient temperatures. In a methanisation plant (ADAM) the gases react with one another, releasing the energy in the form of heat which can be used for heating air or water. (orig.) [de

  1. Mille poolest on algav õppeaasta teile eriline? / Valmar Pantšenko, Martin Adamson, Maire Tamm, Eve Reisalu

    Index Scriptorium Estoniae

    2012-01-01

    Küsimusele vastavad: Tartu Täiskasvanute Gümnaasiumi abiturient Valmar Pantšenko, Eesti meister motokrossis klassis Quad 100 Martin Adamson, Tamsalu Gümnaasiumi õppealajuhataja Maire Tamm ja Ristiku põhikooli õpetaja-metoodik Eve Reisalu

  2. Immuno-enhancement in tumor-bearing mice induced by whole body X-irradiation with 75 mGy

    International Nuclear Information System (INIS)

    Zhang Ying; Li Xiuyi; Gong Shouliang; Liu Shuzheng

    2000-01-01

    Objective: In present study the authors observed the effect of whole body irradiation (WBI) with 75 mGy X-rays on the immune function of tumor-bearing mice. Methods: Lewis lung carcinoma cells were implanted into the right thigh muscle of C57BL/6J mice. Ten days after tumor implantation, the tumor-bearing mice were administrated with 75 mGy X-rays WBI, then the mice were sacrificed 18 h after irradiation to detect the immune parameters including the spontaneous proliferation of thymocytes, the proliferative response of splenocytes to ConA and LPS, the cytotoxic activities of specific cytotoxic lymphocytes (CTL) and natural killer cells (NK), as well as lymphokine activated killer cells (LAK) in spleen. The methods the authors used were 3 H-TdR incorporation or release assay. Results: the immune parameters of exposed tumor-bearing mice were much higher than those of sham-irradiated tumor-bearing mice (P<0.01). Conclusion: These results suggested that low dose radiation (LDR) could enhance the immune function of tumor-bearing mice, which might be of practical significance in the prevention and therapy of cancer

  3. 78 FR 75248 - Safety Zone; Sacramento New Years Eve Fireworks Display, Sacramento River, Sacramento, CA

    Science.gov (United States)

    2013-12-11

    ... Zone; Sacramento New Years Eve Fireworks Display, Sacramento River, Sacramento, CA AGENCY: Coast Guard... safety zone in the navigable waters of the Sacramento River in Sacramento, CA on December 31, 2013 during... Sacramento River around the Tower Bridge in Sacramento, CA in approximate position 38[deg]34'49.98'' N, 121...

  4. 78 FR 75898 - Safety Zone; Sacramento New Years Eve Fireworks Display, Sacramento River, Sacramento, CA

    Science.gov (United States)

    2013-12-13

    ... Zone; Sacramento New Years Eve Fireworks Display, Sacramento River, Sacramento, CA AGENCY: Coast Guard... safety zone in the navigable waters of the Sacramento River in Sacramento, CA on December 31, 2013 during... Sacramento River around the Tower Bridge in Sacramento, CA in approximate position 38[deg]34'49.98'' N, 121...

  5. Optimal conditions of LDR to protect the kidney from diabetes: exposure to 12.5 mGy X-rays for 8 weeks efficiently protects the kidney from diabetes.

    Science.gov (United States)

    Cheng, Jie; Li, Fengsheng; Cui, Jiuwei; Guo, Weiying; Li, Cai; Li, Wei; Wang, Guixia; Xing, Xiao; Gao, Ying; Ge, Yuanyuan; Wang, Guanjun; Cai, Lu

    2014-05-08

    We reported the attenuation of diabetes-induced renal dysfunction by exposure to multiple low-dose radiation (LDR) at 25 mGy every other day by suppressing renal oxidative damage. We here explored the optimal conditions of LDR to protect the kidney from diabetes. Male C57BL/6J mice with type 1 diabetes were induced with multiple injections of low-dose streptozotocin. Diabetic mice received whole body X-irradiation at a dose of 12.5, 25 or 50 mGy every other day for either 4 or 8 weeks. Age-matched normal mice were similarly irradiated at the dose of 25 mGy for 4 or 8 weeks. The renal function and histopathological changes were examined at the 4th and 8th weeks of the study. Diabetes induced renal dysfunction is shown by the decreased creatinine and increased microalbumin in the urine. Renal oxidative damage, detected by protein nitration and lipid oxidation, and remodeling, reflected by increased expression of connective tissue growth factor, collagen IV and fibronectin, were significantly increased in diabetic mice. All these renal pathological and function changes in diabetic mice were significantly attenuated by exposure to LDR at all regimens, among which, however, exposure to LDR at 12.5 mGy for 8 weeks provided the best protective effect on the kidney of diabetic mice. Our results suggest that whole-body LDR at 12.5 mGy every other day for 8 weeks is the optimal condition of LDR to protect the kidney from diabetes. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. On the eve of Copenhagen: Obama and the environment

    International Nuclear Information System (INIS)

    Pereon, Y.M.

    2009-01-01

    The author proposes a rather detailed overview of the United States posture with respect to climate change challenges on the eve of the Copenhagen conference. First, he shows how the public opinion in the United States is ambivalent and changing. Then, he outlines that the arrival of President Obama resulted in an important change for the United States environmental policy: a new team was set up and the environment protection became a priority. The author then reports the Congressional process for this policy, first through the House of Representatives, and then the Senate. He highlights the differences between agendas of firms and of environment protection organisations, and between that of the Copenhagen conference and that of the US government

  7. Design of a MGy radiation tolerant resolver-to-digital convertor IC for remotely operated maintenance in harsh environments

    Energy Technology Data Exchange (ETDEWEB)

    Leroux, Paul, E-mail: paul.leroux@kuleuven.be [KU Leuven, Dept. of Electrical Engineering (ESAT), AdvISe, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Koeckhoven, Wesley; Verbeeck, Jens [KU Leuven, Dept. of Electrical Engineering (ESAT), AdvISe, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Uffelen, Marco; Esqué, Salvador; Ranz, Roberto; Damiani, Carlo [Fusion for Energy, Torres Diagonal Litoral B3, Josep Pla 2, 08019 Barcelona (Spain); Hamilton, David [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France)

    2014-10-15

    During future ITER maintenance operations, sensors and their embarked electronics will be exposed to a hostile and radioactive environment. This paper presents the design of a MGy radiation tolerant 16 bit resolver-to-digital converter (RDC) in 130 nm CMOS technology. The RDC features a Type II digital tracking loop, able to track resolvers with speeds up to 300 rps, and excitation frequencies up to 4 kHz. The RDC uses two integrated ΔΣ-analog-to-digital converters (ADCs) to digitize the resolver outputs. The 16 bit, 10 kHz ADCs utilize a correlated double sampling technique to remove radiation induced offset and 1/f-noise. The front-end features a static angular resolution of 16 bits (4.2 arcsec{sub rms}) and a resolution of 10 bits (6 arcmin{sub rms}) at a rotor speed of 100 rps. The circuit has a simulated radiation tolerance exceeding 1 MGy. It has the ability to operate under temperatures up to 125 °C, and to allow multiplexing with signals from other conventional sensors for compact, robust read-out architectures.

  8. 76 FR 78820 - Safety Zone; City of Beaufort's Tricentennial New Year's Eve Fireworks Display, Beaufort River...

    Science.gov (United States)

    2011-12-20

    ...-AA00 Safety Zone; City of Beaufort's Tricentennial New Year's Eve Fireworks Display, Beaufort River... establishing a temporary safety zone on the Beaufort River, in Beaufort, South Carolina, during the City of... Carolina. The fireworks will be launched from a barge, which will be located on the Beaufort River. The...

  9. Open Day at EVE and School of CERN Staff Association: an opportunity for many parents to discover the structure.

    CERN Multimedia

    Staff Association

    2017-01-01

    On Saturday, 4 March 2017, the Children’s Day-Care Centre EVE and School of CERN Staff Association opened its doors to allow interested parents to visit the structure. Staff Association - Carole Dargagnon presents the EVE and school during the open day. This event was a great success and brought together many families. The Open Day was held in two sessions (first session at 10 am and second at 11 am), each consisting in two parts: a general presentation of the structure by the Headmistress Carole Dargagnon, a tour of the installations with Marie-Luz Cavagna and Stéphanie Palluel, the administrative assistants. The management team was delighted to offer parents the opportunity to participate in this pleasant event, where everyone could express themselves, ask questions and find answers in a friendly atmosphere.

  10. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  11. Deaf-Accessibility for Spoonies: Lessons from Touring "Eve and Mary Are Having Coffee" While Chronically Ill

    Science.gov (United States)

    Barokka (Okka), Khairani

    2017-01-01

    This article presents lessons from touring a show on pain with limited resources and in chronic pain. In 2014, I toured solo deaf-accessible poetry/art show "Eve and Mary Are Having Coffee" in various forms in the UK, Austria, and India. As an Indonesian woman with then-extreme chronic pain and fatigue, herein are lessons learned from…

  12. [Eve Hele Sits. Mooni talurahva tähtpäevik ; Mooni metsauudistaja ; Mooni Eestimaa raamat ] / Helja Kirber ; suomennos Katariina Suurpalo

    Index Scriptorium Estoniae

    Kirber, Helja

    2014-01-01

    Tutvustus: Sits, Eve Hele. Mooni talurahva tähtpäevik. [Tallinn] : Argo, c2011; Mooni metsauudistaja : tähelepanekuid ja lugusid metsaelust. [Tallinn] : Argo, c2012; Mooni Eestimaa raamat. [Tallinn] : Argo, c2013

  13. Problems afoot for the CERN kindergarten (EVEE)?

    CERN Multimedia

    Staff Association

    2016-01-01

    You might have noticed that recently the Kindergarten changed names, it’s is now known under the name of EVEE which stands for ‘Espace de Vie Enfantine et École’ and currently welcomes 150 children between 4 months and 6 years of age. This establishment which is under the aegis of the Staff Association is governed by a committee composed of a mixture of the following: employers (from the Staff Association), employees, parents and the Headmistress who is an ex officio member (see Echo 238: http://staff-association.web.cern.ch/content/quoi-de-neuf-au-jardin-d%E2%80%99enfants). Great strides have been made in the past decade Over the previous decade in conjuction with the CERN Administration several new services have been proposed, including: the establishment of a canteen with a capacity of up to 60 children/day; the setting-up of a creche for infants ranging between 4 months and 3 years (approx 35 infants); the creation of a day-camp with the capacity to welcome up ...

  14. Kick off of the 2017-2018 school year at the EVE and School of the CERN Staff Association

    CERN Multimedia

    Staff Association

    2017-01-01

    The Children’s Day-Care Centre (“Espace de Vie Enfantine” - EVE) and School of the CERN Staff Association opened its doors once again to welcome the children, along with the teaching and administrative staff of the structure. The start of the school year was carried out gradually and in small groups to allow quality interaction between children, professionals and parents. At the EVE (Nursery and Kindergarten) and School, the children have the opportunity to thrive in a privileged environment, rich in cultural diversity, since the families (parents and children) come from many different nationalities. The teaching staff do their utmost to ensure that the children can become more autonomous and develop their social skills, all the while taking care of their well-being. This year, several new features are being introduced, for instance, first steps towards English language awareness. Indeed, the children will get to discover the English language in creative classes together with tr...

  15. Inspiratsiooni lätetel Amsterdamis : kuhu püüelda ja millest hoiduda... / Eve Koha

    Index Scriptorium Estoniae

    Koha, Eve

    2002-01-01

    Ülemaailmse klaasikunsti ühingu Glass Art Society 32. aastakonverentsist Amsterdamis 30. V-2. VI. Eestist osalesid Viivi-Ann Keerdo, Eve Koha, Kai Koppel, Eeva Käsper-Lennuk, Ivo Lill ja Tiina Sarapu. Näitusel "Young and Hot, European Emerging Artists" esindasid Eestit E. Käsper-Lennuk ja T. Sarapu. Elutööpreemiad ameeriklasele Fritz Dreisbachile (sünd. 1941) ja taanlasele Finn Lynggaardile (sünd. 1939)

  16. Polymer-based blood vessel models with micro-temperature sensors in EVE

    Science.gov (United States)

    Mizoshiri, Mizue; Ito, Yasuaki; Hayakawa, Takeshi; Maruyama, Hisataka; Sakurai, Junpei; Ikeda, Seiichi; Arai, Fumihito; Hata, Seiichi

    2017-04-01

    Cu-based micro-temperature sensors were directly fabricated on poly(dimethylsiloxane) (PDMS) blood vessel models in EVE using a combined process of spray coating and femtosecond laser reduction of CuO nanoparticles. CuO nanoparticle solution coated on a PDMS blood vessel model are thermally reduced and sintered by focused femtosecond laser pulses in atmosphere to write the sensors. After removing the non-irradiated CuO nanoparticles, Cu-based microtemperature sensors are formed. The sensors are thermistor-type ones whose temperature dependences of the resistance are used for measuring temperature inside the blood vessel model. This fabrication technique is useful for direct-writing of Cu-based microsensors and actuators on arbitrary nonplanar substrates.

  17. Paradise Lost: Difference Between Adam and Eve's Lament on Leaving Paradise - a Contrastive Analysis

    OpenAIRE

    Servín, Sara Torres

    2013-01-01

    The difference between Adam and Eve’s lament on leaving Paradise in Milton’s Paradise Lost is striking in its contrastive content and depth. This paper analyzes the difference that exists between the feelings and spiritual attitudes that Adam and Eve express on the occasion when they are informed by the angel Michael that they have to abandon the Garden of Eden. It is a comparison of their lament in order to understand the contrast of the two attitudes that Milton wove in the tapestry that Pa...

  18. A > 4 MGy radiation tolerant 8 THzOhm transimpedance amplifier with 50 dB dynamic range

    International Nuclear Information System (INIS)

    Verbeeck, J; Steyaert, M; Leroux, P

    2013-01-01

    A 130 nm Transimpedance Amplifier has been developed with a 255 MHz bandwidth, 90 dBΩ transimpedance gain and a dynamic input range of 1:325 or 50 dB for a photo-diode capacitance of 0.75 pF. The equivalent integrated input noise is 160 nA - 25°C. The gain of the voltage amplifier, used in the transimpedance amplifier (TIA), degrades less than 3% over a temperature range from -40 °C up to 125 °C. The TIA and attenuator exhibit a radiation tolerance larger than 4 MGy, as evidenced by radiation assessment.

  19. Resolving Differences in Absolute Irradiance Measurements Between the SOHO/CELIAS/SEM and the SDO/EVE.

    Science.gov (United States)

    Wieman, S R; Didkovsky, L V; Judge, D L

    The Solar EUV Monitor (SEM) onboard SOHO has measured absolute extreme ultraviolet (EUV) and soft X-ray solar irradiance nearly continuously since January 1996. The EUV Variability Experiment (EVE) on SDO, in operation since April of 2010, measures solar irradiance in a wide spectral range that encompasses the band passes (26 - 34 nm and 0.1 - 50 nm) measured by SOHO/SEM. However, throughout the mission overlap, irradiance values from these two instruments have differed by more than the combined stated uncertainties of the measurements. In an effort to identify the sources of these differences and eliminate them, we investigate in this work the effect of reprocessing the SEM data using a more accurate SEM response function (obtained from synchrotron measurements with a SEM sounding-rocket clone instrument taken after SOHO was already in orbit) and time-dependent, measured solar spectral distributions - i.e ., solar reference spectra that were unavailable prior to the launch of the SDO. We find that recalculating the SEM data with these improved parameters reduces mean differences with the EVE measurements from about 20 % to less than 5 % in the 26 - 34 nm band, and from about 35 % to about 15 % for irradiances in the 0.1 - 7 nm band extracted from the SEM 0.1 - 50 nm channel.

  20. Registrations for EVE and School and Summer Camp

    CERN Multimedia

    Staff Association

    2017-01-01

    In the wake of the Open Day, held on Saturday, 4 March 2017 (see Echo No. 264), EVE and School launched into an enrolment campaign on 6, 7 and 8 March. Once again, this year, we registered a great number of applications, and most of the groups are now full. The Nursery is already full, including the groups for babies (4 months to 1 year old), walkers (1 to 2 years old), and 2- to 3-year-olds. Regarding the Kindergarten, which welcomes 2- to 3 year-old children enrolled for mornings, as well as 3- to 4-year-olds enrolled either for mornings or for full days, there are still places available in the morning groups. Finally, the School for children aged 4 to 6 (Primary 1 and 2) enrolled for mornings or for full days, will be composed of three classes of around twenty children in 2017–2018 (one class of P1 and two classes of P2). All of these classes are currently full. If you are interested in a place in the morning groups of the Kindergarten (2- to 4-year-olds), please contact us to enroll your ...

  1. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    International Nuclear Information System (INIS)

    Cao, Y.; Leroux, P.; De Cock, W.; Steyaert, M.

    2011-01-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma (ΔΣ) TDC structure is proposed. The converter, implemented in 0.13 μm, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm 2 . Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g m biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  2. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Y. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Leroux, P. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); ICT-RELIC Div., Katholieke Hogeschool Kempen, B-2440 Geel (Belgium); De Cock, W. [SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Steyaert, M. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium)

    2011-07-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma ({Delta}{Sigma}) TDC structure is proposed. The converter, implemented in 0.13 {mu}m, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm{sup 2}. Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g{sub m} biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  3. Suur rahvusvaheline välisbalti arhiivide konverents südasuvises Tartus / Mai Raud-Pähn ; fotod Madis Laas

    Index Scriptorium Estoniae

    Raud-Pähn, Mai, 1920-

    2006-01-01

    Ettekannetega esinesid: Tiiu Kravtsev, Riina Reinvelt, Juta Kivimäe, Piret Noorhani, Merike Kiipus, Anu Korb, Anne Valmas, Mihkel Volt, Mare Rand, Inga Kuljus, Enn Mainla, Roland Weiler, Teas Tanner, Tiina Kirss, Jüri Kivimäe, Enda-Mai Michelson-Holland, Andrae, Carl Göran, Katrin Meerits ja Maie Barrow

  4. Total body 100-mGy X-irradiation does not induce Alzheimer's disease-like pathogenesis or memory impairment in mice

    International Nuclear Information System (INIS)

    Wang, Bing; Tanaka, Kaoru; Ji, Bin

    2014-01-01

    The cause and progression of Alzheimer's disease (AD) are poorly understood. Possible cognitive and behavioral consequences induced by low-dose radiation are important because humans are exposed to ionizing radiation from various sources. Early transcriptional response in murine brain to low-dose X-rays (100 mGy) has been reported, suggesting alterations of molecular networks and pathways associated with cognitive functions, advanced aging and AD. To investigate acute and late transcriptional, pathological and cognitive consequences of low-dose radiation, we applied an acute dose of 100-mGy total body irradiation (TBI) with X-rays to C57BL/6J Jms mice. We collected hippocampi and analyzed expression of 84 AD-related genes. Mouse learning ability and memory were assessed with the Morris water maze test. We performed in vivo PET scans with 11 C-PIB, a radiolabeled ligand for amyloid imaging, to detect fibrillary amyloid beta peptide (Aβ) accumulation, and examined characteristic AD pathologies with immunohistochemical staining of amyloid precursor protein (APP), Aβ, tau and phosphorylated tau (p-tau). mRNA studies showed significant downregulation of only two of 84 AD-related genes, Apbb1 and Lrp1, at 4 h after irradiation, and of only one gene, Il1α, at 1 year after irradiation. Spatial learning ability and memory were not significantly affected at 1 or 2 years after irradiation. No induction of amyloid fibrillogenesis or changes in APP, Aβ, tau, or p-tau expression was detected at 4 months or 2 years after irradiation. TBI induced early or late transcriptional alteration in only a few AD-related genes but did not significantly affect spatial learning, memory or AD-like pathological change in mice. (author)

  5. Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tonkopi, E; Ross, AA [Department of Diagnostic Imaging, Queen Elizabeth II Health Sciences Centre, CDHA (Canada); Department of Radiology, Dalhousie University (Canada)

    2014-08-15

    Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

  6. Thermodynamic Spectrum of Solar Flares Based on SDO/EVE Observations: Techniques and First Results

    Science.gov (United States)

    Wang, Yuming; Zhou, Zhenjun; Zhang, Jie; Liu, Kai; Liu, Rui; Shen, Chenglong; Chamberlin, Phillip C.

    2016-01-01

    The Solar Dynamics Observatory (SDO)/EUV Variability Experiment (EVE) provides rich information on the thermodynamic processes of solar activities, particularly on solar flares. Here, we develop a method to construct thermodynamic spectrum (TDS) charts based on the EVE spectral lines. This tool could potentially be useful for extreme ultraviolet (EUV) astronomy to learn about the eruptive activities on distant astronomical objects. Through several cases, we illustrate what we can learn from the TDS charts. Furthermore, we apply the TDS method to 74 flares equal to or greater than the M5.0 class, and reach the following statistical results. First, EUV peaks are always behind the soft X-ray (SXR) peaks and stronger flares tend to have faster cooling rates. There is a power-law correlation between the peak delay times and the cooling rates, suggesting a coherent cooling process of flares from SXR to EUV emissions. Second, there are two distinct temperature drift patterns, called Type I and Type II. For Type I flares, the enhanced emission drifts from high to low temperature like a quadrilateral, whereas for Type II flares the drift pattern looks like a triangle. Statistical analysis suggests that Type II flares are more impulsive than Type I flares. Third, for late-phase flares, the peak intensity ratio of the late phase to the main phase is roughly correlated with the flare class, and the flares with a strong late phase are all confined. We believe that the re-deposition of the energy carried by a flux rope, which unsuccessfully erupts out, into thermal emissions is responsible for the strong late phase found in a confined flare. Furthermore, we show the signatures of the flare thermodynamic process in the chromosphere and transition region in the TDS charts. These results provide new clues to advance our understanding of the thermodynamic processes of solar flares and associated solar eruptions, e.g., coronal mass ejections.

  7. THERMODYNAMIC SPECTRUM OF SOLAR FLARES BASED ON SDO/EVE OBSERVATIONS: TECHNIQUES AND FIRST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuming; Zhou, Zhenjun; Liu, Kai; Liu, Rui; Shen, Chenglong [CAS Key Laboratory of Geospace Environment, Department of Geophysics and Planetary Sciences, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhang, Jie [School of Physics, Astronomy and Computational Sciences, George Mason University, 4400 University Drive, MSN 6A2, Fairfax, VA 22030 (United States); Chamberlin, Phillip C., E-mail: ymwang@ustc.edu.cn [Solar Physics Laboratory, Heliophysics Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2016-03-15

    The Solar Dynamics Observatory (SDO)/EUV Variability Experiment (EVE) provides rich information on the thermodynamic processes of solar activities, particularly on solar flares. Here, we develop a method to construct thermodynamic spectrum (TDS) charts based on the EVE spectral lines. This tool could potentially be useful for extreme ultraviolet (EUV) astronomy to learn about the eruptive activities on distant astronomical objects. Through several cases, we illustrate what we can learn from the TDS charts. Furthermore, we apply the TDS method to 74 flares equal to or greater than the M5.0 class, and reach the following statistical results. First, EUV peaks are always behind the soft X-ray (SXR) peaks and stronger flares tend to have faster cooling rates. There is a power-law correlation between the peak delay times and the cooling rates, suggesting a coherent cooling process of flares from SXR to EUV emissions. Second, there are two distinct temperature drift patterns, called Type I and Type II. For Type I flares, the enhanced emission drifts from high to low temperature like a quadrilateral, whereas for Type II flares the drift pattern looks like a triangle. Statistical analysis suggests that Type II flares are more impulsive than Type I flares. Third, for late-phase flares, the peak intensity ratio of the late phase to the main phase is roughly correlated with the flare class, and the flares with a strong late phase are all confined. We believe that the re-deposition of the energy carried by a flux rope, which unsuccessfully erupts out, into thermal emissions is responsible for the strong late phase found in a confined flare. Furthermore, we show the signatures of the flare thermodynamic process in the chromosphere and transition region in the TDS charts. These results provide new clues to advance our understanding of the thermodynamic processes of solar flares and associated solar eruptions, e.g., coronal mass ejections.

  8. The Stuff of Christmas Homemaking: Transforming the House and Church on Christmas Eve in the Bay of Kotor, Montenegro

    Directory of Open Access Journals (Sweden)

    Vesna Vučinić-Nešković

    2016-03-01

    Full Text Available The domestic burning of Yule logs on Christmas Eve is an archaic tradition characteristic of the Christian population in the central Balkans. In the fifty years following World War Two, the socialist state suppressed these and other popular religious practices. However, ethnographic research in Serbia and Montenegro in the late 1980s showed that many village households, nevertheless, preserved their traditional Christmas rituals at home, in contrast to the larger towns, in which they were practically eradicated. Even in the micro-regions, such as the Bay of Kotor, there were observable differences between more secluded rural communities, in which the open hearth is still the ritual center of the house (on which the Yule logs are burned as many as seven times during the Christmas season, and the towns in which only a few households continued with the rite (burning small logs in the wood-stove. In the early 1990s, however, a revival of domestic religious celebrations as well as their extension into the public realm has occurred. This study shows how on Christmas Eve, houses and churchyards (as well as townsquares are being transformed into sacred places. By analyzing the temporal and spatial aspects of this ritual event, the roles that the key actors play, the actions they undertake and artifacts they use, I attempt to demonstrate how the space of everyday life is transformed into a sacred home. In the end, the meanings and functions of homemaking are discussed in a way that confronts the classic distinction between private and public ritual environs.

  9. The EVE plus RHESSI DEM for Solar Flares, and Implications for Residual Non-Thermal X-Ray Emission

    Science.gov (United States)

    McTiernan, James; Caspi, Amir; Warren, Harry

    2016-05-01

    Solar flare spectra are typically dominated by thermal emission in the soft X-ray energy range. The low energy extent of non-thermal emission can only be loosely quantified using currently available X-ray data. To address this issue, we combine observations from the EUV Variability Experiment (EVE) on-board the Solar Dynamics Observatory (SDO) with X-ray data from the Reuven Ramaty High Energy Spectroscopic Imager (RHESSI) to calculate the Differential Emission Measure (DEM) for solar flares. This improvement over the isothermal approximation helps to resolve the ambiguity in the range where the thermal and non-thermal components may have similar photon fluxes. This "crossover" range can extend up to 30 keV.Previous work (Caspi et.al. 2014ApJ...788L..31C) concentrated on obtaining DEM models that fit both instruments' observations well. For this current project we are interested in breaks and cutoffs in the "residual" non-thermal spectrum; i.e., the RHESSI spectrum that is left over after the DEM has accounted for the bulk of the soft X-ray emission. As in our earlier work, thermal emission is modeled using a DEM that is parametrized as multiple gaussians in temperature. Non-thermal emission is modeled as a photon spectrum obtained using a thin-target emission model ('thin2' from the SolarSoft Xray IDL package). Spectra for both instruments are fit simultaneously in a self-consistent manner.For this study, we have examined the DEM and non-thermal resuidual emission for a sample of relatively large (GOES M class and above) solar flares observed from 2011 to 2014. The results for the DEM and non-thermal parameters found using the combined EVE-RHESSI data are compared with those found using only RHESSI data.

  10. [Sanitary service of West Special Military District on the eve and in the first days of the Great Patriotic War of 1941-1945].

    Science.gov (United States)

    Shelepov, A M; Ishutin, O S; Leonik, S I

    2011-06-01

    This article evaluates military and political situation in the world and operational-strategic environment on the West Theater of operations on the eve of the Great Patriotic War (1941-1945). We analyze structure and overall condition of sanitary service of West Special Military District of the Workers and Peasants Red Army and causes of failure of mobilization, organization and deployment of military units and establishments from the beginning of aggression of Fascist Germany to the Soviet Union.

  11. The Eroticism of Artificial Flesh in Villiers de L'Isle Adam's L'Eve Future

    Directory of Open Access Journals (Sweden)

    Patricia Pulham

    2008-10-01

    Full Text Available Villiers de L'Isle Adam's 'L'Eve Future' published in 1886 features a fictional version of the inventor Thomas Edison who constructs a complex, custom-made android for Englishman Lord Ewald as a substitute for his unsatisfactory lover. Hadaly, the android, has a number of literary and cultural precursors and successors. Her most commonly accepted ancestor is Olympia in E. T. A. Hoffmann's 'The Sandman' (1816 and among her fascinating descendants are Oskar Kokoschka's 'Silent Woman'; Model Borghild, a sex doll designed by German technicians during World War II;‘Caracas' in Tommaso Landolfi's short story ‘Gogol's Wife' (1954; a variety of gynoids and golems from the realms of science fiction, including Ira Levin's 'Stepford Wives' (1972; and, most recently, that silicon masterpiece - the Real Doll. All, arguably, have their genesis in the classical myth of Pygmalion. This essay considers the tension between animation and stasis in relation to this myth, and explores the necrophiliac aesthetic implicit in Villiers's novel.

  12. Start of enrolment for the Champs-Fréchets crèche (EVE)

    CERN Multimedia

    HR Department

    2008-01-01

    As announced in Bulletin 43/2007, CERN signed an agreement with the commune of Meyrin on 17 October 2007 under which 20 places will be reserved for the children of CERN personnel in the Champs-Fréchets day care centre (EVE), which will open on Monday, 25 August, and CERN will contribute to the funding. This agreement allows members of the CERN personnel (employees and associates) access to the crèche, for children aged between 4 months and 4 years, irrespective of where they are living. Applications for the school year starting autumn 2008 will be accepted from Monday 17 March until Monday 30 June 2008. Members of the personnel must complete the enrolment formalities with the Meyrin infant education service themselves: Mairie de Meyrin Service de la Petite Enfance 2 rue des Boudines Case postale 367 - 1217 Meyrin 1 - Tel. + 41 (0)22 782 21 21 mailto:meyrin@meyrin.ch http://www.meyrin.ch/petiteenfance Application forms (in PDF) can be downloaded from the website of the com...

  13. Study on the early surface films formed on Mg-Y molten alloy in different atmospheres

    Directory of Open Access Journals (Sweden)

    A.R. Mirak

    2015-09-01

    Full Text Available In the present study, the non-isothermal early stages of surface oxidation of liquid Mg-1%Y alloy during casting were studied under UPH argon, dry air, and air mixed with protective fluorine-bearing gases. The chemistry and morphology of the surface films were characterized by SEM and EDX analyses. The results indicate a layer of smooth and tightly coherent oxidation film composed of MgO and Y2O3 formed on the molten Mg-Y alloy surface with 40–60 nm thickness under dry air. A dendritic/cellular microstructure is clearly visible with Y-rich second phases gathered in surface of the melt and precipitated along the grain/cell boundaries under all gas conditions. Under fluorine-bearing gas mixtures, the surface film was a mixed oxide and fluoride and more even; a flat and folded morphology can be seen under SF6 with oxide as dominated phase and under 1, 1, 1, 2-tetra-fluoroethane, a smooth and compact surface film uniformly covering the inner surface of the bubble with equal oxide and fluoride thickness, which results in a film without any major defects. MgF2 phase appears to be the key characteristic of a good protective film.

  14. A surprise southern hemisphere meteor shower on New-Year's Eve 2015: the Volantids (IAU#758, VOL)

    Science.gov (United States)

    Jenniskens, P.; Baggaley, J.; Crumpton, I.; Aldous, P.; Gural, P. S.; Samuels, D.; Albers, J.; Soja, R.

    2016-04-01

    A new 32-camera CAMS network in New Zealand, spread over two stations on South Island, has detected a high southern declination shower that was active on New Year's Eve, 2015 December 31. During the observing interval from 09h12m - 15h45m UT, 21 out of 59 detected meteors radiated from the constellation of Volans, the flying fish, with a geocentric radiant at RA = 122.9 deg +- 4.7 deg, Dec = -71.9 deg +- 1.9 deg, and speed V_g = 28.4 +- 1.5 km/s. The new year arrived in New Zealand at 11h00m UT. Two more were detected the next night. No activity from this shower was observed the year prior. The meteoroids move in a 48 deg-inclined Jupiter-family comet orbit. The parent body has not yet been identified.

  15. Measurements of the branching fractions for the semileptonic decays D-s(+) -> phi e(+)v(e), phi mu(+)v(mu), eta mu(+)v(mu) and eta 'mu(+)v(mu)

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M.N.; Ahmed, S.; Albrecht, M.; Amoroso, A.; An, F. F.; An, Q.; Haddadi, Z.; Kalantar-Nayestanaki, N.; Kavatsyuk, M.; Messchendorp, J. G.; Tiemens, M.

    2018-01-01

    By analyzing 482 pb(-1) of e(+) e(-) collision data collected at the center-of-mass energy root s = 4.009 GeV with the BESIII detector, we measure the branching fractions for the semi-leptonic decays D-s(+) -> phi e(+)v(e), phi mu(+)v(mu), eta mu(+)v(mu) and eta'mu(+)v(mu) to be B(D-s(+) -> phi

  16. Children’s Day-Care Centre (EVE) and School kicked off the school year 2016-2017

    CERN Multimedia

    Staff Association

    2016-01-01

    It has been 54 years already, ever since the Nursery school was founded in March 1961, that the Staff Association together with the teachers, the managerial and the administrative staff, welcomes your children at the start of the school year. On Tuesday, 30 August 2016, the Children’s Day-Care Centre (EVE) and School opened its doors again for children between four months and six years old. The start of the school year was carried out gradually and in small groups to allow quality interaction between children, professionals and parents. This year, our structure will accommodate about 130 children divided between the nursery, the kindergarten and the school. Throughout the school year, the children will work on the theme of colours, which will be the common thread linking all our activities. Our team is comprised of 38 people: the headmistress, the deputy headmistress, 2 secretaries, 13 educators, 4 teachers, 11 teaching assistants, 2 nursery assistants and 4 canteen workers. The team is delighted...

  17. Lillekleidid lilleballil / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2001-01-01

    Lillekleitide võistlus ööklubis "Flamingo". Esikoha võidutöö "Primavera del a more" autor Ljubov Gutman, teisele kohale jäi Jana Nautsi töö. Kolmas koht läks jagamisele Janis Bucevichi ning kahe floristi, Svetlana Osjenko ja Karina Saberi vahel. Publiku auhind läks Heiti Põdrale

  18. Moralized Hygiene and Nationalized Body: Anti-Cigarette Campaigns in China on the Eve of the 1911 Revolution

    Directory of Open Access Journals (Sweden)

    Wennan Liu

    2013-03-01

    Full Text Available Western knowledge about the injurious effects of cigarette smoking on smokers’ health appeared in the late nineteenth century and was shaped by both the Christian temperance movement and scientific developments in chemistry and physiology. Along with the increasing import of cigarettes into China, this new knowledge entered China through translations published at the turn of the twentieth century. It was reinterpreted and modified to dissuade the Chinese people from smoking cigarettes in two anti-cigarette campaigns: one launched by a former American missionary, Edward Thwing, in Tianjin, and a second by progressive social elites in Shanghai on the eve of the 1911 Revolution. By examining the rhetoric and practice of the campaigns, I argue that the discourse of hygiene they deployed moralized the individual habit of cigarette smoking as undermining national strength and endangering the future of the Chinese nation, thus helping to construct the idea of a nationalized body at this highly politically charged moment.

  19. Firework-related injuries in Tehran's Persian Wednesday Eve Festival (Chaharshanbe Soori).

    Science.gov (United States)

    Tavakoli, Hassan; Khashayar, Patricia; Amoli, Hadi Ahmadi; Esfandiari, Khalil; Ashegh, Hossein; Rezaii, Jalal; Salimi, Javad

    2011-03-01

    Fireworks are the leading cause of injuries such as burns and amputations during the Persian Wednesday Eve Festival (Chaharshanbeh Soori). This study was designed to explore the age of the high-risk population, the type of fireworks most frequently causing injury, the pattern of injury, and the frequency of permanent disabilities. This cohort study was performed by Tehran Emergency Medical Services at different medical centers all around Tehran, Iran, in individuals referred due to firework-related injuries during 1 month surrounding the festival in the year 2007. The following information was extracted from the patients' medical records: demographic data, the type of fireworks causing injury, the pattern and severity of the injury, the pre-hospital and hospital care provided for the patient, and the patient's condition at the time of discharge. In addition, information on the severity of the remaining disability was recorded 8 months after the injury. There were 197 patients enrolled in the study with a mean age of 20.94 ± 11.31 years; the majority of them were male. Fuse-detonated noisemakers and homemade grenades were the most frequent causes of injury. Hand injury was reported in 39.8% of the cases. Amputation and long-term disability were found in 6 and 12 cases, respectively. None of the patients died during the study period. The fireworks used during a Chaharshanbe Soori ceremony were responsible for a considerable number of injuries to different parts of the body, and some of them led to permanent disabilities. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Evidence against roles for phorbol binding protein Munc13-1, ADAM adaptor Eve-1, or vesicle trafficking phosphoproteins Munc18 or NSF as phospho-state-sensitive modulators of phorbol/PKC-activated Alzheimer APP ectodomain shedding

    Directory of Open Access Journals (Sweden)

    Lovestone Simon

    2007-12-01

    Full Text Available Abstract Background Shedding of the Alzheimer amyloid precursor protein (APP ectodomain can be accelerated by phorbol esters, compounds that act via protein kinase C (PKC or through unconventional phorbol-binding proteins such as Munc13-1. We have previously demonstrated that application of phorbol esters or purified PKC potentiates budding of APP-bearing secretory vesicles at the trans-Golgi network (TGN and toward the plasma membrane where APP becomes a substrate for enzymes responsible for shedding, known collectively as α-secretase(s. However, molecular identification of the presumptive "phospho-state-sensitive modulators of ectodomain shedding" (PMES responsible for regulated shedding has been challenging. Here, we examined the effects on APP ectodomain shedding of four phorbol-sensitive proteins involved in regulation of vesicular membrane trafficking of APP: Munc13-1, Munc18, NSF, and Eve-1. Results Overexpression of either phorbol-sensitive wildtype Munc13-1 or phorbol-insensitive Munc13-1 H567K resulted in increased basal APP ectodomain shedding. However, in contrast to the report of Roßner et al (2004, phorbol ester-dependent APP ectodomain shedding from cells overexpressing APP and Munc13-1 wildtype was indistinguishable from that observed following application of phorbol to cells overexpressing APP and Munc13-1 H567K mutant. This pattern of similar effects on basal and stimulated APP shedding was also observed for Munc18 and NSF. Eve-1, an ADAM adaptor protein reported to be essential for PKC-regulated shedding of pro-EGF, was found to play no obvious role in regulated shedding of sAPPα. Conclusion Our results indicate that, in the HEK293 system, Munc13-1, Munc18, NSF, and EVE-1 fail to meet essential criteria for identity as PMES for APP.

  1. Evidence against roles for phorbol binding protein Munc13-1, ADAM adaptor Eve-1, or vesicle trafficking phosphoproteins Munc18 or NSF as phospho-state-sensitive modulators of phorbol/PKC-activated Alzheimer APP ectodomain shedding.

    Science.gov (United States)

    Ikin, Annat F; Causevic, Mirsada; Pedrini, Steve; Benson, Lyndsey S; Buxbaum, Joseph D; Suzuki, Toshiharu; Lovestone, Simon; Higashiyama, Shigeki; Mustelin, Tomas; Burgoyne, Robert D; Gandy, Sam

    2007-12-09

    Shedding of the Alzheimer amyloid precursor protein (APP) ectodomain can be accelerated by phorbol esters, compounds that act via protein kinase C (PKC) or through unconventional phorbol-binding proteins such as Munc13-1. We have previously demonstrated that application of phorbol esters or purified PKC potentiates budding of APP-bearing secretory vesicles at the trans-Golgi network (TGN) and toward the plasma membrane where APP becomes a substrate for enzymes responsible for shedding, known collectively as alpha-secretase(s). However, molecular identification of the presumptive "phospho-state-sensitive modulators of ectodomain shedding" (PMES) responsible for regulated shedding has been challenging. Here, we examined the effects on APP ectodomain shedding of four phorbol-sensitive proteins involved in regulation of vesicular membrane trafficking of APP: Munc13-1, Munc18, NSF, and Eve-1. Overexpression of either phorbol-sensitive wildtype Munc13-1 or phorbol-insensitive Munc13-1 H567K resulted in increased basal APP ectodomain shedding. However, in contrast to the report of Rossner et al (2004), phorbol ester-dependent APP ectodomain shedding from cells overexpressing APP and Munc13-1 wildtype was indistinguishable from that observed following application of phorbol to cells overexpressing APP and Munc13-1 H567K mutant. This pattern of similar effects on basal and stimulated APP shedding was also observed for Munc18 and NSF. Eve-1, an ADAM adaptor protein reported to be essential for PKC-regulated shedding of pro-EGF, was found to play no obvious role in regulated shedding of sAPPalpha. Our results indicate that, in the HEK293 system, Munc13-1, Munc18, NSF, and EVE-1 fail to meet essential criteria for identity as PMES for APP.

  2. Allowance officers Russian and Austro-Hungarian armies on the eve of the First World War

    Directory of Open Access Journals (Sweden)

    Alexander P. Abramov

    2016-09-01

    Full Text Available On the basis of historical material provides information on measures of state and military administration on the eve of the First World War to improve the welfare of Russian officers and Austro-Hungary, through various forms of material incentives, which are reflected in the cash payments, promotions, awards and social guarantees. On the basis of archival materials of the study period, open scientific publications and Internet resources there are disclosed the features of the destination of salaries, various allowances and compensations Russian army in comparison to the Austro-Hungarian army, who spoke Russian opponent in the First World War. The author notes that the existing system of money allowances in the Russian army was more advantageous than in the Austro-Hungarian army. However, neither one nor the other could not fully meet the needs of the majority of officers of both armies, entered as opponents in the First World War. One of its major shortcomings, both in Russia and in the Austro-Hungarian Empire, was a wide gap in the amounts of all kinds of money allowances between chief officers, staff officers and generals.

  3. Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software.

    Science.gov (United States)

    Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A

    2015-01-01

    The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring

  4. Eestis toodetud ilu / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2008-01-01

    Valik Eesti väljapanekutest mais 2008 Eesti Näituste Pirita messikeskuses toimunud messilt "Interjöör 2008": OÜ Valley lammastega vaip ja mängumuruga tumbad (disainerid Ruth Vassel, Luule Aasma), istumispadjad (tekstiilikunstnikud Liisa Tomasberg, Liisa Kallam), kõlarid (disainer Aleksandr Gorodenkov, nahatükkidest tumba ja lastemööbel (disainer Ingeborg Ahlberg), iste "Põder" (disainer Sirli Ehari), OÜ Seos jonnipunn-tool (disainer Merike Rehepapp), OÜ Resvok lesimisase "Lazy" (disainer Tõnis Krik)

  5. Ammunition production in the USSR in 20-30 years of 20th century and efficiency of the Red Army in the eve and during of the Great Patriotic War

    Directory of Open Access Journals (Sweden)

    Андрей Николаевич Балыш

    2010-12-01

    Full Text Available The role of Ammunition Industry in connection with action variation at the first part of 20th century is analyzed in the present paper. It is studied how the New Economic Policy (NEP influenced onto the development of ammunition industry and respective branches of heavy industry. For the first time several manufacturing peculiarities of ammunition main elements (by example of ammunition bodies in the eve of the Great Patriotic War are analyzed on the base of archival documents and the role of these peculiarities in fighting efficiency of the Soviet forces during the Second World War is studied.

  6. Väitekiri Itaalia reisikirjadest / Tiina Kirss

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2009-01-01

    Arvustus: Kõvamees, Anneli. Itaalia Eesti reisikirjades: Karl Ristikivi "Itaalia capriccio" ja Aimée Beekmani "Plastmassist südamega madonna". Tallinn : Tallinna Ülikooli Kirjastus, 2008. (Tallinna Ülikooli humanitaarteaduste dissertatsioonid ; 21)

  7. Qualification method for a 1 MGy-tolerant front-end chip designed in 65 nm CMOS for the read-out of remotely operated sensors and actuators during maintenance in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens, E-mail: jens.verbeeck@esat.kuleuven.be [KU Leuven (KUL), Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Cao, Ying [KU Leuven (KUL), Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Van Uffelen, Marco; Casellas, Laura Mont; Damiani, Carlo; Morales, Emilio Ruiz; Santana, Roberto Ranz [Fusion for Energy (F4E), c/Josep, no. 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Meek, Richard; Haist, Bernhard [Oxford Technologies Ltd. (OTL), 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Hamilton, David [ITER Organisation (IO), Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul les Durance Cedex (France); Steyaert, Michiel [KU Leuven, ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KU Leuven, ESAT, Advanced Integrated Sensing Lab (AdvISe), Kleinhoefstraat 4, 2440 Geel (Belgium)

    2015-10-15

    This paper describes the radiation qualification procedure for a 1 MGy-tolerant Application Specific Integrated Circuit (ASIC) developed in 65 nm CMOS technology. The chip is intended for the read-out of electrical signals of sensors and actuators during maintenance in ITER. First the general working principle of the ASIC is shown. The developed IC allows to read-out, condition and digitize multiple low bandwidth (<10 kHz) sensors. In addition the IC is able to multiplex the digitized sensor signals. To comply with ITER-relevant constraints an adapted radiation qualification procedure has been proposed. The radiation-qualification procedure describes the test criteria and test conditions of the developed ASICs, which are also compared with COTS alternatives, to meet the stringent qualification procedures for electronics exposed to radiation in ITER.

  8. Aggregation server for grid-integrated vehicles

    Science.gov (United States)

    Kempton, Willett

    2015-05-26

    Methods, systems, and apparatus for aggregating electric power flow between an electric grid and electric vehicles are disclosed. An apparatus for aggregating power flow may include a memory and a processor coupled to the memory to receive electric vehicle equipment (EVE) attributes from a plurality of EVEs, aggregate EVE attributes, predict total available capacity based on the EVE attributes, and dispatch at least a portion of the total available capacity to the grid. Power flow may be aggregated by receiving EVE operational parameters from each EVE, aggregating the received EVE operational parameters, predicting total available capacity based on the aggregated EVE operational parameters, and dispatching at least a portion of the total available capacity to the grid.

  9. From nGy to MGy - new TL dosimetry of complex radiation at high-energy accelerators and thermonuclear fusion facilities

    International Nuclear Information System (INIS)

    Obryk, B.; Bilski, P.; Budzanowski, M.; Olko, P.

    2011-01-01

    One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nano grays up to a few kilo grays, when the total saturation of the signal of the so-called main dosimetric peak (at about 220 C. degrees) occurs. In 2006 for the first time we observed unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 C. degrees, after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the high temperature coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and in high-energy mixed fields around the SPS and PS accelerators at CERN. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators and has great potential for accident dosimetry in particular. (authors)

  10. Electric vehicle station equipment for grid-integrated vehicles

    Science.gov (United States)

    Kempton, Willett; Kiamilev, Fouad; McGee, Rodney; Waite, Nick

    2017-09-05

    Methods, systems, and apparatus transferring power between the grid and an electric vehicle are disclosed. The apparatus may include at least one vehicle communication port for interfacing with electric vehicle equipment (EVE) and a processor coupled to the at least one vehicle communication port to establish communication with the EVE, receive EVE attributes from the EVE, and transmit electric vehicle station equipment (EVSE) attributes to the EVE. Power may be transferred between the grid and the electric vehicle by maintaining EVSE attributes, establishing communication with the EVE, and transmitting the EVSE maintained attributes to the EVE.

  11. Steni muinasjutuvõistluse võitjad selgunud / Ants Roos, Ann Roos

    Index Scriptorium Estoniae

    Roos, Ants

    2008-01-01

    Steni XVI muinasjutuvõistluse žüriisse kuulusid: Ann Roos, Ants Roos, Leelo Tungal, Krista Kumberg, Leida Olszak, Ülle Väljataga. Tulemused: I koht Siim Niinelaid, II koht Julius Air Kull, III koht Mihkel Rammu. Žürii eriauhinnad: Anna Kristin Peterson, Elis Ruus, Rain Hallikas, Mariliis Peterson, Marjaliisa Palu, Karl Kirsimäe, Margaret Pulk. Ergutusauhinnad: Karmel Klaus, Martti Kaljuste, Kristina Korell, Mirjam Võsaste, Mihkel Põder, Iirys Kalde, Miriam Jamul, Mari-Ann Mägi, Ketlin Saar, Liisbeth Kirss. Muud eriauhinnad said: Allan Läll, Berle Mees, Anett Kuuse, Karl Erik Kübarsepp, Grete Tamm, Siim Niinelaid, Kaisa Marie Sipelgas, Ellen Anett Põldmaa, Evelin Laul, Karl Laas, Karl Stamm, Kerli Retter

  12. THE FOREIGN POLICY OF THE BOLSHEVIKS ON THE EVE OF THE PARIS PEACE CONFERENCE OF 1919

    Directory of Open Access Journals (Sweden)

    Elena Nikolaevna Emelyanova

    2017-11-01

    Full Text Available Purpose. The article examines the foreign policy activities of the Bolshevik leadership on the eve of the opening of the Paris Peace Conference. The strategy and tactics of the RCP (B in the autumn-winter of 1918–1919 are analyzed, as well as the attempt to establish relations with the great powers hostile to the RSFSR, the striving of Soviet Russia to take its place in the new Versailles system. The ways to achieve this goal are exploring. The methodological basis of the article are the principles of objectivity, historicism, a critical approach to the sources used and a comprehensive analysis of the problem posed. Results: it is argued that the international situation, the growth of the revolutionary movement in Europe in 1918–1919, the unification of all left-wing forces around the Soviet state forced the leaders of Britain and the US to send their representative for talks with the Bolsheviks. On the other hand, the Bolshevik leadership sought to reach agreement with the world powers on recognizing the Soviet government, even by temporarily abandoning international goals, the implementation of these tasks was delegated to the Communist International created in March 1919. The preservation of the Soviet state was put by the Bolsheviks above the idea of a “world revolution”. Scope of application of the results. The results of the work can be used for further research in the field of history and political science, as well as in the teaching of these disciplines in the university.

  13. Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China Jinping Underground Laboratory

    Science.gov (United States)

    Yang, Li-Tao; Li, Hau-Bin; Yue, Qian; Kang, Ke-Jun; Cheng, Jian-Ping; Li, Yuan-Jing; Tsz-King Wong, Henry; Aǧartioǧlu, M.; An, Hai-Peng; Chang, Jian-Ping; Chen, Jing-Han; Chen, Yun-Hua; Deng, Zhi; Du, Qiang; Gong, Hui; He, Li; Hu, Jin-Wei; Hu, Qing-Dong; Huang, Han-Xiong; Jia, Li-Ping; Jiang, Hao; Li, Hong; Li, Jian-Min; Li, Jin; Li, Xia; Li, Xue-Qian; Li, Yu-Lan; Lin, Fong-Kay; Lin, Shin-Ted; Liu, Shu-Kui; Liu, Zhong-Zhi; Ma, Hao; Ma, Jing-Lu; Pan, Hui; Ren, Jie; Ruan, Xi-Chao; Sevda, B.; Sharma, Vivek; Shen, Man-Bin; Singh, Lakhwinder; Singh, Manoj Kumar; Tang, Chang-Jian; Tang, Wei-You; Tian, Yang; Wang, Ji-Min; Wang, Li; Wang, Qing; Wang, Yi; Wu, Shi-Yong; Wu, Yu-Cheng; Xing, Hao-Yang; Xu, Yin; Xue, Tao; Yang, Song-Wei; Yi, Nan; Yu, Chun-Xu; Yu, Hai-Jun; Yue, Jian-Feng; Zeng, Xiong-Hui; Zeng, Ming; Zeng, Zhi; Zhang, Yun-Hua; Zhao, Ming-Gang; Zhao, Wei; Zhou, Ji-Fang; Zhou, Zu-Ying; Zhu, Jing-Jun; Zhu, Zhong-Hua; CDEX Collaboration

    2018-01-01

    We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV. Supported by the National Key Research and Development Program of China (2017YFA0402200, 2017YFA0402201), the National Natural Science Foundation of China (11175099, 11275107, 11475117, 11475099, 11475092, 11675088), the National Basic Research Program of China (973 Program) (2010CB833006). We thank the support of grants from the Tsinghua University Initiative Scientific Research Program (20121088494, 20151080354) and the Academia Sinica Investigator Award 2011-15, contracts 103-2112-M-001-024 and 104-2112-M-001-038-MY3 from the Ministry of Science and Technology of Taiwan.

  14. Kõik mehed on vist sead? / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2003-01-01

    Arvustus: O'Brien, Edna. Maatüdrukud : [romaan] / tõlkinud [ja järelsõna:] Sirje Leol. Tallinn : Eesti Raamat, c2002 ; O'Brien, Edna. Üksildane tüdruk : [triloogia 2. osa] ; Tüdrukud abielutaevas : [triloogia 3. osa] / tõlkinud Sirje Leol. Tallinn : Eesti Raamat, 2003

  15. Adam, Eve and the reflux enigma: age and sex differences across the gastro-oesophageal reflux spectrum.

    Science.gov (United States)

    Royston, Christine; Bardhan, Karna D

    2017-06-01

    We present demographic differences across the gastro-oesophageal reflux disease (GORD) spectrum in a UK District General Hospital. Data were prospectively collected over 37 years. At endoscopy patients were categorized as: erosive oesophagitis (EO), Barrett's oesophagus (BO) or nonerosive reflux disease (NER). Analysis 1: comparison of EO, BO and NER 1977-2001 when the database for GORD without BO closed. Analysis 2: demographic differences in oesophageal adenocarcinoma (OAC) in total BO population diagnosed 1977-2011. GORD 1977-2001 (n=11 944): sex, male predominance in EO and BO but not NER; male : female ratios, 1.81, 1.65, 0.87, respectively (P<0.0001); mean age at presentation, EO 54 years, BO 62 years, NER 50 years; women were older than men by 10, 7 and 6 years, respectively.BO 1977-2011: prevalent OAC, 87/1468 (6%); male : female ratio, 4.1 (P<0.0001); incident OAC, 54/1381 (3.9%); male : female ratio, 3.5 (P<0.0001). Among all BO, more men developed OAC (3 vs. 0.9%). Within each sex, proportion of OAC higher among men (4.9 vs. 2.3%); at OAC diagnosis women were slightly but not significantly older (69.9 vs. 72.3 years, P=0.322). Two views may explain our findings. First, women have either milder reflux, or reduced mucosal sensitivity hence reflux remains silent for longer. Alternatively, women genuinely develop reflux later, that is, are more protected and for longer from developing GORD and its complications. Early evidence is emerging that female sex hormones may indeed have a protective role in GORD during the reproductive period. We suggest reflux and its consequences may be an example of 'protection' conferred on Eve.

  16. Optimization of Monocrystalline MgxCd1-xTe/MgyCd1-yTe Double-Heterostructure Solar Cells

    Science.gov (United States)

    Becker, Jacob J.

    Polycrystalline CdS/CdTe solar cells continue to dominate the thin-film photovoltaics industry with an achieved record efficiency of over 22% demonstrated by First Solar, yet monocrystalline CdTe devices have received considerably less attention over the years. Monocrystalline CdTe double-heterostructure solar cells show great promise with respect to addressing the problem of low Voc with the passing of the 1 V benchmark. Rapid progress has been made in driving the efficiency in these devices ever closer to the record presently held by polycrystalline thin-films. This achievement is primarily due to the utilization of a remote p-n heterojunction in which the heavily doped contact materials, which are so problematic in terms of increasing non-radiative recombination inside the absorber, are moved outside of the CdTe double heterostructure with two MgyCd1-yTe barrier layers to provide confinement and passivation at the CdTe surfaces. Using this design, the pursuit and demonstration of efficiencies beyond 20% in CdTe solar cells is reported through the study and optimization of the structure barriers, contacts layers, and optical design. Further development of a wider bandgap MgxCd1-xTe solar cell based on the same design is included with the intention of applying this knowledge to the development of a tandem solar cell constructed on a silicon subcell. The exploration of different hole-contact materials--ZnTe, CuZnS, and a-Si:H--and their optimization is presented throughout the work. Devices utilizing a-Si:H hole contacts exhibit open-circuit voltages of up to 1.11 V, a maximum total-area efficiency of 18.5% measured under AM1.5G, and an active-area efficiency of 20.3% for CdTe absorber based devices. The achievement of voltages beyond 1.1V while still maintaining relatively high fill factors with no rollover, either before or after open-circuit, is a promising indicator that this approach can result in devices surpassing the 22% record set by polycrystalline

  17. ["Should the staff's attitude towards the patients remain unchanged, I will not guarantee anything." Protest masculinity and coping of "rebellious patients" at the Heidelberg University Psychiatric Hospital on the eve of deinstitutionalization].

    Science.gov (United States)

    Schwamm, Christoph

    2015-01-01

    This article analyses the illness experiences of male patients from the Heidelberg University Psychiatric Hospital during the protests against Psychiatry in the year 1973. Protest is one of the most important expressions of masculinity in socially disadvantaged men, such as men with mental disorders. The analysis of 100 medical records shows that some patients tried to construct themselves as men in a way that was explicitly motivated by antipsychiatric ideas: They questioned psychiatric authority, behaved "sexually inappropriate", or used drugs. On the eve of psychiatric reform in West Germany those patients were well aware that the alternative--complying with the treatment--would put them at considerable risk. In addition to the usual inference of hegemonic or normative masculinities as risk-factors, the behavior of those ,,rebellious patients" has to be interpreted as individual coping strategies.

  18. Dose intensity and efficacy of the combination of everolimus and exemestane (EVE/EXE) in a real-world population of hormone receptor-positive (ER+/PgR+), HER2-negative advanced breast cancer (ABC) patients: a multicenter Italian experience.

    Science.gov (United States)

    Ciccarese, Mariangela; Fabi, Alessandra; Moscetti, Luca; Cazzaniga, Maria Elena; Petrucelli, Luciana; Forcignanò, Rosachiara; Lupo, Laura Isabella; De Matteis, Elisabetta; Chiuri, Vincenzo Emanuele; Cairo, Giuseppe; Febbraro, Antonio; Giordano, Guido; Giampaglia, Marianna; Bilancia, Domenico; La Verde, Nicla; Maiello, Evaristo; Morritti, Maria; Giotta, Francesco; Lorusso, Vito; Latorre, Agnese; Scavelli, Claudio; Romito, Sante; Cusmai, Antonio; Palmiotti, Gennaro; Surico, Giammarco

    2017-06-01

    This retrospective analysis focused on the effect of treatment with EVE/EXE in a real-world population outside of clinical trials. We examined the efficacy of this combination in terms of PFS and RR related to dose intensity (5 mg daily versus 10 mg daily) and tolerability. 163 HER2-negative ER+/PgR+ ABC patients, treated with EVE/EXE from May 2011 to March 2016, were included in the analysis. The primary endpoints were the correlation between the daily dose and RR and PFS, as well as an evaluation of the tolerability of the combination. Secondary endpoints were RR, PFS, and OS according to the line of treatment. Patients were classified into three different groups, each with a different dose intensity of everolimus (A, B, C). RR was 29.8% (A), 27.8% (B) (p = 0.953), and not evaluable (C). PFS was 9 months (95% CI 7-11) (A), 10 months (95% CI 9-11) (B), and 5 months (95% CI 2-8) (C), p = 0.956. OS was 38 months (95% CI 24-38) (A), median not reached (B), and 13 months (95% CI 10-25) (C), p = 0.002. Adverse events were stomatitis 57.7% (11.0% grade 3-4), asthenia 46.0% (6.1% grade 3-4), hypercholesterolemia 46.0% (0.6% grade 3-4), and hyperglycemia 35.6% (5.5% grade 3-4). The main reason for discontinuation/interruption was grade 2-3 stomatitis. No correlation was found between dose intensity (5 vs. 10 mg labeled dose) and efficacy in terms of RR and PFS. The tolerability of the higher dose was poor in our experience, although this had no impact on efficacy.

  19. Anomalous Temporal Behaviour of Broadband Ly Alpha Observations During Solar Flares from SDO/EVE

    Science.gov (United States)

    Milligan, Ryan O.; Chamberlin, Phillip C.

    2016-01-01

    Although it is the most prominent emission line in the solar spectrum, there has been a notable lack of studies devoted to variations in Lyman-alpha (Ly-alpha) emission during solar flares in recent years. However, the few examples that do exist have shown Ly-alpha emission to be a substantial radiator of the total energy budget of solar flares (of the order of 10 percent). It is also a known driver of fluctuations in the Earth's ionosphere. The EUV (Extreme Ultra-Violet) Variability Experiment (EVE) on board the Solar Dynamics Observatory (SDO) now provides broadband, photometric Ly-alpha data at 10-second cadence with its Multiple EUV Grating Spectrograph-Photometer (MEGS-P) component, and has observed scores of solar flares in the 5 years since it was launched. However, the MEGS-P time profiles appear to display a rise time of tens of minutes around the time of the flare onset. This is in stark contrast to the rapid, impulsive increase observed in other intrinsically chromospheric features (H-alpha, Ly-beta, LyC, C III, etc.). Furthermore, the emission detected by MEGS-P peaks around the time of the peak of thermal soft X-ray emission and not during the impulsive phase when energy deposition in the chromosphere (often assumed to be in the form of non-thermal electrons) is greatest. The time derivative of Ly-alpha lightcurves also appears to resemble that of the time derivative of soft X-rays, reminiscent of the Neupert effect. Given that spectrally-resolved Ly-alpha observations during flares from SORCE / SOLSTICE (Solar Radiation and Climate Experiment / Solar Stellar Irradiance Comparison Experiment) peak during the impulsive phase as expected, this suggests that the atypical behaviour of MEGS-P data is a manifestation of the broadband nature of the observations. This could imply that other lines andor continuum emission that becomes enhanced during flares could be contributing to the passband. Users are hereby urged to exercise caution when interpreting

  20. Spectroscopic Diagnostics of the Non-Maxwellian κ-distributions Using SDO/EVE Observations of the 2012 March 7 X-class Flare

    Science.gov (United States)

    Dzifčáková, Elena; Zemanová, Alena; Dudík, Jaroslav; Mackovjak, Šimon

    2018-02-01

    Spectroscopic observations made by the Extreme Ultraviolet Variability Experiment (EVE) on board the Solar Dynamics Observatory (SDO) during the 2012 March 7 X5.4-class flare (SOL2012-03-07T00:07) are analyzed for signatures of the non-Maxwellian κ-distributions. Observed spectra were averaged over 1 minute to increase photon statistics in weaker lines and the pre-flare spectrum was subtracted. Synthetic line intensities for the κ-distributions are calculated using the KAPPA database. We find strong departures (κ ≲ 2) during the early and impulsive phases of the flare, with subsequent thermalization of the flare plasma during the gradual phase. If the temperatures are diagnosed from a single line ratio, the results are strongly dependent on the value of κ. For κ = 2, we find temperatures about a factor of two higher than the commonly used Maxwellian ones. The non-Maxwellian effects could also cause the temperatures diagnosed from line ratios and from the ratio of GOES X-ray channels to be different. Multithermal analysis reveals the plasma to be strongly multithermal at all times with flat DEMs. For lower κ, the {{DEM}}κ are shifted toward higher temperatures. The only parameter that is nearly independent of κ is electron density, where we find log({n}{{e}} [{{cm}}-3]) ≈ 11.5 almost independently of time. We conclude that the non-Maxwellian effects are important and should be taken into account when analyzing solar flare observations, including spectroscopic and imaging ones.

  1. The Multi-Instrument (EVE-RHESSI) DEM for Solar Flares, and Implications for Residual Non-Thermal Soft X-Ray Emission

    Science.gov (United States)

    McTiernan, James M.; Caspi, Amir; Warren, Harry

    2015-04-01

    In the soft X-ray energy range, solar flare spectra are typically dominated by thermal emission. The low energy extent of non-thermal emission can only be loosely quantified using currently available X-ray data. To address this issue, we combine observations from the EUV Variability Experiment (EVE) on-board the Solar Dynamics Observatory (SDO) with X-ray data from the Reuven Ramaty High Energy Spectroscopic Imager (RHESSI). The improvement over the isothermal approximation is intended to resolve the ambiguity in the range where the thermal and non-thermal components may have similar photon fluxes. This "crossover" range can extend up to 30 keV for medium to large solar flares.Previous work (Caspi et.al. 2014ApJ...788L..31C) has concentrated on obtaining DEM models that fit both instruments' observations well. Now we are interested in any breaks and cutoffs in the "residual" non-thermal spectrum; i.e., the RHESSI spectrum that is left over after the DEM has accounted for the bulk of the soft X-ray emission. Thermal emission is again modeled using a DEM that is parametrized as multiple gaussians in temperature; the non-thermal emission is modeled as a photon spectrum obtained using a thin-target emission model ('thin2' from the SolarSoft Xray IDL package). Spectra for both instruments are fit simultaneously in a self-consistent manner. The results for non-thermal parameters then are compared with those found using RHESSI data alone, with isothermal and double-thermal models.

  2. Rändavad piirid : postkolonialismi võimalused / Tiina Kirss

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2001-01-01

    Postkolonialism: interdistsiplinaarne uurimissuund, mis tegeleb peamiselt "kolmanda maailma" pärisrahvaste kirjanduste ja kultuuridega. Ka postkolonialismi uurimismeetodite kasutamise võimalustest eesti kirjandusteaduses

  3. Three Women in Quest of Narrative / Tiina Kirss

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2008-01-01

    Epp Annuse romaanist "Sina, Matilda" (Tallinn : Tuum, 2007), Kärt Hellermaa novellikogust "Ma armastasin David Copperfieldi" (Tallinn : Tuum, 2007) ja Kristiina Ehini lühiproosakogust "Pillipuhujanaine ja pommipanijanaine" (Tallinn : Huma, 2006)

  4. How calibration and reference spectra affect the accuracy of absolute soft X-ray solar irradiance measured by the SDO/EVE/ESP during high solar activity

    Science.gov (United States)

    Didkovsky, Leonid; Wieman, Seth; Woods, Thomas

    2016-10-01

    The Extreme ultraviolet Spectrophotometer (ESP), one of the channels of SDO's Extreme ultraviolet Variability Experiment (EVE), measures solar irradiance in several EUV and soft x-ray (SXR) bands isolated using thin-film filters and a transmission diffraction grating, and includes a quad-diode detector positioned at the grating zeroth-order to observe in a wavelength band from about 0.1 to 7.0 nm. The quad diode signal also includes some contribution from shorter wavelength in the grating's first-order and the ratio of zeroth-order to first-order signal depends on both source geometry, and spectral distribution. For example, radiometric calibration of the ESP zeroth-order at the NIST SURF BL-2 with a near-parallel beam provides a different zeroth-to-first-order ratio than modeled for solar observations. The relative influence of "uncalibrated" first-order irradiance during solar observations is a function of the solar spectral irradiance and the locations of large Active Regions or solar flares. We discuss how the "uncalibrated" first-order "solar" component and the use of variable solar reference spectra affect determination of absolute SXR irradiance which currently may be significantly overestimated during high solar activity.

  5. Kurumsal Sürdürülebilirlik Performansının Ölçümü İçin Çok Kriterli Bir Çerçeve: Henkel Örneği

    OpenAIRE

    Ahmet Öztel; Mehmet Said Köse; İhsan Aytekin

    2012-01-01

    Kurumsal sürdürülebilirlik performans ölçümü, kurumsal sürdürülebilirliğin çevresel, sosyal ve ekonomik yönlerini ele almayı amaçlamaktadır. Bu üç boyutun tek bir boyuta indirgenmesinde sorunlar ortaya çıkmaktadır. Çok kriterli karar verme yöntemleri, bu değişkenlerin birlikte değerlendirilmesi için kullanışlı bir çerçeve sunmaktadır. Bu çalışmada, çok kriterli karar verme yöntemlerinden uzlaşık programlama (compromise programing) çerçevesi kullanılarak Henkel firmasının kurumsal sürdürülebil...

  6. Real-world effectiveness of everolimus-based therapy versus fulvestrant monotherapy in HR(+)/HER2(-) metastatic breast cancer.

    Science.gov (United States)

    Hao, Yanni; Lin, Peggy L; Xie, Jipan; Li, Nanxin; Koo, Valerie; Ohashi, Erika; Wu, Eric Q; Rogerio, Jaqueline

    2015-08-01

    Assessing real-world effectiveness of everolimus-based therapy (EVE) versus fulvestrant monotherapy (FUL) among postmenopausal women with hormone receptor-positive (HR(+))/HER2(-) metastatic breast cancer (mBC) after progression on nonsteroidal aromatase inhibitor (NSAI). Medical charts of community-based patients who received EVE or FUL for mBC after NSAI were examined. Progression-free survival (PFS), time on treatment and time to chemotherapy were compared using Kaplan-Meier curves and Cox proportional hazards models adjusting for line of therapy and patient characteristics. 192 patients received EVE and 156 FUL. After adjusting for patient characteristics, EVE was associated with significantly longer PFS than FUL (hazard ratio: 0.71; p = 0.045). EVE was associated with better PFS than FUL among NSAI-refractory postmenopausal HR(+)/HER2(-) mBC patients.

  7. Adult exposures from MDCT including multiphase studies: first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Palorini, Federica; Origgi, Daniela [Fisica Sanitaria Istituto Europeo di Oncologia, Milan (Italy); Granata, Claudio [UOC di Radiologia Istituto Giannina Gaslini, Genoa (Italy); Matranga, Domenica [Universita degli Studi di Palermo, Dipartimento di Scienze per la Promozione della Salute e Materno-infantile ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [Policlinico Universita di Palermo, Dipartimento di Scienze Radiologiche, Palermo (Italy)

    2014-02-15

    To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population. This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest-abdomen-pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDI{sub vol}) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure. The 75th percentiles of CTDI{sub vol} (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm, respectively; for chest, 15 mGy and 569 mGy cm; spine, 42 mGy and 888 mGy cm; cardiac, 7 mGy and 131 mGy cm for calcium score, and 61 mGy and 1,208 mGy cm for angiographic CT studies. High variability was present in the DLP of abdomen and CAP protocols, where multiphase examinations dominated (71 % and 73 % respectively): for abdomen, 18 mGy, with 555 and 920 mGy cm in abdomen and abdomen-pelvis acquisitions respectively; for CAP, 17 mGy, with 508, 850 and 1,200 mGy cm in abdomen, abdomen-pelvis and CAP acquisitions respectively. The results of this survey could help in the definition of updated diagnostic reference levels (DRL). (orig.)

  8. The Role of Racial Discrimination in the Economic Value of Education Among Urban, Low-Income Latina/o Youth: Ethnic Identity and Gender as Moderators.

    Science.gov (United States)

    Mroczkowski, Alison L; Sánchez, Bernadette

    2015-09-01

    The present study used resilience theory to explore relationships among perceived racial discrimination, ethnic identity, gender, and economic value of education (EVE) among urban, low-income, Latina/o youth. It was expected that racial discrimination would predict poorer perceptions of the EVE among Latina/o adolescents. Ethnic identity was hypothesized to buffer the negative effect of racial discrimination on Latina/o students' EVE. The participants in this study were 396 urban, low-income Latina/o high school students from a large, Midwestern city who completed surveys in both 9th- and 10th-grade. Structural equation modeling was used to test the relationships among racial discrimination, ethnic identity, and EVE. Results supported a protective model of resilience. Specifically, ethnic identity served as a protective factor by buffering the negative effect of perceived racial discrimination on EVE for male participants. The present study is the first to examine ethnic identity as a buffer of racial discrimination on EVE among Latina/o high school students. Future directions and implications are discussed.

  9. As-Deposited (La1-xSrx)(Ga1-y-zMgyCoz)O3-(x+y+z)/2 Crystallized Thin Films Prepared by Pulsed Laser Deposition for Application to Solid Oxide Fuel Cell Electrolyte

    Science.gov (United States)

    Mitsugi, Fumiaki; Kanazawa, Seiji; Ohkubo, Toshikazu; Nomoto, Yukiharu; Ishihara, Tatsumi; Takita, Yusaku

    2004-01-01

    Doped lanthanum gallate (La1-xSrx)(Ga1-y-zMgyCoz)O3-(x+y+z)/2 (LSGMCO) perovskite oxide films were deposited on a quartz glass, LaAlO3 single-crystal substrate and porous anode electrode of a solid oxide fuel cell (SOFC) by pulsed laser deposition. It was necessary to increase the substrate temperature up to 800°C for a crystallization of the LSGMCO films. The film deposited on the LaAlO3 single-crystal substrate grew along the c-axis. The as-deposited LSGMCO thick film fabricated on the porous substrate at 800°C and at an oxygen pressure of 20Pa was formed from polycrystal columns and showed a high conductivity of 0.7S/cm at a measurement temperature of 800°C. The activation energies were 0.72 eV at 600-800°C and 1.05 eV at 400-600°C.

  10. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  11. A survey of patients dose management in computed tomography with special emphasis to paetriatric patients in Ghana

    International Nuclear Information System (INIS)

    Inkoon, S.; Emi-Reynolds, G.; Boadu, M.; Schandorf, C.

    2010-01-01

    A survey of the frequency of common computed tomography (CT) examinations and the doses of six (6) CT facilities in Ghana has been undertaken. The technique factors for both adult and paediatric examinations were assessed. The dosimetric parameter used was the weighted computerized tomography dose index (CTDIw) for a single slice and the dose length product (DLP) for complete CT examinations of chest, chest high resolution (HR), lumbar spine, abdomen and pelvis. The effective dose (E) was estimated to give the stochastic radiation risk of a non-uniform exposure in terms of a whole body exposure. It was observed that some facilities used the same adult CT technique factors for paediatric patients. Mean values of adult CTDIw ranged as: chest (7.1-29.7 mGy), chest HR (7.1-30.0 mGy), lumbar spine (13.4-42.4 mGy), abdomen (7.8-42.4 mGy) and pelvis (8.9-42.4 mGy). Mean paediatric CTDIw values ranged as: chest (6.4-29.7 mGy), chest HR (6.4-30.0 mGy), lumbar spine (10.1-42.4 mGy), abdomen (10.1-42.4 mGy) and pelvis (10.1-42.4 mGy). The mean adult DLP values ranged as: chest (178-594 mGy cm), chest HR (168-594 mGy cm), lumbar spine (287-848 mGy cm), abdomen (233-848 mGy cm) and pelvis (228-848 mGy cm). However the mean paediatric DLP values ranged as: chest (128-594 mGy cm), chest HR (113-594 mGy cm), lumbar spine (253-848 mGy cm), abdomen (146-848 mGy cm) and pelvis (202-848 mGy cm). The E values for adults ranged as follows: chest (3.0-10.1 mSv), chest HR (2.9-10.1 mSv), lumbar spine (4.3-12.7 mSv), abdomen (3.5-12.7 mSv) and pelvis (4.3-12.7 mSv). The results show some agreement with diagnostic reference levels of CTDIw DLP and E values from literature. Nevertheless, further optimisation studies are needed to further reduce patient doses and modifications of technique factors especially for paediatrics (author)

  12. Sex differences in interactions between nucleus accumbens and visual cortex by explicit visual erotic stimuli: an fMRI study.

    Science.gov (United States)

    Lee, S W; Jeong, B S; Choi, J; Kim, J-W

    2015-01-01

    Men tend to have greater positive responses than women to explicit visual erotic stimuli (EVES). However, it remains unclear, which brain network makes men more sensitive to EVES and which factors contribute to the brain network activity. In this study, we aimed to assess the effect of sex difference on brain connectivity patterns by EVES. We also investigated the association of testosterone with brain connection that showed the effects of sex difference. During functional magnetic resonance imaging scans, 14 males and 14 females were asked to see alternating blocks of pictures that were either erotic or non-erotic. Psychophysiological interaction analysis was performed to investigate the functional connectivity of the nucleus accumbens (NA) as it related to EVES. Men showed significantly greater EVES-specific functional connection between the right NA and the right lateral occipital cortex (LOC). In addition, the right NA and the right LOC network activity was positively correlated with the plasma testosterone level in men. Our results suggest that the reason men are sensitive to EVES is the increased interaction in the visual reward networks, which is modulated by their plasma testosterone level.

  13. Expression of the pair-rule gene homologs runt, Pax3/7, even-skipped-1 and even-skipped-2 during larval and juvenile development of the polychaete annelid Capitella teleta does not support a role in segmentation

    Directory of Open Access Journals (Sweden)

    Seaver Elaine C

    2012-04-01

    Full Text Available Abstract Background Annelids and arthropods each possess a segmented body. Whether this similarity represents an evolutionary convergence or inheritance from a common segmented ancestor is the subject of ongoing investigation. Methods To investigate whether annelids and arthropods share molecular components that control segmentation, we isolated orthologs of the Drosophila melanogaster pair-rule genes, runt, paired (Pax3/7 and eve, from the polychaete annelid Capitella teleta and used whole mount in situ hybridization to characterize their expression patterns. Results When segments first appear, expression of the single C. teleta runt ortholog is only detected in the brain. Later, Ct-runt is expressed in the ventral nerve cord, foregut and hindgut. Analysis of Pax genes in the C. teleta genome reveals the presence of a single Pax3/7 ortholog. Ct-Pax3/7 is initially detected in the mid-body prior to segmentation, but is restricted to two longitudinal bands in the ventral ectoderm. Each of the two C. teleta eve orthologs has a unique and complex expression pattern, although there is partial overlap in several tissues. Prior to and during segment formation, Ct-eve1 and Ct-eve2 are both expressed in the bilaterial pair of mesoteloblasts, while Ct-eve1 is expressed in the descendant mesodermal band cells. At later stages, Ct-eve2 is expressed in the central and peripheral nervous system, and in mesoderm along the dorsal midline. In late stage larvae and adults, Ct-eve1 and Ct-eve2 are expressed in the posterior growth zone. Conclusions C. teleta eve, Pax3/7 and runt homologs all have distinct expression patterns and share expression domains with homologs from other bilaterians. None of the pair-rule orthologs examined in C. teleta exhibit segmental or pair-rule stripes of expression in the ectoderm or mesoderm, consistent with an independent origin of segmentation between annelids and arthropods.

  14. In situ X-ray and neutron diffraction of the Ruddlesden-Popper compounds (RE2-xSrx)0.98(Fe0.8Co0.2)1-yMgyO4-δ (RE=La, Pr): Structure and CO2 stability

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Hauback, B.C.; Hendriksen, Peter Vang

    2013-01-01

    The crystal structure of the Ruddlesden-Popper compounds (La 1.0Sr1.0)0.98Fe0.8Co 0.2O4-δ and (La1.2Sr0.8) 0.98(Fe0.8Co0.2)0.8Mg 0.2O4-δ was investigated at 1000 °C in N 2 (aO2=1×10-4) by in-situ powder neutron diffraction. In-situ powder X-ray diffraction (PXD) was also employed to investigate....... The equivalent pseudo-cubic thermal and chemical expansion coefficients are in agreement with values determined by dilatometry. The chemical stability in CO2 containing environments of various Ruddlesden-Popper compounds with chemical formula (RE2-xSr x)0.98(Fe0.8Co0.2) 1-yMgyO4-δ (RE=La, Pr), as well...

  15. Specific considerations for obtaining appropriate La1-xSrxGa1-yMgyO3-δ thin films using pulsed-laser deposition and its influence on the performance of solid-oxide fuel cells

    Science.gov (United States)

    Hwang, Jaeyeon; Lee, Heon; Lee, Jong-Ho; Yoon, Kyung Joong; Kim, Hyoungchul; Hong, Jongsup; Son, Ji-Won

    2015-01-01

    To obtain La1-xSrxGa1-yMgyO3-δ (LSGM) thin films with the appropriate properties, pulsed-laser deposition (PLD) is employed, and specific considerations regarding control of the deposition parameters is investigated. It is demonstrated that with a target of stoichiometric composition, appropriate LSGM thin films cannot be produced because of the deviation of the composition from the target to the thin film. Only after adjusting the target composition an LSGM thin film with an appropriate composition and phase can be obtained. The optimized LSGM thin film possesses an electrical conductivity close to that of the bulk LSGM. In contrast, non-optimized thin films do not yield any measurable electrical conductivity. The impact of the optimization of the LSGM thin-film electrolyte on the cell performance is quite significant, in that a solid-oxide fuel cell (SOFC) with an optimized LSGM thin-film electrolyte produces a maximum power density of 1.1 W cm-2 at 600 °C, whereas an SOFC with a non-optimal LSGM thin-film electrolyte is not operable.

  16. Safety and efficacy of everolimus with exemestane vs. exemestane alone in elderly patients with HER2-negative, hormone receptor-positive breast cancer in BOLERO-2.

    Science.gov (United States)

    Pritchard, Kathleen I; Burris, Howard A; Ito, Yoshinori; Rugo, Hope S; Dakhil, Shaker; Hortobagyi, Gabriel N; Campone, Mario; Csöszi, Tibor; Baselga, José; Puttawibul, Puttisak; Piccart, Martine; Heng, Daniel; Noguchi, Shinzaburo; Srimuninnimit, Vichien; Bourgeois, Hugues; Gonzalez Martin, Antonio; Osborne, Karen; Panneerselvam, Ashok; Taran, Tetiana; Sahmoud, Tarek; Gnant, Michael

    2013-12-01

    Postmenopausal women with hormone receptor-positive (HR(+)) breast cancer in whom disease progresses or there is recurrence while taking a nonsteroidal aromatase inhibitor (NSAI) are usually treated with exemestane (EXE), but no single standard of care exists in this setting. The BOLERO-2 trial demonstrated that adding everolimus (EVE) to EXE improved progression-free survival (PFS) while maintaining quality of life when compared with EXE alone. Because many women with HR(+) advanced breast cancer are elderly, the tolerability profile of EVE plus EXE in this population is of interest. BOLERO-2, a phase III randomized trial, compared EVE (10 mg/d) and placebo (PBO), both plus EXE (25 mg/d), in 724 postmenopausal women with HR(+) advanced breast cancer recurring/progressing after treatment with NSAIs. Safety and efficacy data in elderly patients are reported at 18-month median follow-up. Baseline disease characteristics and treatment histories among the elderly subsets (≥ 65 years, n = 275; ≥ 70 years, n = 164) were generally comparable with younger patients. The addition of EVE to EXE improved PFS regardless of age (hazard ratio, 0.59 [≥ 65 years] and 0.45 [≥ 70 years]). Adverse events (AEs) of special interest (all grades) that occurred more frequently with EVE than with PBO included stomatitis, infections, rash, pneumonitis, and hyperglycemia. Elderly EVE-treated patients had similar incidences of these AEs as did younger patients but had more on-treatment deaths. Adding EVE to EXE offers substantially improved PFS over EXE and was generally well tolerated in elderly patients with HR(+) advanced breast cancer. Careful monitoring and appropriate dose reductions or interruptions for AE management are recommended during treatment with EVE in this patient population. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Torupillitalu vägevad isad ja lapsed / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2008-01-01

    Rahvapillimängija ja pillimeistri Ants Tauli ja Tiiu Tauli Torupilli talust Valgamaal. Saunast, elamust, puhkemajast ja välikäimlast, mille on ehitanud Ants Taul. Hoovi ehib Erna Viitoli skulptuur torupillimängijast. Külalistemaja tugipalkidele nikerdas näod kunstiõpetaja Valev Elerand. Anu ja Triinu Taul isa Ants Taulist, vanaisa Johannes Taulist, oma lapsepõlvest. 9 värv. vaadet

  18. Pidulik lauakate laseb toidul särada / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2008-01-01

    Tallinna Kaubamaja kodukaupade ja tekstiilide peaostujuht Ulve Gailan, Tartu sisustussalongi Kodudisain juhataja Herle Mangus, Lea Niinepuu Lifestyle OÜ-st ja kaupluse Kiika Kööki müüja-konsultant Merilin Taul suvise peolaua katmisest, trendidest. Disainer Jaanus Kanna soovitusi suvise laudlina valikuks

  19. Eesti jäämurdekontseptsioon / Carol Kirss, Tarmo Kõuts

    Index Scriptorium Estoniae

    Kirss, Carol

    2005-01-01

    Autorite arvates on Eestis olemas risk, et sadamad jäävad külmadel talvedel piisava jäämurdevõimsuse juures blokeerituks. Võimalikest jäämurdekontseptsioonidest Eestis. Diagrammid: Kaubavedu Eesti sadamate kaudu; Eesti sadamate laevakülastused. Tabelid: Talvesadmate osatähtsus; Jäämurdjate optimaalse arvu selgitamine; Soome ja Liivi lahe erinevate jäämurdesüsteemide versioonide maksumus

  20. Ühe suguvõsa kunstnikud Rakvere muuseumis / Odette Kirss

    Index Scriptorium Estoniae

    Kirss, Odette

    1998-01-01

    Rakvere muuseumis toimunud Rakvere lähistelt pärit Mölderite-Vommide suguvõsa 13 kunstniku 1932-1998 a. tööde näitusest; lühidalt suguvõsast ja näitusel esindatud kunstnikest: Voldemar Mölder, Helene Mölder, Benita Vomm, August Vomm, Merike Rimm, Ingrid Järve, Indrek Järve, Silja Mölder, Helga-Maiken Hovi, Ants-Erik Vomm, Mai-Reet Järve, Jaak Järve, Toivo Peter Maricq

  1. Abutting Absence : Love Letters from Two Eras / Tiina Kirss

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2008-01-01

    Irene Lääne ja Toomas Hiio koostatud raamatust "Ühtekuuluvuse teel : Johan Laidoneri kirjad abikaasale" (Tallinn : Varrak, 2008) ja Käbi Laretei raamatust "Kuhu kadus kõik see armastus?" (Tallinn : SE & JS, 2008)

  2. Endogenous Retrovirus 3 – History, Physiology, and Pathology

    Science.gov (United States)

    Bustamante Rivera, Yomara Y.; Brütting, Christine; Schmidt, Caroline; Volkmer, Ines; Staege, Martin S.

    2018-01-01

    Endogenous viral elements (EVE) seem to be present in all eukaryotic genomes. The composition of EVE varies between different species. The endogenous retrovirus 3 (ERV3) is one of these elements that is present only in humans and other Catarrhini. Conservation of ERV3 in most of the investigated Catarrhini and the expression pattern in normal tissues suggest a putative physiological role of ERV3. On the other hand, ERV3 has been implicated in the pathogenesis of auto-immunity and cancer. In the present review we summarize knowledge about this interesting EVE. We propose the model that expression of ERV3 (and probably other EVE loci) under pathological conditions might be part of a metazoan SOS response. PMID:29379485

  3. Extended analysis of the Trojan-horse attack in quantum key distribution

    Science.gov (United States)

    Vinay, Scott E.; Kok, Pieter

    2018-04-01

    The discrete-variable quantum key distribution protocols based on the 1984 protocol of Bennett and Brassard (BB84) are known to be secure against an eavesdropper, Eve, intercepting the flying qubits and performing any quantum operation on them. However, these protocols may still be vulnerable to side-channel attacks. We investigate the Trojan-horse side-channel attack where Eve sends her own state into Alice's apparatus and measures the reflected state to estimate the key. We prove that the separable coherent state is optimal for Eve among the class of multimode Gaussian attack states, even in the presence of thermal noise. We then provide a bound on the secret key rate in the case where Eve may use any separable state.

  4. Endogenous Retrovirus 3 – History, Physiology, and Pathology

    Directory of Open Access Journals (Sweden)

    Yomara Y. Bustamante Rivera

    2018-01-01

    Full Text Available Endogenous viral elements (EVE seem to be present in all eukaryotic genomes. The composition of EVE varies between different species. The endogenous retrovirus 3 (ERV3 is one of these elements that is present only in humans and other Catarrhini. Conservation of ERV3 in most of the investigated Catarrhini and the expression pattern in normal tissues suggest a putative physiological role of ERV3. On the other hand, ERV3 has been implicated in the pathogenesis of auto-immunity and cancer. In the present review we summarize knowledge about this interesting EVE. We propose the model that expression of ERV3 (and probably other EVE loci under pathological conditions might be part of a metazoan SOS response.

  5. Estimation of radiation dose for adult and pediatric patients during X-ray examinations in Khartoum State

    International Nuclear Information System (INIS)

    Altahir, Ataalmanan Yosif Ataalmanan

    2018-01-01

    The aim of this study to evaluate the patient doses in X-ray examinations for skull and in three main hospitals in Khartoum State. The examination parameters took from 125 radiographs for both male and female were the females was 58 and the male 67 patients undergoing skull (AP), were the age of pediatric patients 1-18 years and adults 19-79 years. The result shows that the calculation of ESAK for according to gender for male skull 0.206 mGy, and ESAK according to gender for male skull 0.0719 mGy, for female skull 0.0942 mGy, for male chest 0.082 mGy and female for female chest 0.098 mGy. The calculation of ESAK according to patients age, adults and pediatric, the ESAK estimation for adults 0.122 mGy for skull, 0.1306 mGy for chest, and for pediatric 0.0432 mGy for skull, 0.055 mGy for chest. This data will be useful for the formulation of national reference levels as recommended by the International Atomic Energy Agency (IAEA). (Author)

  6. Prediction of response to antiretroviral therapy by human experts and by the EuResist data-driven expert system (the EVE study).

    Science.gov (United States)

    Zazzi, M; Kaiser, R; Sönnerborg, A; Struck, D; Altmann, A; Prosperi, M; Rosen-Zvi, M; Petroczi, A; Peres, Y; Schülter, E; Boucher, C A; Brun-Vezinet, F; Harrigan, P R; Morris, L; Obermeier, M; Perno, C-F; Phanuphak, P; Pillay, D; Shafer, R W; Vandamme, A-M; van Laethem, K; Wensing, A M J; Lengauer, T; Incardona, F

    2011-04-01

    The EuResist expert system is a novel data-driven online system for computing the probability of 8-week success for any given pair of HIV-1 genotype and combination antiretroviral therapy regimen plus optional patient information. The objective of this study was to compare the EuResist system vs. human experts (EVE) for the ability to predict response to treatment. The EuResist system was compared with 10 HIV-1 drug resistance experts for the ability to predict 8-week response to 25 treatment cases derived from the EuResist database validation data set. All current and past patient data were made available to simulate clinical practice. The experts were asked to provide a qualitative and quantitative estimate of the probability of treatment success. There were 15 treatment successes and 10 treatment failures. In the classification task, the number of mislabelled cases was six for EuResist and 6-13 for the human experts [mean±standard deviation (SD) 9.1±1.9]. The accuracy of EuResist was higher than the average for the experts (0.76 vs. 0.64, respectively). The quantitative estimates computed by EuResist were significantly correlated (Pearson r=0.695, Pexperts. However, the agreement among experts was only moderate (for the classification task, inter-rater κ=0.355; for the quantitative estimation, mean±SD coefficient of variation=55.9±22.4%). With this limited data set, the EuResist engine performed comparably to or better than human experts. The system warrants further investigation as a treatment-decision support tool in clinical practice. © 2010 British HIV Association.

  7. Everolimus plus exemestane as first-line therapy in HR⁺, HER2⁻ advanced breast cancer in BOLERO-2.

    Science.gov (United States)

    Beck, J Thaddeus; Hortobagyi, Gabriel N; Campone, Mario; Lebrun, Fabienne; Deleu, Ines; Rugo, Hope S; Pistilli, Barbara; Masuda, Norikazu; Hart, Lowell; Melichar, Bohuslav; Dakhil, Shaker; Geberth, Matthias; Nunzi, Martina; Heng, Daniel Y C; Brechenmacher, Thomas; El-Hashimy, Mona; Douma, Shyanne; Ringeisen, Francois; Piccart, Martine

    2014-02-01

    The present exploratory analysis examined the efficacy, safety, and quality-of-life effects of everolimus (EVE) + exemestane (EXE) in the subgroup of patients in BOLERO-2 whose last treatment before study entry was in the (neo)adjuvant setting. In BOLERO-2, patients with hormone-receptor-positive (HR(+)), human epidermal growth factor receptor-2-negative (HER2(-)) advanced breast cancer recurring/progressing after a nonsteroidal aromatase inhibitor (NSAI) were randomly assigned (2:1) to receive EVE (10 mg/day) + EXE (25 mg/day) or placebo (PBO) + EXE. The primary endpoint was progression-free survival (PFS) by local assessment. Overall, 137 patients received first-line EVE + EXE (n = 100) or PBO + EXE (n = 37). Median PFS by local investigator assessment nearly tripled to 11.5 months with EVE + EXE from 4.1 months with PBO + EXE (hazard ratio = 0.39; 95 % CI 0.25-0.62), while maintaining quality of life. This was confirmed by central assessment (15.2 vs 4.2 months; hazard ratio = 0.32; 95 % CI 0.18-0.57). The marked PFS improvement in patients receiving EVE + EXE as first-line therapy for disease recurrence during or after (neo)adjuvant NSAI therapy supports the efficacy of this combination in the first-line setting. Furthermore, the results highlight the potential benefit of early introduction of EVE + EXE in the management of HR(+), HER2(-) advanced breast cancer in postmenopausal patients.

  8. Ultralow-dose CT of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction and model-based iterative reconstruction: 2D and 3D image quality.

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Gassner, Eva-Maria; Hoermann, Romed; Bale, Reto; Puelacher, Wolfgang

    2015-03-01

    OBJECTIVE. The purpose of this article is to evaluate 2D and 3D image quality of high-resolution ultralow-dose CT images of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard filtered backprojection (FBP). MATERIALS AND METHODS. A formalin-fixed human cadaver head was scanned using a clinical reference protocol at a CT dose index volume of 30.48 mGy and a series of five ultralow-dose protocols at 3.48, 2.19, 0.82, 0.44, and 0.22 mGy using FBP and ASIR at 50% (ASIR-50), ASIR at 100% (ASIR-100), and MBIR. Blinded 2D axial and 3D volume-rendered images were compared with each other by three readers using top-down scoring. Scores were analyzed per protocol or dose and reconstruction. All images were compared with the FBP reference at 30.48 mGy. A nonparametric Mann-Whitney U test was used. Statistical significance was set at p ASIR-100 at 3.48 mGy, ASIR-100 at 2.19 mGy, and MBIR at 0.82 mGy. MBIR at 2.19 and 3.48 mGy scored statistically significantly better than the FBP reference (p = 0.032 and 0.001, respectively). For 3D images, the FBP reference at 30.48 mGy did not statistically significantly differ from all reconstructions at 3.48 mGy; FBP and ASIR-100 at 2.19 mGy; FBP, ASIR-100, and MBIR at 0.82 mGy; MBIR at 0.44 mGy; and MBIR at 0.22 mGy. CONCLUSION. MBIR (2D and 3D) and ASIR-100 (2D) may significantly improve subjective image quality of ultralow-dose images and may allow more than 90% dose reductions.

  9. Effect of visceral metastases on the efficacy and safety of everolimus in postmenopausal women with advanced breast cancer: subgroup analysis from the BOLERO-2 study.

    Science.gov (United States)

    Campone, Mario; Bachelot, Thomas; Gnant, Michael; Deleu, Ines; Rugo, Hope S; Pistilli, Barbara; Noguchi, Shinzaburo; Shtivelband, Mikhail; Pritchard, Kathleen I; Provencher, Louise; Burris, Howard A; Hart, Lowell; Melichar, Bohuslav; Hortobagyi, Gabriel N; Arena, Francis; Baselga, José; Panneerselvam, Ashok; Héniquez, Aurelia; El-Hashimyt, Mona; Taran, Tetiana; Sahmoud, Tarek; Piccart, Martine

    2013-08-01

    Everolimus (EVE; an inhibitor of mammalian target of rapamycin [mTOR]) enhances treatment options for postmenopausal women with hormone-receptor-positive (HR(+)), human epidermal growth factor receptor-2-negative (HER2(-)) advanced breast cancer (ABC) who progress on a non-steroidal aromatase inhibitor (NSAI). This is especially true for patients with visceral disease, which is associated with poor prognosis. The BOLERO-2 (Breast cancer trial of OraLEveROlimus-2) trial showed that combination treatment with EVE and exemestane (EXE) versus placebo (PBO)+EXE prolonged progression-free survival (PFS) by both investigator (7.8 versus 3.2 months, respectively) and independent (11.0 versus 4.1 months, respectively) central assessment in postmenopausal women with HR(+), HER2(-) ABC recurring/progressing during/after NSAI therapy. The BOLERO-2 trial included a substantial proportion of patients with visceral metastases (56%). Prespecified exploratory subgroup analysis conducted to evaluate the efficacy and safety of EVE+EXE versus PBO+EXE in a prospectively defined subgroup of patients with visceral metastases. At a median follow-up of 18 months, EVE+EXE significantly prolonged median PFS compared with PBO+EXE both in patients with visceral metastases (N=406; 6.8 versus 2.8 months) and in those without visceral metastases (N=318; 9.9 versus 4.2 months). Improvements in PFS with EVE+EXE versus PBO+EXE were also observed in patients with visceral metastases regardless of Eastern Cooperative Oncology Group performance status (ECOG PS). Patients with visceral metastases and ECOG PS 0 had a median PFS of 6.8 months with EVE+EXE versus 2.8 months with PBO+EXE. Among patients with visceral metastases and ECOG PS ≥1, EVE+EXE treatment more than tripled median PFS compared with PBO+EXE (6.8 versus 1.5 months). Adding EVE to EXE markedly extended PFS by ≥4 months among patients with HR(+) HER2(-) ABC regardless of the presence of visceral metastases. Copyright © 2013 The

  10. Optimizing the balance between radiation dose and image quality in pediatric head CT: findings before and after intensive radiologic staff training.

    Science.gov (United States)

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Puglioli, Michele; Caramella, Davide; Bartolozzi, Carlo

    2014-06-01

    The purpose of this study was to assess the radiation dose and image quality of pediatric head CT examinations before and after radiologic staff training. Outpatients 1 month to 14 years old underwent 215 unenhanced head CT examinations before and after intensive training of staff radiologists and technologists in optimization of CT technique. Patients were divided into three age groups (0-4, 5-9, and 10-14 years), and CT dose index, dose-length product, tube voltage, and tube current-rotation time product values before and after training were retrieved from the hospital PACS. Gray matter conspicuity and contrast-to-noise ratio before and after training were calculated, and subjective image quality in terms of artifacts, gray-white matter differentiation, noise, visualization of posterior fossa structures, and need for repeat CT examination was visually evaluated by three neuroradiologists. The median CT dose index and dose-length product values were significantly lower after than before training in all age groups (27 mGy and 338 mGy ∙ cm vs 107 mGy and 1444 mGy ∙ cm in the 0- to 4-year-old group, 41 mGy and 483 mGy ∙ cm vs 68 mGy and 976 mGy ∙ cm in the 5- to 9-year-old group, and 51 mGy and 679 mGy ∙ cm vs 107 mGy and 1480 mGy ∙ cm in the 10- to 14-year-old group; p training were significantly lower than the levels before training (p staff training can be effective in reducing radiation dose while preserving diagnostic image quality in pediatric head CT examinations.

  11. Radiation absorbed doses in cephalography

    International Nuclear Information System (INIS)

    Eliasson, S.; Julin, P.; Richter, S.; Stenstroem, B.

    1984-01-01

    Radiation absorbed doses to different organs in the head and neck region in lateral (LAT) and postero-anterior (PA) cephalography were investigated. The doses were measured by thermoluminescence dosimeters (TLD) on a tissue equivalent phantom head. Lanthanide screens in speed group 4 were used at 90 and 85 k Vp. A near-focus aluminium dodger was used and the radiation beam was collimated strictly to the face. The maximum entrance dose from LAT was 0.25 mGy and 0.42 mGy from a PA exposure. The doses to the salivary glands ranged between 0.2 and 0.02 mGy at LAT and between 0.15 and 0.04 mGy at PA exposures. The average thyroid gland dose without any shielding was 0.11 mGy (LAT) and 0.06 mGy (PA). When a dodger was used the dose was reduced to 0.07 mGy (LAT). If the thyroid gland was sheilded off, the dose was further reduced to 0.01 mGy and if the thyroid region was collimated out of the primary radiation field the dose was reduced to only 0.005 mGy. (authors)

  12. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup [Radiation Safety Division National Institute of Food and Drug Safety Evaluation, Seoul (Korea, Republic of)

    2009-12-15

    entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  13. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup

    2009-01-01

    entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  14. Parvovirus-derived endogenous viral elements in two South American rodent genomes.

    Science.gov (United States)

    Arriagada, Gloria; Gifford, Robert J

    2014-10-01

    We describe endogenous viral elements (EVEs) derived from parvoviruses (family Parvoviridae) in the genomes of the long-tailed chinchilla (Chinchilla lanigera) and the degu (Octodon degus). The novel EVEs include dependovirus-related elements and representatives of a clearly distinct parvovirus lineage that also has endogenous representatives in marsupial genomes. In the degu, one dependovirus-derived EVE was found to carry an intact reading frame and was differentially expressed in vivo, with increased expression in the liver. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  15. Victims of stalking in India: A study of girl college students in Tirunelveli City

    OpenAIRE

    Jaishankar Karuppannan; Kosalai Puthisigamani

    2007-01-01

    The word 'stalking' was not commonly known in India, until Priyadharshini Mattoo's case (1996) hit the headlines. Eve teasing, a colloquial word for gender harassment is popularly known and Tamil Nadu Prohibition of Eve-Teasing Act, 1998 on that was developed after the brutal killing of a girl named Sarika Shah in Chennai. Though, stalking is there in the past, it was not acknowledged with this terminology and it was always merged with Eve teasing. On the other hand, stalking is much graver t...

  16. Endovascular Embolization of Bronchial Artery Originating from the Upper Portion of Aortic Arch in Patients with Massive Hemoptysis

    International Nuclear Information System (INIS)

    Jiang, Sen; Sun, Xi-Wen; Yu, Dong; Jie, Bing

    2014-01-01

    PurposeOur experience with endovascular embolization (EVE) of the bronchial artery (BA) originating from the upper portion of the aortic arch (AA) in six patients is described.MethodsAltogether, 818 patients with hemoptysis underwent multidetector row computed tomography angiography (MDCTA) before EVE or AA angiography during EVE. Aberrant BAs originating from the upper portion of the AA were the source of massive hemoptysis in six patients (0.73 %). MDCT angiograms and/or Digital subtraction angiograms were retrospectively reviewed. Selective catheterization and embolization were performed.ResultsThe ostia of the BAs were located on the superior surface of the AA between the brachiocephalic trunk and left common carotid artery in three patients, the junction of the aorta and medial surface of the left subclavian artery in two, and the posterior wall of the upper portion of the AA in one. The six BAs comprised two common trunks, three single right sides, and one single left side. The targeted vessels were successfully catheterized and embolized by a coaxial microcatheter system using polyvinyl alcohol particles. Other pathologic BAs and nonbronchial systemic arteries also were embolized. Bleeding was immediately controlled in all patients with no recurrence of hemoptysis. No procedure-related complications occurred.ConclusionsApplication of EVE of anomalous origin of BAs in patients with hemoptysis is important, as demonstrated in the six reported patients. MDCTA before EVE or AA angiography during EVE is critical to avoid missing a rare aberrant BA originating from the upper portion of the AA

  17. Evaluation of radiation dose during the percutaneous angioplasty for arteriovenous shunt assembling

    Science.gov (United States)

    Ting, Chien-Yi; Wu, Wen-Shiann; Tang, Kuo-Ting; Wang, Hsin-Ell; Lin, Chun-Chih

    2017-11-01

    Percutaneous angioplasty (PTA) for dysfunctional hemodialysis is usually performed by radiologists, but not cardiologists, in Taiwan, so that the radiation dose in patients and physicians are usually unknown and related studies are rare. In this study, we are pioneering an investigation into the radiation dose in percutaneous angioplasty for arteriovenous shunt assembling and the effect of RADPAD device, a lead-free surgical drape containing Bi and Ba, on the decrease of a radiation dose in the non-targeted organs of the patient and also the operator. The radiation dose in a typical digital subtraction angiography (DSA) by the PTA protocol under a fixed field of view (FOV), was measured with optically simulated luminescent dosimeters arranged in a PIXY RS-102 anthropomorphic phantom. The results indicate that there is a significant dose reduction at the hands (0.022±0.002 mGy before treatment vs. 0.014±0.001 mGy after treatment; P=0.021), but not at the lens (0.027±0.003 mGy before treatment vs. 0.018±0.001 mGy after treatment; P=0.058), and the gonads (0.026±0.003 mGy before treatment vs. 0.020±0.001 mGy after treatment; P=0.058), of the cardiologist/operator after treatment with the RADPAD drape. At the patient's abdomen, the dose significantly decreased from 1.597±0.104 mGy to 0.031±0.002 mGy (PRADPAD shield. For the chest, lens and thyroid in the patient, the doses were respectively 0.154±0.100 mGy (compared to 0.049±0.001 mGy after treated with the RADPAD drape; P=0.0002), 0.066±0.001 mGy (compared to 0.021±0.001 mGy after the RADPAD treatment; P=0.009), and 0.208±0.002 mGy (compared to 0.042±0.003 mGy after shielded with the RADPAD drape; PRADPAD drape significantly reduced radiation exposure to the patient during the PTA for the arteriovenous shunt assembling, which is suggested should be applied to the current cardiac catheterization.

  18. Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography

    International Nuclear Information System (INIS)

    Kirchhoff, S.; Herzog, P.; Johnson, T.; Boehm, H.; Nikolaou, K.; Reiser, M.F.; Becker, C.H.

    2010-01-01

    Objective: The radiation exposure of a dual-source-64-channel multi-detector-computed-tomography-scanner (Somatom-Defintion, Siemens, Germany) was assessed in a phantom-study performing coronary-CT-angiography (CTCA) in comparison to patients' data randomly selected from routine scanning. Methods: 240 CT-acquisitions of a computed tomography dose index (CTDI)-phantom (PTW, Freiburg, Germany) were performed using a synthetically generated Electrocardiography (ECG)-signal with variable heart rates (30-180 beats per minute (bpm)). 120 measurements were acquired using continuous tube-output; 120 measurements were performed using ECG-synchronized tube-modulation. The pulsing window was set at minimum duration at 65% of the cardiac cycle between 30 and 75 bpm. From 90-180 bpm the pulsing window was set at 30-70% of the cardiac cycle. Automated pitch adaptation was always used. A comparison between phantom CTDI and two patient groups' CTDI corresponding to the two pulsing groups was performed. Results: Without ECG-tube-modulation CDTI-values were affected by heart-rate-changes resulting in 85.7 mGray (mGy) at 30 and 45 bpm, 65.5 mGy/60 bpm, 54.7 mGy/75 bpm, 46.5 mGy/90 bpm, 34.2 mGy/120 bpm, 27.0 mGy/150 bpm and 22.1 mGy/180 bpm equal to effective doses between 14.5 mSievert (mSv) at 30/45 bpm and 3.6 mSv at 180 bpm. Using ECG-tube-modulation these CTDI-values resulted: 32.6 mGy/30 bpm, 36.6 mGy/45 bpm, 31.4 mGy/60 bpm, 26.8 mGy/75 bpm, 23.7 mGy/90 bpm, 19.4 mGy/120 bpm, 17.2 mGy/150 bpm and 15.6 mGy/180 bpm equal to effective doses between 5.5 mSv at 30 bpm and 2.6 mSv at 180 bpm. Significant CTDI-differences were found between patients with lower/moderate and higher heart rates in comparison to the phantom CTDI-results. Conclusions: Dual source CTCA is particularly dose efficient at high heart rates when automated pitch adaptation, especially in combination with ECG-based tube-modulation is used. However in clinical routine scanning for patients with higher heart rates

  19. Measurements of radiation dose to patients undergoing some common radiographic x-ray examinations in Wad Madani hospitals

    International Nuclear Information System (INIS)

    Mohammedzein, T. S.

    2009-12-01

    The aim of this study was to assess patient doses in most common radiographic x-ray examinations in Wad Madani hospitals of Al Gazera State. The examination parameters of 388 radiographs were used to calculate the Entrance Surface Air Kerma (ESAK) of patients undergoing skull (AP and LAT), chest (PA), pelvis (AP), abdomen (AP) and lumbar spin (AP and LAT) in six major hospitals. Hospital mean ESAKs estimated range from 0.0729-0.69 mGy for chest PA, 0.338-6.64 mGy for skull PA, 0.195-5.8 mGy for skull LAT, 0.595-3.42 mGy for pelvis AP, 0.772-6.31 mGy for lumbar spine AP, 2.1-15.2 mGy for lumbar spine LAT and 0.742-5.79 mGy for abdomen. This data will be useful for the formulation of national reference levels as recommended by International Atomic Energy Agency (IAEA). (Author)

  20. Official holidays in 2011

    CERN Multimedia

    HR Department

    2011-01-01

    (Application of Article R II 4.39 of the Staff Regulations) Official holidays in 2011 (in addition to the special leave during the annual closure): Saturday 1 January\t(New Year) Friday 22 April\t(Good Friday) Monday 25 April\t(Easter Monday) Sunday 1 May Thursday 2 June\t(Ascension day) Friday 3 June\t(compensation granted for 1 May) Monday 13 June\t(Whit Monday) Thursday 8 September\t(“Jeûne genevois”)  Thursday 22 December\t(compensation granted for 24 December, Christmas Eve) Friday 23 December\t(compensation granted for 25 December, Christmas) Saturday 24 December\t(Christmas Eve) Sunday 25 December\t(Christmas) Thursday 29 December\t(compensation granted for 31 December, New Year’s Eve) Friday 30 December\t(compensation granted for 1 January 2012, New Year) Saturday 31 December\t(New Year’s Eve) Tel. 73903

  1. Effect of external volume expansion on the survival of fat grafts

    Directory of Open Access Journals (Sweden)

    Raghuveer Reddy

    2016-01-01

    Full Text Available Introduction: External volume expansion (EVE is one method, which has been utilised for increasing the survival of adipose tissue grafts. EVE releases positive pressure from the graft and also induces intense levels of edema that decreases diffusion of metabolites essential for graft survival initially. The ideal timing of external volume expansion in relation to the injection of the fat to facilitate survival is not yet clear. Aims and Objectives: This study was undertaken to evaluate and compare the efficacy of external volume expansion applied at variable time points in relation to the injection of the fat. Materials and Methods: Athymic mouse was the animal model and human lipo-aspirate mixed with PRP was used as graft. An indigenous dome shaped silicone device was fabricated to deliver a negative pressure of -30 mm of Hg. The EVE was applied at variable time intervals. At the end of 4 weeks visual, histological and radiological features of the injected fat were compared. The adipose tissue was stained with human vimentin to ascertain the origin of the retained fat. Results: All the grafts, which had EVE, had significantly better volume retention and vascularity. The groups which underwent a delayed EVE or prior expansion followed by concomitant graft injection and expansion showed the most optimal vascularity and graft retention. Conclusions: A delayed EVE or prior expansion followed by concomitant graft injection and expansion may be the most ideal combinations to optimize graft take. However, on account of the relatively small sample size, there was a limitation in drawing statistically significant conclusions for certain variables.

  2. Niche partitioning of marine group I Crenarchaeota in the euphotic and upper mesopelagic zones of the East China Sea.

    Science.gov (United States)

    Hu, Anyi; Jiao, Nianzhi; Zhang, Rui; Yang, Zao

    2011-11-01

    Marine group I Crenarchaeota (MGI) represents a ubiquitous and numerically predominant microbial population in marine environments. An understanding of the spatial dynamics of MGI and its controlling mechanisms is essential for an understanding of the role of MGI in energy and element cycling in the ocean. In the present study, we investigated the diversity and abundance of MGI in the East China Sea (ECS) by analysis of crenarchaeal 16S rRNA gene, the ammonia monooxygenase gene amoA, and the biotin carboxylase gene accA. Quantitative PCR analyses revealed that these genes were higher in abundance in the mesopelagic than in the euphotic zone. In addition, the crenarchaeal amoA gene was positively correlated with the copy number of the MGI 16S rRNA gene, suggesting that most of the MGI in the ECS are nitrifiers. Furthermore, the ratios of crenarchaeal accA to amoA or to MGI 16S rRNA genes increased from the euphotic to the mesopelagic zone, suggesting that the role of MGI in carbon cycling may change from the epipelagic to the mesopelagic zones. Denaturing gradient gel electrophoretic profiling of the 16S rRNA genes revealed depth partitioning in MGI community structures. Clone libraries of the crenarchaeal amoA and accA genes showed both "shallow" and "deep" groups, and their relative abundances varied in the water column. Ecotype simulation analysis revealed that MGI in the upper ocean could diverge into special ecotypes associated with depth to adapt to the light gradient across the water column. Overall, our results showed niche partitioning of the MGI population and suggested a shift in their ecological functions between the euphotic and mesopelagic zones of the ECS.

  3. Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography.

    Science.gov (United States)

    James, Judy R; Pavlicek, William; Hanson, James A; Boltz, Thomas F; Patel, Bhavika K

    2017-02-01

    We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

  4. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  5. Financialised capitalism Soviet style? Varieties of state capture and crisis

    NARCIS (Netherlands)

    Visser, A.; Kalb, D.P.

    2010-01-01

    Looking for new ways to interpret the failings of the neo-liberal economy, this article argues that financialised capitalism at the eve of the 2008 financial crisis showed striking analogies with the characteristic combination of oligopoly and informality of the Soviet economy at the eve of its

  6. Gayatri Chakravorty Spivak : feminism ja postkolonialismi looklev rada / Tiina Kirss

    Index Scriptorium Estoniae

    Kirss, Tiina, 1957-

    2003-01-01

    Ühest tunnustatuimast postkolonialismi teoreetikust - hindulannast Gayatri Chakravorty Spivakist, tema kirjeldatud India naise seisundist koloniaalses ja postkoloniaalses ühiskonnas, mõistest "subaltern"

  7. Introducing the Internet-based TOEFL test / Epp Kirss, Mare Roes

    Index Scriptorium Estoniae

    Kirss, Epp

    2013-01-01

    Internetipõhisest rahvusvaheliselt tunnustatud standardiseeritud inglise keele testist, mida nõutakse USA ülikoolidesse kandideerivatelt rahvusvahelistelt üliõpilastelt ning selle õpetamise kogemusest

  8. Mölderite-Vommide suguvõsa kunstinäitus / Odette Kirss

    Index Scriptorium Estoniae

    Kirss, Odette

    1998-01-01

    Septembris Rakvere muuseumis Rakvere sepa Hans Mölderi ja abikaasa Alide-Therese (Wunderlich) järglaste, pereliikmete ja lähemate sugulaste tööd aastaist 1932-1988. Näitus on pühendatud Benita Vommi 90. sünnipäevale.

  9. Applications of the Galton-Watson process to human DNA evolution and demography

    CERN Document Server

    Neves, A G M

    2005-01-01

    We show that the problem of existence of a mitochondrial Eve can be understood as an application of the Galton--Watson process and presents interesting analogies with critical phenomena in Statistical Mechanics. In the approximation of small survival probability, and assuming limited progeny, we are able to find for a genealogic tree the maximum and minimum survival probabilities over all probability distributions for the number of children per woman constrained to a given mean. As a consequence, we can relate existence of a mitochondrial Eve to quantitative demographic data of early mankind. In particular, we show that a mitochondrial Eve may exist even in an exponentially growing population, provided that the mean number of children per woman $\\overline N$ is constrained to a small range depending on the probability $p$ that a child is a female. Assuming that the value $p \\approx 0.488$ valid nowadays has remained fixed for thousands of generations, the range where a mitochondrial Eve occurs with sizeable p...

  10. Measurement and estimation of maximum skin dose to the patient for different interventional procedures

    International Nuclear Information System (INIS)

    Cheng Yuxi; Liu Lantao; Wei Kedao; Yu Peng; Yan Shulin; Li Tianchang

    2005-01-01

    Objective: To determine the dose distribution and maximum skin dose to the patient for four interventional procedures: coronary angiography (CA), hepatic angiography (HA), radiofrequency ablation (RF) and cerebral angiography (CAG), and to estimate the definitive effect of radiation on skin. Methods: Skin dose was measured using LiF: Mg, Cu, P TLD chips. A total of 9 measuring points were chosen on the back of the patient with two TLDs placed at each point, for CA, HA and RF interventional procedures, whereas two TLDs were placed on one point each at the postero-anterior (PA) and lateral side (LAT) respectively, during the CAG procedure. Results: The results revealed that the maximum skin dose to the patient was 1683.91 mGy for the HA procedure with a mean value of 607.29 mGy. The maximum skin dose at the PA point was 959.3 mGy for the CAG with a mean value of 418.79 mGy; While the maximum and the mean doses at the LAT point were 704 mGy and 191.52 mGy, respectively. For the RF procedure the maximum dose was 853.82 mGy and the mean was 219.67 mGy. For the CA procedure the maximum dose was 456.1 mGy and the mean was 227.63 mGy. Conclusion: All the measured dose values in this study are estimated ones which could not provide the accurate maximum value because it is difficult to measure using a great deal of TLDs. On the other hand, the small area of skin exposed to high dose could be missed as the distribution of the dose is successive. (authors)

  11. Estimation of entrance dose during selected fluoroscopic examinations in some hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Mohammed, Heba Abdalkareem Osman

    2016-01-01

    A diagnostic fluoroscopy is a modality that involves visualizing the anatomy using radiation in real time. Therefore, patients doses have a potential for being great, increasing the chance of the radiation induced carcinogenesis. The objective of this study was to determine the mean entrance surface dose (ESD) from selected fluoroscopic examinations namely, hysterosalpingography (HSG) and ascendingurethogram (ASU) in three hospitals in Khartoum State. A total of 87 and 110 patents for HSG and ASU respectively were examined. The data were collected over four months. The mean ESD for patients who underwent HSG were 16.2 mGy, 20.6 mGy and 25.9 mGY respectively, while the ESD for patient who underwent ascendingurethrogram for AP view were 3.5mGy, 2.9mGy and 11.9mGy and for OB view 15.9 mGy, 18.3 mGy and 25.4 mGy. Patient doses were calculated using mathematical equation and the results were compared with the ESDs calculated using mathematical equation and the results were found to be comparable with the ESDs reported in previous studies and within the guidance level established by the ICRP. Fluoroscopy time, operator skills, x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported in the measured ESDs. The study demonstrated the need for standardization of techniques throughout the hospitals and suggested that there ia a need to optimize the procedures.(Author)

  12. Preliminary evaluation of exposures of computerized tomography patients in Latin America: IAEA project RLA/9/67

    International Nuclear Information System (INIS)

    Kodlulovich, S.; Silveira, V.; Khoury, H.J.

    2013-01-01

    The aim of this study was to obtain preliminary values of reference levels in CT . Were sent to each country forms with information of radiological protection and routine CT protocols. The CT dose index and absorbed dose to organs was estimated from the technical data for each equipment . The results showed that the total number of examinations performed 92 % are adult patients and 8 % are children. The most frequent examination of the skull was adult (40 % ) and abdomen for children (42 % ) . About the service , 67 % of the equipment are multicut and 76 % have specific protocols for pediatric patients. The CTDI vol values for head exams of adults vary between 2 and 352 mGy for pediatric patients under 1 year 1-191 mGy under 7 years old 5-335 mGy. For chest values ranged from 3 to 26 mGy for adults, between 1 and 89 mGy for children under 1 year and between 3-114 mGy for children between 1 and 7 years. Exams of the abdomen/pelvis of adults the range was 3-47 mGy , between 4-90 mGy for children under 1 year and between 2-31 mGy for children between 1 and 7 years. This study showed that although there are pediatric protocols, there is a wide variation in values of CTDl vol indicating a high potential for dose reduction. This result requires immediate action for optimization and implementation of diagnostic reference values in Latin America

  13. Portable electronic vision enhancement systems in comparison with optical magnifiers for near vision activities: an economic evaluation alongside a randomized crossover trial.

    Science.gov (United States)

    Bray, Nathan; Brand, Andrew; Taylor, John; Hoare, Zoe; Dickinson, Christine; Edwards, Rhiannon T

    2017-08-01

    To determine the incremental cost-effectiveness of portable electronic vision enhancement system (p-EVES) devices compared with optical low vision aids (LVAs), for improving near vision visual function, quality of life and well-being of people with a visual impairment. An AB/BA randomized crossover trial design was used. Eighty-two participants completed the study. Participants were current users of optical LVAs who had not tried a p-EVES device before and had a stable visual impairment. The trial intervention was the addition of a p-EVES device to the participant's existing optical LVA(s) for 2 months, and the control intervention was optical LVA use only, for 2 months. Cost-effectiveness and cost-utility analyses were conducted from a societal perspective. The mean cost of the p-EVES intervention was £448. Carer costs were £30 (4.46 hr) less for the p-EVES intervention compared with the LVA only control. The mean difference in total costs was £417. Bootstrapping gave an incremental cost-effectiveness ratio (ICER) of £736 (95% CI £481 to £1525) for a 7% improvement in near vision visual function. Cost per quality-adjusted life year (QALY) ranged from £56 991 (lower 95% CI = £19 801) to £66 490 (lower 95% CI = £23 055). Sensitivity analysis varying the commercial price of the p-EVES device reduced ICERs by up to 75%, with cost per QALYs falling below £30 000. Portable electronic vision enhancement system (p-EVES) devices are likely to be a cost-effective use of healthcare resources for improving near vision visual function, but this does not translate into cost-effective improvements in quality of life, capability or well-being. © 2016 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation and European Association for Vision & Eye Research.

  14. The Third International Intercomparison on EPR Tooth Dosimetry: Part 2, final analysis

    International Nuclear Information System (INIS)

    Wieser, A.; Debuyst, R.; Fattibene, P.; Meghzifene, A.; Onori, S.; Bayankin, S. N.; Brik, A.; Bugay, A.; Chumak, V.; Ciesielski, B.; Hoshi, M.; Imata, H.; Ivannikov, A.; Ivanov, D.; Junczewska, M.; Miyazawa, C.; Penkowski, M.; Pivovarov, S.; Romanyukha, A.; Romanyukha, L.; Schauer, D.; Scherbina, O.; Schultka, K.; Sholom, S.; Skvortsov, V.; Stepanenko, V.; Thomas, J. A.; Tielewuhan, E.; Toyoda, S.; Trompier, F.

    2006-01-01

    The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation. (authors)

  15. IN VITRO CULTURE OF HOLOPARASITE Rafflesia arnoldii R. Brown

    Directory of Open Access Journals (Sweden)

    Lazarus Agus Sukamto

    2010-07-01

    Full Text Available Potongan kuncup bunga digunakan sebagai eksplan yang ditumbuhkan pada media dasar Murashige and Skoog (MS dengan tambahan 0; 0.1; 0.5; 1 and 5 mg/I 2,4-D atau Picloram dan 2 g/I Phytagel. Eksplan tumbuh menjadi kalus pada media yang ditambahkan 0,1 dan 1 mg/I 2,4-D atau 0,5 dan 1 mg/I Picloram. Kultur kalus tersebut dipelihara pada media MS + 1 mg/I 2,4-D. Kemudian kalus ditumbuhkan pada medium dengan penambahan 1, 3, 5 dan 10 mg/I 2,4-D atau Picloram. Setelah dua bulan 66,67-100% kultur membentuk kalus. Semua kalus berstruktur kompak. Beberapa kalus yang diperlakuan dengan 5-10 mg/I 2,4-D menumbuhkan benang-benang putih pada permukaannya. Perlakuan Picloram menghasilkan kalus yang lebih banyak, tetapi 2,4-D menghasilkan kualitas kalus yang lebih baik. Kalus R. arnoldii tidak membentuk somatik embrio dengan penambahan 0,1 mg/I Zeatin dalam media kultur. Ini adalah laporan yang pertama kali tentang pembentukan kalus dari kultur R. arnoldii secara in vitro.

  16. The Sovereign Citizen Movement: The Shifting Ideological Winds

    Science.gov (United States)

    2016-03-01

    theology asserts that Eve had sex with the devil and Adam on the same day.52 In this theology, the offspring of Adam and Eve produced an Aryan...diminished. White kids flocked to purchase Michael Jordan jerseys and America’s pastime was well integrated. Black singers, artists, writers, and

  17. HOTEL INFORMATION

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Park Plaza Beijing Wangfujing Christmas Eve Celebration at Bloo restaurant on December 24,17:30 p.m.-10:30 p.m.Christmas Eve Dinner Buffet:Indulge in a lavish seafood buffet and international cuisine stations. Groove to live jazz and pop music as you try to win attractive lucky

  18. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  19. Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

    International Nuclear Information System (INIS)

    Yamada, M.; Komiya, N.; Kawaguchi, A.; Suzuki, M.; Suzuki, Shoichi; Asada, Yasuki

    2008-01-01

    The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE; MS90Tj) system to an FPD (Shimadzu; SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examination of the extent to which exposure could be reduced. Two TV systems were used. We used an analyzer to measure output waveform, tube voltage, and half-value layer (HVL), and an ionization chamber dosimeter to carry out dose-in-air measurements. Body thickness, number of image acquisitions, and fluoroscopy time are required for the calculation of entrance skin dose (ESD). We therefore measured body thicknesses in 1000 upper gastrointestinal tract (UGI) and barium enemas and obtained average body thicknesses for males and females by age group. Values used for number of image acquisitions and fluoroscopy times were the averages in our institution over a two-year period. When an I.I. system was used, the average ESD during UGI examination were 126.8 mGy fluoroscopy dose and 11.62 mGy imaging dose, for an average total dose of 138.42 mGy per examination. ESD during barium enema averaged 201.73 mGy fluoroscopy dose and 45.2 mGy imaging dose, for an average total dose of 246.92 mGy per examination. When an FPD system was used, the average ESD during UGI examination were 58.71 mGy fluoroscopy dose and 5.72 mGy imaging dose, for an average total dose of 64.43 mGy per examination. ESD during barium enema averaged 112.21 mGy fluoroscopy dose and 24.55 mGy imaging dose, for an average total dose of 136.76 mGy per examination. The use of an FPD system reduced both fluoroscopy dose and imaging dose by 50%. The number of TV systems equipped with FPD in Japan has increased from around 1300 in 2006 to around 1700 in 2007. The use of FPD systems can be expected to increase in future. This

  20. Quantum authentication based on the randomness of measurement bases in BB84

    International Nuclear Information System (INIS)

    Dang Minh Dung; Bellot, P.; Alleaume, R.

    2005-01-01

    Full text: The establishment of a secret key between two legitimate end points of a communication link, let us name them Alice and Bob, using Quantum key distribution (QKD) is unconditionally secure thanks to Quantum Physics laws.However, the various QKD protocols do not intend to provide the authentication of the end points: Alice cannot be sure that she is communicating with Bob and reciprocally. Therefore, these protocols are subjects to various attacks. The most obvious attack is the man-in-the-middle attack in which an eavesdropper, let us name her Eve, stands in the middle of the communication link. Alice communicates with Eve meanwhile she thinks she communicate with Bob. And Bob communicates with Eve meanwhile he thinks he is communicating with Alice. Eve, acting as a relay, can read all the communications between Alice and Bob and retransmit them. To prevent this kind of attack, the solution is to authenticate the two end points of the communication link. One solution is that Alice and Bob share an authentication key prior to the communication. In order to improve the security, Alice and Bob must share a set of authentication one-time keys. One-time key means that the key has to be used only once because each time a key is used, the eavesdropper Eve can gain a few information on the key. Re-using the same key many times would finally reveal the key to Eve. However, Eve can simulate many times the authentication process with Alice. Each time Eve simulates the authentication process, one of the pre-positioned keys is depleted leading to the exhaustion of the set of pre-positioned keys. This type of attack is named Denial of Service attack. In this work, we propose to use the randomness of the measurement bases in BB84 to build an authentication scheme based on the existence of a prepositioned authentication key. This authentication scheme can be used with BB84 but also with any other Quantum Key Distribution protocols. It is protected against the Denial of

  1. Survey of image quality and patient dose in simple radiographic examinations: establishing guidance levels and comparison with international standards

    International Nuclear Information System (INIS)

    Manatrakul, N.; Bunsoong, T.; Krisanachinda, A.; Suwanpradit, P.; Rungruengthanakit, P.; Kanchart, S.; Chaiwong, Rajikorn; Tsapakig, V.A.

    2008-01-01

    Purpose: To investigate image quality and patient dose for commonly radiographic examinations in Thailand, to establish national reference or guidance levels (GL) and compare with international standards, as part of an International Atomic Energy Agency (IAEA) project on Radiation Protection of Patients and Medical Exposure Control (RAS/9/034 and RAS/9/047). Materials and Methods: Film reject rate analysis, image quality and patient dose assessment before and after Quality Control (QC) implementation were investigated in 8 X-ray machines in 4 hospitals. Air kerma (in mGy) at 1 meter focus-detector-distance for different kVp settings for each X-ray machines were measured using an ionization chamber under standardized condition. The entrance skin air kerma (ESAK) for Chest PA, Lumbar spine AP, Lumbar spine LAT, Pelvis AP, Abdomen AP, Skull AP and Skull LAT were calculated for at least 10 adult patients of average body mass (60 to 80 kg) for each projection. The obtained values were compared with international standards. Results: The highest film rejection rate reduction recorded after corrective actions from 9.15% to 6.8%. Mean ESAK values were less than international standards both before and after QC implementation in all projections but Chest PA projection. Maximum ESAK in Chest PA projection before corrective action was 0.55 mGy which was higher than the IAEA GL of 0.2 mGy. However, it was reduced to 0.25 mGy after QC tests on X- ray machine and using high kilovoltage (kV) technique. Conclusion: Proposed national GL of Thailand were obtained by estimating the 3rd quartile of the whole sample: Chest PA: 0.1 mGy, Lumbar Spine AP: 2.1 mGy, Lumbar Spine LAT: 6.3 mGy, Pelvis AP: 1.8 mGy, Abdomen: 1.5 mGy, Skull PA: 1.3 mGy and Skull LAT: 0.9 mGy. (author)

  2. Educational Virtual Environments as a Lens for Understanding both Precise Repeatability and Specific Variation in Learning Ecologies

    Science.gov (United States)

    Zuiker, Steven J.

    2012-01-01

    As a global cyberinfrastructure, the Internet makes authentic digital problem spaces like educational virtual environments (EVEs) available to a wide range of classrooms, schools and education systems operating under different circumstantial, practical, social and cultural conditions. And yet, if the makers and users of EVEs both have a hand in…

  3. Patient dosimetry in hysterosalpingography

    International Nuclear Information System (INIS)

    Khoury, H.J.; Maia, A.; Oliveira, M.; Kramer, R.; Drexler, G.

    2001-01-01

    The objectives of this study were to determine the entrance surface dose to the patient and to estimate the dose to the uterus and ovaries due to hysterosalpingography (HSG) diagnostic examinations performed in Recife-Pe, Brazil. The entrance doses were measured using four thermoluminescent dosimeters per patient, attached to anatomical landmarks on the patient's skin. The study was carried out on 25 patients between 21 and 45 years of age who underwent the HSG examinations in two training hospitals and one private radiodiagnostic institute. The number of exposures performed ranged from 4 to 15 radiographs per patient measured. Entrance surface doses varied between 4.99 and 36.6 mGy, with an average of 12.6mGy. The doses to the ovaries and uterus ranged from 0.80 mGy to 5.8 mGy and 1.10mGy to 8.05 mGy, respectively. (author)

  4. Effect of gamma irradiation at intermediate doses on the performance of reverse osmosis membranes

    International Nuclear Information System (INIS)

    Combernoux, Nicolas; Labed, Véronique; Schrive, Luc; Wyart, Yvan; Carretier, Emilie; Moulin, Philippe

    2016-01-01

    The goal of this study is to explain the degradation of Polyamide (PA) composite reverse osmosis membrane (RO) in function of the irradiation dose. Irradiations were performed with a gamma 60 Co source in wet conditions and under oxygen atmosphere. For different doses of 0.2 and 0.5 MGy with a constant dose rate of 0.5 kGy h −1 , RO membranes performances (NaCl retention, permeability) were studied before and after irradiation. ATR-FTIR, ion chromatography and gas chromatography were used to characterize structural modification. Results showed that the permeability of RO membranes irradiated at 0.2 MGy exhibited a small decrease, related to scissions of the PVA coating. However, retention did not change at this dose. At 0.5 MGy, permeability showed a large increase of a factor around 2 and retention began to decrease from 99% to 95%. Chromatography measurements revealed a strong link between permselectivity properties variation, ion leakage and oxygen consumption. Add to ATR-FTIR observations, these results emphasized that the cleavages of amide and ester bonds were observed at 0.5 MGy, more precisely the loss of hydrogen bonds between polyamide chains. By different analysis, modifications of the polysulfone layer occur until a dose of 0.2 MGy. - Highlights: • Irradiation of RO membranes at intermediate dose (0.2 and 0.5 MGy). • For a dose rate of 0.5 kGy h −1 RO membranes are radiation resistant until 0.2 MGy. • Cleavages of polymer bonds in the active layer at 0.5 MGy. • Decrease in permselectivity properties of the membrane at 0.5 MGy. • High oxygen consumption between 0.2 and 0.5 MGy related to the membranes degradation.

  5. Report of questionnaire concerning the conditions and exposure doses at thoracoabdominal radiography and CT

    International Nuclear Information System (INIS)

    2009-01-01

    Japan Association of Radiological Technologists, at 2 years after its presentation of the Guideline for Medical Radiation Exposure (2006), made a questionnaire in the title on its homepage on Nov. 6-Dec. 5, 2008, and this paper is its report. The questionnaire asked the conditions and exposure doses at thoracoabdominal radiography and CT: in the former, asked were conditions like the machine/detector, tube voltage, filter, incident angle, entrance plane dose (EPD) (mGy) etc., and 237 facilities including 56 public hospitals and 15 universities answered. EPD calculated by numerical dose determination was found to be 0.22 and 0.76 mGy at the frontal and lateral thoracic projection, respectively, which were less than the upper limit defined in International Atomic Energy Agency (IAEA) guidance (0.4 and 1.5 mGy). However, doses in 6 and 2.6% of facilities at the respective projection exceeded the IAEA levels. EPD at the frontal abdominal projection calculated was 2.22 mGy, and all facilities met with the IAEA demand level (<10 mGy). In the CT questionnaire, conditions asked were the machine manufacturer/brand, scanning mode and range, tube voltage, rotation time, beam width and pitch, slice width, CTDIvol (CT Dose Index weighted/pitch) (mGy) and so on, which 212 facilities involving 58 public hospitals and 14 universities answered. CTDIvol was found to be 91.7 mGy at head CT which greatly exceeded the maximal levels of International Commission of Radiological Protection (ICRP), IAEA and the Association (60, 50 and 65 mGy, respectively). CTDIvol at thoracic CT was 15.2 mGy (no standard upper limit at present), and at abdominal CT, 20.0 mGy (the same as the Association level). The latter suggested the suitable dose setting at this CT. Thus the problem at head CT was much highlighted here. (K.T.)

  6. Preliminary evaluation of exposures of computerized tomography patients in Latin America: IAEA project RLA/9/67; Avaliacao preliminar das exposicoes de pacientes em tomografia computadorizada na America Latina: Projeto IAEA RLA/9/67

    Energy Technology Data Exchange (ETDEWEB)

    Kodlulovich, S.; Silveira, V. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Khoury, H.J. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamcnto de Energia Nuclear; and others

    2013-07-01

    The aim of this study was to obtain preliminary values of reference levels in CT . Were sent to each country forms with information of radiological protection and routine CT protocols. The CT dose index and absorbed dose to organs was estimated from the technical data for each equipment . The results showed that the total number of examinations performed 92 % are adult patients and 8 % are children. The most frequent examination of the skull was adult (40 % ) and abdomen for children (42 % ) . About the service , 67 % of the equipment are multicut and 76 % have specific protocols for pediatric patients. The CTDI{sub vol} values for head exams of adults vary between 2 and 352 mGy for pediatric patients under 1 year 1-191 mGy under 7 years old 5-335 mGy. For chest values ranged from 3 to 26 mGy for adults, between 1 and 89 mGy for children under 1 year and between 3-114 mGy for children between 1 and 7 years. Exams of the abdomen/pelvis of adults the range was 3-47 mGy , between 4-90 mGy for children under 1 year and between 2-31 mGy for children between 1 and 7 years. This study showed that although there are pediatric protocols, there is a wide variation in values of CTDl{sub vol} indicating a high potential for dose reduction. This result requires immediate action for optimization and implementation of diagnostic reference values in Latin America.

  7. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  8. The effects of low dose radiation (LDR) on mice of immune function

    International Nuclear Information System (INIS)

    Feng Li; Deng Daping

    2007-01-01

    Objective: To find out the Effects of Low Dose Radiation(LDR) on mice of immune function. Methods: Through flow cytometry to observe and analyse the effects of the leukomonocyte. Through immunohistochemistry to study IL-2, TNF-α. Results: At dose of 100mGy the stimulative effect on CD 4 + cells, CD 8 + cells and NK activity was higher than that at other doses. At dose of 500mGy leukomonocyte activity was lower. At dose of 100mGy, the colorations about IL-2, TNF-α deepen. Conclusion: LDR could stimulate immune function, especially at dose of 100mGy. while at dose of 500mGy, radiation could restrain the leukomonocyte activity. (authors)

  9. Dosimetry for Patients undergoing Radiographic Examinations in Sudan

    International Nuclear Information System (INIS)

    Halato, M.A.; Kafi, S.T.; Ahmed, A.M.; Sid Ahamed, F.A.; Ibrahim, Z.; Suliman, M.F.; Suliman, I.I.

    2009-01-01

    In this study we estimated the entrance skin doses ESDs for patients undergoing selected diagnostic X -ray examinations in two large public hospitals in Khartoum state, Sudan. The study included the examinations of the chest posterior-anterior (PA) , skull antero-posterior (AP), skull Lateral (LAT) , Lumber spine AP/LAT, abdomen Intravenous urogram (IVU) and Pelvis AP. Totally, 241 patients were included in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μ Gy/mAs) and tube voltage (kVp). The estimated ESDs ranged from 0.18 - 1.05 mGy for chest PA, 0.98 - 3.48 mGy for Skull (AP), 0.66 - 2.75 mGy for skull (LAT), 1.22 - 4.35 mGy for abdomen (IVU), 1.18 - 5.75 mGy for Pelvis, 1.52 - 5.01 mGy Lumbar spine AP and 2.48 - 10.41 mGy for Lumbar spine (LAT). These values compare well with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose level for diagnostic radiology in Sudan

  10. Efficacy of everolimus with exemestane versus exemestane alone in Asian patients with HER2-negative, hormone-receptor-positive breast cancer in BOLERO-2.

    Science.gov (United States)

    Noguchi, Shinzaburo; Masuda, Norikazu; Iwata, Hiroji; Mukai, Hirofumi; Horiguchi, Jun; Puttawibul, Puttisak; Srimuninnimit, Vichien; Tokuda, Yutaka; Kuroi, Katsumasa; Iwase, Hirotaka; Inaji, Hideo; Ohsumi, Shozo; Noh, Woo-Chul; Nakayama, Takahiro; Ohno, Shinji; Rai, Yoshiaki; Park, Byeong-Woo; Panneerselvam, Ashok; El-Hashimy, Mona; Taran, Tetiana; Sahmoud, Tarek; Ito, Yoshinori

    2014-11-01

    The addition of mTOR inhibitor everolimus (EVE) to exemestane (EXE) was evaluated in an international, phase 3 study (BOLERO-2) in patients with hormone-receptor-positive (HR(+)) breast cancer refractory to letrozole or anastrozole. The safety and efficacy of anticancer treatments may be influenced by ethnicity (Sekine et al. in Br J Cancer 99:1757-62, 2008). Safety and efficacy results from Asian versus non-Asian patients in BOLERO-2 are reported. Patients were randomized (2:1) to 10 mg/day EVE + EXE or placebo (PBO) + EXE. Primary endpoint was progression-free survival (PFS). Secondary endpoints included overall survival, response rate, clinical benefit rate, and safety. Of 143 Asian patients, 98 received EVE + EXE and 45 received PBO + EXE. Treatment with EVE + EXE significantly improved median PFS versus PBO + EXE among Asian patients by 38 % (HR = 0.62; 95 % CI, 0.41-0.94). Median PFS was also improved among non-Asian patients by 59 % (HR = 0.41; 95 % CI, 0.33-0.50). Median PFS duration among EVE-treated Asian patients was 8.48 versus 4.14 months for PBO + EXE, and 7.33 versus 2.83 months, respectively, in non-Asian patients. The most common grade 3/4 adverse events (stomatitis, anemia, elevated liver enzymes, hyperglycemia, and dyspnea) occurred at similar frequencies in Asian and non-Asian patients. Grade 1/2 interstitial lung disease occurred more frequently in Asian patients. Quality of life was similar between treatment arms in Asian patients. Adding EVE to EXE provided substantial clinical benefit in both Asian and non-Asian patients with similar safety profiles. This combination represents an improvement in the management of postmenopausal women with HR(+)/HER2(-) advanced breast cancer progressing on nonsteroidal aromatase inhibitors, regardless of ethnicity.

  11. Evaluation of radiation dose during the percutaneous angioplasty for arteriovenous shunt assembling

    International Nuclear Information System (INIS)

    Ting, Chien-Yi; Wu, Wen-Shiann; Tang, Kuo-Ting; Wang, Hsin-Ell; Lin, Chun-Chih

    2017-01-01

    Percutaneous angioplasty (PTA) for dysfunctional hemodialysis is usually performed by radiologists, but not cardiologists, in Taiwan, so that the radiation dose in patients and physicians are usually unknown and related studies are rare. In this study, we are pioneering an investigation into the radiation dose in percutaneous angioplasty for arteriovenous shunt assembling and the effect of RADPAD device, a lead-free surgical drape containing Bi and Ba, on the decrease of a radiation dose in the non-targeted organs of the patient and also the operator. The radiation dose in a typical digital subtraction angiography (DSA) by the PTA protocol under a fixed field of view (FOV), was measured with optically simulated luminescent dosimeters arranged in a PIXY RS-102 anthropomorphic phantom. The results indicate that there is a significant dose reduction at the hands (0.022±0.002 mGy before treatment vs. 0.014±0.001 mGy after treatment; P=0.021), but not at the lens (0.027±0.003 mGy before treatment vs. 0.018±0.001 mGy after treatment; P=0.058), and the gonads (0.026±0.003 mGy before treatment vs. 0.020±0.001 mGy after treatment; P=0.058), of the cardiologist/operator after treatment with the RADPAD drape. At the patient's abdomen, the dose significantly decreased from 1.597±0.104 mGy to 0.031±0.002 mGy (P<0.001) after treated with the RADPAD shield. For the chest, lens and thyroid in the patient, the doses were respectively 0.154±0.100 mGy (compared to 0.049±0.001 mGy after treated with the RADPAD drape; P=0.0002), 0.066±0.001 mGy (compared to 0.021±0.001 mGy after the RADPAD treatment; P=0.009), and 0.208±0.002 mGy (compared to 0.042±0.003 mGy after shielded with the RADPAD drape; P<0.0001), which represents an apparent reduction in dose. However, no significant difference was found in the dose-area product between before (179.9±0.1mGy.cm 2 ) and after (177.4±0.1mGy.cm 2 ) the treatment (P=0.38). In conclusion, the RADPAD drape significantly reduced

  12. Eye Movements Behavior While Driving a Car: A Review

    Science.gov (United States)

    1978-10-01

    should be filtered if only the relevant information input is to be inveatigated. -13- The analysis of eye movements bahavior should be consi- dered... volunt rvtlv switch hi , attent on From one eve to the other (e.q. LACK, 19"’). The accomodation of the eve at a greater distance in car Jriving

  13. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  14. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  15. Study on human mesenchymal stem cells from bone marrow pretreated with low dose radiation

    International Nuclear Information System (INIS)

    Yang Yan; Wang Guangjun; Wang Juan

    2008-01-01

    Objective: To study effects of human bone marrow mesenchymal stem cells (hBM-MSC) from bone marrow pretreated with low dose radiation (LDR). Methods: The cells were the hBM-MSC. They were exposed to X rays at the dose of 50 mGy, 75 mGy, 100 mGy (dose rate 12.5 mGy/min). The growth curve, cell cycle and apoptosis of hBM-MSC treated by LDR were investigated. The content changes of stem cell factor(SCF), interleukin-6 (IL-6), macrophage colony stimulating factor(M-CSF) secreted by hBM-MSC after treated by LDR were determined by enzyme linked immunosorbent assay method. Results: The growth rates of hBM-MSC treated by LDR obviously increase from 72 h. The cell cycle and apoptosis were examined with FORTRAN Atomatic Checkout Systom. The results show that the G 0 /G 1 stage cells decrease after exposure to LDR, the percent of G 0 /G 1 stage cells of 75 mGy at 72 h is the lowest(30.86%). However, the S stage cells percentage gradually increase at 48 h and 72 h. The most one is 75 mGy group at 72 h, which reaches to 68.88%. The apoptosis percentages have increased tendency at 24 h and 48h in all dose groups, especially in 100 mGy at 24 h(25.99%), while have decreased tendency at 72 h and the most decreased group is the 50 mGy(6.8%), transient enhancement of apoptosis in the early stage and soon being decreased. The contents of SCF have increased tendency at 24 h, 48 h. As for IL-6, the contents in different dose groups at 24 h and 48 h have up-regulation. These groups, 50 mGy at 24 h, 48 h, 75 mGy at 24 h, 48 h, 100 mGy at 24 h have statistical difference compared with their control groups respectively. The content of IL-6 has greatest enhancement at dose of 50 mGy. The contents of M-SCF in all the groups at 24 h, 48 h and 72 h except for the 50 mGy dose at 72 h have also been found increased. The greatest increased content occur in the 75 mGy dose group at 72 h. Conclusion: This conclusion show that LDR has hormesis effect on hBM-MSC in cell growth, cell cycle and content

  16. Patient exposures in Swedish diagnostic radiology

    International Nuclear Information System (INIS)

    Bengtsson, G.; Blomgren, P.-G.; Bergman, K.; Aaberg, L.

    1977-01-01

    Variations in doses between individuals and hospitals are discussed. Mean values and collective doses for Sweden are estimated. The mean annual collective dose per individual was estimated as follows: thyroid 0.75 mGy; mammae 0.54 mGy; lungs 0.64 mGy; bone marrow 0.92 mGy; ovaries 0.68 mGy and testes 0.65 mGy. The genetically significant dose was estimated as 0.7 mGy, a doubling since 1955. The annual mean whole body dose calculated from the energy imparted was 1.00 mGy. These figures should be subject to errors of about a factor of 2, mainly originating from the poor sampling technique. Some simplified risk estimates relating to the various examinations are made using the mean organ doses. These estimates indicated that within a factor of 3 up or down, the overall cancer risk might be 10 -4 J -1 , that is, an imparted energy of 10 000 J would lead to one radiation induced cancer. The estimate would apply to all examinations except those on extremities. The estimate of radiation induced cancer, uncertain as it may be, totals 8 cases per million Swedes per year, which is small compared with the natural cancer incidence of about 2000 per million and year. No corresponding simplification using energy absorbed seemed possible concerning the genetic risks. The study shows that using available examination techniques a dose reduction by a factor of 2 or more should be po

  17. An investigation into CT radiation dose variations for head examinations on matched equipment

    International Nuclear Information System (INIS)

    Zarb, Francis; Foley, Shane; Toomey, Rachel; Rainford, Louise; Holm, Susanne; Evanoff, Michael G.

    2016-01-01

    This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n = 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDI vol -mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p ≤ 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC AUC 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality. (authors)

  18. Occupational and patient exposure in coronary angiography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Gafar, R.; Babikir, E.; Alsafi, K.; Suliman, I.I.

    2014-01-01

    Cardiac catheterization is the gold standard in the diagnosis and management of coronary artery diseases. The objectives of this study were to evaluate the radiation dose of patients and staff during cardiology procedures. Staff was monitored using thermoluminescence dosimeter (TLD) chips for 86 procedures. The mean patient dose was 2813.6 µGy m 2 and the mean fluoroscopic time was 4.8 min. The mean radiation doses for cardiologists were 0.9 mGy for the forehead, 0.92 mGy for the thyroid, 1.38 mGy for the chest, 1.28 mGy for the waist and 1.41 mGy for the hand. The mean radiation doses for assistants were 0.72 mGy for the chest, 0.82 mGy for the hand. High patient and staff exposure is due to lack of experience and protective equipment, exacerbated by a high workload. Interventional procedures remain operator dependent; therefore, continuous training is crucial. - Highlights: • Patients and staff radiation doses were evaluated during coronary angiography procedures. • Radiation doses were measured using calibrated TLD GR200A. • Radiation doses to patients and staff are comparable with previous studies. • Patient radiation doses fall below the threshold for radiation-induced skin injuries

  19. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  20. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    International Nuclear Information System (INIS)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-01-01

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  1. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  2. Uncovering the Repertoire of Endogenous Flaviviral Elements in Aedes Mosquito Genomes.

    Science.gov (United States)

    Suzuki, Yasutsugu; Frangeul, Lionel; Dickson, Laura B; Blanc, Hervé; Verdier, Yann; Vinh, Joelle; Lambrechts, Louis; Saleh, Maria-Carla

    2017-08-01

    Endogenous viral elements derived from nonretroviral RNA viruses have been described in various animal genomes. Whether they have a biological function, such as host immune protection against related viruses, is a field of intense study. Here, we investigated the repertoire of endogenous flaviviral elements (EFVEs) in Aedes mosquitoes, the vectors of arboviruses such as dengue and chikungunya viruses. Previous studies identified three EFVEs from Aedes albopictus cell lines and one from Aedes aegypti cell lines. However, an in-depth characterization of EFVEs in wild-type mosquito populations and individual mosquitoes in vivo has not been performed. We detected the full-length DNA sequence of the previously described EFVEs and their respective transcripts in several A. albopictus and A. aegypti populations from geographically distinct areas. However, EFVE-derived proteins were not detected by mass spectrometry. Using deep sequencing, we detected the production of PIWI-interacting RNA-like small RNAs, in an antisense orientation, targeting the EFVEs and their flanking regions in vivo The EFVEs were integrated in repetitive regions of the mosquito genomes, and their flanking sequences varied among mosquito populations. We bioinformatically predicted several new EFVEs from a Vietnamese A. albopictus population and observed variation in the occurrence of those elements among mosquitoes. Phylogenetic analysis of an A. aegypti EFVE suggested that it integrated prior to the global expansion of the species and subsequently diverged among and within populations. The findings of this study together reveal the substantial structural and nucleotide diversity of flaviviral integrations in Aedes genomes. Unraveling this diversity will help to elucidate the potential biological function of these EFVEs. IMPORTANCE Endogenous viral elements (EVEs) are whole or partial viral sequences integrated in host genomes. Interestingly, some EVEs have important functions for host fitness and

  3. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  4. Des personnages érigés en narrateurs : les voix over chez Joseph L. Mankiewicz (A Letter to Three Wives, All about Eve et The Barefoot Contessa

    Directory of Open Access Journals (Sweden)

    Alain Boillat

    2011-08-01

    Full Text Available L’auteur analyse dans une perspective narratologique trois films de Joseph L. Mankiewicz réalisés entre 1949 et 1954 (A Letter to Three Wives, All about Eve et The Barefoot Contessa afin d’observer les particularités qui résultent du recours à un ou plusieurs narrateurs (ou narratrices s’exprimant en voix over. L’accent est mis sur les implications de l’organisation énonciative complexe de ces productions cinématographiques en termes de relation du film au spectateur et de représentation des rapports de genre. Ces études de cas permettent de nuancer certains acquis issus du champ des théories de l’énonciation. Dans ces films où les voix over sont proférées par des acteurs qui incarnent par ailleurs un personnage visualisé, certaines interactions sont observables – interprétées notamment comme des relations de pouvoir – entre le statut des narrateurs et le niveau diégétique. La matérialité sonore est prise en compte dans le cas particulier de Letter to Three Wives, où la voix se transforme en bruit. Cet « effet spécial » est l’occasion de discuter un modèle « impersonnel » de l’énonciation filmique qui intègre, tout en tenant compte de la dimension technologique de l’enregistrement sonore, le pouvoir fondamentalement humanisant des manifestations vocales.

  5. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  6. 13C n.m.r. study of solvation mechanisms in the radiation-induced polymerization of vinyl ethers

    International Nuclear Information System (INIS)

    Deffieux, A.; Subira, F.; Stannett, V.T.

    1984-01-01

    A 13 C n.m.r. study of the microstructure of ethyl vinyl ether (EVE) and isopropyl vinyl ether (IPVE) polymers prepared under various experimental conditions and using chemical or γ-ray initiation has been made. Long stereo-sequence assignments were conducted for poly EVE allowing determination of the configurational statistics of propagation in the radiation-induced polymerization of EVE in low polar solvents. Stereo-sequence intensities are found in good agreement with the Markovian model. The results are considered as further support for the occurrence of a specific interaction between the growing active centres and the polymer chains. In the case of IPVE polymers much more important overlappings of the resonance patterns are observed thus preventing any similar detailed study. (author)

  7. Countermeasure against probabilistic blinding attack in practical quantum key distribution systems

    International Nuclear Information System (INIS)

    Qian Yong-Jun; Li Hong-Wei; He De-Yong; Yin Zhen-Qiang; Zhang Chun-Mei; Chen Wei; Wang Shuang; Han Zheng-Fu

    2015-01-01

    In a practical quantum key distribution (QKD) system, imperfect equipment, especially the single-photon detector, can be eavesdropped on by a blinding attack. However, the original blinding attack may be discovered by directly detecting the current. In this paper, we propose a probabilistic blinding attack model, where Eve probabilistically applies a blinding attack without being caught by using only an existing intuitive countermeasure. More precisely, our countermeasure solves the problem of how to define the bound in the limitation of precision of current detection, and then we prove security of the practical system by considering the current parameter. Meanwhile, we discuss the bound of the quantum bit error rate (QBER) introduced by Eve, by which Eve can acquire information without the countermeasure. (paper)

  8. Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

    Science.gov (United States)

    Chang, Lienard A; Miller, Donald L; Lee, Choonsik; Melo, Dunstana R; Villoing, Daphnée; Drozdovitch, Vladimir; Thierry-Chef, Isabelle; Winters, Sarah J; Labrake, Michael; Myers, Charles F; Lim, Hyeyeun; Kitahara, Cari M; Linet, Martha S; Simon, Steven L

    2017-12-01

    This study summarizes and compares estimates of radiation absorbed dose to the thyroid gland for typical patients who underwent diagnostic radiology examinations in the years from 1930 to 2010. The authors estimated the thyroid dose for common examinations, including radiography, mammography, dental radiography, fluoroscopy, nuclear medicine, and computed tomography (CT). For the most part, a clear downward trend in thyroid dose over time for each procedure was observed. Historically, the highest thyroid doses came from the nuclear medicine thyroid scans in the 1960s (630 mGy), full-mouth series dental radiography (390 mGy) in the early years of the use of x rays in dentistry (1930s), and the barium swallow (esophagram) fluoroscopic exam also in the 1930s (140 mGy). Thyroid uptake nuclear medicine examinations and pancreatic scans also gave relatively high doses to the thyroid (64 mGy and 21 mGy, respectively, in the 1960s). In the 21st century, the highest thyroid doses still result from nuclear medicine thyroid scans (130 mGy), but high thyroid doses are also associated with chest/abdomen/pelvis CT scans (18 and 19 mGy for males and females, respectively). Thyroid doses from CT scans did not exhibit the same downward trend as observed for other examinations. The largest thyroid doses from conventional radiography came from cervical spine and skull examinations. Thyroid doses from mammography (which began in the 1960s) were generally a fraction of 1 mGy. The highest average doses to the thyroid from mammography were about 0.42 mGy, with modestly larger doses associated with imaging of breasts with large compressed thicknesses. Thyroid doses from dental radiographic procedures have decreased markedly throughout the decades, from an average of 390 mGy for a full-mouth series in the 1930s to an average of 0.31 mGy today. Upper GI series fluoroscopy examinations resulted in up to two orders of magnitude lower thyroid doses than the barium swallow. There are

  9. Emergency CT head and neck imaging: effects of swimmer's position on dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Mueck, Fabian G.; Roesch, Sebastian; Geyer, Lucas; Scherr, Michael; Seidenbusch, Michael; Stahl, Robert; Deak, Zsuzsanna; Wirth, Stefan [LMU Klinikum Universitaet Muenchen (Germany). Inst. fuer Klinische Radiologie

    2014-05-15

    To compare the effects of different arm positions on dose exposure and image quality (IQ) in cervical spine CT after trauma in different patient groups. Patients in standard (STD = 126) and in swimmer's position (SWIM = 254) were included. Body mass index (BMI subgroup 1 = underweight to subgroup 4 = obese), anterior-posterior diameter (AP), left-right diameter (LR), area of an ellipse (AoE) and angle between the humeral heads (optimal STD < 3 , optimal SWIM > 10 ) were used as grouping criteria. Computed tomography dose index (CTDI) was documented. Two radiologists rated the IQ at three levels (CV1/2, CV4/5, CV7/T1) using a semi-quantitative scale (0 = not diagnostic, 1 = diagnostic with limitations, 2 = diagnostic without limitations). The Mann-Whitney U test correlations of grouping criteria with dose effects and intra-class correlation (ICC) were calculated. ICC was 0.87. BMI grouping showed the strongest correlation with dose effects: CTDI of optimal STD versus optimal SWIM positioning was 3.17 mGy versus 2.46 mGy (subgroup 1), 5.47 mGy versus 3.97 mGy (subgroup 2), 7.35 mGy versus 5.96 mGy (subgroup 3) and 8.71 mGy versus 8.18 mGy (subgroup 4). Mean IQ at CV7/T1 was 1.65 versus 1.23 (subgroup 1), 1.27 versus 1.46 (subgroup 2), 1.06 versus 1.46 (subgroup 3), 0.79 versus 1.5 (subgroup 4). Patients with a BMI > 20 kg/m{sup 2} benefited from both potential dose reduction and improved image quality at the critical cervicothoracic junction when swimmer's position was used. (orig.)

  10. Entrance radiation doses during paediatric cardiac catheterizations performed for diagnosis or the treatment of congenital heart disease

    International Nuclear Information System (INIS)

    Papadopoulou, D.; Yakoumakis, Em; Sandilos, P.; Thanopoulos, V.; Makri, Tr; Gialousis, G.; Houndas, D.; Yakoumakis, N.; Georgiou, Ev

    2005-01-01

    The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterizations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (D P ), the lateral entrance dose (D LAT ), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm 2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterizations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm 2 . Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs. (authors)

  11. Radiation pretreatments of cellulose materials for the enhancement of enzymatic hydrolysis

    International Nuclear Information System (INIS)

    Ait Si Mamar, S.; Hadjadj, A.

    1990-01-01

    The conversion of wheat straw agricultural cellulosic wastes to reducing sugars and glucose has been studied by pretreatments by acid hydrolysis and gamma radiolysis over the dose 0-2 MGy. The pretreatment of cellulosic wastes by gamma radiolysis in the presence of sulfuric acid solution shows that the reducing sugars yield increases with the irradiation dose. The effect of radiation degradation on cellulosic wastes between 0.1 MGy and 2 MGy shows the glucose and reducing sugars yields after enzymatic hydrolysis by cellulase vary with the dose. In the relatively low dose range, up to about 0.5 MGy, the reducing sugars yields vary slightly. For an acid hydrolysis followed by radiation at dose range below 0.5 MGy the reducing sugars yields are practically insensitive to radiation. On the other hand, the pretreatment by radiation in higher dose range from 0.5 to 2 MGy followed by enzymatic hydrolysis is effective for the conversion of cellulosic wastes into glucose. The radiation induced degradation of cellulose into glucose depends on the type of acid hydrolysis and on the enzymatic hydrolysis time by cellulase. Pre-irradiation in air is more effective than in acid solution. (author)

  12. Radiation pretreatments of cellulose materials for the enhancement of enzymatic hydrolysis

    Science.gov (United States)

    Mamar, S. Ait Si; Hadjadj, A.

    The conversion of wheat straw agricultural cellulosic wastes to reduning sugars and glucose has been studied by pretreatments by acid hydrolysis and gamma radiolysis over the dose 0-2 MGy. The pretreatment of cellulosic wastes by gamma radiolysis in the presence of sulfuric acid solution shows that the reducing sugars yield increases with the irradiation dose. The effect of radiation degradation on cellulosic wastes between 0.1 MGy and 2 MGy shows the glucose and reducing sugars yields after enzymatic hydrolysis by cellulase vary with the dose. In the relatively low dose range, up to about 0.5 MGy, the reducing sugars yields vary slightly. For an acid hydrolysis followed by radiation at dose range below 0.5 MGy the reducing sugars yields are practically insensitive to radiation. On the other hand, the pretreatment by radiation in higher dose range from 0.5 to 2 MGy followed by enzymatic hydrolysis is effective for the conversion of cellulosic wastes into glucose. The radiation induced degradation of cellulose into glucose depends on the type of acid hydrolysis and on the enzymatic hydrolysis time by cellulase. Pre-irradiation in air is more effective than in acid solution.

  13. Validation of the mother-generated index in Iran: A specific postnatal quality-of-life instrument

    Directory of Open Access Journals (Sweden)

    Roghayeh Khabiri

    2013-01-01

    Full Text Available Background: The mother-generated index (MGI is one of only a few existing specific questionnaires for assessing the postnatal quality of life (QoL. MGI is a single-form questionnaire that asks postnatal mothers to specify up to eight areas of their lives which have been affected by giving birth to a baby. Using this tool, it is possible to score and rank the QoL of mothers. This study aimed to validate the questionnaire for use in Iran. Methods : Forward translation was used to translate the questionnaire from English to Farsi (Persian. The questionnaire was then administered to a sample of postnatal women attending two teaching hospitals in Tehran, Iran. Face validity and criterion validity were performed to establish the validity for the Iranian version of the MGI. Face validity was assessed by asking women to indicate whether they understood the wording of the questions, how easy the questionnaire was, and so on. Criterion validity was examined using the Short Form 36-item (SF-36 Health Survey. It was hypothesized that the MGI would significantly correlate with the SF-36. Results: In all, 124 women were approached. Of these, 119 women were eligible and 96 women agreed to take part in the study. Face validity was good and all of the women found the MGI straightforward to complete; as criterion validity, the MGI scores and the subscales of the SF-36 were moderately correlated (for all subscales: Pearson r > 0.4; P < 0.001. The mean MGI primary score was 5.38 (SD = 3.05. Women who had comorbidity had significantly lower MGI scores than women without comorbidity (P = 0.04. Correlation between aggregate of comments and primary score was high (r = 0.68, P < 0.01. Conclusions: In general, the Iranian version of the MGI performed well and our data suggest that it is a valid measure to assess health-related QoL among postnatal women.

  14. Dose response relationship for unstable-type chromosome aberration rate of spleen cells from mice continuously exposed to low-dose-rate gamma-rays

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Khoda, Atsushi; Ichinohe, Kazuaki; Oghiso, Yoichi

    2007-01-01

    It has been reported that people who are chronically exposed to radiation such as nuclear facility workers and medical radiologists have slightly higher incidences of chromosome aberrations than non-exposed people. However, chronological changes of chromosome aberration rates related to accumulated doses and dose-rates for low dose-rate radiation exposures have not been well studied. Precise analyses of human populations are quite limited because confounding factors influence the results. For this reason, animal experiments are important for analyses. Mice were continuously exposed to gamma-rays at 400 mGy/22 hr/day for 10 days, 20 mGy/22 hr/day for about 400 days, and 1 mGy/22 hr/day for about 615 days under SPF conditions. Chronological changes of unstable-type chromosome aberration rates of spleen cells were observed along with accumulated doses at the middle dose rate and the two low-dose rates by conventional Giemsa-staining method. Aberrations such as dicentric chromosome, ring chromosome and fragment increased in a two-phase manner within 0-1.2 Gy and 2-8 Gy at 20 mGy/22 hr/day. They slightly increased up to 0.5 Gy at 1 mGy/22 hr/day. Aberration rates for 1, 2, 8 Gy at the 20 mGy/22 hr/day and for 0.5 Gy at 1 mGy/22 hr/day were 5.1, 9.6, 13.9 and 2.2 times higher than those of age-matched, non-irradiated control mice, respectively. Chromosome aberration rates at 400 mGy/22 hr/day were 2.7 times higher than that of 20 mGy/22 hr/day for the same total dose of 1.2 Gy. The results that unstable-type chromosome aberrations increased with accumulated dose of the low-dose rate radiation will be important to establish biological dosimetry for people who are chronically exposed to radiation. (author)

  15. Low-dose neutron dose response of zebrafish embryos obtained from the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Kong, E.Y.; Konishi, T.; Kobayashi, A.; Suya, N.; Cheng, S.H.; Yu, K.N.

    2015-01-01

    The dose response of embryos of the zebrafish, Danio rerio, irradiated at 5 h post fertilization (hpf) by 2-MeV neutrons with ≤100 mGy was determined. The neutron irradiations were made at the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility in the National Institute of Radiological Sciences (NIRS), Chiba, Japan. A total of 10 neutron doses ranging from 0.6 to 100 mGy were employed (with a gamma-ray contribution of 14% to the total dose), and the biological effects were studied through quantification of apoptosis at 25 hpf. The responses for neutron doses of 10, 20, 25, and 50 mGy approximately fitted on a straight line, while those for neutron doses of 0.6, 1 and 2.5 mGy exhibited neutron hormetic effects. As such, hormetic responses were generically developed by different kinds of ionizing radiations with different linear energy transfer (LET) values. The responses for neutron doses of 70 and 100 mGy were significantly below the lower 95% confidence band of the best-fit line, which strongly suggested the presence of gamma-ray hormesis. - Highlights: • Neutron dose response was determined for embryos of the zebrafish, Danio rerio. • Neutron doses of 0.6, 1 and 2.5 mGy led to neutron hormetic effects. • Neutron doses of 70 and 100 mGy accompanied by gamma rays led to gamma-ray hormesis

  16. Covert Channels and Simple Timed Mix-Firewalls

    National Research Council Canada - National Science Library

    Newman, Richard

    2004-01-01

    .... Initial work considered a simple model where an observer (Eve) was restricted to counting the number of messages leaving a Mix configured as a firewall guarding the enclave with one malicious sender (Alice) and some other naive senders (Clueless's). Here, we consider the case where Eve can distinguish between multiple destinations, and the senders can select to which destination their message (if any) is sent each clock tick.

  17. The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis

    International Nuclear Information System (INIS)

    Wieser, A.; Debuyst, R.; Fattibene, P.

    2005-01-01

    The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60 Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose

  18. Diagnostic reference levels in intraoral radiology: From the laboratory to clinical practice

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, E.; Martinez-Beneyto, Y.; Velasco, F.; Parra, C.; Canteras, M.

    2010-01-01

    To determine the diagnostic reference levels (DRLs) for obtaining a diagnostic image in the normal conditions of clinical practice and to explain the differences between the levels found and the DRLs obtained in other experimental conditions, suggesting that there has been a reduction in the European Union (EU) recommended levels. A total of 2296 official reports on dental surgeries from 16 Spanish autonomous regions compiled during 2008 were studied. A mean DRL of 3.3 mGy was determined: 2.6 mGy for installations using direct digital systems, 3.4 mGy for those using indirect systems, 4.4 mGy for those using Ultra-speed film and 3.7 mGy for those using Insight. The DRLs found in this survey are below the EU recommended values but far above previously described values, possibly because all the different systems were considered and because values refer to those of the normal work conditions of clinical practice. (authors)

  19. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  20. Atrazine is primarily responsible for the toxicity of long-term exposure to a combination of atrazine and inorganic arsenic in the nigrostriatal system of the albino rat.

    Science.gov (United States)

    Bardullas, Ulises; Giordano, Magda; Rodríguez, Verónica Mireya

    2013-01-01

    Chronic and simultaneous exposure to a variety of chemicals present in the environment is an unavoidable fact. However, given the complexity of studying chemical mixtures, most toxicological studies have focused on the effects of short-term exposure to single substances. The aim of this study was to evaluate the effects on the nigrostriatal system of the chronic, simultaneous exposure to two widely distributed substances that have been identified as potential dopaminergic system toxicants, inorganic arsenic (iAs) and atrazine (ATR). Six groups of rats were treated daily for one year with atrazine (10mg ATR/kg), inorganic arsenic (0.5 or 50mgiAs/L of drinking water), or a combination of ATR+0.5mgiAs/L or ATR+50mgiAs/L. The 50mgiAs/L group showed locomotor hypoactivity, while all treatments decreased motor coordination in contrast no effects of treatment were found on the place and response learning tasks. Regarding markers for liver and muscle damage, there were no differences between groups in creatine kinase (CK) or aspartate transaminase (AST) activities, while decreases in lactate dehydrogenase (LDH) levels were found in some exposed groups. The striatal DA content was significantly reduced in ATR, 0.5mgiAs/L, ATR+0.5mgiAs/L, and ATR+50mgiAs/L groups, in comparison to the control group. The number of mesencephalic tyrosine hydroxylase positive cells decreased in the ATR and ATR+0.5mgiAs/L groups compared to the control. In contrast, immunoreactivity to cytochrome oxidase was reduced compared to the control in all treated groups, except for the group treated with 0.5iAsmg alone. Our results indicate that ATR has deleterious effects on dopaminergic neurons and that the combination of ATR and iAs does not exacerbate these effects. © 2013 Elsevier Inc. All rights reserved.

  1. A novel dendrimer based on poly (L-glutamic acid) derivatives as an efficient and biocompatible gene delivery vector

    International Nuclear Information System (INIS)

    Zeng Xin; Pan Shirong; Wang Chi; Wen Yuting; Wu Hongmei; Wang Cuifeng; Wu Chuanbin; Feng Min; Li Jie

    2011-01-01

    Non-viral gene delivery systems based on cationic polymers have faced limitations related to their relative low gene transfer efficiency, cytotoxicity and system instability in vivo. In this paper, a flexible and pompon-like dendrimer composed of poly (amidoamine) (PAMAM) G4.0 as the inner core and poly (L-glutamic acid) grafted low-molecular-weight polyethylenimine (PLGE) as the surrounding multiple arms was synthesized (MGI dendrimer). The novel MGI dendrimer was designed to combine the merits of size-controlled PAMAM G4.0 and the low toxicity and flexible chains of PLGE. In phosphate-buffered saline dispersions the well-defined DNA/MGI complex above a N/P ratio of 30 showed good stability with particle sizes of approximately 200 nm and a comparatively low polydispersity index. However, the particle size of the DNA/25 kDa polyethylenimine (DNA/PEI 25K) complex was larger than 700 nm under the same salt conditions. The shielding of the compact amino groups at the periphery of flexible PAMAM and biocompatible PLGE chains in MGI resulted in a dramatic decrease of the cytotoxicity compared to native PAMAM G4.0 dendrimer. The in vitro transfection efficiency of DNA/MGI dendrimer complex was higher than that of PAMAM G4.0 dendrimer. Importantly, in serum-containing medium, DNA/MGI complexes at their optimal N/P ratio maintained the same high levels of transfection efficiency as in serum-free medium, while the transfection efficiency of native PAMAM G4.0, PEI 25K and Lipofectamine 2000 were sharply decreased. In vivo gene delivery of pVEGF165/MGI complex into balloon-injured rabbit carotid arteries resulted in significant inhibition of restenosis by increasing VEGF165 expression in local vessels. Therefore, the pompon-like MGI dendrimer may be a promising vector candidate for efficient gene delivery in vivo.

  2. DNA alterations and effects on growth and reproduction in Daphnia magna during chronic exposure to gamma radiation over three successive generations

    International Nuclear Information System (INIS)

    Parisot, Florian; Bourdineaud, Jean-Paul; Plaire, Delphine; Adam-Guillermin, Christelle; Alonzo, Frédéric

    2015-01-01

    Highlights: • We exposed three successive generations of Daphnia magna to chronic gamma radiation. • We examined DNA alterations and effects on survival, growth and reproduction. • DNA alterations were accumulated over a generation and transmitted to the progeny. • Effects on survival and reproduction, and delay in growth increased over generations. - Abstract: This study examined chronic effects of external Cs-137 gamma radiation on Daphnia magna exposed over three successive generations (F0, F1 and F2) to environmentally relevant dose rates (ranging from 0.007 to 35.4 mGy h −1 ). Investigated endpoints included survival, growth, reproduction and DNA alterations quantified using random-amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Results demonstrated that radiation effects on survival, growth and reproduction increased in severity from generation F0 to generation F2. Mortality after 21 days at 35.4 mGy h −1 increased from 20% in F0 to 30% in F2. Growth was affected by a slight reduction in maximum length at 35.4 mGy h −1 in F0 and by reductions of 5 and 13% in growth rate, respectively, at 4.70 and 35.4 mGy h −1 in F2. Reproduction was affected by a reduction of 19% in 21 day-fecundity at 35.4 mGy h −1 in F0 and by a delay of 1.9 days in brood release as low as 0.070 mGy h −1 in F2. In parallel, DNA alterations became significant at decreasing dose rates over the course of F0 (from 4.70 mGy h −1 at hatching to 0.007 mGy h −1 after ∼21 days) and from F0 to F2 (0.070 mGy h −1 at hatching to 0.007 mGy h −1 after ∼21 days), demonstrating their rapid accumulation in F0 daphnids and their transmission to offspring generations. Transiently more efficient DNA repair leading to some recovery at the organism level was suggested in F1, with no effect on survival, a slight reduction of 12% in 21 day-fecundity at 35.4 mGy h −1 and DNA alterations significant at highest dose rates only. The study improved our understanding of

  3. DNA alterations and effects on growth and reproduction in Daphnia magna during chronic exposure to gamma radiation over three successive generations

    Energy Technology Data Exchange (ETDEWEB)

    Parisot, Florian [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France); Bourdineaud, Jean-Paul [UMR 5805 EPOC – OASU, Station marine d’Arcachon, Université Bordeaux 1, Arcachon 33120 (France); Plaire, Delphine; Adam-Guillermin, Christelle [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France); Alonzo, Frédéric, E-mail: frederic.alonzo@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France)

    2015-06-15

    Highlights: • We exposed three successive generations of Daphnia magna to chronic gamma radiation. • We examined DNA alterations and effects on survival, growth and reproduction. • DNA alterations were accumulated over a generation and transmitted to the progeny. • Effects on survival and reproduction, and delay in growth increased over generations. - Abstract: This study examined chronic effects of external Cs-137 gamma radiation on Daphnia magna exposed over three successive generations (F0, F1 and F2) to environmentally relevant dose rates (ranging from 0.007 to 35.4 mGy h{sup −1}). Investigated endpoints included survival, growth, reproduction and DNA alterations quantified using random-amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Results demonstrated that radiation effects on survival, growth and reproduction increased in severity from generation F0 to generation F2. Mortality after 21 days at 35.4 mGy h{sup −1} increased from 20% in F0 to 30% in F2. Growth was affected by a slight reduction in maximum length at 35.4 mGy h{sup −1} in F0 and by reductions of 5 and 13% in growth rate, respectively, at 4.70 and 35.4 mGy h{sup −1} in F2. Reproduction was affected by a reduction of 19% in 21 day-fecundity at 35.4 mGy h{sup −1} in F0 and by a delay of 1.9 days in brood release as low as 0.070 mGy h{sup −1} in F2. In parallel, DNA alterations became significant at decreasing dose rates over the course of F0 (from 4.70 mGy h{sup −1} at hatching to 0.007 mGy h{sup −1} after ∼21 days) and from F0 to F2 (0.070 mGy h{sup −1} at hatching to 0.007 mGy h{sup −1} after ∼21 days), demonstrating their rapid accumulation in F0 daphnids and their transmission to offspring generations. Transiently more efficient DNA repair leading to some recovery at the organism level was suggested in F1, with no effect on survival, a slight reduction of 12% in 21 day-fecundity at 35.4 mGy h{sup −1} and DNA alterations significant at highest

  4. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    Science.gov (United States)

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  5. The Characteristics of Air Pollutants during Two Distinct Episodes of Fireworks Burning in a Valley City of North China.

    Directory of Open Access Journals (Sweden)

    Yang Song

    Full Text Available The elevation and dissipation of pollutants after the ignition of fireworks in different functional areas of a valley city were investigated.The Air Quality Index (AQI as well as inter-day and intra-day concentrations of various air pollutants (PM10, PM2.5, SO2, NO2, CO, O3 were measured during two episodes that took place during Chinese New Year festivities.For the special terrain of Jinan, the mean concentrations of pollutants increased sharply within 2-4 h of the firework displays, and concentrations were 4-6 times higher than the usual levels. It took 2-3 d for the pollutants to dissipate to background levels. Compared to Preliminary Eve (more fireworks are ignited on New Year's Eve, but the amounts of other human activities are also lesser, the primary pollutants PM2.5, PM10, and CO reached higher concentrations on New Year's Eve, and the highest concentrations of these pollutants were detected in living quarters. All areas suffered from serious pollution problems on New Year's Eve (rural = urban for PM10, but rural > urban for PM2.5. However, SO2 and NO2 levels were 20%-60% lower in living quarters and industrial areas compared to the levels in these same areas on Preliminary Eve. In contrast to the other pollutants, O3 concentrations fell instead of rising with the firework displays.Interactions between firework displays and other human activities caused different change trends of pollutants. PM2.5 and PM10 were the main pollutants, and the rural living quarter had some of the highest pollution levels.

  6. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    Science.gov (United States)

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  7. Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE)

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Oda, Seitaro; Nakaura, Takeshi; Yuki, Hideaki; Hirata, Kenichiro; Namimoto, Tomohiro; Sakabe, Daisuke; Hatemura, Masahiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Honjo, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Honjo, Kumamoto (Japan)

    2017-06-15

    To investigate the usefulness of modifying scanning parameters based on the size-specific dose estimate (SSDE) for a breast-dose reduction for chest CT. We scanned 26 women with a fixed volume CT dose index (CTDI{sub vol}) (15 mGy) and another 26 with a fixed SSDE (15 mGy) protocol (protocol 1 and 2, respectively). In protocol 2, tube current was calculated based on the patient habitus obtained on scout images. We compared the mean breast dose and the inter-patient breast dose variability and performed linear regression analysis of the breast dose and the body mass index (BMI) of the two protocols. The mean breast dose was about 35 % lower under protocol 2 than protocol 1 (10.9 mGy vs. 16.8 mGy, p < 0.01). The inter-patient breast dose variability was significantly lower under protocol 2 than 1 (1.2 mGy vs. 2.5 mGy, p < 0.01). We observed a moderate negative correlation between the breast dose and the BMI under protocol 1 (r = 0.43, p < 0.01); there was no significant correlation (r = 0.06, p = 0.35) under protocol 2. The SSDE-based protocol achieved a reduction in breast dose and in inter-patient breast dose variability. (orig.)

  8. Evaluation of pediatrics entrance surface air kerma during chest X-ray examinations in some Khartoum hospitals

    International Nuclear Information System (INIS)

    Mohamed, Hassan Ishag Yahya

    2015-10-01

    The aim of this study was to determine the amount of entrance surface air kerma dose in air that can reflect the amount of the risk that the children, are subjected to. The parameters that are involved in this project are x-ray tube current (mA), exposure time (sec.), and focal skin distance (FSD) in cm. ESAK is calculated using the equation: ESAK=(Output (mGy/mAs) x (100/FSD) 2 X mAs) for different examination of different patients. 65 cases were involved in this study, the results show that the ESAK mean value (0.18±0.07) mGy, (0.06±0.07) mGy, (0.045±0.017) mGy and (0.049±0.013) mGy at the hospitals (IBNIOF Omdurman, police, clinic doctor) respectively. IBNIOF presented the highest ESAK (0.18±0.07) mGy, while it was lowest in police (0.045±0.017) mGy. The estimated ESAK value were within the established international reference dose values and also the values obtained in pervious studies however, variations were observed in ESAK values among hospitals under study which could be due to the differences in exposure parameters used. Also tube output has some effect on obtained ESAK. (author)

  9. Radiation and mental retardation

    International Nuclear Information System (INIS)

    Pochin, E.E.

    1988-01-01

    The editorial comments on a report published by the Radiation Effects Research Foundation in Hiroshima updating information on the induction of mental changes in the light of the revised and more detailed estimate of doses of radiation during pregnancies received by those exposed at Hiroshima and Nagasaki. The estimated risks are little changed. The likelihood of a threshold for exposure during the 16th to 25th week is confirmed-at 700 mGy (with a lower 95% confidence interval of 200 mGy). For the more sensitive time between the eighth to 15th weeks a linear model with no threshold still gives a statistically adequate fit to the data. Now, however, if linear models are tested without the constraint of postulating a threshold of zero, fits are obtained indicating substantial thresholds below which mental retardation would not result. When data on all children are included the maximum likelihood threshold value averages about 250 mGy on the different criteria tested (with mean 95% confidence intervals of 0 and 550 mGy). Or if the analyses exclude five children with conditions that themselves sometimes cause mental retardation a threshold of about 400 mGy is indicated (with mean 95% confidence intervals of 150 and 600 mGy). (author)

  10. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  11. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells

    Science.gov (United States)

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-01

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation.

  12. Paradise Lost: Difference between Adam and Eve’s Lament on Leaving Paradise - A Contrastive Analysis

    Directory of Open Access Journals (Sweden)

    Sara Torres Servín

    2013-01-01

    Full Text Available The difference between Adam and Eve’s lament on leaving Paradise in Milton’s Paradise Lost is striking in its contrastive content and depth. This paper analyzes the difference that exists between the feelings and spiritual attitudes that Adam and Eve express on the occasion when they are informed by the angel Michael that they have to abandon the Garden of Eden. It is a comparison of their lament in order to understand the contrast of the two attitudes that Milton wove in the tapestry that Paradise Lost is. The paper also explores male and female roles in Paradise Lost and concludes that Adam and Eve are equal yet different, that difference being the cause of their contrastive ways of expressing their sorrow. Adam and Eve manifest two contrastive worldviews in opposition, one spiritual (heavenly, and the other material (earthly.

  13. Investigation of LiF, Mg and Ti (TLD-100 Reproducibility

    Directory of Open Access Journals (Sweden)

    Sadeghi M.

    2015-12-01

    Full Text Available LiF, Mg and Ti cubical TLD chips (known as TLD-100 are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC were obtained 4 times by irradiating them to doses of 81 mGy (two times, 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  14. Coronary cineangiography and ionizing radiation exposure to patients: analysis of primary and secondary beam

    International Nuclear Information System (INIS)

    Ramirez, Alfredo; Leyton, Fernando; Silva, Ana Maria; Farias, Eric

    2001-01-01

    The purpose of this work was to determine the level of exposure dose to patients during coronariographies in different areas of body. This study has presented the medical surveillance of 18 cases and the radiation monitoring of these patients by TLD in thyroid and pelvis (secondary beam) and, in the right and left scapular region (primary beam) for each one of these procedures. The ionizing radiation received was 215 ± 200 mGy in left scapular region (range 1-710) and 255±213 mGy in the right scapular region (range 22-635) p=NS. In the pelvic region the ionizing radiation was 0,22±0,06 mGy and in the thyroid region was 3,62±2,44 mGy

  15. Coronary cineangiography and ionizing radiation exposure to patients: analysis of primary and secondary beam; Cineangiografia coronaria y radiacion ionizante a pacientes. Analisis en haz primario y secundario

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Alfredo; Leyton, Fernando; Silva, Ana Maria; Farias, Eric [Universidad de Chile, Santiago (Chile). Hospital Clinico; Gamarra, Jorge; Oyarzun, Carlos [Comision Chilena de Energia Nuclear (CCHEN), Santiago (Chile)

    2001-07-01

    The purpose of this work was to determine the level of exposure dose to patients during coronariographies in different areas of body. This study has presented the medical surveillance of 18 cases and the radiation monitoring of these patients by TLD in thyroid and pelvis (secondary beam) and, in the right and left scapular region (primary beam) for each one of these procedures. The ionizing radiation received was 215 {+-} 200 mGy in left scapular region (range 1-710) and 255{+-}213 mGy in the right scapular region (range 22-635) p=NS. In the pelvic region the ionizing radiation was 0,22{+-}0,06 mGy and in the thyroid region was 3,62{+-}2,44 mGy.

  16. Baseline characteristics in the Bardoxolone methyl EvAluation in patients with Chronic kidney disease and type 2 diabetes mellitus: the Occurrence of renal eveNts (BEACON) trial.

    Science.gov (United States)

    Lambers Heerspink, Hiddo J; Chertow, Glenn M; Akizawa, Tadao; Audhya, Paul; Bakris, George L; Goldsberry, Angie; Krauth, Melissa; Linde, Peter; McMurray, John J; Meyer, Colin J; Parving, Hans-Henrik; Remuzzi, Giuseppe; Christ-Schmidt, Heidi; Toto, Robert D; Vaziri, Nosratola D; Wanner, Christoph; Wittes, Janet; Wrolstad, Danielle; de Zeeuw, Dick

    2013-11-01

    Type 2 diabetes mellitus (T2DM) is the most important contributing cause of end-stage renal disease (ESRD) worldwide. Bardoxolone methyl, a nuclear factor-erythroid-2-related factor 2 activator, augments estimated glomerular filtration. The Bardoxolone methyl EvAluation in patients with Chronic kidney disease and type 2 diabetes mellitus: the Occurrence of renal eveNts (BEACON) trial was designed to establish whether bardoxolone methyl slows or prevents progression to ESRD. Herein, we describe baseline characteristics of the BEACON population. BEACON is a randomized double-blind placebo-controlled clinical trial in 2185 patients with T2DM and chronic kidney disease stage 4 (eGFR between 15 and 30 mL/min/1.73 m(2)) designed to test the hypothesis that bardoxolone methyl added to guideline-recommended treatment including inhibitors of the renin-angiotensin-aldosterone system slows or prevents progression to ESRD or cardiovascular death compared with placebo. Baseline characteristics (mean or percentage) of the population include age 68.5 years, female 43%, Caucasian 78%, eGFR 22.5 mL/min/1.73 m(2) and systolic/diastolic blood pressure 140/70 mmHg. The median urinary albumin:creatinine ratio was 320 mg/g and the frequency of micro- and macroalbuminuria was 30 and 51%, respectively. Anemia, abnormalities in markers of bone metabolism and elevations in cardiovascular biomarkers were frequently observed. A history of cardiovascular disease was present in 56%, neuropathy in 47% and retinopathy in 41% of patients. The BEACON trial enrolled a population heretofore unstudied in an international randomized controlled trial. Enrolled patients suffered with numerous co-morbid conditions and exhibited multiple laboratory abnormalities, highlighting the critical need for new therapies to optimize management of these conditions.

  17. 18FDG PET in a pregnant patient

    International Nuclear Information System (INIS)

    Chatterton, Barry

    2006-01-01

    A 26-year-old pregnant female presented with cervical adenopathy which was shown on biopsy to be Hodgkin's disease. As she had some systemic symptoms, It was decided to further stage her disease, with the options being allowing the pregnancy to continue, or terminating the pregnancy and treating immediately. To keep the radiation dose as low as possible, the administered dose of l8 FDG was reduced giving a total estimated dose to the fetus as 3.2 mGy and l37 Cs used as the source for attenuation correction rather than CT (dose estimated as 0.15mGy instead of 1.5 mGy) Total dose to the fetus was estimated as 3.4mGy. ICRP indicates that termination of pregnancy is not justified for radiation doses less than 100mGy. The findings confirm that an indicated PET scan may be performed in pregnancy at acceptable radiation dose. Relatively straightforward modification of the standard scanning protocol will reduce the estimated fetal dose. Copyright (2006) The Australian and New Zealand Society of Nuclear Medicine

  18. Eavesdropping on the "Ping-Pong" Quantum Communication Protocol Freely in a Noise Channel

    OpenAIRE

    Deng, Fu-Guo; Li, Xi-Han; Li, Chun-Yan; Zhou, Ping; Zhou, Hong-Yu

    2005-01-01

    We introduce an attack scheme for eavesdropping the ping-pong quantum communication protocol proposed by Bostr$\\ddot{o}$m and Felbinger [Phys. Rev. Lett. \\textbf{89}, 187902 (2002)] freely in a noise channel. The vicious eavesdropper, Eve, intercepts and measures the travel photon transmitted between the sender and the receiver. Then she replaces the quantum signal with a multi-photon signal in a same state, and measures the photons return with the measuring basis with which Eve prepares the ...

  19. Fault Tolerance in Critical Information Systems

    Science.gov (United States)

    2001-05-01

    that provides an inte- grated editing and analysis environment through the use of the Adobe FrameMaker document processor [1] and the Z/Eves theorem... FrameMaker document processor provid- ing the special character set for Z just as it would any other character set (such as mathe- matical symbols). Zeus...happens to use the LaTeX Z language definition, so Zeus processes the Framemaker spec- ification and outputs the LaTeX translation to Z/Eves for

  20. Security of differential-phase-shift quantum key distribution against individual attacks

    International Nuclear Information System (INIS)

    Waks, Edo; Takesue, Hiroki; Yamamoto, Yoshihisa

    2006-01-01

    We derive a proof of security for the differential-phase-shift quantum key distribution protocol under the assumption that Eve is restricted to individual attacks. The security proof is derived by bounding the average collision probability, which leads directly to a bound on Eve's mutual information on the final key. The security proof applies to realistic sources based on pulsed coherent light. We then compare individual attacks to sequential attacks and show that individual attacks are more powerful

  1. Results of tooth enamel EPR dosimetry for population living in the vicinity of the Semipalatinsk nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, K. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan)], E-mail: kassym@hiroshima-u.ac.jp; Ivannikov, A. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Medical Radiological Research Center, Obninsk, 249036 (Russian Federation); Apsalikov, K. [Scientific-Research Institute for Radiation Medicine and Ecology, Semipalatinsk 490050 (Kazakhstan); Zhumadilov, Zh. [Semipalatinsk State Medical Academy, Semipalatinsk 490050 (Kazakhstan); Zharlyganova, D. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Stepanenko, V.; Skvortsov, V. [Medical Radiological Research Center, Obninsk, 249036 (Russian Federation); Berekenova, G. [Scientific-Research Institute for Radiation Medicine and Ecology, Semipalatinsk 490050 (Kazakhstan); Toyoda, S. [Department of Applied Physics Faculty of Science Okayama University of Science, 700-0005 (Japan); Endo, S.; Tanaka, K. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Miyazawa, C. [School of Dentistry, Ohu University, Koriyama-shi, Fukushima Pref. 963-8611 (Japan); Hoshi, M. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan)

    2007-07-15

    The method of electron paramagnetic resonance (EPR) dosimetry was used on human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the Nuclear Test Site (SNTS) in Semipalatinsk region, Kazakhstan. Measured teeth were extracted according to medical indications. In total, 105 tooth enamel samples were analyzed, including eight tooth samples from control settlement Kokpekty, which is located 400 km to the Southeast from SNTS and was not subjected to any radioactive contamination. It was found that the excess doses obtained after subtraction of the contribution of natural background radiation ranged up to about 440 mGy for residents of Dolon, whose tooth enamel was formed before 1949, and do not exceed 100 mGy for younger residents. For residents of Mostik, excess doses do not exceed 100 mGy for all ages except in one resident, for whom an extremely high dose of 1250 mGy was registered. For Bodene settlement, excess doses higher than 100 mGy were obtained for two samples from the residents having enamel formed before 1949. An extremely high dose (2800{+-}400 mGy) was obtained for one resident of Semipalatinsk City. The average excess dose for Semipalatinsk samples with enamel formation before 1949 was determined close to the average excess dose for tooth enamel samples from Dolon village.

  2. Histological variations in liver of freshwater fish Oreochromis mossambicus exposed to 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Sadiq Bukhari, A.; Syed Mohamed, H.E.; Broos, K.V.; Stalin, A.; Singhal, R.K.; Venubabu, P.

    2012-01-01

    The irradiation effect of 60 Co at the three dose level of 3 mGy, 30 mGy and 300 mGy on the histology of liver of the freshwater fish Oreochromis mossambicus was investigated. The liver of O. mossambicus was dissected out and processed for light microscopy studies. 60 Co exposed O. mossambicus were found to result in several alterations in the histoarchitecture of liver. The alterations included mild congestion of blood vessels, structural alteration, cellular swelling, vacuolation and necrotic liver cells, indicating a definite response to 60 Co irradiation. The results suggest that the liver of O. mossambicus exposed to 60 Co were structurally altered with increasing dose levels. It is to record that alteration in the liver does not affect the physiology, behaviour or lethality of the individuals. Self regulating mechanisms would have influenced the liver to remain sustained. To confirm the same further studies in the direction by increasing dose level is required. - Highlights: ► Fish Oreochromis mossambicus irradiated to the dose of 3 mGy, 30 mGy and 300 mGy. ► Histoarchitecture of liver altered with increasing dose levels of 60 Co. ► Alteration in the liver does not affect the physiology, behaviour or lethality. ► Self regulating mechanisms might have prevented from Lethality. ► HSI index value for exposed group reported ( 60 Co.

  3. Investigating the embryo/larval toxic and genotoxic effects of {gamma} irradiation on zebrafish eggs

    Energy Technology Data Exchange (ETDEWEB)

    Simon, O., E-mail: olivier.simon@irsn.fr [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Massarin, S. [Laboratoire de Modelisation Environnementale, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 159, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Coppin, F. [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Hinton, T.G. [Service d' Etude du Comportement des Radionucleides dans les Ecosystemes, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 159, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Gilbin, R. [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France)

    2011-11-15

    Eggs/larval of freshwater fish (Danio rerio) were exposed to low dose rates of external gamma radiation (from 1 to 1000 mGy d{sup -1}) over a 20-day period, with the objective of testing the appropriateness of the 10 mGy d{sup -1} guideline suggested by the IAEA. The present study examines different endpoints, mortality and hatching time and success of embryos as well as the genotoxicity of {gamma}-irradiations (after 48 h). The 20-day embryo-larval bioassay showed an enhanced larval resistance to starvation after chronic exposure to {gamma} irradiation (from low 1 mGy d{sup -1} to high dose rate 1000 mGy d{sup -1}) and an acceleration in hatching time. Gamma irradiation led to increased genotoxic damage Ito zebrafish egg (40-50% DNA in tail in Comet assay) from the lowest dose rate (1 mGy d{sup -1}). Possible mechanisms of {gamma} radiotoxicity and implications for radioprotection are discussed. - Highlights: > Relevant information on the {gamma} radiation impact on early life stage biota is scarce. > The eggs of zebrafish Danio rerio were selected as biological model. > We test the appropriateness of the 10 mGy d{sup -1} guideline (IAEA). > We observed effects measured at individual levels (starvation, hatching time). > Chronic gamma irradiation led to increased genotoxic damage to zebrafish egg. > {gamma} radiotoxicity mechanisms and implications for radioprotection are discussed.

  4. Clinical application of low-dose spiral CT for orthodontics

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Shu Huang; Lin FeiFei; Li Zhiyong; Sun Jie

    2009-01-01

    Objective: To determine the effect of reducing the value of mA or kV on the image quality and the radiation dose of the patients undergoing low-dose spiral CT for orthodontics. Methods: Thirty patients were divided into three groups, each group has 10 patients. They were group 1 (80 kV and 200 mA), group 2 (120 kV and 80 mA), group 3 (120 kV and 200 mA) The volume CT dose index (CTDI) was recorded and the average dose-length produce (DLP) was calculated in three groups,respectively. Image quality of three groups were compared and scored by two radiologists, and the results were statistically analysed. Results: The CTDI and DLP of 80 kV group (group 2) were 8.7 mGy and (36.80 ± 3.60) mGy · cm, respectively, those of 80 mA group (group 3) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively, and those of conventional-dose group (group 1) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively. There was no significant difference among three groups in diagnostic image quality. Conclusions: Low-dose spiral CT for orthodontics, especially the low-kV scan, may decrease the radiation exposure and guarantee the image quality. (authors)

  5. No-signaling quantum key distribution: solution by linear programming

    Science.gov (United States)

    Hwang, Won-Young; Bae, Joonwoo; Killoran, Nathan

    2015-02-01

    We outline a straightforward approach for obtaining a secret key rate using only no-signaling constraints and linear programming. Assuming an individual attack, we consider all possible joint probabilities. Initially, we study only the case where Eve has binary outcomes, and we impose constraints due to the no-signaling principle and given measurement outcomes. Within the remaining space of joint probabilities, by using linear programming, we get bound on the probability of Eve correctly guessing Bob's bit. We then make use of an inequality that relates this guessing probability to the mutual information between Bob and a more general Eve, who is not binary-restricted. Putting our computed bound together with the Csiszár-Körner formula, we obtain a positive key generation rate. The optimal value of this rate agrees with known results, but was calculated in a more straightforward way, offering the potential of generalization to different scenarios.

  6. Foot strike pattern in children during shod-unshod running.

    Science.gov (United States)

    Latorre Román, Pedro Ángel; Balboa, Fernando Redondo; Pinillos, Felipe García

    2017-10-01

    The purpose of this study was to determine the foot strike patterns (FSPs) and neutral support (no INV/EVE and no foot rotation) in children, as well as to determine the influence of shod/unshod conditions and sex. A total of 713 children, aged 6 to 16 years, participated in this study (Age=10.28±2.71years, body mass index [BMI]=19.70±3.91kg/m 2 , 302 girls and 411 boys). A sagittal and frontal-plane video (240Hz) was recorded using a high-speed camcorder, to record the following variables: rearfoot strike (RFS), midfoot strike (MFS), forefoot strike (FFS), inversion/eversion (INV/EVE) and foot rotation on initial contact. RFS prevalence was similar between boys and girls in both shod and unshod conditions. In the unshod condition there was a significant reduction (p<0.001) of RFS prevalence both in boys (shod condition=83.95% vs. 62.65% unshod condition) and in girls (shod condition=87.85% vs. 62.70% unshod condition). No significant differences were found in INV/EVE and foot rotation between sex groups. In the unshod condition there was a significant increase (p<0.001) of neutral support (no INV/EVE) both in boys (shod condition=12.55% vs. 22.22% unshod condition) and in girls (shod condition=17.9% vs. 28.15% unshod condition). In addition, in the unshod condition there is a significant reduction (p<0.001) of neutral support (no foot rotation) both in boys (shod condition=21.55% vs. 11.10% unshod condition) and in girls (shod condition=21.05% vs. 11.95% unshod condition). In children, RFS prevalence is lower than adult's population. Additionally, barefoot running reduced the prevalence of RFS and INV/EVE, however increased foot rotation. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Everolimus plus exemestane versus bevacizumab-based chemotherapy for second-line treatment of hormone receptor-positive metastatic breast cancer in Greece: An economic evaluation study.

    Science.gov (United States)

    Kourlaba, Georgia; Rapti, Vasiliki; Alexopoulos, Athanasios; Relakis, John; Koumakis, Georgios; Chatzikou, Magdalini; Maniadakis, Nikos; Georgoulias, Vassilis

    2015-08-05

    The objective of our study was to conduct a cost-effectiveness (CE) study of combined everolimus (EVE) and exemestane (EXE) versus the common clinical practice in Greece for the treatment of postmenopausal women with HR+/HER2- advanced breast cancer (BC) progressing on nonsteroidal aromatase inhibitors (NSAI). The combinations of bevacizumab (BEV) plus paclitaxel (PACL) and BEV plus capecitabine (CAPE) were selected as comparators. A Markov model, consisting of three health states, was used to describe disease progression and evaluate the CE of the comparators from a third-party payer perspective over a lifetime horizon. Efficacy and safety data as well as utility values considered in the model were extracted from the relevant randomized Phase III clinical trials and other published studies. Direct medical costs referring to the year 2014 were incorporated in the model. A probabilistic sensitivity analysis was conducted to account for uncertainty and variation in the parameters of the model. Primary outcomes were patient survival (life-years), quality-adjusted life years (QALYs), total direct costs and incremental cost-effectiveness ratios (ICER). The discounted quality-adjusted survival of patients treated with EVE plus EXE was greater by 0.035 and 0.004 QALYs, compared to BEV plus PACL and BEV plus CAPE, respectively. EVE plus EXE was the least costly treatment in terms of drug acquisition, administration, and concomitant medications. The total lifetime cost per patient was estimated at €55,022, €67,980, and €62,822 for EVE plus EXE, BEV plus PACL, and BEV plus CAPE, respectively. The probabilistic analysis confirmed the deterministic results. Our results suggest that EVE plus EXE may be a dominant alternative relative to BEV plus PACL and BEV plus CAPE for the treatment of HR+/HER2- advanced BC patients failing initial therapy with NSAIs.

  8. Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

    Directory of Open Access Journals (Sweden)

    Esen Nsikan U

    2015-07-01

    Full Text Available Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State, Nigeria. Materials and Methods In total, six examinations were performed on 720 patients in this study.   CALDose_X5 software program was used in estimating ESDs based on patients’ information and technical exposure parameters. Results The estimated ESDs ranged from 0.59 to 0.61 mGy for PA and RLAT projections of the thorax, respectively. ESDs for the AP and RLAT projections of the cranium were 1.65 and 1.48 mGy, respectively. Also, ESD values for the AP view of the abdomen and pelvis were 1.89 and 1.88 mGy, respectively. The mean effective dose was within the range of 0.021-0.075 mGy for the thorax (mean= 0.037, 0.008-0.045 mGy for the cranium (mean= 0.016, 0.215-0.225 mGy for the abdomen (mean= 0.219 and 0.101-0.119 mGy for the pelvis (mean= 0.112. Conclusion The obtained results were comparable to the international reference dose levels, except for the PA projection of the thorax. Therefore, quality assurance programs are required in diagnostic X-ray units of Nigeria hospitals. The obtained findings add to the available data and can help authorities establish reference dose levels for diagnostic radiography in Nigeria.

  9. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    International Nuclear Information System (INIS)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion

  10. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa [Istanbul University, Istanbul (Turkmenistan)

    2015-12-15

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.

  11. Agents of Change: Interpreters as Witnesses of Transition

    Directory of Open Access Journals (Sweden)

    Kristina Mullamaa

    2014-08-01

    Full Text Available In this article we would like to share the preliminary results of our on-going research on the memories of interpreters. From 2011-2012 we have carried out in-depth interviews with representatives of two different samples: experienced dialogue interpreters a in Estonia and  b in Sweden, most of whom have worked from the 1960s till today. This article sums up the preliminary results on the sample from Estonia. The focus is on the development of the interpreter´s role as reflecting the changes in society, cultural and social practices. As for the theoretical background, we view the processes within the framework of Transition Studies (cf. Lauristin, Vihalemm 2010;  Kennedy 2002. The methodological framework is ethnographic research. More specifically:  we combine narrative studies and memory research ( Kõresaar, Kirss 2004; Riessman 1993, Middleton, Brown 2005, Gilbert 2008; method:  semi-structured interviews (cf. Nunan 1992, Van Maanen 1983, Gilbert 2008. The analysis of our on-going research also enables us to test and share with our readers the pros and cons of the chosen methodology and methods.

  12. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    International Nuclear Information System (INIS)

    Wang, H; Wang, Y; Weng, H

    2015-01-01

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan

  13. Computed Tomography (CT) radiation dose in children: A survey to propose regional diagnostic reference levels in Greater Accra-Ghana

    International Nuclear Information System (INIS)

    Addo, Patience

    2016-07-01

    The aim of this work was to assess the doses delivered to paediatric patients during computed tomography (CT) examinations of the head, chest and abdomen, and establishing regional diagnostic reference levels (RDRLs) for four age groups. The patient data, technique parameters and dose descriptors collected include: age, sex, tube voltage, tube current, rotation time, slice thickness, scan length, volume CT dose index (CTDI_v_o_l) and dose length product (DLP). Currently, paediatric CT examinations account for 11% of radiation exposure. For the paediatric age groups; < 1 year, (1-5 years), (6-10 years) and (11-15 years), the proposed RDRLs for head in terms of CTDI_v_o_l are (28, 38, 48 and 86 mGy) and in terms of DLP; (395, 487, 601, 1614 mGy cm) respectively. For Chest examinations, proposed RDRLs in terms of CTDI_v_o_l are (1 and 5 mGy) and in terms of DLP; (18 and 110 mGy cm) for age groups; < 1 year and (1-5 years) respectively. For Abdomino-pelvic examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 3 and 10 mGy) and in terms of DLP; (71, 120 and 494 mGy cm) for age groups; < 1 year, (1-5 years) and (6-10 years) respectively. For abdomen examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 5 and 5 mGy) and in terms of DLP; (83, 124 and 233 mGy cm) for age groups; < 1 year, (1-5 years) and (11-15 years) respectively. RDRLs have been proposed for CTDI_v_o_l and DLP for head, chest, abdomen and Abdomino-pelvic paediatric CT examinations in this study. An optimisation is required for 11-15 years age group for the DLP values which was higher than their corresponding international DRLs. For an effective optimization of patient protection a trade-off between image quality and patients doses studies should be investigated. (au)

  14. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    International Nuclear Information System (INIS)

    Nawfel, RD; Young, G

    2016-01-01

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  15. Average glandular dose in digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Olgar, T. [Ankara Univ. (Turkey). Dept. of Engineering Physics; Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2012-10-15

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  16. Average glandular dose in digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Olgar, T.; Universitaetsklinikum Leipzig AoeR; Kahn, T.; Gosch, D.

    2012-01-01

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  17. Standardised approach to optimisation

    International Nuclear Information System (INIS)

    Warren-Forward, Helen M.; Beckhaus, Ronald

    2004-01-01

    Optimisation of radiographic images is said to have been obtained if the patient has achieved an acceptable level of dose and the image is of diagnostic value. In the near future, it will probably be recommended that radiographers measure patient doses and compare them to reference levels. The aim of this paper is to describe a standardised approach to optimisation of radiographic examinations in a diagnostic imaging department. A three-step approach is outlined with specific examples for some common examinations (chest, abdomen, pelvis and lumbar spine series). Step One: Patient doses are calculated. Step Two: Doses are compared to existing reference levels and the technique used compared to image quality criteria. Step Three: Appropriate action is taken if doses are above the reference level. Results: Average entrance surface doses for two rooms were as follows AP Abdomen (6.3mGy and 3.4mGy); AP Lumbar Spine (6.4mGy and 4.1mGy) for AP Pelvis (4.8mGy and 2.6mGy) and PA chest (0.19mGy and 0.20mGy). Comparison with the Commission of the European Communities (CEC) recommended techniques identified large differences in the applied potential. The kVp values in this study were significantly lower (by up to lOkVp) than the CEC recommendations. The results of this study have indicated that there is a need to monitor radiation doses received by patients undergoing diagnostic radiography examinations. Not only has the assessment allowed valuable comparison with International Diagnostic Reference Levels and Radiography Good Practice but has demonstrated large variations in mean doses being delivered from different rooms of the same radiology department. Following the simple 3-step approach advocated in this paper should either provide evidence that department are practising the ALARA principle or assist in making suitable changes to current practice. Copyright (2004) Australian Institute of Radiography

  18. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.

  19. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    Energy Technology Data Exchange (ETDEWEB)

    Nawfel, RD; Young, G [Brigham & Women’s Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  20. Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across europe

    International Nuclear Information System (INIS)

    Zarb, F.; McEntee, M.; Rainford, L.

    2012-01-01

    This work recommends dose reference levels (DRLs) for abdomen, chest and head computerised tomography (CT) examinations in Malta as the first step towards national CT dose optimisation. Third quartiles volume CT dose index values for abdomen: 12.1 mGy, chest: 13.1 mGy and head: 41 mGy and third quartile dose-length product values for abdomen: 539.4, chest: 492 and head: 736 mGy cm -1 are recommended as Maltese DRLs derived from this first Maltese CT dose survey. These values compare well with DRLs of other European countries indicating that CT scanning in Malta is consistent with standards of good practice. Further work to minimise dose without affecting image quality and extending the establishment of DRLs for other CT examinations is recommended. (authors)

  1. Victims of stalking in India: A study of girl college students in Tirunelveli City

    Directory of Open Access Journals (Sweden)

    Jaishankar Karuppannan

    2007-01-01

    Full Text Available The word 'stalking' was not commonly known in India, until Priyadharshini Mattoo's case (1996 hit the headlines. Eve teasing, a colloquial word for gender harassment is popularly known and Tamil Nadu Prohibition of Eve-Teasing Act, 1998 on that was developed after the brutal killing of a girl named Sarika Shah in Chennai. Though, stalking is there in the past, it was not acknowledged with this terminology and it was always merged with Eve teasing. On the other hand, stalking is much graver than Eve teasing and it is an obsessive behaviour. After the Matoo's case, the Indian Criminal Justice System awoke and the National Commission for Women is ready with a draft Bill (Sexual Assault Prevention Bill to make the Indian Penal Code more effective against the menace of stalkers. Research studies related to stalking in India are sparse and there is a need to study this phenomenon in depth. This paper presents some results from a study of stalking victims among Girl College students at Tirunelveli City, Tamil Nadu, India. In-depth questionnaire data are drawn on to investigate the course and nature of prolonged stalking in 150 self-defined victims. Findings indicate a pattern of repeated intrusions, the stalking harassment methods, lack of reporting behaviour, and effects of stalking on the victims.

  2. As filhas de Eva: religião e relações de gênero na justiça medieval portuguesa Eve's daughters: religion and gender relations in the portuguese medieval justice

    Directory of Open Access Journals (Sweden)

    Edlene Oliveira Silva

    2011-04-01

    Full Text Available Este artigo analisa as representações de mulheres presentes nas Ordenações Afonsinas, código jurídico português elaborado no século XV que definiu e classificou detalhadamente vários crimes considerados tipicamente femininos e estipulou punições rigorosas. Dentre esses delitos, trataremos de alguns aspectos do adultério, do concubinato e da alcovitagem. Informado pelas representações de gênero, o discurso jurídico do Estado monárquico luso legitimou a perseguição empreendida pela Igreja às mulheres "desviantes". O olhar da justiça era influenciado pelo imaginário religioso cristão e medieval, repleto de ideias patriarcais e misóginas que associavam o feminino ao arquétipo da Eva pecadora, a primeira mulher que se deixou seduzir pelos ardis malignos do demônio.This article analyzes the representations of women in the Ordenações Afonsinas, the Portuguese juridical code elaborated in the 15th century that defined and classified in detail several crimes considered typically feminine, and that stipulated rigorous punishments. Among those crimes, we will discuss some aspects of adultery, concubinage, and panderism. Informed by gender representations, the juridical discourse of the Lusitanian monarchical State legitimated the persecution of "deviating" women undertaken by the Church. The view of justice was influenced by Christian/medieval religious imaginary, full of patriarchal and misogynistic ideas that associated the feminine to Eve's archetype of the sinner, the first woman to be seduced by the Devil's evil artifices.

  3. TALE-mediated modulation of transcriptional enhancers in vivo.

    Science.gov (United States)

    Crocker, Justin; Stern, David L

    2013-08-01

    We tested whether transcription activator-like effectors (TALEs) could mediate repression and activation of endogenous enhancers in the Drosophila genome. TALE repressors (TALERs) targeting each of the five even-skipped (eve) stripe enhancers generated repression specifically of the focal stripes. TALE activators (TALEAs) targeting the eve promoter or enhancers caused increased expression primarily in cells normally activated by the promoter or targeted enhancer, respectively. This effect supports the view that repression acts in a dominant fashion on transcriptional activators and that the activity state of an enhancer influences TALE binding or the ability of the VP16 domain to enhance transcription. In these assays, the Hairy repression domain did not exhibit previously described long-range transcriptional repression activity. The phenotypic effects of TALER and TALEA expression in larvae and adults are consistent with the observed modulations of eve expression. TALEs thus provide a novel tool for detection and functional modulation of transcriptional enhancers in their native genomic context.

  4. Cultural differences in postnatal quality of life among German-speaking women - a prospective survey in two countries.

    Science.gov (United States)

    Grylka-Baeschlin, Susanne; van Teijlingen, Edwin; Gross, Mechthild M

    2014-08-15

    Assessment of quality of life after childbirth is an important health-outcome measurement for new mothers and is of special interest in midwifery. The Mother-Generated Index (MGI) is a validated instrument to assess postnatal quality of life. The tool has not been applied for making a cross-cultural comparison before. This study investigated (a) responses to the MGI in German-speaking women in Germany and Switzerland; and (b) associations between MGI scores on the one hand and maternity and midwifery care on the other. A two-stage survey was conducted in two rural hospitals 10 km apart, on opposite sides of the German-Swiss border. The questionnaires included the MGI and questions on socio-demographics, physical and mental health and maternity care, and were distributed during the first days after birth and six weeks postpartum. Parametric and non-parametric tests were computed with the statistical programme SPSS. A total of 129 questionnaires were returned an average of three days after birth and 83 in the follow-up after seven weeks. There were no statistically significant differences in the MGI scores between the German and the Swiss women (p = 0.22). Significantly more favourable MGI scores were found associated with more adequate information during pregnancy (p = 0.02), a more satisfactory birth experience (p German-speaking women were higher than those in other studies reported previously. Thus the tool may be able to detect differences in postnatal quality of life among women with substantially divergent cultural backgrounds. Shortcomings in maternity and midwifery care were detected, as for example the inadequate provision of information during pregnancy, a lack of individualised postpartum care during the hospital stay and insufficient support for exclusively breastfeeding mothers. The MGI is an appropriate instrument for maternity care outcome measurement in cross-cultural comparison research.

  5. Electron beam irradiation effects on carbon fiber reinforced PEEK composite

    International Nuclear Information System (INIS)

    Sasuga, Tsuneo; Hagiwara, Miyuki; Odajima, Tosikazu; Sakai, Hideo; Nakakura, Toshiyuki; Masutani, Masahiro.

    1987-03-01

    Carbon fiber(CF) reinforced composites, using polyarylether-sulfone (PES) or polyarylether-ether-ketone (PEEK) as matrix material, were prepared and their electron beam irradiation effects were studied on the basis of changes in mechanical and dynamic viscoelastic properties and observation of fracture surfaces. The flexural strength of PES-CF composite decreased to 70 % of the initial strength after the irradiation of 3 MGy and 40 % after 15 MGy. The change in the profile of stress-strain (S-S) curves and fractographic observation by electron microscopy indicated that this composite irradiated with over 3 MGy was fractured by delamination caused by to the degradation of matrix polymer. The mechanical properties of PEEK-CF composite were scarcely decreased even after irradiated up to 180 MGy and this composite showed very high radiation resistance. The change in the profile of S-S curves and fractographic observation showed that this composite fractured due to destruction of fiber in the dose range less than 180 MGy, indicating that PEEK was excellent matrix material used in high radiation field. PEEK-PES-CF composite which was composed of the carbon fibers coated with PES solution showed less radiation resistance compared with PEEK-CF composite; the flexural strength decreased to 85 % of the initial value after the irradiation with 90 MGy. It was revealed from the changes in the profile of S-S curve that the specimen irradiated over 120 MGy was fractured due to not only fiber destruction but delamination. Deterioration mechanism of PEEK-PES-CF composite was studied by dynamic viscoelastic measurements in connection with the damage on matrix-fiber interface. It was suggested that the deterioration in mechanical properties of this composite was caused by the degradation of PES that coated on the surface of the carbon fibers. (author)

  6. Effect of low dose radiation on expression of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow

    International Nuclear Information System (INIS)

    Yang Yan; Wang Guanjun; Zhu Jingyan; Wang Juan

    2008-01-01

    Objective: To study the changes of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow (BM-MSC) pretreated with low dose radiation (LDR). Methods: The cultured P4 and P5 BM-MSCs were exposed to X rays at the doses of 50, 75 and 100 mGy (dose rate 12.5 mGy·min -1 ). The changes of levels of stem cell factor (SCF), IL-6, macrophage colony-stimulating factor (M-CSF) secreted by BM- MSCs pretreated with LDR were determined by ELISA method. Results: As compared with control group at the same time, the levels of SCF in experimental group had a tendency of increasing after 24 h and 48 h radiation, but only in 75 mGy group the SCF level was obviously increased (P<0.05). The levels of IL-6 in 50 and 75 mGy groups at 24 h and 48 h, in 100 mGy group at 24 h were obviously increased compared with control group (P< 0.05). The levels of M-CSF in all the groups at 24 h, 48 h and 72 h except for the 50 mGy dose at 72 h were also increased (P<0.05), it increased markedly in 75 mGy dose group at 72 h. Conclusion: LDR has hormesis effect on BM-MSCs. After LDR, the BM-MSCs grow faster and in a certain phase the expression levels of hematopoietic growth factors are increased. (authors)

  7. Adaptive response of apoptosis in EL-4 lymphoma cells induced by low dose radiation and its mechanism

    International Nuclear Information System (INIS)

    Liu Shuchun; Gong Pingsheng; Wang Zhicheng; Sun Liguang; Gong Shouliang

    2008-01-01

    EL-4 lymphoma cells were irradiated with the inductive doses (D1: 25-200 mGy, dose rate: 12.5mGy/min) and the challenging dose (D2:0.5-3.0 Gy, dose rate: 287 mGy/min), and the time interval between D1 and D2 was 6 h. The percentage of cell apoptosis and the expressive levels of cell apoptosis-associated gene pro- reins were measured with flow cytometry. The percentages of cell apoptosis in the D1 + D2 group with 25-100 mGy (D1) and 1.5 Gy (D2) or 75 mGy (D1) and 25-200 mGy (D2) were significantly lower than those in the D2 group. As compared with the D2 group, the positive percentage of cell Bcl-2 protein expression increased somewhat, and Bax decreased significantly, meanwhile the ratio of Bcl-2/Bax increased significantly and p53 decreased somewhat in D1 + D2 group with 25-100 mGy (D1) and 1.5 Gy (D2). The adaptive response of EL-4 lymphoma cell apoptosis could be induced by pre-irradiation with 25-100 mGy. Meantime, the expressive levels of cell apoptosis-associated gene Bcl-2, Bax and p53 proteins could change accordingly with cell apoptosis. These gene protein changes may play an important role in the mechanism of the adaptive response. (authors)

  8. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  9. Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

    Science.gov (United States)

    Cornfeld, Daniel; Israel, Gary; Detroy, Ezra; Bokhari, Jamal; Mojibian, Hamid

    2011-03-01

    The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDI(vol)), dose-length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups. The mean CTDI(vol) and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3-9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of -257 mGy × cm [54-460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic to muscle contrast-to-noise ratio were not different between the two groups. Subjectively, one reviewer preferred the non-ASIR images and one found the images equivalent. Both reviewers believed the images were of diagnostic quality. A 29% decrease in CTDI(vol) and a 20% decrease in DLP were obtained in scans with ASIR compared with scans without ASIR, without a quantitative loss of image quality.

  10. Reference dose levels for dental panoramic radiography in Anyang City

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipment.

  11. Evaluation of external and internal irradiation on uranium mining enterprise staff by tooth enamel EPR spectroscopy

    Science.gov (United States)

    Zhumadilov, Kassym; Ivannikov, Alexander; Khailov, Artem; Orlenko, Sergei; Skvortsov, Valeriy; Stepanenko, Valeriy; Kuterbekov, Kairat; Toyoda, Shin; Kazymbet, Polat; Hoshi, Masaharu

    2017-11-01

    In order to estimate radiation effects on uranium enterprise staff and population teeth samples were collected for EPR tooth enamel dosimetry from population of Stepnogorsk city and staff of uranium mining enterprise in Shantobe settlment (Akmola region, North of Kazakhstan). By measurements of tooth enamel EPR spectra, the total absorbed dose in the enamel samples and added doses after subtraction of the contribution of natural background radiation are determined. For the population of Stepnogorsk city average added dose value of 4 +/- 11 mGy with variation of 51 mGy was obtained. For the staff of uranium mining enterprise in Shantobe settlment average value of added dose 95 +/- 20 mGy, with 85 mGy variation was obtained. Higher doses and the average value and a large variation for the staff, probably is due to the contribution of occupational exposure.

  12. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  13. Radiation Measurement And Risk Estimation For Pediatric Patients During Routine Diagnostic Examination

    International Nuclear Information System (INIS)

    Bushra, E.; Sulieman, A.; Osman, H.

    2011-01-01

    The aim of the present work was to evaluate Entrance Surface Dose (ESD) to the patient using Thermo luminescence dosimeters (TLD) during some common routine pediatrics X-ray examinations in main pediatrics hospitals in Sudan. ESD and Effective Dose (E) for pediatrics have been carried out for 250 patients undergoing five different examinations. The mean ESD ranged for neonates ranged between 0.17 mGy-0.30 mGy per radiograph with scattered thyroid dose 0.01 to 0.19 mGy. The risk of radiation induced cancer of was 0.13 x 10-6.

  14. Occupational external radiation exposure in the GDR in 1976

    International Nuclear Information System (INIS)

    Rothe, W.

    1980-01-01

    In 1976 a total of 36,794 occupationally exposed persons were monitored by the National Board of Nuclear Safety and Radiation Protection, using film badges. The monthly over-exposures (more than 4 mGy) totalled 415. In 11 cases the monthly exposure exceeded 30 mGy and 6 annual exposure values were in the range of 50 to 120 mGy. An attempt has been made to assess the annual collective and annual per caput doses for the exposed population as a whole and some subgroups without completely summing up the individual exposure data. (author)

  15. Evaluation of experimental animal biological state at exposure to low-dose ionizing radiation

    International Nuclear Information System (INIS)

    Rozanov, V.A.; Rejtarova, T.Je.; Chernyikov, G.B.; Timoshevs'ka, Je.V.; Kozozojeva, O.O.

    1997-01-01

    New approaches to quantitative evaluation of ionizing radiation absorbed dose within the low-dose range (up to 400 mGy) according to the degree of the organism biological response was developed. The purpose of the stage of the work published in Communication 1 is to evaluate the shifts in the animal behaviour and cellular composition of the blood at irradiation by the dose of 100,200 and 400 mGy. Distinct dose dependence of behaviour reactions and hematological indices within the dose range of 100-400 mGy was not noted

  16. Radiation hormesis of radish using an X-ray photography device

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Asahikawa Kousei Hospital, Hokkaido (Japan)

    2000-07-01

    Radiation hormesis was studied at an X-ray photography room. Seed of radish (Kaiwaredaikon) was irradiated by X-ray, from 10 to 3000 mGy. Since the growth of plant was the highest around 500 mGy, 100 seeds were irradiated at a dose of 500 mGy. Fifty seeds were selected and the growth rate was measured after 1 and 2 weeks. After 2 weeks, the growth of the seeds irradiated (129{+-}5 mm) was found to be higher than those without irradiation (115{+-}5 mm). (author)

  17. 2013 MDEQ-FEMA Rankin-Simpson Co. Lidar Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fugro as a subconsultant to MGI was authorized to undertake this project, as a part of Work Order No. 112, dated November 1, 2012, issued to MGI in accordance with...

  18. Magnetic stratigraphy of the Ordovician in the lower reach of the Kotuy River: the age of the Bysy-Yuryakh stratum and the rate of geomagnetic reversals on the eve of the superchron

    Science.gov (United States)

    Pavlov, V. E.; Tolmacheva, T. Yu.; Veselovskiy, R. V.; Latyshev, A. V.; Fetisova, A. M.; Bigun, I. V.

    2017-09-01

    Until recently, the existing data prevented the geophysicists from accurately dating the Bysy-Yuryakh stratum, which outcrops in the middle reach of the Kotuy River, constraining the time of its formation to a wide interval from the end of the Late Cambrian to the beginning of the Silurian. The obtained paleomagnetic data unambiguously correlate the Bysy-Yuryakh stratum to the Nyaian regional stage and constrain its formation, at least a considerable part of it, by the Tremadocian. This result perfectly agrees with the data on the Bysy-Yuryakh conodonts studied in this work and yields a spectacular example of the successful application of paleomagnetic studies in solving important tasks of stratigraphy and, correspondingly, petroleum geology. Within the Bysy-Yuryakh stratum, we revealed a large normal-polarity interval corresponding to the long (>1 Ma) period when the geomagnetic reversals were absent. This result, in combination with the data for the Tremadocian and Middle-Upper Cambrian sequences of the other regions, indicates that (1) the rate of occurrence of the geomagnetic reversals on the eve of the Ordovician Moyero superchron of reversed polarity was at most one reversal per Ma; (2) the superchron does not switch on instantaneously but is preceded by a certain gradual change in the operation conditions of the dynamo mechanism which, inter alia, manifests itself by the reduction of the frequency of geomagnetic reversals with the approach of the superchron. This finding supports the views according to which a process preparing the establishment of the superchrons takes place at the core-mantle boundary.

  19. Disainikaart : Portugal / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2009-01-01

    Portugali arhitektidest, disaineritest, disainifirmadest. Arhitektide Eduardo Souto de Moura (sünd. 1952) ja Alvaro Joaquim de Meio Siza Vieira (sünd. 1933) looming. Firmadest Corque, Mytto, Pedroso & Os-rio, TemaHome, Mood, Munna, Mambo, Delightfulli

  20. Disainikaart : Itaalia / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2009-01-01

    Itaalia disaineritest, disainifirmadest, arhitektidest. Renzo Piano (1937), Aldo Rossi (1931-1997), Alessandro Mendini (1931), Giorgio de Chirico (1888-1978), Federico Fellini (1920-1993), Gaetano Pesce, Ferrari, Alessi, Dolce & Gabbana, Artemide

  1. Disainikaart : Island / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2009-01-01

    Islandi disaineritest, disainifirmadest, arhitektidest. Katrin Olina, Margrét Hardardóttir ja Steve Christer (Studio Granda), Guđjón Samúelsson (1887-1950), Ingibjörg Hanna Bjarnadottir, Hrafnkell Birgisson, Studio Bility jt.

  2. Trepp = Stair / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2006-01-01

    Rakvere Vallimäe trepist. Laste vestlus trepil. Projekt: Kavakava. Autorid: Heidi Urb, Siiri Vallner. Trepi valem: Taavi Vallner. Insener: Marika Stokkeby. Projekt 2004, valmis 2005. Ill.: joonis, 7 värv. fotot

  3. Disainikaart : Hispaania / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2009-01-01

    Hispaania tuntumad arhitektid, disainerid, kunstnikud. Antoni Gaudí (1852-1926), Pablo Picasso (1881-1973), Félix Candela (1910-1997), Marti Guixe, Santiago Calatrava, Herme Ciscar, Monica Garcia, Roger Arquer, Patricia Urquiola, Jaime Hayón

  4. Chicago arhitektuuribiennaal / Eve Komp

    Index Scriptorium Estoniae

    Komp, Eve, 1982-

    2015-01-01

    Chicagos esimest korda korraldatud arhitektuuribiennaali nimi oli "The State of the Art of Architecture", mis toimus 03. oktoober 2015.a. - 03. jaanuar 2016.a. Biennaali eesmärk oli pakkuda rahvusvahelist arhitektuurisündmust kohalikule arhitektuurikogukonnale.

  5. A New Paradigm Hidden in Steganography

    Science.gov (United States)

    2000-01-01

    the n least signi cant bits ( LSB ) of each pixel in the cov- erimage, with the n most signi cant bits (MSB) from the corresponding pixel of the image to...e.g., 2 LSB are (0,0) ) to 3 (e.g., 2 LSB are (1,1) ), it is visually impossible for Eve to detect the steganography . Of course, if Eve has knowl...cryptographic security when the steganography has failed. Simply encrypt the embedded bits so that the 2 LSB in the stegoimage appear as white noise

  6. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  7. Dosimetry comparison of pelvimetry methods using conventional radiographs and CT

    International Nuclear Information System (INIS)

    Resten, A.; Suissa, M.; Musset, D.; Mausoleo, F.; Valero, M.; Taylor, S.

    2001-01-01

    To determine the fetal and maternal exposure to radiation by use of thermoluminescent dosimeters in order to compare conventional and CT-scan X-ray. Dosimetry was performed with an anthropomorph phantom. Thermoluminescent dosimeters were positioned on the surface and in the depth of the phantom. Digital radiography of the pelvis was performed according to a standard technique. CT-scan of the pelvis was performed according to the Buthiau's technique. With CT, the dose reached 0.31 to 4.95 mGy, with a dose of 2.32 mGy for the fetal gonads. With standard technique, the doses reached 0.03 to 0.39 mGy, with a dose of 0.39 mGy for the fetal gonads. With CT the fetus and the mother were exposed to 1/10. of the total dose delivered using conventional X-rays and the dose distribution was more homogeneous. (author)

  8. Radiation hormesis using an x-ray radiography device. The fourth report. Radiation hormesis of salad rocket

    International Nuclear Information System (INIS)

    Sakuma, Atsushi; Nakayama, Miho

    2006-01-01

    Radiation hormesis was studied for salad rocket plant (Eruca vesicaria sp.sativa), using different energies of X-ray (100 kV and 10 MV). To get the optimum dose for plant to provide the highest growth, the dose for the seeds was changed from 0 to 3000 mGy using 100 kV of X-ray. The highest growth of the plant was found for the dose of 600 mGy. When the seeds were irradiated to 600 mGy with 100 kV and 10 MV X-rays, in both cases, the growth of the irradiated seeds was higher than those without irradiation, where P-values were 0.0112 and 0.0214, respectively. In the case of 600 mGy irradiation, there was not any significant change in the plant growth between the seeds irradiated with 10 MV and 100 kV X-ray (P=0.862). (author)

  9. Occupational radiation exposure in the GDR in 1980

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,781 persons), measurements with a whole-body counter and analyses of biosamples (351 persons in all). According to the film data, the monthly exposures exceeding 4 mGy totalled 682 including 48 doses higher than 10 mGy. Four workers received annual doses above 50 mGy, with the highest value being 1410 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  10. Occupational radiation exposure in the GDR in 1979

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,178 persons), measurements with a whole-body counter (247 persons) and analyses of biosamples (318 persons). According to the film data, the monthly exposures exceeding 4 mGy totalled 610 including 92 doses higher than 10 mGy. Six workers received annual doses above 50 mGy, with the highest value being 123 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing the internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  11. Patient and staff dose during hysterosalpinography

    International Nuclear Information System (INIS)

    Buls, N.; Osteaux, M.

    2001-01-01

    Hysterosalpingography (HSG) is a useful and widely employed technique which uses X-ray fluoroscopy to investigate the female genital tract. Fluoroscopy is assessed by a gynaecologist, a physician who is not always trained to work with ionising radiation. Dose-area product measurements in a group of 34 patients allowed an estimation of the median effective dose (0,83 mSv) and the median dose to the ovaries (1,63 mGy) of the patient per procedure. The dose to the staff was estimated using thermoluminescent dosimetry. The following median entrance surface doses were estimated per procedure: 0,22 mGy to the lens of the eye, 0,15 mGy to the neck at thyroid level and 0,19 mGy to the back of the hand. The annual eye dose limit could be exceeded if the gynaecologist is a member of the public. (author)

  12. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Science.gov (United States)

    Sina, S; Zeinali, B; Karimipoorfard, M; Lotfalizadeh, F; Sadeghi, M; Zamani, E; Faghihi, R

    2014-01-01

    Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100. PMID:25599058

  13. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Directory of Open Access Journals (Sweden)

    Sina S

    2014-12-01

    Full Text Available Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti and GR-200 (LiF: Mg, Cu, P and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100.

  14. Performance degradation of ferrofluidic feedthroughs in a mixed irradiation field

    Science.gov (United States)

    Simos, Nikolaos; Fernandes, S.; Mittig, Wolfgang; Pellemoine, Frederique; Avilov, M.; Kostin, M.; Mausner, L.; Ronningen, R.; Schein, M.; Bollen, G.

    2017-01-01

    Ferrofluidic feedthrough (FF) rotary seals containing either NdFeB or SmCo-type permanent magnets have been considered for use in the target and beam dump systems of the Facility for Rare Isotope Beams (FRIB). To evaluate their performance under irradiation three FF seals were irradiated in a mixed field consisting of fast neutrons, protons and γ-rays to an average absorbed dose of 0.2, 2.0, and 20.0 MGy at the Brookhaven Linac Isotope Producer facility (BLIP). The radiation types and energy profiles mimic those expected at the FRIB facility. Degradation of the operational performance of these devices due to irradiation is expected to be the result of the de-magnetization of the permanent magnets contained within the seal and the changes in the ferrofluid properties. Post-irradiation performance was evaluated by determining the ferrofluidic seal vacuum tightness and torque under static and dynamic conditions. The study revealed that the ferrofluidic feedthrough seal irradiated to a dose of 0.2 MGy maintained its vacuum tightness under both static and rotational condition while the one irradiated to a dose of 2.0 MGy exhibited signs of ferrofluid damage but no overall performance loss. At 20 MGy dose the effects of irradiation on the ferrofluid properties (viscosity and particle agglomeration) were shown to be severe. Furthermore, limited de-magnetization of the annular shaped Nd2Fe14B and Sm2Co17 magnets located within the irradiated FFs was observed for doses of 0.2 MGy and 20 MGy respectively.

  15. The biological effects of exposure to ionising radiation

    International Nuclear Information System (INIS)

    Higson, D.J.

    2016-01-01

    Scenarios for exposure to ionising radiation range from natural background radiation (chronic) to the explosions of atomic bombs (acute), with some medical, industrial and research exposures lying between these extremes. Biological responses to radiation that predominate at high doses incurred at high dose rates are different from those that predominate at low doses and low dose rates. Single doses from bomb explosions ranged up to many thousand mGy. Acute doses greater than about 1000 mGy cause acute radiation syndrome (ARS). Below this threshold, radiation has a variety of potential latent health effects: Change to the incidence of cancer is the most usual subject of attention but change to longevity may be the best overall measure because decreased incidences of non-cancer mortality have been observed to coincide with increased incidence of cancer mortality. Acute doses greater than 500 mGy cause increased risks of cancer and decreased life expectancy. For doses less than 100 mGy, beneficial overall health effects ('radiation hormesis') have been observed. At the other end of the spectrum, chronic exposure to natural radiation has occurred throughout evolution and is necessary for the normal life and health of current species. Dose rates greater than the present global average of about 2 mGy per year have either no discernible health effect or beneficial health effects up to several hundred mGy per year. It is clearly not credible that a single health effects model -- such as the linear no-threshold (LNT) model of risk estimation -- could fit all latent health effects. A more realistic model is suggested.

  16. Assessment of Regional Pediatric Computed Tomography Dose Indices in Tamil Nadu.

    Science.gov (United States)

    Saravanakumar, A; Vaideki, K; Govindarajan, K N; Jayakumar, S; Devanand, B

    2017-01-01

    The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups: <1 year, and 1-5 years. CT dose indices were measured using a 10 cm 3 pencil ion chamber with pediatric head and body polymethyl methacrylate phantoms. Dose data such as volumetric CT dose index (CTDI v ) and dose length product (DLP) on a minimum of twenty average-sized pediatric patients in each category were recorded to calculate a mean site CTDI v and DLP value. The rounded 75 th percentile was used to calculate a pediatric DRL for each hospital, and then region by compiling all results. Data were collected for 3600 pediatric patients. Pediatric CT DRL for two age groups: <1 year (CTDI v and DLP of head [20 mGy, 352 mGy.cm], chest [7 mGy, 120 mGy.cm] and abdomen [12 mGy, 252 mGy.cm]), and 1-5 years (CTDI v and DLP of head [38 mGy, 505 mGy.cm], chest [8 mGy, 132 mGy.cm] and abdomen [14 mGy, 270 mGy.cm]) for select procedures have been calculated. Proposed pediatric DRLs of CTDI v and DLP for head procedure were lower, and for chest and abdomen procedures were higher than European pediatric DRLs for both age groups.

  17. Primary beam ionizing radiation for patients during coronary cineangiography

    International Nuclear Information System (INIS)

    Ramirez, Alfredo; Leyton, Fernando; Gamarra, Jorge; Oyarzun C, Carlos; Silva, Ana Maria; Ugalde, Hector; Dussaillant, Gaston

    2001-01-01

    Current cardiology practice incorporates hemodynamic and angiographic studies as normal procedures. Clinical actions have to be taken in interventionist cardiology that demand prolonged exposure times to radiation, which implies submitting patients to quantitatively significant doses. This work is a preliminary phase for clinical studies involving long procedures in hemodynamic and electrophysiological interventionist cardiology to show the magnitude of the radiation doses received by the patients after a proper diagnosis. The aim is to improve the patient's radiological protection as well as that of the staff involved. The study group consisted of 18 patients who underwent coronary angiography procedures with Siemens Angioskop D equipment and a Siemens Polidoros 80 generator. Four TLD Crystal detectors were used for the patient's dosimetry, which were located in the dorsal region along the left para scapular line, on the mid line of the thyroid region and a detector on the mid point between the umbilical zone and the pubis symphysis. For procedure times of 14±4.3 min., with fluoroscope times of 3.6±2.5 min., connection techniques of 87±15 kV. and 126±24 mA, the radiations recorded in the left inter scapular and right inter scapular regions were 215±199 mGy (1-710 mGy range) and 255±212 mGy ( 22 - 791mGy range ). The radiations in the pubic and thyroid regions were 0.23±0.07 mGy and 3.62±2.44 mGy, respectively (CO)

  18. SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

    International Nuclear Information System (INIS)

    Deshpande, S; Dhote, D; Kumar, R; Thakur, K

    2015-01-01

    Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens doses were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT

  19. Intracellular magnesium concentrations in dogs with gastric dilatation-volvulus.

    Science.gov (United States)

    Bebchuk, T N; Hauptman, J G; Braselton, W E; Walshaw, R

    2000-11-01

    To quantify and compare intracellular magnesium concentrations (Mgi) in clinically normal dogs (control dogs) and dogs that have gastric dilatation-volvulus (GDV dogs) and to determine whether there is a difference in Mgi and serum magnesium concentrations (Mgs) between GDV dogs with and without cardiac arrhythmias. 41 control dogs and 21 GDV dogs. Rectus abdominis muscle specimens were obtained from control and GDV dogs for determination of Mgi. Blood samples were obtained from GDV dogs for determination of Mgs, and dogs were monitored for 48 hours for cardiac arrhythmias. Muscle specimens were frozen at -40 C, oven dried at 95 C, and digested with concentrated nitric acid. Multielemental analyses were performed by simultaneous/sequential inductively coupled plasma-atomic emission spectroscopy with fixed-cross flow nebulization. The Mg, was standardized to sulfur content to correct for the amount of fat and fascia in the muscle specimen. Mean (+/- SEM) values were recorded in parts per million (ppm). Results-There were no significant differences in Mgi between control (627 +/- 11.1 ppm) and GDV (597 +/- 20.5 ppm) dogs, in Mgi between GDV dogs with (590 +/- 34 ppm) and without (584 +/- 29 ppm) cardiac arrhythmias, and in Mgs between GDV dogs with (1.77 +/- 0.26 ppm) and without (1.51 +/- 0.09 ppm) cardiac arrhythmias. There was no correlation between Mgs and Mgi (R2 = 0.0001). Results indicate that Mg depletion is not pathophysiologically important in dogs with GDV and does not play a role in the cardiac arrhythmias detected in these patients.

  20. Positron annihilation and thermally stimulated current of electron beam irradiated polyetheretherketone

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Shigetaka; Shinyama, Katsuyoshi; Baba, Makoto [Hachinohe Inst. of Tech., Hachinohe, Aomori (Japan); Suzuki, Takenori

    1997-03-01

    Positron lifetime measurements were applied to electron beam irradiated poly(ether-ether-ketone). The lifetime, {tau}{sub 3}, of the ortho-positronium of unirradiated and 5 MGy irradiated specimen became rapidly longer above about 150degC. {tau}{sub 3} of 50 MGy and 100 MGy irradiated specimen was shorter than that of unirradiated one. Thermally stimulated current (TSC) decreased with increasing the dose before voltage application. In the case of voltage application, a TSC peak appeared and the peak value decreased with increased the dose. The correlation between the results of positron annihilation and TSC was investigated. (author)

  1. Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Woussen, S.; Vanbeckevoort, D.; Bosmans, H.; Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Lopez-Rendon, X.; Zanca, F. [University Hospitals Leuven, Department of Imaging and Pathology, Leuven (Belgium)

    2016-04-15

    To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. (orig.)

  2. Environmental effects of radionuclides - observations on natural ecosystems

    International Nuclear Information System (INIS)

    Copplestone, D.; Toal, M.E.; Johnson, M.S.; Jackson, D.; Jones, S.R.

    2000-01-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137 Cs, 238 Pu, 239+240 Pu and 241 Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d -1 ) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10 -3 mGy d -1 , 2.2x10 -3 mGy d -1 and 1.0x10 -3 mGy d -1 respectively. The values are at least three orders of magnitude lower than the 1 mGy d -1 level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  3. Increased apoptosis and DNA double-strand breaks in the embryonic mouse brain in response to very low-dose X-rays but not 50 Hz magnetic fields.

    Science.gov (United States)

    Saha, Shreya; Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Ricket, Nicole; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2014-11-06

    The use of X-rays for medical diagnosis is enhancing exposure to low radiation doses. Exposure to extremely low-frequency electromagnetic or magnetic fields is also increasing. Epidemiological studies show consistent associations of childhood leukaemia with exposure to magnetic fields but any causal relationship is unclear. A limitation in assessing the consequence of such exposure is the availability of sensitive assays. The embryonic neuronal stem and progenitor cell compartments are radiosensitive tissues. Using sensitive assays, we report a statistically significant increase in DNA double-strand break (DSB) formation and apoptosis in the embryonic neuronal stem cell compartment following in utero exposure to 10-200 mGy X-rays. Both endpoints show a linear response. We also show that DSB repair is delayed following exposure to doses below 50 mGy compared with 100 mGy. Thus, we demonstrate in vivo consequences of low-dose radiation. In contrast to these impacts, we did not observe any significant induction of DSBs or apoptosis following exposure to 50 Hz magnetic fields (100 or 300 µT). We conclude that any DSB induction by treatment with magnetic fields is lower than following exposure to 10 mGy X-rays. For comparison, certain procedures involving computed tomography scanning are equivalent to 1-5 mGy X-rays.

  4. Environmental effects of radionuclides--observations on natural ecosystems.

    Science.gov (United States)

    Copplestone, D; Toal, M E; Johnson, M S; Jackson, D; Jones, S R

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137Cs, 238Pu, 239+240Pu and 241Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d(-1)) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0 x 10(-3) mGy d(-1), 2.2 x 10(-3) mGy d(-1) and 1.0 x 10(-3) mGy d(-1) respectively. The values are at least three orders of magnitude lower than the 1 mGy d(-1) level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed.

  5. Effects of Low Versus Moderate Glycemic Index Diets on Aerobic Capacity in Endurance Runners: Three-Week Randomized Controlled Crossover Trial

    Directory of Open Access Journals (Sweden)

    Krzysztof Durkalec-Michalski

    2018-03-01

    Full Text Available The glycemic index (GI of ingested carbohydrates may influence substrate oxidation during exercise and athletic performance. Therefore, the aim of this study was to assess the effect of low- and moderate-GI three-week diets on aerobic capacity and endurance performance in runners. We conducted a randomized crossover feeding study of matched diets differing only in GI (low vs. moderate in 21 endurance-trained runners. Each participant consumed both, low- (LGI and moderate-GI (MGI high-carbohydrate (~60% and nutrient-balanced diets for three weeks each. At the beginning and end of each diet, participants had their aerobic capacity and body composition measured and performed a 12-min running test. After LGI, time to exhaustion during incremental cycling test (ICT and distance covered in the 12-min run were significantly increased. The MGI diet led to an increase in maximal oxygen uptake ( V ˙ O2max, but no performance benefits were found after the MGI diet. The LGI and MGI diets improved time and workload at gas exchange threshold (GET during ICT. The results indicate that a three-week high-carbohydrate LGI diet resulted in a small but significant improvement in athletic performance in endurance runners. Observed increase in V ˙ O2max on MGI diet did not affect performance.

  6. CPAP Devices for Emergency Prehospital Use: A Bench Study.

    Science.gov (United States)

    Brusasco, Claudia; Corradi, Francesco; De Ferrari, Alessandra; Ball, Lorenzo; Kacmarek, Robert M; Pelosi, Paolo

    2015-12-01

    CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions. Copyright © 2015 by Daedalus Enterprises.

  7. Photon hormesis deactivates alpha-particle induced bystander effects between zebrafish embryos

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Cheng, S.H.; Yu, K.N.

    2017-01-01

    In the present work, we studied the effects of low-dose X-ray photons on the alpha-particle induced bystander effects between embryos of the zebrafish, Danio rerio. The effects on the naive whole embryos were studied through quantification of apoptotic signals (amounts of cells undergoing apoptosis) at 24 h post fertilization (hpf) using vital dye acridine orange staining, followed by counting the stained cells under a fluorescent microscope. We report data showing that embryos at 5 hpf subjected to a 4.4 mGy alpha-particle irradiation could release a stress signal into the medium, which could induce bystander effect in partnered naive embryos sharing the same medium. We also report that the bystander effect was deactivated when the irradiated embryos were subjected to a concomitant irradiation of 10 or 14 mGy of X-rays, but no such deactivation was achieved if the concomitant X-ray dose dropped to 2.5 or 5 mGy. In the present study, the significant drop in the amount of apoptotic signals on the embryos having received 4.4 mGy alpha particles together X-rays irradiation from 2.5 or 5 mGy to 10 or 14 mGy, together with the deactivation of RIBE with concomitant irradiation of 10 or 14 mGy of X-rays supported the participation of photon hormesis with an onset dose between 5 and 10 mGy, which might lead to removal of aberrant cells through early apoptosis or induction of high-fidelity DNA repair. As we found that photons and alpha particles could have opposite biological effects when these were simultaneously irradiated onto living organisms, these ionizing radiations could be viewed as two different environmental stressors, and the resultant effects could be regarded as multiple stressor effects. The present work presented the first study on a multiple stressor effect which occurred on bystander organisms. In other words, this was a non-targeted multiple stressor effect. The photon hormesis could also explain some failed attempts to observe neutron-induced bystander

  8. Ethylene evolution and endo-beta-mannanase activity during lettuce seed germination at high temperature Evolução de etileno e atividade da enzima endo-beta-mananase durante a germinação de sementes de alface sob altas temperaturas

    Directory of Open Access Journals (Sweden)

    Warley Marcos Nascimento

    2004-04-01

    Full Text Available High temperatures during lettuce seed imbibition can delay or completely inhibit germination and the endosperm layer appears to restrict the radicle protrusion. The role of endo-beta-mannanase during lettuce seed germination at 35°C and the influence of ethylene in endo-beta-mannanase regulation were investigated. Seeds of 'Dark Green Boston' (DGB and 'Everglades' (EVE were germinated in water, or 10 mmol L-1 of 1-aminocyclopropane-1-carboxylic acid (ACC, or 10 mmol L-1 of aminoethoxyvinylglycine (AVG, or 20 mmol L-1 of silver thiosulphate (STS. Seeds were also primed in polyethylene glycol (PEG, or PEG + ACC, PEG + AVG, or PEG + STS. Untreated seeds germinated 100% at 20°C. At 35°C, EVE seeds germinated 100%, whereas DGB seeds germinated only 33%. Seed priming or adding ACC during incubation increased germination at 35°C. Higher ethylene evolution was detected in EVE than in DGB during germination at 35°C. AVG did not inhibit seed germination of DGB at 35°C, but STS did. Higher endo-beta-mannanase activity was observed in EVE compared with DGB seeds. Providing ACC either during priming or during germination increased endo-beta-mannanase activity, whereas AVG and STS led to decreased or no activity. Ethylene may overcome the inhibitory effect of high temperature in thermosensitive lettuce seeds due to increased endo-beta-mannanase, possibly leading to weakening of the endosperm.Altas temperaturas durante a embebição das sementes de alface podem atrasar ou inibir a germinação e o endosperma parece ser o responsável na restrição da protrusão da radícula. O envolvimento da enzima endo-beta-mananase durante a germinação de sementes de alface a 35°C e a influência do etileno na regulagem desta enzima foram estudados. Sementes das cultivares Dark Green Boston (DGB e Everglades (EVE foram germinadas em água ou em soluções de 10 mmol L-1 de 1-aminociclopropano-1-ácido carboxilico (ACC, 10 mmol L-1 de amino-etoxi-vinil-glicina (AVG

  9. Radiation dose estimation by tooth enamel EPR dosimetry for residents of Dolon and Bodene

    International Nuclear Information System (INIS)

    Zhumadilov, Kassym; Ivannikov, Alexander; Apsalikov, Kazbek N.

    2006-01-01

    The method of electron paramagnetic resonance (EPR) dosimetry was applied to the enamel of the teeth extracted from the residents of the Dolon and Bodene settlements of the Beskaragay district, which is the area adjacent to the radioactive fallout of the most contaminating nuclear test of 1949. The individual accidental radiation doses due to the fallout were obtained from the amplitude of the radiation induced EPR signal from the CO 2- radical using the calibration method, after determining the parameters of EPR measurements to obtain the best reproducibility of the signal intensities. It was shown that after subtracting the natural background dose from the total absorbed dose obtained by EPR the residents of Dolon and Bodene received accidental radiation doses up to 356 mGy with an average value of 74.1 ± 45.5 mGy before 1949 while the younger population received up to about 100 mGy with an average value of 11.5 ± 37.7 mGy. (author)

  10. Level of patient and operator dose in the largest cardiac centre in Greece

    International Nuclear Information System (INIS)

    Tsapaki, V.; Patsilinakos, S.; Voudris, V.; Magginas, A.; Pavlidis, S.; Maounis, T.; Theodorakis, G.; Koutelou, M.; Vrantza, T.; Nearchou, M.; Nikolaki, N.; Kollaros, N.; Kyrozi, E.; Kottou, S.; Karaiskos, P.; Neofotistou, E.; Cokkinos, D.

    2008-01-01

    The objective of this study was to investigate the patient and staff doses in the most frequent interventional cardiology (IC) procedures performed in Onassio, the largest Cardiac Centre in Greece. Data were collected from three digital X-ray systems for 212 coronary angiographies, 203 percutaneous transluminal coronary angio-plasties (PTCA) and 134 various electrophysiological studies. Patient skin dose was measured using suitably calibrated slow radiotherapy films and cardiologist dose using suitably calibrated thermoluminescent dosemeters placed on left arm, hand and foot. Patient median dose area product (DAP) (all examinations) ranged between 6.7 and 83.5 Gy cm 2 . Patient median skin dose in PTCA was 799 mGy (320-1660 mGy) and in RF ablation 160 mGy (35-1920 mGy). Median arm, hand and foot dose to the cardiologist were 12.6, 27 and 13 μSv, respectively, per procedure. The great range of radiation doses received by both patients and operators confirms the need for continuous monitoring of all IC techniques. (authors)

  11. Level and distribution of the radiation dose to the population from a mammography screening programme in New Zealand

    Energy Technology Data Exchange (ETDEWEB)

    Bulling, S.M.; Nicoll, J.J. [Otago Univ., Dunedin (New Zealand). Dept. of Physics

    1995-12-31

    The Otago Southland Breast Screening Programme offers biennial mammography to 19,000 eligible women on the South Island of New Zealand. A Quality Assurance programme ensures that international performance standards are met, in particular the radiation dose for a mammogram of 5 cm CIRS-X phantom is 1.7 mGy and careful retake analysis undertaken. This however does not reveal the absorbed dose received by individuals, nor how this varies between individuals. Machine parameters and compressed breast thickness for each film were recorded for 310 women who attended one centre during the three months ending February 1993 and absorbed doses calculated using Monte Carlo data. The mean compressed breast thickness for the 310 women was 4.9 cm, doses received for individual films ranged from 0.7 to 8.5 mGy while patient total doses were in the range 4 to 29 mGy with 75% of women receiving a dose of 7.1 mGy or less. (Author).

  12. Dosimetry using Gafchromic XR-RV2 radiochromic films in interventional radiology

    International Nuclear Information System (INIS)

    Neocleous, A.; Yakoumakis, E.; Gialousis, G.; Dimitriadis, A.; Yakoumakis, N.; Georgiou, E.

    2011-01-01

    Patient dose measurements of local entrance dose to the skin have been carried out using radiochromic film (Gafchromic XR-RV2) in a sample of interventional procedures. The major aim of the work was to measure patient entrance dose from such examinations using Gafchromic XR-RV2. Forty-five various interventional procedures (including nephrostomies and urinary stenting, biliary stenting and percutaneous transhepatic biliary drainage (PTBD) and aorta stent grafting) were evaluated. Maximum entrance doses were 537±119 mGy in nephrostomies, 943±631 mGy in biliary stenting and PTBD and 2425±569 mGy in aorta stent grafting. Results indicate that all patients undergoing aorta stent grafting received skin dose above 1500 mGy, which means that there is an increasing potential to suffer radiation-induced skin injuries. The film provides dose mapping, the position of the skin area with highest dose and can be used for immediate qualitative and as well as for quantitative assessment of patient skin dose. (authors)

  13. The long-term effects of acute exposure to ionising radiation on survival and fertility in Daphnia magna

    International Nuclear Information System (INIS)

    Sarapultseva, Elena I.; Dubrova, Yuri E.

    2016-01-01

    The results of recent studies have provided strong evidence for the transgenerational effects of parental exposure to ionising radiation and chemical mutagens. However, the transgenerational effects of parental exposure on survival and fertility remain poorly understood. To establish whether parental irradiation can affect the survival and fertility of directly exposed organisms and their offspring, crustacean Daphnia magna were given 10, 100, 1000 and 10,000 mGy of acute γ-rays. Exposure to 1000 and 10,000 mGy significantly compromised the viability of irradiated Daphnia and their first-generation progeny, but did not affect the second-generation progeny. The fertility of F 0 and F 1 Daphnia gradually declined with the dose of parental exposure and significantly decreased at dose of 100 mGy and at higher doses. The effects of parental irradiation on the number of broods were only observed among the F 0 Daphnia exposed to 1000 and 10,000 mGy, whereas the brood size was equally affected in the two consecutive generations. In contrast, the F 2 total fertility was compromised only among progeny of parents that received the highest dose of 10,000 mGy. We propose that the decreased fertility observed among the F 2 progeny of parents exposed to 10,000 mGy is attributed to transgenerational effects of parental irradiation. Our results also indicate a substantial recovery of the F 2 progeny of irradiated F 0 Daphnia exposed to the lower doses of acute γ-rays. - Highlights: • Viability of irradiated daphnids and their F 1 progeny is compromised. • Viability of the F 2 progeny of irradiated parents is not affected. • Total fertility of irradiated daphnids and their F 1 progeny declines with the dose. • Total fertility of the F 2 progeny of parents exposed to 10,000 mGy is compromised. • The decreased fertility among the F 2 progeny is transgenerational phenomenon.

  14. The long-term effects of acute exposure to ionising radiation on survival and fertility in Daphnia magna

    Energy Technology Data Exchange (ETDEWEB)

    Sarapultseva, Elena I. [Department of Biology, Institute of Nuclear Power Engineering NRNU MEPhI, Studgorodok,1, Obninsk, Kaluga Region 249040 (Russian Federation); National Research Nuclear University “MEPhI”, Kashirskoe Highway, 31, Moscow 115409 (Russian Federation); Dubrova, Yuri E., E-mail: yed2@le.ac.uk [Department of Genetics, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Vavilov Institute of General Genetics, Russian Academy of Sciences, Gubkina Str. 3, 11933 Moscow (Russian Federation)

    2016-10-15

    The results of recent studies have provided strong evidence for the transgenerational effects of parental exposure to ionising radiation and chemical mutagens. However, the transgenerational effects of parental exposure on survival and fertility remain poorly understood. To establish whether parental irradiation can affect the survival and fertility of directly exposed organisms and their offspring, crustacean Daphnia magna were given 10, 100, 1000 and 10,000 mGy of acute γ-rays. Exposure to 1000 and 10,000 mGy significantly compromised the viability of irradiated Daphnia and their first-generation progeny, but did not affect the second-generation progeny. The fertility of F{sub 0} and F{sub 1}Daphnia gradually declined with the dose of parental exposure and significantly decreased at dose of 100 mGy and at higher doses. The effects of parental irradiation on the number of broods were only observed among the F{sub 0}Daphnia exposed to 1000 and 10,000 mGy, whereas the brood size was equally affected in the two consecutive generations. In contrast, the F{sub 2} total fertility was compromised only among progeny of parents that received the highest dose of 10,000 mGy. We propose that the decreased fertility observed among the F{sub 2} progeny of parents exposed to 10,000 mGy is attributed to transgenerational effects of parental irradiation. Our results also indicate a substantial recovery of the F{sub 2} progeny of irradiated F{sub 0}Daphnia exposed to the lower doses of acute γ-rays. - Highlights: • Viability of irradiated daphnids and their F{sub 1} progeny is compromised. • Viability of the F{sub 2} progeny of irradiated parents is not affected. • Total fertility of irradiated daphnids and their F{sub 1} progeny declines with the dose. • Total fertility of the F{sub 2} progeny of parents exposed to 10,000 mGy is compromised. • The decreased fertility among the F{sub 2} progeny is transgenerational phenomenon.

  15. Zippo Marx

    Directory of Open Access Journals (Sweden)

    Robin Aaron Bright

    2017-09-01

    Full Text Available Goddesses, like Norse Hel, signify love for women, and between women, because `woman`s seed` is the `seed` of Eve represented by Jesus, who was tortured to death by the Romans as a `dissident` Jewish rabbi nailed to a cross of wood on the hill of Calvary outside the city of Jerusalem in occupied Palestine and left there until he died. Jesus` Resurrection and Ascension to heaven thereafter prefigured that of `woman`s seed`, which is why his mother, the Virgin Mary, approaches to the role of goddess in Christianity, because women who`re loved appear to be worshipped as goddesses by those who don`t love women. So God specifically punishes Eve and Adam for accepting that they`ll be `as gods`, because Eve is Adam`s `goddess`, who he`s to love in order to be redeemed through `woman`s seed`, and the birth of human brainpower to liberate the species from host womb slavery in parasitism, which wants ephemerality for humans in order to keep them as slaves without labor saving technologies conferring freedom.

  16. Pediatric CT dose reduction for suspected appendicitis: a practice quality improvement project using artificial Gaussian noise--part 1, computer simulations.

    Science.gov (United States)

    Callahan, Michael J; Kleinman, Patricia L; Strauss, Keith J; Bandos, Andriy; Taylor, George A; Tsai, Andy; Kleinman, Paul K

    2015-01-01

    The purpose of this study was to develop a departmental practice quality improvement project to systematically reduce CT doses for the evaluation of suspected pediatric appendicitis by introducing computer-generated gaussian noise. Two hundred MDCT abdominopelvic examinations of patients younger than 20 years performed with girth-based scanning parameters for suspected appendicitis were reviewed. Two judges selected 45 examinations in which the diagnosis of appendicitis was excluded (14, appendix not visualized; 31, normal appendix visualized). Gaussian noise was introduced into axial image series, creating five additional series acquired at 25-76% of the original dose. Two readers reviewed 270 image series for appendix visualization (4-point Likert scale and arrow localization). Volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) were calculated by use of patient girth. Confidence ratings and localization accuracy were analyzed with mixed models and nonparametric bootstrap analysis at a 0.05 significance level. The mean baseline SSDE for the 45 patients was 16 mGy (95% CI, 12-20 mGy), and the corresponding CTDIvol was 10 mGy (95% CI, 4-16 mGy). Changes in correct appendix localization frequencies were minor. There was no substantial trend with decreasing simulated dose level (p = 0.46). Confidence ratings decreased with increasing dose reduction (p = 0.007). The average decreases were -0.27 for the 25% simulated dose (p = 0.01), -0.17 for 33% (p = 0.03), and -0.03 for 43% (p = 0.65). Pediatric abdominal MDCT can be performed with 43% of the original dose (SSDE, 7 mGy; CTDIvol, 4.3 mGy) without substantially affecting visualization of a normal appendix.

  17. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  18. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  19. Optimization of the Radiological Protection of Patients in Diagnostic Radiology Department at Kenyatta National Hospital in Kenya

    International Nuclear Information System (INIS)

    Korir, G.K.; Ochieng, B.O.M; Wambani, J. S.

    2008-01-01

    The use of ionizing radiation in the medical field accounts for the largest contribution of radiation exposure to man. Use of ionizing radiation requires a careful balance of risks and benefits due to the somatic and hereditary which are well known to have no threshold level due to the random nature of radiation. The radiation doses received by patients undergoing radiographic examinations were measured in 189 randomly selected patients from three different x-ray rooms at a referral, teaching and research hospital in Kenya. The exercise was done on 54 pediatric and 135 adult patients during the screening period between October and November 2005. The entrance surface dose (ESD) to the patients undergoing each of these procedures was measured using LiF-100 thermoluminescent dosimeters (TLDs). The values obtained ranged from 0.33 mGy to 143 mGy for adult patients and 0.12 mGy to 4.32 mGy for pediatric patients. The mean values were found to be 8.44 mGy, 11.16 mGy and 1.44 mGy for rooms A, B and C respectively. The hospital's average dose stood at 7.01 mGy. The mean patient thickness for adults in cm were 19.5 for chest PA/AP, 28 chest LAT, 27 lumbar sacral, 28 lumbar spine AP, 30 lumbar spine LAT and for children 9.5 chest AP, 19.5 chest LAT, 8 post nasal space (PNS) 11.5 lumbar spine AP and 15 for lumbar spine LAT. Adult ages averaged at 35 years and less than 15 years old for sensitive to gamma rathe ESD in most procedures in adults were found to exceed the International ESD reference levels. However, it should be noted that so far guidance levels (GL) for children do not exist. The x-ray units were tested for quality control performance. They failed with respect to kVp accuracy, focal spot size and total filtration tests. From the Radiologists image quality assessment of the radiographs, 52% were awarded grade A, 40% grade B and 8% grade C. Film rejection analysis was measured to be 14% in overall. The following were the major causes; positioning, underexposure and

  20. Eesti parim robottantsija : breik on mind hullemast päästnud / Kristel Kirss

    Index Scriptorium Estoniae

    Kirss, Kristel, 1967-

    2003-01-01

    Breiktantsu festivali Battle of the East 2003 Balti alavoorus electric boogies teiseks jäänud breikar Joel Juht endast ja breiktantsust. Lisa : sõnum "Tants, mitte sportvõimlemine" ja "Breiktantsu "Battle of the Year 2003" Balti alavooru võitjad

  1. Long-Term Musical Group Interaction Has a Positive Influence on Empathy in Children

    Science.gov (United States)

    Rabinowitch, Tal-Chen; Cross, Ian; Burnard, Pamela

    2013-01-01

    Musical group interaction (MGI) is a complex social setting requiring certain cognitive skills that may also elicit shared psychological states. We argue that many MGI-specific features may also be important for emotional empathy, the ability to experience another person's emotional state. We thus hypothesized that long-term repeated participation…

  2. A New Quantum Secure Direct Communication Scheme with Authentication

    International Nuclear Information System (INIS)

    Dan, Liu; Chang-Xing, Pei; Dong-Xiao, Quan; Nan, Zhao

    2010-01-01

    A new quantum secure direct communication (QSDC) scheme with authentication is proposed based on polarized photons and EPR pairs. EPR pairs are used to transmit information, while polarized photons are used to detect Eve and their encoding bases are used to transmit authentication information. Alice and Bob have their own identity number which is shared by legal users only. The identity number is encoded on the bases of polarized photons and distilled if there is no Eve. Compared with other QSDC schemes with authentication, this new scheme is considerably easier and less expensive to implement in a practical setting

  3. Upconversion-based receivers for quantum hacking-resistant quantum key distribution

    Science.gov (United States)

    Jain, Nitin; Kanter, Gregory S.

    2016-07-01

    We propose a novel upconversion (sum frequency generation)-based quantum-optical system design that can be employed as a receiver (Bob) in practical quantum key distribution systems. The pump governing the upconversion process is produced and utilized inside the physical receiver, making its access or control unrealistic for an external adversary (Eve). This pump facilitates several properties which permit Bob to define and control the modes that can participate in the quantum measurement. Furthermore, by manipulating and monitoring the characteristics of the pump pulses, Bob can detect a wide range of quantum hacking attacks launched by Eve.

  4. Radiation induced micrencephaly in guinea pigs

    International Nuclear Information System (INIS)

    Wagner, L.K.; Johnston, D.A.; Felleman, D.J.

    1991-01-01

    A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays at doses of 75-mGy during this late embryonic stage of development is consistent with the findings of small head size induced in those exposed prior to the eight week of conception at Hiroshima. This implies a mechanism for micrencephaly different from those previously suggested and lends credence to a causal relation between radiation and small head size in humans at low doses as reported by Miller and Mulvihill. 16 refs., 13 tabs

  5. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  6. Patient dosimetry study of a paediatric CT examination

    International Nuclear Information System (INIS)

    Hranitzky, C.; Stadtmann, H.

    2011-01-01

    Dosimetry studies are of increasing interest in diagnostic high-dose applications such as computed tomography especially for examinations of children. A routine CT scan protocol for paediatric head and neck imaging was investigated at a new multi-detector CT scanner using LiF:Mg,Cu,P thermoluminescence dosemeters (TLDs) and a 0.125 cm 3 thimble ionization chamber. Calibrations of the detectors in terms of absorbed dose to water were carried out at the Dosimetry Laboratory Seibersdorf in standard radiation fields. The dosimetry method was validated in the spiral CT X-ray field by comparing TLD and ionization chamber measurement results in cylindrical PMMA phantoms. Absorbed dose results were within stated uncertainties. An anthropomorphic phantom representing a child of about 5 years was loaded with TLD chips at various organ and tissue positions in the head and neck region as well as at some critical organ locations. Organ dose values were calculated from TLD based average absorbed dose with about 5% total uncertainty, e.g. 22 mGy (eyes), 21 mGy (thyroid), 19 mGy (brain), 3.4 mGy (thymus), and 0.03 mGy (testes). For comparison purposes an effective dose of 1.9 mSv was estimated for the investigated paediatric CT examination based on ICRP-103 age-independent tissue-weighting factors.

  7. Environmental effects of radionuclides - observations on natural ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Copplestone, D. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom). E-mail: copplest at liv.ac.uk; Toal, M.E.; Johnson, M.S. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom); Jackson, D.; Jones, S.R. [Westlakes Scientific Consulting, Princess Royal Building, Westlakes Science and Technology Park, Moor Row, Cumbria CA24 3LN (United Kingdom)

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides {sup 137}Cs, {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d{sup -1}) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10{sup -3} mGy d{sup -1}, 2.2x10{sup -3} mGy d{sup -1} and 1.0x10{sup -3} mGy d{sup -1} respectively. The values are at least three orders of magnitude lower than the 1 mGy d{sup -1} level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  8. Increased apoptosis and DNA double-strand breaks in the embryonic mouse brain in response to very low-dose X-rays but not 50 Hz magnetic fields

    Science.gov (United States)

    Saha, Shreya; Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Ricket, Nicole; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2014-01-01

    The use of X-rays for medical diagnosis is enhancing exposure to low radiation doses. Exposure to extremely low-frequency electromagnetic or magnetic fields is also increasing. Epidemiological studies show consistent associations of childhood leukaemia with exposure to magnetic fields but any causal relationship is unclear. A limitation in assessing the consequence of such exposure is the availability of sensitive assays. The embryonic neuronal stem and progenitor cell compartments are radiosensitive tissues. Using sensitive assays, we report a statistically significant increase in DNA double-strand break (DSB) formation and apoptosis in the embryonic neuronal stem cell compartment following in utero exposure to 10–200 mGy X-rays. Both endpoints show a linear response. We also show that DSB repair is delayed following exposure to doses below 50 mGy compared with 100 mGy. Thus, we demonstrate in vivo consequences of low-dose radiation. In contrast to these impacts, we did not observe any significant induction of DSBs or apoptosis following exposure to 50 Hz magnetic fields (100 or 300 µT). We conclude that any DSB induction by treatment with magnetic fields is lower than following exposure to 10 mGy X-rays. For comparison, certain procedures involving computed tomography scanning are equivalent to 1–5 mGy X-rays. PMID:25209403

  9. Penelitian Nilai Beban Pencemaran Pada Beberapa Ekstrak Zat Warna Alam

    Directory of Open Access Journals (Sweden)

    Kun Lestari

    2016-04-01

    Full Text Available Zat Pewarna Alam (ZWA akan direkomendasikan sebagai pewarna yang ramah baik bagi lingkungan maupun kesehatan, disebabkan karena kandungan komponen alaminya mempunyai nilai beban pencemaran yang rendah, mudah terdegradasi secara biologis dan tidak beracun. Pernyataan tersebut perlu diyakinkan kebenarannya. Telah dilakukan pengujian terhadap ekstrak pekat (0,75-1,00° Be dari 13 jenis sumber ZWA dari beberapa daerah di Indonesia yaitu: bakau, secang. sonokeling. bayam, markisa. bengkirai, nangka, pinus, kruing, kara benguk, tingi, tegeran dan mengkudu. Bahan pencemaran dinyatakan terhadap nilai BOD5, COD dan kandungan Fe (besi dalam ekstrak pekat yang telah tersimpan selama ±12 bulan. Dari hasil pengujian terlihat bahwa kadar BOD5 dan COD dari 13 jenis ekstrak ZWA mempunyai nilai 1700 mg/l. Tujuh jenis ekstrak ZWA yaitu ekstrak dari kayu nangka, kayu pinus. kayu kruing, kulit kara benguk, kulit kayu tingi, kayu tegeran dan akar mengkudu mempunyai nilai BOD5 dan COD 1000 mg/l, sedangkan ekstrak kulit batang bakau, kayu secang, kayu sonokeling, kayu buyam, kulit buah markisa dan kayu bengkirai mempunyai nilai BOD5 dan COD antara 1100 - 1700 mg/I. Dibandingkan dengan beban pencemaran yang diakibatkan oleh limbah cair pada pencelupan batik menggunakan zat warna sintetis (ZWS seperti Indigosol yang mempunyai nilai BOD5 = 3.053 mg/I, COD = 10.230 mg/I, dan Naphtol yang mempunyai nilai BOD5 = 5.411 mg/I, COD= 19.921 mg/I maka beban pencemaran ekstrak pekat ZWA masih jauh lebih kecil. Melihat perbandingan COD/BOD5 (=1,3-1,6, beban pencemaran ekstrak pekat ZWA dapat dikelompokkan ke dalam golongan air limbah rumah tangga (COD/BOD5 (2.Zat Pewarna Alam (ZWA akan direkomendasikan sebagai pewarna yang ramah baik bagi lingkungan maupun kesehatan, disebabkan karena kandungan komponen alaminya mempunyai nilai beban pencemaran yang rendah, mudah terdegradasi secara biologis dan tidak beracun. Pernyataan tersebut perlu diyakinkan kebenarannya. Telah dilakukan

  10. SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Quails, N; Carranza, C; Correa, N; Bidari, S; Bickelhaup, M; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

  11. Neuroimmune response and sleep studies after whole body irradiation with high-LET particles

    Science.gov (United States)

    Marquette, C.; Mathieu, J.; Bertho, J.-M.; Galonnier, M.; Wysoki, J.; Maubert, C.; Balanzat, E.; Gerbin, R.; Aigueperse, J.; Clarençon, D.

    2009-10-01

    In order to investigate the biological effects of galactic rays on astronaut cerebral functions after space flight, mice were exposed to different heavy ions (HZE) in whole-body conditions at doses comparable to the galactic flux: 12C, 16O and 20Ne (95 MeV/u, at 42-76 mGy). Animals were also exposed to 42 mGy of 60Co radiation for comparison with HZE. The neuroimmune response, evaluated by interleukin-1 (IL-1) measurement, showed that this cytokine was produced 3 h after irradiation by 16O or 60Co. In contrast, neither 12C (56.7 mGy) nor 20Ne (76 mGy) induced IL-1 production. However, immunohistochemical staining of 12C-irradiated mouse brain tissue showed 2 months later a marked inflammatory reaction in the hippocampus and a diffuse response in parenchyma. Sleep studies were realized before and after exposure to 42 mGy of 16O and 76 mGy of 20Ne: only the 20Ne radiation displayed a small effect. A slight decrease in paradoxical sleep, corresponding to a reduction in the number of episodes of paradoxical sleep, was manifested between 8 and 22 days after exposure. Exposure to 12C and 16O induced no changes either in cellularity of spleen or thymus, or in caspase 3 activity (as much as four months after irradiation). Taken together, these data indicate that the CNS could be sensitive to heavy ions and that responses to HZE impact depend on the nature of the particle, the dose threshold and the time delay to develop biological processes. Differences in responses to different HZE highlight the complex biological phenomena to which astronauts are submitted during space flight.

  12. Neuro-immune response and sleep studies after whole body irradiation with high-LET particles

    International Nuclear Information System (INIS)

    Marquette, C.; Bertho, J.M.; Wysoki, J.; Maubert, C.; Gerbin, R.; Aigueperse, J.; Mathieu, J.; Galonnier, M.; Clarencon, D.; Balanzat, E.

    2009-01-01

    In order to investigate the biological effects of galactic rays on astronaut cerebral functions after space flight, mice were exposed to different heavy ions (HZE) in whole-body conditions at doses comparable to the galactic flux: 12 C, 16 O and 20 Ne (95 MeV/u, at 42-76 mGy). Animals were also exposed to 42 mGy of 60 Co radiation for comparison with HZE. The neuro-immune response, evaluated by interleukin-I (IL-1) measurement, showed that this cytokine was produced 3 h after irradiation by 16 O or 60 Co. In contrast, neither 12 C (56.7 mGy) nor 20 Ne (76 mGy) induced IL-1 production. However, immunohistochemical staining of 12 C-irradiated mouse brain tissue showed 2 months later a marked inflammatory reaction in the hippocampus and a diffuse response in parenchyma. Sleep studies were realized before and after exposure to 42 mGy of 16 O and 76 mGy of 20 Ne: only the 20 Ne radiation displayed a small effect. A slight decrease in paradoxical sleep, corresponding to a reduction in the number of episodes of paradoxical sleep, was manifested between 8 and 22 days after exposure. Exposure to 12 C and 16 O induced no changes either in cellularity of spleen or thymus, or in caspase 3 activity (as much as four months after irradiation). Taken together, these data indicate that the CNS could be sensitive to heavy ions and that responses to HZE impact depend on the nature of the particle, the dose threshold and the time delay to develop biological processes. Differences in responses to different HZE highlight the complex biological phenomena to which astronauts are submitted during space flight. (authors)

  13. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M [Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  14. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities

  15. Assessment of mean glandular dose to patients from digital mammography systems

    International Nuclear Information System (INIS)

    Pwamang, Caroline K.

    2016-07-01

    Mean glandular dose assessment of patients undergoing digital mammography examination has been done. A total of 297 patient data was used for the study. Basic Quality Control tests were done to ascertain the performance of the equipment used. The results of Quality Control tests indicated that the three Mammography units used for this study were functioning within the internationally acceptable performance criteria. Patients with a breast thickness of 30 mm within the two age groups of 40-49 yrs and 50-64 yrs received doses slightly higher than the acceptable dose levels. A patient in the category 40-49 yrs with breast thickness of 30 mm received 1.83 mGy as calculated Mean Glandular Dose, 2.10 mGy was the recorded dose and 1.58 mGy was recorded under the age group 50-64 yrs. These values have deviated by -22%, -40%, and -5.33% respectively from 1.5 mGy which is the recommended dose for a breast thickness of 30 mm. Also patients with breast thickness of 70 mm under the age group 40–49 yrs had a recorded dose of 6.58 mGy, which deviated by -1.21% from the recommended value of 6.5 mGy for that breast thickness. Aside these values, all the other values were within the recommended dose values. The percentage deviation between the recommended values and the calculated values was within ±25% which was a working limit that was set for this work. Doses delivered by the Full-field Digital mammography equipment were higher than doses delivered by the Computered Radiography equipment. The calculated Mean Glandular Doses for the three facilities were within recommended dose values. (author)

  16. Use of the EC quality criteria as a common method of inspecting CT laboratories - A pilot project by the Nordic radiation protection authorities

    International Nuclear Information System (INIS)

    Torp, C.G.; Olerud, H.M.; Einarsson, G.; Groen, P.; Leitz, W.; Servomaa, A.

    2001-01-01

    In the frame of Nordic radiation protection co-operation, quality criteria for computed tomography (CT) as published by the European Commission were used for the evaluation of selected CT laboratories in each of the Nordic countries. The mean values for all five countries of the weighted CT dose index (CTDI w ) and dose length product (DLP) were 60 mGy and 740 mGy · cm for CT of the brain, 11 mGy and 420 mGy · cm for CT of the chest, and 40 mGy and 420 mGy · cm for CT of the lumbar spine, respectively. A comparison with the reference levels set in the above mentioned publication gives a diversified result: compliance for the DLP-values is generally achieved with good margins whereas the CTDI w -values were frequently larger for brain and lumbar spine examinations. The radiographic technique was generally also within the recommendations from the EC. Generally most of the image quality criteria were fulfilled, but it must be borne in mind that the study was biased in the way that two local radiologists in consensus evaluated their own images. Image material from only three patients was selected for each of the clinical indications, that means the project was not designed for ranking laboratories, but it is a way of making the departments aware of the need for optimisation regarding image quality and patient dose, and also of the problems associated with this task. During the study suggestions were brought forward concerning amendments of the quality criteria: some need a better definition, some are not relevant for the diagnostic task in question, some could be added. Instead of 'yes' and 'no', a range of maybe 5 levels of visualisation should be introduced in order to better characterize the level of diagnostic performance. (author)

  17. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Survey of pediatric MDCT radiation dose from university hospitals in Thailand. A preliminary for national dose survey

    Energy Technology Data Exchange (ETDEWEB)

    Kritsaneepaiboon, Supika [Dept. of Radiology, Faculty of Medicine, Prince of Songkla Univ., Hat Yai (Thailand)], e-mail: supikak@yahoo.com; Trinavarat, Panruethai [Dept. of Radiology, Faculty of Medicine, Chulalongkorn Univ., Bangkok (Thailand); Visrutaratna, Pannee [Dept. of Radiology, Faculty of Medicine, Chiang Mai Univ., Chiang Mai (Thailand)

    2012-09-15

    Background: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation. Purpose: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP). Material and Methods: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDIvol) and DLP were recorded, categorized into four age groups: <1 year, 1- < 5 years, 5- <10 years, and 10- <15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results: Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDIvol: 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm. Conclusion: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDIvol and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

  19. Measurement of photo-neutron cross sections and isomeric yield ratios in the {sup 89}Y(γ,xn){sup 89-x}Y reactions at the bremsstrahlung end-point energies of 65, 70 and 75 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tatari, Mansoureh [Yazd Univ. (Iran, Islamic Republic of). Physics Dept.; Naik, Haladhara [Bhabha Atomic Research Centre, Mumbai (India). Radiochemistry Div.; Kim, Guinyun; Kim, Kwangsoo [Kyungpook National Univ., Daegu (Korea, Republic of). Dept. of Physics; Shin, Sung-Gyun; Cho, Moo-Hyun [Pohang Univ. of Science and Technology (Korea, Republic of). Div. of Advanced Nuclear Engineering

    2017-07-01

    The flux-weighted average cross sections of the {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reactions and the isomeric yield ratios of the {sup 87m,g}Y, {sup 86m,g}Y, and {sup 85m,g}Y radionuclides produced in these reactions with the bremsstrahlung end-point energies of 65, 70 and 75 MeV have been determined by an activation and off-line γ-ray spectrometric technique using the 100 MeV electron linac in Pohang Accelerator Laboratory, Korea. The theoretical {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reaction cross sections for mono-energetic photons have been calculated using the computer code TALYS 1.6. Then the flux-weighted theoretical values were obtained to compare with the present data. The flux-weighted experimental and theoretical {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reaction cross sections increase very fast from the threshold values to a certain bremsstrahlung energy, where the other reaction channels open up. Thereafter it remains constant a while and then slowly decreases with the increase of cross sections for other reactions. Similarly, the isomeric yield ratios of {sup 87m,g}Y, {sup 86m,g}Y and {sup 85m,g}Y in the {sup 89}Y(γ,xn; x=2-4){sup 89-x}Y reactions from the present work and literature data show an increasing trend from their respective threshold values to a certain bremsstrahlung energy. After a certain point of energy, the isomeric yield ratios increase slowly with the bremsstrahlung energy. These observations indicate the role of excitation energy and its partitioning in different reaction channels.

  20. Image evaluation and exposure dose with the application of tube voltage and adaptive statistical iterative reconstruction of low dose computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Joon [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Kim, Ki Jeong [Dept. of Radiology, Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Hye Nam [Dept. of Radiology, Gimsangyeong Internal Medicine Clinic, Nonsan (Korea, Republic of)

    2017-06-15

    The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were 103.21 mGy‧cm with no-ASIR and 85.94 mGy‧cm with 20%-ASIR, decreased by 17.27mGy‧cm (about 16.7%), and the values with 100 kVp were 63.84 mGy‧cm with no-ASIR and 53.25 mGy‧cm with 20%-ASIR, a decrease by 10.62 mGy‧cm ( about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

  1. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  2. SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

    International Nuclear Information System (INIS)

    Lipnharski, I; Quails, N; Carranza, C; Correa, N; Bidari, S; Bickelhaup, M; Rill, L; Arreola, M

    2016-01-01

    Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

  3. Image evaluation and exposure dose with the application of tube voltage and adaptive statistical iterative reconstruction of low dose computed tomography

    International Nuclear Information System (INIS)

    Moon, Tae Joon; Kim, Ki Jeong; Lee, Hye Nam

    2017-01-01

    The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were 103.21 mGy‧cm with no-ASIR and 85.94 mGy‧cm with 20%-ASIR, decreased by 17.27mGy‧cm (about 16.7%), and the values with 100 kVp were 63.84 mGy‧cm with no-ASIR and 53.25 mGy‧cm with 20%-ASIR, a decrease by 10.62 mGy‧cm ( about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise

  4. Survey of image quality and patient dose for computed tomography

    International Nuclear Information System (INIS)

    Augusto, Fernando Mecca

    2009-01-01

    The aim of this work is to evaluate the dose index and the image quality in seventeen computed tomography scanners installed in radiology departments at the city of Rio de Janeiro. The American College of Radiology (ACR) accreditation phantom (Gammex, 464) was used for the image quality evaluation. The following parameters were investigated according to the procedure manual of the ACR phantom: CT number calibration, exactitude of the slice thickness, low and high contrast resolution, uniformity, noise and artifacts. Despite of the CT number accuracy, only one scanner passed in the test. The low contrast resolution and the uniformity criteria were not accomplished in two different scanners. The conformity for the criteria established for slice width and high contrast was not verified in 16% and 11 % of the equipment respectively. The noise, expressed as a standard deviation measured in the center of the image in an adult abdomen protocol, ranged from 2.8 to 9.5. The ACR criteria of the accreditation program were not accomplished in the sample evaluated. Some parameters failed are essential to assure the diagnostic accuracy. For the head scans CTDI 100,VOL values varied between 9 and 109 mGy and the DLP from 160 to 2000 mGy cm for adults. Values for abdomen scans varied between 8 and 94 mGy and the DLP from 180 to 3700 mGy cm for adults, and CTDI 100,VOL from 3 to 54 mGy and DLP from 46 to 1300 mGy cm for children. Similar ranges were found for hi-resolution chest scans. These results are compatibles with those from reported literature and indicate a large potential for optimization and dose reduction, specially in pediatric patients. (author)

  5. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  6. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  7. Mutational influences of low-dose and high let ionizing radiation in drosophila melanogaster

    Science.gov (United States)

    Lei, Huang; Fanjun, Kong; Sun, Yeqing

    For cosmic environment consists of a varying kinds of radiation particles including high Z and energy ions which was charactered with low-dose and high RBE, it is important to determine the possible biofuctions of high LET radiation on human beings. To analyse the possible effectes of mutational influences of low-dose and high-LET ionizing radiation, wild fruit flies drosophila melanogaster were irradiated by 12C6+ ions in two LET levels (63.3 and 30 keV/µum) with different low doses from 2mGy to 2000mGy (2, 20, 200, 2000mGy) in HIRFL (Heavy ion radiation facility laboratory, lanzhou, China).In the same LET value group, the average polymorphic frequency was elevated along with adding doses of irradation, the frequency in 2000 mGy dose samples was significantly higher than other samples (p<0.01).These results suggest that genomic DNA sequence could be effected by low-dose and high-LET ionizing radiation, the irradiation dose is an important element in genomic mutation frequency origination.

  8. Dosimetry of beta particles using Li:Mg, Cu, P + Ptfe

    International Nuclear Information System (INIS)

    Olvera, L.; Azorin, J.; Rivera, T.

    2003-01-01

    This paper presents the experimental results of determining the thermoluminescence (Tl) response of LiF: Mg, Cu, P + Ptfe pellets excited with 90 Sr/ 90 Y beta radiation. The glow curve exhibited three peaks which appear at 121 C, 178 C and 217 C . Its relative sensitivity is 49 with respect to that of the TLD-100 dosemeter taken as a reference. The minimal dose that could be measured was 750 mGy. The Tl response as a function of dose was linear in the range of 0.7 mGy to 22.5 mGy. The study of the repeatability of the information contained in the pellets showed a standard deviation of 2 %. (Author)

  9. Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth shield

    International Nuclear Information System (INIS)

    Lai, C.W.K.; Chan, T.P.; Cheung, H.Y.; Wong, T.H.

    2015-01-01

    Objective: Computed Tomography (CT) is the leading contributor to medical exposure to ionizing radiation. Although the use of CT brain scans for patients with head injuries and convulsions has shown a tremendous growth, it has raised substantial concerns in the general public because of the risk of radiation-induced cataracts: the current available strategies to reduce the radiation dose to the eye lens region are limited. Therefore, the present research project was initiated with the aim of evaluating the potential benefit of the combined use of bolus and a bismuth shield on reducing the radiation dose to the eye lens region during CT brain examination. Materials and methods: We conducted a series of phantom studies to measure the entrance surface dose (ESD) that is delivered to the eye lens region during CT brain examination under the effect of different scanning and shielding setups. Results: Our results indicated, during CT brain examination: (1) a drastic reduction of 92.5% in the ESD to the eye lens region was found when the CT gantry was tilted from 0 deg. (overall ESD = 30.7 mGy) to 30 deg. cranially (overall ESD = 2.4 mGy), and (2) when the CT gantry was positioned at 0 deg. (the common practice in the clinical setting), the setups with the application of a) a bismuth shield, b) a bismuth shield with a face shield (air gap), c) a bismuth shield with bolus, and d) a bismuth shield with bolus and an air gap can result in an acceptable level of image quality with a smaller overall ESD delivered to the eye lens region (overall ESD = 23.2 mGy, 24 mGy, 21 mGy and 19.9 mGy, respectively) than the setup without the bismuth shield applied (overall ESD = 30.7 mGy). Conclusion: When the primary beam scanning through the eye lens region is unavoidable during CT brain examination, the combined use of a bismuth shield with bolus and a face shield is an easy-to-use and inexpensive shielding setup to reduce the radiation dose delivered to the eye lens region while

  10. Investigation of lung nodule detectability in low-dose 320-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, J. D.; Paul, N. S.; Siewerdsen, J. H. [Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Imaging, Toronto General Hospital, Toronto, Ontario M5G 2C6 (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Ontario Cancer Institute, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2009-05-15

    Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from {approx}0.1 mGy up to that typical of low-dose CT (LDCT, {approx}5 mGy) and diagnostic CT ({approx}10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of {approx}3 (from {approx}3.3 mGy for sharp filters to {approx}1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of

  11. The effect of screening doors and windows on indoor density of Anopheles arabiensis in south-west Ethiopia: a randomized trial.

    Science.gov (United States)

    Massebo, Fekadu; Lindtjørn, Bernt

    2013-09-12

    Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings.

  12. ESR dosimetry study for the residents of Kazakhstan exposed to radioactive fallout on 24, August 1956

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, K., E-mail: kassym@hiroshima-u.ac.jp [Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8553 (Japan); Ivannikov, A. [Medical Radiological Research Center, Obninsk 249036 (Russian Federation); Zharlyganova, D. [Astana Medical University, 51a, Beibitshilik str., Astana 010000 (Kazakhstan); Zhumadilov, Zh. [Nazarbayev University, Life Sciences Center, D. Kunayev str., Astana 010000 (Kazakhstan); Stepanenko, V. [Medical Radiological Research Center, Obninsk 249036 (Russian Federation); Abralina, Sh.; Sadvokasova, L. [Semey State Medical Academy, Semey 071400, Abay str. 103 (Kazakhstan); Zhumadilova, A. [Astana Medical University, 51a, Beibitshilik str., Astana 010000 (Kazakhstan); Toyoda, S. [Department of Applied Physics, Faculty of Science, Okayama University of Science, Okayama 700-0005 (Japan); Endo, S. [Department of Quantum Energy Applications, Graduated School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Okamoto, T. [Department of Molecular Oral Medicine and Maxillofacial Surgery, Division of Frontier Medical Science, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8553 (Japan); Hoshi, M. [Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8553 (Japan)

    2011-09-15

    The method of electron spin resonance (ESR) dosimetry has been applied to human tooth enamel in order to obtain individual absorbed doses from the population of settlements within the vicinity of the central axis of the radioactive fallout trace from the contaminating nuclear surface test of 24, August 1956. Most of the settlements (Glubokoe, Tavriya, and Gagarino) are located near Ust-Kamenogorsk city, in Kazakhstan (about 400 km to the east from the epicenter of the explosion at the Semipalatinsk Nuclear Test Site (SNTS)). It was found that the excess doses obtained after the subtraction of natural background radiation ranged up to about 120 mGy for the residents of Ust-Kamenogorsk city, whose tooth enamel was formed before 1956. For the residents of Gagarino, excess doses do not exceed 47 mGy for all ages. For the residents of Tavriya, the maximum of excess dose was determined as 54 mGy and for the residents of Glubokoe, the maximum excess dose was about 83 mGy. For the population of the Shemonaikha settlements (about 70 km from the centerline of the radioactive fallout trace) the highest excess dose is 110 mGy. Also for this study, Znamenka village (about 130 km from the epicenter) was included. The Kokpekty settlement was chosen as a control and not subjected to any radioactive contamination and is located 400 km to the Southeast from SNTS.

  13. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    Science.gov (United States)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  14. Dose distribution over the radiation field and organs of the body during radiotherapy procedures

    International Nuclear Information System (INIS)

    Roy, S.; Begum, M.; Ambia, A.S.M.; Akhter, S.; Banu, H.

    2001-01-01

    Beam profile of the 60 Co teletherapy unit for 10 cm x 10 cm along central axis was measured to study the symmetry of the gamma beam and found that the average dose was 98.44±1.40 mGy. Output dose versus field size was also measured and values were found reasonable. Dose prescription to delivery was measured by placing TLD onto the treatment field for lung and cervix cancer patient which was found to be 39.16±2.98 Gy and 50.48±3.68 Gy respectively which are within 2 % and 0.17 % of the prescribed dose as 40.00 and 50.40 Gy respectively, reveals good agreement with the treatment planning. Six typical types of patients (both male and female) with cancers in lung, larynx, breast, cervix, oesophagus and brain treated with 60 Co teletherapy were particularly considered for dose assessment at different critical organs of interest. It was observed that the doses to the lens of eye with a maximum value of 460.35+78.87 mGy for a larynx cancer patient to a minimum value of 30.80+4.00 mGy of a cervix cancer patient. Doses to the gonad vary with a maximum value of 3810.80+389.76 mGy for a cervix cancer patient to a minimum value of 8.20+1.00 mGy for a brain cancer patient. (author)

  15. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  16. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  17. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  18. Virtual non-contrast of liver from dual energy CT: a clinical application

    International Nuclear Information System (INIS)

    Qian Yu'e; Hu Hongjie; Zhang Qiaowei; Hu Peng; Shen Guohui

    2011-01-01

    Objective: To assess the virtual non-contrast liver CT from dual-energy CT for the clinical application. Methods: In total, 51 patients were included in the study, and all patients underwent multi-phase liver CT on a dual-source CT. The True non-contrast liver CT (TNCT) was performed in a single-energy acquisition mode, but the arterial and portovenous liver CT (VNCT) were performed in a dual- energy mode of 110 kV and 140 kV respectively. The virtual non-contrast CT images were derived from the arterial data using liver virtual non-contrast software. Between the true non-contrast CT and the virtual non- contrast CT, the image quality, mean CT HU values in the liver and muscle, signal to noise (SNR), the radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination were compared with t test. Results: There was no significant difference in the detection of' liver lesions between TNCT and VNCT. The CT Hu values of muscle on both TNCT and VNCT images were almost equal. The CT HU values of liver on VNCT images were higher than that on TNCT images and the difference was significant [61.32±6.04 vs. (56.85±4.80) HU, t=-3.927, P<0.01]. There was also significant difference of SNR between TNCT (11.28±2.78) and VNCT (8.65±1.56) images (t=-5.590, P<0.01). The CTDIvol and DLP of single phase were (7.07±0.85) mGy and (155.11± 22.52) mGy · cm respectively in TNCT, and (7.05±0.87) mGy and (154.48±23.12) mGy · cm in VNCT. The total CTDIvol and DLP in VNCT were (14.35±1.66) mGy and (313.91±45.08) mGy · cm respectively, but in TNCT the total CTDIvol and DLP reached (21.43±2.46) mGy and (469.02± 66.22) mGy · cm. The difference of CTDIvol and DLP in single phase between TNCT and VNCT showed no significance, but the total CTDIvol and DLP were significantly different (t=16.168 and 13.132, P< 0.01). Conclusion: With the consequent reduction in radiation dose, the VNCT can replace TNCT as an imaging protocol in multi

  19. Sotsiaalkapitali roll majandusarengus / Eve Parts

    Index Scriptorium Estoniae

    Parts, Eve, 1970-

    2006-01-01

    Sotsiaalkapitali lülitamise võimalustest iseseisva lisamuutujana traditsioonilistesse kasvumudelitesse, võimalikest sisulistest mõjumehhanismidest, mõjust inimkapitalile ning institutsionaalse efektiivsuse ja sotsiaalse heaoluga seotud arengueesmärkide saavutamisele. Skeemid. Tabelid

  20. Onu Bella kollektsiooniaed / Eve Veigel

    Index Scriptorium Estoniae

    Veigel, Eve, 1961-

    2005-01-01

    Laulja, Põlva raadiojaama Marta FM pühapäevaprogrammi "Vox Humana" juhi Onu Bella (Igor Maasik) koduaiast Tartus. Onu Bella on kasvatanud roose, okaspuuvorme, praegu tegeleb mini-dendropargi rajamisega. 12 ill

  1. Pedagoogiline praktika õpetajakoolituses / Eve Eisenschmidt

    Index Scriptorium Estoniae

    Eisenschmidt, Eve, 1963-

    2003-01-01

    Lahendused pedagoogilise praktika tõhustamiseks. Pedagoogilise praktika osatähtsuse hindamiseks üliõpilaste professionaalse enesekontseptsiooni kujunemisel ja juhendaja rolli väljaselgitamisel küsitleti Haapsalu Kolledži III kursuse klassiõpetaja eriala üliõpilasi, kes viibisid I kooliastme viienädalasel praktikal 2002.a. veebruaris-märtsis

  2. Põrand kannab sisustust / Eve Variksoo

    Index Scriptorium Estoniae

    Variksoo, Eve

    1998-01-01

    Vanadest ja uutest põrandakatetest, nagu laudpõrand, laudparkett, liistparkett, laminaatpõrand, linoleum, PVC põrandakatted, kivipõrand, korkkatted, vaipkatted, sisal, kookos, keraamilised plaadid. Põrandaküttega sobivatest ja sobimatutest materjalidest. Armsast puupõrandast.

  3. Lõhe Res Publicas / Eve Heinla

    Index Scriptorium Estoniae

    Heinla, Eve, 1966-

    2005-01-01

    Tallinna linnapea Tõnis Palts on vastu Tallinna volikogu Res Publica fraktsiooni esimehe Toomas Tautsi abikaasa Kristina Tautsi tööleasumisele Lääne-Tallinna keskhaigla haldusjuhina. T. Paltsi kirjast Res Publica Tallinna piirkonna juhatusele. Lisa: Kuidas lahvatas pealinna võimutüli. Kommenteerivad: Maret Maripuu, Tõnis Palts, Vladimir Maslov

  4. Kas saatejuht vastutab? / Eve Heinla

    Index Scriptorium Estoniae

    Heinla, Eve, 1966-

    2004-01-01

    Vt. ka Vesti Dnja 22. sept., lk. 6. Urmas Oti intervjuust 15. aastase koolipoisiga Tšetšeenia teemal telesaates "Happy Hour". Lastekaitse Liidu hinnangul ei lähtunud saatejuht lapse huvidest. Lisaks: Urmas Oti küsimused tšetšeeni poisile

  5. At the Eve of Convergence?

    DEFF Research Database (Denmark)

    Henriksen, Lars Skov; Zimmer, Annette; Smith, Steven Rathgeb

    . Specifically, we will investigate whether and to what extent social services and health care in these three countries are affected by current changes. With a special focus on nonprofit organizations, we will particularly address the question whether a trend towards convergence of the very different welfare......Due to severe societal, economic and political changes, of which the financial crisis counts prominently, welfare states all over the world are under stress. In our comparative analysis, we will concentrate on specific segments of welfare state activity in Denmark, Germany, and the United States...

  6. Phototransfered thermoluminescence for dose reassessment in LiF:mg,ti , LiF: mg,Cu,p TL detectors

    International Nuclear Information System (INIS)

    Rodriguez Otazo, M.; Baly, L.

    2001-01-01

    Phototransfered Thermoluminescence (PTTL) from LiF:Mg,Ti (TLD-100) and LiF: Mg,Cu,P (GR-200) was studied at different conditions using different sources of UV light for dose reassessment purposes. The TL dosimeters were irradiated with 137Cs in the range 2 mGy to 100 mGy. The convenience of using PTTL for dose reassessment was analyzed

  7. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  8. Guidelines for the physician's behaviour after exposure of embryos or fetuses to ionizing radiation or after incorporation of radioactive substances for medical purposes

    International Nuclear Information System (INIS)

    Leppin, W.

    1980-01-01

    These guidelines intend to give the physician information on his further actions if radiation has been used in pregnant women for diagnostic purposes, and especially on the medical advice to be given to the woman. The guidelines deal mainly with radiation exposures up to a dose of 20 mGy (2 rd). The guidelines are to show that there is no indication in this dose range for the necessity of an abortion. If doses have been higher than 20 mGy (2 rd), which may be the fact in only a few cases, careful and complex diagnostic efforts are required for the decision on an abortion. The guidelines give some information also on the dose range above 20 mGy (2 rd). (orig.) [de

  9. The influence of the Lop Nor Nuclear Weapons Test Base to the population of the Republic of Kazakhstan

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, Kassym, E-mail: kassym@hiroshima-u.ac.j [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima 734-8553 (Japan); Ivannikov, Alexander [Medical Radiological Research Center, Korolev str. 4, Obninsk 249036 (Russian Federation); Zharlyganova, Dinara [Astana Medical University, Astana 010000 (Kazakhstan); Stepanenko, Valeriy [Medical Radiological Research Center, Korolev str. 4, Obninsk 249036 (Russian Federation); Zhumadilov, Zhaxybay [Nazarbayev University, Life Science Center, Astana 010000 (Kazakhstan); Apsalikov, Kazbek [Kazakh Scientific-Research Institute for Radiation Medicine and Ecology, Semey 071400 (Kazakhstan); Toyoda, Shin [Department of Applied Physics, Faculty of Science, Okayama University of Science, 1-1 Ridai, Okayama 700-0005 (Japan); Endo, Satoru [Department of Quantum Energy Applications, Graduate School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Tanaka, Kenichi [Division of Physics, Department of Liberal Arts and Sciences, Center of Medical Education, Sapporo Medical University, South 1, West 17, Chuo-ku, Sapporo 060-8556 (Japan); Miyazawa, Chuzou [School of Dentistry, Ohu University, 31-1, Aza-Misumido, Tomita-machi, Koriyama-shi, Fukushima Pref. 963-8611 (Japan); Okamoto, Tetsuji [Department of Molecular Oral Medicine and Maxillofacial Surgery, Division of Frontier Medical Sciences, Graduate School of Biomedical Sciences, Hiroshima University (Japan); Hoshi, Masaharu [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima 734-8553 (Japan)

    2011-04-15

    The method of electron spin resonance (ESR) dosimetry was applied to human tooth enamel to obtain estimates of individual absorbed dose for residents of Makanchi, Urdzhar and Taskesken settlements located near the Kazakhstan-Chinese border (about 400 km to the South-East, from the Semipalatinsk Nuclear Test Site (SNTS) and about 1000 km from the Lop Nor Nuclear Weapons Test Base, China). Since the ground and atmospheric nuclear tests (1964-1981) at Lop Nor, the people residing in these settlements are believed to have been heavily exposed to radioactive fallout. Tooth samples had been extracted for medical reasons during the course of ordinary dental treatment. The village of Kokpekty, located 400 km to the South-east of the SNTS, was chosen as the control group since it has not been subjected to any radioactive contamination. The mean excess doses in tooth enamel obtained after subtraction of the contribution of natural background radiation do not exceed 62 {+-} 28 mGy, 64 {+-} 30 mGy, 49 {+-} 27 mGy and -19 {+-} 36 mGy for all ages of the residents of Makanchi, Urdzhar, Taskesken and the control village of Kokpekty, respectively.

  10. Chromosomal aberrations of blood lymphocytes induced in vitro by radon-222 daughter α-irradiation

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.; Lettner, H.; Hofmann, W.; Atzmueller, C; Eckl, P.; Haas, O.A.; Obe, G.; Grell-Buechtmann, I.; Van Buul, P.P.W.; Natarajan, A.T.; Schroeder-Kurth, T.; Sasaki, M.S.; Fischer, P.; Kubiak, R.

    2000-01-01

    Blood samples were irradiated in vitro with α-rays emitted from short-lived radon decay products dissolved in the culture medium at doses between 0.03 and 41.4 mGy. The data were collected from experiments conducted during the period 1984-1992 and comprise a total of about 64000 scored metaphases. For statistical reasons, only 60,022 metaphases were used for the subsequent analysis. The results for total chromosome aberrations and dicentrics indicate a linear dose dependence in the dose range above about 10 mGy, consistent with other experimental observations. At doses below about 10 mGy, aberration frequencies cannot be linearly extrapolated from higher doses, suggesting that there is no dependence on dose within a certain low-dose range. In addition, a statistically significant minimum has been observed at a dose of about 0.03 mGy, which is consistently lower than the related control values. The behavior of the aberration frequencies in the low-dose region seems to be influenced by the control values, which also depend on the environmental radiation burdens to the donors before blood sampling and thus were significantly affected by the Chernobyl fallout

  11. A cytogenetic study on persons exposed to 241Am-Be neutron source

    International Nuclear Information System (INIS)

    Bai Yushu; Zhang Xiuxia; Guan Shurong; Xie Feng; Lu Meiying

    1988-01-01

    An 241 Am-Be neutron source of 120 millicrocurie was stolen by a boy on April the 3rd, 1982. He brought it to his home. The neutron source was broken and the radioactive substance contaminated the whole family. He and his other family members did not leave the contaminated environment for 70 days. There were altogether 14 persons exposed to the radioactive substances. Chromosome aberrations of peripheral blood lymphocytes of six exposed cases were analysed on an early day of June 1982. The exposure doses were estimated by the frequency of chromosome aberration. Biological dose absorbed by the boy who stole the source was about 96 ∼ 128 mGy (physical dose about 120 mGy), the others were about 10 ∼ 30 mGy (physical dose about 10 ∼ 30 mGy). The results indicated that biological dose were quite approximate to the physical doses. One and half years after the accident, the analysis of stable chromosome aberrations for 14 exposed persons showed that the frequencies of chromosome aberrations of the irradiated individuals were still higher than those of the controls. The differences between them are very significant

  12. Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudan

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Khalil, M.

    2011-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) procedure is an invasive technique that requires fluoroscopic and radiographic exposure. The purpose of this study was to determine the occupational dose of ionising radiation at three gastroenterology departments (Fedial, Soba and Ibn seena hospitals) in Khartoum (Sudan). The radiation dose was measured during 55 therapeutic ERCP procedures. Thermoluminescence dosemeters were used. The mean radiation dose for the first operator was 0.27 mGy for the eye lens, 0.21 for the thyroid, 0.32 for the chest, 0.17 for the hand and 0.22 for the leg. The mean radiation dose for the second operator was 0.21 mGy for the hand and 0.20 mGy for the chest, while the mean radiation dose for the nurse was 0.44 mGy for the hand and 0.19 for the chest. The radiation dose received by the staff in these hospitals was found to be higher than most of the values in the literature. The radiation absorbed dose received by the different organs is relatively low. Additional studies need to be conducted for radiation dose optimisation. (authors)

  13. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A.; Elzaki, M. [Sudan University of Science and Technology, College of Medical Radiologic Science, P. O. Box 1908, Khartoum 11111 (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Abuzaid, M. [University of Sharjah, College of Health Sciences, Medical Diagnostic Imaging Department, Sharjah (United Arab Emirates); Dalton, A.; Bradley, D., E-mail: Abdelmoneim_a@yahoo.com [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, GU2-7XH, Guildford, Surrey (United Kingdom)

    2015-10-15

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  14. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Alkhorayef, M.; Babikir, E.; Abuzaid, M.; Dalton, A.; Bradley, D.

    2015-10-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  15. Establishment of diagnostic reference levels for dental panoramic radiography in Greece

    International Nuclear Information System (INIS)

    Manousaridis, G.; Koukorava, C.; Hourdakis, C.J.; Kamenopoulou, V.; Yakoumakis, E.; Tsiklakis, K.

    2015-01-01

    The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values. DRL values have been proposed for exposure settings of different patient types (child, small adult and standard adult), both for film and digital imaging. The DRLs for different patient types are grouped in three categories: children, small adults (corresponding to female) and average adults (corresponding to male). Proposed DRLs for these groups are 2.2, 3.3 and 4.1 mGy, respectively. In order to investigate the correlation of DRLs with the available imaging modalities (CR, DR and film), this parameter was taken into account. DR imaging DRL is the lowest at 3.5 mGy, CR imaging the highest at 4.2 mGy and film imaging at 3.7 mGy. In order to facilitate comparison with other studies, kerma-width product values were calculated from K i , air and field size. (authors)

  16. Towards establishing DRLs for digital mammography in Australia

    International Nuclear Information System (INIS)

    Diffey, J.L; Carteright, L.E.; Collins, L.T.; Grewal, R.K.

    2011-01-01

    Full text: Breastscreen NSW is one of the first breast screening programs to be fully digital. Exposure data is stored in the DICOM image header, making it readily accessible for assessing patient dose. The aim of this work was to determine diagnostic reference levels (DRLs) for the screening program. Approximately 100 examinations, consisting of two views of each breast, were obtained for each system from the central PACS. Third party software was then used to extract the relevant exposure parameters. The mean glandular dose (MGD) was calculated for each image using the methods described by Wu, Boone and Dance. The DRL was calculated from the average mean glandular dose for mediolateral oblique (MLO) views with compressed breast thicknesses of 50-60 mm. For the whole sample, the average MLO compressed breast thickness was 58.84 mm with an average compression force of 109.25 N. The average MGD (Dance) for each examination was 2.93 mGy, compared with 4.6 mGy for film-screen systems. The DRL for CR systems (Dance) was 1.85 mGy, and for DR systems it was 1.13 mGy.

  17. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Schandorf, C.; Tetteh, G.K

    1998-07-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  18. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    International Nuclear Information System (INIS)

    Schandorf, C.; Tetteh, G.K.

    1998-01-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  19. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  20. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  1. Optimal conditions of LDR to protect the kidney from diabetes

    Science.gov (United States)

    Cheng, Jie; Li, Fengsheng; Cui, Jiuwei; Guo, Weiying; Li, Cai; Li, Wei; Wang, Guixia; Xing, Xiao; Gao, Ying; Ge, Yuanyuan; Wang, Guanjun; Cai, Lu

    2014-01-01

    Aims We reported the attenuation of diabetes-induced renal dysfunction by exposure to multiple low-dose radiation (LDR) at 25 mGy every other day via suppressing renal oxidative damage. We here explored the optimal conditions of LDR to protect the kidney from diabetes. Main methods Type 1 diabetic mice were induced with multiple injections of low-dose streptozotocin in male C57BL/6J mice. Diabetic mice received whole body X-irradiation at dose of 12.5, 25 or 50 mGy every other day for either 4 or 8 weeks. Age-matched normal mice were similarly irradiated at the dose of 25 mGy for 4 or 8 weeks. The renal function and histopathological changes were examined at the 4th and 8th week of the study. Key findings Diabetes induced renal dysfunction, shown by the decreased creatinine and increased microalbumin in urinary. Renal oxidative damage, detected by protein nitration and lipid oxidation, and remodeling, reflected by increased expression of connective tissue growth factor, collagen IV and fibronectin, were significantly increased in diabetic mice. All these renal pathological and function changes in diabetic mice were significantly attenuated by exposure to LDR at all regimens, among which, however, exposure to LDR at 12.5 mGy for 8 weeks provided the best preventive effect on the kidney of diabetic mice. Significance Our results suggest that whole-body LDR at 12.5 mGy every other day for 8 weeks is the optimal condition of LDR to protect the kidney from diabetes. PMID:24631139

  2. The effects of rat's sperm bioassay for low dose X-ray

    International Nuclear Information System (INIS)

    Jin, Gye Hwan; Min, Soo Young; Lee, Sang Bock; Lee, Sam Yul; Lee, Jun Haeng; Park, Jong Bae

    2007-01-01

    In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley (SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group. All the groups showed slightly increasing number of sperms per 0.1 g semen (14.216 x 10 6 , 13.901 x 10 6 , 14.153 x 10 6 , 13.831 x 10 6 , 14.137 x 10 6 , 14.677 x 10 6 respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body

  3. Exploring if day and time of admission is associated with average length of stay among inpatients from a tertiary hospital in Singapore: an analytic study based on routine admission data.

    Science.gov (United States)

    Earnest, Arul; Chen, Mark I C; Seow, Eillyne

    2006-01-22

    It has been postulated that patients admitted on weekends or after office hours may experience delays in clinical management and consequently have longer length of stay (LOS). We investigated if day and time of admission is associated with LOS in Tan Tock Seng Hospital (TTSH), a 1,400 bed acute care tertiary hospital serving the central and northern regions of Singapore. This was a historical cohort study based on all admissions from TTSH from 1st September 2003 to 31st August 2004. Data was extracted from routinely available computerized hospital information systems for analysis by episode of care. LOS for each episode of care was log-transformed before analysis, and a multivariate linear regression model was used to study if sex, age group, type of admission, admission source, day of week admitted, admission on a public holiday or eve of public holiday, admission on a weekend and admission time were associated with an increased LOS. In the multivariate analysis, sex, age group, type of admission, source of admission, admission on the eve of public holiday and weekends and time of day admitted were independently and significantly associated with LOS. Patients admitted on Friday, Saturday or Sunday stayed on average 0.3 days longer than those admitted on weekdays, after adjusting for potential confounders; those admitted on the eve of public holidays, and those admitted in the afternoons and after office hours also had a longer LOS (differences of 0.71, 1.14 and 0.65 days respectively). Cases admitted over a weekend, eve of holiday, in the afternoons, and after office hours, do have an increased LOS. Further research is needed to identify processes contributing to the above phenomenon.

  4. Exploring if day and time of admission is associated with average length of stay among inpatients from a tertiary hospital in Singapore: an analytic study based on routine admission data

    Directory of Open Access Journals (Sweden)

    Chen Mark IC

    2006-01-01

    Full Text Available Abstract Background It has been postulated that patients admitted on weekends or after office hours may experience delays in clinical management and consequently have longer length of stay (LOS. We investigated if day and time of admission is associated with LOS in Tan Tock Seng Hospital (TTSH, a 1,400 bed acute care tertiary hospital serving the central and northern regions of Singapore. Methods This was a historical cohort study based on all admissions from TTSH from 1st September 2003 to 31st August 2004. Data was extracted from routinely available computerized hospital information systems for analysis by episode of care. LOS for each episode of care was log-transformed before analysis, and a multivariate linear regression model was used to study if sex, age group, type of admission, admission source, day of week admitted, admission on a public holiday or eve of public holiday, admission on a weekend and admission time were associated with an increased LOS. Results In the multivariate analysis, sex, age group, type of admission, source of admission, admission on the eve of public holiday and weekends and time of day admitted were independently and significantly associated with LOS. Patients admitted on Friday, Saturday or Sunday stayed on average 0.3 days longer than those admitted on weekdays, after adjusting for potential confounders; those admitted on the eve of public holidays, and those admitted in the afternoons and after office hours also had a longer LOS (differences of 0.71, 1.14 and 0.65 days respectively. Conclusion Cases admitted over a weekend, eve of holiday, in the afternoons, and after office hours, do have an increased LOS. Further research is needed to identify processes contributing to the above phenomenon.

  5. The effects of γ-ray on charging behaviour using polyimide

    Science.gov (United States)

    Qin, Sichen; Tu, Youping; Tan, Tian; Wang, Shaohe; Yuan, Zhikang; Wang, Cong; Li, Laifeng; Wu, Zhixiong

    2018-06-01

    Insulation material is a key component of electrical equipment in satellites; its electrical properties determine the reliability and lifetime of the whole satellite. High-energy radioactive rays in space affect the molecular structure of the polymeric insulating materials. Under the action of plasma, high energy particles, along with the magnetic fields experienced in orbits, electric charges get injected into and trapped by the insulating material creating distortions in the electric field and even electrostatic discharges. Polyimides have been widely used for insulation in spacecraft. Choosing Co-60 gamma ray with irradiation doses of 1 MGy and 5 MGy to simulate the radiation environment of space, we investigated the effect of radiation on charging behaviour. The thermal stimulated current (TSC) from a high electric field over a wide range of temperatures was measured from which the activation energy was calculated. These results for the two sources show that the percentage increase in total charge was 133.3% and 119.4%. The γ, β 3, and α charge peaks of specimens after an irradiation dose of 1 MGy rose. In comparison, the β 2 peak of the 5 MGy-dosed specimens was enhanced. Also, there is almost no change in the γ, β 3, and α peaks. To understand the mechanism behind the TSC changes, the resulting physicochemical characteristics of an irradiated specimen were observed employing various analyses of chemical characteristics (x-ray photoelectron spectroscopy, differential scanning calorimetry and x-ray diffraction). Compared with the non-dosed specimen, the relative content of C–N and the glass transition temperature of the 1 MGy sample decreased, and the crystallinity increased, thus increasing the γ and α peak intensities. Compared with the 1 MGy sample, only the glass transition temperature had risen, thereby enhancing the β peak intensity. With the foregoing, a theoretical base for the selection and modification of insulation materials for

  6. Orthopaedic surgeries - assessment of ionising radiations exposure in health care workers

    International Nuclear Information System (INIS)

    Leite, E.S.; Uva, A.S.

    2006-01-01

    Full text of publication follows: 1. Objectives: The health care workers are exposed to ionizing radiations during their activities. In the operating rooms, the ionizing radiations are used in orthopaedic surgery and the dose depends on some factors, like the characteristics of the equipment. This study aims to: Estimate the occupational dose of ionizing radiations exposure of the orthopaedic doctors and nurses during the orthopaedic surgeries, in a Portuguese operating room; Sensitize the health care workers to use the individual dosimeter and to adopt radiation preventive measures. 2. Population and methods The study was conducted on nine Orthopaedic doctors and two nurses of an operating room of a hospital in Lisbon neighborhoods. We made a risk evaluating concerning: the radiations dose in different points, corresponding to gonads, hands and crystalline lens levels of all the professionals, during the surgeries; the average period of radiation in the orthopaedic surgeries; the number of annual orthopaedic surgeries, looking for that in the surgeries registers, to estimate the annual ionizing radiations dose of each orthopaedic doctor and nurse. 3. Results The annual doses estimated at different levels for orthopaedic doctors were the following: gonads: between 20,63 and 68,75 mGy; hands: 4,95 16,50 mGy; crystalline lens: 8,25 27,50 mGy). For the orthopaedic nurses: gonads: 130,63 151,25 mGy; hands: 31,35 36,30 mGy; crystalline lens 52,25 60,25 mGy. 4. Conclusions Although the location and positions of health care workers are not the same during the different surgeries and the equipment has an automatic control of the X ray emission, the annual ionizing radiations dose exposure for health care workers is an important one. The risk rating justifies the use of individual dosimeters for better individual dose assessment as part of an ionizing radiations prevention program. As a matter of fact preventive measures begin with a good quantitative risk assessment of

  7. Assessment of mean glandular dose for patients in mammography in some Hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Abu Elmola, Alaa Mahdi

    2016-12-01

    A mammography examination facilitates the early detection of breast cancer. However, the potential risk of radiation- induced carcinogenesis is also increased with such a procedure. Thus assessment of the breast dose is important. The objective of this study was to determine the mean glandular dose (MGD) resulting from cranio caudal(CC) and mediolateral oblique (MLO) views in one breast and the total dose per woman in Sudan, and to identify the factors affecting it. Measurements were performed to estimate mean glandular doses for 60 patients who underwent mammography examination in two clinics in Khartoum, Sudan.Doses were studied in RCH and NDC, centers which were using computed radiography(CR)devices. The piranha system was used for determining the MGD in this work. The characteristics of the radiographic equipment and the exposure data of each patient were recorded using designed format. The MGD was calculated from the measured incident Air kerma using appropriate conversion coefficients. The range of CBT was (1-7)cm for two projections. The respective averages for the CC and MLO projections were (4.55±1.38)mGy and (4.15±1.33) mGy, respectively. The average MGD per image was (4.3±1.35)mGy. The MGD per women was (8.6±1.35)mGy. The mean±SD MGD per image in the present study was lower than most of similar reports. The average MGD values recorded in this study were above the limiting value of the Institute of Physical Sciences in Medicine(2.0 mGy) and American College of Radiology (3.0 mGy recommendation. This suggests that mammography x-ray generators in this case are not capable of achieving acceptable dose levels for patients safety. Therefore, with consideration of all other factors, quality control program tests must be carried out periodically and frequently of the mammography equipment.(Author)

  8. Evaluation of dose to tooth enamel from medical diagnostic X-ray examinations at Mayak PA

    Energy Technology Data Exchange (ETDEWEB)

    Wieser, A., E-mail: wieser@helmholtz-muenchen.de [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany); Vasilenko, E. [Mayak Production Association, 456780 Ozyorsk (Russian Federation); Zankl, M.; Greiter, M.; Ulanovsky, A. [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany); Sabayev, A.; Knyazev, V.; Zahrov, P. [Mayak Production Association, 456780 Ozyorsk (Russian Federation)

    2011-09-15

    The nuclear workers of the Mayak Production Association had regular check-ups including medical diagnostic X-ray examinations since start of the production lines in 1948. Doses from diagnostic examinations need to be considered in reconstruction of occupational doses of the workers with electron paramagnetic resonance (EPR) of tooth enamel. The numbers and types of examinations of an individual worker can be assessed from the Mayak PA archives but no information was available on doses delivered to teeth by a single specific examination. Of the twenty one applied examination procedures only three affected the teeth, these being X-ray examinations of teeth, skull and cervical spine. For these three kinds of examinations operational procedures and operating modes of X-ray units were compiled from the archive and photon spectra were obtained from a catalog of spectral data for diagnostic X-rays. Entrance doses in air kerma were calculated using the fluence of photon spectra and absorbed dose in tooth enamel for various tooth positions and exposure geometry was then calculated using dose conversion coefficients obtained from Monte Carlo simulations. Doses were calculated for examinations in 1948-2000. Except for examination of the skull, absorbed doses in enamel of incisors were found to be about twice as large as in enamel of molars. In the period before 1970 the largest mean absorbed doses in tooth enamel were due to X-ray examination of teeth, with 64 mGy and 34 mGy calculated for incisors and molars, respectively. In the same period the lowest mean doses were due to X-ray examination of the skull, with 11 mGy and 12 mGy calculated for incisors and molars, respectively. In the period from 1970 to 2000, largest mean doses in enamel were due to X-ray examination of cervical spine, with 23 mGy and 12 mGy calculated for incisors and molars, respectively.

  9. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  10. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    Science.gov (United States)

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  11. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jallow, N [Emory University, Atlanta, GA (United States); Sechopoulos, I [Radboud University Medical Centre, Nijmegen (Netherlands)

    2016-06-15

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.

  12. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    International Nuclear Information System (INIS)

    Jallow, N; Sechopoulos, I

    2016-01-01

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.

  13. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  14. Optimization of pediatric examinations in a multislice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Ombada, T H. A. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI{sub v}ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI{sub v}ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  15. Fetal shielding combined with state of the art CT dose reduction strategies during maternal chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Chatterson, Leslie C., E-mail: lch088@mail.usask.ca [Department of Diagnostic Imaging, University of Saskatchewan (Canada); Leswick, David A.; Fladeland, Derek A. [Department of Diagnostic Imaging, University of Saskatchewan (Canada); Hunt, Megan M.; Webster, Stephen [Saskatchewan Ministry of Labour Relations and Workplace Safety (Canada); Lim, Hyun [Department of Community Health and Epidemiology, College of Medicine, University of Saskatchewan (Canada)

    2014-07-15

    Purpose: Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. Materials and methods: A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Results: Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P < 0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P < 0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P = 0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P = 0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). Conclusion: ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal

  16. Fetal shielding combined with state of the art CT dose reduction strategies during maternal chest CT

    International Nuclear Information System (INIS)

    Chatterson, Leslie C.; Leswick, David A.; Fladeland, Derek A.; Hunt, Megan M.; Webster, Stephen; Lim, Hyun

    2014-01-01

    Purpose: Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. Materials and methods: A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Results: Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P < 0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P < 0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P = 0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P = 0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). Conclusion: ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal

  17. Quantifying murine bone marrow and blood radiation dose response following {sup 18}F-FDG PET with DNA damage biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Grainne [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Taylor, Kristina [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON (Canada); Finnon, Paul [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Lemon, Jennifer A.; Boreham, Douglas R. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON (Canada); Badie, Christophe, E-mail: christophe.badie@phe.gov.uk [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom)

    2014-12-15

    Highlights: • Mice received either a range of {sup 18}F-FDG activities or whole body X-ray doses. • Blood samples were collected at 24 and 43 h for MN-RET and QPCR analysis. • Regression analysis showed that both types of exposure produced a linear response. • BM doses of 33 mGy ({sup 18}F-FDG) and 25 mGy X-rays were significantly higher than controls. • No significant difference between internal ({sup 18}F-FDG) and external (X-ray) was found. - Abstract: The purpose of this study was to quantify the poorly understood radiation doses to murine bone marrow and blood from whole-body fluorine 18 ({sup 18}F)-fluorodeoxyglucose (FDG) positron emission tomography (PET), by using specific biomarkers and comparing with whole body external low dose exposures. Groups of 3–5 mice were randomly assigned to 10 groups, each receiving either a different activity of {sup 18}F-FDG: 0–37 MBq or whole body irradiated with corresponding doses of 0–300 mGy X-rays. Blood samples were collected at 24 h and at 43 h for reticulocyte micronucleus assays and QPCR analysis of gene expression in peripheral blood leukocytes. Blood and bone marrow dose estimates were calculated from injected activities of {sup 18}F-FDG and were based on a recommended ICRP model. Doses to the bone marrow corresponding to 33.43 mGy and above for internal {sup 18}F-FDG exposure and to 25 mGy and above for external X-ray exposure, showed significant increases in radiation-induced MN-RET formation relative to controls (P < 0.05). Regression analysis showed that both types of exposure produced a linear response with linear regression analysis giving R{sup 2} of 0.992 and 0.999 for respectively internal and external exposure. No significant difference between the two data sets was found with a P-value of 0.493. In vivo gene expression dose–responses at 24 h for Bbc3 and Cdkn1 were similar for {sup 18}F-FDG and X-ray exposures, with significant modifications occurring for doses over 300 mGy for Bbc3

  18. Security proof of counterfactual quantum cryptography against general intercept-resend attacks and its vulnerability

    International Nuclear Information System (INIS)

    Zhang Sheng; Wang Jian; Tang Chao-Jing

    2012-01-01

    Counterfactual quantum cryptography, recently proposed by Noh, is featured with no transmission of signal particles. This exhibits evident security advantages, such as its immunity to the well-known photon-number-splitting attack. In this paper, the theoretical security of counterfactual quantum cryptography protocol against the general intercept-resend attacks is proved by bounding the information of an eavesdropper Eve more tightly than in Yin's proposal [Phys. Rev. A 82 042335 (2010)]. It is also shown that practical counterfactual quantum cryptography implementations may be vulnerable when equipped with imperfect apparatuses, by proving that a negative key rate can be achieved when Eve launches a time-shift attack based on imperfect detector efficiency. (general)

  19. Ultra low-dose chest CT using filtered back projection: Comparison of 80-, 100- and 120 kVp protocols in a prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, Ranish Deedar Ali, E-mail: rkhawaja@mgh.harvard.edu [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States); Singh, Sarabjeet [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States); Madan, Rachna [Division of Thoracic Radiology, Brigham and Women' s Hospital and Harvard Medical School, Boston (United States); Sharma, Amita; Padole, Atul; Pourjabbar, Sarvenaz; Digumarthy, Subba; Shepard, Jo-Anne; Kalra, Mannudeep K. [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States)

    2014-10-15

    Highlights: • Filtered back projection technique enables acceptable image quality for chest CT examinations at 0.9 mGy (estimated effective dose of 0.5 mSv) for selected sizes of patients. • Lesion detection (such as solid non-calcified lung nodules) in lung parenchyma is optimal at 0.9 mGy, with limited visualization of thyroid nodules in FBP images. • Further dose reduction down to 0.4 mGy is possible for most patients undergoing follow-up chest CT for evaluation of larger lung nodules and GGOs. • Our results may help set the reference ALARA dose for chest CT examinations reconstructed with filtered back projection technique using the minimum possible radiation dose with acceptable image quality and lesion detection. - Abstract: Purpose: To assess lesion detection and diagnostic image quality of filtered back projection (FBP) reconstruction technique in ultra low-dose chest CT examinations. Methods and materials: In this IRB-approved ongoing prospective clinical study, 116 CT-image-series at four different radiation-doses were performed for 29 patients (age, 57–87 years; F:M – 15:12; BMI 16–32 kg/m{sup 2}). All patients provided written-informed-consent for the acquisitions of additional ultra low-dose (ULD) series on a 256-slice MDCT (iCT, Philips Healthcare). In-addition to their clinical standard-dose chest CT (SD, 120 kV mean CTDI{sub vol}, 6 ± 1 mGy), ULD-CT was subsequently performed at three-dose-levels (0.9 mGy [120 kV]; 0.5 mGy [100 kV] and 0.2 mGy [80 kV]). Images were reconstructed with FBP (2.5 mm * 1.25 mm) resulting into four-stacks: SD-FBP (reference-standard), FBP{sub 0.9}, FBP{sub 0.5}, and FBP{sub 0.2}. Four thoracic-radiologists from two-teaching-hospitals independently-evaluated data for lesion-detection and visibility-of-small-structures. Friedman's-non-parametric-test with post hoc Dunn's-test was used for data-analysis. Results: Interobserver-agreement was substantial between radiologists (k = 0.6–0.8). With

  20. Foot strike pattern in preschool children during running: sex and shod-unshod differences.

    Science.gov (United States)

    Latorre-Román, Pedro Á; Párraga-Montilla, Juan A; Guardia-Monteagudo, Ignacio; García-Pinillos, Felipe

    2018-04-01

    This study aims to determine the foot strike patterns (FSPs) and neutral support (no inversion [INV]/eversion [EVE] and no foot rotation) in preschool children, as well as to determine the influence of shod/unshod conditions and sex. A total of 1356 children aged 3-6 years (673 boys and 683 girls) participated in this study. A sagittal and frontal-plane video (240 Hz) was recorded using a high-speed camcorder to record the following variables: rearfoot strike (RFS), midfoot strike (MFS), forefoot strike (FFS), inversion/ eversion (INV/EVE) and foot rotation on initial contact. There were no between-sex significant differences in both shod and unshod conditions in RFS. In the unshod condition, there was a significant reduction (p < 0.001) of RFS prevalence in both boys (shod condition = 44.2% vs. 34.7% unshod condition) and girls (shod condition = 48.5% vs. 36.1% unshod condition). As for neutral support, there were no between-sex differences in both shod and unshod conditions or in the shod-unshod comparison. In preschool children, no between-sex differences were found in relation to prevalence of RFS and neutral support (no INV/EVE). Shod running alters FSP of running barefoot, producing a significant increase of RFS prevalence.

  1. Stochastic model for gene transcription on Drosophila melanogaster embryos

    Science.gov (United States)

    Prata, Guilherme N.; Hornos, José Eduardo M.; Ramos, Alexandre F.

    2016-02-01

    We examine immunostaining experimental data for the formation of stripe 2 of even-skipped (eve) transcripts on D. melanogaster embryos. An estimate of the factor converting immunofluorescence intensity units into molecular numbers is given. The analysis of the eve dynamics at the region of stripe 2 suggests that the promoter site of the gene has two distinct regimes: an earlier phase when it is predominantly activated until a critical time when it becomes mainly repressed. That suggests proposing a stochastic binary model for gene transcription on D. melanogaster embryos. Our model has two random variables: the transcripts number and the state of the source of mRNAs given as active or repressed. We are able to reproduce available experimental data for the average number of transcripts. An analysis of the random fluctuations on the number of eves and their consequences on the spatial precision of stripe 2 is presented. We show that the position of the anterior or posterior borders fluctuate around their average position by ˜1 % of the embryo length, which is similar to what is found experimentally. The fitting of data by such a simple model suggests that it can be useful to understand the functions of randomness during developmental processes.

  2. Evaluation of average glandular dose in mammography services in 10 cities of Colombia

    International Nuclear Information System (INIS)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D.

    2016-01-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  3. Evaluation of average glandular dose in mammography services in 10 cities of Colombia; Avaliacao de dose glandular media em servicos de mamografia de 10 cidades de Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D. [Grupo de Prevencion Temprana Del Cancer, Instituto Nacional de Cancerologia, Bogota D.C. (Colombia)

    2016-07-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  4. Evidence for radiation induced crosslinking in polytetrafluoroethylene by means of high-resolution solid-state 19F high-speed MAS NMR

    International Nuclear Information System (INIS)

    Katoh, Etsuko; Sugisawa, Hisashi; Oshima, Akihiro; Tabata, Yoneho; Seguchi, Tadao; Yamazaki, Toshimasa

    1999-01-01

    Radiation effects on molecular structure of polytetrafluoroethylene (PTFE) were studied by high-resolution solid-state 19 F high speed magic angle spinning (HS MAS) NMR spectroscopy. Samples used for the NMR studies were prepared by electron beam irradiation of PTFE with a wide range of irradiation doses from 0.5-10 MGy in the molten state at 340 deg. C under oxygen-free atmosphere. While the non-irradiated PTFE displayed only an intense peak of the internal CF 2 , several new signals corresponding to CF 3 , CF 2 and CF groups were observed for the PTFE which was high temperature irradiated at 340 deg. C in oxygen-free atmosphere (hti-PTFE). Intensities of these new signals increased with an increase of irradiation dose. The present solid-state 19 F HS MAS NMR studies provide not only the first experimental evidence regarding the existence of crosslinking structure in hti-PTFE, directly detected as the CF signal, but also the crosslinking density which can be estimated from a proportion of the CF versus total fluorine signal intensities. The higher the irradiation dose, the higher the crosslinking density; hti-PTFE with 10 MGy contains one crosslinking site per approximately 24 CF 2 groups, while the hti-PTFE with 5 MGy contains one crosslinking site per approximately 36 CF 2 groups. Further, G value of crosslinking (G(x)) was estimated from the signal intensities of 19 F HS MAS NMR spectra. The highest G(x)-value, 1.85, was observed for the 2MGy hti-PTFE sample, suggesting that crosslinking of PTFE is formed most efficaciously with 2 MGy irradiation in the molten state at 340 deg. C under oxygen-free atmosphere

  5. Effect of continuous exposure to very low dose rates of gamma rays on life span and neoplasia in mice

    International Nuclear Information System (INIS)

    Tanaka, I.B. III; Tanaka, Satoshi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Oghiso, Yoichi; Sato, Fumiaki; Matsushita, Satoru

    2008-01-01

    Late effects of continuous exposure to ionizing radiation are potential hazards to workers in radiation facilities as well as to the general public. In the recent years, low-dose-rate and low-dose effects have become a serious concern. Using a total of 4,000 mice, we studied the late biological effects of chronic exposure to low-dose-rate radiation on life span and neoplasia. Two thousand male and 2000 female 8-week-old specific pathogen free (SPF) B6C3F1 mice were randomly divided into 4 groups, one non-irradiated (control) and three irradiated. The irradiated groups were exposed to 137 Cs gamma rays at dose-rates of 21, 1.1 and 0.05 mGy day -1 for approximately 400 days with total doses equivalent to 8000, 400 and 20 mGy, respectively. All mice were kept under SPF conditions until natural death and pathological examination was performed to determine the cause of death. Statistical analyses showed that the life spans of mice of both sexes irradiated with 21 mGy day -1 (P -1 (P 86.7% of all deaths. Compared to the non-irradiated controls, incidences of lethal neoplasms were significantly increased for myeloid leukaemia and hemangiosarcoma in males, soft tissue neoplasms and malignant granulosa cell tumors in females exposed to 21 mGy day -1 . The number of multiple primary neoplasms per mouse was significantly increased in mice irradiated at 21 mGy day -1 . Our results suggest that life shortening in mice continuously exposed to low dose-rate gamma rays is due to early death from a variety of neoplasms and not from increased incidence of specific lethal neoplasms. (author)

  6. Non-induction of radioadaptive response in zebrafish embryos by neutrons

    International Nuclear Information System (INIS)

    Ng, Candy Y.P.; Kong, Eva Y.; Kobayashi, Alisa; Suya, Noriyoshi; Uchihori, Yukio; Cheng, Shuk Han; Konishi, Teruaki; Yu, Kwan Ngok

    2016-01-01

    In vivo neutron-induced radioadaptive response (RAR) was studied using zebrafish (Danio rerio) embryos. The Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility at the National Institute of Radiological Sciences (NIRS), Japan, was employed to provide 2-MeV neutrons. Neutron doses of 0.6, 1, 25, 50 and 100 mGy were chosen as priming doses. An X-ray dose of 2 Gy was chosen as the challenging dose. Zebrafish embryos were dechorionated at 4 h post fertilization (hpf), irradiated with a chosen neutron dose at 5 hpf and the X-ray dose at 10 hpf. The responses of embryos were assessed at 25 hpf through the number of apoptotic signals. None of the neutron doses studied could induce RAR. Non-induction of RAR in embryos having received 0.6- and 1-mGy neutron doses was attributed to neutron-induced hormesis, which maintained the number of damaged cells at below the threshold for RAR induction. On the other hand, non-induction of RAR in embryos having received 25-, 50- and 100-mGy neutron doses was explained by gamma-ray hormesis, which mitigated neutron-induced damages through triggering high-fidelity DNA repair and removal of aberrant cells through apoptosis. Separate experimental results were obtained to verify that high-energy photons could disable RAR. Specifically, 5- or 10-mGy X-rays disabled the RAR induced by a priming dose of 0.88 mGy of alpha particles delivered to 5-hpf zebrafish embryos against a challenging dose of 2 Gy of X-rays delivered to the embryos at 10 hpf

  7. Radiation doses to patients receiving computed tomography examinations in British Columbia

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Bilawich, A.-M.; Mayo, J.R.

    2006-01-01

    To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen/pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen/pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany. (author)

  8. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  9. Assessment of medical radiation exposure to patients and ambient doses in several diagnostic radiology departments

    Science.gov (United States)

    Sulieman, A.; Elhadi, T.; Babikir, E.; Alkhorayef, M.; Alnaaimi, M.; Alduaij, M.; Bradley, D. A.

    2017-11-01

    In many countries diagnostic medical exposures typically account for a very large fraction of the collective effective dose that can be assigned to anthropological sources and activities. This in part flags up the question of whether sufficient steps are being taken in regard to potential dose saving from such medical services. As a first step, one needs to survey doses to compare against those of best practice. The present study has sought evaluation of the radiation protection status and patient doses for certain key radiological procedures in four film-based radiology departments within Sudan. The radiation exposure survey, carried out using a survey meter and quality control test tools, involved a total of 299 patients their examinations being carried out at one or other of these four departments. The entrance surface air kerma (ESAK) was determined from exposure settings using DosCal software and an Unfors -Xi-meter. The mean ESAK for x-ray examination of the chest was 0.30±0.1 mGy, for the skull it was 0.96±0.7 mGy, for the abdomen 0.85±0.01 mGy, for spinal procedures 1.30±0.6 mGy and for procedures involving the limbs it was 0.43±0.3 mGy. Ambient dose-rates in the reception area, at the closed door of the x-ray room, recorded instantaneous values of up to 100 μSv/h. In regard to protection, the associated levels were found to be acceptable in three of the four departments, corrective action being required for one department, regular quality control also being recommended.

  10. Improving anxiety regulation in patients with breast cancer at the beginning of the survivorship period: a randomized clinical trial comparing the benefits of single-component and multiple-component group interventions.

    Science.gov (United States)

    Merckaert, Isabelle; Lewis, Florence; Delevallez, France; Herman, Sophie; Caillier, Marie; Delvaux, Nicole; Libert, Yves; Liénard, Aurore; Nogaret, Jean-Marie; Ogez, David; Scalliet, Pierre; Slachmuylder, Jean-Louis; Van Houtte, Paul; Razavi, Darius

    2017-08-01

    To compare in a multicenter randomized controlled trial the benefits in terms of anxiety regulation of a 15-session single-component group intervention (SGI) based on support with those of a 15-session multiple-component structured manualized group intervention (MGI) combining support with cognitive-behavioral and hypnosis components. Patients with nonmetastatic breast cancer were randomly assigned at the beginning of the survivorship period to the SGI (n = 83) or MGI (n = 87). Anxiety regulation was assessed, before and after group interventions, through an anxiety regulation task designed to assess their ability to regulate anxiety psychologically (anxiety levels) and physiologically (heart rates). Questionnaires were used to assess psychological distress, everyday anxiety regulation, and fear of recurrence. Group allocation was computer generated and concealed till baseline completion. Compared with patients in the SGI group (n = 77), patients attending the MGI group (n = 82) showed significantly reduced anxiety after a self-relaxation exercise (P = .006) and after exposure to anxiety triggers (P = .013) and reduced heart rates at different time points throughout the task (P = .001 to P = .047). The MGI participants also reported better everyday anxiety regulation (P = .005), greater use of fear of recurrence-related coping strategies (P = .022), and greater reduction in fear of recurrence-related psychological distress (P = .017) compared with the SGI group. This study shows that an MGI combining support with cognitive-behavioral techniques and hypnosis is more effective than an SGI based only on support in improving anxiety regulation in patients with breast cancer. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Patient dose in CT fluoroscopy examinations

    International Nuclear Information System (INIS)

    Ito, Yusuke; Kobayashi, Masanao; Kataoka, Yumi; Ida, Yoshihiro; Kato, Ryoichi; Katada, Kazuhiro; Asada, Yasuki; Suzuki, Shoichi

    2008-01-01

    CT fluoroscopy(CTF) results in a high dose for the area under investigation in comparison with other types of examination. On the basis of data from April 2005 to March 2008, we measured the X-ray doses at the target site in CTF of the lungs, lumbar vertebrae, and pelvis as well as the X-ray dose to the female reproductive organs, and calculated the effective dose. The CT equipment used was an Aquilion 16. TLDs were inserted into an anthropomorphic phantom in positions corresponding to the target sites and the reproductive organs. Standard tube voltage and tube current were used as measurement conditions, and the scanning time used was the average value for each type of examination during the two years. Dose measurements were taken in the following order: scanography, helical scan, CTF, helical scan. X-ray element calibration was carried out through reciprocal comparison made between an ionization chamber dosimeter corrected according to government standards and the TLD for each tube voltage used for measurement. Dose estimation software was used to calculate the effective doses. During the two years there were 136 CTF examinations. These included 43 scans of the lungs, 13 of lumbar vertebrae, and 18 of the pelvis. The X-ray doses were 0.1 mGy at both the ovaries and the uterus for lung scans, 2 mGy at the ovaries and 1 mGy at the uterus for lumbar vertebrae scans, and 40 mGy at the ovaries and 20 mGy at the uterus for pelvic scans. The effective dose was highest for the lumbar vertebrae, followed by the lungs and finally the pelvis. (author)

  12. Attainment of dosimetric pediatrics grandeur to computed tomography examinations of the abdomen

    International Nuclear Information System (INIS)

    Jormada, Tiago S.

    2013-01-01

    Currently, 10% of all computerized tomography exams (CT) are made in pediatric patients. In developed countries, the practice of obtaining the dosimetric quantities (weighted index dose C w , index air kerma volumetric C vol product kerma-length P KL , CT ) and effective dose (E) in pediatric CT scans is common. In Brazil, data like these are practically nonexistent. The goal of this work is to obtain the dosimetric quantities and the dose effective in pediatric CT scans, and study its application in the optimization process. The study took place in a thermographs' Toshiba Asteion Single-Slice and a GE Brightsped's multi-slice where measurements were made with type pencil ionization chamber and a trunk's phantom of PMMA with diameter of 16 cm. In single-slice CT scanner, the results obtained for the C vol , P KL , CT and E were 18.73 mGy, 15.61 mGy and 6.87 mSv mGy.cm 343.51, respectively, whereas in multi-slice CT scanner the results were 18.81 mGy, 20.07 mGy, 441.64 mGy.cm and 8,83 mSv. There was no significant difference between the values of C w obtained already in the values of the Cvol, P KL , CT and E dose the differences between the results were quite significant. Comparing the C w and P KL , CT and with the values recommended by UCRP 87 (25 mGy for C vol and 360 mGy.cm for P KL , CT in pediatric CT scans of the abdomen), the two scanners were below reference levels for C w and not require an start on process of optimization. (author)

  13. The effects of rat's sperm bioassay for low dose X-ray

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gye Hwan; Min, Soo Young; Lee, Sang Bock; Lee, Sam Yul; Lee, Jun Haeng [Nambu Univ., Gwangju (Korea, Republic of); Park, Jong Bae [Juseong College, Cheongwon (Korea, Republic of)

    2007-12-15

    In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley (SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group. All the groups showed slightly increasing number of sperms per 0.1 g semen (14.216 x 10{sup 6}, 13.901 x 10{sup 6}, 14.153 x 10{sup 6}, 13.831 x 10{sup 6}, 14.137 x 10{sup 6}, 14.677 x 10{sup 6} respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body.

  14. Diagnostic accuracy at several reduced radiation dose levels for CT imaging in the diagnosis of appendicitis

    Science.gov (United States)

    Zhang, Di; Khatonabadi, Maryam; Kim, Hyun; Jude, Matilda; Zaragoza, Edward; Lee, Margaret; Patel, Maitraya; Poon, Cheryce; Douek, Michael; Andrews-Tang, Denise; Doepke, Laura; McNitt-Gray, Shawn; Cagnon, Chris; DeMarco, John; McNitt-Gray, Michael

    2012-03-01

    Purpose: While several studies have investigated the tradeoffs between radiation dose and image quality (noise) in CT imaging, the purpose of this study was to take this analysis a step further by investigating the tradeoffs between patient radiation dose (including organ dose) and diagnostic accuracy in diagnosis of appendicitis using CT. Methods: This study was IRB approved and utilized data from 20 patients who underwent clinical CT exams for indications of appendicitis. Medical record review established true diagnosis of appendicitis, with 10 positives and 10 negatives. A validated software tool used raw projection data from each scan to create simulated images at lower dose levels (70%, 50%, 30%, 20% of original). An observer study was performed with 6 radiologists reviewing each case at each dose level in random order over several sessions. Readers assessed image quality and provided confidence in their diagnosis of appendicitis, each on a 5 point scale. Liver doses at each case and each dose level were estimated using Monte Carlo simulation based methods. Results: Overall diagnostic accuracy varies across dose levels: 92%, 93%, 91%, 90% and 90% across the 100%, 70%, 50%, 30% and 20% dose levels respectively. And it is 93%, 95%, 88%, 90% and 90% across the 13.5-22mGy, 9.6-13.5mGy, 6.4-9.6mGy, 4-6.4mGy, and 2-4mGy liver dose ranges respectively. Only 4 out of 600 observations were rated "unacceptable" for image quality. Conclusion: The results from this pilot study indicate that the diagnostic accuracy does not change dramatically even at significantly reduced radiation dose.

  15. Hula Black - Eesti haute couture / Maria Ulfsak

    Index Scriptorium Estoniae

    Ulfsak, Maria, 1981-

    2003-01-01

    Esitleti uut Hula noortekomplekti Black, mille autorid on Anu Lensmant, Marit Ahven, Reet Ulfsak, Eve Hanson, Ruta Tepp, Ketlin Bachmann ja ehtekunstnikud Andrus Rumm, Julia-Maria Pihlak, Tanel Veenre

  16. Selgusi selle aasta parimad sportlased / Ketlin Bejaev

    Index Scriptorium Estoniae

    Bejaev, Ketlin

    2006-01-01

    Tartu tänavune parim meessportlane on karate maailmameister Marko Luhamaa, tema treener Jüri Post pälvis aasta treeneri tiitli. Parimaks naissportlaseks tunnistati laskeorienteerumise maailmameister Eveli Saue

  17. The Impact of Low Level X-rays on Biosynthesis of Gold Nanoparticles by Actinobacteria

    Directory of Open Access Journals (Sweden)

    Faranak Saghatchi

    2016-12-01

    Full Text Available Background: Gold nanoparticles (GNPs play an important role in medical, health and environmental applications. All kinds of microorganisms were found to be able to synthesize GNPs. The optimization of laboratory conditions for achieving more economical benefits of mass production has been studied widely. Methods: This study assesses the enhancing effect of low-level X-rays on the biosynthesis of GNPs by Actinomycetals. The isolated Actinomycetes were grown aerobically in MGYP broth media. The harvested bacteria were suspended in 50 mL aqueous HAuCl4 in 12 Erlenmeyer flask. Each group contained4 flasks. 2 groups of samples were irradiated by 30 mGy and 5 mGy X-rays respectively. The third group as control remained without irradiation. The solutions were shake- incubated for 120 h. Results: After 5 days, the color of first group samples changed from milky to purple, while the color changing occurred after 10 days in the 2nd group samples and the control samples. The UV-vis absorption spectrometry of the irradiated aqueous medium by 30 mGy X-rays confirmed the formation of GNPs. Conclusion: The findings showed that 30 mGy X-rays stimulated the microorganism to form GNPs in a half time in comparison to other groups.

  18. Study of an optimization protocol for radiographic techniques in computerized radiology; Estudo de um protocolo de otimizacao para as tecnicas radiograficas em radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Marcos Eugenio Silva

    2015-07-01

    This work is designed to produce information for the improvement of image quality to deployment in a radiology department based on previous reviews of the images by questionnaires of acceptance and quality e recognition of the parameters used in chest radiographic techniques. The data collected were divided by male, female, PA and LAT thickness, body mass index, biotypes, anthropomorphic parameters and body evaluation associated with constant voltage and the additional filtration. The results show the predominance of 35 and 40 constants with additional filtration from 0.5 to 1.5 mmAl, voltage in male: (PA and LAT) 86-92 kV and 96-112 kV, female: 85-98 kV and 96-112 kV. The charge applied to the tube for males: (PA and LAT) 5-10 mA.s and 5-16 mA.s, female: (PA and LAT) 6.3-8 mA.s and 9-14 mA.s. Absorbed doses for males: (PA and PF) 0.04-0.17 mGy and 0.03-0.19 mGy and from female (PA and PF) from 0.03-0.22 mGy and 0, 04-0.17 mGy. This procedure can be used in radiology department to implement and acceptance in the quality of images. (author)

  19. Immobilization of cellulose producing cells (sporotrichum cellulophilum) using irradiated rice husk as a substrate

    International Nuclear Information System (INIS)

    Lina, M.R.; Tamada, M.; Kumakura, M.

    1991-01-01

    An experiment to study the effect of irradiated rice husk as a substrate on cellulase production of free and immobilized cells of S. cellulophium was carried out. Radiation pretreatment of rice husk was done using electron beam accelerator (Dynamitron IEA 3000-25,2), with doses of 0, 0.2, 0.4, 0.6, 0.8, and 1.0 MGy. The substrate used in cellulase production of free and immobilized cells were cellulose powder as a standard, and 1.0 MGy irradiated rice husk. Concentrations of cellulose powder for free and immobilized cells were 1, 2, 3, 5, and 8% (w/v). Irradiated rice husk concentrations for free cells were 3, 6, 9, 15, and 24% (w/v), whereas for immobilized cells were 3, 6, and 9% (w/v). Results showed that glucose concentration in 1.0 MGy irradiated rice husk was the highest of all irradiated and unirradiated rice husks. The GPA (glucose production activity) values used of free immobilized cells of S. cellulophium in medium containing 1.0 MGy irradiated rice husk were about 50% lower than in cellulose powder medium. Cellulase solution resulted by immobilized cells, either in cellulose powder or in irradiated rice husk media, were clear and did not contain mycelium. (authors). 7 refs, 7 figs

  20. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Spadavecchia, Chiara [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Veronese, Ivan [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Cantone, Marie Claire [Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Milano (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Department of Biomedical Science for Health, San Donato Milanese (Italy)

    2017-07-15

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  1. The rate of X-ray-induced DNA double-strand break repair in the embryonic mouse brain is unaffected by exposure to 50 Hz magnetic fields.

    Science.gov (United States)

    Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2015-06-01

    Following in utero exposure to low dose radiation (10-200 mGy), we recently observed a linear induction of DNA double-strand breaks (DSB) and activation of apoptosis in the embryonic neuronal stem/progenitor cell compartment. No significant induction of DSB or apoptosis was observed following exposure to magnetic fields (MF). In the present study, we exploited this in vivo system to examine whether exposure to MF before and after exposure to 100 mGy X-rays impacts upon DSB repair rates. 53BP1 foci were quantified following combined exposure to radiation and MF in the embryonic neuronal stem/progenitor cell compartment. Embryos were exposed in utero to 50 Hz MF at 300 μT for 3 h before and up to 9 h after exposure to 100 mGy X-rays. Controls included embryos exposed to MF or X-rays alone plus sham exposures. Exposure to MF before and after 100 mGy X-rays did not impact upon the rate of DSB repair in the embryonic neuronal stem cell compartment compared to repair rates following radiation exposure alone. We conclude that in this sensitive system MF do not exert any significant level of DNA damage and do not impede the repair of X-ray induced damage.

  2. Radiation doses to children with shunt-treated hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Holmedal, Lise J. [Helse Fonna, Department of Radiology, Stord Hospital, Stord (Norway); Friberg, Eva G.; Boerretzen, Ingelin; Olerud, Hilde [The Norwegian Radiation Protection Authority, Oesteraas (Norway); Laegreid, Liv [Haukeland University Hospital, Department of Paediatrics, Bergen (Norway); Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Radiology Section, Bergen (Norway); Great Ormond Street Hospital for Children, Department of Diagnostic Radiology, London (United Kingdom)

    2007-12-15

    Children with shunt-treated hydrocephalus are still followed routinely with frequent head CT scans. To estimate the effective dose, brain and lens doses from these examinations during childhood, and to assess dose variation per examination. All children born between 1983 and 1995 and treated for hydrocephalus between 1983 and 2002 were included. We retrospectively registered the number of examinations and the applied scan parameters. The effective dose was calculated using mean conversion factors from the CT dose index measured free in air, while doses to the lens and brain were estimated using tabulated CT dose index values measured in a head phantom. A total of 687 CT examinations were performed in 67 children. The mean effective dose, lens dose and brain dose to children over 6 months of age were 1.2 mSv, 52 mGy and 33 mGy, respectively, and the corresponding doses to younger children were 3.2 mSv, 60 mGy and 48 mGy. The effective dose per CT examination varied by a factor of 64. None of the children was exposed to doses known to cause deterministic effects. However, since the threshold for radiation-induced damage is not known with certainty, alternative modalities such as US and MRI should be used whenever possible. (orig.)

  3. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco; Spadavecchia, Chiara; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-01-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  4. Radiation doses from mammography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Young, B.F.; Young, J.G.; Tingey, D.R.C.

    1991-05-01

    During 1989-90 the Australian Radiation Laboratory conducted a postal survey of at least 90% of the mammographic facilities in Australia. The primary aim of the survey was to measure the mean glandular dose (MGD) and the X-ray beam half value layer (HVL) for a typical mammograph. The MGD and HVL were measured with a specially designed tissue equivalent monitor. In all, 258 mammographic centres were surveyed. It was found that for centres using film-screen imaging, the average mean glandular dose was 1.83 mGy for centres using grids and 0.84 mGy for centres not using grids. In addition to the MGD and HVL, comprehensive statistical information was collected and data is presented on the types of equipment and techniques used, the number and age of patients and demographic distribution of centres. Results indicate that the use of a grid is the major factor determining dose and several other factors appear to have minor effects. In view of the distribution of MGD, it is recommended that the mean glandular dose per image, for a 5 cm compressed breast thickness, should not exceed 2.0 mGy when a grid is used and 1.0 mGy without a grid. 63 refs., 11 tabs., 15 figs

  5. Study of an optimization protocol for radiographic techniques in computerized radiology

    International Nuclear Information System (INIS)

    Abrantes, Marcos Eugenio Silva

    2015-01-01

    This work is designed to produce information for the improvement of image quality to deployment in a radiology department based on previous reviews of the images by questionnaires of acceptance and quality e recognition of the parameters used in chest radiographic techniques. The data collected were divided by male, female, PA and LAT thickness, body mass index, biotypes, anthropomorphic parameters and body evaluation associated with constant voltage and the additional filtration. The results show the predominance of 35 and 40 constants with additional filtration from 0.5 to 1.5 mmAl, voltage in male: (PA and LAT) 86-92 kV and 96-112 kV, female: 85-98 kV and 96-112 kV. The charge applied to the tube for males: (PA and LAT) 5-10 mA.s and 5-16 mA.s, female: (PA and LAT) 6.3-8 mA.s and 9-14 mA.s. Absorbed doses for males: (PA and PF) 0.04-0.17 mGy and 0.03-0.19 mGy and from female (PA and PF) from 0.03-0.22 mGy and 0, 04-0.17 mGy. This procedure can be used in radiology department to implement and acceptance in the quality of images. (author)

  6. Radiation risk to the patient: a case study involving multiple diagnostic X ray exposures given over a period of 25 years

    International Nuclear Information System (INIS)

    Rainbow, A.J.; McMaster Univ., Hamilton, ON; Roginski, P.; McGeen, W.

    1992-01-01

    The cumulative somatic dose index (SDI) for a number of diagnostic X ray examinations was made for a 60 year old male. The history of diagnostic X ray exposure for this patient from 1957 to 1983 showed 29 diagnostic X ray examinations including more than 100 films and 15 minutes of fluoroscopy. The total cumulative SDI to this patient was 214 mGy (about 21 rad). More than half this dose, 142 mGy, was contributed from upper GI and barium enema examinations which used fluoroscopy, with 88 mGy from the fluoroscopy alone. Using the recently revised risk coefficient for fatal cancer following whole-body irradiation of adult workers recommended by the International Commission on Radiological Protection in 1990, the authors estimate a 0.9% cancer morality risk to this patient resulting from the 29 diagnostic X ray examinations. (author)

  7. Materials Genome Initiative

    Science.gov (United States)

    Vickers, John

    2015-01-01

    The Materials Genome Initiative (MGI) project element is a cross-Center effort that is focused on the integration of computational tools to simulate manufacturing processes and materials behavior. These computational simulations will be utilized to gain understanding of processes and materials behavior to accelerate process development and certification to more efficiently integrate new materials in existing NASA projects and to lead to the design of new materials for improved performance. This NASA effort looks to collaborate with efforts at other government agencies and universities working under the national MGI. MGI plans to develop integrated computational/experimental/ processing methodologies for accelerating discovery and insertion of materials to satisfy NASA's unique mission demands. The challenges include validated design tools that incorporate materials properties, processes, and design requirements; and materials process control to rapidly mature emerging manufacturing methods and develop certified manufacturing processes

  8. Tallinnas võistlevad üheminutifilmid

    Index Scriptorium Estoniae

    2001-01-01

    Tallinnas toimuvad täna UNICA 63. ülemaailmse amatöörfilmide festivali raames üheminutiliste filmide maailmameistrivõistlused. Eestit esindab Tõnu Aru ja Eve Esteri film "Friendly" ("Sõbralikult")

  9. Moskovskije oligarhi predpotshitajut / Tatjana Tridvornova ; interv. Marina Poltavtseva

    Index Scriptorium Estoniae

    Tridvornova, Tatjana

    2005-01-01

    Lilleballi ja Lillekleidi konkursi autori Tatjana Tridvornovaga tema tööst Moskvas. Avas Moskvas kunstistuudio Flowers Vasari. Tema abilisteks on eesti lilleseadjad Heiti Põder, Ahti Lyra ja Eve Aben

  10. Bridging the Gap: Linking Simulation and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Krajewski, Paul E.; Carsley, John; Stoudt, Mark R.; Hovanski, Yuri

    2012-09-01

    The Materials Genome Initiative (MGI) which is a key enabler for the Advanced Manufacturing Partnership, announced in 2011 by U.S. President Barack Obama, was established to accelerate the development and deployment of advanced materials. The MGI is driven by the need to "bridge the gap" between (I) experimental results and computational analysis to enable the rapid development and validation of new mateirals, and (II) the processes required to convert these materials into useable goods.

  11. Summer Camp July 2017 - Registration

    CERN Multimedia

    EVE et École

    2017-01-01

    The CERN Staff Association’s Summer Camp will be open for children from 4 to 6 years old during four weeks, from 3 to 28 July. Registration is offered on a weekly basis for 450 CHF, lunch included. This year, the various activities will revolve around the theme of the Four Elements. Registration opened on 20 March 2017 for children currently attending the EVE and School of the Association. It will be open from 3 April for children of CERN Members of Personnel, and starting from 24 April for all other children. The general conditions are available on the website of the EVE and School of CERN Staff Association: http://nurseryschool.web.cern.ch. For further questions, please contact us by email at Summer.Camp@cern.ch.

  12. Eesti graafikud Krakówi triennaalil

    Index Scriptorium Estoniae

    2009-01-01

    16. septembril Poolas avatud Krakówi rahvusvahelise graafikatriennaali peanäitusel ja satelliitnäitustel esindavad Eestit Eve Kask, Ülle Marks, Benjamin Vasserman, Tiiu Prisko, Mati Veermets, Evi Tihemets

  13. STUDY OF THE SEDIMENTATION TREND IN THE PROSPECTIVE AREA OF PORT OF MARINE CENTER, CIREBON BASED ON REMOTE SENSING DATA

    Directory of Open Access Journals (Sweden)

    Undang Hernawan

    2017-07-01

    Full Text Available A coastal zone is the interface between the land and water that influenced by both of them. Coastal dynamic is influenced by many factors from land and sea, such as sedimentation and current. In order to support marine facility, Marine Geological Institute of Indonesia (MGI plan to build a port. The prospective area is behind MGI office at Cirebon. This study use multi temporal remote sensing data in order to observe trend of coastline change around MGI. Based on the interpretation of the data, there are sedimentation around the MGI water and abrasion due to the presence of Kejawanan’s jetty and Kalijaga River. The result also shows that the current in this region is moving from southeast to northwest. The presence of the Kejawanan’s jetty stymies the movement of sediment. The sediment which is normally moving to the north of the jetty is then trapped on the south side of the structure, so that the sediment precipitates in this region and makes it as the active region of sedimentation and accretion. The presence mangrove conduces to support sedimentation speed and accretion at this region, because of his function as the catchment area. Abrasion occurs in the eastern part of MGI office at the Kalijaga river mouth within the bay. The Kalijaga River mouth is predicted to be the primary source of sedimentation in this area. The coastline change caused by sedimentation will be continuing as long as it is supplied by the sediment. The direction of the sedimentation is parallel to the jetty and it forms ellipsoid, with the sedimentation/accretion region is behind MGI office. The abrasion area is found in Kalijaga River mouth and a small area beside Kalijaga River. In order to build a port, we have to consider this sedimentation process. One of the alternatives to build the port is to make a quay pile model which gives way the current to pass through the other side of the port. Another alternative is to build the port as a pond model but

  14. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  15. WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Dodge, C.T.; Rong, J. [MD Anderson Cancer Center, Houston, TX (United States); Dodge, C.W. [Methodist Hospital, Houston, TX (United States)

    2014-06-15

    Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary.

  16. External dose reconstruction in tooth enamel of Techa riverside residents

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A.; Volchkova, A.Yu.; Krivoschapov, V.A.; Degteva, M.O. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation); Timofeev, Y.S.; Zalyapin, V.I. [Southern Urals State University, Chelyabinsk (Russian Federation); Fattibene, P.; Della Monaca, S.; De Coste, V. [Istituto Superiore di Sanita e Istituto Nazionale di Fisica Nucleare, Rome (Italy); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, Neuherberg (Germany); Ivanov, D.V. [M.N. Mikheev Institute of Metal Physics, Ural Division of the Russian Academy of Sciences, Ekaterinburg (Russian Federation); Ural Federal University, Yekaterinburg (Russian Federation); Anspaugh, L.R. [University of Utah, Salt Lake City, UT (United States)

    2016-11-15

    This study summarizes the 20-year efforts for dose reconstruction in tooth enamel of the Techa riverside residents exposed to ionizing radiation as a result of radionuclide releases into the river in 1949-1956. It represents the first combined analysis of all the data available on EPR dosimetry with teeth of permanent residents of the Techa riverside territory. Results of electron paramagnetic resonance (EPR) measurements of 302 teeth donated by 173 individuals living permanently in Techa riverside settlements over the period of 1950-1952 were analyzed. These people were residents of villages located at the free-flowing river stream or at the banks of stagnant reservoirs such as ponds or blind river forks. Cumulative absorbed doses measured using EPR are from several sources of exposure, viz., background radiation, internal exposure due to bone-seeking radionuclides ({sup 89}Sr, {sup 90}Sr/{sup 90}Y), internal exposure due to {sup 137}Cs/{sup 137m}Ba incorporated in soft tissues, and anthropogenic external exposure. The purpose of the present study was to evaluate the contribution of different sources of enamel exposure and to deduce external doses to be used for validation of the Techa River Dosimetry System (TRDS). Since various EPR methods were used, harmonization of these methods was critical. Overall, the mean cumulative background dose was found to be 63 ± 47 mGy; cumulative internal doses due to {sup 89}Sr and {sup 90}Sr/{sup 90}Y were within the range of 10-110 mGy; cumulative internal doses due to {sup 137}Cs/{sup 137m}Ba depend on the distance from the site of releases and varied from 1 mGy up to 90 mGy; mean external doses were maximum for settlements located at the banks of stagnant reservoirs (∝500 mGy); in contrast, external doses for settlements located along the free-flowing river stream did not exceed 160 mGy and decreased downstream with increasing distance from the site of release. External enamel doses calculated using the TRDS code and

  17. Comparative proteomic analysis of rice after seed ground simulated radiation and spaceflight explains the radiation effects of space environment

    Science.gov (United States)

    Wang, Wei; Shi, Jinming; Liang, Shujian; Lei, Huang; Shenyi, Zhang; Sun, Yeqing

    In previous work, we compared the proteomic profiles of rice plants growing after seed space-flights with ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) and found that the protein expression profiles were changed after seed space environment exposures. Spaceflight represents a complex environmental condition in which several interacting factors such as cosmic radiation, microgravity and space magnetic fields are involved. Rice seed is in the process of dormant of plant development, showing high resistance against stresses, so the highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to seeds. To further investigate the radiation effects of space environment, we performed on-ground simulated HZE particle radiation and compared between the proteomes of seed irra-diated plants and seed spaceflight (20th recoverable satellite) plants from the same rice variety. Space ionization shows low-dose but high energy particle effects, for searching the particle effects, ground radiations with the same low-dose (2mGy) but different liner energy transfer (LET) values (13.3KeV/µm-C, 30KeV/µm-C, 31KeV/µm-Ne, 62.2KeV/µm-C, 500Kev/µm-Fe) were performed; using 2-D DIGE coupled with clustering and principle component analysis (PCA) for data process and comparison, we found that the holistic protein expression patterns of plants irradiated by LET-62.2KeV/µm carbon particles were most similar to spaceflight. In addition, although space environment presents a low-dose radiation (0.177 mGy/day on the satellite), the equivalent simulated radiation dose effects should still be evaluated: radiations of LET-62.2KeV/µm carbon particles with different cumulative doses (2mGy, 20mGy, 200mGy, 2000mGy) were further carried out and resulted that the 2mGy radiation still shared most similar proteomic profiles with spaceflight, confirming the low-dose effects of space radiation. Therefore, in the protein expression level

  18. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    International Nuclear Information System (INIS)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques; Santangelo, Teresa; Duhamel, Alain; Deschildre, Antoine

    2017-01-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol 32 ) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP 32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP 32 , CTDI vol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP 32 , 0.78-1.25 mGy for the CTDI vol32 and 1.6-2.1 mGy for the SSDE. (orig.)

  19. WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

    International Nuclear Information System (INIS)

    Dodge, C.T.; Rong, J.; Dodge, C.W.

    2014-01-01

    Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary

  20. Oliivipuude triloogia - mõnus suvine võrkkiige-lugemine / Mari Klein

    Index Scriptorium Estoniae

    Klein, Mari

    2007-01-01

    Tutvustus: Drinkwater, Carol. Oliiviistandus / tlk. Laine Hone. Tallinn : Varrak, 2004 ; Drinkwater, Carol. Oliivisaak / tlk. Eve-Reet Tammet. Tallinn : Varrak, 2997 ; Drinkwater, Carol. Oliivihooaeg / tlk. Lane Hone ja Karin Rita. Tallinn : Varrak, 2006

  1. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  2. Combined effects of alpha particles and depleted uranium on Zebrafish (Danio rerio) embryos

    International Nuclear Information System (INIS)

    Ng, Candy Y.P.; Pereira, Sandrine; Cheng, Shuk Han; Adam-Guillermin, Christelle; Garnier-Laplace, Jacqueline; Yu, Kwan Ngok

    2016-01-01

    The combined effects of low-dose or high-dose alpha particles and depleted uranium (DU) in Zebrafish (Danio rerio) embryos were studied. Three schemes were examined—(i) [I L U L ]: 0.44 mGy alpha-particle dose + 10 µg/l DU exposure, (ii) [I H U H ]: 4.4 mGy alpha-particle dose + 100 µg/l DU exposure and (iii) [I H U L ]: 4.4 mGy alpha-particle dose + 10 µg/l DU exposure—in which Zebrafish embryos were irradiated with alpha particles at 5 h post fertilization (hpf) and/or exposed to uranium at 5–6 hpf. The results were also compared with our previous work, which studied the effects of [I L U H ]: 0.44 mGy alpha-particle dose + 100 µg/l DU exposure. When the Zebrafish embryos developed to 24 hpf, the apoptotic signals in the entire embryos, used as the biological endpoint for this study, were quantified. Our results showed that [I L U L ] and [I H U L ] led to antagonistic effects, whereas [I H U H ] led to an additive effect. The effect found for the previously studied case of [I L U H ] was difficult to define because it was synergistic with reference to the 100 µg/l DU exposure, but it was antagonistic with reference to the 0.44 mGy alpha-particle dose. All the findings regarding the four different schemes showed that the combined effects critically depended on the dose response to each individual stressor. We also qualitatively explained these findings in terms of promotion of early death of cells predisposed to spontaneous transformation by alpha particles, interacting with the delay in cell death resulting from various concentrations of DU exposure

  3. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  4. Some experiences from radiation protection of patients undergoing X-ray examinations in Tanzania

    International Nuclear Information System (INIS)

    Ngaile, J.E.; Muhogora, W.E.; Nyanda, A.M.

    2001-01-01

    A study of patient entrance surface dose (ESD) received by adult patients was undertaken in five major diagnostic facilities in Tanzania. Five selected X-ray projections for chest PA; abdomen AP; lumbar spine AP; lumbar spine LAT and pelvis AP were done in the study. The mean ESDs after introduction of dose reduction methods were 0.34 mGy, 5.41 mGy, 3.7 mGy, 4.8 mGy and 8.8 mGy for chest PA; abdomen AP; pelvis AP; lumbar spine AP and lumbar spine LAT, respectively. The variations of doses observed in the study were influenced by performance characteristic of X-ray equipment, patient shape and size, type of image receptor, radiographic techniques as well as skills employed. The results show that increasing the tube voltage reduced the ESD by 35.5%, while lowering of mAs reduced ESD in the range from 15% to 60%. The reduction of ESD by increasing the filtration ranged from 11% to 58% while increasing of speed class of film-screen combination reduced the ESD in the range from 33% to 57%. The corresponding results of image quality show that out of 1064 scores of image criteria 298,481 and 285 were rated for good, satisfactory and poor respectively. The results of this study provide an evidence of existing potential for dose reduction in the diagnostic radiology facilities and the most important factor for improvement is to increase awareness, both from reality of harm from unnecessary radiation exposure and with relative ease doses can be reduced. The study should therefore be implemented on the national scale as an approach to establish guidance levels of patient entrance surface dose for good medical practice and regular monitoring purposes. (author)

  5. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Yang, K; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

  6. Evaluation of thyroid function in female subjects living in the high natural background radiation area of Karunagappally, Kerala

    International Nuclear Information System (INIS)

    Sreekumar, A.; Nair, Raghu Ram K.; Jayalakshmi, P.; Sebastian, P.; Akiba, S.

    2010-01-01

    Radiation exposure has been reported to cause non cancer thyroid abnormalities like diffuse goiter and thyroid nodules. The present study was undertaken to see if there are any morphological and functional changes taking place in the thyroid due to chronic low level radiation exposure. 257 female subjects living in the four high background radiation panchayats of Chavara, Neendakara, Alappad and Panmana were selected for the study after getting informed consent. 5 ml of blood was drawn from these subjects for assessing thyroid function. The subjects were all staying in the same area since their birth and had not moved out for more than one year at a stretch. The average age of the subjects was 40.5y with a range of 17-66y. The cumulative dose had a mean of 226.3 mGy and a range of 20.6-937.8 mGy. 95 subjects from the low background area of Oachira and Thevalakkara were selected as controls in the age group of 18-63y with a mean age of 47.1y. The mean cumulative dose of this group was 35.9 mGy with a minimum of 5.3 mGy and a maximum of 106.8 mGy. 5 ml blood was collected from these subjects for thyroid function studies. All the subjects underwent ultrasound examination of the thyroid using a 10 MHz frequency linear probe. The following parameters were studied to assess thyroid function: Free T4, TSH, Antithyroglobulin antibody (ATG), Parathyroid hormone. Ultrasound images showed the following common features: Normal - 171, Suggestive of Thyroiditis - 106, Multinodular Goitre - 63, Diffuse Goitre - 5, Solitary Nodule - 31. 73 subjects had elevated TSH and 190 subjects had raised ATG. A significant numbers of subjects had features of thyroiditis. A comparative evaluation with control subjects will be done to assess its significance with reference to cumulative dose

  7. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  8. Contextualising sexual harassment of adolescent girls in Bangladesh.

    Science.gov (United States)

    Nahar, Papreen; van Reeuwijk, Miranda; Reis, Ria

    2013-05-01

    Violence against women is a social mechanism confirming women's subordination in many societies. Sexual violence and harassment have various negative psychological impacts on girls, including a persistent feeling of insecurity and loss of self-esteem. This article aims to contextualize a particular form of sexual harassment, namely "eve teasing", experienced by Bangladeshi adolescent girls (12-18 years) which emerged from a study of adolescent sexual behaviour carried out by young people. The study used qualitative methods and a participatory approach, including focus group discussions, key informant interviews and observation. Despite taboos, unmarried adolescents actively seek information about sex, erotic pleasure and romance. Information was easily available from videos, mobile phone clips and pornographic magazines, but reinforced gender inequality. "Eve teasing" was one outlet for boys' sexual feelings; they gained pleasure from it and could show their masculinity. The girls disliked it and were afraid of being blamed for provoking it. Thus, "eve teasing" is a result of socio-cultural norms relating to sexuality, as well as a lack of access to sexual and reproductive health information and services in Bangladesh. These findings underscore the importance of comprehensive sexuality education that goes beyond a mere health focus and addresses gender norms and helps youth to gain social-sexual interaction skills. Copyright © 2013 Reproductive Health Matters. Published by Elsevier Ltd. All rights reserved.

  9. Rhabdovirus-like endogenous viral elements in the genome of Spodoptera frugiperda insect cells are actively transcribed: Implications for adventitious virus detection.

    Science.gov (United States)

    Geisler, Christoph; Jarvis, Donald L

    2016-07-01

    Spodoptera frugiperda (Sf) cell lines are used to produce several biologicals for human and veterinary use. Recently, it was discovered that all tested Sf cell lines are persistently infected with Sf-rhabdovirus, a novel rhabdovirus. As part of an effort to search for other adventitious viruses, we searched the Sf cell genome and transcriptome for sequences related to Sf-rhabdovirus. To our surprise, we found intact Sf-rhabdovirus N- and P-like ORFs, and partial Sf-rhabdovirus G- and L-like ORFs. The transcribed and genomic sequences matched, indicating the transcripts were derived from the genomic sequences. These appear to be endogenous viral elements (EVEs), which result from the integration of partial viral genetic material into the host cell genome. It is theoretically impossible for the Sf-rhabdovirus-like EVEs to produce infectious virus particles as 1) they are disseminated across 4 genomic loci, 2) the G and L ORFs are incomplete, and 3) the M ORF is missing. Our finding of transcribed virus-like sequences in Sf cells underscores that MPS-based searches for adventitious viruses in cell substrates used to manufacture biologics should take into account both genomic and transcribed sequences to facilitate the identification of transcribed EVE's, and to avoid false positive detection of replication-competent adventitious viruses. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  10. Electron probe X-ray microanalysis of boar and inobuta testes after the Fukushima accident

    International Nuclear Information System (INIS)

    Yamashiro, Hideaki; Abe, Yasuyuki; Hayashi, Gohei; Urushihara, Yusuke; Kuwahara, Yoshikazu; Suzuki, Masatoshi; Kobayashi, Jin; Kino, Yasuyuki; Fukuda, Tomokazu; Tong, Bin; Takino, Sachio; Sugano, Yukou; Sugimura, Satoshi; Yamada, Takahisa; Isogai, Emiko; Fukumoto, Manabu

    2015-01-01

    We aimed to investigate the effect of chronic radiation exposure associated with the Fukushima Daiichi Nuclear Power Plant (FNPP) accident on the testes of boar and inobuta (a hybrid of Sus scrofa and Sus scrofa domestica). This study examined the contamination levels of radioactive caesium (Cs), especially 134 Cs and 137 Cs, in the testis of both boar and inobuta during 2012, after the Fukushima accident. Morphological analysis and electron-probe X-ray microanalysis (EPMA) were also undertaken on the testes. The 134 Cs and 137 Cs levels were 6430 ± 23 and 6820 ± 32 Bq/kg in the boar testes, and 755 ± 13 and 747 ± 17 Bq/kg in the inobuta testes, respectively. The internal and external exposure of total 134 Cs and 137 Cs in the boar testes were 47.1 mGy and 176.2 mGy, respectively, whereas in the inobuta testes, these levels were 6.09 mGy and 59.8 mGy, respectively. Defective spermatogenesis was not detected by the histochemical analysis of radiation-exposed testes for either animal. In neither animal were Cs molecules detected, using EPMA. In conclusion, we showed that adverse radiation-induced effects were not detected in the examined boar and inobuta testes following the chronic radiation exposure associated with the FNPP accident

  11. Pilot survey of patient dose from computed tomography in Bulgaria

    International Nuclear Information System (INIS)

    Vassileva, Jenia; Stoyanov, Desislav

    2008-01-01

    The number of computed tomography (CT) scanners in Bulgaria increased from 22 in 1996 to more than 160 in 2007. Big variety of scanners of different manufacturers and different generations exists in the country with predominant number of single-slice scanners. Significant part of the scanners is more than 10 years old. This work presents the pilot results from the measurements of CT dose quantities started in 2005 with the aim to spread them to a national survey of CT practice in the country. It was found that different clinical protocols are used for similar examination, resulting in large variations in dose quantities: CT air kerma index varied from 27.1 to 78.4 mGy for head examination, from 8.7 to 28.3 mGy for chest, 11.8 - 30.7 mGy for abdomen and 9.1 - 41.3 mGy for pelvis. The CT air kerma-length product for complete examination was found to vary from 310 to 1254 mGy.cm for head examination, from 215 to 893 mGy.cm for chest, from 265 to 615 mGy.cm for abdomen and from 220 to 761 mGy.cm for pelvis. The analysis demonstrated that the main reasons for found variations are differences in scanning geometry, beam quality, exposure parameters and scanning length. (author)

  12. Evaluation of doses in conventional radiology in the cities of Rio de Janeiro e Recife, Brazil

    International Nuclear Information System (INIS)

    Azevedo, Ana Cecilia P.; Osibote, Adelaja O.; Khoury, Helen J.

    2005-01-01

    This work is part of a program of evaluating doses in patients developed in several hospitals in the States of Rio de Janeiro and Pernambuco. We used the program DoseCal to evaluate the Input Skin Dose (DEP) and the Effective Dose (DE) in big public hospitals in the cities of Rio de Janeiro and Recife. It were included in the survey the doses of chest radiographs, cervical spine, lumbar spine, skull and pelvis in the projections AP, PA and LAT. To chest in PA the average value of DEP for the hospital A was 0.19 mGy. For to hospital B was 0.07 mGy. For the exam of the skull in PA the average value in A was 3.25 mGy and B of 0.49 mGy. With respect to radiological techniques might be noted that in most cases the hospital A used kilovoltage lower than in B and miliamperes higher. This can be one of the explanations for the difference of the values found for DEP and DE. The results showed significant discrepancies in values of doses as radiographic techniques when compared to the requirements established by the European Community for X-rays with image quality. This result is due to several factors: filtration, radiographic technique, professional technical experience and performance of radiographic equipment

  13. Radiation dose with digital breast tomosynthesis compared to digital mammography. Per-view analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gennaro, Gisella [Veneto Institute of Oncology IOV- IRCCS, Radiology Unit, Padua (Italy); Bernardi, D. [Azienda Provinciale Servizi Sanitari (APSS), U.O. Senologia Clinica e Screening Mammografico, Department of Diagnostics, Trento (Italy); Houssami, N. [University of Sydney, Screening and Test Evaluation Program (STEP), School of Public Health, Sydney Medical School, Sydney (Australia)

    2018-02-15

    To compare radiation dose delivered by digital mammography (FFDM) and breast tomosynthesis (DBT) for a single view. 4,780 FFDM and 4,798 DBT images from 1,208 women enrolled in a screening trial were used to ground dose comparison. Raw images were processed by an automatic software to determine volumetric breast density (VBD) and were used together with exposure data to compute the mean glandular dose (MGD) according to Dance's model. DBT and FFDM were compared in terms of operation of the automatic exposure control (AEC) and MGD level. Statistically significant differences were found between FFDM and DBT MGDs for all views (CC: MGD{sub FFDM}=1.366 mGy, MGD{sub DBT}=1.858 mGy; p<0.0001; MLO: MGD{sub FFDM}=1.374 mGy, MGD{sub DBT}=1.877 mGy; p<0.0001). Considering the 4,768 paired views, Bland-Altman analysis showed that the average increase of DBT dose compared to FFDM is 38 %, and a range between 0 % and 75 %. Our findings show a modest increase of radiation dose to the breast by tomosynthesis compared to FFDM. Given the emerging role of DBT, its use in conjunction with synthetic 2D images should not be deterred by concerns regarding radiation burden, and should draw on evidence of potential clinical benefit. (orig.)

  14. Ionizing radiations dosimetry: new results in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.

    1989-01-01

    Industrial irradiation for food preservation, medical sterilization and plastic processing is in great expansion and an accurate dosimetry in the megagray range is required. It is also required for safety purposes around nuclear reactors or waste storage sites. The study of photon-matter interaction leads us to consider high-dose dosimeters among the solids in which radiolysis occurs. Organic conductors are indeed good candidates for high-dose dosimetry. These materials show original properties due to the great anisotropy of their electronic system. Radiation effects, especially on the resistivity and on the (E.S.R.) Electron Spin Resonance linewidth, are very important. We show that a simple resistance measurement allows an accurate monitoring of the absorbed dose, in the range 0.01 - 50 MGy, for X-rays, gamma-rays and electron irradiations. The E.S.R. linewidth measurements permits the use of small dosimeters between 1 and 100 MGy. Finally, some organic conductors are proposed as high-temperature dosimeters for irradiation performed up to 120 0 C. The irradiated pure silica contains a large variety of defects. Only the E' center seems helpful for dosimetry purposes, and its electron spin resonance (E.S.R.) signal is simply related to the absorbed dose in the range 0.1 - 3 MGy or even, 0.5 kGy - 5 MGy [fr

  15. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  16. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  17. Crystal growth and thermoluminescence response of NaZr2(PO4)3 at high gamma radiation doses

    International Nuclear Information System (INIS)

    Ordóñez-Regil, E.; Contreras-Ramírez, A.; Fernández-Valverde, S.M.; González-Martínez, P.R.; Carrasco-Ábrego, H.

    2013-01-01

    Graphical abstract: -- Highlights: •NaZr 2 (PO 4 ) 3 exposed to gamma doses of 10, 30 and 50 MGy. •Gamma radiation produced growth of the crystal size of the NZP. •Morphology changes were reversible by heating. •Linear relationship between the thermoluminescence and the applied gamma dose. •This property could be useful for high-level gamma dosimetry. -- Abstract: This work describes the synthesis and characterization of NaZr 2 (PO 4 ) 3 . The stability of this material under high doses of gamma radiation was investigated in the range of 10–50 MGy. Samples of unaltered and gamma irradiated NaZr 2 (PO 4 ) 3 were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and thermoluminescence. The results showed that while functional groups were not affected by the gamma irradiation, morphology changes were observed with increasing doses of gamma irradiation. The morphology of the non-irradiated compound is agglomerated flakes; however, irradiation at 10 MGy splits the flakes inducing the formation of well-defined cubes. Gamma irradiation induced the crystal size of the NaZr 2 (PO 4 ) 3 to grow. The heat treatment (973 K) of samples irradiated at 50 MGy resulted in the recovery of the original morphology. Furthermore, the thermoluminescence analysis of the irradiated compound is reported

  18. SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B; Walz-Flannigan, A [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantom model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.

  19. ADEM – HAVVA – LİLİTH FİGÜRLERİ İZLEĞİNDE BİR OLANAKSIZLIK MİTİ: AŞK

    Directory of Open Access Journals (Sweden)

    Ender Ozbay

    2013-10-01

    Full Text Available "Love," the primary subject of art, also exhibits the characteristics of individual-social myth. The source of basic fact and concept of woman-man relationship to which "love" is related; the root and qualities of moral tradition and opinions can be seen from the "creation" narrations of holy books and various precepts. Some "creation" narration and myths tells about the creation of a woman named "Lilith" before Eve. In a creation story belonging to the 2000 BC, when she was first seen, Lilith, being the goddess of the matriarchal period and expelled from the patriarchal Sumerian world, is seen as an excluded character in the scripts of Cabala doctrines, too. In narrations and compositions, excluding the "powerful-subject" woman image from social life and rendering acceptable the woman identity which is dependent on a "power" composed of God-government-man, Lilith and Eve show mythological figure features symbolizing the opposite poles of woman identity and "morals. " In works of art performing the progressive events which come up with the persuasion of a living creature, which is the combination of snake-Devil-woman(Lilith in holy scripts, Eve about the "forbidden fruit", two characters are reflected with the imagery of contrasts representing hostility. In the descriptions of some works of art illustrating the art playing a part in the service of "gender ideology" and in modern digital-fantastic descriptions, a connection between the women and misdeed is made explicit with figures composed of snake-woman. Man gender of mankind building an ownership relation with the universe develops "dominance" in a more complicated way against its female and urged the woman to be either Lilith or Eve; and he was in the shadow of the unreal "power-strength" imagery. In the world shaped with "benefit values," "love," whose sides cannot be free-real subjects, has turned into an impossible myth, let alone being real.

  20. Professor Peep Veski meie meenutustes

    Index Scriptorium Estoniae

    2014-01-01

    Mälestusi Tartu Ülikooli Farmaatsia instituudi juhatajast Peep Veskist jagavad: Eve-Irene Lepist, Urve Paaver, Karin Kogermann, Kristian Semjonov, Jaak Koppel, Kristin Raudsepp, Imre Klebovich, Filiz Hincal, A. Atilla Hincal ja Elmar Arak

  1. Sotsiaalkapitali elemendid ja allikad / Eve Parts

    Index Scriptorium Estoniae

    Parts, Eve, 1970-

    2006-01-01

    Sotsiaalkapitali üksikute komponentide olemusest, alamliikidest, tekkemehhanismidest ja seostest, võimalustest sotsiaalkapitali sihipäraseks loomiseks majanduspoliitiliste meetmetega. Tabelid. Skeemid

  2. China on the eve of Copenhagen

    International Nuclear Information System (INIS)

    Niquet, V.

    2009-01-01

    The author first gives an overview of the Chinese worrying energy situation because of its high economic growth and its high energy demand and consumption. She highlights the preponderant share of coal and the associated environmental issues. She comments the economic and strategic implications of the oil share increase in energy consumption in China with respect to its energy supply security. She discusses the present debate on costs which would result from not taking environmental issues into account, and the weight of lobbies and local policies on these issues. Then, she notices that, however, significant evolutions can be observed in the Chinese environmental strategy: implemented policies and actions, research and development policy and investments. She discusses the consequences of these aspects and evolutions for the international negotiations in Copenhagen, and also the influence of the present economic and financial crisis on the Chinese environmental strategy

  3. Witches howl on New Year's Eve

    DEFF Research Database (Denmark)

    Grünbaum, Liselotte

    1997-01-01

    on the setting has to be picked up and contained both in the therapeutic relationship and in the network by teamwork, and b) by carefully following the child's movements in the transference relationship, the child can be helped to a dependent relationship inside which feelings can be made sense of....

  4. Tööstusomandi õiguskaitse / Eve Tang

    Index Scriptorium Estoniae

    Tang, Eve

    2005-01-01

    Nimestik Eesti tööstusomandi valdkonna õigusaktidest, Patendiameti ametlikest ja metoodilistest väljaannetest, on-line andmebaasidest. Lisatud tabel: Eesti Vabariigi ühinemine rahvusvaheliste lepingutega tööstusomandi valdkonnas

  5. Ryutaro - meie klassi jaapanlane / Eve Kukemelk

    Index Scriptorium Estoniae

    Kukemelk, Eve

    2011-01-01

    Tartu Miina Härma gümnaasiumis õppivast jaapani poisist Ryutaro Furukawa'st, kes tuli Eestisse koos oma eestlasest ema ja noorema vennaga pärast Fukushima tuumaelektrijaama katastroofi, maavärina ja tsunami üleelamist

  6. Multimeediaetendus : Opera Gets Plugged / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2008-01-01

    Eesti Muusika- ja Teatriakadeemia lühiooperite õhtul "Opera Gets Plugged" etendunud lavastustest - Monika Mattieseni "DMeeter" ja Age Hirve "Tuleloitsija": Mõlema lavastaja ja projektijuht Liis Kolle

  7. Noah and EVE (Environmental Values Education).

    Science.gov (United States)

    Knapp, Clifford

    1995-01-01

    Environmental ethics provide a set of related values that help to limit or restrict individual freedom in order to save and protect nature. Examples of environmental ethics include land ethics, deep ecology, social ecology, Native or first peoples' worldviews, reverence for life, and conservation and management. Includes teaching strategies and a…

  8. Aed: ajastatud = Garden: timed / Eve Komp

    Index Scriptorium Estoniae

    Komp, Eve, 1982-

    2013-01-01

    EKA arhitektuuri ja linnaplaneerimise osakonna III kursuse 2009-2012 aastail erialase projekteerimise raames loodud lahenduses on iga avalik ruum ümber raekoja hoone kujundatud erinevalt, vastavalt päeva rütmile

  9. Painting radioprotection at the nuclear eve

    International Nuclear Information System (INIS)

    Portelli, Aurelien; Travadel, Sebastien; Guarnieri, Franck; Parizel, Claire

    2017-01-01

    The CEA Marcoule centre is one of the first pillar of the French nuclear industry. The radiation protection department (SPR) of the centre benefited from the artistic skill of Jacques Castan who illustrated the safety campaigns of the SPR since 1959 and fed an imagination about radiation protection. His most ambitious creation was a wall painting in a staircase, made in 1962. This article describes the symbolic meaning of this work of art, which is today missing

  10. Koit rikkus hea ajakirjandustava / Eve Rohtla

    Index Scriptorium Estoniae

    Rohtla, Eve, 1961-

    2007-01-01

    Ilmunud ka: Kesknädal, 11. apr. 2007, lk. 5. Pressinõukogu arutas Heimar Lengi kaebust ajalehes Koit 8.02. 2007 avaldatud valimisreklaami peale ning otsustas, et ajaleht rikkus head ajakirjandustava. Heimar Lenk polnud rahul, et tema tekst ei sisaldanud märget "Tasutud tekst", kuigi ta oli selle avaldamise eest ajalehele maksnud. Samuti polnud ta rahul, et tema reklaamteksti kohal oli teda halvustav lugejakiri

  11. 19. II esitas HULA Kanuti gildi vaatemängulist kostüümidraamat

    Index Scriptorium Estoniae

    2003-01-01

    Rõivakollektsiooni autorid on HULA loojad Reet Ulfsak, Marit Ahven, Anu Lensment, Eve Hanson ning külalistena Ruta Tepp, Ketlin Bachmann. HB kollektsiooni jaoks disainitud ehete autorid on Tanel Veenre, Andrus Rumm, Julia-Maria Pihlak

  12. An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence from quartz inclusions in bricks

    DEFF Research Database (Denmark)

    Ramzaev, V.; Bøtter-Jensen, Lars; Thomsen, Kristina Jørkov

    2008-01-01

    . The area was significantly contaminated by Chernobyl fallout with initial (CS)-C-137 ground deposition level of similar to 1.1 MBq m(-2). The accumulated OSL doses in sections of the bricks varied from 141 to 207 mGy, of which between 76 and 146 mGy are attributable to Chernobyl fallout. Using the OSL...... depth-dose profiles obtained from the exposed bricks and the results from a gamma-ray-survey of the area, the Chernobyl-related cumulative gamma-ray dose for a point detector located in free air at a height of 1 m above the ground in the study area was estimated to be ca. 240 mGy for the time period...... starting on 27 April 1986 and ending on 31 July 2004. This result is in good agreement with the result of deterministic modelling of the cumulative gamma-ray dose in free air above undisturbed ground from the Chernobyl source in the Bryansk Region. Over the same time period, the external Chernobyl...

  13. Experimental setup for studying the effects of alpha particles on zebrafish embryos

    International Nuclear Information System (INIS)

    Yum, E.H.W.; Ng, C.K.M.; Lin, A.C.C.; Cheng, S.H.; Yu, K.N.

    2007-01-01

    In the present work, we have studied the feasibility to use an experimental setup based on polyallyldiglycol-carbonate (PADC) films to study effects of alpha particles on dechorionated zebrafish embryos. Thin PADC films with a thickness of 16 μm were prepared from commercially available CR-39 films by chemical etching and used as support substrates for holding zebrafish embryos for alpha-particle irradiation. These films recorded alpha-particle hit positions, quantified the number and energy of alpha particles actually incident on the embryo cells, and thus enabled the calculation of the dose absorbed by the embryo cells. Irradiation was made at 4 h post fertilization (hpf) with absorbed doses up to 2.3 mGy. Images of the embryos at 48 hpf were examined for identification of morphologic abnormalities. The preliminary results showed that absorbed doses corresponding to the abnormally developed embryos ranged from 0.41 to 2.3 mGy, which was equivalent to 0.21-1.2 mGy in human

  14. Reference dose levels for dental periapical radiography in Chonnam Province

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  15. CT measurements of torsion and length in the lower extremities

    International Nuclear Information System (INIS)

    Waidelich, H.A.; Strecker, W.; Schneider, E.

    1992-01-01

    Complex corrective osteotomies in the lower extremities require precise preoperative planning. Fifty patients who had suffered fractures of the lower limbs and had been treated by osteosynthetic or conservative methods were studied, using a GE 9800 Quick CT; accurate and reproducible measurements of the angles of torsion of the femur and tibia were obtained. Digital images were produced to standardise the planes of measurement and to measure the length of the limb. The most important clinical measurement is the intra-individual difference of the torsional angles. Amongst normals this is 4.3 ± 2.3deg in the femur and 6.1 ± 4.5deg in the tibia. Radiation exposure was measured by a LiF-thermoluminescence dosimeter on an Alderson phantom. Skin dose was 6.3 ± 1.2 mGy and gonadal dose for females was 2.5 ± 0.3 mGy and for males 0.7 ± 0.1 mGy. (orig./GDG) [de

  16. Reference dose levels for dental periapical radiography in Chonnam Province

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja [Department of Oral and Maxillofacial Radiology, College of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Lee, Jae Seo [Department of Oral and Maxillofacial Radiology, Chonnan National University Hospital, Gwangju (Korea, Republic of); Kim, Young Hee [Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Chuncheon (Korea, Republic of)

    2009-12-15

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  17. Study of the radiated energy loss during massive gas injection mitigated disruptions on EAST

    Science.gov (United States)

    Duan, Y. M.; Hao, Z. K.; Hu, L. Q.; Wang, L.; Xu, P.; Xu, L. Q.; Zhuang, H. D.; EAST Team

    2015-08-01

    The MGI mitigated disruption experiments were carried out on EAST with a new fast gas controlling valve in 2012. Different amounts of noble gas He or mixed gas of 99% He + 1% Ar are injected into plasma in current flat-top phase and current ramp-down phase separately. The initial results of MGI experiments are described. The MGI system and the radiation measurement system are briefly introduced. The characteristics of radiation distribution and radiation energy loss are analyzed. About 50% of the stored thermal energy Wdia is dissipated by radiation during the entire disruption process and the impurities of C and Li from the PFC play important roles to radiative energy loss. The amount of the gas can affect the pre-TQ phase. Strong poloidal asymmetry of radiation begins to appear in the CQ phase, which is possibly caused by the plasma configuration changes as a result of VDE. No toroidal radiation asymmetry is observed presently.

  18. Occupational radiation exposure in the GDR in 1977

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1977, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,348 persons), measurements with a whole-body counter (198 persons) and analyses of biosamples (174 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 253. In 6 cases the monthly exposure exceeded 30 mGy and the 9 highest annual exposure values were in the range of 50 to 120 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual radiation exposure was below one-tenth the maximum permissible dose. (author)

  19. Evolution of diagnostic reference levels in Spanish intraoral radiology

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, F.; Martinez-Beneyto, Y.; Alcaraz-Saura, M.; Velasco, E.; Achel, G. D.; Canteras, M.

    2008-01-01

    A total of 16 175 official reports of quality assurance on dental radiodiagnostic surgeries from 16 Spanish autonomous regions compiled during 2002-09 were studied to determine the evolution of diagnostic reference levels (DRLs) for obtaining a diagnostic image in the normal conditions of clinical practice in Spanish dental clinics. A DRL of 3.1 mGy was set in 2009, which represents a 35.4 % decrease compared with the dose determined in 2002 (4.8 mGy). During the same period, the mean dose fell by only 17.2 %. The DRL recommended by the European Union in 2004 for intraoral radiology is 4 mGy, and this study shows that 83.4 % of the installations used a dose below this. Of the installations using indirect or direct digital systems 1.1 and 1.2 %, respectively, used doses higher than those recommended, while 14.2 % of those using radiographic film exceeded this limit. (authors)

  20. Results of EPR dosimetry for population in the vicinity of the most contaminating radioactive fallout trace after the first nuclear test in the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Ivannikov, Alexander; Zhumadilov, Kassym; Tieliewuhan, Eldana

    2006-01-01

    The method of electron paramagnetic resonance (EPR) spectroscopy for tooth enamel is applied to individual radiation dose determination to residents of two villages (Dolon and Mostik) in the vicinity of the Semipalatinsk nuclear test site in Kazakhstan. These villages are located near the central axis of the radioactive fallout trace of the most contaminating surface nuclear test conducted in 1949. It is found that excess doses obtained by subtraction of natural background dose from dose absorbed in enamel range up to 440 mGy to residents of Dolon, whose enamel was formed before 1949, and do not exceed 120 mGy to younger residents. To residents of Mostik, excess doses do not exceed 100 mGy regardless of age except for one resident with an extremely high dose of 1.25 Gy. These results are in agreement with the pattern of radioactive contamination of the territory after the nuclear test of 1949 except one case of extremely high dose, which should be additionally investigated. (author)

  1. Experimental setup for studying the effects of alpha particles on zebrafish embryos

    Energy Technology Data Exchange (ETDEWEB)

    Yum, E.H.W.; Ng, C.K.M. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong (China); Lin, A.C.C.; Cheng, S.H. [Department of Biology and Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong (China); Yu, K.N. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong (China)], E-mail: peter.yu@cityu.edu.hk

    2007-11-15

    In the present work, we have studied the feasibility to use an experimental setup based on polyallyldiglycol-carbonate (PADC) films to study effects of alpha particles on dechorionated zebrafish embryos. Thin PADC films with a thickness of 16 {mu}m were prepared from commercially available CR-39 films by chemical etching and used as support substrates for holding zebrafish embryos for alpha-particle irradiation. These films recorded alpha-particle hit positions, quantified the number and energy of alpha particles actually incident on the embryo cells, and thus enabled the calculation of the dose absorbed by the embryo cells. Irradiation was made at 4 h post fertilization (hpf) with absorbed doses up to 2.3 mGy. Images of the embryos at 48 hpf were examined for identification of morphologic abnormalities. The preliminary results showed that absorbed doses corresponding to the abnormally developed embryos ranged from 0.41 to 2.3 mGy, which was equivalent to 0.21-1.2 mGy in human.

  2. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  3. Residual stress and its effect on the mechanical properties of Y-doped Mg alloy fabricated via back-pressure assisted equal channel angular pressing (ECAP-BP)

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Jianghua, E-mail: j_shen@live.cn [Department of Mechanical Engineering, University of North Carolina at Charlotte, Charlotte, NC 28223-0001 (United States); School of Aeronautics, Northwestern Polytechnical University, Xi’an 710072 (China); Gärtnerová, Viera [Laboratory of Nanostructures and Nanomaterials, Institute of Physics of the ASCR, Na Slovance 2, CZ – 182 21, Prague 8 (Czech Republic); Kecskes, Laszlo J. [US Army Research Laboratory, Aberdeen Proving Ground, MD 21005-5069 (United States); Kondoh, Katsuyoshi [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaragi, Osaka 567-0047 (Japan); Jäger, Aleš, E-mail: jager@fzu.cz [Laboratory of Nanostructures and Nanomaterials, Institute of Physics of the ASCR, Na Slovance 2, CZ – 182 21, Prague 8 (Czech Republic); Wei, Qiuming [Department of Mechanical Engineering, University of North Carolina at Charlotte, Charlotte, NC 28223-0001 (United States)

    2016-07-04

    In this study, pure magnesium (Mg) and Mg-0.6 wt% yttrium (Y) binary alloy were fabricated via casting followed by room temperature equal channel angular pressing (ECAP) using an applied back pressure (BP). Microstructural examination after ECAP-BP revealed a fine-grained Mg-Y alloy with a high residual stress level, whereas, the pure Mg exhibited a well-recrystallized microstructure with uniform and equiaxed grains, but retaining very little residual stress. The Y atoms were present in the Mg matrix as solid solutes and acted as dislocation and grain boundary blockers, thus suppressing dynamic recovery and/or recrystallization during the ECAP process. The Mg-Y alloy had an average grain size of ~400 nm, approximately one order smaller than that of pure Mg. The combination of high residual stress and ultrafine grains of the Mg-Y alloy gave rise to a significant difference in its mechanical behavior from that of the pure Mg, under both quasi-static and dynamic compressive loading.

  4. Kõik sõltub meist endist / Loit Jõekalda

    Index Scriptorium Estoniae

    Jõekalda, Loit

    2000-01-01

    VI rahvusvahelisest Läänemere maade graafikabiennaalist "Kaliningrad-Königsberg 2000". Grand prix - Juho Karjalainen, kolm võrdset preemiat - Virge Jõekalda, Redas Dirzys, Andrei Kostin (postuumselt). Diplomi saanud kunstnikud. Osalejad (žüriis Eve Kask) Eestist.

  5. "OUT" elab edasi / Mari Sobolev

    Index Scriptorium Estoniae

    Sobolev, Mari, 1968-

    1998-01-01

    "OUT'98". Kuraatorid Eve Kiiler, Piret Räni. Otsingutest videovallas (I. Helander, A. Nali, K. Sukmit, M. Laanemets, J. Zoova). Näidati ka Tokio vodeofestivalil hõbepreemia saanud R. Kelomehe videot "House". [þmobil]-galerii saatusest.

  6. Suur Teatriõhtu 2006 ehk Nike kliendikaardiga Vanapaganast, Eurovisioonile pääsenud vaeslapsest, roosades rõivastes printsist ja paljust muust

    Index Scriptorium Estoniae

    2006-01-01

    Kuressaare Gümnaasiumi Suurest Teatriõhtust. Ürituse üle mõtisklevad žürii liige Aarne Mägi, vilistlane Mihkel Miller, peakorraldaja Eve Paomees ja teatriõhtu traditsiooni looja ja ürituse peakorraldaja Marit Tarkin

  7. Saddam ootab hukkamist / Aadu Hiietamm

    Index Scriptorium Estoniae

    Hiietamm, Aadu, 1954-

    2006-01-01

    Apellatsioonikohus kinnitas endisele Iraagi diktaatorile Saddam Husseinile määratud surmaotsuse, andes selle täideviimiseks aega 30 päeva. Vt. samas: Eve Heinla, Urmo Soonvald. Ansip ja Paet: Eesti austab Iraagi kohtu otsust

  8. Conspicuous by Its Absence

    Institute of Scientific and Technical Information of China (English)

    JOSEPH; KIRSCHKE

    2010-01-01

    This year, I’m told, was a bit different:in the interest of not insulting millions of struggling Americans, Santa andhis reindeer touched down very lightly in the United States last month. New Year’sEve,

  9. Eesti Post sukeldub kiirlaenuärisse / Dannar Leitmaa

    Index Scriptorium Estoniae

    Leitmaa, Dannar, 1982-

    2008-01-01

    Eesti Post pakub katseprojekti raames isikusamasuse tuvastamise teenust viiele kiirlaenu pakkuvale firmale. Parlamendiliikmete Indrek Raudse ja Evelyn Sepa ning Tallinna Sotsiaaltöökeskuse sotsiaalteenuste osakonna juhataja Eve Võrgu kommentaarid. Lisa: Ministeerium: kõik on seaduslik

  10. Diagnosis value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Ma Zhoupeng; Zhou Jianjun; Liu Xueling; Wang Chun; Zhang Shunzhuang

    2012-01-01

    Objective: To explore the diagnostic value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma. Methods: Sixty patients who were suspected of clear cell renal cell carcinoma underwent non-enhanced CT and contrast enhancement CT of early interface-phase between cortex -medulla and parenchymal phase on a dual-energy CT. The true non-enhanced kidney CT (TNCT) was performed in a single-energy acquisition mode, but the dual-phase contrast enhancement CT were performed in a dual-energy mode of 80 kV and 140 kV respectively. The virtual non-enhanced CT (VNCT) images were derived from the data of early interface phase using liver virtual non-contrast software. The diagnose according to VNCT combined dual-phase contrast enhancement CT and dual-phase contrast enhancement CT only were made respectively and compared with χ 2 test. Between the true non-contrast CT and the virtual non-contrast CT, the image quality was compared with Wilcoxon test; The radiation dose of volume CT dose index (CTDIvol) and dose length product(DLP) in a single-phase and total examination, the mean CT HU values of the tumours were compared with t test. Results: The accuracy of VNCT combined dual-phase contrast enhancement CT was higher than that of dual-phase contrast enhancement CT only [93.3% (56/60) vs.78.3% (47/60); χ 2 =5.6, P<0.05]. The detective ability (score) of VNCT was near to that of TNCT and the difference was not obvious (Z=0.00, P>0.05). The radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination of VNCT [(8.85 ± 1.28) mGy, (196.45 ±21.12) mGy·cm, (17.69±2.35) mGy, (392.90±42.25) mGy · cm] were lower than that of TNCT [(10.20 ± 1.44) mGy,(218.29 ± 29.60) mGy · cm, (30.61 ± 3.27) mGy and (654.86 ± 88.81) mGy ·cm], t=4.21, 3.58, 23.63, 16.12 respectively, P<0.05. The mean CT HU values of tumours on VNCT images was higher than that

  11. Patient dosimetry and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Suliman, I. I.

    2007-08-01

    In the first part of the study, entrance surface doses (ESDs) to patients in radiography were estimated from x-ray tube output parameters for a sample of 346 radiographs. The mean ESDs estimated in the hospitals ranged from 0.17 to 0.27 mGy for chest PA, 1.04-2.26 mGy for skull AP/PA, 0.83-1.32 mGy for skull LAT, 1.31-1.89 mGy for pelvis AP, 1.46-3.33 mGy for Lumbar Spine AP and 2.9-9.9 mGy for Lumbar Spine LAT. With the exception of chest PA examination at two hospitals, mean ESDs were found to be within the established international reference doses. In addition, study was performed to compare two methods used for effective dose calculation in diagnostic radiology. Initially, ED values were calculated from ESD values using NRPB-SR262 Monte Carlo data and XDOSE software. Next, the energy imparted to patients was computed using values for entrance skin exposure-area product and half-value layer. Effective doses were then determined from energy imparted using ED/ε conversion factors proposed in the literature. Mean ED values calculated using the two methods were: 21.3-23.4, 14.1-12.8, 7.9-8.5, 232-226, 215-223 and 91-85.6 μSv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. The values obtained were in agreement between themselves and with data reported in the literature. In the second part, a protocol for quality control (QC) tests has been drafted based on various national and international recommendations. Tests were included for various parts of the imaging chain, i.e. x-ray tube and generator; x-ray tube control system; laser printer and display station; image quality and patient dose. Preliminary tolerance levels have been set for the various tests, after initial measurements. To check the suitability of the QC tests and the stated tolerance levels, measurements were made at the University Hospital Gasthuisberg in Leuven, the Netherland, for equipment used for paediatric radiology and a unit used

  12. Disruption mitigation experiment with massive gas injection of HT-7

    International Nuclear Information System (INIS)

    Zhuang Huidong; Zhang Xiaodong

    2013-01-01

    Massive gas injection (MGI) is a promising method on disruption mitigation. The working principle of the fast valve for disruption mitigation was introduced. The disruption mitigation experiments by MGI on HT-7 were described. The experiment shows that the impurities radiation is improved by injecting appropriate amount of gas, and the current quench rate is slow down, so the electromagnetic load on the device is mitigated. The experiments show that the fast valve can completely satisfy the requirement of disruption mitigation on HT-7. (authors)

  13. Risk and benefit associated with preventive mammography examinations

    International Nuclear Information System (INIS)

    Vladar, M.; Nikodemova, D.

    1998-01-01

    The risk of mammographic examination was estimated. It is concluded that a mean glandular dose (MGD) of 1 mGy per exposure can be associated with a risk of 1 radiation-induced carcinoma per less than 100 positive detected by the preventive examination. The variability of actual MGD at various hospitals can be quite large. Although the majority of measurements were made on phantoms it is assumed that the national MGD average will exceed 3 mGy for the average breast size of 55 mm

  14. "Impact 4" Berliinis ja Poznanis / Vappu Thurlow

    Index Scriptorium Estoniae

    Thurlow, Vappu, 1960-

    2005-01-01

    5.-10. IX Berliinis ja Poznanis toimunud neljandast rahvusvahelisest graafikakonverentsist "Impact" alapealkirjaga "Kontakt". Eestist osalesid Loit Jõekalda, Eve Kask, Karin Laansoo ja Vappu Thurlow. 2007. a. Tallinnas toimuva "Impact 5", alapealkirjaga "Slices of Time/Lõigutud aeg", kontseptsioon

  15. Triennaali peaauhind läks Leetu

    Index Scriptorium Estoniae

    2004-01-01

    Tallinna XIII graafikatriennaalil väljaantud preemiad: peaauhind - leedu graafik Egle Kuckaite, diplomid - eesti kunstirühmitus John Smith (projekt betoonkohvritega "100 John Smithi") ja Eve Kiiler (fotoseeria "Fantastiline realism"), kiituskiri - eesti rühmitus Anonymous Boh

  16. 20. VI avatakse EKA galeriis rahvusvaheline fotonäitus "Fragile Distance"

    Index Scriptorium Estoniae

    2003-01-01

    Kuraatorid David Bate, Eve Kiiler. Osalevad Londonis elavad ja töötavad fotograafid Denny Robson, Adam Green, Michelle Atherton (Inglismaa), Eva Riegler (Austria), Andreas Hablutzel (Šveits), Angeliki Douveri, Stella Baraklianou (Kreeka), Simona Dell'Agli (Itaalia)

  17. Põhjamaade ehtekunst

    Index Scriptorium Estoniae

    2002-01-01

    Tarbekunstimuuseumis II Põhjamaade ehtekunsti triennaal. Kujundaja Castello Hansen. Eesti ehtekunsti esindavad Piret Hirv, Eve Margus Villems, Maria Valdma, valiku pani kokku Kadri Mälk. Uuenduseks ühe klassiku, rootsi kunstniku Torun Bülow Hübe loomingu eksponeerimine

  18. Milline on edukas teatri ja lavastuste kommunikatsioon? / Piret Jaaks

    Index Scriptorium Estoniae

    Jaaks, Piret, 1980-

    2015-01-01

    Kommunikatsioonist Eesti teatrites. Kogemusi jagavad Kristo Kruusman Rakvere teatrist, Kätlin Sumberg Teatrist NO99, Ruudu Raudsepp Linnateatrist, Eveli Loorents Endla teatrist, Hannele Känd Nukuteatrist, Herkko Labi Von Krahli teatrist ja väiketeater Cabaret Rhizome

  19. A completed audit cycle of the lateral scan projection radiograph in CT pulmonary angiography (CTPA); the impact on scan length and radiation dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2013-01-01

    Aim: To investigate the effect of incorporating a lateral scan projection radiograph (topogram) in addition to the standard frontal topogram on excess scan length in computed tomography pulmonary angiography (CTPA) and to quantify the impact on effective dose. Materials and methods: Fifty consecutive patients referred for exclusion of pulmonary embolism who had undergone a CTPA examination with conventional frontal topogram to plan scan length (protocol A) were compared with 50 consecutive patients who had undergone a CTPA study with frontal and additional lateral topogram for planning (protocol B) in a retrospective audit. Optimal scan length was defined from lung apex to lung base. Mean excess scan length beyond these landmarks was determined. The mean organ doses to the thyroid, liver, and stomach, as well as mean effective dose, were estimated using standard conversion factors. Results: The mean excess scan length was significantly lower in protocol B compared to the protocol A cohort (19.5 ± 17.4 mm [mean ± standard deviation] versus 39.1 ± 20.4 mm, p < 0.0001). The mean excess scan length below the lung bases was significantly lower in the protocol B cohort compared to the protocol A group (7.5 ± 12.7 mm versus 23 ± 16.6 mm, p < 0.0001), as were the mean organ doses to the stomach (4.24 ± 0.81 mGy versus 5.22 ± 1.06 mGy, p < 0.0001) and liver (5.60 ± 0.64 mGy versus 6.38 ± 0.81 mGy, p < 0.0001). A non-significant reduction in over-scanning above the apices in protocol B was observed compared with protocol A (12 ± 8.8 mm versus 16.2 ± 13.6 mm, p = 0.07), which equated to lower mean thyroid organ dose in (3.28 ± 1.76 mGy versus 4.11 ± 3.11 mGy, p = 0.104). Conclusion: The present audit indicates that incorporation of a lateral topogram into the CTPA protocol, together with radiographer education, reduces excess scan length, which significantly reduces the dose to the liver and stomach, and potentially lowers the dose to the thyroid. This simple

  20. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination.

    Science.gov (United States)

    McKnight, Colin D; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H; Parmar, Hemant A

    2014-08-01

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDIvol) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDIvol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDIvol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDIvol in the ASIR group (P ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of